CERTIFICATE OF OCCUPANCY
No: 35975 Date: 9/27/2012
THIS CERTIFIES that the building RESIDENTIAL ALTERATION
Location of Property: 160 Track Ave, Cutchogue,
SCTM#: 473889 Sec/Block/Lot: 103.-12-2
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this officed dated
8/16/2012 pursuant to which Building Permit No. 37506 dated 9/12/2012
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
Alterations to a Single Family Dwelling
(Partial Garage Conversion)Dining Room, Bedroom,Mudroom and
(Finished Basement)Great Room with Office Area, as applied for.
The certificate is issued to Gardner,John&Gardner, Erin
- (OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO. 37506 9/26/12
PLUMBERS CERTIFICATION DATED
t orize ignat e
TOWN OF SOUTHOLD
�SUFFotX BUILDING DEPARTMENT
y TOWN CLERK'S OFFICE
�y�•� �a�,�? SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit #: 37506 Date: 9/12/2012
Permission is hereby granted to:
Gardner, John & Gardner, Erin
160 Track Ave
Cutchogue, NY 11935
To: Alterations to a Single Family Dwelling;
(Partial Garage Conversion) Dining Room, Bedroom, Mudroom and
(Finished Basement) Great Room with Office Area, as applied for.
At premises located at:
160 Track Ave, Cutchogue
SCTM #473889
Sec/Block/Lot# 103.-12-2
Pursuant to application dated 8/16/2012 and approved by the Building Inspector.
To expire on 3/14/2014.
Fees:
SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $642.80
CO -ALTERATION TO DWELLING $50.00
Total: $692.80
uilding Inspector
TOWN OF SOUTHOLD
�guFFotK�Oa BUILDING DEPARTMENT
N s TOWN CLERK'S OFFICE
oy . SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 37541 Date: 9/24/2012
Permission is hereby granted to:
Gardner, John & Gardner, Erin
160 Track Ave
Cutchogue, NY 11935
Electrical Survey
-pop ;� 5-0
At premises located at:
160 Track Ave, Cutchogue
SCTM # 473889
Sec/Block/Lot# 103.-12-2
Pursuant to application dated 9/24/2012 and approved by the Building Inspector.
To expire on 3/26/2014.
Fees:
ELECTRIC $125.00
Total: $125.00
N
Building Inspector
Form No.6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead.
5. Commercial building,industrial building,multiple residences and similar buildings and installations, a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site plan requirements.
B. For existing buildings (prior to April 9,1957)non-conforming uses,or buildings and"pre-existing"land uses:
1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is
denied,the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificate of Occupancy-New dwelling$25.00,Additions to dwelling$25.00,Alterations to dwelling$25.00,
Swimming pool$25.00,Accessory building$25.00,Additions to accessory building$25.00,Businesses$50.00.
2. Certificate of Occupancy on Pre-existing Building- $100.00
3. Copy of Certificate of Occupancy-$.25
4. Updated Certificate of Occupancy- $50.00
5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00
Date. Je�
New Construction: Old or Pre-existing Building: C (check one)
Location of Property: T a Aa-g— k y- ��41jez Ug
House No. Street 11amlet
Owner or Owners of Property: a
Suffolk County Tax Map No 1000, Section /0 3 Block /-Z Lot
Subdivision ! Filed Map. Lot:
Permit No. Date of Permit. -/a— J a Applicant: Al w y e 2
Health Dept.Approval: Underwriters Approval:
Planning Board Approval:
Request for: Temporary Certificate Final Certificate: (check one)
Fee Submitted: $
Applicant Signa
SOUryolo
Town Hall Annex Telephone(631)765-1802
54375 Main Road Fax(631)765-9502
P.O.Box 1179 roger.richert(cD-town.southold.ny.us
Southold,NY 11971-0959
Zou�m,��'
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICIAL COMPLIANCE
SITE LOCATION
Issued To: John Gardner
Address: 160 Track Ave City: Cutchogue St: NY Zip: 11935
Building Permit* -3-7 ti 0( Section: Block: Lot:
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: elec survey DBA: BJ Electric License No: 2670-me
SITE DETAILS
Office Use Only
Residential X Indoor X Basement X Service Only
Commerical Outdoor X 1st Floor X Pool X
New Renovation 2nd Floor Hot Tub
Addition Survey X Attic Garage X
INVENTORY
Service 1 ph 200a Heat oil Duplec Recpt 52 Ceiling Fixtures 14 HID Fixtures
Service 3 ph Hot Water GFCI Recpt 6 Wall Fixtures 4 Smoke Detectors 3
Main Panel 200a A/C Condenser 1 Single Recpt Recessed Fixtures 11 CO Detectors 1
Sub Panel A/C Blower 1 Range Recpt Fluorescent Fixture 3 Pumps
Transformer Appliances 1-dw Dryer Recpt 1-30 Emergency Fixtures Time Clocks
Disconnect 200a Switches 28 Twist Lock Exit Fixtures TVSS
Other Equipment: 1-exhaust fan, 5-paddle fans, 1-well pump. Swimming pool includes, bonding, 1-h(
pump, 1-pool light, 1-time clock, 1-control panel, 1-GFCI, 1-pump
Notes:
Inspector Signature: Date: Sept 26 2012
81-Cert Electrical Compliance Form.xls
-2 � OF SOpI�O
TOWN OF SOUTHOLD BUILDING DEPT.-
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROU H PLBG.
[ ] FOUNDATION 2ND [ ] 1 ULATION
[ ] FRAMING/STRAPPING [ FINAL
[ ] FIREPLACE A CHIMNEY. [ ] FIRE SAFETY INSPECTION .
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
RE ARKS. ( -
ei L' r
DATE f INSPECTOR �`
SO(/r�o
`3'7 So Co # #
H �
TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION :
[ ] FOUNDATION 1ST [ ] ROUGH.P G.
[ ] FOUNDATION 2ND [ ] IN LATION
[ ] FRAMING/STRAPPING [� FINAL
[ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION- [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
REMARKS:
a
DATE �''� INSPECTOR
FIELD INSPJCCTXgN MORT DATE COMDUyNTS
-ikW -�
FOUNDA11ON(1ST) (")
FOUNDATIQN(2ND)
ROUGH FI2AMTNG& y
PLUMBING
. n
INSULATION PER N.Y. C H
STATE ENERGY COI}E
L
FINAL \ .
-� - _I
ADDITIONAL COMMNTS
• O
Z
. rn
O
z
TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST
BUILDING DEPARTMENT Do you have or need the following,before applying?
TOWN HALL Board of Health
` SOUTHOLD,NY 11971 4 sets of Building Plans
TEL:(631)765-1802 Planning Board approval
FAX:(631)765-9502 7,57� Survey
SoutholdTown.NorthFork.net PERMIT NO. Check
Septic Form
N.Y.S.D.E.C.
Trustees
,�. Flood Permit
Examined 20 Storm-Water Assessment Form
Contact:
Approved 20 Mail to: Nvv 1 1 vW
Disapproved a/c
_J1� Phone:
Ezp'rai'
IjJn
I Building Inspector
AP LICATION FOR BUILDING PERMIT
BLDG.DEPT. Date KVA a 20�
nF cnnrunl D INSTRUCTIONS
a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans,accurate plot plan to scale.Fee according to schedule.
b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or
areas,and waterways.
c.The work covered by this application may not be commenced before issuance of Building Permit.
d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit
shall be kept on the premises available for inspection throughout the work.
e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the
property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an
addition six months.Thereafter,a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or
Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described The
applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit
authorized inspectors on premises and in building for necessary inspections. v
(Signature of applicant or name,if a corporation)
(Mailing address of applicant)
State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder
Name of owner of premises J 0 k a 4 i�r w
(As on the tax roll or latest deed)
If applicant is a corporation,signature of duly authorized officer
(Name and title of corporate officer)
Builders License No.
Plumbers License No.
Electricians License No.
Other Trade's License No.
w1. Location land on which wpkwl be done:1i�0 IE, � c iy
House Number Street Hamlet
County Tax Map No. 1000 Section 0,j Block ' Lot oZ
Subdivision Filed Map No. Lot
2. State existing use and occupancy of premises and intende use and occupancy of proposed construction:
a. Existing use and occupancy 1z S1
b. Intended use and occupancy �('- n 1Ga&& JA bt6& y li(
3. Nature of work(check which applicable):New Building Addition Alteration
Repair Removal Demolition Other Work
�. (Description)
4. Estimated Cost�i Fee
(To be paid on filing this application)
5. If dwelling,number of dwelling units Number of dwelling units on each floor
If garage,number of cars
6. If business,commercial or mixed occupancy,specify nature and extent of each type of use.
7. Dimensions of existing structures,if any:Front �j� I Rear 13 I l P14 Depth
Height IS ' 4/- Number of Stories /
Dimensions of same structure with alterations or additions: Front �;AI —er. Rear
Depth Height Number of Stories
8. Dimensions of entire new construction:Front Rear Depth
Height Number of Stories
q 1 Q /�
9. Size of lot:Front �'d� i 5 Rear %e Depth
10.Date of Purchase Name of Former Owner
11.Zone or use district in which premises are situated a'.'q 0
12.Does proposed construction violate any zoning law,ordinance or regulation?YES_NOXIK
13.Will lot be re-graded?YES_N0 R excess fill be removed from premises?YES_NO'Xj
14.Names of Owner of premises,C �� Address �{ Phone No.
Name of Architect Address Phone No
Name of Contractor Address Phone No.
15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO
*IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY QUIRED.
b.Is this property within 300 feet of a tidal wetland?*YES NO
*IF YES,D.E.C.PERMITS MAY BE REQUIRED.
d�.Provide survey,to scale,with accurate foundation plan and distances to property lines.
17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey.
18.Are there any covenants and restrictions with respect to this property?*YES NO
*IF YES,PROVIDE A COPY.
STATE OF NEW YORK)
SS:
COUNTY
OF )
00,V\(�n "- LAI- being duly swom,deposes and says that(s)he is the applicant
(Name of individuld signing contract)above named,
(S)He is the -Dz SIQL&- f
(Contractor,Agent,Corp to Officer,etc.)
of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be
performed in the manner set forth in the application filed therewith.)
Sworn t1$before me this
�5 Fri day of 20 lc�
�Y�►-� ram.
Notary Public gnature pplicant
CONNIE D. BUNCH
Notary Public,State of Now York
No.01 BU6185050
Qualified in Suffolk County
Commission Expires April 14,
TOWN OF SOUTHOLD PROPERTY REC RD CARD
OWNER STREET . VILLAGE DIST. SUB. LOT
FORMER. OWNER!. ` N E ACR
tf�j�DniG W TYPE OF BUILDING
RE$. �a SEAS. VL. FARM COMM. CB. MICS.. Mkt. Value
LAND IMP. TOTAL DATE REMARKS 3 G .,ta
.L a - Wide,, pd ±
a 11117172, /f a l a-, 7 0 6�a 6 h i c 7 eto4 S 8`
900 ,5'i a a �rr o a i /l�� �j �� ;C3,/? /o��.S'Z c o�Q. ��r e r ee rc� � �• C', �`�,0�0 {�'
89-L1�7lg,o�4'1- �pon� *a 40 �OCDM'r- ` YIC-
t V yoo 3 Qu 0 3 3 9,5- a 2�
3 �Q .yC. goo ,v97
bp t.a. B9 g5 acccsso"
03- L as 523- c'h , k � t urd n2r
oi_ L:' o " oiie- , �r' +o R - ,
Ti Iloble - L°d h ��7
Woodland FRONTAGE ON ROAD
MeadowkwW DEPT #v�
House Pla BULKHEAD
Total
Gi :,u2 1 4 'e`' 2. 'S' '.:5 i� -. 4t ,t4•:. �____�
'- i -9 d N v L4{ ' .Ly P •1■��•� r�•���1r
MENNEN
If
}w. 1 1 ' cfu +t Mfl I y wL `.J Zt. "X _ + ■■■■■■■■■■!■■■■■■■�1■■■■■■�■■■■
fy ■■■MEN
■■■■■■.I■■■■_■_■■■�■iil�l ■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■ ON
C.................■..... ■■...
s
Interior Finish
Fir P
Rooms I st Floor
Recreation i 0-—0M7 Rooms 2,nd Floor
0 Driveway
l
V
JAMES J. DEERKOSKI P.E.
260Deer Drive
Mattituck,NY 11952
(631) 774 7355
Date: September 7, 2012
To: Town of Southold Building Dept
Re: Septic Inspection
Gardner
160 Track Ave.
Cutchogue,NY 11935
To Whom It May Concern:
This letter certifies that the existing Septic System is consisted of a precast I000Gallon
Septic tank and 1- 8' x 12' precast lea ng basin. The system is in good working order
and functions,properly, and is of prope si for a 4 bedroom home. Any questions feel
free to call.
Sind ely,
J es Deerkoski P.E.
ti
�E OF NE-ty,
cb N`S OEe'lp }�A
�e o
z
cP 6 lu
AA�FESS I ONP����
® E C E WE
SEP 1 1 2012
BLDG. DEPT.
TOWN Of SOUTHOLD
o��oF soUr�ol
o
Town Hall Annex Telephone(631)765-1802
54375 Main Road (631)765- 50p
P.O.sox Roo roger.richert(ci�own.souf�io d.nV.us
• �O
Southold,NY 11971-0959 O
C4UNf`I,�
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
APPLICATION FOR ELECTRICAL INSPECTION
REQUESTED BY: Date: �3
r
Company Name:
Name:
License No.:
Address:
Phone No.: S-41
JOBSITE INFORMATION: (*Indicates required information)
*Name:
*Address: (� �/Z - U U7+✓f; if
*Cross Street: 2TILL,L, TyT;L'
*Phone No.:
Permit No.:
Tax Map District: 1000 Section: _ Block: Lot:
*BRIEF DESCRIPTION OF WORK (Please Print Clearly)
XV
—�
(Please Circle All That Apply) �1/v D�
*Is job ready for inspection: CE�S/
O Rough In , 10' Final
*Do you need a Temp Certificate: YES / NO
Temp Information (if needed)
*Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other
*New Service: Re-connect Underground Number of Meters Change of Service Overhead
Additional Information: PAYMENT DUE WITH APPLICATION
82-Request for Inspection Form \
B. P. # 3 71� 5o(o
BUILDING PERMIT EXAMINER CHECKLIST 'Date Submitted: g' Date Reviewed.
Applicant: /VGA`- Owner: 'L
ATd itect(En ineer: l� �� Estimated Cost:
SCTM# 1000 — 0,3— IX— .9-- Subdivision: Zone: Conforming?
Property Address: by TA a44-C r City: Pre COs?
Building Permits (Open/Expired): BP -Z/Go Z- ,Info: BP -Z/C/o Z- , Info:
BP -Z/C/o Z- , Info: BP -Z/C/O Z- ,Info: BP -Z/C/o Z- ,Info:
Single& Separate Search Required? Y o�etermination: — SToRM�n/il•r :_ R_�N FF: o
REQ. Lot Size: ACT. Lot Size: REQ. Lot Cov. ol0` 0 ACT: Lot'C;ov.
REQ. Front ACT. Front R 9Q Side ACT. Side REQ. Rear ' PROP. Rear
REQ. Height. 3 5 1 ACT. Height R E c,P, 9oTH SIDES A
Project Description: a
o
Waterfront? Y o �ead/Blufgt
If yes, water body: Panel# Flood Zone: Bance:
ADDITIONAL APPROVALS REQUIRED QLAN S��� SIGNED, SerILED SuPVtY °fi
Suffol County Health Y of N - If yes, *Bed#: 1� *Date: _/ 1 *Permit#: Town Septic: Y-N
PE, �-7^ If no, certification required: Y or N Received: Y or N By:
NYS DE : PRE-DEC /ins or N Date: _J /_ Permit#: or NJ Letter- Notes:
Southold Trustees: Y pro- Date: /_/ Permit#: or NJ Letter-Notes:
Southold ZBA: Y ore)- Date: _/ / Permit#: -Notes:
Southold Planning: Y o0- Date: -/ /_ Permit#: -Notes:
Town Landmark C of A: Y oGDTE: / /_ *NYS CODE-Compliance \ompliance(page 2): Y or N
CoNTR,,A<T49 11CGNSt AIS,4j3lLITy I-I/4BIL1TY _.•u/o. k^M-lvs CoMPeW,54-r/O / 'N:
Notes: 07 _P-o ( 0
Fee Structure: Calculation: I
Foundation: SF V ` 0« X $ ,TO -$
First Floor: SF + Initial Fee: $ 6�-v 0 ,0 O
Second Floor: SF + Additional Fee ( : $
Other: SF SF X$ t =$
Total: 0 7 SF + Initial Fee: $
t� +Additional Fee
C of o FEE) `K 0 I.� g®
As BUILT FEE "6`-- TOTAL. $ 1 '
NEW YORK STATE CODE COMPLIANCE CHECKLIST
CLIMATIC/GEOGRAPHIC_D SIGN CRITERIA:
Ground Snow Load:20 Wind Speed: 12OMPH Seismic Design Category:B
Weathering: Severe Frost Depth: 36" Termite: M-H Decay: S-M
Design Temp: 11 Iee Shield Underlay: YES Flood Hazards:
USE/OCCUPANCY CLASSIFICATION:
HEIGOUFME AREA: --- -
TYPE OF CONSTRUCTION:
DESIGN CRITERIA: ENGINEERED/PRESCRIl'TIVE
FULL FRAMING DESIGN ELEMENTS: Y/N' {, .
HEADERS: Y/N .WALL STUDS: Y/N GIRDERS: YIN
CEILING JOISTS: YIN FLOOR JOISTS: YIN ROOF RAFTERS: Y/N
LUMBER SPECIES.AND GRADE: YIN
WINDOW AND DOOR SCHEDULE:
•MISSLE TEST REQUIREIIZENTS: Y/N
EGRESS 5.7 S.F.: Y/N ti
LIGHT 8%: Y/N
VENT 4%: Y/N
NAILING/CONSTRUCTION SCHEDULE: Y/N
MEANS OF EGRESS: YIN
PLUMBING RISER DIAGRAM: Y/N
LOCATION OF DIRE PROTECTION EQUIPMENT: YIN
TRUSS DESIGN: YIN
CERTIFICATION: Y/N
.ENERGY CALCS:11�9N (RFSCRECKK) �/!7
TOTAL COAIPLIENCE? Y/N (RETURN TO PAGE ONE)
t
r
y
' now or formerly N-
C.O. Fleet
! L • 199.99
N.46°24'00t
9Toc1GADE FT.TIGB �"
LTI tIn.
N C N
• b
��onsJl�
- now or formerly b
woov DrrcEt. � a
4 0 �
to
• tTxee.o�peueG c�
198.42
p - 5.44°31'40"W
now or formerly
Don ton 8 Martha SOS
now or farm er/y Swi tocko
Gyo �
010
S � '
G -
1 � y
REScheck Software Version 4.4.3 D EC E � W E
Compliance Certificate SEP 1 1 2012
Project Title: Gardner Residence
BLDG.DEPT.
Energy Code: 2010 New York Energy Conservation Construction Code TOWN OF SOUTHOLD
Location: New York County, New York
Construction Type: Single Family
Glazing Area Percentage: 10%
Heating Degree Days: 4910
Climate Zone: 4
Construction Site: Owner/Agent: Designer/Contractor:
160 Track Avenue Nancy Dwyer Design Consulting,Inc.
Cutchogue,NY Southold,NY
Compliance: trade-off
Compliance:0.0%Better Than Code Maximum UA:89 Your UA:89
The%Better or Worse Than Code index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
AssemblyGross Cavity Cont. Glazing UA
• or Door
Perimeter U-Factor
Floor 1:All-Wood JoistlTruss:Over Unconditioned Space 378 19.0 0.0 18
Wall 1:Wood Frame,16"o.c. 505 15.0 0.0 35
Window 1:Vinyl Frame:Double Pane with Low-E 52 0.320 17
Ceiling 1:Flat Ceiling or Scissor Truss 378 19.0 0.0 19
Compliance Statement. The proposed building design described here is consistent with the building plans,specifications,and other
calculations submitted with the permit application.The prop ed building has been designed to meet the 2010 New York Energy Conservation
Construction Code requirements in REScheck Version 4.4.3 n to comply with the mandatory requirements listed in the REScheck Inspection
Checklist.
Name-Title Signa Cre D e
1 ,
�CF NEW YO
�� 5�' 0P
-
z
�Z�FQA o• 07y� P�ci
ROFESS\
Project Title:Gardner Residence Y� �~ Report date: 08/29/12
Data filename:C:\Users\Absolute#2\Documents\REScheck\gardner.rck Page 1 of 4
REScheck Software Version 4.4.3
Inspection Checklist
Energy Code: 2010 New York Energy Conservation Construction Code
Location: New York County,New York
Construction Type: Single Family
Glazing Area Percentage: 10%
Heating Degree Days: 4910
Climate Zone: 4
Ceilings:
❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-19.0 cavity insulation
Comments:
Above-Grade Walls:
❑ Wall 1:Wood Frame, 16"o.c.,R-15.0 cavity insulation
Comments:
Windows:
❑ Window 1:Vinyl Frame:Double pane with Low-E,U-factor:0.320
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Floors:
❑ Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-19.0 cavity insulation
Comments:
Floor insulation is installed in permanent contact with the underside of the subfloor decking.
Air Leakage:
❑ Joints(including rim joist junctions),attic access openings,penetrations,and all other such openings in the building envelope that are
sources of air leakage are sealed with caulk,gasketed,weatherstripped or otherwise sealed with an air barrier material,suitable film or
solid material.
❑ Air barrier and sealing exists on common walls between dwelling units,on exterior walls behind tubs/showers,and in openings between
window/door jambs and framing.
❑ Recessed lights in the building thermal envelope are 1)type IC rated and ASTM E283 labeled and 2)sealed with a gasket or caulk
between the housing and the interior wall or ceiling covering.
❑ Access doors separating conditioned from unconditioned space are weather-stripped and insulated(without insulation compression or
damage)to at least the level of insulation on the surrounding surfaces.Where loose fill insulation exists,a baffle or retainer is installed
to maintain insulation application.
❑ Wood-burning fireplaces have gasketed doors and outdoor combustion air.
❑ Automatic or gravity dampers are installed on all outdoor air intakes and exhausts.
Air Sealing and Insulation:
❑ Building envelope air tightness and insulation installation complies by either 1)a post rough-in blower door test result of less than 7
ACH at 50 pascals OR 2)the following items have been satisfied:
(a)Air barriers and thermal barrier Installed on outside of air-permeable insulation and breaks or joints in the air barrier are filled or
repaired.
(b)Ceiling/attic:Air barrier in any dropped ceiling/soffit is substantially aligned with insulation and any gaps are sealed.
(c)Above-grade walls:Insulation is installed in substantial contact and continuous alignment with the building envelope air barrier.
(d)Floors:Air barrier is installed at any exposed edge of insulation.
(e)Plumbing and wiring:Insulation is placed between outside and pipes.Batt insulation is cut to fit around wiring and plumbing,or
sprayed/blown insulation extends behind piping and wiring.
M Corners,headers,narrow framing cavities,and rim joists are insulated.
(9)Shower/tub on exterior wall:Insulation exists between showers/tubs and exterior wall.
Sunrooms:
Project Title: Gardner Residence Report date: 08/29/12
Data filename: C:\Users\Absolute#2\Documents\REScheck\gardner.rck Page 2 of 4
Sunrooms that are thermally isolated from the building envelope have a maximum fenestration U-factor of 0.50 and the maximum
skylight U-factor of 0.75.New windows and doors separating the sunroom from conditioned space meet the building thermal envelope
requirements.
Materials Identification and Installation:
Materials and equipment are installed in accordance with the manufacturer's installation instructions.
Materials and equipment are identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
Insulation R-values and glazing U-factors are clearly marked on the building plans or specifications.
Duct Insulation:
Supply ducts in attics are insulated to a minimum of R-8.All other ducts in unconditioned spaces or outside the building envelope are
insulated to at least R-6.
Duct Construction and Testing:
Building framing cavities are not used as supply ducts.
All joints and seams of air ducts,air handlers,filter boxes,and building cavities used as return ducts are substantially airtight by means
of tapes,mastics,liquid sealants,gasketing or other approved closure systems.Tapes,mastics,and fasteners are rated UL 181 A or
UL 181B and are labeled according to the duct construction.Metal duct connections with equipment and/or fittings are mechanically
fastened.Crimp joints for round metal ducts have a contact lap of at least 1 1/2 inches and are fastened with a minimum of three
equally spaced sheet-metal screws.
Exceptions:
Joint and seams covered with spray polyurethane foam.
Where a partially inaccessible duct connection exists,mechanical fasteners can be equally spaced on the exposed portion of the
joint so as to prevent a hinge effect.
Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa).
Duct tightness test has been performed and meets one of the following test criteria:
(1)Postconstruction leakage to outdoors test:Less than or equal to 8 cfm per 100 fl2 of conditioned floor area.
(2)Postconstruction total leakage test(including air handler enclosure):Less than or equal to 12 cfm per 100 ft2.
(3)Rough-in total leakage test with air handier installed:Less than or equal to 6 cfm per 100 ft2 of conditioned floor area.
(4)Rough-in total leakage test without air handler installed:Less than or equal to 4 cfm per 100 ft2 of conditioned floor area.
Temperature Controls:
I] Where the primary heating system is a forced air-fumace,at least one programmable thermostat is installed to control the primary
heating system and has set-points initialized at 70 degree F for the heating cycle and 78 degree F for the cooling cycle.
Heat pumps having supplementary electric-resistance heat have controls that prevent supplemental heat operation when the
compressor can meet the heating load.
Heating and Cooling Equipment Sizing:
Additional requirements for equipment sizing are included by an inspection for compliance with the International Residential Code.
For systems serving multiple dwelling units documentation has been submitted demonstrating compliance with 2009 IECC Commercial
Building Mechanical and/or Service Water Heating(Sections 503 and 504).
Circulating'Service Hot Water Systems:
Circulating service hot water pipes are insulated to R-2.
Circulating service hot water systems include an automatic or accessible manual switch to turn off the circulating pump when the
system is not in use.
Heating and Cooling Piping Insulation:
O HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to R-3.
Swimming Pools:
LI Heated swimming pools have an on/off heater switch.
❑ Pool heaters operating on natural gas or LPG have an electronic pilot light.
Timer switches on pool heaters and pumps are present.
Exceptions:
Where public health standards require continuous pump operation.
Where pumps operate within solar-and/or waste-heat-recovery systems.
Heated swimming pools have a cover on or at the water surface.For pools heated over 90 degrees F(32 degrees C)the cover has a
minimum insulation value of R-12.
Project Title: Gardner Residence +� Report date: 08/29/12
Data filename:C:1Users\Absolute#21Documents\RESchecklgardner.rck Page 3 of 4
Exceptions:
Covers are not required when 60%of the heating energy is from site-recovered energy or solar energy source.
Lighting Requirements:
A minimum of 50 percent of the lamps in permanently installed lighting fixtures can be categorized as one of the following:
(a)Compact fluorescent
(b)T-8 or smaller diameter linear fluorescent
(c)40 lumens per watt for lamp wattage—15
(d)50 lumens per watt for lamp wattage>15 and—40
(e)60 lumens per watt for lamp wattage>40
Other Requirements:
Snow-and ice-melting systems with energy supplied from the service to a building shall include automatic controls capable of shutting
off the system when a)the pavement temperature is above 50 degrees F,b)no precipitation is falling,and c)the outdoor temperature is
above 40 degrees F(a manual shutoff control is also permitted to satisfy requirement V).
Certificate:
A permanent certificate is provided on or in the electrical distribution panel listing the predominant insulation R-values;window
U-factors;type and efficiency of space-conditioning and water heating equipment.The certificate does not cover or obstruct the visibility
of the circuit directory label,service disconnect label or other required labels.
NOTES TO FIELD:(Building Department Use Only)
Project Title: Gardner Residence ^�Report date: 08/29/12
Data filename: CAUsers\Absolute#2\Documents\REScheck\gardner.rck Page 4 of 4
2010 New York Energy
Conservation
Construction Code
Certificate
Insulation Rating R.Value
Ceiling/Roof 19.00
Wall 15.00
Floor/Foundation 19.00
Ductwork(unconditioned spaces):
Glass&Door Rating LI-Factor SHIGC
Window 0.32
Door
Cooling'Heating &
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments:
Series IWEIV/VVVTM
• Boilers
M
ti
r S�
� As an ENERGY STAR"Partner,PB Heat,LLC has determined that
diis product meets the ENERGY STAR guidelines br energy efficiency.
Installation ,
Operation fr
Maintenance
Manual
4DT.
PeerlessBoilers.com
TABLEOF •
TABLE OF CONTENTS
USING THIS MANUAL R. _ - �__ _1 5. BURNER SETUP Ft.BOILER
A. INSTALLATION CLEARANCE . . . . . . . . . . . . .1 '_OPERATION_ _ _ _ _ „ 13]
B. SPECIAL ATTENTION BOXES . . . . . . . . . . . .1 A. BURNER INSTALLATION . . . . . . . . . . . . . . .13
B. BURNER STARTUP AND ADJUSTMENT . .13
1. PREINSTALLATION _ _ _ _ r _ 2 C. CHECK BOILER CONTROLS 13
A. CLEARANCES . . . . . . . . . . . . . . . . . . . . . . . .2 D. PURGE AIR FROM THE SYSTEM
B. AIR FOR COMBUSTION AND (WATER BOILERS ONLY) . . . . . . . . . . . . . . .13
VENTILATION . . . . . . . . . . . . . . . . . . . . . . . . .2 E. CLEAN THE BOILER
C. CHIMNEY/VENT AND DRAFT CONTROL . .3 (STEAM BOILERS ONLY) . . . . . . . . . . . . . . .14
D. INSTALLATION SURVEY . . . . .. . . . . . . . . . .3 ---_____�
MAINTENANCE__ _ _ _ _ __ _ 1.6 i
E. PLANNING THE LAYOUT. . . . . . . . . . . . . . . .3 A. GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . .17
----------- ------------- --------------
B. DAILY MAINTENANCE (WITH BOILER
2. BOILER PLACEMENT AND ASSEMBLY 4! OPERATING) . . . . . . . . . . . . . . . . . . . . . . . . .17
A. SETTING THE BOILER . . . . . . . . . . . . . . . . . .4 C. WEEKLY MAINTENANCE (WITH BOILER
B. CONNECTING THE FLUE OUTLET . . . . . . . .4 OPERATING) . . . . . . . . . . . . . . . . . . . . . . . . .17
C. JACKET ASSEMBLY (KNOCKDOWN D. MAINTENANCE OF SAFETY
BOILERS) . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 RELIEF VALVE . . . . . . . . . . . . . . . . . . . . . . .17
E. MONTHLY MAINTENANCE (WITH BOILER
PING AND_CONTROLS -_. _ 6� OPERATING) . . . . . . . . . . . . . . . . . . . . . . . . .17
A. PRESSURE TEST BLOCK ASSEMBLY . . . . .6 F. MAINTENANCE-ANNUAL . . . . . . . . . . . . .17
B. BOILER RETURN CLEARANCE . . . . . . . . . . .6 G. IF A LONG SHUTDOWN IS REQUIRED . . .18
C. WATER BOILER PIPING . . . . . . . . . . . . . . . . .
D. STEAM BOILER PIPING . . . . . . . . . . . . . . . . .67-__BOILER DIMENSIONS ><t RATINGS_ - 79;
E. TANKLESS HEATER OR COVERPLATE . . . . .7
F. CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . .7 (S. _REPAIR PARTS_ _ 21 ;
A. GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
B. WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
USING THIS M
USING THIS MANUAL
A. INSTALLATION CLEARANCE �M Indicates a condition or hazard which
will cause severe personal injury,
Follow the installation instructions provided in this death or major property damage.
manual in the order shown.The order of these Indicates a condition or hazard which
instructions has been set in order to provide the installer am may cause severe personal injury,
with a logical sequence of steps that will minimize death or major property damage.
potential interferences and maximize safety during boiler
installation. Mr Mok Indicates a condition or hazard which
B. SPECIAL ATTENTION BOXES will cause minor personal injury or
property damage.
Throughout this manual you will see special attention
boxes intended to supplement the instructions and make Indicates special attention is needed,
special notice of potential hazards.These categories but not directly related to potential
mean,in the judgment of P13 Heat,LLC: injury or property damage.
1
l
f
PREINSTALLATION
1 . PREINSTALLATION
Read carefully,study these instructions before beginning work.It will save time.Study the included drawings.Save these
instructions for reference.
This boiler must be installed by a qualified contractor.
The boiler warranty can be voided if the boiler is not installed, maintained and serviced correctly.
The equipment shall be installed in accordance with those installation regulations in force in the
local area where the installation is to be made,including the current edition of NFPA-31,Standard
for the Installation of Oil-Burning Equipment,and in Canada, CSA B139,Installation Code for Oil
Burner Equipment.These shall be carefully followed in all cases.Authorities having jurisdiction
shall be consulted before installations are made.
Never burn garbage or paper in the B. AIR FOR COMBUSTION AND
unit,and never leave combustible VENTILATION
material around it.
1. Be certain adequate facilities are available to provide
Do not tamper with boiler controls. air for satisfactory combustion and ventilation.
2. Appliances Located in Unconfined Spaces.
A. CLEARANCES a. For installation in unconfined spaces with
conventional construction and larger areas such
Table 1.1: Clearances from Jacket and Vent System as basements,the supply of air for combustion
and ventilation can usually be considered
Required from Jacket Recommended From Jacket for adequate.
to Combustible Accessibility and Mounting Controls
Construction
3. Appliances Located in Confined Spaces.
Top 5"* 24"to clean flueways. a., All air from inside the building:Provide two
Front 16.5"* 16.5"from jacket due to burner permanent openings communicating directly with
Left 2"* 12"due to burner swing radius. an additional room.If all air for combustion and
ventilation is to come from within the building:
18"on steam with tankless heater or with two openings,one near the ceiling and one near
*
Right 2" Float LWCO. the floor of the boiler room shall be provided
g 9"in area of boiler service switch and with the minimum free area of each opening
junction box. equal to 140 sq.in.per gallon of oil burned.
Rear 2"* 9"for mounting relief valve in standard
location**. b. If all air for combustion and ventilation is to
come from outside the building:two openings,
Vent Pioe (Single Wall)-9"to Combustible Construction. one near the ceiling and one near the floor of the
Clearance may be reduced using methods in NFPA 31. boiler room shall be provided with the minimum
Vent Pioe(Double Wall)-See Manufacturer's Instructions. free area of each opening equal to 35 sq.in.per
*Consider also vent pipe clearance,including distance from edge of gallon of oil burned.
flue outlet to combustible construction(as applicable).
**See dimensional drawing for alternate relief valve location. If ducts are used to convey the air,areas of sq.in.per gallon of oil burned for vertical ducts
Unit may be installed on combustible flooring,provided the or 70 sq. in.per gallon of oil burned for
boiler is not set on carpet and a metal drip pan is placed horizontal ducts are to be provided.Ducts shall
under the appliance. have the same area as the free area of the
openings to which they are connected.
Unit may be installed in a closet with the above clearances.
See also Section B,Air for Combustion and Ventilation.
2
PREINSTALLATION
• • • • • • • For Example:
An oil-fired unit shall be connected Inst llation InstallationwComments
to a flue having sufficient draft at all
times,to assure safe proper No change,but older
operation of the unit. Chimney chimneys(especially unlined
Draft ones)have leaks which
1. Draft Requirement—Minimum draft required in the reduce draft.
vent system is-.03"to-.06"W.C.depending on
boiler model,see Table 7.1 (Section 7).This draft is Boiler
necessary to provide the necessary draft over fire of Design +.Ol" +.04" Required for mandated
-.01"to-.02"W.C.See discussion in paragraph 5 Pressure efficiency increases.
below regarding draft. Drop
2. A barometric draft control is recommended for The old installation would
regulation of overfire draft.Follow manufacturer's have had a higher
instructions to locate and adjust the control. Draft -.03" 0.09, temperature in the chimney
Over Fire [as high as 800 degrees vs.
3. Inspect the existing chimney or vent system.Make 400 degrees F],which would
sure it is in good condition.Inspect chimney liner increase the draft.
and repair or replace if necessary.
The above readings are"cold"readings (before the
4. The vent system and installation must be in boiler and chimney are heated up).
accordance with the current edition of the American
National Standard ANSI/NFPA 211,"Chimneys, Note also that the higher the firing rate on a unit
Fireplaces,Vents,and Solid Fuel Burning which has multiple firing rates,the higher the draft
Appliances,"or applicable provisions of the local required_For example,increasing the firing rate 1/4
building codes.Typical minimum chimney size is gallon may increase the draft loss in a unit by
8"x 8", 15 feet high,unless otherwise allowed by approximately+.01".
code.If the vent system is not sized properly,the
burner may not operate properly.This can cause D. INSTALLATION
poor combustion,sooting and odors to occur.
For new and existing installations, a Water Installation
5. Background Information Regarding Draft: Survey or a Steam Installation Survey is available from
Modern boilers operate with higher efficiencies than P.B. Heat,LLC.The surveys will provide information on
older boilers.Smaller flueways,as well as bars,pins how the boiler works with your specific system and will
and fins are designed into modern boilers to transfer provide an overview of boiler system operation in
as much heat as possible from the hot gases to the general.
water or steam and prevent heat loss up the You can also use this survey to locate system problems
chimney.However,these design features result in which will have to be corrected.To obtain copies of
higher pressure, or draft loss,in the boiler. these Surveys,contact your PB Heat representative or
This draft loss must be taken into account when download'it from PeerlessBoilers.com.
installing an oil boiler into a new or old chimney.
New chimneys are less likely to have poor draft. E. PLANNING THE LAYOUT
However,they must have sufficient draft to support
combustion.A-.06"draft is desirable and preferred. Prepare sketches and notes of the layout of the
Older chimneys may require a replacement liner to installation.Include boiler location,venting system,
have them perform well enough to support existing piping and wiring.Show existing equipment that
combustion. may interfere with installation of new equipment.
3
r -
• �.
.�
1�
�� ' ;
._
�,''�' i
s;
_�
",`-..<
K��,�::�
�,,�,..
ct)
z
GARDNER RE51DENC-- E
N
APPROVED AS NOTED oz o o w
9 �
RENOVATED AREA D TE: � B.P.#� z O
EXISTING TO REMAIN �] Q® O U Q N Z
5ECTON t: c�D - BY: p v
A NOTIFY BUILDING DEPARTMENT AT =
765-1802 8 AM TO 4 PM FOR THE ? az z
FOLLOWING INSPECTIONS: p p Lu
30'-2" OUTLINE OF EXISTING 1. FOUNDATION - TWO REQUIRED g u-
v Q }
ROOF LINE REMAINING FOR POURED CONCRETE DZ W o m
Lc25 c25 2. ROUGH - FRAMING & PLUMBING p D
- 3. INSULATION O Lu
Q
EXISTING 4. FINAL - CONSTRUCTION MUST °L
I—
i 5'-4" 12'o BE COMPLETE FOR C.O.
ALL CONSTRUCTION SHALL MEET THE u= o W
c z PROVIDE 45 MINUTE REQUIREMENTS OF THE CODES OF NEW Z
2668 C9 Q FIRE RATED DOR WITH I YORK STATE. NOT RESPONSIBLE FOR � z
— z SELF CLOSING INGE5 I: o �
PS6068 a N 2868 DOOR Sweep DESIGN OR CONSTRUCTION ERRORS. , < lu
30 N 10 w
EXISTING �j z DOWN O al- = >
DINING ROOM Q =
COMPLY WITH ALL CODES OF Q
6 o
u'S I NEW YORK STATE & TOWN CODES �'
F- MUDROOM
AS REQUIRED _ _ o
BEDROOM KITCHEN NOOK w U
AS EXISTING O EXISTING EXISTING HOLD<NPLANW14110
MATCH FLOOR SOUTH�L BOARD
LINEN HEIGHIfS 2068PANTRY 4GARAGE SOU , LD ES
EXISTING TO REMAIN I _ S.DE
EXISTING RIDGE (��j
266 —O I N U
40G5 S/D
HALL o WALL LEGEND: [L Lu
z PROVIDE FIRE RATED
0O CLOSET DRYWALL 5'-0" IN ON CEILING 4- O WALL TO REMAIN
cLosEr CLOSET o W
ON WALLS COMMON TO GARAGE L—
2 2
GUEST BEDROOM 5/D z GARAGE CONVERSION AREA: Z
U z Q I 2"X 4" FPAME, R 13 INSULATION \ Q
6-O'CEILING HEIGHT z = W/ I LAYER z' GYPSUM BOARD / (�
S/D 0z s s%�GHr N z I GARAGE 5 DES FIRE RATED ON -J Q
Z 5.0%VENT - z O LLL 1
FXREPILACE c j °� cry (V 2"X 4" INTERIOR STUD PARTITION =1
LIVING ROOM 60 O WITH I LAYER 2" GYPSUM BOARD
BEDROOM EXISTING ON EACH SIDE
z
AS EXISTING 'All EXTERIOR WALLS EXISTING 4
t REMAINING; R-13 INSULATION Q/
ENTRY a-s' I I8'-5" WITHIN 2' DRYWALL FINISH SIDE; Q
AS EXISTING EXISTING EGRESS EXISTING IXISTING CEILING ROOF FRAME Ui
STRUCTURE TO REMAIN
3042 3042
— 2- 2"X 5" HEADERS ABOVE ALL
(� WINDOWS * DOORS UNLESS
OTHERWISE NOTED
COVERED STOOP sE A0N OCCUPANCY OR
USE IS UNLAWFUL Orr/ce C-0PY v
— WITHOUT CERTIFICATE z
MASTER BEDROOM OF OCCUPANCY Ln
Ln
O AS EXISTING D F C E � w F W u
CLOSET F I R5T F LO O R LAYOUT Lu J m
SEP 1 1 2012
SCALE:: " = 1 '-O"
BLDG. DEPT. z }
O PLUMBER CERTIFICATION — mivN or sou1HOLD �J
3
O PLUMBING ON LEAD CONTENT ECFORE Q U z
CERTIFICATE OF OCCUFANOY Z z
ALL,PLU"R31NG WASTE o
&WATER LINES N:-ED SOLDER USED IN WATER
:'TESTING BEFORE COVERING SUPPLY SYSTEM CAN, W �
E.ACEFD 2/1 D OF I/LEAD. of N Ew yoR Lu
DEERk �r
+ w
EmE T L r z PAGE:
0 Q
pROFESS\
GARDNER RE51DENCE
Z N
g o -
� o Lu
N
0 z
O o
0 (s) . .
LL Q N Z
RENOVATED AREA
EXISTING TO REMAIN > .. .. .. ..
5EC-1 ON
Lu
A z
J u-j
Q H
C) cn C m
30'-2"
_ OUTLINE OF EXISTING
ROOFLINE REMAINING
C25 C25 17
EXISTING
5'-4" 4 —1 2'-9" W
o
Z
PROVIDE 45 MINUTE w
. . — . — — . — . — . — . — . — . - - - 2GG8 z � FIRE RATED DO RWITH
SELF CLOSING HINGES t Z
PSGOG8 N c 2868 DOOR SWEEP z >
Q LLI
EXISTING DOWN O l Z
DINING ROOM z _ O
V z
N MUDROOM ��� w U
KITCHEN NOOK
EXISTING EXISTING
MATCH FLOOR
HEIGHTS 2068 in PANTRY
GARAGE WALL LEGEND: W
EXISTING TO REMAIN ( 1
_ EXISTING RIDGE
WALL TO REMAIN Q z
4OG8 S� 2GG O I ID- W
O z GARAGE CONVERSION AREA: (s
2"X 4" FRAM E, R-13 1 NSUTATION rr nn
O PROVIDE FIRE RATED R2 W/ I LAYER 2' GYPSUM BOARD V W
O CLOSET DRYWALL 5'-O" IN ON CEILING ,n
'� �r (!Ll)
ON WALLS COMMON TO GARAGE Q ON INTERIOR FIRE RATED ON z v J
2'-2" � GARAGE SIDE
GUEST DEDROUM S� Z z o
rQ 2"X 4" INTERIOR STUD PARTITION —1
8'-d'CEILING HEIG6HT 1 z _ �� WITH I LAYER"' GYPSUM BOARD O
103 50.Fr. °L F "� �' ON EACH SIDE LLJ
U z 9.1%LIGHT N Z I Lo
Z 5.0%VENT Z
EXISTING u� ~ 'ALL EXTERIOR WALLS EXISTING W
LIVING ROOM FIREPLACE (n i N I t REMAINING; R-13 INSULATION r —
WITHIN 2° DRYWALL FINISH SIDE; v Z
EXISTING EXISTING CEILING * ROOF FRAME
STRUCTURE TO REMAIN
2- 2"X 8" HEADERS ABOVE ALL UI
WINDOWS * DOORS UNLESS
EXISTING EGRESS EXISTING OTHERWISE NOTED
3042 3042 c c` A y
I ► I z I�
1s
Lu z
F I KST F LOOK LAYOUT o
J m
SCALE: 4" = I '-O" U z O }
�
-OF
bFDNE�� Q U z
1 fF,Q p z z a
m r
�' ., - (s
r uu
LU
OA o
�O ibNP�"�
PAGE:
I
N
z
g LU o o w
N
O O �
u Q N Z
Z_
SECTION J w
B EGRESS WIINDOW WELL WITH Q ~
TEIR5 TO BE USED AS STEPS; O
SECTION
USE G"X G'"ACQ POSTS OR A
BILCO 5CAFEWELL5Y5TEM
' ANDERSEN 200 SERIES
244GW4040 GLIDING WINDOW;
3- 2"X 8" /ACQ HEADER ABOVE, W
7-0" HEADER HEIGHT z
az
Q w
16-T, EXISTING FOUNDATION U� �
EXISTING POO WALLS TO REMAIN; z Lu
MECHANICALS + EXISTING EXTERIOR II VERIFY FOOTING IN FIELD = Q w
ENTRY STOOP TO REMAIN A55UME- I G"x 8" t 30 O
f BELOW GRADE U U
O
1 EG RE55 N •�i I( z F-
a 2„ "} .,✓ X — R-19 INSULATION
EXISTING PLUMBING
LINE TO REMAIN BEHIND CzO
SETm 3'-4 112" 4-2 1/2^ 10'7 - III N
NEW FRAME WALL
G8 TURN STUDS ON FIAT UNDERFOUNDATION WALL LEGEND: NEW WINDOW BEHIND MEDIA
X W
EXISTING 8" CONCRETE BLOCK 3'-3" BUILT-IN AREA z
FOUNDATION WALL TO REMAIN 29 ° 112 I N ( U I—
R-19 INSULATION WITHIN z o o - E I) GARAGE FOUNDATION t SLAB D-- lU
NEW CONSTRUCTION CEILING THRUOUGHT r I 3 2 X 8 BOX FRAM
cn ` AROUND FINISHED FLODRAREA TO REMAIN
NEW 2"X 4" STEEL STUD W
FRAME WALLS @ 16"O.C. s_s 3_9° Z (�
WITHIN EXISTING FOUNDATION; ?GREAT-ROOM
PROVIDE 2' DRYWALL ON 2GG8 7'-1 O" CEILING HEIGHT 6"X G"AGQ POST
FINISHED SIDE j � 6,_9„ ON SLAB UNDER BOX
FRAME FLOOR JOISTS OUTLINE OF O IR_rINAI_ J
PROVIDE 2- 2"X 6"HEADERS — . — .— . — . STORAGE _ ::_ GALLS REMAINING
TInNI Q
ABOVE ALL DOOR OPENINGS; DERSTAiRS ' II WALLS REMAINING O W
LAUNDRY STORAGE EXISTING DROPPED GIRDER 2668 FIRE RATED BELOW STAB
USE ACQ ON ALL AREAS AGAINST LALLY COLUMNS FOOTINGS w/SELF CLOSING HINGES (ADDITION TO GARAGE
CONCRETE UNHEATED, UNFINISHED o TO REMAIN; BOX AROUND DOOR SWEEP I COMPLETED 1970) Lru (�}
N t FIN15H U II N v z
"NOTE: PROVIDE MECHANICAL z _ O N
VENTILATION 5Y5TEM A, LIGHTING az Q 3 1„ S/D
IN ACCORDANCE WITH THE NEW W I b x II Q
N UTILITIES /STORAGE
YORK STATE RESIDENTIAL CODE _
SECTION R303.1 ; VENT EXHAUST z O m - N UNHEATED, UNFINISHED II V
FAN DUCT TO OUTSIDE 00
W 3 *PROV. 5' FIRE RATED II
DRYWALL ON CEILING
28G N 13'-1 112" OVER FURNACE AREA
m
PROVIDE R-13 INSULATION / 17
WITHIN WALLS COMMON BUILT-IN SHELVES
TO UNFINISHED AREAS i 7-1" y U
si Q 1 3 Z
EXHAUST FAN SECTON
DUCTED TO OUTSIDE �� `7 7 I� z
q z HOM OFFICE N
N 7'-10" CEILING HEIGHT �s -�� , e U O }
2468 7 i
7-7` BASEMENT LAYOUT
�E OF N . s
WATER TANK ' SCALE: 4' = I '-O" P� F�oO�y� ,—^ o
ELECTRIC PANEL L ,
N
.► zAAA
OHO 072��L���a
FE 10 P
PAGE:
2
GENERAL NOTES:
• The information on this set of construction documents is to relate basic design ELECTRICAL NOTES:
intent and framing details. They are intended as a construction aid, not as a
substitute for generally accepted good building practice and are in compliance with • All electrical work to be BOARD OF FIRE UNDERWRITERS approved and to include EXISTING RIDGE 2' PLYWOOD
current New York State building codes. The general contractor is responsible for installation of fixtures [;specifications as indicated on plans. Light fixtures to be supplied by SHEATHING TO REMAIN; NEW (f)
providing standard construction details and procedures to ensure a professionally owner and installed by contractor. GFI outlets required at bathrooms and exterior areas. Install 15# FELT ARCHITECTURAL LU
finished, structurally sound and weatherproof completed product. all outlets as per code. All work is to be done in strict accordance with the New York State Code ASPHALT ROOFING 0
by a licensed electrician. All new switches*outlets to be Levition, standard, supplied It installed �N z
• General contractor to coordinate all subcontractors,scheduling of work and by contractor. Contractor to do all hook-ups as required for bathrooms. �O
interaction between trades. 12 —
• The contractor is responsible for ensuring that all work and construction meets FRAMING NOTES: 5 O O
or exceeds current federal, state and local codes, ordinances and regulations, etc. U — z
These codes are to be considered as part of the specifications for this building plan. • All lumber is to be Douglas Fir#2 or better at 16"on center EXISTING HANGERS W N
(f) Q N Z
• If in the course of construction, a condition exists which disagrees with that as 0 All wood framing in contact with concrete or masonry is to be pressure treated. 'ACQ'designation EXISTING G.J.TO REMAIN R 19 INSULATION
indicated on these drawings,the contractor shall stop work and notify the designer refers to current arsenic free treated wood standards and shall take the place of'CCA' --- ---
U
- t the engineer immediately. Should he fad to follow this procedure and continue work, z
he shall assume all responsibility and liability arismg therefrom. • W
Structural Steel ASTM A36 - FY= 36 KSI PROVIDE�" FIRE RATED _i W
• Dimensions take precedent over scale-DO NOT SCALE DRAWINGS. DRYWALL 5-0" IN ON CEILING t 2' DRYWALL U Q
• All straps, connectors, plates, bolts, nails, etc. are to be galvanized. Designated connectors,strap= N ALL AREAS (f] C m
— ON WALLS COMMON TO GARAGE
• The designer has not been engaged for construction supervision and assumes no etc, on these drawings are my by Simpson unless otherwise indicated. All connectors, straps, etc.are to b
responsibility for construction coordinating with these plans, nor responsibility for nailed/bolted in accordance with the manufacturer's specifications. PANTRY MUDROOM
construction means, methods,techniques, sequences or proceedures or for saftey b
precautions and programs in connection with the work indicated. There are no FLOOR PLAN NOTES: _ GARAGE 2"X 4" INTERIOR EXISTING 2"X 4"STUD WALL @
warranties for a specific use expressed or implied in the use of these plans. EXISTING TO REMAIN STUD PARTITION I G" O.C. W/ K-1 3 INSULATION
Contractor to provide hardwired smoke detectors,with battery back up,and with • Dimensions shall take precedent over scale drawings, DO NOT SCALE DRAWINGS 3- 2"X 8" BOX FRAME 2' CDX PLYWD. SHEATHING W
no intervenin switches, on all floors and in each bedroom.Verify with local code AROUND FINISHED TO REMAIN Z
9 fY ALIGNED FINISH p
requirements as per Section R3 17 New York State Residential Construciton Code. 0 All interior walls to be covered with 2"gyspusm board with metal corner reinforcing. All FLOOR AREA FLOOR HEIGHTS
Install carbon monoxide detectors as per code. drywall products, including gypsum board, screw,Joint compound,tapes t trim shall be U.S. 3i PLYWOOD 5UBFLOOR
Gypsum Co. or approved equal. All Joints shall recieve 3 coats of Joint treatment. Sand final
6"X 6" ACQ POST a EXISTING SILL PLATE, Q
FOUNDATION NOTES: RUNNING UNDER FLOOR 2"X 8" F.J. @ I G"O.G. TERMITE SHEILD t iz
coat to a uniform smooth surface. All walls, ceiling and interior of closets to be taped and ANCHOR BOLTS TO REMAIN Z
spackled, 3 coats, ready for paint. FRAMING R-19 INSULATION = Q W
• Footings shall bear on undisturbed soil within bearing capacity of 1.5 tons/sq.ft. EXISTING GARAGE SLAB O
• Insulation ratings and installation locations as indicated on floor plans t sections TO REMAIN EXISTING BLOCK FOUNDATION U
• Concrete shall be FC = 3,500 P51 @ 28 days q WALL TO FOOTING, 3'-0" BELOW o� _
• All bath it laundryareas, wails and ceilin s adjacent to wet areas to have water resistant GRADE (AS PER 1979 PERMIT)
9 J m GARAGE FOUNDATION z 0 F
• Concrete on 4"sand or gravel fill minimum, with Gx6 - 10/10 welded wire mesh drywall, and provide wonderboard for all areas set to recieve tile. WALLS REMAINING W U
reinforcement. Interior slabs to be placed on 6 mil. stabilized polyethylene vapor BELOW SLAB
barrier. Welded wire mesh is to be placed in the top third of the slab and is to be (ADDITION TO GARAGE
adequately supported by precast concrete bar supports to assure that the reinforcement COMPLETED 1979)
is held in position during concrete placement and finishing.
PLUMBING * HVAC NOTES: LU
• All plumbing work shall be done by a duly licensed plumber and must conform and adhere BUILDING SECTION "A" U
to all New York State building codes 1:saftey requirements.
• Mechanical subcontractor is responsible for adhering to all applicable codes and
SCALE: 4° = I'-O" D- W
saftely requirements. ( 1�
• HVAC subcontractor to fully coordinate system data t-requirements with the
equipment supplier and to provide final system layout drawing and submit it to general contractor, z v J
owner and equipment supplier for final review It,approval. Q
J
OLU
CLIMATIC AND GEOGRAPHIC DE51GN CRITERIA ►L1 (�
WEATHERING SEVERE V z
FROST LINE DEPTH 3'-O" EXISTING FIRST FLOOR AREA PROVIDE DROPPED
TERMITE MODERATE TO HEAVY CEILING TILES THROUGHOUT
DECAY SLIGHT TO MODERATE FINISHED AREAS EXISTING STRUCTURE Q
WINTER DESIGN TEMP. I I TO REMAIN
EXISTING F.J. TO REMAIN R-19 IN ULA ION
ICE SHIELD UNDER- AS PER MANUFACTURER'S
_ NEW EGRESS WINDOW;
LAYMENT REQUIRED SPECIFICATIONS/STATE CODE EXISTING DROPPED
FLOOD HAZARDS GREAT ROOM GIRDEKTO REMAIN 3- 2"X 8"ACQ HEADER
GRADE-EXISTING
NEW 2"X 4" STEEL STUD -r
FRAME WALLS @ I G"O.G. ^ BOX AROUND o
AROUND PERIMETER OF 2° DRYWALL EXISTING LALLYCOLUMN5 ` U
EXISTING FOUNDATION
N z
o
EXISTING FOUNDATION z Ln
AND FOOTINGS TO Lu — t\
EXISTING 4" CONCRETE REMAIN �—
SLAB TO REMAIN Cf)
C)
U z }
BUILDING SECTION "B" z z
SCALE: 4' = I '-O" OF Np-
z z o
5 P S J. bEF��O
0
* >P 4 ILLJ
Y4
b . `; J, w
O , 5 31'
TLA
PAGE:
3