Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
36651-Z
Town of Southold Annex 8/26/2011 �o�OgUFFO(,��oG y 54375 Main Road co cox Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 35179 Date: 8/26/2011 THIS CERTIFIES that the building AS BUILT DECK Location of Property: 1995 VILLAGE LANE ORIENT,N.Y. 11957, SCTM#: 473889 Sec/Block/Lot: 25,342.1 Subdivision: - Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this offiiced dated 4/30/2007 pursuant to which Building Permit No. 36651 dated 8/23/2011 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"deck addition to an existing one family dwelling as applied for. The certificate is issued to Frost,Timothy&Frost,Nina (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED Auth d S' atur TOWN OF SOUTHOLD BUILDING DEPARTMENT Co a TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES . WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 36651 Date: 8/23/2011 Permission is hereby granted to: TIMOTHY TYLER & NINA FROST PO BOX 636 -ORIENT, NY 11957 To: CONSTRUCTION OF AN AS-BUILT DECK ADD. TO AN EXISTING SINGLE FAMILY DWELLING. REPLACES EXPIRED BUILDING PERMIT # 32966 At premises located at: 1995 VILLAGE LANE ORIENT, N.Y. 11957 SCTM-# 473889 Sec/Block/Lot# 25.-3-12.1 Pursuant to application dated 4/30/2007 and approved by the Building Inspector. To expire on 2/23/2013. Fees: PERMIT RENEWAL $75.00 CO -ADDITION TO DWELLING $50.00 $125.00 _� Building Inspector FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 32966 Z Date APRIL 30, 2007 Permission is hereby granted to: TIMOTHY TYLER & WF FROST PO BOX 636 ORIENT,NY 11957 for CONSTRUCTION OF AN AS-BUILT DECK ADDITION TO AN EXISTING SINGLE FAMILY DWELLING.THIS PERMIT REPLACES BP #26583 at premises located at 1995 VILLAGE LA ORIENT County Tax Map No. 473889 Section 025 Block 0003 Lot No. 012 . 001 pursuant to application dated APRIL 30 , 2007 and approved by the Building Inspector to expire on OCTOBER 30, 2008 . Fee $ 75 . 00 r ized Si ature ORIGINAL Rev. 5/8/02 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 26583 Z Date JUNE 15, 2000 Permission is hereby granted to: 6� & 2 6 TIMOTHY T. FROST & WF. 1995 VILLAGE LANE ORIENT,NY 11957 for CONSTRUCTION OF AN "AS BUILT" DECK ADDITION TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR. at premises located at 1995 VILLAGE LA ORIENT County Tax Map No. 473889 Section 025 Block 0003 Lot No. 012 . 001 pursuant to application dated MARCH 31, 2000 and approved by the Building Inspector. Fee $ 75 . 00 Authori a Signature ORIGINAL Rev. 2/19/98 Form No.6 TOWN OF SOUTHOLD: BUILDING DEPARTMENT TOWN HALL 765-1802 . APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter-or ink and submitted to the Building Department with the following: -A. For new building or new. use: 1. Final survey of property with accurate location of all buildings;property lines,streets, and unusual natural or topographic features. 2. . Final Approval from Health Dept.of water supply and sewerage-disposal(S-9.form). 1 Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2110 of 1%1ead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer: responsible€or the building. 6, Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957),non-conforming uses,or buildings.and"pre-existing"land uses: 1. Accurate survey of property showingg all property lines,streets,building and:unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate,of Occupancy is denied, the'Building,Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$SOAO,. Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00, Businesses$50.ft 2- Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occup ncy-$.25 4. Updated Certificate of Occ ancy- $50.00 . 5. Temporary Certificate of ecupancy-Residential$.15.00, Commercial$15.00 Date 23 1 New Construction: Old or Pre-existing Building: (check one) Location-of Property. House No. Street Hamlet Owner or Owners of Property'v777 l Suffolk County Tax Map'No 1000, Section �J Black Lot 1 Subdivision Filed Map. Lot: Permit NQ. SCoC�S �. Date of Permit. 0 'Z 3- 1 1 Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted:$ (� APvlicant Siunature T65.1802 BUILDING DEFT. INSPECTION [ ] FOUNDATION iST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [✓]'FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY REMARKS c DATE d �7 INSPECTOR.,,/ oF s0 cOUNi`I,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] IN L ON [ ] FRAMING /STRAPPING [ FIN [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: 4_4� .3 �s DATE ® ® INSPECTOR � OF SO//Tyo`o o�yCO�'Nc� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSUL ION [ ] FRAMING/STRAPPING [ NAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: DATE Z l INSPECTOR '('� FIELD INSPECTION REPORT DATE COMMENTS II II H FOUNDATION ( 1ST) II II III � � p FOUNDATION (2ND) II II --------------- -_________ TI�� I,I -- ROUGH FRAME & � u PLUMBING I INSULATION PER N. Y. STATE ENERGY CODE u ---------- A li L"� d� FINAL __= ----- O hn ADDITIONAL COMMENTS: t� Iss- H H O z �..f1 a l� ro BOARD OF HEALTH . . . . . . . . . . . . . . . FORM NO. 1 3 SETS OF PLANS . . . . . . . . . . . . . . . T0WN OF SOUTHOLD SURVEY . . . . . . . . . . . . . . . . . . . . . . . . BUILDING DEPARTMENT CHECK . . . . . . . . . . . . . . . . . . . . . . . . . TOWN HALL SEPTIC FORM . . . . . . . . . . . . . . . . . . . SOUTHOLD, N.Y. 11971 TEL: (765-1802 NOTIFY: �lIJICJv l CALL Io1�► ;I;1 (q -R H�a Examined.... .........., 2t�.... MAIL TO :Db Approved.. l!5.........v 9A Permit No. .... ... .........O r'.9 .�., 't..... Disapproved a/c .................................. ....'........ .. ...................................................... (Building tor) ;_. .? APPLICATION FOR BUILDING PERMIT LT�.. 7 _ �� .-----� Date. 3,. 3 , 20.QQ 70V,'N OF SOUTHOLD INSTRUCTIONS a. This application must be completely filled in by typewriter or in ink and submitted to the Building Inspector wi 3 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and giving a detailed description of layout of property must be drawn on the diagram which is part of this application. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector caill issue a Building Permit to the applicant. Such permit shall be.kept on the premises available for inspection throughout the work. e. No building shall be occupied or used in whole or in'part for any purpose whatever until a Certificate of Occupancy shall have been granted by the Building Inspector. APPLICATION IS HEREBY MATE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County, New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions or alterations, or for removal or demolition, as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in build' for necesSa inspect . .p _ .. ..�............ ............. i .tuure of �rraa�rfa corporation) 6 (Mailing address of applicant) Vt q ,1 State whether applicant is c i�er, le agent, architect, engineer, general contractor, electrician, plumber or builder .....................► ��`-'............... ..... :��. ............................. ....................... Name of owner of premises ......�.. mod . ...e ....` r^ ..... �.� ...................... (as on the tax rol� latest deed) If applicant is a corporation, signature of duly authorized officer. ......................................................... (Name and title of corporate officer) Builders License No. .......................... Plumbers License No. ......................... Electricians License No. Other Trade's License No. .................... / Qp / 3 1. Location of land on which proposed work will be done......... ....4....... ................................ ....................... �:i.�: ...................... House Number Strz Hamlet Canty Tax Map No. 1000 Section ........: .... Block ......3........ Lot ...�?:...�...... Subdivision ...................................... Filed Map.No. ............... Lot ............... (Name) 2. State existing use and occupancy of premises and intended use and occupancy\of proposed construction: a. Existing use and occupancy ............... 1�o....� ............ ...................................... .. b. Intended use and occupancy .............. t.................... .. .................................... !. Nurture of work (check winch applicable): New Building ........... Addition .. �.. Alteration p Repair ... v/ .. Removal ............. Demolition ............ Other Work .�.'�.5+\� .�.,(...�..5\ �,6' z (Description) 16 -XL Estimated Cost ....t,Ooo.. l rr\� fee .............................................. (to be paid on filing this application) If dwelling, number of dwelling units .....1...... Number of dwelling units on each floor ................ Ifgarage, number of cars ...................................... If business, cannercial or nuxed occupancy, specify nature and extent of each type of use...................... • Dimensions of existing structures, if any: Front................ Rear ............... Depth ................. 11eight ......................... Number of Stories ...................... Dimensions of same structure with alterations or additions: Front ............... Rear ............... Depth .................... Height .................... Number of Stories ............... Dimensions of entire new construction: font ................ Rear ............... De C '. ";. ? ... Height ......................... Number of Stories ..................... Size of lot: Front .................... Rear . Depth .. 0. Date of Purchase ......�cA8(a[.$-I . Nam of Former Owner`.! .'.���� .� ;?��...�.4' --r�'Lf I. Zone or use district in which premises are situated ............................................................... 2. Does proposed construction violate any zoning law, ordinance or regulation: .......�:0............. 3. Will lot be regraded ..... Will excess fill be removed fran premises: YES NO 4. Norms of Owner of premises !. o m; ... Address \:� ��' Phone No. ...��o4... Name of Architect ...........:........................ Address .............................. Phone No. ............. Name of Contractor ................................... Address ...............................Phone No. ............. 5. is this property within 300 feet of a tidal wetland? * YES .......... NO .......... *IF YES, SWIHO D 1>J N MISIMS HUMT MAY SC IQJIRED. PLOT DIAGRAM J 5 C-� a��_K. Locate clearly and distinctly all buildings, whether existing or proposed, and indicate all set-back dimensions rom property lines. Give street and block number or description according to deed, and show street names and indicate ihedw.r interior or rorrW:!T lr.r, cX S rnlr OF MW YORK, SS (MIT Or ........ i•••' ...•..•••• ....................... ......being duly sworn, deposes and says that he is the applicant tk ne of individual si min contract) bove m abed, eis time ...................... --D 4�.............................. (Contractor, agent, corporate officer, etc.) f: said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this ppl.ication; that: all statemments contained in'th is application are true to the best of his knowledge and belief-; and hat the work will be performed in the nmanner set forth in the application filed therewith. worn to before me this A/62 ......�........(lay of ....... Notary Publi ETHASTATHI8 . e ....- . ......of ..cant)............. NO RY PUBLIC.State of NewYotit (Si No.01ST6008173,Suffolk ty Tema Expires June 8. INSPECTORS Victor Lessard f11'' %�f Fo(�f Principal Building Inspector Curtis Horton SCOTT L. RABBIS, Supervisor Senior Building Inspector Southold Town Hall Thomas Fisher P.O.Box 1179,53095 Main Road Building Inspector ' r!� ��:, ,. , � '�^ '� �`t- Southold, New York 11971 BuildinGarg Inspector �a� �' � Fax (516) 765-1823 Vincent R. Wieczorek Telephone (516) 765-1800 Ordinance Inspector Robert Fisher Assistant Fire Inspector OFFICE OF BUILDING INSPECTOR Telephone (516) 765-1802 TOWN OF SOUTHOLD STOP WORK ORDER TO: YOU ARE HEREBY NOTIFIED TO SUSPEND ALL WORK. AT: TAX MAP NUMBER - -• t5V Pursuant to section f of the Code of the Town of Southold, New York, `you are notified to immediately suspend all work and building activities until this order has been rescinded BASIS OF STOP WORK ORDER: CONDITI NS UNDER WHICH WORK MAY BE RESUMED: Failure to remedy the conditions aforesaid and to comply with the applicable provisions of law may constitute an offense punishable by fine or imprisonment or both. DATED: G' O ` TOWN OF SOUTHOLD 109®PERTY RECORD CAR®- OWNER STREET q95 VILLAGE DISTRICT SUB. LOT ors F'ORMtR bWkR n N Fie-+ ev- S ' e E ACREAGE. �A E/J,S A'-Ik E'N/, i I i IV/{/ C 0 R'� of/�r.:� c-P T� S W TYPE OF BUILDING y� )72 a Y aG Y�T / ).'J. '` 0 L( ` P00(V( I EA V V - RES. -' SEAS. VL. FARM COMM. IND. CB. MISC. LAND IMP. TOTAL DATE REMARKS J J ��;t--7 � -�1.,. '. � J �Crli / �_�f /, I C T'f / A. --f L,•/ - s �S' � IT700 ��O0 /0/�0 /7,y (V�o/P6 SPLI/ ,a57�� �a B.COhEnjV ��f �� 1So 6 `/500 i / v o qo G� `,:'r, e '(Q,7 00. C Nc I;No. (pg, �E i, to '�'-A I AZI3RIAN ,AGE 3 D psi B �p88G/CONf� y ���,f)�lyl�I �L� -PE 11 N 0 N^_.- ) L�F-1)'.s,,.� gdg�1�L _ ,� `" 2 BOVE z L c4 5 V�uer6Acr�- n value C �5c .�I'( Ca r.:i c.-i ;rr G r;-- Tillabe d0 0. k.S Tillable 2 Tillable, 3 Woodland Swampland Brushla d House Plot i z Total pc ec6 r A4 Jpee Tom. 3s M. Bldg. ! .5�� Foundation Bath Extensio 5(�- 3 3 Basement Floors - Extension 4 4 Ext. Walls Interior Finish Ext ib, Z440 / S° 3��q` Fire Place Heat Porch Attic �¢ -7,K 35- Porch Rooms 1st Floor 2- Z YZ = r Patio Rooms 2nd Floor Garage - Driveway O. B. '� \ �.. • _` a®..6L' ♦ �ds TOWN OF SOUTHOLD PROPERTY RECORD CARD OWNER STREET VILLAGE DIST. SUB. LOT FORMER OWNER N E ACR S W TYPE OF BUILDING RES. SEAS. VL. FARM COMM. CB. MICS. Mkt. Value LAND IMP. TOTAL DATE REMARKS Tillable FRONTAGE ON WATER Woodland FRONTAGE ON ROAD Meadowland DEPTH House Plot BULKHEAD Total ;� ��.�__ ■■■rC■!■■■©■■■■!�■�i©'!■el■ NOON■ : . .-� � ■■■■Nie■e�■ ■■�■■■■■■■■Nei■■■■��■ ■■■■� �■■ 100 IN MEL NONE■■■■■■■■■■N■EWEN ■■■ ■11 MOON■NONE ■■■■N■'L'.■■■■ ME MMMSEEWMM ONE ■■i■■'�'�lE■■■■■■■■■■■■■■■■■ , . . , _ NOON■■®■■ems■■■■■■■■■■■■■■■■■■ -- _ . �- ■■��Q■■■■�■■■■■■■■■■■ NOON■■ f _.. - -. .� ■■■■■■EMEMO ■■■■■■ NOON■■NNE■■■■■■■■■�■■■■■■■■■■ Basement Ext. Walls •.. .. Recre Room t o��S�FFO�,�coG Town Hall,53095 Main Road p .G Fax(516)765-1823 P.O.Box 1179 W Telephone(516)765-1802 Southold,New York 11971-0959 col � Sao BUILDING DEPARTMENT TOWN OF SOUTHOLD STOP WORK ORDER TO: Timothy Tyler Frost P.O. Box 636 Orient, NY 11957 YOU ARE HEREBY NOTIFIED TO SUSPEND ALL WORK AT: 1995 Village Lane, Orient TAX MAP NUMBER -1000-25-3-12 . 1 Pursuant to Section 45-8 of the Code of the Town of Southold, New York, you are notified to immediately suspend all work and building activities until this order has been rescinded BASIS OF STOP WORK ORDER: work being done that requires a Building Permit CONDITIONS UNDER 'WHICH WORK MAY BE RESUMED: when a Building Permit is issued by Bldg. Dept Failure to remedy the conditions aforesaid and to comply with the applicable provisions of law may constitute an offense punishable by fine or imprisonment or both. DATED: 4/4/00, doblL W/ John M. Boufis Building Inspe for Zt-`L guFFQA, Southold Town Building Department Permit#• 32966 54375 Main Road Southold,New York 11971 Permit Date: 4/30/2007 o • o ,} (631) 765-1802 y�ip� ,�•� r' Expiration Date: 10/30/2008 Parcel ID: 25.-3-12.1 Dated: 7/21/2011 Applicant: TIMOTHY TYLER&NINA FROST Location: 1995 VILLAGE LANE ORIENT, N.Y. 11957 Work Description: AS BUILT DECK CONSTRUCTION OF AN AS-BUILT DECK ADDITION TO AN EXISTING SINGLE FAMILY DWELLING.THIS PERMIT REPLACES BP#26583 Owner: TIMOTHY TYLER&NINA FROST Address: PO BOX 636 ORIENT,NY 11957 Your BUILDING PERMIT #32966 has been referred to me because you have not responded to requests to obtain your Certificate of Occupancy as required by Southold Town code. Pursuant to 144-15A, of the Southold Town Code, "No building hereafter erected shall be used or occupied in whole or in part until a certificate of occupancy shall have been issued by the Building Inspector." Therefore, you have ten days from the receipt fo this letter to submit a check made out to the Town of Southold in the amount of$75.00 to renew the building permit, or legal action will be taken against you. Should you have any questions, call the building department between the hours of 8:00 a.m. and 4:00 p.m. ----- --- �— PS Form 3800,April 1995 Respectfully Yours, N o H C H N �' o o s. Q. d a - = s �D n� o a m Q . s � � � N �•1 v, w •w p 8Y w m90 CC - �: m to s `D n �' momrtm CD rj> -I m s fD f w CD 0 Q. a (D Michael Verity: ief Building Inspectorcon 0 0 x w Southold Building Department y Z� w o is' L 0 cDQ. ru n CD M � cc: Damon Rallis Zoning Inspector � .0 U\ + ID O��S�FfO(�-coG 0 y 2 Town Hall,53095 Main Road Q Fax(631)765-9502 P.O. Box 1179 Telephone(631)765-1802 Southold,New York 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD February 21, 2003 Timothy T Frost P O Box 636 Orient, NY 11957 Dear Mr. Frost: It has come to our attention that building permit#26583, a deck addition to a single family dwelling at 1995 Village La., Orient SCTM#25-3-121,has expired. In order to rectify this matter, the following is required: 1) Immediate renewal of BP#26583. Please submit a check for$150., payable to the Town of Southold, noting the original permit number. 2) Final Inspection required. Once the permit is renewed, you need to schedule a final inspection. 3) Certificate of Occupancy required. Once you have passed inspection, apply for your certificate of occupancy. Without a certificate of occupancy, you are in violation of Southold Town Code (45-15) &NY State law. If you have any questions,please call 631-765-1802 between 8:00a.m. and 4:00p.m. Sincerely yours, ,edm 16=-=,- uthorized Signature CC: file pF SO�lyolo Town Hall,53095 Main Road Fax(631)765-9502 P.O.Box 1179 v' Telephone(631)765-1802 Southold,New York 11971-0959 �Q oI�cDU ,� BUILDING DEPARTMENT TOWN OF SOUTHOLD June 26th 2006 Timothy T. Frost 1995 Village Lane Orient,N.Y. 11957 RE: 1995 Village La. SCTM#025 0003 012.001 Dear Mr. Frost, Please be advised that your Building Permit#26583 issued June 15th, 2000 has expired. According to the Code of the Town of Southold, a Certificate of Occupancy must be issued prior to use of the structure. To renew your Building Permit,please submit a fee of$150.00 at that time we can schedule an inspection by one of our Building Inspector's. If you have any questions,please call us at 631-765-1802. Respectfully, SOUTHOLD TOWN BUILDING DEPT. SO!/ryol 0 Town Hall,53095 Main Road Fax(631)765-9502 P.O. Box 1179 CA • Q Telephone(631)765-1802 Southold,New York 11971-0959 �0 �yIrou BUILDING DEPARTMENT TOWN OF SOUTHOLD February 13th 2007 Timothy T. Frost P.O. Box 636 Orient,N.Y. 11957 RE: 1995 Village Ln. (As-built deck) 2ND NOTICE SCTM: 25 3 12 1 Dear Mr. Frost, Please be advised that your Building Permit#26583 issued June 15th, 2000 has expired. According to the Code of the Town of Southold, a Certificate of Occupancy must be issued prior to use of the structure. To renew your Building Permit,please submit a fee of$75.00 at that time we can schedule an inspection by one of our Building Inspector's. If you have any questions, please call us at 631-765-1802. Respectfully, SOUTHOLD TOWN BUILDING DEPT. " pF SOUTyOIo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 �Ir4UMy,� BUILDING DEPARTMENT TOWN OF SOUTHOLD FIRST NOTICE December 29'h, 2010 Timothy & Nina Frost P.O. Box 636 Orient, N.Y. 11957 RE: 1995 Village Lane (AS-BUILT DECK ADDITION) SCTM: #1000-25.-3-12.1 Dear Mr. & Mrs. Frost, Please be advised that your Building Permit # 32966 issued April 30th, 2007 has expired. According to the Code of the Town of Southold, a Certificate of Occupancy must be issued before use of the structure. To renew your Building Permit, please submit a fee of $75.00; at that time, we can schedule an inspection by one of our Building Inspectors. If you have any questions, please call us at 765-1802. Respectfully, SOUTHOLD TOWN BUILDING DEPT. �o'03F SO(/ryQlo Town Hall Annex Telephone(631)765-1802 54375 Main Road cn Fax(631)765-9502 P.O.Box 1179 G • Q Southold,NY 11971-0959 �Q I*7 Cow, �� BUILDING DEPARTMENT TOWN OF SOUTHOLD FINAL NOTICE January 261h, 2011 Timothy & Nina Frost P.O. Box 636 Orient, N.Y. 11957 RE: 1995 Village Lane (AS-BLT DECK ADDITION) SCTM: #1000-25.-3-12.1 Dear Mr. & Mrs. Frost, Please be advised that your Building Permit # 33474 issued April 30th, 2007 has expired. According to the Code of the Town of Southold, a Certificate of Occupancy must be issued before use of the structure. To renew your Building Permit, please submit a fee of $75.00; at that time, we can schedule an inspection by one of our Building Inspectors. If you have any questions, please call us at 765-1802. Respectfully, SOUTHOLD TOWN BUILDING DEPT. App•rcve-d Apvi 1 1, 196k- 4. ir<r»= vra ATEcite • 40 r, .SG/R ViY.�D Ov • brie b:�K;�a- 6 ✓•F • f .... FLOYO IF C 4 Hlh1Y 1C 3!M , I ED W. F H�MMEL t :AT • TvwN OFSou77'ia�a ' \�` ` •0 4��• .4 '`� •4 �v SarV+eycd No✓..3�/959 '` ` �� �.'' d �• • ' - ram''' .om W.Van Tay14-so ,c`" `per •� •' \� .: �! '"?'� ' r 6r->ccnPot N•Y• 128-9 71, St T ork .6 Ira6� , f' c iz69 t •� _ � vv` .J r N �ke9c.1� /at'l., CorrS. W SI Ole-, y ,� ►? ^' da"" 2 /o,I!6 s�.r! �► b + /J7 All •i s.f9 Z-S49. f r. NWf'ti` i Z 2 759+.• .. a ,• ' -e•y rreu .� Goa} \ - - M.r..`-A ti � •Vl •. .asp s' f � h '-' - ��k 'a" .. -�� th • � •�`ram•. -" -- -�z .\d . . - � _ - - S r• :. '__,, -/ arc freer., sfu y of Floyd .F,/Cin',�r, wh ' -. •o ) ..^,�.'la-fi� •`• .• (r��.+��. addt� to ..oi!'�no! wrap .�6.�Q. ►.7i/. ..�� .�"• ' •�' !" �,' �� a. Revised April 10,19GI, oc$:Z21/99' `�`�•�.�, � .c. + .:. . �' ..;; •.,• •.�'. - ' '•. - r'� QGV 13Bd Stp'l' t'l,l9:0(5, f1pV. fL,.f47 Top View of Your Deck The Scale is 1/8" : 1' DATE: (o I S oa B.P a to 4�'2" FEE: 5 BY. 16'11" 8'11" 31 3' NOTIFY BUILDING DEPART NT AT 765-1802 9 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1 FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION �.��:- S� rJ `Vy r-t- 4. FINAL - CONSTRUCTION �,AUST BE COMPLETE FOR C.O. 1 ALL CONSTRUCTION SHALL MEET 6 THE REQUIREMENTS OF THE N.Y. ` �•��0�'" STATE CONSTRUCTION & ENERGY CLODES. NOT RESPONSIBL DESIGN OR CONSTRUCTION ERRORS a ... r Cl 4.4 cr IL CL i N ` 3 tt{ � I I _ _ I 1 t 1 a 1 � �7L d��"�-�V�► V r o tea— �� `.T�J��Y—c \� l , of V\«J� (( �X•JY!` oL cc Z x S 5 C cc (n� "re Z�BiCCC1 Beam Cut List The Scale is 1/8" : 1' iF- J I i I� F mil— ---H-- i , C E/ B G� Mark Length Description A 5' 2 1/4" 4x6 No. 2 P.T. SPF B 14 8 4x6 No. 2 P.T. SPF C 181411 4x6 No. 2 P.T. SPF n� .fin �_ �+ P.r. SPF E 4' 4 3/8" 4x8 No. 2 P.T. SPF F 5' 2 1/4" 4x8 No. 2 P.T. SPF G 811111 4x8 No. 2 P.T. SPF H 17' 4x8 No. 2 P.T. SPF 1 31' 8 1/4" 48 No. 2 P.T. SPF J 321811 48 No. 2 P.T. SPF Joist Cut List The Scale is 1/8" : 1' -2- R E (3 (3 (3 (i U G GI GGGGG Fv Q 11 J J J J J J J —C D-- O�D �,�D—N lid P i�D Mark Length Description Usage A 4' 3 3/8" 2x6 No. 2 P.T. SPF Joist B 5' 7 3/8" 2x6 No. 2 P.T. SPF Joist C 6' 11 3/8" 2x6 No. 2 P.T. SPF Joist D 71 2x6 No. 2 P.T. SPF Joist E 9' 4 7/8" W No. 2 P.T. SPF Joist F 10' 8 7/8" 2x8 No. 2 P.T. SPF Joist G 111811 2x8 No. 2 P.T. SPF Joist H 18' 5 3/8" 2x8 No. 2 P.T. SPF Joist 19' 9 3/8" 2x8 No. 2 P.T. SPF Joist J 20' 11" 2x8 No. 2 P.T. SPF Joist K 3' 3 3/8" 2x6 No. 2 P.T. SPF Rim joist L 5' 1/8" 2x6 No. 2 P.T. SPF Rim joist M 71 2x6 No. 2 P.T. SPF Rim joist N 141 8" 2x6 No. 2 P.T. SPF Rim joist 0 181411 2x6 No. 2 P.T. SPF Rim joist P 4' 2 1/4" W No. 2 P.T. SPF Rim joist Q 5' 2 1/4" 2x8 No. 2 P.T. SPF Rim joist R 7' 11 3/8" 2x8 No. 2 P.T. SPF Rim joist S 811111 W No. 2 P.T. SPF Rim joist T 9' 1 1/2" 2x8 No. 2 P.T. SPF Rim joist U 16' 11 3/8" 2x8 No. 2 P.T. SPF Rim joist V 1 T 9 3/8" 2x8 No. 2 P.T. SPF Rim joist W 321811 2x8 No. 2 P.T. SPF Rim joist Joists to be hung from the ledge with joist hangers. Joists to be toe-nailed to beams with 2-1/2" (8d) galvanized nails. Rim joists to be face-nailed to joists & ledgers with 3-1/2" (16d) galvanized nails. Blocking and bridging is not shown, but may be required by your local code. Stringer Layout for Your Stairs The Scale is 1 1 � LO 21 1 ' 1 ' These stairs have 3 risers, and are 18' 4" wide. The tread depth is 13 1/2", and the riser height is 7". Your deck is 1' 9" high. Stringer Layout for Your Stairs The Scale is 1" : 1' C'1*4 N 1 These stairs have 4 risers, and are 6' 9 5/8" wide. The tread depth is 13 1/2", and the riser height is 7". Your deck is 2' 4" high.