Loading...
HomeMy WebLinkAbout37561-Z P gUFFpt��, Town of Southold Annex 11/26/2013 P.O.Box 1179 co54375 Main Road o 47 , Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 36621 Date: 11/26/2013 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1305 Bayview Ave, Mattituck, SCTM#: 473889 Sec/Block/Lot: 106.-6-20.4 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 9/28/2012 pursuant to which Building Permit No. 37561 dated 10/4/2012 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels on an existing one family dwelling as applied for. The certificate is issued to Goehringer,Gerard&Goehringer,Barbara (OWNER) of the aforesaid building. -SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 37561 12/4/12 PLUMBERS CERTIFICATION DATED Authorized Signature TOWN OF SOUTHOLD �OfFO( BUILDING DEPARTMENT ' TOWN CLERK'S OFFICE oy . � ,{ SOUTHOLD, NY o ., BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 37561 Date: 10/4/2012 Permission is hereby granted to: Goehringer, Gerard & Goehringer, Barbara PO BOX 812 Mattituck, NY 11952 To: construct an electric Solar Panel system to an existing dwelling as applied for At premises located at: 1305 Bayview Ave, Mattituck SCTM # 473889 Sec/Block/Lot# 106.-6-20.4 Pursuant to application dated 9/28/2012 and approved by the Building Inspector. To expire on 4/5/2014. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $50.00 CO -ALTERATION TO DWELLING $50.00 Total: $100.00 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDINC DEPARTMENT TOWN HAAL.L 71 5-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be.filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use:—, L Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept of water supply and sewerage-disposal(S-9 form). 3. Approvafof'electrical installation_from Board of Fire Underwriters. 4. 'Sworn statement4om plumber certifying that thesolder used in system contains less than 2/10 of 1%lead. 5. Commercial building;industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. t'Pl 6. Submianning Board Approval-of completed-site plan requirements. For existing buildings`(prior`to APril 9, 1957)`nOn-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey ofproperty showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building lnspector'shall state the reasons therefor in writing to the applicant. C. Fees I. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00;13usinesses$50.00.- 2. Certificate of Occupancy on Pre-existing Building- $106.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 .5. Temporary Certificate of.Occupancy-Residential$15.00,Commercial$15.00 Date. New Construction: Old or Pre-existing Building: (check one) Location of Properly: House No. Street Hamlet Owner or Owners of Property: ' Suffolk CouIt ax M No 1000,'Section / `.Block Lot' Subdivision :filed Map. Lot: Permit No. Date of Permit. - Applicant: Health Dept.Approvil: Underwriters Approval: Planning Board-Approval: . Request for. Temporary.Certificate-' Final Certificate: one) . Fee Submitted: Applicant Sig e o��OF SO(/r�ol Town Hall Annex ~ Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 G roger.richertl(E town.southold.ny.us Southold,NY 11971-0959 C4UNTY,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Gerry Goehringer Address: 1305 Bayview Ave City: Mattituck St: NY Zip: 11952 Building Permit#: 37561 Section: 106 Block: 6 Lot: 20.4 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Eastern Energy Systems License No: 47657-me SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: PHOTOVOLTAIC SYSTEM, 4900 watts, 20 Conergy 245 watt panels 2-Sunny Boy 2500 inverters Notes: Inspector Signature: Date: Dec 4 2012 81-Cert Electrical Compliance Form.xls all Eastern "The Po`ver of IndependenceTM"7470 Sound Avenue ENERGY SYSTEMSMattituck, NY 11952 WVVW E2SVS_cCOM 631.779.4004 fax 631.466.5200 10/9/12 COMPLIANCE OF INSTALLATION Project Name: Goehringer Customer Name: Jerry Goehringer Installation Address: 1305 Bayview Avenue, Mattituck, NY 11952 Applicant's License: 47657-ME Systems Info: 4,900 Watt Solar PV System with 20 Conergy 245 Watt Solar Panels and 2 SMA Sunny Boy 25000S Inverters ,It has been inspected and'the electrical and mechanical work and/or equipment described above appear to have been installed in compliance with state, local and national electric code requirements. Insp.e ed by: Pradeep Mohanraj Engineer SOLAR WIND GEOTHERMAL ENERGY AUDITS DESIGN I ENGINEERING I INTEGRATION PROJECT MANAGEMENT FIELD CrXQN REPORT DATE COMMENTS FOUNDATION(1ST) 1 � 3s0 � • FOUNDATION(2ND) r.. ROUGH FRAMING& y PLUMBING M C INSULATION PER N.Y. STATE ENERGY CODE r NAL *{- ADDITIONAL COMMENTS Q-r � a � z TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631)765-9502 Survey ✓ SoutholdTown.NorthFork.net PERMIT NO. �} 7 Check a00-m Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined t� ,20_ Storm-Water Assessment Form Contact: 0411 /��� Approved ,20/ Ni�ei�-to: lblL Wo' Disapproved a/c 6@.q R Phone: Expiration ,20_1�( Building Inspector APPLICATION FOR BUILDING PERMIT Date y�q , 20 fc2 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code, housing code, and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of appl` ant or name,if a corporation) ��F7o�v�Avg, ►h .�-!v�� NCI r���a (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, enginee gene�contractor, lectrician, plumber or builder Name of owner of premises �if As on the tax roll or latest deed) If applkgntis c oration, signature of Oulygauthorized offic r illnd title of corporate o ficer)rs License No. �J /lid/) , y:w'? Plumbers License No. Electricians License No. 7�'JE Other Trade's License No. T-`A 1. Location of land on N ch proposed work will be done: House Number T Street Hamlet County Tax Map No. 1000 Section_'b6,' Block _. _(p Lot _ 0 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy 0l e —C b. Intended use and occupancy V$00mce ! erd q u CND} GxIar N a.rra 3. Nature of work(check which applicable): New Building Addition V Alteration Repair Removal Demolition Other Work 4. Estimated Cost �J,��•(� Fee (Description) (To be paid on filing this ap lication) 5. If dwelling,number of dwelling units I Number of dwelling units on each floor If garage, number of cars CAr 6. If business, commercial'or mixed occupancy, specify nature and extent of each type of use. 01A 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear .Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO ✓ O/A . 13. Will lot be re-graded? YES NO ✓ Will excess fill.be removed from premises? YES NO 14.Names of Owner of premises Gem( DO wIO�t?,1� Address I j �/u�0ld AY4, i1q Phone No. �7JI N5 9I7� Name of Architect Address Phone No Name of Contractor Cart) bra .5u�1M19EE Address D Phone No. M/ 171 4C?04 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) � """"����� SS: COUNTY Ot'�a�CrCC)l� Kelr�l �2 M being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, �r_ (S)He is the (Contractor,Agent, Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me th' o� day of be-f- 20_4,?- Notary Public gARg RA H.TANDY Signature of Applicant Notary No 101 T State Of 01 New York Qualified in Suffolk County Commission Expires 01/13/20 o � �a— Town Hall Annex 4 4 Telephone(631)765-1802 54375 Main Road • 0 oo P.O..Box 1179 roner.dchertd-to 00p6 V us Southold,NY 11971-0959 y�OUI�i`l, �•.�` WADING DEPARTMENT i TO%W OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION . i. i REQUESTED BY: 6610 §106. Date: Company Name: 6her 1S PyyJS Name: o' AlkU> -. License No.: M15. Address: -7 76 aaf GYM 9S Phone No.: . 01-719 GiJ0 I .JOBSITE fNFORMA�TIION: (*Indicates required information) *Name: i *Address: I�JD� U U`aid 47 I* hle,(, AI V g?5-p- *Cross Street: / I *Phone No.: Permit No.: Tax-Map District: 1000 Section: P0lp - Block: _ Lot: ,Q(?, *BRIEF DESCRIPTION OF WORK(Please Print Clearly) elb1a✓ oV AT(a - ao-F Moo!fJ 5+ef-o (Please Circle All That Apply) *Is job ready for inspection: Y S/ NO. Rough in Final *Do.you need a Temp Certificate: ES NO Temp Information(If needed) *Service Size: 1 Phase 3Phase 10.0 150 200 300 350 . 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION .82=Request for InspectJon Form *pF SO�jyolo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 CA Southold,NY 11971-0959 OWN, N,� BUILDING DEPARTMENT TOWN OF SOUTHOLD November 8, 2013 Gerard Goehringer PO Box 812 Mattituck, NY 11952 Re: 1305 Bayview Ave, Mattituck TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: "Note: Letter required from an architect or engineer to certify the fastening of the panels to the roof Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. (Contact your electrician) A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 411/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept BUILDING PERMIT: 37561 — Solar Panels NS83 51 1s1.tE OF PROPERTYSURA 40. oop inG ludin /o lots #Iq-21) P/O w E p r SHORE AGRES 9� 19 1 LOT MAP O. FILED JANUARY 3, .1�114 FILE No. 41 06 f S f S I TUATE: MATT I TUG K �69 p � 10 I TOWN: SOUTHOLD y yTCpj SUFFOLK '-GOUNTY, NY SURVE(ED Oq-Iq-OI s t ° P/O AMENDED II-14-01, LOT .�v-�' --- - I ° I 12-13-OI ° 22 _ \ � 5GT# IOOr�-106-6-16.2 � �- ___ - o shed o . SheQ• i p4 �� I # o /o O � 5 \ ���` I . GERTIFIED TO: o ° 4 ° 21 1 9 arep � GERARD P. GOEHRI NGER dr VeWpy Parke / I BARBARA J.. 60EHRINGER o ° 90��� 1 ° Q°° 1 /r P/O cre h (¢ y //�'�1I I LOT P/O Ici 2 o��ioo /, LOT eta^ rr` 2:2 'jv? Q2 ti , wOoa LOT I ICI---- ��.fkoo�y ' OF O�� ,a.wUae msaroetn a omaecn w o sir+a map t a U o r t bae swayers aaa to o r bwlbn ci tsars 73[:a,sut4Nisbn 1,c/N Y ewe Yuk sere Eexotbn t-om Q� a l' J���� a acpbs r?am eb wyNa or exs sws '/�/. P P * see riu a crrgNoi ere eM w,o w�ayor . _ � _ 3 i� �• .J—�' .QF �C : _ r fto�^Fee saoi s+nu t;a caroiaeree w ea win en . _ s ,cermeeoebas baaowe krarn segnrty eras en ' savoy..os prapo-ee N ouaaorca wan U.U fisting toes r Frocerca rcr e.oro x.mys wcp ///Illggg �•,(� ty ens ue.s YutSla[e Assccblla or Prcrassicry ,q, \• Lyd 51. s.• w.Nba[bns sole u a sway p qua— NOTES: o L�J o.,a oa tus eanau w tna ta�a ooa�pay 03 �� � toe oro��enslautecn nstae an o �� w ene oss dens bro tsututbn,cucuw ■ MONUMENT ebm ors,et t�msrarmb w mcebror Nstautb AREAS: J JOHN C a E �E S LA SURVEYOR t� �r AREA : 50,I18 SF OR 1.15 A6REs 6 EAST MAIN STREET N.Y.S.LIC.NO.50202 RIVERBEA.b,N.Y. 11901 GRAPHIC SCALE I"=30' 369-8288 Fax 369-8287 REF.-1\Hp server\d\PROS\01-274b.pro Roof Section A Subject roof has no more than one layer GENERAL NOTES mean roof height 25 ft Panels mounted flush to roof no higher than 6 inches above surface. • pitch 7 in/12 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT THE 11.THE OWNER SHALL SELECT ALL FINISH MATERIALS AND COLORS. roof rafter 2x6 SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE 12.THESE DRAWINGS AS INSTRUMENTS OF SERVICE ARE AND SHALL rafters spacing 16 in OC HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE PROJECT P 9 AGREE WITH SAME. FOR WHICH THEY ARE MADE IS EXECUTED OR NOT.THEY ARE_ Reflected roof rafter span 10.4 ft 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED APPROVALS, NOT TO BE USED ON ANY OTHER PROJECTS OR EXTENSIONS TO p PERMITS,CERTIFICATES OF OCCUPANCY,INSPECTION THIS PROJECT EXCEPT BY AGREEMENT W WRITING AND WITH Table R802.5.1(1)max allowable 13.3 ft APPROVALS,ETC.,FOR WORK PERFORMED FROM AGENCIES HAVING APPROPRIATE COMPENSATION TO THE ENGINEER. JURISDICTION THEREOF.IF REQUIRED. 13.CONTRACTOR SHALL PROTECT,PATCH AND REPAIRALL EXISTING WORK ADJACENT TO HIS ViORK collar tie 2x4 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND OR DAMAGED AS RESULTOF HISINOR. ALL RULES AND REGULATIONS OF THE RESPONSIBLE JURISTICTION, 14.THE SUBCONTRACTORS SPALL PRMrE ALL EQUIP&THT,TOOLS,FENCES.TRANSPORTATIONS, collar tie spacing 48 in OC 4, ALL METHODS OF CONSTRUCTION ARE TO BE CAREFULLY SAFEGUARDS.-eTC.,ASREµUtR'eD FOR THE PROPER EXECUTION OF THEIR WORK. SUPERVISED BY THE CONTRACTOR. S. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS 15.CONTRACTOR TOEFFECT AND MAINTAIN INSURANCE,LE CONTRAC-C"LIA8ILITY,LYORK!h&"S WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, COMPENSATION,COMPLETED OPERATION,ETC ADEQUATE FOR THE PURPOSES OF THISS PROJECT AND THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE ENGINEER. FURNISH PROOF OF SWE PRIOR TO COA7'I°..NCR1GIt'RF?WORK, SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND CONTINUE 16.EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAIN-M SAFETY ON THE JOB SITE DURING . WITH THE WORK,HE SHALL ASSUME ALL RESPONSIBILITY AND THE CONSTRUCTION P14ASE TO CONFLY IPATH THE REGULATIONS AND REQUIREMENTS OFTHE f\.� LIABILITY THEREFROM. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION.THIS SHALL INCLUDE,BUT ARE NOT LIMITED TO: 12 6. ALL STRUCTURAL STEEL SHALL BE A-36 AND SHALL BE PRO'JIDUIG FOR ADEQUATEAND PROPER BRACING,SAFETY RAILINGS AND SECURE FOOTINGS FORALL FABRICATED AND INSTALLED AS PER LATEST A.I.S.C. TEMPORARY SCAFFOLDING,STAIRS,ETC,AS INELLAS PERMANENT CONSTRUCTION. SPECIFICATIONS, 17.FIGUM DIMENSIONS SHALL GOVEM4.DO NOT SCALE DRAWINGS.WHERE DIMENSIONS ARE 7. ALL DRYWALL SHALL BE U.S.G.NATIONAL GYPSUM CO.W ESTABLISHED BY EXISTING CONDITIONS.EACH CONTRACTOR SHALL VERIFY EXLSTWG CONDITIONS SEE d E'T_ 1 THICK UNLESS OTHERWISE NOTED. PRIOR TO ORDERING MATERIALS AND COMMENCING WITH WORK. 8, ALL ELECTRICAL"WORK SHALL BE BOARD OF FIRE UNDERWRITERS 18.CONTRACTOR SHALL COORDINATE ALL PHASES OR WORK N7TN THE REQUIRED PARTIES.ALL r APPROVED AND IN ACCORDANCE WITH N.E.C.&NYS PHASES OF ADJACENT FACILITIES OPERATIONS STALL BE MAINTAINED DURING CONSTRUCTION. CODES& REGULATIONS.9.ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN CONTRACTOR SHALL KEEP SITE FREE OF CONSTRUCTION DEBRIS AND KEEP SITE FULLY ACCESSIBLE —� CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S TO THE PUBLIC DURING HOURS OF OPERATION. \ CERTIFICATION OF THESE PLANS. 19.CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS Y410RK FROM THE SITE AND DISPOSE OF SEE ET. 1 10.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING. IN A LEGAL MANNER ON AWEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. ROOF Cross Section FITTING OR PATCHING REQUIRED TO COMPLETE THE WORK OR TO 20.AT THE COMPLETION OF WORK,THE SITE IS TO BE CLEARED OF ALL DEBRIS AND EXCESS MAKE ITS PARTS FIT TOGETHER PROPERLY, MATERIALS.THE FACILITY 13 TO BE LEFT BROOM CLEAN AND YJORK IS TO BE COMPLETED TO N.T.S THE TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF FINAL PAYMENT. APPROVED AS NOTED CONDUIT DATE' 45 !o ( >' 14 FROM ARRAY -g �' �y - INNINh �� `. �loTtE`( bur" �E 6sR7!>YF;, f hT INVERTER INVERTER 7f55-1802 8 AM TO 4 PM FOR "TNE rOLLOVViNU IN; F'. ( TIONS: 1. FOUNDA T 10N rI METER ER DC FOR POURED CONCRETE UIRED WIRING GUTTER 2. ROUGH-FRAM r.; PLUMBING, Y DISCONNECT L CTRICAL 81 CAUL STRAPPING, _ KING ° �� � 3. INSULATION E SERVICE 1 � NC 4 � FINAL CONSTRUCTION .� Y Et, � P�l - f�1 TON &ELECTRICAL I MUST BE COM I AC AC. D �n ' p ALL CONSTRUCTION SHALL MEET THE yRaft (FWIREMENTS +OF THE CODES OF NEW rvliL3C3crTTp ',.,,,., �,, �°�� I R I5`�=; F.= �� I I �IV �� CE RTI F I C:4 Y f�R STATE. NOT RESPONSIBLE FOR TYPICAL I CAL RISER D IAG IMAM T DESIGN OR CONSTRUCTION ERRORS. 1 .r,.'�` �� ,«✓'`� .a i �ae>7 U f `..Qa poi'' E S End 60M h ��°°t , RISER DIAGRAM SHOWN FOR REFERENCE ELE�+TRILF�L INSPECTION 5B try Revision 5 SalcrA+^-:sni Rod r 11 2 � = To my best belief and information the Work in this document is accurate, con orms wit t Revision arT, ca 1�t R governing codes applicable at the time of submission, conforms with reasonable standards Revision 3 TYPICAL CONNECTION DETAIL 1 ALL ROOF PENETRATIONS ARE TO BE SEALED of practice,with the view to the safeguarding of life, health, property and public welfare, Revision 2 PV PANEL WITH SIKAFLEX OR EQUIVALENT SEALANT Section: 106 and is the responsibility of the licensee. Revision 1 Professional Seal: as per ASCE7, Method 1: A(fig 6-2) 1.35 1 (table 6-1) 1 Block: 6 PACIFICO ENGINEERING PC P Net =A Kzt l P ner30 (eq 6-2) Kt(sec 6.5.7) 1 Pnet30(fig 6-3) -25.9 Lot: 20.4 OF N E K/ 7oo Lakeland Ave, Suite 2.13, Bohemia, NY 11716 Maximim y0 Tel: 632- ?88-0000 Fax: 632-382.-82.36 Email: .vLgivteer@ acifieoengiv►eeriing.eom CLIMACTIC AND Ground Wind Speed, Live load, N PAC/,c s point pullout _ fastener �P Q /0 GEOGRAPHIC DESIGN Category Snow Load, 3 sec gust, pnet30 per Fastener type p CRITERIA Pg mph ASCE 7,psf load,lb spa ails,ing inon9 � CC Gerry GoeG►riv►yer Roof Section A C 20 120 35 377 5/16"dia screw, 3-1/2"length •48 �^ ! /Z 13os 13ayview Ave, Mattituck, NY 12952 LLJ PROPOSED SOLAR ENERGY WSTALLATION vr°wry oncnpc°�: �O 0661 B?- GENERAL NOTES, ROOF SECTION, DATA, DETAILS AND SPECS Ralp aL I£f� o � 1 Ineer Mt. salc NY 0 44306 09/25/22 AS NOTED J. of Z I� 3 PROPOSED SOLAR INSTALLATION FLUSH MOUNTED r 18" CLEAR PATH / SOLAR SOLAR SOLAR SOLAR SOLAR SOLAR SOLAR— SOLAR SOLAR— CS6P-245 CS6P-245- CS6P-245 C66P-245- C86P-245- CS6P-245- CSGP-245- :CS6P-245- CS6P-245 V 0 CA ADON CA A CANA LAN CA AD CANADIAN CA DIAN CANADIAN G NADIA CANADIA CA DI CANAD9IA SOLAR SOLAR SOLAR SOLAR SOLAR SOLAR SOLAR SOLAR— SOLAR SOLAR— SOLAR Y CS6P-245 CS6P-245 CS6P-245 CS6P-245 CS6P-245 CS6P-245 CS6P-245 CS6P-245 CS6P-245 CS6P-245 CS6P-245 L� DISCONNECT LOCATED �'01-9!1 Ile IN FRONT O OF HOUSE ON EAST SIDE ROOF LAYOUT Professional Seal: PACIFIC0 ENGINEERING PC PV Panel OF NEW Y 700 Lakeland Ave, Suite 2.0, Bohemia, NY 11716 A !�, 0 Tel: 631-1788-0000 Fax: 631-382-82 lnn 36 Email: engineer@ acificoengineering.co eN PACIciCO�'� Soa.P; row 5 Canadian Solar Uj Q PANEL: CS6P-245 Gerry Goehringer QTY: 20 r w 1305 Sayview Ave, Mattituck, NY 21952 _ z P.;�o S —002.00 LENGTH: 64.5 in 0 xaa�a C? PROPOSED SOLAR ENERGY INSTALLATION I have reviewed the roofing structure at the subject address.The structure can support the additional weight 1- �� o,,,,,,;,g o—pn— of the roof mounted system.The units are to be installed in accordance with the manufacturer's installation WIDTH: 38.7 in C�` 066182 �, DATA, DETAILS AND SPECS p GENERAL NOTES, ROOF SECTION, instructions.I have determined that the installation will meet the requirements of the 2010 NYS Building Ral ro meer oacr. s�ie: Code,and ASCE7-05 when installed in accordance with the manufacturer's instructions. WATTS- 4900 NY 0 44306 09/ZS/12 AS NOTED 2 Of 2