Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
37314-Z
�o uF� cp Town of Southold Annex 3/11/2013 �O riy P.O.Box 1179 y - 54375 Main Road oy Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 36164 Date: 3/11/2013 THIS CERTIFIES that the building RESIDENTIAL ALTERATION Location of Property: 290 Richmond Ln, Peconic, SCTM#: 473889 Sec/Block/Lot: 86,14.8 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 6/4/2012 pursuant to which Building Permit No. 37314 dated 6/21/2012 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: alter an existing attic area to living space as applied for. The certificate is issued to Brett, Jason&Brett,Elise (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 37314 12/13/12 PLUMBERS CERTIFICATION DATED 3/3/13 Gecarge J Berry, Jr Autho Signature ASV ot�c TOWN OF SOUTHOLD BUILDING DEPARTMENT y TOWN CLERK'S OFFICE ' . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE.WORK AUTHORIZED) Permit#: 37314 Date: 6/21/2012 Permission is hereby granted to: Brett, Jason & Brett, Elise 370 E 76th St New York, NY 10021 To: alter an existing attic area as applied for At premises located at: 290 Richmond Ln, Peconic SCTM # 473889 Sec/Block/Lot# 86.-1-4.8 Pursuant to application dated 6/4/2012 and approved 'by the Building Inspector. To expire on 12/21/2013. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $348.40 CO -ALTERATION TO DWELLING $50.00 Total: $398.40 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval frorn Health Dept. of water supply and sewerage-disposal (S-9 forin). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in systern contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed.site plan requirements. B. For existing buiiali::gs (prior to April 9, 19571 non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. if a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy -New dwelling$50.00, Additions to dwelling$50.00, Alterations to dwelling$50.00, Swimming pool $50.00, Accessory building$50.00, Additions to accessory building$50.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy- $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 Date. 0 ;L New Construction: Old or. re-existing B ilding: (check one) Location of Property: 23 C) 1,c Al 00 117 P, C 0 L4 G. House No. Street Hamlet Owner or Owners of Property: :OAS014 qy� Suffolk County Tax Map No 1000, Section Block 1 Lot Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant:;ygs0" 4 Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: ' Temporary Certificate Final Certificate: (check one) Fee Submitted: $ b Applicant Signature pF SO(/r�ol Town Hall Annex ~ Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 roger.richert(a)-town.southold.nV.us Southold,NY 11971-0959 couff `I,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Jason Brett Address: 290 Richmond La City: Peconic St: NY Zip: 11958 Building Permit#: 37314 Section: Block: Lot: WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: DBA: RJ Cora=ini Electric License No: 33419-me SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor X Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 8 Ceiling Fixtures 3 HID Fixtures Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures Smoke Detectors 1 Main Panel A/C Condenser Single Recpt Recessed Fixtures 8 CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches F6 Twist Lock Exit Fixtures 11 TVSS Other Equipment: 1-exhaust fan Notes: Inspector Signature: ,vim Date: Dec 13 2012 81-Cert Electrical Compliance Form.xls l O Ca Town Hall,53095-Main Road . Fax(631)765-4502 P.O.Box 1179 �Od ®� Telephone(631)765-1802 Southold,New York 11971-0959 BUILDING DEPARTMENT TOWN OF SOU MOLD CERTIFICATION Date: Building Permit No. Owner: (please print) MAR -8 24�3 Plumber: �'�Du'`4 .�S(please print) BLDG. DEPT. TOWN OF SOUTHOLD I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. (Plumbers S ature) Sworn to before me this do f &e , 201 V1f:Kt t.110PER NetaryAbI;, State-of New York �CB � NOAR06070081 Qualif<Qd in Suffolk ounty CM.04sion expires � County Notary Publie, r� b pF SOUry�lo TOWN. OF SOUTH OLD O BUILDING DEPT. 765-1802 INSPECTION . [ ] FOUNDATION 1ST [ . ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION �qELECTRICAL FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) (FINAL) REMARKS: DATE 2' C- INSPECTOR pF SO(/r�o o TOWN OF SOUTHOLD BUILDING DEPT. '. 765-1802 INSPEC ION :. . [ ] FOUNDATION 1ST ROUGH PLBG. . [/, FRRAMING UNDATION 2ND [ ] INSULATION/STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS.-- DATE INSPECTOR v OF SOUryO� . TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION �] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: DATE z.. INSPECTOR ` OlyCo�'� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION' . ' .' . [ ] FOUNDATION 1 ST [ ] ROUG LBG. [ ] FOUNDATION 2ND [ SULATION [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: DATE 1 INSPECTOR OF SOUTyo� • ao TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION : . ' .. . [ ] FOUNDATION i ST [ ] ROUGH PLOG. [ ] FOUNDATION 2ND [ ] INSULA [ ] FRAMING/STRAPPING [ NAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: DATE INSPECTOR FIELD INSPE�ON REPORT DATE COMMENTS FOUNDATION(1ST) � r� FOUNDATION(M) 7A� • z o ROUGH FRAAMW& - y PLUMBING S INSULATION PER N.Y. H STATE ENERGY CODE .mac_ � -•- FINAL OA ADDITIONAL COMMENTS 0 .00 � z TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. �� ��4 Check Septic Form N.Y.S.D.E.C. Trustees C.O. Application Flood Permit Examined 20__,R- Single& Separate Storm-Water Assessment Form CContact: Approved 20 [RE 0Mail to: �Q'Sytq ,�V-c-j�1 Disapproved a/c JUN 4 2012 �3-20 E 76-ekS-t.#C_20 ' Phone: Expiration 200— BLDG.DEPT. -�'�s ofasce1� TOWN OF OL Buil ing Inspector APPLICATION FOR BUILDING PERMIT Date , 2010� INSTRUCTIONS a. This application MUST be completely filled in'by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according,to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or-in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition sik months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. Signature of a plicant or name, if a corporation) (Mai g lin addres of applicant) /o.0 State whetierAappli 'ai3t is ocn�r3er*blesee;vagent, architect, engineer, general contractor, electrician, plumber or builder a,i;�a • ,gin. •:,,�.-:,C� ,�i � ,!t� ;� Name of owner-of premises �_J-gsol a- rAse- dreiZt (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporat offc r) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of and on which pr p sed work will bePC ne. V C, o C yr House Number Street Hamlet County Tax Map No. 1000 Section Block 1 Lot Subdivision Filed Map No. Lot O 2. State existing use and occupancy of premises aid intend--' use and occupancy of proposed construction: a. Existing use and occupancy Y ''s- ` b. Intended use and occupancy y'Csi-d W 3. Nature of work (check which applicable): New Building Addition Alteration ✓ Repair Removal Demolition Other Work k l`P (Description) 4. Estimated Cost Fee7 o (To be paid on filing tl a plication) 5. If dwelling, number of dwelling units Numbed o:f,dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy 'specify ur anddo ent olf each type of use. �✓/� t 7. Dimensions of existing,structures, if any: Fr'ontr^� �a_ _Real Depth"'-�7 Height ti a-2,O Number of Stories Dimensions of same structure with alterations or additions: Front `'`'LT �� Rear - Depth Height D Number of Stories 8. Dimensions of e tire new construction: Front 1✓kl+ Rear - Depth Height Number of Stories 9. Size of lot: Front I Z-lr :f 6 Rear Depth 10. Date of Purchase I%e6eV Q 200 Name of Former Owner Scl e1ML -,, W CS, KC. 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zor 'ng law, ordiriance or regulation? YES NO ✓ 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO 14. Names of Owner of prime �iXs�aS �� ` y�2 " ddress�ggO 9( *1-oti hone No.v ct 2 Address so u!a S Phone NoName of Architect CS` Vey` 6 y Name of Contractor �` Q ` Address 101 60X / g Phone No. ��— �G 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE3EQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO y/ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. PAUL STUTZ STATE OF NEW YORK) Notary P,uv!Ic - State of New York NO.01 ST616014.4 SS: Qualified In Queens Cp t COUNTY OF=S� C,u�,l� y Y ) My Commission Expires t gsaW Vr&k J being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Swq n to b fore me this .S � - � day of I A 20 1Z,, Notary Public Signature-of App K&r Yt Town . of Southold N - Erosion, Sedimentation & Storm-Water Run-off ASSESSMENT FORM PROPERTY LOCATION: S.C.T.M.#: 7.3�q � � ( DTHE FOLLOWING ACTIONS MAY REQUIRE THE SUBMISSION OF A� STORM-WATER,GRADING, RA IN AGE AND EROSION CONTROL PLAN "6lsfrict Section ck. T-' CERTIFIED BY A DESIGN PROFESSIONAL IN THE STATE OF NEW YORK. SCOPE OF WORK - PROPOSED CONSTRUCTION ITEM# / WORK ASSESSMFdV'I' Yes No a. What is the Total Area of the Project Parcels? I Will this Project Retain All Storm-Water Run-Off(Include Total Area of all Parcels located within 7 the Scope of Work for Proposed Construction) 90 Generated by a Two(2")Inch Rainfall on Site? . b. What is the Total Area of Land Clearin (S.F./Acres) (This item will include all run-off created by site —✓ El9 clearing and/or construction activities as well as all and/or Ground Disturbance for the proposed © Site Improvements and'the permanent creation of construction activity? (S.F./Acres) impervious surfaces.) PROVIDE BRIEF PROJECT DESCRIPTION (Provide Add tional Pages as Needed) 2 Does the Site Plan and/or Survey Show All Proposed Drainage Structures Indicating Size&Location?This Item shall include all Proposed Grade Changes and C 6 veV'J� /SX e Slopes Controlling Surface Water Flow. L Zs 3 Does the Site Plan and/or Survey describe the erosion and sediment control practices that will be used to control site erosion and storm water discharges. This 'Ola- 1,— > item must be maintained throughout the Entire Construction Period. 4 Will this Project Require.any Land Filling,Grading or / Excavation where there is a change to the Natural El _]L Existing Grade Involving more than 200 Cubic Yards of Material wfthin any Parcel? 5 Will this Application Require Land Disturbing Activities Encompassing an Area in Excess of Five Thousand (5,000'S.F.)Square Feet of Ground.Surface? '- 6 .Is there a Natural Water Course Running through the General DEC SWPPP Requirements: / Site? Is this Project within the Trustees jurisdiction ❑ V/ or within One Hundred(100')feet of a Welland or Submission of a SWPPP is required for all Construction activities involving soil Beach? disturbances of one(1')or more acres;including disturbances of less than one acre that 7 Wilt there be Site preparation on Existing Grade Slopes are part of a larger.common plan that will ultimately disturb one or more acres of land; which Exceed Fifteen preparation feet n Vertical Rise to including Construction activities Involving soil disturbances of less than one(1)acre where One Hundred(10 Fifteen Of 15)feet of.DiStanCe? the DEC has determined that a SPDES permit is required for storm water discharges. (SWPP.P's Shall meet the Minimum Requirements of the SPDES General Permit 8 Will Driveways,Parking Areas or other Impervious for Storm Water Discharges from Construction activity-Permit No.GP-0-10-001.) Surfaces be Sloped to Direct StomrWater Run-Off D �, 1.The SWPPP shall be prepared prior to the submittal of the NOL The NOI shall be into and/or in the direction Of a Town right y?-of-Wa submitted to the Department prior to the commencement of constriction activity. j 2.The SWPPP shall describe the erosion and-sediment control practices and where 9 Will this Project Require-the Placement of Material, / required,post-construction storm water management practices that will be used and/or Removal of Vegetation and/or the Construction of any constructed to reduce the pollutants in storm water discharges and to assure Item Within the Town Right-of-Way or Road Shoulder compliance with the terms and conditions of this permit.In addition,the SWPPP shall Area?(This item will NOT Include the installation of Identify potential sources of pollution which may reasonably be expected to affect the DfireuiayAprons.) quality of storm water discharges. NOTE: If Any Answer to Questions One through Nine is Answered with a Check Mark 3.All SWPPPs'that require the post-constriction storm water management practice in a Box and the construction site disturbance is between 5,000 S.F.&1 Acre In area, component shall be'prepared by a qualified Design Professional Licensed in New York a Storrs-Water,Grading,Drainage&Erosion Control Plan is Required by the Town of that is kngwledgeabre in the principles and practices of Storm Water Management. Southold and Must be Submitted for Review Prior to Issuance of Any Building Permit (NOTE A Chedr Mark(,J)and/or Answer for each Question Is Required for a Complete Appffcation) STATE OF NEW YORK, COUNTY OF.. i( SS � � yYV - Notary Pua!Ic - Sfcte of New York NO.01 ST616014 4 lfiat I Q S D 1� y`Z Qualified.In Queens County I . .. Document) being duly sworn,deposes and says, lil� l4611�fb�)i±�tt poi Perml�� 1 (Name of individual signing Document) And that he/she is the .............................. �. .. (Ovmer,Coritrector,Agerit.Corporate Officer,etc).• ..••... .. •.. ..•..........•.....•.••.••.•... Owner and/or representative of the Owner or Owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all staternents contained in this application are true to the best of-his knowledge and belief;and that the work will be performed in the manner set forth in the application filed herewith. Sworn to before me this; ................ ..l.�.............day 1............. ... 'Notary Public_ .......... .... ... .... . ..... ................................ ... . . . .. . ... . ..... (Signature of Applicant) FORM - 06/10 stun$ 4, lsTkR�UB �_ NTC NTIO F, =1 Z)ESIGWSATO.R.K.S • ARCHITECTURE PC June 20, 2012 Building Department Town Hall Annex Building 54375 Route 25 P.O.Box 1179 Southold NY:11971. RE: Proposed Application for Building Permit Brett Residence 290 Richmond Lane Peconic; New York; 1,1958 To whom it may concern, This letter is to certifVAhat upon completion of the-proposed renovation.the house will have a maximum total use of four(4) bedrooms. The'existing window in the.proposed:study meets requirements of the 20.10 NYSBuilding Code, per the following: Section 1026 Emergency Escape;and Rescue 1026.2 Minimum size.Emergency escape and,rescue openings shall have a minimum net clear opening of.5.7 square feet.(0:53'ni). The existing window is a double hung window 11.5 sq ft in size;the clear opening of the lower portion is 5.75 sq feet. 1026.3 Maximum height.from floor.Emergency escape and rescue openings shall have the. bottom of the clear opening,'not greater than 44:inches.(1118 mm)measured from the floor. Existing bottom of opening is 33-inches 1626.4 Operational constraints.Emergency escape and rescue openings shall be operational from the inside'of the room without the-use of keys or tools. Compliant 1 50 WEST 2B'" STREET, SUITE 1.5038,'TVEW'YORK, NY iaboi • T: ,646.502.B655 F: 917.210.4287 INFO BD.WARCH.CDM'• WWW.HARTON'DESIGNWORKS.Com {TEq Ni3S I _ 1NTE NTIp nES'rGN'W'ORKS • 'ARCNITECTURE PC Sectional 1203 Ventilation 1203.4 Natural ventilation. Natural ventilation of,an occupied space shall be through windows,doors,louvers or other openings to the outdoors.The operating mechanism for such openings shall be provided with-ready access so that the openings are readily controllable by the building occupants. Compliant SECTION 1205 LIGHTING 1205.1 General.Every,space intended for human occupancy shall be provided with natural light by means of exterior.,glazed openings in accordance.with Section 1205-.2 or shall:be provided with,artificial li&Vin accordance with Section 1205.3'.Exterior glazed openings shall open directly onto a public way or onto"a yard or court in accordance with Section 1206. 1205.3 Artificial tight.Artificial light shall berprovided that is adequate to provide an average illumination of 10 foot-candies-(101 lux)over the area of the room at a height of 30 inches (762 mm) above-the floor level Please see the attached lighting calculation which illustrates the required foot candle level of 13 fc at 30 inches. T ank you iA tein,AIA . . �6so4 � Principal OF 1 5D WEST '2a'" .STR.EEX, SU'IYE 1 503 8, NEW YORK, NY 10001 • T: 54S.SO2.B655 F: 91 7.21 0.42B7 INFO EMVD ARCH.COM i www.BARTONDE9IGNW0R15S.00M Settings Calculation Results [B] Units Fe }•Foatcandtes luumfnance 13 fc Power Density 0.55 Wlft= Room Dimensions quantity 3 Length[X] 23.6 ft Sparing Results [B] width(Y) 9,5 ft Spacing 7.8 x 9.5 ft Hetghi[Z] 4.5 ft Arrangement 3 x 1 Workaana 2.5: ft 7 t3 Outside Spacing X 3.75 ft CeRing Type Open .; _... - ......... .. ,.__ ..,.. ._ 1 Outside Spacing Y 4.5 ft Room Reflectances Camparison. Ceiiing 80 - rs l.uminaire PC WlFI': Count VMS 513, 5 I A 11 0.34 3 Floor 20 1E"J - (,� Q ,Q J B 13 0.55 3 Criteria _ = Display lEturrina:rice 10; fc (k, Power Density Lwftt% gian[Ity 21.£ Hide Zonal Cavity Info[-) Constraints Coefficient of Utilization 0.26 Spacing X ft Floor Cavity Spacing't _...•. : ft Height 2.5 ft ROWS 1 Cavity Ratio 1.85 cdurnns 3 Form Factor 0.71 Effective Reflectance 19.6 Room Cavity Height 7 ft Cavity Ratio 5.17 Form Factor 0.4 Ceiling Cavity Height 0 ft Cavity Ratio 0 Form Factor 1 Effective Reflectance g0 Brett Residence � o Town Hall Annex Telephone(631)765-1802 54375 Main Road roger.ndhedw ouP.o.Box 1179 QZ C �o` nsthold ny us Southold,NY 11971-0959 BUILDING DEFARTAW" TOWN OF SOUMOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Oj>i �J ��.9 2 Date: - 7- /�- Company Name: Name: License No.: Address: Phone No.: JOBSITE INFORMATION_ (*Indicates required information) *Name: *Address: *Cross Street: SLlo�e *Phone No.: Permit No.: Veil Tax-Map District: 1000 Section. Block: - Lot: *BRIEF DESCRIPTION OF WORK (Please Print Clearly) A (Please Circle All That Apply) *is job ready for inspection: YE NO Rough In Final *Do you need a Temp Certificate: YES Temp Information(If needed) *Service Size: 1 Phase .3Phase 100 150 200 300 350 400 Other *New Service: Re-co nect�Underground Number of Meters Change of Service Overhead i Additional Information: U I-L (,G r A DUE WITH APPLICATION BLDG.DEPT. .82=Request for Inspection F TOWN OF SOUTHOLD �� PLOT PLAN OF LOT 8 MAP OF RICHMOND SHORES AT PECONIC FILE No. 6873 FILED NOVEMBER 20. 1979 SITUATED Ar PECONIC TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK S.C. TAX No. 1000-86-01-4.8 SCALE I"=40' MAY 24, 2000 JUL% 24. 21100 PEVk",L[- WATEP 'ARVI,E Lie L=41.01' AREA 22,391-28 sq. fl. 0.514 cc. lik %p Lp 00, "Tes I.CLENATIONS,ARE REFERrMCED 10 AN ASSUWD DATUM 1 6 ELF J-%-V ME "TTO'NrLEOVA"S Al"SHOW"THUS SUFFMCOUMDEPARTbMTOPHEALTHERVICM I MCNINIUM SEPTIC MAP foot TE I"OLE DATA TANK CAPAO;ISIIES FOR A 1 16 4 BEDROOM ROIJSL IS '.DOD GALLONS I TANK.a*LONG.4'-3'WIDE.V-7-DEEP 4 MHUdUM LE CHIME,5TSTEM FOR A I TO 4 EZEDROOM HOUSE 1$ 500 sq it SrUfwAu ARr^ aq. PERNMT FOR APPROVAL OFCONMuCnON FOR A POOLS.6'DIEM 9' MNGLE FAMLV REw]ENcE ony It DATE HS REF.N(). to-cc-ol If LE�00MG rOOL [:13�Eo sx�m TAstx APPROVED C' T�E LOCATION OF WELLS AND i[55POCES SHOWN HEREON ARE FROM FIELD FOR M&MIUM OF-,4--BE&W� 0 RVAIIONS AkD/OR DATA OBTAINED FROM OTHERS ZXM=THM YLMM FROM DAM OF APPROVAL LOT 1 8 1 THE L', ANT,0—tIl—1 MET w—tAT.,H -n 0 R=60.0 DRAWING LIST LOT 8 T-001 Location Plan + Drawing List - 6 0 TAX NO. 1000-86-01-4.8 T-002 General Notes N 0 CHANGE TO EXISTING � ` BUILDING BULK OR T-003 General Notes v. FOOTPRINT ° .�. T-004 General Notes ` r T-005 ADA Diagrams + Notes F� T-006 ADA Diagrams + Notes ' j c T-007 ADA Diagrams + Notes f �C, ' r- a . EN-001 Energy Code Co pli2nce-:. APPROVED AS NOTED .:173.3 "' A-100 Construction Notes f � DATE B.P,# .+ , �� �� ,� , .. A-101 Construction PI D BY BUILDING DE ARTMENT AT A-200 Ceiling + Electric 7 8 AM TO 4 PM FOR THE . ' � � �'?_ ° i �� FOLLOWING INSPECTIONS: �+ A-201 Ceiling + ElectrioPIOUNDATION-TWOREQUIRED ALL PLUMBING WASTE FOR POURED CONCRETE °'� o , &WATER.LINES NEED P-001 Plumbing Riser a FMING,PLUMBING, G ELECTRICAL&CAULKING TESTINCa,,81EFORE COVERING SiIN 3. INSULATION . FINAL-CONSTRUCTION 8 ELECTRICAL LU,? 8 �' MUST BE COMPLETE FOR C.O. L=39•27 PLUMBER CERTIFICATION l , � _ `�-� � �• � � ON LEAD CONTENT BEFORE ALL CONSTRUCTION SHALL MEET THE 1 REQUIREMENTS OFJTHE CODES OF NEJV CERTIFICATE OF OCCUPANCY YORK STATE. NOT RESPONSIBLE FOR � ,w �2 ! SOLDER USED IN.INATER DESIGN OR CONSTRUCTION ERRORS. SUPPLY S�STOEM CAN OT P. CE Q2I 0 OCCUPANCY -� f ~•e.. Le 1.+.•Y> U E I.M UNLAWFUL ELECTRICAL WITHOUT CE 'Te�iCA r LOCATION PLAN SCALE: INSPECTION REQUIRED i ,Qi n 1 1 OF OCCUPA Y 1/321' = 11-01I 02012BDWARCHPC ALL RIGHTS RESERVED. THESE PLANS ARE AN INSTRUMENT OF SERVICE AND THE PROPERTY OF THE ARCHITECT.INFRINGEMENTS WILL BE PROSECUTED. GENERAL CONTRACTOR IS TO VERIFY ALL CONDITIONS AND DIMENSIONS ON THE PREMISES.DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY WORK. A R C H I T E C T G _ �y Project No.: 012-003 � _ s7�a • Location Plan Brett Residence ETMRI Y■ ^NTENTIC �TON � � i Drawing List 290 Richmond Lane m lwoz ��- ��,�fi 5 Drawn by: pd Peconic, NY 11958 agSX029WOUNS � �, •ARCHITECTURE PC . r _ � Checked by: JBS 1 50 WEST 2BTH STREET y v Date: 5/10/12 SUITE 1 503-B NEW Y❑RK, NY 100131 -�—� T: 646.5❑2.B655 p4 ��' . 2 5/10/12 DOB REVIEW T_00 1 DOBF: 91 7.21 0.42B7 C)NE* 1 4/22/12 PRICING WWW.BARTONO ESIONWORKS.COM - NO. DATE DESCRIPTION Page 1 of 13 SMOKE DETECTOR NOTES 5. DEBRIS, DIRT,AND DUST TO BE KEPT TO A MINIMUM,AND BE CONFINED TO THE IMMEDIATE CONSTRUCTION AREA;AND BE GENERAL NOTES FOR THE INSTALLATION OF SMOKE DETECTORS CLEANED UP AND CLEARED FROM BUILDING PERIODICALLY TO AVOID ANY EXCESSIVE ACCUMULATION. 1. EACH DWELLING UNIT SHALL BE EQUIPPED WITH AN APPROVED TYPE SMOKE DETECTOR DEVICE RECEIVING PRIMARY POWER FROM THE BUILDING WIRING WITH NO SWITCHES IN THE CIRCUIT OTHER THAN THE OVER CURRENT DEVICE PROTECTING THE BRANCH CIRCUIT 2. SMOKE DETECTORS MUST BE EITHER THE IONIZATION-CHAMBER TYPE OR THE PHOTOELECTRIC DETECTOR TYPE. 3. ALL SMOKE DETECTORS MUST BE INSTALLED WITHIN 15'-0" OF THE ENTRANCE OF ANY SLEEPING ROOM,WALL OR CEILING MOUNTED AS INDICATED ON PLAN AS PER N.F.P.A. #74/1980. 4. BATTERY OPERATED DEVICES ARE PERMITTED WHERE THERE IS NO CHANGE IN THE USE OF THE STRUCTURE,AND WHERE THE ALTERATION COST IS LESS THAN 150,000 DOLLARS AND LESS THAN 15,000 DOLLARS PER DWELLING UNIT. TENANT SAFETY NOTES 1. ALL WORK TO BE DONE IN ACCORDANCE WITH THE MUNICIPAL BUILDING CODE,AND REGULATION OF ALL OTHER AGENCIES HAVE JURISDICTION. 2. CONTRACTOR TO PROVIDE ADEQUATE TEMPORARY BRACING AND SHORING WHEREVER ANY STRUCTURAL WORK IS INVOLVED. 3. ALL EXISTING MEANS OF EGRESS FOR TENANTS OF THE BUILDING TO BE MAINTAINED CLEAR AND FREE OF ALL OBSTRUCTIONS,SUCH AS BUILDING MATERIALS,TOOLS, ETC. 4. ALL BUILDING MATERIALS STORED AT CONSTRUCTION AREA AND/OR IN ANY AREA OF THE BUILDING ARE TO BE SECURED IN A LOCKED AREA,ACCESS TO SUCH AREAS TO BE CONTROLLED BY OWNER AND/OR GENERAL CONTRACTOR. Q2ouaow ARCH PC ALL RIGHTS RESERVED. THESEPLANS ARE ANINSTRUM ENT OFSERVICEANDTHE PRO PERTY0FTHE ARCH ITECT.INFRINGEMENTSWILLBEPROSECUTED. GENERAL CONTRACTOR IS TO VERIFY ALL CONDITIONS AND DIMENSIONS ON THE PREMISES.DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY WORK. A R C H I T E C T r Q "• Project No.: 012-003 #�i;i� ��PQ,CON S� �'r.,,`, Notes Brett Residence .T..MU. IMT.IITIOV 290 Richmond Lane � Drawn by: pd Peconic NY 11958 aZl3X0WW0Rae ` �._. .AROMIT[DTURK PC . j, Checked by: JBS 1 50 WEST 26TH STREET Date: 5/10/12 SUITE 1 503 B .� 002 NEW Y❑RK, NY 1 ❑❑❑1 � a2g5 ®'�`.•'' 2 5/10/12. DOB REVIEW DO T: 917.210.8655 F: . .42B7 � 1 4/22/12 PRICING WWW.BART❑N D ESIGNW❑RKS.DpM '�" NO. JDATE IDESCRIPTION Page 2 of 13 GENERAL NOTES 7. NOT USED THE WORK. 23. GENERAL CONTRACTOR AND HIS SUBS ARE RESPONSIBLE FOR ALL LAY-OUTWORK, INCLUDING 8. GENERAL CONTRACTOR TO PRESENT CERTIFICATES OF 16. THE CONTRACTOR SHALL PROVIDE A SPECIFIED LAY-OUT DRAWINGS AS REQUIRED. GENERAL 1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS INSURANCE FOR WORKMAN'S COMPENSATION AND SUPERINTENDENT OR EQUIVALENT ON THE JOB SITE AT CONTRACTOR SHALL COORDINATE RESPECTIVE OF ALL NATIONAL,STATE, MUNICIPAL AND OTHER CODES DISABILITY AND LIABILITY PRIOR TO START OF WORK, ALL TIMES. SUBCONTRACTORS SO AS TO NOT TO CAUSE UNDUE AND AUTHORITIES HAVING JURISDICTION. ALL PLUMBING $1,000,000 MINIMUM. HARDSHIP, DELAYAND INTERFERENCE WITH CONDUCT AND ELECTRICAL WORK TO BE DONE BY LICENSED 17. ALL WORK, LABOR AND MATERIALS SHALL BE OF WORK. WORKMEN. CONTRACTOR SHALL OBTAIN, PAY FOR AND 9. CONTRACTOR SHALL SECURE AND KEEP IN FORCE FOR GUARANTEED BY THE GENERAL CONTRACTOR FOR A SUBMIT TO OWNER ALL REQUIRED PERMITS AND THE DURATION OF THE PROJECT ALL REQUIRED PERIOD OF A MINIMUM OF ONE YEAR, FROM THE DATE 24. GENERAL CONTRACTOR SHALL COORDINATE ALL INSPECTION CERTIFICATES INCLUDING THE CERTIFICATE INSURANCE COVERAGE. OF FINAL COMPLETION. MANUFACTURER'S WARRANTIES BUILDING TRADES TO PROVIDE ROUTING AND LOCATION OF OCCUPANCY. OWNER TO REIMBURSE CONTRACTOR SHALL BE DULY REGISTERED AND FURNISHED TO THE FOR H.V.A.C., PLUMBING, ELECTRICAL, FIRE PROTECTION, FOR DIRECT COSTS OF PERMITS. 10. CONTRACTOR TO PROVIDE A SCHEDULE OF VALUES ( OWNER. STRUCTURAL, ETC.TO PERMIT EXACT LOCATION OF ALL COMPONENT COSTS)TO ARCHITECT BEFORE ARCHITECTURAL ELEMENTS. ANY CONFLICTS OR 2. THESE PLANS ARE SUBJECTTO THE REVIEW AND COMMENCING ANY WORK,OR ORDERING ANY 18. EACH SUBCONTRACTOR SHALL SUBMIT COPY OF DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION APPROVAL OF THE DEPARTMENT OF BUILDINGS OF THE MATERIALS. PROGRESS PAYMENTS SHALL BE MADE HIS INSURANCE COVERAGE(WORKMAN'S OF THE ARCHITECT IN WRITING IMMEDIATELY BEFORE CITY OF NEW YORK. COMMENCEMENT OF ANY BASED UPON PERCENTAGE OF COMPLETION OF THE COMPENSATION, LIABILITY, DISABILITY)TO THE OWNER PROCEEDING WITH THE WORK. CONSTRUCTION IS NOT TO BEGIN UNTIL BUILDING VARIOUS COMPONENT PARTS AS DESCRIBED IN THE PRIOR TO COMMENCING WORK. EACH CONTRACTOR DEPARTMENT APPROVAL HAS BEEN SECURED AND AFOREMENTIONED SCHEDULE. SHALL SUBMIT LIEN RELEASES PRIOR TO REQUESTING 25. DISCREPANCIES, ERRORS,OMISSIONS, ETC., IN ANY REQUIRED CONSTRUCTION PERMIT HAS BEEN OBTAINED. FINAL PAYMENT. PORTION OF THE DRAWINGS WHICH ARE AT VARIANCE 11.WORK PROGRESS SCHEDULE: CONTRACTOR SHALL WITH THE LAW ORDINANCES, RULES OR REGULATIONS, 3. ALL MATERIALS,APPLIANCES, EQUIPMENTAND PROVIDE A WORK PROGRESS SCHEDULE TO BE REVIEWED 19. ALL SUBCONTRACTORS SHALL BE RESPONSIBLE FOR BEARING ON THE CONDUCT OF THE WORK SHALL BE METHODS OF CONSTRUCTION SHALL COMPLY WITH THE WITH THE ARCHITECT AND OWNER BEFORE FILING AND OBTAINING APPROVALS FOR THEIR WORK REPORTED PROMPTLY TO THE ARCHITECT. REQUIREMENTS OF THE MUNICIPAL BUILDING CODE AND COMMENCING ANY WORK OR ORDERING ANY WHICH MAY BE REQUIRED. OTHER GOVERNMENT AGENCIES HAVING JURISDICTION. MATERIALS. 26. THE CONTRACTOR SHALL ERECT AND MAINTAIN AS 20. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR REQUIRED BY EXISTING FIELD CONDITIONS, 4. CONTRACTOR SHALL BE RESPONSIBLE FOR 12. GENERAL CONTRACTOR IS ALERTED TO ORDER LONG MAINTAINING SAFETY ON THE JOB SITE DURING THE THROUGHOUT THE ENTIRE PROGRESS OF THE WORK,ALL SCHEDULING AND OBTAINING ALL INSPECTIONS AND LEAD TIME ITEMS IMMEDIATELY TO ELIMINATE ANY CONSTRUCTION PHASE TO COMPLY WITH THE SAFEGUARDS AND BARRICADES FOR SAFETY PER O.S.H.A. TESTS REQUIRED TO IMPLEMENT THE PLANS AND DELAYS DUE TO UNAVAILABILITY OF MATERIALS. REGULATIONS AND REQUIREMENTS OF OSHA. THIS STANDARDS INCLUDING (BUT NOT LIMITED TO) POSTING SPECIFICATIONS. TESTING AND INSPECTION COSTS BY SHALL INCLUDE, BUT ARE NOT LIMITED TO: PROVIDING WARNING SIGNS, ENFORCING SAFETY REGULATIONS,AND GENERAL CONTRACTOR. 13. CONTRACTOR SHALL LAY OUT HIS WORK, BE FOR ADEQUATE AND PROPER BRACING,SAFETY RAILINGS PROTECTION OF PROPERTY. RESPONSIBLE FOR ITS CORRECTNESS AND SAFETY,AND AND SECURE FOOTINGS FOR ALL TEMPORARY 5, AT LEAST 24 HOURS WRITTEN NOTICE SHALL BE GIVEN SHALL PROVIDE ALL NECESSARY LINES, LEVELS AND SCAFFOLDING,STAIRS, ETC.,AS WELL AS PERMANENT 27. NOT USED TO THE COMMISSIONER PRIOR TO COMMENCEMENT OF DIMENSIONS AS NOTED. ALL MEASUREMENTS AND CONSTRUCTION. ANY WORK,AS PER SEC. C26-118.5 AND 72 HOUR CONDITIONS MUST BE VERIFIED AT BUILDING BY 28. PROTECT ALL WALLS, FLOORS,CEILINGS, ETC.,THAT WRITTEN NOTICE TO BE GIVEN TO THE ARCHITECT TO CONTRACTOR AND SUB-CONTRACTORS BEFORE 21. THE SUBCONTRACTORS SHALL PROVIDE ALL ARE ADJACENT TO THE CORE DRILLING OPERATIONS. ARRANGE FOR INSPECTING ARCHITECT OR ENGINEER ORDERING MATERIALS OR DOING ANY WORK. ANY EQUIPMENT,TOOLS, FENCES,TRANSPORTATION, PERFORM CONTROLLED INSPECTIONS. DISCREPANCIES IN PLANS AND DETAILS MUST BE SAFEGUARDS, ETC.,AS REQUIRED FOR THE PROPER 29. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY REPORTED TO THE ARCHITECT AT ONCE. NO CHANGES OR EXECUTION OF THEIR WORK. THIS WORK FROM THE SITE AND DISPOSE OF IN A LEGAL 6. PRIOR TO CLOSING OF ANY CEILING AND WALL,ALL SUBSTITUTIONS MAY BE MADE UNLESS APPROVED BY MANNER ON A WEEKLY BASIS OR SOONER IF CONDITIONS MECHANICAL SYSTEMS(I.E. H.V.A.C, PLUMBING,AND _ THE ARCHITECT. 22. CONTRACTOR SHALL COORDINATE ALL PHASES OF WARRANT. ELECTRIC)SHALL BE INSPECTED AND WHERE REQUIRED, WORK WITH THE REQUIRED PARTIES. ALL PHASES OF TESTED BY THE LOCAL AUTHORITIES AND PROPERTY 14. MAINTAIN A CURRENT AND COMPLETE SET OF ADJACENT,FACILITIES OPERATIONS SHALL BE MAINTAINED MANAGEMENT OFFICE AND BUILDING ENGINEERS, CONTRACT DOCUMENTS AT THE JOB SITE. DURING CONSTRUCTION. CONTRACTOR SHALL KEEP SITE HAVING JURISDICTION TO INSURE THEIR PROPER FREE OF CONSTRUCTION DEBRIS. INSTALLATION AND FUNCTION. 15. MAINTAIN'ATELEPHONE AND FAX MACHINE WITH WORKING PHONE LINES THROUGHOUT THE PROGRESS OF Q2012 BDW ARCH PC ALL RIGHTS RESERVED. THESE PLANS ARE AN INSTRUMENT OF SERVICE AND THE PROPERTY OF THE ARCHITECT.INFRINGEMENTS WILL BE PROSECUTED. GENERAL CONTRACTOR IS TO VERIFY ALL CONDITIONS AND DIMENSIONS ON THE PREMISES.DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY WORK. A R C H I T E C T �{ ,:= Project No.: 012-003 Brett Residence may` +� Notes wwne � �'`ON Si �;;°:;��a.. eTewwu■ �rlj' � \' 1 � } 290 Richmond Lane `r`} Drawn by: pd Peconic, NY 11958 asBsc>rENwo�Se a I •ARCHITECTURE O JBSChecked by: . 1 50 WEST 28TH STREET mac" ; Date: 5/10/12 SUITE 1 503-B NEW Y❑RK, NY 10001 6504 .,1 2 5/10/12 DOB REVIEW T_003 DO T: 64r.917.210.42B7 F-: 91 �.z1 ❑.4287 � NE�_ 1 4/22/12 PRICING WWW.BARTON D ESIONWORKS.COM �.z.. NO. JDATE DESCRIPTION Page 3 Of 13 GENERAL NOTES INTERPRETATIONS & 7. PRIOR TO SUBMITTING THE BID, RESOLVE ANY CONFLICTS APPARENT CONFLICTS IN REGARD TO LOCATIONS, 30. AT THE COMPLETION OF WORK,THE SITE IS TO BE INTERFERENCES AND JURISDICTION. CLEARED OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY IS TO BE LEFT BROOM CLEAN AND WORK IS TO 1. BRING ANY DISCREPANCIES BETWEEN DIFFERENT 8. THE CONTRACTOR SHALL NOT INTERPRETTHIS BE COMPLETED TO THE TOTAL SATISFACTION OF THE DRAWINGS, BETWEEN THE DRAWINGS AND FIELD y PROJECT TO BE A"MINIMUM CODE DESIGN", OR AN OWNER PRIOR TO RELEASE OF FINAL PAYMENT. CONDITIONS OR BETWEEN THE DRAWINGS AND M "INDUSTRY STANDARD DESIGN",WHERE MATERIALS OR SPECIFICATIONS, OR ANY APPARENT OMISSIONS,TO THE METHODS SHOWN ON THE DRAWINGS,OR SPECIFIED 31. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ATTENTION OF THE ARCHITECT/ENGINEER PRIOR TO HEREIN, INDICATE A PREMIUM MATERIAL OR METHOD. ALL EXISTING WORK ADJACENT TO HIS WORK,OR SUBMISSION OF ANY BID. AFTER AWARD OF CONTRACT, THE CONTRACTOR IS EXPECTED TO PROVIDE SAME,AND DAMAGED AS A RESULT OF HIS WORK. THE INTERPRETATION OF ANY CONFLICT WILL BE MADE PROPOSE ALTERNATE METHODS OR MATERIALS AS A SIDE BY THE ARCHITECT AND SHALL BE ACCEPTED AS FINAL. ITEM. EXCUSES SUCH AS "IT MEETS NEC REQUIREMENTS" 32. ALL EXISTING INSTALLATIONS DISTURBED OR OR"THIS IS THE INDUSTRY STANDARD"WILL NOT BE DAMAGED IN THE COURSE OF PERFORMING ALTERATION 2. THE FAILURE TO QUESTION ANY CONTROVERSIAL ITEM RECOGNIZED AS JUSTIFICATION FOR ACCEPTANCE OF WORK,SHALL BE FULLY AND SATISFACTORILY RESTORED WILL CONSTITUTE ACCEPTANCE BY THE BIDDER,WHO ITEMS NOT CONFORMING TO THE INTENDED DESIGN. TO ITS ORIGINAL CONDITION. SHALL EXECUTE SAME TO THE SATISFACTION OF THE ARCHITECT/ENGINEER AFTER BEING AWARDED THE 9. NO PLANS.SHALL BE SCALED, DIMENSIONS SHALL BE 33. WHERE EXISTING MATERIALS ARE TO BE MATCHED, CONTRACT. USED CARE IS TO BE TAKEN IN BLENDING COLORS AND REPLICATING ADJACENT FORMS AND CONTOURS. 3. SUBMIT DETAILS OF ANY DESIRED DEPARTURES FROM 10. BEFORE SUBMITTING ANY PROPOSAL, IT SHALL BE THE CONTRACT DOCUMENTS AS MAY BE DEEMED THE RESPONSIBILITY OF THE CONTRACTOR TO 34. ALL ELECTRICAL WORK PERFORMED SHALL BE IN NECESSARY,AND THE REASONS THEREFORE,WITHIN 15 FAMILIARIZE HIMSELF WITH ALL CONDITIONS AT THE SITE COMPLIANCE WITH CURRENT NATIONAL ELECTRICAL DAYS AFTER AWARD OF THE CONTRACT, MAKE NO RELATIVE TO EXISTING CONDITIONS, MATERIALS TO BE CODE AND MUNICIPAL ELECTRICAL CODE REQUIREMENTS. . DEPARTURES WITHOUT WRITTEN APPROVAL.. MATCHED,WORKING SPACE AVAILABLE,SAFETY PRECAUTIONS, ETC. REQUIRED FOR THE SAFE AND 35. ALL PLUMBING WORK PERFORMED SHALL BE IN 4. IF MENTION HAS BEEN OMITTED PERTAINING TO EXPEDITIOUS EXECUTION OF THIS CONTRACT. FAILURE TO COMPLIANCE WITH CURRENT MUNICIPAL BUILDING DETAILS, ITEMS OR RELATED ACCESSORIES REQUIRED FOR DO SO WILL NOT BE CAUSE FOR EXTRA COST TO THE CODE AND ALL OTHER APPLICABLE CODES. THE COMPLETION OF ANY ELECTRICAL, PLUMBING, HVAC OWNER OR OWNER'S REPRESENTATIVES. OR OTHER SYSTEM INCLUDE SUCH ITEMS AND 36. ALL MECHANICAL WORK PERFORMED SHALL BE IN ACCESSORIES IN THE CONTRACT WITHOUT ADDITIONAL COMPLIANCE WITH NYC BUILDING CODE AND ALL OTHER CHARGE. APPLICABLE CODES. 5. IT IS NOT THE INTENT OF THE SPECIFICATIONS TO 37. UNLESS OTHERWISE NOTED,ALL EXISTING UTILITIES PROVIDE FOR SUBSTITUTION OF MATERIALS BY SPECIFIC SHALL BE ALTERED, CAPPED,OR RELOCATED AS TO BRAND WHETHER EQUAL OR UNLESS SPECIFICALLY GUARANTEE A COMPLETE INSTALLATION. CALLED OUT. WHERE MATERIALS ARE NOT SPECIFIED CONTRACTORS ARE TO PROVIDE SAMPLES FOR APPROVAL. 6. AFTER THE CONTRACT IS AWARDED,CLAIMS BASED ON INSUFFICIENT DATA OR INCORRECTLY ASSUMED CONDITIONS,OR CLAIMS BASED ON MISUNDERSTANDING THE NATURE OR CHARACTER OF THE WORK OR THE CONDITIONS UNDER WHICH IT MUST BE PERFORMED, WILL NOT BE RECOGNIZED. 02012 BDW ARCH PC ALL UG _ RESERVED. THESE PLANS ARE AN INSTRUMENT OF SERVICE AND THE PROPERTY OF THE ARCHITECT.INFRINGEMENTS WILL BE PROSECUTED. GENERAL CONTRACTOR IS TO VERIFY ALL CONDITIONS AND DIMENSIONS ON THE PREMISES.DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY WORK. A R C H I T E C T A Project No.: 012-003 Brett Residence ��•'c"y ���I° s'41 �► t Notes [T[[NY■ I _INT[NT10 �O. t �. 290 Richmond Lane Peconic NY 11958 _ Drawn by: pd asesc�rrwo�se •AROHITECTURM•o • ";yt tt Checked by: AS 1 50 WEST 2BTH STREET �y `` Date: 5/10/12 SUITE 1503-B �'/ �. 504 NEW Y❑RK, NY 1 ❑❑❑1 2 5/10/12 DOB REVIEW T: 646.5❑2.8655 ®� ��� 1 4/22/12 PRICING DO R F: 91 7.21 0.4287 VV WWW.BARTONDESISNWORKS.COM NO. DATE DESCRIPTION Page 4 of 13 36[914J 36[914] 1 B min 18 18 r 18 15[387] 42[1067] 455 455 455 455 m'r N CONTROL AREA LAV. LAV. .10 ID Z E E O x N N ul ~ C CLEAR FLOOR CLEAR FLOOR `�E m m E 1O E E SPACE SPACE CLEAR FLOOR SPACE 4 Q48[1219] 60[1524] SEAT WALL BACK CONTROL WALL r,'r 48[1219] m r (a) 36-in by 36-in (915-mm by 915mm) Stall (a) Clear Floor Space for Adaptable Bathrooms 27[6861 CONTROL AREA N 36[914] ,n 12 min 12 min 12 [3051 305 305 max 42[1067] y x m m N o m n min oo E TOILET PAPER x " ` Do 0 N N E w.E N m I � ti o0 N ID rn m x m m E m e m E `" E SIDE BACK SIDE E (a) 30-in by 60-in (750-mm by 1525mm) Stall NOTES: (1) The lightly shaded areas are reinforced to receive grab bars NOTE: The lightly shaded areas are reinforced to receive grab bars (2) In Fig. 49(b), shower head and control area may be on back wall (as shown) or on either (b) Reinforced Areas for Installation of Grab Bars side Fig. 47 Water Closets in Adaptable Bathrooms Fig. 49 Location of grab-Bar reinforcements and Controls of Adaptable Showers 02012BDW ARCH PCAURlgfT_SRESERVED THESE PLANS ARE AN INSTRUMENT OF SERVICE AND THE PROPERTY OF THE ARCHITECT.INFRINGEMENTS WILL BE PROSECUTED. GENERAL CONTRACTOR 15 TO VERIFY ALL CONDITIONS AND DIMENSIONS ON THE PREMISES.DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY WORK. - A R C H I T E GT V. ` f ''' Project No.: 012-003 �von* ADA Notes Brett Residence tTt.lY, `114'CMT,o � i 290 Richmond LaneO DBOXGWWOIMZS � aT��r�@�� S � � Drawn by: pd Peconic, NY 11958 ,. : •ARCHITROTURE PC • �" s ' _ Checked bV: JBS 1 5❑ WEST 8TH STREET Date: 5/10/12 SUITE 1503-B 650a NEW Y❑RK, NY 101101 P1� Irl��� 2 5/10/12 DOB REVIEW T 9 1 7 0 6 005 DOB T: .5❑2.8655 �J F: .21 .427 1 4/22/12 PRICING WWW.BARTON DES IGNWO RKS.COM NO. DATE DESCRIPTION Page 5 Of 13 BACK 6 [150] max 24 [610] 24 [610] -min max 50] min F F o r r 48 [1219] o N + N o min CONTROL AREA X SEAT m E w fl 15 [380] ua E N M max M M c op X u c CV C' c W X CLEAR FLOOR DO M E rr) E SEAT M M E M E SPACE CLEAR FLOOR 60 [1527] SPACE min FOOT BACK HEAD (a) With Seat in Tub 60 [1527] min (a) With Seat in Tub 9 [230] max 24 [610] min 6 [150] 13 max 60 [1525] CONTROL AREA tomm SYMBOL KEY X o SHOWER CONTROLS �o E d SHOWER HEAD 15 [380] + DRAIN 15 r3801 w max aW w Max m ..:.. of 0 u c E 1 a0 o N c 00 p JI E to E 75 [1908] FOOT BACK HEAD min (b) With Seat at Head of Tub (b) With Seat at Head of Tub NOTE: The lightly shaded areas are reinforced to receive grab bars Fig. 33 Fig. 48 Location of Grab-Bar Reinforcements and Controls of Adaptable bathtubs Clear Floor Space at Bathtubs 02012 BDW ARCH PC ALL RIGHTS RESERVED. THESE PLANS ARE AN INSTRUMENT OF SERVICE AND THE PROPERTY OF THE ARCHITECT.INFRINGEMENTS WILL BE PROSECUTED. GENERAL CONTRACTOR IS TO VERIFY ALL CONDITIONS AND DIMENSIONS ON THE PREMISES.DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY WORK. A R C H I T E C T Project No.: 012-003 0 ON ADA Notes Brett Residence aTER #SixINT . 1 MT[NTIO � � � * SCHEDULES ,l 290 Richmond Lane O % Drawn by: pd Peconic NY 11958 ag�ssc;�xwo�eae Y � = ter, �' x •ARCHITECTURE PO • � x�-�,�.i r ,, Checked by: JBS 1 50 WEST 8TH STREET Date: 5/10/12 SUITE 1 5❑3-B NEW YORK, NY 1 ❑❑❑1 2 5/10/12 DOB REVIEW T: 646.502.6655 OF NE* T 006 DOBF: 91 7.21 0.4267 1 4/22/12 PRICING WWW.BARTONDESIGNWORKS.COM NO. DATE DESCRIPTION Page 6 of _ 13 17[4321 min 36[914] BACK � 3 CLEAR o - FLOOR G G SPACE 3 0 O U W M rn M •E: 19 [485] max 48[1219] ti rn min LE Fig. 32 1 48[1219] Clear Floor Space at Lavatories (a) 36-in by 36-in(915- mm by 915mm) Stall 27[6861 N W W � O � M Ell' ei L —1 M 60[15241 (a) 30-in by 60-in (750-mm by 1525mm) Stall Fig. 35 Shower Sizes and Clearances Q 2012 BDW ARCH PC ALL RIGHTS RESERVED. THESE PLANS ARE AN INSTRUMENT OF SERVICE AND THE PROPERTY OF THE ARCHITECT.INFRINGEMENTS WILL BE PROSECUTED. GENERAL CONTRACTOR IS TO VERIFY ALL CONDITIONS AND DIMENSIONS ON THE PREMISES.DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY WORK. ARCHITECT Ij;g Project No.: 012-003 f sp„1 , Brett Residence +o % N�!�4, °N Jt� �� DOOR+HARDWARE RTRRMY■ IMT[MTIO x $ ��� �.-• :; ,�s ADA Notes 290 Richmond Lane �� �� r1• y Drawn by: pd Peconic, NY 11958 ase=e>�xwojsae _rv:> , a •ARCHITECTURE PC • � �-.N:=`,jr� >a, Checked by: JBS 1 5❑ WEST 28TH STREET Date: 5/10/12 SUITE 15Y3-B 007 NEW Y❑RK, NY 1 0001 � 2 5/10/12 DOB REVIEW DO T: 917.210.42B7 F: 917.210.4267 1 4/22/12 PRICING WWW.BARTONDESIGNWORKS.COM NO. I DATE IDESCRIPTION Page 7 of 13 Energy Conservation Construction Code Compliance Project Residential Climate Zone: 14A Scope of work: Alterations to existing residence Standard used: ECCCNYS 2010 Item description Proposed Design Value Code Prescriptive Value Code Reference Drawing Building R-38 R-38 ECCCNYS 2010 Envelope Chapter 4 Fenestration Table 402.1.1 A-101 Heating, NOT APPLICABLE - no change to existing base units Ventilating, Air Conditioning Lighting Lighting 10 total fixtures 404.1 Lighting equipment (Mandatory) A minimum of 50 percent of lamps in permanently installed ECCCNYS 2010 A-200; Alterations 50%X 10 = 5 lighting fixtures shall be high efficacy lamps Chapter 4 A-201 6 fixtures proposed > 5 Table 404.1 fixtures req'd Q 2012 BDW ARCH PC ALL RIGHTS RESERVED. THESE PLANS ARE AN INSTRUMENT OF SERVICE AND THE PROPERTY OF THE ARCHITECT.INFRINGEMENTS WILL BE PROSECUTED. GENERAL CONTRACTOR IS TO VERIFY ALL CONDITIONS AND DIMENSIONS ON THE PREMISES.DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY WORK. A R C H I T E C T -�F Project No.: 012-003 Brett Residence �M.,o ��� ON S< $ L r Energy�,,, Ener Code erewwu■ I x Oil I 290 Richmond LaneON Peconic, NY 11958 A ri rat Drawn by: pd asese�r�aro�ese _ � �'� •AR6MITlOTYRR 1.O • Checked by: JBS 1 5❑ WEST 28TH STREET ` Date: 5/10/12 SUITE 1503-6 NEW Y❑RK, NY 10001 2 5/10/12 DOB REVIEW E N-001 D O ^ T: 9 1 7.21 0.4287 �`•{J 8655 F: 9 1 7.21 ❑.42B7 dF N y 1 4/22/12 PRICING WWW.BART❑NDESIGNW❑RKS.C❑M NO. DATE DESCRIPTION Page 8 of 13 CONSTRUCTION NOTES 24. DIMENSIONS MARKED±MEAN ATOLERANCE NOT GREATER NOR 12. G.C.TO SUBMIT TO OWNER,OWNER'S REPRESENTATIVE AND SMALLER THAN 2 INCHES FROM INDICATED.DIMENSION, U.O.N.VERIFY ARCHITECT COPIES OF ALL CONTRACTORS INSURANCE, INCLUDING, BUT FIELD DIMENSIONS EXCEEDING TOLERANCE WITH THE ARCHITECT. SECURE 1. ALL EXISTING WALLS TO REMAIN TO BE SPACKLED AND SANDED TO NOT LIMITED TO VANDALISM AND DESTRUCTION OF PROPERTY. ARCHITECT'S APPROVAL. REMOVE ANY BLEMISHES AS REQUIRED TO RECEIVE NEW FINISHES IF NECESSARY OR REQUIRED BY PLAN. 13. PROVIDE FIRE TREATED WOOD BLOCKING IN WALL AS REQ'D: 25. ALL DIMENSIONS TO THE EXTERIOR WINDOW WALL ARE TO THE WHERE NEW MILL WORK AND WALL MOUNTED OVERHEAD CABINETS INSIDE FACE OF SILL, U.O.N. 2. PATCH AND REPAIR ALL LOCATIONS WHERE OUTLETS,SWITCHES, OCCUR AND FOR MOUNTING BATHROOM FIXTURES,ACCESSORIES AND PHONE LINES AND/OR BOXES HAVE BEEN REMOVED. NO COVER PLATES MISCELLANEOUS FIXTURES AND EQUIPMENT.COORDINATE WITH 26. ALL EXPOSED GYPSUM BOARD EDGES TO HAVE METAL EDGE PERMITTED. FURNITURE AND BATHROOM PLANS. TRIM. 3. PATCH AND REPAIR ALL LOCATIONS WHERE OUTLETS,SWITCHES, 14. G.C. SHALL BE RESPONSIBLE FOR IMMEDIATE CLEANING& 27. ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, PHONE LINES AND/OR BOXES HAVE BEEN REMOVED. NO COVER PLATES REMOVAL OF ALL DEBRIS UNTIL THE PREMISES ARE ACCEPTED IN A CLEAN SQUARE AND TRUE,AND IN PROPER ALIGNMENT. PERMITTED. AND HABITABLE CONDITION BY THE TENANT. 28.. REFER TO MILLWORK SHOP DRAWINGS FOR SPECIFIC DETAILS OF 4. FINAL PLACEMENT OF ALL NEW PARTITIONS TO BE APPROVED BY 15. PARTITIONS SHOWN ALIGNED WITH THE FACE OF EXISTING COORDINATION BETWEEN DRYWALL/MILLWORK CONDITIONS. ARCHITECT PRIOR TO CONSTRUCTION. G.C.TO PROVIDE SNAP LINES FOR CONSTRUCTION OR NEW PARTITIONS SHOULD ALIGN FINISHED FACE TO REVIEW. FINISHED FACE. 29. OBTAIN APPROVAL FROM ARCHITECT PRIOR TO MODIFYING COLUMN FURRING, RELOCATING PIPES AND SIMILAR SYSTEMS AND ITEMS, 5.. GYPSUM BOARD CONSTRUCTION SHALL NOT EXCEED 1/8" IN 8'-0" 16. ALIGNMENT OF DOOR HEADS AND OTHER CRITICAL ELEMENTS ADJUSTING ANY AND.ALL OTHER FIELD CONDITIONS REQUIRED TO FIT VARIATION FROM PLUMB FROM PLUMB OR LEVEL IN ANY EXPOSED LINE SHALL BE MAINTAINED AT A CONSTANT LEVEL AND SHALL NOT FOLLOW PLANS. OR SURFACES, EXCEPT AT JOINTS BETWEEN UNITS. DO NOT EXCEED 1/16" VARIATIONS IN FLOOR PLANE. VARIATION BETWEEN PLANS OF ABUTTING EDGES OR ENDS.SHIM AS 30. ALL EXISTING AND NEW FLOOR SLAB PENETRATIONS FOR PIPING REQUIRED TO COMPLY WITH SPECIFIED TOLERANCES. 17. PARTITION TYPES ABOVE DOORS ARE TO BE THE SAME AS SHALL BE FULLY PACKED AND-SEALED IN ACCORDANCE WITH THE ADJACENT TO DOOR, U.O.N. APPLICABLE BUILDING AND FIRE CODES. 6. DIMENSIONS LOCATING DOORS ARE TO THE INSIDE EDGE OF JAMB. U.O.N.ALL DOORS TO BE 6" FROM WALL, U.O.N. 18. G.C.SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE- 31. FOR ALL NEW PIPE PENETRATIONS AT NEW OR EXISTING BUILDING SITE AND NOTIFY THE ARCHITECT OF ANY DISCREPANCY PRIOR PARTITIONS,SEE PIPE PENETRATION DETAILS. 7. PROVIDE 20 GA.STEEL STUDS AT ALL NEW DOORS HEAD AND JAMB TO COMMENCEMENT OF WORK. LOCATIONS AND ALL PARTITIONS, U.O.N. 32. ALL GLASS SHALL BE CLEAR TEMPERED GLASS, UNLESS OTHERWISE 19. ALL CONCEALED LUMBER&BLOCKING TO BE FIRE TREATED. NOTED.GLAZING TONG MARKS SHALL NOT BE VISIBLE. 8.' ALL DOORS SHALL HAVE V-6" CLR. ON STRIKE/PULL SIDE OF DOOR 33. CLG. HT. PARTITIONS SHALL BE INSTALLED WITH NO JOINTS AND V-0"CLEAR ON PUSH SIDE OF DOOR.VERIFY AND ADVISE ARCHITECT 20. G.C.TO COORDINATE CONST., MILLWORK, FINISH SELECTIONS, OF EXCEPTIONS PRIOR TO CLOSING OUT PARTITIONS. SUBMITTALS, HARDWARE,ALL HVAC, FIRE PROTECTION EQUIPMENT AND VARYING MORE THAN 1/8" OVER V-0"AND NO TIGHT TO FINISHED CLG; DEVICE LOCATIONS WITH ARCHITECT. JOINTS GREATER THAN 3/16", U.O.N. 9. TRIM THE BOTTOMS OF DOORS TO CLEAR THE TOP OF FINISHED FLOOR,AS APPLICABLE, BY 1/4" INCH MAXIMUM, UNLESS OTHERWISE 21. G.C.TO COORDINATE WITH CLIENT'S VENDORS AND NOTED.VERIFY SLAB CONDITIONS.TRIM EACH DOOR TO FIT CONDITION. CONSULTANTS, INCLUDING;THEIR TELECOMMUNICATION,SECURITY,AND WHERE RADICAL VARIATIONS IN FLOOR ELEVATION EXIST, DOORS SHALL FURNITURE VENDORS. BE ORDERED WITH BOTTOM STILE SIZED TO ACCOMMODATE THESE UNDERCUT CONDITIONS. 22. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. PATCH AND REPAIR SURFACES TO 10. PROFESSIONALLY CLEAN, PAINT,AND/OR REFURBISH ANY MATCH ADJACENT OR ADJOINING SURFACES WHERE REQUIRED. MULLIONS AND WINDOWS NOT REPLACED TO LIKE NEW CONDITION. ALL SURFACES SHALL BE ALIGNED AND.SANDED SMOOTH. 11. PROVIDE TO THE OWNER'S REPRESENTATIVE ALL CERTIFICATE OF 23. ALL PARTITIONS ARE DIMENSIONED FROM FINISHED FACE OF APPROVALS TO INCLUDE: PLUMBING,SPRINKLER, ELECTRICAL, FIRE GYPSUM BOARD TO ALL PARTITION UNLESS OTHERWISE NOTED.ALL ALARM,CONTROLLED INSPECTIONS DIMENSIONS MARKED "CLEAR" OR"CLR" SHALL BE MAINTAINED AND SHALL ALLOW FOR THICKNESSES OF ALL WALL FINISHES, U.O.N. 02012BDw ARCH PC Aft RIGHTS RESERVED. THESE PLANS ARE AN INSTRUMENT OF SERVICE AND THE PROPERTY OF THE ARCHITECT.INFRINGEMENTS WILL BE PROSECUTED. GENERAL CONTRACTOR IS TO VERIFY ALL CONDITIONS AND DIMENSIONS ON THE PREMISES.DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY WORK. .�.. A R C H I T E C T ��{a Project No.: 012-003 Brett Residence *�'cx"j"� � SON S,L� CONSTRUCTION NOTES tTRANU■ i _INTCNTIO 290 Richmond Lane. ', �" ^ ° � Drawn by: pd Peconic NY 11958 asB=etirrwogsas -� 5> -. �' ! •AROMITECTURE'PO •. ; °1 ' .Checked by: JBS 1 50 WEST 28TH STREET (n P Date: 5/10/12 SUITE 15❑3-E3 NEW Y❑RK, NY 1 000 1 $ T: 646.5❑2.E3655 a ��. 2 5/10/12 DOB REVIEW A-100 DOB WWW.BF: 91 7.21 ❑.42B7 F NEB 1 4/22/12 PRICING ARTONDESIGNWORKS.COM '` ` • NO. DATE DESCRIPTION Page 9 of 13 ARE A OF WORK 23'-811 j. 61 011 /41 011 .4,-0„ r fN,/O �/%Y THIS AREA /` / / / BUILT-IN / SHELVING BUILT-IN �� SHELVING / BUILT-IN ' I - i A SHELVING i (D STU DY _ w BATH 4 = 1 - —W SD/CO i 0 3'-4" / I / f 31.011 - LEGEND j' , / /'/" i `n EXISTING TO REMAIN /NO Wb is THIS/AREA Ln / NO WO"RK�IS AREA-- / f / CLOJET NEW ro 'j` CL ET o j WALL TYPES FULL HEIGHT GWB PARTITION 41_0 31 411 81-511 A -5 1 1 ONE (1) LAYER /$11 TYPE X GWB NEW GWB CEILING OVER EXISTNG EACH SIDE ON 3-5/8" METAL STUD R-38INSULATION ALL OPENING HABITABLE AREAS CEMENT BACKER BOARD IN WET LOCATIONS 1 CONSTRUCTION PLAN SCALE: SECOND FLOOR 1/411 = 1'-011 pzozz aowascH rc ALL RIGHTS sesesveo. THESE PLANS ARE AN INSTRUMENT OF SERVICE AND THE PROPERTY OF THE ARCHITECT.INFRINGEMENTS WILL BE PROSECUTED. GENERAL CONTRACTOR IS TO VERIFY ALL CONDITIONS AND DIMENSIONS ON THE PREMISES.DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY WORK. A R C H I T E C 1" ='r '" Project No.: 012-003 V CONSTRUCTION PLAN Brett Residences w: ' eTUNO■ INTWNTIO +� ` . SECOND FLOOR 290 Richmond Lane 1t 4a Drawn by: pd Peconic NY 11958 as®=s�xwO�sse •AROHITECTURZ r0 • i ty Checked by: JBS 1 50 WEST 2BTH STREET Date: 5/10/12 SUITE 1 503-13 w, NEW Y❑RK, NY 10013 1 r T: 646.502.E3655 2 5/10/12 DOB REVIEW A101 1 1 �� DOBF: 91 7.21 ❑.4287 "(�� 1 4/22/12 PRICING WWW.9ART0N0ES10NW[3RKS.00M NO. DATE DESCRIPTION Page 10 of 13 CEILING NOTES 8. NOTIFY ARCHITECT OF ANY CONFLICTS OF LIGHT FIXTURE LOCATIONS WITH MAIN RUNNERS, DUCTS,STRUCTURES, HVAC,AND/OR(E)CONDUIT, PRIOR TO 1. NO CUTTING OR CHANNELING OF BUILDING STRUCTURAL FLOOR OR FRAMING FOR LIGHTS.ANY DISCREPANCIES BETWEEN ARCHITECT'S CEILING GRID STRUCTURAL ROOF WILL BE PERMITTED FOR ANY WORK ALTERATION. LOCATION &ACTUAL FIELD CONDITIONS ARE TO BE CLARIFIED WITH THE ARCHITECT PRIOR TO FRAMING. 2. ALL DIMENSIONS ARE TO CENTER OF FIXTURE, U.O.N. 3. UNLESS OTHERWISE NOTED ALL FIXTURES ARE TO BE SUPPLIED INSTALLED 9. ALL SOFFITS AND CEILING HEIGHTS ARE DIMENSIONED FROM TOP OF BY GENERAL CONTRACTOR. FINISHED FLOOR TO BOTTOM OF FINISHED GYPBOARD OR CEILING TILE AND SHALL ALLOW FOR THICKNESS OF ALL FLOOR FINISHES. 4. CONTRACTOR TO PROVIDE UNIT PRICING FOR ALL WORK 10. ALL SWITCHES AND DIMMERS SHALL BE LOCATED 48"ABOVE FINISHED 5. INSTALL LIGHT FIXTURES WITH PROTECTIVE FILM OR SIMILAR COVER OVER FLOOR TO CENTER OF SWITCH U.O.N. MULTIPLE SWITCHES AT ONE LOCATION LOUVER, LENS, BAFFLE,AND THE LIKE,TO AVOID FIXTURE SOILING OR DAMAGE; SHALL BE GANGED TOGETHER AND FINISHED WITH ONE COVER PLATE U.O.N FIXTURES SHALL BE MAINTAINED CLEAN AND AS NEW; LAMPS SHALL BE NEW AT PROJECT COMPLETION. 11. COORDINATE THE WORK OF ALL TRADES INVOLVED IN THE CEILING WORK 6. FURNISH AND INSTALL UNDERWRITERS LABORATORIES INC. (UL) LABELED TO INSURE CLEARANCES FOR FIXTURES, DUCTS, PIPING, CEILING SUSPENSION DEVICES THROUGHOUT. SYSTEM, ETC., NECESSARY TO MAINTAIN THE FINISHED CEILING HEIGHTS INDICATED ON ARCHITECT'S DRAWINGS. 7. VERIFY FIELD CONDITIONS AND LOCATIONS OF ALL PLUMBING, MECHANICAL DUCTS,STRUCTURAL ELEMENTS AND ANY AND ALL OTHER APPLICABLE ITEMS; INSTALL APPLICABLE NEW PLUMBING, MECHANICAL FANS.- DUCTS,CONDUITS,AND OTHER RELATED AND APPURTENANT ITEMS SO AS TO NOT CONFLICT WITH LUMINARES AND ANY AND ALL FIELD CONDITIONS. LIGHT FIXTURE SCHEDULE SYMBOL QTY DESCRIPTION LAMPING MANUFACTURER PRODUCT NO. FINISH REMARKS A 3 RECESSED * LED MR16 BASE Al 1 RECESSED * LED MR16 BASE WET LOCATION B 2 SURFACE MOUNTED * 17W CFL C 2 PENDANT 100 W INCANDESCENT D 1 WALL SCONCE 100 W INCANDESCENT F 1 CEILING FAN 100 W HALOGEN TOTAL 10 HIGH EFFICACY 6 ECCCNYS2010 404.1 Lighting equipment (Mandatory) A minimum of 50 percent of lamps in permanently installed lighting fixtures shall be high efficacy lamps 02012 BDW ARCH PC;;�gIGFFf5RE5ERIIE,D,,,,. THESE PLANS ARE AN INSTRUMENT OF SERVICE AND THE PROPERTY OF THE ARCHITECT.INFRINGEMENTS WILL BE PROSECUTED. GENERAL CONTRACTOR IS TO VERIFY ALL CONDITIONS AND DIMENSIONS ON THE PREMISES.DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY WORK. ' 3 A.R C H I T E C T R,. Project No.: 012-003 tone �� �'�O�.rS/���R a r Brett Residence °� k CEILING NOTES [T[!MY■ I _IMT[MTI! � �+yy�� �Ii, 290 Richmond Lane �$ q Drawn by pd Peconic, NY 11958 OZON 08 � •ARCHITECTURE ro • t ; Checked by: AS 1 50 WEST 28TH STREET .� Date: 5/10/12 SUITE 1 503-13 NEW Y❑RK, NY 1 ❑❑❑1 ©'F MIENS 2 5/10/12 DOB REVIEW 55 A 200 D O T: 9 1 7.21 0.4287 F: 91 7.21 ❑.4287 - 1 4/22/12 PRICING WWW.8ART❑NDE8IGNWORKS.C❑M NO.. DATE DESCRIPTION Page 11 of 13 POWER SYMBOLS LEGEND DUPLEX RECEPTACLE EX EXISTING N NEW DM 'DEMO QUAD RECEPTACLE GFI GROUND FAULT INTERRUPT RECEPTACLE CAN ARC FAULT AFCI INTERRUPT RECEPTACLE TEL® TELEPHONE OUTLET F CATV® CABLE TV OUTLET —— — — — — - -- — — — — — — — — —— —— te — -- - — CATV® CATEGORY 5 CABLE TERMINATION HOMERUN TO DESTINATION LOCATION INTERCOM INT® GC TO COORDINATE WITH BUILDING VENDOR AFCI3 AFCI �B C B \� 1 REFLECTED CEILING SCALE: SECOND FLOOR 1/4" = 1'-0" ®zoiz eowaacH vc ALL RIGHTS RESERVED. THESE PLANS ARE AN INSTRUMENT OF SERVICE AND THE PROPERTY OF THE ARCHITECT.INFRINGEMENTS WILL BE PROSECUTED. GENERAL CONTRACTOR IS TO VERIFY ALL CONDITIONS AND DIMENSIONS ON THE PREMISES.DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY WORK. A R C H I T E C T' ��R A Project NO.: 012-003 �� CEILING+POWER PLAN Brett Residence ��� ��� ��°N3��`��. s�Rwu d IRTegTIR ` 4' 1 _ . r� SECOND FLOOR 290 Richmond Lane e: �f Peconic, NY 11958 „�, �• Drawn by: pd •ARUNITEUTURt pp . - t _ Checked by: JBS 1 50 WEST 2STH STREET Date: 5/10/12 SUITE 1 502-8 ' NEW Y❑RK, NY 1 ❑❑❑1 A 201 2 5/10/12 DOB REVIEW DOB T: 9 1 7.2 1 0.4287 Rt EV{ F: 9 1 7.2 1 ❑.4287 r� 1 4/22/12 PRICING WWW.SARTONE)ESIGNW❑RKS.COM - NO. JDATE DESCRIPTION Page 12 Of 13 r , NEW VENT STACK EXISTING VENT STACK ROOF I I r_ - >- ---� Jxx _ _ ---� _-T - - - - -I _ I �, �� „ I I I I I 2 111/2 i 11/2 i 11/2 y 111/2 11 1/2" I I I I �-1 1/2 1 1/2" I�-11/2" 11/2" r I. 2 -i I I I WASHER I r 2 SHOWER I BATH TUB I I I I I I I SHOWER I I I BATH TUB 2nd 4"✓ 11/2" 11/2° 1 1/z° �1/2" 11/2" 411 4" 2 11/ 11/2" 4 4 14„ NEW EXIST. NO CHANGES EXI T.NO CHAN ES EXIST. NO CHANGES BATHROOM 4 BATHROOM 2 LAUNDRY BATHROOM J BATHROOM 3 NEW WASTE STACK r I EXISTINd WASTE STACK I I I I1/2" BRAIDED NOTE: 11/2" 11/2"-� �I 11/2' CABL HOSE �{ I INSTALL NEW,ACCESSIBLE BALL SHUT-OFF VALVES 2" I KITCHEN I DISHWASHER AND SWING CHECK VALVES IN HOT AND COLD I I I SINK WATER BRANCH PIPING. SHOWER I I 11/2" r St I 2", I I EXIST. NO CHANGES EXIST. NO CHANGES BATHROOM 1 KITCHEN I 4_, Cellar PLUMBING RISER SCALE: 1 DIAGRAM NTS pzazz aownrtcH ac ALL RIGHTS aesenveo. THESE PLANS ARE AN INSTRUMENT OF SERVICE AND THE PROPERTY OF THE ARCHITECT.INFRINGEMENTS WILL BE PROSECUTED. GENERAL CONTRACTOR IS TO VERIFY ALL CONDITIONS AND DIMENSIONS ON THE PREMISES.DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY WORK. A R C H I T E C T ±F: �= t � 4` Project No.: 012-003 Brett Residence ,�' ``� �` �� s�tU� PLUMBING RISER etewwu• wrewro N DIAGRAM 290 Richmond Lane vi $ m�� Peconic NY 11958 , Drawn by: pd ase=e,�rsrwogess •ARCHIreoruRE ra • �+ � r Checked by: JBS 1 5❑ WEST 2B•TH STREET Date: 5/10/12 SUITE 1 5❑3-B t1 NEWY❑RK, NY 10001 �yy �•d 2 5/10/12 DOB REVIEW 1 T: 646.5❑2.6655 L�� . P OO 1 1•O 1 DOBF: 91 7.21 0.4267 1 4/22/12 PRICING WWW.BARTONDESIGNWORKS.COM NO. I DATE IDESCRIPTION Page 13 Of 13