Loading...
HomeMy WebLinkAbout36819-Z `UFFat� Town of Southold Annex 5/24/2012 �a�O� i COGS i P.O.Box 1179 54375 Main Road oy • o� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 35712 Date: 5/24/2012 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 40 Oriole Dr, Southold, SCTM#: 473889 Sec/Block/Lot: 55.-6-15.15 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 11/4/2011 pursuant to which Building Permit No. 36819 dated 11/17/2011 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof mounted electric Solar Panel System on an existing one family dwelling as applied for The certificate is issued to Roslak,Maureen&Roslak,John (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 36819 5/23/12 PLUMBERS CERTIFICATION DATED 1-0 A�� /U—— �ta A ' ed gnat e TOWN OF SOUTHOLD ��o�svFFut,r�aG BUILDING DEPARTMENT y` TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 36819 Date: 11/17/2011 Permission is hereby granted to: Roslak, Maureen & Roslak, John 40 Oriole Dr Southold, NY 11971 To: Roof mounted electric Solar Panel System as applied for At premises located at: 40 Oriole Dr, Southold SCTM # 473889 Sec/Block/Lot# 55.-6-15.15 Pursuant to application dated 11/4/2011 and approved by the Building Inspector. To expire on 5/18/2013. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $200.00 CO -ADDITION TO DWELLING $50.00 Total: $250.00 Building Inspector Form No.6 TOWN OF SOUTHOLD. BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY. This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new. use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal(S-9 form). . 3. Approval of electrical installation from Board of Fire Underwriters. 4. 'Sworn statement from plumber certifying that the solder used in system contains less than 2110 of 1% lead. . 5. Commercial.building,industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance'from architect or engineer responsible for.the building.. .6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses,or buildings and "Pre-existing" laud uses: 1. Accurate survey.of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed-by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling.$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool $50.00, Accessory building$50.00, Additions to accessory building$S0.00,Businesses $50.00: 2. Certificate of Occupancy on Pre-.existing Building- $100.00 3. Copy of Certificate of.Occupancy.-$_25 4. Updated Certificate of Occupancy- $50.00 5_ Temporary Certificate of Occupancy -Residential $I5.00,Commercial$15.00 Date. ID • 31 • ll New Construction: Old or Pre-existing Building: ' (check one) Location of Property: LID ()V t01'e by • �O(,t�O L C( House No. `- Street Hamlet !Owner or Owners of Property: jok v, ICDS�a K- Suffolk County Tax Map No 1000, Section `J/ Block 11:1 Lot 16 : 15 Subdivision Filed Map. Lot: Permit No. �la ��. Date of Permit. Applicant: la Yf,MLOq 1.C Health Dept.Approval: Underwriters Approval: Planning Board Approval: f Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ 5-0, Uy pplicant Signature *oF sotryolo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 G ao roger.richert(-town.southo Id.ny.us Southold,NY 1 1 97 1-0959 o�yCOUn�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: John Roslak Address: 40 Oriole Drive City: Southold St: NY Zip: 11971 Building Permit#: 36819 Section: 55 Block: 6 Lot: 15.15 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Greenlogic License No: 43858-me SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor .Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures F1 TVSS Other Equipment: roof mounted PHOTOVOLTAIC SYSTEM, to include 45 Sun Power 230 modules 1-SPR-4000,and 1 SPR-6000 inverters,all required combiner boxes and disconnects and,"signs" Notes: Inspector Signature: Date: May 23 2012 81-Cert Electrical Compliance Form.xls OF S0//T�o� cDUNi'l,Nc� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ]�INS ATION [ ] FRAMING/STRAPPING [ il FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: '004 DATE / INSPECTOR G' OF SOUjyo`o o�yco , TOWN OF SOUTHOLD BUILDING DEPT. U 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLOG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE - INSPECTORS Pacifico Engineering PC � 10 Engineering Consulting PO Box 1448 ace Ph: 631-988-0000 11 Sayville, NY 11782 Fax: 631-382-8236 www.pacificoengineering.com engineer@pacificoengineering.com January 24, 2012 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for John Roslak 40 Oriole Drive Southold, NY 11971 1 have reviewed the solar energy system installation at the subject address. The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets the requirements of the 2010 NYS Building Code, and ASCE7-05. To my best belief and knowledge, the work in this document is accurate, conforms with the governing codes applicable at the time of submission, conforms with reasonable standards of practice, with the view to the safeguarding of life, health, property and public welfare Regards, Ralph Pacifico, PE Professional Engineer �pF NEW Y �QN PAC/,,,, �,A CO QQ' w l m r;I J D u v 066182 Rg NYP (�E04744306 Engineer BAN 3 1 2012 SLOG. OEPT. TOWN OF SOUT"4OLD D IN I REP4TT D= CbNIl1 CNTS, FOUN)?AT1ON(1ST) U\ F!?MATION(2N))) hh ROUGH PRAWG PLUN�BIi�1G •. t INSUL•ATXON PIML X.Y. _ a STATE 3Dmmw+CODE 06 ,... �-c��✓ . •FIlVAL . ' �r � ADDITIONAL.COUNTS . • O G - . Cooz TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board pproval t,/* FAX: (631) 765-9502 . � Survey SoutholdTown.NorthFork.net PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined l� ,20 it Storm-Water Assessment Form Contact: Approved l l 20 1 Mail to 25 G2 3-1 A Disapproved a/c "y Phone: t31• 7 I 6'/52 x«—T Expiration 20� D 2 nn Building Inspector ►S U LICATION FOR BUILDING PERMIT NOV - 4 2011 Date G G4 U10-C✓ 31 5201 I DEPT. INSTRUCTIONS a 1OW 'T 4UST be co letely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to sca . ee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within,12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. Gtee e„cOg,C L,LC_ (Signature of applicant or name,if a corporation) 405 C'oun 2C" SoL.L+r r.�, 19 c_ (Mai ing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Name of owner ofpremises J OI'lh �US�a l� (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. qO Z 2 7 Plumbers License No. Electricians License No. 14-3 Other Trade's License No. 1. Locatigo on of land on which ropos�d work will be done: Sax—NiO[cl orlort- House Number Street Hamlet County Tax Map No. 1000 Section S Block Lot Subdivision Filed Map No. Lot I Town of Southold Erosion, Sedimentation & Storm-Water Run-off ASSESSMENT FORM PROPERTY LOCATION: S.c.T.M.u: THE FOLLOWING ACTIONS MAY REQUIRE THE SUBMISSION OF A G1�! DDO SS J5,(S STORM-WATER,GRADING,DRAINAGE AND EROSION CONTROL PLAN District e'cfTon —1l1F cT —Ui CERTIFIED BY A DESIGN PROFESSIONAL IN THE STATE OF NEW YORK. i i SCOPE OF WORK - PROPOSED CONSTRUCTION ITEM# / WORK ASSESSMENT Yes No a. What is the Total Area of the Project Parcels? Will this Project Retain All Storm-Water Run-Off (Include Total Area of all Parcels located within Generated by a Two(Z)Inch Rainfall on Site? the Scope of Work for Proposed Construction) item will a run-off created ✓_ ❑ (S.F./Acres) (This ill Include ff td by site ; b. What is the Total Area of Land Clearing clearing and/or construction activities as well as all and/or Ground Disturbance for the proposed Site Improvements and the permanent creation of construction activity? (S.F./Acres) impervious surfaces.) I PROVIDE BRIEF PROJECT` DESCRIPTION (Provida additional Pages as Needed 2 Does the Site Plan and/or Survey Show All Proposed / Drainage Structures Indicating Size 8r Location?This ✓— ❑ 1 / Item shall include all Proposed Grade Changes and vo tf m Ol tn4e 1 S o lam Slopes Controlling Surface Water Flow. I— 3 Does the Site Plan and/or Survey describe the erosion ❑ �� G �t�5-{e•,n and sediment control practices that will be used to control site erosion and storm water discharges. This Item must be maintained throughout the Entire Construction Period. 4 Will this Project Require any Land Filling,Grading or I Excavation where there is a change to the Natural Existing Grade Involving more than 200 Cubic Yards of Material within any Parcel? 0 5 Will this Application Require Land Disturbing Activities Encompassing an Area in Excess of Five Thousand ❑ r (5,000 S.F.)Square Feet of Ground Surface? I 6 Is there a Natural Water Course Running through the Site? Is this Project within the Trustees jurisdiction M General DEC SWPPP Requirements: or within One Hundred(100')feet of a Wetland or Submission of a SwPPP Is required for all Construction activities involving soil Beach? disturbances of one(1)or more acres; including disturbances of less than one acre that 7 Will there be Site preparation on Existing Grade Slopes are part of a larger common plan that will ultimately disturb one or more acres of land; Which Exceed Fifteen(15)feet of Vertical RlS@ to ❑ including Construction activitles involving soil disturbances of less than one(1)acre where the DEC has determined that a SPDES permit Is required for storm water discharges. One Hundred Fifteen of Horizontal Distance? (SWPPP's Shall meet the Minimum Requirements of the SPDES Gerteral Permit 8 Will Driveways,Parking Areas or other Impervious i for Storm Water Discharges from Construction activity-Permit No.GP-040.001.) Surfaces be Sloped to Direct Storm-Water Run-Off 1.The SWPPP shall be prepared prior to the submittal of the NOI.The NOI shall be into and/or in the direction of a Town right-of-way? submitted to the Department prior to the commencement of construction activity. 2.The SWPPP shall describe the erosion and sediment control practices and where 9 Will this Project Require the Placement of Material, required,post-construction storm water management practices that will be used and/or Removal of Vegetation and/or the Construction of any El — constructed to reduce the pollutants in storm water discharges and to assure Item Within the Town Right-of-Way or Road Shoulder compliance with the terms and conditions of this permit.In addition,the SWPPP shall Area?(Thla Item will NOTinclude the Installation of Driveway aprons.) Identify potential sources of pollution which may reasonably be expected to affect the quality of storm water discharges. NOTE: if Any Answer to Questions One through Nine is Answered with a Check Mark 3.All SWPPPs that require the post-constructlon storm water management practice in a Box and the construction silo disturbance Is between 5.000 S.F.&1 Acre in area, component shall be prepared by a qualified Design Professional Licensed in New York a Storm-Water,Grading,Drainage&Erosion Control Plan is Required by the Town of that Is knowledgeable In the principles and practices of Storm Water Management. Southold and Must be Submitted for Review Prior to Issuance of Any Building Permit. (NOTE: A Cheri Mark(4)and/or Answer for each Question is Required for a Complete Application) STATE OF NEW YORK, , COUNTYOF...........................................(.�.................SS N-e l m bu,k,l•cIL ThatI.................................................................................being duly sworn,deposes and says that he/she is the applicant for Permit, (Name of individual signing Document) /� f p And that he/she is the ............................................. brrT-�V v- ................................................................................................ (Owner,Contractor,Agent,Corporate Officer,etc.) Owner and/or representative of the Owner or Owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his knowledge and belief;and that the work mill be performed in the manner set forth in the application filed herewith. Swom to before me this; *^,, ............................................day of. t. !n�V"I' ' .......,2011.. ........... Notary Public: ............................... �[;L-�� ..... ... ............................................. ............ ........................................................... BARBARAA.CASCIOTTA (SlgnatureotAppllcant) ruiullu, Slate of New York IF FORM - 06110 No. 01-CA4894969 Oualified in Suffolk County Commission Expires May 11, �O��Of S0�/jyo Town Hall Annex Telephone(631)765-1842 54375 Main Road y . hpaxg o ( &JIP.O.Box 1179 rogerrce wn.sou31) toa.nV.us Southold,NY 11971-0959 Q �O r��0l1NIi`i,�� BUILDING DEPARTMENT i TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: �l-,aa,�a ��- Date: I b • 3(• I I Company Name: vcenLoq cc, wG Name: IP�[�c Sk License No.: Address: 4�.5 Ou 20l 3q A-, 5 ,-{-Gta�•,� -{� !(9(og Phone No.: (03 Z l• 5 S�- JOBSITE INFORMATION: (*Indicates required information) *Name: John 2as(a�C *Address: �•}_ y -tole 1�!vwp_ K14hoo *Cross Street: *Phone No.: L4 qq -0-14--7 Permit No.: aj g of Tax-Map District: - 1000 Section: SS. Block:�` Lot: *BRIEF DESCRIPTION OF WORK(Please Print Clearly) '&Cf- IMcun-gd 561a✓ elf cl-ric-_ SLJ,54eM • C4S)S%npowev, mod LALm 1 61) Sunpowev vgomyl _ �� �p'foocxw, �n v,er�s • (Please Circle All That Apply) Is job ready for inspection: YES/��O Rough In Final *Do•you need a Temp Certificate: YES! NO Temp Information(if needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect' Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION l l�l 7_l .82=Request for inspection Form V�r GREENLOGICO ENERGY October 31, 2011 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Dear Building Inspector: Please find attached a building permit application on behalf of John Roslak who has engaged us to install a roof-mounted (flat to the roof) solar photovoltaic (PV) electric system for his home at 40 Oriole Drive, Southold. In connection with this application, please find attached: • A building Permit application • A Storm Water Assessment Run-off Form • A Certificate of Occupancy Application • 2 Surveys of Premises • Four Engineer's Reports (2 originals and 2 copies) • Four Visio Diagrams of the proposed system • Two spec. sheets of the solar panels (SunPower SPR-230WHT) • Two Spec. sheets of the inverter (SunPower SPR4000m and SPR6000m) • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$250 ($200 building permit/$50 CO) • Application for Electrical Inspection with a check for$100 Please let us know if you need anything else in connection with this application. Yours truly, Barbara Casciotta Account Manager GreenLogic LLC 631-771-5152 ext. 117 GREENLOGIC, LLC •www.GreenLogic.com Tel: 877.771.4330 Fax: 877.771.4320 SOUTHAMPTON/CORPORATE: CUTCHOGUE: MANORVILLE: NEW YORK CITY: ROSLYN HEIGHTS: 425 County Rd. 39A 1070 Depot Lane 40 Woodland Avenue 241 6th Avenue #313 200 S. Service Rd.,#108 Southampton, NY 11968 Cutchogue, NY 11935 Manorville, NY 11949 New York, NY 10014 Rosyln Heights, NY 11577 o��pF SO(/T�ol Town Hall Annex ~ Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 cou BUILDING DEPARTMENT TOWN OF SOUTHOLD January 27 2012 John & Maureen Roslak 40 Oriole Dr Southold, NY 11971 TO WHOM IT MAY CONCERN: *NOTE: Building Inspector is u ri Ce cation from an Architect r ineer to certify the faste ing f t ar Panels to the roof syste needs The Following Item(s)Are Needed To Complete Your Certificate of Occupancy: Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. A fee of$50.00 Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. Final Fire Inspection from Fire Marshall. - Bob Fisher Final Landmark Preservation approval. BUILDING PERMIT: 36819 — Solar Panels GREENLOGIC° ENERGY January 27, 2012 The Town of Southold Building Department 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Re: Building Permit No. 368192 John Roslak 40 Oriole Drive, Southold, NY To the Building Inspector: Enclosed please find the Engineer's Certification Letter for John Roslak's solar electric system, which we installed at 40 Oriole Drive, Southold. Please arrange to send him the Certificate of Occupancy and close out the building permit. Please let me know if you have any questions about the installation. Sincerely, Barbara Casciotta Account Manager GreenLogic LLC 631-771-5152 ext. 117 E �n E D �J JAN 3 1 2012 BLDG.DEPT. TOWN OF SOul'"400 GREENLOGIC, LLC'- www.GreenLogi6.com Tel: 877.771.4330 Fax: 877.771.4320 SOUTHAMPTON/CORPORATE: CUTCHOGUE: MANORVILLE: NEW YORK CITY: ROSLYN HEIGHTS: 425 County Rd.39A 1070 Depot Lane 40 Woodland Avenue 241 6th Avenue #3B 200 S. Service Rd.,#108 Southampton, NY 11968 Cutchogue, NY 11935 Manorville, NY 11949 New York, NY 10014 Rosyln Heights, NY 11577 8 C� o,:..1 0 My BU1LDIRIO DE a ^ 7®13-�8o 0_A8 7O a PM`FOR 7HE OCCUPANCY 0R FOLL0YI11Nti INSPECTIONS: t FOUNDATION TWO REQUIRED USE IS UNLAWFUL FORPOUREDCONCREM WITHOUT CERTIFICATE —}�— 2 ROUGH•FMPINp&PLUMBING OF.flv'GUPAPlCY" S INSULATION . S FINAL V-CONSTRUCTIOM MUST -'✓' .I�CbCS$�FOR C.a:`,.:.:. - .. - Aft��CLiNtf C710d SNtlt L7�e�Y,. . - 8f'JE W�]SIfi�S7SS'1T3,�z.-$�1�,:�i�r : 3::• -.,•. OYA =C6fJ8YAUCYION tS: ��,,bba of Yennecalt Park" 1 axSl 1 3 i vrj File No.5167 • Lat49 a.;. L•ot48.: 1 d' �a 13950 ,+N. ?tr�l _ Z hL ,at12 C6 N� t fD 0 Area lylC us- o a�-L1) .k 1A f 1 M r 1 r.?l I r i sS.a m Or Lot 11 Q �o�Qa.g a a o Do a 1 V. ou3E W Z5 _ — , q io_._ > Lf ` (/ L ORIOLE - �8`t �VEX • - a 3F,tt ., c? C_ n CU�tQ � SURVEY FOR -':.' I MAUREEN 'ROSLAK DEC 1a,1990 LOT NO.12,"HIGHPOINT MEADOWS,SECTION TWO nov. 0 _ OCT 17.1990 199 .SQ 0 -j,`_" DATE: JULY 24,1990 '1. s AT SOUTH OLD . •.':!.r,:,;;t ::- 0•-�Fs':'e •SCALE* 1":30 ,.�:;`.2:'•;'.,;-:r. ,1?]V1T3`IOF,iSOlf7 L -,,Cry,;.,:. - NO :-90-0538 SUF�OLY. COUPITY _11fMJ•YORK a uoLu rila+TEzo ALTtaaf.cm 04.0anoN To M13 - - -- Sva9tT o.•:na..nou as m."Djs TE0.As,THE '•Y PLC rARA y}ATt CWCATICN LAD (��C- MA a GOPI ES M 'AAT D I9 vt(NOT a Ansma TN¢LAND �(_( I`q I^ ' 5 v4vCrON'S ED SEAL ORCNa093E0 SEAL SHALL S/ CONSIOCAEa Ta at a VALID TROD COAT s oauA'",Z4 INaCATt0 NCAEo"SMILLL AON avLr lO Y+_ Ce HEALTH OEPAR7GtEN7-OAT&FOR APPRONaL TO CCNSTRUC I An r¢rreDN"a vNan THE Su-Cr IS PAt—PED AMC a MS atw LT TO THE"TLC COM—.OOvfnN- 1 �} D NEAAC9f Oa!$T CMO_"L-OSDaDCL CP U-^TEA 7nlbn Av�L,C_ NCNT.L A" I AND LlMDIaO INSnlDTIDN LISTED A aaT m TAD tS7 LTJE ,noo 4¢cnaT 37_aocA Lorrt�alg.1 NCA¢CN,AND TD ME AS31ORL.OD ME L[NOINO a' A. AAZ RO D14CLLW3G wrmm sac/ECT at MS fnoPLAT( W7TI ruTlp OUAR.NrCES ARC NOT smut EA.pIE nTNEA iNAN r"OSC SROO""%.t04 TO AWI:IONi L.INST?UTICi14.OR•SUOSEOUC NT A rNE,-CA 9O T'AA•O f' UDQ CI' Ti AL iT 'Ta1 TOP 119 OZS :NQ O7a d' T •ILL CAA ro rot 9TA•.a Or 1N8 fuvrOLA GOwir nre.nrw.r , AD19....Kl9 S—tlN e.,ON TAD, on—A.T I.N.. I .1 Pacifico Engineering PC rr+ Engineering Consulting PO Box 1448 i , r,}-. _ Ph: 631-988-0000 Sayville, NY 11782 �� + ; l Fax: 631-382-8236 www.pacificoengineering.com ---=- engineer@pacificoengineering.com October 28,2011 I Town of Southold APPROVED AS NOTED j Building Department rnI 54375 Route 25, P.O. Box 1179 DATE' it (� B.P. # Southold, NY 11971 Subject: Solar Energy Installation for FEE: BY John Roslak NOTIFY BUILDING DEPA TMENT AT 40 Oriole Drive 765-1802 8 AM TO 4 PM FOR THE Southold, NY 11971 FOLLOWING INSPECTInNS 1. FOUNDATION -TWO REQUIRED FOR OCCUPANCY OR 2. ROGH-FR�I NG coNUMI& USE IS UNLAWFUL 3 INSULATION ELECT RICAL a GAU' !ING WITHOUT CERTIFICA _MUST BE COMPLY E F"�R =LEA' OF OCCUPANCy ALL CONSTRUCTION L NILE-THE REQUIREMENTS OF THE LCODES OF NF_V YORK STATE NOT RESPONSIBLE FOR I have reviewed the roofing structure at the subject address. The structu9g%WQPP 996��IR QVg%t of the roof mounted system.The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2010 NYS Building Code, and ASCE7-05 when installed in accordance with the manufacturer's instructions. Roof Section A mean roof height 18 ft ELECTRICAL pitch 12 in/12 INSPECTION REQUIRED roof rafter 2x6 rafter spacing 16 in OC Reflected roof rafter span 4.9 ft Table R802.5.1(1) max 13.3 ft The climactic and load information is below: CLIMACTIC AND Ground wind Live load, point GEOGRAPHIC DESIGN Category Snow Load, Speed,3 pnet30 per pullout Fastener type CRITERIA pg sec gust, ASCE 7, load,lb mph psf Roof Section A C 20 120 33 676 5/16"dia screw, 4-1/2" length I ' I i - I Ralph Pacifico, PE ✓ ly �1., _; Professional Engineer Ralph Pacifiio,ProfessionalEngineer NY 06Ji f NJ-2Wd&744306 LOGIC" ELIMINATING THE COST OF ENERGY 7'Chimney Off of roof. Pacifico Engineering PC PO Box 1448,Sayville,NY 11782 631-988-OM www.pacWw=ngineering.com Ralph Pacffico,Pfessional neer *Always double check measurements NY Lic W6182 NJro Lie 24GE047Engi44300 GreenLogic, LLC—Approved 10.35 kW Layout 45 Sunpower 230w Panel Dimension = 61.39"x31.42" UniRac Sunframe Array Length =471.3 John Roslak Azimuth = 160* Array Height = 188.67" V, 40 Oriole Drive Pitch = 45' Surface Dimensions =495"x237.5" Magic# = 62.14" Southold, NY Scale 3/16" 1.0' ISSUES/SPECIAL INSTRUCTIONS PROJECT COMPONENT COUNT i Sunpower230w A) Attachment type and count: 45 Standoffs. 0 Attachment Point UniRac Sunframe B.) Rail type and count: UniRac Sunframe 2x4"/2x6"Douglas Fir Truss 16" Ralph Pacifico Professional Engineer On Center I NYS Lic#MI 82 NJ Lic#249E04744= Layout Created By: MVP Date: 10-11-11 LOG 1C fly 1.R F�4 ELIMINATING THE COST OF ENERGY 7'Chimney Off of'roof. V1 ANVI /A I AL _LL f ! Pacifico Engineering PC, PO Box 1448,Sayville,NY 11782 631-988-0000 wwmpacificoengii eering.com *Always double check measurements NYLi06s 2 NJicg24GEional 044433M GreenLogic, LLC—Approved 10.35 kW Panel Dimension = 61.39"x31.42" Layout 45 Sunpower 230w UniRac Sunframe Array Length =471.3 John Roslak Azimuth = 160° Array Height= 188.67" Surface Dimensions =495"x237.5" 40 Oriole Drive Pitch = 45° Magic#= 62.14" Southold, NY Scale 3116" = 1.0' ISSUES!SPECIAL INSTRUCTIONS + ` '���/� PROJECT COMPONENT COUNT Sunpower 230w n j A)Attachment type and count: 45 Standoffs. — y S Attachment Point )l J B) Rail type and count: UniRac Sunframe o UniRac Sunframe W'72W Douglas Fir Truss 16" Ralph Pacifico Professional Engineer On Center NYS Lic#86612 NJ Lic#249E047443D0 Layout Created By: MVP Date: 10-11-11 ELIMINATING THE COST OF ENERGY T Chimney Off of roof. �� • �° ;•r ale fit: ;` , �a r Pacifico Engineering PC PO Box 1448,Sayville,NY 11782 2x9 on SPR4000m 631-986-0000 www.pacJcoongineefing.com RalY *Alwa s double check measurements NY NJI EVIneer 3x9 on SPR6000m essional Lie 24UO4744300 GreenLogic, LLC—Approved 10.35 kW Layout 45 Sunpower 230w Panel Dimension = 61.39"x31.42" UniRac Sunframe Array Length =471.3 " ,. -•`V , John Roslak Azimuth = 1600 Array Height = 188.67" 40 Oriole Drive Pitch = 45° Surface Dimensions =495"x237.5" Southold, NY Scale 3/16" = 1.0' Magic#= 62.14" ISSUES/SPECIAL INSTRUCTIONS t•;ti ., / �`.'t,; PROJECT COMPONENT COUNT Sunpower 230w A) Attachment type and count: (1) Attachment Point B) Rail type and count: UniRac Sunframe UniRac Sunframe - 2xV'/2x6"Douglas Fir Truss 16" Ralph Pacifico Professional Engineer On Center NYS Lid#066182 NJ Lld#24BE04744300 Layout Created By: MVP Date: 10-11-11 �"J 'LOGIC0 ELIMINATING THE COST OF ENERGY Framing: Double 2x8 Douglas Fir ridge. 2x4 Douglas Fir rafter spanning 5'from ridge, nailed to a 2x4 Douglas fir plate.Then a 2x6 Douglas Fir plate nailed to a 2x6 Douglas Fir rafter spanning 6'to the 2x4 Douglas Fir knee wall,with a total span 14'9", spaced 16"on center. 2x8 Douglas Fir ceiling joists spaced 16"on center. 2x4 Douglas Fir exterior wall. 1/2" Plywood sheathing. Pacifico Engineering PC PO Box 1448,SaywIlle,NY 11782 631-988-0000 www.paci=ef'!g'wew'rg.com Ralph ,Prof *Always double check measurements NYLicPacifioa 066182 NJ Liescsional 24GE047Engineer44= GreenLogic, LLC—Approved 10.35 kW Layout 45 Sunpower 230w Panel Dimension = 61.39"x31.42" Array Length =471.3 UniRac Sunframe John Roslak Azimuth = 160' Array Height= 188.67" Surface Dimensions =495"x237.5" 40 Oriole Drive Pitch = 45* Southold, NY Scale 3/16" 1.0' Magic#= 62.14" ISSUES SPECIAL INSTRUCTIONS PROJECT COMPONENT COUNT i 1V A) Attachment type and count: Sunpower 230w Attachment Point B) Rail type and count: UniRac Sunframe UniRac Sunframe 2x4!'/2x6"Douglas Fir Truss 16" LRalph:Pacifico Professional Engineer On Center I NYS Lk#066182 NJ Lic#249EO474QOO Layout Created By: MVP Date: 10-11-11 k14" J dhj'`RoslEt 3 Strings of 9 SunPower 40°®,rioleDrlue 230 W panels, Southol0Y11`9571 Each string 2070 wattsr� Array total of 6210 Watts 27 Sunl'owe r�230watt.panels All panels to be grounded as per NEC code 2,30 AMP two pole DC switches from panels to inverter F F F SUNPOWER SPR 6000 INVERTER 240 VAC 240 VAC from inverter to a 30 Amp switch near utility meter J.oh kR;91ak' 2 Strings of 9 SunPower 46=grl0ler Drle. 230 W panels, pfft Each strip 2070 watts Southold NY 1*1971 . Array total of 4140 Watts 18 Sun Power°230 watt panels All panels to be grounded as per NEC code 2,30 AMP two pole DC switches from panels to inverter F F 00 SUNPOWER SPR 4000 INVERTER 240 VAC 240 VAC from inverter to a 30 Amp switch near utility meter S U N POW, E R" 118 230 SOLAR PANEL EXCEPTIONAL EFFICIENCY AND PERFORMANCE i I BENEFITS �■���® o ' Highest Efficiency. SunPoweFm Solar Panels are the most m■®■�� SERIES i efficient photovoltaic panels on the market today. j �■■■®® More Power �■■�■® ���■�® Our panels produce more power in the same amount of space—up to 50% i ■■■■■® L more than conventional designs and ■■■■■� 100% more than thin film solar panels.. ■■■■■■ Reduced Installation Cost ■■■■■� More power per panel means fewer loom No panels per install. This saves both time and money. ' ; Reliable and Robust Design' Proven materials, tempered front glass, TM f and a sturdy anodized frame allow i The SunPower 230 Solar Panel provides today's highest efficiency and ; panel to operate reliably in multiple j performance.Utilizing 72 all back-contact solar cells, the SunPower mounting configurations. i 230 delivers a total panel conversion efficiency of 18.5%. The panel's reduced voltage-temperature coefficient and exceptional low-light performance attributes provide outstanding energy delivery per peak power watt. a SunPower's High Efficiency Advantage 10% e 10% G 5% 7 - 0% ; MG1 Thin Film Conventional SunPower SunPower E 18 Series E 19 Series F SPR-230E-WHT D ( c& { i f i S U N P07WE R" E • EXCEPTIONAL EFFICIENCY AND PERFORMANCE Electrical Data �---- -- I-V Curve I Meomred at standard Test Conditions ISTq:Imodionce of I000w/ms,AM 1.5,and cell temperature 250 C Peak Power(+5/-3%) Pmax 230 W 7,0 I 1000 W/m2 at 50'C Efficiency n 18.5% 6,0 - 1000 W/m2 Rated Voltage V -- 40.5 V 1 5,0 9 mpp 800 W/m? - -- ------ 1 Rated Current - ImPP 5.68 A 4,0 Open Circuit Voltage Voc_ 48.2 V I V 3'0 500 W/m' 1 2,0 1 Short Circuit Current Isc 6.05 A �--- --- — 1,0 200 W/m' t Maximum System Voltage UL 600 V 0,0 + Temperature Coefficients Power(P) •0.38%/K i l- __ _ 0 10 20 30 40 50 60 ! Voltage(Voc) -132.5mV/K Voltage M iCurrent(Isc) 3.5mA/K_ I j Current/voltage characteristics with dependence on irradiance and module temperature. NOCT 45'C+/•2a C I II Series Fuse Rating 20 A -� Tested Operating Conditions _ j Temperature -40a F to+185a F(-40a C to+BY C) [ -- — Mechanical Data- —_ 1 113 psf 550kg/m2(5400 Pa)front-e.g.snow; ; -1i Max load j Solar Cells 72 SunPower all-back contact monocrystalline 50 psf 245kg/m2(2400 Pa)front and back e.g.wind jFront Glass High transmission tempered glass Impact Resistance Hail 1 in(25 mm)at 52mph(23 m/s) _ 3 I Junction Box IP-65 rated with 3 bypass diodes —------- — - ----- i Warranties and Certifications — � k Dimensions:32 x 155 x 128 (mm) -- J - --� Warranties 25 year limited power warranty j 1 Output Cables 1000mm length cables/MultiContact(MC4)connectors --.------- ------------ --- I ' 10 year limited product warranty l Frame Anodized aluminum alloy type 6063 (black) Weight 3 3.1 lbs. (15.0 kg) - - Certifications Tested to UL 1703.Class C Fire Rating - l j Dimensions -- i � I i• j 4 Grounding Holes 2X 1200 I [47.241 I MM 2X 7.8 12 rrj&6 _ 4X 180 t (IN) [7.85] [.26] [7.071 2X 30 2x 577 8X in4.2 4X 231 kp —L [22.701 .L.'_ j [.17] — [9.09] 1 r 2x 11.0 1.431 798 6X 754 I.. [31.421 L_2X 04.2 f29.691 I.17] 1559 46 14X 322 Imo_2X 915 --L 2X 199.5 1 f [61.39] ���111 [1.81] '� lll' Ij [12.69JI [3 "'lll� [7.85] ' 4X 12 , 2X 1535 [.471 �'� [60.45] i CAUTION: READ SAFETY AND INSTALLATION IN51r`?UCTIiONIS BEFORE USING THE PRODUCT. Visit sunpowercorp.com for detaiis SUNPOWER and the SUNPOWER logo are trademarks or registered trademarks of SunPower Corporation. sunpoWercorp.com 0 February 2010 SunPower Corporation.All rights reserved.Specifications Included in this datash mt are subject to change without notice. Document#001-60680 Rev—/LTR EN 1 , jI 3000m and 111 S U N POWE R" EXCEPTIONAL RELIABILITY AND PERFORMANCE BENEFITS Reliable and Robust Design Proven track record for durability and longevity High Efficiency I' Weighted CEC efficiency over 95% and peak efficiency over 96% i Reduced Installation Cost Integrated DC disconnect with fuses f _ lowers material costs and labor requirements Attractive Aesthetics Integrated disconnect eliminates need ;. for visible conduits to inverter Ideal Output ` k. Ideal for residential applications " SunPowerlm 3000m and 4000m Inverters offer exceptional reliability and superior performance. Innovative design and advanced testing are combined to create a durable inverter for optimal system performance over the long term. Both models are backed by a standard 10-year warranty. Y 7 I SPR-3000rn and SPR-4000m sunpowercorp.com 1-800-SUNPOWER I i I 3000m and 4000m INVERTERS S U N ROW E R' EXCEPTIONAL RELIABILITY AND PERFORMANCE Electrical Data SPRm Efficiency Curves 100 SPR-3000m SPR-4000m 95I-250-Vdc— AC Power 3000 W 3500 W @ 208 V/ 90 310 Vdc 4000 W @ 240 V —� � t", 480 Vdc 1 -----._ ____-- ------ d 85 AC Maximum Output Current 15A,13A 17A ramu 80 j ( (@ 208V,240V) 75 1 I 183-229 V @ 208 VAC 183-229 V @ 208 VAC I 70 — ACNominalVoltage/Range 211-264 V @ 240 VAC 211-264 V @ 240 VAC 0% 10% 20% 30% 40% 50% 60% 70% 80% 90�% --- %of Rated Output Power 60 Hz/59.3 Hz- 60 Hz/59.3 Hz- j AC Frequency/Range 60.5 Hz 60.5 Hz -- — — - --- ...-------- Mechanical Data ---- ----- I Power Factor 1 1 Shipping Dimensions W x H x D(inches) 23.5"x 1 a.5"x 16.0° —— -- — _ j — Unit Dimensions W x H x D(inches) ns"x 13.8"x 9.3" Peak Inverter Efficiency 96.5% 96.8% 1 Inve,,t r We —8 lbs Inverter Weight ea Ibs I 95. %@ 20 V 95. %@ 20 V Shipping Weight 94 Ibs i CEC Weighted Efficiency 0 9 5 8 95. %@ 208 V 9 . %@ 208 V -- ----- - ---- ff Forced Air/Sealed E i ----'----- Cooling I Electronics Enclosure , j Recommended Array Input 3750 W 4375 W @ 208 V t ` Power(DC @ STC) 5000 W @ 240 V -Enclosure---_--- --- -- --NEMA 31Z ---------- t l — Mounting Wall Mount Bracket Standard 200-500 V @ 208V 250-600 V @ 208 VAC DC Input Voltage Range f 200-500 V @ 240V 250-600 V @ 240 VAC i i Ambient Temperature Range -13 to+113 T i 175-400 V @ 208 VAC 220-480 V @ 208 VAC Warranty and Certifications Peak Power Tracking Voltage I 200-400 V @ 240 VAC 250-480 V @ 240 VAC r---------------- �------- -'-"—--- I Warranty 10 year limited warranty i hance:lEEE-929,IEEE-1547,UL1741-2005, Certifications Compliance:DC Max.Input Current P l UL 1998,FCC Part 15 A&B — 1 I DC Voltage Ripple <5% 1 -- _, 1170 9]3 I i . No.of Fused String Inputs 4 Power Consumption: <7 W/0 t W j Standby/Nighttime I Fused DC Disconnect Standard;Complies w NEC Standards Configurable in the field with integrated grounding kit: ), I Electrical Grounding SunPower-Solar Panels:DC circuit positively grounded Serengeti-Solar Panels:DC circuit negatively grounded _ I � 6 ; About SunPower I Founded in 1985,SunPower Corp. (Nasdaq:SPWRA,SPWRB) designs, manufactures and delivers the planet's most powerful solar technology broadly available today. Residential, business,government and utility customers rely on the company's experience and proven results to maximize return on investment. 1 t , SUNPOWER and the SUNPOWER logo are trademarks or registered trademarks of SunPower Corporation. s u n powerco rp.co m 1 @ March 2010 SunPower Corporation.All rights reserved.Specifications included in this datasheet are subject to change without notice. Document#001-16966,Rev•A • • • i S U N POWE R" STRING INVERTERS I BENEFITS Reliable and Robust Design Proven track record for durability and longevity l. 4 Effective Power Range: 3 , Enables most systems to use a single , inverter rather than multiple units Commercial Use Flexible AC voltage output and scalable building blocks create an easy solution for commercial applications High Efficiency , Weighted CEC efficiency of'at. least,95.5% and,peak efficiency of at least 96.5% Reduced Installation Cost. Integrated DC disconnect with fuses I lowers material costs and labor requirements SunPower SPR-5000m, -6000m, -7000m and -8000m Attractive Aesthetics inverters offer superior reliability and performance and I Integrated disconnect eliminates can be easily integrated into residential or commercial need for visible conduits to inverter installations. All models are backed by a 10-year warranty. 77- ,t ;I ' n ' 1 ' i SPR-5000m -6000m -7000m and-8000m. sunpowercorp.com ' 1-800-SUNPOWER . 1 •R 111 6111 111 and : 111 S U N ROW E R- STRING INVERTERS Electrical Data _- - -__ 1 � Mechanical Data ( i j rString Inverters SPR-5000m SPR-6000m SPR-7000m SPR-8000m SPR-5000m,SPR•6000m, AC Nominal Power j 7680 W @ 240 V SPR-7000m and SPR-8000m 5000 W 6000 W 7000 W 8000 W@ 277 V I I AC Max Output Current(@ 208V, 24 A,21A, 18A 29A,25A,22A134A,29A,25A N/A,32A,29A Shipping Dimensions 240V,277V): W x H x D(inches) [23.5"x 31.0"x 16.0" AC Nominal 183-229 V @ 208 V 183-229 V @ 208 V 183-229 V @ 208 V N/A @ 208 V Voltage/Range 211-264 V @ 240 V 211-264 V @ 240 V 211-264 V @ 240 V 211-264 V @ 240 V i 244-305V@277V I244-305V@277V 244-305V@277V 244-305 V @ 277 V Unit Dimensions -I-.- -- W x H x D(inches) 18.4"x 24.1"x 9.51, ! AC Freq/Range 60 Hz/59.3 Hz- 60 Hz/59.3 Hz- 60 Hz/59.3 Hz- 60 Hz/59.3 Hz- _-- j 60.5 Hz 60.5 Hz 60.5 Hz 1 60.5 Hz Power Factor 141 Ibs for SPR-5000m, I 0.99 0.99 0.99 0.99 (Nominal) Inverter Weight 6000m and-7000m/ - - `-+ -_-- 148 Ibs for SPR-8000m I Peak Inverter 96.8% 97.0% 97.1% � 96.5% , Efficiency --�---- I 95.5%@ 208 V 95.5%@ 208 V 95.5%@ 208 V N/A @ 208 V 148 Ibs for SPR-5000m, CEC Weighted 95.5%@ 240 V 95.5%@ 240 V 96.0%@ 240 V 96.0%@ 240 V Shipping Weight -6000m and-7000m i4 Efficiency 95.5%@ 277 V 96.0%@ 277 V 96.0%@ 277 V 96.0%@ 277 V- /15216sforSPR-8000m Recommended Maximum PV Power 6250 W 7500 W 8750 W 10000 W Forced Air/Sealed (Module @ STC) -- Cooling Electronics Enclosure j DC Input 1250-600 V 250-600 V 250-600 V 300-600 V (+ i - - Voltage Range -- E ndosure -, NEMA 31Z - I Peak Power 250-480 V 250-480 V 250-480 V 300-480 V Mounting I Wall Mount Tracking Voltage L oung - Bracket Standard �- DC Max. 21 A 25A 30A 30A--- -- --- f Input Current F p - _i Ambient I-13 to+113°F 1 Temperature Range i DC Voltage Ripple 4% 4% 4% ------ 4/ - - No.of Fused 4 1 4 4 14 I String Inputs I 1 Power Consumption:-', -- ---� ---^--- ~ ' <7W/0.1 W Warranty and Certifications Operation/Nighttime I Topology Low frequency transformer I Warranty 10 year limited warranty Fused DC Disconnect Standard;Complies with NEC Standards - Compliance:IEEE-929, E r Configurable in the field with integrated grounding kit: Certifications IEEE-1547,UL 1741, � Electrical Grounding SunPower-Solar Panels:DC circuit positively grounded UL 1998,FCC - part 15 A&B Serengeti'^+Solar Panels:DC circuit negatively grounded - ---- --SPRm EFFICIENCY CURVES -- - -----____-___-_- 18.4" 9.5" I 100 ,j { 95 350-Vde- I 90 310 Vdt- ' y 480 Vd< t= 85 24. 1 y I 80 75 i J 70 tl 0% 10% 20% 30% 40% 50% 601/ 70% 80% 90% 100% j %of rated output power About SunPower If ' k I j Founded in-1985, SunPower Corp. (Nasdaq: SPWRA-SPWRB designs, manufactures and delivers the planet's most powerful solo p. ( q: ) 9 P P I � 1 technology. Residential, business, government and utility customers rely on the company's experience and proven results to maximize return on investment. ISUNPOWER and the SUNPOWER logo are trademarks or registered trademarks of SunPower Corporation. SUI'1pOW@rCOrp.cOm i ®July 2010 SunPower Corporation.All rights reserved.Specifications Included in this dotasheel are subject to change without notice. Document#001-16967 RevB #1