Loading...
HomeMy WebLinkAbout36482-Z r'�SFF l Town of Southold Annex 11/10/2011 c�Gy 54375 Main Road z Southold,New York 11971 w ^ CERTIFICATE OF OCCUPANCY No: 35285 Date: ' 11/10/2011 THIS CERTIFIES that the building RESIDENTIAL.ALTERATION Location of Property: 645 Southern Cross Rd, Cutchogue, SCTM#: 473889 Sec/Block/Lot: 110.-5-27 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 6/3/2011 pursuant to which Building Permit No. 36482 dated 6/15/2011 .was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Alterations to a Single Family Dwelling; Resurface Deck, Outdoor Shower,Replace Windows, and Relocate Overhead Electric Service as applied for. The certificate is issued to Bohan,Peter&Bohan, Julie (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 36482 11/9/11 PLUMBERS CERTIFICATION DATED , h rize Signak re F of L TOWN OF SOUTHOLD �� oy BUILDING DEPARTMENT y z TOWN CLERK'S OFFICE "o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 36482 Date: 6/15/2011 Permission is hereby granted to: Bohan, Peter& Julie 11 Cambridge Ave Stewart Manor, NY 11530 To: Alterations to a Single Family Dwelling; Resurface Deck, Outdoor Shower& Replace Windows, as applied for. At premises located at: 645 Southern Cross Rd, Cutchogue SCTM # 473889 Sec/Block/Lot# 110.-5-27 Pursuant to application dated 6/3/2011 and approved by the Building Inspector. To expire on 12/14/2012. Fees: CO -ALTERATION TO DWELLING $50.00 SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $269.60 Total: $319.60 Building Inspector Form No.6 TOWN OF SOUTHOLD. BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. . 5. Commercial building,industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance'from architect or engineer responsible for the building. .6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00, Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool $50.00, Accessory building$50.00,Additions to accessory building$50.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-.existing Building- $100.00 3. Copy of Certificate of.Occupancy-$:25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy -Residential $15.00, Commercial $15.00 Date. New Construction: ° Old or Pre-existing Building: ' (check one) Location of Property: House No. Street Hamlet Owner or Owners of Property: 4L p , Suffolk County Tax Map No 1000, Section_ %/C' Block Lot o2 Subdivision Filed Map. Lot: Permit No. 3(- Y U Date of Permit. - /s - t! Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: / Request for: Temporary Certificate Final Certificate: ✓ (c eck jone) Fee Submitted: $ Applicant Ynature pF SO!/ryolo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 en �o roger.riche rt('cD-town.southo Id.ny.us Southold,NY 1 197 1-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Bohan Address: 645 Southern Cross Rd City: Cutchogue St: NY Zip: 11935 Building Permit* 36482 Section: Block: Lot: WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Rocky Point Electric License No: 32644-me SITE DETAILS Office Use Only Residential X Indoor Basement Service Only X Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph 200a Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200a A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect 200a Switches Twist Lock Exit Fixtures 9 TVSS Other Equipment: Relocate 200a overhead service to side of building (did not change main panel) Notes: Inspector Signature: Date: Nov 9 2011 81-Cert Electrical Compliance Form 0 Z r4F SO�ryo! --- -- ti o TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INS ATION [ ] FRAMING/STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: C 4 l d DATE ``� ///-INSPECTOR \ OF SO(/r�,Olo �� cOUNi`I,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [�} MECTRICAL (FINAL) REMARKS: DATE �� L INSPECTOR FOLD n!ISPECT3( REPORT DATE COUNTS. FOUNDATION(IST) FOUNDATION(2ND) �y ROUGH FIA1VlIr1CF.& PLtM. ING U INSUL•ATION PER N.y. STATE ENERGY CODE . a FINAL ADDITIONAL C TS TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health. SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. / Check Septic Form N.Y.S.D.E.C. Trustees r Flood Permit Examined ,20 ` Single&Separate Storm-Water Assessment Form Contact: Approved ,20 I Mail to: Disapp a/ Phone: Expirati VVII r "Olio SLOG.DEPL Pl— Building Inspector TOWN OF SOUTHOLD APPLICATION FOR BUILDING PERMIT Date c'• 3 , l 1 , 20 11 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or `areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Pen-nit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building hnspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building inspector may authorize, in writing, the'extension of the pen-nit for an addition six months. Thereafter, a new permit shall be required. APPLICATION iS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name, if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder C�CoR't- � C o►'�"rr g v ter Name of owner of premises (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. 3 y y ?4,— Plumbers License No. C(o Electricians License No. Z to N1 Other Trade's License No. 1. Location of land on which prop sed work will be done: . 6116- Sov e*n GY6 House Number Street Hamlet County Tax Map No. 1000 Section —Block Block Lot Z 7 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Re,5,1 dam} b. Intended use and occupancy 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work*aw R,,o F i- L2 ve r hnn New 5 P i=+g (Description 4. Estimated Cost / 00/ 64c-') Fee Ne4­1 w1e)d90-'' S reSvriF�►�� 1��ctL Epp Show (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures,if any: Front 17'0 / Rear '10 , Depth Z5 Height 19 ' Number of Stories an-e.. Dimensions of same structure. with alterations or additions: Front 4!0 Rear L16� Depth Z Height f 5� Number of Stories on-op, 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front �l'O Rear ----I 7 a Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO g _ �yS Soo� c o racs J�`1G)* 775 -3177 14. Names of Owner of premises Pk-feV 5 o 4a" Address e; oJ.�� Phone N� Name of Architect 6n-,C_ Address Phone No Name of Contractor tad w.c l✓.► o Address Z 75 Phone Nc(G30 Say - 91Sv /✓►A i5 a. Is this property within 100 feet of a tidal wetland or-a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO +/ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are;`there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW PORK) SS: COUNTY OF J being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named., CONNIE.D.BUNCH Notary Public,State of New vor`If (S)He is the No 01BU6185050 (Contractor, Agent, Corporate Officer, etc.) Qualified in Suffolk County Commission Expires Aprii 14,P 0- of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth.in the application filed therewith. Sworn to before me this . -6r-61 day of Gk-r-(L 20�_ Notary Public Signature of Applicant 1 . U. ,, -V- 3417 BUILDING PERMIT EXAMINER CHECKLIST Date Submitted: 6 fir' Date Reviewed. Y_ BUILD r Applicant: Owner: Architect/Engineer: Estimated Cost: ( 00 SCTM# 1000 — j a Subdivision: Zone: T Conforming? Property Address: `o;- ol� City: Pre COs? Building Permits (Open/Expired): BP -Z/00 Z- ,Info: BP -Z/C/O Z- ,Info: BP -Z/C/0 Z- , Info: BP -Z/C/0 Z- ,Info BP -Z/C/o Z- Info: Single& Separate Search Required? Y Determination: S TOP,rAW4Te,P,_ Put�l uFF, OK REQ. Lot Size: ACT. Lot Size: REQ. Lot Cov. ACT: Lot'Cov. REQ. Front ACT. Front REQ Side ACT. Side REQ. Rear PROP. Rear REQ. Height. ACT. Height R E Q.A*TH SIDES_ ACT Project Description: �- Waterfront? Y o If yes, water body: Panel# Flood Zone: B."ulkhead/Bluff Distance: ADDITIONAL APPROVALS REQUIRED pL�N5�+�� SIGNED, s�,��kn su�vty 61'C If yes, *Bed#: *Date: _/_/ *.Permit#: Town Septic: Suffolk County Health: Y or� - If no, certification required: Y or N Received: Y or N By: NYS DEC: PRE-DEC 9/]/75 Y orbl- Date: / / Permit#: or NJ Letter''- Notes: Southold Trustees: Y oitPV - Date: / / Permit#: or NJ Letter=Notes: Southold ZBA: Y otO- Date: / / Permit#: -Notes: Southold Planning: Y ot_ Date: / / Permit#: -Notes: Town Landmark C of A: Y oe-DTE:_/_/_ *NYS CODE Compliance (page 2�cor N hcT CoNTRoR llctNSt AIS�FBlLITy LI/4BIt.iTy. . ..,LI/o�(k.yENS. COAlPF/VS.gT/D,t/ Notes• - Fee Structure: Calculation: Foundation: r' SF X $ ,' 0 =$ First Floor: SF + Initial Fee: $ �L-0 .0r O D Second Floor: SF +Additional Fee (_^): $ Other: SF SF X $ , =$ Total: _7 SF +Initial Fee: $ +Additional Fee $ C OF o FE ,0 A S B u I LT F'EE -$ TOTAL: $ 14 r,, 6 0 NEW YORK STATE CODE COMPLIANCE CHECKLIST CLIMATIC/GEOGRAPHICDD SIGN CRITERIA: Ground Snow Load:2.p , Wind Speed: 12OMPH Seismic Design Category:B Weathering: Severe -Frost Depth: 36" Termite: M-H' Decay: S-M Design Temp: II -lee Shield Underlay:YES Flood Hazards: USE/OCCUPANCY CLASSIFICATION: HEIGHT&ME AREA: TYPE OF CONSTRUCTION: DESIGN CRITERIA: ENGINEERED/PRESCRIPTIVE FULL FRAMING DESIGN ELEMENTS: Y/N HEADERS: Y/N WALL STUDS: Y/N GIRDERS: Y/N CEILING JOISTS: Y/N jFLOOR JOISTS:Y/N ROOF RATTERS: Y/N LUMBER SPECIES AND GRADE: Y/N WINDOW AND DOOR SCHEDULE: •MISSLE TEST REQUIREAlENTS: Y/N EGRESS 5.7 S.F.: Y/N 4 LIGHT 8%: Y/N N,ENT 4%: Y/N NAILING/CONSTRUCTION SCHEDULE: YIN MEANS OF EGRESS: YIN PLUMBING RISER DIAGRAM: Y/N LOCATION OF FIRE PROTECTION EQUIPMENT: YIN TRUSS DESIGN: Y/N CERTIFICATION: Y/N ENERGY CALCS: Y/N (RESCHECK) TOTAL COMPLIENCE? Y/N (RETURN TO PAGE ONE) eos � Town of Southold J Erosion, Sedimentation & Storm-Water Run-off ASSESSMENT FORM PROPERTY LOCATION: S.C.T.M.#: THE FOLLOWING ACTIONS MAY REQUIRE THE SUBMISSION OF A i J() S STORM-WATER,GRADIN ,DRAINAGE AND EROSION CONTROL PLAN -rs nct ge 'onn- Bloc— c(— R�_ GCERTIFIED BY A DESIGN PROFESSIONAL IN THE STATE OF NEW YORK. SCOPE OF WORK - PROPOSED CONSTRUCTION ITEM# / WORK ASSESSMENT Yes No a. What is the Total Area of the Project Parcels? I Will this Project Retain All Storm-Water Run-Off (Include Total Area of all Parcels located within Generated by a Two(2")Inch Rainfall on Site? the Scope of Work for Proposed Construction) (S.F.!Aces) (This.item will include all run-off created by site �/— ❑ b. What is the Total Area of Land Clearing clearing and/or construction activities as well as all and/or Ground Disturbance for the proposed Site Improvements and the permanent creation of construction activity? ($.F./Acres) impervious surfaces.) • 2 Does the Site Plan and/or Survey Show All Proposed PROVIDE BRIEF PROJECT DESCREMON (ProvideAdditionall Pages as Needed) Drainage Structures Indicating Size&Location?This Item shall include all Proposed Grade Changes and Er nn Slopes Controlling Surface Water Flow. 3 Does the Site Plan and/or Survey describe the erosion VJ S G Vl and sediment control practices that will be used to control site erosion and storm water discharges. This — ,l V, item must be maintained throughout the Entire Construction Period. 4 Will this Project Require any Land Filling,Grading or Excavation where there is a change to the Natural — Existing Grade Involving more than 200 Cubic Yards F-1 of Material within any Parcel? 5 Will this Application Require Land Disturbing Activities Encompassing an Area in Excess of Five Thousand ❑ — (5,000 S.F.)Square Feet of Ground Surface? 6 Is there a Natural Water Course Running through the Site? Is this Project within the Trustees jurisdiction General DEC SWPPP Requirements: or within One Hundred(100')feet of a Wetland or- Submission of a SWPPP is required for all Construction activities involving soil Beach? disturbances of one(1)or more acres; including disturbances of less than one acre that 7 Will there be Site preparation on Existing Grade Slopes are part of a larger common plan that will ultimately disturb one or more acres of land; which Exceed Fifteen(15)feet of Vertical Rise to ❑ — including Construction activities involving soil disturbances of less than one(1)acre where One Hundred(100')of Horizontal Distance? the DEC has determined that a SPDES permit is required for storm.water discharges. (SWPPP's Shall meet the Minimum Requirements of the SPDES General Permit 8 Will Driveways,Parking Areas or other Impervious for Storm Water Discharges from Construction activity-Permit No.GP-0.10.001.) Surfaces be Sloped to Direct Storm-Water Run-Off ❑ — 1.The SWPPP shall be prepared prior to the submittal of the Not.The NOI shall be into and/or in the direction of a Town right-of-way? submitted to the Department prior to the commencement of construction activity. 2.The SWPPP shall describe the erosion and sediment control practices and where 9 Will this Project Require the Placement of Material, required,post-construction storm water management practices that will be used and/or Removal of Vegetation and/or the Construction of any ❑ constructed to reduce the pollutants in storm water discharges and to assure Item Within the Town Right-of-Way or Road Shoulder compliance with the terms and conditions of this permit In addition,the SWPPP shall Area?(This Item will NOT Include the Installation of Driveway Aprons.) Identify potential sources of pollution which may reasonably be expected to affect the quality of stone water discharges. NOTE: If Any Answer to Questions One through Nine Is Answered with a Check Mark 3.All SWPPPs that require the postconstruction storm water management practice in a Box and the construction site disturbance is between 5,000 S.F.&1 Acre in area, component shall be prepared by a qualified Design Professional Licensed In New York a Storm Water,Grading,Drainage&Erosion Control Plan is Required by the Town of that is knowledgeable in the principles and practices of Storm Water Management Southold and Must be Submitted for Review Prior to Issuance of Any Building Permit (NOTE: A Check Mark(4)and/or Answer for each Question is Required for a Complete Apprication) STATE OF NEW YORK, / COUNTY OF.��.... ..��C.................SS That I..................................Wj;I--I....-...oc--u-.........................being duly sworn,deposes and says that he/she is the applicant for Permit, (Name of Individual signing Document) And that he/she is the .......................................... .. .. (owner,Contractor,Agent.Corporate Officer,etc.) Owner and/or representative of the Owner or Owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to dAbest of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed herewith. Sworn to before me this j G..............day of... .. . 20.. 7 � { 1 C- -nl�� AF -S �von� Notary Public: ..........................Ktkit s t::1it htvc ................................... ....................................... I hlQt=Public-State of w York (Signature f Applicant) FORM - 06/10 No.4924475 f Qualified in Nassau County Commission Expires Feb.22, *pF SO�ryolo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 CA Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD October 27, 2011 Peter Bohan 11 Cambridge Avenue Stewart Manor, NY 11530 RE: 645 Southern Cross Road, Cutchogue TO WHOM IT MAY CONCERN: The Following Items Are Needed To Complete Your Certificate of Occupancy: Application for Certificate of Occupancy. (Enclosed) \*Electrical Underwriters Certificate. A fee of$50.00 Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 411/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. BUILDING PERMIT : 36482-Z alterations ' n r _ LO •-? �.: 1l(S 5,yUt2UE Y t}i}r 6 EE,� ` v•► L,k m co Ta ie.e«y"w.»s won l4�Dt J74,t1 Wr5ET8�c1C �► •�1! ��.bd.r':r'"D n 1 w...a nr.hW ma r+.w.d to ,r rr..+riaiewM r run =+tea OS Qan.-ntdwr� &A"-n w fV Met,.� Mav o,- r , .�J•"" Ro+K'E••R r r•• r SG AR vE YEO F"O4 `v ro dT �?fUL/O ANo JUSAIV =wk.. �n4r•r Mfx. A T �' ••v r -.:p• �,I�-fl?f'I•F: _ • 7!i ��'E :i(=/' ••7- �. .1 T'-7/kc S.- i• :�n,•r:r.,I+;.,: 0OF Hr)y i .�Cd_�r:c Sc �G1ri JrJL�1� S�Cf7'Ci� �.7, �•=�/,?c.r. r a ��+ f�. ��-.,.- %-...�.•• l�lII co 1 UJ COMPLY WITH ALL CODES OF APPROVED AS NOTED NEW YORK STATE & TOWN CODES �� �� AS REQUIRED DATE_ /�B.P. # DTOW A FEE: �e�d BY SOUTHOL PLANNING BOARD NOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE I D( l (� [ so JLDTOWN SiEES FOLLOWING INSPECTIONS: DEC1. FOUNDATION -TWO REQUIRED i I Y.S. E FOR POURED CONCRETE J U N 14 2011 2. ROUGH-FRAMING,PLUMBING, STRAPPING, ELECTRICAL 8 CAULKING 3. INSULATION 31.DG.DEPT. 4. FINAL-CONSTRUCTION&ELECTRICAL To,%,'N of•SOUTHOLD MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. r(a�C Mom✓ IC / 'qn�2N�n LG_ rY.�c. - 1 s s ��r~ l Pasfi y„ U z6 ID13 Rcm 0 ve— e C> 6A D J U N 14 2011 BLOG. DEPT. TOWN OF SOUTHOLD r • V b\' V J U N 14 2011 BLDG.DEPT. TOWN OF SOUTHOLD 3L ro Po cc( A!6'0 -- — 16 G Ac�� Ise _ 6 I . 5 Andersen Windows-Abbreviated Quote Report t I Project tame. Ed Gatto}Bohn a w,w.o.sowp — r.,ww .mora Quote#: 49304 Print Date: 03IM011 Quote Date: OW0812011 iQVersion: 11.0 Dealer RI'VERHEAD BUILDING SUPPLY Customer BUILD SMARTER.BUILD BETTER_ Billing 1-800 378-MO Address: W W W.RBSCORP.COM Prone: Fax: Sales Rep: JASON YOUNG Contact: - CSR Name: Item Q y Item Size(Operation) Location Unit Price Ext Price 0003 4 WDH304GE(AA) bedrowns(egress) $ 614AO $ 2459.56 I� ROSiae=3'2118"Wx4'8710"H Unit Size=3'9SWWx4'8718"H Unit,Equal Sash,WhitelClear Pine,High Performance Lots-E4 Glass,Divided Lightwitlh Spacer,Specified Equal Lite,3vd2h,3W,Chamfer,Fad Onle- White, Int Grille-Pine(Each Sash) _ Dual Sash.InsectScrew,White S 0004 1 FWGSNII $ 1698.3E $ 169.35 RO S9ze=8`0"W x 6'11"H Unit SLw=5'Z 1 1 W W x 6'10 318"H Unit,LS Handing,Vfflbp(deer Pine,High Performance Lwow-E4 Tempered Glass GGdMg.Insect Screen,White - L= Hardware Trim Set GD,2 Panel,Newbury-Bright Brass = Lock,GD,LH,E for Keyed,Newbury-Bright Brass a 0005 1 _ VII H18210(AA) $. 3�•Q5 $ 390r85 RD Sloe=9.10 1!8'Vif x 3'0 718"H Unit Siae=1'9 5l8"W x 3'0 718"H Unit,Equal Sash,VMbe161ear Pine,High Performance Low-E4 Glass,Divided L'U t wffll Spacer,Colmdal,2W2H,3147,Chamfer,Ext Grille-White, Int Grille-Pine(Each Sash) L _ Equal Sash,Insect Screen,White 7 f 0007 2 VIIOHMIOE(M) $ $ 10MM IFMI ROShe=2'21187WxVO718"H Un1t$lz+e=.LrJ58"Wx4'O71rH Uril;Equal Sash,WhbbUear Pine,High Performance Lovv-E4 Glass,Divided Lot%-Ath Spacer,Colonial,3W2H,3f4 Chamfer,Ext Grille-White,Int. Grille-Pine(Each Sash) Equal Sash,Insect Screen,Wift V t Quote M 49304 Print Date: 031232011 Page 1 Of 3 10 Version: 11.0 Item Qty aeon Slav(Operation) Location Unit Pfice limit Pdoe 1 V 1 iT L 0008 1 WOH2O210-3(AA5AJ4-AA) ��� �l $ 1502.08 $ 1502.68 J R0Mz7e=V5718'Wx3'0718"H Unit Size=6'5118 Wx3-0718"H Composite Unit,ld hi6elClear Pine,High Performance Low-E4 TopfBc:odomeH6gh Performance Low-E4 TopfBodwWHigh Performance Low-E4 TOP/Bottom Grass,Divided Light vAth Spac erTop1Bottom'DividW Light with Spacer TopABoitom?Dividsd Lightwith Spacer TopafBottom,Mulling Location:Factory (Direct),MUR Type:Narrow Will,Mull Priority:Vertical V Equal Sash,Insect Seen,White- r=�— 0009 1 WOH304SE-2(AA AA) dining morn $ 1271A3 $ 1271.63 t T'! RQ Size=6'4118`Wx4'57W'H Unit Sine=W3318"Wx4'87WH o JJ Composite Unit,WhitalClear Pine,High Performance Low-E4 Top18ottom"High FWlbrmance Low-E4 Topx8oftni Glass,Divided LightvAth Spacer Top Sotltorn'Dfvided Light with SpaoerTop/Boftorn, Mulling Location:Factory(Direct), Mull Type:Narrow Mull,Mull Priority:Vertical Equal Sash,Insect Steen,White 0010 1 FWG90S11(LS) $ 1497+47 $ 1497A7 ROSize=3'0"YIfxV11"H Unit Seine=4'11114"Wx6'103f8"H Unit, LS Handing,Forest GreerdClear Pine,High Performance Low-E4 Tempered Gass Gliding Insect Screen,Forest Gruen Hardware Trim Set.GD,2 Panel.Newharry-Bright Brass O 0011 1 WPW55310(F) picture wlndwv option $ 989.10 $ 989.10 - - R0Size=5'771W'Wx4'0718^H Unl1Sbe=5175116"Wx4.0718"H 9 UWIf WbihMear Pine,High Pedbirnance Low-E4 Glass,Divided Light with Spacer,Colonial-Equal Sash Mgnment,6W41-1,3f4 Ext Wie-Whig Int Grille-Pine 0 C l U l �� ii.-� 1 t.✓c. Cam G �- C��^ r r•_ / �, r r y O V V • V C' Quote#: 49304 Print Date: 0312312011 Page 2 OF 3 iQ Version: 11.0 Item (Af item SEM(Operation) Location Unit Price Ext.Price - Sutbotal 10,SB6.1 Total Load Factor Tax(0.000%) 0.0 Customer Signature 3.950 Grand Total Dealer Signature V All graphics viewed from the extealor Rough opening cUrnenrsions are minimums and may need to be Increased to allow for use of'building wraps or flashinga or sIR panning or brackets or fasteners or o1her It erns. PMect Carnments: 0 9 r C /J C r_ Z O V V V C Quote#: 493D4 Print Data: O312312011 Page 3 OF 3 iQVersion: 19.0 Ti m rTe c RAILING Sc Less Work.More Life. D EC K L I T ES® J U N 14 2011 BLDG.DEPT. TOWN OF SOUTHOLD - DEC 1 • Will I NG T__ _ December 2010 r Contents General Information Introduction...............................................................................................................2 CodeListings............................................................................................................3 Railing Product Choices............................................................................................2 Installation Guidelines -- Railing Systems RadianceRail® System ProductOverview..................................................................................................4 Straight&Angled Rails 5-6 g g a StairRails..........................................................................................................7-9 Ornamental Rail System ProductOverview................................................................................................10 Straight&Angled Rails......................................................................................11 Stair Rails......................................................................................................12-13 • I BuilderRail® System ' ProductOverview................................................................................................14 b Straight&Angled Rails.................................................................................15-16 StairRails......................................................................................................17-19 CapRail Details..................................................................................................20 Care & Cleaning = � Storage....................................................................................................................21 �A Ice&Snow Removal................................................................................................21 I j Removing Mildew&Stains......................................................................................21 RadianceRailTouch-Up...........................................................................................21 ADA Compliant Hand Rail System Component&Installation..............................................................................22-23 Secure - Mount Post System Component&Applications.................................................................................24 ! , Composite&Concrete Installation.....................................................................25 . =tea a I DeckLitese General Information 's Components........................................................................................................26 ToolsRequired.....................................................................................................26 E SafetyPrecautions..............................................................................................26 ; Installation Guidelines LayoutOverview..................................................................................................27 Wiring Instructions.........................................................................................28-29 'D6 yo'U need hel ,With your,installatio _F Component Installation..................................................................................30-33 TimberTech strives to provitle:the very best seryices to our customers..We havellan excellent custom( ustom service Warranty vteam th'atlii,here to Blip you with your installation Warranty Information.........................................................................................34-36 questions. If you need help you can call-customer : Warranty Card.........................................................................................................37 service at 1-800 301 t7780�or visit www.timbertech I -coim/installation''to view TimherTechi installation viileost t yi} Dear Valued Customer: a rZg5 TimberTech would like to thank you for your interest in our railing systems. T We strive to better serve our customers and hope that you have a wonderful experience with TimberTech. TimberTech focuses on quality, innovation and brand in all that we do. With To get information on other TimberTech products visit timbertech.com or ask your an assortment of plank profiles, industry leading railing systems,fencing and dealerforthese installation guides: numerous accessories,building beautiful decks has never been easier. •TimberTech Decking&DrySpace1P°Installation& Maintenance Guide TimberTech is committed to providing builders and professional deck installers •TimberTech FenceScape°Installation&Maintenance Guide with exciting new products our customers demand, as well as programs and TheTimberTech Elite&Premier Contractor Programs benefit Contractors in numerous support material to differentiate themselves in the marketplace. ways,including product training,sales tools,product samples,promotions and TimberTech is a memberof the Crane Building Products family of companies,which marketing programs. is part of the Crane Group,a 60-year old family owned company. To get information on becoming a TimberTech Elite or Premier Contractor log TimberTech has compiled this Railing&DeckLites®Installation &Maintenance onto www.timbertech.com. Guideto provide a thorough resource fortechnical information forour railing systems and deck lighting system. Installing TimberTech TimberTech offers three innovative railing systems. A variety of color choices allow you to match or complement your TimberTech deck planks. ILI Rit RadianceRail® Ornamental Rail BuilderRail® A clean,crisp look with no exposed hardware The look and feel of real wood Black metal balusters with TimberTech BuilderBoard rails TimberTech products are a revolutionary alternative to traditional wood-they don't rot, warp or splinter-and they look great year after year. And unlike wood,TimberTech products require no painting,staining or sealing. Make sure your project meets local building codes before you begin installation. These installation guidelines will direct you through the process of installing TimberTech railing systems.These methods are recommended by TimberTech but may not cover every installation scenario you encounter.Since each installation is unique in its performance requirements,the ultimate installation method used is the sole responsibility of the installer.TimberTech recommends that all designs be reviewed by a licensed architect,engineer or local building official before installation. TimberTech Code Listings ICC Evaluation Service, Inc. Once a product is tested by an independent lab, an application and report is [CC ESR-1400.Ornamental Rail System AN. submitted to one of several agencies that provide listings for building products Underwriters Laboratories, Inc. that meet the requirements of Acceptance Criteria 174(AC 174)as setforth bythe E319591 •DeckLites International Code Council Evaluation Service(ICC-ES).TimberTech currently has listings from the ICC-ES and Architectural Testing Inc.The following TimberTech reports on code compliance are available to download on www.timbertech.com. ATI Architectural Testing, Inc. CCRR-0114•RadianceRail For the most up-to-date code listings visit www.timbertech.com/ CCRR-0129•BuilderRail installation. Test Reports: ADA Hand Rail&Secure Mount Post System tested to requirements of ICC-ES-AC-174 (�Tnnberl�cti 2 LessWwkMwaLifa Railing Product Choices RAILING & RAILING ACCESSORIES size _ { RADIANCERAIL® 6'RadianceRail Complete Kit-Square Balusters 6'length-36"high X X 8'RadianceRail Complete Kit-Square Balusters 8'length-36"high X X 6'RadianceRail Rail Pack 6'length X X X X X X X 8'RadianceRail Rail Pack 8'length X X X X X X X 8'RadianceRail Custom Rail Pack(no pre-drilled holes) 8'length X X X X X X X 6'Baluster Pack-Square Balusters 6'length X X X X X X X 36"high/42"high 8'Baluster Pack-Square Balusters 8'length X X X X X X X 36"high/42"high Top Rail Bulk Component 8'length X X X X X Bottom Rail Bulk Component(no pre-drilled holes) 8'length X X X X X Support Rail Bulk Component 8'length X X X X X Radiance Rail Baluster,Solid Square 12'length X X X X X Hardware Mounting Kit WA Post Cover for 4x4 Post(use with 36"rails) 5"x 5"x 42" X X X X X X X Post Cover for 4x4 Post(use with 42"rails) 5"x 5"x 12' X X X X X X X Post Cap and Post Skirt N/A X X X X X X X ORNAMENTAL RAIL 6'Omamental Rail Kit: 6'length X X X 8'Ornamental Rail Kit: 8'length X X X 6'Baluster Kit,16 Pre-Cut Solid Square,36"rail ht. 1.3"x 1.3"x 27" X X X 8'Baluster Kit,20 Pre-Cut Solid Square,36"rail ht. 1.3"x 1.3"x 27" X X X Post Cover for 44 Post 4.25"x 4.25"x 4' X X X 4.25"x 4.25"x 12' X X X Baluster,Solid Square 1.3"x 1.3"x 12' X X X Post Cap and Post Skirt WA X X X BUILUERRAIL°* i 6'BuilderRail Kit: 6'length Black Classic Metal Balusters 36"high/42"high 8'BuilderRail Kit: 8'length Black Classic Metal Balusters 36"high/42"high 8'BuilderRail Stair Kit: 8'length Black Classic Metal Balusters 36"high/42"high BuilderRail Post Brackets-Black 90, BuilderRail Stair 125' Post Brackets-Black BuilderBoard°Rails 6'or 8'lengths X X X Post Skirt WA X X X Foot Blocks X X X *Use Ornamental Rail Post Covers and Post Skirts with BuilderRail. ADA HAND RAIL SYSTEM Grab Rail with Aluminum Insert 1.5"OD x 104" X X Aluminum Joiner Kit 1"OD x 6" Inside/Outside Corner 1-1/2"OD x 4"x 4" X X Inline Wall Mount Bracket 3" X X Inside Corner 90*Standoff Bracket 6-1/4" X X End Cap 1-1/2" X X Handicap Loop 18"x 12"x 18" X X Adjustable Internal Joiner 90'Return Bracket 3.75"x 3.5" X X External Swivel Connector X X Standoff Bracket 2-1/4" X X SECURE-MOUNT POST SYSTEM Secure-Mount Post 36"-Adjusts to 42"high if needed Deck Mounting Kit(includes leveling kit) N/A 3 (aTOr17�N1 Ra d i a n c e Ra i I° System • Consult your local building codes for Visit www.timbertech.comrinstallation to view TimberTech installation videos. guard and handrail requirements. RadianceRail kits are available in 6'or 8'lengths. Measure Your Railing Area Components Needed For Installing One •Measurements are from center to center of post. Kits are produced to 6' RadianceRail System and 8'to allow forfinished end cuts and angles. Components Included 1-Top Rail •Determine how many 6'or 8'RadianceRail Kits you need and check to be in Complete 6'and 8' 1-Bottom Rail sure you have all the components(and quantities)listed in the chart and Kits(Classic Black and 2-Support Rails shown to the right. Foot Blocks Coastal White Only) _1 in 6'Kits-2 in 8'Kits Important Information Square Balusters -13 in 6'Kits-18 in 8'Kits •RadianceRail 6'and 8'Kits are designed not to exceed 6'and 8'center Hardware Mounting Kit of post to center of post,respectively. Support Block Mounting Templates •For stair applications maximum rail length must not exceed 91"for Baluster Screw Kit residential applications and 87"for non-residential applications. T-20 Torx driver bit •44lumber posts orTimberTech post mount system should be installed plumb. Components available s 1-Top Rail separately for a 1-Bottom Rail •Cut slowly,using a fine tooth saw blade to avoid chipping. mix-and-match rail 2-Support Rails Hardware Mounting Kit systems d Support Block Mountaing Templates Foot Blocks Component Dimensions T-20Torxdlriverbitn8'Kits 2 9° 5^� Baluster Screw Kit-6'Kits VT. Square Balusters13-#8x2"Coated Screws -13 in 6'kits-18 in 8'Kits 13-#8x3" Coated Screws Baluster Screw Kit Baluster Screw Kit-8'Kits 3° m 18-#8x2"Coated Screws 18-#8x3"Coated Screws 5° Hardware included in Hardware Mounting Kit Bottom Rail Top Rail Hardware Kits: 4-Mounting Brackets 9" 4-Support Blocks* r � 1.25° 12-#8x3/4"Screws �0 0 O 6-#8x2"Screws 1.9^ 1.215^ � � Post Cover 16-#80"Green Coated Screws Baluster *Support Block Support Rail Only two support blocks are required for straight and angled sections.Four are required for each stair rail. Tools Required •Miter Saw •7/64"and 3/16"drill bits Additional Components 2-Post Covers •Drill •Tape Measure Needed for Each System 2-Post Caps 2-Post Skirts Post Cap (2) —� Top Rail(1) Mounting Bracket ® Support Rail.(2) m Baluster (18 in 8'kit) Post Cover(2) (11 in 6'kit) Support Btock(4)* Bottom Rail(1) Foot BLock(2 in 8'kit) Post Skirt(2) Support Block Mounting Templates(1 ofeach) (1 in 6'kit) (Detach from carton) I E=r (@ TO11��1? 4 Installing Straight and Angled Rails - RadianceRail 0Install Post Covers I •Trim Post Covers to desired length. 38-1/2" above deck surface is Post Cover optimal for 36" railing heights, but could be longer if desired. If installing DeckLites see page 30 for post component heights. •Slide Post Cover and Post Skirt over post. Cover should slide easily Skirt over post,DO NOT FORCE. •Using a level and shims,plumb the post cover vertically.Taking the time to do this will make the installation process much easier. 4x4 Post © Install Lower Support Blocks •Locate and detach the Support Block Mounting Template from the hardware compartment of the carton. r •Position template at the bottom ofthePostCover,resting itonthetopofthePostSkirt. Template (Note:The template can be used with or without a Post Skirt.Follow the instructions on the template for your application.) •Use template to align Support Block to center of post, pre-drill Support Block with 7/64"drill bit and attach with two#8 x 3"green coated screws. _ ��� •If you do not have the template, position the top of the support block Pest skirt 4"above the deck surface or 2-1/2"above the top of the post skirt centered lefttoright. For angled rail installations - align angled face of Support ©Cut and Pre-Assemble Bottom Block parallel to rail section. Support Rail •Measure the distance between the posts near the bottom and the angle if needed,to the rail run. •Cut the bottom Support Rail to length. Make sure the pre-drilled holes in the Min.21/4" Center screw �Support Rail are not within 2-1/4' of your aligned to raj centerline �B x 2" end cuts. #8 Support Rail Coated Screws •Position Mounting Brackets at each end of the Support Rail,pre drill with 7/64"drill TTT j #Bx3/4" bit and attach with#8 x 3/4"coated screws. Coated Screws — Bracket railfacetflush Straight Section to rail face For straight sections:align bracket face to TTT rail end,and align center screw to rail centerline. Center screw For angled sections:align bracket face to 113 a1gneato — rail centerline angled face,and align center screw to rail centerline. 13 _ ? - •Position Foot Blocks and attach to rail using existing Foot holes or pre-drill using 3/16"drill bit and attach with Blocks #8 x 2"coated screws. Bracket set flush For sections up to 6':Place one Foot Block in Angled Section to rail face the center of the rail. For sections 6'to 8':Space two Foot Blocks approximately at 1/3 intervals on the rail. O Install Bottom Support Rail •Position Rail assembly onto Support Blocks. •Pre-drill 7/64"pilot holes through Post Cover and e en o" Greenn C C000ated Green Coated into post through the holes in the Mounting Brackets. Screws Screws •Secure brackets to posts with#8 x 3"green coated screws. —_— -- — 5 WT!berTech ©Space Baluster and Trim Rails •Measure the distance between the posts at the bottom Support Rail. •Transfer measurement to Bottom Rail. To maximize the Baluster #8x3" spacing between the end Balusters and post, center the Top Support Rail Coated Screws measurement on a pre-drilled hole or half way between two pre- tt,l I i-....1� drilled holes.The space between the end baluster and post can J not exceed 4"and the last hole must not be closer than 2-1/4"to 1 1 the end of the bottom rail. 1 "' •Once the desired layout is achieved,trim the Bottom Rail to length. •Measure the distance between the posts near the top of the post r rnae�t and repeat the Baluster layout process on the top Support Rail. installation PP (facing out) ()Assemble Baluster Bottom Rail •Position and secure Mounting Brackets at each end ofthetop Support " Rail as outlined in Step 3. Coated Screws •Lay out balusters along the top Support Rail,aligning them with the pre-drilled holes.Secure with#8 x 3"coated screws. •Position Bottom Rail,usingthe lipto help align Balusters.Secure with #8 x 2 coated screws. •Tip for Bottom Rail:Partially drive screws into all balusters before driving them in complete. R8x3 d8x3" Green Coated Green Coated Q Install Rail Assembly Screws Sorewa _ Align to _..._ __... ---....._.._.._ .. _......._..... center of • Position rail assembly with lip on bottom rail toward outside of -- post deck,over bottom Support Rail. •Align top Support Rail to center of posts. •Pre-drill with 7/64"drill bit and secure Mounting Brackets to Post Covers with#8 x 3"green coated screws. - — --- — -- -- 0 Install Top Rail & Post Caps • Measure and cut Top Rail to length. Trim both ends to ensure a clean cut,may not be angled. • Using a 3/16" drill bit, pre-drill 4 screw holes down through the top support rail.These will be used with 4-2" screws to attach Cap Top Rail ,. the top rail as shown. • Finish installation by positioning Post Caps, and secure using exterior grade caulk applied to the underside of -- the cap. 1 l l Coated Screws Caution.Screws must be 2" so they won't protrude through the Top Rail. IL k. �TimberTecYi 6 LesvW kMae Life Installing Stair Rails - RadianceRail • Consult your local building codes for guard and handrail requirements. Olnstall Post Covers •Trim Post Covers to desired length.Note:Bottom post cover may be longer Post cover than standard length. •Slide Post Cover and Post Skirt over post.Cover should slide easily over post,DO NOT FORCE. Skirt- ZA 4x4 Post All ©Trim Rails NOTE:Support Rails are rotated 90'for stair rail applications. •Check to ensure that posts and covers are plumb. •Determine measurements and angle as shown in the diagram to the right. •Trim both the top Support Rail and the bottom Support Rail to those dimensions. Test fit rails to check for accuracy. Make sure the pre-drilled holes in the support rail are not within 2-1/4" of the 9rh end cuts. <; •Transfer measurement from bottom Support Rail to Bottom Rail. To equalize the Baluster spacing between the end balusters and posts, Right Wrong center the measurement on a pre-drilled hole or half way between two pre-drilled holes.Trim Bottom Rail. •Trim Top Rail to match top Support Rail. ;r 5t?� A gib ©Drill Baluster Holes It is necessary to drill Baluster screw holes in the top Support Rail. Drill •Snap the Bottom Rail and the top Support Rail together as shown to keep the holes aligned. •Drill 3/16" hole through the top Support Rail using the Bottom Rail holes for alignment, drilling at the same angle used to cut rail ends. •Separate the two rails,once all holes are drilled. Bottom Rail Note:Use a scrap piece of wood with the railing angle as a guide for your drill bit. Top Support Rail/ 7 IT #S x 3" Top Support Rail Coated Screws I J Important OAssemble Balusters •Trim Baluster ends to required angle as shown. 1 • Lay out Balusters along the top Support Rail aligning them with J Start cut attop edge of Balusterto maximize the holes drilled in step 3.Secure with#8 x 3"coated screws. the length. •Position Bottom Rail,using the lip to help align Balusters.Secure with #8 x 2"coated screws. • Tip for Bottom Rail: Partially drive screws into all balusters before Bottom Rail driving them in complete. ) 1 Lip i I (facing out) #Bx2" 1 1 Coated Screws OInstall Lower Support Blocks •Place Top Rail onto the railing assembly and measure the distance from top of the Top Rail to the bottom of the Bottom Rail.Transfer this Marked position dimension(A)to the post cover measuring down of rail end from the desired position of the Top Rail. •Position a scrap piece of support rail that has been cut to the same angle of the stair on mark"A"and place a "o C ;" ___ Place bottom Support Rail mark at location B' (see B). C H Mark"B" and mark position on posts. •Use the template as shown below to position Support Blocks.Support Block must be offset to the H �9 ?T — - -- -- Mark"A" / .. outside of the post. o' i J •Pre-drill with a 7/64" drill bit and secure lower Support Blocks to post with#8 x 3"green coated screws.Align the angled face with the direction of the rail slope as shown. 0Install Bottom Support Rail •Pre-drill with a 7/64"and attach Mounting Brackets to the inside of the Center screwH' bottom Support Rail at each end with#8 x 3/4"coated screws.Brackets rail centerline must be installed to the stair tread side of the rail. • Position Foot Blocks and attach to rail, pre-drill using 3/16" drill bit Bracketsetflush and attach with#8 x 3"screws. to rail face For sections up to 6':Place one Foot Block approximately in the center of the rail. -r— For sections 6' to B': Space two Foot Blocks approximately at 1/3 intervals on the rail. • Position bottom Support Rail between post and pre-drill 7/64" pilot holes through Post Cover and into postthrough the holes in the Mounting I �, Brackets. •Secure Mounting Brackets to posts with#8 x 3"green coated screws. t (�limberTecah 8 Install Rail Assembly • Position rail assembly over bottom Support Rail, and align top Support Rail to center of posts. Rotate Rail assembly out of • Mark ends of top Support Rail. Gently push top Support Rail to way to fasten Support Block the side to obtain necessary clearance to attach Support Blocks. •Attach Support Blocks in marked position.Pre-drill with 7/64"pilot Marked position holes and secure with#8 x 3"green coated screws. — of rail ends •Swing rail assembly back against Support Blocks.Pre-drill 7/64" ; pilot holes and secure Mounting Brackets to posts with #8 x 3" o_ green coated screws. 0 Cap Install Top Rail & Post Caps Top Rail • Position Top Rail over Support Rail. Secure near each end and l along the middle with #8 x 2" coated screws angled upward between the Balusters. l •Position Post Caps and secure using exterior grade caulk applied to the underside of the cap to finish installation. a8X2" Coated Screws f Note:Depending on your angle,the screws used to attach the Top Rail may need to be longer than 2". 1 9 �TimberYi Ornamental Rail System • Consult your local building codes for Visit www.timbertech.comfinstallation to view TimberTech installation videos. guard and handrail requirements. Ornamental Rail kits are available in 6' or 8' lengths. Measure Your Railing Area Components Needed For Installing One •Determine how many 6'or 8'Ornamental Rail Kits you need and Ornamental Rail System check to be sure you have all the components (and quantities) Components 1-Ornamental Top Rail listed in the chart. Included in 6' 2-Universal Rails and 8'Kits Screw Kits 6'Kit: (44)#8 x 3-1/2"Screws Important Information (6)#10 x 3-1/2"Flathead Screws 8'Kit: (55)#8 x 3-1/2"Screws •Pre-drilling is required for all fastener locations. (6)#10 x 3-1/2"Flathead Screws •Heights specified in this guide are for 36"residential use. T-20 torx driver bit •Prior to installation it is recommended that you consult your local building codes. Additional 2-Post Covers •Protective clothing and safety glasses are recommended. Components 2-Post Caps Needed for Each • For all TimberTech products, standard woodworking tools may System 2-Post Skirts be used. One Baluster Kit for each section: •As with any outdoor product,periodic cleaning is recommended. 1-6'Baluster Kit-15 Balusters or 1-8'Baluster Kit-20 Balusters Component Dimensions Tools Required Post Cover •Miter Saw Universal Rail Top Rail •Drill Balusters •3/16"drill bit ❑ �: •Tape Measure I�—2.4" 2.75" 4.25" Post Cap(2)— 91.75" Top Rail Universal Rail(2 � ) Square Baluster 6'Kit:(20) Post Cover(2) 6'Kit:(16) 5"O.0 max ® ® Foot Block 2'O.C.max Post Skirt(2) — C�T11? TCCi? 10 Installing Straight and Angled Rails - Ornamental Rail • Consult your local building codes for guard and handrail requirements. OPrepare Posts •Posts must be positioned no more than 8'on center for 8'kits or 6'on center for 6'kits,and must be plumb. " ' Post Cover •Trim 4x4 post to a minimum of 37"above finished deck surface.*If installing DeckLites see page 30 for post component heights. Fastster •Trim Post covers to desired length. For best results use a miter box. 4"x4"Post in ran 37"min. in ffie ceme each e 3!4"from each end •Slide Post Cover over 44 post. Do not force Post Cover over Post. •Slide Post Skirts over Post Cover. (You will not be able to install Post Skirts once railing is installed.) •Center one baluster on each post face that will receive a rail. Position the bottom of the baluster Peslskrc 5"from the deck surface and attach with#8x 3-1/2"screws. _ Prepare Rail Tdm length •Take measurements between posts for top and bottom rails and transfer these dimensions to the Universal Rails. (If you are installing an angled section, measure rail angle and transfer to Pm dulled Was 5'max Univemal Rails Universal Rails.) •Keep in mind when transferring measurements that the Baluster Retaining Lip on both rails must be installed so that they face the outside of the deck. 1 I • In order to achieve even baluster spacing,center the measurement on a pre-drilled hole or half way I—IUMTS­ between two holes.(Remember to take into account the 2 post mounted balusters.) •The Universal Rails are pre-drilled for proper baluster spacing. If you find that the pre-drilled holes will not give you a balanced look,you may re-space the balusters as necessary.If you decide to alter the spacing,you will need to pre-drill with a 3/16" drill bit. Baluster spacing must not exceed 5"from center to center. Bal— •Once the layout has been determined,trim Universal Rails to length. Ramhhgup •Attach balusters to Universal Rails using the#8 x 3-1/2"screws.Make sure to keep the Baluster qj� j Retaining Lip facing the outside of the deck. s_Attach Rail Assembly to Posts •Once the main rail assembly is complete,slide it over the post-mounted Balusters. The Baluster retaining lip on the Universal Rails must be installed to the outside of the deck. /P,gxg-,Z Ra head Scmws •Using a 3/16"drill bit to drill pilot holes at 30'from horizontal and approximately 15'to the side, sida�ew starting 1 1/4"from the end of the rail. •Secure the rail assembly to the post by driving#10 x 3-1/2" flathead screws through the pilot holes into the post. Do not bury the screw heads fully into the Universal Rail,leave one half of the screw head above the surface. Top Vim 0 Attach Top Rail & Foot Block •Pre-drill through the Universal at first baluster space and every fourth baluster space thereafter ngxa,a Fla maadsca vs _ with a 3/16"drill bit. Place Ornamental Top Rail and secure with#8 x 3-1/2"screws as shown. j •Measure and cut Foot Blocks from the end of a spare Baluster. Position Foot Blocks every 2'on center. Pre-drill Universal Rail with a 3/16"drill bit and secure with#8 x 3-1/2"screws as shown. OmamemalTap Rod © Install Post Caps l •Place Post Caps over post covers and 1 rexa-,R-Sanwa fasten with stainless steel finish nails 1 or exterior caulk. Fnemak i r @TimbwTecfi LesaWmkMoreLila Installing Stair Rails - Ornamental Rail • Consult your local building codes for guard and handrail requirements. Rail Angle QPrepare Posts •Trim post and Post Coverto desired height based on angle of stair. Installi \ Post Cover and Post Skirt. Fasten Baluster in the center and 3/4"from each end. h } © Prepare Rails & Balusters • Determine the angle of the stair rail,then measure the distance between _ posts for top and bottom Universal Rail. Transfer these dimensions as well as the angle of the rail to the Universal Rails. • Determine Baluster spacing as outlined in the Preparing Rails section of the Straight Rail instructions. Once you are satisfied with the baluster' spacing and rail lengths,trim Universal Rails to length. •Pre-drill the Baluster holes in the Universal Rails at the same angle as the stair. It may be helpful to cut a piece of scrap wood to the desired angle and use it as a guide. •Trim the balusters to the required length by cutting the stair angle at each end. •Attach Balusters to the Universal Rails usingthe#8 x 3-1/2"screws.Make sure to keep the Baluster Retaining Lip to the same side. #8x31/2"Screws •Attach a pre-trimmed Baluster to the post using three#8 x 3-1/2"screws. Trim Balusters angle as ll pilot at to rail angle angle as stair rail �L9 Baluster Retaining Lip IC Baluster Retaining Lip GTimberTecfi 12 © Install Rail Assembly O Install Top ornamental Rail •Slide Rail Assembly between posts and let it rest on the post mounted •Trim the Top Ornamental Rail to the dimensions and angle of the top Balusters. Universal Rail. •Secure rails to post by pre-drilling 3/16" holes through the rail 1-1/4" •Place Ornamental Top Rail in place. Pre-drill and secure at the first from the end,as shown. baluster spacing from each end and every fourth space thereafter with #8 x 3-1/2"screws as shown. #100-1/2"Flathead Screws Omamental Top Rail D #8x3-1/2"Screws IY o o: t ate; #100-1/2"Flathead Screws / } © Attach Foot Blocks #8x3-1/2 Screw O Install Post Caps •Determine the location of the Foot •Place Post Caps over post covers and fasten with stainless steel finish Blocks(they should be spaced 2' nails or exterior caulk. on center.) Measure the distance between the step and the bottom of the rail. Cut a Foot Block from the end of a spare baluster to the desired angle and length. Footblocks must be used. FootBlock V � •Pre-drill and secure Foot Block to the bottom Universal Rail using ad #8 x 3-1/2"screw. ___.... 13 (e�TR11Y�C�1 LassW kMore Lila B u i l d e rh i I° System • Consult your local building codes for Visit www.timbertech.comfinstallation to view TimberTech installation videos. guard and handrail requirements. BuilderRail kits are available in 6' or 8' lengths. Components Needed For Installing One BuilderRail Measure Your Railing Area system •Determine how many 6' or 8' BuilderRail Kits you need and check to be Baluster Spacing Template sure you have all the components(and quantities)listed in the chart. •6'and 8'sections should be measured from center-to-center of posts. Classic Metal Balusters 6'Kit: (15) Important Information 8'Kit: (20) •Priorto installation it is recommended thatyou consult your local building 8'Stair Kits: (20) codes. Hardware Mounting Kit •Pre-drilling is required for all fastener locations. Mounting Brackets(4) • Heights specified in this guide are for 36"and 42"minimum rails. #8 x 3"Screws(8) •Post Skirts will not fit properly on the deck if your rail 44 posts are notched Hardware #8 x 3/4"Screws(12) over the rim joist. included in Wand 8'Kits Baluster Connector Kit •Foot Blocks are to be constructed from end cuts of the BuilderBoard.Foot Connectors Blocks may also be purchased. *Stair Kits are 6'Kit: (30) •Protective clothing and safety glasses are recommended. sold separately in 8'Kit: (40) •For all TimberTech rproducts,standard woodworking tools may be used. 8'lengths #10 x 1-1/2"Screws •As with any outdoor product,periodic cleaning is recommended. 6'Kit: (30) 8'Kit: (40) Component Dimensions Post Cover 2-BuilderBoards BuilderBoard 2-Post Covers 2-Post Skirts k Foot Block Deck Plank for Top Rail 3.4" 4.2Y Additional _ #8 x 3-1/2"Foot Block Screws 0 a components needed for TimberTech TOPLoc Face Fasteners or .75' 1.41, I each system #8 x 2-1/2"Color Matched Top Rail Screws 4.25"—►I Foot Blocks 6'Kit:(2) Tools Required •Miter Saw •9/64"drill bit 8'Kit:(3) •Drill • 1/2"drill bit •3/16"drill bit •Tape Measure BuilderBoard(2) Baluster Connector (40 in 8'kit) (30 in 6'kit) Metal Baluster Post Cover(2) (20 in 8'kit) (15 in 6'kit) �t t Post Bracket(4) Foot Block (2 for a 6'kit) Post Skirt(2) — (3 for a 8'kit) @Tim 7e1ecH 14 LessWo&M—Lif, Installing Straight and Angled Rails - BuilderRail O Prepare Posts Post Cover •Posts must be positioned no more than 8'on center,and must be plumb. •Trim 44 post to a height of 35-1/4" (for 36")/41-1/4" (for 42") above finished deck surface. Take care to make cuts as precise as possible. •Trim Post covers to 35-3/8"(for 36")/41-3/8"(for 42"). For best results 4"x4"Post 35-1/4" 35-3/8" use a miter box. (for 36") Post Skirt (for 36") \ •Slide Post Cover over 44 post. Do not force Post Cover over post. 41 1/4" 41-3/8" •Slide Post Skirts over Post Cover.(You will not be able to install Post Skirts (for 42") (for 42") once railing is installed.) f- Note:Post at base of stairs must be left long.See stair instructions on page 18. © Prepare Rails 4-5/8"max •Take measurements between posts for top and bottom rails. Trim BuilderBoard to these dimensions.(If you are installing an angled section, ,- -�-- --- -- --- -- --- -- --- -- -- -- ---x measure rail rail angle and transfer to BuilderBoards before cutting.) CL •Lay the BuilderBoard rails side by side(narrow face up)and mark the center BuilderBoards(narrowface up) of each baluster position. Balusters must not exceed 4-5/8"on center. •For convenience a suggested template is included in kit. © Attach Baluster Mounts and Post Brackets •Drill 9/64"holes along the centerline of both BuilderBoards atthe baluster marks. Holes should be approximately 1-1/4"deep. Top •Attach Baluster Mounts at each pre-drilled location using the provided Baluster Mounts I BuilderBoard #10 x 1-1/2"screws. #10 x 1-1/2"Screw—� •Position Post Brackets flush to the ends of the BuilderBoards. Top Rail: Position on same face as Baluster Mounts. Bottom Rail: Position on opposite face from Baluster Mounts. • Pre-drill with 9/64"bit,and attach with the provided#8 x 3/4" screws. g 9 �—#10 x 1-1/2"Screw Baluster Mounts Pre-Drill 9/64"by 1-1/4" O Attach Foot Blocks Holes Bottom • Install foot blocks approximately 2'on center along BuilderBoard the underside of the bottom rail.2 Foot Blocks are Foot Block Prep. required for a 6'section,3 for an 8'section. — •Foot Blocks are to be constructed from end cuts 34" Drill 3/16"hole Foot Block—� of the BuilderBoard. Foot Blocks may also be Bore 1/2"by purchased. _ 1"deep hole #8x3-1/2"Screw—� •Prepare Foot Blocks by boring a 1/2" hole 1"deep 1-1 Post Bracket-- in the bottom of the block,then drill the rest of the #8x3/4"— way through with'a 3/16"bit. Black Screws •Attach the Foot Blocks to the BuilderRail using#8 x 3-1/2"screws. 15 Tiimberkdi LewWwkMomLd& © Install Bottom Rail & Balusters 0 Install Top Rail •Place bottom BuilderBoard between posts,and align to center of post. Let •Bring the top BuilderBoard into position and align each Baluster with its BuilderBoard rest on the Foot Blocks. respective Baluster Mount. •Pre-drill at Post Brackets with a 3/16"bit and attach with#8 x 3"screws. •Tip:Start at one end with Top Rail angled upward.Work your way down the (note:pre-drill through Post Cover only,not into posts) rail by aligning and lowering the Top Rail onto each baluster. •Slide Balusters over the Baluster Mounts along the bottom BuilderBoard. •Once all Balusters are in position, make sure they are snugly seated on the Baluster Mounts. The top of the top BuilderBoard should be flush with the top of the Post Cover. •Pre-drill at Post Brackets with a 3/16" bit and attach with #80" color matched screws.(note:pre-drill through Post Cover only,not into posts.) Rail and Post Cover �shouldbeflush /#8x3"Black Screws 6 i #80"Black Screws O Install Cap Rail •Finish off the railing system by applying one of TimberTech's solid plank profiles to the top of the rail. TOPLoc Face Fastenersor •Cut the planking so that any seams fall at the center of a post. 8x3 Co�ormatcned i screws Miter the planks at corner posts. •Pre-drill and secure planks at posts using 2 TOPLoc Face Fasteners ) 4 b or#8 x 3"screws positioned 3/4"from the end of each plank and ?, ° 1-1/2"from the edge of each plank. Pre-drill and secure plank ' 3/4"-� to the BuilderBoard every 2'using the same screws. i i TIP:If your rail has stair sections,start installing the cap at the stairs and work your way around from there. Wait until all rail sections are complete before beginning cap installation. (�TimberTech 16 LessWoikhiore Lifer Stairs - BuilderRail The BuilderRail Stair Kit includes angled Post Brackets and Baluster Mounts. These components are 9=1 Angled Angled designed for a rail angle of 350 with a margin of adjustment of 5°. In order to insure proper installation, Baluster o Post ' the angle of your stair rail should be as close to 350 as possible. Mount Bracket • Consult your local building codes for guard and handrail requirements. O Trim BuilderBoard Rails •Make sure your posts are no more than 8'on center,and plumb. •Place a Post Cover over the lower stair post, DO NOT trim lower post or post Cover yet. •Position a BuilderBoard on the stairs against the top and bottom Post Covers. Mark the length and angle on the BuilderBoard at each post. •Trim the ends of the BuilderBoard to your marks. •After checking fit at top and bottom rail locations, trim a duplicate BuilderBoard for the top rail. Trim Bottom Post Position the top rail between Remove the Post Cover and Remove Post Cover and using Using a circular saw,trim the Replace the Post Cover and the posts so that the top of the trim to the stair angle using straight edge,mark a parallel post to the lower set of marks. place a Post Skirt over the rail is flush with the top of the your mark as a guide. line about 1/8"below the lines Post Cover. upper post. Re-position Post Cover over made in the previous step. Mark where the top of the rail post and use it to mark the meets the lower post. This angle of the cut for the post. marks the upper edge of the lower Post Cover. © Determine Position of Bottom Rail •Create a mock-up of a rail section using a couple of scrap pieces of BuilderBoard (cut to the rail angle), two Baluster Connectors and a Baluster. •Position the top rail flush with the top of the Post Cover and mark the top of the bottom rail on the post. •Repeat for the bottom post making sure the rails are positioned properly to run up to the upper post. 17 �TunberTecli LessWokMore Life, 5-7/16"max Prepare Rails *After BuilderBoard rails are trimmed to the length as detailed instep l,you CL _X_____X___X___X_____X___X___X___X___X__X._X__ _ need to make a relief cut at the upper end of the rails to insure a proper fit for the upper post brackets. This only needs to be done on the upper BuilderBoards(narrow face up) ends of both top and bottom rails. •Measure 3/4" along the angled cut and cut back from there at a 450 angle. This modification is not necessary at the low end of the rails. •Lay the BuilderBoard rails side by side (narrow face up)and clamp them together. Make sure the angle cuts are oriented Post Bracket- a as shown and mark the locations for the 3/4' #8x3/14"— baluster connections. Black screws • Determine layout for Balusters and mark along the centerline of the BuilderBoards. 459 Angled Baluster Mount •For convenience,a suggested stairtemplate #10x1-1/2"Screw— is included in kit. Top BuilderBoard T Attach Baluster Mounts and Post Brackets • Drill 9/64"holes alongthe centerline of both BuilderBoards atthe baluster marks. Hales must be drilled at same angle as stair rail. Use one of the angled Baluster Connectors,or a scrap piece of wood cut to the stair angle as a drill guide. Holes should be approximately 1"deep. •Attach Baluster Mounts at each pre-drilled location using the provided screws making sure the angle is aligned properly. ` l Pre-Drill •Position Post Brackets flush to the ends of the BuilderBoards.Top Rail: ` 9/64"by ill Position on same face as Baluster Mounts. Bottom Rail: Position on Holes opposite face from Baluster Mounts. •Pre-drill with a 9/64"bit and attach with#8 x 3/4"color matched screws. a Bottom BuilderBoard l Post Bracket O Install Foot Blocks set into notch •Install Foot Blocks approximately 2'on center along the under-side of the bottom rail.2 Foot Blocks are required for a 6'section,3 for an 8'section. •Foot Blocks are to be constructed from end cuts of the BuilderBoard. Foot Blocks may also be purchased. Foot Block Prep •Prepare Foot Blocks by boring a 1/2"hole 1" ------- Trim to stair deep in the bottom of the block,then follow rail angle with a 3/16"hole through the whole block. Drill 3/16"hole ` Trim Foot Blocks to rail angle making sure Bore1/2 by to maximize the length. P deep hole • In orderto position Foot Blocks,you will need Temporarily install to temporarily install the bottom rail. Pre-drill Post Cover at the bracket bottom rail locations with a 3/16"drill bit. Pre-drill Post Cover only. •Position Foot Blocks so that they fit snug between the bottom rail and the Position and mark stairs,mark their location,then remove bottom rail. Foot Block location •Attach the Foot Blocks at marked locations using#8 x 3-1/2"screws,then reinstall the bottom rail with the provided 3"screws. 9ember` ch 18 L..W.kMc 19. Q Assemble Rail section 0 Install Cap Rail • Install the bottom BuilderBoard, securing it to the post at the brackets •Finish off the railing system by applying one of the TimberTech solid plank with#8 x 3"color matched screws. profiles to the top of the rail.You may want to rout a bullnose edge on the •Place a Baluster over each of the Baluster Connectors along the Bottom end overhanging the bottom post. BuilderBoard. •Pre-drill and secure planks at posts using 2#8 x Y screws positioned 3/4" •Tip:Start at one end with Top Rail angled upward.Work your way down the in from the ends and 1-1/2"from the edge of the plank. Where planks rail by aligning and lowering the Top Rail onto each baluster. fully cover a post without a seam,secure the plank with two screws set at •Next,bring the top rail into position,fitting each Baluster Connector into 1-1/2"in from the sides of the plank and centered on the post. Pre-drill its respective Baluster. It is helpful to have two people perform this step. and secure plank to the BuilderBoard every 2 using the same screws. •Pre-drill the post cover at the bracket hole locations with a 3/16" drill bit and secure the rails to the post with#8 x 3"color matched screws. Referto the instructions on the next page,and the BuilderRail video on timbertech.com/installation for more fN information on fitting the top cap. t AxY Black Screws , 19 �TimlberTecfi LeasWokMoaWla Cap Rail Details - BuilderRail Transitioning from Stair Rail to Straight Rail You will have to make some minor modifications to the cap planks in order to achieve an aesthetically pleasing transition from stair to straight rail sections. The modifications required depend on the profile plank you are using. To watch a demonstration of these modifications,view the TimberTech BuilderRail video on timbertech.com/installation. Solid Plank with Square Edge Trim end to 1/2 angle of stair rail Trim the end of the plank that Cut a notch in the top plank Using a jigsaw set to half the Cut the top planks totheirfinal runs down the stair rail to 1/2 at the mark where the two stair angle,cut along the side length. Make sure to allow of the angle of the stair. Leave planks meet. edge of the plank until you some overhang beyond the the plank long so that you can The notch should be angled meet the notch you just cut. post cover to finish the ends make adjustments later. at roughly 1/2 of the stair Slide the joint together and of the planks. Place the planks in their angle toward the underside checkfit,adjust if necessary. Attach the planks to the post finished position and mark of the plank, and should not with #8 x 3" screws. Start where they come together. penetrate the top surface of the screws 1-1/2" from the the plank. edge of the plank, and angle them so that they go into the post without being visible underneath. (@TimberTecH 20 Care & Cleaning With proper installation and care, TimberTech products will provide years of outdoor living pleasure. Storage cleaners have been found to remove or reduce the stains.Always follow the manufacturer's instructions to achieve maximum results. Areas cleaned may Store TimberTech products undercover to maintain a clean surface. If stored outdoors, lighten;this will require 8-10 weeks exposure to the sun to match the remaining they must be covered with a non-translucent material. product. • All products should be stored flat and on a dry surface. • Stack units with banding and bottom supports aligned. Ornamental Rail,and BuilderRail: Discarding Scrap Product General Cleaning: Scrap can be discarded with normal construction debris. •Soap&Water •CorteClean Care & Cleaning Tree Sap: •Krud Kutter(krudkuttercom) Basic Cleaning Recommendations •Simple Green(simplegreen.com) Although TimberTech products are low-maintenance,TimberTech recommends periodic Spray Paint: •Lift Off#4(liftoffinc.com) cleaning to help maintain the beauty of the product.For best results a cleaner like Oil,Grease: •Krud Cutter(krudcuttercom) eco-friendly Corte Clean(corteclean.com)is recommended.Followthe manufacturers' •Oil Eater(oileatercom) application instructions. A power washer can be used when cleaning your TimberTech products. The BBO,Ketchup,Mustard,Jelly and Jam: recommended maximum pressure is 1500psi.A fan tip nozzle should be used along •Krud Cutter(krudcuttercom) with the proper cleaning product.Spray in the direction of the brush/grain pattern Wine: •Wine Away(wineaway.com) to avoid damaging the product.Use caution not to damage the material and always take the proper safety precautions when operating a power washer. Kool-Aid: •Oxi Clean(oxiclean.com) Ice and Snow For ice removal,either rock salt or calcium chloride may be used without damage to RadianceRail: the surface.However,either of these products may leave a white residue,which may be removed by either rinsing with water,or a mild soap/water solution. General Cleaning: Dirt,Grime,Tannin,and Mildew Stains •Soap&Water •CorteClean TimberTech products are formulated to inhibit mildew growth and minimize staining. Pencil marks or other scuffs: Rinse off yourTimberTech products periodically with a hose.Even if it appears clean,it is •Mr.Clean Magic Eraser importantto prevent build-up of pollen/debris.Mildew stains mayoccurwhere moisture, pollens,and/or dirt are present.Mildew needs a food sourceto grow,which can be grass, RadianceRail Touch-Up: pollens,dirt,debris,wood and wood resins. Cleaners that are recommended for use with TimberTech are: Duplicolor 2-in-1 Automobile Touch-up Paint is recommended for scratches,nicks and scuffs on TimberTech RadianceRail: •Sun Frog Composite Deck Cleaner(sunfrog.com) •For Coastal White use"Gloss White" •Super Deck Composite Deck Cleaner(superdeck.com) •For Classic Black use"Universal Flat Black" •Corte Clean(corteclean.com) •E Z Off Composite Wood Cleaner(sunbritesupply.com) •Thompson's Water Seal—Oxy Action(thompsonswaterseaLcom) , Spot Stains Many stains can be cleaned with soap and water.If the stains have set,the following 21 @Trmber'I�cri LessWokMore W(a ADA Compliant Hand Rail System • Consult your local building codes for guard and handrail requirements. TimberTech's ADA Hand Rail System conforms to the requirements of the American with Disabilities Act(ADA)- it provides a continuous gripping surface through its entire length. It is designed to be an aesthetically pleasing complement to TimberTech's Railing Systems and is easy to install. Components Needed For Installing One ADA Hand Rail System: 104"Grab Rail with aluminum insert ADA 104W .' _ 1.5"OD x104" ADA104B r�t Aluminum Joiner Kit 1"OD x 6" ADAIKT 4„x 4„ 90° Inside/Outside Corner ADAOSCW � 1-1/2"OD x 4"x 4" ADAOSCB P { l Inline Wall Mount ADAIWBW Bracket aDAIWBB ° Inside Corner 900 r Standoff Bracket ADAINCW 6-1/4" ADAINCB � End Cap ADAECAPW ADAECAPB Handicap Loop ~I r 18"x 12"x 18" ADAHDLW e ADAHDLB f Adjustable Internal Joiner AOAAOJ 90 Return Bracket 3.75"x 3.5" ADA90RBW ` ADA90RBB External Swivel Connector �F n ADAEXTW ADAEXTB Standoff Bracketr: � 2-1/4" ADASOBW ADASOBB 22 Handicap Loop Aluminum Joiner Kit Used at the Bottom of Steps or Handicap Ramps Used to Connect Two ADA Tubes or 900 Corner Brackets •Attach top bracket at desired location using appropriate •Cut ADA Grab Rail tube with aluminum insert to desired connectors. length. •Cut Handicap Loop to desired length. •Pre-drill aluminum reinforced ADAtube and joinerwith drill •Connect Handicap Loop to ADA tube using the appropriate bit,and install self-tapping screw provided. connector(Aluminum Joiner or Adjustable Internal Joiner.) •Set Handicap Loop on top bracket,pre-drill with drill bit and install self-tapping screw provided. External Swivel Connector— 0 to 60' • Install desired lower bracket. Used for Step Angles - !P* •Adjust External Swivel to desired angle and install set screw. Adjustable Internal Joiner— 0 to 900 , ,r •Cut ADA Grab Rail Tube with aluminum insert to desired length. Used'for Angles •Insert External Swivel bracket into the ADA tube. •Miter Cut ADA Grab Rail with aluminum insert to desired •Pre-drill aluminum-reinforced ADA Grab Rail Tube and length. bracket with drill bit, and install self-tapping screw •Install Adjustable Internal Joiner inside both ends of the provided. tube. •Pre-drill 90'Corner and Straight Joiner with drill bit, and install self tapping screw provided. Inside/Outside Corner— 900 Used for Inside and Outside Corners 900 Return Bracket •Install two Straight Joiners into the 90'Corner. Used for Both Post and Wall Returns •Pre-drill 900 Corner and Straight Joiner with drill bit and install self-tapping screw provided. •Cut ADA Grab Rail tube with aluminum insert to desired •Cut ADA Grab Rail tube with aluminum insert to desired length. length. •Insert 90'bracket into the ADA tube. •Pre-drill aluminum reinforced tube and bracket with drill •Install counter sunk screws provided through the bracket. bit,and install self-tapping screw provided. •Pre-drill aluminum reinforced tube and bracket with drill bit,and install self-tapping screw provided. Inside Corner Standoff Bracket— 900 Inline Wall Mount Used with 900 Elbow for Inside Corner Applications •Install counter sunk screws provided through the bracket Used for Straight Wall Connections into the mounting surface(corner of post.) •Cut ADA Grab Rail tube with aluminum insert to desired •Place 900 Corner at appropriate location on the bracket. length. •Pre-drill 90'Corner with drill bit,and install self-tapping screw provided •Insert 90'bracket into the ADA tube. pp. •Install counter sunk screws provided through the bracket. •Pre-drill aluminum reinforced tube and bracket with drill bit,and install self-tapping screw provided. Standoff Bracket Used for Rail Applications on Walls or Posts •Install counter sunk screws provided through the bracket into the mounting surface. •Place rail at appropriate location on the bracket. •Pre-drill aluminum reinforced ADA tube with drill bit, and install self-tapping screw provided. •Place End Cap on rail. 23 OTimberT�cfi LessWmkMae Lila Secure-Mount Post System and Deck Mounting Kit Visit www.timbertech.com/installation to view TimberTech installation videos. TimberTech's Secure-Mount Post and Deck Mounting Kit provide a solution for installing railing posts directly onto a deck or porch surface,without the use of a 4A treated post.The Secure-Mount Post is designed for use on composite decks,concrete surfaces and commercial areas. mom 16' e a as Secure Mount Post Deck Mounting Kit Includes 2 Leveling Shims for deck or Includes Leveling Plate,Base Plate concrete applications. and Flange Mounting Hardware. Important Information •It is the responsibility of the installer to meet all code and safety requirements and to obtain required building permits. •Plumb post with level and shim between the deck and post-mount base plate with provided shims,if necessary. •For RadianceRail Applications:use the twelve#10 x 2"stainless steel screws that are included with the Secure Mount Post to replace the 3"green screws for the rail to post connection. •For mounting to concrete,additional mounting bolts must be purchased(See bottom of page 25.) Flange Deck Mount Applications (hardware included) •38 x 6,38 x 8 and 42 x 8 rail applications Install TimberTech Secure-Mount Post with optional TimberTech Flange Deck Mounting Kit that includes Leveling Plate,Base Plate,and Flange Mounting Hardware. 3/8'HEX •42"x 8'rail applications must use through bolt installation HEAD BOLT HER Use 3/8 Hex head bolt,carriage bolt or threaded rod a minimum of 13" in length must W DECX be mounted through the bottom post mount block and deck(as shown).Installer should determine the correct length of the bolt needed. Hardware for this application is not included. WOOD WASHER UF SUPPORT N C�Tn? rT�Ch 24 Composite Applications (hardware included) © Attach Post The Deck Mounting Kit includes Once the TimberTech decking has been installed and the blocking is a Leveling Plate, Base Plate in place,use the base plate of the Secure-Mount Post as a template and Flange Mounting Hardware and mark the four corner holes for the 3/8"x 5-1/2"Hex Head Bolts. for composite applications. ' •Drill four 7/16"holes through the marked holes,drilling through •Whether you are installing the deck plank and the reinforcement blocking below. ��' a 36" or 42" high railing •Align the base plate over the drilled holes. section,the Secure-Mount •Take the Secure-Mount Post and place it on the base plate Post provides the flexibility lining up the holes. for proper attachment ° •Screwthe5/16"leveling set screws intothefourtappedholes. 3is HER with its adjustable Top HEAD BOLT T Mounting Block. • Insert the four 3/8 x 5-1/2 bolts into the drilled 7/16 holes. WASHER •The Secure-Mount Post DECK •Take the bottom plate and line it up with the bolts under the comes packaged and set TimberTech deck plank and the 2x12 support blocking. for a 36" high railing •Install the washer and securely tighten with the included nut application. Al on all four 3/8"bolts. •To use with a 42" Railing •If needed,adjust the leveling set screws to plumb the Secure System,remove the 1-1/4" �' Mount Past. Set screw, located inside • For corner post installations,use the off-set holes of the base the top opening of the Top 2x plate. Attachment Block. F-;:: WOOD WASHER I SUPPORT Once the Secure-Mount Post is securely attached, trim the •Through bolt pattern for NUT TimberTech Post Cover to the desired height and slide it over the 42"x 8'installation. post to begin rail section installation. Once the set screw is removed,slide the Top Attachment Block up approximately 6" and align the bottom opening with the pre-drilled hole of the internal support post.Securely fasten the 1-1/4"set screw and you are ready for the 42"installation. Leveling Plate 1 0 Determine Post Location Placement of the Secure-Mount Post should be measured with a center-to-center measurement of 72"when installing a 6'rail section and 96"when installing an 8'rail section. © Install Blocking Concrete Mount Applications Once you have determined the layout for the Secure-Mount Posts on the deck's (hardware NOT included) substructure,you will need to install blocking between the designated joists. •36"x 6',36"x B'and 42"x 6'rail applications A - Using a doubled 2x12 as the block,secure the block in the joist bay and Install using Flange Mounted attach on at least three sides. TimberTech Secure Mount Post. •At least a#8 x 3"stainless steel or high-quality coated exterior woad screw •42"x 8'rail applications5,�' , for the block attachment is recommended and approved for use in treated Install through bolt(hardware lumber. NOT included). •Staggering 3"screws is recommended. •3/8"Diameter Wedge Anchor recommended for concrete B -Note thatthe wood grain of the 2x12 block must be installed perpendicular applications. to the outside rim joist of the deck. •Through bolt pattern for 42"x 8' NUT • Installation of a perpendicular joist black will be needed to ensure installation. WASHER attachment on all three sides of the blocking. Threaded rod would only be needed , for 42"x 8'rail application and is not BLOCKING included. Threaded rod in a through Joist B bolt application on concrete would SHM�NG Block A Joist need to be used with an anchoring / 1 _ adhesive. 'WEDGE', ANCHOR ////OuteC Joist Rim Joist lock ::!:Nide Rim Joist 25 (@Tmberkcli Imbeffech DeckUtes- Visit www.timbertech.com/installation to view TimberTech installation videos. DeckLites Components Aft Post Lamp Module Post Lamp Module 150WTransformer Accent Light RadianceRail Ornamental Rail 300WTransformer J Medium Cable Guide Silicone Filled &Screw Wire Nuts Stair Riser Light 12/2 AWG Wire (12/bag) (20/bag) Tools Required Important Safety Precautions In addition to a basic tool set,you will need the following INSTRUCTIONS PERTAINING TO A RISK OF FIRE OR INJURY TO PERSONS for installation of DeckLites components. IMPORTANT SAFETY INSTRUCTIONS Lighted bulb is HOT! ® o WARNING—To reduce the risk of FIRE OR INJURY TO PERSONS: Turn off/unplug and allow to cool before replacing lamp. Volt Meter Holee Saw 3/8" 1 Drill Bits: Lamp gets HOT quickly!Contact only switch/plug when turning on. a 7/64" Do not touch hot lens,guard,or enclosure. 1/4" Keep lamp away from materials that may burn. 3/16" Do not touch the lamp at anytime.Use a soft cloth.Oil from skin 0_or_� oloo_> may damage lamp. Spade Bits: 2.5mm Do not operate the luminaire fitting with a missing or damaged cover. 5/8"& 3/4" Allen Wrench SAVE THESE INSTRUCTIONS For information about DeckLites® visit www.timbertech.com/DeckLites. (�Timberlfi 26 TimberTech DeckLites Layout Overview The TimberTech DeckLites system is designed for use with the RadianceRail and Ornamental Rail products. Below is a sample lighting layout showing fixture placement and wiring routes.When laying out the wiring for your deck,keep the following in mind: • Building codes vary by locale,please consult all applicable codes • A maximum of 10 lights(10W ea.)can be attached to a single circuit, before beginning project. and a maximum of 30 lights total can be powered by the supplied 300W transformer.A maximum of 15 lights(1OW ea.)can be powered by the • Modifications must be made to railing components during assemblyto supplied 150Wtransformer. accommodate wiring and fixtures.Do not begin deck construction until you have read the lighting instructions. • The 12AWG secondary supply wire can be buried to a maximum of 6"for routing under deck or other obstacles.The Luminary(unit secondary) • This unit secondary wiring shall be protected by routing in close wires cannot be buried underground. proximity to the luminaire or fitting,or next to a building structure such as a house or deck.The wiring shall not be buried except for a • Luminaries shall not be installed within 10 feet(1.52m)of a pool,spa or maximum 6 inches(15.2cm)in order to connect to the main fountain. secondary wire. • Please contact TimberTech to order additional lengths of wire for connection of the luminaries. • Trim post covers to correct length-see page 30. Accent Light Wire Junction 'I Post Cap Light Transformer Accent Ligh I II �� Outdoor GFCI Outlet 12/2AWG Wire Wire routed under deck Non-Looped / \ j Circuit i —Wire routed between post Wire cannot be �� i and post cover routed inside top Looped ir. / f rail of stairs 1 �� Circuit / il� % �� i Wire routed f, inside top w ' rail assembly Stair Riser Light 27 CI TT!nr 1 Wiring Instructions Looping Main Cables &Voltage Drop 80'Max The DeckLites lighting fixtures are designed to work within a specific voltage range of 10.5V to To F � 12V.As current runs along the main cable and to each fixture in a circuit,voltage drop will Transformer occur.This can lead to insufficient voltage being supplied to the fixtures at the end of the run. To limit voltage drop,it is recommended thatyou loop the main cable on circuits that have long =LoopedCircuit runs with multiple lighting fixtures. Looping of the main wire is not necessary on circuits where all of the fixtures are connected at TO Non-Looped Circuit the same junction,such as the Stair Riser Light circuit shown in the Overview illustration. Transformer __q Wire Connections Connections between the main 12/2AWG cable and the lighting fixtures are made using Wire Polarity the space between the post and the Post Cap or Post Light Module as a junction box. NO When routing the main wire around the deck,leave a loop of extra wire at the top of each post to allow for splicing connections. YES . Ridges Use silicone filled wire nuts with corrosion protection and intended for outdoor use to �g make all connections.They shall be copper,copper alloy, or the equivalent. Go Cross section of ABe sure to MAINTAIN POLARITY by aligning ridges when splicing the main ® 12AWG wire 12/2AWG wires or shorting will occur.Polarity for the 18AWG fixture wires is not critical. When making splices,do not pre-twist wires.Pre-twisting wires can lead to a poor seal inside the wire nut causing corrosion and/or voltage drop. Wire Nut Instructions Wire Capacity for Medium Wire Nut Use the following guidelines for correct usage of wire nuts. # 12 Gage IMPORTANT:Turn off power before installing or removing connector. Product to be used in accordance with Wires 0 1 2 3 local and national codes. 1 2 1. Strip wires 5/8" 3 2. Align frayed strands of conductors. 4 3. Do not pre-twist. Place stripped wires together with ends even,but lead smaller 5 stranded wires slightly ahead of larger solid or stranded wire. oo 6 4. Twist connector onto wires pushing firmly until hand-tight. DO NOT over torque. 7 5. Wipe excess sealant in and around conductors. DO NOT REUSE. 8 9 10 �TnnbeMTech 28 Transformer Connections Consult the instructions provided with the transformer for additional information. E30OW Transformer Power is supplied to the lighting fixtures via 12/2AWG wires connected to the provided transformer. One side of the 12/2AWG wire is connected to the Common terminal (C),the other c 12 13 14 15 side is connected to an Output terminal. When connecting the wires in a loop configuration, polarity of the wire must be maintained. One side of the 12/2AWG wire contains raised ridges 0 m 0 0 m to allow for easy identification(see Wire Connections section). outside„ GFCI Circuit The 300W transformer has multiple output terminals ranging from 12V to 15V. In order to determine which terminal to use for a particular circuit,you will need to use the testing procedure outlined below.The 150W transformer has a single set of Output terminals.Either terminal can be used as the Common(C)and the Output(0),however,polarity must be maintained throughout the loop. 12/2AWG wire Note:300W Transformer pictured- 150W also available Transformer Settings 150 Watt Transformer 300 Watt Transformer On Turns unit on 0 Constant Power On Off Turns unit off A Photocell Control"Auto"—Lights come Auto Photocell Control"Auto"—Lights come on at dusk and go off at dawn on at dusk and go off at dawn 1-9 Photocell Control"On"—Lights stay on for the amount of time indicated below: 4H Stays on 4 hours after dusk 1-Stays on 1 hour after dusk 6H Stays on 6 hours after dusk 2-Stays on 2 hours after dusk 3-Stays on 3 hours after dusk 8H Stays on 8 hours after dusk 4-Stays on 4 hours after dusk 5-Stays on 5 hours after dusk 6-Stays on 6 hours after dusk 7-Stays on 7 hours after dusk 8-Stays on 8 hours after dusk 9-Stays on 9 hours after dusk Voltage Testing Procedure To insure the proper operation of the lighting fixtures, a voltage range of 10.5V to 12V must be supplied to each fixture.Supplying voltage outside this range may lead to undesirable or unsafe operation of the lighting fixtures. To test for proper voltage,do the following: •Connect all fixtures,with lamps installed,to the circuit you are testing. •Connect the ends of the main 12/2AWG wire to the transformer using the 12V terminal.(Polaritymustbe maintained). •Turn on transformer to energize circuit. •Using a volt meter,test the voltage at the first fixture on the loop(high reading), then test in the middle of the run(low reading). •If low reading falls below 10.5V,move non-common loop wire up to the next higher transformer terminal and re-test until proper voltage is achieved. Test all circuits in a similar manner,and adjust voltage up or down as needed. 29 0Tmlber? ki Post & Rail Preparation RadianceRail Ornamental Rail Post & Post Covers Post & Post Covers (The following instructions are for a rail height of 36") (The following instructions are for a rail height of 36") I 0 Trim 4x4 wood posts to 35-1/2"above deck surface. 0 Trim 44 wood posts to 34 1/2' above deck surface. i d Trim Post Covers to length: 37-1/2"for a lit post © In order to provide clearance for wiring between the post and Post 5 © n Cover you must create a wire channel. 39-5/8"for an unlit.post � For best results,use a miter saw with a fine toothed blade to Rout a 112"by 1/2" make Post Cover cuts Check cuts fors square. slot down the post �._. _.._-.. q NOTE:Do not rout a wire OR channel where a rail is to be 0 Feed main 12/2AWG cable between post and Post Covers.(See Chamfer the er a corner mounted. Wire Connections section for more info.) Run wires up corner voids created by 0 If you plan to install a post mounted Accent Light,you must rout a Post Cover Ribs. slot down the post to the desired fixture position.(See Accent Light instructions.) Railing 0 Trim Post Covers to length: 36-1/2"for a lit post _I for_an unlit post,_-_ 0 Install Support Rails and Balusters as normal,DO NOT install Top For best results,use a miter saw with a fine toothed blade to make Rail yet. Post Cover cuts.Check cuts for square. 0 Drill a 5/8" hole through the A © Feed main 12/2AWG cable up or down post using prepared feature. Post Cover on centerline, © (See Wire Connections section for more information) directly above rail Mounting Blocks. Railing © After running all wiring, secure four Cable Guides to Support Rail using#8 0 Install Universal Rails and Balusters as normal,DO NOT install Top x3/4"screws.Use the Cable Guides to ®o b Rail yet. pre-drill holes thru the Support Rail © Drill a 5/8"hole through the Post Cover on with a 3/16"bit. centerline, directly above the Universal Rail. Cable Guide Placement 4 4 4 4 0 After running all wiring, secure four Cable Guides to Universal Rail using #8 x 3/4" screws. Position every 4th Baluster, avoiding Balusters and ° Baluster Mounting Blocks if installed. Use the Cable Guides to pre-drill holes thru the Universal Rail with a 3/16", bit. 0 Make a notch on the centerline of the Top Rail by boring a 3/4"hole centered 112" 0 Make a notch on the centerline of the Top back from the end of the rail,then cut it Rail by boring a 3/4" hole centered 1/2" out to form an open slot. back from the end of the rail,then cut its out to form an open slot. p 0 Attach Top Rails after installation of Accent Lights, but before installation of Post Cap Lights.Use the holes that were pre-drilled © Attach Top Rails after installation of Accent Lights, but before through the Cable Guides to attach the Top Rail. FAILURE TO USE installation of Post Cap Lights. Use the holes that were pre-drilled THESE HOLES MAY RESULT IN WIRE DAMAGE. through the Cable Guides to attach the Top Rail. FAILURE TO USE THESE HOLES MAY RESULT IN WIRE DAMAGE. (@Timbe&cli 30 Installing Post Cap Light Post Lamps must be installed after the rail assembly has been completed. ABefore installing, refer to Post & Rail Preparation section. Q Install the Lens onto the Post Cover as shown. © Remove the Post Lamp Coverfrom the Post Lamp Bottom Housing. >(Cap lled) © Trim excess wire length and make wiring connections to 12/2AWG main cable and other 18/2AWG luminary wires. Check to confirm polarity of main cable connections. Q Coil the connected wires inside the Post Cover and insert the Post Lamp Post Lamp Cover Bottom Housing into the Lens. Check to make sure no wires are exposed or ' pinched between Lens and Bottom Housing. © Install the mounting screws and washers assembled as shown. Watch as screws are installed to ensure that wires are clear of Base Lamp screw tip prior to driving them into the wood Mounting ,� i post Lamp Bottom Lamp post. Tighten only until the silicone washer screw u g begins to compress. Over-tightening could break the Bottom Housing causing perma- Wa her J nent damage. ; i Post Lamp Lens silicone Washer Q Install Lamp. Do not touch the Lamp with hare hands, oil from skin may damage Lamp. Use a soft cloth when i \ handling Lamp.Reinstall Post Lamp Cover and screws. Post Cover Q Install Cap Spring into Post Cap as shown(place finger and thumb on Cap Spring tabs, flex gently until Cap Spring appears slightly bowed, insert Cap Spring into Post Cap approximately at the center of the opening until bowed back ends contact the inside top of the Post Cap then relax finger and thumb pressure). Press Cap Spring into seated position as shown. 4 0 Install Post Cap onto Post Lamp Cover. Cap Spring Installation Lens Orientation Cap Spring Tab RadianceRail UP Ornamental Rail Post Cap 31 (@TmibwTecfi Installing Post Mounted Accent Light Q Accent Light wire channel must be routed during the installation of the Post Cover. The Post Cover and the wood post must be prepared in advance to accommodate installation of the Accent Light. (No post preparation is necessary for RadianceRail.) Routed Channel Corr Accent Light WireA AIf using Ornamental Rail or BuilderRail, prepare the wood post gRouted channel for by routing a 1/2"wide by 1/4"deep wire channel up the center Main Cable of the post on the face where the Accent Light will be mounted. + For main cable, route the center of post or slightly bevel the corner of the 44 post. Post Skirt © Prepare the Post Cover in the following manner: •Cut the Post Cover to the desired length. •Determine the height the Accent Light will be mounted. •Mark the location of the wire hole and the mounting screw holes using the template provided on the instructions that come with the product. •Drill a 3/8"hole for the wire and drill two 7/64"holes for the mounting screws. © If a Post Skirt is used, install it over the wood post before installing the Post Cover. You will not be able to install Post Skirt after Post Cover and Accent Light are in place. Q Remove Accent Light Cover from Accent Light Back Plate by Drill Template loosening Set Screw located at bottom of Accent Light Cover. © Route the Accent Light wire through the wire hole in the Post Cover then invert the Post Cover and allow the wire to extend out the top end of the Post Cover. Q Hold the Accent Light Back Plate loosely in position and slide the Post Cover over the wood post and into the Post Skirt. Make sure the wire is in the routed wire channel. Accent Light O Attach the Accent Light Back Plate to the post using two#8 x Back Plate 3/4"screws provided. #s x 3/4" Screws Accent Light \ Cover Install Lamp.Do not touch the Lamp with hare hands,oil from skin may damage Lamp.Use a soft cloth when handling Lamp. Re-install Accent Light Cover and secure with Set Screw with Allen Wrench. 0 Trim excess wire and make wiring connections. r'` f (See Connections section of manual). Lamp e� l 6 Set Screw (@TimbeffecK 32 Le W kM..Lif. Installing Stair Riser Light Q Locate and mark vertical and horizonta I centerlines for Stair Riser Light location. Q Align cut-out template (provided on the instructions that come with the product) with the centerlines and mark left and right • center points for hole saw cuts. x Lamp rPx Q Cut a 13/4"diameter hole at each center point using a hole saw (hole centers will be 3"apart, 1 1/2"to centerline). Stair Riser Q Mark a horizontal line tangent to the top and bottom edges of the 13/4"holes.Cut along the horizontal lines to finish the cutout as \ Stair Riser Light Housing shown. #6 X r" Wood r Screw Q Trim excess wire length and make wire connection to main circuit wire using wire nuts provided. Check local codes to determine if Stair Cover rLight conduit is required.To connect conduit,remove wire and grommet Set from conduit knock-out,then remove knock-out in rear of housing. Screw Conduit Knock-out Q Remove Stair Riser Light Cover and install Stair Riser Light Housing into opening.Pre-drill with a 1/8"bit and attach with two #6 x 1"flat head wood screws. 0 Install Lamp into socket. Do not touch the Lamp with hare hands,oil from skin may damage Lamp. Use a soft cloth when handling Lamp.Re-install Stair Riser Light Cover and secure with Set Screw with Allen wrench. 33 C@ Timm kcH LessWorkMoreLifa A k-i f'rpt 25-Year Limited Residential Warranty , 10-Year Limited Commercial Warranty Alternative decking materials, rail systems,accessories and the DrySpace deck drainage system Statement of Warranty:This warranty is given to the original purchaser,residential or commercial as the case maybe("Purchaser"),of TimberTech alternative decking materials,rail systems(excluding all metal baluster components of such rail systems and DeckLites,which are covered under separate warranties),and accessories(individually and collectively"Decking Materials")and the DrySpace deck drainage system("DrySpace" and,collectively with the Decking Materials,the"TimberTech Products").This warranty does not extend to fasteners that are not supplied byTimberTech. For purposes of this warranty,a residential Purchaser shall refer to a single-family residential homeowner and a commercial Purchaser shall refer to any Purchaser other than a single-family residential homeowner. TimberTech Limited('TimberTech")warrants to Purchaser that,for a period of twenty-five(25)years(Residential)&ten(10)years(Commercial)from the date of the original purchase,residential or commercial as t the case may be,(the"Term"),under normal use and service conditions,that:(1)the Decking Materials will be free from material defects in workmanship and materials,and will not check,split,splinter,rot or suffer structural damage from termites or fungal decay;and(2)DrySpace will not peel,blister,pit,flake,crack or corrode as a result of manufacturing defects,or as a result of exposure to ocean air(salt spray). All warranties are subject to the exclusions,limitations and restrictions set forth below. Obtaining Warranty Performance:If Purchaser discovers a defect in the TimberTech Products during the Term,Purchaser must,within thirty(30)days from the discovery of the alleged defect but no later than the end of the Term,notify TimberTech in writing,at the following address: TimberTech Limited 894 Prairie Avenue Wilmington,Ohio 45177 Attn:Claims Department Purchaser must include in this notification proof of purchase and a statement explaining the defect.TimberTech may request additional information.After reviewing all information,TimberTech will make a determination regarding the validity of such claim. If TimberTech determines that Purchaser's claim is valid,TimberTech will,at its option,either replace the defective TimberTech Products or refund the portion of the purchase price paid by Purchaser for such defective TimberTech Products(not including the cost of its initial installation). If a residential Purchaser makes a valid warranty claim hereunder during years eleven(11)through twenty-five(25)after the original purchase,then the residential Purchaser's recovery will be prorated as indicated below. If TimberTech is providing replacement materials,it may elect to replace the percentage listed below of boards otherwise meeting the requirements for a claim;if TimberTech is refunding the purchase price,it may elect to refund the percentage listed below of the purchase price of boards otherwise meeting the requirements for a claim. Year of Claim Recovery Lear of Cialm I Recove YearofClaim Recove 11 80% 16 60% 21 20% 12 80% 17 40% 22 20% 13 80% 18 40% 23 10% 14 60% 19 40% 24 10% 15 60% 20 20% 25 10% This warranty shall not cover,and TimberTech shall not be responsible for,casts and expenses incurred with respect to the removal of the defective TimberTech Products or the installation of replacement materials, including but not limited to,labor and freight.The foregoing remedies are the SOLE AND EXCLUSIVE REMEDY FOR BREACH OF ANY WARRANTY. Transfer of Warranty:This warranty may be transferred one(1)time,within the five(5)year period beginning from the date of original purchase by Purchaser,to a subsequent buyer of the property upon which the TimberTech Products were originally installed. Exclusions from Warranty Coverage:TimberTech does not warrant against and is not responsible for,and no implied warranty shall be deemed to cover,any product failure,product malfunction,or damages attributable to:(1)improper installation of the TimberTech Products and/or failure to abide by TimberTech's installation guidelines,including but not limited to improper gapping;(2)use of TimberTech Products beyond normal use, or in an application not recommended by the TimberTech installation guidelines and local building codes;(3)movement,distortion,collapse or settling of the ground or the supporting structure on which the TimberTech Products are installed;(4)any act of God(such as flooding,hurricane,earthquake,lightning,etc.),environmental condition(such as air pollution,mold,mildew,etc.),or staining from foreign substances(such as dirt, grease,oil,etc.);(5)variations or changes in color of TimberTech Products;(6)normal weathering due to exposure to sunlight,weather and atmosphere which can cause colored surfaces to,among other things,flake, chalk,or accumulate dirt or stains;(7)improper handling,storage,abuse or neglect of the TimberTech Products by Purchaser,the transferee or third parties;(8)any fasteners not supplied by TimberTech;or(9)minor dripping from DrySpace. Purchaser is solely responsible for determining the effectiveness,fitness,suitability and safety of the TimberTech Products in connection with their use in any particular application. Limitations:DISCLAIMER OF WARRANTIES:EXCEPT FOR(1)THE EXPRESS WRITTEN WARRANTY CONTAINED HEREIN,AND,(2)THE 25 YEAR LIMITED RESIDENTIAL FADE AND STAIN WARRANTY APPLICABLE TO EARTHWOOD EVOLUTIONS DECKING ONLY(WHICH IS IN ADDITION TO THE WARRANTY CONTAINED HEREIN),TIMBERTECH MAKES NO OTHER WARRANTIES,GUARANTEES OR INDEMNITIES,WHETHER EXPRESS OR IMPLIED,ARISING BY LAW,COURSE OF DEALING,USAGE OF TRADE,CUSTOM OR OTHERWISE,INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTY OF MERCHANTABILITY AND IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ALL SUCH OTHER WARRANTIES,GUARANTEES AND INDEMNITIES ARE HEREBY DISCLAIMED,OVERRIDDEN AND EXCLUDED FROM THIS TRANSACTION FOR THE WARRANTY TERM AND BEYOND THE WARRANTY TERM. Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you. LIMITATION OF REMEDIES AND EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES:TIMBERTECH'S LIABILITIES ARE LIMITED SOLELY AND EXCLUSIVELY TO THE OBLIGATIONS SPECIFICALLY UNDERTAKEN HEREIN, AND UNDER NO CIRCUMSTANCES WILL TIMBERTECH BE LIABLE OR OBLIGATED FOR ANY INCIDENTAL,CONSEQUENTIAL,INDIRECT,SPECIAL,PUNITIVE OR ANY OTHER DAMAGES OF ANY KIND WHATSOEVER(INCLUDING, BUT NOT LIMITED TO,LOST PROFITS,LOST SALES,LOSS OF GOODWILL,USE OF MONEY,USE OF GOODS,STOPPAGE OF WORK,OR IMPAIRMENT OF ASSETS),WHETHER FORESEEABLE OR UNFORESEEABLE,ARISING OUT OF BREACH OR FAILURE OF EXPRESS OR IMPLIED WARRANTY,BREACH OF CONTRACT,FRAUD,MISREPRESENTATION,NEGLIGENCE,STRICT LIABILITY IN TORT OR OTHERWISE,EXCEPT AND ONLY TO THE EXTENT THIS LIMITATION IS SPECIFICALLY PRECLUDED BY APPLICABLE LAW OF MANDATORY APPLICATION.TIMBERTECH'S LIABILITY WITH RESPECT TO DEFECTIVE PRODUCTS SHALL IN NO EVENT EXCEED THE REPLACEMENT OF SUCH PRODUCTS OR REFUND OF THE PURCHASE PRICE,AS DESCRIBED ABOVE. Some states do not allow the exclusion or limitation of incidental or consequential damages,so the above limitation or exclusion may not apply to you.This warranty gives you specific legal rights,and you may also have other rights that vary from state to state. Miscellaneous:This writing is understood and intended to be the final expression of the parties'agreement and is a complete and exclusive statement of the terms and conditions with respect thereto,superseding all prior agreements or representations,oral or written,and all other communication between the parties relating to the subject matter of this agreement. This warranty may not be altered or amended except in a written instrument signed by TimberTech and Purchaser or permitted transferee. No agent,employee or any other party is authorized to make any warranty in addition to that made in this agreement and TimberTech shall not be bound by any such statements other than those contained in this warranty. This warranty shall only be applicable and enforceable in the United States of America. This warranty is effective for purchases(residential or commercial,as the case may be)made on or after January 1,2011. Copyright(c)2011 TimberTech. GITi—31ITT MU. 34 5-Year Limited DeckLites Warranty - Statement of Warranty:This warranty is given to the original purchaser, residential or commercial, ("Purchaser") of TimberTech DeckLites products ("DeckLites"), excluding all lamp and socket components. This warranty does not extend to fasteners that are not supplied by TimberTech. TimberTech Limited("TimberTech")warrants to Purchaser that for a period of five(5)years from the date of original consumer purchase(the"Term"),under normal use and service conditions, DeckLites will be free from defects in material and workmanship,and will not crack,peel,blister or corrode as a result of manufacturing defects. All warranties are subject to the exclusions,limitations and restrictions set forth below. Obtaining Warranty Performance:If Purchaser discovers a defect in the TimberTech Products during the Term,Purchaser must,within thirty(30)days from the discovery of the alleged defect but no later than the end of the Term,notify TimberTech in writing,at the following address: TimberTech Limited • 894 Prairie Avenue • Wilmington,Ohio 45177 • Attn:Claims Department Purchaser must include in this notification proof of purchase and a statement explaining the defect.TimberTech may request additional information.After reviewing all information, TimberTech will make a determination regarding the validity of such claim.If TimberTech determines that Purchaser's claim is valid,TimberTech will,at its option,either replace the defective TimberTech Products or refund the portion of the purchase price paid by Purchaser for such defective TimberTech Products(not including the cost of its initial installation). This warranty shall not cover,and TimberTech shall not be responsible for,costs and expenses incurred with respect to the removal of the defective TimberTech Products or the installation of replacement materials,including but not limited to,labor and freight. The foregoing remedies are the SOLE AND EXCLUSIVE REMEDY FOR BREACH OF ANY WARRANTY. Transfer of Warranty:This warranty may be transferred one(1)time within the Term to a subsequent buyer of the property upon which DeckLites were originally installed. Transfer of this warranty does not extend the Term of the warranty. Exclusions from Warranty Coverage:TimberTech does not warrant against and is not responsible for,and no implied warranty shall be deemed to cover,any damage or loss attributable to: (1)improper installation of DeckLites and/or failure to abide by TimberTech's installation guidelines;(2)use of DeckLites in an application not recommended bythe TimberTech installation guidelines(including,but not limited to,immersion or submersion of the products in water)and local building codes;(3)any act of God(such as flooding,hurricane,earthquake,lightning (or other incidences of excessive voltage),natural disaster,etc.),environmental condition(such as air pollution,mold,mildew,etc.),or staining from foreign substances(such as dirt, grease,oil,etc.);(4)variations or changes in color of DeckLites;(5)normal weathering due to exposure to sunlight,weather and atmosphere which can cause colored surfaces to,among other things,flake,chalk,or accumulate dirt or stains;(6)improper handling,storage,abuse or neglect of DeckLites by Purchaser,the transferee or third parties;(7)use in harsh industrial or marine environments;or(8)any fasteners not supplied by TimberTech. Purchaser is solely responsible for determining the effectiveness,fitness,suitability and safety of DeckLites in connection with their use in any particular application. Limitations: DISCLAIMER OF WARRANTIES: EXCEPT FOR THE EXPRESS WRITTEN WARRANTY CONTAINED HEREIN,TIMBERTECH MAKES NO OTHER WARRANTIES, GUARANTEES OR INDEMNITIES,WHETHER EXPRESS OR IMPLIED,ARISING BY LAW,COURSE OF DEALING,USAGE OFTRADE,CUSTOM OR OTHERWISE,INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTY OF MERCHANTABILITY AND IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE,AND ALL SUCH OTHER WARRANTIES,GUARANTEES AND INDEMNITIES ARE HEREBY DISCLAIMED, OVERRIDDEN AND EXCLUDED FROM THIS TRANSACTION. Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you. LIMITATION OF REMEDIES AND EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES:TIMBERTECH'S LIABILITIES ARE LIMITED SOLELY AND EXCLUSIVELY TO THE OBLIGATIONS SPECIFICALLY UNDERTAKEN HEREIN,AND UNDER NO CIRCUMSTANCES WILL TIMBERTECH BE LIABLE OR OBLIGATED FOR ANY INCIDENTAL,CONSEQUENTIAL,INDIRECT,SPECIAL,PUNITIVE OR ANY OTHER DAMAGES OF ANY KIND WHATSOEVER(INCLUDING,BUT NOT LIMITED TO,LOST PROFITS,LOST SALES,LOSS OF GOODWILL,USE OF MONEY,USE OF GOODS,STOPPAGE OF WORK,OR IMPAIRMENT OF ASSETS),WHETHER FORESEEABLE OR UNFORESEEABLE,ARISING OUT OF BREACH OR FAILURE OF EXPRESS OR IMPLIED WARRANTY,BREACH OF CONTRACT, FRAUD,MISREPRESENTATION,NEGLIGENCE,STRICT LIABILITY IN TORT OR OTHERWISE,EXCEPT AND ONLY TO THE EXTENT THIS LIMITATION IS SPECIFICALLY PRECLUDED BY APPLICABLE LAW OF MANDATORY APPLICATION.TIMBERTECH'S LIABILITY WITH RESPECT TO DEFECTIVE PRODUCTS SHALL IN NO EVENT EXCEED THE REPLACEMENT OF SUCH PRODUCTS OR REFUND OF THE PURCHASE PRICE,AS DESCRIBED ABOVE. Some states do not allow the exclusion or limitation of incidental or consequential damages,so the above limitation or exclusion may not applyto you.This warranty gives you specific legal rights,and you may also have other rights that vary from state to state. Miscellaneous:This writing is understood and intended to be the final expression of the parties'agreement and is a complete and exclusive statement of the terms and conditions with respect thereto,superseding all prior agreements or representations,oral or written,and all other communication between the parties relating to the subject matter of this agreement. This warranty may not be altered or amended except in a written instrument signed by TimberTech and Purchaser or permitted transferee. No agent,employee or any other party is authorized to make any warranty in addition to that made in this agreement and TimberTech shall not be bound by any such statements other than those contained in this warranty. This warranty shall only be applicable and enforceable in the United States of America. This warranty is effective for consumer purchases made on or after January 1,2009. Copyright(c)2009 TimberTech. 35 25-Year Limited Warranty for Metal Baluster Components of Rail Systems with Metal Balusters Statement of Warranty This warranty is given to the original consumer purchaser("Purchaser"),of TimberTech Limited("TimberTech")rail systems utilizing metal balusters. TimberTech warrants to Purchaser that,for a period of twenty-five(25)years from the date of the original consumer purchase(the"Term"),that the metal baluster components of TimberTech's rail systems utilizing metal balusters("Metal Balusters")will be free from defects in material and workmanship,including cracking,peeling,blistering of the finish and extensive corrosion(rusting). For purposes of this warranty,corrosion (rusting)is deemed extensive when there are multiple rust-through perforation instances on the same piece of product. All warranties are subject to the exclusions,limitations and restrictions set forth.below. Obtaining Warranty Performance If Purchaser discovers a defect during the Term,Purchaser must,within thirty(30)days from the discovery of the alleged defect but no later than the end of the Term,notify TimberTech in writing, at the following address: TimberTech Limited 894 Prairie Avenue Wilmington,Ohio 45177 Attn:Claims Department Purchaser must include in this notification proof of purchase and a statement explaining the defect. TimberTech may request additional information. After reviewing all information,TimberTech will make a determination regarding the validity of such claim. If TimberTech determines that Purchaser's claim is valid,Timberfech will,at its option,either replace the defective part or refund the portion of the purchase price paid by Purchaser for such defective part(not including the cost of its initial installation)according to the proration schedule set forth below.This warranty shall not cover,and TimberTech shall not be responsible for,costs and expenses incurred with respect to the removal of the defective Metal Balusters or the installation of replacement materials, including but not limited to,labor and freight,as well as shipping charges and sales tax.The foregoing remedies are the SOLE AND EXCLUSIVE REMEDY FOR BREACH OF ANY WARRANTY. If Purchaser makes a valid warranty claim hereunder during years eleven(11)through twenty-five(25)after the original consumer purchase,then Purchaser's recovery will be prorated as indicated below. If TimberTech is providing replacement materials,it may elect to replace the percentage listed below of Metal Balusters otherwise meeting the requirements for a claim;if TimberTech is refunding the purchase price,it may elect to refund the percentage listed below of the purchase price of Metal Balusters otherwise meeting the requirements for a claim. 1-10 years 100%replacement/refund 11—20 years 75%replacement/refund 21—25 years 50%replacement/refund The Purchaser will be responsible for paying any prorated costing. Transfer of Warranty This warranty may be transferred one(1)time,within the five(5)year period beginning from the date of original consumer purchase by Purchaser,to a subsequent buyer of the property upon which the rail system containing Metal Balusters was originally installed. Exclusions from Warranty Coverage This warranty does not cover damage from abnormal or improper use or design,improper product application,accident,alteration,welding,neglect,abuse,lawn care equipment damage, abrasion,harsh chemicals,pool chemicals,or chemicals for ice removal,air pollutants,installation of metal balusters directly on treated(CCA)lumber,improper service or installation or lack of service,or damage caused by flood,fire or acts of God. For product located one(1)mile or less from the coastline,the Term of this limited warranty shall be one(1)year from the date of the original consumer purchase. This limited warranty does not cover Metal Balusters that have come in to direct contact with salt water. Some darkening of the Antique Bronze color is expected to occur over time,and is not a defect or warranty-related issue. Purchaser is solely responsible for determining the effectiveness,fitness,suitability and safety of the Metal Balusters in connection with its use in any particular application. Limitations DISCLAIMER OF WARRANTIES:EXCEPT FOR THE EXPRESS WRITTEN WARRANTY CONTAINED HEREIN,TIMBERTECH MAKES NO OTHER WARRANTIES,GUARANTEES OR INDEMNITIES,WHETHER EXPRESS OR IMPLIED,ARISING BY LAW,COURSE OF DEALING,USAGE OF TRADE,CUSTOM OR OTHERWISE,INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTY OF MERCHANTABILITY AND IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE,AND ALL SUCH OTHER WARRANTIES,GUARANTEES AND INDEMNITIES ARE HEREBY DISCLAIMED,OVERRIDDEN AND EXCLUDED FROM THIS TRANSACTION. Some States do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you. LIMITATION OF REMEDIES AND EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES: TIMBERTECH'S LIABILITIES ARE LIMITED SOLELY AND EXCLUSIVELY TO THE OBLIGATIONS SPECIFICALLY UNDERTAKEN HEREIN,AND UNDER NO CIRCUMSTANCES WILL TIMBERTECH BE LIABLE OR OBLIGATED FOR ANY INCIDENTAL,CONSEQUENTIAL,INDIRECT,SPECIAL,PUNITIVE OR ANY OTHER DAMAGES OF ANY KIND WHATSOEVER(INCLUDING,BUT NOT LIMITED TO,LOST PROFITS,LOST SALES,LOSS OF GOODWILL,USE OF MONEY,USE OF GOODS,STOPPAGE OF WORK,OR IMPAIRMENT OF ASSETS),WHETHER FORESEEABLE OR UNFORESEEABLE,ARISING OUT OF BREACH OR FAILURE OF EXPRESS OR IMPLIED WARRANTY,BREACH OF CONTRACT,FRAUD,MISREPRESENTATION,NEGLIGENCE,STRICT LIABILITY IN TORT OR OTHERWISE,EXCEPT AND ONLY TO THE EXTENTTHIS LIMITATION IS SPECIFICALLY PRECLUDED BY APPLICABLE LAW OF MANDATORY APPLICATION.TIMBERTECH'S LIABILITY WITH RESPECT TO DEFECTIVE PRODUCTS SHALL IN NO EVENT EXCEED THE REPLACEMENT OF SUCH PRODUCTS OR REFUND OF THE PURCHASE PRICE,AS DESCRIBED ABOVE. Some states do not allow the exclusion or limitation of incidental or consequential damages,so the above limitation or exclusion may not apply to you.This warranty gives you specific legal rights, and you may also have other rights that vary from state to state. Miscellaneous This writing is understood and intended to be the final expression of the parties'agreement and is a complete and exclusive statement of the terms and conditions with respect thereto, superseding all prior agreements or representations,oral or written,and all other communication between the parties relating to the subject matter of this agreement.This warranty may not be altered or amended except in a written instrument signed by TimberTech and Purchaser or permitted transferee.No agent,employee or any other party is authorized to make any warranty in addition to that made in this agreement and TimberTech shall not be bound by any such statements other than those contained in this warranty. This warranty is effective for consumer purchases made on or after January 1,2011. Copyright©2010 TimberTech @TimberTecfi 36 LessW kMo�e LiEa Every TimberTech product is backed by exceptional customer service and a commitment to quality Warranty Registration is Easy • The easiest way to register a warranty is to visit www.timbertech.com and select the Warranty&Care link,then select Register Online. • You may prefer to fill out the Warranty Card below and mail it to TimberTech,accordingly to the instructions on the card. Remember,to ensure your product is covered by the TimberTech Warranty it must be installed properly. TimberTech LTD disclaims any liability or responsibility for the improper installation of this product.The purchaser is solely responsible for compliance with applicable local codes as to the deck's intended use.TimberTech recommends all designs be reviewed by licensed architect,engineer or local building official before installation. TimberTech maintains a list of physical properties to assist the design professional. Below is a chart showing which product each warranty covers.You can view warranty details online at www.timbertech.com: • Limited 25-Year Residential Warranty/Limited 10-Year Commercial Warranty Decking:DockSider,Floorizon,ReliaBoard Plank,ValuPlank,Earthwood,TwinFinish,XLM Railing:Ornamental Rail,RadianceRail,BuilderRail(excluding all metal baluster components of BuilderRail System), Secure-Mount Post System,ADA Hand Rail System Fencing: All FenceScape products Accessories:CONCEALoc,DrySpace • Limited 10-Year Warranty for Metal Baluster Components of BuilderRail System • Limited 5-Year Warranty for DeckLites System To Make a Claim To make a claim under either warranty, purchaser or the transferee, must send to TimberTech, within the warranty period referred to above, a description of the claimed defect and proof of purchase.Warranty Information Packets can be obtained from TimberTech. TimberTech Limited Attn: Claims Department • 894 Prairie Avenue,Wilmington,Ohio 45177 • Or call 1-800-307-7780 — — — — --.— — — — — — —-- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — I , ' TimberTech Customer: Name: Purchase Date: I 1 , ' Please complete this War- Street Address: , I , ' ranty card and mail to: City: State/Province: Zip/Postal Code: , � Country: Phone: ' I , TimberTech I 894 Prairie Avenue Product Information: Where was your product purchased? , Wilmington Ohio 45177 I � How was your product installed? , Attn:Warranty ❑Contractor Name: Self-Installed ' I , Warranty Registration: Check the TimberTech product that you purchased: � I This information will help Decking: Earthwood Evolutions"''Plank � ReliaBoard mPlank � Accessories: � I , I us better serve your needs. ❑ Floorizon-Plank ❑ XLM®Plank I , Please return warranty card within ❑ DockSider'm Plank TwinFinish-Plank r I I 30 days of receipt of product. Railing: ❑ RadianceRail® ❑Ornamental Rail ❑ BuilderRail® Metal Balusters , ' 1 ❑ Secure-Mount System ADA Hand Rail System , I , DrySpace" ❑ DeckLites® ❑ FenceScape- I , ' Demographic Information: Number of residents in household: I , Number of household residents in the following age groups: , ' E 0-12 ❑13-18 E]19-27 28-39 ❑40-55 ❑55+ 1 , (91mberTech Average household income: I I , ' Less Work.More Life. ❑Under$35,000 E]$35,000-50,000 [:)50,000-70,000 ❑$70,000-95,000 ❑ $95,000+ I I 37 �e T1117r�C11 IesswarkMoreLifa It's not just a deck. It's TimberTech. I � i I 1y�pyii iil�idal_tn��`ll�ol�ioi c7 MM I CrutlhaliSuTai,siOil (TimberTech 894 Prairie Avenue • Wilmington,OH 45177 • www.timbertech.com • 1-800-307-7780 Less Work.More Life. LIT-RAILINSTALL 12110 C(q Printed on recycled paper. ©2010 TimberTech. Printed in the US.A. a , „ '� .. .� °� ' +ri t' � , �, .;�� .� .. ¢;; - � �_ _. _ .� , + ''` ..� .,�, � • _._ • �.-�.,_..-,,. . ,fir r _. ... __. M j 1� N i t �, ".' i � . J +` t�n !. �� �' 1 —^ • �;�,r a F'� „�I: } � 4 � . �:� f �' 'w i M Ry '. C k Y1} f T h. .4 4 I \,r Ff �. �;, � �:" � .. .-. - �,, �" •• `` � • ;; �_ - +�K i �'� ��.s� �,. .; �� , ._ 4 si � .C4.. Ic .� -A:i Mn �k�n ' ��` `La A�"'Y `. ..-.. � :, a���, ^� Fs�a.Y �h. �, • �` e s"'