Loading...
HomeMy WebLinkAbout37987-Z gUFFpj,�c Town of Southold Annex 9/5/2013 ®Gy P.O.Box 1179 cm y a 54375 Main Road o Southold,New York 11971 4,1 CERTIFICATE OF OCCUPANCY No: 36489 Date: 9/5/2013 THIS CERTIFIES that the building RESIDENTIAL ADDITION Location of Property: 1435 Ackerly Pd Ln, Southold, SCTM#: 473889 Sec/Block/Lot: 69.-5-7.3 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 4/16/2013 pursuant to which Building Permit No. 37987 dated 4/30/2013 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: construct an addition to an existing single family dwelling as applied for. The certificate is issued to Becker,Brian (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 37987 6/17/13 & 8/29/13 PLUMBERS CERTIFICATION DATED Autho d Sig ature ��5�FF ola TOWN OF SOUTHOLD BUILDING DEPARTMENT cn TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 37987 Date: 4/30/2013 Permission is hereby granted to: Becker, Brian 1435 Ackerly Pond Ln Southold, NY 11971 To: construct an addition to an existing single family dwelling as applied for, At premises located at: 1435 Ackerly Pd Ln, Southold SCTM # 473889 Sec/Block/Lot# 69.-5-7.3 Pursuant to application dated 4/16/2013 and approved by the Building Inspector. To expire on 10/30/2014. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $462.00 CO -ADDITION TO DWELLING $50.00 Total: $512.00 Building Inspector r Form No.6 1 TOWN OF SOUTHOLD � BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: I. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing"land uses: 1. Accurate survey of.property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00, Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00, Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 Updated Certificate of Occupancy- $50.00 .5. Temporary Certificate of Occupancy -Residential $15.00, Commercial $15.00 Date. - New Construction: Old or Pre-existing Building: (check one) �Q Location of Property: J�� t�G!C �� L/ pyt..7 House No. Street Hamlet Owner or Owners of Property: p. Suffolk County Tax Map No 1000,Section `p /� Block S Lot Subdivision q Filed Map. Lot: Permit No. -! �� Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: V (check one) Fee Submitted: $ Applicant Signature pF SO(/j�,ol Town Hall Annex Telephone(631)765-1802 54375 Main Road . Fax(631)765-9502 P.O.Box 1179 c roger.riche rtl-town.southo Id.ny.us Southold,NY 11971-0959 o�yCOU ,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Brian Becker Address: 1435 Ackerly Pond Ln City: Southold St: NY Zip: 11971 Building Permit#: 37987 Section: 69 Block: 5 Lot: 7.3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: DBA: Peconic Electric License No: 43457-me SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor X 1st Floor X Pool New Renovation 2nd Floor Hot Tub Addition X Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 11 Ceiling Fixtures 2 HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures 4 Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 119 Twist Lock Exit Fixtures TVSS Other Equipment: 2-paddle fans Notes: Inspector Signature: Date: Aug 29 2013 81-Cert Electrical Compliance Form.xls suEFol� Town Hall Annex p� CQ�� Telephone(631) 765-1802 54375 Main Road o Fax (631) 765-9502 P.O. Box 1179 w� • Southold, NY 11971-0959 y�jQd �•a4�' roger.richert(a�-town.southold.ny.us BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Brian Becker Address: 1435 Ackerly Pond La City:Southold St: NY Zip: 11971 Building Permit#: 37987 Section: 69 Block: 5 Lot: 7.3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: SBA: Peconic Electric License No: 43457-me SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only X Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph 200a Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200a A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect 200a Switches Twist Lock Exit Fixtures TVSS Other Equipment: service only--200a underground Service Notes: Inspector Signature: Date: June 17 2013 Electrical Certificate.xls .2,�7 pE SO(/l • �o �'YOOUNT 1l TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION FOUNDATION 1ST [ ] ROUGH PLRG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL . [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (F REMARKS: DATE oZl ll,3 INSPECTOR O i of soa �yooUNTI,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUN TION 1ST [ ] ROUGH PLBG. [ ] F NDATION 2ND [ ] INSULATION FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: CIJI,-A Xn, DATE ! INSPECTOR SOUTy�� . �o ���'�OOUN►`I,��Q TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION, [ ] FOUNDATION 1ST [ ] R H PLBG. [ ] FOUNDATION 2ND INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY " [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICA ) REMARKS: . ; DATE ✓r INSPECTOR SOUI�o� �ycouHr+,a�' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: DATE INSPECTOR pE SO�ryo�o TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH L13G. [ ] FOUNDATION 2ND [ ] 1 LATION [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: DATE ! INSPECTOR pF SOUlyolo Comm,N TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) �}-KECTRICAL (FINAL) REMARKS: DATE ` l3 INSPECTOR f FIELD pLWECTION REPORT DATE COMMENT FOUNDATION(1ST) 00 FOUNDATION(ZND) o .�' (3'1 ROUGH FRAMING& y PLUMBING IN$UL•ATION PER N.Y. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS n1 ty TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL:(631)765-1802 Planning Board approval FAX:(631)765-9502 , Survey SoutholdTown.NorthFork.net PERMIT NO. 3 71 l� 7 Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined ,20 1-3 Storm-Water Assessment Form Contact: 1 Approved 20�� Mail to: Disapproved a/c Phone: Expiration 0,20 f Building Inspector APPLICATION FOR BUILDING PERMIT Date 20 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) (Mailing address of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder D 5 i E Name of owner of premises \A. v QNI (J/--a U) (As on the tax roll or latest deed) yn If applicant is a corporation,signature of duly authorized officer APR 16 [0 (Name and title of corporate officer) BLDG.DEPT. Builders License No. TOWN OF SOUTHOLD Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on wh;,ch proposed work d1 b don : u 3� P-c Vey v� ovtr� �,r�c House Number Street a ,,Hamlet County Tax Map No. 1000 Section � d Block �/ Lot �. Subdivision Filed Map No. Lot ' r 2. State existing use and occupancy of prem and intend use and occupancy of roposed construction: iss a. Existing use and occupancy ,n!1 le A/*L( L"1A b. Intended use and occupancy ;!2-- Le— w (h BY- 3. Nature of work(check which applicable):New Building Addition—7�-'—_Alteration Repair Removal Demolition Other Work f� � }/ 4. Estimated Cost � L/� � Fee (Description) (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures,if any:Front 7 S —0 k Rear a Depth VO Height a', '--& f — Number of Stories r 4 Dimensions of saMe structure with alterations or addition : Front Rear Depl lD " Height o?'7 Number of Stories 67 8. Dimensions of entire new construction:Front Rear / D Depth Height /& " V Number of Stories 9. Size of lot:Front a30 ��� Rear a30 Depth 10.Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated J,'g4 12.Does proposed construction violate any zoning law,ordinance or regulation?YES_NO& \! 13.Will lot be re-graded?YES-X NO Will excess fill be removed from premises?YES_NO�C 14.Names of Owner of premises G2 yv4x Address S v 11�0 1J Phone No. Name of Architect C(2O11,Y\- Address --6ktA I S. Phone No Name of Contractor Address Phone No. 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO,,�Q *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY V�REQUIRED. b.Is this property within 300 feet of a tidal wetland?*YES NO *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO) *IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF It km4 tit being duly sworn,deposes and says that(s)he is the applicant (Name of individual igning contract)above named, ° �� (S)He is the De Slnjl�wr (Contractor,Agent,LJorporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me thi day of 20 CKI TUTH otary Public State of New York Notary Pub is QU21 in Suffolk County Signa re of A h ant €1 A U Commission Expires July 28 2 Town Hail A,�uex T1-kj 6z6 f,631}765-1802 5075 Main R*a d g p.0.)Box 1179 Southold,NY 11971-0959 ; . . AP BUILDING DEPAR'BENT' QFkS+t3►T�f'H07�. 6LDG. DEPT, Ri A r . TDWNOF SDUTHDLD� dmp TGaT#APPL : C REQUESTED BY: Company Name: -G�avr�r Name: Jul e`r License No.: -T ,r 7 /f/J Address: �G) • �3t� .•�. '= rrf %9 //Ind Phone No.: / f � Q' .. J4BSITE INFURMATFON-'�''hdic ;.r f . 11i fiat )... *Name: iA Cam. Address: 3 6—C •L.. 'Cross Street: N *Phone No.. Permit No. >JA X . �3. Tax Map'C)isttict: 'I OQO. : . Section: Lot: *BRIEF �DESCRIPTION.OP.- R-K�('Pteetse Pft. , Cl y - (Ple"a Circle All That:.:P►WW y. � *Is job ready for inspection Y Rotljf ln.: Final *Do you need a Temp Cercate: . 115'!' p Temp Information *Service Size: 1 Phase. 3Phase 100 .. .160. :300• :350 400. Other *New Service: Re-wrinect Underground. Number-of Mans :.:. art0e:of Service Overhead Additional Information: PA1AANLIE�ii1Tf APPLI :AIOIV . __. 82-Request'for Inspection Form �� �� Town Hall Annex Telephone.(631)7965--11802 54375 Main Road ; a 3 SOU hOld.n .us P.O.Box 1179 T�@r faChErl _IO n V Southold,W 11971-0959 2S" BUILDIAIG:DEPARTWNT J3 ,5 of sox> d APPL[M ON FORw. �LEC' IOi�L.INSPECTION REQUESTED BY: Rate . l t3 Company Name: .C` . ,J C Name: License No.: y ,5-`l. Address: Phone No.: L3 ,� Z$-p'. J. JOBSITE INFORMATION: (*lr3dlcat ratllr ` nfdrmaorl) *Name: n k ..1 *Address: Lf *Cross Street: *Phone No.: f j Permit No.. :37 . q � Tax Map District: 01, Sects©n1 Flock Lot: -- _- *BRIEF DESCRIPTION OF gIVQil�(Please Pr�nt:_Glearly) (Please Circle AR47hOt Apply)` `� 1 :. *Is job ready for inspection:. XES NO Rough In Final *Do you need a Temp Ceaficte - YES f0 Temp Information(lf n�eacled) *Service Size: 1 Phase Phase 100 150 20O 300'. 350. . 400. Other *New Service: Re-connect Undergr+otnd Number:of Meters Change of Servico Overhead Additional Information: ' " PAYMENT QUt V.. APPLICATION �►�S� — l� *l���.C� lJ /l A bo 82-Request for Inspection Form TOWN OF SOUTHOLD PROPERTY RECORD CARD OWNER _ _ STREET VILLAGE DIST. SUB. LOT -- ; k-e no, ACR. W_ REMARKS 'c' f'''(/ = r i � - -� /I Z F ?� /--1 am n �� � ; t 7 / r TYPE OF BLD. �Ir tom'-,1 . ' /a a -�t 3ip ` PROP. CLASS LAND IMP. TOTAL DATE I. 2- 2 noo:�r ! q goo ` 7-f 0® '2- FRONTAGE ON WATER TILLABLE FRONTAGE ON ROAD WOODLAND DEPTH MEADOWLAND BULKHEAD HOUSE/LOT I f C� TOTAL ' . (6 6 f NOON ■■■®■!■■■■■■iG7■■■■0■■■.�� ■■■■■NON■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■ MMMMMMMMMMMMMEMMMMMMMMMMMEM ■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■N■■■■■■■■■■■■■■N■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■ _ P = ■N■■N■■MvQHN■w■■E■■■■E■■■■■■ ■■■EN■F■MMMUM mom■NEON NEEEN■ • - �� � � :: - _ - . :— NOON■�M■A■Q�l�■■■■■■■■■■■■■■ 1A _ �I NOON 0■! ■11■■■■■■■■■■■NONE■■■ _ .� Y b Jl - NOON■E■■IiOOiiO■■■■■■■■■■■■■■ a �� , `+ar'Z� ' ' V. f5�'1H'-t'�` 'Y...�+M z ` .-•. } h NOON_■�_■■�■■■�■■■■■■■■■■■■■■ wr-M `�"..rs,. �` KyP++" ;'i y,'.E-'' '"•f�- +. f'.FP'1M° cazJ rL �'S.Ya4' .;, Basement WL, SLAB Ext. Walls Interior Finish Fire Place Dormer 1x 1. �4 ♦ - h ,�V� ' ■OOO■■■■■■■■■■■■NEE■■■■■■■■ `'*"d�.+;t7G S• ,, z^ 'G.''`i7s'a F}y +4',+'c�'. ,^.,ar,,,c+. �" H� i.:a"Y.'r-0.- .0 y.w`r+ ai""' ���r .'�y�:�r��'iL .si� ,,,3.-S�' t c n.u�1C-?•ly2'�p • nxt-.-s-}mat._.-, i ,r^k i y, �-, r ;,y.,',y ���F.a✓ 4 ,s�`+,yn��,c'`��hYP� 1;3*r+r �3-r•t 'ti'- S tr 5rr2 ■■■■■■■■■■■■■■■■■E■■■■E■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■ .. , o .. n Outlook - scottboger@hotmail.com Page 1 of 1 New Reply Delete Archive Junk Sweep Move to Categories scott boger Search email (No Subject) Eduardo Folders � Eduardo(ill - ••• Inbox 22 To:scottbog Junk 2 1 attachment k7 Drafts 31 Sent �r Deleted 95 New folder Quick views View slide show(1) Do Sent from my Whone V Content from©v O 2013 Microsoft Terms ®PdfiaRpicrbeoRopdrerm!fngRsiw4tlnitelD&atep)ers English(United States) Learn more I Turn off https://bayl67.mail.live.com/default.aspx?id=64855 6/29/2013 Outlook - scottboger(&,hotmail.com Page 1 of 1 New Reply Delete Archive Junk Sweep Move to Categories Scott boger Search email (No Subject) Eduardo Folders Eduardo(ill To:scottbog Inbox 16 k7 Junk 2 1 attachment Drafts 31 Sent Deleted 95 New folder Quick views View slide show(1) Do Sent from my Whone V Content from©w 0 2013 Microsoft Terms (OFdiI&I) licOeMopdrorm�EngHsiv4tlnited6tatep)ers English(United States) Learn more I Turn off https:Hbayl67.mail.live.com/mail/ 6/29/2013 Outlook - scottboger@hotmail.com Page 1 of 1 New Reply Delete Archive Junk Sweep Move to Categories scott boger Search email (No Subject) Eduardo Folders Eduardo(ill •• Inbox 21 To:scottbog k? Junk 2 1 attachment Drafts 31 Sent Deleted 95 New folder A! Quick views View slide show(1) Do Sent from my Whone l� Content from M v O 2013 Microsoft Terms ®FR@kttpicrbeuNopdierm¢ngHsiw4tlnited&atepkrs English(United States) Learn more I Turn off https:/Ibay167.mail.live.com/default.aspx?id=64855 6/29/2013 *pF SO!/ryol Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 �e Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD August 16, 2013 Brian Becker 1435 Ackerly Pond Ln Southold, NY 11971 TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: Application for Certificate of Occupancy. (Enclosed) &Klectrical Underwriters Certificate. (contact your electrician) A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept BUILDING PERMIT: 37987 — Residential Addition e SUFFOLK COLT ;y�.s'�;'ARTMENT OF HEALTH SERVICES � �0 FOR APP gV#;,;_OF CONSTRUCTION ONLY ° ��'6• sue' DATE RIO-94-0102 �Sosl��� REF. No. `��- _ _ems. h� s.goZ ® APPROVED bt so C L-IJ 7. -1, A Fr NAM taom ,�° 2 :' 00 - 2 /i v \ Spa �� �, i ••\ . 43 4a. c 02, 51 "PURITAN FARMS" 18 -� f A �o -� FILE NO 9538, FILED JUL Y 19, 199�4 c�O� �r i2 t 3 �'`� 4 �i Qc Lao s; �� � ; AT SOUT`HOLD TOWN O�O��+SQ� rLp�1�7��-�fO�.D CO? Y. RED TDB FFQ�I� VOV1�YTY� N. BR N J. BECKER `� I rrr KAREN M. BECKER Scale — 6 (.p f SUFFOLK COUNTY NATIONAL BANK CT. 1994 .00 STATE'OF NEW YORK MORTGAGE v r . ��, y2xa AGENCY Mar. 10, 1995 (O undati©n) �• Sept. 995 0inat) of NEW .AR ?EA 2.50.93 Acres ANY ALTERATION OR ADDITION TO TMS SURVEY IS A VIOLATION OF SECTION 7209 OF THE AL-W YORK STA TE,EDUCATION LAW, Fri '�• �Z U8' r' EXCEPT AS PER SECTION 7209--SUBDIVISION P- ALL CERTIFICATIONS 6'. �• �' > ::. �, WEREON ARE VALID FOR TICS MAP AND COPIES THEREOF ONLY fF SAID MAP OR COPIES BEAR THE IMPRESSED SEAL OF THE SURVEYOR WHOSE RGMrURRE APPEARS HEREON. ! am fat r the STANDARDS FOR APPROVAL SEWAGE G N.Y.S. L1C. NO. 49618 ADDITIONALLY TO COMPLY 13ffff SAID LAW THEE TERM �4LTERE�BY" -(� AND CO1 ONS. .TION OF SUBSURFACE E � MUST BE USED BY ANY AND ALL SURVEYORS UMMS A COPY DISPOSA 'AL S EMS FOR SINGLE FAMILY RESIDENCES ' OF ANOTHER SURVEYOR'S MAP. TERMS SUCH AS &M'ECTm'AnllJ and alUl c 1 ahlde the condffions set forth therein and on the 20 ORS, P.C. `BROUGHT=T0-DATE'ARE moT fN COwL64NCE WITH THE LAw: permit to to o�-Ms#uCt. P. D. 909 MAIN ROAD SOUTHOLD, N.Y. 11971 ELEVATIONS ARE REFERENCED TO AN ASSUMED DATUA ry 94-311 REScheck Software Version 4.4.4 Compliance Certificate Project Title: Becker Residence Energy Code: 2010 New York Energy Conservation Location: Suffolk County,New York Construction Type: Single Family Project Type: Addition Conditioned Floor Area: 0 ft2 Heating Degree Days: 5750 Climate Zone: 4 Permit Date: Construction Site: Owner/Agent: Designer/Contractor: Ackerly Pond Lane Nancy Dwyer Design Consulting,Inc. Southold,NY Southold,NY Compliance:Passes using UAtrade-dff Compliance: 3.7%Better Than Code Maximum UA: 568 Your UA:547 The%Better or Worse Than Code Index reflects how dose to compliance the house is based on code tradeoff rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Cavity Cont. Glazing Assembly Area or or Door UA Perimeter U-Factor Wall 1:Wood Frame,16"o.c. 736 19.0 0.0 34 Window 1:Vinyl Frame:Double Pane with Low-E 134 0.320 43 SHGC:0.00 Door 1:Glass 38 0.310 12 SHGC:0.00 Ceiling 1:Flat Ceiling or Scissor Truss 580 30.0 0.0 20 Floor 1:Slab-On-Grade:Unheated 580 7.2 438 Insulation depth:2.4' Compliance Statement: The proposed building design described here is consisten ith the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed t the 2010 Ne York Energy Conservation Construction Code requirements in REScheck Version 4.4.4 and to comply with the mandatory re l is list t ESchec Inspection Checklist. •� • Name-Title Si ature Date J OF NEW y®. C� a ®8�8221 ® SSIO%N`'-- Project Title: Becker Residence Report date: 04/17/13 Data filename: Untitled.rck Page 1 of 6 REScheck Software Version 4.4.4 Inspection Checklist Requirements: 0.0% were addressed directly in the REScheck software Text in the"Comments/Assumptions"column is provided by the user in the REScheck Requirements screen.For each requirement,the user certifies that a code requirement will be met and how that is documented,or that an exception is being claimed.Where compliance is itemized in a separate table,a reference to that table is provided. 2010 New P York Pre-inspection/Plan Review Plans Verified Field Verified` Complies? 'Comments/Assumptions EnergyValue Value 103.2 Construction drawings and }`} 0Complies ' [PR1]1 documentation sufficiently t r❑Does Not Comply demonstrates energy code { bNot Observable compliance for the building envelope. ;❑Not Applicable 103.2, ;Construction drawings and ( ❑Complies i 403.7 .documentation sufficiently ❑Does Not Comply; [PR3]1 demonstrates energy code ❑Not Observable compliance for lighting and ttt ❑Not Applicable mechanical systems.Systems serving multiple dwelling units must demonstrate compliance with the commercial code. 403.6 Heating and cooling equipment is Heating: Heating: ;❑Complies [PR2]2 ;sized per ACCA Manual S based on Btu/hr Btu/hr ❑Does Not Comply loads per ACCA Manual J or other ; Cooling: Cooling: :[]Not Observable approved methods. Btu/hr Btu/hr ;❑Not Applicable j Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Becker Residence Report date: 04/17/13 Data filename: Untitled.rck Page 2 of 6 2010 New, York Foundation Inspection Complies? Comments/Assumptions Energy. 303.2.1 Exposed foundation insulation ❑Complies [FO11]2 protection. :❑Does Not Comply :❑Not Observable ❑Not Applicable 403.8 Snow melt controls. ;❑Complies [FO12]2 ❑Does Not Comply p� �❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Ter 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Becker Residence Report date: 04/17/13 Data filename: Untitled.rck Page 3 of 6 2010 New Plans Verified Field Verified:; York Framing/Rough-In Inspection Complies? Comments/Assumptions Ener „ Value' . :' Value 9Y 402.4.4 ;Fenestration that is not site built is l J❑Complies [FR20]' listed and labeled as meeting _ ❑Does Not Comply AAMA/WDMA/CSA 101/LS.2/A440 or ;:❑Not Observable has infiltration rates per NFRC 400 `` J❑Not Applicable :that do not exceed code limits. 402.4 5 3IC-rated recessed lighting fixtures ❑Complies ; [FR16]z sealed at housing/interiorfinish and ;J❑Does Not Comply: ®� labeled to indicate&It;=2.0 cfm _ ❑Not Observable ; leakage at 75 Pa_ ,❑Not Applicable 403.2.1 ;Supply ducts in attics are insulated to ; R- ; R- ;❑Complies [FR12]1 R-8.All other ducts in unconditioned R R_ T]Does Not Comply ,spaces or outside the building U ❑Not Observable ; envelope are insulated to R-6.Not ; ❑Not Applicable applicable if all systems are ductless. 403.2.2 All joints and seams of air ducts,air + ,❑Complies [FR13]' handlers,filter boxes,and building i T]Does Not Comply: cavities used as return ducts are J❑Not Observable I ;sealed. El Not Applicable 4032.3 1 Building cavities are not used as ducts t❑Complies [FR15]3 or plenums. I❑Does Not Comply �❑Not Observable ❑Not Applicable 403:3 HVAC piping conveying fluids above ; R- R- ;❑Complies [FR17]z 1105 OF or chilled fluids below 55 OF :❑ 4 Does Not Comply .(� are insulated to R-3. ; !❑Not Observable 1 1❑Not Applicable 403.4 `Circulating service hot water pipes are; R- R- ;❑Complies ; [FR18]2 insulated to R-2. E❑Does Not Comply I ;❑Not Observable ❑Not Applicable 403.5 Automatic or gravity dampers are ❑Complies [FR19]2 1 installed on all outdoor air intakes and ❑Does Not Comply 6 exhausts. I ❑Not Observable ; i❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Becker Residence Report date: 04/17/13 Data filename: Untitled.rck Page 4 of 6 2010 New York Insulation Inspection Complies?, Comments/Assumptions Energy 303.1 jAll installed insulation labeled or ;❑Complies [IN13]2 i installed R-values provided. E❑Does Not Comply ;❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Becker Residence Report date: 04/17/13 Data filename: Untitled.rck Page 5 of 6 2010 New Plans Verified" Field Verified York Final Inspection Provisions Complies? CommentslAssumptions- Energy Value Value 402.4.2, ;Building envelope tightness verified ACH 50= ACH 50= ;❑Complies 402.4.2.1 ;by blower door test result of<7 ACH; ; :❑Does Not Comply [FI17]' at 50 Pa.This requirement may ;❑Not Observable J instead be met via visual inspection, ; :❑Not Applicable in which case verification may need to; occur during Insulation Inspection. 402.4:3 _ .i Wood-buming fireplaces have ❑Complies [FI8]2 i gasketed doors and outdoor ❑Does Not Comply U (combustion air. J❑Not Observable - JEJNot Applicable 403.2.2 Duct tightness via post-construction cfm cfm ;❑Complies [F14]' with maximum leakage of 8 cfm to :❑Does Not Comply outdoors,or 12 cfm across systems. ;❑Not Observable For rough-in tests,verification may ; �❑Not Applicable need to occur during Framing Inspection,with maximum leakage of 6 cfm across systems and 4 cfm without air handler. 403.1.1, Programmable thermostats installed f _.,❑Complies [FI9]2 {on forced air furnaces. I {❑Does Not Comply -U-) g ❑Not Observable ; 1❑Not Applicable 403.1.2 - Heat pump thermostat installed on f 40Complies [Fl10]z ;heat pumps. i '❑Does Not Comply []NotObservable ❑Not Applicable 403.4 i Circulating service hot water systems {. -'.j❑Complies [FI11]2 i have automatic or accessible manual l 4❑Does Not Comply controls. �❑Not Observable _ ;.i❑Not Applicable 403.9.1 j Readily accessible switch on heaters J❑Complies ; [F[12]3 ifor swimming pools. 3FIDoes Not Comply 63 ❑Not Observable 4 - - • ❑Not Applicable 403.9.2 ;Timer switches on pool heaters and ❑Complies j [Fl19]3 4 pumps are present. f ❑Does Not Comply \� ! ❑Not Observable } ;",❑Not Applicable 403.9.3 Heated swimming pools have a cover. 1❑Complies ; [FI20]3 Covers on pools heated over t❑Does Not Comply J . are insulated to R-12. ❑Not Observable ; 4 ❑Not Applicable 401.3 4 Compliance certificate posted. 40Complies [FI7]z ; UDoes Not Comply []Not Observable j I❑Not Applicable 303.3 Manufacturer manuals for mechanical J❑Complies ' [FI18]3 and water heating equipment have , E]Does Not Comply U been provided. ''❑Not Observable ; ! j J❑Not Applicable Additional CommentslAssumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Becker Residence Report date: 04/17/13 Data filename: Untitled.rck Page 6 of 6 2010 New York Energy Conservation Construction Code Energy Efficiency Certificate Insulation Rating R-Value Wall 19.00 Floor 7.20 Ceiling/Roof 30.00 Ductwork(unconditioned spaces): _ Door Rating U-Factor SHGC Window 0.32 Door 0.31 CoolingHeating & Heating System: Cooling System: Water Heater: Name: Date: Comments: E3ECKER RE51DENCE N CL/ O o — w ►- o 0 C\J w �t > z 0 met z w w C) (n o m NEW CONSTRUCTION CD O 0 �a Ln O co —Ll EILILI z O 0 o - Q _ EXISTING HOUSE � — W ® ® -STRUCTURE TO REMAIN,- (n ALL AREAS O A I O TW21046 TW210% FRONT ELEVATION T>=s7i'''31 U APPROVED AS NOTED z SCALE: 4" = I '-0" r DATE 3 B.P. # 7 D � � r PLUMBER, CFI�TI rICATION FEE' ��sz. BY ��- _- L1J Z NOTIFY BUILDING DEPARTNV NT ON LEAD CONT'-*hl i FEFORE ( 765-1802 8 ANI TO 4 PN1 FoR Tr� J CERTIFICATE C '_?(�GUPANCY � } FOLLOWING INSPECTIONS: 1, FOUNDATION-TWO REQUIRED C) � • SOLDER L'S t; VIA TER FOR POURED CONCRETE SUPPLY 2. ROUGH-FRAMING,PLUMBING, U O EXCEED 2110 OF 1°o LEAD. STRAPPING, ELECTRICAL&CAULKIP Q U z 3. INSULATION 4. FINAL-CONSTRUCTION &ELECTRIrl MUST BE COMPLETE FOR C.O. z z o ALI.CONSTRUCTION SHALL MEET THE s "* REQUIREMENTS OF THE CODES OF NE' — o YORK STATE. NOT RESPONSIBLE FOR W DESIGN ORCONSTRUCTION ORS. ERR F�./ RETAIN STORM WATER RUNOFF U� PURSUANT TO CHAPTER 236 OF THE TOWN CODE. PAGE: r .TkAa I NEW CONSTRUCTION cn ` 0 o m_ O O lu N 4 n w Q z z_ J W cCc� � J N � O O F- L TW21046 TW21046 TW210% TW21046 --------------- z O p p SIDE ELEVATION o SCALE: ' = I '-O" O CL 0 NEW CONSTRUCTION U z � EXISTING HOUSE L „_, z STRUCTURE TO REMAIN, ALL AREAS J v p � . Uz0 } Q U z ----- z z o U LU p PNL 1046 TW21046 TW21046 't a� a Ft Al PAGE: a a 8W BACK ELEVATION ;. 2 SCALE: 4' = I'-0" I SECTION A PROVIDE 5IMP50N PHD5 z I9-6° HOLDDOWN MT. 2) g p m oC ANCHORS AT ALL CORNERS � L — w THROUGHOUT O� C) O Z O g° DIAMETER ANCHOR BOLTS " W/ 7" MIN. DEPTH @ 48"O.C. z W/ MIN. 3"X3' WASHER @PLATE Lu o• I � o o m ° 8 POURED CONCRETE Kn FOUNDATION WALL W/ P-4"X 8" d. FTG.; PROV. 2-#4 REBAK IN FOOTING (TYPICAL ALL AREAS) o Jz DAMP PROOF PERIMETER L OF FOUNDATION WALL � J (TYPICAL ALL AREAS) L N Z Q +� O � O U 4" POURED CONCRETE — SLAB ON COMPACTED FILL I I o I I ' EXISTING SLAB TO REMAIN O ICI � 0 0 Lu ° I O EXISTING BASEMENT 2" FOAM BOARD PANELS O TO REMAIN I 2'-0" IN AROUND ENTIRE PERIMETER UN DER SLAB � a O_ 'o PROV. EPDXIED#4 STEEL I Q REBAR VERT. @ 12"O.C. u INTO EXISTING FOUNDATION V NEW 8" CONCRETE BLOCK A NEW JOISTS TO SIT CURB WALL; DRILL REBAP'. WALL� NEW WALL ABUTTING SEG110N (TYPICAL ALL AREAS) ON EXISTING SILL; THKU EXISTING SLAB BREAK THKU WALL TO FILL CELLS FOUNDATION WALL LEGEND: U RUN NEW PLUMBING Z 2"X 6"AGQ SILL PLATE EXISTING FOUNDATION _ [� K-19 INSULATION OVERTERMITESHIELD WALL TO REMAIN OVER SILL SEAL ------ WALL TO BE REMOVED Lu Z J c� 8" POURED CONCRETE GARAGE FOUNDATION t SLAB FOUNDATION WALL • TO REMAIN WITH I'-4"X 8" FOOTING z L O o NEW 2"X 8" F.J. NEW WOOD STEPS TO U z U @ I G" O.C. GARAGE Q Z z z o Lu ��Rt�F FOUNDATION PLAN PAGE: SCALE: 4" Os 22 ��' i NAILING SCHEDULE 2001 55C HIGH WIND EDITION WOOD FRAME CONSTRUCTION MANUAL JOINT DESCRIPTION NAIL QUALITY NAIL SPACING ROOF FRAMING RAFTER TO TOP PLATE TOE NAILED 8'-O'WALL:3-8d PER RAFTER UI 10'-0"WALL: -8d PER METER Z CEILING JOIST TO TOP PLATE TOE NAILED 8'-O"WALL:3-8d PERJOIST 10'-O"WALL:4-8d PERJOIST CEILING JOIST TO PARALLEL RAFTER FACE NAILED SEE TABLE 3.7 EACH LAP CEILING JOIST LAPS OVER PARTITIONS FACE NAILED SEE TABLE 3.7 EACH LAP COLLAR TIE TO RAFTER FACE NAILED SEE TABLE 3.4 PEKTIE BLOCKING TO RAFTER TOE NAILED 2-8d EACH END A+ RIM BOARD TO RAFTER END NAILED 2-1 Gd EACH END m Z -- ILL WALL FRAMING O O O TOP PLATE TO TOP PLATE FACE NAILED 2-1 Gd PER FOOT (� z TOP PLATES AT INTERSECTIONS FACE NAILED 4-1 Gd JOINTS-EACH SIDE EX 1 ST I N G H O UI S E LLj Q z STUD STUD FACE NAILED 2 1 O/C STRUCTURE TO REMAIN,HEADERR I TO HEADER FACE NAILED 6d I G'O/C ALONG EDGES TOP OR BOTTOM PLATE TO STUD END NAILED 2-1 Gd PER 2X4 STUD ALL AREAS 3-IGd PEP.2XG STUD 2"X 1 2" RIDGE W/ U' BOTTOM PLATE TO FLOORJOIST, 4-1Gd PER 2X8STUD 51MP50N C520 CONNECTOR z LU BANDJOIST,END JOIST.OR BLOCKING FACE NAILED 2-1 Gd •— PER FOOT (TYP. ALL RAFTERS) J w FLOOR FRAMING Q (J) C m JOIST TO SILL.TOP PLATE.OR GIRDER TOE NAILED 4-8d PEKJOIST VERIFY ROOF PITCH IN ARCHITECTURAL ASPHALT BRIDGING TO J015T TOE NAILED 2-8d EACH END FIELD ROOFING WITH 1 5# FELT BLOCKING TO JOIST TOE NAILED 2-8d EACH END 12 OVER 81 CDX PLYWOOD BLOCKING TO SILL OR TOP PLATE TOE NAILED 3-1 Gd EACH BLOCK � 4 8 LEDGER STRIP TO BEAM FACE NAILED 3-1 GdEACH JOIST WITH ICE *WEATHER SHIELD JOIST ON LEDGER TO BEAM TOE NAILED 3-8d PER JOIST Q.C, @ PERIMETERS VALLEYS, BAND JOIST TO JOIST END NAILED 3-IGd PER JOIST n \6� 51MP50N H7 BAND JOIST TO SILL OR TOP PLATE TOE NAILED 2-1 Gd PER FOOT 2`x \Oa�,fL• V CONNECTOR ROOF SHEATHING L" FASCIA AND SOFFIT; MATCH 5TRUCTURAL PANELS 2-2 C.B. TH RU U 4'PMETEK EDGE ZONE- IG'O/C-G'AT PANEL EDGES C.T. 4 R.R. (TYPICAL TO EXISTING HOUSE FRONT EPJ L 8d AND AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD BOTH ENDS) 2"X I O" C.J./C.T. 16"O.G. } INTERIOR ZONE- IG"O/C-G"AT PANEL EDGES AND 12"AT N @ R-30 INSULATION � p 8d INTERMEDIATE SUPPORTS IN THE PANEL FIELD (p "a- z O FOR ROOF SHEATHING WITHIN 4'-O"OF THE PERIMETER EDGE OF THE ROOF.INCLUDING 4'-0"ON EACH SIDE OF THE ROOF PEAK.THE 4'-0'PERIMETER — 3- 2"X 8" HEADERS; z �_ EDGE ZONE ATTACHMENT REQUIREMENTS SHALL BE USED. PROVIDE SIMPSON C520 CEILING SHEATHING III Ln ff STRAPPING ABOVE All NEW GYPSUM WALLBOARD 5d GOOLEP.S 7"EDGE/10'FIELD 2 GYPSUM BOARD C _u TYPICAL ALL AREAS WINDOWS EXTERIOR DOORS -'t o U WALL SHEATHING cfl — (S) (f) STRUCTURAL PANELS 811 4'EDGE ZONE- I G"O/C-G"AT PANEL EDGES AND 1 2"AT BEDROOM FAMILY ROOM INTERMEDIATE SUPPORTS IN THE PANEL FIELD b 2"X G" STUD FRAME EXTERIOR 8d INTERIORZONE- I G'O/C-G'AT PANEL EDGES AND 1 2"AT WALL @ I G" O.C. W/ R-19 INSULATION INTERMEDIATE SUPPORTS IN THE PANEL FIELD ip L" CDX PLYWOOD SHEATHING FIBERBOARD PANELS 7/16" Gd 3"EDGE/G"FIELD 2 X 4 INTERIOR 2 25/32' 8d 3"EDGE/G'FIELD STUD PARTITION NOTE: 1D W1 TYVEK' HOUSE WRAP;51DINGTO GYPSUM WALLBOARD 5d COOLERS 7"EDGE/10'FIELD TO MATCH EXISTING ON HOUSE 8d 4'EDGEZONE- IG"O/C-G"AT PANEL EDGES AND 12"AT ALIGN FINISH FLOORHEIGHTS z HAP.DBOARD INTERMEDIATE SUPPORTS IN THE PANEL FIELD NEW WITH EXISTING SLAB 2"X G"ACQ SILL PLATE O 8d INTEROP.ZONE- i G'O/C-G"AT PANEL EDGES AND 1 2"AT VAPOR/MOISTURE INTERMEDIATE SUPPORTS IN THE PANEL FIELD OVER TERIMITE SHEILD BARRIER t FINISHED FLOOR OVER SILL SEAL; FLOOR sHEAmE S PROVIDE 51MP50N C520 Q STRUCTURAL PANELS- I'ORLE55 8d G"EDGE/ 12"FIELD 4" P. CONC. SLAB ON COMPACTED FIl1 W/ LPT4 CONNECTORS Q Nailing requirements are based on wall sheathing nailed G Inches O.C.at the panel edge. If wall sheathing Is nailed 3 Inches O.G.at the panel edge to obtain I� 2" FOAM BOARD PANELS Q higher shear capacities,nailing requirements for structural members shall be doubled,or alternate connectors,such as shear plates•shall be used to maintain the U N EXCAVATED 2'-0" IN AROUND ENTIRE 51, DIAM EfER ANCHOR BOLTS load path. PERIMETER UNDER SLAB b a NEW 8" POURED CONCRETE m W/ 7" MIN. DEPTH @ 48"O.C. Q • When wall sheathing is continuous over connected members,the tabulated number of nails shall be permitted to be reduced to I-1 Gd nail per foot. FOUNDATION WALL W/ W/ MIN. 3"X3N I" WASHER PLATE W • Corrosion resistant 1 1 gage roofingnails and 16 gage staples are remitted.check IBC for addiG—'l re umements. 8 @ I'-4"X 8" d. FTG.; PROV. 2-#4 REBAR IN FOOTING (TYPICAL ALL AREAS) O D— DE51GN LOAD CALCULATIONS O BUILDING SECTION "ALL MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS(lbsf) G- RAFTER SCALE: 111 = 1 1-011 EXTERIOR BALCONIES GO NOTCHED RAFTER DECKS 40 RAFTER RIDGE RAFTER ATTICS WITHOUT STORAGE 30 RIDGE TOP PLATE _0 TOP PLATE ATTICS WITH STORAGE 40 WALL STUD WALL STUD ROOMS(OTHER THAN SLEEPING ROOMS) 40 SLEEPING ROOMS 30 TYPICAL RIDGE TO RAFTER STRAPPING TYPICAL RIDGE BEAM TO RAFTER STRAPPING TYPICAL RAFTER TO WALL STUD CONNECTION ALTERNATIVE RAFTER TO WALL STUD CONNECTION CRITERIA FOR CALCULATION OF DEAD LOAD ACTUAL WEIGHTS OF MATERIALS REFERENCED TO A.I.A. GENERAL WIND PROTECTION CONNECTION NOTES ARCHITECTURAL GRAPHIC STANDARDS U 2ND.FLOOR WALL STUD 0 KING STUDS Adapted from Standard for Hurricane Resistant Residential Construction; 55TD DOP I 0-99 and 2001 SBC High Wind Edition Wood Frame Construction SNOW sDBFLooR z WOOD JOIST WOOD JOIST 2ND.FLUBFLO PLATE CRIPPLE STUD Fasteners and Connectors for Wood Frame Construction ^ BLOCKING JOIST HANGER RIM GROUND SNOW LOAD 45 lbs.BOARD HEADER - ^ M GIRDERMEADER IST.FLOOR TOP PLATES JACK STUDS I . A continuous load path between footings, foundations walls, floors, studs and �/ V Ln WOOD GIRDER WOODJOIST roof framing shall be provided. SEISMIC W Z I ST FLOOR WALL STUD DESIGN CATEGORY B F— ' JOIST FRAMING OVER WOOD GIRDER JOIST FRAMING FUJSH WITH GIRDER/HEADER TYPICAL HEADER CONNECTION 2. Approved connectors, anchors and other fastening devices not Included in J m the Standard Building Code, Table 230G. I shall be Installed in accordance with Q D WIND ,^ TYPICAL MULTI-STORY CONNECTIONS manufacturer's recommendations. WIND SPEED 1120 mph jv J METAL HOLD- 3. Metal plates, connectors, screws, bolts, and nails exposed directly to the EXPOSURE CATEGORY B ( ` z WAIL STUD } �l BOTTOM PLATE DOWN STRAP weather or subject to salt corrosion in costal areas, shall be stainless steel or Z WALL STUD SUB FLOOR 38-16d SINKER J DOUBLE J015T NAILS AS PER 3-2"X4"WD STUDU III) BOTTOM PLATE IST.FLOOR WALL STUD MANUFACTURER �— hot dipped galvanized. Z BATHTUB @G°RNERTYP. TABLE R30I .G Q DOUBLE JOIST 'ppmo" 2°X4"SILL IST.FLOOR LOOR PLATE 4. Where windows and doors interrupt wood structural panel sheathing and z z o DOUBLE JOIST FOR NON-BEARING WALLS BOARD RIM JOIST TYP. siding, framing anchors or connectors shall be provided at the top and bottom ALLOWABLE DEFLECTION OF STRUCTURAL MEMEBERS j m!f DBL.SILL PLATE DOUBLE SILL PLATE �-••' of cripple studs, header studs, and at least one stud at each side of opening. STRUCTURAL MEMBER ALLOWABLE DEFLECTION DOUBLE JOIST FOR UNDER A BATHTUB ANCHOR BOLT (1)N4 REBAK IN FOUNDATION WALL SHEAR CONE-MIN. 12"LENGTH Rafters haven slopes reater L/I 80 LU PROVIDE 112'SPACING 30"MIN. FOUNDATION 5. Ridge straps shall be attached to each pair of opposing rafters except where Q BETWEEN OTHERHE UN STUD REBAPLENGTH WALLTVP. than 3/I 2 with no finished ceilin ANDTHE2 RALLO LNG collar ties of I xG or 2x4 lumber is located in upper third of attic space and FOR ALLOWING CONNECT CORNER STUD U2'MIN. SILL GASKET HOLDDORM INSTALLATION TO TRANSFER SHEAR 15T.FLOOR TO FOUNDATION CONNECTIONS FROM CORNER attach to each pair of rafters. attached to rafters • FASTEN WTH(2) IGd G. Uplift connectors shall be provided at each rafter bearin TERMITE SHIELD COMMON NAILS @9O.C. METAL HOLD-DOWN/UPLIFT ANCHOR p p 9 Interior walls It partitions H/180 (TOo RAPJOI�INTS) • 51DEWALL Floors lastered ceilin s L/3GO ENDWALL 7. Floor to floor hold-downs to be provided every 48, and every 16" within 4' FOUNDATION WALL All other structural memebers L/240 SHEAR WALL CORNER CONNECTION of exterior corners. Exterior walls with plaster or H/3GO SILL PLATES TO FOUNDATION ANCHORING 8. Sill Plate to Foundation Anchorage: Sill plate shall be anchored to the stucco finish PAGE: foundation with anchor bolts having a min. bolt diameter of 5/5"and 3"x 3"x Exterior walls - wind loads with U240 �f s I/8" washers. A minimum of one anchor bolt shall be provided within G to 12 CONSTRUCTION DETAILS WIND LOAD PATH CONNECTION DETAILS inches of each end of each plate. Anchor bolts shall have a minimum embedment brittle firnshes1111 104"1 NOT TO SCALE F of 7 inches in concrete/masonry foundations. Anchor bolts shall be located Exterior walls- wind loads with L/1 within 12 inches of corners and at Spacing not exceeding 4 feet on center. flexible finishes " fI � h ® $^2a � l I