Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
37130-Z
Town of Southold Annex 6/21/2012 g11FFt1(��0? P.O.Box 1179 a 54375 Main Road c+� Southold,New York 11971 dales. CERTIFICATE OF OCCUPANCY No: 35759 Date: 6/21/2012 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 5000 Paradise Point Rd, Southold, SCTM#: 473889 Sec/Block/Lot: 81.-3-1.4 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 3/29/2012 pursuant to which Building Permit No. 37130 dated 4/10/2012 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted electric solar panel system as applied for. The certificate is issued to James,Elyse (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 37130 6/4/12 PLUMBERS CERTIFICATION DATED ized ign re IX ' TOWN OF SOUTHOLD �gUfEol,�c®Gy BUILDING DEPARTMENT TOWN CLERK'S OFFICE �� • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 37130 Date: 4/10/2012 Permission is hereby granted to: James, Elyse 18 Westcott Rd Riverside, CT 06878 To: install a roof mounted electric solar panel system as applied for At premises located at: 5000 Paradise Point Rd, Southold SCTM # 473889 Sec/Block/Lot# 81.-3-1.4 Pursuant to application dated 3/29/2012 and approved by the Building Inspector. To expire on 10/10/2013. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $200.00 CO -ALTERATION TO DWELLING $50.00 ELECTRIC $100.00 Total: $350.00 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL z6 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing" land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant..If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00,Additions to dwelling$25.00,Alterations to dwelling$25.00, Swimming pool$25.00,Accessory building$25.00,Additions to accessory building$25.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. 3 • z S• l 2_ New Construction: Old or Pre-existing Building: ✓ (check one) Location of Property: 5000 0 Ld House No. Street Hamlet Owner or Owners of Property: E k V Se --,a"""'-s Suffolk County Tax Map No 1000, Section Block 3 Lot • O d Subdivision -Pa ra�I Stye I n� Filed Map. 3-7 6 ( Lot: Permit No. Date of Permit. Applicant: re L c L LG Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted:$ 50 Applicant Signature pF SOUTyolo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 • ao roger.richert(a).town.southold.ny.us Southold,NY 11971-0959 olyCUU ,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Elyse James Address: 5000 Paradise Point Road City: Southold St: NY Zip: 11971 Building Permit#: 37130 Section: 81 Block: 3 Lot: 1.004 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Greenlogic License No: 43858-me SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: roof mounted PHOTOVOLTAIC SYSTEM to include 30 Sun Power spr 240 panelE 1 Sun Power spr 7000 inverter with all required grounding and disconnects Notes: Inspector Signature: Date: June 4 2012 81-Cert Electrical Compliance Form.xls ho��OF SO(/ly�lo v TOWN OF SOUTHOLD BUILDING-DEPT. 765-1802 INSPECTION . [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) KELECTRICAL (FINAL) REMARKS: DATE �� INSPECTOR( OF SO(/T�O� cOUMY,�`� TOWN OF.SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSU TION [ ] FRAMING/STRAPPING [ INAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS:- Al DATE INSPECTOR Pacifico Engineering PC Engineering Consulting 700 Lakeland.Ave, Suite 2B r� Ph:631-988-0000 Bohemia, NY 11716 Fax: 631-382-8236 www.pacificoengineering.com engineer@pacificoengineering.com June 4, 2012 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Roy and Elyse James 5000 Paradise Road Southold, NY 11971 I have reviewed the solar energy system installation at the subject address. The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets the requirements of the 2010 NYS Building Code, and ASCE7-05. To my best belief and knowledge, the work in this document is accurate, conforms with the governing codes applicable at the time of submission, conforms with reasonable standards of practice, with the view to the safeguarding of life, health, property and public welfare. Regards, Ralph Pacifico, PE Professional Engineer o� �1EwDEC E � yoR co Q 1 W W ' JUNE 0 R 1g`Z v 2S�b 066 OAP BLDG. Ra if+��r ib ngineer TOWN NY 069 04744306 I.7 3tEP�,7ffDA-7 . . . . cartTs, FOUNDATION(jST)-.. c� FOUNDATION(2ND) G t20UGHFR�NITNC��&' � � PLtMMING INSULATION P91Z N.Y. STATE O.MGY COWS ( 42 Y FINAL , ADDITIONAL.C.OAITYENTS � '2-� `�- too � m C CA °z TOWN OF'SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. 37� Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined 20_ Storm-Water Assessment Form Contact: C rrech Lpo11 C L -C— Approved 0 20 M1ail to:I4,R`j (;[� fr6 PA�i� Disapproved a/c JO(�CE"yawjw ,}m, NN (Mog, Phone: &-3 7 I•S l S�-. Expiration ,201 LMAR Building Inspector 2012 ICATION FOR BUILDING PERMITr�..rrEPT. Date f7eo. �5 20 (2— UTHOLD INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale. Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions, or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws, ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. CY-,-C-_n Log L-C- (Si ature of applicant or name,if a orporation) a S Mr) 12G� 36t �- 069, (Mailing address ot applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Cpr�-�-ra coo� Name of owner of premises l y Se Jc�rY1��3 (As on the tax roll or latest deed) If applicant is corporation, signature of duly authorized officer L4_1 (Narra and title of corporate officer) Builders License No. 40D-D-1 Plumbers License No. Electricians License No. I :5 95 8 Other Trade's License No. 1. Location of land on which proposed work will be don : 500O ?a;,a,Atse House Number Street Hamlet County Tax MTpav,-1AL5P_ No. 1000 Section g Block 3 Lot Subdivision _POt k: Filed Map No. 3 (p Lot 1 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy -S l r\GlL-- LLt4 aLoet t e-tq b. Intended use and occupancy S 1r\q t! -�a�,lu c4 tjef t!►�q 3. Nature of work(check which applicable):New Building Addition Alteration G Repair Removal Demolition Other Work � wlOu.r+ Sodr elqC.;fnC. (Description) SY 4. Estimated Cost 2g1 a-00 Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front 5 3.9 Rear 5 •g Depth Height Number of Stories I Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front 'q S • S ce Rear 14 4 • ?Z Depth I q 4 10. Date of Purchase t Q S3 Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO ✓ 13. Will lot be re-graded? YES NO ✓ Will excess fill be removed from premises? YES NO 14.Names of Owner of premisesP%I Se J�P S Address i o S r Phone No. 2-0 3 '1 �o an Name of Architect�acc{-�co>rrnc�„rr�-cn� p� Address o n Phone No (v 3l� QQ -0000 Name of Contractor 6 vtfcnl-oc L C- l.(-C-- Address " Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES ✓ NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES ✓ NO * IF YES,D.E.C. PERMITS MAY BE REQUIRED.- 16. Provide survey,to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF5rk�4alk) r4L"5lry\ A-1bL C-Ve being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the COa � (Contractor,Agent, Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me thisA ,� .29 day of KA a.,ck-, 20 1 Ndfary PUltf kRBARA A.CASCIOTTA Signature of Applicant Notary Public, State of New York No.01-CA4894969 Qualified in Suffolk Count Commission Expires May 11,t James F.King,President ��rjf SQUTiyO Town Hall Annex 54 Main Road Bob Ghosio,Jr.,Vice-President !lam l0 P.O..Box 1179 Dave Bergen Southold,New York 11971-0959 John Bredemeyer �p Telephone(631)765-1892 Michael.J.Domino ye Fax(631)765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD CERTIFICATE OF COMPLIANCE #0754C Date: June 5, 2012 THIS CERTIFIES that the installation of a roof mounted solar electric system onto the existing dwelling. At 5000 Paradise Point Road Southold New York Suffolk County Tax Map# 81-3-1.4 Conforms to the application for a Trustees Permit heretofore filed in this office Dated February 24,2012 pursuant to which Trustees Administrative Permit#7750A Dated March 21. 2012 was issued and conforms to all of the requirements and conditions of the applicable provisions of law. The project for which this certificate is being issued is for the installation of a roof mounted solar electric system onto the existing dwelling. The certificate is issued to ELYSE JAMES owner of the aforesaid property. )9)1-" 0.'�5r Authorized Signature J UN 12 2012 BLDG. DEPT. TOWN OF SOUTHOLD Town of Southold U Erosion, Sedimentation & Storm-Water Run-off ASSESSMENT FORM PROPERTY LOCATION: S.C.T.M.M THE FOLLOWING ACTIONS MAY REQUIRE THE SUBMISSION OF A 1000 91 .3 �_,I.� STORM-WATER,GRADING,DRAINAGE AND EROSION CONTROL PLAN sb tTT" spec �c jL�o + CERTIFIED BY A DESIGN PROFESSIONAL IN THE STATE OF NEW YORK. SCOPE OF WORK - PROPOSED CONSTRUCTION ULM# / WORK ASSESSMENT Yes No a. What Is the Total Area of the Project Parcels? ' Will this Project Retain All Storm-Water Run-Off (Include Total Area of all Parcels located within LL -� S Generated by a Two(2")Inch Rainfall on Site? / the Scope of Work for Proposed Construction) _f(S.F.rAaes) (This item will include all run-off created by site _✓ ❑ b. What is the Total Area of Land Clearing clearing and/or construction activities as well as all and/or Ground Disturbance for the proposed Site Improvements and the permanent creation of construction activity? (S.F./Aces) Impervious surfaces.) 2 Does the Site Plan and/or Survey Show All Proposed ❑ PROVIDE-BRIEF PROJECT DESCRIPTION (ProvldoAdddanal Pages asMeadad) Drainage Structures Indicating Size&Location?This II Item shall include all Proposed Grade Changes and 1roo4 m OUn-led Slopes Controlling Surface Water Flow. r t��ar a l�-TY 1 t_ Sy�✓'�1 3 Does the Site Plan and/or Survey describe the erosion /❑ and sediment control practices that will be used to v/ control site.erosion and storm water discharges. This item must be maintained throughout the Entire Construction Period. 4 Will this Project Require any Land Filling,Grading or / Excavation where there is a,change to the Natural v/ Existing.Grade Involving more than 200 Cubic Yards _ of Material within any Parcel? 5 Will this Application Require Land Disturbing Activities Encompassing an Area in Excess of Five Thousand (5,000 S.F.)Square Feet of Ground Surface? 6 Is there a Natural Water Course Running through the Site? Is this Project within the Trustees jurisdiction General DEC SWPPP Requirements: or within One Hundred(100')feet of a Welland or El Submission of a SWPPP Is required for all Construction activities involving soil Beach? disturbances of one(1)or more acres; including disturbances of less than one acre that 7 Will there be Site preparation on Existing Grade Slopes � —/ are part of a larger common plan that will ultimately disturb one or more acres of land; which Exceed Fifteen(15)feet of Vertical Rise to t/ Including Construction activities involving soil disturbances of less than one(1)acre where One Hundred(100')of Horizontal Distance? the DEC has determined that a SPDES permit is required for storm water discharges. (SWPPP's Shall meet the Minimum Requirements of the SPDES General Permit 8 Will Driveways,Parking Areas or other Impervious El / for Storm Water Discharges from Construction activity-Permit No.GP-0.10.001.) Surfaces be Sloped to Direct Storm-Water Run-Off ✓ 1.The SWPPP shall be prepared prior to the submittal of the NOI.The NOl shall be Into and/or in the direction of a Town right-of-way? submitted to the Department prior to the commencement of construction activity. 2.The SWPPP shall describe the erosion and sediment control practices and where 9 Will this Project Require the Placement of Material, — required,post-construction storm water management practices that will be used and/or Removal of Vegetation and/or the Construction of any ✓. constructed to reduce the pollutants In storm water discharges and to assure Item Within the Town Right-of-Way or Road Shoulder compliance with the terms and conditions of this permit In addition,the SWPPP shall Area?(This item will NOT Include the Installation of Driveway Aprorm) Identify potential sources of pollution which may reasonably be expected to affect the quality of storm water discharges. NOTE: If Any Answer to Questions One through Nina Is Answered with a Check Mark 3.All SWPPPs that require the post-construction storm water management practice in a Box and the construction site disturbance is between 5,000 S.F.&1 Acre in area, component shall be prepared by a qualified Design Professional Licensed in New York a Storm Water,Grading,Drainage&Erosion Control Plan is Required by the Town of that is knowledgeable In the principles and practices of Storm Water Management. Southold and Must be Submitted for Review Prior to Issuance of Any Building Permit. (NOTE: A Check Mark(,J)and/or Answer for each Question Is Required fora Complete Application) SPATE OF NEW YORK, SI.1 ^I COUNTY OF...........................................SS That I, '`'e�m. A`bP .......being duly sworn,deposes and says that he/she is the applicant for Pennit; ................. ...........C�-......... (Name of Individual signing Document) And that he/she is the ........drr4-vell (Owner,Contractor,Agent,Corporate Officer,eta) Owner and/or representative of the Owner or Owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his knowledge acid belief-,and that the work will be performed in the manner set forth it)the application filed herewith. Sworn to before me this; dayof.41JM`. ...........................�.............2..0°�. ..... ......., ... NoitlyPublic: ...... . .. .... ...}. ............... ......................................... / (Signature of Applicant} FORM - 06110 Notary Public, State of New York No.01-CA4894969 a Qualified in Suffolk Countv r Commission Expires May 11,A 01 S 4-0 / tl� 1 • ��pF SO�jly 1 �'1 ,moo ova ��l• Town Hall Annex Telephone(631)765-1802 54375 Main Road Svc P.O.Box 1179 G Q roner.richert(a tOWn�sout1;01 nv us Southold,NY 11971.0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: . 3a-.��a.ra � e.a sci o-f--�� Date: 3 .2 $ • I Z Company Name: e►I LOCI L c. L_(-- �- Name: olxv- S V La. License No.: 4:5 S S T Address: L{.;-S C ountj 12o kl 39. A Sp,A-r-har+npt-al 'Phone No.: (0 3 ( • ']'1( . S l S Z JOBSITE INFORMATION: (*Indicates required information) *Name: El Sc Ja Prle-s *Address: '5000 Pa,aAtS*-- otn+ o.;J � So ho FJ *Cross Street: *Phone No.: 2 O 3 to Q $-- 10 3-7 ' Permit No.: 1� 3 Tax-Map District: - 1000 Section: g 1- Block: 3 Lot: 1. 00 *BRIEF DESCRIPTION OF WORK(Please Print Clearly) i�Ol7T M0LtrL,L..t -,56, 0- c 1r44VL C3o� Su el Po~ Sir 2 o �t-FT- mvdu.l C t) n Po,,, r`loop.,•, t n ver�e,,- ,F 7 Z00 L0-%+ SP (Please Circle All That Apply) *Is job ready for inspection: YES/® Rough In Final *Do-you need a Temp Certificate: (YW NO Temp Information(if"needed) *Service Size: 1 Phase - 3Phase 100 150 200 300 360 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION pd . . ����� .82=Request for Inspection Form ` U U LOGIC® ENERGY March 28, 2012 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Dear Building Inspector: Please find attached a building permit application on behalf of Elyse James who has engaged us to install a roof-mounted (flat to the roof) solar photovoltaic (PV) electric system for her home at 5000 Paradise Point Road, Southold. In connection with this application, please find attached: • Building Permit application • A Storm Water Assessment Run-off Form • Certificate of Occupancy Application • 2 Surveys of the Premises • Four Engineer's Reports (2 originals and 2 copies) • Four Visio Diagrams of the proposed system • Two spec. sheets of the solar panels (SunPower SPR-240WHT) • Two Spec. sheets of the inverter (SunPower SPR7000m) • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$250 ($200 building permit/$50 CO) • Application for Electrical Inspection with a check for$100 Please let us know if you need anything else in connection with this application. Yours truly, Barbara Casciotta Account Manager GreenLogic LLC 631-771-5152 ext. 117 GREENLOGIC, LLC • www.GreenLogic.com Tel: 877.771.4330 Fax: 877.771.4320 SOUTHAMPTON/CORPORATE: CUTCHOGUE: MANORVILLE: NEW YORK CITY: ROSLYN HEIGHTS: 425 County Rd. 39A 1070 Depot Lane 40 Woodland Avenue 241 6th Avenue #313 200 S. Service Rd., #108 Southampton, NY 11968 Cutchogue, NY 11935 Manorville, NY 11949 New York, NY 10014 Rosyln Heights, NY 11577 REE LOGIC° ENERGY June 8, 2012 The Town of Southold Building Department 54375 Route 25 P.O. Box 117.9 Southold, NY 11971 Re: Building Permit No. 37130 Elyse James 5000 Paradise Point Road, Southold To the Building Inspector: Enclosed please find the Engineer's Certification Letter and the Town of Southold Board of Trustees Certificate of Compliance for Elyse James' solar electric system, which we installed at 5000 Paradise Point Road, Southold. Please arrange to send her the Certificate of Occupancy and close out the building permit. Please let me know if you have any questions about the installation. Sincerely, Barbara Casciotta Account Manager GreenLogic LLC D E C E � W E 631-771-5152 ext. 117 J U N 12 2012 BLDG.DEPT. TOWN OF SOUTHOLD GREENLOGIC, LLC •www.GreenLogic.com Tel: 877.771.4330 Fax: 877.771.4320 SOUTHAMPTON/CORPORATE: CUTCHOGUE: MANORVILLE: NEW YORK CITY: ROSLYN HEIGHTS: 425 County Rd.39A 1070 Depot Lane 40 Woodland Avenue 241 6th Avenue #36 200 S. Service Rd., #108 Southampton, NY 11968 Cutchogue, NY 11935 Manorville, NY 11949 New York, NY 10014 Rosyln Heights, NY 11577 pF SO!/lyOlo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 a� COUNTY,� ' BUILDING DEPARTMENT TOWN OF SOUTHOLD June 11, 2012 GreenLogic LLC 425 County Rd 39A Southampton, NY 11968 RE: James, 5000 Paradise Point Rd, Southold TO WHOM IT MAY CONCERN: The Following Items Are Needed To Complete Your Certificate of Occupancy: **NOTE-Need Certification from an Architect or Engineer certifying the fastening of the panels to the roof system. Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. (contact your electrician) A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 411/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. BUILDING PERMIT: 37130 — Solar Panels I , Survey for: I Sub-division EL YSE 'JAMES Mop Paradise Point, I ° Suff. Section 1" a,�°��°° ti�9A N At Co. Frle No. 3761 I B ayvzew SSOb s�°�$ Town of 620, .6 ap6 So N68. s2 ' SoutholdN6�`5'I•$$ � r p` `.:'.:, u County, New York :..................................... ........ .. .:: Q S ffolk : ® � 00 j �O S.C.T,M.: 1000=081.00=03.00-001.004 o � c �N0 . Q ^e A ��ijQr /:: SCALE:1"=30' Gj may: S r NOTES: 1. AREA = 23,474 S.F. 2. ■ = MONUMENT FOUND, ® = STAKE FOUND. 3, REFERENCE DEED L. 11834 CP 798 P �o�� oo° 4. ELEVATIONS SHOWN HEREON ARE REFERENCED a . TO N.G.V. DATUM (MSL 1929). 5. THIS PARCEL IS WITHIN ZONES SHOWN HEREON AS DILINEATED ON FIRM BOUNDARY MAP NO. cc 36103C0167 G LAST.DATED MAY 04, 1998. o � � s ' FEB. 16. 2012 UPDATE TAX MAP # a, JAN. 5, 2012 UPDATE SUR VEY&TOPO p P. lr r z, S(A� MAR. 03, 2006 UPDATE SURVEY 2 �o� JUNE 01, 2005 REMOVED ROW DATE: JULY 15, 2004 D JOB NO:2004-415 CERTIFIED TO: lb l:`�%; �• ROY JAMES & ELYSE JAMES ......................... �Q .• O rye. No °ems / eJ Cl •/N /L A %• °°0 9 % o�� DAVID H. FOX N,Y,S.L.S. #50234 FOX LAND SURVEYING 64 SUNSET AVENUE WESTHAMPTON BEACH, N.Y. 11978 (631) 288-0022 UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OFSECTION.7209 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYOR'S INKED SEAL OR EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. t CERTIFICATION INDICATED HEREON SHALL RUN ONLY TO THE - PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE TITLE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON AND TO THE I ASSIGNEES OF THE LENDING INSTITUTION. CERTFICATIONS ARE NOT TRANSFERABLE TO ADDITIONAL INSTITUTIONS I OR SUBSEQUENT OWNERS. DWG: 2004-415 3 Strings of 10 SunPower Elyse & Roy James Paradise Point Road 240 W panels, OmSouthold, NY 11971 Each string 2400 watts Array total of 7200 Watts 30 SunFower 240 watt panels All panels to be grounded as per NEC code 2,30 AMP two pole DC switches from panels to inverter F F F • O O SUNPOWER SPR 7000m INVERTER 240 VAC from inverter to a 30 Amp switch near utility meter S U N POWE R E 19 / 240 SOL4R PANEL MAXIMUM EFFICIENCY AND PERFORMANCE i I 4 BENEFITS i Highest Efficiency SunPowerT Solar Panels are the most SERIES efficient photovoltaic panels on the f market today. More Power Our panels produce more power in , the same amount of space—up to 50% more than conventional designs and 100% more than thin film solar panels. Reduced Installation Cost More power per panel means fewer panels per install. This saves both time and money. Reliable and Robust Design Proven materials, tempered front glass, and a sturdy anodized frame allow The SunPoweem 240 Solar Panel provides today's highest efficiency and panel to operate reliably in multiple performance. Utilizing 72 all back-contact solar cells, the SunPower mounting configurations. 240 delivers a total panel conversion efficiency of 19.3%. The panel's I reduced voltage-temperature coefficient, anti-reflective glass and exceptional low-light performance attributes provide outstanding energy t ' delivery per peak power watt. SunPower's High Efficiency Advantage 20% 18% 19% ' 14% i 15% 10% 10% i S/o 0 ' 0% Thin Film Conventional SunPower SunPower I E 18 Series E 19 Series i SPR-240E-WHT D UL us S U N POWE R E 19 / 240 SOLAR PANEL MAXIMUM EFFICIENCY AND MANCE i O. E Electrical Data I-V Curve C i Measured of Standard Test Conditions(STC7:ircadiance of 1000W/m2,AM 1.5,and cell temperance 25°C Peak Power(+5/-3%) Pmax 240 W 7 j t000 w/nf'at so°C [ Efficiency n 19.3% 6 1000 W/m= Rated Voltage Vmpp 40.5 V 5 [ I Q 4 soo w/m' i Rated Current In, 5.93 A I 3 I i Open Circuit Voltage Voc 48.6 V 500W/m2 ( 1 V 2 [ [ i Short Circuit Current Isc 6.30 A ) 1 Maximum System Voltage UL 600 V 200 W/rr1' 0 [ Temperature Coefficients Power(P) -0.38%/K 0 10 20 30 40 50 60 ' Voltage(Voc) -132.5mV/K Voltage M ( Current(Isc) 3.5mA/K i Current/voltage characteristics with dependence on irradiance and module temperature. [ NOCT 45°C+/-2°C ( I Series Fuse Rating 20 A Tested Operating Conditions { F I Y [[p � Temperature -40°F to+185°F(-40°C to+85°C) 1 Mechanical Data Max load 113 psf 550kg/m2(5400 Pa)front—e.g.snow; ( Solar Cells 72 SunPower all-back contact monocrystalline 50 psf 245kg/m2(2400 Pa)front and back—e.g.wind ` Front Glass High transmission tempered glass with Impact Resistance Hail 1 in(25 mm)at 52mph(23 m/s) f j anti-reflective(AR)coating Junction Box IP-65 rated with 3 bypass diodes Warranties and Certifications Dimensions:32 x 155 x 128 (mm) Warranties 25 year limited power warranty Output Cables 1000mm length cables/MulfiContact(MCA)connectors 1 10 year limited product warranty ; Frame Anodized aluminum alloy type 6063 (black) C I Certifications Tested to UL 1703.Cass C Fire Rating k I � i Weight 33.1 lbs. (15.0 kg) 1 f d l I 9 Dimensions I I II 4 Grounding Holes 2X 1200 #}i 2X 200 [47.24]MM 12 06.6 4X 180 (IN) [7.85] [.26] [7.071 1111 2X 30 2X 577 8X 04.2 4X 231 } [1.191 [22.70] [.17] [9.09] I I E 2X1 ..0 i( ?bY [.43] 1 798 754 ] I [31.42] 2X 04.2 6X[29.69] 1 [.171 .6 i i 1559 46 I 4X 322 2X 915 2X 199.5 i [61.39] [1.811 "'lll Ilf�� 112.691 136.02) [7.85] li ( 4X 12 2X 1535 [.47] [60.451 V 1 CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. Visit sunpowercorp.com for details { SUNPOWER and the SUNPOWER I trademarks or registered trademarks of SunPower Co ration. sun oWercor com t agaare ea rP° P P• [ J ©November 2010 sunPower Corporation.Ali rights reserved.specificmions included in this dormheet are subject to change without notice. Document#001-65327 Rev"/LTR_EN t t i 3. Pacifico Engineering PC rr+Ir} Engineering Consulting 700 Lakeland Ave, Suite 26 I _� Ph:631-988-0000 Bohemia, NY 11716 �k_„,,�,�i Ii Fax: 631-382-8236 www.pacificoengineering.com engineer@pacificoengineering.com February 9, 2012 Town of Southold 0 :P APPROVED AS NOTED Building Department E, I ,g I � I 54375 Route 25, P.O. Box 1179 S E I " �— �� � Jp�" D-ATE B.P.# �Z Southold, NY 11971 WM-€��,I ��=JG1E- RT IF I.�,A Subject: Solar Energy Installation for z e q ;� �d /° NUIFYE1U�ILDINGBY-PARTMENT AT Roy and Elyse James F ��;;C,(,,Ui a E'�`9 11��� 5000 Paradise Road 769-1802 8 AM TO 4 PM FOR THE Southold, NY 11971 FOLLOWING INSPECTIONS: 1. FOUNDATION -TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING,PLUMBING, STRAPPING, ELECTRICAL&CAULKING 3. INSULATION 4. FINAL-CONSTRUCTION &ELECTRICAL MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FROR I have reviewed the roofing structure at the subject address. The structure carg �3�r�t� � T11�raTl�ieigFit of S. the roof mounted system.The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2010 NYS Building Code, and ASCE7-05 when installed in accordance with the manufacturer's instructions. Roof Section A mean roof height 22 ft ELECTRICAL pitch 1 in/12 INSPECtl N REQUIRED roof rafter 2x12 rafter spacing 16 in OC Reflected roof rafter span 15.8 ft Table R802.5.1(1) max 23.8 ft The climactic and load information is below: CLIMACTIC AND Ground Wind Live load, point GEOGRAPHIC DESIGN Category Snow Load, Speed,3 pnet30 per pullout Fastener type CRITERIA Pg sec gust, ASCE 7, load,lb mph psf Roof Section A C 20 120 37 379 #14-13x3 DPI Concealer Screw #14-13x5" DPI Concealer Screw ff r. P�eN PAC/,, ; Ralph Pacifico, PE m w� Professional Engineer �Q 06 RalphA Gil ONPal Engineer NY 066182/NJ 24GE04744306 Chimney 4'above roof. 4s. w GREE LOGIC° _1z:21 r_r Fi_ GY ELIMINATING THE COST OF ENERGY 0 CN I><>< ><>< >< >< >< I c O --- 7 DRAWING NUMBER: Paciflco Engineering PC 1 OF 7 PO Box;448,Sayville,NY 11782 631-98MOOD %VWZpacificcengineering.cam SURFACE 1 LAYOUT Ralph Pacifica,Proesional Engneer *Always double check measurements NY Lie D66182 NJ1 Lies 24GE047144300 GreenLogic, LLC—Approved 7.2kW Panel Dimension = 61.39"x31.42" ''�� Layout 30 Sunpower 240w Array Length =368.34 " CF NEW !-p UniRac Solarmount Array Height = 63.84" 4a PACs fy,�\ Roy and Elyse James Azimuth = 305° y g �. 0 \� Surface Dimensions =410"x270" � �� �'"'t 5000 Paradise Point Pitch = 4.5°to the North � d' Southold, NY Scale 3/16" = 1.0' Magic#= N/A ISSUES/SPECIAL INSTRUCTIONS PROJECT COMPONENT COUNT 7 / Sunpower 240w A) Attachment type and count: Co 0 61 • Attachment Point �FESS10r B) Rail type and count: UniRac Sunframe — UniRac Solarmount 2x12"Douglas Fir Rafters 16" Ralph Pacifico Professional Engineer On Center NYS Lid#066182 NJ Lld#249EC4744300 Layout Created By: MVP Date: 1-30-12 Chimney 4'above roof. IJ,fl f�l_i` ELIMINATING THE COST OF ENERGY � X I I 1 l i x �! f I DRAWING NUMBER: Pacifico Engineering PC PO Box 1448,Sayville,NY 11782 2 OF 7 631-988-0000. www.pacific°englneering.com Ralph , Engineer SURFACE 1 ATTACHMENT *Always double check measurements NYLIcPadfico 066182 NJLIcslonal 2 E04744300 GreenLogic, LLC—Approved 7.2kW Layout 30 Sunpower 240w Panel Dimension = 61.39"x31.42" Array Length =368.34 " OF NE YD UniRac Solarmount / 84"Height= 63 PACE Heig . / eN R, Roy and Elyse James Azimuth = 3050 Array 5000 Paradise Point Pitch = 4.5° to the North Surface Dimensions =410"x270" Southold, NY Scale 3/16" = 1.0' Magic# = NIA ` ISSUES/SPECIAL INSTRUCTIONS n PROJECT COMPONENT COUNT Sunpower 240w A)Attachment type and count: 60 Fast Feet. 0 1 • Attachment PointESS10�P B) Rail type and count: UniRac Sunframe UniRac Solarmount Douglas Fir Rafters 16"On C Ralph Pacifico Professional Engineer On Center NYS UeN C66182 NJ Llt?J 249EO4744300 Layout Created By: MVP Date: 1-30-12 ;.. �F�EE�'LOGIC" r G y ELIMINATING THE COST OF ENERGY I i i I i i DRAWING NUMBER: Pacifico Engineering PC PO Box 1448.Sayville,NY 11782 3 OF 7 631-988-0000 www.pacificoengineering.com SURFACE 1 STRINGING * Ralph Pacifica,Professional Engineer 3X10 ON SPR7000M Always double check measurements NYLic(366182 NJLic 24GE04744300 GreenLogic, LLC—Approved 7.2kW Layout 30 Sunpower 240w Panel Dimension = 61.39"x31.42" �NE-�� Array Length =368.34 " OF }- UniRac Solarmount ;�� p Array Height= 63.84" � N PAC/ Roy and Elyse James Azimuth = 3050 ��' Pie u Surface Dimensions =410"x270" 5000 Paradise Point Pitch =4.50 to the North Southold, NY Scale 3/16" = 1.0' Magic#= N/A - / c ISSUES/SPECIAL INSTRUCTIONS PROJECT COMPONENT COUNT ;�t2 ' Sunpower 240w A) Attachment type and count: 0661a2 IV • Attachment Point UniRac Solarmount ESS% B) Rail type and count: UniRac Sunframe o `.RF tiP 2x12'Douglas Fir Rafters 16" Ralph Pacifico Professional Engineer On Center NYS Licq 066182 NJ Llc#249EO4744300 Layout Created By: MVP Date: 1-30-12 ELIMINATING THE COST OF ENERGY 81116" 8 i116" 8 1/16" 6 5/8" 65!8" 6 5/8"--� ( 1 1 I - - DRAWING NUMBER: Pacifica Engineering PC PO Box 1448,Sayville,NY 11782 4 OF 7 631-988-0000 www.paGticoongineciing.com SIDE ELEVATION *Always double check measurements NYUcP066182 NJUc524GE04744 00 GreenLogic, LLC-Approved 7.2'kW Panel Dimension = 61.39"x31.42" �F N� Layout U Sunpower mou Array Length 368.34 ��0 NE y UniRac Solarmount Array Height= 63.84" QN /Fi 0'4 Roy and Elyse James Azimuth = 305° Surface Dimensions =410"x270" 5000 Paradise Point Pitch = 4.5 to the North i Southold, NY Scale 3/16" = 1.0' Magic# = N/A ' W ISSUES/SPECIAL INSTRUCTIONS n W PROJECT COMPONENT COUNT i Sunpower 24ow A)Attachment type and count. j� c�o 066 a �� • Attachment Point P B) Rail type and count: UniRac Solarmount ® UniRac Solarmount ��Ess�0 Douglas Fir Rafters 16" On Center Ralph Pacifico Professional Engineer - On C NYs uar 066182 NJ l.icM 249eo4744300 Layout Created By: MVP Date: 1-30-12 f� �GREE[11 LOG IC' ELIMINATING THE COST OF ENERGY I i JOB MATERIAL LIST Material list q Rail Material List q , Eco-Fasten"Fast Feet"Base Plate .60 Eco-Fasten"Fast Feet"Aluminum Block 30 Eco-Fasten"Fast Feet"EPDM Flashing 60 —�-� #14-130"DPI Concealer Screw 360 #14-13xS"DPI Concealer Screw 120 pACIRPCO �* UniRac 7"Standoff 30 �� Q d ►u I ior � Uj \'S 060 Pv �lopR7FCS5�C� DRAWING NUMBER: 5OF7 MATERIAL LIST *Always double check measurements. GreenLogic, LLC—Approved 7.2 kWI Sunpower 240w Layout 30 Sunpower 240w Panel Dimension = 61.39 x31.42 UniRac Solarmount Array Length = • Attachment Point Roy and Elyse James Azimuth = 305° Array Height= UniRac Solarmount 5000 Paradise Point Road Pitch = 4.5N° Surface Dimensions = Southold, NY Scale 3/16" = 1.0' Magic# = N/A 2x12" Douglas Fir Rafters 16" On Center PROJECT COMPONENT COUNT ISSUES!SPECIAL INSTRUCTIONS A)Attachment type and count: B) Rail type and count: UniRac Solarmount Layout Created By: MVP Date: 1-30-12 G��EENL®GIC", !: ELIMINATING THE COST OF ENERGY Framing_ 202 Douglas Fir rafters spanning 22'6", spaced 16"on center. 2x4 Douglas Fir exterior wall. DRAWING NUMBER: Pacifico Engineering PC PO Box 1448,Sayville,NY 11782 6 OF 7 631-988-0000 vnw f�.paccoengineering.com Ralph.Pacifico,Professional Engineer FRAMING *Always double check measurements NYI COM182 NJ Li 24GE04744300 GreenLogic, LLC—Approved 7.2kW Panel Dimension = 61.39"x31.42" Layout 30 Sunpower 240w i�OF NEW Ya 34 Length =368 n L eg . " !C�, PAC1R '9 UniRac Solarmount Array Roy and Elyse James Azimuth = 305° Array Height= 63.84" �� �Q o ce Surfa Dimensions =410"x270" co cl� 5000 Paradise Point Pitch = 4.5° to the North w Magic# = NIA Southold, NY Scale 3/16" = 1.0' t W _ z a ISSUES 1 SPECIAL INSTRUCTIONS PROJECT COMPONENT COUNT Sunpower 240w 2s 06 8� v A) Attachment type and count. �op o�P • Attachment Point �.ROFEW B) Rail type and count: UniRac Solarmount o UniRac Solarmount 2x12"Douglas Fir Rafters 16" Ralph Pacifica Professional Engineer. On Center NYS LIdI o6s182 NJ Llck 249E047443W Layout Created By: MVP Date: 1-30-12 G; FiN109IC" uwmeier wr:osio[[n[xcT 18"Walkway --------------------------------------- ---� I I I I i I j I I I I - I I I I ' I Pacifico Engineering PC DRAWING NUMBER: Po Box 1448,Sayville,NY 11782 7 OF 7 631-988-0000 www.pacifiecengineedng.com Engineer FAST TRACK PERMIT *Always double check measurements NY Lie 066182NJ Lie 24G1E04744300 GreenLogic, LLC—Approved 7.2kW Panel Dimension = 61.39"x31.42" Layout 30 Sunpower 240w ! NEW yO UniRac Solarmount Array Length = ,!��OF PAC/R ,Q Roy James Azimuth =305° Array Height= /'EQ` ��e� °o 5000 Paradise Point Road Pitch =4.5N° Surface Dimensions = 1*CO � w Southold, NY Scale 3/32" = 1.0' Magic# =N/A PROJECT COMPONENT COUNT ISSUES/SPECIAL INSTRUCTIONS Sunpower240w , A) Number of Roof Layers: 1 p o B) Height above Roof Surface: 7" Attachment Point OFESS\0 C) Materials Used: UniRac Fast foot, UniRac standoff, UniRac Solarm unt.� UniRac Solarmount 2x12"Douglas Fir Rafters 16"On Ralph Pacifico Professional Engineer D) Added Roof Load of PV System: 3.5 PSF Center NYS Lldt 066182 NJ Uc#24SE04744300 Layout Created By: MVP Date: 1-30-12