Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
37037-Z
��o�s�FF�l,�coGy Town of Southold Annex 4/30/2012 P.O.Box 1179 � 54375 Main Road oy �Y Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 35569 Date: 4/30/2012 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 965 Leeward Dr, Southold, SCTM#: 473889 Sec/Block/Lot: 79.-7-24 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 2/24/2012 pursuant to which Building Permit No. 37037 dated 3/5/2012 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted electric Solar Panel system on an existing one family dwelling as applied for. The certificate is issued to Rumpler IV,John (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 37037 4/4/12 PLUMBERS CERTIFICATION DATED Aut rized Signature TOWN OF SOUTHOLD �� ay BUILDING DEPARTMENT z TOWN CLERK'S OFFICE o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 37037 Date: 3/5/2012 Permission is hereby granted to: Rumpler IV, John 965 Leeward Dr Southold, NY 11971 To: install a roof mounted electric Solar Panel system as applied for At premises located at: 965 Leeward Dr, Southold SCTM # 473889 Sec/Block/Lot# 79.-7-24 Pursuant to application dated 2/24/2012 and approved by the Building Inspector. To expire on 9/4/2013. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $200.00 CO -ADDITION TO DWELLING $50.00 Total: $250.00 Building Inspector Form No.6 TOWN OF SOUTHOLD. BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. 'Sworn statement from plumber certifying that the solder used in system contains less than 2110 of 1% lead. . 5. Commercial building,industrial building, multiple residences and similar buildings and installations,a certificate of Code Compliance'from architect or engineer responsible for.the building.. .6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing"land uses: L . Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2- A properly spmpleted application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling.$50.00,Additions to dwelling$50.00, Alterations to dwelling$50.00, Swimming pool $'50.00, Accessory building$50.00,Additions to accessory building$50.00,Businesses $50.00_ 2. Certificate of Occupancy on Pre-.existing Building- $100.00 3. Copy of Certificate of.Occupancy-$_25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy -Residential $1 5.00, Commercial $15.00 Date. Y(.1,�1� Z:j,2Ol Z- New Construction: Old or Pre-existing Building: ' ✓ (check one) Location of Property: (p L-e eW a✓c� t�/C-'_ c�Oe,c-�-h p Lcl House No. (� Street Hamlet Owner or Owners of Property: _ _Jd�In Suffolk County Tax Map No 1000, Section Q Block —] Lot 2— Subdivision n Filed Map. , ,Lot: Permit No. 3 ./ Date of Permit. 3 ` - 17. Applicant: G V-e�`J"1 tC Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $. 50. '— licant Signature O��pF SO(/T�ol Town Hall Annex ~ Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Q roger.richert(a).town.southold.ny.us Southold,NY 11971-0959 OUNTY,Nc� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: John Rumpler IV Address: 965 Leeward Drive City: Southold St: NY Zip: 11971 Building Permit#: 37037 Section: 79 Block: 7 Lot: 24 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: License No: SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling.Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke.Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: roof mounted photovoltaic system To include, 36 Sun Power panels 1 Sun Power 8000 inverter. (8280 watts) Notes: Inspector Signature: Date: April 4 2012 81-Cert Electrical Compliance Form.xls OF SOUry�� , o�ycoy,� TOWN OF SOUTHOLD BUILDING- DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. • [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING/STRAPPING [FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: DATE l �--- INSPECTOR OF SOUly�lo `- TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) REMARKS: DATE P �v INSPECTOR Pacifico Engineering PC Engineering Consulting PO Box 1448 � ` ; Ph: 631-988-0000 Sayville, NY 11782 UJ Fax: 631-382-8236 www.pacificoengineering.com engineer@pacificoengineering.com March 26, 2012 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for John Rumpler IV 965 Leeward Drive Southold, NY 11971 I have reviewed the solar energy system installation at the subject address. The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets the requirements of the 2010 NYS Building Code, and ASCE7-05. To my best belief and knowledge, the work in this document is accurate, conforms with the governing codes applicable at the time of submission, conforms with reasonable standards of practice,with the view to the safeguarding of life, health, property and public welfare Regards, Ralph Pacifico, PE Professional Engineer ON PAC/ Y nN PAC/coW2012 066tiCX �' T.� HOLD Rai ph'Pa ificomUi I Engineer . NY 066182`/NJ-246E04744306 f! FIELD ZSPECT QN REPORT DATE COMMENTS UT�J � tid FOUNDATION(1ST) 7 rr .ororrrwrgrwre.wrooa _ . FOUNDATION(ZND) ►� IQ 0 0 . M ROUGH FRAMING& H PLUMBING 7p . . cn IN$UL•ATION PER N.Y. STATE ENERGY CODE r r FINAL ADDITIONAL COMMENTS O LA— CA . '' II rn a TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. 37037 Check Septic Form N.Y.S.D.E.C. Trustees r Flood Permit Examined 20 Storm-Water Assessment Form Contact: G`ten( f UL L Approved U 20 Mail to: 1-1 ZS CoueiN "3q�r Disapproved a/c SOu&'IaWw(mi 0'4 l l4(o S Phone: �3l' 71 I' 515 Z Expiration q V ,20� Building Inspector APPLICATION FOR BUILDING PERMIT Date 2 3 , 20 12- INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale. Fee,according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws, Ordinances or Regulations,for the construction of buildings, additions,or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. C vee�- L&gLe-- (Signature of applicant or name,if a corporation) 3 � hann r`-f'1 2cQ � . ►�N Vact (Mailing address of ap licant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Con4y-:�!,e_+� Name of owner of premises b�n Q.LLryJ P1Cr (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name a d title of corporate officer) Builders License No. L4 O 22-7- 1 Plumbers License No. Electricians License No. 4313 5�i - M E Other Trade's License No. 1. Location of land on which proposed work will be done: Sot,4 ko Ld q(05 Leew.%► bvtve— House'Number Street Hamlet County Tax Map No. 1000 Section -7 Block � Lot 2-4 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premttnr4ltf s and intendeg use and occupancy of proposed construction: a. Existing use and occupancy m 1 ( dt ye(f cnc'j b. Intended use and occupancy St a[t° ZrVi i t y C�r,J e((t✓�q 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work O(f Mcu-n-k-,4 Sow c Sf,S scription) 4. Estimated Cost q 2, Lt 23 Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase g .q. 1 l Name of Former Owner S r fi la L. - tLtbe L l y i n!q Tru S-I- 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO f Will excess fill be removed from premises? YES NO John Qum e� ►� 0lfo5 l�•-d. br 14.Names of Owner of remises Pl Address Sou�ino�d Phone No. 1o3t-3z�-z``t Name of Architect Vacri^a �r cn�+-arc pc Address�'an �igOvr` 7s77. Phone No b31 'a 8 I?-ODD 0 Name of Contractor C_ r�nLgjtc. LCC- Address M Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO ✓ * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO ✓ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16.Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO- * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF S�-t-Oi N-e St►-n being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the (Contractor,Agent, Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this 1� day of 201 Z 61t'c� a-0 Not Public BARBARAA,CASCIOTTA Signature of Applicant Notary Public,State of New Yolk_,. No.01-CA4894969 Ouslified In Suffolk Co Cotwission Expires May 11.unt� 0 1-S 2- Town Hall Annexiff Telephone(631)765-1802 54375 Main Road ,,aaxx g QQ22 P.O.sox 1179 .; 0 roner.richert(Q IOWf S 6uT 5o&ny us Southold,NY 1197I-0959 Q BUILDING DEPARTMENT i TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Date: Z -23- 12_ Company Name: near, L0q cc LL Name: P-obce+ Ic a (a License No.: 43 g 5 is- ry is Address: 4;2S 00u# I?A3gA 0aVP1aknn lIR(Ok Phone No.: JOBSITE INFORMATION: (*Indicates required information) *Name: J ok 1-1 QVurn l>°v l V *Address: q(o S -e .I- -Oa WA I 1C %LA-I n0 0 *Cross Street: *.Phone No.: 2-1a-1 Permit No.: -3-103-7 Tax-Map District: - 1000 . Section: Block: -7 Lot: J- *BRIEF DESCRIPTION OF WORK(Please Print Clearly) Moue4ej e (,3�)Su.nRbWer 23Obot-� vynodu.Les 8a 90 t�+4s g`j�e CI) SunP-k S.pr Toclovn tr,yex�k--✓ (Please Circle Alt That Apply) *Is job ready for inspection: YES/ NO. Rough In Final y *Do-you need a Temp Certificate: YES! NO Temp Information(if needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead ' Additional Information: PAYMENT DUE WITH APPLICATION .82=Request for Inspection Form 1 I Town of Southold z Erosion, Sedimentation & Storm-Water Run-off ASSESSMENT FORM PROPERTY LOCATION: S.C.T.M.#: THE FOLLOWING ACTIONS MAY REQUIRE THE SUBMISSION OF A 01 low -1!s STORM-WATER,GRADING,DRAINAGE AND EROSION CONTROL PLAN rs� section- o --Tot—� CERTIFIED BY A DESIGN PROFESSIONAL IN THE STATE OF NEW YORK. i i SCOPE OF WORK - PROPOSED CONSTRUCTION DIEM# / WORKASSESSMENT Yes No a. What is the Total Area of the Project Parcels? I Will this Project Retain All Storm-Wateir Run-Off (include Total Area of all Parcels located within Generated by a Two(2')Inch Rainfall on Site? the Scope of Work for Proposed Construction) (S.F. Aces) (This item will include all run-off created by site V ❑ i ! b. What is the Total Area of Land Clearing clearing and/or construction activities as well as all and/or Ground Disturbance for the proposed Site Improvements and the permanent creation of construction activity? impervious surfaces.) (S.F.!Acres) PROVIDE BRIEF PROJECT DESCRIPTION (Provide Additional Pages ea Needed) 2 Does the Site Plan and/or Survey Show All Proposed Drainage ❑ i Drainage Structures Indicating Size&Location?This P� Sri��� Item p shall include allProposed Grade Changes and Iwo. m our Slopes ControllingSurface Water Flaw. ( 3 Does the Site Plan and/or Survey describe the erosion ✓❑ and sediment Control practices that will be used to control site erosion and storm water discharges. This Item must be maintained throughout the Entire Construction Period. 4 Will this Project Require any Land Filling,Grading or i Excavation where there is a change to the Natural Existing Grade Involving more than 200 Cubic Yards of Material within any Parcel? 5 Will this Application Require Land Disturbing Activities Encompassing an Area in Excess of Five Thousand El (5,000 S.F.)Square Feet of Ground Surface? 6 Is there a Natural Water Course Running through the Site? Is this Project within the Trustees jurisdiction ❑ General DEC SWPPP Requirements: orwithin One Hundred(100')feet of a Wetland or Submission of a SWPPP is required for all Construction activities involving soil Beach? disturbances of one(1)or more acres; including disturbances of less than one acre that 7 Will there be Site preparation on Existing Grade Slopes ❑ are part of a larger common plan that will ultimately disturb one or more acres of land; which Exceed Fifteen(15)feet of Vertical Rise to Including Construction activities involving soil disturbances of less than one(i)acre where One Hundred(100')of Horizontal Distance? the DEC has determined that a SPDES permit Is required for storm water discharges. (SWPPP's Shall most the Minimum Requirements of the SPDES General Permit 8 Will Driveways,Parking Areas or other Impervious ❑ r for Storm Water Discharges from Construction activity-Permit No.G13-010-001.) Surfaces be Sloped to Direct Storm-Water Run-Off 1.The SWPPP shall be prepared prior to the submittal of the NOI.The NOI shall be into and/or in the direction of a Town tight-of-way? submitted to the Department prior to the commencement of construction activity. 2.The SWPPP shall describe the erosion and sediment control practices and where 9 Will this Protect Require the Placement of Material, F-1 — required,post-construction storm water management practices that will be used and/or Removal of Vegetation and/or the Construction of any constructed to reduce the pollutants In storm water discharges and to assure Item Within the Town Right-of-Way or Road Shoulder compliance with the terms and conditions of this permit.In addition,the SWPPP shall Area?(ibis Item vAl NOTlndude the Installation of Driveway Aprorm) identify potential sources of pollution which may reasonably be expected to affect the quality of storm water discharges. NOTE: If Any Answer to Questions One through Nine Is Answered with a Check Mark 3.All SWPPPs that require the post-construction storm water management practice In a Box and the construction site disturbance Is between 5,000 S.F.&1 Acre in area, component shall be prepared by a qualified Design Professional Ucensed In New York a Stonn-Water,Grading,orainage&Erosion Control Plan is Required by the Town of that Is knowledgeable In the principles and practices of Storm Water Management, Southold and Must be Submitted for Review Prior to Issuance of Any Building Permit. (NOTE: A Check Mark 14)and/or Answer for each Question Is Required for a Complete Application) STATE OF NEW YORK, S uU COUNTYOF...........................................SS That I,............... W�rn.................................................being duty sworn,deposes and says that he/she is the applicant for Permit, (Name of inkfrvldual signing Document) Andthat he/she is the .......................................... ....................... ....... (owner,�Coritiactor,Agent,Corporate Officer,etc.j� Owner and/or representative of the Owner or Ovmers,and is duly authorized to perform or have petformed the said work and to make acid file this application;that all statements contained in this application are true to the best of his knowledge and belief;and that the work mill be performed in the manner set fortis in the application filed herewith. Srtom to before me this; ................... ... ...... day j1�(.L--"rq......... ,2012— Notary Public: ....... / 101`T ..... ........................ A� X A (Signature of Applicant)' FORM - 06/10 No.01-CA4894969 Qualified in Suffolk Count Commission Expires May I I. y rs O��pF SO�Tyol Town Hall Annex ~ Telephone(631)765-1802 54375 Main Road 41 Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 • �O COUNT`I,Nc� BUILDING DEPARTMENT TOWN OF SOUTHOLD April 5, 2012 John Rumpler IV 965 Leeward Dr Southold, NY 11971 TO WHOM IT MAY CONCERN: The Following Items Are Needed To Complete Your Certificate of Occupancy: Note: Please have an Architect or Engineer certify that the panels were installed according to New York State code. Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. (contact your electrician) A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. BUILDING PERMIT : 37037 — Solar Panels is f - R ENL0GIC ENERGY April 25, 2012 The Town of Southold Building Department 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Re: Building Permit No. 37037 John Rumpler IV 965 Leeward Drive, Southold To the Building Inspector: Enclosed please find the Engineer's Certification Letter for John Rumpler's solar electric system, which we installed at 965 Leeward Drive, Southold. Please arrange to send him the Certificate of Occupancy and close out the building permit. Please let me know if you have any questions about the installation. Sincerely, /'))r fiG,-, &4UtaXC-1- Barbara Casciotta Account Manager GreenLogic LLC 631-771-5152 ext. 117 GREENLOGIC, LLC • www.GreenLogic.com Tel: 877.771.4330 Fax: 877.771.4320 SOUTHAMPTON/CORPORATE: CUTCHOGUE: MANORVILLE: NEW YORK CITY: ROSLYN HEIGHTS: 425 County Rd.39A 1070 Depot Lane 40 Woodland Avenue 241 6th Avenue #36 200 S. Service Rd.,#108 Southampton, NY 11968 Cutchogue, NY 11935 Manorville, NY 11949 New York, NY 10014 Rosyln Heights, NY 11577 %,' \� / �' \\ / �, \\�/ :%� t \\/r•• ram' •.\K,// Fitz l .. \�. �� � CJP + -`r ;h -.. '•;:-- 'r� �,S v��j'. ..!"; �'+�` "'1 ., ?` •• ':c �11r \iU°i`�'� �fi :.mil-.r ti%� f�'� jy':. r J' Office DATE ISSUED: 12/10/2007 No. : - < ' MasterSUFFOLK COUNTY Electriciani r This is tocertify that1 ' doing business GREENLOGIC LLCwith and subject to the provisions of applicable laws,rules and regulations of having given satisfactory evidence of competency,is hereby licensed as MASTER ELECTRICIAN in accordance j the l Countyof • of • 4 ^; Additional VALIDNOT WITHOUT DEPARTMENTAL SEAL { >. r` CONSUMER •cl 11) { Director A. C ��. ,n7 .. =w•... 4f'• � �, s ry •1!'�e SP'. ..� �f�' i .:`Cr^ ,r':. ' .- a\kJ '� "-Al as ` r�) �;� bA•. 4 F. ` 4 � . gp' a ° �� �1Si,,��; °/i \\ �✓ � /� \\-; Gi �, //\\ •�ii . � /�\\: ''�� � 11•\\:. .�•, �: -!/ \\'':. �,��-"�� I!\\ '-�4!�,�; �•// \\ • lip�:JF Pacifico Engineering PC =;, Engineering Consulting PO Box 1448 -:r i c Ph: 631-988-0000 Sayville, NY 11782 - I�i ,i ! Fax: 631-382-8236 www.pacificoengineering.com engineer@pacificoengineering.com February 17, 2012 Town of Southold APPROVED AS NOTED Building Department 54375 Route 25, P.O. Box 1179 DATE B.P, # 3 Southold, NY 11971 FEE:�"°� BY Subject: Solar Energy Installation for NOTIFY BUILDING DE ARTMEti IT AT' John Rumpler IV 765-1802 8 AM TO 4 PM FOF, 965 Leeward Drive FOLLOWING INSPECTIONS- Southold, NY 11971 y �` `' 1. FOUNDATION - TWD RF OOURED ® � ,ra='I �;;`y .. �L : ? FOR POURED CONCR .. i E I F 2. ROUGH•FRAMING PLJMENG, STRAPPING. ELECTRICAL CAULKA " I� 3. INSULATION �f©9m�1��� � 4. FINAL • CONSTRUCT,:-I, n5 MUST BE C`MPLETc:: ;R C C� . +ic,, � I� .ap ?•��;' ALL CONSTRUt;T!UN SHgL REOLPREMEN76 OF YORK STATE "JOT RE, ;ir!', ic:• _ c. DESIGN OR CONSTRUCTION 6.PPf7, I have reviewed the roofing structure at the subject address. The structure can support the additional weight of the roof mounted system.The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2010 NYS Building Code, and ASCE7-05 when installed in accordance with the manufacturer's instructions. Roof Section A mean roof height 13 ft pitch 4 3/4 in/12 ELECTRICAL roof rafter 2x6 with 2x4 purlins INSPECTION ION REQUIP77-1. rafter spacing 16 in OC Reflected roof rafter span 10.2 ft Table R802.5.1(1)max 13.3 ft The climactic and load information is below: CLIMACTIC AND Ground Wind Live load, GEOGRAPHIC DESIGN Category Snow Load, Point Speed,3 pnet30 per Pullout Fastener type g ry sec gust, ASCE 7, CRITERIA Pg mph psf load,lb Roof Section A C 20 120 57 1167 5/16"dia screw, 4-1/2" length, 2 per \@N PAC/P 0p� aj P O j + ; Ralph Pacifico, PE ('n w I w Professional Engineer ?/ ,o 066182 �1 RaiPh:a fico P essWd,1,E -ineer NY 0651&2 ¢ E04744306 LOG IC` ELIMINATING THE COST OF ENERGY i Pacifico Engineering PC PO Box 1448,Sayville,NY 11782 531.988.00M www.paciflocangineedng.com Ralph Pacifica,Professional Engineer *Always double check measurements NY Lic066182 NJ Lic 24GE04744300 GreenLogic, LLC—Approved 8.28kW Layout 36 Sunpower 230w Panel Dimension = 61.39"x31.42" --NEvv Array Length = 502.72" �i' 0 Y UniRac Sunframe Array Height = 188.67" %���QN PACiF�CG \ John Rumpler Azimuth = 176 A - o 965 Leeward Drive Pitch = 22° Surface Dimensions =585 x239 J/( Q-i' � , Southold, NY Scale 3/16" = 1.0' Magic#= 62.14" �j X cc, 1 r_ ' fL ISSUES 1 SPECIAL INSTRUCTIONS 0 PROJECT COMPONENT COUNT 5. Sunpower 230w ` s- A) Attachment type and count: 61$Zl • Attachment Point OFESSIG� B) Rail type and count: UniRac Sunframe o UniRac Sunframe ���_;1'' 2x6"Douglas Fir Rafters 16"On Ralph Pacifico Professional Engineer Center NYS Lilt 066182 NJ Lice 249E04744300 Layout Created By: MVP Date: 11-11-11 G R - -NLOGIC' These 8 rafters will be sistered,while all F_ others will have purlins ELIMINATING THE COST OF ENERGY L k I AN IT A I: ` it i N' I � I i 1 IKITA V 1\ A I F7 F 1-7-1-IF7-1 1 1 [111771 1 Pacifica Engineering PC PO Box 1448,Sayvifle,NY 11782 631-988-0000 www.pacificcenginsering.com Ralph Pactfico,Professional Engineer *Always double check measurements NY Uc 066182 NJ Uc 24GE04744300 GreenLogic, LLC —Approved 8.28kW Panel Dimension = 61.39"x3l.42" --- Layout 38 Sunpower 230w NEW UniRac Sunframe Array Length 502.72" PACi 0 John Rumpler Azimuth = 1760 Array Height 188.67" 965 Leeward Drive Pitch = 220 Surface Dimensions =585"x239" co Southold, NY Scale 3/16" Magic# = 62.14" 1.0' W I ISSUES/SPECIAL INSTRUCTIONS PROJECT COMPONENT COUNT A) Attachment type and count: 39 Standoffs Sunpower230w 86 • Attachment Point 13) Rail type and count: UniRac Sunframe UniRac Sunframe O2x6"Douglas Fir Rafters 16"On Ralph Pacifico Professional Engineer Center NYS Lic#C66182 NJ Uc#249EC4744300 Layout Created By: MVP Date: 11-11-11 [,.I LOG IC ELIMINATING THE COST OF ENERGY V VV AA Pacifico Engineering PC 130 Box 1448,Sayville.NY 11762 631-988-0000 www.pacificc"ineedng.com Ralph Pacillco, 4x9 on SPR8000m *Always double check measurements NY Uc 066182 NJ LicProfe5slonal 24G E04744300Engineer GreenLogic, LLC —Approved 8.28kW Panel Dimension = 61.39"x3l.42" — Layout 36 Sunpower 230w Array Length 502.72" NEW UniRac Sunframe Array Height 188.67" �,Vk PAC 0 John Rumpler Azimuth = 176* 11 965 Leeward Drive Pitch = 22' Surface Dimensions =585"x239 co Southold, NY Scale 3/16" = 1.0' Magic#= 62.14" W ISSUES I SPECIAL INSTRUCTIONS > PROJECT COMPONENT COUNT Sunpower230w A) Attachment type and count: 0 Attachment Point 0661 B2 B) Rail type and count: UniRac Sunframe oUniRac Sunframe oppsslo _i 2x6"Douglas Fir Rafters 16"On Ralph Pacifico Professional Engineer Center NYS Lich 0ffi182NJijc#249E04744300 Layout Created By: MVP Date: 11-11-11 !--_: !\;LOGIC" i= ELIMINATING THE COST Of ENERGY • 2x4 Douglas Fir Purlins to be added from top plate of bearing wall to roof rafter at 16"on center. • 8 Rafters to the west of chimney will be sistered with 2x6 Douglas Fir full span. 45.0° i Framing; 2x8 Douglas Fir ridge. 2x6 Douglas Fir rafters, spanning 19'11", spaced 16"on , nter. x6 Douglas Fir ceiling joists spaced Won center. 2x4 Douglas Fir exterior wall. 1/" Plywood sheathing. Pacifico Engineering PC PO box 1440,Sayville;NY 11782 631-98B-0000 mmpacificcengineering.wm *Always double check measurements NYLIc0661 2 NJLec 24GIE04744300 GreenLogic, LLC—Approved 8.28kW Panel Dimension = 61.39 x31.42 Layout 36 Sunpower 230w Array Length = 502.72" F UniRac Sunframe C John Rumpler Azimuth = 176' Array Height = 188.67" •A�v X�\ pAcIF��, Surface Dimensions =585"x239" f�� O 965 Leeward Drive Pitch = 22 Southold, NY Scale 3/16" = 1.0' Magic# = 62.14" ISSUES/SPECIAL INSTRUCTIONS I _z PROJECT COMPONENT COUNT i �i r • . C? Sunpower 230w A)Attachment type and count; • Attachment Point 066� �Q B) Rail type and count: UniRac Sunframe — UniRac Sunframe �' PRO FESS\° A 2x6"Douglas Fir Rafters 16"On Ralph Pacifico Professional Engineer Center NYS Licf106612 NJ Lisp 249E04744300 Layout Created By: MVP Date: 11-11-11 `,E— .aL®CIC` ELIMINATING THE COST OF ENERGY Material List t(�y Rail Material List tC UniRac 4"Drk Standoffs 39 5/16"AY SS Lag Bolts 78 5/16"Stainless Steel Washers 78 ,•�vY `P C Ffr��`� CO r w lopROFESS\O� *Always double check measurements. GreenLogic, LLC—Approved 8.28 kW Sunpower 230w Layout 36 Sunpower 230w Panel Dimension = 61.39"x31.42" UniRac Sunframe Array Length = • Attachment Point John Rumpler Azimuth = 2760 Array Height = o UniRac Sunframe 965 Leeward 16" ard Drive Pitch = 22' Surface Dimensions = Southold, NY Scale 3/16" = 1.0' Magic#= Douglas Fir Rafter On Center PROJECT COMPONENT COUNT ISSUES/SPECIAL INSTRUCTIONS A) Attachment type and count: B) Rail type and count: UniRac Sunframe Layout Created By: MVP Date: 11-11-11 { Lpf E�ra•0 Lot 33 411 ' I `4Vtj is p• rt �,�'�'�� O ,C) O I 1 zz. 29_d1 I 4jL f tepf�� TO 7HSUe�ALTERATION OR ADDITION 17ON or 00 , -:Ar e, w v nk O EDUCAi ON LAW: THE NIEW ONX STATE �� "� o '� I y ^ I �`` COPIES OF THIS SURVEY 1dAP NOT G R+ 4•" _ , C THE LAND SURVEYOR'S INKED AEARIN 1• �� Q� SEAL OR L' n �1- EMLOSSED SEAL SHALL IIOT Qf Sr 1': c♦iJ`� i0 EE A VALID TRUE COPY. CONSIDERED GUARANTEES INDICATED HEREON SHALL RUN IS ONLY TO THE PE[SON FOR WHOM THE Sll.V?y TITLECOMPANY.D 0"HIS E.hALF f0 III — n' cI �` .r,TO/��2 UNDING INSIITLTG;-,USTE'HAL A41hCt AND R-�ZZ7 7QQO f• W� 10 THE ASSIGruL3 OF THE LRfON,AND LEF.ZING JNSTJ. :I `� ..✓` �97 2 .7Z• TO IAODRIOARATEES ARE NOT TRANSFLRAw IEE4=3/,9 3��� OWNERS. F`"L uslnurloxs oR ttusL�E,� r5' ol 0 t" PREVISIONS YOUNG & YOUNG t1CT. 19,1972 400 OSTRANDER AVENUE, RIVERHEAD, NEW YORK ALDEN W. YOUNG HOWARD W.YOUR` F. o� PROFESSIONAL ENGINEER AND LAND SURVEYOR ��f� j• LAND SURVEYOR, N.Y.S. LIC. NO, 12Ei43 Y16F O. 4589: SURVEY FOR: r• Q so, •o_ �' RICHARID E.ODDON & EILEEN OD N o�P�D v''• Oe. I LOT 33, LEEWARD ACRES AT BAY I* `� NOTE- o=MONUMENT SUBD/V/S/ONMAPF/LED/NTHEOFF/CE !t® I OFTH4,1971 CLERK ILEN 5599.TYON , AT BAY V I E W 'UA Mo 1�TK : UST 0. JUNE4,/97/AS FtLENO.5599. �' TOWN OF ECUR CO.`t�.s T . SOUTHOLD '::;.. �HD \\ SUFFOLK CO., N.Y. S SCALE: III = 40' DATE: JULY 17,1972 No'72 -513