Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
37941-Z
gUFFOI,r Town of Southold Annex 2/14/2014 P.O.Box 1179 y = 54375 Main Road oy Southold,New York 11971 0 CERTIFICATE OF OCCUPANCY No: 36766 Date: 2/14/2014 THIS CERTIFIES that the building WIRELESS COMMUNICATION SYSTEMS Location of Property: 23300 Route 25, Orient, SCTM#: 473889 Sec/Block/Lot: 18.-5-13.8 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this ofliced dated 1/24/2013 pursuant to which Building Permit No. 37941 dated 4/16/2013 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: modify an existing wireless facility for AT&T/New Cingular as applied for The certificate is issued to Orient Fire District (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 37941 10/7/13 PLUMBERS CERTIFICATION DATED rize Si ure TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE o . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 37941 Date: 4/16/2013 Permission is hereby granted to: Orient Fire District 23300 Route 25 Orient, NY 11957 To: Modify an existing wireless facility as applied for; certification of installation required, including replacement of missing panels, prior to C.O. At premises located at: 23300 Route 25, Orient SCTM # 473889 Sec/Block/Lot# 18.-5-13.8 Pursuant to application dated 1/24/2013 and approved by the Building Inspector. To expire on 10/16/2014. Fees: WIRELESS COMMUNICATIONS -MODIFICATIONS $500.00 CO -ACCESSORY BUILDING $50.00 Total: $550.00 Building Inspector I Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9,1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00,Additions to dwelling$25.00,Alterations to dwelling$25.00, Swimming pool$25.00,Accessory building$25.00,Additions to accessory building$25.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25' 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date.` f f:;t. c1! *Upgrade/Modification to existing public utility wireless telecommunications facility New Construction: X* Old or Pre-existing Building: (check one) Location of Property: 23300 Main Road Orient House No. Street Hamlet Owner or Owners of Property: Orient Fire District Suffolk County Tax Map No 1000,Section 18 Block 5 Lot 13.8 Subdivision Filed Map. Lot: Permit No. 3 Date of Permit. {& 1 Applicant:New Cingular Wireless PCS,LLC("AT&T") Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted:$ 50.00 New Cin ar 1 s PCS,LLC B ftfli6ant Signature Doug Hall,President of Shore 2 Shore Wireless,Inc., Agent for Applicant *pF SO�jyolo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 C iQ roger.riche rKb-town.southo Id.ny.us Southold,NY 11971-0959 r0UNT1,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: AT&T Address: 23300 Main Rd-rt-25 City: Orient St: NY Zip: 11957 Building Permit#: 37941 Section: 18 Block: 5 Lot: 13.8 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: JA Lee Electric Inc License No: 4236-me SITE DETAILS Office Use Only Residential Indoor Basement Service Only Commerical X Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 1-1 Twist Lock El Exit Fixtures TVSS Other Equipment: install low voltage 24volt to 48volt power converter inside existing DC power cabinet with connection to 3 remote radio heads(antennas) Notes: Inspector Signature: ZDate: Oct 7 2013 81-Cert Electrical Compliance Form.xls pE SOUT�o coulm,Nc� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH P G. [ ] FOUNDATION 2ND [ ] IN ATION [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: d4- 4n�==Cerl) 4 I DATE INSPECTOR 100 Paragon Drive Montvale,NJ 07643 Tel: (201)571-0730 Fax: (201)5710650 February 6, 2014 Town of Southold Building Department Town Hall 54375 Route 25 Southold, NY 11971 Subject: Professional Engineer's Certification Letter AT&T Site ID#: NYCENY0735 AT&T USID#: 46753 AT&T Site Name: Orient Point Fire Dept. Permit No: 37941 Section, Block& Lot: 18,5, 13.8 23300 Route 25, Orient, NY 11957 Latitude: N 41°08' 33"; Longitude: W 72° 17' 58" Dear Sir: This letter is to certify that Bechtel Associates Professional Corporation visited the AT&T telecommunications facility located at 23300 Route 25,Orient, NY 11957 on November 14, 2013; on behalf of AT&T,for the purpose of closing out documentation for LTE Building Permit#37941 and to certify that the existing construction/facility conforms to the Building Permit and the Town approved Construction Drawings(T01 through E04 Rev. 1, dated January 10,2013),with minor deviations as follows: Installed (1) radio head per sector. At the time of the inspection all panels were in place on the existing wireless communication pole. The facility as installed conforms with all applicable Town and New York State Building Codes. OF NEW Y p.PO M .CO 0 Respectfully submitted by Qj * Q cr- r— w Richard M.Coad, P.E. 04543g'� NY License#045439-1 AROFFgS\OAP Bechtel Associates Professional Corporation FIELD REPORT DATE CommNTS FOUNDATrON(1ST) Z FOUNDATION(ZND) W ROUGH FRAMUCF& o PLUIVIBING INSUL•ATION PEP,N.Y. 2D H STATE ENERGY CORE ' , 4 FINAL . G ADDITIONAL COMMENTS z . M 0 e Tb�N OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 Planning Board approval FAX: (631)765-9502 ?J 7. Survey SoutholdTown.NorthFork.net. PERNIIT NO. ' Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined 20_0_ Storm-Water Assessment Form Contact: Attorney for Applicant:. Approved 1�. 20 J3 Mail to: Re,Nielsen,Huber&Coughlin,LLP Disapproved a/c5j&1\ -I f i(�- 36 N.New York Ave.,Huntington,NY 11743 II ,L Phone: 631-425-4100 Expiration /0 1/6 20 7 Building Inspector APPLICATION FOR BUILDING PERMIT Datd ' o�L 20 3 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be,commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shal I be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. New Cingular Wireless PCS,LLC (Signature of applicant or name,if a Limited Liability ompany 1444 E.Jericho Tpke.,Huntington,NY 11743 (Mailing address of applicant) State whether applicant is owner,lessee, agent,architect,engineer,general contractor, electrician,plumber or builder Applicant is Lessee Name of owner of premises Orient Fire District T� ��'���� limited liability,com any (As on the tax roll or latest deed) Newp gult' a igna ure of duly authorized officer B . (Nam and title Doug Hall,President of Shore 2 ore Wireless, nc.,Agent for Applicant Builders License No. Plumbers.License No. N/A Electricians License No. Other Trade's License No. l. Location of land on which proposed work will be done: 23300 Main Road Orient House Number Street Hamlet County Tax Map No. 1000 Section 18 Block 5 Lot 13.8 Subdivision Filed lViap No. y�"fe;��' rJ�►�; �da,;i/i:P� "6f�r8ty`.1� -•r�t;i�IK�i r' tntrst' ► rr?:oom;01` Mi lid+tli9k`:t%�w 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Fire House,Public Safety and Public utility wireless telecommunications facility b. Intended use and occupancy Public Utility Wireless Telecommunications Facility 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal - . Demolition "Other Work Lessee/Applicant propose to modify/upgrade its exising public utility wireless telecommunications facility as depicted in the plans submitted herewith. (Description) 4. Estimated Cost gZ<-To o 2 G r� Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units N/A Number.of dwelling units on each floor If garage, number of cars -Fire House,Public Safety and Public utility wireless 6. If business, commercial or mixed occupancy,specify nature and extent of each type of usetelecommunications facility-- 7. Dimensions of existing structures,if any:Front Rear Depth Height. Number&Stories *Existing 90'monopole a #Nc u cl ng G le-f k1?rtleSS 6el5H M� Q ,Pv►Ie 04 2rCG IU ' k ZZ'-z 1 / Dimensions of same structure with alterations or additions: Front Rear F Depth Height Number of Stories *No change Sr,-�'►��a s a-h c v� S. Dimensions of entire new construction:Front Rear Depth Height Number of Stories Ste,e a S a �c v ! 189,8.16 sq.ft. • 9. Size of lot: Front . Rear Depth 10.Date of Purchase Nov. 14, 1 885, Name of Former Owner • Barbara Dwight Schriever 11.Zone or use district in which premises are situated Residential R-80 12.Does proposed construction violate any zoning law,ordinance or regulation?YES �NO X. 13. Will Iot be re-graded?YES NO X Will excess fill be removed from premises?YES ' NO X 23300 Main Road 14.Names of Owner.of premises Orient Fire District Address Orient,NY Phone No. 31-3 Z 2-4 L(5 27�5 [s`tVlew iTnre Name of Architect►, I ASSGcIQ+� Pco lnn&l C 11�wadress reaPn� nn '7o _ _Phone NoZol-S'71-073 Name of ContractorgecliteI ccwTi ,10--hcv.6,_►wc. Address ieofrrca cn Vnv�,su�ki�PhoneNo.�Qi_57J-�/ °) �Ma,)i-vc 1e14NJ 07(o4S 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES . NO x *IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C.PERMITS MAY BE REQUIRED. b. Is this property.within 300 feet of a tidal wetland?* YES NO x * IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?* YES X NO * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF�A Doug Hall being dilly sworn,deposes and says that(s)he is the;jR& k (Name of individual signing contract)above named, gis^:td�e President of Shore 2 Shore Wireless,Inc.,Agent for Applicant-New Cingular Wireless PCS,LLC, Lessee (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work mill be performed in the manner set forth in the application filed therewith. Sworn t before the this 2 day of / 4O1NuA 20 J New Cingular Wireless PCS,LLC • By" Notary Public S gnature o pplicant Patrick S. O'Rour> a Doug Hall President of Shore 2 Shore Wireless,Inc.,Agent for Applicant Notary Public utete of New York- Print Name!Title above No.-011OR6152094 Quplified.in NassaN County Commision Expires Dec. 5,24ff FOR INTERNAL.USE ONLY SITE PLAN USE DETERI�IilNA1`ION Initial Determination �� I Date Sent:___l___ L� l Date: —� - Project Name: r: Project Address: - , Zoning District: L � Suffolk County Tax Map.No.:1000-� — Request: (Note: Copy.of Building Permit App lication and supporting documentation'as to . Proposed use or uses should be submitted.) -Initial Determination as to whether use is permitted: s Initial Determination as to whether site plan is required: Signature o�Build�lnglnspector���' Planning Department (P.D.) Referral: P.D.'Date Received: / /-- Date of Comment: i�---r Comments: Signature of Planning Dept.-Staff Reviewer Final Determination Date: I 1 Decision: Rian' wrP of Rtiildinv InsnPctnr FOR INTERNAL.USE ONLY t �� AN USE DETERMINATION SITE PLAN ,. lnitial petermination • Date Sent: _f /-1- Date: 1 Eric J_ -- Project Name: r: Project Address: 5 1000= - S - zoning District: Suffolk County Tax Map No.. ---- RequQst: n and supporting documentation a$ to (Note: COPY.of Building Permit App licatio proposed use or uses should be submitted.). Initial Determination as to whether use is.p ermitted: ,. Initial Determination as to whether site plan is required: Signature of Building Inspector Planning Department (P.D.) Referral: / o / ! Date of Comment: —.�.._-- P.D. Date Received _ — Comments: 2 _ ... signature of Planningy'Dept• Staff viewer �y. E C E W E Final Determination pate: 1_ - APR 12 2013 Decision: TOWN OF SOUTHOLD ...__ _,r otatirtinn InsnPctor ` MAILING ADDRESS: w� :'-PLANNING BOARD MEMBE..— P.O.Box 1179 JERILYN B.WOODHOUSE `��F sOuTjyO! Southold,NY 11971 Chair, O OFFICE LOCA17ON: KENNETH L.EDWARDS Town Hall Annex MARTIN H.SIDOR us ys 54375 State Route 25 GEORGE D.SOLOMON un (cor.Main Rd. &Youngs Ave.) JOSEPH L.TOWNSEND OI�Co�' Southold,NY& Telephone:631 765.1938 Fax:.631 765-3136 PLANNING BOARD OFFICE TOWN OF SOUTHOLD June 13, 2006 Lawrence C. R6 Munley, Meade, Nielsen & Re 36 North New York Avenue Huntington, NY 11743 Re: Proposed Site Plan for Orient FD Telecom Located on the s/s/o Main Road at the s/e intersection of Main Road and Tabor Road in Orient. SCTM#1000-18-5-13.8 Zoning District: R-80 Dear Mr. R& The Southold Town Planning Board, at a meeting held on Monday, June12, 2006, adopted the following resolutions: The final public hearing was closed. WHEREAS, the site plan is for the co-location of Nextel @ 85' height, Cingular @ 75' height &Verizon @ 65' height on a proposed 90' communications flagpole tower with fire/police emergency communication mounted on a cross bar @ 90' height and includes a 43'x46'x 6' high fenced enclosure on a 4.4-acre parcel in the R-80 Zone located on the s/s/o Main Road at the s/e intersection of Main Road and Tabor Road in Orient. SCTM# 1000=18-5-13.8; and WHEREAS, Orient Fire District is the owner of the property located on the s/s/o Main Road at the s/e intersection on Main Road and Tabor Road in Orient; and WHEREAS, on March 31, 2005, the Southold Town Zoning Board of Appeals granted a Variance described under Appeal Number 5408 allowing the construction of a 90,ft. wireless communications flagpole and related equipment enclosure; and WHEREAS, on November 9, 2005, the agent, Lawrence C. R6, working for New Cingular Wireless PCS, LLC, submitted an amended formal site plan for approval; and WHEREAS, on November 18, 2005, the New York State Department of Transportation responded after review and determined a permit would not be necessary as long as all work is out of the State ROW; and MAILING ADDRESS: PLANNING BOARD MEMBERS ��,``OF S��T P.O.Box 1179 DONALD J.WILCENSKI O k Ql Southold,NY 11971 Chair h OFFICE LOCATION: WILLIAM J.CREMERS Town Hall Annex PIERCE RAFFERTY G Q 54375 State Route 25 JAMES H.RICH III �� O (cor.Main Rd. &Youngs Ave.) MARTIN H.SIDOR �y100u ,� Southold,NY Telephone: 631 765-1938 Fax: 631 765-3136 PLANNING BOARD OFFICE TOWN OF SOUTHOLD MEMORANDUM To: Michael J.Verity, Chief Building Inspector From: Heather M. Lanza,AICP, Planninector ALg 'r Date: April 12, 2013 Re: Planning Department Report AT&T/New Cingular Wireless LTE modifications and upgrades S CTM#1000-18.-5-13.8 23300 NYS Rt. 25, Orient As an addendum to the'attached SPUD, the Planning Department has conducted a review of the proposed LTE modifications pursuant to §280-74 B.(2), and has received a report from our wireless technical consultant, Cityscape, Inc. (see attached report)We have the following recommendations for this application: - 1. The proposed LTE modifications and upgrades are in compliance with the General Requirements of§280-70, therefore we recommend a building permit be issued for this application consistent with the construction drawings dated January 10, 2013. 2. The monopole currently exists with missing panels/sections following Hurricane Sandy; these panels must be replaced before a Certificate of Occupancy is issued. Thank you for your cooperation. MAILING ADDRESS: PLANNING ALB BOARD ME S MBERS �� y0 P.O.Box 1179 J.WILCENSKI �F DU� Southold,NY 11971 Chair OFFICE LOCATION: WILLIAM J.CREMERS Town Hall Annex PIERCE RAFFERTY G Q 54375 State Route 25 JAMES H.RICH III • �O (cor.Main Rd. &Youngs Ave.) MARTIN H.SIDOR �i OOUNT`1, Southold, NY � Telephone: 631.765-1938 Fax: 631 765-3136 - - — -. — PLANNING BOARD OFFICE TOWN OF SOUTHOLD l � FEB L l., 2014 MEMORANDUM BLDG. DFPT. TOUs'PJ OF,QOUTNOI D To: Michael J. Verity, Chief Building Inspector From: Heather M. Lanza, AICP, Planning Director�n�'' Date: February 14, 2014 Re: Planning Department Report AT&T/New Cingular Wireless LTE Modifications and Up-grades SCTM#1000-18-5-13.8 23000 NYS Rt. 25, Orient The Planning Department, together with the Town's Wireless Technical Consultant, Cityscape, Inc.,. conducted a final site inspection of the LTE modifications referenced above on January 29, 2014. Based on that site inspection, we have received a report from our consultant stating that all changes and modifications have been constructed in accordance with the provided construction drawings. We have found that the LTE modifications and up-grades are in compliance with the General Requirements of§280-70, therefore, we recommend a Certificate of Occupancy be issued for this application. Thank you for your cooperation. Orient FD Telecom Project Page Two June 13, 2006 WHEREAS, on November 21, 2005, the Orient Fire District responded that no additional requirements and/or recommendations for fire access are necessary; and WHEREAS, on November 28, 2005, the Suffolk County Department of Planning responded after review and determined this matter is for"local determination as there appears to be no significant county-wide or inter-community impact(s)" and the Planning Board accepts this pursuant to 239L & M General Municipal Law; and WHEREAS, on December 1, 2005, the Architectural Review Committee reviewed the architectural drawings and associated site plan materials and tabled the application pending the receipt of further information; and WHEREAS, on January 12, 2006, the Architectural Review Committee reviewed the architectural drawings and associated site plan materials and made recommendations; and WHEREAS, on April 13, 2006, the Southold Town Zoning Board of Appeals, under previous Appeal number 5408, granted a Variance described under Appeal Number 5863 allowing the relocation of the communications flagpole and related equipment enclosure; and WHEREAS, on April 13, 2006, the Southold Town Zoning Board of Appeals granted a Variance described under Appeal Number 5805 for public utility antennas and telecommunications use; and WHEREAS, on May 30, 2006, the Southold Town Building Inspector reviewed and certified the amended site plan for a "Wireless Communication Facility on an Existing Telecommunications Tower" use; and WHEREAS;on May 31, 2006, the Southold Town Engineer reviewed the amended site plan materials regarding the relocation of the wireless communications tower and related equipment enclosures and requested further information; and WHEREAS, on June 1, 2006, the Architectural Review Committee reviewed the revised architectural drawings and associated site plan materials and approved the application subject.to conditions, and, subject to their approval, the Planning Board incorporates this recommendation in the site plan; and WHEREAS, on June 12, 2006, the Southold Town Engineer reviewed the amended site plan materials and approved the drainage of existing conditions along with the proposed construction subject to comments/conditions and the Southold Town Planning Board incorporates such comments /conditions as requirements in this approval; and WHEREAS, the Southold Town Planning Board, pursuant to Chapter 58, Notice of Public Hearing, has received affidavits that the applicant has complied with the notification provisions; and Orient FD Telecom Project Page Three June 13, 2006 WHEREAS, the following items shall be required: 1. All outdoor lighting shall be shielded so that the light source is not visible from adjacent properties and roadways. Lighting fixtures shall focus and direct the light in such a manner as to contain the light and glare within property boundaries. The lighting must meet town code requirements. 2. All signs shall meet Southold Town Zoning Codes and shall be subject to approval of the Southold Town Building Inspector. 3. As per the landscape survivability guarantee, the applicant agrees to replace any of the landscaping which dies within three (3) years of planting; be it therefore RESOLVED that, on June 12, 2006, the Southold Town Planning Board, acting under the State Environmental Quality Review Act (6 NYCRR), Part 617.5 c (11&13), makes a determination that the proposed action is a Type II and not subject to review; and be it further RESOLVED, that the Southold Town Planning Board has reviewed the proposed action under the policies of the Town of Southold Local Waterfront Revitalization Program and has determined that the action is consistent provided that the best management practices outlined in the December 23, 2005 memo prepared by the LWRP Coordinator are implemented; and be it further RESOLVED, that pursuant to Southold Town Code 100-254 Part I, the applicant agrees to incorporate all the requirements, comments, and recommendations of each reviewing agency as referenced above and as indicated on the site plan and corresponding attachments; and be it further RESOLVED, that the Southold Town Planning Board grant approval on the site plan drawings T-1, A-1 &A-2 prepared by Michael Walker Design/Builder, LLC and certified by Michael Walker, Architect dated December 6,'2004 and last revised March 6, 2006 and authorize the Chairperson to endorse the site plans with the following conditions: 1. The site plan approval requires that all work proposed on the site plan shall be completed within three (3) years from the date of this resolution. 2. Prior to the request for the Certificate of Occupancy, the owner or authorized agent must request the said Building Inspector and the Planning Board to perform an on-site inspection to find the site improvements are in conformity with the approved amended site plan. 3. If the as-built site improvements vary from the approved amended site plan, the Planning Board reserves the right to request a certified as-built site plan detailing all the changes. Orient FD Telecom Project Page Four June 13, 2006 4. Any changes from the approved amended site plan shall require Planning Board .approval, and any such changes without Planning Board approval will be subject to referral to the Town Attorney's Office for possible legal action. The Planning Board will issue a final site plan approval in the form of a letter following a site inspection and at the time the site improvements are found to be in conformance with the approved site-plan. A copy of the approved amended site plan is enclosed for your records. As per the Town Code, one copy each will be distributed to the Building Department, Zoning Board of Appeals and Town Engineer/Highway Department. If you have any questions regarding the above, please contact this office. Very truly yours, , &rdlynB. Woodhouse Chairperson Enc. cc: Southold Town Zoning Board of Appeals Southold Town Building Department Southold Town Engineer Suffolk County Planning Department New York State Department of Transportation File APPEALS BOARD MEMBERS Mailing Address: Ruth D.Oliva,Chairwoman �O��O�so Mailing - Southold Town Hail 53095 Main Road•P.O. Box 1179 Gerard P.Goehringer 4 Southold,NY 11971-0959 James Dinizio,Jr. rn Office.Location: Michael A.Simon O Town Annex/First Floor,North Fork Bank Leslie Kanes Weisman �'YCQU01 54375 Main Road(at Youngs Avenue) Southold,NY 11971 http://southoldtown.northfork.net RECE1�icD� . ZONING BOARD OF APPEALS TOWN OF SOUTHOLD Tel.(631)765-1809-Fax(631)765-9064. MAY 2 3 2006 N AND DETERMINATION FININGS, DELIBERATIONS MEETING OF APRIL 13,2006 Appl. No.5805—CINGULAR WIRELESS; NEXTEL;VERIZON WIRELESS (Co-Applicants) Zone District: R-80 Residential Property Location: 23300 Main Road(State Route 25)and Tabor Road,Orient CTM 1000-18-5.13.8 SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions,without an adverse effect on the environment if the project is Implemented as planned. PROPERTY FACTS/DESCRIPTION: The applicant's property consists of 4.355 acres, situated on the south side of the Main Road (NYS Route 25) and the east side of Tabor Road in Orient. The property Is Improved with the following buildings and structures: (a) fire station with an existing antenna facility and(b)detached metal building. BASIS OF APPLICATION: Zoning Code Section 100-162A, and the Building Department's March 14, 2006 Notice of Disapproval, which states the applicants' proposal requires a Special Exception from the Southold Town Zoning Board of Appeals (and site approval from the Southold Town Planning Board). CODE PROVISIONS: - TELECOMMUNICATION TOWER, -- A telecommunication tower is a type of wireless communication facility designed and constructed specifically to support an antenna array, and may include a monopole, self-supporting tower, guy-wire support tower and other similar structures. A wireless communication facility attached to.an existing building or structure shall be excluded from this definition. [Added 11-12-1997 by L.L. No.26-19971 WIRELESS COMMUNICATION FACILITY -- Any unstaffed facility for the transmission and/or reception of wireless telecommunications services or other radio transmission and/or receiving service or use usually consisting of a wireless communication facility array, connection cables, an equipment facility and a support structure to obtain the necessary elevation. The support structure Is either a building, telecommunication or radio antenna or tower or other approved structure. [Added 11-12-1997 by L.L. No. 26- 1997; amended 2.2-1999 by L.L. No. 3-19991 Page 2—April 13,2006 • Appl.No.5805—Cingular,Nextel,Verizon 18.4-13.8 at Orient FINDINGS OF FACT The Zoning Board of Appeals held a public hearing on this application on March 2, 2006 and March 30, 2006,at which time written and oral evidence were presented. Based upon all testimony, documentation, personal inspection of the property, and other evidence,the Zoning Board finds the following facts to be true and relevant: APPLICANTS' REQUEST: The Applicants are seeking to Install a public utility wireless telecommunications facility at the premises by affixing wireless telecommunications antennas within an approved pole to be built, and to install related equipment as required to be functional. RELATED INFORMATION: The owner of the property,the'Orient Fire District(OFD), has a current building permit (the first having been issued June 22, 2005 under No. 31215), by the Southold Town Building Inspector for a 90 ft. high telecommunications tower facility. The OFD has an existing antenna facility at the Orient Fire Station, also used by the Town Police Department to transmit and receive messages to and from Its various mobile units, marine units and personnel patrolling the areas and adjacent waters. The purpose of the requested wireless communications tower to provide improved emergency communication services for the entire area lying east of the East Marion causeway. Following approvals by the town agencies (but prior to the start of actual construction), the Commissioners of the OFD retraced their efforts to assure the most unobtrusive location for the crucially needed tower, and have, with recommendations for local authorities and members of the Orient community, determined that a location directly south of the existing main firehouse building would better suit the needs of the District and the interests of the community. This location Is fairly close to where an existing radio transmission facility is located, which tower will be removed once the new public safety communications system becomes fully operational. RELATED FACTS: The property is 4.35 acres in size,with 341 linear feet along Tabor Road, a side street, 226 linear feet along the Main Road (State Route 25), 570.70 linear feet along the most southerly property line,and variables along the easterly property line of 169.30 and 287.60 linear feet. The fire house is closest to the Main Road, and the tower Is proposed behind the OFD building. The Orient Fire District has an existing antenna facility at the Orient Fire Station, also used by the Town Police Department to transmit and receive messages to and from its various mobile units, marine units and personnel patrolling the areas and adjacent waters. The purpose of the requested wireless communications tower facility is to provide improved emergency communication services for the entire area lying east of the East Marion causeway. , The new wireless telecommunications tower is in the process of being constructed at the rear of the fire house, behind the metal building, on this 4.35-acre parcel. The tower is Page 3-April 13,2006 " Appl.No.5805-Cingular,Nextel,Verizon 18.-5-13.8 at Orient proposed to be located south of the fire department's metal building located in the rear yard, distant 145+-feet from the northerly property line at its closest point, 140+-feet from the easterly property line, 135+-feet from the southerly property line, and at least 315 feet from Tabor Road to the west. The telecommunications use requested herein on the same telecommunications tower that was approved under ZBA Appeal No. 5408 and Building Permit issued June 22,2005 under Permit No. 31215,Z to the OFD(special district under Section 100-162A), except that It has been moved closer to the buildings on the same parcel, and the co-applicants, as public utilities,wish to co-locate with the consent of the owner/special district(OFD). RELATED INFORMATION: By application dated 6/27103, the OFD stated that an antenna height of at least 90 feet is mandated, to provide the coverage necessary to reach the furthest extent of the mainland Southold,on physical sciences governing public service radio communications. The OFD and Town Policy Public Safety indicate a height at 90 ft. AGL is required, with 'low band' vertical whip antenna and future carrier antennas (see plans prepared by Michael Walker Design/Builder dated 1016104). At the top of the OFD's tower is a 9'6" dipole array to be externally mounted,2.5"in diameter. During the hearings, concerns were expressed and disputed by residents as to whether or not the public utility is eligible to place its antenna facility and use on the site, since the new tower is not existing, although the tower has a valid and current building permit in effect for Its construction. OTHER CONSIDERATIONS: In addition to the matters to be considered in Article XXVI of this Code, the Zoning Board of Appeals has given consideration to the following in issuing a special approval for wireless communication facilities: (1) The height of the proposed tower Is the minimum necessary to render adequate service. (2) The wireless communication facility has been situated to minimize its proximity and visibility to residential structures, residential district boundaries and landmarks designated by town,federal or state agencies. (3) The wireless communication facility is designed and situated to be compatible with the nature of uses on adjacent and nearby property. (4) The wireless communication facility has been designed to use the surrounding topography to minimize its visual impacts. - —4 Page April 13,2006 '^ Appl.No.5805—Cingular,Nextel,Verizon 18.-5-13.8 at Orient (5) The wireless communication facility has been designed to use the surrounding tree, building or foliage coverage to minimize its visual Impacts. (6) The wireless communication facility maximizes design characteristics to reduce or eliminate visual impacts or obtrusiveness. (7) Other adequate conditions have been placed on the wireless communication facility which will minimize any adverse impacts of the facility on adjoining properties. REASONS FOR BOARD ACTION: On the basis of testimony presented, materials submitted and personal inspections,the Board makes the following findings: The new wireless communications tower will be co-Located on a new telecommunications tower, to be constructed in place of the existing OFD telecommunications tower facility, and will meet the height and restrictions placed by the ZBA under Decision No.5408. 1. The proposed Communications Facilities consist of the installation of three(3) sets of panel antennas, each set representing one wireless carrier, internally mounted within a recently approved 90' high monopole. The monopole will be situated immediately behind the south end of the OFD.firehouse, and associated equipment cabinetry for each carrier mounted alongside the monopole within a fenced and screen compound. The co- applicants' proposal represents the least obtrusive means for three (3) FCC licensed telecommunications carriers to provide service In the vicinity of emergency, fire, police, ambulance companies and departments need wireless mutual aid communication systems. The mutual aid and Individual (private) ambulance, .radio and other aid companies are Involved with the mutual aid system. There are existing dispatch problems, problems in scene management, fire safety issues, and fire ground operation Issues. The fire departments and other companies join together to assist as needed,with fundamental resources (low-band paging and radios). These systems clearly need to be Improved and expanded and to provide for more effective long-range communications and senior managing during multiple fire ground and other emergencies. Because safety of citizens and fire personnel is of primary concern, an Improved wireless communications facility is necessary and desirable. 2. Other experts, including that of members of the Orient community, gave unrebutted testimony that effective coverage of the subject area can be provided by a communications tower of 90 feet or less. 3. While safety is the primary concern, other values, such as aesthetic considerations, character of the neighborhood, and preservation of the scenic nature of the State- designed Scenic Byways Corridor must be heeded to the extent that they do not compromise the tower's effectiveness in the locale it Is designed to serve. In addressing visual concerns, the applicant has offered: a) a neutral color and flagpole design, and b) to locate the structure behind the existing OFD buildings as far south from the Main Road as feasibly possible. These measures do not satisfy the concerns about visibility, since Page 5-April 13,2006 Appl.No.5805-Cingular,Nextel,Verizon 18.-5-13.8 at Orient the tower will be visible particularly at the top half portion of the tower where the antennas are visible over the existing buildings and tree lines and not screened from view. A tower structure at 120 feet in.height compromises the scenic and historic surroundings along the State designated Scenic Highway Corridor and Is not consistent with the surrounding rural character of this area, with clear visibility from various segments of the lands surrounding the tower site. The installation of these antennas and public utility telecommunications facility, on a telecommunications tower approved under appeal No. 5408 and Building Permit#31215-Z issued June 22,2005 will be a reasonable alternative to placing a new tower facility on another site to serve within the gap of service for this community,and will meet the strict requirement of the Zoning Code Section 100-162-A. 4. It is the Zoning Board's determination that the co-location of the three antennas onto a new 90 ft. wireless communlcationsltelecommunications tower, to be built at this site of the OFD, is allowed In the R-80 Residential Low-Density Zone District by Special Exception. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Goehringer,seconded by Member Simon,and duly carried,to GRANT zoning approval under Section 100-162A, for public utility antennas and telecommunications use, as applied and shown on the site and pole elevation maps prepared by Michael Walker signed 3/6/2006 (with ZBA date stamp of March 8, 2006),-SUBJECT TO THE FOLLOWING CONDITION: Applicant shall post a bond, in the favor of the Town for the purpose of guaranteeing to the Town that In the event the use of the proposed Tower is discontinued and not used for telecommunication purposes,the applicant herein will faithfully cause the tower to be decommissioned, deconstructed, demolished or otherwise removed from the site,with the site restored to its original condition. Based upon the submission of the applicant and reviews by the Town Engineering Inspector, the recommended amount of such bond shall be not less than $10,000, subject to the approval and acceptance by the Town Board and In a form accepta a Town Attorney. Vote of the Board: Ayes: Members Oliva(Chairwo n),Goehr ger, zio S on Weisman. This resolution was duly adopted (5-0 . Go d P.Goehringer bTili106 proved for Filing RE,NIELSEN, HUBER Sc COUGHLIN, LLP ATTORNEYS AT LAW 36 NORTH NEW YOHK AVENUE HUNTINGTON, NEw YOBK 11743 TELEPHONE: (631) 425-4100 FACSIMILE: (631) 425-4104 OF COUNSEL WILLIAM J. NIELSEN January 24, 2013 By Hand Mr.Michael Verity Building Department Town of Southold Annex Building 54375 Route 25 Southold,NY 11971 RE: New Cingular Wireless PCS,LLC("AT&T") Proposal to modify existing telecommunications facility at Premises: Orient Fire District 23300 Main Road, Orient,New York SCTM#: 1000— 18—5— 13.8 Dear Mr.Verity: We are the attorneys for AT&T in connection with its proposal to upgrade its existing facility at the subject premises. The modification proposed is part of AT&T's "LTE" (Long Term Evolution) project which will allow AT&T to provide better,faster and more reliable service in the Town. The Middle Class Tax Relief and Job Creation Act of 2012, codified at 47 United States Code §1455 (a copy of which is enclosed) provides that "a State or local government may not deny, and shall approve, any eligible facilities request for a modification of an existing wireless tower or base station that does not substantially change the physical dimensions of such tower or base station." We respectfully submit that this proposal is an "eligible facilities request" pursuant to 47 U.S.C. §1455(a)(2) as it proposes only to replace and collocate certain transmission equipment on the existing pole and modify equipment inside its existing equipment area. As such, the proposed modification will not "substantially change the physical dimensions"of the existing tower or base station. Moreover, the Telecommunications Act of 1996, codified at 47 United States Code § 332, as interpreted by the Federal Communications Commission ("FCC") in its Declaratory Ruling 09-99 and Order On Reconsideration 10-144,requires that applications such as AT&T's be processed within 90 days. We enclose the following in support of the proposed eligible facilities request: 1. Town of Southold Building Permit Application form detailing the eligible facilities request; 2. Owner's Authorization; 3. Building Permit Application fee: Check of Bechtel Corporation (Check No. 1161) in the amount of$500.00; 4. Two (2) counterparts of RF Exposure Analysis prepared by Bernard Morgan of Bechtel Communications, Inc., and dated January 14, 2013, demonstrating the project's compliance with • - New Cingular Wireless PCS,LLC(AT&T) Proposal to modify existing facility at Orient Fire District January 24, 2013 Page 2 of 2 the FCC's Maximum Permissible Exposure regulations; 5. Two (2) counterparts of Structural Analysis Report, prepared by Global Tower Services, LLC, dated January 9, 2013, documenting the facility's structural compliance with local, state and federal codes; 6. Copies of AT&T's FCC Licenses; 7. Copy of Deed; 8. Copies of the following Lease Documents: a. Assignment and Assumption of Ground Lease by and among Affordable Housing Associates Inc. d/b/a Beacon Wireless Management and GTP Towers I, LLC, dated February 1, 2008 along with Assignment and Assumption of Tenant Leases by and among Affordable Housing Associates Inc. d/b/a Beacon Wireless Management and GTP Towers I, LLC, dated February 1,2008; b. First Amendment to Structure Lease Agreement between Affordable Housing Associates, Inc. d/b/a Beacon Wireless Management and New Cingular Wireless PCS, LLC, as successor in interest to Cellular Telephone Company, dated December 8,2005; c. N.Y. Structure Lease Agreement between Affordable Housing Associates, Inc. d/b/a Beacon Wireless Management and Cellular Telephone Company d/b/a AT&T Wireless, dated January 20, 2004, including copy of Communications Site Lease Agreement between Affordable Housing Associates, Inc. d/b/a Beacon Wireless Management and The Orient Fire District, dated October 15,2002. 9. Copy of AT&T's Certificate of Occupancy No. Z-32476, dated July 16, 2007 and related Building Permit No. 32073Z, dated June 2,2006; 10. Copy of AT&T's Planning Board Site Plan Approval,dated June 13,2006; 11. Copy of AT&T's Zoning Board of Appeals Approval,dated May 18,2006; 12. Copy of property survey prepared by PJM Land Surveying,PLLC, dated December 27,2006; and 13. Four (4) sets of Construction Drawings with Site Plans and Elevations, prepared by Bechtel Associates Professional Corporation,revision 1, dated January 10,2013. We respectfully request that the instant proposal be processed in accordance with the above and that the appropriate Permit be issued at this time. We respectfully request that our office be contacted when the Permit is ready to be picked up. We can be reached at(631)425-4100. Very truly yours, RE,NIELSEN, HUBER&COUGHLIN,LLP By: ~~' o 'n JC:mk Enclosures cc by email w/o encls.: Ms. Heather Lanza, Planning Director Cy *pF SO�lyOlo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 �l� �Q CoUlm,� BUILDING DEPARTMENT TOWN OF SOUTHOLD October 28, 2013 Re, Nielsen, Huber & Coughlin, LLP 36 N. New York Ave Huntington, NY 11743 Re: Orient Fire District, 23300 Route 25, Orient,NY TO WHOM IT MAY CONCERN: The Following-1 ems(if Checked)Are Needed To_Complete Your Certificate of Occupancy: **Note: Certification by an Engineer required Application for Certificate of Occ ncy. (Enclosed) Electrical Underwriters Certificate. (contact your electrician) A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) ,Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938 ) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept BUILDING PERMIT: 37947 — Modify Existing Wireless Facility k RE,NIELSEN, HUBER & COUGHLIN,LLP ATTORNEYS AT LAW 36 NORTH NEW YOEK AVENUE HUNTINGTON, NEW YORK 11743 TELEPHONE: (631) 425-4100 - FACSIMILE: (631) 425-4104 OF COUNSEL WILLIAM J.NIELSEN April 17, 2013 By Hand Mr. Michael Verity Building Department Town of Southold Annex Building 54375 Route 25 Southold,NY 11971 RE: New Cingular Wireless PCS, LLC ("AT&T") Building Permit No. 37941 -Proposal to modify existing telecommunications facility at Premises: Orient Fire District 23300 Main Road, Orient,New York SCTM#: 1000— 18—5 — 13.8 Dear Mr. Verity: On behalf of AT&T, and pursuant to your office's request, we enclose, herewith, the following documents: 1. Application for Certificate of Occupancy; and 2. Bechtel Corporation Check number 1272 in the amount of $50.00, which amount represents the required Certificate of Occupancy fee. We respectfully request that the Building Permit be released to our office at this time. Thanking you for your courtesies,we remain Very truly yours, RE,NIELSEN, HUBER& COUGHLIN, LLP By: hn J. C u lin JJC:mk Enclosures RE,NIELSEN, HUBER & COUGHLIN, LLP ATTORNEYS AT LAW 36 NORTH NEW YORH AVENUE HUNTINGTON, NEW YORK 11743 TELEPHONE: (631) 425-4100 FACSIMILE: (631) 425-4104 OF COUNSEL WILEIAMM J.NIELSEN February 11, 2014 I By Hand � FEB 1 1 2014 .�1 Mr. Michael Verity '—`���oc, ep� . Building Department 10,r^�,fY.,�o WOLD Town of Southold Annex Building 54375 Route 25 Southold,NY 11971 RE: New Cingular Wireless PCS, LLC ("AT&T") Building Permit No.: 37941 Premises: Orient Fire District 23300 Main Road, Orient,New York SCTM#: 1000— 18—5 — 13.8 Dear Mr. Verity: Our office represents AT&T in connection with the captioned matter. As previously discussed with your office, our firm is working with AT&T to close out the subject building permit issued on April 16, 2013 (copy attached). In response to your office's CO checklist, dated October 28, 2013 (copy attached), enclosed please find two (2) original counterparts of Engineer's Certification Letter of Richard M. Coad, P.E., of Bechtel Associates Professional Corporation, dated February 6, 2014. Should you have any questions with regard to the foregoing,please contact the undersigned. Very truly yours, RE,NIELSEN, HUBER& COUGHLIN, LLP By: J. C g in JJC:mk Encls. Telecommunications Site Review 40 New York Upgrade Version Consultants, Inc. 7050 West Palmetto Park Road,#15-652 Boca Raton,FL 33433 Tel:877-438-5871 Fax:877.220-4593 March 15, 2013 Heather M.Lanza,AICP D E C E Planning Director Town Hall Annex Building EMAR:18 Z013 4 54375 Route 25 Southold Town Southold,New York 11971 Planning Board RE: New Cingular Wireless/AT&T Mobility Site: NYCENY0735 23300 Main Road,Orient Point Dear Ms. Lanza, At your request on behalf of the Town of Southold,New York, CityScape Consultants, in its capacity as telecommunications consultant for the Town, has considered the merits of an application provided by New Cingular Wireless PCS, LLC. a/k/a AT&T Mobility ("AT&T") to modify their facilities on an existing ninety (90) foot concealed support structure. The Applicant proposes to replace three (3) existing panel antennas with three new (3) upgraded panel antennas and maintain six (6) tower mounted amplifiers (TMA) all at the seventy-five (75) foot level. There will be no changes in the feed lines. The concealed facility is a flagpole which, in addition to AT&T, includes communications facilities for Nextel Wireless, Verizon Wireless and the Orient Fire Department. There are numerous inconsistencies between the structural analysis,the RF exposure analysis and the construction drawings. The construction drawings and RF exposure analysis include antennas for Nextel Wireless, but were not included in the structural analysis. The structural analysis lists an antenna and feed line for the Orient Fire Department at ninety-two (92) feet, but is not listed on the construction drawings or in the exposure analysis. The structural analysis states the Nextel location at eighty-five (85) feet as an empty canister with no feed lines. The construction drawings on one page (pages not numbered) states to swap one antenna and on another page it shows the swap of three (3) antennas; none of these inconsistencies are relevant to the Town's approval process so they were ignored, see figure 1. The support facility is owned by Global Tower, LLC. and is located at 23300 Main Road in Orient Point,New York, see figure 2. The purpose for these modifications are intended to provide AT&T subscribers the newer technologies specifically for the upgraded services, known as fourth generation (4G), or high speed wireless broadband service. Smart phones have increased the demand for wireless services by roughly 10 times. All carriers have been in the process of upgrades attempting to maintain their current subscriber base while simultaneously trying to provide improved and advancing services all of which are requiring substantial infrastructure growth. AT&T along with Verizon has been most active in the eastern half of the United States; to a lesser degree T-Mobile would be included. Currently short term system modifications are underway to overcome, to the best extent as possible, current over-capacity problems and, in addition AT&T desires to create high speed wireless broadband services. Future facilities will be more concentrated toward the wireless internet electronics as President Obama's Administration rushes to provide more spectrum to meet consumer demands. AT&T is attempting to bridge the consumer demand for improvements. Advancements in technology are occurring faster than ever before. To make improvements the carrier will modify existing facilities, see figure 3. Carrier:AT&T [ROE= Site/Facility:NYCENY0735 Southold,New York March 15,2013 Consultants, Inc. Page 2 Telecommunications Site Review New York Upgrade Version The Applicant's proposed upgrades will all occur within the concealment of the flagpole resulting in no visible changes. Because the support structure is a concealment and the changes in the Applicant's loading and the omission of antennas and feed lines for Nextel is not problematic to the application. To confirm this CityScape talked with Michael. De Boer, PE, who conducted the analysis and was told the dead weight is inconsequential and CityScape concurs. Without question the overturn moment of a waving flag has more loading concerns that the weight of any internal antennas and feed lines. The final tower rating will be 99% out of an allowable maximum of 105%, see figure 4. This application is considered an upgrade by the Telecommunications Act of 1996. The Applicant supplied an exposure report which shows compliance with applicable FCC rules regarding human exposure to radio frequency energy, see figure 5. The proximity of all the existing antennas and the proposed new antenna upgrades will not create a potential health risk to humans, including the omitted Orient Fire Department antenna top mounted at eighty-two (82) feet according to the FCC OET Bulletin 65; Supplemental C; categorical exclusion. CityScape anticipates this plan, if built as designed,would be in compliance of all federal and local codes. Within the ground compound the Applicant proposes to stack a new electronic equipment cabinet atop an existing cabinet and add six (6) remote radio heads (RRH), six (6) triplexers (combining systems to add advanced wireless services) and a new global positioning system (GPS) within the ground compound, see figure 6. The three(3) submitted documents for this application include the construction drawings,the structural analysis and the RF exposure calculations but were inconsistent. The various documents listed differing participating carriers or carriers in different mounting positions or completely omitted. In each situation the errors were technically insignificant because each error was over estimated or mounted behind a concealment. The Applicant did provide documentation they would construct their facilities in strict accordance with the construction drawings dated January 10,2013. It is the opinion of the undersigned the improvements are justified and will provide the Applicant's subscribers high speed wireless broadband service in and around Southold. CityScape Consultant's, as the wireless expert to the Town, has determined that the application of New Cingular Wireless/AT&T Mobility has sufficient documentation and that with the conditions listed below CityScape Consultants as the wireless telecommunications consultant for the Town of Southold recommends approval: Respectfully submitted, Richard L.Edwards FCC Licensed PCIA Certified CityScape Consultants,Inc. Carrier:AT&T Site/Facility:NYCENY0735 Southold,New York March 15,2013 Consultants, Inc. Page 3 Telecommunications Site Review New York Upgrade Version Does not show OFD Antema at 82 feet ~� TOP OF EXI5TIN6 FLAGPOLE ' 'EXISTINGI NEXTEL ANTENNAS V A.G.L-Sat lnduded is structural anahsis TOP-OF AT&T ANTENNAS P.,FOR,ALL,SECTQRS) " t7V-3, A.G.L Artuai soap of three(3)antem% - SWAP (1);AT&T ANTENNA FOR PROPOSED LTE AT ANDREW ANTENNA (SEE DETAIL,J-SjWk2jAD3) I &ADD (4,01PLEXERS (SEE DETAIL. IlA05). TYP. ALL;SECTORS' 4 OF EXISTING VERIZON;A141ENN,A5 rk_ #65'-0" A.G.L. —� I I I ' I I I , -'-EXTSTING WHIP ANTENNAS I I J FLAGPOLE ELEVATION ¢ o a 1z IT I EXISTING W-O" FLAGPOLE I I l: PROPOSED GPS UNIT ON EXISTING.ICE I ROUTE`OF EXISTING. BRIDGE POST & PROPOSED 'Ifs`COAX I GABLES; CABLE.ROWED'TO DBU (PROGIDE 'i0' MINIMUM,SEPAR&ION FROM'ANY. EXISROP ANTENNA)(SEE DETAIL 1121A/A05)' I I EXISTING GPS UNIT TO REMAIN (TYP.) E?t15}1NG'6'-0 CHAIN LINK FENCE EXISTING AT&T ANTENNAS GRADE LEVEL z 0'—De AGL Figure 1. Tower Elevation and Inconsistencies Carrier:AT&T Site/Facility:NYCENY0735 40 Southold,New York March 15,2013 Consultants, Inc. Page 4 Telecommunications Site Review New York Upgrade Version • DeLorme StreetAtlas USA®2009 r y,; �• - yt� lslarxl l� ,`. 61EDBIP—�S RD -- 41 j AT&T r r �t ,q a 'l �e rI{ �r 1 F' Z� r ar Data use subject to license. ft b Del-arme.Del-omme StreetAOas USA®2009. 0 180 360 540 720 900 www-delarme.com PAN(13.9°W) Data Zoom I" Figure 2. Site Location Carrier:AT&T Lj W Site/Facility:NYCENY0735 to O IR Southold,New York Consultants, Inc. March 15,2013 Page 5 Telecommunications Site Review New York Upgrade Version ,l XITI !G F1. OPbL -- rN z } t C?-ISTIN0 l I+p1FA' TrC� ? A ;AIN reps I: SECT�I� N J` fib: P � ►T&T A1�TE�t1lAv F+IR PRQ� SEC LTE 3 T c J Nt F E i ANTENI o� EE QE;fA1L 1,%,O&2 DIPL A( 3 T c S{�ItA( 1 ATT ANTENNA FaR p'R3R5EQ LTIw i"&7 Q ERF ± SEE ETA1L 1 145 (sE�CTt . Sti41AP 'i �►?&[ NTF CIA F k ; PROROSEa L'IE kT6�T Figure 3. Final Antenna Configuration Carrier:AT&T =MM Site/Facility:NYCENY0735 Southold,New York March 15,2013 Consultants, Inc. Page 6 Telecommunications Site Review New York Upgrade Version Global'rover Services,LLC January 10,2613 Orient Point NY-5015 ANALYSIS RESULTS toraiivateit �'�ivasalutiu>� The.existing fnun6tion hn also beets evoi ,ted. The existing.fomdation was found to, be acearptalble.Existing foundation and geowcbn cal infor nastaon eras provided by Fted .A,Nudd Corporation. Monopole l.Aft.;99% '.qU MA,44YAW_;C0N4CLU1ffl . The existing 90 f,St,ealth Monopole located in Suffolk County(233000 Mum Roar1, Orient Paintj NY is stmetundly acceptable,based upon the EW,222-U 1065 Standard and dw New York Statc Building Code with the prorxftd equip irtstallead. If any,otter changes are proposed,another structural analysis should be perl'omed°to vare 4lte ta:iwer,is iea ampliaiaee,t conf6 mane with the apoh.cable cades and standards.. Should any ftihcr gttalions arisw,plIeasc contact the Global Tower over Services,LLC EnSineering Department at 9Al 400-2206 Global Tower ServicM LIX ttevieuvd By-,OF � � Y Phillip Npjman,E 1, Michael T.De Bfto r}P.EW. UTS Engineering Senrior Director of Engineering Figure 4. Structural Approval Carrier:AT&T WENEMINES Site/Facility:NYCENY0735 o Southold,New York March 15,2013 Consultants, Inc. Page 7 Telecommunications Site Review New York Upgrade Version lam`Ex rcasaree A n. ilygi tor•f't�.pa-ed New Cingulalr Wireless.I'CS LLC(,AT&T)Antenn`FacilityP Site ID: N CEO Y07, 3 4 IViA INROAD OW T,;NV1195" F , �. �8t14�al+�f�,2(P13 SO i-O-TAF iE11oox Be�i�te6'Commuoica#i±���,Tub: Figure 5. Statement of Compliance with Exposure Carrier:AT&T 1--m MEMEWIMME Site/Facility:NYCENY0735 20 On Southold,New York Consultants, Inc. March 15,2013 Page 8 Telecommunications Site Review New York Upgrade Version -- INSTALL(6) PROPOSED RRH'S & (e)TTtIPLEXERS ON PROPOSED H-FRAME•(SEE DETAIL 1.110D/A04) INSTALL NEW ICE BRIDGE WITH ICE BRIDGE POST(SEE DETAIL 1154/06)- RRI)POSED'CPS UNIT ON fXISRNG ICE BRIDGE EXISTING GP5 UNIT Td REMAIN (1YP.) POST do PROPOSED 1/r,COAX CABLE ROUTED TO BBU (PROVIDE 10',MINIMUM. + INSTALL DC6 EXCEPTION BOX &FlBER SEPARATION FROM ANY EXISTING ANTENNA) + + + MANAGEMENT BOX ON EXISTING.COAX SEE DETAIL 1121 A05: T�+ SUPPORT RACK O (SEE D,EAIL 1&1137/A04) Q + +++ + + + + + + + t * + + + + + +' + + + + + + + + 1- + + F � + + + + + + + + I t + t + + + . + + + + + t + t + + + + + + + '. t + + . . + t + O .� .. _ .i. + _ .-•t_._3• -� .�_ + l. _-mod• .._•#�.'i• .. -k + .+- -a-. '_ -+ + + + + + + + + + + . + 4- + + + + + + � + + + t + a- k + + 't + + + + + + + + + + + I. + +- +' + + ,I. + + + + .4 + + { � } t 1 + + + -F } + 4�+ EXISTING ARGUS EXISTING EXISTING EXISTING EXISTING EXISTING 7E21, NOKIA NOKIA PURCELL CCI LUCENT +� POWER 950 1900• DB MCPA WIT UMTS+ CABINET CABINET CABINET CABINET + ! I % EXISTING + L I / \ ' o AC PANEL + ti. PROPOSED PURCELL FMOWS + GABINE$.STACKED ON TOP•O �' a EXISTING P.URCELL CABINET Lo (SEE DETAIL I I11/AO5) EXISTING AT&T CONCRETE SLAB \-1=AiL-NEW ICE.BRIDGE WITH.ICE. BRIDGE POST(SEE DETAIL 1154/A06) 2$w2.' ISTING'TEL:CO-BOX iz o i. z �3;Fr Figure 6. Ground Compound Changes TOWN OF SOUTHOLD COUNTY OF SUFFOLK: STATE OF NEW YORK --------------------------------------------------------------------------------------X In the Matter of the Application of New Cingular Wireless PCS,LLC AUTHORIZATION OF OWNER At the premises("Premises"): Orient Fire District 23300 Main Road, Orient,New York District 1000 Section 18.00, Block 05.00, Lot 013.008 --------------------------------------------------------------------------------------X STATE OF �tfl<VV,-- ) rn�-t� ) SS.: COUNTY OF 3J�`0— ) Arj�6v- l,y-oeA (? , being duly sworn, deposes and says: Ck0,,.rWt,, Q�acAt ee I am the � u,_, ,�.,,,,gf the Orient Fire District,owner in fee of the premises known as Section 18,Block 5,Lot 13.8(the"Premises"hereafter),and do hereby authorize New Cingular Wireless PCS, LLC('AT&T' hereafter),and its representatives to bring such applications for municipal approvals as may be necessary for the upgrade/modification of its public utility wireless telecommunications facility. As such,I will fully cooperate with AT&T and its agents in obtaining any required Approvals. By: Sworn to me this d of ��� ,2012 NO A�K' IJ ROBERT I.SC NOTARY PU ,State of Ky No.4 9,Suffolk Count Expires map R-20 United States Code United States Code ] TITLE 47—TELEGRAPHS,TELEPHONES.AND RADIOTELEGRAPHS CHAPTER 13—PUBLIC SAFETY COMMUNICATIONS AND ELECTROMAGNETIC SPECTRUM AUCTIONS SUBCHAPTER IV—SPECTRUM AUCTION AUTHORITY ..................................................................................:.....................................................__.............._......................................,...............................................,............................................................................................................................................................ ...........:......... 47 U.S.C. § 1455. Wireless facilities deployment (a) Facility modifications (1) in general — Notwithstanding section 704 of the Telecommunications Act of 1996 (Public Law 104-104) or any other provision of law, a State or local government may not deny, and shall approve, any eligible facilities request for a modification of an existing wireless tower or base station that does not substantially change the physical dimensions of such tower or base station. (2) Eligible facilities request — For purposes of this subsection, the term "eligible facilities request" means any request for modification of an existing wireless tower or base station that involves — (A) collocation of new transmission equipment; (B) removal of transmission equipment; or . (C) replacement of transmission equipment. (3) Applicability of environmental laws — Nothing in paragraph (1) shall be construed to relieve the Commission from the requirements of the National Historic Preservation Act [16!L!LC.470 et seq.] or the National Environmental Policy Act of 1969 (42 U.S.C.4321 et seq.] . (b) Federal easements and rights-of-way (1) Grant — If an executive agency, a State, a political subdivision or agency of a State, or a person, firm, or organization applies for the grant of an easement or right-of-way to, in, over, or on a building or other property.owned by the Federal Government for the right to install, construct, and maintain wireless service antenna structures and equipment and backhaul transmission equipment, the executive agency having control of the building or other property may grant to the applicant, on behalf of the Federal Government, an easement or right-of-way to perform such installation;- construction, and maintenance. (2) Application — The Administrator of General Services shall develop a common form for applications for easements and rights-of- way under paragraph (1) for all executive agencies that shall be used by applicants with respect to the buildings or other property of each such agency. (3) Fee (A) In general — Notwithstanding any other provision of law, the Administrator of General Services shall establish a fee for the grant of an easement or right-of-way pursuant to paragraph (1) that is based on direct cost recovery. (B) Exceptions — The Administrator of General Services may establish exceptions to the fee amount required under subparagraph (A)— (i) in consideration of the public benefit provided by a grant of an easement or right-of-way; and (ii) in the interest of expanding wireless and broadband coverage. (4) Use of fees collected — Any fee amounts collected by an executive agency pursuant to paragraph (3) may be made available, as provided in appropriations Acts, to such agency to cover the costs of granting the easement or right-of-way. (c) Master contracts for wireless facility sitings (1) In general — Notwithstanding section 704 of the Telecommunications Act of 1996 or any other provision of law, and not later than 60 days after February 22, 2012, the Administrator of General Services shall — (A) develop 1 or more master contracts that shall govern the placement of wireless service antenna structures on buildings and other property owned by the Federal Government; and (B) in developing the master contract or contracts, standardize the treatment of the placement of wireless service antenna structures on building rooftops or facades, the placement of wireless service antenna equipment on rooftops or inside buildings, the technology used in connection with wireless service antenna structures or equipment placed on Federal buildings and other property, and any other key issues the Administrator of General Services considers appropriate. (2) Applicability — The master contract or contracts developed by the Administrator of General Services under paragraph (1) shall apply to all publicly accessible buildings and other property owned by the Federal Government, unless the Administrator of General Services decides that issues with respect to the siting'of a wireless service antenna structure on a specific building or other property warrant nonstandard treatment of such building or other property. (3) Application — The Administrator of General Services shall develop a common form or set of forms for wireless service antenna structure siting applications under this subsection for all executive agencies that shall be used by applicants with respect to the buildings and other property of each such agency. (d) Executive agency defined — In this section, the term "executive agency" has the meaning given such term in section 102 of title 40. ( PUb.L. 112-9 , title VI, Sec. 6409, Feb. 22, 2012, 126 Stat. 232. ) REFERENCES IN TEXT Section 704 of the Telecommunications Act of 1996, referred to in subsecs. (a) (1) and (c) (1), is section 704 of Pub.L. 104-104, which amended section 332 of this title and enacted a provision set out as a note.under section 332 of this title. The National Historic Preservation Act, referred to in subsec. (a) (3), is Pub.L. 89-665, Oct. 15, 1966, 80 Stat. 915, which is classified generally to subchapter II (Sec. 470 et seq.) of chapter lA of Title 16, Conservation. For complete classification of this Act to the Code, see section 470(a) of this title and Tables. The National Environmental Policy Act of 1969, referred to in subsec. (a) (3), is Pub.L. 91-190, Jan. 1, 1970, 83 Stat. 852, which is classified generally to chapter 55 (Sec. 4321 et seq.) of Title 42, The Public Health and Welfare. For complete classification of this Act to the Code, see Short Title note set out under section 4321 of Title 42 and Tables. Copyright©2012 CCH Incorporated or its affiliates • o � 11252P4255 ' DR.CLAA AA'MON OF CUvr.Nwrs AND ItuS'i'AT TiONS THIS UI•CLARATION tutdu thiH 15th liar of April, 1991 by U tNI' r UItMT PTIM DISTRICT with offlcvH lovat.,d ut. 2.1300 Main Itond► TUL tirl►!ttt.p N+1w Y(.)#-X► 119r,7 (h►)r►-inaftor rirrorrrwA t.(, hH I.hP S1•a'•t', IIECLA1tANT) , aK tltto uwnt►r or promimow dut4cribtid in schudul,u Zi U "A" .+1+nnxiod ht,rt'Lo (hurulrtul•tur rt•furrOd to aH the I►kE';MISKS) 1111rt'K doiiirt+r: to 1'VHtrLeL tho urio and anJoymtrnL of maid 11I41:MT5k:S 5r-'uu and 11nH rur mtut:h purpr►ms, dtltorminud ►.o lrnposo till mnid 11141-mis'wS r n'1' V0vonat1LH and rt,r{Lrictiunti Und doU1t hurclhy cloc:.laro Him; maid ci1'T•t+t)It r►HENTSES Whitt br hald urtd HItn11 be uultvt:ryud nt+bjoct to L•ho folluwlltq c:ovonantM and rumtrLetiunMr W11F;Itl':AS. UI{CI,AItAN'i' 11nH ntttdc, ;tppl l r.nk l ute Lu t 1tc, Hot- » ruck County Utspartlnent or 11c+a1 t:h N►►rv1 viom (ht�rc►lnn!Lur ruforr6d •'•,, , . to am t1u- M-.11ARTHI;N'l') rut, ,t nr►r'mlt Lu I:onrrtrur:L rind/or nppruval C r of plunN for ii r+ingl++ family roaidanc:u► it Nubdivivinrt at• dovel- oih(MIst. or e►tht►t proJnCL rin tho 1 mhr41SXSl and Z• WII11.10.A.11v the. 1►IMMlSES tiro Lo bo j4orvud by an indlvld- u.►l c+rt-HiLr• pt-lVato wulll and W11ERE'ASt Lho LuHt wvl1N Namplod fur tho mil..miSus itt- dlE.►ted It droundwrttar Supply that had contaminot- ion In uxct-rvN or Lh►• minitnuul drink(ncl wat-or Ntitndard un.t/or rluidollnr'H or Lhc• lilat'1• or Now YuI.h .110 4'+111Lalni'd Ilxcomm tit 1111. rollowirlrtr 1-rim •:nd N1Lrat.ol rind is I:omploto 11NI. c,f` ►tn+tlyNi►t rc•;+uSLr+ lrt titLnc;hod rivrutu .IN Schudult► Up and oat:11 cholnical paramutor Which uxuouds Saw of tilts .1000PI-oblu ltwtrl 114 indiCiittxt W.10 ►7n aelturlakl rind WlIERE'A` g 1•1111 County of Su[rulk Uvpnrtmnnt of Hoalth survicum hate agruud ' to lamuo a pormit only if thuru be a record \�I f covenant that the nacomNary WaLor conditi.nttinq uqutptn►ont .bra in- I I,r) et•a.11.!J au ntv to muot. t•.Ftr) quality nt.undarcim for drinking waLorl It is UVCLAIt1{I) and CoVI-.NAN'PI.h by r*.C1,AItAN'1' , Lhnir ltnir'H or nuc- taINNUrt► .utd '.1111.4kIlIn rIAVVur, Lhnt no, rvNicloneo upon the abovu dI'Hvril:;,vd property will kv uixuplud prior to tho inmtallntion of the ncromisary watur condit.iutting uquipment no that thu Muter. whvr+ vondit.Iorlud, InVoLH 0191 said lit ittlmunt quallt.y Htandnl'dN ror lt25 M M drLnkinq watmv of thce 1.11tntu or Now YorK and c-vidunce of Hamu it, furnimllud tv, Out SutFolk Courtty Unpart:mont c,r livalth Stir- v iCON ru►' the►i l' wt'iIA.0n 111111r'nv.i.t ► 3, 111ltt Irl•:t:l.MtANT, IUJ rtur41141110rN mid/or ommigim "hull Hvt forth Chusu c:ovon,uttm, ►groumant.rt and doclllrntlonH In any rind 01 1totimoN tact Uccupdmi-s, Lunants itind/or lummnom of t.hr atx►vv dismcr hod pLupt►t'ly itnd tlhall , by thoI r t vrnul, Hub.)mA Maim, Lo Hus t'ItVolla1tt.H mid I'mAr'1OLItimi cultttlint!d hort.tln. F',tt tur" of the OVULAftWr, itec muccummorN and/or notimignm to yo carviition Uw Wamum Hlutll muL• invaliclni-o thvir aut-1-i►.ir. Nub- itmI.A t on t.0 thu covtinantrl and I'VN t:r I r.1,1 n11N ,1► Alt or tho vovrnrint:" rind r'c,Htr lot lu"m com-.nlmd horv- Lt% t+h.cli W)v c'ttnt~Lrumd to bit in addition to and not Ill dogruga- tlon or. ,limitatLun upon any provisluns ar lentil, Ht:att, And rudttral l.tWtrts nl'dindlice", and/ur rrnulm.lrnH in urrlrrrt nt. thu tAnut of 1t. 1.111, t init, l+ttt'h .1QWH, ordillill com, and/or riiqulatiollN Itl11y Lhormirl.ur bo roviHod, a- mundod ut' pr61t!u1gttlutl. ;. min cic►uutm-m is m►Ido Hub,)cm't to lhv pruvIalon" ur (tll 1 imi rt,qu i rod by law t►r by t hu i r hruv l H itmm t.0 IM 111c OVI)O1.11 L ud hor't-►r► ai%d uivy ary dtullncrcl tt► kx, incorlx►rat.ed 1110ruin and madu a pltl't h('l'Vof p 4H thttug)l fully Not for'tlt, G, 'I'll(, tirorrmc!nt. tmod itr.Htricti.vtl cuvl imam N11all bcs till- rorvis.ibly by t.liv cf.)utty of Nurrc►lk, Kt:,tln or Now Yc►rk, by ill- )u11t'l.(Vi! t't�t lt•f I►1' by any ol.lityr rumudy in Vqu 1 ty 01' %1 .1,1W. The ral ltim of maid ugr►n1:l.uH of t.htr c uunt.y or :iuf full� t.0 unrurem the !tame 41t+111 not bo dom mud to affect. tho validity at thiN romiant nur to ImIximt.► any 11ability r.l..,:.sucwur upon thu County or Suf fo.IX or ar,, of f icor or umployuo tho—.!roof. 7. 'l'htt4e. covunrinta and rout.ri.ctionsi rchall run with tho land tltId rch.ttt hr hlndinq upon Ov DI-XI,A11AN't's ILm succousiorH and uH- Hignws and upon all purmorim or (11k tltbtA gleaming 1,ndur them, and mny bn t.arml nat eci p rovukud or amundad only with thu writ tan con- ticint or tho l.1,31ARTMENTO 0. Thu c1vt:Int'atiunH HOL rc►t'tll In thr• Wlil•;IWAS r,luctHttH ccm- 11252?M7 Laintrd herttlr► t+holl ba elucrmod and cunKtruvd to bu promimom, covonan►m mid raNtrlctiorls tie 1C Cully ropautud and not forth horuln. '►, i f any rtut;tlun, tlubmilvi it►n, porngr.tphp, vinumvp phrt►uo or proviNion of thnNu ccwonnnLO and rantr.lcHonh shall, by a c!cmCt. of cmlnpot-14A }urittdlc!LSorl, lx, adjudged 111ugttl, urrinw- fu l, lttvtt l icl r or hold t n bt, Chu tt.tlnu Moil cult. arclict th., Y'll tdl l y of 111o"(1 t`tivrti.tttt I+ ,ui a whn,lt', or :my of fu r p.t rt m- hruv Nitin horuof othvr than l•hu pt►rt. r►u nd judged to hr itIotlal , unlawful , tnvnIid or unc inmI l luLiunr►1 . 1U. LoCM I,aw IIr'.12-19N11 - 'l'hc+ DI.,VLANAN'I' l'opr1,t11m itu mid w,11•1'-1r11 y Lh,tt hu hatr, nttt orrort'd or Sllvvil nny c1r,1I.111 Ly I o .tl►y orri1'lcr.1 , lvnploytlw, ur dgoltl: of Suffolk County, Now York Stato, or or any political al ptlrty, with Oct purpnmu or intuit of mocur- Inp favorablu Lro4t.mont with rompocL to tho p6rformanco of an .►pruc,mtlr►L, ,tna t.l►nt much person hum read mid itt familinr with Ole provi»lonrl of Local Lnw #32-1900, OItiENT HIRE UI5TRICT 1':11xrrl I:. Lucts, C u. rma lloard of Fire Commismionurn ;'t'A'CI: oF NUM Yk'KK, COUNTY!°M SUr- OI 011 LMH l'il'.h d+ty or April , 1391 bufh►rr mo p raon.►lly upl,.....ud I L11ERT V. LUCI:, Lo n1u lutuwn ttnd knuw►t to mV Lo be Lhu ttarrin individ- ual dumcrtbod .in and who oxocutad tho rtbuvo WmLrumunt and hu duly .1c=kria% Lo my that ho oxticutud Lha •tim. Notetry t'ubll� i...•. , � ,7t Ih,r�.!,In 2t25292% c3Cii OU1,t'' "All i3P,CLAI:Avis uNIN:N'r VINE ntSTl+i(:7 ALI• that tv0 .011 Ial(,l , NICK'(' (W pors't"11 Of 1 Bond, 1Y(ncl, H(t - ,t.tto +lncl I,(siml at Or1(+nt.0 ToWsl of SgAttlioldt County Or "uflnik ,utd. St al is ur D!",+ Y(►t'kl buundtid slid clopwribied at; follmai 1W.111NN7NO at. 1110 Intormoction of Chu NuklWerly lino of Main kn.id with Lho must-orly lino of Tabor Raad and runninq along ,ynid smitltc►rly 11mu or rinln 14und, NorlAw HO dogro(►H .11 minutom an Hr, MICIN IINVO., 226,0 Carl. Lu it munumunt, and .lands. nwo itir formerly of verroiral 'i'WiNVU tilonq .land or Furr(�1 rst !iuuf.li '.I d��clrova 2t1 mi nut(�1( JO N( CrindN rout) '1111-MC1{ North 87 do4rucu 47 minutum 30 s oconds l,avt along 1(nid lmidrs cif 4orvoIrm mul 1atnr monq land of moria and (dents Imid (,f Wl,mlkowuki , r(•nt. I.0 a uiutuumvnl. and lmid or 'I'IIt,NCE altmcl Huld bind of 'Parry, South 21 dmiruuK 20 niinut-va 00 NI!('(lt1c111 I',i1Nt 1 211Li,t) 1 C( ( t) rIIFNm-'. along nthor Wild of Schrv1vur, South 113 dugrnue OJ m1n. utt,a 50 Hocunds WvsL, 570,113 flat. to HW VaHL(i1'ly Kic1u of 'T'.,l,or u(aull IMENCE. a l uitcl w,i id 1 NI. W Tabor lt►atd two c ou s'N(►H t ( l) North 0 do(Irvil D minut.«N 00 nocuilds Womt., :142,05 Cs�(•Ll ( 2) North 11 dugrm-pi Y? IninutoN 00 "ovond,r WoHL, 116, 75 root, Lo Lh(s pulnt cis' plac:u of 11F.01NNINO, I?iAtrict: 1000, Sc,atlun 010,000 Muck 05,OU, Lot, 013 ,008 K 112U92M S MS. ��u� i)E.Ct.AHANTl oltrh:Mr rim.,, .ut.writrcr C)IHtrlCL LOGO) SOULkill 010,00, MUCK 05,00p Lot 01:3,000 112529260 SCHIMULE ► C" ORMARANT i plt F 1;NT r I RF, D 1 S'(VI M' :,uC�ulk Cciuttl'.y 13ap4rl.monL of }ludl.Lli Survic:u" Water, Analysis datod Uc-min er 3► 1990 npputidnd huruta and mada a part beroof, lt��wult.K it► oxcomm or (►a% or mltilmum ►ttdards aro art fullaw► 10.7 10.0 mg/l *Su1 f M-o 10 250. mg/l *,I roll U►tic) 0►3 mg/1 11252461 lmr = Cot11r11Y OtlrlutVioL>A! Or IOU" 111MC111 • ►&IMA AMMTMZi NASS 1011>l20 1 2M DIVARrAW - now hm i l d i ng ADDRX88i MAin and Tabor Roads, Orient 8MNL2 DAM 1211/00 Result llYa.�^,>:.... total coliform <2.2 r2.2/100 ml alpha•MIIC <Ilu.2 $pacific concl, 5b0 - %wehns/on beta-PHC 0,2 - pll . . . . , . . . a . , 4. 1 _ - aatmma-%HC a . . , , . <0.2 nitrate 10.7 D0,0 •9/1 delt4-811C . . . . . 0.2(too ammonia ammonia 0.14 sts. "/1 llndsne (sing hHC) 1. ppw ahlorlde )i. 250, niq/1 haptachior <0,2 sultate , , , . , , 1671 250, Mq/t heptachl' ♦pnNlil• <0.2 iron 0.49 0.1 1�q?L� aldrin . . . . . . . . . 40.2 manganese so . <0105 0.1 „q/%- dialdcin . . . . . . . 40.2 Copper 40.10 1.0 nq/1 411 DDi 0461 . 1 . 4 <0.2 - sudluls 1910 - ln9/14- 4,4 1000 . . . . . . . . <0,2 - sine 014 5.0 0q/l 4,1 DDT . . . . . . . . <0.2 - cadmium . ., , , . <2, 10, ppb endcln , . , , , , , , , tO,Z 0.2 ppb lead 0. 50, ppb ondeln aldehyde 0.2 atdloarb <1 y ppb chlordane a , , , . . <1. eacbotutan , . , <t 15 ppb alaahlor 11 . 11PI 40.2 2. ppb nxaMyl , , , . , , , <1 50 ppb riithoKyahlor , . , <0.2 50, oatbaryl <1 50 ppb endosullan 1411 <0.2 - Merhr+,nyl . , , * . <1 50 ppb Msthiocarb ari 50 ppb baygon . . . . . . . . <1 50 ppb NDAb - detergents <0,1 mg/1 mq/1 a milligrams per liter Icon and mnpanese combined should not exosed 0.5 mg/l. ♦ Moderately rostriated sodium diet should not exceed 270 wall. Severely resticted sodlum diet should not exceed 20 mgll. ltanult ltaauiC vinyl chloridn <O.J (2) bensone 140.5 methylene chloride 0.5 toluene <0,5 t, l dlohlotosl.hane 40.5 chlorobansene <0.5 trans t,2 dichlocoothen• 0.5 ethylbsnsene . . . . . . . . . . . . . . . . <01h ohlorotorm <0,5 1100) o-xylene <0,5 1,2 dtohlocoethemm . . . . . <0.5 m-Nylons 0.5 1, 1, 1 trichloroethane 40 A p-xylsne <0.5 carbon tetrachloride , , , 0,5 total Nylons - 1 brome 2 chlorcethane 0.5 O-chlorctoluene , , , , . . a , . , . .. 0.5 1. 2 diahloroprapene , , , . <0.5 m-ohlorotaluene 0's tttahlotoethena roll p-ohlocotolusne <015 ohlorodibroaomethans <0,5 (100) total chlorotoluene - 1,2 dlbromosthane . . . . . . <0,5 (0,051 L, 1,5 trlmethylhonsone 40.5 2 breAw t chlotopropane 0,5 102,/ trimethylbsl+sene . . . , . . 0,5 hr(Yerolorm <0.5 (1001 m,p•dlohlocr"nsens 40,5 tatraahloroethene 40,5 o-dichlorohensanp <0,5 cis dichlnroethens t . so , 40,5 p-dle!hylbenssne 40.5 boon 111 <0.5 1,2,1,5 tetrarnsthylbsnssne 40,5 dibcoteomethene <0,5 t,7,4 trlohlorobonaene 40,5 1. 1 dlahlaroethene 0.5 1,2, 1 trinhlorobensone . 40.9 bromodLohloromrthans , . . <0.5 11001 ethanylbenrane Istyronel . . . 40,a 2,1 dtahloropcopono -10.5 1 methylethylbensens (oumene) 40.5 cis dldhlncopropene 40.5 n-Qcopylbrnssne 40.5 trans dlohloropropone 40.5 text-bbutyYlbensene <015 1,1,2 triahloroothane . . 40.5 1so-butylbens2ns . . , . , , , . . . . . 40.5 1, 1, 1,2 tetraahlo'ethare <0,5 NapropYltoluens 1p-ayoene) <0.5 -�etraahlataeehane . .. . <0.5 n-bo Y snsene , , . , , . , , .,. , aa <0.5 l,2,3 ttiahlorapropans <O.y hanaohlotobutadiane , , . , . . , . , <0.5 2,2 dichloropropane <0.5 l.1 diohloroppropane . . , 40.5 N0791 < symW means "tNse than- 2 coloroethylvinylether 40.5 indloatlnq Cti detection Maximum Coakminant Lrvsls (MCL' s) tar volarile organln anti hydrne,arhon compounds are 5 pacts per billion Ippb1 each. Lir4to astablished for Individual compounds are, noted to pacenthesssll . MUM i 1.4 09CLA"TI.ON OV (.'WUNANTS AND WST4iIMONSi OR I ENT MH DISTRICT FILgD T� , P:DMARD JOHN BUYD V o KIBQ, '`�;'�• �0 54653 HAXN kuA0, BOX 1460 ;•.�;r � SOUTHOLD, MY 11911 ,•. ,i RECORD" 211199, 'C : vi gyp, ' ' '' `•i aoa �r L �• fYbt���� at to •i y{) i �O1/'YviaG'� ••ti ,s!'t ••�r �y>• !il iRE allPlltt 'r tii ibi address a a �, Orch- o fr `I ati . 'Ndv Toot, ""3 pop d•dkt uos1�6 lY1 a6� M}ciila�irt.i,aad�i�iifti,d�o[cae chid lid idliar'" t ONV Odr lido d th a118 prtAd liar ode On payt of da i�r�iad. ' + a owr bw.ssdadf di of lkif iio.ii` .. „ z V I•:% A .. 'IMIirY�add•inprsaassara Drdadw/It •.;���•,�� Ike• , . ileum of southalol. Count ,uid'Rtate of New York, hnunded•indl' •'t lsl Art-3 lNddarieed,as+.dollf}: t !�,.-- -�i bob' ' NEGINM1ia';�t tre in twir.41 f the south;rrlY, 'A n.4,9114ai 99 . t1oOs with•3heAes Orly 1 i' - 9ldt Ibed ante runalisq.,a1--_ sa ffi>1.00 souteeElY 1i�i+r of �taili;. fix�Eth 00 degrees 31 minutes'a0 seealAls Fast 226.0 fdib o.dr ,iR4silit.-and.bands now or formerly Yf:rreiraf thence aloft-twit �+o'>s •Tarreira ,south 9 degrees 25 minutes,'', ka 3n wr:•onrls 2Fwat A0o.30.E�tvthedh worth 97 dearoas Yl n,nut9f 30 Sr00 jLp',Is 61 suft-j� Kii-M-S�i�d! d[ *wreira anti later along IAnd. . Glor •A a:n0 a3dlaq I+fna'o[:,DiYiirko ki 276.52 toot tl/ t• and}' A �#�ivvNulas*1AV*%vin said land f To 1 • a d t Od ta.� 248.04 tee then a ,. 163 Minl,tee 50 se s sib'd t'i M + � :raAor heart thenci ai0- is it Lima tva>?' , f 1.) North 0 degrees 3e minutes d'0 !�►��''3'.t+.'D� 1 a 'Ndl th s degrees 39 minutes 00 point or pl.:o of 1!CG1NNI"G. s$YffG i1drY9ri�tllb 7+C,• laws- .presisea as can eyed to the V , party.61 W L�� ps9Et ,l�d dated Jely 31, 1969, r 'Alquse ss.1969 if, I.ilf�t is ,.g� 420. .... J r.a r ra1•F i ta,ra Eola .• 1ri► .a !� •�.• W�1y�tq♦���..�j ,fl i ,. �! .aS .",Jja;p. ... -.b tr de i•t!V I• 3 S • G1 e P. r.. #VAxa, TfI1lN/i_�ITAX h' + �j "`S� ` C01i TY rrt i TMTUM sia an r,�a,err acid aiiagdr.lihfwraf:dda pair of O,it*toot to art to ar a,raan,ad ' a .r,a aiwreadaerild arndl�rlildn fin,fame!:Tfj4ET11Ek eid„Ilr nikWWtWhr:rd *rd Y and ra d ymwom- Tft MA1f6 allll[� j n 16aallia sA.6irs rw wMasw•aM arihln aI� r d4 wV of dt mWad vkR4&~t I"1 MF ` •�' i .... Le}.va M G 1.• .ir 1 D Of dte bar pad e«t *A d,a Aan,Id the 6:1r turn h„n,*OW 0 wEr'.aa; It 6w annrlhed'I in ay.air ohm-wr ear•p,r,OW-." • in with Sretra„1!00•b,pan 1•ar.nw!ld,l,l*a*A Mr1 uf. MYYw re caaridelsalai%r ale aalreyanu aM NO hd4 00,ry[hd w 017+w:ledd be*w ate ptrpw of pey,rd,h•c wt of urc apt am :1 a4ae ew bf ft b9man eta brfar-v-9 a,w, yw:.t sf�wul >a s"se wsa irii. • kr tal,rHred as if•end-pa•trd~.m.n•>~r t1w va,e 1A lh,r u,da,e It""Cwt ' Won),d dba ire pea has eyy raaa,wl tl:.4,.1,d.4y..d t..r r..i.A..'� elf. M;�. .,.tr•,�`.y.A., 4 w/.i �'7• nn. •. .. '{O�u r'W7r• N o. ., , 1 %go t,1e Sth V. I _ 1P.9 V 0. :t 4 _ �`-1/Le�lew,.s. ,f,�,. y.+• _ _ ..»ram.""-•- 1_--J16 .r - --" to or Isr.r�i so bri��3AM �� �lm� y ' Al�7ii� � Ant -Iva 3 w W A�wH •NI tt 41 r r .r•„•. .'lr•iidf IV' "s%m .r-M Yr ►�K vi p!a(r, r 'S a;ww,Alt HI• :r .., .��. ..r ,wK..f w.; • ' �f �nfia'/W0 p•►fY'Jt:r�Fw v. .. . .i. • .� Id•A f '} �f{yt•. f.Q aMfi,.v'�" :l' 1 • •�.It•f'ri r7c, '� t �/iT 1a1 rat r f f am WAN- :i1 i �W-�1�y. •.•ui • , 'h�n�a.,ru► ar ,• �•'� .•��,: ,.al �•�f,q,:d� Ift ONOMWO' on dwr�►►yf' �'�1l: 1�Nrtir met 10 t..G t' ib11j�R riire� �. r . rdoll iow . 'r Fi�MA Hirt w��Ide '�� •��1', ie'iAen ,'.�,�:. .4_ ,,,;i iflws fir 11r full,fi� 41111 cif 4n* M1,10 VAk trµr LQ�. »y fir' i" A �4 v.i� ► ar•r � ♦•r; ':•�;y�i• ilk �•� .. s i 1� . Sri y y .w11Rt1 OR TOM ..., •i 'rr;J lf2t�t7! *4rll ,v re• i r ,r A ,.�,y � ya 4. i• e�eel� � 5 �44' �S main lRowd,r, w„ W A 4 16%4r.,a l thalde Now York 11971 ; Ile '� d �#t���� i�'!1 4 v. .• � ti t tw". !.�v�i t6l it-104 9lSL��Qt '• t'Y•1j Jj1J�ZiRPl.yl)1lKE F r... 7{ iJ f*ot liftM!, •.f►n!n w.gtP,Ile 11�iN E?S�AOlM!SO4'/Y_V,�id1+ • t•$•f 'W!lfi f r..w of rr iv`rrl►r..Yw .. .l _ fi s 1 i Prepared by and When Recorded Return to: Global Tower,LLC Attn: Legal Department 1801 Clint Moore Road,Suite 110 Boca Raton,FL 33487 GTP Site ID:NY-5015 GTP Site Name: Orient Point ! ASSIGNMENT AND ASSUMPTIO4 Or GROUND LEASE THIS ASSIGNMENT AND ASSUMPTION OF GROUND LEASE(this"Assignment") is entered into as of February 1, 2008, by and among AFFORDABLE HOUSING ASSOCIATES, INC. d/b/a BEACON WIRELESS MANAGEMENT, a New York Corporation ("Seller")and GTP TOWERS I,LLC,a Delaware Limited Liability Company("Purchaser"). WITNESSETH WHEREAS, the Asset Purchase Agreement dated as of September 27, 2007, (tire "Purchase Agreement"), with capitalized terms used herein without definition having the meanings set forth therein by and between GLOBAL TOWER, LLC, ("Olobai Tower") and Seiler provides for the sale by Seller to Global Tower of the Tower Assets certain of which will be sold by Seller in connection with the Initial Closing, WHEREAS, Global Tower has assigned its interest in the Purchase Agreement to Purchaser and; WHEREAS,on the Closing Date, Seller will assign all of its interest in the real property lease described on EXHIBIT A (the "Lease") to Purchaser in accordance with the Purchase Agreement. (00204580;v1} *. } . c i GPP Site ID:NY-5015 GTP Site Name: Orient Point NOW THEREFORE, in consideration of the premises and the mutual covenants contained herein and in the Purchase Agreement, Purchaser and Seller, intending to be legally bound,agree as follows: 1. As%i,nment of Lease; Seller hereby assigns to Purchaser all of Seller's right,title and interest in, to and under the Lease, being the same premises leased to Seller. Together with(a) such rights of way and easement on, over, under, across and through the adjoining lands of landlord or of record, extending from Premises to the nearest convenient public road and of standard vehicular width as shall be necessary for ingress and egress to and from Premises; and (b) such other tights of way and/or easements, if applicable to run guy wires to such points on landlord's land to properly support towers and install anchors to secure said guy wires. 2. Acceptance and Assumptiori of Lease: Purchaser hereby accepts the assignment of the Lease and expressly assumes and covenants in favor of Seller and the Lessor under the Lease (the "Lessor") to discharge and perform, as and when due, all obligations of Seller accruing, arising out of or relating to events or occurrences from and after the Closing Date under the Lease. 3. Purchase Agreement Controls: Nothing in this Assignment shall be deemed to expand or diminish the scope of the rights of any party to the Purchase Agreement that are contained in the Purchase Agreement. If there is conflict or an apparent conflict between the provisions of this Assignment and the provisions of the purchase Agreement,the provisions of the Purchase Agreement shall control. 4. Counternarts• Facsimile Signatures: This Assignment may be executed in counterparts,each of which shall be deemed to be an original,but which together shall constitute one and the same instrument. Facsimile signatures on this Assignment shall be deemed to be original signatures. 5. Successors and Assins: This Assignment shall be binding upon and inure to the benefit of the parties hereto and their respective successors and assigns. d. Further Assurances: Seller and Purchaser agree that frown time to time each of theta will execute and deliver such further instruments of conveyance and transfer and take such other actions as may be reasonably necessary to carry out the purposes and intents of this Assignment and the transactions contemplated hereby. [Signature Pages Immediately Followingl (00204580;VI) } I IN WITNESS WHEREOF, the parties hereto have executed and delivered this Assignment to be effective as of the date first above written. SELLER AFFORDABLE HOUSING ASSOCIATES,INC. d/b/a BEACON WIRELESS MANAGEMENT A New York Corporation By:y�Gr' Name: r R e� j j r• ,�U i c, Tife:__ �'�P� STATE OF: OI cutz COUNTY OF:// 50 � I, h'4S 6 An Notary Public of 5b ' olk County and State of. AZW do hereby certify that jjac �sonally came before me and acknowledged that he/she is .--.of AFFORDABLE HOUSING ASSOCIATES, INC. d/b/a BEACON WIRELESS MANAGEMENT,a New York Corporation and that as being authorized to do so, executed the foregoing instrument on behalf of said corporation. S� Witness my hand and official stamp or seat this c� day of `_ ��U�' ,2008. Notary Public Signature Print Name: i My Commission Expires: A(k1125�.A1f88T5011 1i0t3l��a61�,$tlteOft�AWYOr� (NOTARY SEAL] tio,E}?�N45�1I flua4e in Suffof<CCAani� Mycma:i*P oom 1@nvWhei30,24 (0020458%1VI) 1 f i (Purchaser Signature Page to Assignment and Assumption of Ground Lease] GTP Site ID:NY-5015 GTP Site Nante:Orient Point IN WITNESS WHEREOF,the parties hereto have executed and delivered this Assignment to be effective as of the date first above written. PURCHAS&R: GTP TOWERS I,LLC A Delaware Limited Liability Company By: (, Name:Marc C.lGanzi Title: Chief E ecutive Officer STATE OF:FLORIDA COUNTY OF:PALM BEACH 1,the undersigned,a Notary Public of &WA County and State of Florida, do hereby certify that Marc C. Ganzi personally came before ine and acknowledged that he is Chief Executive Officer of GTP TOWERS 1,LLC, a Delaware Limited Liability Company,and that as Chief Executive Officer,being authorized to do so,executed the foregoing instrument on behalf of said limited liability company. Witness my.hand and official stamp or seat this .81s�day of January,2008. Notary eublic Signature Print Name:evfi ;k A.Tl iets5 My Coimrnission E pires: 5 [NOTARY SEAL] {00204580;vI } F �s i GTP Site ID:NY-5015 GTP Site Name:Orient Point EXHIBIT A Site Number: NY-5015 Site Name: Orient Port Landlord Name: Orient Tare District Original Tenant Dame: Affordable Dousing Associates,Inc.,A New York Corporation d/b/a Beacon Wireless Mgmt. Current Tenant: Afffordible Housing Associates,Inc.,A New York Corporation d/b/a Beacon WirelessMgint. Lease Exe Date: 1011512002 Recording Info for Lease: N/A Legal Deserintion_ A Leasehold Estate,said leasehold being a portion of the following described parent parcel; BI GINI IMG at the Weave.ion of the southerly line of iV aia Road,v6ith the easterly lice of Tabor Road and numiag,aloes said southerly line of Mainkoad,North 80 degrees 31 tuinutes 30 secoacts East 226.0 feet to a monument and lan&uow or formerly Ferreira;thence along land of Ferreira South 9 degrees 2811riuutes 30 seconds East 169.30 feet;thence North 87 degrees 47 mbiutes 30 seconds Eabt aloug said lands of Ferreira and later along Ia11d of Gloria a11d al along land of Wenlikovvski 324.52 feet to a ntoatuuent and tand of William Terry, Jr.;thence along said laud of Terry 2I degrees 20 minutes 00 seconds East 288.04 feet;thence.along other hind of Schriever South 83 clegrees 0-111t41ures 50 seconds Wear 570.83 feet to the easterly side ofTabor Road:thence 410119 Said Blue Of Tabor Road t1.'kO CO IMS- (1)North 0 degrees 38 mfindes 00 seconds West 142.05 feet: (2)North 4 degrees 39 minutes 00 secoMs West 116.75 feet to The point or place of BEGINNLNG. BEL O AND II�t"MMED to be.Hart of the salve promises as conveyed to the Harty of the first pact by deed elated July 31,1969,recorded August 5.I969 in Liber 46598,Page 120. AND BEING the same propertp conveyed to Orient Fire District from Barbara E MVht Scluiever by Batgaitl and Sale Deed dated November 14.1985,and recorded:November 21.19b5 in Deed Book 9919.Page 570. Tax Parcel No.013.008 (00204580;vr) sf L'a rJ ASSIGNMENT AN ASSUMPTION OF TENANT LEASES THIS ASSIGNMENT AND ASSUMPTION OF TENANT LEASES(this"Assignment") is entered into as of February 1,2008,by and among AFFORDABLE HOUSING ASSOCIATES 1 INC. d/b/a BEACON WIRELESS MANAGEMENT, a New York Corporation ("Seller") and i GTP TOWERS 1,LLC,a Delaware Limited Liability Company("Assignee"), WITNESSETH WHEREAS, the Asset Purchase Agreement dated as of September 27, 2007, (the "Purchase Agreement"), with capitalized teens used herein without definition having the meanings set forth therein by and between Global Tower,LLC("Purchaser")and Seller provides for the purchase by Purchaser from Seller of the Tower Assets;certain of which will be sold by Seller to Purchaser in connection with the Closing. WHEREAS, on the Closing Date, Seller will assign all of its interest in certain of the Tenant Leases to Purchaser and; WHEREAS,Purchaser has assigned its interest in the Purchase Agreement to Assignee. NOW THEREFORE, in consideration of the premises and the mutual covenants tontained herein and in the Purchase Agreement Assignee and Seller, intending to be legally bound agree as follows: i 1. Assignment of Tenant Leases: Seller hereby assigns to Assignee all of Seller's right, title and interest in, to and under the Tenant Leases listed on EXHIBIT A attached hereto (the"Assigned Tenant Leases"). 2. Aceeptance and Assumption of Tenant lases: Assignee hereby accepts the assignment of the Assigned Tenant Leases and expressly assuines and covenants in favor of Seiler and each of the lessees under the Assigned Tenant Leases(the"Lessees")to discharge and perform,as and when due,all obligations of Seller accruing, arising out of,or relating to events or occurrences from and after the Closing Date under Assigned Tenant Leases. 3. Purchase A.,,greement Controls: Nothing in this Assignment shall be deemed to expand or diminish the scope of the rights of any party to the Purchase Agreement that are contained in the Purchase Agreement. If there is conflict or an apparent conflict between the provisions of this Assignment and the provisions of the Purchase Agreement, the provisions of the Purchase Agreement shall control. 4. Counterparts Facsimile Signatures: This Assignment may be executed in counterparts,each of which shall be deemed to be an original,but which together shall constitute one and the same instrument. Facsimile signatures on this Assignment shall be deemed to be original signatures. {00204581;vl; i i i S. Successors and Assigns; This Assignment shall be binding upon and inure to the benefit of the parties hereto and their respective successors and assigns. 6. Further Assures: Seller and Assignee agree that, from time. to time, each of them will execute and deliver such further instruments of conveyance and transfer and take such i other actions a-, may be reasonably necessary to carry out the purposes and intents of this Assignment and the transactions contemplated Hereby. [Remainder of This Page Intentionally 1#1 Blank] I 4 (00240458 J.V I f L Geller Signature Page to Assignment and Assumptlon ol'T'enant Leases] IN WITNESS WHEREOF, the parties hereto have executed and delivered this Assignnment to be effective as of the date first above written. SELLE ArF'ORDAIRL,E HOUSING ASSOCIATES INC. d/b/a BEACON WIRELESS MANAGEMENT A New York Corporation 13y: Name: Vi&r r CA,n1Nafcto Title: r"'r gnoewr— STATE OF: &W Ve&k_ COUNTY OF: Jd&i_iajk- The foregoing instrument was acknowledged before me this 3o day of January,2008,by v ocsxr C A�o of Affordable Housing, Associates Inc. d/b/a Beacon Wireless Management,a New York Corporation on behalf of the corporation who is personally known to me. Notaij Public Signature Print Name. _C..GchC+n My Commission Expires: 73 (NOTARY SEAL) (aozuassF:v l) I [Assignee.Signature Page to Assignment and Assumption of Tenant Leases] ASSI GTIP'TOWERS I,LLC A Delawar 1,Limited Liability Company By: Dame:Mare C.G nzi Title: Chief Exe utive Officer STATE OF: FLORIDA COUNTY OF: PALM BEACH The foregoing instrument was acknowledged before me this 3)`day of January,2008,by Marc C. Ganzi, the Chief Executive Officer of GTP TOWERS I, LLC, a Delaware Limited Liability Company,on behalf of the company,who is personally known to me. �d Notary P blic Sign ture Print Name: My Commission Expires: ai Ocs [NOTARY SEAL] -;.h C�a�a�ir.5ir,;:f-1)U322T6k 6 d'1i:ni {Oi}204S81;v1) t EXHIBIT A Assigned Tenant Leases NY 5015 Orient Point Nextel Communications 1121/2005 7121/2005 NY-50% Orient Point CellularTele*e Compn dlbla AT&T Wireless 1120QO04 1211/2006 NY 5015 Orient Point New York SMSA Limited Partnersh ,dWa Verizon Wireless 3115/2005 14/1I2006 I i {00204581;vl) } i� a• I_: FYCENyvm I.. CeR Site No.NYCENY0735' Market: East/FSA 3 Address: 233.00 Main Road;Orient Point,NY 11957 FIRST AMENDMENT TO NY STRUCTURE LEASE AGREEMENT ` THIS FIRST. AMENDMENT TO NY STRUCTURE LEASE AGREEMENT ("Amendment"), dated as of the latter of the signature dates below, is by and between Affordable Housing Associates,Inc.d/b/a Beacon Wireless Management,a New York Corporation,having a mailing address of P.O. Box'303,.27 Oak Lane, Hampton Bays,NY 11946 (hereinafter referred to as "Landlord") and New Cingular Wireless PCS, LLC, a Delaware limited liability company, as successor in interest to Cellular Telephone Company, having a mailing address of 6100 I: . Atlantic Boulevard,Norcross;Georgia 30071 (hereinafter referred to as"Tenant' WHEREAS, Landlord and Tenant entered into a NY Structure Lease Agreement dated January:20, 2004, whereby Landlord leased to Tenant certain Premises, therein described, that are a portion of the Property located at 23300 main Road, Orient Point, NY 11957 ("Agreement");and WHEREAS, Landlord and Tenant desire .to amend the Agreement to replace LE-3 on Exhibit il and WHEREAS, Landlord and Tenant desire to amend the Agreement to modify the notice section thereof;and WHEREAS, Landlord and Tenant desire to amend the Agreement to. permit Tenant to add, modify and/or replacip equipment in order to be in compliance with any current or future federal; state or local mandated application, including but not limited to emergency 911 j l communication services; and WHEREAS, Landlord and Tenant, in their mutual interest,wish to amend the Agreement as set forth below accordingly. NOW THEREFORE, in consideration of the foregoing and other goad and valuable consideration, the receipt:and sufficiency of which are hereby acknowledged, Landlord and Tenant agree as follows; 1. Landlord agrees Ito allow Tenant to install its antennas at a height of 70'-80' on the Communications Tower. to accommodate Tenant's needs. Upon the execution of this Amendment, Landlord. leases to Tenant. the Premises as more completely described on attached Exhibit 1-A. Landlord's execution of this Amendment will signify Landlord's approval of Exhibit 1-A. Exhibit 1-A hereby replaces Exhibit I,1,E,3 to the Agreement. 2. Notices. Section 17 of the Agreement is hereby deleted in its entirety and replaced with the'following: NOTICES. All notices, requests, demands and communications hereunder 2005 Form Amendment will be given by first class certified or registere mail,return receipt requested,or by a nationally d recognized overnight.courier, postage prepaid, to be effective when properly sent and received, refused:or returned undelivered. Notices will be addressed to the parties as follows. As to Tenant,: c/o Cingular Wireless LLC, Attn: Network Real Estate Administration Re: Cell Site# NYCENY0735, Cell Site Name: Orient Point 6100 Atlantic Boulevard, Norcross, GA 30071, with a copy to Cingular Wireless LLC,Attn: Legal Department 15 E Midland Avenue,Paramus, NJ 07652 Re: Cell Site.#NYCENY0735, Cell Site Name Orient Point; and as to Landlord, P.O. Box 303, 27 Oak.lane, Hampton Bays, NY 11946. Either party hereto may change the place for the giving of notice to it by thirty(30)days prior written notice to the other as provided herein. 3. Emergency 911 Service. In the future, without the payment of additional rent and at a location mutually acceptable to Landlord and Tenant, Landlord agrees that Tenant may add, modify and/or replace.equipment in order to be in compliance with any current or future federal, state or;local mandated application, including but not limited to emergency 911 communication services. 4; Memorandum.of Lease. Either party will, at any time upon fifteen (15) days prior written notice from the other, execute, acknowledge and deliver to the other a recordable Memorandum of Lease substantially in the form of the Attachment 1. Either party may record this memorandum at any time,in its absolute discretion. 5. Other Terms and Conditions Remain. In the event of any inconsistencies between the Agreement and this Amendment,the terms of this Amendment shall control. Except as expressly f set forth in this Amendment, the Agreement otherwise is unmodified and remains in full force and effect. Each reference in the Agreement to itself shall be deemed also to refer to this Amendment. i 4 i f 2 2005 Form Amendment i ' 6. Capitaiized Toms. All capitalized terms used but not defined herein shall have the same meanings as defined in the Agreement. IN WITNESS WHEREOF, the parties have caused their properly authorized representatives to execute.and seal this Amendment on the dates set forth below. LANDLORD: Affordable Housing Associates,Inc.d/b/a Beacon Wireless Management,a New York Corporation Name: Vincent Cannuscio Title: Presiden� Date: i l��� i TENANT: NPe: less PCS,LLC a , iability company Nnn Tlementation(NY/NJ) D i. S i' 2005 Form Amendment TENANT ACKNOWLEDGEMENT STATE OF MIT � )ss: COUNTY OF BejrQ e O � ` On the day of OJ 200,5 before me personally appeared ---- ~ and acknowledged under oath that he is the of �I rnrCe - � of r v the o.�.i;.: named in the attached instrument, and as such was authorized to execute this instrument on behalf of the 4 No ublic: MY codunission Expires: i . JANETTE ELISE WALBY NOTARY PUBLIC OF NEW JERSEY LANDLORD ACKNOWLEDGEMENT MY COMMjSSION EXPIRES FE13.20.20GD INDIVIDUAL ACKNOWLEDGEMENT STATE OF QgW, A OY ) ss: COUNTY OF BE IT REMEMBERED, that on this 4�day of �C. _, 200 j before me, the subscriber, a person authorized'to take oaths.in the State of personally i. appeared Vincent Cannuscio who, being duly sworn on his/her/their oath, deposed and made proof to my satisfaction that he/she/they is/are the person(s)named in the within instrument; and I, having first made known to him/her/them the contents thereof, he/she/they did acknowledge that he/shehliey signed, sealed and delivered the same as his/her/their voluntary act and deed for the'purposes therein contained. Notary Public: My Commission Expires: 1 I lot ,o I ' i I f 4 2005 Form Amendment i EXHIBIT See attached exhibits comprised of 1 page,last revision date 9/15105,prepared by Clough, Harbor&Associates. I I of I 1. This Exhibit may be replaced by a land survey and/or construction drawings of the Promises once it is received by'tenant. 2. Any setback of the Premises from the Property's boundaries shall be the distance required by the applicable governmental authorities. 3. Width of access road shall be the width required by the applicable governmental authorities, including police I andefire departments. 4. The type,number.and mounting positions and locations of antennas and transmission lines are illustrative only. Actual types,'numbers and mounting positions may vary from what is shown above. 2005 Form Amendment i i I �i 1v rfE'MOtTif l W TKL ANAVOMS 167 7 f�Y 'PoIREL uWfflgw JSECXW A i +BRAE ANTENNAS .� y j POLKA lU7TEDRtkS _ TiEkTlt AW101wAS ' � � '7�'B TWUiT i0ihA0111'7 YIIfN > ' ice ?WINPAC101�5 RfL'VMlll♦AD PAOCEJRYE .PVgIE +�E10371NG E.i179"3" 0 -cm*nm&imm pL 3 k It i k iuo xu;� - No WAE VERIZON ANIFEM AS 90'HIGH 1@glOPO:E FGR�11AaMIQIM15 �TOCN. � W a , Tf+,?waft R •Mrt mw xo-srsu oa�rt7r:a. 'ea•aclsaL T ST n 7LE•9R6E o is�7E Um.) E7aSTO+c IMCE0 In rosr OR s Aa POST-'LY •caPOND _ E7BS7MG' 'tr: 'X I .. T,u.0'G:TIONOP iOVfFIMh1{Itl3T iu1Xc txEhR?AEV OF'SOIfR4'hN'4K 9 j,�ry litq,'CAl➢oT TfkVEiV1Y` �25%itF'Rff $' '91RFitf�ARPJ1'AF�A 9f31M,�lkY{E'171OUfl0 TPIE'CPS IINIENNII 2.,U.EFS N;VDMA LOGTR7157 ME To WEMW C"' R ... Q='D afb. A-1�r111116#OtIR SATE lam %toUFI"'1!M ...... 3N71L'IDCA� iF�5 91MkTiNR � ti 1mom nEVAMNS THE iFlbrT'OF4iE•AITBMA'IIRNT'1565•LBS. . ' ��£ i.;(CE�6E'OIt.SMtiW'(MQiOiG�7 iC�iqT 61tGt111®. .p: tAN 94 MC CGW*>?7iNECOPI�t�8E fl�OMdOtiCAICY F •6aVYCD R7 IND•QMtE7C1E0.t NO a gND RDIC. 4 di�TfETI%MGrgemi *q'6d:IS'a1R71I*TLY 9MA!f M 717E.E)CSIois 1U�ER#ID Ti } 1. i P •1dt3L T, �oisekTlai xo'aMtamE TNE: . -1tESE+ TAERCR'nEviElr#rAiP�b'OiYbo'sHoaaTiDT1lE� ..NOSpcE ¢ �mreu��,��.+.ns�RE�a+T a•asrul�ww�v�P�. t'1�'�'#�;.. 91 I '......... ..... _.. rlo-M. �S ae.�, m�AsaT Pmlrl]V i'ilssl/ A ,gwilek. 933C�Cfx%M!itl xis 2i7d2 .. q: 8 a 4 I 3 I . Preria red by—.- Victon�Brennan 3687 Park Avenue Wantagh,NY 11793 Return to: c/o Cingular Wireless 6100 Atlantic Boulevard Norcross,Georgia 30071 ' Attnc Network Real Estate'Administration Re:Cell Site#NYCENY0735; Cell Site Name:Orient Point i State:New Y r County:Suffolk FIRST AMENDMENT TO MEMORANDUM OF LEASE i . This FIRST Amendment to Memorandum. of Lease is entered into on this day of 200�, ;by and between Affordable Housing Associates, Inc. d/b/a Beacon Wireless Management, a New York Corporation, having a mailing address of P.O. Box 303, 27 Oak Lane, Hampton Bays, NY.11946 (hereinafter referred to as "Landlord") and New Cingular Wireless PCS,.LL-C, a Delaware limited liability company,having a mailing address of 6100 Atlantic Boulevard, Norcross, GA 30071 (hereinafter referred to as"Tenant"). 1. Landlord and Tenant entered into a certain NY Structure Lease Agreement ("Agreement") on:the 20'h day of January 2004_, as amended by that certain FIRST Amendment to Agreement for the purpose of installing, operating and maintaining a communications facility and other improvements. A Memorandum of Lease reflecting the Agreement was recorded 200 in Book , page(s) , in the public records of County, State of 2.This First Amendment to Memorandum of Lease is not intended to amend or modify,and shall . not be deemed'or.construed as amending:or modifying,any of the terms,conditions or provisions of the Agreement,.all of.which are hereby ratified and affirmed. In the event of a conflict between the provisions of this First Amendment to Memorandum of Lease and the provisions of the Agreement, the provisions of the Agreement shall control. The Agreement shall be binding upon and inure to the benefit of the parties and their respective heirs, successors, and assigns, subject to the provisions of the Agreement. is IN;WITNESS WHEREOF, the parties have executed this [First,. Second, Third) Amendment to Memorandum of Lease as of the day and year first above written. 2005 Form Amendment i WITNESSES: "LANDLORD" Affordable Housing Associates, Inc. d/b/a Beacon Wireless Management, a New York Corporation Print Name: By. `� Print Name: Prinfi Na e: Vince Cann scio i Its: Date: "� "d► "TENANT" New Cinguiar Wireless PCS,LLC Print Name: a Delaware ited liability company By. Print Name: Print am : James ormann Its: ire for I ple entation(NY/NJ) i . Date: i i 2005 Form Amendment s TENANT ACKNOWLEDGEMENT STATE OF KS ss: COUNTY OF �e� � On the--au day of I10y ,206 before me personally a peared,. us 14Q( jaMd acknowledged under ; oath that he is the of i the -fit named i the attached instrument, d as such was authorized to execute this instrument on behalf of the �rD No blic: My o ission Expires: JANETTE ELISE,11VALB e ' NOTARY PUBLIC OF NEW jEP8F LANDLORD ACKNOWLEDGEMENT pAY COMMISSION EXPIRES FEE.20,2009 INDIVIDUAL ACKNOWLEDGEMENT STATE OF Qxr , 1 ss: COUNTY OF i BE IT REMEMBERED, that on this '81 day of V��- _ a 200S before me, the subscriber, a person authorized to take oaths in the State of tJ,ew personally appeared i,',,�Q, �� uSr►n who,being duly sworn on his/her/their oath,deposed and made proof to my satisfaction that he/she/they is/are the person(s) named in the within instrument; and 1, having first made known to him/her/them the contents thereof,he/she/they did acknowledge that he/she/they signed, i sealed and delivered the same as his/her/their voluntary act and deed for the purposes therein contained. Notary Public My Commission Expires: ak I I ' 2005 Form Amendment 226.00• 1 N W3130■ 1 1 - - I r 1 1 I 1 1 I l \\ 1 \ rwa tm 1 p TAI[lOf \ t1.1 s/ z Ns7,4730°E — I 1 c Iri t 1 sN.rP, -gym 1!P /14 I . I \�'$ Ian/ • p • / rwiw* T�WT u 1 " PJM LANDSURVSYIIdO,PLLC m n.osier e 17 WASHBO TM AVEM18 veAe1 v,D;m Too v r \ .il�T/AVYII.[.!.NY 1179d a,.w.mt:tasa Ua 1d•OtJ�r■���' //fit .cn.waaa sQssr�s..r..aa�4 tary I. .e"ttatm /// PRO I'Y PER ORNA MNT •�` . itnv.no aw,v w a FENAL SURVEf .._......,__ .,..,..__.,..�..�......_..e.. .,._.�,.�... IID%MR RM .Woo a.00 m u v..n.�..�.w..�...rw.t.t.v.w.sw ORIENT FD. •m//. woRwl.t/..,mmoat�l..tl/1.4//Iil.,f t.v w..�,...aw.6 ■�emisw>Atma/sw�tr�rw/to�t�ea��w/a DMWXFM = BY IV SCALE I'■30 A7E11/21A6 ^. � ' ' LYGENY0735 Madcet:FRA 3 Cell Site Number: LI 735 Ceu site Name: Orient point N.Y.STRUCTURE LEASE AGREEMENT THIS LEASE AGREEMENT ("Agreement"), dated as of the date below, is entered into by Affordable Housing Associates,Inc.d/b/a Beacon Wireless Management,a New York Corporation,having a mailing address of P.O. Box 303 27 Oak Lane,Hampton Bays,New York 11946(hereinafter referred to as"Landlord")and Cellular Telephone Company dfb/a AT&T Wireless; having a mailing address of 2729 Prospect Park Drive, Rancho Cordova,CA 95670 (hereinafter referred to as"Tenarrt"). BACKGROUND Whereas,Affordable Housing Associates,Inc.,d/b/a Beacon Wireless Management and The Orient Fire District("Prime Landlord")is the owner of property having a street address of 23300 Main Road(Route 25),located in the Town of Southhold,County of Suffolk, State of New York,and hereafter referred to as the"Property." The Property is more Fully described on Exhibit A attached hereto and made a part of this Agreement. Whereas;Landlord entered into that certain Lease with Prime Landlord dated October 15,2002(the"Prime Lease")whereby Prime Landlord leased 4,000 square feet of the property to Landlord. Landlord desires to lease to Tenant a portion of that certain property,together with all rights and privileges arising in connection therewith,.located at 23300 Main Road (Route 25), in the County of Suffolk, State of New York, Suffolk.County Tax Map Number District 1000-Section 018-Block 5-Lot 13.8,(collectively,the"Properly"). Tenant desires tq use a.portion of the Property in connection with its federally licensed communications business. Landlord desires to grant to Tenant the right to use a portion of the Property in accordance with this Agreement. The parties agree as follows: 1. EL ASE OF PR MISE&; Landlord leases to Tenant portions of the Property consisting of (a) a room/cabinet/ground area space.of approximately Four Hundred Forty Eight(448)square feet; and(b)space on the structure together with such easements as are necessary for the antennas and initial installation as described on attached Exhibit 1(collectively,the"Premises"). Z. PERMITTED USE. Tenant may use the Premises for the transmission and reception of communications signals and the installation,. construction, maintenance, operation, repair, replacement and upgrade of its communications: fixtures and related equipment, with a limit of twelve (12) 7/8"cables, accessories and improvements, which may include a suitable support structure, associated antennas, equipment shelters or cabinets and fencing and any other items necessary to the successful and secure use of the Premises (collectively, the "Communication Facility"), as.well as:the right to test, survey and review title on the Property;Tenant further has the:right to add,, modify and/or replace equipment in order to be in compliance with any current or future federal, state or local mandated application,,including, but not limited to, emergency 911 communication services, at no additional cost to Tenant or Landlord (collectively, the "Permitted Use"). Landlord and Tenant agree that any portion of the Communication Facility that may be conceptually described on Exhibit i will not be deemed to limit Tenant's Permitted Use. If Exhibit 1 includes drawings of the initial installation of the Communication Facility, Landlord's execution of this Agreement will signify Landlord's approval of Exhibit 1. Tenant has the right to install and operate transmission cables from the equipment shelter or cabinet to the antennas, electric lines from the main feed to the equipment shelter or cabinet and communication lines from the main entry point to the equipment shelter C&F/Wc lance i A.Y.swouw 1AW I , or cabinet, and:to make Property improvements, alterations, upgrades or additions appropriate for Tenant's use ("Tenant Changes"). Tenant Changes include the right to construct a fence around the Premises and undertake any other appropriate means to secure the Premises. Tenant agrees to comply with all applicable governmental laws, rules, statutes and regulations,relating to its use of the Communication Facility on the Property. Tenant has the right to modify, supplement, replace, upgrade, expand the equipment, increase the number of antennas or relocate the Communication.Facility within the Premises at any time during the term of this Agreement. Tenant will be allowed to make such alterations to the Property in order to. accomplish Tenant's Changes or to insure that Tenant's Communication Facility complies with all applicable federal,state or local laws, rules or regulations. 3. TERM. (a) . The initial lease term will.be five(5)years ("Initial Term"),commencing upon the Commencement Date, as defined below. The Initial Term will terminate on.the last day of the month in which the fifth(5J')annual anniversary of the Commencement Date occurs. (b) This Agreement:will automatically renew for five(5) additional five (5)year term(s) (each five(5) year torn shall be defined as the "Extension.Term"),upon the same terms and conditions unless the Tenant notifies the Landlord in writing of Tenant's intention not to renew this Agreement at least sixty (60) days prior to the expiration of the existing Term. (c) .If Tenant remains in possession of the Premises after the termination or expiration of this Agreement then Tenant wily be deemed to be occupying the Premises on a month to month basis(the"Holdover Term"), subject to the terms and'conditions of this Agreement. (d) The Initial Term,the Extension Term and the Holdover Term.are collectively referred to as the Term ("Term"). 4. RENT. (a) Commencing upon the earlier of (i) sixty (60) days of Landlord's completion of the legal construction of Landlord's monopole, or(R)on the date that Tenant commences construction (the"Commencement Date");Tenant will pay the Landlorda monthly rental payment of ("Rent"),at the:address set forth above, on or before the fifth(5'h)day of each calendar month in advance. Rent will be prorated for any partial month. The initial Rent payment will be forwarded by Tenant to Landlord within thirty (30)days after the Commencement Date. (b) in year tvyo (2) pf the Initial Term, and each year thereafter, including throughout any Extension Terms exercised;the m . yp"t will increase by over the Rent paid during the previous year. (c) Tenant _ _pay its pro-rata share of expenses incurred by Landlord in connection with Landlord's efforts to obtain local zomjg'#pprovals and building permits directly attributable to the Communication Facility upon presentation of sufficient and proper documentation. The foregoing is only applicable so long as the Landlord chooses the law Mm of Munley,Meade Nielsen&Rd or if Landlord employs the services of Tenant's other approved land use attorney to secure the.necessary governmental approvals for the Communications Facility, such approval shall not unreasonably withheld or delayed by Tenant. S. APPROVALS. (a) Landlord agrees that Tenant's ability to use the Premises is contingent upon the suitability of the Premises for Truant's Permitted.Use and Tenant's ability to obtain all governmental licenses,permits, approvals or other relief required of or deemed necessary or appropriate by Tenant for its use of the Premises, including without limitation applications for zoning variances, zoning ordinances, amendments, special use permits, and construction permits (collectively, the "Government Approvals"). Landlord authorizes Tenant to prepare, execute and file all required applications to obtain Government Approvals for Tenant's Permitted Use under this Agreement and agrees to reasonably assist Tenant with such applications. In addition, Tenant shall have the right to initiate the ordering and/or scheduling of necessary utilities. (b) Tenant has the right to obtain a title report or commitment for a leasehold title policy from a titre insurance company of its choice and to have the Property surveyed by a surveyor of Tenant's choice. In the event C&TAW11 imam 2 R".duos MY.Sbu*m Lana Tenant determines, in its sole discretion,.-due to the title report results or survey results, that the condition of the Premisea,is unsatisfactory,Temnt`will have the right to terminate this Agreement upon notice to Landlord. (c) Tenant may also perform and obtain, at Tenant's sole cost and expense, soil borings, percolation tests, engineering procedures, environmental.investigation or other tests or reports on, over, and under the Property, necessary to determine if the Tenant's use of the Premises will be compatible with Tenant's engineering specifications,system,design,operations or Government Approvals. 6. TERMINATION. This Agreement maybe terminated,without penalty or further liability,as follows: (a) by either:party.on thirty:(30) days prior written notice, if the other party remains in default under Paragraph 15 Default and Right to Cure of this Agreement after the applicable cure periods; (b) by Tenant upon written notice to Landlord, if Tenant is unable to obtain, or maintain,any required approval(s) or the issuance of a license or permit by any agency, board, court or other governmental authority necessary for the construction or operation of the Communication Facility as now and hereafter intended by Tenant; or if Tenant determines in its sole discretion that the cast of obtaining or retaining the same is commercially unreasonable;or (c) by Tenant on sixty(60)days prior w6tten'noticc for any reason,so long as Tenant pays Landlord a termination fee equal to three(3)months Rent,at the then current rate, provided,however,that no such termination fee will be payable on account.of the termination of this Agreement by Tenant under any one or more of Paragraphs 5(b) Approval$, 6(a).Termination,-6(b) Termination, 8 Interference, 11(d) Environmental, 18 Severability, 19 Condemnation or 20 Casualty of this Agreement. 7. IN5URANCE. Tenant will carry during the Term,at its own cost and expense,the following insurance: (i) i "All Risk" property insurance for its property's replacement cost; (ii)commercial general liability insurance with a minimum limit of liability of$2;500,000 combined single limit for bodily injury or death/property damage arising out of any one occurrence; and(iii)Workers'. Compensation Insurance as required by law. It is understood and agreed that 'the coverage afforded by Tomes commercial general liability insurance also applies to Landlord as an additional insured,but only with respect to Landlord's liability arising out of its interest in the Property. 8. INTERFERENCE, (a) Where there are existing radio frequency user(s)on the Property,the Landlord will provide Tenant with a list of all existing radio frequency:user(s) on the Property to allow Tenant to evaluate the potential for interference. 'Tenant warrants that its use of the Premises will not interfere with existing radio frequency user(s)on the Property so disclosed by Landlord as long as the existing radio frequency user(s)operate and continue to operate within their respective fiequencies.and in accordance with all applicable laws and regulations. (b) Landlord will not.grant, after the data of this Agreement, a lease, license or any other right to any third party for.the use of the Property, if such use may in any way adversely affect or interfere with Tenant's Communication Facility. Landlords will notify Tenant in writing prior to granting any third party the right to install and operate communications .equipment on the Property.. Nothing contained herein will restrict Tenant nor its successors and assigns from installing and modifying its communications equipment. (c) Landlord will not use, nor will Landlord permit its employees,tenants, licensees, invitees or agents to use,any.portion of the pporty in any way which interferes with the operations of Tenant or the rights of Tenant under this Agreement: Landlord will cause such interference to cease within.tweuty-four(24)hours after receipt of ;notice of interference.from Tenant. Itn the event any such interference does not cease within the aforementioned cure poriod then the parties acknowledge that Tenant will suffer irreparable injury, and therefore, Tenant will have the right, in addition to any other rights'that it may have at law or in equity,for Landlord's breach of this Agreement,to elect to enjoin such interference or to terminate this Agreement upon notice to Landlord. 9. INREMIFICATION. (a) Tenant agrees to indemnify, defend and hold Landlord harmless from and against any and all injury, :loss,damage or liability(or any claims in respect of the foregoing),costs or expenses(including_reasonable attorneys' N.Y.saun,ae 3.eaa.; fees and court costs)arising directly from the installation,use,maintenance, repair or removal of the Communication Facility.or Toads breach of any provision of this Agreement, except to the extent attributable to the negligent or intentional act or omission of Landlord,its employees,agents or independent contractors. (b) Landlord agrees�to indemnify, defend and hold Tenant harmless from and against any and all injury, loss,damage or liability(or any claims in respect of the foregoing),costs or expenses(including reasonable attorneys' fees and court costs) arising directly from the actions or failure to act of Landlord or its employees or agents, or Landlord's breach of any provision of this Agreement,except to the extent attributable to the negligent or intentional act or omission of Tenant,its.employees,agents or independent contractors. (c) Notwithstanding anything to the contrary in this Agreement, Tenant and Landlord each waives any claims that eachmay have against the other with respect to consequential,incidental or special damages. i 10. VY NTIES. (a) Tenant and Landlord each acknowledge and represent that it is duly organized,validly existing and in good standing and has the right,power and authority to enter into this Agreement and bind itself hereto through the party set forth as signatory for the party below. (b) Landlord represents.and warrants that: (i)Prime Landlord solely owns the Property as a legal lot in fee supple,or controls the Property and structure by lease or license;(H)the Property is not encumbered by any liens, restrictions,mortgages,covenants, conditions,easements,leases, or any other agreements of record or not of record, which would adversely affect Tenant's Permitted Use and enjoyment of the Premises under this Agreement; (iii) as long as Tenant is not in default then Landlord grants to Tenant sole, actual, quiet and peaceful use, enjoyment and possession of the Premises; (iv) Landlord's execution and performance of this Agreement will not violate any laws, ordinances,covenants or the provisions of any mortgage,lease or other agreement binding on the Landlord;and(v)if the Property is or becomes encumbered by a deed to secure a debt,mortgage or other security interest, Landlord will use best efforts to provide promptly to Tenant a mutually agreeable Subordination,Non-Disturbance and Attornment Agreement. 11. ENVRO MN ,NTI+ AL, (a) `Landlord represents;and warrants that the Property is free of hazardous substances as of the date of this Agreement:,:and, to the best of Landlord's knowledge,the Property has never been subject to any contamination or hazardous conditions resulting in any environmental investigation, inquiry or remediation. Landlord and Tenant agree that each will be responsible:for compliance with any and all environmental and industrial hygiene laws, including any regulations, guidelines, standards, or policies of any governmental authorities regulating or imposing standards of.liability or standards of conduct with regard to any environmental or industrial hygiene condition or other matters as may now or at any,time hereafter be in effect,that are now or were related to that parry's activity conducted in;of on the Property. (b) Landlord.and Tenant agree to hold harmless and indemnify the other from,and to assume all duties, responsibilities and liabilities at.the sole cost and expense of the indemnifying party for, payment of penalties, sanctions,'forfeitures, losses, costs,'or damages, and for responding to.any action, notice, claim, order, summons, citation, directive, litigation,.investigation or proceeding which is related to (i) the indomifyin8 parry's failure to comply with any environmental or industrial hygiene law, including without limitation any regulations, guidelines, standards or policies of any governmental authorities regulating or imposing standards of liability or standards of conduct with regard to any environmental or industrial hygiene conditions or matters as may now or hereafter be in effect, or (ii) any environmental or;industrial hygiene conditions that arise out of or are in any way related to the condition of O Property and activities.conducted by the party thereon, unless the environmental conditions are caused by the over party. (c) The indemnifications of this Paragraph H Environmental specifically include reasonable costs, expenses and fees incurred in connection with any investigation of Property conditions or any cleanup,remediation, removal or restoration work required by any governmental authority. The provisions of this Paragraph 11 Environmental will survive the expiration or termination of this Agreement. carom:3sxua ¢ $w.11103 N.Y.Suuuum Gage i (d) In the event Tenant becomes aware of any hazardous materials on the Property, or any .environmental.or industrial hygiene condition or matter relating to the Property that, in Tenant's sole determination, renders the condition of the Premises or Property unsuitable for Tenant's use,or if Tenant believes that the leasing or .continued leasing of'the Premises: would,expose Tenant to undue risks of government action, intervention or third-party liability, Tenant will have the right, in addition to any other rights it may have at law or in equity, to terminate the Agreement upon notice.to Landlord. i 12. ACCE,S$, At all times throughout the Term of this Agreemem, and at no additional charge to Tenant, Tenant and its;employees, agents, and subcontractors, will have twenty-four (24) hour per day, seven (7) day per week pedestrian and vehicular access to and over the Property, from an.open and improved public road to the Premises, for the installation, maintenance and operation of the Communication Facility and any utilities serving the Premises and Landlord grants to Tennant an easement for such access. Upon Tenant's request, Landlord will execute a separate recordable easement evidencing this right. In the event any public utility is unable to use the access or easement provided to Tenant then the Landlord agrees to grant additional access or an easement either to Tenant or to the public utility,for the benefit of Tenant,at no cost to Tenant. 13. REMQVAL/REST RATIQM AU portions of the Communication Facility brought onto the Property by Tenant will be and remain Tenant's personal property and,at Tenant's option,may be removed by Tenant at any time during the Term. Landlord covenants and agrees that no part of the Communication Facility constructed, erected or placed on the Premises by Tenant will Become,or be considered as being affixed to or a part of,the Property,it being the specific intention of the Landlordthat all improvements of every kind and nature constructed,erected or placed by i Tenant on the Premises will be and remain the property of the Tenant and may be removed by Tenant at any time during the Term. Notwithstanding the:foregoing, at the earlier of the expiration or termination of this Agreement, Tenant will not be responsible for the replacement of any trees, shrubs, or other vegetation, nor will Tenant be required to remove from the Premises: or the Property any foundations, underground utilities, or any part of the Comrnunicatio> Facility. 14. MAINTENANCF& 76ILITIES. (a) Tenant will keep and maintain the Premises in good condition,reasonable wear and tear and damage from the elements excepted. Landlord will maintain and repair the Property and access thereto, in good and tenantable condition,subject to reasonable wear and tear and damage from the elements. (b) Tenant will be responsible. for paying on a monthly or quarterly basis all utilities charges for electricity, telephone service or any other utility used or consumed by Tenant on the Premises. In the event Tenant cannot secure its own metered electrical supply,Tenant will have the right,at its own cost and expense,to submeter from the Landlord. When submetenng is necessary and available, Landlord will read the meter on a monthly or quarterly basis and provide Tenant:with the necessary usage data in a timely manner to enable Tenant to compute. such.utility charges. Failure by Landlord to perform this function will limit utility fee recovery by Landlord to a 12- month period. landlord will fully cooperate with any utility company requesting an easement over,under and across the Property in:order for the utility company to provide service to the Tenant. Landlord will not be responsible for interference with, interruption of'or failure, beyond the reasonable control of Landlord, of such services to be fiunished or supplied by Landlord. 15. DEFAULT AND'ffigHT IQ QM. (a) 'The following will be deemed a default by Tenant and a breach of this Agreement: (i)non-payment of Rest if such:Rent remains unpaid for more than thirty(30)days after receipt of written notice from Landlord of such failure to pay;or(ii)Tenant's failure to perform any other term or condition under this Agreement within forty- five(45)days after receipt of written notice from Landlord specifying the failure.No such failure,however, will be deemed to exist if Tenant has commenced to cure such default within such period and provided that such efforts are prosecuted to completion with reasonable diligence. Delay in curing a default will be excused if due to causes beyond c�r�w,»ssus S Rev.VIIM N.Y.ftwa o LWO the reasonable control of Tenant. If Tenant remains in default beyond any applicable cure period,Landlord will have the right to exercise any and all rights and:remedies available to it under law and equity. (b) 'The following will;be deemed a dc&ult.by Landlord and a breach of this Agreement. Landlord's failure to perform any team, condition or breach of any warranty or covenant under this Agreement within forty-five (45)days after receipt of written notice from Tenant specifying the failure. No such failure,however,will be deemed to exist if Landlord has commeaced to cure the default within such period and provided such efforts are prosecuted to completion with reasonable diligence. Delay in curing a default will be excused if due to causes beyond the reasonable control of Landlord..'If Landlord remains in default beyond any applicable cure period,Tenant will have the right to exorcise,any and all rights available to it under law and equity, including the right to cure Landlord's default and to deduct the costs of such cure from any monies due to Landlord by Tenant, 16. ASgIMNT/SUBL W E. Tenant will have the right to assign this Agreement or sublease the Premises and its rights herein, in whole or in.part, without Landlord's consent. Upon notification to Landlord of such future perfannance,liabilities and obligations under this Agreement. assignment,Tenant will be relieved.of all 17. NOT-ICU, All notices, requests, demands and communications hereunder will be given by first class certified or registered mail,return receipt requested,or by a nationally recognized overnight courier,postage prepaid, to be effective:when properly sent and received, refused or returned undelivered. Notices will be addressed to the . parties as follows: If to Tenant: AT&T Wireless i Atta.: Lease Administration Re: AWS Cell Site#:LI-735;Cell Site Name: Orient Point I 2729 Prospect Park Drive Rancho Cordova;CA 95670 with a copy to:; AT&T Wireless Attn.: Legal Department Re: AWS Cell Site#:LI-735 Cell Site Name: Orient Point 15 East MidlandAvenue Paramus,NJ 07652 If to Landlord:: Affordable.Housing Associates,Inc.d/b/a Beacon Wireless Management P.O. Box 303 27 Oak Lane Hampton Hays,New York 11946 Either party hereto may change the place for the giving of notice to it by thirty(30)days written notice to the other as provided herein.. 18. SEYERAHILTV; If any,term or condition of this Agreement is found unenforceable,the remaining terms and conditions:will.remain binding upon the parties as though said unenforceable provision were not contained herein, Howcver, if the .invalid, illegal or unenforceable provision materially affects this Agreement then the Agreement may be terminated by either party on ten(10)business days prior written notice to the other party hereto. 19. EMN TION. In the event Landlord receives notification of any condemnation proceedings affecting the Property, Landlord will provide.notice of the proceeding to Tenant within forty-eight(49)hours. If a condemning authority takes all of the Property, or a portion.sufficient, in Tenant's reasonable determination, to render the Premises unsuitable for Tenant, this Agreement will terminate as of the date the title vests in the condemning authority. The parties will each be entitled to pursue their own separate awards in the condemnation proceeds,which ce►raw ss�sua 6 Pa.trim N.Y.SW4d=Lem i for Tenant will,inckude, where applicable, the value of its Communication that Facility,moving expenses, prepaid Rent, and business.dislocation expenses,.provided any award to Tenant will not diminish Landlord's recovery. Tenant will be entitled to reimbursement,for:any prepaid Rent on a prorate basis. 20. CASUALTY] Landlord will provide notice to Tenant of any casualty affecting the Property within forty- eight(48)hours of the casualty. If any part of the Communication Facility or Property is damaged by fire or other casualty so as.to render.the Promises unsuitable, in Tenant's sole determination, then Tenant may terminate this Agreement by providing written.notice to-the Landlord, which termination will be effective as of the date of such damage or destjruction. Upon such termination, Tenant will be entitled to collect all insurance proceeds payable to Tenant on account thereof and.to bereimbursed for any prepaid Rent on a prorata basis. 21. WAIVER OF LANDLORD'S LIENS. Landlord waives any and all lien rights it may have, statutory or otherwise, concerning the Communication Facility or any portion thereof. The Communication Facility shall be deemed personal property for purposes.of this Agreement, regardless of whether any portion is deemed real or personal property under applicable law, and.Landlord consents to Tenant's right to remove all or any portion of the Communication Facility from time to time in Tenant's sole discretion and without Landlord's consent. 22. MISCELLANkrW (a) ` AmendanentlWaiver. This Agreement cannot be amended, modified or revised unless done in writing and signed by an authorized agent of the Landlord and an authorized agent of the Tenant.No provision may be waived except in a writing signed by both parties. (b) Memorandum/Shorrt Form Lease. Either party will, at any time upon fifteen(15) business days prior written notice from the other, execute,acknowledge and deliver to the other a recordable Memorandum or Short Form of Lease.. Either party may.:record this Memorandum or-Short Form of Lease at any time, in its absolute discretion. (e) Bind and Benefit. The terms and conditions contained in this Agreement will run with the Property and bind and inure to the benefit of the parties, their respective heirs, executors, administrators, successors and assigns. (d) Entire Agreement. This Agreement and the exhibits .attached hereto, all being a part hereof, constitute the entire.agreement of the.parties hereto and will supersede all prior offers, negotiations and agreements with respect to the subject matter of this Agreement. (c) : Governing Law. Thus Agreement will be governed by the laws of the state in which the Premises are located,without regard to conflicts of law. M .Interpretation. Vuless.*otherwise specified, the following rules of construction and interpretation apply; (i)captions are for convenience and reference only and in no way define or limit the construction of the terms and conditions hereof;.(ii)use'of the term"including" will be interpreted to mean"including but not limited to'; (iii) whenever a party's consent is required-under this Agreement,except as otherwise stated in the Agreement or as same may be duplicative, such consent will not be unreasonably withheld, conditioned or delayed; (iv) exhibits are an integral part of the Agreement and are incorporated by reference into this Agreement; (v) use of the teams "termination or "expiration" are.interchangeable; and (vi) reference to a default will take into consideration any :applicable notice,grace.and`enre.pe.iods. (g) Estoppel. Either party will, at any time.upon twenty (20).business days prior written notice from the other, execute, acknowledge and deliver to the other a statement in writing (i) certifying that this Agreement is unmodified and in fu11 farce.and effect (or, if modified,-stating the nature of such modification and certifying this Agreement, as.so modified, is in full force and effect) and the date'to which the Rem and other charges are paid in advance; if any,.and (it) acknowledging that there are not, to such party's knowledge, any uncured.defaults on.the part of the other party hereunder, or specifying such defaults if any are claimed. Any such statement may be conclusively relied upon by any prospective purchaser or encumbrancer of the Premises. The requested party's failure to deliver such a statement:within such time will be conclusively relied upon by the requesting party that(i) this Agreement. is in full force and effect, without modification except as may be properly represented by the craws 323MI' 7 Rev,11103 N.Y.Structure Lore i j r 's requesting party, (H)there are no uncured defaults in either patty's performance, and(iii)no more than one month Reat has been paid in advance. (h) No Electronic 'Siguature o Option. The submission of this Agreement to any party for examination or;consideration'does not constitute an offer,reservation of or option for the Premises based on the terms set forth herein. This Agreement will become effective as a.binding Agreement only upon the handwritten legal execution,acknowledgment and delivery hereof by Landlord and Tenant. 23. TAXES. Tenant will.pay all personal property taxes assessed on,or any portion of such taxes attributable to,the Commuf uication Facility upon presentation of sufficient and proper documentation. [SIGNATURES APPEAR ON THE NEXT PAGE.] i i CAF&W,3=03 8 Itev.l/IN3 N.Y.SIMQU=L=M IN WITNESS WHEREOF, the parties have caused this Agreement to be effective as of the last date written below. WITNESSES "LANDLORD" AFFORDABLE HOUSING ASSOCIATES,INC. Print Name; D/B/A BEACON WIRELESS MANAGEMENT By. + U/ Print Name: Print ame: Vin t C scio Its: President Date: "TENANT" CELLULAR TELEPHONE COMPANY D/B/A AT&T LESS Print Name: V By: Print Name: Print N o p Sweet Its:System eI m M er Date: [ACKNOWLEDGMENTS APPEAR ON THE NEXT PAGE.] carawssiusz 9 Rev.1/1/03 N.Y.Shw*"Late MOT A!2jQ XD—GMENT STATE OF 1 RAI _ 1 ss: COUNTY OF . On the y of in a yearr�Oa before me,the undersigned,a notary public in and for said state, personally appeared rsonally known to me or proved to me on the basis of satisfactory evidence to be the in ' 'du (s)'whose name(s)is(are)subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their capacity(ies),and that by his/her/their signature(s)on the instrument,the.indhgdual(s)or the person upon behalf of which the individual(s)acted,executed the instrument. Notary&QK My Commission Expires: LAWRENCE C. RE LANDLORD ACKN„(�WLEDGMENT Notary Public,State of New York No. 52-A799664 Qualified in Suffolk Courrayy ��,,� d �J Commission Expires May 31; 5L1 STATE OF /L/�- ss: COUNTY OF On th�f.�day of in the yeadw before me,the undersigned,a notary public in and for said state, personally appear fi&?lrlb„6JVSd# .personally known to me or proved to me on the basis of satisfactory evidence to be the individual(s)whose name(s)is(are)subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/herhheir capacity0es),and that by his/her/their signature(s)on the instrument,the'individual(s)or the person upon behalf of which the individual(s)acted,executed the instrument. Notary Public: My Commissi xpires: filalMY � Cep M k. c&FAws ssseus ld 'Aay.111103 N.Y.8nwtureLa+a EXHIBIT A Property Description 23300 Main Road(Route 25),Orient Point,New York Suffolk:County Tax Map: District-1000 Section-01.8 Block-5 Lot-13.8 BEGINNING at the mterseetion of the southerly line of Main Road with the easterly line of Tabor Road and running along saidsoutherly line of Main Road,north 80 degrees 10 minutes east 228.0 feet; 'I'I>ENCEFalong land of Ferreira two courses(1)south 9 degrees 50 minutes cast 150.0 feet; THENCE'(2)north 80 degrees 10 minuets East 91.47 feet; THENCE.along land of Gloria South 21 degrees 41 minutes east 5.43 feet; THENCE continuing along land of Gloria and along land of Wernikowsid,north 78 degrees 02 minutes 40 seconds-cast 120.38 feet to a monument and land of William Y.Terry,Jr., THENCE along land of Orient Central Cemetery two courses: (1) 'South$2 degrees.42 minutes 20 seconds west.519,10 foot to the easterly line of Tabor Road; THENCE along said line of Tabor Toad two courses(1)north 0 degrees 59 minutes 30 seconds west 652.77 feet; THENCE(2)north 5 degrees 00 minutes 30 seconds west 116,75 feet to the point or place of BEGINNING, i. N.Y.Slnlatute 1.�0 EXHIBIT 1 DESCRIPTION OF PREMISES Page 1 of 4 ta.tW Agreement datWcU9— `ZOgf,by and between Affordable Housing Associates, Inc.d/b/a Beacon Wireless Management,a New York corporation,as Landlord,and Cellular Telephone Company.d/b/a AT&T Wireless,a New York general partnership,as Tenant. The Property is described and/or depicted as follows: A 448 square foot section of land located within 23300 Main Road(Route 25),Orient Point,New York Suffolk County Tax.Map: District 1000 Secction-.018 Block-5 ' Lot-13.8 Notes: 1. This Exhibit maybe replaced by a lend survey and/or coaMucdon drawings of the Pre Wm once mAved by T 2. Any aeiback ofihe Premim Brain the Property's bouadades aha11 lie tha diomwe npirad by the applicable govemmental authorities. cc 3. Width of access mod aladl be tha width iegi"by the applicable goverrMwW autharMok including police and fat deparhnerds. 4. 11w type,ntanber and mottling positions and locations of wimmaa and traaaminion linos arc illustrative only.Actual types,numbers and mouaditrgpoaitionsmay vary$tom wh+a is abown above. i r&W,asaaua N.Y.Sftchm UAW L EXHIBIT 1 Page 2 of 4 RoAU + 'E,2o, NOW OR FORMALLY LANDS {r LUDIYH KaFERRRA P 47=*E..— _—•--� EMSTING BRICK FIREHOUSE i 7tl EMISTiNO METAL aUILom E>45T1NO n E)QSTINO ASPHALT CON SLABAB PROPOSED U DRIVEWAY FENCE (BY OTHERS) rEXISTING LAWN AREA PROPOSED (/ 1217 FLAGPOLE TYPE MONOPOLE (BY OTHERS) E �i PROPOSED sly Q�1�OOOMMPOUND (BY OTHERS) NOW OR FORMALLY LANDS OF N/0/F SCHNEYER I 1 SITE PLAN 4RAPHIC BCAL� ' f NOTE.ROPOsro AT&T.WIRELESS INSTALLATION SHOWN 19 ONLY APPROXIMATE: OW-LOCATIONS AND DETAILS WILL BE OETERMINED Of FRAL ENGINEERINR OESIGN. EH:; AWS#IJ-735 ' OF 3 . ~T&T 23300 MAIN ROAD o1ur110 I o� Rav 1 . CL,CUGK HA ■OLM AnYwl :eaaNa°�,�XL , a A080CI LLP 16 c!>It16A►D AVE,P na am ORIENT POINT, NY 11957 01tNRp4L OYNAMIQ■ LE-1 I Ke ra»� �rMM/.>YIw4tr�Ylww�PMlr 04A pit" NO. - IXW-3= 11 ib E 1MOLIID AVR..PAAAIItN,NJ 0706� mOwN D 1 N-1m No mmmm 9'1.6M 0-m 11/10/m 120 7Y EXHIBIT I A ya4°x'. 4 ON page 3 of 4 PRA�10LSiEl7 AMPS AE71R ATTAMAW ELECTRICAL TO BACKBOARD TRANSFORMER AND VAULT FUTURE 4-GANG METER BOARD FUTURE U URE 1 OONCRETE PAD FUTURE i CSC CABINET fUIURE 12' ACCQSS GALE ( . PR01°IOM AM FUTURE UNMM fW POW? FARRIER AW TF.LG10 �� � { Pfia0a M AMJI` Ax:6V1 47 I � FUTURE T-MOBILE ICE BRIDGE FUTURE 6'BLACK VINYL FENCE ! UTURE FUTURE 50'X50'* 2'O. �.- I CARRIER FENCED COMPCUND f AWPOSM AM5 1691'2B'LEASE AREA , FUTURE 120' TALL �I FLAGPOLE MONOPOLE S13E PLAN awmc SCU 0 1 0 i NOTEI OSED AT&T WIRELESS INSTAIIATION SHOWN IS ONLY ��ppppROIQMATfi EXACT LOCA710NB'AND DETAILS WILL BE OL�1ERkiINEO BY FlNAL ENGINEFFINO DESIGN. eH _ AW8#LI-735 °� 3 �,40M„ AT&T 23300 MAIN ROAD c>`.cwor+. H� MO �TnYwsoemncee.>INo. 6iA®iiOC1A !!+s 1.1.P 15 C WOLND AVL PARAM16 MJ 07ib8 ORIENT POINT, NY 11957 O1�NigAL.DY1VAMtG• LE-2 III N�NMp1t GIIO.R �11NMM 11MIIMMIr11Y11 .> � 011A PROD. N0. 1A0/4�7020 �uru+r.yr uaw 16&MIDLAND ME.,PARAMN,IN 0760Z i Rb momtM WPb�lowwwom 0u-=)OtW Ph1Y[�.1E0 -2%j Ilrw:�If/11/=114 VW FUTURE T-11OBILE ANTENNAS EXHIBTf'1 Page 4 of 4 BS/N1L74'NALLY MOViV7ED FUTURE CARRIER 3 ANTENNAS FUTURE FIRE AND POLICE ANTENNAS SEC7t�7 A 0 ANs AN7AVNA5 A fa9-0'AM o 8 MONOPOLE OFLAGPOLE SWER C �' SEDTA4 B �0. 120 5 Qi ANTENNA ORIENAMObt NO SCALE t• F i I 120' HIGH FLAGPOLE MONOPOLE PRWOS7ED.Ails LEASE'MX R'--W HIGH BLACK VINYL FENCE I i , EXISTING T-MOBIL STS UNIT V ' TOWER ELEVATfON NO $CALF NOM PROPOSM AT&T WIRELESS INSTA.LA N SHOWN IS ONLY OETERALINED BY FINAL E1401NRMNC MOO pD GNl8.WILL BE 3t OF C AWS#U-735 E---' AT&T 23300 MAIN ROAD Rev f ` a e►N�GCIATlL L� FAUrVArAlm AN'w PARAIN Nd 6760 ORIENT POINT, NY 11967 `� OiNa<RAI.OYNAMIO� LE-3 nl MNMfAs QhcsX L I is&WNW* N A PYC�1i�Q7�bs CM FlWJ. 19L Ma1WY N7"IR FIN II%Owwd OIIw�I WAV=OJ-74 OW— U�r 9pI 11/1I=12M PH MEMORANDUM OF LEASE [FOLLOWS ON NEXT PAGE] Pret�a�. retl btr. l�i� :�Sr,�s�r��s /mac• d i r u s -}d IOND Adn-y AT&T Wireless CftO C'gz- V/f, C Ce11 S,igNo.:LI-735 Statc:New York County:Su" CAY&W:123841.E N.Y.BhuchimlAw MEMORANDUM OF LEASE "'" of 20b and between This Memorandum of Lease is entered into on this .�� day �� Y Affordable Housing Associates,Inc;d/b/a Beacon Wireless Management,a New York corporation,having a mailing address of P.O. Box 303, 27 Oak Lane, Hampton Bays, New York 11946-(hereinafter referred to as "Landlord") and Cellular Telephone Company d/b/a AT&T Wireless, a New York general partnership,having a mailing address of 2729 Prospect Park Drive,Rancho Cordova,CA 95670(hereinafter referred to as"Tenant"). 1. Landlord and Tenant entered into a certain Lease Agreement C`Agreement") on the day of G .AN l' , 206 for the purpose of installing, operating and maintaining a communications facility and other improvements, All of the foregoing are set forth in the Agreement. 2. The term of the Agreement is for an Initial Term of five(5)years commencing on the date that Tenant commences construction and ending on the last day of the month in which the fifth(5th)anniversary of the Commencement Date occurs,with five(5)successive automatic five(5)year options to renew. 3. The portion of the land'being leased to Tenant(the"Premises")is described in Exhibit A and Exhibit 1 'annexed hereto. 4. The Agreement shall be binding upon and inure to the benefit of the parties and their respective heirs, successors,and assigns,subject to the provisions of the Agreement. �I CAF4M 32300.2 i IN WITNESS WHEREOF,the Parties have executed this Memorandum of Lease as of the day and year first above written. WITNESSES: "LANDLORD" AFFORDABLE HOUSING ASSOCIATES,INC DB/A BEACON WIRELESS MANAGEMENT Print Name: f —� By: V Prim Name Print Name: Vincent Cann cio residenRU,`AlDate o "TENANT" CELLULAR TELEP ONE COMPANY DB/A AT ZT WIRE SS Print Name By: Print Name: Print Nam : h S Its:System a Pm Date. NJ O ' 4 I ' TENANT ACKNOWLEDGMENT STATE OF ss: COUNTY OF On the'z� y of in a yearjV4 before me,the undersigned,a notary public in and for said state, personally appeared rsonafty known tome or proved tome on the basis of satisfactory evidence to be the individual(s)who e(s)is(are)subscribed to the within instrument and acknowledged to me that he/sheJthey executed the same in his/her/their capacity(ies);and that by his/her/their signature(s)on the instrument,the individual(s)or the person upon behalf of which the individuals)acted,executed the instrument, Notary blic: My Commission Expires: LAWRENCE C. RE' Notary Public,State of New York LANDLORD ACK (0WLgRGMENT No, 52-4799664 Commission Expir in es Suffolk 31 STATE OF t ) ss: Slut 624/� COUNTY OF On 42Z&W_jb in the yeal&before me,the undersigned,a notary public in and for Said state, personally appear ed personally known to me or proved to me on the basis of satisfactory evidence to be the individual(s)whose nasne(s)is(arc)subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their capacity(ies),and that by hisiber/their signature(s)on the instrument,the individual(s)or the person upon behalf of which the individuals)acted,executed the instr went. Own drA Notary P . My Commission Expires: . C �Otk HOW i csrsws s:s�ua EXHIBIT A Property Description 23300 Main Road(Route 25),Orient Point,New York Suffolk Count*Tax Map: District-1000 Section-018 Block-5 Lot-13.8 BEGINNING at the intersection of the southerly lute of Main Road with the easterly line of Tabor Road and naming along said southerly line of Main Road,north 80 degrees 10 minutes east 228.0 feet; THENCE alonO land of Ferreira two courses(1)south 9 degrees 50 minutes east 150.0 feet; THENCE(2)north 80 degrees 10 minuets East 91.47 feet; THENCE along land of Gloria South 21 degrees 41 minutes east 5.43 feet; THENCE continuing along land of Gloria and along land of Wernikowski,north 78 degrees 02 minutes 40 seconds east 120.38 feet:to a monument and'land of William X.Terry,Jr., :THENCE along land of Orient:Centml Cemetery two courses: (2) South 82 degrees 42 minutes 20 seconds west 519.10 feet to the easterly line of Tabor Road; THENCE along said line of Tabor Toad two courses(1)north 0 degrees 59 minutes 30 seconds west 652.77 feet; THENCE(2)north 5 degrees 00 minutes 30 seconds west 116.75 feet to the point or place of BEGINNING. 14V EXHIBIT 1 EXHIBIT A Property Description 23300 Main Roan.(Route 25),Orient POlnt,New York Suffolk County Tax Map: District-1000 Section-018 Block-5 Lot-13.8 BEGINNING at`the intersection of the southerly line of Main Road with the easterly line of Tabor Road and mmnmg along said southerly line of Main Road,.north 80 degrees 10 minutes east 228.0 feet; THENCE alongiland of Ferreira tvyocourses(1)south 9 degrees 50 minutes east 150,0 feet; THENCE(2)north 80 degrees 10 miuuets East 91.47 feet; i THENCE along land of Gloria South 21 degrees 41 minutes east 5.43 f=4 THENCE continuing along land of Gloria:and along land of Wernikowski,north 78 degrees 02 minutes 40 seconds east 120.38 feet to a monument and.land of William Y.Terry,Jr., THENCE along land of Orient Central Cemetery two courses: (2) South 82 degrees 42 minutes 20 seconds west 5 19.10 feet to the easterly line of Tabor Road; THENCE along said line of Tabor Toad two courses(1)north 0 degrees 59 minutes 30 seconds west 652.77 feet; THENCE(2)north 5 degrees 00 minutes 30 seconds west 116.75 feet to the point or place of BEGINNING. aV C&V&W:92M&2 EXHIBIT 1 DESCRIPTION OF PREAUSES Page 1 of 4 to the Agreement dated --7"4Wv~ q"loot,by and between Affordable Housing Associates,Inc.d/b/a Beacon Wireless Management,a New York corporation,as Landlord,and Cellular Telephone Company d/b/a AT&T Wireless,a New York general partnership,as Tenant. The Premises are described and/or depicted.as follows: A 448 square foot section of land located within 23300 Main Road(Route 25),Orient Point,New York Suffolk County Tax Map: District-1000 Section-018 Block-5 Lot-13.8 j ' cakvaw s�xus i EXHIBITPop 2 41 6 NOW OR FORMALLY LANDS OF FRANCIS a A Q 1,, JUDITH K FERRIRA P rill E)uSTINO BRICK O FIREHOUSE EX"N0 METAL • � BUILONiO COSTING I ASPHALT CONCRETESLAB ORIYEWAY PROPOSED FEENCE (BY OTHERS) rE%IS71NG LA1Ni AREA PROPOSED 1(/ 12W FLAOPOLE TYPE MONOPOLE r : (ev OTHERS) i PRFOP Be NCEDD 0 MPOUND (BY OTHERS) B3ro�'60�w NOW OR FORMALLY LANDS OF N/O/P SCHRIEYER i SITE PLAN GRAPHIC SCE yv 0 s!O 1 NOTE, ; PROPOM AT&T WMEIESS.INSI'ALLATION SHOWN 19 ONLY APPRO)OWME. 9KT:LOCATI0NS ANO DETAILS WILL BE DETERMINED BY FINAL EWWEERIN0.0ESI0N. or c AT&T Aws#LI-735 23300 MAIN ROAD RLV . Cf•CaUOiH..H OL1A ATfiT WII{QLl�i�RView LAIM a,a��oc�Ak L.LIP U L MWMD AVL.PARAINI/,xJ 07Mf� ORIENT POINT, NY 11957 is frxxues alias wr�w AlwMrrMlAna 1�fa o1N rRaJ. xo. — +�—Soio auwNv.,Nr naoa 10 4 1MOGND AYE..PAAA""I 07lt6i ►rs w�wwr nriaa�tgVlfi�ss�VR.dano pr7m orra arqu�mo-a-t.�w wn ss n/+enaoy+rmr w is A�RaX, EXREBIT 1 J A Page 3 Of 4 PRAM AM MEM?ArTACHM ELECTRICAL ?V BALW80ARD TRANSFORMER AND VAULT FUTURE 4-GANG METER BOARD FUTURE 10'X20' T-MOBILE CONCRETE PAD FUTURE CSC CABINET FUTURE 12' ACC9SS WE I PRO116 AM I CARRIER 19 ( i/IY EM�401/IVD PDlIM ANa 1a co:LL�WlX1/15 —FUTURE BR T-MOBILE ICEGE FUTURE 5' BLACK f ---- VINYL FENCE' FUTURE WXSO': 2!-Cf ( FUTURE FENCED COMPOUND CARRIER PRAP0.w AW 16:Y21?'LEASE AREA FLAGPOLE MONOPOLE ATE PLAN GReMC SCE io 1 I (>M v NOTE: PROPOSED AT&T WIR< WITA"TION SHOWN IS ONLY APPROXIIU► - Na, LWArONS.AND DETAILS WILL BE OE71d IMED OY FINAL,DwINEERINO DESIGN. i OR a"EH IIiT&T Aws#LI-735 ' " 23300 MAIN ROAD R� c�.ouat�CA TA �T+wrvri�I.eee>o :�o. I 8 AAa0CATTA u.P 18 E' Avt,PARANU Nr mean ORIENT POINT, NY 11967 ammot.mAt.4YNAMIGN LE»2 10%*NWA, a MiNdi�Aillwlkwilliu r 4 cm MM. No. - 19d��-AOZo Auutr,Nr:i w to G fit1L L AMs PARAMf4 NJ 076flQ i ire 16ma*A doVIiR11mCu mm 5-m 6-PWA4n1Q0-W-I w ur ti/ie/'ims Im m FUTURE.T—MOSILE ANTENNAS EXHIBIT 1 Page 4 of 4 PROPOSED A06 ANM WVAS TO BE%MMMALL Y A/OGW IFD i FUTURE CARRIER 3 ANTENNAS FUTURE FIRE AND POLICE ANTENNAS SECTOR A AIDS ANTENNAS a 0' A 1081-00 AOL FUTURE 120E TALL < MONOPOLE FLAGPOLE F is No SCALE I � F. t � i 120' HIGH FLAGPOLE MONOPOLE PRAM AM LEAJgr SPAGE 6'-0" HIGH BLACK VINYL FENCE i &STING T—MOBIL STS UNIT No.SCALE NOTEF FRDFOSEA.AT&T WEiEIfSS I►d$TACLJ1TloN AILS W 1L E APPROA TE. DIACi LOCATIONS AND DETAILS MAIL BE OEM INEC BY FINAL ENCINEERING;DWQ �AWS#Ll- ' of 1 EH- AT&T 23300 MAIN ROAD Rev 1 CLo1J01N: LiARS NR. ATIeTWiI �lEAVIt .ID10. w wlr�ociATr� I6 6 iMOWS AVL#PARAIAlk NJ 07M ORIENT POiN7, NY 11957LE-3 4R11L ar {iiA PVNAMION m uw w- or+f.w00 Mom" cm Phu. �uArr►, r�a�o� 18 R�ISIMJVNO AVLj FIBAMI -NJ 07M • 11n tr.�9•w�q,�t,�ufr+wrl,�G�. �� u.a xs ii/�e/tam��w 07/19/2004 17:02 15167478960 MINEOLA NETWORK ENGR PAGE 03 COMMUNIC TIONS SITE LEASE AGREEMENT Th is COMMUNICATION SITE LEASE AGREEMENT("Agreement") is entered Housing into this � day of cnb 2002 (")Effective Date"), by Affordable Associates, Inc., a New York corporation, d/b/a Beacon Wireless Management (July constituted Fire District ("BEACON" or "Tenant") and he Orient k�ireX3D'��1 iR'the Town of Southold,County under the Laws of the State of New York and g of Suffolk,State of New York (" wner" or"Landlord"). For One Dollar($1.00)Pail A to owner,and other h' good a and valuable con agree as the receipt and sufficiency of wch is hereby acknowledged, parties follows; 1. FXCmise�, owner owns real property ("Property").located in the Town of Southold, County of Suffolk,State of New ork,commonly known 233d0 Mai described on Exhibit(Route '25). (SCTM#: 1000-018-5.13.8) The roperty ism particularly annexed hereto. Subject to the provisions onh 2 below (Effective andBeaconleasesfzo)mtOwnner ue Diligence Period),Owner Landl rd hereb y leases to8eac approximately Four-Thousand( ,ODO) s9uare feet of the Prope yy enlexall a s and utility described in easements necessary or desirabletherefor("Premises"),as may be g y the survey anx►exed hereto as Exhibit 2 E c 'v to a 17' ' e e 'o . This Agreement shall be effective on the date of full execution hereof (,,Effective Dant'l7ate as defined in Paragraph 3 belowing on, the Effec ve t{"Due continuand ing until the Term Co enceme Diligence Period"), Beacon sh ll be Pen andboun mitted to enter rsurveysthe �pnspectionserty for handother purposes of making appropriate engineering Y structural and reasonably necessary investigate ns and s�$x'a andhTests""} that 13eac�on may deem environmental tests. (collective y, "'Investigations necessary or desirable to deter ine the physical durconing the DueDiligence Period,that he ty of the Premises, in the event tliat Bea on determ g right to Premises are not appropriate f rtBeacon's in�t�n1ded a not ce o Owner t any t Beacon shall have ime prior terminate this Agreement with u penalty p to the Term CommsnCement-D ite. owner and i Beacon Diligence l Period shall be solely for ge and agree that Beacon's access to the Property the limited purpose of perform ng the Investigations anthe PropeTests,anrty, d shall havethat Beacon shall nno ot be considered an owner or op rator of .any portion of ownership or control of any p ortion of the Land (except as expressly provided in this Paragraph 2), prior to the Terrr Commencement Date.. Beacon agrees that should during the due diligence period the yroperty or premises be disturbed, that it will at its own _I 07/19/2004 17:02 25167478960 MINEOLA NETWORK ENGR PAGE 04 expense reasonably restore same ro the condition in existence on the effective date of this agreement 3, 1=. The term of Beacons tenancy hereunder shall commence upon commercial operation of the Tenant Faciliti sate whichever first oct defined uxs ("Term Commencement months following the Effective , Date")and shall terminate on the fifth anniversary of the Term ComMencernent Date(the "Term")unless otherwise termin ted as provided herein. Tenant shall have the right to extend the Term for five(5)succe 5sive five(5)year periods(the"Renewal Terms")on the same terms and conditions as se forth herein. This Agreement shall automatically be extended for each successive V enewal Term unless Tenant notifies Landlord of its intention not to renew prior to c mmencement of the succeeding Renewal Term, 4, Rent, In consideration for the leasing of the subject Property described herein, Tenant shall pay to Landlord, as full compensation following the Term Commencement Date and monthly for the full tei m that this lease is in effect, fifty percent(50%) of gross rents received by Tenant from I hird•party customers ("Rent'). If, and only so long as Tenant retains four (4) ox mox e third-party customers, then tenant shall pay to the Landlord,as full compensation sixty percent(60%) of gross rents received by the Tenant third-party customers("Re t"),Rent shall be on the first day of each month#ollowine f the Term Cemmenc+ament Da ti . gqNen years after the Term CommMeement Date '�W LaridTvxd's.share,of re�hta�° ?�'" �'� # ty`L a&cQ t(60%)of the.-grGas.renks regardless of the number of-third�P'Afty•* t����: If and when Landlord takes title to the Tenant Facility under an option contai ed herein, then Tenant shall pay to the landlord, as full . compensation sixty percent(60%)of the gross rents regardless of the number of third-party customers. For the purposes of t i6 paragraph"Gross rents"is defined as monies received from Customers for the right t use any and all portions of improvernents (exclusive of additional charges which Custo mers may incur including, but not limited to, insurance, utility charges,architectural and engineering charges,legal fees,taxes and tax surcharges). Tenant shall provide Landlord with copies of signed contract between Tenant and Customers pertaining to impro emerits, Rent for any fractional month at the beginning or at the end of the Term or Renewal Term shall be prorated. Rent shall be payable to Landlord at: Orient Fire District 23330 Main Road (Route 25). Orient,NY 11957-1102 Attention: All of Tenant's monetary obligations set forth in this Agreement are conditioned upon -2- 07/19/2004 17.02 15167478960 MINEOLA NETWORK ENGR PAGE 05 1 recei t of an accurate an executed W9 Form from Landlord. Tenants p 5, se From and after the TerM Commencement ion with the Date,rovis on of comet nlcatioln' . Premises for any lawful activity in connection P services, including but not limite to equipment shelter,nhanced Specialized MobiJeeRadio mounts,Digital Electronic Messagi tS nicatrvice(p£MS), Interactive Video (ESMR), General Wireless Co unications Service (GWCS)► wave DistTibution.Service (LMDS), Multipoint Distribution Service (IVDS), Loco DS) Pexso al Communication Service(pCS),Wireless Microwave'DistributionService( MS), luiar,Broadband PCS,Narowband PCS, Tenant shall Communication Service(WCS)•C Its as Tenantmay have the ongoing right to perfor such Investigations t with Tenant, a Tenant's expense, necessary or desirable. .Landlor agrees to coop and all in making application for and btaining allTenant'slicenses, ice ,iipended use. of ermits and h Premises.ther necessary approvals that may be equ:red for 6. Facillties, Ut' s (a) Tenant has the right to co istruct, replace, mimita ion an a tennperate and agower or rade on the premises cornrnunications fac lases, including without pole and foundation,utility lines, ransa'nisolanes,air antennas,nditioned equipment a standby power generator and electronic equipment,transnnittin and receiving generator pad and supporting ec uipment anooda ai;work necessaryctures therefor ,to prepare,maintain In connection therewith,Tenant 11 s the right t 's b and alter the premises for Tenan business dpecei ers, All of Tenant's c nstruction andconnecting the antennas to the tra matters an ood and installation work shall be perfor ed at Tenant's s of the site plae cost and n and specificati in a ons to he workmanlike manner. Beacons 1ense 1 submitp Landlord for prior appr Val, hich approval will'not be unreasonably withheld or . onditioned. Landlo 1 eiv such approval da s of Landlord's rovide aeceiptcon aof Beacon's planuests s -" th its changes within en(1 ) busines y If Landlord does not provides such es within such word shall broval or e deemed to huest-for ave approved the plans. j�✓, fifteen(15) business day period, andfox Landlord shall not be entitled t receive snit sl�alltholdl consideration,in excangtitle to the Tenant Facil t ese and giving its approval of Beacon s plans. Tenant all of the Tenant Eacilities skull amain Tenant's personal rant astl eperty rightand its sole expense, except as otherwise stated in th s agre subject to Landlord's option top rchase,to remove the Tenant Agreement, and Tenant Facilities at its sole shall on or before the expiration or earlier termination of this repair any damage to the pram ses caused by suet, remove on or the Tenant Facilities fon the, rom the earlier termination of this Agree ent, proporty,but is not required to re move any foundation more than one(1)footbelow grade -3- 07/19/200.4 17:02 1516747B960 MINEOLA NETWORK ENGR PAGE 06 'r level.. ns at the rate c1larged, (b) Tenant shall a for the a ectricity it consumes in its°pnstalle n compliance with' by Sery c ng utility.p mprpV erne is shall be constructed and among others), with all municipal codes (building e p artment, planning and zoning, responsible for obtai ng electrical meters andirectly br from the requice r Utility ,�/C Tenant p , rrtpany,including the instal at on of separate meters fror�n errant shall obtai separate u�ndergrousid utility service and rd agrees to sign Premises. (✓ an utility company that will p ovi may ser required b aid utility companies to provide Y such documents or easements s yuay sucl� service to the Premises, i eluding the grant to Tenant a cross to the Property company at no cost to the Tena t,of an easement in,vservices wired U such servicing tilitY company to Prov Wutility btaining as Tenant's as required Y herein, Landlord agrees to co Aerate fully with the ex pense, anv and all,avorovalsl licenses and uerrnitsrecuire d r Tenanes use of the site. All utility service to the subject property shalla underground. 'is employees,a ents or contractors shall not washout any trucks including Tenant,: but not limited to cement true at or about the subject property. hall have access to the c Tenant,Tenant's a ployees, agents and hours a daycontractors s seven(7)days week, Premises without notice to Ian lard twenty-four(2�) at no charge. Landlord grants Tenant,and trian and vehicents ular ingress and egress across a non-exclusive right and ease ent for pedestrian employees, the Property,as may be gener ly described in Exhibit ur currently x stirs structures (i.e. fire P agents and contractors shall t1 t have access to house and storage facilitv)wit out the Consent of the La�ldlord. All tenant parking shall be restricted to the area so.des gnated.on Exhibit 9 , way d Landlord shall ma retain all access roadways from the aGpCesslat alltimes to the Premises in a manner su flcient to allow pedestrian and er normal weather coedit ons. Landlord shall be responsible for maintaining .and re airiaig such roadwyv,atits ole expense,ebxc�enantvt for an Notwithstanding hst nding the foredo nQ P ge caused by Tenant's use of sucl� roadways which will a repaired Y ("Access Road") subject to Tenant may construct an tc Pro d as may be moresfully described in Exhibit"B", Landlord's approval, across Property if T errant reasonably determin s such Access Road is necessary sary for Tenants ingress to Wing and repairing such egress from the Premises, Te nt shall be responsible fors oad until the expira ion or earlier termination f tear or loss caused by thiti Agreement, other cause beyond at its sole Acres R expense, less reasonable Landlord ldlordr hallll be responsible for any damages to the Access Road • Tenant's control. Lan q7�19/2004 17:02 15167478960 MINEOLA NETWORK ENGR PAGE 07 caused by Landlord's, of Landlord's agents', employees', licensees', invitees' or coritraators', use of the Access Road, and shall be responsible maintaining nation of this repairing the Access Road fro and after the expiration or ea Agreement,which costs shall be Landlord's sole responsibility. 7. 1131 fPr nce. (a) Tenant shall oper to the Tenant Facilities in compliance with all Federal Communications Commission("FCC")requirements and in a manner that will not cause interference.to Landlord,Orient Fire District,or other lessees or licensees of the Property, provided that any such installations predate that of the Tenant Facilities or such installations that are.Bart of the communication system used by Southold Town Police, . Suffolk County Police and the S iffolk County Fire,and Rescue and Emergency Services. Tenant, Landlord and its licenses will cooperate in resolvine interference arisine from future installations of comrnu 'cation systems used by Southold Town Police, Suffolk County Police and.the Suffolk Qunty Fire,-mid Rescue and Emergency Services. (b) Subsequent to the installation of the Tenant Facilities, Landlord will not, and will not permit its lessees or lice sees to,install new equipment on or make any alterations to the Property or property contiguous thereto owned or controlled by Landlord, if such modifications are likely to cause interference with Tenant's operations, In the event interference occurs, Landlord .O1�La dlord s failure to cforts to omply withnate such inte his paragraphf shall be a ere a reasonable time period. material breach of this Agreern nt. 8, Ta s The,Orient Fire District is a real property exempt entity, if pers6nal property taxes are assessed,Tenant shal pay any portion of such taxes directly attributable to the .,� Tenant Facilities, including all real property taxes, assessments it: deferred taxes on the premises —4 IV, btXes due iln . Real estate taxes resulting from the construction of the Tenant Fa Ilities will be borne by, billable to and payable by the Tenant. g, Waiver of LarldLold' (a) .Landlord waives a iy lien rights it may have concerning the Tenant Facilities which are deemed Tenant's personal property and not fixtures, and Tenant has the right to remove the same at any tim a.without Landlord's consent, (b) Landlord acknowledges that Tenant has entered into a financing arrangement -5- 07/19/2004 17:02 15167478960 MINEOLA NETWORK ENGR PAGE 09 including promissory notes an financial and security agreements for the financing of the Tenant Facilities (the "Collate ar)which a third party financing entity (and may in the future enter into additional financing arrangements with other financing entities). In connection therewith, Landlord (1) consents to the installation of the Collateral; (ii) disclaims any interest in the ollateral, as fixtures or otherwise; and (iii) agrees that the for y R shaft be exempt fromdue and that such Collateral may be removedution,foreclosure,sale,levY, / or distress at any time for any Rent due or to become without recourse to legal proceedings. 10• TAIMination, This Agreement may be terminated without further liability on thirty (30)days prior written notice is follows: (i)by either party upon a default of any covenant or term hereof by the other jarty, which default is not cured within sixty (60) days of receipt of written notice of def ult,except that the Agreement shall not be terminated if the default cannot reasonably be ured within such sixty (60) day period and the defaulting party has commenced to cure the default within such sixty (60)day period and diligently pursues the cure to completi n;provided that the grace period for any monetary default is ten (10) days from receipt f written notice; or (ii) by Tenant for any reason or for no reason during the Due Diligei ice Period,provided Tenant delivers written notice of early termination to Landlord pri to the Term Commencement Date;or(iii)by Tenant if it o.r its subtenant does not obtain or maintain any license,permit or other approval necessary for the construction and ope ation of the Tenant Facilities; or (iv)by Tenant if Tenant in unable to occupy and utilize the premises due to an action of the FCC,including without limitation., a take back of cl kannels or chanee in frequencies; or M by Tenant if any governmental environmenta report or such other report acceptable to the Landlord of the Property reveals the vresetice of hazardous material, provided Landlord does not Immediately remedy same; ( I)by Tenant if Tenant determines that the Premises are not appropriate for its operation for economic or technological reasoms, including, without limitation, signal interferenc ;or(vii)by Tenant if the Landlord fails to deliver to Tenant an executed memorandum agreement or non-disturbance and attornment agreement pursuant to Paragraphs'19(g and(h) below. 11 t Co a moation. If the Premises or Tenant Facilities are damaged, destroyed, condemned or ansferred in lieu of condemnation, Tenant may elect to terminate this Agreement a of the date of the damage, destruction condemnation or transfer in lieu of condernnat on by giving notice to Landlord no more than forty-five(45) days following the date of si ch n lieu of damage,terminate this Agreement,Rent shall beemnation or transfer treduced condemnation. If Tenant ch oses not to or abated in proportion to the actual reduction or abatement of rent paid by subtenant on .. t Premises, f L j �,/• 12 e. On the effe tive date of this agreement,Tenant,at Tenant's rule cyst and -6- 07119/2004 17:02 1516747B960 MINEOLA NETWORK ENGR PAGE 09 expense,shall procure and mainta n on the Premises and on the Tenant Facilities, bodily 1? injuryindpro.pertydarnageinsura ice i occurrence. Suchginsuran�eshall snsureMoln�an and 00/100 Dollars ($2,000,000,00 p , occurrence basis,against all Iiabili of Tenant, its employees and agents arising out of or in connection with Tenants use o the Premises, all as provided for herein, Landlord, at Landlord's sole cost and expense shall procure and maintain on the land and its real property located thereon,bodily i ined jury and OQ 17ollars($2 0roperty 0 000 00)per occurrence.ence.e insunInce with a bSuch ' single limit of at least Two Million nd 0 / ' insurance shall insure, on an oc urrence basis, against all liability of Landlord, its employees and agents arising out f or in connection with La ttidlord's use,occupancy and maintenance of th land and Lanc lord's property Iocated thereon, Each panty shall be named as an additional insured on the other's policy. Each party shall provide to the other a certificate of insurance evidencin the coverage required by this paragraph within thirty (30) days following the Effective E ate. 13, ve o Landlord and Tenant release each other and their respective principals,employees,I presentatives and agents,from any claims for damage to any person or to the Property the Premises or to the Tenant Facilities or any other property thereon caused by,or tha result from,risks insured against under any insurance policies carried by the parties and 'n force at the time of any such damage. Landlord and Tenant shall cause each insurance policy obtained by them to provide that the insurance company waives all right of recovery by way of subrogation against the other in connection with any damage cow red by any policy. Neither Landlord not Tenant shall be liable to the other for any darr age caused by fire or any of the risks insured against under any insurance policy required by Paragraph 12, �4. Liability and ndemr►ity Landlord and Tenant shall each indemnify, defend and hold the other harmless from and gainst all claims losses,liabilities,damages,costs,and expenses (including,reasonable ttorney9' and consultants' fees, costs and expenses) (collectively , Losses ) arising from the indemnifying party's breach of any term or conditioxl of this Agreement or from the negligence or willful misconduct of the indemnifying party's agents, employees or contractors in or about the Property. The duties described in this Paragraph 14 shall apply as of the Effective Date of this Agreement and survive the termination of thi s Agreement, 15, Asaianment andSu ettinsr Tenant may assign this Agreement,or sublet or lieZECD the Premises or any portion there f,onlywith the consent of the Landlord which hall be evidenced by written notice thereof to Landlord d-7 within a reasonable period of tim thereafter. Upon assignment,Tenant shalt be relieved bW. of all future performance,liabiliti ,and obligations under this Agreement, provided that the assignee assumes all of Ten nt's obligations herein. Landlord may assign this Agreement, which assignment may be evidenced by written notice to Tenant within a -7- 1 07/29/2004 17:02 15167479960 MINEOLA NETWORK ENGR PAGE 10 reason pe riod eriod of time thereaft r,provided that the assignee assumes all of Landlord's n paragraph 9 Waiver obligations herein, including but riot limitedAgreement Shall Tuntwith he Property and hall be of Landlord's Lien") Above. This Agxeeme their respective successors, personal banding upon and inure to the be efit of the parties, to the contrary j representatives, heirs and assignil Notwithstanding ' th'pt eCdt orotherwise transfer a P in this Agreement,Tenant may asgn,mortgage pledge, Yp entity, or agent without notice or consent its iznteest in this Aghternhas oblient to gations for financing money on behalf of any.financing entity whomTena () 8or in respect of guaranties theref, (ii} hasobligations nder or with respect to enced by bonds, debentures, le letters of notes or similar instruments, or ru) hasobligations credit,bankers acceptances and similar facilities or in respect of guaranties thereof. seized Tit d 'e t Landlord.warrants that Landlord: (i) is 16, wan seized of good and sufficient tit a and intexest to the and has taken alltnecessary act on under its enter into and execute this 11 authority to agxe ment, (ail) rove this agreement , and has laws, by-laws or other relevant docurnentataondloda urther represents that there are no authorized the signatories to exe ute same, L n and that liens,judgments or other impedi eats thatff o olatioz s,thatt would prevle to the ent Property, impede there are no covenants,easement ,restrictions Tenant's intended use of the pro ery.• Landlord le dm rk d s�x�represents a a has never beenrused or designated a landmark or Iota d :n permitted to be used for the gene ration,storage velt�he�l-lazardousr of any 1Materials"),and has or hazardous or toxic substances,materials or wastes(collectively, never been on any list of any goo rnnent rit requiring dl clean-up because or closure of contamination by any daxa dous Materials. Le dovenans andagreswith the Tenant that Tenant May peacefu liy r n quietlyenjoy of all cure Premises, provided o ided that Tenant is not in default hereunder after noexpiration Ali( 17, 1 min. Tenant shall rep it any damage to the Premises or Property caused b .r.Jc.. . Tenant. Except as set forth in Paragraph b(a) above, k�It' upon expiration or terminationff ereof,Tenant shall restore the Premises to substantially w the condition in which it existe upon start of construction, reasonable wear and tear and loss by casualty or other causes beyond Tenants control excepted. 18, pnvi� (a) Landlord and Tena t agree that each will be responsible for compliance with any and all environmental as d industrial hygiene laws, including any regulations, guidelines,standards,or polici s of any g°nducat with regardental to any einviies gronme or ntalr or standards of liability or staan ards of conduct g industrial hygiene conditions o matters a s a t yno or a of d in, or time on the eProperty. r be fect, that are now or Were related to that pax y y � s- 07/29/2004 17:02 15167479960 MINEOLA NETWORK ENGR PAGE 11 o (b) Landlord and Tena t agree to hold harmless and indemnify the other from, and to assume all duties, respo sibilities and liabilities at its sole cost and expense, (for payment of penalties,sanctions,forfeitures,losses,costs,or damages)and,for responding to any action,notice,claim,order,summons,citation,directive,litigation,investigation or proceeding which is related to ( )failure to comply with any environmental or industrial hygiene law, including without limitation any regulations, guidelines, standards or , policies of any governmental at thorities regulating or imposing standards of liability or standards of conduct with regai d to any environmental or industrial hygiene conditions or matters as may now or here (ter be in effect, or (ii) any environmental or industrial hygiene conditions that arise out of or are in any way related to the condition of the Property or activities conducted by the party thereon,unless the environmental conditions are caused by the other party. (C)The indemnifications of this Paragraph 10 Specifically include reasonable costs, expenses and fees incurred in connection with any investigation of property conditions or any clean-up, remediation, removal or restoration work required by any governmental authority. The provisions of this Paragraph 10 will survive the expiration or termination of this Agreement, 19. 012tian After Tenant-has xecove ed all costs associated with the construction of Tenant C. Facility or seven years after the Team Commencement Date, it shall offer to sell to the :Landlord£orTen Dollars($10.0 )said facilities, ate% , - _1 ! 1- 41---_ E ) The purchase of the Tenant Facility by Landlord shall not affect Tenant's rights 15 receive rents as agreed to herein. 20, ce a (a) This Agreement colJ itutes the entire agreement and understanding between the parties, and supersedes alffers, negotiations and other agreements concerning the subject matter contained here Any amendments to this Agreement must be in writing and executed by both parties. (b) Both parties represer t and warrant that their use of the Property and their real and personal property located thereon is in compliance with all applicable, valid and ei-dorceable statues, laws, ord nances, and regulations of any curnpetent government authority. (c) if any provision oft is Agreement is invalid or unenforceable with respect to -9- 07/19/2004 17:02 15167478960 MINEOLA NETWORK ENGR PAGE 12 any patty,the remainder of this A reement or the application of such provision to persons other than those As to whorxa it is Zeld all bed or valid andoenforceablell not be to the fullested and extent each provision of this Agreeme t shall permitted by law. (d)This Agreement shall a binding on and inure to the benefit of the successors and permitted assignees of the re 5pective parties. (e)Any notice or demand equeegr°eliable overnight courier be given herein shall be made to the address iothe or zegistexecl mail,return receipt re uestd respective parties set forth below Landlord: Tenant: O e Beacon Wireless Management 3 0 t 27 Oak Lane „t.N 11957-1102 Hampton Bays, NY 11946 Ath1: Phone: (631)484-5445 . Phone: With Copy'to; With a Copy to: Edward Boyd;Esq. Reilly&Reilly,i,1.P p,O. Box 1468 146 Old Country Road,Ste. 106 Southold, NY 11971 Mineola,New York 11501 Landlord or Tenant may from ti rne to time designate any hall addressher deemed r rec this eived upon by written notice to the other paurpose ty.All notices hereunder s actual receipt. (f)This Agreement shall be governed by the laws of the State of New York. (g)Landlord agrees to exi cute and deliver to Tenant a Memorandum of Agreement in the form annexed hereto as IF chibit C and acknowledges that such Memorandum of ,Agreement will be recorded by Tenant in the official records of the county where the Property is located, (h) In the event that Property is encumberedan executed non-disturbance and Landlord agrees to obtain art deliver to Tenant such mortgage or deed of trust in a form reasonably attornment instrument fox each acceptable to both parties. -10- 137/19/2004 17:02 15167478960 MINEOLA NETWORK ENGR PAGE 13 (i) Landlord agrees to fully cooperate, incluiding executing necessary documentation, with Tenant to brain information and documentation clearing any outstand ing title issues that could a Aversely affect Tenant's interest in the Premises created by this Agreement, (j) In any case where the approval or consent of one party hereto is required , requested or otherwlse.be give un er this Agreement, such party shall not unreasonably delay,condition or withhold its a pxoval or consent. (k)Each of the parties heret represent and warrant that they have the right,power, legal capacity and authority to en er into and perform their respective obligations under this Agreement. (1)The captions and headin s in this Agreement are for convenience only and in no way define, limit or describe the s ape or intent of any provision of this Agreement. (m) All Riders and Exhibits annexed hereto form material parts of this Agreement, (n)This Agreement may be executed in duplicate counterparts,each of which shall be deemed an original. IN WITNESS WHEREOF,I he Parties hereto have set their hands and affixed their respective seals the day-and year first above written. Landlord: Tenant: Bpard oLCommissioners IN I Beacon Wireless Management The Orient Fire District Martin Trent, Chairman Vincent Cannuscio, President Affordable Housing Associates, Inc, d/b/a Beacon Wireless ,¢ a '•�Q Management Ro ert Hicks,Commissio ex c.� L10d-i alin,Commissioner -I1• . ` 0IL1912004 17:02 15167478960 MINEOLA NETWORK ENGR PAGE 14 Gary Tab r, oxnmissio er Joseph ysocki, Co sinner i STATE OF NEW YORK } COUNTY OF SUFFOLK ) On the day of in the year 2002,before me personally appeared MARTIN TRBNT, ersonally known to me or proved to me on the basis of satisfactory evidence to be tf a individual(s) whose name(s) is-(are) subscribed to the within instrument and ackno ledged to me that he/she/they executed the same in their capacity(ies), and that by his/ ier/their signature(s) on the instrument, the individual(s), or the person upon behalf of N rhich the individual(s)acted,executed the instrument. Notary Public STATE OF NEW YORK ) � • ) sc I COUNTY OF SUFFOLK ) On the � day cf (3cfowz , in the year 2002, before me personally appeared ROBERT HICKS, ersonally known to me or proved to me on the basis of satisfactory evidence to bete individuals) whose name(s) is (are) subscribed to the ' within'iinstrument and ackno vledged to me that he/she/they executed the same in their capacity(ies), and that by hisj her/their signature(s)on the instrument,the individuaI(s), or the person upon behalf of Arhich the individual(s) acted0ecuted the instrument. Gam'' Notary Public ItDWARD jur' Natuy 1`011c Ste- r.rrlc 02600:;91s.ia... . Commission Explies Apill 30, 2003 •12. 07/29/2004 17:02 15167478960 MINEOLA NETWORK ENGR PAGE 15 STATE OF NEW YORK ) ) ss: COUNTY OF SUFFOLK ) On the 1�J� day of C 01'$Qt. , in the year 2002, before me personally appeared LLOYD KAL1N, persc nally known to me or proved to me on the basis of satisfactory evidence to be the ij tdividual(s) whose name(s) is (are) subscribed to the within instrument and acknowle ged tome that he/she/they executed the same in their capacity(ies), and that by his/her, their signature(s) on the I strument, the individual(s), or the person upon behalf of whi h the individual(s)ayt�' ,executed the instrument, f,a Notary Public STATE OF NEW YORK ) IEDWARD JOHN BOYD Sth ss: No►ary Public State of New Yolk COUNTY OF SUFFOLK 02Bo03'ys 1s 'i�.i P: L ) Comraisstaa C.,plrus Ana 30. 2 l 30003 On the �'�i day of ctwZrr¢. , in the year 2002, before me personally appeared GARY TABOR, perso ally known to me or proved to me on the basis of satisfactory evidence to be the ' dividual(s) whose name(s) is (are) subscribed to the within instrument and acknowle ged tome that he/she/they executed the same in their capacity(ies), and that by his/he their signature(s) on the instrument, the individual(s), or the person upon behalf of whi h the individual(s)acted, executed the instrument, Notary Public EDWARD JOHN BOYD Sth STATE OF NEW YORK ) Nola►y Public $rate of New York ss: oommeiss�on Expires 376625 (fol April 30,nty 2D03 COUNTY OF SUFFOLK ) On the day of in the year 2002,before me personally appeared JOSEPH WYSOCKI, personally known to me or proved to me on the basis of satisfactory evidence to be the ndividual(s) whose name(s) is (are) subscribed to the within instrument and acknowle Iged to note that he/she/they executed the sazx'I,e in their capacity(ies), and that by his/hej /their signature(s) on the instrument, the individual(s), or the person upon behalf of wh•ch the individual(s) scte!d�.executed the instrument. /r Notarryy Public EDWARD JOHN BOYD 5th Notary Public Stara of Now York -13- 0290"Wr"V, ,;;;F;Ik county comminion Ezplru April 110, 2003 07/29/2004 17:02 15167478960 . MINEOLA NETWORK ENGR PAGE 16 STATE OF NEW YORK ) ss: COUNTY OF SUFFOLK ) On the day of d c:fv&Q'L , in the year 2002,before me personally appeared VINCENT CANNt ISCIO,personally known to me or proved to me on the basis of satisfactory evidence to bt the individual(s) whose names) is (are) subscribed to the withinInstrument and ackno vvledged to me that he/she/they executed the same in their capacity(ies), and that by his her/their signature(s) on the instrument,the individual(s), or the person upon behalf of which the individual(s) acte Y,executed the instrument, Notary Public EDWARD JOHN BOYD Sth Notary Public Steto of Now York 0290010SU5 Sullolk Counly Commission Expires April 30, 2003 07/19/2004 17:0.2 25167478960 MINEOLA NETWORK ENGR PAGE 17 Y846/2900 22;16 413156-14703 M W D 8 PAGE 02 i AWN AM (STATE ROAD 28) r ' q Mew AVEMENT PAR ING AREA(5 ww, 1 i w ! LAW ��1IMM� w riow roc.owora: w rrwr corm mm o � a � KY�LAN V a1w:6M!CstAiLV1eA1.K�R pEOlQiil@1�1�PJl,LLO WSW llrta�sm HORstu1e�1W• 6 TE NO: LI-13-647-6 � 1r1.Vb ile 60VTHCARIMAQtl�H1111A Qz140 ��."'� 0eV6.71 a 7114 px;3COMW7114 a LENT FIRE DEPARTMENT ar vAN wAY.2No Fi.R od /1s7-qt� CATO: PARGIPPANYi NJ070" .T,S. 10/11/02 TO(07313974M NY - Orient Final 10/25/04 Exhibit"B" 16 i 1 { ---MAW ROAD (S.R. 25)-•�•- I ----—-- N80'31' 30-E •_ 226 OW PROPERTY LDLE- TYP_ Ad f : n i ST FIRE STATION NEW UNDERGROUND ELEC7RIC e� AND TELEPHONE SERVICE r:. Im ADEQUATELY SIZED FOR ALL "t •p OW. METAL BUILDING 1 CARRIERS WI7HM BCOMPOUND :OTHERS 47' EXIST. UTILITY POLE (UL�2} 1 Q - 1 a O IaOSL PAVpdELtT i IX &PARIONG AREA I , — T R ro COMPOUND PLAN ON { EXIST. CONCRETE P i ' DWG LE-2 FM DETAILS I � . -�.. W0.7G PROPERTY WORMATION: SITE ADDRESS: =300"IQ ROAD ORIENT. NY 11957 $ECTION: 16 BLOCK 5 N LOT: 118 LANDLORD'S DATE III MUNICIPALITY: TOWN OF SOUTHOLD. NY. SCALE 1-= 100 INMALS i�A�i.�i�/r rt4 wYt - 111 �is��rYsrt�bdlAtilf■pr 10/09/W _ tS STRUCTURAL SITE:ORRWlild ° '• .s S SE1tVICE5,P.C. a0.,� '":,Road ' ""'�°�""°'°'° ' "°` nausrr 2 RtvMMM wL 12110101 t1/41" (1 OF 3) 67FEMM"kOAASl=At.>tRO07 WalLT116:t74 t ==fm RD" tglbt/os � IM-2W&Md FAX-219J7SWO is ssvc a Rwmwi a� I r ! NOM 1.) LOCATIONS OF ALL PROPOSED FEATURES ARE APPROXIMATE j ADDIN ADDITION TO THERLONa ANTENNAS�2)MICROW�DSHALL BE ADDED AT� LOCATIONSTURE ON THis El0iW NINE (9) . OF THESE ADDITIONAL REVS IF ADDED 70 THE MONOPOLE SHALL BE RE5, CIED To THE INSIDE OF THE BY LES#E_ANY 3) PME CABLE TRAYS, CONDUITS AND OTHER CONNECAONS NOT SHOWN ON THIS E70iIBIi SHALL BE PLACED AT A LOCATION TO BE DEfIERMINED*BY LESSEE AND WILL BE Smom ON THE CONSTRUCTIDN DRAWNGS 4.) EXACT LOCATION, LAYOUT AND DETAILS OF ALL PROPOSED FEATURES T'O BE DETERMINED DURING DURING FINAL DESIGN AND WU BE SHOWN QN THE CONSTRUCTION DRAWINGS.ANY EQUIPMENT OR OTHER UTILITY _ i QUIRED By VEMON OF NEW PROVIDER 70 SERVICE LESSEE'S INSTALLATION SHALL BEE PEERMITTED ATT THEE PROPER YORIC. INC. OR ANY OTTTER U71L11Y i NEW GRAVEL COVER WITHIN COMPOUND BY OTHER NEW UNDERGROUND ELECTRIC AND TELEPHONE TRANSFORMER AND VAULT BY OTHERS - SERVICE ADEQUATELY SRED FOR ALL �cRIERS WRHIN COMPOUND BY OTHERS NEW ELECTRIC METER BANK DENTED TO'NEW BY OTHERS WITH NEW PROPOSED 200A SERVICE METER FOR LESSEE'S NEW TELCO HUB CSC CABINET FOR =o" _'e• f- .•`'a. - CONCRETE EpUiP11ENT PAD BY OTHERS COMPOUND BY OTHERS NEW GENERATOR BY OTHER :•� ice:"S� t , - r�:�� ..1 NEW 127 WIDE ACCESS GATE BY OTHERS - _ —NEW EQUIPMENT SHELTER BY OTHERS I NEW 12W MONOPOLE BY OTHERS PROPOSED LESSEE ELECTRIC N> TELCO CONDUITS ROUTED UNDERGROUND FROM CSC CABINET AND I PROPOSED LESSEE ABOVE GROUND CABLE - ,� p Y ' METER BANK TU LESSEE'S EQUIPMENT SHELTIR BRIDGE i :'�' ! NEW CNNN LINK fENCE BY OTHERS, TYP. i �`'•t - j ja: •�•`�r_ SHELTER,PROPOSED] GPS Nryp 2 ABOVE ;r ( ) LIMITS OF LESSOR'S 63'x63' LEASE AREA I 1 I ' PROPOSED LESSEE 12k3O'PREFABRICATED I _, ro EQUIPME SHELTER IN/INTERNAL EMERGENCY NEW CONCRETE DOOR PAD BY OTHERS. ' EQUIPMENT SHELTER DIESEL GENNERATOR NEW EQUIPMENT SHELTER BY OTHERS �, ��;y,_-�;_1-. , , _ -------PROPOSED LIMITS OF LESSEE'S 16'x32' (512 SF) AREA LIWTS LEASE AREA LEASE OF OTHERS, TYP. PROPOSED LESSEE WALL MOUNTED AC 7' UNIT. TYP. FOR (2)TOTAL . 2' PROPOSED CONCRETE PAD CENTERED IN FRONT OF EQUIPMENT SHELTER DOORS Z COMPOUND PLAN I SCALE: 1'- 2O' i �r Ada ir:i.yt. t 5 STItU(.'TUIrAL LE,;s� �'' "no �,�*;r' C CONSULTING SITE:ORIENT °"*• .•F S SERVICES,P.C. ��ie ' I'��, �• L LE-2 e7,+vnny.�r htfAtia.50R7BAw,xtOOTLR1LIin.LT6�SN z �Na n wm „/vm Cl OF 3) Asp= TTtL:2IN.T1&= FATL:2i 7&%7I fm ram. Iw o fI w e TOE TOP OF momopoLE ELEV ,2,.af Acs OTHERS DISTRICT DIPOLE ARRAY BY CENIERUNE OF CONCEALIAEN7 CYLINDER/Oli — — _ ANEL A Ngg SY O7HER5 YOUNSED ANTENNA ARRAY—ay OTHERS - — — — INTERNALLY WITHIN CAN ELEV. 11&0•f AGL CYLJNDER, TYP. CEAL1NhtT - I ����ENT CYlDiDE13 t LI3SFE ANIENMA ARRAY ELEV.1OB.a3 AGILPROPOSED LESSEE PANEL ANTENNAS I Y WTHIN _ CSIX(6ONCFAtIA FOR IELEy, q • Am LEVELS OF TIE(3) ANTENNAS)TOTAL I CENTERLINE OF CONCEALMENT CYLINDER// ANTEMdA ARRAY BY O1HE�— — — — — — — ELEV. 81.0'::k AGi. LOWBAND' WHIP ANTENNAS FOR CENTERLINE OF CONCEALMENT CYLINGFR_L— SOUTHOLD TOWN POLICE AND FIRE ANTENNA ARRAY BY OTHERS — — — — — _ DISTRICT BY OTHERS l ELEV. 71.0'# AGL I NEW 120' MONOPOLE BY OTHERS i APPROX. LATITUDE: N41'GB•33'(MAD" (12W* TALL MONOPOLE + 1'f HIGH APPROX- LONGITUDE W77 17 55'(NApiH3) FOUNDATION) LANDLORD'S DATE APPROX. GROUND ELEVATION: 5 AMEL WEI)LESSEE(b INITIALS ES ROUTED MONOPOLE �.TTENNAip ELEVATION OF ANTENNAS _SOUTH SITE fEAA ELEVATION NOWE NEW WUMACREEMINa BY MX MENT //EblA mw BY LESSEE GPS ANJE XAS auaTY MOUNTED r ABOVE TOP OF SHfLML PROPOSED WALL MOUNTED AC UNITS TYPICAL FOR TWD(2)TOTAL PO6ED LFssa� 125r30' PREFABRICATED T SHELTER i TOP OF GPS ANTENNAS . ELEV. 13.5"f AGL N WALL MOUNTED MW ABOVE } TOP 9E EQUIPMENT I ELEV. 11.5'* AGL GENERA?OR PIPE OP OF MONOPOI NIDAIIII)N ELEV. 1.D•t AGL CHAIN LINK FENCE BY OniaM TYP. 1 - GRADE ELEV. 0' AGL mWm STRUCa v1UL LESSEE w:�+r��b�a4t���dr t0/ot/04 u+—c�o �+�raddd.yrrzre C CONSUMING sip:MEW �oiw w S SERVICES,Y.C. 3 Imim FOt 1ANDUM t„I„/- F LE_3. 2 �so�„�, t, cEA,-E E]fHIBITAS y I T7+J-21t;.T10R7o eg�LT9f it t fis=mR REVRu t0/0i/0t �aaot0 � r. �oR ROROoit yqE I I I - • ", �FBRENiCE COPY . 'I'hla is not au ol�olaT FCC Ilaeate It is a ieoard of public inibrmation oontaf nediD the FCC's Uamising dete6aee an the date that Wie rue ` SPY was genencbed Jn caeca whew FCC mlea regofio de presentedon,poadng qr display of as FCC IIoasee,this document maymt be used in place of ailascial FCC license Rowgyh�', r Federal Communications Commlefion Wireless Teaeaotamunicadone'Bureau - ;,N�. RADIO STATION AUTHORIZATION F LICENSER' AT&T MOBILITY I1 LL:C S I - Can Blga File Number ATTN FCC GROUP C 4,, ' ' WPWU948 AT&T MOBlL1TY ll` C �", Radio 8erylee 5601 LEGACY DRIVE,MS A 3 { WZ-700 MHz Lower Band(Blocica C PLANO,TX 75024 D) FCC Registration Nnmbdr,(Ft21V)t errant Date EBieotive DgtO Bacpiiration Date `.Print Date 01-24-2003. 03-1 ti 2010 06-13 2019,; Market Number, ;� _ Changd Block 9nb-Mitrls�DesiEnAtor CMA001 f r 0 71 ;; ... ..rC..... ., I13ar1tet fVame New York,�N Y'NJ/Ner+sau-Sui?bllc Ist Build-out lDmte 36nd Bufld-out Date 9rd Build-out Date 4tlt Build-out Data 06"P4019 WalmWConditions- If the faoilitios authorized hoinln are used to provide broadcast operation®,whpihcr exolueivcly'or in eombinatfon with other services,the licensee must sack renewal of the ltcenso efdter;within ei 8 ?Y�Pre Isom the,aommencenumt of the broadcast service or within the term of the liaonse had the broadcast service not bean provided,tvhiohever period is shorter in lcuigth.."Soo 47 CFR§27.13(b). Operation of the taoilitiee authorized herein,are subject to the condition That,hamrftcl mterfererrae may not be caireed to,but must be I cc pted from UHF.TV,transmittera in Canada and Meriic6 as identifed in existing and any future agreements with those countries. Conditions Pursuant to§309(h)of the ddinin ications A&of 1934,ae amended,`47 U.S.C.6309(h�this flcense is.subject to the following conditions."This license"shall not vest in'tlie lioemee,any right to operate the station nor arty right in the use of.the frequencies"designated in the license beyond the term thereof nor in'ariy other manner than authorized licrem.;,Neither the license nor the right'gtanted theroundor shell be assigned or'othcrv&e transferred in violation of rho Cotnmuoiaatione`Act of 1934,as amended. Boa 47 U S C.§310(d).'This license is eubjeot in.tmm8 to"the right of use or control conferred by§706 of the Communications Act of 1934,as amended See`47 U S.C.§606.. This license may not euth'orize operation throughout the entire geograPhle ariea or ap6drum identified on die Wild py decsion. To view,the specific geographic area and spectrum authorized by this license,refer to the Spectrum and Harslet Area infornrati tinder the Market Tab of thelicense record'strife Universal Licensing System(UL3):'To view the license record,go to the UL3 homepage at httpJ/warless.fcc.gov/uls/indox:htni?job=homo'end®elect`Liceinse Search". Follow the instructions on how to search for license iniiarmailon. 'FCC 601-MB Page 1 of 1 April 2009 REGPEB WCB COPY This la not an 6molal FCC lkense.it b a icaord of�ublio�nibrmstian'o6alained in the FCC°®licensing database on the date drat ddsroilnenoe copy wee generated.In alas where FCC niles tegalre 8ie pr�mrtetlon,posdng,or display of an FCC Uom n%' this docurrient may not be used in place of an 6ffla l FCC,license °��` r Federal Colilnunllcations Com>miseion Wiretese Telecommunlcalione Bureau RADIO STATION AUTHORIZATION LICEf4aft: qT&T�"OBILITY SPBCTRUM LLC b' Cau Bien no Number ATTN..FCC(WARz WQJU424 AT&T MOBJLITY SPECTRUM LLC $atilo Service StiOl LEGACY DRIVE,MS'-A 3 WY-700 MHz Lower Hand(Blocks A, PLANO,TX 75024 B�g FCC ReBletratlon Nntutbar(FRN)t OO14989726 a Grant Date Effective Dgte Expb%don Date Print Date 01-064009 03-•16 2010: 4g fl6=23-2019 µ Market Number Chan4el Block . Bub-Market DeaiBaator :CMA001 • •g 0 Market`Npme a Nea Yor ! Y=NJ/Nasseu-Suftblk r 1. tat Build-out-Daft 2nd Build-out Date 3rd'2611d-out Date 4th Build-out Date 06-13-2013 06-13-2019: Walvere/Condtfions: If the facilities eutborized herein aroused to provide broadcast operations,whelW exclusively or in oombbution with other services,the licensee must sock renewal of the license`either within eight years from the commencernent of the bioadcast. service or within the tents of the liccm— had the broadcast service not been provided,whichever period is shorter in length..See 47 CFR§27.13(b). Conditions: Pursuant to§309(h)of the Communications Act of 1934,as amended,47 U.S.C.§309(h),this,lioenses subject to the following conditiot>fl: This licerue shall not vest in'the licensee any right to operate the station nor any right in the use of the ttequeneias designated in'the license beyond the term thereof nor 1n any other manner then authorized heron Neither the license nor the right granted thereunder shall bo assigned or otherwise transferred in violation.6 the C nic ommuations Act of 1934,as amended..See.47 U.S.C.§310(d). This licence is mubject in terms to the right of use oc control conferred by'$706 of the Communications Act of 1934,as amended See 47 U.S.C.§606. r; >a This license may not authori2ie operation throughout the entire geographic area or spectrum identified on the hardcopy version. To view the specific geogfaphic area end spectrum authorized by this license,refer to the Spectrum and Market Nee informati under the Market Tab of the license record in the Universal Licensing System(ULS). To view the license record,go to the ULS homepage at http://wireless.fcc.gcvv/Ws/inda.hti4ob=home and select"License Search". Follow the instructions on how to search for license information. FCC 601-MB Page 1 of 1 April2009 UL'R 10"NSW AiNOULAR WMRM8 ✓ D '' a r 5. , r t i , \ 46 j' 1 t F'1 i Universal Laensine' y®t+�m UL6 LlOO:IfO 4 Cellular Llc®nee -.KIVKA�J10 - NBW CINt�tUTAR W=RBLBBB pm;:LLC can", pm wvq „1 i - Call� :' �1♦l�.910 F; - a �{� A4t1V0 ° A11t11'ryp0 :.�QV� , M■io� Meeker OMA001 flew Yc* Y.` Chettt1e1;8bo QOew� :q Fraauen�e�1 N7/Nae�au-Sullbik Z Sutrrarkat 0 pram, 0s/ld/Z006 Rxpirodwt iq/OUROi6 o�/ie/zoio ae>e�on Ww v1w,Ewnao Oi/17/2000 canbnl Polnls �, a w,Pgssgtc srae�r,i<OCHP1Le PAalc,w Mer:het n Swlmfi�81O R Avetuie,New`Yor1i,NY 000a2at sz 'rYpe um!oed uebinty t:omPOW �yuunp�tla� u�n.•e s , NEW CWGULAR,VYIRI?LS9S Pc9�LLB Pt(!{6p ZZO-7471 86Oi LSGAC*DRNE,1+�:A 9 p:(489 ZZQ-7297 PUWO�`TX 750Z4 6;t Oi�►ATWOM ATTN FCC group OonLe Al&7 M00111TY WC Pt(102 Z05S MlctroetP poppin F; � 3074 1120 ZOtFI 8traet,NW,6ulto 1000 http:l/wire�eea2S�o.»v :, 41iMV-13092 5/7 1dol0 : t 1"Wense peliuler I3aacauaa'-BNLC�1910 NBW,CQ GULAR WIIlB�R88 PCB,LLC ``. Pale aP� WaQhlnpbn,I3C 20098 coom fMg11 Am a91eie1 P,c�oppin .n Ownentiilp and,.pwllAdmttone Mobtle, Radio 8arotce .. r YYpe .etatw . pep � Cortunon Cornier Inwunonneabed Yes A!!.n oWnal* The eoowered'Wbo such of the quosgone. B Ic quomuntiotr The App9cant answered Vo'to each of the QiIWIEIO IOn questlona D�nograipitle® .Race ' etfiNeKY ®end°r. } UL9 Mdp i�19tY ,", �01'�1611i1'ilOiL ,Wi0001048YRR to l4[fnllne Rpino �p,�p<� �pp�{I�I�BOBI�i 1' UO Oniitilli 0100} Above ULS FGCI1�ls `: • Federal Commurdcndone won Phones 3�77-,80 9201 � 4as•ia Stied OW TTYt 1.6717.3W,284 Wdehinpmn,OG Io�4 3�Yet{l.8®Wlmt bttp:/�slcw2 /Uls�pg/[ne8e�+c /l s:oaee,ep?lioK�13092 srr7r2oio RF.FIMIDICB COPY Ttds is not an otHolel FCC linenaa It to a reoera of pnbllo bribimstlon oonteinad in the FCC@ 0oansing database on the'daw that tliia referaooe copy was e}�ed.bi oases wbme FCC ndes tom the py gm teq p wantal postin&'or display of an FCC lioao�e;this dooumegt may not be used in plade of rm ortlalel FCC flceiue. Fed®ral-Commnnlcation& Commi��ion Wirelege TtlecommnnfoRtlong Bureau RADIO STATION AUTHORIZATION LIC13149138: 'NGW CINCIULAR WBUUESS PCS,LLC coo't3len =_ File Number AT FN:FCC.GROUP. '� ` WPOL31l NEW C1KGULkR W.ikkm, PCS,,LLC 5601 LEGACY DRIVE,MS 3 ` Radto'8®rvvlce- CW=PCS Broadband PIANO,TX 75024 . FCC Regletraflon Nnaiber.(FR1V).`'.0003291192 ? Grant Date Rileotive Dgte,r Explrratlon Dnto Prlut Date 17 r 08-15 2007 03=16-201t), l Y, O027 2017 Market NumbeF t` Channel H10 i3trb Hansel Desigitatar'` BTA321 g 2 Marital Name. 31 Build-ont DttLa 26d Bnild4ut Date r 3rd Hand-oat Date 4tL Build-out Date 06,27-260Z Wahrors/Coadidiinet This lioenso is conditioned upon 6nipNenoe with the pnovieioni of Applioatigns aoPAT&T Wire]ees Serviaea,.lnc.and Cing rlar . Wireless Corporation For Consent.to; ransfer Control of Licenses and Authorizations,Memorandum Opinion and Order,FCC 04-255(Tot Oot.2b.2004) Commission spproval of this epplioetion and,the ltaenses contained t}iarein are subject to the"di lions set forth in the ., Memorandum Opinion and Order,adopted onDeeeinber 29,2006 and released.on March 26.20t)7,and revised in Order on lteconsideiatioa,adopted and released on.Maroh 26,2007.See'AT&T lr e.lia BellSouth Corporanon•Aj Pliosll * for TYani%f of,Conirol,WC Docket No:'06-74,Metrtoraeidum Opinion end Order,FCC 06=189(rel Mer,26,20.67) AT&T Inc.and BellSouth Cotporetiona WC Docket I�9o:06-74,Order,an Recotisideratioa,`FCC 07-44(rel Mar`20,1007), Conditions Pursuant to§309(h)of the Cominunications Act of 1934.as amended,47 U.S.C,J309(h),this license is subject W the ti llowing'conditions. This license ohall not vest in the lieensee.any'right to operate the atetlan°nor an right in the use of the frequenciea designated in'tha license beyond the term thereof nor in any other manner than authorized harem ';Noithor the license nor the ri ht " anted thereunder shall bo assi `g grant fined or otherwise transfer ed in violahon of the Commumoahons Act of 1934.as amended.'Sao 47,U S C. 31 d. This license is sub eot in terms to the rl t of use or con by by 1706 of a ) j the Communioatlone Act of1934,as,amended See,47 U.S.C;.$606. ,{ .v This licem ma not authorizo oration throughout the entire eo hic armor ectrum identified on the'hatdcopy..... on. y. op„ 8h 8 8xap eP :w To view the span c.l eographte area and spectrum authonzod by'this licensa,refer to the Spechvm and Market Men inforniati under the Market Tab of the license accord in the Universal,Lieeasin System LS . To view the license record,. g .;Y N ) a,ga to the ULS homepage at http://wireless.fcc.gov/Wdindez.htm7job-home end select"License Search". Follow the'instructions on how to search for license information. FCC 601 MB Page 1 of 1 April 2009 INFERENCE COPY,. This is not as official FCC umnaa.It is a teoord of public 3aftmation contafined is the.FCC's lioeneing detsbose on die"drat this n0,tenoo copy was genonsted In oasm where PCC rules poetiag,'as display of an FCC license,this doosaneat may not be used In plane of an off oral FCC bccru6 a OHM � '` . . `,;. •, FV 'Ae d Communications Comnussion .9 R Wireless Telec'wmunicationtl`Burean . •.• K sue��✓ RADIO STATION AUTHORIZATION LICBN9E$ NEW CINOULAR WHUH BSS PCs,LLC 4 Ca11 Slgn Fb Number , ATTN FCC QAOUPf<. �' WPSL626 NSW CINOULAR WIRBZB99 hGB,LLC Bailie Berviae 5661 LEGACY DRIVE,MS ;lk 3 CW PCS Broadband PLANO,TX 75024 • fir; ' � � FCC Regisoration Number(FRIV)s 0003291192 h.•'.' Grunt Date' B,fdeetiv®jDgtt3 a lE:plratlosi Date Print Data �. 1244-2014 �} 07-15-2005... 05-02 :.. Market Number �a ,` Channel Hdoek Butt-Market Deslgaptar 7 . MarketrName �NoW'lp York , let Build-odf Data 2nd Bngd-0ut Date 3rd BuBd-out Date 4tti Build-ont Date 12-14-1999 12.142004 Walvers/CondwoWs: Spectrum Lease associated with th s licenso. See Spectrum Leasing Arrangement i.ettar dated 12/OT/2004 end File No, 0001757186.._ Spectrum Leasing Arrangement aseoclatod with file nunrboi 0001757186 was extended to 0I105/2009. See file number 0001885143. Condition$: Pursuant to 1309(h)of.the Communicadone Act of 1934,as'amended,47 U.S.C.:§309(h),th4s"licensa is subject to the following conditions: This lice=,shall not vest in the iroensw any right to operate the station nor any' ghtyin the use of the frequencies designated in the license beyond the tenri thereof nor in any other manner than authorized herein.' Neither the license nor'tho right guartted thereunder shall be assigned or otherwise transferred m violagon of the Cornmumoations Act of 1934,as amended.:_Seo 47.U.S.C,,§'310(d). This Nootiee ie subject in,teime to the right of use or control,conferred by¢706 of the Commmnications Act of 1934 as amended.:See 47 U'S,C;.§606. This license may'not authorize ope'ption,dvvughqut the entire geographic area or spectrum identified on,the hardcopy"Version. To view thespecific geographic aroa end spectsvm,.authorized by this license,refer to the Spectsvm and'Mark ot Gina infsnmatio under the Market Tab'of the license record in the Universal Licensing System(ULS). To view the license record,go to the ULS homepage at htip://wimiss.fcc:gov/uls/indeiLhtm?job=homo end aclect"License Search". Follow the inetnictioste on how to search for license information. FCC 60l MB Page 1 of 2 April 2009 , Licensee Name. NEW imOULAR VIRI Lqi B38 PCS,LLC Call Sign WP8L626 , , Rile Numbers Print Datet C�Cmimieeiun,ap royal of tlds�upplioatic�►end tlio liooaeoe aontefnod Mein am eubjeat to the aonditimie eat 1b�in the Mainanndum l lbn and Order,adopted am December 29,2006 aad released oa March;Z6,2007,ead iid d in the thdet on Reoonsideratlon,adopted end released on Mecph 26,2007 Bee AT& bid and Be118auth CarQauatian A Uoedoa`t�Thaeft of Conaol,WC Docket No 06-74,Memnaaandiim Opinion and Order,FCC 06 I t39(Tel 11� 26;2007); TBtT lna and BellSouth Corporation,WC DopketNo,06 74r�der on Reaoaeldetadori,PCC,07114(ral.Mar`2b,2007)" • 1 t. �+3r k; i i 1 e^ 4 r J 2 x ` FCC 601- Pago of 2 Ap ll 2009 f This is not an oil;iDiel FCC lleoneo It is a cord of lie b1�Uon'oantainu is the FCC's pab Nomidng database on the date tLai thie'referenee copy was gmidratad.`!n oaeos,ahare FCC rules require the presentatioq posdag,or display of m FCC license,tlda dooament may not be used In piece of an pfAoial ACC lieen®e Federal.Colmmanlcationa CO!><lfl1 ion Telecomintiinieatwus But RADIO StAlim AThM01RM1fl0N ; LICBNSI3$: -NEW CINGULAR WIRALBSS,PCs,LLC �' ' CaI1 Slgo Bqe Number ATTN:FCC aItOUP '' " WQ00892 NBW CINQULAR WIRE LB99 PCS,LLC : litadlo Service 5601 LEGACY DRIVE,MS°A s3 CW=PC3 Broadband PLANO TX 75024 FCC Regletratlon Number 0kN)t 0003291192 Grant e D'A" Expiration Dale Prbrt Date 1141 4006 03-1 b 2010, s 12-14-2014 x. , Y Ma Ad,,Nmntiber. ;, CWngel Block (9ub-Market Detdgnator MTAOiII ti A 14 Market Name New York let Build-out Date ZndBufld-out Date 3'r"d'Buiid-ottt Date 4th BuW1-out Date Waivers/Conditions'. NONE Conditions: Pursuant to 004)oithe Communications Aaf of 1934,as,amende447 U,S.C.8309(h�this llcense`is subject to the following cdnditioes `This license'shall itot vest in the ltoensee any,right to operate the station nor any right in the use of the frequencies designated in'the license beyond the term thereof nor in,ary other manner than authorized harem ,Neither the license nor the right granted thereunder shell bo assigned or otherwise transferred in violation bVilie Commii6kations Act of 1934,as emended. See 47:U S C.:§310(d)`;Tlue Uoeuse u®ubJeat in terms to the right of use-or control conferred by§706 of N., the Communications Aof of,1934,as amended;Sao 47 U.S.C:§606.;` This license may not authorize operation throughout the entire geographic area or spectrum identifies on the`hardcopy version; To view the Specific geo9raphtc area and spectrum autharized by thin license,refer to the Spectrum and Market Area inforrnatto under the Market Tab of the liceiu'a ord in the.Universal Licensing system(ULS). To view the license record,go to the ULS homepage at http:l/wimleas.fec,gov/ulsI./indox.htm7jol�home aI"Ind select"License Search".. Follow the instructions on how to search for'lieense infbimaddit. FCC 601-MB Page 1 of 1 April 2009 i www.gtpsites.com G'r'P Structural Analysis Report Global rower Padnca 90 ft. Stealth Monopole 23300 Main Road, Orient Point, NY 11957 Suffolk County (NY-5015, Orient Point) Global Tower Services 750 Park of Commerce Boulevard Suite 300 Boca Raton,FL 33487-3612 P: 605.422.1548 F: 605.422.1550 AT&T AT&T Site Name: Orient Point AT&T Site Number: NYCENY0735 Prepared by: Global Tower Services, LLC Michael T. De Boer, P.E. Senior Director of Engineering January 9, 2013 Global Tower Services, LLC- January 10, 2013 Orient Point NY-5015 Table of Contents Introduction...............................................................3 Descriptionof Structure................................................3 DesignParameters.......................................................3 Antenna Loading Information.........................................4 Analysis Results 4 - 5- 5 AnalysisSummary and Conclusions.................................5 StandardConditions......................................................6 Disclaimer of Warranties...............................................7 Appendix A - Monopole Profile.............................Attached Appendix B - Calculations....................................Attached Appendix C - Collocation Application.....................Attached Global Tower Services,LLC January 10,2013 Orient Point NY-5015 INTRODUCTION We have completed the structural analysis for the existing 90 ft. stealth monopole located in Suffolk County(23300 Main Road, Orient Point),NY. The objective of the analysis is to determine if the existing Stealth Monopole design is in conformance/compliance with the current codes and standards for the proposed equipment installation. TSTower written by TowerSoft was utilized in performing the analysis. This program is a commercially available software program which was used to create a non-linear three- dimensional beam model and calculate member stresses for various loading conditions. DESCRIPTION OF STRUCTURE The existing structure is a 90 ft. Stealth Monopole. The original monopole manufacturer is Fred A.Nudd Corporation, Ontario,NY. The existing monopole consists of two (2) sections with a slip connection and 40' of stealth concealment cylinders. Original monopole drawings provided by Nudd Corporation were used to model the monopole steel. (Mudd Job No.: 105-12113-1, May 17,2005)The monopole shaft is manufactured from 65 ksi steel ,the base plate is 50 ksi steel and the anchor bolts are A36 steel. The monopole, for the purpose of analysis, is considered to be in good condition with no defects. DESIGN PARAMETERS - Standard: ANSUTIA-222-G-2005 -Local Building Code: New York State Building Code -Basic Wind Speed: 120 mph(3-sec gust) - Serviceability Wind Speed: 60 mph(3-sec gust) -Basic Wind Speed with Ice: 50 mph(3-sec gust) - Design Ice Thickness: 0.75 (inch) - Structure Class II - Exposure Category C -Topographic Category 1 Global Tower Services,LLC January 10,2013 Orient Point NY-5015 ANTENNA LOADING INFORMATION Existing and Reserved Loading_Information Ariteaa�na Descz tion/Mount . e ft M ,TX Lnes. y Customer. 4 ft. Omni 1 92 7/8" 1 Orient FD Empty Stealth Canister 3 85 TBD 12' x 18' Flag 1 84 - Kathrein Panels/Stealth Canister 3 75 7/8" 12 AT&T To be removed and replaced) Remain Andrew ETB19G8-TMA/ 6 75 AT&T Stealth Canister X7CAP-480i/Stealth Canister 3 67.5 7/8" 6 Verizon X7C-480/Stealth Canister 3 62.5 1 7/8" 6 Verizon Omni Antennas/ Side Arms 4 45.5 `/z" 4 Orient FD Proposed Loading Information 'r.' `_,An ON09,� Q, s ,Elev„ (yft) �TX Ltries �,a, ,ty# Customer: Andrew DBXNH-6565A/ 3 75 Existing 12 AT&T Stealth Canister Kaelus DBC0037F1V2-X Diplexer/ 6 75 AT&T Stealth Canister Note: Final configuration for AT&T: Three (3) antennas,six(6)TMAs,six(6)' diplexers, and twelve (12) 7/8" lines. Lines are shielded inside the shaft and all antennas are concealed inside the stealth cylinders. ANALYSIS RESULTS Structure The existing 90 ft. stealth monopole is structurally capable of supporting the proposed equipment. (See table below) Mcirio'"G,leIvlemb'er �e :%Ca„acif� .;Resu_lts$ Monopole Shaft 99 Pass Monopole Base Plate 53 Pass Anchor Bolts 97 Pass (105 percent is considered acceptable.) Global Tower Services, LLC January 10, 2013 Orient Point NY-5015 ANALYSIS RESULTS continued Foundation The existing foundation has also been evaluated. The existing foundation was found to be acceptable. Existing foundation and geotechnical information was provided by Fred A.Nudd Corporation. Monopole Rating: 99% SUMMARY AND CONCLUSIONS The existing 90 ft. Stealth Monopole located in Suffolk County(23300 Main Road, Orient Point),NY is structurally acceptable based upon the EIA-222-G 2005 Standard and the New York State Building Code with the proposed equipment installed. If any other changes are proposed, another structural analysis should be performed to assure the tower is in compliance/conformance with the applicable codes and standards. Should any further questions arise,please contact the Global Tower Services, LLC Engineering Department at 941-400-2206 Global Tower Services, LLC Reviewed By: E pF NE;y ,01Q��.PEI'T. CO 9 r N0. 0725'so 9�FESSIONQ�' Phillip Nejman, E.I. Michael T. De Bo r, P.E. GTS Engineering Senior Director of Engineering Global Tower Services,LLC January 10, 2013 Orient Point NY-5015 Standard Conditions All engineering services are performed on the basis that the information used is current and correct. This information may consist of,but not necessarily limited,to: - Information supplied by the client regarding the structure itself, the antenna and transmission line loading on the structure and it components, or relevant information. - Information from drawings in possession of Global Tower Services,LLC, or generated by field inspections or measurements of the structure. It is the responsibility of the client to ensure that the information provided to Global Tower Services, LLC and used in the performance of our engineering services is correct and complete. In the absence of information contrary, we consider that all structures were constructed in accordance with the drawings and specifications and are in an un- corroded condition and have not deteriorated; and we,therefore consider that their capacity has not significantly changed from the original design condition. All services will be performed to the codes and standards specified by the client, and we do not imply to meet any other code and standard requirements unless explicitly agreed to in writing. If wind and ice loads or other relevant parameters are to be different from the minimum values recommended by the codes and standards,the client shall specify the exact requirements. In the absence of information to the contrary, all work will be performed in accordance with the revision of ANSI/TIA/EIA-222 requested. All services are performed,results obtained and recommendations made in accordance with the generally accepted engineering principles and practices. Global Tower Services, LLC is not responsible for the conclusions, opinions and recommendations made by others based on the information we supply. Global Tower Services,LLC January 10, 2013 Orient Point NY-5015 Disclaimer of Warranties The engineering services by Global Tower Services,LLC in connection with this Structural Analysis are limited to a computer analysis of the tower structure, size and capacity of its members. Global Tower Services,LLC does not analyze the fabrication, including welding, except as included in this report. The purpose of this report is to assess the feasibility of adding appurtenances usually accompanied by transmission lines. Any mention of structural modifications are reasonable estimates and should not be used a precise construction document. Precise modification drawings are obtainable from Global Tower Services,LLC but are beyond the scope of this report. Global Tower Services,LLC makes no warranties, expressed or implied, in connection with this report and disclaim any liability arising from material, fabrication and erection of this tower. Global Tower Services,LLC will not be responsible whatsoever for or on account of, consequential or incidental damages sustained by any person, firm, or organization as a result of any data or conclusions contained in this report. The maximum liability of Global Tower Services,LLC pursuant to this report will be limited to the total fee received for preparation of this report. APPENDIX A Tower Profile TSTower - v 5.3.2 Tower Analysis Program Licensed to: Global Tower Partners (c) 1997-2012 TowerSoft www.TSTower.com Boca Raton, FL File: C:\Documents and Settings\pnejman\My Documents\Work\NY-5015_011013\NY-5015 SA 011013_ATT.out Contract: Revision: Project: Structural analysis of 90' Flagpole Site: NY-5015 (Orient Point) Date and Time: 1/10/2013 2:30:48 PM Engineer: Mike De Boer DESIGN SPECIFICATION ' Design Standard:ANSI/TIA-222-G-2005 Add.2 i Basic Wind Speed(No Ice)=120.0(mph) Basic Wind Speed(With Ice)=50.0(mph) Design Ice Thickness=0.50(in) Structure Class=II Exposure Category=C Topographic Category=1 Sct. Length Overlap To Dia.Bot Dia.Thick. (ft) (ft) (in� (in) (in) 1 45.00 5.00 36.45 41.36 0.2500 2 10.00 0.00 36.40 37.50 0.2500 3 10.00 0.00 12.75 12.75 0.5000 4 10.00 0.00 12.75 12.75 0.5000 5 10.00 0.00 12.75 12.75 0.5000 6 10.00 0.00 12.75 12.75 0.5000 90.00 -I- MAXIMUM BASE REACTIONS Download(Kips) 16.4 Shear(Kips) 17.2 Moment(Kipsft) 931.6 Appendix 1 APPENDIX B Calculations TSTower - v 5.3.2 Tower Analysis Program Licensed to: Global Tower Partners (c) 1997-2012 TowerSoft www.TSTower.com Boca Raton, FL File: C:\Documents and Settings\pnejman\My Documents\Work\NY-5015_011013\NY-5015 SA 011013_ATT.out Contract: Revision: Project: Structural analysis of 90' Flagpole Site: NY-5015 (Orient Point) Date and Time: 1/10/2013 2:30:48 PM Engineer: Mike De Boer Section A: PROJECT DATA Project Title: Structural analysis of 90' Flagpole Customer Name: AT&T Site: NY-5015 (Orient Point) Contract No.: Revision: Engineer: Mike De Boer Date: Jan 10 2013 Time: 02:06:45 PM Design Standard: ANSI/TIA-222-G-2005 Addendum 2 GENERAL DESIGN CONDITIONS Start wind direction: 0.00 (Deg) End wind direction: 330.00 (Deg) Increment wind direction: 30.00 (Deg) Elevation above ground: 0.00(ft) Gust Response Factor Gh: 1.10 Structure class: II Exposure category: C Topographic category: 1 Material Density: 990.1(lbs/ft^3) Young's Modulus: 29000.0(ksi) Poisson Ratio: 0.30 Weight Multiplier: 1.00 WIND ONLY CONDITIONS: Basic Wind Speed (No Ice) : 120.00(mph) Directionality Factor Kd: 0.95 Importance Factor I: 1.00 Wind Load Factor: 1.60 Dead Load Factor: 1.20 WIND AND ICE CONDITIONS: Basic Wind Speed (With Ice) : 50.00(mph) Directionality Factor Kd: 0.95 Wind Load Importance Factor Iw: 1.00 Ice Thickness Importance Factor Ii: 1.00 Ice Thickness: 0.50(in) Ice Density: 56.19(lbs/ft^3) Wind Load Factor: 1.00 Dead Load Factor: 1.20 Ice Load Factor: 1.00 WIND ONLY SERVICEABILITY CONDITIONS: Serviceability Wind Speed: 60.00(mph) Directionality Factor Kd: 0.85 Importance Factor I: 1.00 Wind Load Factor: 1.00 Dead Load Factor: 1.00 Analysis performed using: TowerSoft Finite Element Analysis Program Page A 1 TSTower - v 5.3.2 Tower Analysis Program Licensed to: Global Tower Partners (c) 1997-2012 TowerSoft www.TSTower.com Boca Raton, FL File: C:\Documents and Settings\pnejman\My Documents\Work\NY-5015_011013\NY-5015 SA 011013_ATT.out Contract: Revision: Project: Structural analysis of 90' Flagpole Site: NY-5015 (Orient Point) Date and Time: 1/10/2013 2:30:48 PM Engineer: Mike De Boer Section B: STRUCTURE GEOMETRY Total Height Bottom Diameter Top Diameter (ft) (in) (in) 90.00 41.38 12.75 Sect. Length Overlap Bot Dia. Top Dia. Thick. Sides Joint Type Yield Mass Calculated No Stress Taper (ft) (ft) (in) (in) (in) (ksi) (lbs) (in/ft) 1 45.00 5.00 41.38 36.45 0.2500 18-sided Flange 65.0 4697.8 0.10950 2 10.00 0.00 37.50 36.40 0.2500 18-sided Telescopic 65.0 990.9 0.10950 3 10.00 0.00 12.75 12.75 0.5000 18-sided Flange 42.0 661.6 0.00000 4 10.00 0.00 12.75 12.75 0.5000 18-sided Flange 42.0 661.6 0.00000 5 10.00 0.00 12.75 12.75 0.5000 18-sided Flange 42.0 661.6 0.00000 6 10.00 0.00 12.75 12.75 0.5000 18-sided Flange 42.0 661.6 0.00000 Total Mass: 8335.1 Page B 1 TSTower - v 5.3.2 Tower Analysis Program Licensed to: Global Tower Partners (c) 1997-2012 TowerSoft www.TSTower.com Boca Raton, FL File: C:\Documents and Settings\pnejman\My Documents\Work\NY-5015_011013\NY-5015 SA 011013_ATT.out Contract: Revision: Project: Structural analysis of 90' Flagpole Site: NY-5015 (Orient Point) Date and Time: 1/10/2013 2:30:48 PM Engineer: Mike De Boer Section D: TRANSMISSION LINE DATA Transmission Lines Position No. Bot E1 Top E1 Desc. Radius Az. Orient. No. Shielded Shielded Antenna (ft) (ft) (ft) Lines 1 5.00 90.00 LDF5P-50A 0.00 0.00 0.00 1 Yes 1 2 5.00 75.00 LDF5P-50A 0.00 0.00 0.00 12 Yes 12 3 5.00 67.50 LDF5P-50A 0.00 0.00 0.00 6 Yes 6 4 5.00 62.50 LDF5P-50A 0.00 0.00 0.00 6 Yes 6 5 5.00 45.50 LDF4P-50A 0.00 0.00 0.00 4 Yes 4 Transmission Lines Details No. Desc. Width Depth Unit Mass (in) (in) (lb/ft) 1 LDF5P-50A 1.10 1.10 0.33 2 LDF5P-50A 1.10 1.10 0.33 3 LDF5P-50A 1.10 1.10 0.33 4 LDF5P-50A 1.10 1.10 0.33 5 LDF4P-50A 0.63 0.63 0.15 Utilization of the cross-section for TX Lines: 22.00% Page D 1 TSTower - v 5.3.2 Tower Analysis Program Licensed to: Global Tower Partners (c) 1997-2012 TowerSoft www.TSTower.com Boca Raton, FL File: C:\Documents and Settings\pnejman\My Documents\Work\NY-5015_011013\NY-5015 SA 011013_ATT.out Contract: Revision: Project: Structural analysis of 90' Flagpole Site: NY-5015 (Orient Point) Date and Time: 1/10/2013 2:30:48 PM Engineer: Mike De Boer Section F: POINT LOAD DATA .Structure Azimuth from North:0.00 POINT LOADS No. Description Elev. Radius Azim. Orient. Vertical Tx Line Comments Offset (ft) (ft) (Deg) (Deg) (ft) 1 4' Omni 92.00 0.00 0.0 0.0 0.00 3709-Fire Dept 2 10' x 33.86" Canister 85.00 0.00 0.0 0.0 0.00 GTP 3 12'x18' Flag 84.00 0.00 0.0 0.0 0.00 GTP 4 (3) DBXNH-6565A 75.00 0.00 0.0 0.0 0.00 9886-ATT 5 (6) TMAs ETB19G8-TMA 75.00 0.00 0.0 0.0 0.00 9886-ATT 6 (6) DBC0037F1V2 75.00 0.00 0.0 0.0 0.00 9886-ATT 7 10' x 34.23" Canister 75.00 0.00 0.0 0.0 0.00 GTP 8 (3) X7CAP-480i 67.50 0.00 0.0 0.0 0.00 9885-VZW 9 10' x 35.31" Canister 65.00 0.00 0.0 0.0 0.00 GTP 10 (3) X7C-480 62.50 0.00 0.0 0.0 0.00 9885-VZW 11 10' x 36.04" Canister 55.00 0.00 0.0 0.0 0.00 GTP 12 (4) Omni Antenna 45.50 0.00 0.0 0.0 0.00 3709-Fire Dept 13 (4) Side Arms 45.50 0.00 0.0 0.0 0.00 3709-Fire Dept POINT LOADS WIND AREAS AND WEIGHTS No. Description Frontal Lateral Frontal Lateral Weight Weight Gh Bare Area Bare Area Iced Area Iced Area Bare Iced (ft^2) (ft^2) (ft^2) (ft-2) (Kips) (Kips) 1 4' Omni 1.50 1.50 2.00 2.00 0.02 0.03 1.10 2 10' x 33.86" Canister 21.11 21.11 21.11 21.11 0.25 0.25 1.10 3 12'x18' Flag 18.36 18.36 18.36 18.36 0.50 0.50 1.10 4 (3) DBXNH-6565A 0.00 0.00 0.00 0.00 0.10 0.10 1.10 5 (6) TMAs ETB19G8-TMA 0.00 0.00 0.00 0.00 0.10 0.10 1.10 6 (6) DBC0037F1V2 0.00 0.00 0.00 0.00 0.04 0.04 1.10 7 10' x 34.23" Canister 21.48 21.48 21.48 21.48 0.25 0.25 1.10 8 (3) X7CAP-480i 0.00 0.00 0.00 0.00 0.09 0.09 1.10 9 10' x 35.31" Canister 22.56 22.56 22.56 22.56 0.25 0.25 1.10 10 (3) X7C-480 0.00 0.00 0.00 0.00 0.09 0.09 1.10 11 10' x 36.04" Canister 23.29 23.29 23.29 23.29 0.25 0.25 1.10 12 (4) Omni Antenna 8.00 8.00 10.00 10.00 0.08 0.12 1.10 13 (4) Side Arms 8.00 8.00 12.00 12.00 0.12 0.16 1.10 Page F 1 TSTower - v 5.3.2 Tower Analysis Program Licensed to: Global Tower Partners (c) 1997-2012 TowerSoft www.TSTower.com Boca Raton, FL File: C:\Documents and Settings\pnejman\My Documents\Work\NY-5015_011013\NY-5015_SA 011013_ATT.out Contract: Revision: Project: Structural analysis of 90' Flagpole Site: NY-5015 (Orient Point) Date and Time: 1/10/2013 2:30:4B PM Engineer: Mike De Boer Section H: STRUCTURE DISPLACEMENT DATA Load Combination Max Envelope Wind Direction Maximum displacements Elev. N-S Disp W-E Disp Vert.Disp N-S Rot W-E Rot Twist Rot (ft) (in) (in) (in) (deg) (deg) (deg) 90.00 34.4 34.4 -0.7 3.79 -3.80 0.00 88.33 33.1 33.1 -0.7 3.79 -3.80 0.00 86.67 31.8 31.8 -0.7 3.79 -3.79 0.00 85.00 30.5 30.5 -0.6 3.79 -3.79 0.00 83.33 29.2 29.1 -0.6 3.78 -3.79 0.00 81.67 27.8 27.8 -0.5 3.77 -3.78 0.00 80.00 26.5 26.5 -0.5 3.75 -3.76 0.00 78.33 25.2 25.2 -0.5 3.73 -3.73 0.00 76.67 23.9 23.9 -0.4 3.69 -3.70 0.00 75.00 22.6 22.6 -0.4 3.65 -3.65 0.00 73.33 21.4 21.4 -0.4 3.59 -3.60 0.00 71.67 20.1 20.1 -0.3 3.53 -3.53 0.00 70.00 18.9 18.9 -0.3 3.45 -3.45 0.00 68.33 17.7 17.7 -0.3 3.36 -3.36 0.00 66.67 16.6 16.6 -0.2 3.26 -3.26 0.00 65.00 15.4 15.4 -0.2 3.14 -3.14 0.00 63.33 14.4 14.4 -0.2 3.01 -3.01 0.00 61.67 13.4 13.4 -0.2 2.86 -2.86 0.00 60.00 12.4 12.4 -0.1 2.70 -2.70 0.00 58.33 11.5 11.5 -0.1 2.51 -2.52 0.00 56.67 10.6 10.6 -0.1 2.31 -2.32 0.00 55.00 9.8 9.8 -0.1 2.10 -2.10 0.00 53.33 9.2 9.2 -0.1 1.86 -1.87 0.00 51.67 8.6 8.6 -0.1 1.61 -1.61 0.00 50.00 8.0 8.0 -0.1 1.33 -1.33 0.00 49.00 7.8 7.8 -0.1 1.31 -1.31 0.00 48.00 7.5 7.5 -0.1 1.30 -1.30 0.00 47.00 7.2 7.2 -0.1 1.28 -1.29 0.00 46.00 7.0 7.0 -0.1 1.27 -1.27 0.00 45.00 6.7 6.7 -0.1 1.25 -1.25 0.00 40.00 5.4 5.4 0.0 1.17 -1.17 0.00 33.33 3.9 3.9 0.0 1.03 -1.03 0.00 26.67 2.6 2.6 0.0 0.86 -0.86 0.00 20.00 1.5 1.5 0.0 0.68 -0.68 0.00 13.33 0.7 0.7 0.0 0.47 -0.47 0.00 6.67 0.2 0.2 0.0 0.24 -0.24 0.00 0.00 0.0 0.0 0.0 0.00 0.00 0.00 Page H 1 TSTower - v 5.3.2 Tower Analysis Program Licensed to: Global Tower Partners (c) 1997-2012 TowerSoft www.TSTower.com Boca Raton, FL File: C:\Documents and Settings\pnejman\My Documents\Work\NY-5015_011013\NY-5015 SA 011013_ATT.out Contract: Revision: Project: Structural analysis of 90' Flagpole Site: NY-5015 (Orient Point) Date and Time: 1/10/2013 2:30:48 PM Engineer: Mike De Boer Section K: POLE OUTPUT LOAD DATA Load Combination Max Envelope Wind Direction Maximum Elev. Axial Ld. Shear Ld. Torque Bend Mom. (ft) (kips) (kips) (kipsft) (kipsft) 90.00 0.12 0.16 0.00 0.23 88.33 0.12 0.16 0.00 0.50 68.33 0.28 0.26 0.00 0.51 86.67 0.28 0.26 0.00 0.93 86.67 0.45 0.36 0.00 0.93 85.00 0.45 0.36 0.00 1.53 85.00 1.15 2.63 0.00 1.53 83.33 1.15 2.63 0.00 5.91 83.33 1.67 3.57 0.00 5.91 81.67 1.67 3.57 0.00 11.87 81.67 1.84 3.67 0.00 11.87 80.00 1.84 3.67 0.00 17.98 80.00 2.00 3.76 0.00 17.98 78.33 2.00 3.76 0.00 24.13 78.33 2.16 3.86 0.00 24.13 76.67 2.16 3.86 0.00 30.56 76.67 2.33 3.95 0.00 30.56 75.00 2.33 3.95 0.00 37.14 75.00 3.08 5.65 0.00 37.15 73.33 3.08 5.65 0.00 46.57 73.33 3.25 5.74 0.00 46.58 71.67 3.25 5.74 0.00 56.15 71.67 3.43 5.83 0.00 56.16 70.00 3.43 5.83 0.00 65.69 70.00 3.60 5.92 0.00 65.70 68.33 3.60 5.92 0.00 75.56 68.33 3.82 6.01 0.00 75.57 66.67 3.82 6.01 0.00 85.59 66.67 4.05 6.10 0.00 85.60 65.00 4.05 6.10 0.00 95.77 65.00 4.53 7.80 0.00 95.78 63.33 4.53 7.80 0.00 108.79 63.33 4.76 7.88 0.00 108.81 61.67 4.76 7.88 0.00 121.70 61.67 4.99 7.97 0.00 121.71 60.00 4.99 7.97 0.00 135.00 60.00 5.17 8.04 0.00 135.02 58.33 5.17 6.04 0.00 148.43 58.33 5.35 8.11 0.00 148.45 56.67 5.35 8.11 0.00 161.99 56.67 5.53 8.18 0.01 162.01 55.00 5.53 8.18 0.00 175.66 55.00 6.01 9.86 0.01 175.68 53.33 6.01 9.86 0.01 191.82 53.33 6.19 9.92 0.01 191.84 51.67 6.19 9.92 0.01 208.41 51.67 6.37 9.98 0.01 208.43 50.00 6.37 9.98 0.01 225.10 50.00 6.54 10.08 0.01 225.11 49.00 6.54 10.08 0.01 235.01 49.00 6.72 10.21 0.01 235.02 48.00 6.72 10.21 0.01 245.39 48.00 6.90 10.35 0.01 245.39 47.00 6.90 10.35 0.01 255.56 47.00 7.07 10.49 0.01 255.56 46.00 7.07 10.49 0.01 266.21 46.00 7.41 11.15 0.01 266.21 Page K 1 TSTower - v 5.3.2 Tower Analysis Program Licensed to: Global Tower Partners (c) 1997-2012 TowerSoft www.TSTower.com Boca Raton, FL File: C:\Documents and Settings\pnejman\My Documents\Work\NY-5015_011013\NY-5015 SA 011013_ATT.out Contract: Revision: Project: Structural analysis of 90' Flagpole Site: NY-5015 (Orient Point) Date and Time: 1/10/2013 2:30:48 PM Engineer: Mike De Boer 45.00 7.41 11.15 0.01 277.17 45.00 8.11 12.08 0.01 277.17 40.00 8.11 12.08 0.01 337.73 40.00 9.45 12.85 0.01 337.74 33.33 9.45 12.85 0.01 423.22 33.33 10.96 13.71 0.01 423.23 26.67 10.96 13.71 0.01 514.39 26.67 12.17 14.52 0.01 514.40 20.00 12.17 14.52 0.01 610.98 20.00 13.40 15.29 0.01 610.99 13.33 13.40 15.29 0.01 713.25 13.33 14.64 16.03 0.01 713.25 6.67 14.64 16.03 0.01 819.97 6.67 15.85 16.77 0.01 819.97 0.00 15.85 16.77 0.01 931.63 Base 16.44 17.16 0.01 931.63 Page K 2 TSTower - v 5.3.2 Tower Analysis Program Licensed to: Global Tower Partners (a) 1997-2012 TowerSoft www.TSTower.com Boca Raton, FL File: C:\Documents and Settings\pnejman\My Documents\Work\NY-5015_011013\NY-5015 SA 011013_ATT.out Contract: Revision: Project: Structural analysis of 90' Flagpole Site: NY-5015 (Orient Point) Date and Time: 1/10/2013 2:30:48 PM Engineer: Mike De Boer Section L: STRENGTH ASSESSMENT DATA Load Combination Max Envelope Wind Direction Maximum Elev. Axial Ld. Axial Cap Moment Mom. Cap Assess. (ft) (kips) (kips) (kipsft) (kipsft) 90.00 0.12 933.24 0.23 228.07 0.001 88.33 0.12 933.24 0.50 228.07 0.002 88.33 0.28 933.24 0.51 228.07 0.002 86.67 0.28 933.24 0.93 228.07 0.004 86.67 0.45 933.24 0.93 228.07 0.004 85.00 0.45 933.24 1.53 228.07 0.007 85.00 1.15 933.24 1.53 228.07 0.008 83.33 1.15 933.24 5.91 228.07 0.027 83.33 1.67 933.24 5.91 228.07 0.027 81.67 1.67 933.24 11.87 228.07 0.054 81.67 1.84 933.24 11.87 228.07 0.054 80.00 1.84 933.24 17.98 228.07 0.080 80.00 2.00 933.24 17.98 228.07 0.081 78.33 2.00 933.24 24.13 228.07 0.108 78.33 2.16 933.24 24.13 228.07 0.108 76.67 2.16 933.24 30.56 228.07 0.136 76.67 2.33 933.24 30.56 228.07 0.136 75.00 2.33 933.24 37.14 228.07 0.165 75.00 3.08 933.24 37.15 228.07 0.166 73.33 3.08 933.24 46.57 228.07 0.207 73.33 3.25 933.24 46.58 228.07 0.207 71.67 3.25 933.24 56.15 228.07 0.249 71.67 3.43 933.24 56.16 228.07 0.249 70.00 3.43 933.24 65.69 228.07 0.291 70.00 3.60 933.24 65.70 228.07 0.291 68.33 3.60 933.24 75.56 228.07 0.335 68.33 3.82 933.24 75.57 228.07 0.335 66.67 3.82 933.24 85.59 228.07 0.379 66.67 4.05 933.24 85.60 228.07 0.379 65.00 4.05 933.24 95.77 228.07 0.424 65.00 4.53 933.24 95.78 228.07 0.424 63.33 4.53 933.24 108.79 228.07 0.481 63.33 4.76 933.24 108.81 228.07 0.482 61.67 4.76 933.24 121.70 228.07 0.538 61.67 4.99 933.24 121.71 228.07 0.538 60.00 4.99 933.24 135.00 228.07 0.597 60.00 5.17 933.24 135.02 228.07 0.597 58.33 5.17 933.24 148.43 228.07 0.656 58.33 5.35 933.24 148.45 228.07 0.656 56.67 5.35 933.24 161.99 228.07 0.715 56.67 5.53 933.24 162.01 228.07 0.716 55.00 5.53 933.24 175.66 228.07 0.776 55.00 6.01 933.24 175.68 228.07 0.776 53.33 6.01 933.24 191.82 228.07 0.847 53.33 6.19 933.24 191.84 228.07 0.847 51.67 6.19 933.24 208.41 228.07 0.920 51.67 6.37 933.24 208.43 228.07 0.920 50.00 6.37 933.24 225.10 228.07 0.993 50.00 6.54 1898.92 225.11 1413.29 0.162 49.00 6.54 1902.32 235.01 1420.14 0.169 49.00 6.72 1902.32 235.02 1420.14 0.169 48.00 6.72 1905.70 245.39 1426.99 0.175 48.00 6.90 1905.70 245.39 1426.99 0.175 47.00 6.90 1909.08 255.56 1433.85 0.181 47.00 7.07 1909.08 255.56 1433.85 0.181 46.00 7.07 1912.43 266.21 1440.71 0.188 46.00 7.41 1912.43 266.21 1440.71 0.188 Page L 1 TSTower - v 5.3.2 Tower Analysis Program Licensed to: Global Tower Partners (c) 1997-2012 TowerSoft www.TSTower.com Boca Raton, FL File: C:\Documents and Settings\pnejman\My Documents\Work\NY-5015_011013\NY-5015 SA 011013_ATT.out Contract: Revision: Project: Structural analysis of 90' Flagpole Site: NY-5015 (Orient Point) Date and Time: 1/10/2013 2:30:48 PM Engineer: Mike De Boer 45.00 7.41 1915.78 277.17 1447.57 0.195 45.00 8.11 1915.78 277.17 1447.57 0.195 40.00 9.45 1917.22 337.74 1450.55 0.237 33.33 9.45 1939.10 423.22 1496.45 0.287 33.33 10.96 1939.10 423.23 1496.45 0.288 26.67 10.96 1960.36 514.39 1542.51 0.338 26.67 12.17 1960.36 514.40 1542.51 0.339 20.00 12.17 1980.98 610.98 1588.71 0.390 20.00 13.40 1980.98 610.99 1588.71 0.390 13.33 13.40 2000.96 713.25 1635.02 0.442 13.33 14.64 2000.96 713.25 1635.02 0.442 6.67 14.64 2020.32 819.97 1681.41 0.494 6.67 15.85 2020.32 819.97 1681.41 0.494 0.00 15.85 2039.05 931.63 1727.85 0.546 Page L 2 TSTower - v 5.3.2 Tower Analysis Program Licensed to: Global Tower Partners (c) 1997-2012 TowerSoft www.TSTower.com Boca Raton, FL File: C:\Documents and Settings\pnejman\My Documents\Work\NY-5015_011013\NY-5015 SA 011013_ATT.out Contract: Revision: Project: Structural analysis of 90' Flagpole Site: NY-5015 (Orient Point) Date and Time: 1/10/2013 2:30:48 PM Engineer: Mike De Boer Section M: SECTION PROPERTIES DATA Elev. Diam. Width Thick. W/t Area S (ft) (in) (in) (in) (in^2) (in^3) 90.0 12.8 1.2 0.500 2.5 19.4 57.01 88.3 12.8 1.2 0.500 2.5 19.4 57.01 88.3 12.8 1.2 0.500 2.5 19.4 57.01 86.7 12.8 1.2 0.500 2.5 19.4 57.01 86.7 12.8 1.2 0.500 2.5 19.4 57.01 85.0 12.8 1.2 0.500 2.5 19.4 57.01 85.0 12.8 1.2 0.500 2.5 19.4 57.01 83.3 12.8 1.2 0.500 2.5 19.4 57.01 83.3 12.8 1.2 0.500 2.5 19.4 57.01 81.7 12.8 1.2 0.500 2.5 19.4 57.01 81.7 12.8 1.2 0.500 2.5 19.4 57.01 80.0 12.8 1.2 0.500 2.5 19.4 57.01 80.0 12.8 1.2 0.500 2.5 19.4 57.01 78.3 12.8 1.2 0.500 2.5 19.4 57.01 78.3 12.8 1.2 0.500 2.5 19.4 57.01 76.7 12.8 1.2 0.500 2.5 19.4 57.01 76.7 12.8 1.2 0.500 2.5 19.4 57.01 75.0 12.8 1.2 0.500 2.5 19.4 57.01 75.0 12.8 1.2 0.500 2.5 19.4 57.01 73.3 12.8 1.2 0.500 2.5 19.4 57.01 73.3 12.8 1.2 0.500 2.5 19.4 57.01 71.7 12.8 1.2 0.500 2.5 19.4 57.01 71.7 12.8 1.2 0.500 2.5 19.4 57.01 70.0 12.8 1.2 0.500 2.5 19.4 57.01 70.0 12.8 1.2 0.500 2.5 19.4 57.01 68.3 12.8 1.2 0.500 2.5 19.4 57.01 68.3 12.8 1.2 0.500 2.5 19.4 57.01 66.7 12.8 1.2 0.500 2.5 19.4 57.01 66.7 12.8 1.2 0.500 2.5 19.4 57.01 65.0 12.8 1.2 0.500 2.5 19.4 57.01 65.0 12.8 1.2 0.500 2.5 19.4 57.01 63.3 12.8 1.2 0.500 2.5 19.4 57.01 63.3 12.8 1.2 0.500 2.5 19.4 57.01 61.7 12.8 1.2 0.500 2.5 19.4 57.01 61.7 12.8 1.2 0.500 2.5 19.4 57.01 60.0 12.8 1.2 0.500 2.5 19.4 57.01 60.0 12.8 1.2 0.500 2.5 19.4 57.01 58.3 12.8 1.2 0.500 2.5 19.4 57.01 58.3 12.8 1.2 0.500 2.5 19.4 57.01 56.7 12.8 1.2 0.500 2.5 19.4 57.01 56.7 12.8 1.2 0.500 2.5 19.4 57.01 55.0 12.8 1.2 0.500 2.5 19.4 57.01 55.0 12.8 1.2 0.500 2.5 19.4 57.01 53.3 12.8 1.2 0.500 2.5 19.4 57.01 53.3 12.8 1.2 0.500 2.5 19.4 57.01 51.7 12.8 1.2 0.500 2.5 19.4 57.01 51.7 12.8 1.2 0.500 2.5 19.4 57.01 50.0 12.8 1.2 0.500 2.5 19.4 57.01 50.0 36.4 5.9 0.250 23.7 28.7 256.18 49.0 36.5 5.9 0.250 23.8 28.8 257.74 49.0 36.5 5.9 0.250 23.8 28.8 257.74 48.0 36.6 6.0 0.250 23.8 28.9 259.30 48.0 36.6 6.0 0.250 23.8 28.9 259.30 47.0 36.7 6.0 0.250 23.9 28.9 260.87 47.0 36.7 6.0 0.250 23.9 28.9 260.87 46.0 36.8 6.0 0.250 24.0 29.0 262.45 46.0 36.8 6.0 0.250 24.0 29.0 262.45 45.0 36.9 6.0 0.250 24.1 29.1 264.03 45.0 36.9 6.0 0.250 24.1 29.1 264.03 Page M 1 TSTower - v 5.3.2 Tower Analysis Program Licensed to: Global Tower Partners (c) 1997-2012 TowerSoft www.TSTower.com Boca Raton, FL File: C:\Documents and Settings\pnejman\My Documents\Work\NY-5015_011013\NY-5015 SA_011013_ATT.out Contract: Revision Project: Structural analysis of 90' Flagpole Site: NY-5015 (Orient Point) Date and Time: 1/10/2013 2:30:48 PM Engineer: Mike De Boer 40.0 37.5 6.1 0.250 24.4 29.6 271.99 40.0 37.0 6.0 0.250 24.1 29.2 264.71 33.3 37.7 6.2 0.250 24.6 29.7 275.37 33.3 37.7 6.2 0.250 24.6 29.7 275.37 26.7 38.5 6.3 0.250 25.1 30.3 286.24 26.7 38.5 6.3 0.250 25.1 30.3 286.24 20.0 39.2 6.4 0.250 25.6 30.9 297.32 20.0 39.2 6.4 0.250 25.6 30.9, 297.32 13.3 39.9 6.5 0.250 26.2 31.5 308.61 13.3 39.9 6.5 0.250 26.2 31.5 308.61 6.7 40.6 6.7 0.250 26.7 32.1 320.11 6.7 40.6 6.7 0.250 26.7 32.1 320.11 0.0 41.4 6.8 0.250 27.2 32.6 331.82 Note: w/t values marked with * (asterisk) indicate width to thickness exceeding maximum allowable values by standards. Page M 2 TowerSoft Tower - v 5.3.2 Monopole Analysis Program Licensed to: Global Toner Partners, Boca Raton, FL (c) 1997-2012 TowerSoft, Mississauga, Ontario. Project: Structural analysis of 90' Flagpole Site: HY-5015 (Orient Point) Contract: Engineer: Mike De Boer BASE PLATE DETAILS Rods spacing Ilia. = 47.000 Maximum Base Reactions Axial Load(Kips) = 13.23 Shear Load(Kips) = 17.16 Bending Moment(Kipsft)= 931.63 Torque(Kips f t) = 0.01 Anchor Rod Data I No of rods = 9 Grade = A3 6 Size = 2 in --- --•-- •—•— - ---- Lar * (in) = 2.000 Shear Load(Kips) = 1.91 Axial Load(Kips) = 107. 19 Shear Cap. (Kips) = 61.49 Axial Cap. (Kips) = 108.67 Assessment Ratio = 0.97 Plate Data Inside dial. = 34.880 Thickness(in) = 1.500 Grade = A572 gr.50 Pole dia.i = 41.375 Max. Stress(ksi) = 23.9 Allow. Stress(ksi) = 45.0 0utside dia. = 53.000 � Assessment Ratio = 0.5 Plate Bottom above Concrete * Lar = Length from top of concrete to bottom of anchor rod leveling nut. TSTower - v 5.3.2 Tower Analysis Program Licensed to: Global Tower Partners (c) 1997-2012 TowerSoft www.TSTower.com Boca Raton, FL File: C:\Documents and Settings\pnejman\My Documents\Work\NY-5015_011013\NY-5015_SA 011013_ATT.out Contract: Revision: Project: Structural analysis of 90' Flagpole Site: NY-5015 (Orient Point) Date and Time: 1/10/2013 2:30:48 PM Engineer: Mike De Boer Horizontal DisplacementDianram Max.Envelope(All Loading Cases) Elevation(ft) 90.0 00.0 70.0 60.0 50.0 40.0 0.0 Displacement(in) 8 16 24 31 Appendix 2 TSTower - v 5.3.2 Tower Analysis Program Licensed to: Global Tower Partners (c) 1997-2012 TowerSoft www.TSTower.com Boca Raton, FL File: C:\Documents and Settings\pnejman\My Documents\Work\NY-5015_011013\NY-5015 SA 011013_ATT.out Contract: Revision: Project: Structural analysis of 90' Flagpole Site: NY-5015 (Orient Point) Date and Time: 1/10/2013 2:30:48 PM Engineer: Mike De Boer Bending Moment Diagram Max.Envelope(All Loading Cases) Elevation(ft) 90.0 80.0 70.0 60.0 50.0 40.0 0.0 Moment(Kipsft) 272 544 816 1088 1360 1632 Moment— Capacity Appendix 3 T APPENDIX C Collocation Application T GLOBAL TOWER PARTNERS GTP Collocation Application Check one: New❑ Modification® LEASE#9886 VERSION 1; PLEASE RETURN THIS APPLICATION TO: (E-MAIL IS PREFERRED) GTP Site#: NY-5015 GTP GTP Site Name: Orient Point 750 Park of Commerce Blvd E-Mail: sales@gtpsites.com GTP Date Received: 11-6-12 Suite 300 Revision Dates: 11-6-12,12-11-12 Boca Raton,FL 33487-3612 Office: (561)995-0320 RSM Approval: Charles Laurette 11/16/12 Attn: Leasing Fax: (561)995-0321 APPLICANT/CARRIER INFORMATION Carrier Name: AT&T Contact Name: Katie Jacobs Carrier Site Name: Orient Point Contact Number: 516-557-2398 Carrier Site Number: NYCENY0735 Contact Fax: 516-557-2397 Carrier Legal Entity Name, New Cingular Wireless PCS,LLC Contact Address: 5550 Merrick Road,Suite 302 State of registration: Delaware Massapequa,NY 11758 Type of entity(LP,LLC,Corp) LLC d/b/a/ (If applicable) N/A Notice Address for Lease: 12555 Cingular Way,Alpharetta,GA Contact E-mail: Katie@Brennanshore.com 30004 With copies to: 340 Mount Kemble Ave,Morristown,NJ Additional E-mail: N/A 07960-6656 Carrier Invoice Address: 12555 Cingular Way,Alpharetta,GA Other: N/A 30004 Carrier Invoice Contact- N/A Carrier NOC# 800-832-6662 Name,Title,Phone No. ADDITIONAL CARRIER INFORMATION Leasing Contact Name/Number: Katie Jacobs/516-557-2398 RF Contact Name/Number: Joe Fitzsimmons/ 201 571-0763 Construction Contact Name/Number: Emergency Contact Name/Number: 800-832-6662 SITE INFORMATION Latitude: 41 8 33.55 N Existing Structure Type: Flagpole Longitude: 72 17 58.09 W I Existing Structure Height: 90' Site Address: 1 23300 Main Road,Orient Point,NY 11957 GLOBAL TOWER PARTNERS GTP Collocation Application Antenna E ui 3ment Specifications Sectors 1,2,3 1,2,3 1,2,3 (1,2,3 etc. -if applicable) Equipment Type Panel TMA Diplexer (Panel,Omni,RRU,TMA, Antenna RET,MW Dish etc.) Installation Status Swapping Existing and Proposed (Existing,Proposed etc.) three existing Remaining Kathrein antennas with the below proposed model antenna Rad Center AGL(ft) 75' 75' 75' Equipment Mount Height(ft) 75' 75' 75' Equipment Mount Type Equipment Quantity One antenna Two TMAs per Two per sector per sector—3 sector—6 total —6 total total Equipment Manufacturer Andrew Andrew Kaelus Equipment Model# DBXNH- ETB19G8-TMA DBC0037F1V2 6565A -X Equipment Weight(per item 34.2 Ibs 16 Ibs 6.4 Ibs in Ibs)) Equipment Dimensions 7.1 in x 50.9 15.8 in x 2.9 in x 6.7 x 2.4 x 5.9 (HxWxD) in x 11.9 in 6.9 in Indicate feet or inches TOTAL#of LINES for 12 existing N/A N/A equipment in column lines Line Type 12 existing N/A N/A lines are coax Line Diameter/Size Coax—7/8" N/A N/A Orientation/Azimuth(degrees 75,160,240 N/A N/A from true north) Mechanical Tilt(degrees) 0 N/A N/A TX Frequency 734-746, N/A N/A 869.04- 879.99, 890.01- 891.48,1930- 1940,1965- 1970 RX Frequency 704-716, N/A N/A 824.04- 834.99, 845.01- 846.48,1850- 1860, 1885- 1890 ERP(wafts) 500 W N/A N/A Type of Technology(i.e.3G, LTE, N/A N/A LTE,CMDA etc) GSM/UMTS Will RRU's be installed behind Antennas 0®Yes No GLOBAL TOWER PARTNERS GTP Collocation Application If no, please explain: AT&T is proposing to install the 6 RRHs in the existing licensed equipment area. FIBER: r Yes ' No Who is Provider? PLEASE NOTE-All Equipment Lines are required to be installed inside the tower when space is available. Carriers will be charged an additional$25.00 per line per month if equipment lines are installed on the outside of the tower even though there is available space inside the tower. GTP must approve any installation of lines on the outside of towers prior to installation commencement. GROUND SPACE REQUIREMENTS Total Ground Area Dimensions Required 16 x 28 448 sq ft Generator: ❑Diesel ❑Propane ❑Natural Gas (length x width x height in ft.) Pad Dimension L X W,ft.): Cabinet Pad Dimensions Cabinet Manufacturer Shelter Pad Dimensions Shelter Manufacturer AC POWER REQUIREMENTS Voltage: Total Amperage: Comments: AT&T is proposing to swap the existing 3 Kathrein antennas with 3 new Andrew antennas described in the table above. In addition they will be adding 6 RRHs,6 triplexers, 1 surge arrestor, `1_GPS,to the existing licensed equipment area. They will be keep 6 existing TMAs already in the tower. Keep 1 existing GPS They will add 6 diplexers in the flagpole. Final Configuration on Tower: • 3 Panel Antennas • 12 7/8"coax cables • 6 TMA's • 6 Diplexers Final Configuration on Ground: • 6 RRH's • 6 Triplexers • 2 Surge Arrestor • 2 GPS RF Exposure Analysis for Proposed New Cingular Wireless PCS LLC (AT&T) Antenna Facility Site ID: NYCENY0735 23300 MAIN ROAD, ORIENT, NY 11957 { rq H January 8, 2013 Prepared by Bernard Morgan Senior RF Engineer Bechtel Communications, Inc. New Cingular Wireless PCS,LLC(AT&T) Table of Contents 1. INTRODUCTION................................................................................................................................3 2. SITE DATA...........................................................................................................................................3 3. RF EXPOSURE PREDICTION..........................................................................................................5 4. FCC GUIDELINES FOR EVALUATING THE ENVIRONMENTAL EFFECTS OFRF EMISSION................................................................................................................................5 5. COMPARISON WITH STANDARDS AT STREET LEVEL..........................................................6 6. CONCLUSION AT STREET LEVEL................................................................................................6 7. FCC LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE(MPE)..........................................7 8. EXHIBIT A—INDIVIDUAL SYSTEMS POWER DENSITY BY DISTANCE.............................8 9. ATTACHMENTS............................................................................................................................... 14 10. FOR FURTHER INFORMATION............................................................................................... 15 11. REFERENCES................................................................................................................................ 15 2 New Cingular Wireless PCS,LLC(AT&T) 1. Introduction This report constitutes an RF exposure analysis for the proposed New Cingular Wireless PCS, LLC (AT&T) antenna facility to be located at 23300 MAIN ROAD,ORIENT,NY 11957. This analysis uses site-specific engineering data to determine the predicted levels of radio frequency (RF) electromagnetic energy in the vicinity of the proposed facility and compares those levels with the Maximum Permissible Exposure (MPE) limits established by the Federal Communications Commission. 2. Site Data A-AT&T: AT&T Site Name: NYCENY0735 Number of simultaneously operating channels GSM850:4-4-4 GSM1900:4-4-4 UMTS 1900:2-2-2 UMTS850:2-2-2 LTE700:2-2-2 Type of antenna Andrew DBXNH-6565A-A2M for GSM/UMTS and LTE Power per channel(Watts ERP) GSM850:316 Watts GSM1900:600 Watts UMTS850: 316 Watts UMTS 1900: 600 Watts LTE700: 524 Watts Top of Antennas feet AGL 77' 3" Antenna Aperture Length 4.25 Feet B-Other carriers included in the study: Sprint/Nextel,Verizon and Whip Antennas. 3 New Cingular Wireless PCS,LLC(AT&T) TOP OF EXISTING FLAGPOLE t90'-O" A.G.L. 10 EXISTING NFXTFL ANTENII5 � t85'-0" A.G.L. TOP OF AT&T ANTENNAS (TYP. FOR ALL SECTORS) 10 177'-3" A.G.L. SWAP (1) AT&T ANTENNA FOR PROPOSED LTE AT&T ANDREW ANTENNA (SEE DETAIL 151D&2/A03) I & ADD (2) DIPLEXERS (SEE DETAIL 1/A05) (TYP. ALL SECTORS) OF FXIqTINC VER17ON ANTENNAS I I I I I I EXISTING WHIP ANTENNAS I I I I I I I I EXISTING 90'-0" FLAGPOLE I PROPOSED CPS UNIT ON EXISTING ICE I ROUTE ULESOF EXISTING BRIDGE POST & PROPOSED 1/2- COAX CABLE ROUTED TO BBU (PROVIDE 10' MINIMUM SEPARATION FROM ANY EXISTING I ANTENNA) (SEE DETAIL 1121A/AGS) I EXISTING CPS UNIT TO REMAIN (TYP.) I EXISTING 6'-0" CHAIN LINK FENCE EXISTING AT&T I ANTENNAS � J GRADE LEVEL 0'-0" AGL 4 New Cingular Wireless PCS,LLC(AT&T) 3. RF Exposure Prediction The following equations established by the FCC,in conjunction with the site data,were used to determine the levels of RF electromagnetic energy present in the vicinity of the proposed facility: 0.64*N*EIRP(9) PowerDensity = / R2 (mw/cm2) Eq. I-Far-field Where,N=Number of channels,R= distance in cm from the RC (Emission Center) of antenna, and EIRP(B) =The isotropic power expressed in milliwatts in the direction of prediction point. P lch*N*103 PowerDensity= in 2* *R*h*a/360 (mw/cm2) Eq.2-Near-field Where P;,fch=Input power to antenna terminals in watts/ch,R=distance to center of emission, h=aperture height in meters, a =3 dB band-width of horizontal pattern. 4. FCC Guidelines for Evaluating the Environmental Effects of RF Emission In 1985,the FCC established rules to regulate radio frequency(RF)exposure from FCC licensed antenna facilities. In 1996, the FCC updated these rules, which were further amended in August 1997 by a Second Memorandum Opinion and Order. These new rules represent a consensus of the federal agencies responsible for the protection of public health and the environment, including the Environmental Protection Agency (EPA), the Food and Drug Administration (FDA), the National Institute for Occupational Health and Safety (NIOSH), and the Occupational Safety and Health Administration(OSHA). Under the laws that govern the delivery of wireless communications services in the United States, as amended by the Telecommunications Act of 1996, the FCC has exclusive jurisdiction over RF emissions from personal wireless antenna facilities, which include cellular, PCS, messaging and aviation sites.2 Pursuant to its authority under federal law,the FCC has established rules to regulate the safety of emissions from these facilities. I RF exposure is measured and predicted in terms of power density in units of milliwatts(mW),a thousandth of a watt,or microwatts(/l W),a millionth of a watt,per square centimeter(cm2). Data comparing predictive analysis with on site measurements has demonstrated that power density can be effectively predicted at given locations in the vicinity of a wireless antenna facility. 2 47 U.S.C.Section 332(c)(7)(B)(iv)states that"[n]o State or local government or instrumentality thereof may regulate the placement,construction,and modification of personal wireless service facilities on the basis of the environmental effects of radio frequency emissions to the extent that such facilities comply with the Commission's regulations concerning such emissions." 5 New Cingular Wireless PCS,LLC(AT&T) 5. Comparison with Standards at street level The maximum cumulative power density at the proposed facility represents 1.67 % of the public/uncontrolled MPE limit. This is approximately 320 feet from the antenna facility. Uncontrolled MPE Result 10000 100%of Controlled Limit 100%of Uncontrolled MPE •5%of Uncontrolled MPE 1000 -Predicted Power Density 7nu823T&'4TC9T8Tk E T�6Gf TTSCSCEk6&2T7fIECkBYT4C1TC3 100 , a 10 a-, 0 1 0.1 0.01 0.1 1 10 100 1000 10000 Horizontal Distance From Antenna, ft Cumulative percentage of FCC uncontrolled limit by distance. See Exhibit A for graphic breakdown of individual systems power density by distance. 6. Conclusion at street level This analysis requires a conservative methodology and is based on the simultaneous and continuous operation of all existing and proposed transmitters. In actual operation, many of the transmitters will operate intermittently and therefore the actual levels will be even lower. This analysis shows that the maximum power density in accessible areas at this location is well below the Maximum Permissible Exposure limit established by the FCC. 6 New Cingular Wireless PCS,LLC(AT&T) 7. FCC Limits for Maximum Permissible Exposure (MPE) ',Iar Density (m 9 j A PubI1; 5.01 A 5 A 4. d J t4 b'r pq ry 4 f 0,2 5L—__ -- - 14 0.5 1 N -3.0 30 300 1,500 100,000 Frequency(MHz) New Cingular Wireless PCS,LLC(AT&T) 8. Exhibit A— individual systems power density by distance 10000 AT&T GSM Cellular band 1000 100 xl N 10 a, o a 0.1 0.01 0.1 1 10 100 1000 10000 Horizontal Distance from Antenna at 6ft above ground, ft 10000 AT&T GSM PCS band 1000 100 10 . a 0.1 0.01 0.1 1 10 100 1000 10000 Horizontal Distance from Antenna at 6ft above ground, ft 8 New Cingular Wireless PCS,LLC(AT&T) 10000 AT&T UMTS Cellular band 1000 100 10 o 0.1 0.01 0.1 1 10 100 1000 10000 Horizontal Distance from Antenna at 6ft above ground , ft 10000 AT&T UMTS PCS band 1000 .. . 100 s 10 � c ' 0.1 0.01 0.1 1 10 100 1000 10000 Horizontal Distance from Antenna at 6ft above ground, ft 9 New Cingular Wireless PCS,LLC(AT&T) 10000 AT&T LTE 700Mhz band 1000 .., 100 10 a`) 1 o a 0.1 0.01 0.1 1 10 100 1000 10000 Horizontal Distance from Antenna at 6ft above ground, ft Nextel ESMR band 10000 1000 . 100 ...,a... E 10 0.1 o z.. o n 0.01 0.001 0.1 1 10 100 1000 10000 Horizontal Distance from Antenna@ 6ft above ground, ft 10 New Cingular Wireless PCS,LLC(AT&T) Sprint PCS band 10000 1000 CN 100 S 10 c 1 a) 0.1 0 a 0.01 0.001 0.1 1 10 100 1000 10000 Horizontal Distance from Antenna @ 6ft above ground, ft Verizon 700 band 10000 1000 ' 100 10 N - . 0.1 o M 0.01 0.001 0.1 1 10 100 1000 1 000 Horizontal Distance from Antenna, ft @ 6ft a ove ground level New Cingular Wireless PCS,LLC(AT&T) Verizon Cellular band 10000 1000 100 10 0.1 n 0.01 0.001 0.1 1 10 100 1000 10000 Horizontal Distance from Antenna @ 6ft above ground, ft Verizon PCS band 10000 1000 100 E 3 10 c 1 0.1 o . d 0.01 0,001 0.1 Horizontal Distance from Antenna @16ft above l0000 ground, ft 12 New Cingular Wireless PCS,LLC(AT&T) Whip Antenna 1 10000 1000 E 100 w 10 a� 0.1 a 0.01 0.001 0.1 1 10 100 1000 10000 Horizontal Distance from Antenna, ft @ 6ft above ground level Whip Antenna 2 10000 1000 a .G 100 E S 10 1 0.1 o n, 0.01 0.001 0.1 1 10 100 1000 10000 Horizontal Distance from Antenna, ft @ 6ft above ground level 13 New Cingular Wireless PCS,LLC(AT&T) 9. Attachments ATTACHMENT A. - LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE(MPE) (A) Limits for Occupational/Controlled Exposure Frequency Electric Field Magnetic Field Power Density Averaging Time Range Strength ( ) Strength (H) (S) JE12, IH12 or S (MHz) (V/rn) (A(m) (mW/crn7) (minutes) 0.3-3.0 614 1.63 (10D)* 6 3.0-30 1842/f 4.89/f (goojf)* 6 30-300 61.4 0.163 1.0 6 300-1500 -- -- f/300 6 1500-100,OOD -- -- 5 6 (6) Limits for General Population/Uncontrolled Exposure Frequency Electric Field Magnetic Field Power density Averaging Fine Range Strength (E) Strength (H) (S) J E,1 2, I H 12 or S (MHz) (V/m) (Alm) (n"W/cm2) (minutes) 0.3-1.34 614 1.63 (10D)* 30 1.34-30 824/f 2.19/f (180#2)* 30 30.300 27.5 0.073 0.2 30 300-1500 -- -- f/1500 30 150D-100,ODD -- -- 1.0 30 f= frequency in MHz*Plane-wave equivalent power density NOTE 1: Occupational/controlled limits apply in situations in which persons are exposed as a consequence of their employment provided those persons are fully aware of the potential far exposure and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in situations when an individual is transient through a location where occupational/controlled limits apply provided he or she is Mac aware of the potential for exposure. N©TE 2: General population/uncontrolled exposures apply in situations in which the general public may be exposed,or in which persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or can not exercise control over their exposure. 14 New Cingular Wireless PCS,LLC(AT&T) ATTACHMENT B I_FQRMAtION INFORMATION 1 GwOl.a�wJ'.fheVnK�MM�W e.saraaw..+h.Y!.yc. The signs must be posted in a visible area at each entrance to the site and at NFo.iWAC10 localized areas. fsW.sm.1MV//f.uYasvblwiYsl.' YY1r1eYNY.saY IY.YY.w mw:.0 auimlbap RM—�+.suile. 'frpi.nbrMrOSR..'nNmaY OYYY/aAn,ww.' aY. YnYak'ri4YYYmm00. .YYYwo.r6 aY+N.Y..+.a/uNY 10. For Further Information Additional information about the environmental impact of RF energy from personal wireless antenna facilities can be obtained from the Federal Communications Commission: Dr.Robert Cleveland Federal Communications Commission Office of Engineering and Technology Washington,DC 20554 RF Safety Program: 202-418-2464 Internet address: rfsafety@fcc.gov RF Safety Web Site: www.fcc.gov/oet/rfsafety 11. References [1] The Communications Act of 1934,as amended by the Telecommunications Act of 1996,47 U.S.C. Section 332(c)(7)(B)(iv). [2] Guidelines for Evaluating the Environmental Effects of Radio frequency Radiation,Notice of Proposed Rulemaking,ET Docket 93-62,8 FCC Rcd 2849(1993). [3] Guidelines for Evaluating the Environmental Effects of Radio frequency Radiation,Report and Order,ET Docket 93-62,FCC 96-326,adopted August 1, 1996. 61 Federal Register 41006(1996). [4] Guidelines for Evaluating the Environmental Effects of Radio frequency Radiation, Second Memorandum Opinion and Order,ET Docket 93-62,adopted August 25, 1997. [5] Evaluating Compliance with FCC Guidelines for Human Exposure to Radio frequency Electromagnetic Fields,OET Bulletin 65,August, 1997. 15 PROJECT DESCRIPTION 25736-415-L4-NYCENY0735 IFC Rev 1 MODIFICATION TO EXISTING TELECOM FACILITY COMPRISING OF EQUIPMENT, ANTENNAS AND ASSOCIATED o u CABLES. PROJECT INFORMATION at&t o SITE ADDRESS: 23300 MAIN ROAD CL c ORIENT, NY 11957 - 0 PROPERTY OWNER: THE ORIENT FIRE DISTRICT 23300 MAIN ROAD SITE NUMBER: NYCENY0735 m rE ORIENT, NY 11957 c ^ c r APPLICANT ADDRESS: NEW LING WIRELESS PCS, LLC ('AT&T-) SITE NAME: ORIENT POINT c 0 340 W. KEMBEMBLE AVENUE r MORRISTOWN, NJ 07950 o JURISDICTION: TOWN OF SOUTHOLD PROPERTY TAX ID: SECTION 18, BLOCK 5, LOT 13.8 €� ZONING DISTRICT: R80 C RESIDENTIAL LOW DENSITY DISTRICT VICINITY MAP APPLICABLE BUILDING CODES AND STANDARDS a.n LATITUDE: N 41- 8' 33" (NAD 83) FROM I WN,NJ: o HEAD NORTH-EAST ON US-202 N/MT KEMBLE AVE TOWARDS ZAMROK WAY, TURN RIGHT ONTO a LONGITUDE: W 72' 17' S8" (NAD 83) SUBCONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL MACCULLOCH AVE, TURN LEFT AT THE 3RD CROSS STREET ONTO MILLER RD, TURN RIGHT ONTO COUNTY 9 c ELEVATION: 17't AMSL (NANO 88) ROAD 510/SOUTH ST, CONTINUE TO FOLLOW SOUTH ST, SLIGHT LEFT ONTO MADISON AVE, TURN LEFT TO. CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION. m THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF ° CURRENT USE: TELECOMMUNICATIONS FACILITY MERGE ONTO I-287 N, TAKE EXIT 41A FOR I-80 E TOWARDS NEW YORK CITY, FOLLOW SIGNS FOR I-80 CONTRACT AWARD SHALL GOVERN THE DESIGN. Q PROPOSED USE: TELECOMMUNICATIONS FACILITY E/PATERSQN/NEW YORK AND MERGE ONTO I-80 E, SLIGHT LEFT ONTO INTERSTATE 80 EXPRESS E, o.2 MERGE ONTO INTERSTATE 95 EXPRESS N, CONTINUE ONTO INTERSTATE 95 UPPER LEVEL N. PARTIAL TOLL RF DATA SHEET ROAD, ENTERING NEW YORK, CONTINUE ONTO I-95 N. SUGHT RIGHT ONTO CROSS BRONX EXPY, BUILDING CODE: BUILDING CODE OF NEW YORK STATE - 2010 CONTINUE ONTO 1-295 S, PARTIAL TOLL ROAD, TAKE THE EXIT ONTO CROSS ISLAND PKWY, TAKE EXIT ° 0 30E TO MERGE ONTO 1-495 E/LONG ISLAND EXPY TOWARDS EASTERN LONG ISLAND, TAKE EXIT 71 FOR ELECTRICAL CODE: NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 70-NATIONAL ELECTRICAL CODE fl @ NY-24 TOWARDS HAMPTON BAYS/CALVERTON, TURN RIGHT ONTO NY-24 S/COUNTY ROAD 94 E/EDWARDS DATE ISSUED: 10/04/2012 REVISION: V02 (NEC) - 2008 e n AVE S CONTINUE TD FOLLOW NY-24 S/COUNTY ROAD 94 E, SLIGHT RIGHT TOWARDS COUNTY ROAD 94 $c E/NUGENT DR (SIGNS FOR COUNTY ROAD 51 S), SLIGHT RIGHT ONTO COUNTY ROAD 94 E/NUGENT DR, FIRE/LIFE SAFETY CODE: FIRE CODE OF NEW YOl STATE - 2010 E AT THE TRAFFIC CIRCLE, TAKE THE 3RD EXIT ONTO FLANDERS RD/RIVERHEAD-HAMPTON BAYS RD, CONTINUE TO FOLLOW FLANDERS RD, TURN LEFT ONTO COUNTY RD 105, TURN RIGHT ONTO MAIN RD, LIGHTNING PROTECTION CODE: NFPA 780-2008 LIGHTNING PROTECTION CODE DRAWING INDEX REV TURN LEFT TO STAY ON MAIN RD, TURN RIGHT ONTO NEW YORK 25 E/MAIN RD, DESTINATION WILL BE SUBCONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING ON THE RIGHT STANDARDS. 8 NYCENY0735-T01 TITLE SHEET 1 AMERICAN CONCRETE INSTITUTE (ACI) 318. BUILDING CODE REQUIREMENTS FOR STRUCTURAL NYCENY0735-SP1 SITE PLAN 1 CONCRETE. < < NYCENY0735-A01 SITE PLAN,ANTENNA PLAN&GENERAL NOTES 1�/ 'yC AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), MANUAL OF STEEL CONSTRUCTION, o NYCENY0735-A02 EQUIPMENT PLAN&NOTES - X THIRTEENTH EDITION. t c NYCENY0735-A03 FLAGPOLE ELEVATION& DETAILS 1 = f ANSI/TIA (TELECOMMUNICATIONS INDUSTRY ASSOCIATION) 222-F (1996). STRUCTURAL STANDARDS u a° NYCENY0735-A04 REMOTE RADIO HEAD (RRH)MOUNTING, 1 FOR STEEL ANTENNA TOWER AND ANTENNA SUPPORTING STRUCTURES. g € DC6 EXCEPTION BOX&FIBER MANAGEMENT DETAIL m° NYCENY0735-A05 GPS UNIT MOUNTING,PURCELL CABINET& 1 f SITE TELECOM UNI COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS FOR CATIONS o DIPLEXER MOUNTING DETAILS o INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 81, GUIDE FOR MEASURING o ° NYCENY0735-A06 LTE CONDUCTOR SIZES&ICE BRIDGE DETAIL 1 EARTH RESISTIVITY, GROUND IMPEDANCE, AND EARTH SURFACE POTENTIALS OF A GROUND a NYCENY0735-E01 SYSTEM DIAGRAM 1 SYSTEM o NYCENY0735-E02 RRH WIRING DIAGRAM 1 A IEEE 1100 (1999) RECOMMENDED PRACTICE FOR POWERING AND GROUNDING OF ELECTRONIC EQUIPMENT o MYCENY0735-E03 ELECTRICAL,TVSS NOTES,ABBREV.&SYMBOLS 1 t NYCENY0735-E04 GROUNDING NOTES&DETAILS 1 IEEE C2, NATIONAL ELECTRIC SAFETY CODE - LATEST VERSION o TELCORDIA GR-1275, GENERAL INSTALLATION REQUIREMENTS C q o t ! ANSI T1.311, FOR TELECOM - DC POWER SYSTEMS - TELECOM, ENVIRONMENTAL PROTECTION C FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS REGARDING ram-3 MATERIAL. METHODS OF CONSTRUCTION, OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE o REQUIREMENT SHALL GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT DOCUMENT REVIEW STATUS RO ST AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL GOVERN. o; STATUS NO. o 1.fXACCUMM-WITH MINOR OR NO COMMENTS, CONSTRUCTION MAY PROCEED PROJECT CONTACTS u o 2 NOT ACCEPTED-PLEASE RESOLVE COMMENTS AND RESUBMIT Signedis ar DETAIL _ 100 'eyed b EN ' DN:cn=Goad,Richare y o a G 'R i e h a rWer p=rcoad@bechteLcom 1-10-13 C COMPANY CONTACT NUMBER SCALE: N.T.S. TO1 Date:2013.01.10 13:10:45-05'00' CONSTRUCTION JAYSON GONZALEZ BECHTEL (201) 571-0705 N e RF ENGINEER CONSTRUCTION SA COMPLIANCE ENGINEER RICHARD COAD BECHTEL (201) 571-0730 STRUCTURAL STATEMENT c 5 RF ENGINEER AZAD KARIM BECHTEL (201) 571-0651 cc - 0 0 EXISTING EQUIPMENT PAD HAS EPQ`rANq-IN DDITION OF NEW EQUIPMENT AND NO �z MODIFICATIONS TO THE EXIS �A N ARE REQUIRED. o c Q U q SITE NAME:ORIENT POINT at&t �z BECHTEL ASSOCIATES PROFESSIONAL CORPORATION SITE NUMBER: NYCENY0735 at&t 7 01/10/13 LTE-ISSUED FOR CONSTRUCRON AS � g o 23300 MAIN ROAD TITLE SHEET S A UNIT OF BECHTEL CORPORATION 0 01/04/13 LTE-ISSUED FOR CONSTRUCTION AS a s c ORIENT, NY 11957 5275 WESTVIEW DRIVE0 ND DATE REVWNS BY C xlAr�rR �' a`o c FREDERICK, MD 21703-8386 USA -415 T3-NYCENY0735-TO1 1 °,C- SCAM'AS N= omom W.AS ORAwR[1n Q 1 U a; - / WE 22 r 34 ANN AZL ESSIONP� - B Lia MAIN ROAD (S.R. 25) oa _ N 80' 31' 30' E 3 226.00' - �Q I C Mlto - 0 m t B Z m w� m I PAVED U AREA o C4 co T u e m 79'-7"t P c V) o EXISTING FIRE c 3 STATION I a 75'-5't I o ul c N 1 1 c PAVED PAVED o p I AREA AREA L_ ao Q 1 _ E" p 1 '-N 87-47, 30c 0 o / 224.52`-- - o a m 1 �1 I E 1 1 .63 Ma 1 1 EXISTING 112-Ln 4 l a° 1 PAVED / BUILDING 1 o c I AREA / 1 e Or _ I 1 00 ' \ 1 o� 1 1 m I �\ 1tA $o v(SEE DETAIL 1/AO1) N,N Zt 1 Ito y D 1. a ny • I 1n g n c rn "q `� SUBJECT SITE: ORIENT FIRE 1 o ` DISTRICT SEC71ON 18 11 m $I BLOCK 05 LOT : 13.8 €Y c s 21 1 v 1 1 c I �a 0 o m 1 1 u c 0 u m ---- __--- --S 83'03' 50" E 11 t` rn c n c or a m FULL SCALE 1"=30'-O" r NOTE: BASE MAP INFORMATION OBTAINED SITE PLAN 1 o'Y FROM DRAWINGS PREPARED BY APT NOTE: TO THE LL��0 EDGE, THE 30 1s o 30 so FT oz° ENGINEERING, DATED 03/07/12 AND LAST SCALE: 1 30'—O" SP1 PROPOSED E M4 I Y AT&T UPDATED ON 04/06/12 AND A SITE VISIT WILL HAVE 0 EX G HALF SCALE 1"=60'-0" 00 o PERFORMED BY BECHTEL ON 05/26/2012. NOISE L ISf I €m ® at&t o PROFESSIONAL ASSOCIATES SITE NAME:ORIENT POINT CORPORATION SITE NUMBER: NYCENY0735 ��e 0 8 6c 1 01/10/13 UE-ISSUED FOR CORSIRUC110N 4- k 1` SffE PLAN G 23300 MAIN ROAD A UNIT OF BECHTEL CORPORATION o 01/04/13 UE-ISSUED FOR CONSIRUCi1DN Cl L c 3 ORIENT, NY 11957 o+a� � 5275 WESTVIEW DRIVE Ro DATE REvwaNs 9Y ����a'+= FREDERICK. MD 21703-8386 USA w tleEa Ry U dQ SrA'AS Nolen 9)ts1a1✓tn t11:As MWN BY: Q 1 7. -415 T3-NYCENY0735 SP1 1 512E 22=a 4-.ANSI AROFESSfON��� H GENERAL NOTES L m 1. FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL EXISTING FIRE HOUSE APPLY: CONTRACTOR - BECHTEL 3 a SUBCONTRACTOR - GENERAL CONTRACTOR (CONSTRUCTION) e OWWIRELESS ("AT&T") OEM - ORIGINAL EQUIPMENT MANUFACTURER 0 2. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING SUBCONTRACTOR SHALL VISIT THE CELL °aSITE TO FAMILIARIZE WITH THE a o i BE ACCOMPLISHED AS SHOWN ONI�HEGCONSTRUCTION DRAWINGSNFI ANY DISCREPANCY WORK CAN EXISTING FOUND SHALL BE BROUGHT TO THE ATTENTION OF CONTRACTOR. �I VERIZON o_ EQUIPMENT EXISTING c SHELTER N 3. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL $ L.—. rt � • • • GENERATOR � APPLICABLE CODES, REGULATIONS, AND ORDINANCES. SUBCONTRACTOR SHAM ISSUE ALL e m EXISTING CONCRETE APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND r PAD LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. � u 4. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY a ROPOSED GPS UNIT ON EXISTING ICE BRIDGE POST COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE - & PROPOSED 1/2' COAX CABLE ROUTED TO BBU REGULATIONS. n (PROVIDE 10' MINIMUM SEPARATION FROM ANY c n EXISTING ANTENNA) (SEE DETAIL 1121A/A05) EXISTING 5. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, ° n a AT&T ICE r' APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON c EXISTING NEXT BRIDGE EQUIPMENT SHELTER EXISTING FLAGPOLE THE DRAWINGS. EXISTING 6. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH o U i AT&T EXISTING AT&T CABINETS MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE •q EQUIPMENT r' CABINETS EXISTING VERIZON CSC CABINET 7. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE c SUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE ° I EXISTING CONTRACTOR. -@ POWER & u n TELCO B. SUBCONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUIT, POWER AND T1 CABLES, u-- EXISTING AT&T GROUNDING CABLES AS SHOWN ON THE POWER, GROUNDING AND TELCO PLAN DRAWING. v m E UIPMENT PAD EXISTING TRANSFORMER SUBCONTRACTOR SHALL UTILIZE EXISTING TRAYS AND/OR SHALL ADD NEW TRAYS AS 1 NECESSARY. SUBCONTRACTOR SHALL CONFIRM THE ACTUAL ROUTING WITH THE CONTRACTOR. m . ROUTING OF TRENCHING SHALL BE APPROVED BY CONTRACTOR. �a THE SUBCONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, EXISTING FENCE LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT c EXISTING GATE 1 SUBCONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. oa c Or AD3 10. SUBCONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH m° AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS L FULL SCALE 1/B"=1'-0" REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. .. o` SITE PLAN 1 e o rt is Ft 11 SUBCONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. t c SCALE: 1/8"=1'-0" A01 HALF SCALE 1/is"=t'-0" $ € 12. ALL CONCRETE REPAIR WORK SHALL BE DONE IN ACCORDANCE WITH AMERICAN CONCRETE M.2 ,. INSTITUTE (ACI) 301.N m 13. ANY NEW CONCRETE NEEDED FOR THE CONSTRUCTION SHALL HAVE 4000 PSI STRENGTH AT o r 28 DAYS UNLESS OTHERWISE SPECIFIED. ALL CONCRETING WORK SHALL BE DONE IN ACCORDANCE WITH ACI 318 CODE REQUIREMENTS. a 0 o w EXISTING FLAGPOLE 14. ALL STRUCTURAL STEEL WORK SHALL BE DONE IN ACCORDANCE WITH AISC SPECIFICATIONS. g rn SEGjOR "P 15. CONSTRUCTION SHALL COMPLY WITH SPECIFICATION 25736-000-3PS-AOOZ-00001, GENERAL CONSTRUCTION SERVICES. 0 1 °'• EXISTING (2) MHA'S TO ��� 16. SUBCONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO c ° REMAIN (TYP EACH SECTOR) Lam, COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE o DRAWINGS MUST BE VERIFIED. SUBCONTRACTOR SHALL NOTIFY THE CONTRACTOR OF ANY a , DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. a� SWAP (1) AT&T ANTENNA FOR PROPOSED LIE AT&T ° ANDREW ANTENNA (SEE DETAIL 1510&2/AO3) & 17. THE EXISTING CELL SITE IS IN FULL COMMERCIAL OPERATION. ANY CONSTRUCTION WORK 'o' FGSOA ADD (2) DIPLEXERS (SEE DETAIL 1/A05) (SECTOR A) EXISTING EQUIPMENBY T MFUST BE COORDINATED WITH LL NOT DISRUPT THE SCONTRACTOR.TING L ALSO, WORK MAY BE OPERATION. ANY WORK ON S SCHEDULED FOR AN APPROPRIATE MAINTENANCE WINDOW USUALLY IN LOW TRAFFIC PERIODS 'Jt AFTER MIDNIGHT. SWAP (1) AT&T ANTENNA FOR PROPOSED LTE AT&T 'o SWAP (1) AT&T ANTENNA FOR PROPOSED LTE ANDREW ANTENNA ((SEE DETAIL 1510&2/AO3) & 18. SINCE THE CELL SITE MAY BE ACTIVE, ALL SAFETY PRECAUTIONS MUST BE TAKEN WHEN n o AT&T ANDREW ANTENNA (SEE DETAIL 1510&2/AO3) 0�1� ADD (2) DIPLEXERS (SEE DETAIL 1/A05) (SECTOR 8) WORKING AROUND HIGH LEVELS OF ELECTROMAGNETIC RADIATION. EQUIPMENT SHOULD BE NOTE: � & ADD (2) DIPLEXERS (SEE DETAIL 1/A05) m, SHUTDOWN PRIOR TO PERFORMING ANY WORK THAT COULD EXPOSE THE WORKERS TO LTE ANTENNA AZIMUTHS SHOWN ARE PRELIMINARY rn AND MAY NOT REFLECT FINAL RF DESIGN. REFER (SECTOR C) DANGER. PERSONAL RF EXPOSURE MONITORS ARE REQUIRED TO BE WORN TO ALERT OF ANY c TO LATEST RF DATA SHEET FOR FINAL LTE DANGEROUS EXPOSURE LEVELS. ri ANTENNA SPECIFICATIONS, AZIMUTHS, TILTS, ETC. o$ C4 L FULL SCALE 3/4"=1'-0" c NOTES: �. 100 c0 1. ANTENNA ORIENTATION/AZIMUTHS SHALL BE FIELD VERIFIED. ANTENNA PLAN 2 1z" o t 2 3 F7 T6r A01 `Z 2. EQUIPMENT/ANTENNAS BY OTHERS NOT SHOWN FOR CLARITY. : N• o SCALE 3/4"=1'-0" A01 HALF SCALE 3/8"=1'-0" d A U•f°-� s€� G BECHTEL ASSOCIATES SITE NAME: ORIENT POINT at&t PROFESSIONAL CORPORATION SITE NUMBER: NYCENY0735 Q� L.: � A °` 23300 MAIN ROAD atVC� 1 01/10/13 LIE FOR CONSTRUCTION As G _ j SITE PLAN, ANTENNA PLAN & A UNIT OF BECHTEL CORPORATION r Y GENERAL NOTES t c« ORIENT, NY 11957 O OI/04/13 LTE-MUM FOR CONSITIUCUON AS ar a. rn 3 L 5275 WESTVIEW DRIVE 1 i, No DATE REwstoNs FREDERICK. MD 21703-8386 USA er �� NCR �+�Y073MASER �v Un< 3 a`I a o sruc•A,NOt[O EESANm Of.AS TMI/IN ey; r~�-�" %2573 -415 T3-NYCENY0735-A01 1 Q5439 >"! 5 z a S A 4%'1r ��FESSIO�P�' • CONSTRUCTION NOTES 1. FIELD VERIFICATION: co SUBCONTRACTOR SHALL FIELD VERIFY SCOPE OF WORK, AT&T ANTENNA PLATFORM LOCATION AND ANTENNAS TO BE REPLACED. t —INSTALL (6) PROPOSED RRH'S 2. COORDINATION OF WORK: •3 a & (6) TRIPLEXERS ON PROPOSED - SUBCONTRACTOR SHALL COORDINATE RF WORK AND PROCEDURES WITH CONTRACTOR. H-FRAME. (SEE DETAIL 111OD/A04) 0 3. CABLE LADDER RACK: o INSTALL NEW ICE BRIDGE WITH ICE SUBCONTRACTOR SHALL FURNISH AND INSTALL CABLE LADDER RACK, CABLE TRAY, AND BRIDGE POST (SEE DETAIL 1154/AO6) CONDUIT AS REQUIRED TO SUPPORT CABLES. 0 ` PROPOSED GPS UNIT ON EXISTING ICE BRIDGE DETAIL o EXISTING GPS UNIT TO �' m o REMAIN (TYP.) POST & PROPOSED 1/2' COAX CABLE + 101 SCALE:N.T.S. c v ROUTED TO BBU (PROVIDE 10' MINIMUM j + + A02 c o INSTALL DC6 EXCEPTION BOX & FIBER SEPARATION FROM ANY EXISTING ANTENNA) r o MANAGEMENT BOX ON EXISTING COAX (SEE DETAIL 1121A/AO5) o m SUPPORT RACK �+ + STRUCTURAL STEEL NOTES (SEE DETAIL 1&1137/AO4) O + + ++ + 1. ALL STEEL WORK SHALL BE PAINTED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS €v + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + AND IN ACCORDANCE WITH ASTM A36 UNLESS OTHERWISE NOTED. + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + 0 2. ALL WELDING SHALL BE PERFORMED USING E70XX ELECTRODES AND WELDING SHALL o t� �f - k_t _t + �f — +-- -+ � t� �� + +—�¢ + CONFORM TO AISC. WHERE FILLET WELD SIZES ARE NOT SHOWN, PROVIDE THE MINIMUM CIA +r+ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + SIZE PER TABLE J2.4 IN THE AISC "MANUAL OF STEEL CONSTRUCTION'. PAINTED -` + + + + + + + + + + + + + + + + + + + + + + + -''�� + + + + + + + SURFACES SHALL BE TOUCHED UP. v + r°a2 3. BOLTED CONNECTIONS SHALL BE ASTM A325 BEARING TYPE o V I (3/4"0) CONNECTIONS AND SHALL HAVE MINIMUM OF TWO BOLTS UNLESS NOTED c Y *I t �� OTHERWISE. c � 4. NON-STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8" DIA. ASTM A 307 ° + i BOLTS UNLESS NOTED OTHERWISE. v @ + c 'a +I+ 5. INSTALLATION OF CONCRETE EXPANSION/WEDGE ANCHOR, SHALL BE PER MANUFACTURER'S • EXISTING EXISTING EXISTING WRITTEN RECOMMENDED PROCEDURE. THE ANCHOR BOLT, DOWEL OR ROD SHALL CONFORM io ARGUS EXISTING EXISTING EXISTING v E + TO MANUFACTURER'S RECOMMENDATION FOR EMBEDMENT DEPTH OR AS SHOWN ON THE 7E21 NOKIA NOKIA PURCELL CCI LUCENT POWER 850 1900 DB MCPA RxAIT UMTS DRAWINGS. NO REBAR SHALL BE CUT WITHOUT PRIOR CONTRACTOR APPROVAL WHEN �+ CABINET CABINET CABINET CABINET DRILLING HOLES IN CONCRETE. SPECIAL INSPECTIONS, REQUIRED BY GOVERNING CODES, SHALL BE PERFORMED IN ORDER TO MAINTAIN MANUFACTURER'S MAXIMUM ALLOWABLE + + LOADS. EXISTING I , AC PANEL 6. ALL EXPANSION/WEDGE ANCHORS SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED. m F F ,% ,� ; THE ANCHOR BOLT DOWEL AND ROD SHALL BE STAINLESS STEEL WITH STAINLESS STEEL c I of WASHERS. + I I DETAIL SCALE: N.T.S. t ° $` 11 1 Z'o LI= °w O a' PROPOSED PURCELL FLXI6WS o CABINET, STACKED ON TOP OF EXISTING PURCELL CABINET 0.0 (SEE DETAIL 1117/A05) o EXISTING AT&T CONCRETE SLAB • �•' A. 'c o sa - -or v INSTALL NEW ICE BRIDGE WITH ICE c 2 BRIDGE POST (SEE DETAIL 1154/A06) ° 22'-2" e�y C O� C °n c EXISTING TELCO BOX Ema 0 0 o n_« IE rn c c Oy c L NOTE: FULL SCALE 3/4"=1'-0" Z PRESENTLY THERE ARE 5 RECTIFIERS, UPON THE EQUIPMENT PAD 1 12' 0 1 2 3 Fr 2 z COMPLETION OF THE LTE UPGRADE, THERE SHOULD SCALE: 3 4"=1'-O" A02 3/8"=1'-0" oBE A TOTAL OF 7 RECTIFIERS SHOULD BE PRESENT, / ` 2 NEW RECTIFIERS SHOULD BE ADDED BY LIE HALF SCALE rG �iD M• �- 0.2 s at&t G 0 €o BECHTEL ASSOCIATES SITE NAME:ORIENT POINT �' PROFESSIONAL CORPORATION SITE NUMBER: NYCENY0735 �}Q O c o A UNIT OF BECHTEL CORPORATION 23300 MAIN ROAD `O� 1 01/10/13 tre-ISSUED FOR CONST sucnON AS ! '; EQUIPMENT PLAN & NOTES n 0 01/04/13 LTE-6SIlm FOR COfblRUCnON A5 f L c" i 5275 WESTVIEW DRIVE ORIENT, NY 11957 0NO 0117E REVISIONS BY .k REV a,o-'c - FREDERICK, MD 21703-8386 USA 10 DRAwm NAM 0.� SCAM AS NOTED DESCe®Bo A9 0RA1M BY. 5>~3�-415 T3-NYCENY0735-A02 1 CA 43 - WEzz . » 4151 0 Y R�FESSIO��P�� a 6.7" 5.1" 2"0 - 4.5"0 TOP OF EXISTING FLAGPOLE o a 2"0 - 4.5"0 MOUNTING POLE *90'-0" A.G.L. m 0 MOUNTING POLE I � 4.7" (MIN.) 3.5 i M 17.6" (MAX) 0 7" ¢ OF EXISTING NEXTEL ANTENNAS �e m 00 O O m TOP OF AT&T ANTENNAS ml° ® ql (TYP. FOR ALL SECTORS) c°o I m� I I ±77'-3" A.G.L. IZ SWAP (1) AT&T ANTENNA FOR PROPOSED LTE AT&T ANDREW r I I I & ADD(2) DIP(EXERSN(SEE DETAIL I/A05)A (SEE DETAIL �2/A03) I (TYP. ALL SECTORS) q OF EXISTING VERIZON ANTENNAS MECHANICAL SPECIFICATIONS: t65'-O" A.G.L. c^ WEIGHT = 5.5kg/12.11bs c N YMATERIAL = GALVANIZED STEEL D xl 0.7" m U p I o z I O p Ki N M Z 6 ( EXISTING WHIP o E 3.5` ; I ANTENNAS FRONT ELEVATION SIDE ELEVATION (OR APPROVED BY THE ENGINEER) $ c I POWERWAVE(7256.00) HEAVY DUTY << TILT BRACKET KIT s o i -a.B A03 SCALE: N.T.S. 1) 00 to r 6.5" I L ° 8 € I EXISTING 90'-0" FLAGPOLE m o $� I m � I C ' Ia , ~ PROPOSED GPS UNIT ON EXISTING ICE I ROUTE OF EXISTING n rn I CABLES o'C o m FRONT BRIDGE POSE do PROPOSED 1/2" COAX 't N CABLE ROUTED TO BBU (PROVIDE 10' I ° MINIMUM SEPARATION FROM ANY EXISTING _`C o ANTENNA) (SEE DETAIL 1121A/AO5) °L I z. v_°a EXISTING GPS UNIT TO o M REMAIN (TYP.) 0 01 EXISTING 6'-0" CHAIN o¢ LINK FENCE EXISTING AT&T I c ANTENNAS FRONT ELEVATION SIDE VIEW J E ° / a O ° ;, MECHANICAL CHARACTERISTICS FE c WEIGHT: 33.951b (15.40kg) NOTE:ANTENNA CONFIGURATION ri AND A23MUTHS TO BE FIELD VERIFIED. WIND LOAD (0150 km/h): (413.4N) N MAX. WIND SPEED: 150mph (241.4 km/h) im GRADE LEVEL ffm[a €s LTE ANTENNA 0'-0" AGL 4FULL SOCALE a 3/1 s e 1'-0;Z Fr o 0 2 DBXNH-6565A-A2M FLAGPOLE ELEVATION 1 c /�+ A03 SCALE:3/16" = 1'-0" LE3 t O f ry iz c SCALE: N.T.S. �V til, HALF SCALE 3/32"=l'-O" 0.2 r€� SITE NAME:ORIENT POINT 2 a BECHTEL ASSOCIATES A ® at&t r- PROFESSIONAL CORPORATION SITE NUMBER: NYCENY0735 } 'ray o C` 23300 MAIN ROAD LI at&t 1 01/10/ LTE-tssum FOR CONSTRUCTION As RC LAGPOLE ELEVATION & DETAILS y4 a ® A UNIT OF BECHTEL CORPORATION tlr' c c. ORIENT, NY 11957 0 H01/04/JJ3LTE-65Um FOR CONSTRUCTION AS (rn 3t 5275 WESTVIEW DRNENO REVI90NS BY �- DRAM►NT"� REY FREDERICK, MD 21703-8386 USA 0 `aa ac M a Norm DESM0 er:AS un,1wN ern .� 29�- -415 T3-NYCENY0735-AO3 1 {'/• WF 22 a 34 ANSI AR0. torAP' EXISTING ICE PIPE CAP BRIDGE POST (TYP.) .0 rS ) DC6 EXCEPTION BOX ICE BRIDGE WIDTH PROPOSED FIBER (SEE DETAILS 1137/A04) MANAGEMENT BOX 3. DIPLEXER I I 0 3 1/2.0 ICE —' BRIDGE POST ( I I I I I I I I I I I s= (TYP) ( I I I I I I I I I I I mL 0o o o = o co rr .I a °0] I`- aTco r----I ID r----i r— —� 0 3 € . TO ANTENNA ,o P1000 UNISTRUT I 700 1 1 700 1 1 700 M FIBER ALARM (+45 DEGREE) -eQ CHANNEL RRH RRH RRH ENTRY CABLE PORT or OR EQUIVALENT I FRONT I I FRONT 1 1 IRONY I 1 l 1/2' COAXIAL CABLE W/ (TYP) I I I I I I 7/16 DIN-MALE CONNECTORS • O O c�1a-s O AISG Tx 1x/Rm ON BOTH ENDS (2 TYP) L---J L---J L— —J Cx AW » (IF USED NA o chi +,o FOR RET) (�4 DEGREE} UNISTRUT �) O tD 2E o 'a ,., CONNECTION U MON20 OTx MON1 PORT m ENTRY GROUND 91 DC r----1 r---� r— —� RRH BOTTOM VIEW RRH TOP VIEW ° I I I I I I DC POWER SURGE PROTECTION, v a I AWS I I AWS I I AWS I n SIZE AND WEIGHT TABLE i x I :z I RRHI I RHI I RHI FIBER MANAGEMENT BOX rrr FRONT FRONT CABLE WEIGHT HEIGHT MOUNTING DETAILS RRH WIDTH DEPTH MANAGEMENT COVER W/O BRACKET SCALE: N.T.S. A04 L---J L---J L---J RRH 700 MHz v 12.2' 10.8' 21' 51 LBS. c� • M 2X40 (60W) 15.220' cc G rm, ' RRH AWS 43 LBS. 14.273' 6.370' 6 ` (12- MIN. ix •x 1/4-) 2X40 (BOW) 12- 9' 25' (W/O SOLAR SHIELD) 6.273' c u t 12.006" mI 10 NOTE: DIMENSIONS INCLUDE MOUNTING BRACKET, SOLAR SHIELD AND CONNECTORS. m € I F' I R• M U 0 I__I MINIMUM CLEARANCE TABLE 21 AR 0 0 12'0 PLAIN RRH CABINET C II CHNESCES COMMENTS c CONCRETE OR I? o SAKRETE PIER FRONT 36' INSTALLATION ACCESS ny `o o, �IQIE$: REAR 2- ZERO REAR CLEARANCE IS ALLOWED USING g 70 10.28' m o•� 1. SUBCONTRACTOR SHALL SUPPLY AND INSTALL UNISTRUT(OR EQUIVALENT) MOUNTING CHANNELS. SUPPLIED MOUNTING BRACKETS ,� n a o; n 0 (6 CABLE 2. SUBCONTRACTOR SHALL SUPPLY AND INSTALL ICE BRIDGE POSTS AS REQUIRED. (4) 0 14' = $ LEFT 4' AIR FLOW TO 0.65' O 3. COAX BRIDGE POSTS SHALL BE 3 1/2'0.D. SCHED. 40 PIPE (ASTM-A36, A53 OR EQUIVALENT). CABLE 0 c TOP 12' AIR FLOW o 0 v= 4. SUBCONTRACTOR SHALL SUPPLY (BUT NOT INSTALL) 3/8.0 UNISTRUT BOLTING HARDWARE AND I- O a BOTTOM 12' CONDUIT ROUTING A c SPRING NUTS. TYPICAL FOUR PER RRU. SUBCONTRACTOR SHALL BAG THE BOLTING HARDWARE u°F AND HANG FROM INSTALLED UNISTRUT FRAME. } c a 5. SPACING MAY VARY BASED ON SELECTED EQUIPMENT. ADJUSTMENTS TO SPACING WILL BE MADE ALCATEL—LUCENT 9442 f c BY RRU INSTALLER. ° REMOTE RADIO HEAD (RRH) 313'0 HOLES E> 6. NO PAINTING OF THE RRU OR SOLAR SHIELD IS ALLOWED. R()XTECP) B ° NOTE@ .9 1RADIO HEAD RRH`` RACK DETAIL RAYCAP MODEL DC6-48-60-0-1E IS FITTED REMOTE (RRH) WITH (2) 2-INCH CONDUIT FITTINGS IN PLACE (.ON GRADE W/DIPLEXER51 OF THE ROXTEC BLOCKS. N p RAYCAP DC6-48-60-0-1 B-01 o X RRH MOUNTING FOR SECTORS A,B&C 1110D ALCATEL-LUCENT 9442 REMOTE RADIO HEAD (RRH) DC POW§&4WWfi6&ROTECTION 113 z SCALE: N.T.S. A04 SCALE: N.T.S. A04 SCALE: gor lytA04 V w SITE NAME:ORIENT POINT �G ® 8t&t BECHTEL ASSOCIATES o PROFESSIONAL CORPORATION SITE NUMBER: NYCENY0735 ��Q E OTE RADIO HEAD (RRH) MOUNTING. n OC c� 1 01/10/13 L7E-65UED FOR CONSIRUC0011 AS o ° 23300 MAIN ROAD � imp SAWA UNIT OF BECHTEL CORPORATION MANAGEMENT BOX de DC POWER SURGE rn;t 5275 WESMEW DRIVE ORIENT, NY 11957 O 01/04/13 LIE-ISSUED FOR CONSO2UCIION AS C PROTECTION DETAILS a FREDERICK, MD 21703-8386 USA No DATE REMSIONS BI B��+ m C.0) a� roue As NUfM ��up AS DRAWN Or: 415 T3-NYCENY0735-A04 1 5439. SIZE 22 • 34 ANSI O ESSIONP"V O� m ° t O CL c METAL STRAP. t e HOLE569'0 SUBCONTRACTOR TO PROVIDE (TYP) JUMPER TO 'o i( GPS UNIT ANTENNA m � INSTALL WEATHER PROOFING I j ET INSTRUCTIONSEWS PER UNIT MANUF. COLLAR R DIPLEXER o 'gi I I 1- (1-5/16- O.D.) X 3'-0' MAX. SCROREyyD PROVIDE APPLICABLE GALV. STEEL OR ALUM. MOUNTING GROUND WIRE PIPE-TO-PIPE CLAMP PIPE TO ANTENNA GROUND CABLE CLAMP (BURNDY ANTENNA MOUNTING �GROUBAR yF+i b-•-.---•-•-•-.-.---•- TYPE C-11 N OR EQUN.) PIPE (TYP) a 4 1.75' FRONT INSULATED SPLIT-COLLAR BUSHING (GARVIN u O . 1.50' ICE BRIDGE POSE P/N GCHK100 WITH GROUND LUG REMOVED) - JUMPER 0 2 OR SIMILAR POST. COAX CABLE TO MAIN o 0 o O (W/N-MALE CONNECTOR) FRONT VIEW COAX s0 DRILL PATTERN COAX CABLE SUPPORT ° O 0 �2 AWG GROUND WIRE CADWELD TO o E O 36.30" POST ONLY IF GROUNDED, OR LUG c o TO CRGB 'P' SECTION OR NEAREST m O o ELEVATION 'P' SUPPLEMENTAL GROUND BAR tr' a NOTES, (COLLAR MOUNT) 0 1. LOCATION OF UNIT MUST HAVE CLEAR VIEW OF SOUTHERN SKY a GROUND PADJ PURCELL AND CANNOT HAVE ANY BLOCKAGES EXCEEDING 25X OF THE JUMPER TO B W/4 1/4-20 FLXI6WS SURFACE AREA OF A HEMISPHERE AROUND THE GPS UNIT. ANTENNA 6-0 BOLTS CABINET 2. ALL GPS UNIT LOCATIONS MUST BE ABLE TO RECEIVE CLEAR c c 1' KO's (TYP) SIGNALS FROM A MINIMUM OF FOUR (4) SATELLITES. VERIFY WITH METAL STRAP m SAME ON LEFT SIDE HANDHELD GPS BEFORE FINAL LOCATION OF GPS UNIT. SUBCONTRACTOR WEIGHT: c TO PROVIDE (TYP) 2' KO's (TYP) ++_- -, 3. CADWELDING SHALL NOT BE PERFORMED ON ROOFTOPS. e pIpLEXER ANTENNA MOUNTING o EMPTY W/BIJWK DOOR � BOlbs SAME ON LEFT SIDE I �� "mac a EMPTY W/ HEAT EXCHANGER = 1201bs 1 HEAT EXCHANGER i� 't v 4. LTE-GPS UNIT SHALL BE LOCATED 10' FROM ALL UNIT. PIPE (TYP) o € EQUIPMENT (VARIES) = 400/Ibs MAX m CABINET TOTAL (MAX) = 6001ba ; �; �$ ` � ;1 LTE—GPS UNIT o �t�E--� g LdS2gS: �+ PIPE & L—BRACKET MOUNT GROUND BAR 1 r¢ s 1. DOOR HINGE MAY BE REVERSED ;i JUMPER TOMAIN COAX Q$ 2. MINIMUM ANCHOR SIZE MUST BE 1/2'0IA. 3. AN ISOLATOR BASE IS REQUIRED WHEN MOUNTING 01 SIDE VIEW 0 0, DIRECTLY ON CONCRETE PAD. +� - t O+' G_ 0 PLAN -L O yC° C 6 n M m O C u o 'o E� o O m W y PURCELL FLXI6WS CABINET SPECIFICATIONS - 11 riaSCALE:N.T.S. AO5 GPS UNIT MOUNTING DETAIL _ilia s SCALE: N.T.S. A05 DIPLEXER MOUNTING DETAIL SCALE: N.T.S. A05 o~ N `Z 0 M, o o€ BECHTEL ASSOCIATES SITE NAME:ORIENT POINT 'A ® aut PROFESSIONAL CORPORATION SITE NUMBER: NYCENY0735 ��Q e GPS UNIT MOUNTING, PURCELL m` A UNIT OF BECHTEL CORPORATION 23300 MAIN ROAD OL t of/ta/ts LTE-ISSUED FOR CONSTRUCTION AS x o 01/04/13 LTE-tssuEo FOR coratRucraN w5 INET de D1PLD(ER MOUNTING DETAILS v 3 r I 5275 WESTVIEW DRIVE ORIENT, NY 11957 No DATE REVISIONS BY sR"M10 WHIM r ° FREDERICK, MD 21703-8386 USA a o SWL'AS Narm CF9CNts EM.AS ppApN M. -415 T3-NYCENY0735-A05 1 U da St 2 ■ 4 04 '"�'ESSIO A CUT POST LENGTH TO SUIT BY i C3 * INSTALL DRIP LOOP ON ANTENNA REMOVING UNCAPPED END ;. DC2 H CABLES AT BOTTOM OF 2 DCB-RM Cl FC12 C2 DC2 RRH TOWER/MONOPOLE. BENDING 12" WIDE ICE BRIDGE n o RADIUS PER MANUFACTURER'S CUT ICE BRIDGE CHANNEL o ` DC2 RRH STANDARDS LENGTH TO SUIT (SEE NOTES) Ell BOND SECTIONS TOGETHER WITH u o` LD1 D2 D3 � a q 6 AWG WIRE. c« FIGURE 1 - TRUNK CABLE TO JUNCTION BOX z EZE KIT MAXIMUM CABLE LENGTHS FOR FIGURE 1 o OTRDER ADDITIONAL TRAPEZE KITS c°g D1 LENGTH (FT) z AS REQUIRED..TO MAINTAIN aT a MAXIMUM CABLE SPAN OF 3'-0" u ; Cl SIZE C2 SIZE 7511001125 150 175 200 250 ) BAWG 191 166 141 116 91 66 16 0 m BAWG 10AWG .. 119 103 88 72 56 41 10 N c n 12AWG 75 65 55 45 36 26 6 Fa yBAWG 145 105 65 25 - - - it ANTENNA CABLES ARRANGEMENT 0 10AWG 10AWG 90 65 40 15 - - - v BY CONTRACTOR 12AWG 57 41 25 10 - - - z N o BAWG w 75 11 - a c 12AWG 10AWG 47 7 •' 12AWG 29 4 - - - - 0 `o CABLE C3 MAY BE EITHER 1OAWG OR 12AWG. 1n -6@ LENGTH D3 IS 16 FEET ALL CASES CONCRETE PIER u_ a RRH F c Cl C2 r E DC6-RM DOME RRH .= RRH 12' m C v r LD1 D2 r $ c FIGURE 2 - TRUNK CABLE TO DC6 (DOME) c C1 DC2 C2 RRH a c 0 u DC6-RM C2 RH MOTE$ o `o_ DC2 RRH 1. WHEN USING COMPONENTS AS SHOWN IN STANDARD DETAILS. MAXIMUM ALLOWABLE SPAN BETWEEN u€ LDt D2 SUPPORTS ON A CONTINUOUS SINGLE SECTION OF BRIDGE CHANNEL SHALL BE 9 FEET FOR 10 FEET BRIDGE CHANNEL .2` FIGURE 3 - DIRECT CABLE TO DC2 2. WHEN USING COMPONENTS FOR SPUCING BRIDGE CHANNEL SECTIONS, THE SPUCE SHOULD BE c MAXIMUM CeAL LENGTHS FOR FIGURES 2 AND 3 PROVIDED AT THE SUPPORT, IF POSSIBLE, OR AT A MAXIMUM OF 2 FEET FROM THE SUPPORT. 3. WHEN USING COMPONENTS, SUPPORT SHOULD BE PROVIDED AS CLOSE AS POSSIBLE TO THE ENDS Q o DI/D2 LENGTH (FT) OF ICE BRIDGES, WITH A MAXIMUM CANTILIVER DISTANCE OF 2 FEET FROM THE SUPPORT TO THE a,.. FREE END OF THE ICE BRIDGE. c t CABLE 8 AWG 10 AWG 12 AWG C1 285 185 104 4. CUT BRIDGE CHANNEL SECTIONS SHALL HAVE RAW EDGES TREATED WITH A MATERIAL TO RESTORE o THESE EDGES TO THE ORIGINAL CHANNEL, OR EQUIVALENT, FINISH. m c M C2 16 16 16 � e 5. ICE BRIDGES MAY BE CONSTRUCTED WITH COMPONENTS FROM OTHER MANUFACTURERS, PROVIDED t THE MANUFACTURER'S INSTALLATION GUIDELINES ARE FOLLOWED. 0 c 6. DEVIATIONS FROM STANDARDS FOR COMPONENT INSTALLATIONS ARE PERMITTED WITH THE RESPECTIVE c MANUFACTURER'S APPROVAL c F 7. DEVIATIONS FROM ICE BRIDGE FOUNDATIONS REQUIRE ENGINEERING APPROVAL m� c oa c o u V � ° LTE CONDUCTOR SIZES y 408 ICE BRIDGE DETAIL _154 c SCALE: N.T.S. A06 SCALE: N.T.S. A06 M C D N p L_ 02 0 Z Nie D M e BECHTEL ASSOCIATES SITE NAME:ORIENT POINT ® at&t PROFESSIONAL CORPORATION SITE NUMBER: NYCENY0735 ��Q} x doe A UNIT OF BECHTEL CORPORATION 23300 MAIN ROAD Off` > 0�/10/» Lrz-ssum►vR corsrRucna+ tis g * LTE C BRIDGER SIZES ORIENT, NY 11957 0 01/04/13 LTE-ISSUED FOR CONS RWnON AS & ICE BRIDGE DETAIL 5275 WESTVIEW DRNE 0 NO OATS REVLSIONS E1Y� FREDERICK, MD 21703-8386 USA ���� aEv ti as SCAM AS NOTED WSOM M AS ommN ar. A n E 415 T3-NYCENY0735-A06 1 �'� 34 3 L Si 22 • 4 I �ESSIO�P�, w� 1 COAXIAL SURGE ARRESTORS ;�a ---1 ---� ---�. --� ---1 ---1 T(TYp FOR 6) COAX TO TOWER i i i i i r o NOTES* u m 1. FURNISHED BY AT&T. ci 2. INSTALLED BY BECHTEL c o DIPLEXER DIPLEXER DIPLEXER DIPLEXER DIPLEXER DIPLEXER 3. FURNISHED BY BECHTEL r NOTES 3, 4 NOTES 3, 4 NOTES 3. 4 NOTES 3, 4 NOTES 3, 4 NOTES 3, 4 4. INSTALLED BY BECHTEL. 0 0 5. FURNISH AND FINAL CONNECTION BY ERICSSON. m 6. LFMC TO BE PROVIDED BY GC. a`0 7. DELETED a 3 8. DELETED ° 9. BREAKERS TO BE TAGGED AND LOCKED OUT. 10. SIAD IS FURNISHED AND INSTALLED BY OTHERS AND INCLUDES POWER CONNECTIONS AND CABLE 1O COAX JUMPERS TO THE NETWORK INTERFACE DEVICE OR AS SCOPED BY MARKET. NOTES: 3, 4 11.LEC TO FURNISH AND INSTALL NETWORK INTERFACE DEVICE. N (TYP FOR 12) 12.COIL EXTRA LENGTH OF FIBER CABLE(S) WITHIN FIBER MANAGEMENT BOX OR TRAY (NOT SHOWN) - INSTALLED IN PURCELL CABINET AS SITE CONDITIONS ALLOW. 13.BECHTEL GC TO MAKE MEASUREMENTS PRIOR TO INSTALLATION FOR APPROPRIATE CABLE LENGTHS. u `o MOUNTED ON 700 RRU AWS RRU 700 RRU AWS RRU 700IRR 14.SINGLE-CONDUCTOR DC POWER CABLES SHALL BE TELCOFLEX° OR KS24194, COPPER, UL LISTED ° WALL OR NOTES NOTES NOTES NOTES NORHH NON-HALOGEN, LOW SMOKE WITH BRAIDED COVER, TYPE TC (1/0 AND LARGER). UNLESS eUNISTRUT RACK 1, 2, 5 1, 2, 5 1, 2, 5 1, 2, 5 1, OTHERWISE NOTED, STRANDING SHALL BE CLASS B (TYPE 111) FOR CABLES SIZES 14, 12 & 10 AWG AND CLASS I (TYPE IV) FOR SIZES 8 AWG AND LARGER. CABLES SHALL BE COLOR CODED oo RED FOR +24V, BLUE FOR -48V AND GRAY FOR 24V AND 43V RETURN CONDUCTORS. MULTI-CONDUCTOR DC POWER CABLES SHALL BE COPPER, CLASS B STRANDING WITH FLAME RETARDANT PVC JACKET, TYPE TC, UL LISTED TOR 90'C DRY/ 7SC WET INSTALLATION. 6 AWG 15.DC SURGE SHELF SHALL BE RAYCAP DC6-48-60-RM. SEE DETAIL 1409A FOR INTERNAL WIRING m (TYP FOR 6) DIAGRAM. ° SI 16.SEE DETAIL 1150J FOR ALARM GABLE REQUIREMENTS. 2/C 12 AWG DC CABLES I m 17. SEE DETAIL 1505A FOR GPS ANTENNA AND SURGE SUPPRESSOR COAXIAL CABLE CONNECTION. NOTES 3, 4, 5, 13 I I a r (TYP FOR 6) S t ROUTED IN 1 1/2- RNC/LFMC CONDUIT OR TRAY v PURCELL (FLXI6WS) °o I LTE OUTDOOR CABINET - t 2 COUNT, SINGLE MODE FIBER NOTES: 1, 2 FIBER CABLE FIBER FIBER GPS ANTENNA & 0 NOTES 3, 4, 5 SURGE SUPPRESSOR t o (TYP FOR 6) NOTE: 3, 4, 12 GPS D7 c ROUTED IN LFNC FLEXIBLEF RECENER UNIT NOTES: 3, 4, 17 DIGITAL NOTES: 1, 2, 5 m ° CONDUIT OR TRAY CABLE o� o r-2 AWG °% (1) LTE DUL 20 ---�2 AWG-- _ ' 6 AWG 700 MHz & AWS PDU 1 = $o DC SURGE SHELF a" NOTES: 3, 4, 15 2 AWG DC PDU -� 0 0 (1) 15A FUSE - €L (12) 1/C 10 AWG (2) 1/C 6 AWG IN ALARM CABLE `c m NOTES: 3. 4 1' LFMC CONDUIT NOTES: 1, 2, 5 a t NOTES: 3, 4, 6 DUL POWER GABLE -. NOTES: 1, 2, 5 DC BREAKER PANEL v= (1) 50A & (6) 25A c o BREAKERS 66 BLOCK 1' LFMC CONDUIT °u F - - NOTES 3, 4, 9 _-_,� (w/PULL STRING) - SYSTEM DIAGRAM, TOWER SITE 0 ;1I NOTES: 3, 4, 6 WITH OUTDOOR BASE BAND IAD �'a �- ------------ NOTESS 10 AND RRUs AT GRADE U j O o BY OTHERS I NOTES: 3, 4, 16 DETAIL NETWORK INTERFACE 40 IE o' DEVICE NOTE 11 E01 SCALE:N.T.S. ri v (VARIES BY MARKET) n CCj l-2 AWG 0� OUTDOOR POWER CABINET Z 0 g BECHTEL ASSOCIATES SITE NAME:ORIENT POINT �G 96 at&t PROFESSIONAL CORPORATION SITE NUMBER: NYCENY0735 �}p m �� LOL 1 Ol/10/13 LTE-ISSUED FOR WNSiRUCfiOH AS • SYSTEM DIAGRAM 9 °` ® A UNIT OF BECHTEL CORPORATION 23300 MAIN ROAD tt x O 01/04/13 LTE-ISSUm FOR CONSIRUCfiON AS a 3 i 5275 WES'MEW DRIVE ORIENT, NY 11957 `o° FREDERICK, MD 21703-8386 USA Ro DATE REVISIONS Bf nrur�No �+ ' `n a AS Nmm ommim ee AS --.. 415 T3-NYCENY0735-E01 1 O "S 4 3 9- `x0.• NZE 22 .34 AN51 W pRO�ESSIONP'y� A r-----� I I 0 0 m.y I I 1900 OR AWS 700 I I SECTOR A SECTOR A a v (2) 1/C 1 AWG I I I I u POWER CABLES FLI L c SEE NOTE 13 0 ° ALCATEL-LUCENT _ _(1YP EACH CABLE) L__ __J ) Ir 2/C POWER CABLES z m cbt m no 9412CABINETW2 + NOTE12 1 + I + I + I + 1 + 1 + - - o o. / 48V lX: _ InyI tntn In�t NOTE 11) JUNCTION BOX (6 TYP) (NOTE 6) Qug i�4u nb$ 33 33 33 `0 9926 (BBU) INPUT A ARM n n n n n a a << <a (NOTE 14 + - ❑ ❑ + -❑ c U I I 11 1 1 I I I I I I SEE NOTE 13 (TYP) ) c CABLE <a m m o Lt << m m u u A-AWS+ a i� NC -+ -+ -t -+ -+ -+ A-AWS- + FIBER & POWER + am eAM 700 KS C DC SURGE SHELF RAYCAP DC6-RM A-700+ + DISTRIBUTION + I I c `° 1 (NOTES: 2. 9) �, A-700- _ 48V SURGE PROTECTION _ ALCATEL-LUCENT 2/C 12 AWG (MIN.) RAYCAP DC2 6 AWG 8 AWG 9926 (BBU) t -+ -+ -+ -t -+ -+ 5 AWG = - 48V DCHB _ POWER CABLES (6 TYP) (NOTES 7, 8) NC ALARM �w 70OMHz INPUT (NOTE 6) C TO GROUND CABLE TO GROUND c n ALARM kO EQUIP. CABINET °N 0 GND BAR 1900 OR AWS 700 a FIBER PORTS JACKS GND SECTOR B SECTOR B v" 1 2 3.4 5 6 T1 RJ45 (12) 1/C 12 AWG ��'�-6 AWG ❑❑❑❑ 3,E3 JACKS POWER CABLES = oc4 TO F n ALARM GROUND o o c eAM 1900 DR AWS JACKS _ S d o a ALCATEL-LUCENT r8 -48V + - ❑ ❑ + -❑ 0 9926 (BBU) '� DC S 0 1800 OR AWS INPUT l , B-AWS+ � v E ALARM B-AWS- + FIBER & POWER + m $ FIBER PORTS JACKS GND OV 8-700+ - DISTRIBUTION 1 2 3 4 5 6 Ti RJ45 +24V INPUT 24V TO -48V CONVERTER _ 49V SURGE PROTECTION e p e +24V-INPUT 8-700- + WITH + � , ❑❑❑❑❑❑ JACKS FEED A FEED B (NOTE 3). WITH RAYCAP DC2 $ c INTEGRAL -48V BREAKER PANEL (NOTES 7 8) NC 6 AWG = 6 AWG , (NOTE 3) FACTORY (NOTE 2) C TO GROUND ALARM TO GROUND e o WIRING ALARM CABLE TERMINAL 1 1900 OR AWS 700 NOTE 4 NOTE 3 c SUPPORT , +GND O/P ( ) ( ), OV BLOCK SECTOR C SECTOR C y 00 STAND (4) 1/C 4/0 AWG - GND I/P ' -6 AWG co 2 AWG POWER CABLES = v 8 € TO TO ! t° 2 AWG i 6 AWG ALARM CABLE GROUND o m° GROUND �j ol (NOTE 10) �_ �_ (NOTE 5) TO 66 BLOCK y S - - IS SHEET) TO EQUIP. CABINET z m z ca m Z$ GND BAR NOTES 0 1. LABEL THE DC POWER CABLES AT BOTH ENDS OF EVERY WIRE AND IN ANY PULL BOX IF USED. LABEL SHALL BE C-AWS+ + + ' a" INSTALL (2) (N, DURABLE. SELF ADHESIVE. WRAPPED LONGITUDINALLY ALONG THE CABLE AND STATE THE SECTOR, FREQUENCY BAND AND C-AWS- _ FIBER do POWER _ L 25M BR POLARITY: I.E. 'A-AWS+% C-700+ DISTRIBUTION Q' 2. INSTALL IN AUXILIARY EQUIPMENT CABINET _ t WITH + , 0 e 24V 3. CABLE TERMINALS FOR +24V INPUT FEED A, FEED B AND REFERENCE GROUND SHALL BE 2-HOLE 3/8' ON 1' C-700 - 48V SURGE PROTECTION - € CENTER. RAYCAP DC2 — 6 AWG — 6 AWG B a (+) 4. INSTALL CABLE TERMINALS FOR FEED A AND FEED B RETURN BACK-TO-BACK ON OPPOSITE SIDES OF PAD USING (NOTES 7, 8) NC - .e 1-HOLE 3/8'TERMINALS. C TO GROUND CABLE TO GROUND °. 5. CABLE TERMINALS FOR CHASSIS GROUND SHALL BE 2-HOLE. 1/4- ON 5/8- CENTER. o Oy 8. SEE DETAIL 1408 FOR CABLE SIZES AND MAXIMUM LENGTH. - 7. SEE DETAIL 1411 FOR INTERNAL WIRING DIAGRAM. CABLE GROUND WIRES NOT SHOWN FOR CLARITY. ' o 2 S. FIBER AND POWER DISTRIBUTION BOX IS NU REQUIRED WHEN THE DC CABLE BETWEEN THE DC POWER CABINET AND �-6 AWC RRH IS LESS THAN 49 FEET. e 9. SEE DETAIL 1409A FOR INTERNAL WIRING DIAGRAM. o; PART OF DC POWER PLANT 10.CONVERTER REFERENCE GROUND IS NOT REQUIRED WHEN CONVERTER AND 24V DC POWER,PLANT ARE ON THE SAME TO c RACK OR ENCLOSURE. GROUND 0 ' = 11. THE BARE WIRE OF EACH MULTI-CONDUCTOR CABLE AND DRAIN WIRE WHEN A SHIELDED CABLE IS USED. SHALL BE o CRGB CONNECTED TO THE EQUIPMENT CABINET GROUND BAR. WIRING DIAGRAM, OUTDOOR 0 0 12.SEE ALARM BLOCK ASSIGNMENT DETAIL FOR ALARM CABLE CONNECTIONS. - 0 13. WHEN A 1900 RRH IS USED INSTEAD OF AN AWS RRH CABLE LABELS SHOULD REFLECT CORRECT FREQUENCY BAND. BASE BAND AND RRHs ON GROUND, °M 14. PROVIDE A JUNCTION BOX, AS SCOPEO BY MARKET. TO COIL EXCESS DC POWER AND OPTICAL FIBER CABLES. (FIBER DC/DC CONVERTER CABLES NOT SHOWN FOR CLARITY) N 0 41 DETAIL EO T.S. e _ °z e 0 e t €g SITE NAME:ORIENT POINT �G -� ® at&t a a o BECHTEL ASSOCIATES _ PROFESSIONAL CORPORATION SITE NUMBER: NYCENY0735 ���� rfi" RRH WIRING DIAGRAM o ® A UNIT OF BECHTEL CORPORATION 23300 MAIN ROAD 1 Ot/ta/ts uE-ISSUED MR AS .c•c a ORIENT, NY 11957 O 01/a/13 LTE-ISSUm FOR WNSMUMM As m , o ;t 5275 WESTVIEW DRIVE o+ N0 DATE REVLsiONs er oaArNo Nuwan Im c t FREDERICK, MO 21703-8386 USA ti a3 srxr As NOIFD ocsnum W.AS awm er: i�15 9-415 T3-NYCENY0735-E02 1 _ Q �r Q 3 = / , SZE 22 ■347 ANS O A -,.. 9 ROFESS014 22 ELECTRICAL INSTALLATION NOTES (AS APPLICABLE) SYMBOLS t= S G SOLID GROUND BUS BAR a. m� 1. WIRING, RACEWAY, AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS 23. CABINETS, BOXES, AND WIREWAYS SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE OF THE NEC AND TELCOROIA, WITH NEMA, UL, ANSI/IEEE, AND NEC. S N SOLID NEUTRAL BUS BAR oti 3 a 2. SUBCONTRACTOR SHALL MODIFY EXISTING CABLE TRAY SYSTEM AS REQUIRED TO SUPPORT RF AND 24. CABINETS, BOXES, AND WIREWAYS TO MATCH THE EXISTING INSTALLATION WHERE POSSIBLE. F1 (1- SUPPLEMENTAL GROUND CONDUCTOR �� TRANSPORT CABLING TO THE NEW BTS EQUIPMENT. SUBCONTRACTOR SHALL SUBMIT MODIFICATIONS TO °T° 2-POLE THERMAL-MAGNETIC C c CONTRACTOR FOR APPROVAL. 25. WIREWAYS SHALL BE EPDXY-COATED (GRAY) AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN CIRCUIT BREAKER ° DOWNWARD; SHALL BE PANDUIT TYPE E (OR EQUAL); AND RATED NEMA 1 (OR BETTER) INDOORS, OR NEMA o ° c c 3. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY 3R (OR BETTER) OUTDOORS. ° THE NEC AND TELCORDIA. SINGLE-POLE THERMAL-MAGNETIC u ` 26. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES, AND PULL BOXES SHALL BE GALVANIZED OR ° ° CIRCUIT BREAKER m° 4. CABLES SHALL NOT BE ROUTED THROUGH LADDER-STYLE CABLE TRAY RUNGS. c EPDXY-COATED SHEEP STEEL, SHALL MEET OR EXCEED UL 50, AND RATED NEMA 1 (OR BETTER) INDOORS, 9 CHEMICAL GROUND ROD °c o 5. EACH END OF EVERY POWER, GROUNDING, AND Tt CONDUCTOR AND CABLE SHALL BE LABELED WITH COLOR- OR NEMA 3R (OR BETTER) OUTDOORS r CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1/2 INCH PLASTIC ELECTRICAL TAPE WITH UV (& GROUND ROD o PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC & OSHA, AND MATCH 27• METAL RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY-COATED, OR NON- °¢� ) CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1; AND RATED NEMA 1 (OR BETTER) DISCONNECT SWITCH EXISTING INSTALLATION REQUIREMENTS. INDOORS, OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. ,p c o ; 6. POWER PHASE CONDUCTORS (I.E., HOTS) SHALL BE LABELED WITH COLOR-CODED INSULATION OR 28. NONMETALLIC RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2; AND METER a ELECTRICAL TAPE (3M BRAND, X INCH PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). PHASE RATED NEMA 1 (OR BETTER) INDOORS, OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. to CONDUCTOR COLOR CODES SHALL CONFORM WITH THE NEC & OSHA AND MATCH EXISTING INSTALLATION Ill CADWELD TYPE CONNECTION n REQUIREMENTS. 29. THE SUBCONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CONTRACTOR °'n BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. COMPRESSION TYPE CONNECTION c a 7. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH ENGRAVED LAMACOID PLASTIC LABELS. u ALL EQUIPMENT SHALL BE LABELED WITH THEIR VOLTAGE RATING, PHASE CONFIGURATION, WIRE ---- GROUNDING WIRE v ° 30. THE SUBCONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND ° CONFIGURATION, POWER OR AMPACITY RATING, AND BRANCH CIRCUIT ID NUMBERS (I.E., PANELBOARD AND � DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD CIRCUIT ID-S). AGAINST LIFE AND PROPERTY. 2° B. PANELBOARDS (ID NUMBERS) AND INTERNAL CIRCUIT BREAKERS (CIRCUIT ID NUMBERS) SHALL BE ABBREVIATIONS `o c CLEARLY LABELED WITH ENGRAVED LAMACOID PLASTIC LABELS. 115 DETAIL AGL ABOVE GRADE LEVEL g e 9. ALL TIE WRAPS WHERE PERMITTED SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP E03 SCALE: N.T.S. AWG AMERICAN WIRE GAUGE c c EDGES. USE LOW PROFILES TIE WRAPS. BCW BARE COPPER WIRE c 10. POWER, CONTROL, AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE CONDUCTOR BTS BASE TRANSCEIVER STATION E (12 AWG OR LARGER), 600 V. OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED - FOR 90 'C (WET AND DRY) OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED, TRANSIENT VOLTAGE SURGE SUPPRESSION "SS) (E) EXISTING 3 UNLESS OTHERWISE SPECIFIED. ° m EG EQUIPMENT GROUND a 11. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE CONDUCTOR (6 AWG OR 5 LARGER), 600 V. OIL RESISTANT THHN OR THWN-2 GREEN INSULATION, CLASS B STRANDED COPPER CABLE 1• RF DEVICES SHALL BE INSTALLED IN ALL NEW ANTENNA & NEW COAXIAL INSTALLATION OR EGR EXTERNAL GROUND RING REPLACEMENTS. MENTS. o v RATED FOR 90 'C (WET AND DRY) OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM EMT ELECTRICAL METALLIC TUBING c c USED, UNLESS OTHERWISE SPECIFIED. 2. SEE DETAIL 116 AND 124 FOR ADDITIONAL RF COAXIAL TVSS REQUIREMENTS. GEC GROUNDING ELECTRODE CONNECTION mw o 12. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED OUTDOORS, OR BELOW GRADE, SHALL BE SINGLE 3. AC TVSS DEVICES FOR AC POWER SHALL BE INSTALLED FOR ALL NEW AC PANEL INSTALLATION OR GEN GENERATOR CONDUCTOR 2 AWG SOLID TINNED COPPER CABLE, UNLESS OTHERWISE SPECIFIED. REPLACEMENTS `o GRC GALVANIZED RIGID CONDUIT t c 13. POWER WIRING, NOT IN TUBING OR CONDUIT, SHALL BE MULTI-CONDUCTOR, TYPE TC CABLE (12 AWG OR 4. THE AC TVSS SHALL BE COMMON MODE TYPE, MINIMUM RATED 120kA SURGE CURRENT, AND HAVE IGR INTERNAL GROUND RING (HALO) g € LARGER), 600 V, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED FOR 90 'C (WET MONITORING LIGHTS WITH FORM C ALARM CONTACTS. THE AC TVSS SHALL BE INNOVATIVE TECHNOLOGIES m,2 AND DRY) OPERATION; WITH OUTER JACKET; LISTED OR LABELED FOR THE LOCATION USED, UNLESS ZE PTX120 OR OWNER APPROVED EQUAL THE TVSS SHALL BE CONNECTED TO THE AC SYSTEM THROUGH A IMC INTERMEDIATE METALLIC CONDUIT $ c OTHERWISE SPECIFIED. CIRCUIT BREAKER IN THE AC PANELBOARD AND SHALL BE MOUNTED INTEGRAL WITH THE PANELBOARD OR ° DIRECTLY ADJACENT. MGB MASTER GROUND BAR o w 14. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP-STYLE, COMPRESSION WIRE LUGS AND WIRENUTS MIN MINIMUM °c n BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRENUTS SHALL BE RATED FOR OPERATION AT NO LESS THAN 5. Tl TVSS DEVICES SHALL BE INSTALLED IN ALL NEW Tl INSTALLATIONS (TYPE AS APPROVED BY AT&T M) a 757C (90'C IF AVAILABLE). N.T.S. NOT TO SCALE co 6. THE SUBCONTRACTOR SHALL INSPECT THE EXISTING TELCO SYSTEM FOR TVSS PRESENCE AND REPORT n�-c r 15. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH FINDINGS TO CONTRACTOR. PVC RIGID (SCH.40) POLYVINYL ° 4 NEMA, UL, ANSI/IEEE, AND NEC. CHLORIDE CONDUIT c 7. SURGE SUPPRESSION AND PROTECTION DEVICES SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE ter° 15. NEW RACEWAY OR CABLE TRAY WILL MATCH THE EXISTING INSTALLATION WHERE POSSIBLE. NATIONAL ELECTRICAL CODE (NEC) ARTICLE 250. 250, 285, AND CHAPTER 8, AS APPLICABLE. RBS RADIO BASE STATION C m REF REFERENCE 17. ELECTRICAL METALLIC TUBING (EMT) OR RIGID NONMETALLIC CONDUIT (I.E., RIGID PVC SCHEDULE 40, OR °L RIGID PVC SCHEDULE 80 FOR LOCATIONS SUBJECT TO PHYSICAL DAMAGE) SHALL BE USED FOR EXPOSED 117 DETAIL REQ REQUIRED m INDOOR LOCATIONS. E03 SCALE: N.T.S. RF RADIO FREQUENCY c O RGS RIGID GALVANIZED STEEL c 0 18. ELECTRICAL METALLIC TUBING (EMT), ELECTRICAL NONMETALLIC TUBING (ENT), OR RIGID NONMETALLIC ° CONDUIT (RIGID PVC, SCHEDULE 40) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. TRANSPORT T1 LINES RWY RACEWAY c a SIAD SMART INTEGRATED ACCESS �■ 19. GALVANIZED STEEL INTERMEDIATE METALLIC CONDUIT (IMC) SHALL BE USED FOR OUTDOOR LOCATIONS 1. ALL RACEWAY SHALL COMPLY WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE (NEC, NFPA DEVICE ° c ABOVE GRADE. ° > 70), CHAPTER B. TBD TO BE DETERMINED E.8 $ 20. RIGID NONMETALLIC CONDUIT (I.E.. RIGID PVC SCHEDULE 40 OR RIGID PVC SCHEDULE 80) SHALL BE USED 2. ALL SPECIFIED MATERIAL FOR EACH LOCATION (E.G.. OUTDOORS, INDOORS-OCCUPIED, UNDERGROUND; DIRECT BURIED, IN AREAS OF OCCASIONAL LIGHT VEHICLE TRAFFIC OR ENCASED IN REINFORCED INDOORS-UNOCCUPIED, PLENUMS, RISER SHAFTS, ETC.) SHALL BE APPROVED, LISTED, OR LABELED AS TBR TO BE RESOLVED °:5 CONCRETE IN AREAS OF HEAVY VEHICLE TRAFFIC. REQUIRED BY THE NEC. TYP TYPICAL FE 3. METALLIC CONDUIT OR TUBING FOR 71 LINES SHALL BE BONDED TO GROUND AT BOTH ENDS. rn VIF VERIFY IN FIELD c 4. FOR NOK!A GSM BTS CABINET ONLY - THE Tl CABLE SHALL BE IDENTIFIED AT BOTH ENDS WITH A Ni c 21. LIQUID-TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, COMPUTER-PRINTED SELF-LAMINATING POLYESTER WIRE MARKERS (BRADY CORP. OR EQUAL). USE THE WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. N T, 'FROM" LOCATION FOLLOWING TYPICAL ID NAME AT THE NIU AND AT THE NOKIA BTS: c« 22. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION-TYPE AND APPROVED FOR THE a w LOCATION USED. SETSCREW FITTINGS ARE NOT ACCEPTABLE. AT&T UMTS VIATIONS&SYMBOLS o z° LEC CCT# EL c a2 0 ° m� SITE NAME:ORIENT POINT ® at&t C €a BECHTEL ASSOCIATES PROFESSIONAL CORPORATION SITE NUMBER: NYCENY0735 �}9 9 ® A UNIT OF BECHTEL CORPORATION 23300 MAIN ROAD `v[ i o1/04/I3 LTE-ISSUED FOR CM6iRUCIION AS Ro ELECTRICAL&T NOTES.O ABBREV. rn 3 t i 5275 WESTVIEW DRIVE ORIENT, NY 11957 0 o1/a/1a LTE-ISSUED FOR CONSERI1Cf10N AS rn NO DATE REVISIONS BY B� DRAWM NUUM R� •- FREDERICK, MD 21703-8386 USA Norm as srxr AS OMMM B°AS - N 1 .:� - SRE 22 r J4 AN51 R�FESSIU►4P� GROUNDING NOTES (AS APPLICABLE) L:x 6 AWG STRANDED Cu m B WIRE WITH GREEN, 600V, 0.0 SUBCONTRACTOR SHALL REVIEW AND INSPECT THE EXISTING FACILITY GROUNDING SYSTEM AND LIGHTNING m; 1. THE mNEWTON INSTRUMENT COMPANY, INC. THWN INSULATION PROTECTION SYSTEM (AS DESIGNED AND INSTALLED) FOR STRICT COMPLIANCE WITH THE NEC (AS ADOPTED BY BUTNER, N.C. OR APPROVED EQUAL F THE AHJ), THE SITE (UL, LPI, OR NFPA) LIGHTING PROTECTION CODE, AND GENERAL COMPLIANCE (SUNLIGHT RESISTANT) WITH TELCORDIA AND TIA GROUNDING STANDARDS. THE SUBCONTRACTOR SHALL REPORT ANY VIOLATIONS OR NO. REQ. PART NO. DESCRIPTION OR BLACK MARKED i ADVERSE FINDINGS TO THE CONTRACTOR FOR RESOLUTION. AS REQUIRED BY NEC O 1 1/4"x4"x30" SOLID GND. BAR c GROUND BAR ON 2. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION, AND AC O 2 A-6056 WALL MTG. BRKT. WALL, FLOOR o POWER GES'S) SHALL BE BONDED TOGETHER, AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING OR ON ANTENNA s Q CONDUCTORS IN ACCORDANCE WITH THE NEC. O3 2 3061-4 INSULATORS TOWER m o c1 03. THE SUBCONTRACTOR SHALL PERFORM IEEE FALL-OF-POTENTIAL RESISTANCE TO EARTH TESTING (PER IEEE ® 4 3012-1 5/g"-11x1" H.H.C.S. 10 1100 AND 81) FOR NEW GROUND ELECTRODE SYSTEMS. THE SUBCONTRACTOR SHALL FURNISH AND INSTALL OS 4 3015-8 5/8 LOCKWASHER '.-a SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. TESTS O O O Tt SHALL BE PERFORMED IN ACCORDANCE WITH 24782-000-3PS—EGOO-0001, DESIGN & TESTING OF FACILITY OOO O O 0 o m GROUNDING FOR CELL SITES. DOUBLE CRIMP O O Q O Q O QO O O > CONNECTION c 4. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED INTERIOR 2 3 o i COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED GROUND RING 0 € AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. a ANGLE SHOWN TO EXOTHERMIC WELD ILLUSTRATE WELD an 5. EACH BTS CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN 1 2 0 5 4 (WELDING ROHIBITED AT THE LOWEST o N INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, 6 AWG STRANDED COPPER OR LARGER FOR INDOOR I ON ROOFTOPS) POINT ON THE BAR c BTS; 2 AWG STRANDED COPPER FOR OUTDOOR BTS. OA o ® ° 13„ 2 AWG SOLID BARE TINNED m ° 6. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. COPPER GROUND CONDUCTOR. 0 4" EXOTHERMIC EXOTHERMIC WELD TO BURIED 20 7. APPROVED ANTIOXIDANT COATINGS (I.E., CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION 13' 1 WELD GROUND RING AND GROUND BAR m w AND BOLTED GROUND CONNECTIONS. `o a B. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED WITH STAINLESS STEEL m ? HARDWARE TO THE BRIDGE AND THE TOWER GROUND BAR. EACH GROUND CONDUCTOR TERMINATING ON ANY GROUND BAR SHALL HAVE INSTALLATION OF GROUND WIRE o n 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING AN IDENTIFICATION TAG ATTACHED AT EACH END THAT WILL IDENTIFY ITS 11g TO COAX CABLE GROUND BAR DETAIL m c CONNECTIONS. ORIGIN AND DESTINATION s o E04 SCALE: N.T.S. 10. MISCELLANEOUS ELECTRICAL AND NON—ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED SECTION 'P" — SURGE PROTECTORS TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. CABLE ENTRY PORTS (HATCH PLATES) (2 AWG) TO TOWER MOUNTED TO TRANSMIT 11. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING GENERATOR FRAMEWORK (IF AVAILABLE) (2 AWG) AMPLIFIER UNITS ANTENNA « c FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH 6 AWG COPPER WIRE UL APPROVED GROUNDING TELCO GROUND BAR (2 AWG) (TMA) (WHEN TYPE CONDUIT CLAMPS. REQUIRED) AND COMMERCIAL POWER COMMON NEUTRAL/GROUND BOND (2 AWG) RECEIVE ANTENNA c c 12. GROUND CONDUCTORS USED IN THE FACILITY GROUND AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE +24V POWER SUPPLY RETURN BAR (2 AWG) 016 ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC -48V POWER SUPPLY RETURN BAR (2 AWG) o WEATHERPROOFING u KIT (TYR CONDUITS, METAL SUPPORT CUPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE RECTIFIER FRAMES. TY t HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALUC MATERIAL SUCH AS COAX SUPPRESSION KIT ) r o PVC PLASTIC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (E.G., NON-METALUC RX7/RX2 RX1/RX2 two CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE SECTION "A" - SURGE ABSORBERS m € METAL CONDUIT. ANTENINA CABLE m o INTERIOR GROUND RING (2 AWG) 13. ALL TOWER GROUNDING SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF ANSI/TIA 222. FOR TOWERS EXTERNAL EARTH GROUND FIELD (BURIED GROUND RING) (2 AWG) I KIT ( ') T BEING BUILT TO REV G OF THE STANDARD, THE WIRE SIZE OF THE BURIED GROUND RING AND CONNECTIONS METALLIC COLD WATER PIPE (IF AVAILABLE) (2 AWG) JUMPER CABLES STANDARD GROUND m BETWEEN THE TOWER AND THE BURIED GROUND RING SHALL BE CHANGED FROM 2 AWG TO 2/0 AWG. IN BUILDING STEEL (IF AVAILABLE) (2 AWG) I I I KIT (1YP.) ADDITION, THE MINIMUM LENGTH OF THE GROUND RODS SHALL BE INCREASED FROM 8 FEET TO 10 FEET. (SEE NOTE) I SECTION "I" - ISOLATED GROUND ZONE � o ALL COMMUNICATIONS .2 OLATED GR UND BAR - IGBE(Z AWG) Gj CONNECTOR WEATHERPROOFING € DETAIL NOTES: KIT (TYP.) o t 1. EXOTHERMICALLY WELD 2 AWG BARE TINNED SOLID COPPER CONDUCTOR TO #6 AWG STRANDED Cu GROUND BAR_ ROUTE CONDUCTOR TO BURIED GROUND RING AND PROVIDE FROM TMA WIRE WITH GREEN. m PARALLEL EXOTHERMIC WELD. (WHEN REQUIRED) 60OV, THWN INSULATION s� (SUNLIGHT RESISTANT) o 2. USE PERMANENT MARKER TO DRAW THE LINES BETWEEN EACH o CIGBE (GROUND BAR), ®� SECTION AND LABEL EACH SECTION ('P", "A", 'I") WITH 1' HIGH LETTERS. REFER TO DETAIL c� c a c NOTE: BELOW S TO NEAR/ BELOW ANTENNA °u 4 1. DO NOT INSTALL CABLE GROUND SEE NOTE 2 E S KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE TO(RGB) REFERENCE GROUND BAR — DETAIL 2. EXISTING CIGBEDOWN BE U EDE WIRE WITH GREEN, IN AWG Cu STRANDED �« W c CONVENIENTLY LOCATED. 60OV, THWN INSULATION (SUNLIGHT RESISTANT) ri v BONDED TO STRUCTURE N 11 y MASTER/EQUIPMENT GROUND BAR DETAIL GROUND OBAR. o 1 13 DETAIL E04 SCALE: N.T.S. CONNECTIO o Z E04 SCALE: N.T.S. E04 SCALE:GROUN ! DT M, JND BAR c c �/ U €� SITE NAME: ORIENT POINT 'fJ ® 8t&t a o BECHTEL ASSOCIATES PROFESSIONAL CORPORATION SITE NUMBER: NYCENY0735 �}�} 9 0 0 ` ` 1 01/lo/1J LTf-ISSUED FOR COtStRUCiION AS *. GROUNDING NOTES do DETAILS A UNIT OF BECHTEL CORPORATION 23300 MAIN ROAD 0 01/W/13 LTE-ISSUED FOR CONSMUCnON As .21 3L "60H 5275 WESTVIEW DRIVE ORIENT, NY 11957 No DATE REVISONS Br ®+ DRUMNUTAMR FREDERICK, MD 21703-8386 USA SCALE'AS� �m�AS DRAWN Li —415 T3—NYCENY0735—E04 1 SIZE 22 • 34 ANSI 0 RDF�ssio'14 a ISNb' VT x ZZ JZIS l Sd 18 NMbRO s �19 3NOI 030N s3 lbJoS l01-S�LOJ�N3OJlN-�1 lip-9�LSZ N F O D. O�� bSn 9828-20LLZ dW `� 0 �3a32�3 0 A38 a38vm ONIMd210 08ym 8of ' ,dd MHO AB SNOISIAMJ MV0 S30T 3ANG M31/-LS3M SLZS 3 � OH so Sd NOInmiSN00 2l03 43nssi-31l C OVO/W o L96 L l M 1NRJO * � � 133HS 31111 *1 08 so sy NoiionHISN00 HOJ 03nssl-31-1 WOL/10 t ab'0?J Nlb'W 0OC2Z N011b�lOd�JOO 331H038 30 11Nn b' �� 06 �, y SELOAN33AN :m38 W n N 311S NOIJ VH0dH00 -lVN01SS330Ud c� °° w a 'i' y' 1NI0d 1N31b10 :3WbN 311S S3JLVIOOSSd 131HO38CD cn, n 0 0 lldb NOI1baNn0-j GNb ONimin8 ONIISIX3 8H1 Ol SNOIlb01-dI4oW ° 0 4.t ON agdi1�Id"I:Wan03 !MNIO0 NQlllaab 3H1 �Od a3lbn-lbA3 NI38 SdH abd 1NIlNdin03 ONIISIX3 003,t o mz-1 IN;.40 �MOOR,� , cl���l`��`ldl L990- LLS ( LOZ) �31H038 Wl�lbyi abZb' �J33NION3 del '� o 02LO- L LS ( L OZ) �31H038 ab00 G JbH014 IVOIU1O313 T Nvion �:�NO0`Ift ?J 3I N I�N 3 1N3W31V�.S ivanionuis a N N�I1TnSNI SOLO- LLS ( LOZ) �31H038 =VZN00 NOSJ.bf' NOIlon2J1SN00 30NVI�dNOO dS NOI1mJISN00 2MNION3 del = a 31U3NO0 Ev`oj1 i x Ol S'l N 3�`dOS �J38WnN 10b1N00 J.NbdWOO 3WdNl C�32JInwai Oml,No1I VONi1Cad rL r)r �rJ�O110� �01 t:: CD:a}n0 (0,00 :Xq paMalnad cut�ni wd v O:.I. l'Qtl zoo�I�� l lVJL3 C] IV 1N�WldbdACl 0t�i,l�i(18 �jiJ_6N ` ��e� I .+ c� l-d I - - c lIW8f1S3d ONb S1N3WW00 3�lOS3d 3Sd3�d — 031d300`d lON ❑ 'Z o 3 � _..�. _ �.. . . SD 0 SlOdlNO3 l03rodd - / c:LUs IWO , l f s c 033002ld )MN NOI10mISN00 `S1N3WW00 ON 2JO 2JONIW HlIM — 031d333V L L k+ + t, F e,.. re, �+�� �� �".i�' 4 1� � s 'ON S(11d1S � �, N?J3�OO TYHS 1NIWI?JIn032J 01d103dS .3H1 `1N3W3?JIn03?J OId103dS b GNb 1S �0 1NIW3?JInOI�I �Vd3N39 b N3�M1I8 101�dN00 SI 3?13H1 3�J3HM 'Nd3A0O �3bHS 1N3W3?JIn0I2J o�yHo� 15 o�yNo Sf11b�1S M31n3d 1N3WflO0a -� IALOI1 LS3?1 1SOW 3H1 `SiNIW3?JIn03?1 �IIH10 K `N011omJ1SN00 d0 SGOHEVW `lbl?J31bW ° 0 ONIG2IVO3Rl Sa2JbaNb1S aNb S3000 a31S1-1 d0 SNOI103S N33M138 S101-IdN00 ).NV Ki S *< N011031O2Jd �b1N3WNOdIAN3 `W003�31 - SW3ISJ.S ?J3MOd 00 - W00=1 d0i ' L L2' Li ISNb � ° Cn ° S1N3w3?Jml0 l N011b-l�b1SNl -Ib�J3NIO `SLZ L-2JO bIG2J00�31 o NOIS�13A iS31b-I - 3003 J.13dbS 0121103I3 �VNOIlbN `Zo 3331 �, L S11�d13a '8 S310N�JNIaNf10aJ tiO3- SELOAN30AN o z L S1O8 WAS '8 AM188t/ S310N SSAl 1dO1a10313 E03- SELOAN30AN 1NIwdIn03 0 L wvu!Dvla JNlHlAA HUH Z03- SELOAN33AN o 01NO�110 Ia ITI do ONNnods QNb ONI2JIMOd 2JOd 30110b?Jd a3aN3HVNOOI J (666 L) 00 L L 1331 0 � w31s�s `� L 1AWHOV10 W31SAS L03- SELOAN30AN C aNnO?JO b d0 S INIl0(d iobd�InS H12Jb3 GNb 30Nba3dWl aNnO?JO JWALSIS3d Hl?JbI ONIdnSb3W 2JOd Ions ' Le (I331) S�IIINIONI S01NO?J103�3 aNb �VOI�J103�3 ?JOd I1niliSNl L 11t/13a na1E18 3OI q S3ZIS uoio laNOO 311 9OV- SELOAN33ANtr o alas s SlIV13CI DNIINnow H3X31d1a CD ? sN011b31Nnwwoo3-lll L 1913NIEW3113ound `JNI1Nf10W llNn SdJ SOV- SCLOAN30AN �% ° �JOd S1NIHI2JCOI?J ONIaN08 aNb ONIONn02JO ONimin8 3b1o�13WW0o `L09 bll o co 'l , -,ate�,�,, �.1 �►��,/� S11V13a 1N3 W3 JVNVUU H38Id V XO8 NOIld33X3 90a 3 3 'S32J(1110n2J1S ON112JOddnS bNN31N`d aNb �J3M01 `dNN31N`d �331S �IOd `ONI1Nf10W (Hidld) CIV3H 01CIV l 310W3H VOV- SELOAN30AN SadbaNblS 7b�Jn10nd1S (966 L) d-ZZZ (N011Vl3OSSb /?J1snaN1 SNOIlb01Nnmlgo3�31) bll/ISNb - S11V13a 19 N011Vn313 310d9Vl=l EOV- 9ELOAN30AN 'NGI1Ja3 H1N331?JIHl �� z � L S310N � ���brld 1N3Wd1f103 ZOb�- SELOAN30AN N0110n?J1SN00 �331S dQ �bnNb'W (3slb) N0110n2J1SN0o �3I1S d0 31n111SN1 Nb01?JIWb CIO� �� L S310N 1b��13N3J 'S N�d1d �dNN31N�d `N�d1d 311S LO�d- SELOAN30AN �' ° ° I13�J0N00 �� L Md1d 311S LdS- SELOAN30AN ° �bdniomjiS 2JOd S1NIH3?Jinoi?J 3000 ONlanln8 `8L2 (10b) I1n1I1SNl 313HONOO Nb01?J3Wb o L 133HS 31111 L01- SELOAN30AN 3 Sa?J`daNb1S 1HOId IH1 NO ONIM070d IH1 d0 No>I11aI 1S31b� IHl H11M J.�dWOo 7bHS Ji�IOM S,?J010b?J1N008nS 38 ��IM NOI1bNI1SIa `a� NIbW/I SZ >i?JOJ\ MIN O1NO 1HON N?Jnl `aN(� NIVH NO /wIS Ol 1d3� N?Jnl AMI na N l �N iAAvaa °_ 0 3003 NOUO0 Ji0�Jd ONINIHOI� 800Z-08L bddN :3000 N011031O?Jd ONIN1H01� `ad NIVH O1No 1HOId Ndnl `SO L a�J /dNnoo O1NO 1d3I N�inl `a� �S2J3aNb�ld MO��Od of 3nNIlN00 0 n. `0?1 S)\bB NO1dWdH-abIH2IInl?J/a�J S?J30Nb-ld OlNO ilX3 aRJ2 IHA 3Ab1 `3-13?J10 01ddb?Jl 3H1 lb 3 a 0 L OZ - 31b1S A?JO% MIN d0 Ia00 32JId 3000 J.11dbS Idly/I2JId `�Ja 1N3OnN/I V6 abo?J /�LNnoo O1NO 1HON 1HOI�S `(S LS ab0?J J\1Ninoo 2JOd SNOIS) ?JG 1N3onN/3 � 0• 800Z - (03N) t6 ab0�l /dNn00 SG�IbM01 1HOI?l 1HORS 3 t6 Ob02J Jl1Nn00/S -VZ-JOIN Mo7od Ol InNI1N00 S 3Ab o SG JbMa3/3 t6 ab02J /.1Nn00/S t�Z-/.N OINO 1HOPJ N�Inl `Nol?J3/� VO/S)\VO NO1dWbH SmJbM01 -bZ-JIN Z0� NOIS1�3�1 Z LOZ/t�0/0 L a3nSSl 31ba u 3000 Ib012J10II3 �VNOIlbN-OL (bcddN) NOIlb100SSb NO110310�1d 36d �VN011bN :I000 �VOId10I�3 ?JOd LL lIXI IAbl `aNbISl ONO N?J31SbI Sa�JbM01 JIdXI aNb�Sl ONO ,/3 56-V-I OlNO 3m3W Ol 302 c OLOZ - 31b1S A?JO% MIN d0 I100 ONlanln8 I000 ONIa31n8 IIX3 3Ab1 `/.M>id OWS1 SSO213 O1NO ilX3 3H1� 3�Ibl-`GVOd 701 Wl(I1�Jbd `S 56Z-I O1NO 3nNI1N00 �33Hs ���a �� =- /.dXI XNO2J8 SSO210 O1NO 1HSI?J 1HOI�S N 961 01No 3nNllN Oo >1�10% MIN 9WIl1N3 abO�J o 701 �bll�lbd `N �I�3� ?Jlddn 56 31b1S?J31N1 OlNO InNI1N00 `N SSI�d;X3 86 31b1S?JI1N1 O1N0 IO?JIW `3 SSI?JdX3 08 31b1S?131N1 OlNO 1d3� 1HOI�S `3 08-1 O1NO 39d31W (INb /AK/l M3N/NOS2J31bd/3 /.11�10bd SNOI1b01NnWW0o3�31 :3Sn a3SOdO�Jd 0 a 'NOIS3a IHl N�13n0O ��bHS a?JbMb 10b?J1N00 O ° 08-1 �IOd SNOTS M070A /.110 Ai JO). MIN SG�JVMol 3 08-1 ?JOd blt� UX3 3�1b1 N L8Z-I O1No 30?13W 0 d0 Ilba 3H1 NO 103dd33 NI Sa�IbaNb1S (INb SIa00 a3ldoab f Hb :]Hi d0 NOIlla3 3H1 Ol 1d3� N?Jnl `3�b' NOSIObW O1N0 1d3� 1HOI�S `1S H1nOS MO��Od Ol 3nNI1N00 `1S H1noS/0 LS ab'0?J J�11�10bd SNOIlb01NnWW0o3�31 3Sn 1N3�Idn0 0 C 'NOIlb00� IH1 ?JOd (f Hb) NouoiaSl�lnf ONIAbH J�ll?JOHlnb �b00I 3H1 /�9 QlldOab Sb SI000 (88 a�`dN) �SWb �,LL NOIlb�3�3 0 �b00� aNb `31b1S `�bN011bNJ 3�8b01�ddb I�b H11M J.�dW00 ��bHS �i�IOM S,2J010b?J1N008nS /.1Nn00 OINO 1HON N?Jnl `ai �1171W OlNO ll] J1S SSO213 a�� 3H1 iT 1J3I N?Jnl `3Ab Homy noon OlNO 1HO12J N2Jn1 `J\`dM >10?JWbZ Sa�JbM01 ]AV 318W3A 1W/N ZOZ-Sn NO 1SbI-H1�lON ObIH (28 a NbN) „8S ,L L eZL M IOn11ON0� cn o :f N`NMOlSIaaOW WOa-A (28 abN) „�� ,8 .lt N :3anlliv� A =3 Sa V(3Nv..S a NV S3000 JNlanln8 3�18VOIlddd ddW AlINl3ln 101�11SIa Jl11SN3a M0� �bI1N3aIS3?J 0 08d 101?J1SIa ONINOZ 8'2 L l0I `S A30I8 "9 L N01103S :al Xbl /.. 13dO2Jd o rn .t GIOH1nos d0 NMOl :N01101aSl�jnf 096LO f N `NMolSl?]KW ® InN3Ab 1�9WND1 '1W 0t2 � =3 J= N� 1 0 („1�81b„) o�� Sod Ss3�I�lIM ?JbinONIO MIN SSI?Jaab 1Nb01�ddb d m H 0CD ° — o Aveh °OjAH ® n ® L96L L /.N `1N31d0 I ab0?J NIVH OH2Z o n 10l�JiSla 3?JId 1N31�10 3H1 :�J3NMO /.d3do?Jd rn o - LS6 L L ).N `1NRJO ° -v ab0�l NIbW 00HZ :SS3�10ab I11S a NOI.LVINHOMI .Lo3rodd D : � =r R. O a31Vl3OSSV aNb SbNNI1Nb `1N3Wdin03 d0 ONISI?JdHOD /.11�lobd W003I31 ONIISIX3 Ol NOIlb0ldIGOW °� 0 rn N0lJ.dlEl3S3a m3roHd cn co .� MAIN ROAD ( S. R . 25) a o N 80' 31'_30" E m � N � - - - - - - 226.00' - - - - - - � 43 o -� p 10 •� � w I� I d 0 00 w U 0 1 I am L- PAVED O v toAREA Po -co c a; Nlm o W 79'—7„t o l � I � aci EXISTING FIRE v 3 STATION o75'-5"± � (o c r v �n N 1 I c "0 U I v PAVED PAVED -0 o Q AREA AREA 0 0 L L- I � - i ° 1 / N8 _47 30 E c � a 1 � � , � E I 0 I : EXISTING 112'-4 t Q) t 1 PAVED BUILDING4-0 I' AREA o c / / o � / c c +' o t +� c 0o 1 \ � v 1 o L. cn m 0 0 A (SEE DETAIL 1/fA01) N a� v� 1 C",lor 1 � 0 0 I o--'- r- o �, w IQ N SUBJECT SITE: ORIENT FIRE 1 v L M DISTRICT SECTION 18 1 E o M BLOCK 05 LOT 13.8 o -«� o v '- o o 1 U 1 •� � 1 1 v Q c o > L _ _ _ _ _ _ S 83- 03' 50" E 570.70 co -c �- rn 4-0 c c NOTE: BASE MAP INFORMATION OBTAINED FULL SCALE 1 "=30'—O" 0 3 FROW DRAWINGS PREPARED BY APT SITE PLAN 1 NOTE: TO THE BEST OF OUR KNOWLEDGE, THE 30 15 0 30 60 FT 0 ENGIINEERING, DATED 03/07/12 AND LAST SCALE: 1 "=30'-0" SP1 PROPOSED EQUIPMENT MODIFICATIONS BY AT&T o UPD/ATED ON 04/06/12 AND A SITE VISIT WILL HAVE LITTLE IMPACT ON THE EXISTING o- HALF SCALE 1 "=60'-0" " v 0 PERFORMED BY BECHTEL ON 05/26/2012. NOISE LEVELS AT THE EXISTING FACILITY. U ,Fn L- 0) SITE NAME: ORIENT POINT °F NEB =q� at&t w BECHTEL ASSOCIATES G,zs ° "'• c9�"p�. m cn PROFESSIONAL CORPORATION SITE NUMBER. NYCENY0735 ¢ o I o -a) A UNIT OF BECHTEL CORPORATION 23300 MAIN ROAD 1 01/10/13 LTE-ISSUED FOR CONSTRUCTION AS GS RC •� SITE PLAN t L ORIENT, NY 1 1957 0 01/04/13 LTE-ISSUED FOR CONSTRUCTION AS GS RC o, 3 5275 WESTVIEW DRIVE `� �. .� °' FREDERICK, MD 21703-8386 USA NO. DATE REVISIONS BY CHK PPS 'F�p�4S439-P���'�' E257 NUMBER DRAWING NUMBER REV >, 'C 0•° = SCALE: AS NOTED DESIGNED BY: AS DRAWN BY: As ROF�$$1ON 6-415 T3—NYCENY0735 SP 1 1 U 11 SIZE 22 x 34 ANSI D N GENERAL NOTES U m 1 . FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL �- EXISTING FIRE HOUSE APPLY: 0 CONTRACTOR - BECHTEL a SUBCONTRACTOR - GENERAL CONTRACTOR (CONSTRUCTION) 3 OWNER - NEW CINGULAR WIRELESS PCS, LLC ("AT&T") -° .��` v OEM - ORIGINAL EQUIPMENT MANUFACTURER v v a o 2. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING SUBCONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN 0 o waa x x BE ACCOMPLISHED AS SHOWN ON o ++ THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY M o x ++ VEIRIZON FOUND SHALL BE BROUGHT TO THE ATTENTION OF CONTRACTOR. U ���' EQUIPMENT EXISTING x ° - "Mel ++ VERIZON 3. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL c °' x + SHELTER x—x � ++ ++ + GENERATOR x APPLICABLE CODES, REGULATIONS, AND ORDINANCES. SUBCONTRACTOR SHALL ISSUE ALL EXISTING CONCRETE RULES REGULATIONS AND t x + ++ ++ + x/—PAD APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDIINANCES, , 0° '" �' LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. T�7_,q + + n l •C` Y x + + /I x v 3 �x +. + + 4. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY a + + + a < n + + + PROPOSED GPS UNIT ON EXISTING ICE BRIDGE POST COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE o ++ x 4& PROPOSED 1/2" COAX CABLE ROUTED TO BBU REGULATIONS. ++ ((PROVIDE 10' MINIMUM SEPARATION FROM ANY v EXISTING ++ x (EXISTING ANTENNA) (SEE DETAIL 1121A/A05) 5. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, 04 I AT&T ICE \ EXISTING NEXTEL x APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON •- BRIDGE EQUIPMENT SHELTER EXISTING FLAGPOLE THE DRAWINGS. -° a�, x ' ° o EXISTING \ 6. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH o v AT&T. EXISTING AT&T CABINETS MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. a x EQUIPMENT �: ' x ° CABINETS i4Av�. . . . . . JrI. . .. . +. . . .i.. (EXISTING VERIZON CSC CABINET x . . .. .'''''''''''''''''''''''' ' '' ' x 7. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE o v SUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE +• CONTRACTOR. •.i, I :r x . as .`ra POWER & I 'a",, ,;�•, SUBCONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUIT, POWER AND T1 CABLES, ° � TELCOEXISTING N8. EXISTING AT&T « , X STING TRANSFORMER GROUNDING CABLES AS SHOWN ON THE POWER, GROUNDING AND TELCO PLAN DRAWING. -v E L- —x—x—x_ EQUIPMENT PAD E I SUBCONTRACTOR SHALL UTILIZE EXISTING TRAYS AND/OR 'SHALL ADD NEW TRAYS AS x x x x— .� Tx x—x—x—x— —x x NECESSARY. SUBCONTRACTOR SHALL CONFIRM THE ACTUAL ROUTING WITH THE CONTRACTOR. o ''14 I i , W ti•M. ROUTING OF TRENCHING SHALL BE APPROVED BY CONTRACTOR. la r471f." `+1 i•f .� • `A i .A: .a H: i .Pad -v EXISTING FENCE 9. THE SUBCONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, +' LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT ° .c: EXISTING GATE 1 SUBCONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWINER. v c �O3 10. SUBCONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH FULL SCALE 1 /8"= 1 '-0" U AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. .� SITE PLAN 1 8 0 8 16 FT a� ° SCALE: 1 /8"= 1 '-0" A01 11 . SUBCONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. E HALF SCALE 1 /16 =1 -0 � 12. ALL CONCRETE REPAIR WORK SHALL BE DONE IN ACCORDANCE WITH AMERICAN CONCRETE m o INSTITUTE (ACI) 301 . 0 .� N 13. ANY NEW CONCRETE NEEDED FOR THE CONSTRUCTION SHALL HAVE 4000 PSI STRENGTH AT 0 28 DAYS UNLESS OTHERWISE SPECIFIED. ALL CONCRETING WORK SHALL BE DONE IN •° ACCORDANCE WITH ACI 318 CODE REQUIREMENTS. c ° a Q° EXISTING FLAGPOLE 14. ALL STRUCTURAL STEEL WORK SHALL BE DONE IN ACCORDANCE WITH AISC SPECIFICATIONS. o v, SIEC��S 15. CONSTRUCTION SHALL COMPLY WITH SPECIFICATION 25736-000-3PS-AOOZ-00001 , v •L --� GENERAL CONSTRUCTION SERVICES. L '� 1 6. SUBCONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO ° EXISTING (2) MHA'S TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE c v, ° REMAIN (TYP EACH SECTOR) v t DRAWINGS MUST BE VERIFIED. SUBCONTRACTOR SHALL NOTIFY THE CONTRACTOR OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 0 • ��� SWAIP (1) AT&T ANTENNA FOR PROPOSED LTE AT&T �'G� 17. THE EXISTING CELL SITE IS IN FULL COMMERCIAL OPERATION. ANY CONSTRUCTION WORK ° ANDIREW ANTENNA (SEE DETAIL 1510&2/A03) & o G�CO ADD, (2) DIPLEXERS (SEE DETAIL 1/A05) (SECTOR A) BY SUBCONTRACTOR SHALL NOT DISRUPT THE EXISTING NORMAL OPERATION. ANY WORK ON S� 2 EXISTING EQUIPMENT MUST BE COORDINATED WITH CONTRACTOR. ALSO, WORK MAY BE .o ¢ SCHEDULED FOR AN APPROPRIATE MAINTENANCE WINDOW USUALLY IN LOW TRAFFIC PERIODS 0 AFTER MIDNIGHT. SWAMP (1) AT&T ANTENNA FOR PROPOSED LTE AT&T > n� ANDDREW ANTENNA ((SEE DETAIL 1510&2/A03) & 0 SWAP (1) AT&T ANTENNA FOR PROPOSED LTE 18. SINCE THE CELL SITE MAY BE ACTIVE, ALL SAFETY PRECAUTIONS MUST BE TAKEN WHEN E AT&T ANDREW ANTENNA (SEE DETAIL 1510&2/AO3) �' ADD► (2) DIPLEXERS (SEE DETAIL 1/A05) (SECTOR B) WORKING AROUND HIGH LEVELS OF ELECTROMAGNETIC RADIATION. EQUIPMENT SHOULD BE LTE ANTENNA AZIMUTHS SHOWN ARE PRELIMINARY & ADD (2) DIPLEXERS (SEE DETAIL 1/A05) �° �J SHUTDOWN PRIOR TO PERFORMING ANY WORK THAT COULD EXPOSE THE WORKERS TO :co AND MAY NOT REFLECT FINAL RF DESIGN. REFER (SECTOR C) DANGER. PERSONAL RF EXPOSURE MONITORS ARE REQUIRED TO BE WORN TO ALERT OF ANY ~ C' TO LATEST RF DATA SHEET FOR FINAL LTE DANGEROUS EXPOSURE LEVELS. ANTEINNA SPECIFICATIONS, AZIMUTHS, TILTS, ETC. 0 0 c .-�� NOTES: FULL SCALE 3/4"= 1 '-O" DETAIL 0 3. 12" 0 1 2 3 FT ril0 -w 1 . ANTENNA ORIENTATION/AZIMUTHS SHALL BE FIELD VERIFIED. ANTENNA PLAN 2 E Z 2. EIQUIPMENT/ANTENNAS BY OTHERS NOT SHOWN FOR CLARITY. �01 SCALE: N.T.S. °- SCALE: 3/4"= 1 '-0" A01 HALF SCALE 3/8"=1 '-0" 0 0 U •cn cn L_ 0 SITE NAME: ORIENT POINT ��°F,a�,�� t&� z BECHTEL ASSOCIATES Q o m PROFESSIONAL CORPORATION SITE NUMBER: NYCENY0735 co 4 �a v 23300 MAIN ROAD & 1 01/10/13 LTE-ISSUED FOR CONSTRUCTION AS GS RC * * SITE PLAN, ANTENNA PLAN & A UNIT OF BECHTEL CORPORATION ORIENT, NY 11957 0 01/04/13 LTE-ISSUED FOR CONSTRUCTION AS GS Rc a GENERAL NOTES •v) 3 .c 5275 WESTVIEW DRIVE N0. DATE REVISIONS BY CHK �pp'C F O4Sg3g-� ��'\ JOB NUMBER DRAWING NUMBER REV a o •c: FREDERICK, MD 21703-8386 USA °ARo P��" 0 •� — SCALE: AS NOTED DESIGNED BY: As DRAWN BY: AS Fr_ss`°N_ 25736-415 T3—NYCENY0735—AO1 1 U c_Q SIZE 22 x 34 ANSI D CONSTRUCTION NOTES t +' 1 . FIELD VERIFICATION: m o SUBCONTRACTOR SHALL FIELD VERIFY SCOPE OF WORK, AT&T ANTENNA PLATFORM LOCATION AND ANTENNAS TO BE REPLACED. 0 INSTALL (6) PROPOSED RRH'S 2. COORDINATION OF WORK: 3 ¢ & (6) TRIPLEXERS ON PROPOSED SUBCONTRACTOR SHALL COORDINATE RF WORK AND PROCEDURES WITH CONTRACTOR. H-FRAME. (SEE DETAIL 1110D/A04) 3. CABLE LADDER RACK: v �- o INSTALL NEW ICE BRIDGE WITH ICE SUBCONTRACTOR SHALL FURNISH AND INSTALL CABLE LADDER RACK, CABLE TRAY, AND a� BRIDGE POST (SEE DETAIL 1154/AO6) CONDUIT AS REQUIRED TO SUPPORT CABLES. v PROPOSED GPS UNIT ON EXISTING ICE BRIDGE m Q EXISTING GPS UNIT TO POST & PROPOSED 1/2" COAX CABLE + 101 DETAIL REMAIN (TYP.) ROUTED TO BBU (PROVIDE 10' IMINIMUM + + + + �O2 SCALE: N.T.S. c INSTALL DC6 EXCEPTION BOX & FIBER SEPARATION FROM ANY EXISTING ANTENNA) + + + + MANAGEMENT BOX ON EXISTING COAX (SEE DETAIL 1121A/AO5) + + + v m SUPPORT RACK + + + STRUCTURAL STEEL NOTES 0 (SEE DETAIL 1 &1137/A04) + + + + + + 1 . ALL STEEL WORK SHALL BE PAINTED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS a 3 AND IN ACCORDANCE WITH ASTM A36 UNLESS OTHERWISE NOTED. E + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + o 2. ALL WELDING SHALL BE PERFORMED USING E70XX ELECTRODES AND WELDING SHALL 40 � + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + 0 �� _� - -� �+ �- �� �t �- �� t--f -�—f -�+ + CONFORM TO AISC. WHERE FILLET WELD SIZES ARE NOT SHOWN, PROVIDE THE MINIMUM ° + + + + + + + + + + + + + + + + + + + + + + + + + + _+ + + + + + + + + SIZE PER TABLE J2.4 IN THE AISC "MANUAL OF STEEL CONSTRUCTION". PAINTED •� 04 I- + + + + + + + + + + + + + + + + + + + + + + + + �'�,\ + + + + + + + SURFACES SHALL BE TOUCHED UP. -v `` 3. BOLTED CONNECTIONS SHALL BE ASTM A325 BEARING TYPE o v + ��� (3/4"0) CONNECTIONS AND SHALL HAVE MINIMUM OF TWO BOLTS UNLESS NOTED o OTHERWISE. + + L �� 4. NON-STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8" DIA. ASTM A 307 0 ° + '� BOLTS UNLESS NOTED OTHERWISE. -v + o �a + 5. INSTALLATION OF CONCRETE EXPANSION/WEDGE ANCHOR, SHALL BE PER MANUFACTURER'S 0 + EXISTING WRITTEN RECOMMENDED PROCEDURE. THE ANCHOR BOLT„ DOWEL OR ROD SHALL CONFORM a ARGUS EXISTING EXISTING EXISTING EXISTING EXISTING -° E + RGUTE2 NOTINKIA NOTIN PURCELL CCI LUCENT TO MANUFACTURER'S RECOMMENDATION FOR EMBEDMENT DEPTH OR AS SHOWN ON THE -v KIA � + 850 1900 DB MCPA RxAIT UMTS DRAWINGS. NO REBAR SHALL BE CUT WITHOUT PRIOR CONTRACTOR APPROVAL WHEN v 0 POWER CABINET CABINET DRILLING HOLES IN CONCRETE. SPECIAL INSPECTIONS, REQUIRED BY GOVERNING CODES, cn -v + CABINET CABINET SHALL BE PERFORMED IN ORDER TO MAINTAIN MANUFACTURER'S MAXIMUM ALLOWABLE 0 • • LOADS. oEXIS71NG � + + I I\ -=T __ � -� • AC PANEL _ , , 6. ALL EXPANSION/WEDGE ANCHORS SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED. -� + ' i % ` �� i THE ANCHOR BOLT DOWEL AND ROD SHALL BE STAINLESS STEEL WITH STAINLESS STEEL -v i c c + I ,% ,' `� \ o WASHERS. I i O 0 620 DETAIL o + I ��- 0 SCALE: N.T.S. +I _ W L + I --- -' m o ( - 4— ( \ n o •� Lam+ D v i a) + •a PROPOSED PURCELL FLX16WS Q o CABINET, STACKED ON TOP OF p o EXISTING PURCELL CABINETc: j- o °, (SEE DETAIL 1117/AO5) EXISTING AT&T CONCRETE SLAB t 0 + c U — t v_ v INSTALL NEW ICE BRIDGE WITH ICE "- o BRIDGE POST (SEE DETAIL 1154/AO6) 0 f- 22,-2" c � 'v Q .� c > EXISTING TELCO BOX E o .n � a a� U) _c _ -� � rn c vi -v c 4-1 ' NOTE:: FULL SCALE 3/4"=1 '-0" � ,0 F PRESENTLY THERE ARE 5 RECTIFIERS, UPON THE EQUIPMENT PAD 1 12" 0 1 2 3 FT v 0 COMPLETION OF THE LTE UPGRADE, THERE SHOULD -SCALE: 3/4" 1 '-0" A02 0 BE Al TOTAL OF 7 RECTIFIERS SHOULD BE PRESENT, - o- HALF SCALE 3/8"=1 '-0" L c 2 NEW RECTIFIERS SHOULD BE ADDED BY LTE. 0 cn . L SITE NAME: ORIENT POINT °Fp M��''� �t&t L.CL BECHTEL ASSOCIATES Q 0 0 m co PROFESSIONAL CORPORATION SITE NUMBER: NYCENY0735 c 1 01/10/13 LTE—ISSUED FOR CONSTRUCTION AS GS RC "� EQUIPMENT PLAN & NOTES 0 4 IA UNIT OF BECHTEL CORPORATION 23300 MAIN ROAD p ORIENT, NY 1 1957 / /3 t 5275 WESTVIEW DRIVE 0 01 04 13 LTE—ISSUED FOR CONSTRUCTION AS GS RC � w i C v_, NO. DATE REVISIONS BY CH K PP'C 04S413 �?�'' JOB NUMBER DRAWING NUMBER REV 0- 0 �" FREDERICK, MD 21703-8386 USA AR P• : SCALE: AS NOTED DESIGNED BY: AS DRAWN BY: As °F�ss+o U N. 25736-415 T3-NYCENY0735-AO2 1 •aQ i SIZE 22 x 34 ANSI U 6.7" TOP OF EXISTING FLAGPOLE .V '` _ 5.1 " 2„0 — 4.5"0 - 2"0 — 4.5"0 MOUNTING POLE f90'-0" A.G.L. m MOUI�JTING POLE I 4.7" (MIN.) o 3.5" ;� 17.6" (MAX) Q ' 2.7" ' _ 0.7 3 ' OF EXISTING NEXTEL ANTENNAS �T c f85'—O" A.G.L. J C� O � r- O TOP OF AT&T ANTENNAS ma� a °' ' (TYP. FOR ALL SECTORS) U f77'-3" A.G.L. c _uyu c SWAP (1) AT&T ANTENNA FOR PROPOSED LTE 0° I ( AT&T ANDREW ANTENNA SEE DETAIL 1510&2 A03 -� I & ADD (2) DIPLEXERS (SEE DETAIL 1/A05) v 3 (TYP. ALL SECTORS) OF EXISTING VERIZON ANTENNAS 0 MECHANICAL SPECIFICATIONS : f65'-0" A.G.L. J- c WEIGHT = 5.5kg/12.11bs v m MATERIAL = GALVANIZED STEEL co N �> I O' i C --nl o I 00 D� 0- 0 O L 00PID z O v N Z (D v o a 2.7" 0 I EXISTING WHIP 3.5" ' ' I ANTENNAS . =3 o FRONT ELEVATION SIDE ELEVATION co -o (OR APPROVED BY THE ENGINEER) I •_ POWERWAVE (7256.00) HEAVY DUTY _ C TILT BRACKET KIT r1510 SCALE: N.T.S. A03 U I •0 12 ) 6.5" E o I EXISTING 90'-0" FLAGPOLE mo O •c -FJ a ao .� PR(OPOSED GPS UNIT ON EXISTING ICE I ROUTE OF EXISTING o FRONT 0 NT BRIIDGE POST & PROPOSED 1/2" COAX I CABLES ° �+ N CAIBLE ROUTED TO BBU (PROVIDE 10 I o MIN41MUM SEPARATION FROM ANY EXISTING r ANITENNA) (SEE DETAIL 1121A/A05) I v I v EXIISTING GPS UNIT TO o 0 REWAIN (TYP.) c0 EXISTINIG 6'-0" CHAIN C . LINK FEENCE EXISTING AT&T C � ANTENNAS FRONT ELEVATION SIDE VIEW J o MECHANICAL CHARACTERISTICS WEIGHT: 33.951b (15.40kg) NOTE: ANTENNA CONFIGURATION AND AZIMUTHS TO BE FIELD VERIFIED. �? WIND LOAD (@150 km/h): (413.4N) o 4-1 MAX. WIND SPEED: 150mph (241 .4 km/h) GRADE LEVEL LTE ANTENNA 0'-0" AGL J FULL SCALE 3/16"=1 '-0" z 2 DBXNH- 6565A-A►2M FLAGPOLE ELEVATION 1 4 0 4 8 12 Fr a A03 SCALE: 3/16" = 1 '-0" LE3 0 o SCALE: N.T.S. HALF SCALE 3/32"= 1 '-0" SITE NAME: ORIENT POINT ���p�,� i�, at&t BECHTEL ASSOCIATES m cn PROFESSIONAL CORPORATION SITE NUMBER. NYCENY0735 co c 1 01/10/13 LTE-ISSUED FOR CONSTRUCTION AS GS RC ,* 9 * FLAGPOLE ELEVATION & DETAILS °' A UNIT OF BECHTEL CORPORATION 23300 MAIN ROAD -° L 040�0 5275 WESTVIEW DRIVE ORIENT, NY 1 1957 " o 01/04/13 LTE-ISSUED FOR CONSTRUCTION As cs Rc, y \2� •� 3 FREDERICK, MD 21703-8386 USA NO. DATE REVISIONS BY CHK PP �'FppR48439' JOB NUMBER DRAWING NUMBER REV a o SCALE: AS NOTED DESIGNED BY: AS DRAWN BY: AS QFESS'°NP 25736-415, T3—NYCENY0735— A03 1 U aQ SIZE 22 x 34 ANSI D co 4'-60P +; �>• EXISTING ICE PIPE CAP a (NP) BRIDGE POST (TYP.) M � DC6 EXCEPTION BOX :.:.:.:.:.:.:.:.:.:. .:.:ICE BRIDGE:.:.:.:. . .:.:.:. .:.:. SEE DETAILS 1137/A04) . . . . . . . . . . . . . . . . ° . . . . . WIDTH PROPOSED FIBER Q DIPLEXER MANAGEMENT BOX •3 a 3 1,/2"0 ICE 10 ° ° ° — o BRIDGE POST I I I I I I I I I I I I o (TYPO) 0 I I I I I I I I I I I I m 10 ° 1 1 1 1 1 1 1 I ° U c m O Z \ = W � o � o o 4" 4„ o wr 00 rn ro I of ° ° ° a v 3 0 ° — E TO ANTENNA ° _0 1 UNISTRUT 1 700 1 1 700 1 1 700 1 \ FIBER ALARM (+45 DEGREE) c M CHANJNELN T 1 RRH 1 1 RRH 1 I RRH 1 ENTRY CABLE PORT ° N OR EQUIVALENT ( FRONT 1 1 FRONT 1 I FRONT I 1/2" COAXIAL CABLE W/ •� .,_, (TYP)) 1 I I I I 17/16 DIN—MALE CONNECTORS v o 0 0 0 o CPRI-M RI-S Q ALM 4-6 n(/RX2� TX/RX1 - �, 0 0 0 -AISG ON BOTH ENDS (2 TYP) c L - - - J L - - - J L — — J GIGE ALM 1-3 (IF USED 'D 0 T d a TO ANTENNA PROPOSED P1000--�/ o U It O FOR RET) O O — z �. \'n ( 45 DEGREE) UNISTRUT (TYP) — o _ MZ TX MON2 O O TX MON1 PORT CONNECTION DC ENTRY '- C r Z GROUND o v ., r - - - � r - - - —i r — - -I RRH BOTTOM VIEW RRH TOP VIEW O 10 01 1 1 0 0 :0 � I I I I I I E I AWS I I AWS I I AWS I ►� SIZE AND WEIGHT TABLE DC POWER SURGE PROTECTION, -6 0 RRH RRH RRH W ° 1 FRONT 1 ( FRONT 1 1 FRONT 1 FIBER MANAGEMENT BOX I I I I I I I RRH WIDTH DEPTH HEIGHT W/O CABLE WEIGHT MOUNTING DETAILS 1 0 ° ° ° ° MANAGEMENT COVER W/O BRACKET 4-0SCALE: N.T.S. �O4 ° .c: L - - - J L - - - J L - - - J \ RRH 7( Mjz 12.2" 10.8 21 51 LBS. 15.220 .D 2X40 80W " c GROUND BAR o z 14.273" 6.370" •u, v RRH AWS ,,, " 43 LBS. .� o (12" MIN. x 2" x 1/4") T 2X40 (80W) 12 9 25 (W/0 SOLAR SHIELD) 13.056 6.273" GRADE _ 12.000" — o ==— = =  = _ _ _ = = = o. = = NOTE: DIMENSIONS INCLUDE I�MOUNTING BRACKET SOLAR SHIELD AND CONNECTORS. i—I I III—I I—I I—I I—III III III III III—III—I I—I I : I—III—� o I I-1 11, I :°°1 1 1-111=1 11=1 I I=1 11-1 11-1 I I-1 11=1 I I-1 I I-1 11=i I i °�1 I I I 1=1 11= _ mo I 1 4- 0 •c u o U MINIMUM CLEARANCE TABLE ° t 12"s� PLAIN RRH CABINET CLEARANCES (INCHES) COMMENTS co CONCRETE OR •c 0 o SAKRETE PIER FRONT 363 INSTALLATION ACCESS 4- MOTES: C t »> ZERO REAR CLEARANCE IS ALLOWED USING o o d' (3) 0.38" 0 rn REAR 2 SUPPLIED MOUNTING BRACKETS O LO 00:w '�- 1 . SUBCONTRACTOR SHALL SUPPLY AND INSTALL UNISTRUT OR EQUIVALENT MOUNTING CHANNELS. In r N TO 1 .2B" v ( ) E RIGHT 4'1" AIR FLOW I- co co CABLE LO o 2. SUBCONTRACTOR SHALL SUPPLY AND INSTALL ICE BRIDGE POSTS AS REQUIRED. p (4) 0.1 4"� •� v LEFT 4'" AIR FLOW „ 3. COAX BRIDGE POSTS SHALL BE 3 1/2"O.D. SCHED. 40 PIPE (ASTM—A36, A53 OR EQUIVALENT). TO 0.65► 0 ,� TOP 12" AIR FLOW CABLE 0 0 0 v 4. SUBCONTRACTOR SHALL SUPPLY (BUT NOT INSTALL) 3/8"0 UNISTRUT BOLTING HARDWARE AND e 00 c o SPRING NUTS. TYPICAL FOUR PER RRU. SUBCONTRACTOR SHALL BAG THE BOLTING HARDWARE BOTTOM 12" CONDUIT ROUTING O 0 AND HANG FROM INSTALLED UNISTRUT FRAME. ac 5. SPACING MAY VARY BASED ON SELECTED EQUIPMENT. ADJUSTMENTS TO SPACING WILL BE MADE ALCATEL— LUCENT 9442 BY RRU INSTALLER. �- REMOTE RADIO HEAD (RRH)_ .313 0 HOLES 0 6). NO PAINTING OF THE RRU OR SOLAR SHIELD IS ALLOWED. (4 TYP) 0 o ROXTEC CF16 +' (D NOTE: E " REMOTE RADIO HEAD (RRH) RACK DETAIL RAYCAP MODEL DC6-48-60-0-1 E IS FITTED � WITH (2) 2—INCH CONDUIT FITTINGS IN PLACE � c SON GRADE WZDIPLEXERG) OF THE ROXTEC BLOCKS. cn RAYCAP DC6-48-60-0-1 B-01 0 3 RRH MOUNTING FOR SECTORS A,B r1l 0D 110& CALCATEL-LUCENT 9442 REMOTE RADIO HEAD (RRH) 4 DC POWER SURGE PROTECTION Kl 13 o Z SCALE: N.T.S. A04 SCALE: N.T.S. A04 SCALE: N.T.S. �O4 0- . L_ 0 0 0 L. °' BECHTEL ASSOCIATES SITE NAME: ORIENT POINT ,��°Fp MFw at&t m �- � 6 � SITE NUMBER: NYCENY0735 � 9��' 0 PROFESSIONAL CORPORATION 1 01/10/13 LTE-ISSUED FOR CONSTRUCTION AS GS Rc * * REMOTE RADIO HEAD (RRH) MOUNTING, -� A UNIT OF BECHTEL CORPORATION 23300 MAIN ROAD $( � FIBER MANAGEMENT BOX & DC POWER SURGE 5275 WESTVIEW DRIVE ORIENT, NY 1 1957 0 01/04/13 LTE-ISSUED FOR CONSTRUCTION As Gs RC z�, PROTECTION DETAILS >. L 'C FREDERICK, MD 21703-8386 USA NO. DATE REVISIONS BY CHK PP' Fpp�4S439'N���' JOB NUMBER DRAWING NUMBER I- 0 � •QQ sCALE: AS NOTED DESIGNED BY: AS DRAWN BY: As R�Frrss'°NP 25736-415 T3—NYCENY0735—AO4 SIZE 22 x 34 ANSI to , U O m O q�j -� Q 3 v ° n- o METAL STRAP v (4) 0.69"0 SUBCONTRACTOR HOLES GPS UNIT TO PROVIDE (TYP) \ JUMPER TO U N d m L ANTENNA cU �s q— --- --- — o° o c ���' j INSTALL WEATHER PROOFING SET SCREWS ° ° INSTRUCTIONS ER UNIT UF. � — v DIPLEXER ,,00 ,oG I - COLLAR 1 " (1 -5/16" O.D.) X 3'-0" MAX. o ° SCREW D N PROVIDE APPLICABLE GALV. STEEL OR ALUM. MOUNTING E yes PIPE-TO-PIPE CLAMP PIPE AGROUND WIRE ° TO ANTENNA T o y GROUND CABLE CLAMP (BURNDY ANTENNA MOUNTING GROUND BAR � �� �'- - - - - - - - - - - �' TYPE C-11N OR EQUIV.) PIPE (TYP) N �-�cy9 c� 1 .75" w. FRONT �— INSULATED SPLIT-COLLAR BUSHING (GARVIN 21 .50" ICE BRIDGE POST P/N GCHK100 WITH GROUND LUG REMOVED) -JUMPER OR SIMILAR POST. COAX CABLE TO MAIN o0 0 0 L (W/N-MALE CONNECTOR) FRONT VIEW COAX a° 0 COAX CABLE SUPPORT L � DRILL PATTERN � o v 0 0 :3 6 30" 2 AWG GROUND WIRE CADWELD TO 0 3 POST ONLY IF GROUNDED, OR LUG o �- TO CRGB `P' SECTION OR NEAREST 0 0 o ELEVATION 'P' SUPPLEMENTAL GROUND BAR = o 0 NOTES: (COLLAR MOUNT) ° 0 1 . LOCATION OF UNIT MUST HAVE CLEAR VIEW OF SOUTHERN SKY GROUND PAD PURCELL AND CANNOT HAVE ANY BLOCKAGES EXCEEDING 25% OF THE = JUMPER TO W/4 1/4-20 FLX16WS SURFACE AREA OF A HEMISPHERE AROUND THE GPS UNIT. ANTENNA ° •� BOLTS CABINET -w -° 2. ALL GPS UNIT LOCATIONS MUST BE ABLE TO RECEIVE CLEAR C c 1 " KO's (TYP) SIGNALS FROM A MINIMUM OF FOUR (4) SATELLITES. VERIFY WITH METAL STRAP ,N SAME ON LEFT SIDE HANDHELD GPS BEFORE FINAL LOCATION OF GPS UNIT. SUBCONTRACTOR 0 o " KO's (TYP) TO PROVIDE (TYP) +, 2 ) , - 3. CADWELDING SHALL NOT BE PERFORMED ON ROOFTOPS. o EMPTY W/BLANK DOOR = 80lbs SAME ON LEFT SIDE It"" �� r- DIPLEXER ANTENNA MOUNTING -� v EMPTY W HEAT EXCHANGER = 120lbs ' �' i "� 4. LTE-GPS UNIT SHALL BE LOCATED 10' FROM ALL UNIT. PIPE (TYP) s / ' HEAT EXCHANGER �' , � " E EQUIPMENT (VARIES) = 400/Ibs MAX ', ;', v � ' m o It CABINET TOTAL (MAX) = 600lbs ��\ It '� _ GROUND WIRE ,-, ° LTE GPS UNIT ` ��; '►� TO ANTENNA ' NOTES: ��� PIPE & L_B RACKET MOUNT GROUND BAR .° � == c \ '; JUMPER TO a a 1 . DOOR HINGE MAY BE REVERSED � t a o 2. MINIMUM ANCHOR SIZE MUST BE 1/2"DIA. ►i't % MAIN COAX .4-0 3. AN ISOLATOR BASE IS REQUIRED WHEN MOUNTING I o Q, DIRECTLY ON CONCRETE PAD. 'i' _ SIDE VIEW E �'--------- O + 4- PLAN v :.N c C -N U •- 4- O O U O I— •v Q -4-1 c 0 U > O o v a� PURCELL FLXI6WS CABINET SPECIFICATIONS rn K117 a �O5 GPS UNIT MOUNTING DETAIL 1121A SCALE: N.T.s. DIPLEXER MOUNTING DETAIL 1 o SCALE: N.T.S. A05 SCALE: N.T.S. A05 v � O 3 v o '— Z O a 0 0 U co co co • c &- °' BECHTEL ASSOCIATES SITE NAME: ORIENT POINT ° NE�, . ` µ B & m PROFESSIONAL CORPORATION SITE NUMBER: NYCENY0735 v v 1 01/10/13 LTE—ISSUED FOR CONSTRUCTION AS GS RC GPS UNIT MOUNTING PURCELL °' ` A UNIT OF BECHTEL CORPORATION 23300 MAIN ROAD r 9 a CABINET & DIPLEXER MOUNTING DETAILS ORIENT, NY 1 1957 0 01/04/13 LTE—ISSUED FOR CONSTRUCTION AS GS RC �� pi 3 I 5275 WESTVIEW DRIVE NO. DATE REVISIONS BY CHK PP' tiro °4sas9•� �?`�� JOB NUMBER DRAWING NUMBER REV >. L •c FREDERICK, MD 21703-8386 USA A 0- 0 SCALE: AS NOTED DESIGNED BY: AS DRAWN BY: AS RGFESsI0NP ' 25736-415 T3-NYCENY0735-A05 1 U •QQ SIZE 22 x 34 ANSI D U) o r — U O O m o � * INSTALL DRIP LOOP ON ANTENNA CUT POST LENGTH TO SUIT BY a DC2 RRH CABLES AT BOTTOM OF REMOVING UNCAPPED END ',-� — C1 FC12 C2 DC2 RRH TOWER/MONOPOLE. BENDING -C DC6 RM RADIUS PER MANUFACTURERS 12 WIDE ICE BRIDGE. °- c DC2 RRH STANDARDS CUT ICE BRIDGE CHANNEL 0 LENGTH TO SUIT (SEE (NOTES) v D1 D2 D3 BOND SECTIONS TOGETHER WITH 0 6 AWG WIRE. L m a w_ �j C FIGURE 1 — TRUNK CABLE TO JUNCTION BOX L`' �-c MAXIMUM CABLE LENGTHS FOR FIGURE 1 z TRAPEZE KIT c U o ORDER ADDITIONAL TRAPEZE KITS m z AS REQUIRED, TO MAINTAIN D1 LENGTH (FT) MAXIMUM CABLE SPAN OF 3'-0" a� 0 W Cl SIZE C2 SIZE 75 [100 125 150 175 200 250 (TYP) L- - 8AWG 191 166 141 116 91 66 16 w 0 4- 0 8AWG 10AWG 119 103 88 72 56 41 10 U) z o� 12AWG v 75 65 55 45 36 26 6 o v cv 8AWG 3: 145 105 65 25 — — — ANTENNA CABLES ARRANGEMENT '- 1OAWG 10AWG Z 90 65 40 15 — — — w v BY CONTRACTOR 12AWG J 57 41 25 10 — — — = N 0 8AWG N 75 11 — — — — — ° 12AWG 10AWG 47 7 — — — — — a4'va:Q.o v ° 12AWG 29 4 — — — — — 0 o v CABLE C3 MAY BE EITHER 10AWG OR 12AWG. 0j M I CONCRETE PIER =3 LENGTH D3 IS 16 FEET ALL CASES =a RRH .o U C2 `oho Cl o � DC6—RM DOME RRH Q> o RRH 12 , v a D 1 D2 o FIGURE 2 — TRUNK CABLE TO DC6 (DOMEj � � Cl C2 DC2 RRH •� o DC6—RM DC2 RRH NOTES: o DC2 RRH 1 . WHEN USING COMPONENTS AS SHOWN IN STANDARD DETAILS, MAXIMUM ALLOWABLE SPAN BETWEEN D1 D2 SUPPORTS ON A CONTINUOUS SINGLE SECTION OF BRIDGE CHANNEL SHALL BE 9 FEET FOR 10 FEET a> E BRIDGE CHANNEL. Ill o o .c FIGURE 3 — DIRECT CABLE TO DC2 2. WHEN USING COMPONENTS FOR SPLICING BRIDGE CHANNEL SECTIONS, THE SPLICE SHOULD BE c PROVIDED AT THE SUPPORT' IF POSSIBLE, OR AT A MAXIMUM OF 2 FEET FROM THE SUPPORT. o MAXIMUM CABLE LENGTHS FOR FIGURES 2 AND 3 .? ? 3. WHEN USING COMPONENTS, SUPPORT SHOULD BE PROVIDED AS CLOSE AS POSSIBLE TO THE ENDS o D1/D2 LENGTH (FT) OF ICE BRIDGES, WITH A MAXIMUM CANTILIVER DISTANCE OF 2 FEET FROM THE SUPPORT TO THE 0 CABLE 8AWG 10 AWG 12 AWG FREE END OF THE ICE BRIDGE. 0 C1 265 165 104 4. CUT BRIDGE CHANNEL SECTIONS SHALL HAVE RAW EDGES TREATED WITH A MATERIAL TO RESTORE ETHESE EDGES TO THE ORIGINAL CHANNEL, OR EQUIVALENT, FINISH. o C2 16 16 16 5. ICE BRIDGES MAY BE CONSTRUCTED WITH COMPONENTS FROM OTHER MANUFACTURERS, PROVIDED 'C co THE MANUFACTURER'S INSTALLATION GUIDELINES ARE FOLLOWED. v 6. DEVIATIONS FROM STANDARDS FOR COMPONENT INSTALLATIONS ARE PERMITTED WITH THE RESPECTIVE o MANUFACTURER'S APPROVAL. -v `C o 0 7. DEVIATIONS FROM ICE BRIDGE FOUNDATIONS REQUIRE ENGINEERING APPROVAL. U � C �. •o Q .0 C 0 U ) 0 0 LTE CONDUCTOR SIZES 408 co = ICE BRIDGE DETAILK154 r SCALE: N.T.S. �01 c SCALE: N.T.S. �O6 00 N U C ;+' 0 3 v O L z 0 a � c 0 0 0 •cn ca -6 .- Orp N-v NAME:ASSOCIATES at&t m c coPROFESSIONAL CORPORATION SITE NUMBER: NYCENY0735 o a E' 23300 MAIN ROAD 1 01/10/13 LTE—ISSUED FOR CONSTRUCTION AS GS RC a LTE CONDUCTOR SIZES L co it A UNIT OF BECHTEL CORPORATION 0 01/04/13 LTE—ISSUED FOR CONSTRUCTION AS GS RC & ICE BRIDGE DETAIL rn 3 -c is 5275 WESTVIEW DRIVE ORIENT, NY 1 1957 _ . L FREDERICK, MD 21703-8386 USA N0. DATE REVISIONS BY CHK PP FiD 439'P����'. JOB NUMBER DRAWING NUMBER REV A 0 '� OFESSION. 0•Qa SCALE: AS NOTED DESIGNED BY: AS DRAWN BY: AS 25736-415 T3—NYCENY0735—A06 1 SIZE 22 x 34 ANSI D � A t = U :p O O m � o COAXIAL SURGE ARRESTORS -- -� - - -� (TYP FOR 6) 3 ' COAX TO TOWER 0 .0 o NOTES: M �- 1 . FURNISHED BY AT&T. 2. INSTALLED BY BECHTEL. 0 DIPLEXER DIPLEXER DIPLEXER DIPLEXER DIPLEXER DIPLEXER 3. FURNISHED BY BECHTEL. •� NOTES 3, 4 NOTES 3, 4 NOTES 3, 4 NOTES 3, 4 NOTES 3, 4 NOTES 3, 4 4. INSTALLED BY BECHTEL. c 5. FURNISH AND FINAL CONNECTION BY ERICSSON. m 6. LFMC TO BE PROVIDED BY GC. 7. DELETED 0 3 8. DELETED o -w 9. BREAKERS TO BE TAGGED AND LOCKED OUT. 10. SIAD IS FURNISHED AND INSTALLED BY OTHERS AND INCLUDES POWER CONNECTIONS AND CABLE co COAX JUMPERS TO THE NETWORK INTERFACE DEVICE OR AS SCOPED BY MARKET. op, NOTES: 3, 4 11 . LEC TO FURNISH AND INSTALL NETWORK INTERFACE DEVICE. cv (TYP FOR 12) 12. COIL EXTRA LENGTH OF FIBER CABLE(S) WITHIN FIBER MANAGEMENT BOX OR TRAY (NOT SHOWN) INSTALLED IN PURCELL CABINET AS SITE CONDITIONS ALLOW. 13. BECHTEL GC TO MAKE MEASUREMENTS PRIOR TO INSTALLATION FOR APPROPRIATE CABLE LENGTHS. MOUNTED ON 700 RRU AWS RRU 700 RRU AWS RRU 700 RRU AWS RRU 14. SINGLE-CONDUCTOR DC POWER CABLES SHALL BE TELCOFLEXO OR KS24194m, COPPER, UL LISTED -0 0o WALL OR NOTES NOTES NOTES NOTES NOTES NOTES RHH NON-HALOGEN, LOW SMOKE WITH BRAIDED COVER, TYPE TC (1/0 AND LARGER). UNLESS 0- 0 UNISTRUT RACK 1 , 2, 5 1 , 2, 5 1 , 2, 5 1 , 2, 5 1 , 2, 51 1 , 2, 5 OTHERWISE NOTED, STRANDING SHALL BE CLASS B (TYPE III) FOR CABLES SIZES 14, 12 & 10 AWG AND CLASS I (TYPE IV) FOR SIZES 8 AWG AND LARGER. CABLES SHALL BE COLOR CODED RED FOR +24V, BLUE FOR -48V AND GRAY FOR 24V AND 48V RETURN CONDUCTORS. o v MULTI-CONDUCTOR DC POWER CABLES SHALL BE COPPER, CLASS B STRANDING WITH FLAME 0 a i i i i i RETARDANT PVC JACKET, TYPE TC, UL LISTED FOR 90-C DRY/ 75-C WET INSTALLATION. O m �- _n -�-- -� -J- -�- 6 AWG 15. DC SURGE SHELF SHALL BE RAYCAP DC6-48-60-RM. SEE DETAIL 1409A FOR IINTERNAL WIRING v a - m - m - - - - (TYP FOR 6) DIAGRAM. m 16. SEE DETAIL 1150J FOR ALARM CABLE REQUIREMENTS. M � _n 17. SEE DETAIL 1505A FOR GPS ANTENNA AND SURGE SUPPRESSOR COAXIAL CABLE' CONNECTION. a� 0 2/C 12 AWG DC CABLES Fu -° - NOTES 3, 4, 5, 13 � (TYP FOR 6) ROUTED IN 1 1/2 RNC/LFMC CONDUIT OR TRAY oC •c PURCELL (FLX16WS) u, v LTE OUTDOOR CABINET o 0 2 COUNT, SINGLE MODE FIBER NOTES: 1 , 2 FIBER CABLE FIBER FIBER GPS __j ' =I _ o NOTES 3, 4, 5 SURGE NSUPPRESSOR NOTE: 3, 4, 12 GPS 01 U (TYP FOR 6) RECEIVER UNIT NOTES: 3, 4, 17 o E ROUTED IN LFNC FLEXIBLE DIGITAL--\ NOTES: 1 , 2, 5 Ill � CONDUIT OR TRAY CABLE o 2 AWG �, (1) LTE DUL 20 PDU - - - 2 AWG a 6 AWG 700 MHz & AWS - - 0 o DC SURGE SHELF 2 AWG C--w NOTES: 3, 4, 15 DC PDU �_ C t (1) 15A FUSE o a, - v - (12) 1/C 10 AWG -- ALARM CABLE o +, (2) 1/C 6 AWG IN NOTES: 1 , 2, 5 cn NOTES: 3, 4 1 " LFMC CONDUIT o NOTES: 3, 4, 6 DUL POWER CABLE NOTES: 1 , 2, 5 a 2;l DC BREAKER PANEL -v - (1 ) 50A & (6) 25A c o BREAKERS 66 BLOCK 1 " LFMC CONDUIT 0 NOTES 3, 4, 9 __ _ ^\ (W/PULL STRING) SYSTEM DIAGRAM , TOWER SITE NOTES: 3, 4, 6 •o Q -- -- - - --- - -- - - SIAD WITH OUTDOOR BASE BAND NOTES 10 AND RRUs AT GRADE O N U > O � BY OTHERS NOTES: 3, 4, 16 DETAIL a� N � 1 NETWORK INTERFACE E01 SCALE: N.T.S. DEVICE NOTE 11 (VARIES BY MARKET) Nv 2AWG C _c OUTDOOR POWER CABINET v 0 L_ z 0 a C 0 0 U •v) cn L_ 0 SITE NAME: ORIENT POINT ,��°gyp M��'� �t&t BECHTEL ASSOCIATES �Q4 90� m N PROFESSIONAL CORPORATION SITE NUMBER: NYCENY0735 , 01/10/13 LTE-ISSUED FOR CONSTRUCTION As cs RC co * i SYSTEM DIAGRAM .°; A UNIT OF BECHTEL CORPORATION 23300 MAIN ROAD 8( rl ORIENT, NY 11957 0 01/04/13 LTE-ISSUED FOR CONSTRUCTION AS GS RC 5275 WESTVIEW DRIVE o NO. DATE REVISIONS BY CHK PP Fp 4S43g- �� JOB NUMBER DRAWING NUMBER REV FREDERICK, MD 21703-8386 USA pROFESSto�??- v as SCALE: AS NOTED DESIGNED BY: AS DRAWN BY: AS - 25736 415 T3-NYCENY0735- EO1 1 SIZE 22 x 34 ANSI D cn r U ( I 1900 OR AWS 700 o I I SECTOR A SECTOR A (2) 1/C 1 AWG U U M o POWER CABLESCL ° SEE NOTE 13 w o w o ov ----- I(TYP EACH E ( ) Ur w - `0 9412 CABINET W/2 + NOTE 12 I + I + I + I + I + I + - - 2/C POWER CABLES m o LD Z U m g Z U _m 0 0 0 0 00 Un Un cn cn cn cn ( ) JUNCTION BOX ( ) ( ) o o �` a U o u_ a m E" 9926 BBU 48V DC _ 00 00 00 3 3 NOTE 11 6 TYP NOTE 6 0 ( ) INPUT ALARM r' � P` r' r- r- a a a a a Q NOTE 141+ 1 -113 ❑ + - ❑U 1 1 1 1 1 1 1 1 1 1 1 1 SEE NOTE 13 (TYP') ( ) 0 _ CABLE as mm UU as mm UU 0 .Z Y A-AWS+ i >, U NC _ + - + - + - + - + - + A-AWS- +_ FIBER & POWER + V o m eAM 700 ALARM m y C A-700+ DISTRIBUTION - c JACKS-]— DC SURGE SHELF RAYCAP DC6-RM + WITH + 0 ccoo (NOTES: 2, 9) �, A-700- _ 48V SURGE PROTECTION ° 3 ALCATEL-LUCENT - + - + - + - + - + - + 6 AVUG / (MIN.) RAYCAP DC2 6 AWG 6 AWG 9926 (BBU) 48V DC _ 2 C 12 AWG MIN. (NOTES 7, 8) NC - - \� co 700MHz INPUT _ POWER CABLES (6 TYP) C TO GROUND TO GROUND ALARM (NOTE 6) v T-, ALARM TO EQUIP. CABINET CABLE O GND BAR T 1900 OR AWS 700 N FIBER PORTS JACKS GND SECTOR B SECTOR B 1 2 3 4 5 6 T1 RJ45 (12) 1/C 12 AWG v .o - 6 AWG p p p p p p JACKS POWER CABLES —l— O U U 0 U TO �- a r j - ° o a a a Q Q a GROUND w o w 0 `- eAM 1900 OR AWS ALARM 0 Lo ,n m Lo m m �; � 1 JACKS r- T_ a 0 w O v z U m z U m g `� ALCATEL-LUCENT cn °- BU 48V DC Ed -48V1+ 1 -10 ❑ 1 + 1 -10 190060R AWS INPUT L: B -° 1 .27 E ALARM O OV �_B-AWS- + + -o JACKS FIBER & POWER a� 0 FIBER PORTS GND B-700+ DISTRIBUTION -° 1 2 3 4 5 6 T1 RJ45 +24V INPUT +24V INPUT 24V TO -48V (CONVERTER B-700- ± 48V SURGE PROTECTION ROTECTION + ' ) co ❑ ❑ ❑ ❑ ❑ ❑ JACKS FEED A FEED B (NOTE 3) WITHI RAYCAP DC2 -w INTEGRAL -48V BREAKER PANEL 6 AWG 6 AWG o (NOTE 3) FACTORY (NOTE 2) (NOTES 7, 8) NC - - WIRING C TO GROUND ALARM TO GROUND 0 ALARM CABLE N .o TERMINAL 1900 OR AWS 700 '- c SUPPORT +GND O/P (NOTE 4) (NOTE 3) i OV BLOCK SECTOR C SECTOR C o 0 STAND ' (4) 1/C 4/0 AWG > - GND I/P ' 6 AWG c POWER CABLES _ 0 2 AWG _ ° - 2 AWG 6 AWG ALARM CABLE TO a rj r L TO GROUND w o x o °0 ° GROUND (NOTE 10) �— �_ (NOTE 5) TO 66 BLOCK ° (THIS SHEET) a w a W 0 TO EQUIP. CABINET GND BAR 0 o m a � o m a 0 0 - NOTES1+ 1 -113 ❑ -(- - ❑ CL 0 0 1 . LABEL THE DC POWER CABLES AT BOTH ENDS OF EVERY WIRE AND IN ANY PULL BOX IF USED. LABEL SHALL BE �__�C_AWS- -AWS+ + + 4-1 DURABLE, SELF ADHESIVE, WRAPPED LONGITUDINALLY ALONG THE CABLE AND STAT7E THE SECTOR, FREQUENCY BAND AND _ FIBER & POWER _ t INSTALL (2) (N) POLARITY; I.E. "A-AWS+". C-700+ 0 v, 250A (BREAKERS DISTRIBUTION 0ji 2. INSTALL IN AUXILIARY EQUIPMENT CABINET + WITH + '� C-700- 3. CABLE TERMINALS FOR +24V INPUT FEED A, FEED B AND REFERENCE GROUND SIHALL BE 2-HOLE: 3/8 ON 1 - 48V SURGE PROTECTION - o 2+V CENTER. RAYCAP DC2 6 AWG 6 AWG c cn 4. INSTALL CABLE TERMINALS FOR FEED A AND FEED B RETURN BACK-TO-BACK ON OPPOSITE SIDES OF PAD USING (NOTES 7, 8) NC - - .v 1 -HOLE 3/8" TERMINALS. C TO GROUND ALARM TO GROUND 5. CABLE TERMINALS FOR CHASSIS GROUND SHALL BE 2-HOLE, 1/4 ON 5/8 CENITER. CABLE OV 6. SEE DETAIL 1408 FOR CABLE SIZES AND MAXIMUM LENGTH. :a 7. SEE DETAIL 1411 FOR INTERNAL WIRING DIAGRAM. CABLE GROUND WIRES NOT SHOWN FOR CLARITY. - 0 8. FIBER AND POWER DISTRIBUTION BOX IS NOT REQUIRED WHEN THE DC CABLE BEITWEEN THE DC POWER CABINET AND � � ' � 6 AWG RRH IS LESS THAN 49 FEET. 9. SEE DETAIL 1409A FOR INTERNAL WIRING DIAGRAM. - v' a PART OF DC POWER PLANT 10. CONVERTER REFERENCE GROUND IS NOT REQUIRED WHEN CONVERTER AND 24V DDC POWER PLANT ARE ON THE SAME TO c RACK OR ENCLOSURE. GROUND - 11 . THE BARE WIRE OF EACH MULTI-CONDUCTOR CABLE AND DRAIN WIRE WHEN A SHIELDED CABLE IS USED, SHALL BE - E CRGB CONNECTED TO THE EQUIPMENT CABINET GROUND BAR. WIRING DIAGRAM , OUTDOOR a, v 12. SEE ALARM BLOCK ASSIGNMENT DETAIL FOR ALARM CABLE CONNECTIONS. a� 13. WHEN A 1900 RRH IS USED INSTEAD OF AN AWS RRH CABLE LABELS SHOULD REEFLECT CORRECT FREQUENCY BAND. BASE BAND AND R R H S ON G R 0 U N D, 14. PROVIDE A JUNCTION BOX, AS SCOPED BY MARKET, TO COIL EXCESS DC POWER .AND OPTICAL FIBER CABLES. (FIBER DC/DC CONVERTER �- c' CABLES NOT SHOWN FOR CLARITY.) rfi vArl4l 04 DETAIL �O2 SCALE: N.T.S. 0 3 :,_, 4- v O - Z 0 a - 0 0 U •N 1w, a> N �.O�a M ,Y �-. at&` L.uo z BECHTEL ASSOCIATES SITE NAME. ORIENT POINT G, a) a 0 A> 0 4 m � PROFESSIONAL CORPORATION SITE NUMBER. NYCENY0735 c� ¢ / p a °_' 23300 MAIN ROAD 1 01/10/13 LTE—ISSUED FOR CONSTRUCTION AS GS RC RIRH WIRING DIAGRAM crl- A UNIT OF BECHTEL CORPORATION ORIENT, NY 1 1957 0 01/04/13 LTE—ISSUED FOR CONSTRUCTION AS GS RC .v) 3 t 5275 WESTVIEW DRIVE NO. DATE REVISIONS BY CHK PPS FO �45439'� �?�'` JOB NUMBER DRAWING NUMBER REV °' FREDERICK, MD 21703-8386 USA d � •L" FESSION_ U •0 SCALE: AS NOTED DESIGNED BY: AS DRAWN BY: AS 25736-415 T3-NYCENY0735-E02 1 SIZE 22 x 34 ANSI D . SYMBOLS ELECTRICAL INSTALLATION NOTES (AS APPLICABLE) S/G SOLID GROUND BUS BAR m 1 . WIRING, RACEWAY, AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS 23. CABINETS, BOXES, AND WIREWAYS SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE OF THE NEC AND TELCORDIA. WITH NEMA, UL, AI`\1S1/IEEE, AND NEC. S/N SOLID NEUTRAL BUS BAR 2. SUBCONTRACTOR SHALL MODIFY EXISTING CABLE TRAY SYSTEM AS REQUIRED TO SUPPORT RF AND 24. CABINETS, BOXES, AND WIREWAYS TO MATCH THE EXISTING INSTALLATION WHERE POSSIBLE. - SUPPLEMENTAL GROUND CONDUCTOR 3 � TRANSPORT CABLING TO THE NEW BTS EQUIPMENT. SUBCONTRACTOR SHALL SUBMIT MODIFICATIONS TO CONTRACTOR FOR APPROVAL. 25. WIREWAYS SHALL BE EPDXY-COATED (GRAY) AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN oTo 2-POLE THERMAL-MAGNETIC v ° DOWNWARD; SHALL B °oE PANDUIT TYPE E (OR EQUAL); AND RATED NEMA 1 (OR BETTER) INDOORS, OR NEMA CIRCUIT BREAKER a o 3. ALL .CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY 3R (OR BETTER) OUTDOORS. o THE NEC AND TELCORDIA. SINGLE-POLE THERMAL-MAGNETIC a JUNCTION BOXES AND PULL BOXES SHALL BE GALVANIZED OR 0 26. EQUIPMENT CABINETS, TERMINAL BOXES, ° ° CIRCUIT BREAKER L. 4{-. CABLES SHALL NOT BE ROUTED THROUGH LADDER-STYLE CABLE TRAY RUNGS. EPDXY-COATED SHIEET STEEL, SHALL MEET OR EXCEED UL 50, AND RATED NEMA 1 (OR BETTER) INDOORS, c v OR NEMA 3R (OR BETTER) OUTDOORS ® CHEMICAL GROUND ROD °c 5. EACH END OF EVERY POWER, GROUNDING, AND T1 CONDUCTOR AND CABLE SHALL BE LABELED WITH COLOR- >. CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1 /2 INCH PLASTIC ELECTRICAL TAPE WITH UV 27. METAL RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY-COATED, OR NON- GROUND ROD) o m PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC & OSHA, AND MATCH CORRODING; SHALL_ MEET OR EXCEED UL 514A AND NEMA OS 1 ; AND RATED NEMA 1 (OR BETTER) DISCONNECT SWITCH c: EXISTING INSTALLATION REQUIREMENTS. INDOORS, OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. METER v 6. POWER PHASE CONDUCTORS (I.E., HOTS) SHALL BE LABELED WITH COLOR-CODED INSULATION OR 28. NONMETALLIC RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2; AND O -E ELECTRICAL TAPE (3M BRAND, Y/ INCH PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). PHASE ° CONDUCTOR COLOR CODES SHALL CONFORM WITH THE NEC & OSHA AND MATCH EXISTING INSTALLATION RATED NEMA 1 (OfR BETTER) INDOORS, OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. [3 CADWELD TYPE CONNECTION c REQUIREMENTS. 29. THE SUBCONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CONTRACTOR v Lo BEFORE COMMENCIING WORK ON THE AC POWER DISTRIBUTION PANELS. ® COMPRESSION TYPE CONNECTION E N 7. ALL ELECTRICAL COMPONENTS SHALL_ BE CLEARLY LABELED WITH ENGRAVED LAMACOID PLASTIC LABELS. ALL EQUIPMENT SHALL BE LABELED WITH THEIR VOLTAGE RATING, PHASE CONFIGURATION, WIRE 30. THE SUBCONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND ---- GROUNDING WIRE CONFIGURATION, POWER OR AMPACITY RATING, AND BRANCH CIRCUIT ID NUMBERS (I.E., PANELBOARD AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD o CIRCUIT ID'.S). AGAINST LIFE AND PROPERTY. o V ° 8. PANELBOARDS (ID NUMBERS) AND INTERNAL CIRCUIT BREAKERS (CIRCUIT ID NUMBERS) SHALL BE ABBREVIATIONS 2 L CLEARLY. . LABELED WITH ENGRAVED LAMACOID PLASTIC LABELS. rll5 DETAIL AGL ABOVE GRADE LEVEL 0 v -o L 9. ALL TIE WRAPS WHERE PERMITTED SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP E03 SCALE: N.T.S. AWG AMERICAN WIRE GAUGE EDGES. USE LOW PROFILES TIE WRAPS. cn o °- BCW BARE COPPER WIRE a 110. POWER, CONTROL, AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE CONDUCTOR -° E (12 AWG OR LARGER), 600 V, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED BTS BASE TRANSCEIVER STATION 0 FOR 90 °C (WET AND DRY) OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED, TRANSIENT VOLTAGE SURGE SUPPRESSION (TVSS) (E) EXISTING UNLESS OTHERWISE SPECIFIED. co EG EQUIPMENT GROUND 111 . SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE CONDUCTOR (6 AWG OR 1 . RF TVSS DEVICES SHALL BE INSTALLED IN ALL NEW ANTENNA & NEW COAXIAL INSTALLATION OR EGR EXTERNAL GROUND RING .° .5 LARGER), 600 V, OIL RESISTANT THHN OR THWN-2 GREEN INSULATION, CLASS B STRANDED COPPER CABLE REPLACEMENTS. o -o RATED FOR 90 -C (WET AND DRY) OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM EMT ELECTRICAL METALLIC TUBING ° c USED, UNLESS OTHERWISE SPECIFIED. 2. SEE DETAIL 116 ANJD 124 FOR ADDITIONAL RF COAXIAL TVSS REQUIREMENTS. GEC GROUNDING ELECTRODE CONNECTION .co v o 0 112. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED OUTDOORS, OR BELOW GRADE, SHALL BE SINGLE 3. AC TVSS DEVICES FOR AC POWER SHALL BE INSTALLED FOR ALL NEW AC PANEL INSTALLATION OR GEN GENERATOR CONDUCTOR 2 AWG SOLID TINNED COPPER CABLE, UNLESS OTHERWISE SPECIFIED. REPLACEMENTS GRC GALVANIZED RIGID CONDUIT 0 113. POWER WIRING, NOT IN TUBING OR CONDUIT, SHALL BE MULTI-CONDUCTOR, TYPE TC CABLE (12 AWG OR 4. THE AC TVSS SHALL BE COMMON MODE TYPE, MINIMUM RATED 120kA SURGE CURRENT, AND HAVE IGR INTERNAL GROUND RING (HALO) m o LARGER), 600 V, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED FOR 90 "C (WET MONITORING LIGHTS WITH FORM C ALARM CONTACTS. THE AC TVSS SHALL BE INNOVATIVE TECHNOLOGIES ,- AND DRY) OPERATION; WITH OUTER JACKET; LISTED OR LABELED FOR THE LOCATION USED, UNLESS ZE PTX120 OR OWNEIR APPROVED EQUAL. THE TVSS SHALL BE CONNECTED TO THE AC SYSTEM THROUGH A IMC INTERMEDIATE METALLIC CONDUIT 0 OTHERWISE SPECIFIED. CIRCUIT BREAKER IIN THE AC PANELBOARD AND SHALL BE MOUNTED INTEGRAL WITH THE PANELBOARD OR DIRECTLY ADJACENTF. MGB MASTER GROUND BAR v 14. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP-STYLE, COMPRESSION WIRE LUGS AND WIRENUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRENUTS SHALL BE RATED FOR OPERATION AT NO LESS THAN 5. T1 TVSS DEVICES SHALL BE INSTALLED IN ALL NEW T1 INSTALLATIONS (TYPE AS APPROVED BY AT&T M) MIN MINIMUM a � 75°C (90°C IF AVAILABLE). N.T.S. NOT TO SCALE a o 6. THE SUBCONTRACTO)R SHALL INSPECT THE EXISTING TELCO SYSTEM FOR TVSS PRESENCE AND REPORT v _w 115. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH FINDINGS TO CONTRACTOR. PVC RIGID (SCH.40;) POLYVINYL ° �' NEMA, UL, ANSI/IEEE, AND NEC. CHLORIDE CONDUIT v •'= 7. SURGE SUPPRESSION AND PROTECTION DEVICES SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE L_ _c 116. NEW -_RACEWAY OR CABLE TRAY WILL MATCH THE EXISTING INSTALLATION WHERE POSSIBLE. NATIONAL ELECTRICAL CODE (NEC) ARTICLE 250, 280, 285, AND CHAPTER 8, AS APPLICABLE. RBS RADIO BASE STATION ° REF REFERENCE •� ° 117. ELECTRICAL METALLIC TUBING (EMT) OR RIGID NONMETALLIC CONDUIT (I.E., RIGID PVC SCHEDULE 40, OR REQ REQUIRED ° RIGID PVC SCHEDULE 80 FOR LOCATIONS SUBJECT TO PHYSICAL DAMAGE) SHALL BE USED FOR EXPOSED rll7 DETAIL C 2:1 INDOOR LOCATIONS. E03 RF RADIO FREQUENCY 0 SCALE: N.T.S. o � 118. ELECTRICAL METALLIC TUBING (EMT), ELECTRICAL NONMETALLIC TUBING (ENT), OR RIGID NONMETALLIC RGS RIGID GALVANIZED STEEL 0 CONDUIT (RIGID PVC, SCHEDULE 40) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. TRANSPORT 71 LINES RWY RACEWAY C SIAD SMART INTEGRATED ACCESS 5 Q 19. GALVANIZED STEEL INTERMEDIATE METALLIC CONDUIT (IMC) SHALL BE USED FOR OUTDOOR LOCATIONS 1 . ALL RACEWAY SHALL COMPLY WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE (NEC, NFPA DEVICE 0 ABOVE GRADE. 70), CHAPTER 8. o TBD TO BE DETERMINED 0 20. RIGID NONMETALLIC CONDUIT (I.E., RIGID PVC SCHEDULE 40 OR RIGID PVC SCHEDULE 80) SHALL BE USED 2. ALL SPECIFIED MATERIAL FOR EACH LOCATION (E.G., OUTDOORS, INDOORS-OCCUPIED, UNDERGROUND; DIRECT BURIED, IN AREAS OF OCCASIONAL LIGHT VEHICLE TRAFFIC OR ENCASED IN REINFORCED INDOORS-UNOCCUPIIED, PLENUMS, RISER SHAFTS, ETC.) SHALL BE APPROVED, LISTED, OR LABELED AS TBR TO BE RESOLVED ca . CONCRETE IN AREAS OF HEAVY VEHICLE TRAFFIC. REQUIRED BY THE NEC. TYP TYPICAL v� 3. METALLIC CONDUIT FOR TUBING FOR T1 LINES SHALL BE BONDED TO GROUND AT BOTH ENDS. VIF VERIFY IN FIELD 21 . LIQUID-TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITS FLEX) SHALL BE USED INDOORS AND OUTDOORS, 4. FOR NOKIA GSM BTFS CABINET ONLY - THE T1 CABLE SHALL BE IDENTIFIED AT BOTH ENDS WITH A M WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. COMPUTER-PRINTEDI SELF-LAMINATING POLYESTER WIRE MARKERS (BRADY CORP. OR EQUAL). USE THE o ° "FROM" LOCATION FOLLOWING TYPICAL ID NAME AT THE NIU AND AT THE NOKIA BTS: ° 22. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION-TYPE AND APPROVED FOR THE ° 3 LOCATION USED. SETSCREW FITTINGS ARE NOT ACCEPTABLE. AT&T UMTS 1 ABBREVIATIONS & SYMBOLS v o LEC CCT# 0 E03 SCALE: N.T.S. 0 0 U 'co to s' b. o w z BECHTEL ASSOCIATES EL. SITE NAME: ORIENT POINT ��°gypF at&t m SITE NUMBER: NYCENY0735 ° a) PROFESSIONAL CORPORATION , 01/10/13 LTE-ISSUED FOR CONSTRUCTION AS GS RC * s * ELECTRICAL, TVSS NOTES, ABBREV. 0 .°' ` A UNIT OF BECHTEL CORPORATION 23300 MAIN ROAD & c �' •'' �' ORIENT, NY 1 1957 0 01/04/13 LTE-ISSUED FOR CONSTRUCTION AS GS RC cc� & SYMBOLS o, 3 5275 WESTVIEW DRIVE tis o •L 0) FREDERICK, MD 21703-8386 USA NO. DATE REVISIONS BY CHK PP E`�A 4s439' ���. JOB NUMBER DRAWING NUMBER REV >. L •L o•° = SCALE: AS NOTED DESIGNED BY: AS DRAWN BY: As ROFESS'°NP- 25736-415 T3-NYCENY0735- E03 1 U aQ SIZE 22 x 34 ANSI D _� . GROUNDING NOTES (AS APPLICABLE) c +' 6 AWG STRANDED Cu m 0 1 . THE SUBCONTRACTOR SHALL REVIEW AND INSPECT THE EXISTING FACILITY GROUNDING SYSTEM AND LIGHTNING WIRE WITH GREEN, 60OV, NEIWTON INSTRUMENT COMPANY INC. PROTECTION SYSTEM (AS DESIGNED AND INSTALLED) FOR STRICT COMPLIANCE WITH THE NEC (AS ADOPTED BY THWN INSULATION o THE AHJ), THE SITE-SPECIFIC (UL, LPI, OR NFPA) LIGHTING PROTECTION CODE, AND GENERAL COMPLIANCE BUITNER, N.C. OR APPROVED EQUAL (SUNLIGHT RESISTANT) •_c Q OR BLACK MARKED WITH TELCORDIA AND TIA GROUNDING STANDARDS. THE SUBCONTRACTOR SHALL REPORT ANY VIOLATIONS OR NO. REQ. PART NO. DESCRIPTION ADVERSE FINDINGS TO THE CONTRACTOR FOR RESOLUTION. 1 AS REQUIRED BY NEC 1 /4"x4"x30" SOLID GND. BAR c INCLUDING TELECOMMUNICATION RADIO LIGHTNING PROTECTION AND AC ND BAR ON - a 2. ALL GROUND ELECTRODE SYSTEMS ( O 2 A-6056 WALL MTG. BRKT. WALL FLOOR a o POWER GES'S) SHALL BE BONDED TOGETHER, AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING OR ON ANTENNA c 0 CONDUCTORS IN ACCORDANCE WITH THE NEC. 0 .2 3061 -4 INSULATORS TOWER ma O4 4 3012-1 5/8"-1 1 x 1 " H.H.C.S. 0 3. THE SUBCONTRACTOR SHALL PERFORM IEEE FALL—OF—POTENTIAL RESISTANCE TO EARTH TESTING (PER IEEE o U 1100 AND 81 ) FOR NEW GROUND ELECTRODE SYSTEMS. THE SUBCONTRACTOR SHALL FURNISH AND INSTALL O 4 3015-8 5/8 LOCKWASHER c +; SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. TESTS >, SHALL BE PERFORMED IN ACCORDANCE WITH 24782-000-3PS—EG00-0001 , DESIGN & TESTING OF FACILITY OO 0 DO (o O v m GROUNDING FOR CELL SITES. DOUBLE CRIMP CONNECTION O 0 O OO 0 O O a 4. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED v 3 COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED INTERIOR 2 3 E c AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. GROUND RING o •� EXOTHERMIC WELDS ANGLE SHOW TO >,(° 5. EACH BTS CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN (WELDING ROHIBITED ILLUSTRATE WELD o IN'SULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, 6 AWG STRANDED COPPER OR LARGER FOR INDOOR 1 2 I 0 4 (W0) ON ROOFTOPS) AT THE LOWEST c N BTFS; 2 AWG STRANDED COPPER FOR OUTDOOR BTS. o POINT ON THE BAR P 0 A %� a ° 6. E�<OTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. 013 2 AWG SOLID BARE TINNED � 0 4" EXOTHERMIC COPPER GROUND CONDUCTOR. o U 7. APPROVED ANTIOXIDANT COATINGS (I.E., CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION 13" 1 WELD EXOTHERMIC WELD TO BURIED GROUND RING AND GROUND BAR 0 AND BOLTED GROUND CONNECTIONS. 0 8. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED WITH STAINLESS STEEL HARDWARE TO THE BRIDGE AND THE TOWER GROUND BAR. ai EACH GROUND CONDUCTOR TERMINATING ON ANY GROUND BAR SHALL HAVE INSTALLATION OF GROUND WIRE ° a 9 ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING ANS. IDNE ANDC TIOTIINATIN TAG TTACHED AT EACH END THAT WILL IDENTIFY ITS ri 1 g TO COAX CABLE GROUND BAR DETAIL CNNECTIE �E04 SCALE: N.T.S. .� 10. MIISCELLANEOUS ELECTRICAL AND NON-ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED SECTION "P" - SIURGE PROTECTORS 0 TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. co co - co 11 . MEETAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING CABLE ENTRY PORTS (HATCH PLATES) (2 AWG) TO TOWER MOUNTED TO TRAINSMIT FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH 6 AWG COPPER WIRE UL APPROVED GROUNDING GENERATOR FRAMEWORK (IF AVAILABLE) (2 AWG) AMPLIFIER UNITS ANTENNA o c TELCO GROUND BEAR (2 AWG) (TMA) (WHEN TYPE CONDUIT CLAMPS. REQUIRED) AND COMMERCIAL POWER COMMON NEUTRAL/GROUND BOND (2 AWG) RECEIVE ANTENNA c 12. GROUND CONDUCTORS USED IN THE FACILITY GROUND AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE +24V POWER SUPPLY RETURN BAR (2 AWG) .U) ° ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC -48V POWER SUPPLY RETURN BAR (2 AWG) 0 o CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE RECTIFIER FRAMES;. TX WEATHERPROOFING - " HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS COAX SUPPRESSION KIT (TYP.) o PVC PLASTIC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (E.G., NON-METALLIC v CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE SECTION "A" - SIURGE ABSORBERS RX1/RX2 RX1/RX2 m o MEETAL CONDUIT. INTERIOR GROUND RING 2 AWG) ) ANTENINA CABLE ° 'S 13. AILL TOWER GROUNDING SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF ANSI/TIA 222. FOR TOWERS EXTERNAL EARTH IGROUND FIELD (BURIED GROUND RING) (2 AWG) / I I KIT (TYP.) c BEING BUILT TO REV G OF THE STANDARD, THE WIRE SIZE OF THE BURIED GROUND RING AND CONNECTIONS METALLIC COLD WATER PIPE (IF AVAILABLE) (2 AWG) % BETWEEN THE TOWER AND THE BURIED GROUND RING SHALL BE CHANGED FROM 2 AWG TO 2/0 AWG. IN BUILDING STEEL (IIF AVAILABLE) (2 AWG) JUMPER CABLES) STANDARD GROUND a i ADDITION, THE MINIMUM LENGTH OF THE GROUND RODS SHALL BE INCREASED FROM 8 FEET TO 10 FEET. I I I I KIT (TYP.) �o SECTION "I" - ISOLATED GROUND ZONE (SEE NOTE) C 0 a ALL COMMUNICATIONS EQUIPMENT FRAMES. ° Q' ISOLATED GROUNDI BAR - IGB (2 AWG) CONNECTOR o WEATHERPROOFING o DETAIL_ NOTES: KIT (TYP.) cco _c -6 1 . EXOTHERMICALL-Y WELD 2 AWG BARE TINNED SOLID COPPER CONDUCTOR TO GROUND BAR. FROUTE CONDUCTOR TO BURIED GROUND RING AND PROVIDE #6 AWG STRANDED Cu +>. FROM TMA WIRE WITH GREEN, PARALLEL EXOTHERMIC WELD. WHEN REQUIRED)) 60OV, THWN INSULATION 02 2. USE PERMANENT T MARKER TO DRAW THE LINES BETWEEN EACH (SUNLIGHT RESISTANT) 0 I-_ SECTION AND LABEL EACH SECTION ("P", "A", "I") WITH 1 " HIGH LETTERS. � CIGBE (GROUND BAR), c REFER TO DETAIL ° Q NOTE: 1 18/EO5 TO NEAR/ c o BELOW ANTENNA U >0 1 . DO NOT INSTALL CABLE GROUND SEE NOTE 2 0 KIT AT A BEND AND ALWAYS DIRECT 0 GROUND WIRE DOWN TO CIGBE2 AWG Cu STRANDED c (RGB) REFERENCE GROUND BAR — DETAIL 2. EXISTING CIGBE MAY BE USED IN WIRE WITH GREEN, CONVENIENTLY LOCATED. 60OV, THWN INSULATION (SUNLIGHT RESISTANT) BONDED TO STRUCTURE 1 19 MASTER/EQUIPMENT GROUND BAR DETAIL OR BOTTOM BAR. 3KiONNECTION OF 0 0 13 DETAIL SCALE: N.T.S.NTs 122 GROUND WIRE TO GROUND BAR 0 Z �O4SCALE: N.T.S. �O4 SCALE: N.T.S. 0 U •� ' avi lt,QFQ �F� .� 18c • BECHTEL ASSOCIATES SITE NAME. ORIENT POINT ��` �9 0� m � PROFESSIONAL CORPORATION SITE NUMBER. NYCENY0735 1 01/10/13 LTE—ISSUED FOR CONSTRUCTION AS cs RC * 4 p•= r, o .a; 1 23300 MAIN ROAD c GROUNDING NOTES & DETAILS +, +, co A UNIT OF BECHTEL CORPORATION 0 01/04/13 LTE—ISSUED FOR CONSTRUCTION AS gGS RC_c •c .w ORIENT, NY 1 1957? 5275 WESTVIEW DRIVE N0. DATE REVISIONS BY PPS y�FO �45439' ��'�'` JOB NUMBER DRAWING NUMBER REV >, L_ 'c FREDERICK, MD 21703-8386 USA ARoFESs+aNAp.v o•° = SCALE: AS NOTED DESIGNED BY: AS DRAWN BY: AS 25736-415 T3—NYCENY0735—E04 1 U aQ SIZE 22 x 34 ANSI D