Loading...
HomeMy WebLinkAbout37067-Z . g�FFOt,f Town of Southold Annex 11/29/2012 P.O.Box 1179 IN N i 54375 Main Road o • Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 37067 Date: 11/29/2012 THIS CERTIFIES that the building WOOD STOVE Location of Property: 155 Seawood Dr, Southold, SCTM#: 473889 Sec/Block/Lot: 88.-2-3 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 3/5/2012 pursuant to which Building Permit No. 37067 dated 3/14/2012 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: wood,burning stove as applied for. The certificate is issued to Greco Jr, Lawrence&Greco,Maureen (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED )AAorjied Si ature �SUFFn� TOWN OF SOUTHOLD BUILDING DEPARTMENT co TOWN CLERKS OFFICE o . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 37067 Date: 3/14/2012 Permission is hereby granted to: Greco Jr, Lawrence & Greco, Maureen 7 Valley Rd Clifton, NJ 07013 To: install a wood burning stove as applied for At premises located at: 155 Seawood Dr, Southold SCTM # 473889 Sec/Block/Lot# 88.-2-3 Pursuant to application dated 3/5/2012 and approved by the Building Inspector. To expire on 9/13/2013. Fees: SINGLE FAMILY DWELLING -ADDITION OR ALTERATION $200.00 CO -ALTERATION TO DWELLING $50.00 Total: $250.00 Building Inspector Form No.6. TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and.submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form)_ 3. Approval ofeleetrical installation from Board of Fire Underwriters. 4. Sworn staterrfent from plumber certifying that the solder used in system contains less than 2/10 of I% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations,a certificaie of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. $. For existing buildings (prior to April 9,1957) non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. Lf a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees .1. Certificate of Occupancy-New dwelling$50.00, Additions to dwelling$50.00, Alterations to dwelling$50.00, Swimming pool $50.00, Accessory building$50.00, Additions to accessory building$50.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. . Updated Certificate of Occupancy- $50.00 .5. Temporary Certificate of Occupancy- Residential $15:00, Commercial $15.00 Date_ New Construction: Old or.Pre-existing Building: check one Location of Property: / � \ ,�awvo �p Socl%4o,1 House No. Street Hamlet Owner or Owners of Property: 10(vreor« JAI Suffolk County Tax Map No 1000, Section $ Block Lot Subdivision Filed Map. Lot: Permit No. ��(� Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: ' Temporary Certificate Final Certificate: (check one) Fee Submitted: $ �� f2eG 9-1 ss� Applicant Signature OF SO(/r�olo 70 7r moo! • �o TOWN OF SOUTHOLD BUILDING:DEPT. . 765-1802 INSPECTION . . ' . [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND. [ ] INSULATION. [ ] FRAMING/STRAPPING XFINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION " [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL(FINAL) REMARKS: Lill. DATE INSPECTOR pF SO(/r�,o - y cOUHi'I,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG.. [ ] FOUNDATION 2ND [ ] IN ATION [ ] FRAMING/STRAPPING [ INAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: X) DATE Y INSPECTOR. NEPO , DATE CbI►'Il1?ENTS. FOUNDATION(1ST) � V111�y/ FOUNDAZ7ON(2ND) �J • PI,UIIMING I SUL•ATION PEIt N.'Y. STATE ENERGY CORE ;tA fee . a d-- R}NAL ADD , ONA .COBM.WNTS . tv TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT J Do you have or need the following,before applying? TOWN HALL v Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. l 6 7 Check Septic Form N.Y.S.D.E.C. Trustees C.O. Application Flood Permit Examined 3 1 20 Single&Separate ((� Storm-Water Assessment Form C� I lJ on'tactjai A G ` Approved V / 1,20 /� MAR - 5 2012 l to: Disapproved a/c �/��'�� BLDG.DEPT. Phone: 73 a 5 701 Expiration 20 TOWN OF SOUTHOLD Building nspector APPLICATION FOR BUILDING PERMIT Date , 20 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations,for the construction of buildings,.additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name, if a corporation) al a s i lchlll DATE ZB.P. State whether applicant is owner, lessee, agent, architect, engineer, general contracto , e ctrician,pi or uilder FEE: BY NOTIFY BUILDING DEPARTMENT A- ,o rUF< Me � CO- LLOWING INSPECTIONS Name of owner of premises t awreetc—e - Iw,/'v✓PPr1 -e_ V E01 INDATION-TI- O ' I-11RED (As on the tax roll or latest dOldPOURED CGNCRLTE If applicant is a corporation, signature of duly authorized officer 2. ROUGH-FRAMING,PLUMBING, STRAPPING,ELECTRICAL&CAULKING 3. INSULATION , (Name and title of corporat W [J 4. FINAL-CONSTRUCTION&ELECTRICAL Builders License No. 0 p; @ o I INJI 1 , MUST BE COMPLETE FOR C.O. Plumbers License No. _ �,� 'L ��- ALL CONSTRUCTION SHALL MEET THE i I �" '�� REQUIREMENTS OF THE CODES OF NF'N Electricians License No. I> ¢ '`��1'I�Ilr'%01® YORK STATE. NOT RESPONSIBLE FOR Other Trade's License No. ' s a°{c DESIGN OR CONSTRUCTION ERRORS 1. Location of land on which prK&4 d work will be done: /s 5L �mod, `°e�� r��z Id House Number Street Hamlet County Tax Map No. 1000 Section Block- Lot Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and i tended use and occupancy of proposed construction: a. Existing use and occupancy . F a,M� k owf b. Intended use and occupancy �`� ' 3. Nature of work(check which applicable): New Building Addition Alteration coil Repair Removal Demolition Other Work �,' , (Description) 4. Estimated Cost ®� Fee .(To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO 14. Names of Owner of premises Address Phone No. Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on pro{�perty is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? ' YES-NO IF YES;PROUIDEA-GQ.PY:ua �'' '" STATE'OF NEW'YO.kk)-3 $S COUNTY OF T, ;. . being duly sworn, deposes and says that(s)he is the applicant (Name of individual signng'coiitract),above named, CONNIE D. BUNCH Notary Public,State of New York (S)He is the VlN'TA'NJ. ,;"'+ .c No.01 BU618505() i Cozit'a i6r, Agent, Corporate Officer, etc.) Qualified in.51.11folk County -Commission Expires April 14, of said owner or,:owners,,and is--,,du-jy%,kutpr*t7p d to perform or have performed the said work and to make and file this application; that all statements contained"iii.tliis"application are true to the best of his knowledge and belief; and that the work will be performed in the mannerrs&t'fortli=',in'the"appl'ieatioil filed therewith. Sworn to before me thi 41 day of 20 J Notary Public Signature of Applicant 3`7 C(c- PACI FIC LE R GY R SAFETY NOTICE If this stove is not properly _ installed a house fire may = \\ result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and. installation inspection ' requirements in your area. I,r TESTED and LISTED to CAN/ULC S627-M93 AND UL 1482-98 Meets the U.S. Environmental Protection Agency's July 1990 Particulate Emission INSTALLATION Standards AND OPERATING Warnock Hersey INSTRUCTIONS Models C ®® us Pacific VISTA VISTA CLASSIC STUDY CAREFULLY BEFORE PROCEEDING SERIES - C PLEASE SAVE THESE INSTRUCTIONS 111206-16 VISTA and CLASSIC-C 5055.3 Contents SAFETY AND MAINTENANCE.......... ..............3................................................:.............................. ASSEMBLY......................................................................................................................................4 MOBILE HOME INSTALLATION.....................................................................................................6 RESIDENTIAL INSTALLATION.......................................................................................................7 FLOOR PROTECTOR.....................................................................................................................7 COMBUSTIONAIR .........................................................................................................................8 WOOD SELECTION........................................................................................................................8 OPERATING....................................................................................................................................8 PROPERDRAFT.............................................................................................................................9 ASHREMOVAL...............................................................................................................................9 BAFFLEREMOVAL.........................................................................................................................9 OPTIONALBLOWER....................................................................................................................10 TROUBLESHOOTING...................................................................................................................10 CREOSOTE FORMATION AND NEED FOR REMOVAL...............................................................11 REPLACEMENT PARTS-PACIFIC VISTA...................................................................................12 REPLACEMENT PARTS-VISTA CLASSIC.................................................................................13 FIREBRICK INSTALLATION INSTRUCTIONS.............................................................................14 SAFETY LABEL-Pacific VISTA and VISTA CLASSIC...............................................................15 Pacific Vista - Pedestal Model Pacific Vista - Leg Model 24° 20 1/16" - __24 _._..__.....__....-- -201/16" 5 7/8 I 15 7/8' -----61/4" I 511/16"------ 6114" 511/16"-:------ 27 3/4 I I 27 3/4" i Vista Classic 24 7/8" I - 19 5/8"- -15 7/8" --..._ i -- 61/4" 511/16" I --- - ... ............. ............................ ...... i i 27 3/4 71177 i 2 VISTA and CLASSIC-C 111206-16 • PLEASE SAVE THESE INSTRUCTIONS • NOTE: WE STRONGLY RECOMMEND THAT SMOKE DETECTORS BE INSTALLED. If smoke detectors have been previously installed,you may notice that they are operating more frequently. This may be due to curing of stove paint or fumes caused by accidentally leaving the fire door open. Do not disconnect the detectors. If necessary, relocate them to reduce their sensitivity. • SAFETY NOTICE: IF THIS STOVE IS NOT PROPERLY INSTALLED,A HOUSE FIRE MAY RE- SULT. FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA. SAFETY AND MAINTENANCE 1. Burn wood only, dry and well seasoned. The denser or heavier the wood when dry,the greater its heat value.Thisis 5. DOOR GLASS -Do not slam loading door or otherwise why hardwoods are generally preferred.Greenorwetwood impact glass. When closing door,make sure that no logs will cause a rapid buildup of creosote. If you feel it is protrude to impact the glass. If the glass gets cracked necessary to burn wet or unseasoned wood,do soonlywith or broken, it must be replaced before using the stove. the air inlet set open enough to maintain a good strong Replacement glass can be obtained from your dealer. fire and fairly high chimney temperatures. Do not attempt Only ceramic glass,which measures 8-5/8"x 14-1/8"x5mm to burn overnight using green wood orwetwood.Wetwood must be used.Do not substitute with any other type. can cause up to 50% drop in heater output, as well as To remove broken glass,undo the four retaining screws and contributing significantly to creosote buildup. removetheframe,noting position for re-assembly. Remove all particles of glass. Be careful, as they are very WARNING: Never use chemicals or any other volatile sharp. Install new glass complete with gasket. Replace liquid to start a fire. Do not burn garbage, or flam- frame and screws. mable fluids such as gasoline, naphtha, or engine oil. We strongly recommend that smoke detectors be CAUTION: installed. -do not overtighten,tighten screws very carefully -do not clean glass when hot 2. Remove ashes frequently. Embers can roll out the door -do not use abrasive cleaners on glass and create a fire hazard.Maintain a 1"minimum ash base. 6. Do not store wood within heater installation clearances, 3. If glass becomes darkened through slow burning or poor or within the space required for fuel loading and ash re- wood, it can readily be cleaned with a fireplace glass moval. Keep the area around the heater clean and free of cleaner when stove is cold. Never scrape with an object loose combustibles,furniture, newspapers, etc. that might scratch the glass.Thetype and amountofdeposit ontheglass isa good indication of the flue pipe and chimney 7. If gold door requires cleaning, use mild soap and water buildup. A light brown dusty deposit that is easily wiped only. Use of abrasive cleaners will void warranty. off usually indicates good combustion and dry, well seasoned.wood and therefore relatively clean pipes and 8. Establish a routine for the fuel, woodburning and firing chimney. On the other hand,a black greasy deposit that is technique.Check daily for creosote buildup until experience difficult to remove is a result of wet and green wood and shows how often you need,to be cleaning to be safe. too slow a burning rate. This heavy deposit is building up at least as quickly in the chimney. 9. Be aware thatthe hotterthefire,the less creosote is deposited. Weeklycleaning maybe necessaryinmildweather,eventhough WARNING: ONLY USE MATERIALS SUPPLIED BY monthly cleaning is usually enough in the coldest months MANUFACTURER WHEN DOING MAINTENANCE OR when burning rates are higher. REPLACEMENTS. 10.Instruct all members of your family on the safe operation 4. DOORGASKETS-Thegasket used byPacificEnergyrequires ofthe heater.Ensure they have enough knowledge oftheentire only light pressure to seal. This will prolong seal life. system if they are expected to operate it.Stress the section It is important that the door seal be maintained in good on chimney fires and the importance of following the steps condition. Periodically inspect seals and replace if outlined"In Case of Chimney Fire". necessary.Obtain a replacement gasket from your nearest Pacific Energy dealer. 111206-16 VISTA and CLASSIC-C 3 FIG. #1a Minimum Clearances to Combustibles Single Wall Connector - Residential 20 3/4" 15" 11 10 22 5/8" 14" 26"— 10"1 Double Wall Connector - Residential 712" 16 3/4" 11" 15 5/8' 3" 12" 12" 24" 3'. Alcove height-7'min. Alcove depth-3'max. Double Wall Connector - Mobile Home } 8„ 17 3/4" 12" I 20 5/8" 12 24"— 8„ ASSEMBLY LEG KIT: CRATE REMOVAL: 1) With the unit on its back and removable cover of the ash 1) Carefully remove wood top and supports. drawer enclosure facing up, align mounting holes with 2) Remove plastic cover. studs on stove bottom. 3) Using a 7/16"wrench,remove lag bolts that secure stove 2) Position the legs on the stove. body to bottom pallet. 3) Place the 1/2"washers over the studs and secure in place 4) Place stove body carefully on its back. with 1/2"nuts previously removed. 4) Carefully place the unit in an upright position. 5) Using a 3/4"wrench,remove 1/2"nuts and save them for later use. OPTIONAL ASH CLEANOUT SYSTEM: 6) Remove pallet retaining brackets from stove bottom. PEDESTAL KIT: 1) With stove body laying on its back, remove the 1/4"x 1" Tek screw located at the top left of the stove bottom. 1) With the unit on its back and removable cover facing up, 2) Remove the ash system hole cover and gasket located align the pedestal mounting holes with the studs on stove under the stove.discard the cover plate and gasket. bottom. 3) Place new gasket provided over existing studs. 2) Secure in place with 1/2"nuts previously removed. 4) Install ash dump system over gasket and secure with two 3) Carefully place the unit in an upright position. 1/2"nuts previously removed. 5) Install the 1/4" Tek screw back to the original hole and secure. 4 VISTA and CLASSIC-C 1 1 1 206-1 6 FIG. #2 Spark arrestor The chimney may incorpo- rain cap rate an offset.- To do this safely, all sections of listed connector, offset elbows and chimney section must be screwed together by at least three sheet metal T Chimney screwsperjoint.The chim ney must be suitably supported Storm collar by the chimney manufac- 36" (914 mm turer's listed offset sup- Minimum port. Roof flashing Radiation shield 7'(2.1 m.) Chimney support Minimum Ceiling Height _ Chimney connector 58" (1473 mm) " Minimum Attachment to floor for mobile homes 48" (1219 mm) Non-combustible floor Minimum protector Hooded vent ' 4"diameter air inlet with rodent screen oL ' If crawl space is well ven- tilated it is not necessary to extend air inlet to outside 111206-16 VISTA and CLASSIC-C 5 MOBILE HOME INSTALLATION CHIMNEY AND CHIMNEY CONNECTOR Warning: Under no circumstances is this heater to be This heater must be installed with double wall connector and installed in a makeshift or"temporary"manner.It may be compatible chimney system listed below. fired only after the following conditions have been met. NOTE:Longer chi mney lengths and different pitch flashings may be used.All other parts listed must be installed (see Figure • DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE #2, Page 6). Install all components to the connector or SERVING ANOTHER APPLIANCE. chimney manufacturer's installation requirements. Consult your chimney supplier for installation advice. • DO NOT INSTALL IN SLEEPING ROOM PROCEDURE • Outside airsupply must be used for Mobile Home instal- lations(see Fig.#2,Page 6) Note:See"Combustion Air"section on page 9. 1. Position stove and floor protection with the clearances as The services of a competent or certified installer, stated on the label or as in Figure#1a and 1b, page 4& certified by the Wood Energy Technical Training pro- 5. gram(WETT)-in Canada,Hearth Education Foundation 2. Mark the position for the hole in the ceiling and roof by (HEARTH)-in U.S.A.,are strongly recommended. using a string and plumb-bob. 3. Check that the intended location will not interfere with CAUTION: THE STRUCTURAL INTEGRITY OF THE MO- floor joists, ceiling joists or rafters before proceeding BILE HOME FLOOR , WALL AND CEILING/ROOF MUST further. BE MAINTAINED. 4. Cut a hole in the ceiling and roofto suitthe chimneysystem and frame in the sides.The chimney support is mounted to the CLEARANCES framing. 5. Assemble chi mney sections(twist locks)sothe finished length This heater must be installed with listed double wall connec- is resting on support and protruding through the roof. for and compatible chimney system. Avoid having joints between ceiling and roof. Install Pacific Vista and Vista Classic: Clearances to combustible radiation shield. Assemble flashing and storm collar and surfaces and materials are shown in Figure#1 a, page 4. be sure to maintain the vapour barrier at this point. (Seal securely) Attach rain cap and check flashing for leaks. Clearances may be reduced with various heatinsulating materi- 6. Install connector as per manufacturer's instructions. als.Consult local fire codes and authorities for approval. 7. Attach stove to flooring using two 1/4" x 2" or longer lag screws. LISTED CHIMNEY AND CHIMNEY CONNECTOR A.Double-wall connector systems: 1.Security Model DP or DC 5.Metal Fab Model DW 2.Oliver MacLeod Model PV 6.Ameri-Tec Model DBSP 3.Ryder Model"E"Vent 7.Industrial Chimney Model Excel Ultra-Black 4.Selkirk Metalbestos Model DS 8.Simpson Dura-Vent Model DVL B.Compatible chimney systems: In CANADA: Security Pro-Jet Selkirk Industrial Chimney Energy Vent -All parts 6" S2100 H.T.3000 Sentinal CIF Excel 2100 Commander 5000 Ceiling support XSF FCS CF-CSP RDS CH6LCS Rafter radiation shield XRST RRS CF-CSP CRS CH6LCS 3'Chimney length XL3 SL3 CF-36SL CL48 CH636 - 2'Chimney length XL2 SL2 CF-24 CL24 CH624 Roof flashing XFA RF17 CF-FRA VF CH6TCF Storm collar XSC SC CF-SC SC CH6SC Spark arrester rain cap XCPE RCSA CF-SA,CT RC,RCS CH6RC,SS In U.S.A.: Security Security Pro-Jet ProJet Metalbestos MetalFab Ameritech Simpaon Dura-Vent -All parts 6" ASHT S2100 HT3103 H.T.3000 SSII 2100 TEC HS Dura/Plus Dura Tech Ceiling support SF XSF FCS FCS TSFA TGCSP 6PL-CS SDPSB SDTSB Rafter radiation shield RSMH XRST RRS RRS TJSMH TGRS 3'Chimney length L3 X0 SL3 SL3 T-36 TG3 HS 36 SDP-P SDT-P 2'Chimney length L2 XL2 SL2 SL2 T-24 TG2 HS 24 SDP-P SDT-P Roof flashing FA XFA RF RF17 T-SFA TGF 8RFFU SDP-F SDT-F Storm collar SC XSC SC SC T-SC TGSC PL-ASCG SDP-SC SDTSC Spark arrestor rain cap CPE XCPE RCSA RCSA T-CT TGC 6PL-MPC SDP-C SDT-C 6 VISTA and CLASSIC-C 1 1 1 206-1 6 RESIDENTIAL INSTALLATION 4. To start installing single wall connector (smoke pipe), slip crimped edge of the pipe inside the stove collar. Use Warning: Under no circumstances is this heater to be holes provided in collar to secure pipe with two screws. installed in a makeshift or"temporary"manner.It may be 5. Install the remaining lengths of pipe one on top of the fired only after the following conditions have been met. othertothefinished heightofthechimneyconnectorand secure • DO NOT ATTEMPT TO CONNECT THIS HEATER TO to each other.When approaching the ceiling,slip the ceiling ANY AIR DISTRIBUTION DUCT. trim plate and joist shield over the chimney so that after • The services of a competent or certified installer,certi- the chimney is extended through the ceiling,the trim plate can fied by the Wood Energy Technical Training program be secured to the ceiling. (WETT) - in Canada, Hearth Education Foundation (HEARTH)-in U.S.A.,are strongly recommended. • Outside combustion air may be required in your area, FLOOR PROTECTOR consult local building codes. The stove may be installed on a combustible floor provided CLEARANCES non-combustible protection is used. 1. This heater may installed using a single-wall connector This protection must extend as follows: (smoke pipe)or a listed double-wall connector. In Canada: 18"(457 mm)on the firing side and 8"(203 mm) Pacific Vista and Vista Classic: Clearances to combustible to the other sides. See Figure#3a below. surfaces and materials are shown in Figure#1 a, page 4. In USA: 16" (406 mm)to the front and 8" (203 mm)to the fuel loading door opening. See Figure#3b below. This pro- Clearances may be reduced with various heat insulating materi- tection is also required underthe chimney connector and 2"(51 als.Consult local fire codes and authorities for approval. mm)beyond each side. CHIMNEY Only Canada n Connect to a listed Factory-Built Chimney or a chimney FIG.#3a Cana y suitable for use with solid .fuel that is lined and in good Minimum Width-40" condition and meets building code. Chimneyflue exit isto be 3' Minimum Overall Depth-43 1/4" (1 m.)above roof and 2'(.6 m.)above the highest projection within 10' (3 m.). The installation must meet all local 8"[203mm] codes.Do not connect this unit to a chimney flue serving another appliance.Minimum chimney height is 15'(4.6 m.)measured from base of appliance. 1_�G DOUBLE-WALL CONNECTOR 02 N E 0 0 * Use a listed double-wall connector for use with solid fuel. co o * Install all components to the chimney connector manu- facturer's installation requirements. .F a o y SINGLE-WALL CONNECTOR(Smoke Pipe) 18"[457mm] a o Z FL Smoke pipe must be: * secured at every joint and collar with 3 sheet metal screws * installed with the crimped or male ends pointing down.This FIG. #3b will carry any liquid creosote or condensation back into U.S.A. Only the stove Minimum Width-32" * The chimney connector should not pass through attic or roof Minimum Overall Depth-33 1/4" space,closet or similar concealed space,or floor,ceiling, wall, or partition of combustible material. Floor protection is required under horizontal chimney connector and 2"beyond each side. C PROCEDURE w 1. If a listed chimney and double-wall connector is to be 3 I o connected to the stove, see MOBILE HOME INSTALLA- TION section.(Outside combustion air may not be required, E \ o consult local building codes.) o y c a` 2. If it is desirable to use single wall connector in conjunc- 16"[406mm] y °o tion with insulated chimney,see step 4. co Z a 3. If a roof or ceiling support is used in the installation, you will find the chimney manufacturer's complete instruc- tions packed with the roof support. 1 1 1 206-1 6 VISTA and CLASSIC-C 7 within one minute. It is damp if it turns black and lights within COMBUSTION AIR three minutes.If itsizzles,hissesand blackenswithout igniting in five minutes it is wet and should not be burnt. Intake or combustion air can be supplied to the stove in one MORE WOOD,MORE HEAT of two ways. Seasoned wood has approximately 7500 BTU's per pound. If 1.Outside air supply-(Necessary for mobile home installa- ptional for residential installation) To draw you put 10 pounds of wood in yourstove foran eight hour burn tion, o outside optional the floor on pedestal and leg models,leave the wood will be producing 9375 BTU's per hour.(7500 BTU x the 4"knockout in the rear of the pedestal or leg kit enclosure 10 lbs./8hrs.=9375 BTU's per hr.) If you put 20 Ibs of wood in place. in your stove for eight hour burn you will get 18,750 BTU's Pedestal Model: Cut or drill a 4" diameter or larger hole per hr.(7500 BTU x 201bs./8hr.=18,750 BTU's per hr.). This is e in the floor anywhere insidethe perimeterof the pedestal.Staple only an example and f based 10 efficiency. reality, a rodent screen in place. your stove should perform in thea 70/o efficiency range. Leg Kit Model:Cut or drill a 4"diameter hole directly below the bottom knockout hole of the bottom enclosure. Connect Experience will give you the right settings for proper combus- enclosure to floor with short 4"diameter pipe. tion and efficient burning. Remember that the proper air inlet This hole must get its air from a ventilated crawl space or setting is affected by variables such as type of wood,outside be extended with ducttothe outdoors(see Figure#2,Page 6). temperature,chimneysize and weatherconditions.With practice, The use of outside combustion air for residential installa- you will become proficient in operating your heater and will tion requires the unit to be secured to the structure to prevent obtain the performance for which it was designed. dislodging of the air duct. On pedestal and leg models, outside air may also be ducted through the 4"diameter hole in the rear of the pedestal or bottom enclosure. OPERATING Note:This unit is notdesigned to be operatedwith thefiring door open. In addition to the obvious hazard of sparks landing on CAUTION: Never use gasoline, gasoline type lantern fuel, combustibles,an open fire door will cause the heater to draw kerosene, charcoal lighter fluid or similar liquids to start or air from the living space and possibly cause suffocation. "freshen up" a fire in this heater. Keep all such liquids well 2.Room air supply-On pedestal and leg models,remove the away from the heater while it is in use. 4"plug from the rear of the pedestal or bottom enclosure.The WARNING: Do not use grates or andirons to elevate the stove will now draw its air from the room through the pedestal fuel. Burn directly on the fire bricks. Replace broken or and into the firebox intake. Consult your local building missing bricks.Failure to do so may create a hazardous code. condition. Note: The living space around the heater must be ventilated Your PACIFIC ENERGY heater is designed for maximum with good air circulation.Anything that may cause a negative overall efficiency at a moderate firing rate. Overfiring is haz- pressure can cause gases or fumes to be pulled into the living ardous and a waste of fuel. Too slow a burn contributes to area. During extremely cold weather, and especially when creosote buildup and lowers combustion efficiency. burning at very slow rates, the upper parts of the exposed chimney may ice up, partially blocking the flue gases. LIGHTING FOR THE FIRST TIME CURING OF THE PAINT FINISH WOOD SELECTION To achieve the best finish the paint on your stove must be baked on. When burning your stove for the first 2-3 times it This heater is designed to burn natural wood only.Higher ef- is very important that the room be well ventilated. Open all ficiency and lower emissions generally result when burning windows and doors.Smoke and fumes caused by the curing air-dried and seasoned hardwood,as compared to softwood or process may cause discomfort to some individuals. to green or freshly cut hardwood. LIGHTING A FIRE Wood should be properly air-dried(seasoned)for six months or more.Wet wood will cause the fire to smoulder and produce WARNING: Never use chemicals or any other volatile liquid large amounts of creosote. Wet wood also produces very to start a fire. little heat and tends to go out often. 1. Adjust air control to"H"(high)position and open door. DO NOT BURN : 2. Place crumpled newspaper in the centre of the heater and Salt water wood* Treated wood criss-cross with several pieces of dry kindling. Add a few Wet or green wood Coal/Charcoal small pieces of dry wood on top. Garbage/Plastic.* Solvents 3. Ignite the paper and close the door. * These materials contain chlorides which will rapidly destroy 4. After the fire has established itself,open the door and add metal surfaces and void warranty. a few small logs.Close door. 5 Do not burn anything but wood. Other fuels, e.g.. charcoal, . Begin normal operation after a good coal base exists and can produce large amounts of carbon monoxide;a tasteless, wood has charred. odourless gas that can kill. Under no circumstances should NORMAL OPERATION you attempt to barbecue in this heater. 1. Set air control to desired setting. If smoke pours down HOW TO TEST YOUR WOOD across the glass (waterfall effect), this indicates you Add a large piece of wood to the stove when it has a good large have shut the control down too soon or you are using bed of coals. It is dry if it is burning on more than one side 8 VISTA and CLASSIC-C 111206-16 too low a setting. As every home's heating needs vary while pulling ashes into the hole. Avoid large charcoal pieces (i.e..insulation,windows, climate,etc.)the proper setting as these still contain heat value. Release handle and push in can only be found by trial and error and should be noted to lock. Ensure ash dump door is properly engaged. Fill the for future burns. cavity with the remaining ash level with the firebox floor. Lift 2. To refuel, adjust air control to "H" (high), and give and pull out ashpan and discard ashes into metal container. the fire time to brighten. Open the door slowly, this will Replace ashpan and ensure it is seated properly. Do not prevent any backpuffing. burn with ash dump door open. Doing so will create a 3. Use wood of different shape, diameter and length (up to hazardous condition. 18" long). Load your wood from side to side and try to placethe logs so that the air can flow between them.Always DISPOSAL OF ASHES use dry wood. Ashes should be placed in a metal container with a tight fit- 4. Do not load fuel to a height or in such a manner that ting lid.The closed container of ashes should be placed on would be hazardous when opening the door. a non-combustible floor or on the ground,well away from all 5. For extended or overnight burns,unsplit logs are preferred. combustible materials,pending final disposal.If the ashes are Remember to char the wood completely on"High"setting disposed of by burial in soil or otherwise locally dispersed, before adjusting air control for overnight burn. they should be retained in closed container until all cinders WARNING:Always keep loading door closed when burning. have thoroughly cooled. Other waste should not be placed This heater is not designed for open door burning. in this container. RESTARTING AFTER EXTENDED OR OVERNIGHT BURNS BAFFLE REMOVAL 1. Open door and rake hot embers towards the front of the heater. Add a couple dry, split logs on top of embers, Chimney connector pipe should be disconnected from stove to close door. clean and inspect chimney.Only if this is not possible should 2. Adjust air control to"H" (high)and in just a few minutes, you removethe baffle.DO NOTOPERATE WITH BAFFLEOR logs should begin burning. INSULATION REMOVED. 3. After wood has charred, reset air control to desired set- ting. REMOVAL 4. To achieve maximum firing rate, set control to"H"(high). Do not use this setting other than for starting or preheating Remove retaining pin at the back top of the firebox,just un- fresh fuel loads. der the baffle. Remove rail extensions in front of the baffle. DO NOT OVERFIRE THIS HEATER:Attempts to achieve Lift baffle up and pull forward to disconnect from the supply heat output rates that exceed heater design specifications tube.Tilt baffle sideways to drop down and remove from fire- can result in permanent damage to the heater and chim- box. Remove insulation to access flue outlet. Inspect gasket ney. between baffle and supply tube. If necessary, replace with gasket #139.5 available from your Pacific Energy dealer. Re-install baffle assembly and insulation by reversing order. PROPER DRAFT Ensure that the insulation is not obstructing the flue outlet or the area above the baffle. 1. Draft is the force which moves air from the appliance up through the chimney. The amount of draft in your chimney depends on the length of the chimney, local geography, nearby obstructions and other factors. 2. Too much draft may cause excessive temperatures in the appliance.An uncontrollable burn or a glowing red stove part or chimney indicates excessive draft. 3. Inadequate draft may cause backpuffing into the room and plugging of the chimney. Smoke leaking into the room through appliance and chimney connectorjoints indicates a inadequate draft. ASH REMOVAL When ever ashes get 3 to 4 inches deep in your firebox,and when fire has burned down and cooled,remove excess ashes. {f.. Leave an ash bed approximately 1 inch deep on the firebox bottom to help maintain a hot charcoal bed. - Optional ash cleanout system: The ash dump handle is - ' located under the ash lip on the left hand side. To operate ash dump, pull handle out 1/2"and turn clockwise.This will unlock the ash dump and allow it to open. Hold handle open 1 1 1 206-1 6 VISTA and CLASSIC-C 9 OPTIONAL BLOWER Automatic: To operate the blower automatically, set the The optional blower kit (# WODC.BLOW) is equipped with rocker switch on the side of the fan housing to"Auto"and set a three prong power cord and may be installed at any time. the speed control to desired setting. This will allow the fan Follow installation instructions supplied with the kit. Route to turn on as the stove heats up to operating temperature. It power supply cord away from heater. will also shut the blower off after the fire has gone out and Electrical rating: 115 volt A.C.-1.02 amps. the unit cooled to below a useful heat output range. Fan output rating: 125 CFM Manual: To manually operate the blower, set the rocker BLOWER OPERATION switch to"Man"and set the speed control to desired setting. Proper blower speed matched with air control setting will en- This will bypass the sensing device and allow full control sure peak performance from your stove.Operate as follows: of the blower. Switching from "Auto" to "Man" or selecting speed may be 1) Air control set to"H"(high),operate blower on"High". done anytime. 2) Air control set between"L"and "H"(low and high),oper- ate blower on"Medium". 3) Air control set to "L" (low), operate blower on "Low". When re-loading fuel,turn off blower for up to 30 minutes to allow stove to reach proper operating temperature. TROUBLESHOOTING PROBLEM CAUSE CURE GLASS IS DIRTY 1.Wood is wet -Use dry wood 2.Turning down air control -Do not turn down until: too soon a)there is a good bed of coals b)the wood is charred -- 3. Draft too low -Improper chimney height and/ or diameter -Chimney plugged or restricted,check flue -Provide outside air for combustion 4. Door gasket leakage -Replace gasket -Check latch EXCESSIVE CREOSOTE BUILDUP See 1,2A above. LOW HEAT OUTPUT 1.Wood is wet -Use dry wood 2. Fire too small -Build a larger fire 3. Draft too low -Chimney plugged or restricted. Inspect and clean WON'T BURN OVERNIGHT 1.Air control is set too high -Set control lower OVERNIGHT 2.Not enough wood -Unsplit wood is preferred for overnight burns 3. Draft too high -Excessive chimney height and/or diameter STOVE WON'T BURN 1. Combustion air supply blocked -Check outside air supply for obstruction -Check that room air cover is removed 2.Draft too low -Chimney plugged or restricted Inspect and clean -Chimney oversized or otherwise unsuitable, Consult dealer 10 VISTA and CLASSIC-C 1 1 1 206-1 6 . CREOSOTE FORMATION AND NEED FOR REMOVAL When wood is burned slowly, it produces tar and other or- CHIMNEY FIRES ganic vapours,which combine with expelled moisture to form The result of excessive creosote buildup is a chimney fire. creosote. The creosote vapours condense in the relatively Chimney fires are dangerous. Chimney inside temperatures cool chimney flue of a slow burning fire. As a result,creosote can exceed 2000' F. This causes much higher than normal residue accumulates on the flue lining. When ignited, this . temperatures in the chimney and on its exterior surfaces.Thus creosote makes an extremely hot fire. The chimney connec- ignition of nearby or touching combustible material is more for and chimney should be inspected at least once every two likely during a chimney fire. Proper clearances are critical months during the heating season to determine if a creosote during such a fire. buildup has occurred. If creosote has accumulated,it should Chimney fires are easy to detect;they usually involve one or be removed to reduce the risk of a chimney fire. more of the following: -Flames and sparks shooting out of the top of the chimney 1. Highest smoke densities occur when a large amount of -A roaring sound wood is added to a bed of hot coals and the air inlet is -Vibration of the chimney closed. The heated wood generates smoke, but without ample air,the smoke cannot burn.Smoke-free,clean burn- IN CASE OF A CHIMNEY FIRE ing requires small fuel loads,two or three logs at a time or 1/4 to 1/2 of fuel load and leaving the air inlet relatively 1. Prepare to evacuate to ensure everyone's safety. Have a wide open, especially during the first 10 to 30 minutes well understood plan of action for evacuation. Have after each loading, when most of the smoke generating a place outside where everyone is to meet. reactions are occurring. After 30 minutes or so, the air inlet can be turned down substantially without excessive 2. Close air inlet on stove. smoke generation. Wood coals create very little creosote- producing smoke. 3. Call local fire department.Have a fire extinguisher handy. Contact your local municipal or provincial fire authority for 2. The cooler the surface over which the wood smoke is further information on how to handle a chimney fire. It is passing, the more creosote will be condensed. Wet or most important that you have a clearly understood plan green wood contributes significantly to creosote formation on how to handle a chimney fire. as the excess moisture that is boiled off cools the fire,mak- ing it difficult for the tars and gases to ignite,thus creating 4. After the chimney fire is out,the chimney must be cleaned dense smoke and poor combustion. This moisture-laden and checked for stress and cracks before starting another smoke cools the chimney, compounding the problem by fire. Also check combustibles around the chimney and the offering the smoke the ideal place to condense. roof. In summary, a certain amount of creosote is inevitable and must be lived with. Regular inspection and cleaning AVOIDING A CHIMNEY FIRE is the solution. The use of dry,seasoned wood and ample There are two ways to avoid chimney fires: combustion air will help to minimize the buildup. 1. Do not let creosote build up to a point where a big chimney fire is possible. 2. Do not have fires in the heater that may ignite chimney fires.These are hotfires,such as when burning household trash, cardboard, Christmas tree limbs, or even ordinary fuel wood;(e.g..with a full load on a hot bed of coals and with the air inlet excessively open.) 111206-16 VISTA and CLASSIC-C 11 REPLACEMENT PARTS - PACIFIC VISTA FIGURE #4a (WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION) ITEM DESCRIPTION PART NO. ITEM DESCRIPTION PART NO. 1 .........SIDE SHIELD, LEFT OR RIGHT.............VIST.2201 ............FIREBRICK, SET..................................BRIC.VISTA 2.........TOP DEFLECTOR...................................VIST.2203 12a .....BRICK RAIL, LEFT...........................................2122 3 .........ASH LIP(c/wtrim&hardware).......ALIP.221001MB 12b.....BRICK RAIL, RIGHT......................................2122.5 ............ASH LIP TRIM, GOLD.................................2210.01 13.......RAIL EXTENSIONS(2 pc.required)................2123 ............ASH LIP TRIM, NICKEL.................................2210.6 14.......BAFFLE INSULATION KIT(3 pc.)...............5068.74 ............ASH LIP HARDWARE..............................ALIP.3211 15.......BAFFLE....................................................VIST.2111 3a .......DOOR CATCH.....................................WODC.1461 15a.....BAFFLE GASKET............................................139.5 4.........GLASS CLAMP SET(4 pc.)....................SSER.142 15b.....BAFFLE PIN.......................................................125 5.........GLASS BAR SET(2 pc.).........................VIST.2125 16.......FLAME SHIELD (c/w nut&bolt)..............VIST.2115 6.........REPLACEMENT GLASS(c/w Tape).....DRVS.2082 17.......AIR SHUTTER ASSEMBLY..:..................VIST4531 7.........DOOR GASKET KIT......................................2082.2 18.......PEDESTAL FRONT COVER 8.........DOOR CASTING,ARCH, BLACK........CAST.VSST ............ASSEMBLY............................................SSER.2075 ............DOOR CASTING,ARCH, GOLD.........CAST.VSGD 19 ......PEDESTAL.....................................VIST.2205WELD ............DOOR CASTING,ARCH, NICKEL........CAST.VSNI 20.......ASH DRAWER ENCLOSURE.................VIST.2219 9.........DOOR HANDLE ASSEMBLY...............WODC.4147 21 .......LEG, BLACK.......................................CAST.LEGST 10.......BOOST MANIFOLD..........................................2105 ............LEG, GOLD......................................CAST.LEGGLD 11a......FIREBRICK, 1 1/2"x 4 1/2"x 1 1/4"...................248 ............LEG, NICKEL.......................................CAST.LEGNI 11b......FIREBRICK, 3"x 4 1/2"x 1 1/4...........................247 22.......ASH BOX(leg model)..............................VIST.2220 11c......FIREBRICK,4"x4 1/2"x 1 1/4".........................246 23.......ASH DUMP ASSEMBLY........................WODC.226 11 d......FIREBRICK, 9"x 4 1/2"x 1 1/4"..................5096.99 24.......ASH BOX(pedestal model).....................VIST.2209 All parts may be ordered from your nearest Pacific Energy dealer. Contact Pacific Energy for the location of the dealer nearest you. FIG.#4a Q 16 \ 14 2 15a 15 13 15b 3a � e. 12a 13 ' 14 3 / I 1 �I 12b 4 6 � � 17 A 1 19 18 o I I I I 24 I 20 9 I 23 10 1I1 21 11a 22 11b 11d 11c 12 VISTA and CLASSIC-C 111206-16 REPLACEMENT PARTS - VISTA CLASSIC FIGURE #4b (WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION) ITEM DESCRIPTION PART NO. ITEM DESCRIPTION PART NO. 1 ......VISTA CLASSIC SIDE SHIELD, L/R....VISC.2251__ 13.... RAIL EXTENSIONS(2 pc. required)...................2123 2......VISTA CLASSIC TOP...........................VISC.2240__ 14....BAFFLE INSULATION KIT(3 pc.)..................5068.74 3......VISTA CLASSIC ASH LIP.......................ALIP.2264__ 15....BAFFLE.......................................................VIST2111 3a ....DOOR CATCH........................................WODC.1461 15a ..BAFFLE GASKET..............................................139.5 4......GLASS CLAMP SET(4 pc.).......................SSER.142 15b..BAFFLE PIN..........................................................125 5......GLASS BAR SET(2 pc.)............................VIST.2125 16....FLAME SHIELD (c/w nut&bolt).................VIST.2115 6......REPLACEMENT GLASS(c/w Tape)........DRVS.2082 •17....AIR SHUTTER ASSEMBLY........................VIST4531 7......DOOR GASKET KIT.........................................2082.2 18....VISTA CLASSIC TOP CLIP.................................2242 8......DOOR CASTING,ARCH, BLACK...........CAST.VSST 19....VISTA CLASSIC TOP BRACKET........................2243 .........DOOR CASTING,ARCH, GOLD............CASTVSGD 20....ASH DRAWER ENCLOSURE....................VIST2219 .........DOOR CASTING,ARCH, NICKEL...........CAST.VSNI 21 ....LEG, BLACK..........................................CAST.LEGST 9 ......DOOR HANDLE ASSEMBLY.................WODC.4147 .........LEG, GOLD........................................CASTLEGGLD 10....BOOST MANIFOLD............................................2105 .........LEG, NICKEL..........................................CASTLEGNI 11a...FIREBRICK, 1 1/2"x 4 1/2"x 1 1/4"......................248 22....ASH BOX....................................................VIST.2220 11b... FIREBRICK, 3"x 4 1/2"x 1 1/4"............................247 23....ASH DUMP ASSEMBLY...........................WODC.226 11c... FIREBRICK,4"x 4 1/2"x 1 1/4"............................246 24....VISTA CLASSIC SIDE SHIELD CLIP..................2252 11d...FIREBRICK, 9"x 4 1/2"x 1 1/4".....................5096.99 25....VISTA CLASSIC SIDE SHIELD BRACKET.........2253 .........FIREBRICK,SET....................................BRIC.VISTA 26....VISTA CLASSIC TRIVET, GOLD...........VISC.GDSCA 12a ..BRICK RAIL, LEFT..............................................2122 .........VISTA CLASSIC TRIVET, NICKEL..........VISC.NISCA 12b..BRICK RAIL, RIGHT........................................2122.5 All parts may be ordered from your nearest Pacific Energy dealer. Contact Pacific Energy for the location of the dealer nearest you. FIG. #4b 16 14 �\ 15a ®��p® \ 15 2 13 15b 6 19 13 12a � 14 12b 1 4 25 24 8 7 � rl 3 24 1 17 20 9 23 10 1I1 21 11a 22 �1 b 11c 11d 111206-16 VISTA and CLASSIC-C 13 A ' ' FIREBRICK INSTALLATION INSTRUCTIONS ENERGY Pacific Vista and Vista Classic This package contains 12 full-size firebricks, as well as 2 various cut-size bricks. If your heater came with an ash cleanout system, or an optional one is being in- stalled, discard one full-size brick. With the heater in the upright position, install firebricks as follows: - First, install 4 full-size firebricks against the rear wall. - Next, install the side firebricks, 2 full-size each side. - Lastly, place 4 full-size on the bottom of the heater. (3 full-size and 2 cut firebricks for heater with an ash cleanout system.) C B USE THESE WITH ASH CLEANOUT SYSTEM. ITEM SIZE PART NUMBER A 1 1/2"X 4 1/2"X 1 1/4" (39 mm x 115 mm x 32 mm) 248.0 B 4" X 4 1/2" X 1 1/4" (102 mm x 115 mm x 32 mm) 246.0 C 9" X 4 1/2" X 1 1/4" (230 mm x 115 mm x 32 mm) 5096.99 14 VISTA and CLASSIC-C 111206-16 SAFETY LABEL - Pacific VISTA and VISTA CLASSIC Warnock Hersey CERTIFIED FOR CANADA AND U.S.A. DO NOT REMOVE THIS LABEL IMAMff LISTED ROOM HEATER,SOLID FUEL TYPE. CM 10 us ALSO FOR USE IN MOBILE HOMES TESTED TO CAN/ULC S627-M93 AND UL 1482-98 PACIFIC VISTA■ REPORT NO.6680(AUG.89) SERIES:C MODEL:VISTA CLASSIC N • INSTALL AND USE IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS. • CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS,INSTALLATION PERMIT AND INSPECTION IN YOUR AREA. • DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE(USA.ONLY). • USE 6 INCH/150MM DIAMETER MINIMUM 24 MSG BLACK OR LISTED CONNECTOR. • CONNECT TO A LINED MASONRY CHIMNEY SUITABLE FOR USE WITH SOLID FUELS. • DO NOT OBSTRUCT THE SPACE BENEATH THE HEATER. • SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED WHEN PASS- ING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING. • DO NOT PASS A CHIMNEY CONNECTOR THROUGH A COMBUSTIBLE WALL OR CEILING. • MINIMUM CLEARANCE BETWEEN SINGLE WALL CHIMNEY CONNECTOR AND COMBUSTIBLE MATERIALS-181NCHES/ 455MM. CLEARANCE MAY BE REDUCED BY THE USE OF LISTED PIPE SHIELDS,WALL PROTECTORS OR OTHER MEANS APPROVED BY LOCAL BUILDING OR FIRE OFFICIALS. MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS RESIDENTIAL INSTALLATION RESIDENTIAL CLOSE CLEARANCE 'ALCOVE MOBILE HOME USING SINGLE WALL CONNECTOR INSTALLATION INSTALLATION INSTALLATION USING DOUBLE WALL CONNECTOR USING USING DOUBLE WALL DOUBLE WALL vERnCAttoxxzclOA KoxrzaxTst coxxecTea V oRRo xxTAl coxxECTOR CONNECTOR CONNECTOR A.SIDEWALL TO UNIT 14 IN.1355 MM 14 IN.1355 MM 12TIN.1305 MM 121N.1305 MM 12 IN.I 305 MM 121N.1305 MM B.BACKWALL TO UNIT 151N.13B1 MM 5°13 IN.1330 MM 7 IN.I 178 MM 7 IN.1178 MM 11 IN.1279 MM 12 IN.1305 MM C.CORNER TO UNIT 10 IN.1254 MM 10 1N.1254 MM 3 1N.176 MM 31N.176 MM N/A 8 IN.1203 MM D.SIDEWALL TO CONNECTOR 231N.1585 MM 23 IN.1585 MM 20.5 IN.1521 MM 20.5 IN.;521 MM 20.5 IN.1/521 MM 20.5 IN.1521 MM E.BACKWALL TO CONNECTOR 18 IN.I 457 MM i'16 IN./406 MM 9.5 IN.1241 MM 9.5 IN. 241 MM 13.5 IN.1343 MM 14.5 IN.1370 MM F.CORNER TO CONNECTOR 19 IN.1483 MM 19 IN.1483 MM 11.51N.1292 MM 11.5 IN.1292 MM N/A 16.51N.1419 MM HORIZONTAL CONNECTOR NOT PERMITTED IN MOBILE HOMES ?f AS TESTED-PIPE SHIELD MAY BE REQUIRED BY LOCAL AUTHORITIES. ' COMBUSTIBLE ALCOVE SIZE:DEPTH-3 FT.1.91 M MAX.,HEIGHT 7 FT./2.1 M MIN.,WIDTH 4 FT.11.2 M MIN. COMBUSTIBLE FLOOR MUST BE PROTECTED BY A CONTINUOUS NON-COMBUSTIBLE MATERIAL EXTENDED TO THE FRONT,SIDES AND BACK AS INDICATED. BACK WALL ADJACENT WALL IN CANADA G. 18 INCHES 1455 MM BACK H. 8 INCHES/200 MM H G H A B E 3 c 1. 8 INCHES 1 200 MM HEATER 3 w- F IN U.S.A. G. 16 INCHES 1405 MM H. 4 INCHES 1102 MM c D a 1. 0 INCHES 10 MM FRONT • COMPONENTS REQUIRED FOR MOBILE HOME AND ALCOVE INSTALLATION:OUTSIDE AIR KIT,AND ONE OF THE FOLLOWING LISTED CONNECTORS: SECURITY MODELS DP OR DC, OLIVER MACLEOD MODEL PV, RYDER MODEL E VENT, SELKIRK METALBESTOS MODEL DS,'METAL FAB MODEL DW,AMERI-TEC MODEL DBSP, INDUSTRIAL CHIMNEY MODEL EXCEL ULTRA-BLACK,OR SIMPSON DURA-VENT MODEL DVL IN COMBINATION WITH ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS: IN CANADA-SECURITY MODEL S2100, OLIVER MACLEOD PROJET MODEL HT 3000, SELKIRK SENTINEL MODEL CF, INDUSTRIAL CHIMNEY MODEL EXCEL 2100, ENERGY VENT COMMANDER 5000. IN USA-SECURITY MODEL ASHT OR S2100, OLIVER MACLEOD MODEL 3103 OR HT 3000, SELKIRK METALBESTOS MODEL SS II, METAL FAB MODEL 2100, AMERI-TEC MODEL HS, INDUSTRIAL CHIMNEY MODEL EXCEL 103HT, SIMP- SON DURA-VENT MODEL DURAIPLUS AND DURA TECH. USE COMPONENTS SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS. ` • APPLIANCE MUST BE INSTALLED WITH PEDESTAL OR LEG KIT ATTACHED. • OPTIONAL COMPONENTS-FAN KIT,FAN ELECTRICAL RATING:115V,60HZ,80WATTS. DO NOT ROUTE POWER CORD BENEATH HEATER. • CAUTION:RISK OF EXCESSIVE TEMPERATURES-KEEP ASH DUMP CLOSED DURING FIRING OF THE HEATER. • OPERATE ONLY WITH FEED DOOR CLOSED. OPEN TO FEED FIRE ONLY. • KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS WELL AWAY FROM HEATER. �����I • REPLACE GLASS ONLY WITH CERAMIC GLASS. C] [ENERGY CANAOA'S FINEST STOVES MANUFACTURED BY: PACIFIC ENERGY FIREPLACE PRODUCTS LTD. PO.BOX 1060,DUNCAN,BC V9L 3Y2 HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS. DATE OF MANUFACTURE U.S.ENVIRONMENTAL PROTECTION J I F M I A M I J J I A I S O N D AGENCY CERTIFIED TO COMPLY WITH 1U98 1 999 2000 2001 2002 2003 DULY,1990,PARTICULATE EMISSION STANDARDS MADE IN CANADA 080801 5050.73 VST1-C-la 1 1 1 206-1 6 VISTA and CLASSIC-C 15 PACIF1 ENERGY PACIFIC ENERGY FIREPLACE PRODUCTS LTD. 2975 Allenby Rd., Duncan, BC V91- 6V8 Phone: 888-715-2398 Web site: www.pacificenergy.net Printed in Canada 16 VISTA and CLASSIC-C 111206-16 V2 Ito Is]10 9 Porcelain Colours and 3 Trivet finishes for all Classic Models GOLD NICKEL METALLIC BLACK MEMO SUNSET RED EBONY COFFEE BEAN BROWN TITANIUM IVORY COPPER FOREST GREEN' ROYAL BLUE' BLACK PEARL' Available as premium colour 4 Finishes for Doors and Legs All Pacific Energy Wood Stoves i (except The Fusion)are customizable in your choice of door and leg finishes. - Available in Gold, Nickel, Metallic Black and Brushed Nickel Doors for the insert models are also available in these four finishes. 4a Two door styles, Arched and Radiant, are available only for the Spectrum and Super series. 2 Finishes for THE FUSION The FUSION is finished in your choice of Brushed Stainless Steel for that contempo- rary style or the sleek look of Metallic Black. OPTIONS Screen Doors Expand your burning season with a Screen Door,sized to fit all Pacific Energy Wood Stoves and Wood Inserts. Black Metallic finish with double handle design for easy placement and removal.Existing door �!may remain in place during Screen Door use. sh System Ash Isposal is clean and easy with a remov- able ash drawer and is a standard feature on all the Classic models and The Fusion. It is available as an optional extra for the VISTA, SUPER 27,SUPER STEP TOP and SUMMIT. Blowers Tempe(blowers Lfeatures cfm variable BUILD-MY STOVE speed for all stove gymodelsvariable speeblower on.Insets. PACIFIC ENERGY WOOD STOVES and INSERTS 7 d� - �� k- - VISTA P `For Heating' Firebox§size Ir' �.5 Cubic ft -MEDIUM ` �; � ! The SUPER Series For Heating up to 20002 ft. • • Firebox size: 2.1 Cubic ft. " ' 4 di 4 b - X; U A ..LARGE The SUMMIT K Series.., For Heating up to 30002 ft. Firebox"'size: 3.0 Cubic ft.. MEDIUM LARGE r `VISTA IN SUPER INSERT SUMMIT INSERT • • •