Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
37753-Z
L 5/21/2013 UFFat,� Town of Southold Annex �qq� COG�a P,O.Box 1179 y 54375 Main Road o o,.� Southold,New York 11971 4f d CERTIFICATE OF OCCUPANCY No:. 36246 Date: 5/21/2013 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 1200 PRAITY LANE CUTCHOGUE, SCTM#: 473889 Sec/Block/Lot: 109.-5-26 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 3/1/2010 pursuant to which Building Permit No. 37753 dated 1/14/2013 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: BATHROOM ADDITION/ALTERATION TO AN EXISTING SINGLE FAMILY HOME AS APPLIED FOR The certificate is issued to EDWARD WANKEL&JUDITH GORDON (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 37753 05/20/213 PLUMBERS CERTIFICATION DATED A o ed Si atur �a' TOWN OF SOUTHOLD ��ggFFD(�Cody BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 37753 Date: 1/14/2013 Permission is hereby granted to: EDWARD WANKEL & JUDITH GORDON P.O. BOX 1275 CUTCHOGUE, NY 11935 To: ADDITIONS &ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR.REPLACES EXPIRED BP # 35362 At premises located at: 1200 PRAITY LANE CUTCHOGUE SCTM # 473889 Sec/Block/Lot# 109.-5-26 Pursuant to application dated 3/1/2010 and approved by the Building Inspector. To expire on 7/15/2014. Fees: PERMIT RENEWAL $75.00 CO-ADDITION TO DWELLING $50.00 Total: $125.00 Building Inspector FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT . Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 35362 Z Date MARCH 1, 2010 Permission is hereby granted to: EDWARD WANKEL & JUDITH GORDON PO BOX 1275 CUTCHOGUE,NY 11935 for ADDITIONS & ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR.REPLACES EXPIRED BP $# 29435 at premises located at 1200 PRAITY LA CUTCHOGUE County Tax Map No. 473889 Section 109 Block 0005 Lot No. 026 pursuant to application dated MARCH 1, 2010 and approved by the Building Inspector to expire on SEPTEMBER 1, 2011 . Fee $ 150 . 00 l Aut`$ori d Signature ORIGINAL Rev. 5/8/02 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 29435 Z Date MAY 28 , 2003 Permission is hereby granted to: EDWARD E WANKEL . PO BOX 1275 CUTCHOGUE,.NY 11935 for ADDITIONS AND ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR at premises located at 1200 PRAITY LA CUTCHOGUE County Tax Map No. 473889 Section 109 Block 0005 Lot No. 026 pursuant to application dated MAY 27, 2003 and approved by the Building Inspector to expire on SEPTEMBER 28, 2004 . Fee $ 150 . 00 Authorized Signature COPY Rev. 5/8/02 Form No.6 TOWN OF SOUTHOL.D. BUILDING DEPARTMENT TOWN HALL 765-1802 "PLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled In by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,,streets,and unusual natural or topographic features. 2, Final Approval from Health Dept.of water supply and sewerage-disposal(S-9 form)'.'. a. Approval of electrical 4tallation from Board©f Fire Underwriters. 4_ 'Sworn statement from plumber certifying that the solder used in system contains less than 2110 of 1% lead. . 5. Commercial building}industrial building, multiple residences and similar buildings and installations,a certificate of Code Compliance*om architect or engineer responsible for the building: 6_ Submit Planning Board Approval bf completed site plan requirements. B. For existing buildings(prior to.April 9,.1957)non-conforming uses,or buildings and °pre-existing" find uses- 1_ Accurate survey of property showing all property lines,streets,building and unusual natural or topographic at feures. 2. A properly completed application and consent to inspect signed-by the applicant. if a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C_ Fees 1. Certificate of Occupancy- New dwelling$50.00, Additions to dwelling$50.-00, Alterations to dwelling$50:00-, Swimming pool $50.00, Accessory building-$50-00, A.dditions.to accessory building$SO-00, Businesses $50.00_ 2. Certificate of Occupancy on Preexisting Building- $100.00 3. Copy of Certificate.of.Occupancy-$:25 4. Updated Certificate of Occupancy - $50-00 . 5_ Temporary Certificate of Occupancy -Residential $1.5-0%Commercial$15.00 Date. S/l-1/ao/ New Construction: Old or Pre-existing Building: ' (check one) Location of Property: � D P�41 L�N� G'Gt��i41 P 6 - Als�-? ��j rN House No. Street Hamlet Droner or Owners of Property: Z2 i IC,() j lAAJ/G 5'Z Suffolk County Tax Map No 1000., Section Block Lot Subdivision �7 Filed Map. Lot: Permit No. /53 Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Zequest for: Temporary Certificate Final Certificate: (check one) =ee Submitted: $ Applicant Signature Town Hall Annex pp��guFFO(��0� Telephone(631)765-1802 y 54375 Main Road c Fax (631) 765-9502 00 x P.O. Box 1179 - - Southold, NY 11971-0959 y�j�l �.ap! roger.richert(a)town.southol d.ny.us BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Edward Wankel Address: 1200 Praity Lane City: Cutchogue St: NY Zip: 11935 Building Permit#: - 37753 Section: 109 Block: 5 Lot: 26 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: as built DBA: License No: SITE DETAILS Office Use Only Residential x Indoor X Basement Service Only Commerical Outdoor 1st Floor x Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 2 Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures 3 CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect rl Switches 7 Twist Lock Exit Fixtures TVSS Other Equipment: 1-exhaust fan, 1-combination heat lamp / exhaust fan, 1-electric wall heater 1-hydromassage tub Notes: Inspector Signature: Date: May 20 2013 Electrical Certificate.xls Telephone(53.1)•7654802 Town IyTaI!Annex t� q �i " '6 7+5 -9502 54375 Main Road � Fax� 3'Q. P.O.Box 1179, Southold,New'York 11971.-0959 V. F ,,"A`.TisON Buildiig Permit No. (Please print) Plum,ber:—R�!,, x. (Please print) Y ceib fly that the solder used iti.the ;; .::,, ?_:.V system contains less.tban 2/10 urf 1°/o. lmd. v � •(Plum er • Sv om to be:`Iare.me this \ _ days of ��� 20�_ Notary Public, Counts' ALICIA WALKER Notary Public State of New York No.OIWA6153064 Qualified in Suffolk County Commission Expires Sept.25,an^ 765-1802 BUILDING DEPT. INSPECTION [ "FOUNDATION iST [ ] ROUGH PLBG. [ ' FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY REMARKS: DATE INSPECTOR 76!i-1802 BUILDING DEFT. INSPECTION [ ] FOUNDATION iST [ ] ROUGH PLBG. [ ] F NDATION 2ND [ ] INSULATION [ FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY REMARKS: �i�.-2 DATE �� `� le,3 INSPECTOR 765-3802 BUILDING DEFT. INSPECTION [ ] FOUNDATION iST [ RO H PLBG. [ ] FOUNDATION 2ND [ INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY REMARKS: DATE INSPECTOR �� OF SOUIyo� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTIO [ ] FOUNDATION 1ST [ ] ROUG LEIG. [ ] FOUNDATION 2ND [ ] I LATION [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: c d DATEr1l7ki INSPECTOR OE SO!/ly�� /) 1y00UNVI � l�l TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH.PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) bA ELECTRICAL (FINAL) REMARKS: DATE kk-17, INSPECTOR FIELD-INSPECTION REPORT. . DATE CONIlYIENTS - V 4r FOUNDATION(1ST) FOUNDATION(ZND) 3 o ROUGH FRAM3NG& PLUMBING-3 J INSULATION PER N.Y. � y STATE ENERGY CODE e. f FINAL, ADDITIONAL COMMENTS 12 _ Z. -- m H o �. . M TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING,DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 3 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 - Survey www. northfork.net/Southold/ PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees Examined 2� ,20 Contact: Approved ,20__3 Mail to: Disapproved c l Phone: Expiration / 20 r in spector " Z 2003 APPLICATION FOR BUILDING PERMIT Date oX , 2003 ` '' INSTRUCTIONS a. This application MUST be completely filled in by,typewriter or in ink and submitted to the Building Inspector with 3 sets of plans, accurate plot plan to scale.Fee according to schedule.. b.Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways.. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a•permit_:_._ shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 13 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to,the Building Department for the issuance of a Building Permit pursuant to the Building Zone.Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code, sing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. ('$igture of applicant or name,if a corporation) (Mailing address o applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises d5Eep.ew (As on the tA roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: ,200 PRAI77V LA"15 CcaIZ314fa6Y House Number Street, Hamlet County Tax Map No. 1000 Section_ k,(p Block Lot ' Z Subdivision Filed Map No. (Name) __._. 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction.-., a. Existing use and occupancy 5i ,-�6 1�g PA M i Ll eeS i r-d /C C b. Intended use and occupancy 3. Nature of work(check which applicable): New Building Addition t/ Alteration Repair Removal Demolition Other Work (Description)`'' C,& 4. Estimated Cost v2J, 01Y) — Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars A14 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. Al A 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories- Dimensions of same structure with alterations or additions: Front `Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front /2 4 r Rear Depth old s' 10. Date of Purchase Za-6 Name of Former Owner NhF M.05 �17,5clA A)i 11. Zone or use district in which premises are situated -16 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO '✓ 13. Will lot be re-graded? YES NO /Will excess fill be removed from premises? YES NO 14. Names of Owner of premises jA1AAjXZ L Address42CO PAl 7/1 &/✓&_ Phone No. 4 -134-q1 Name of Architect AlAky SS(j,�VATfvS Address0014e! MIA /,,/t Phone No 631 Sfax Qa. e of Contractor Address Phone No.his property within 100'feet of a tidal wetland or a freshwater wetland? *YES NOS, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? .* YES NO 4/ * IF YES, D.E.C.-PERMITS MAY BE REQUIRED. 16. Provide survey, to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OFv FCQ� being duly sworn, deposes ane says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the "" Q (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Swom to before e this �. da of 20 7-b� Notary Public Signature of Applicant ROBERT 1.SC JR. Notary Publie;Sta of., York Qualified in olk unty No.01 47250 Term Expires Nlay.31., . 01 Town Ha Annex l�f J�( Telephone(631)76�4802 54375 Main Road s(831)765-g50 P.O.Box 1179 , � roger.flchert(t�liown.southat�.ny.us Southold,NY 1197I-W59 BUILDING DEPARTMEW TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY` �A � f��1Vi56-Z, Date:. Company Name: Name: License No.: Address: ( OD Y1juI / ,bivlC>��-LLB G1C9' Phone No.: _ 7 JOBSITE INFORMATION: (Indicates required information) *Name: *Address: cZ06 l ' Gy lL *Cross Street: `Phone No.: V/0 �C_ Permit No.: -3 -7 7 5 3 Tax-Map District: 1000 Section:iT Block:� Lot: ' *BRIEF DESCRIPTION OF WORK(Please Print Clearly) (Please Circle All That Apply) Is job ready for inspection: YES/ NO. Rough In Final *Do•you need a Temp Certificate: YES I NO Temp Information(if needed) ' *Service Size: 1 Phase 313hase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82=Request for inspection Form 1 TOWN; OF SOUTHOLD PROPERTY RECORD CARD OWNER STREET VILLAGE DIST. SUB. LOT Gl►l lCe, u� � � 1 C' r:. a FORMER OWNER N E ACR. cthL , Van C.ct2Seele— 4'. S W TYPE OF BUILDING RES. 9 SEAS. VL. FARM COMM. CB. MILS. Mkt. Value. 22-9� LAND IMP. TOTAL DATE REMARKS 176 l 2 Q d 2 2, 0,Z. 2IJt 0d o/ ,A, -;�r76 Z, y r A7 o oo � z ��/ P V9' 9d g 03Cp q i e-AA Alp vree !'70 o cg 6 00 d 5 o oZ 3 143 i9�L,1 11 SS D ��03 G1.4/1�G� 4 u� --� 1-- ac az_i a - ?� C� a l - SGi a ril` "� l;y a�►�C( - c l�o, - 37�1 z4all CD Tillable FRONTAGE ON WATER �l �.� Woodland FRONTAGE ON ROAD Meadowl,and DEPTH House Plot BULKHEAD Total ■■■■■■■■■■■■■■■■■■ LONE■■e■■■ ■■■■■■■■■■■■■■OMEN I■■■1 ■■ONE ■■ IEEE■■■■■■■■■■■■■E$!■■el ■■mom ■■ ■■■ ■■■■■■ ■■■■■l=■■■e■I�i■■■©a■�I■e■1 No ON { , La n ■■■■®IN■■n■■■■■■MERM ■■■■■ s .- ME IEEEfir[■■■■■I!NE■■■■■■■om ENO ONE !■NIM■I■U■■■:-■ ■■■■■■ee■■■ ■■■ ■■� ■■� ■■■■■■■e■■e■■Nee■■ IEEE NEIMMMI■■■■■■■■■■■■■■■■■■■ ■■■■■■■�J■■■■■■■■■■■■■■■■■■■■■ ■eeeee■eeo■■■■■■■■■■■■ MEN Extension `■....■.....■■■■■■■eeee■■■■■e■e Porch 'Basement Porch Ext. V Interior Finish Breezeway Fire Place Garage •• • y ' �IIh®L�Recreation -• • ••• 'Rooms 2nd Floor IDormer MWA • • / • - BUILDING PERMIT EXAMINER CHECK LIST DATE REVIEWED: 5 /99/03 APPLICANT: , r� c� �o LQA 'DATE SUBMITTED: /,�/03 SCTM# DISTRICT: 1,000, SECTION: log , BLOCK: Fj LOT: aQG SUBDIVISION:7� ADDRESS: OCO?i L CL. CITY: 1 _ZONING DISTRIC'I` , iFORMING? BUILDING PERMITS OPEN/EXPIRED: BP 15:769 -Z/C/O Z- 4g6LI , INFO Q(t, /BP �,9 -Z/C/O Z-a- O4q , INFO BPCp30D-4-Z/ C/0 Z,&46aq, INFO )&p /BP -Z/C/0 Z- , INFO PRE CO: Y OR N BP -Z/ C/0 Z- , SINGLE & SEPARATE CERTIFICATION-REQUIRED ►gip NOTES: LOTS 40,000SF-100-24.Lot recognition.(CREATED before June 30, 1983),UNDERSIZED.,,QIS.FtROW,,J,kN-:199�"MO'25.Merger.(A nonconfonning at any time after 7/1/; REQ. LOT SIZE:,�-10, pc> ACT. LOT SIZE: REQ. LOT COV. ab ACT. LOT COV. t/ REQ. FRONT 5-C-) PROP. FRONT�_REQ SIDE ACT. SIDE ✓ REQ. REARS 'D_PROP. REAR 450 REQ. HEIGHT PROP. HEIGHT PROJECT DESCRIPTION: 4pmcl'5' ESTIMATED PROJECT COST4- QnL 4�T/ENGINEER:^ FAST TRACK FAO WATER FRONT? NO DESCRIPTION: PANEL #: 1 FLOOD ZONE: K COMPLIANCE: ✓ APPROVALS REQUIRED SUFFOLK COUNTY HEALTH D PT: YES og�, (BED #): DTE: / / PERMIT#: TOWN SEPTIC RECEIPT: Y or NEW YORK STATE DEC: PRE-DEC 9/1/75 YES of N SOUTHOLD TOWN TRUSTEES: YES oF TOWN ZONING BOARD APPROVAL: YES oTOWN PLAN. BOARD APPROVAL: YES or TOWN HISTORICAL PRE (SPLIA): YES or NEW YORK STATE CODE COMPLIANCE (SEE PAGE 2): ES or NO oh NOTES: FEE STRUCTURE: FOUNDATION: SF FIRST FLOOR: , SF SECOND FLOOR: SF OTHER: SF INIT OTHER TOTAL TOTAL: SF FEE FEE FEE 1. ( -SF)- ( SF)= SF X $ =$ +$ +$ = $ 2. ( SF)- ( SF)= SF X $ _$ +$ +$ _ $ 3. ( SF)- ( SF)= SF X FINAL TOTAL: $ NEW YORK STATE CODE COMPLIANCE CHECKLIST USE/OCCUPANCY CLASSIFICATION: HEIGHT/FIRE AREA: i -TYPE OF CONSTRUCTION: DESIGN CRITERIA: ENGINEERE SCRIP E W- kA FULL FRAMING DESIGN ELEMENTS: HEADERS WALL STUDS:OWN GIRDERS: (UN CEILING JOISTS: VN FLOOR JOISTS: Z/N ROOF RAFTERS:&N LUMBER SPECIES AND GRADEO)N DESIGN LOAD CALCULATIONS: N f SHOULD INCLUDE LIVE,DEAD,SNOW,SEISMIC AND WIND(INCLUDING UPLIFT AND EXPOSURE) WINDOW AND DOOR SCHEDULE: / MISSLE TEST REQUIREMENTS:&IN EGRESS, LIGHT,, VENT: Y/N LOAD PATHS: Y/N ✓ ROOF TO FOUNDATION NAILING/CONSTRUCTION SCHEDULOMN MEANS OF EGRESS: Y/N PLUMBING RISER DIAGRAM1 LOCATION OF FIRE PROTECTION EQUIPMENT: Y/N TRUSS DESIGN: Y/N CERTIFICATION: Y/N ENERGY CALCS:O/N TOTAL COMPL CE Y (RETURN TO PAGE ONE) pF SO!/Tyol t o Town Hall,53095 Main Road Fax(631)765-9502 P.O.Box 1179 G Telephone(631)765-1802 Southold,New York 11971-0959 �Q 'rou�m,��' BUILDING DEPARTMENT TOWN OF SOUTHOLD May 30th, 2006 Edward E. Wankel P.O. Box 1275 Cutchogue, N.Y. 11935 RE: 1200 Praity Lane SCTM# 109 0005 026 Dear Mr. Wankel, Please be advised that your Building Permit#29435 issued May 28th, 2003 has expired. According to the Code of the Town of Southold, a Certificate of Occupancy must be issued prior to use of the structure. To renew your Building Permit,please submit a fee of$150.00 at that time we can schedule an inspection by one of our Building Inspector's. If you have any questions,please call us at 631-765-1802. Respectfully, SOUTHOLD TOWN BUILDING DEPT. • O��pF 50!/ryol � o Town Hall,53095 Main Road Fax(631)765-9502 P.O.Box 1179 G • Q Telephone(631)765-1802 Southold,New York 11971-09 BUIL ING DEPARTMENT \. TO OF SOUTHOLD j March 20th, 2007 Edward E. Wankel P.O. Box 1275 Cutchogue,N.Y. 11935 2ND NOTICE RE: 1200 Praity La. (alteration/addition) SCTM: 109 5 26 Dear Mr. Wankel, Please be advised that your Building Permit#29435 issued May 28th, 2003 has expired. According to the Code of the Town of Southold, a Certificate of Occupancy must be issued prior to use of the structure. To renew your Building Permit, please submit a fee of$150.00; at that time we can schedule an inspection by one of our Building Inspector's. If you have any questions,please call us at 631-765-1802. Respectfully, SOUTHOLD TOWN BUILDING DEPT. • pF SOUryolo Y ' Town Hall,53095 Main Road Fax(631)765-9502 P.O.Box 1179 G • Q Telephone(631)765-1802 Southold,New York 11971-0959 olyIrou BUILDING DEPARTMENT TOWN OF SOUTHOLD February 21". 2008 FINAL NOTICE EdwardE. Wankel' k- ll P.O. Box 1275 Cutchogue, N.Y. 11935 RE: 1200 Praity Lane. (AlteratioWAddition) SCTM.- 109.-5-26 Dear Mr. Wankel, Please be advised that your Building Permit#29435 issued May 28`h, 2003 has expired. According to the Code of the Town of Southold, a Certificate of Occupancy must be issued prior to use of the structure. To renew your Building Permit,please submit a fee of$150.00; at that time we can schedule an inspection by one of our Building Inspector's. If you have any questions,please call us at 631-765-1802. Respectfully, SOUTHOLD TOWN BUILDING DEPT. pF SOUryolo Town Hall Annex Telephone(631)765-1802 54375 Main Road N Fax(63 I)765-9502 P.O.Box 1179 G • OQ Southold,New York 11971-0959 �� a �y�DUNT`1,0c� BUILDING DEPARTMENT TOWN OF SOUTHOLD January 21st, 2009 Edward Wankel Judith Gordon P.O. Box 1275 Cutchogue, N.Y. 11935 Re: 1200 Praity Lane / Violation SCTM# 1000-109. -5-26 To Whom This May Concern: Your BUILDING PERMIT # 29435 for construction of an ALTERATION/ADDITION has been referred to me because you have not responded to requests to obtain your Certificate of Occupancy as required by Southold Town code. Pursuant to 144-15A, of the Southold Town Code, "No building hereafter erected shall be used or occupied in whole or in part until a certificate of occupancy shall have been issued by the Building Inspector." Therefore, you have ten days from the receipt of this letter to submit a check made out to the Town of Southold in the amount of $150.00: to renew the building permit, or legal action will be taken against you. Should you have any questions, call the building department between the hours of 8:00 a.m. and 4:00 p.m. Respectfully Yours, Damon Rallis, Zoning Inspector Southold Building Department ' 0 p0❑� 5p$3 3?54 18 70p8 3 Southold Town Building Department �o�OS' �F 'ta P.O.Box 1179 Permit#: 35362 54375 Main Road o _ Southold,New York 11971 Permit Date: 3/1/2010 �l �a (631) 765-1802 Expiration Date: 9/1/2011 at Parcel ID: 109.-5-26 BUILDING PERMIT RENEWAL LETTER Dated: 5/30/2012 Applicant: EDWARD WANKEL& JUDITH GORDON Location: 1200 PRAITY LANE CUTCHOGUE Work Description: ADDITION/ALTERATION ADDITIONS &ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR.REPLACES EXPIRED BP#29435 A FEE OF $75.00 IS REQUIRED TO RENEW THIS BUILDING PERMIT. Owner: EDWARD WANKEL&JUDITH GORDON Address: P.O. BOX 1275 CUTCHOGUE,NY 11935 The permit listed above has expired. Please contact our office as soon as possible to begin the renewal process. All work on the project must stop on the expiration date. No work is permitted or authorized beyond the expiration date. THANK YOU, SOUTHOLD TOWN BUILDING DEPT. ,:��� Southold Town Building Department 000tir,r P:O.Box 1179 ° Permit#: 35362 54375 Main Road 0 coX. Southold,New York 11971 Permit Date: 3/1/2010 (631)765-1802 Parcel ID: 109.-5-26 Expiration Date: 9/1/2011 BUILDING PERMIT RENEWAL LETTER FINAL NOTICE Dated: 11/16/2012 Applicant: EDWARD WANKEL & JUDITH GORDON Location: 1200 PRAITY LANE CUTCHOGUE Work Description: ADDITION/ALTERATION ADDITIONS & ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR.REPLACES EXPIRED BP # 29435 A FEE OF $125.00 IS REQUIRED TO RENEW THIS BUILDING PERMIT. Owner: EDWARD WANKEL & JUDITH GORDON Address: P.O. BOX 1275 CUTCHOGUE, NY 11935 The permit listed above has expired. Please contact our office as soon as possible to begin the renewal process. All work on the project must stop on the expiration date. THANK YOU, SOUTHOLD TOWN BUILDING DEPT. Permit Number REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheck$oftware Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\WANKEL.rck TITLE:WANKEL I GORDON RESIDENCE ADDITION COUNTY: Suffolk STATE:New York HDD: 5750 CONSTRUCTION TYPE:Detached 1 or 2 Family HEATING TYPE:Non-Electric DATE:05/13/03 DATE OF PLANS:4-29-03 COMPANY INFORMATION: WARD ASSOCIATES,P.C. COMPLIANCE:Passes Maximum UA=46 Your Home UA=44 4.3%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Cathedral Ceiling(no attic) 128 30.0 0.0 4 Skylight 1:Wood Frame:Double Pane with Low-E 6 0.240 1. Wall 1:Wood Frame, 16"o.c. 288 19.0 0.0 14 Window 1:Wood Frame:Double Pane with Low-E 20 0.340 7 Window 2:Other 32 0.440 14 Floor 1 All-Wood Joist/Truss:Over Unconditioned Space 128 30.0 0.0 4 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York"State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment, such plans or specifications are in mpliance with this ode. Builder/Design er Date G\S��`R�� AR�tij ����G� M• FFF��`TFp� . s s� 15589 + OF N VN ' L r REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheck Software Version 3.5 Release lb DATE: 05/13/03 TITLE: WANKEL I GORDON RESIDENCE ADDITION Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Cathedral Ceiling(no attic),R-30.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Windows: [ ] 1. Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 2. Window 2:Other,U-factor:0.440 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: Skylights: [ ] 1. Skylight 1:Wood Frame:Double Pane with Low-E,U-factor:0.240 For skylights without labeled U factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: Floors: [ ] 1. Floor 1: All-Wood Joist/Truss:Over Unconditioned Space,R 30.0 cavity insulation Comments: Air Leakage: [ ] Joints,penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] ( Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: ` [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [ ] Materials:and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-8. [ ] Return ducts in unconditioned attics or outside the building must be insulated to RA [ ] Supply ducts in unconditioned spaces must be insulated to R-8. [ ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2. J Insulation is not required on return ducts in basements. Duct Construction: [ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State ,the Residential Code of New York State or the New York City Building Code ,as applicable. Service Water Heating: [ ] J Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2. a " Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1„ Up to 1.25" 1,5"to 2.0" Over 2" 170-190 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for ITVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 L5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) D o d o � a o GENERAL CONSTRUCTION PLUMBING ELECTRICAL 1. GENERAL 1. GENERAL - FURNISH ALL LABOR, MATERIALS, EQUIPMENT, PLANS, TOOLS, AND SERVICES NECESSARY AND REQUIRED 1 . GENERAL - FURNISH ALL LABOR, MATERIALS, EQUIPMENT, PLANS, TOOLS, AND SERVICES NECESSARY AND REQUIRED PROJECT INCLUDES THE CONSTRUCTION OF A NEW RESIDENCE INCLUDING BUT NOT LIMITED TO EXCAVATION, FOR PROPER AND COMPLETE INSTALLATION OF ALL PLUMBING SYSTEMS AND RELATED WORK TO INCLUDE BUT NOT FOR PROPER ,AND COMPLETE INSTALLATION OF ALL ELECTRICAL SYSTEMS AND RELATED WORK TO INCLUDE BUT NOT FOUNDATIONS, (UTILITIES, FRAMING, INSULATION, WINDOWS AND DOORS, FINISHES, SIDING, ROOFING, PLUMBING, HVAC BE LIMITED TO, WATER SUPPLY AND DISTRIBUTION PIPING, DRAINAGE PIPING, PLUMBING FIXTURES, VALVES, TRAPS, BE LIMITED TO: INSTALLATIONS OF NEW WIRING, CIRCUITS, LIGHTING EQUIPMENT Q CONNECTIONS, DISTRIBUTION AND AND ELECTRICAL SYSTEMS, LANDSCAPING AND PAVEMENTS. CONTRACTOR SHALL OBTAIN ALL PERMITS, UL CERTIFICATES WASTE AND VENT PIPING, INCLUDING ALL THEIR RESPECTIVE CONNECTIONS, DEVICES, APPURTENANCES WITHIN THE PROTECTION EQUIPMENT, APPLIANCE CONNECTIONS, AND CONNECTION OF ALL DEVICESSWITHINHINTHE SCOPE OF WORK AS AND FINAL C.O.. ADDITION AREA. PLUMBING FIXTURES TO INCLUDE, BUT NOT BE LIMITED TO: LAVATORIES, JACUZZI TUB, SHOWER, SHOWN ON THE APPLICABLE DRAWINGS AND AS NORMALLY SPECIFIED IN THIS 2, CONCRETE - 3'i500 PSI AT 28 DAYS ASTM 94 READY-MIXED CONCRETE. BIDET AND WATER CLOSET. RELOCATE EXTERIOR HOSE BIB AND IRRIGATION SYSTEM PIPING. TYPE OF PROJECT. 2. CODES: ALL WORK SHALL CONFORM TO THE 3. STEEL BAR REINFORCING - ASTM 615 WELDED WIRE FABRIC - ASTM A-i'35' REQUIREMENTS OF THE LOCAL BUILDING CODE AND THE NATIONAL 4. STRUCTURAL STfEEL 2. CODES - ALL WORK SHALL CONFORM TO THE REQ0REMENTS OF THE CODE(S) HAVING JURISDICTION ELECTRIC CODE (NEC), LATEST EDITION. EEL - (LINTELS, PLATE, GIRDERS, ETC.) TO BE ASTM A-572 GRADE PRIME PAINTED. 3. PIPING - COLD HOT WATER AND PIPING - TYPE l._ COPPER TUBING E „5. VAPOR BARRIER - ASTM E-96 POLYETHYLENE FILM 6 MIL THICK WITH TAPED SEAMS. / (ANSI H231) WITH SOLDER TYPE FITTINGS AND 3• CIRCUIT BREAKERS - SINGLE POLE 15 AND 20 AMPERE CIRCUIT BREAKERS SHALL BE UL LISTED, AS SWITCHING 6. LUMBER JOINTS MADE WITH 95/5 SOFT METAL SOLDER. BELOW GROUND PIPING TO BE TYPE K COPPER TUBING. RISERS AND BREAKERS" AT 120 V A.C. AND CARRY THE SWD MARKINGS. CIRCUIT BREAKERS SHALL BE UL LISTED. SINGLE POLE A. DOUGLAS FIR NO. 1 GRADE WITH BASE Fb = 1000 PSI AND E = 1;700,000, 19% M.C. max, MAINS TO BE 3/4 INCH, ALL BRANCH LINES TO FIXTURES TO BE 1/2 INCH. PROVIDE SHUTOFF AND DRAIN VALVE IN BREAKERS WITH HANDLE TIES- NOT ACCEPTABLE. B. PLYWOOD CRAWL SPACE FOR EACH RISER AND PROVIDE VALVIE TAG IDENTIFICATION. 4. CABLE & WIRING 1 SUBFLOOR - 3/4" TH., C-D INTERIOR APA WITH EXTERIOR GLUE.. (PL-PREMIUM GLUE DOWN WITH NAILING) 4, DRAINAGE PIPING - SANITARY PIPING SHALL BE .COIPPER OR PVC. PROVIDE CONNECTION TO EXISTING RESIDENCE A. BRANCH CIRCUITS (INTERIOR) - TYPE NM OR NMC 2 WALL SHEATHING - 5/8" EXTERIOR GRADE APA, FIR PLYWOOD SANITARY DRAIN SYSTEM. B. SERVICE ENTRANCE (DIRECT BURIAL) - TYPE USE 3 ROOF SHEATHING - 24/0, 3/4" TH., C-D EXTERIOR APA, FIR PLYWOOD. C. FEEDERS - TYPE NNM, NMC, OR SEC I 5. SANITARY VENT PIPING - PVC PIPE AND FITTINGS OR AS REQUIRED BY LOCAL CODE. ( ) - TYPE OF - (NIC) 4 MARBLE & TILE SUBFLOORS - 3/4" TH. C-D EXTERIOR APA. (PL-PREMIUM GLUE DOWN WITH NAILING) WITH 6. FLASHING - FLASHING MATERIALS TO BE 16 OZ. COPPER MIN. D. UNDERGROUND DISTRIBUTION DIRECT BURIAL UNDERLAYMENT - 1/4" AC PLYWOOD (FIR). 7. HOSE BIB - HOSE BIBS TO BE NON-FREEZE TYPE' WITH INTERIOR SHUTOFF VALVE. E. CONDUCTORS TO BE COPPER C. CONNECTORS - SIMPSON STRONG-TIE OR EQUAL, ALL TO BE GALVANIZED. 8. PLUMBING FIXTURES - CONTRACTOR TO PROVIDE AILL ROUGHING, VALVES, FITTINGS, ETC. FOR COMPLETE JOB. (THE F. INSULATION (600 VOLT) �,`10 AWG AND SMALLER - THWN/THHN, #8 AWG AND LARGER - THN, THWN, D. SILLS - SOUTHERN YELLOW PINE #2 OR BETTER, CCA TREATED (.40 PCF) OWNER WILL SELECT FIXTURES AND FITTINGS. ALL FIXTURES SHALL BE KOHLER IN COLOR AS SELECTED BY THE XHHW (PVC FOR NM OR OF CABLES). KDAT. OWNER. ALL FITTINGS SHALL BE IN FINISH SELECTED BY OWNER. G. NEUTRAL WIRE SHALL HAVE A WHITE OUTER COVERING THROUGHOUT SYSTEM. EQUIPMENT GROUND WIRE SHALL E. SOFFITS: 3/8" EXT. GRADE A-C PLYWOOD APA. PRE-STAIN ALL SURFACES WITH SOLID STAIN TO MATCH SIDING. - WATER CLOSET SHALL BE KOHLER AS SELECTED. HAVE A GREEN OUTER COVERING THROUGHOUT SYSTEM, MARK CABLES OR WIRE WITHOUT COLOR CODED JACKETS 7. ROOFING - GAIF TIMBERLINE ULTRA WITH TIMBERTEX RIDGE MATERIAL, ICE 'AND WATER-SHIELD AT VALLEYS/EAVES. - LAVATORIES SHALL BE CAXTON WITH GROHE CLASSIC WITH FINISH FITTINGS AS SELECTED. WITH NON-FADING COLOR CODED TAPE AT TERMINATIONS AND OTHER ACCESSIBLE LOCATIONS. 8• LEADERS & GUTTERS - 6" COMMERCIAL ALUMINUM GUTTERS AND LEADERS, COLOR SHALL BE AS SELECTED. PROVIDE 5. , - WHIRLPOOL BATH SHALL BE KOHLER AS SELECTED. GROHE CLASSIC FITTINGS AS SELECTED. RACEWAY - RACEWAY TO BE RIGID METAL CONDUIT OR SCHEDULE 40 PVC (WHERE PERMITTED BY CODE). CONTINUOUS LEAF GUARDS AND ROOF HANGERS AT 30" MAXIMUM. - BIDET' SHALL BE KOHLER AS SELECTED WITH IGROHE CLASSIC BRASS FITTINGS. 6. OUTLET BOXES - OUTLET BOXES IN DRY CONCEALED LOCATIONS FOR WOOD FRAME CONSTRUCTION TO BE PVC WALL 9• SHEET METAL FLASHINGS & ROOFING - SHALL BE 16 OUNCE COPPER AT`ALL ROOF PENETRATIONS AND WALL/ROOF - SHOWER FITTINGS SHALL BE GROHE TWO WALL CUSTOM SHOWER SYSTEM. BOXES AND NORYL CEILING BOXES. IN EXPOSED LOCATIONS USE 4" SQUARE CAST ALUMINUM BOXES AND FINISHED INTERSECTIONS, AND ROOFING. 9• VALVES -. VALVES TO BE BRASS/BRONZE BODY - 125 PSIG. ALL VERTICAL SUPPLY RISERS AND BRANCH LINES WEATHERPROOF COVERS. 10, TERMITE SHIELDS - SHALL BE .019" ALUM. WITH SEALANT JOINTS AT LAPS AND BOLT PENETRATIONS. SHALL BE PROVIDED WITH DRAIN TEES AND SHUTOFF VALVES IN THE CRAWL SPACE. 7• SWITCHES - SWITCHES, PRESSURE-SENSITIVE TYPE, 15 AMP, 120/277 VOLT, BACK AND SIDE WIRED SINGLE POLE, 11. PROVIDE SILL SEALER (POLYETHYLENE) UNDER CCA STILL PLATES. { 10. CLEANOUTS - CLEANOUTS TO BE FULL SIZE OF PIPE WITH THREADED BRASS SCREW PLUGS. DOUBLE POLE, THREE-WAY AND DIMMER TYPE AS REQUIRED. DECORA TYPE, 12. FASCIA & WOOD TRIM - CLEAR CEDAR, 5/4 x 6 FASCIAS, 1 x 3 TRIM, 5/4 x 4 CASING AND OTHER TRIM AS SHOWN. 11. PLATES - PLATES FOR FINISHED SPACES TO BE CHROME PLATED SPLIT BRASS, 8. EQUIPMENT WIRING - PROVIDE AND INSTALL ALL LINE VOLTAGE WIRING FOR EQUIPMENT BY OTHER TRADES, ON THE ELEVATIONS. BACKPRIME AND PRE-STAIN ALL EXTERIOR WOOD. 12. PIPE INSULATION - PIPE INSULATION TO BE CELLULAR FOAM OF THICKNESS REQUIRED BY THE ENERGY CONSERVATION 9. DUPLEX RECEPTACLES - PROVIDE 15 AMP 125 VOLT BACK AND SIDE WIRED DUPLEX RECEPTACLES ON ALL 13. SIDING - CLEAR BEVEL CEDAR SIDING - PERFECTIONS. PRE-STAIN WITH ` OLID STAIN.(CABOT'S, BENJAMIN MOORE, / CONSTRUCTION CODE; PR 1.EL TANK WITH 2 FOAM INSULATION. CUPRONICKEL HEAT EXCHANGER, ON ALL INTERIOR COLD AND HOT WATER AND AIR HANDLER PIPING. MULTI-RECEPTACLE 15 AND 20 AMPERE CIRCUITS, PROVIDE 200 AMP 125 VOLT BACK AND SIDE WIRED DUPLEX OLYMPIC) INSTALL OVER TYVEK HOUSEWRAP WITH TAPED SEAMS. J 13. HOT WATER STORAGE - 40 GALLON STAINLESS STE RECEPTACLE ON ALL SING , LE RECEPTACLE 20 AMPERE CIRCUITS. GROUND FAULT CIRCUIT INTERRUPTING - 20 AMP 125 14, WALL BASE - 1" x 6" HEIGHT CLEAR CHERRY WITH OGEE TOP EDGE. i THERMOSTATIC ALLY CONTROLLED. SUPER - STOR NODEL NO.SS-40 AS MANUFACTURED BY HYDRO-THERMAL SYSTEMS, VOLT WITH INDICATOR. REPLACE LL EXISTING OUTLETS AND PLATES. ALL DECORA TYPE. 15, INSULATION - (FIBERGLASS & RIGID INSULATION. BATTS WITH VAPOR BARRIER BY OWENS-CORNING. INC. OR APPROVED EQUAL. PROVIDE COMPLETE WITH TEMPERATURE GAUGE AND RELIEF VALVE. 10. PLATES - PROVIDE PLATES FGR ALL OUTLET BOXES (RECEPTACLES, SWITCH, TELEPHONE, BLANK OR COMBINATION). THICKNESS AS FOLLOWS: 14. CIRCULATORS - CIRCULATOR, ONE FOR THE HEATIIII(G ZONE, ONE FOR THE WATER HEATER, AND ONE FOR RADIANT SMOOTH PLASTIC UREA (WHITE COLOR) UNLESS INDICATED, OTHERWISE. MULTI-GANG SWITCHES, RECEPTACLES, ETC. A. R-30C - BETWEEN RAFTERS (VENT SPACE ABOVE) 12" ABOVE ATTIC, CEILING (FLAT AREAS) HEAT ZONE (IF USED) TO BE B & G, SERIES 10, SIZED FOR APPROPRIATE GPM WITH SETTLEABLE FLOW CHECK. SHALL BE IN A COMMON, ONE-PIECE PLATE. DECORA TYPE. B. R-30" - BETWEEN CRAWL SPACE AND FIRST FLOOR. PIPE SIZE 1 INCH, SEALS TO BE SUITABLE FOR (GLYCOL SOLUTION, CONNECT PIPING TO EXISTING HOT WATER 11. BATHROOM VENT UNIT - BROf,N SENSAIRE MODEL N0. MHS120L, 120 CFM, MOTION AND HUMIDITY SENSING UNIT. C. 2" - EXTRUDED POLYSTYRENE RIGID INSULATION, R-10 MIN. MASTIC', APPLICATION. HEATER AND BOLLER, PROVIDE COMPLETE WITH LIGHTING, BATTERIES, DUCT KITS AND SOFFIT/WALL VENTS. COLOR TO MATCH ROOFING. 16. DOORS AND WINDOWS 15. WATER SOFTENER - PROVIDE AND INSTALL MERMAID) ACID NEUTRALIZER, MODEL NO. AN-30RE AND MERMAID WATER A. INTERIOR DOORS, SOLID WOOD, 4 PANEL DOORS. STAIN/POLYURETHANrE, FINISH AS SELECTED. SOFTENER, MODEL NO. AST-30RE. PROVIDE TWO YEAR PARTS AND LABOR WARRANTY TO OWNER. 12• LIGHTING FIXTURES - LIGHTING FIXTURES TO BE .HALO (HIGH HATS) OTHER FIXTURES AS SELECTED BY OWNER. PROVIDE B. WINDOWS AIND GLASS DOORS - ANDERSEN CO., "STORMWATCH", PERMA-SHIELD HIGH PERFORMANCE, COLOR AS 16. STEAM SHOWER UNIT - MODEL NO SM-3PB AS MAINUFACTURED BY STEAMIST OR EQUAL. LOCATE REMOTE UNIT IN ' ALLOWANCE OF $1000 FOR LIGHTING FIXTURES. SELECTED. ALL WITH SCREENS TO MATCH. PROVIDE EXTENSION JAMBS. MARINE GRADE EGRESS HARDWARE- FINISH CRAWL SPACE. 13. SECURITY, CARBON MONOXIDE & FIRE PROTECTION SYSTEM. 17. MANUALS CONTRACTOR TO PROVIDE ALL PRODUCT LITERATURE, WARRANTIES, AND INSTRUCTION TO OWNER. / °� A. FIRE AND SMOKE DETECTORS SHALL BE PROVIDED IN EACH HABITABLE SPACE. AS SELECTED. ✓C. DOOR FRAMES - TO BE MADE UP FROM 5/4" CHERRY WITH INTEGRAL STOP AND DEVICES SHALL BE DIRECT CONNECT WITH LIGHTS AND BATTERY BACK-UP. BUILT- UP WOOD INTERIOR TRIM 18. CLEANUP - CONTRACTOR TO CLEAN UP AND DISPOSE OF DAILY, ALL HIS TRADE RELATED DEBRIS AND WASTE B. PROVIDE CARBON MONOXIDE( DETECTION/ALARM SYSTEM AS PART OF TOTAL SYSTEM. 5/4 x4 WITH PROFILED EDGE AS SELECTED. MITER ALL CUTS. � MATERIALS. 14. ELECTRICAL EQUIPMENT - ALL NECESSARY WIRING, SWITCHES; MOTORS, AND OTHER ELECTRICAL EQUIPMENT REQUIRED j 17. CAULKING - LEXCEL EXTERIOR; ACRYLIC LATEX INTERIOR. BY OTHER TRADES (WITH SPECIAL I EMPHASIS ON THE HEATING -AND A R. ...CONDITIONING SYSTEM) SHALL BE..PROVIDED AS 18. ADHESIVES - Pt PREMIUM AS MANUFACTURED BY CONTECH BRANDS (TO CBE USED IN ADHERING PLYWOOD SUBFLOOR NECESSARY FOR A COMPLETES'Of�ERATIONAL SYSTEM. TO FLOOR JOISIES). 15. CABLES - COORDINATE TELEPHONE AND CABLE TV JACKS, AND SECURITY CONNECTIONS AND BE SCHEDULED WITH THE 19. HARDWARE OWNER AND THE LOCAL UTILITY COMPANY. AS REQUISITE,'FOR FINAL ACCEPTANCE AND PAYMENT, DELIVER TO OWNER TWO A. LOCKSETS - BALDWIN 5440 LEVER TYPE OR AS SELECTED. FUNCTIONTO MATCH SPACE UTILIZATION. FINISH AS SELECTED. HVAC (2) COPIES OF A CERTIFICATE FROM UL AND LOCAL AUTHORITY, SHOWING ACCEPTABILITY OF WORK DONE UNDER THIS B. HINGES - HAGER, STANLEY OR EQUAL - BALL TYPE FINIALS, REMI,)VABLE PINS. / CONTRACT, C. MISCELLANEOUS - STANLEY (CAB. PULLS, ETC.). 1: GENERAL - FURNISH ALL LABOR, MATERIALS, EQUIPMENT, PLANS, TOOLS AND SERVICES NECESSARY AND REQUIRED 16. POWER INTERRUPTIONS - ALL REQUIRED POWER, TELEPHONE, AND CABLE TV INTERRUPTIONS SHALL OPERATIONAL CHECKS D. STOPS - FLUSH BOLTS, PULLS, BUMPERS - IVES. f`' ,, ,., FOR PROPER AND COMPLETE INSTALLATION OF ALL IHEATING, VENTILATING, AND AIR CONDITIONING SYSTEM AND WITH THE RESPECTIVE COMPANES. , 20. GYPSUM BOARD 17. MANUALS - CONTRACTOR TO �F;OVIDE ALL PRODUCT RELATED `WORK. HVAC SYSTEMS WILL,INCLUDE, BUTI NOT BE LIMITED TO, AIR HANDLING, VENTING, DUCTWORK AND CT LITERATURE, WARRANTIES, AND INSTRUCTION TO OWNER. A. INTERIOR WAALLS AND CEILINGS, 5/8" THICK, TAPE AND SPACKLE ALL! JOINTS. ALL SYSTEM RELATED PIPING,' VALVING CONTROLS AND WIRING � CLEANUP - '� ' 'ELECTRICAL COORDINATION WITH ELECTRICAL 18. CONTRACTOR TO LEAN UP AND DISPOSE OF DAILY ALL HIS TRADE RELATED DEBRIS B. BATHROOM WALLS AND CEILINGS, 5 8" THICK WR, TAPE AND SPACK� 'SYSTEM, AND WASTE MATERIALS. / � ' CONTRACTOR FOR LINE VOLTAGE WIRING, AND ALL hJ'IECESSARY DEVICES FOR COMPLETE FULLY OPERATING 2 CODES - ALL WORK SHALL CONFORM TO T ` . C. WONDERBO�ARD FOR TUB SURROUNDS AND TILE SHOWERS. . HE REQUIREMENTS ,OF THE LOCAL BUILDING CODE(S) 21: MARBLE AND CERAMIC TILE & WALLBASE - AS ,SELECTED BY -OWNER. PROVIDE $4,000 LABOR AND MATERIAL ALLOWANCE. _ 3. HEATING & COOLING SYSTEM . EXTEND EXISTING HVVAC .ZONE TO NEW ADDITION. WORK SHALL BE COMPLETE WITH 22, CABINETS & BATHROOM VANITIES ''-°AWI CUSTOM QUALITY WITH MARBLE COUNTER TOPS, UNITS SHALL INCLUDE BATH 1 VANITIES AND BASE CABINETS, JACUZZI TUB SURROUND AND LINEN STORI,GE SHELVES. PROVIDE ALLOWANCE AMOUNT OF DUCTWORK, HEAT EXCHANGER, REGISTERS, GRILLES; CONTROLS AND RELATED ACCESSORIES. $2500 FOR MATERIALS, FABRICATION AND INSTALLATION. 4• THERMOSTAT - THERMOSTAT TO BE HEATING/COOLING, DAY/NIGHT SET BACK, DIGITAL, ELECTRONIC 24, PAINTING TYPE WITH CLOCK. CONTROL WIRING BY, HVAC CONTRACTOR. A. EXTERIOR WALLS - WOOD SIDING, SOFFITS, FASCIA AND TRIM - SOLID STAIN, TWO (2) COATS. COLOR AS SELECTED. 5. DUCT WORK - DUCT WORK TO BE FABRICATED IN I ACCORDANCE WITH SMACNA STANDARDS INCLUDING TRANSITIONS, i � N 7�'16,5o"lU MATCH EXISTING. BENDS, TAKE-OFFS, ETC., DESIGNED FOR MINIMUM 13 STATIC LOSSES, DUCT MATERIAL TO BE GALVANIZED SHEET METAL OF 26 GAUGE UP TO 24 INCHES WIDE AND 24 .GAUIGE ABOVE 24 INCHES WIDE. SEAMS AND JOINTS SHALL BE SUCH N COMPLY WITH ALL CODES OF B. INTERIOR WALLS - ONE (1) COAT SEALER, TWO (2) COATS FLAT - COLOR AS SELECTED. BATHROOM - SATIN FINISH. THAT LEAKAGE IS NOT MORE THAN .3%. DUCTS SHALL HAVE RIGID FIBERGLASS ACOUSTICAL AND THERMAL LINERS, 2 "°�v RIC STATE & TOWN CODES BENJAMIN MAOORE. INCH THICK FOR SUPPLY AND 1/2 INCH FOR RETURN. APPROVED A TED O S C. ALL INTERIOR WOODWORK - ONE (1) COAT SEALER, TWO (2) COATS SATIN FINISH, POLY OR COLOR AS SELECTED. � IGHT OF WAY AS �EQ I �rzr�, � ,CONDITIONS ®F �. 6. FILTERS - FILTERS SHALL BE SPACE GARD, MODEI,, 12200, HIGH EFFICIENCY UNITS. EIGHT INCH DEEP PLEATED 77)T7 t �� �,...BENJAMIN Iw100RE. DATE: 8.P•#t � UNIT, RATED AT 99% EFFICIENT WITH 6 MICRON SIZE PARTICLES. SOtlf}Ia�,9WNZ8A 25. BATHROOM ACCESSORIES (SUPPLIED BY OWNER, INSTALLED BY CONTRACTOR). FEE:< � BY: ,..�,.. r A. TWO (2) TOWEL BARS 7. DIFFUSERS - SUPPLY DIFFUSERS TO BE CARNES OIR EQUAL. ADJUSTABLE OPPOSED BLADE DAMPERS. WHITE. NOTIFY BUILDING DE�ARTMF.J t. AT '� SOUiH�INrOW�1PlANNING�QARD B. TOILET PAPER DISPENSER 8. RETURN GRILLS - HART & COOLEY OR APPROVED ',EQUAL. WHITE. SOUM OjO TOWNPLANNING 765-1802 8 AM TO A M C. ROBE HOOKS - TWO 9. DUCT WORK - DUCT WORK TO BE INSTALLED TO BE FREE FROM VIBRATION, AND SUPPORTED AT 4 FT. ON CENTER FOLLOWING INSPECT ;"D. SHOWER ENCLOSURE - LUXUS SERIES 30, NEO ANGLE FRAMELESS; TEMPERED GLASS TRUSTEES MAX.. DUCT JOINTS SHALL BE PROPERLY SEALED iT INCH ON EACH SIDE OF JOINT.. PROVIDE ISOLATION PADS AND DRIP .�' ' 26. CLEANUP - PROVIDE GENERAL CLEANUP OF PROJECT SITE DURING CONSTRUCTION, AND AT COMPLETION OF PROJECT PANS WITH CONDENSATE PIPING TO EXTERIOR FOR!ALL AIR HANDLER UNITS. 1. FOUNDATION TY 0 N.Y.J.DEC PROVIDE FINAL "'MOVE IN" CLEANING OF WINDOWS, DOORS, FLOORS AND WOODWORK INCLUDING ANY NECESSARY PAINT 10. VOLUME DAMPER - PROVIDE VOLUME DAMPER, O (OTHER APPROVED AIR BALANCING DEVICE, FOR POURED TOUCHUP. WITH INDICATING AND 2, ROUGH - Ft A LOCKING QUADRANT, PROVIDE AT EACH MAIN .DUCT ,AT EACH DUCT TAKE-OFF AND AT EACH NECK TO INDIVIDUAL 3 INSULATION, C�C'R1Ir ICATION O11 31. GENERAL NOTES DIFFUSER OR REGISTER IN SUPPLY, RETURN OR EXHAUST DUCT. EX 1 STY CONNFC-(IONS DWG. AND OTHER EQUIPMENT THAT 4. FINAL • CO1VS ,,L NAI NG A. ALL WORK 'TO BE DONE IN ACCORDANCE WITH THE LOCAL BUILDING AND NEW YORK STATE ENERGY CONSERVATION 11. ACCESS DOORS - PROVIDE ACCESS DOORS AS REQ;'JIRED FOR COILS, FILTERS, DAMPERS, BE COMPLt EpUIVIED• CONSTRUCTIION CODE, NEW YORK STATE RESIDENTIAL CODE AND THOSE OF THE LOCAL GOVERNING AUTHORITIES. REQUIRE PERIODIC SERVICE. DOORS SHALL BE .OF 'THE SAME MATERIAL AS THE DUCT WORK AND CONSTRUCTED SO CONST 3. B. SOIL BEARING PRESSURE ASSUMED TO BE 2,000 PSF. AS TO MINIMIZE LEAKAGE. ALL C. ALL FOOTINGS TO REST ON UNDISTURBED SOIL. 12. HEATING & AIR CONDITIONING SYSTEM - HEATING AND AIR CONDITIONING SYSTEM SHALL BE COMPLETE WITH ALL YORKREQUIRE STAT PROPOSED YORK STATir T, D PROVIDE AL_L STEEL LINTELS, BOLTS, PLATES, GIRDERS AND FASTENERS AS REQUIRED. SHOP COAT ALL STEEL. NECESSARY COMPONENTS AND ITEMS NORMALLY SI)P'PLIED. SUBSTITUTIONS OF EQUIPMENT SHALL BE APPROVED BY BATHROOM E. STRUCTURAL STEEL SHALL COMPLY TO THE SPECIFICATIONS FOR DESIGN, FABRICATION AND CONSTRUCTION OF STEEL THE ARCHITECT, CONTRACTOR TO PROVIDE ONE YEAR FULL GUARANTEE OF COMPLETE SYSTEM. pE50QN C9R ADDITION rjl�Q�� ZONE FOR BUILDING OF THE A.I.S.C. ASTM A-572. 13. COMPLETION - AT THE COMPLETION OF THE WORD, ALL EQUIPMENT COMPLETE WITH THEIR FITTINGS SHALL BE s 7s b �a'�10-+ C�w1PLY WITH CHAPTER "46" F. ALL FRAMING AND CONNECTIONS SHALL BE IN ACCORDANCE WITH "HE LATEST EDITION OF THE NATIONAL DESIGN PROPERLY CLEANED AND LEFT IN FIRST CLASS WORKING CONDITION. ALL DUCT WORK SHALL BE LEFT CLEAN TO n A 6'S0, � SPECIFICATIONS FOR STRESS GRADED LUMBER AND ITS FASTENINGS AS PUBLISHED BY THE N.F.P.A. DESIGN BASED PREVENT SYSTEM DI` -FRIBUTION OF DUST AND DIRT. SYSTEM SHALL BE LEFT WITH CLEAN FILTERS. �VC��PAI"� Q ®�! E I OD DAMAGE PREVENTION v A R w,UTHOLD TOWN CODE. ON PRESCRIPTIVE DESIGN FORMAT AS PER THE WOOD FRAME CON.7iRUCTION MANUAL-HIGH WIND EDITION. 14. MANUALS - CONTRACTOR TO PROVIDE ALL PRODUCT LITERATURE, WARRANTEES, AND INSTRUCTION TO OWNER. f`' c � �. G. DOUBLE JOUST UNDER PARTITIONS WHICH RUN PARALLEL TO FLOOR JOISTS, AND AROUND OPENINGS. 15. CLEANUP - CONTRACTOR TO CLEAN UP AND DISPOSE OF DAILY, ALL HIS TRADE RELATED DEBRIS AND USE UIV LAWFUL ZOg�� z H. WOOD SILLS SHALL BE ACQ TREATED, .40 PCF, KDAT 15. PROVIDE: 1/2 INCH DIAMETER ANCHOR BOLTS AT 6 -0 O.C. WASTE MATERIALS. u ®9gyp C CATE PLUMBER CERTIFICATION I. PROVIDE RGOA\LVAN ZED CONNECTORS OFWIDE 2 BOLTS PER SILL E ALL CE M UITT STRUCTURAL MUM AND ECONI ECTIONOS ANOD TO MAINTAIN A CONTINUOUS LOAD PATH fRNERS MAX. WITH��UT �Eh i �r� CONTENT BEFORE FROM RIDGE TO FOUNDATION.. OF OC 'UPp�!CY ON LEAD J. CAULK OR IFOAM ALL EXTERIOR WALL PLATE AND SHEATHING OPENINGS, PENETRATIONS OF ELECTRICAL, PLUMBING, AND °'+ `/ ,pCERTIFICATE OF OCCUPANCY VENTING. -' , L TEMPORARY ATER PLUM A ^ SOLDER USED �M NNOT K. PROVIDE AL TEM OR RY RAILINGS AND SAFETY DEVICES FOR ALL TRADES DURING THE CONSTRUCTION OF THE �% SUPPLYS PROJECT. CA ALL PLUMBING'.vA 'TE &WATER LINES Ivy-D EXCEED 2110 OF 1% LEAD. L. CONTRACTOR TO DO ALL PATCHING NECESSARY TO REPAIR DAMAGE 'MADE DURING CONSTRUCTION ACTIVITIES. PATCHING TO TESTING BEFORE COVEPING MATCH AND MEET FLUSH UNLESS NOTED OTHERWISE. WARL)M. CONTRACTOR TO FIELD VERIFY ALL CONDITIONS AT THE SITE PRIOR-'TO CONSTRUCTION. /Abz5. UU1 ES , Paul N. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS SUPERSEDE SCALED DIMENSIONS. 0. ALL EXTERIOR NAILING SHALL BE STAINLESS STEEL OR HOT-DIPPED GALVANIZED. ARCHITE'1161.010, RD ff, '(1D FT RD ff, A IN ALL CONSTRUCTIONP. PROVIDE ONE ROW OF 5/4" X 3" WD. CROSS BRIDGING FOR EACH 8'-0" OF SPAN. LANDSCAPE ARCHITECTS, 1 w MEET THE REQUIRC, 1: THE Q. PROVIDE ACCESS DOORS IN HOUSE FRAMING TO ACCESS JACUZZI 'AND MECHANICAL EQUIPMENT. ENGINEERS CODES EN _ NOTE: INFC,'- 50' @ scale: 1 1500 LAKELAND AVENUE RMATION FOR THIS DWG. WAS TAKEN ,t)� FROM A S(IRVEY BY VAN TYUL & SON, L.S. N ,n DATED 10=24-72. BOHEMIA,, N ,, Y, 11716 12 5 R i" M A I N R p A D �v P E ARcy/ (631 ") ,563 4800 n UNDEpNPITERS CERTIFICATE fax (631 ) 563-4800 , � REQUIRED 15589 OF N F W I ��DDQ�D�iDTD� Ask VA EXISTING WALL TO REMAIN - - - - - - - EXISTING WALL TO BE REMOVED Z NEW INSULATED WOOD FRAME WALL v 5O"lU EXIST. LIVING ROOM N f ---= NEW UNINSUILATED WOOD FRAME WALL / �v REMOVE WALL AND CLOSET ��RIGHT OF WAY POOR AND FRAME. EXISTING D>OOR / c1y�' t NEW DOOR / / - EX. CL. EX. CL EX. CL. EXISTING CEILING FAN TO i LINE OF EXISTING (2) 2A2 FLUSH EXIST 1 STY REMAIN - PROTECT DURING HEADER ABOVE. SUPPORT AND FIR, DWLG. CONSTRUCTION. I I CONNECT. TO NEW (2) 1 3/4" x 11 L . — . — . � 71/8" M.L. (2.0) GIRDER 3 SUPPORTED ON 4x6 POSTS AT EA. END. PROPOSED / EXIST. GOLF DEN r EXIST. MSTR. 50RM. BATHROOM I L J w ADDITION REMOVE WALLS AND - - - - _ _ _ REMOVE WALL, FLOOR AND �0, LINEN CLOSET DOOR AND CEILING GYP. BIRD. / FINISHES, 7� 'lO«�� tct FRAME. EX. CL. ELECTRICAL PLUMBIN�c l6 ` EX. CL. I . FIXTURES AND FITTINGS. GAP �• o ,� �" PLUMBING IN CRAWL SPACE. seal: VkED qk cyy, 2 4x(o I 4x6 TEMPORARILY SUPPORT CEILINGG.>� AND ROOF FRAMING REMOVE � '" �•�' d07 EXTERIOR WALL AND WINDOW UNIT. 15 s .,. c} O CAP HEA'CING PIPING IN CRAWL SPACE. INSTALL Tyr 5 � ANDCLO ETDOOR AND DFRAMELL �OF NEW �� � . ! 4 llD D� QD P.Q. RD �� A . 71r 1 IlD 1� Ili PIl� � 1� �� IF �� Q� Q� �� IlD �� 1� i�T �� D+ �� Q� �� R . Pao � Q� i�T I Landscape Architects, 4Q A. 1 sale 1/4"=1'-0" Architects, Engineers A. 1 scale: 1" = 50' NOTE: INFORMATION FOR THIS DWG. WAS 0 TAKEN FROM A SURVEY BY VAN TYUL E SON, N m L.S. DATED 10-24-72. 1600 Lakeland Avenue Bohemia, N.Y. 11716 (631) 563-4800 45 West Main Street ' EXIST. LIVING Roots Little Falls, New York 11716 CLOSE EXISTING DOOR OPENING (315) 823-4384 I AND INSTALL NEW 48" 51FOLD DOORS AND STEM WALLS A5 project title: ` SHOWN. . PROPOSED NEW CL. BATHROOM EX. CL EX. CL. saP ADDITION for the EXISTING CEILING FAN TO RI 1�� WIDEN DOOR OPENING FOR NEW (o. WANKEL GORDON REMAIN - PROTECT DURING 2'I9" 2'-4" 2 "34 —'� PANEL FIR DOOR WITH MATCHING CONSTRUCTION. CA51NG AND CHROME RESIDENCE . — . HARDWARE. EXIST. GOLF DEN M)il'q � I , EXIST. MSTR. I=30RM. CUTCHOGUE, N,Y,CLOSE EXISTING WALL 2 lmdrawinEXIST.`GR-4UJL SP,4CE OPENINGS WITH NEW GYP. •� 4 g title. _ CONSTRUCT NEW LINEN SHELVES. . NOTE: BIRD. WALLS. 4'-0" HT. AND 18" DP: MARBLE VANITY UNIT VERIFY AND RELOCATE TILE FINISH IN LAV AREA. EX. CL. C.I EX. CL. WITH PIVOTING 48" MIRRORS. a OIL FILL AND VENT NEW MARBLE COUNTER WITH_ mar PIPING, EXTERIOR HOSE FULL IB" DEEP EDGE. RR - D v Pnn� n� v BIB, IRRIGATION HEADS WOOD FASCIA d BASE R ARI L ll ll1�dOU% AND PIPING AND SAWCUT NEW ACCESS CABINETS AND FULL WALL � a- ➢ ELECTRIC WALL HEATER OPENING AT EXISTING C. 05 REBARS AT 12" MIRROR AS SHOWN. 4x& ' '� 4x(0 W1/21N CRAWL SPACE, O.C. VERT AT NEW _ �-0QDuT�TD�1�P��llQ➢�T BLOCK WALL. P,ARGE / EXIST. WALL JAMJOIST.BS. REINFORCE BAND INTERSECTIONS _ -� — — — — GFI TYP. I s` W.C. REMOVE EXISTING SIDING IUp INSTALL NEW WONDER BOARD lye TILE UNDERLAYMENT. PROVIDE ------ ROTO 52V-13, 22" x4(.25" �•_ F 0 _ . WR GYP. BRD. AT PAINTED WALL 1 I VENTING SKYLIGHT WITH 7— . . — . . SURFACES. I ALL5EA50N-PLU5 LAMINATED,_ 0 _ B•e ( �x10F. J. I J I -a16" O. C. I i d ® x x10R — 2x10 - LOW-E ARGON FILLED � � �� 16 O. C.OVER I tr GLAZING (U=.24). REMOTE 0 m L 16" O— p 6' I TEMPERED GLASS NEO ANGLE a drawn by: checked by: MOTOR OPERATOR WITH RAIN ► ryl�- 8 ASTM C 90 I NEIU CRAUJL SP CE I \\ SENSOR SHOWER UNIT WITH GRANITE BASE CMU FOUNDATION I -(� I _ �•O I AND COFJyER SEAT. MULTI HEAD_ WALL W/ FILLED `� 7 ( �, 6l �- M - SHOWER UNIT AS SELECTED BY l date: SCGIe: F.V. 4'-0" x 4'-0" "DECORA° CORES. I 3 THICK GONG. SCREED ( 0 6" „ OWNER SLAB OVER (o MIL I � PATTERN GLASS BLOCK � Il-1�0 � (�� A- .4-29-03 AS NOTED VAPOR RETARDER I I' PANEL AT JAGUZZI TUB a" x 16" I i I I PLATFORM. 1 drawing number: FOUNDATION 11'-6" 8' I •�,- 8' 4" SQ. PORCELAIN TILE — CXWI35 — � - VENTS 1N GALV. I �r C O � ,J C� AREA WELLS — — — — — — — — — I JACUZZI TUB PLATFORM WITH LINE OF VENTED ROOF RAISED PANEL CHERRY ° OVERHANG AF30VE. FRONT AND 12" HEIGHT TILE J WALL SPLASH SURROUNDS AT 5/8" DIA. ANCHOR \ F.Y. BOLTS WITH LINE OF 10" x 20" THREE SIDES. 2-3 2-00 �2'-m" 2'-3" O o OF lip 11 3x3x3/Iro" WASHER FOOTING TO 2'-0" x 4'-0" "DECORA" PLATES AT 45" O.C. 5'-9" 11'-4" 5'-9° ALIGN WITH MAX. i EXISTING. PANEL8. RN GLASS BLOCK i 12'-10" ANYTHING ON THIS DRAWING AND/OR THE STATE LAW PROHIBITS ANY PERSON FROM ALTERING ACCOMPANYING SPECIFICATION. UNLESS IT n T1 n nn }� T n II n A IS UNDER THE DIRECTION OF A LICENSED 3 IlD 1� Il� Vfly 1� �d ll� QD �J N DD A "T R 0 IN llD I A 1VT D � P 9 d � T D D � � PROFESSIONAL. WHERE SUCH ALTERATIONS ll _ . •� n nn n p• n nn A �.. •� n 2 ll A T% ll R A ffj I 1Jd 0 0 D.% ll RA A f � R llD QD 11 QD 0 D4 DD ARE MADE THE LICENSED PROFESSIONAL MUST SIGN, SEAL, DATE AND DESCRIBE THE A. 1 scale 1/4"=1'-0" A. 1 scale 1/4"=V-0" DRAWING AND/OR FULL EXTENT OF THE THE 5 EC FICATION� ref. no.: 2003.08 LF DOUBLE MICROLAM RIDGE WITH SUPPORT POSTS IN WALLS DOWN TO LOWER HEADERS. PROVIDE CONSTRUCT NEW ROOF CRICKET COR-A-VENT RIDGE GALV. JOIST HANGERS AND RIDGE STRAPS AT I6" COR-A-VENT RIDGE AND BLEND NEW ADDITION ROOF O.C. TO MATCH AND ALIGN WITH EXISTING.. i • LINE OF ICE 4 WATER SHIELD UNDERLAYMENT. OPERA51,E 5KYL GHt �`��^ � 2x10 RAFTERS W/ R-30C INSULATION. _ LINE OF 18" WIDE LAYER OF ICE AND WATER SHIELD EITHER SIDE PROVIDE HURRICANE TIES AT EA. OF NEW VALLEY TYP. LIINE OF 8" HIGH STEPPED SHT. ;' `N` JOIST / PLATE CONNECTION. TYP. LINE OF 8" HIGH STEPPED 5HT. .'� _ _ NEW PREFINISHED CEDAR SIDING, _ MItL. FLASHING. MTL. FLASHING. .'� — FASCIA AND TRIM WITH DRIP CEDAR FASCIA - PREFINISHED WITH ; -�— EDGE TO MATCH AND ALIGN WITH DRIP EDGE AND ALUM. LEADER AND , — � EXISTING, GUTTER TO TIE INTO EXISTING. , ' I Y — — — — — - — — — — PREFINISHED CEDAR BEVEL NEW STORMWATCH SIDING WITH 3 1/2" CEDAR s S PRINGLINE A ND CASEMENT CORNER BOARDS t0 WINDOW UNITS WITH 3 1/2" LE R TILE F 00 OV ER P W MATCH EXISTING. .. CASING. MEMB NE ON 3/4 AZEK A ING. O PLYW D 6U B LR DECO RA P ERN TILE SURFACED TUB PLATFORM DE RA A T (2)2x6 CCA SILL PLATE WITH GLASS BLOCK AND 1"1ARBLE LAVATORY o0o TERM. SNLD, SILL SEALER SIDELIGHT UNITS WITH 3 seal: _ AREA5 WITH CHERRY FINISHED _ AND 5/8" A.B. AT 4'-0" O.C. W/ 1/2" AZEK CASING. �ERED q RAISI=D PANEL CABINET FACES e 3x3x3/16" SQ. WASHERS TYP. 4" P. iCONC. SLAB OVER 6 R-30 CE TER 8" TH. CONC. BLOCK FOUNDATION WALL CONC. BLOCK FOUNDATION WALL. MIL .V'APOR RETARDER ON B IDG G FILLED SOLID. PARGE ABOVE GRADE, ALUMINUM FOUNDATION VENTS UJItH — —— J —I POR0U5 FILL. WATERPROOF BELOW GRADE WITH SCREEN IN GALV. STEEL AREA WELLS. I PARGE ABOVE GRADE. WATERPROOF SELF-ApHEREING RUBBERIZED i BELOW GRADE WITH SELF-ADHEREING I STD 1558g �� RUBBERIZED BITUMINOUS MEMBRANE. BITUMINOUS MEMBRANE. I �,•• r�. �o Ofi NEW y - - - - -- - - - - - - - - - - - - - - - - - - - — — — — — — — — — — — — — — — — — — — — — — — - - - - - - - - - - - - - - - - - - - - - - - - - =I- - — - - - — I LINE OF 10" DP. x 20" WIDE P. CONC. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _ SAWCUT NEW 32" WIDE (3500 1=51. FOOTING WITH KEYWAY ACCESS OPENING INTO NEW CONT. LINE OF 10" DP, x 20" WIDE P. CONC. CRAWL SPACE. (3500 P51. ) FOOTING CONT. WARD ASSOCIAmsA WIN 4 'T T% 1-11. dq tam �; D 11a S 1J- Tay D9 QA 'T R 0 d V T % IT 'T N Landscape Architects, Architects, Engineers A. 2 �NOTE�FOP-�r-,45T�r=Nr=p-�5CHE�r-)UL-r=�AND�UfLIF�TONNECTION INFORMATION 5EE DRAWING A.3. scal�1/4-=V-7- .A 2 scale 1/4"=1'-0" 15M Lakeland Avenue Bohemia, N.Y. 11716 (631) 663-4800 45 West Main Street Little Falls, New York 11716 ( 823-1 4384 i 3 5) ' project title: LINE OF NEW ROOF CRICKET. BLEND INTO EXISTING ROOF. FULL ICE 4 WATER SHIELD UNDERLAYMENT. EXTEND 18" PAST PROPOSED VALLEYS. BATHROOM ADDITION for the COR-A-VENT RIDGE COR-A-VENT RIDGE WANKEL GORDON OPERABLE SKYLIGHT WITH RESIDENCE LAMINATED LOW-E INSULATED / GLASS. SEE PLAN FOR SPEC. i Ex I S T I T o REMAIN CUTCHOGUE, N,Y. / -- NEW ARCHITECTURAL ASPHALT 1NEW ARCHITECTURAL ASPHALT E X 15 T I N G TO REMAIN / \ SHINGLE ROOF - 30 YEAR ;SHINGLE ROOF - 30 YEAR I drawing title: WARRANTY. MATCH AND ALIGN IWARRANTY. MATCH AND ALIGN WITH EXISTING. WITH EXISTING. NEW PREFINISHED CEDAR SIDING, — vn d� ' FASCIA AND TRIM WITH DRIP ' vv v T EDGE TO MATCH AND ALIGN WITH PNEU1 PREFINISHED CEDAR SIDING, cc 11 In1 T� ; ':< :'>s?>?:::"'>:{i EXISTING. IFASCIA AND TRIM WITH DRIP a�11�Qa ll 11QD� IEDGE TO MATCH AND ALIGN WITH ................... . EXISTING. • NEW PREFINISHED CEDAR SIDING, FASCIA AND TRIM WITH DRIP EDGE TO MATCH AND ALIGN WITH EXISTING. drawn by: checked by: LMF 5G CONC. BLOCK FOUNDATION WALL. L CONC. BLOCK FOUNDATION WALL. date: =—— —1 scale: PARGE ABOVE GRADE. WATERPROOF I I I I I I BELOW GRADE WITH $ELF-ADHEREING PARGE ABOVE GRAPE. WATERPROOF BELOW GRAPE WITH SELF-ADHEREING I I �•-29-03 AS NOTED RUBBERIZED BITUMINOUS MEMBRANE. — — — — — — — — — — — — — — — — — - — — —I RUBBERIZED BITUMINOUS MEMBRANE. I — — _ — — _ _ _ _ drawing number: - - - - - - - - - - - - - - - - - - - - - - - - - - - - -1 - - - � E - - - - - - - -- - - - - - - --- - - - - - - - - - - - - - - - - -r - - - - LINE OF IPA" DP: x 20" WIDE P. CONC. LINE OF 10" DP. x 20" WIDE P. CONC. (3500 PSI. ) FOOTING CONT. (3500 PSI. ) FOOTING CONT. OF lld A PnV 1J9 I NJ V 1n1L IT R 0 IN r2fil 4 `� P 9 9 d j V V T�� �� �� �� 1� �� - STATE LAW PROHIBITS ANY PERSON FROM ALTERING ANYTHING ON THIS DRAWING AND/OR THE A. 2 scale 1/4"=1'-0" A. 2 ACCOMPANYING SPECIFICATION. UNLESS IT scale 1/4"=1'-0". IS UNDER THE DIRECTION OF A LICENSED PROFESSIONAL. WHERE SUCH ALTERATIONS ARE MADE THE LICENSED PROFESSIONAL MUST SIGN, SEAL, DATE AND DESCRIBE THE FULL EXTENT OF THE ALTERATION ON THE DRAWING AND/OR IN THE SPECIFICATION. ref, no.: 2003.08 LF I 01 HE 13 D U I I9 UNIT DESCRIPTION ROUGH OPENING SIZE OPG. WIDTH OPG. HEIGHT EGRESS AREA UNIT AREA MANUFACTURER REMARKS CXWI5 SINGLE CASEMENT 3'-0 1/2" W x 5'-0 3/8"H. 30 1/8" 55" 9.4 S.F. 14.9 S.F. ANDERSEN "STORI` ATCH"UNIT,ExT JAMBS,SCREEN GRILLS AND OBSCURE GLAZING. 5E311 5[=RINGLINE WINDOW 3'-1 1/211" W x 2'--1 1/4" H. - - - 5.10 S.F. ANDERSEN "STORMWATCH"UNIT,EXT JAMBS,SCREEN _. GRILLS AND OBSCURE GLAZING. ILi4IL Elk QAy '111A0]DIL QAQDINIlD1RAINQAIL NOTE: THE PROPOSED BUILDING ADDITION REPRESENTED BY THESE PLANS HAS BEEN DESIGNED TO MEET THE NEW YORK STATE ENERGY CONSERVATION CONSTRUCTION CODE REQUIREMENTS VERIFIED BY THE USE OF RESCHECK WITH THE FOLLOWIRG RESULTS: MAXIMUM UA=48 / PROVIDED UA=43 MAX. CODE GLAZING U=.37 / GLAZING U=.34 TABLE 502.2.4(4 ) 18 % WINDOW. AREA i HEATING DEGREE DAYS: 5750 GLAZING U FACTOR: CEILING R-VALUE: ROOF 4" V.T.R. NOTE: _ __ CODE: .37 CODE: .38 - PROVIDE GALVANIZED ACTUAL: .34 ACTUAL: .30 � 3��X4�� INCREASER SIMPSON STRONG-TIEI ' EXTERIOR WALL R-WALUE: I seal: W LSTA 18 STRAP TIE AT FLOOR R-VALUE: AO ---}- RIDGE CONNECTIONS 19 TYP.0055 CODE: 19 �� # ACTUAL: 1 �� �� �� E m. TENSION). ACTUAL: 30 CONNECTION NOT SHOWN. 11/2 �3 2 I I/2 �`��c FF�\ o,, SLAB PERIMETER R--•VALUE / DEPTH: BASEMENT WALL R-VALUE: LAVLAV �' CODE: 9, 21"T'. CODE: 10 TUB WC. 51 ET ACTUAL: N/A ACTUAL: N/A FIRST FLOOR SHWR. \ : CRAWL SPACE WALL, R-VALUE: CO 4" 2" s 1 9 CODE: 19 2" 3�� 3„ 411 t C.O. �5s ACTUAL: N/A QA 0 �D E- 9 IL Off QA 7l QA If% R IT Da Ifu R A CONNECT TO EX15TING SANITARY PIPING SYSTEM IN CRAWL SPACE BELOW LIALVANIZED SIMPSON 5TRONG�-TIE H3 GROUND SNOW LOAD: 45 PSF (F301 .2(5)) HURRICANE LIES, IS CxA. FLOOR LIVE LOAD: 40 PSF (BEDROOMS, DECKS AND STAIRS) (R301.4) CRAWL SPACE W/ (4) 8d AT EACH JOIST 30 PSF (OTHER THAN SLEEPING) - AND (4) 8d AT TOP 60 PSF (EXTERIOR BALCONIES) NrES PLATE. TYPICAL AT FOR 20 PSF (ATTICS WITH STORAGE) EACH JOIST / TOP 10 PSF (ATTICS WITHOUT STORAGE) �� Landscape Architects, i PLATE CONNECTION. 30 PSF (OTHER THAN SLEEPING) IIDIl.��Jid����1DTQ� Il����� DD�I�QAIl�I���� Architects, Engineers (455# UPLIFT) _ !. NOTE: AT CORNER 6l ROOF LIVE LOAD: 16 PSF MIN. (R301 .5) COLUMNS PROVIDE e BASIC WIND SPEED: 120 MPH (F301 .2(4)) A. 3 N.T.S. 1500 Lakeland Avenue rgALVANIZED STRONG TIE SEISMIC DESIGN CATEGORY': C ( AS DETERMINED BY CODE OFFICIAL) (F301 .2(2)) Bohemia, N.Y. 11716 ECCQ COLUMN CAP ° (CORNER UNITS. WEATHERING PROBABILITY: SEVERE (R301 .2(3)) (631) �-48� TERMITE PROBABILITY: MODERATE TO HEAVY (R301 .2(6)) DECAY PROBABILITY: SLIGHT TO MODERATE (R301.2(7)) 45 West Main Street Little Falls, New York 11716 ' WINTER DRY-BULB TE11; 1 1 DEGREES F (TAB. N1 101 .2) (315) 823-4384 DECAY PROBABILITY: SLIGHT TO MODERATE TOP PLATE TOP PLATE ., LATERAL CONNECTION LATERAL CONNECTION project title: SECTIONAL VIEW END VIEW C�A!_V. SIMPSON STRONG PROPOSED PROPOSED TIE MODEL MSTA30, 18 BATHROOM GA. STRAP TIES AT 16" O.C. WITH ((o) Sd FASTENENERS INTO STUDS I EXTENSION AND (8) Sd FASTENERS ° I for the INTO BAND JOISTS. (800# gi WANKEL / GORDON UPLIFT) � �' ' FAA SCMIDUM FOR STRUICT�L MS CFCM Table 301) GENERAL NOTES RESIDENCE NOTE: AT CORNER COLUMNS PROVIDE NUMBMANDTYPE GALVANIZED STRONG TIE DESCRIP11ONOFBUIILDINGIIIEMB19TS OFFAS ENM SPAC•INOOFFASTENER 1. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE 11HD5A (3105# UPLIFT) JOIST TO SRL OR GIRDER,TOE NAIG 4gd perjoist SITE PRIOR TO COMMENCING CONSTRUCTION. 1"x6"SUBFLOORORLESSTOEACH JOIST,FACE NAIL 28d per support 2. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS SUPERSEDE SCALED CUTCHOGUE, N.Y. SILL PLATE SILL PLATE 1m •.. a 2"SUBFLOORTO JOIST OR GIRDER,BLMD AND FACE NAIL 16d Wedge/6"field DIMENSIONS. LATERAL CONNECTION LATERAL CONNECTION Ih .. SOLE PLATE TO JOIST OR BLOCKING,IFACE NAIL 2-16d per foot 3. ALL WORK SHALL CONFORM TO THE RESIDENTIAL CODE AND THE drawing title: SECTI%AL VIEW END VIEW I�� TOP OR SOLE PLA' ETO STUD,ENEDNAUL 3-16d per 2x6stud ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE, THE a STUD TOSOL.E PLATE,TOE NAIL _ 3-16d per 2x6stud NATIONAL ELECTRIC CODE AND THOSE OF THE LOCAL JURISTICTION. NOTE:FOR FASTENER SIZES AND QUANTITIES SEE FASTENER SCHEDULE THIS DRAWING. WITH SILL SILL PLATES d DOUBLE STUDS,FACE NAIL 2-16d 24"ox. 4. ALL FOOTINGS SHALL BEAR ON UNDISTURBED SOIL HAVING A BEARING 11D1J�Pll�1-11�1J�Ia�9 DOUBLE TOP PLATES,FACE NAIL 2-16d 12' ox. CAPACITY OF AT LEAST 1 TON PER SQUARE FOOT AND SHALL HAVE A SHLD. AND 5/8" A.B. At SOLE MATE TO JOIST ORBLOCMCiAf�TBRACEDWALLPANEIS 2-16d* 12"o.c. MINIMUM COVER OF 3 FEET BELOW GRADE. y q y y y ,� „ - 6)QA���9�D�JIl��9 g9 48 O.C. WITH 3 SQ, x Ia u v a DOUBLIETOPPLATES,IYIINIMUM48.191CH OFFSET OF END JOISTS, 8-16d 5. STRUCTURAL LUMBER SHALL BE DOUG. FIR #1, Fb = 1000 psi. base 9/1(o G�cALV. WASHER FACE NAIL IN LAPPED AREA E=1,700,000 PSI; NONBEARING LUMBER SHALL BE HEM-FIR#2 WITH Fb �- PLATES SIMPSON STRONG '4 BLOCMNGBEt'VHF.EN JOISTS ORRAF[7ElE3STO TOP PLATE,MENAIL 2-8d each end = 850 psi. (base), E = 1,300,000 psi. TIE #LP551/2 TYP. d e RIE�IJOIST TOTOIPPL.ATE,TOE NAIL, 2-16d* 12"o.c. 6. STRUCTURAL STEEL' SHALL BE ASTM A-572, DETAILED, FABRICATED D HIKING �T q I yn� 1 TOP PLATO,LAPS AT CORNERS AND WfERSEC IONS,FACE NAIL 4-16d joints-each side AND ERECTED IN ACCORDANCE WITH THE AISC. R HOU, �11D�1VQA ����1J4�Zl BUILT-UP HEADER,TWO PIECES WnH1 1/2"SPACER 16d 16"o.c.along edges 7. ALL HEADERS SHALL BE SUPPORTED ON 4x4 POSTS MIN. UNLESS CONTMEDHEADER,TWOPIECES, 16d 16"o.c.alongedges NOTED OTHERWISE ON THE DRAWINGS. 1JD111-1L `All�1`"dVll q- 1A.P.O.�����1��� A10T�� UTTARV Pn� �� ����� 11d VT�� �11d VT�T�a�11IP�� d VTAY CF�LINGJOIS7fSTOPLATB,T®IE�IAL(. 3fid(4>3d) S'0"wau(10'wau)-acetaale3.3A ll 8. PROVIDE DOUBLE HEADERS AND TRIMMERS AT ALL FLOOR, STAIR AND CONTINUOUS HEADER TO STUD,TOE iNAIL 4-8d ROOF OPENINGS AND UNDER ALL POSTS AND PARTITIONS RUNNING CEILING JOIST,LAPS OVER PARTIT'Im s,FACE NAIL 8-16d (see table 3.7)each lap PARALLEL TO SAME. A. S C d I E, 3/4" = 1'-0" CEHJ NG JOIST'TO PARALLEL RAFDRS,FACE NAIL 8-16d ( )(we g, ALL HEADERS LESS THAN 5'-O" SPAN SHALL BE 2 2x10 RAPTERTO PLATE,TOE NAIL 3-8d (see table 3.3a)per rafter UNLESS NOTED OTHERWISE. 1"BRACE TO EACH STUD AND PLAATIi,FACE NAIL 2-16d, per foot 10. PROVIDE SOLID OR 5/4" x 3" CROSS BRIDGING AT 8'-0" MAX. drawn by: checked by: 11. PROVIDE GALV. FRAMING CONNECTORS AT ALL BUTT STRUCTURAL �r�� CJC'✓ 1"x6"SHEATIIINGTO EACH BEARING,,FACE NAIL 2-8d per support CONNECTIONS AND. H3 HURRICANE TIES AT TOP PLATE TO ROOF FRAMING CONNECTIONS. 1"x 8"SHEATHIING TO EACH BEARING;,FACE NAM 2-W date: i p�$uPP� 12. PROVIDE HARD WIRED SMOKE DETECTORS AT EACH FLOOR LEVEL AND IN Scale. ALL BEDROOMS, AND AS REQUIRED BY CODE AND THE LOCAL 4-29-03 A5 NOTED WIDER THANI"x8"SHEATHINGTOEACH BEARING,FACE NAEL 3-8d per support AUTHORITIES. PROVIDE A CARBON MONOXIDE DETECTOR AT EACH FLOOR LEVEL, drawing number: BUILT-UP CORNER STUDS 2-16d 24"o.c. 13. CONTRACTOR SHALL DO ALL PATCHING REQUIRED DUE TO NEW WORK BUILT-UPGIIBDL'JRS ARIDBEAFiIS,2INCfIlLUMBERLAYEIBS 16d 16"ox.alongedges AND / OR REMOVAL OF EXISTING. ALL PATCHING SHALL MEET FLUSH 2"PIlANICS 2-16d at each supportAND MATCH EXISTING CONSTRUCTION UNLESS NOTED OTHERWISE. IvoOFRA} EI TrD'lv1�E'�IALiEym[�aIpRAI�rERS'TOENAIL 14. UNLESS NOTED OTHERWISE, ALL WINDOW DESIGNATIONS SHOWN ARE �J FACE `l1� THOSE OF THE ANDERSEN CORPORATION. UNITS TO HAVE WIND BORNE O FACE NA,II. 3-16d DEBRIS RESISTANT GLAZING "STORMWATCH" (MISSLE D-ASTM E 1996)) RAnEATIBSTORAFI'ERS,FACE 4-8d (see table 3.6a)each tie WITH LOW E COATING, EXTENSION JAMBS, SCREENS. GRILLES AS A . Q )) OF WOOD sTR UCPURAL PANELS,SUBFLOOR,ROOF AND WALL SHEATHING TO FRAMMING,AND SHOWN 0 N DRAWINGS. PARTICLEBOARD WALL SHEATHING TO FRAMING(weTable3.9) 15° CCA OR ACQ TRTD. WOOD SILLS SHALL BE (2) 2x6 WITH 1/2" DIA. 5/16-1/2 8dCOMMOININ NAIL(SUBFLOOR,WALL) 6 12"o.a(6"o.c.at4'Edge Zones) ANCHOR BOLTS SPACED 4'-0" O.C. MAX. PROVIDE 2 BOLTS WITH 3" 8dCOMMOINNAII.(ROGE� SQ. X 3 16" WASHERS PER SILL SECTION MINIMUM. PLACE BOLTS 19/32-1 8d COIMR,II®lly NAIIL, 6 12"o.o.(6"o.c.at 4'Edge Zones) � „ WITHIN 1 -0 OF ALL CORNERS. INSTALL OVER SILL SEALER AND 11/8-1114 10dCOA�IMON NAIL OR 6 12"ox.(6"ox.at 4'Edge Zones) TERMITE SHIELD (TYPICAL). STATE LAW PROHIBITS ANY PERSON FROM ALTERING ffidDEFOR.b�DN`4II. ANYTHING ON THIS DRAWING AND/OR THE 16. CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF ACCOMPANYING SPECIFICATION. UNLESS IT *NOTE:NAIL.INGREQUIREMEM ARE BASED ON WALL SHEATHING NAILED 6"ox.AT THE PANEL EDGE.IF WALLSHEAT�IGIS NAILED 3"ox. 3000 PSI (3500 PSI FOR EXTERIOR EXPOSURES). A UNDER THE DIRECTION OF A LICENSED AT THE PANEL EDGE TO OBTAIN H1G MR SHEAR CAPACITIES,NAILING REQUIREMENTS FOR STRUCTURAL MEMBERS SHALL BE DOUBLED,OR ALTERNATECONNIECPORS,SUCH AS SHEAR PL.ATE.SSHALL BE USED ToMAINTAIFITILE LOAD PAnL PROFESSIONAL.' WHERE SUCH ALTERATIONS ARE MADE THE LICENSED PROFESSIONAL MUST SIGN, SEAL, DATE AND DESCRIBE THE FULL EXTENT OF THE ALTERATION ON THE DRAWING AND/OR IN THE SPECIFICATION. ref. no,: 2003. 15LF x