Loading...
HomeMy WebLinkAbout34992-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-34088 Date: 11/23/09 THIS CERTIFIES that the building SOLAR PANELS Location of Property: 350 LAUREL WAY LAUREL (HOUSE NO. ) (STREET) (HAMLET) County Tax Map No. 473889 Section 125 Block 4 Lot 24.19 Subdivision Filed Map No. Lot No_ conforms substantially to the Application for Building Permit heretofore filed in this office dated SEPTEMBER 4, 2009 pursuant to which Building Permit No. 34992-Z dated SEPTEMBER 11, 2009 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is SOLAR PANELS ON AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to JOHN J & EILEEN O'BRIEN (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO_ 11277 09/30/09 PLUMBERS CERTIFICATION DATED N/A Au horized Signature Rev. 1/81 l WIn No.6 TOWN O SOUTROL D BUILDING 6RPARTMI� T TOWN FIAL L 765-1802 APIP ,ICATION FOR CRRTMWA.TE Op OCCUPANCY ' applies must be filled in by typewriter or ink Ltd submitted to the Building Department with the following: ror new buffding or new use: I n survey of px+operty with=Mete location of all buildings,property lines,stets,and unusual naturd or topogmaphic features, Final Approval from Ilraltli Dept,of water s%Vly and sewerage-disposal(S-9 fonn).- Appxoval=7= •insfisilation£ions BoardofFiic;Und� nvHters. vvorasta ph,mber certifying that the solder used ju system amuta{jw less than 2J10 of 1%iead'. Comm=ial bruld.w&industrial building,rattI*e res&gees and similar buildi p..,d installations,s ceMifioatc -of Code Compliance&ora arcldteci qr engmeer responsible for the building. Submit Planning Board Approval of Wmplet.id site plan requirements. Dr eating bu4ldings brier to April 911957)noa-eouforw!ng uses,or btndiuis.and.Kpre,.� Accurate"My of property show', all ®tag lid'uses: m'. pro... . 1st1Ps,st#�Cets,building a, p denied;the Building application and cdaisent to inspect Signed by'thee vpP a ' rtifecate ofO 'ccup • S iuspector shall state the reasons therefor in writing to eant. NOV 19. 2009 Certificate of •Oceupancy New,dwelling$25.06;Additions to dwelling$25: 0, _ 5Z ta dug 0 Swimming pool$25.00,Accessory bu W IV i I't1f1C$C�O€�O ilditig��5.�0,.Addition's to accessory „iidit,g�� CB � wo_�. Occupancy oft pre- sting E!Widingg- $100.0o 0 (`Dpy of Certificate of occupancy-$25 • Updated Certificate of Occupancy- $56.Ot1 Te*Porary Certificate of Occupancy Residential$15.00,Cone vial$15.00 Date. /V 71; ;z90 T cuastri,et,on: 01d or Pre-existing Building: t/r ._(check one) ( %4W )n ofProperty; 350 •4-AV-Af L ' 4.1*i' .LAeA Rouse No. ' Street . Hamlet • or Owners of Pro d7. 4) CountyT4 Map No 1000,Section Black (� 0 .,`Lot b. : 0 I q Sion. 'Filed M=, Let. so. Iq q 4 Date of Permit, q Applicant: ` l )ept.Approvak Approval: Underwriters. . Board Approval: for: Temporary Certificate Filml Certiixeaw: _ (check one) nitted:$ o_J'�� 0 0 (kc, l '� licantt S' n tore To/To 39Vd N3I890 EZ1886ZT69 ZT:ZZ 90oZ/90/bo SUFFOLK. BUREAU of L ECTPiCP,L INSPECT6PS, nc. 40 Nottingham Drive,Middle Island, NY 11963 Telephone:631 495 8136 • Fax:631 980 6455 • E-Mail:SBEIGS@gmail.com l CERTIFICATE OF ELECTRICAL COMPLIANCE i ! i Applicant: Green Logic Certificate No.: 11277 I { Rough In Inspection Date: September 30 ,2009 Final Inspection Date: September 30,2009 j Application No.: 11277 Building Permit No.: 34992 d LIPA Solar App No.:. - 084144 _County Tax Map No.: 473889 125 0004 024.019 i This Certificate of Electrical Compliance is limited to the inspection and compliance of electrical equipment and/or € + work described below, installed by the applicant named above, located at the premise of and not after the final inspection date above: ' ? Owner: Sohn Obrien I j Site Location: OBrien, 350 Laurel Way, 350 Laurel Way, Laurel, NY 11948 JOwner's Address (if different): j Residential ❑Indoor ®Basement ❑Service ❑Shed ; ! Commercial 0 Outdoor ❑First Floor ❑Pool ❑Hottub ' I ❑New ❑Renovation ❑Second Floor ! [:1 Attic ❑Garage 4 Addition ❑Survey Other::photovoltaic system _............._...._............ f I INVENTORY } Single Phase Heat Duplex Recpt Ceiling Fixture HID Fixtures i .........._....- Three Phase Hot Water GFCI Recpt Wall Fixture Smoke Main Panel AC Cond Single Recpt Recessed Fixture CO Detect . . I Sub Panel AC Blower Range ' Ran a Recpt Flourescent Pumps : :.-....... Transformer Appliances Dryer Recpt Emergency; Time Clock ............ ' `::::::::::::: ._..... I Disconnect Switches Twist Lock Exit Fixtures Tvss ( I I _._...... ......_._._... GFCI Breaker Heat Pump Electric Heat Pool Luminaire Exhaust Fan ............ Other Equipment:photovoltaic system to include 24 solar panels,1 inverter,1AC&1 DC disconnect I EI IThe electrical work and/or equipment described above were inspected andJ appear to be in compliance { iwith local, state and national electrical code.requirements and this office. .j I 1 1-: Applicant: Green Logic License No.: 43858ME � .l Inspected By: Gene Surdi Date Of Certificate: Oct 07,2009 I' l !Signature: l i ITT_ .... -.--.-.._T.-•-------..��...._.. -. .. FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 34992 Z Date SEPTEMBER 11, 2009 Permission is hereby granted to: JOHN J & EILEEN O'BRIEN PO BOX 363 37So �1.7 LAUREL,NY 11948 for INSTALLATIO40F SOLAR PANELS TO AN EXISTING DWELLING AS APPLIED FOR at premises located at 350 LAUREL WAY LAUREL County Tax Map No. 473889 Section 125 Block 0004 Lot No. 024 . 019 pursuant to application dated SEPTEMBER 4 , 2009 and approved by the Building Inspector to expire on MARCH 11, 2011 . Fee $ 200 . 00 Authorized Signature ORIGINAL Rev. 5/8/02 SOUTy�Io TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: L q DATE ' . X-Q r INSPECTOR Pacifico Engineering PC Engineering Consulting PO Box 1448 Ph: 631-988-0000 Sayville, NY 11782 Fax: 631-382-8236 www.pacificoengineering.com engineer@pacificoengineering.com November 4, 2009 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Jack O'Brien 350 Laurel Way Laurel, NY 11948 1 have reviewed the solar energy system installation at the subject address. The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets the requirements of the 2007 NYS Building Code, and ASCE7-05. To my best belief and knowledge, the work in this document is accurate, conforms with the governing codes applicable at the time of submission, conforms with reasonable standards of practice, with the view to the safeguarding of life, health, property and public welfare Regards, Ralph Pacifico, PE Professional Engineer OF IyF� CO KPH Pq�,� JO 0 m 066182 O�FSS I FIELD INSPECTION REPORT DATE COMMENTS c , FOUNDATION(1ST) � y --------------- FOUNDATION (2ND) z O ROUGH FRAMING& ' H PLUMBING INSULATION PER N.Y. y STATE ENERGY CODE pp- FINAL ADDITIONAL COMMENTS O Z m i� �I 1 e ; TOWN OF SOUTHO.LD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health VA SOUTHOLD,NY 11971 4 sets of Building Plans TEL:(631)765-1802 Planning Board approval FAX:(631)765-9502 �' Survey SoutholdTown.NorthFork.net PERMIT NO. 3 fa Check v Septic Form N.Y.S.D.E.C. Trustees p pp Flood Permit Examined 20 ! Storm-Water Assessment Form Contact: Approved 20 Mail to: VZS C> YIA 3�4, Disapproved a/c 47Vt AM� 20 Phone: � f p EC� EoWE Building Inspector S EP 4 2009 APPLICATION FOR BUILDING PERMIT Date �� ,20—PAINSTRUCTIONS BLDG.DEPT. TOWN 0E.M 'cation MUS be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Pennit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Signafore of applic t or 3 e�if c;rp uu k I U (Mailing (dress of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder C" (LC�7 S✓ Name of owner of premises � (As on the tax roll or latest deed) If applic a co ion,signature of duly authorized officer (Name itle of dorporate officer) Builders License No. t{0 of a.4- R Plumbers License No. Electricians License No. rh Other Trade's License No. 1. Location of land on which proposed work will be done: 35 a l_(I iAKQ J \AYI L_(uA el House Number Street Hamlet I I County Tax Map No. 1000 Section 10 Block b N Lot o�"I• �� Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy fe s (l6i" (M-AAAnUm b. Intended use and occupancy VA44 s 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work skall ad �D (Description) 17 4. Estimated Cost c2/a gay• Fee —� (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. A.IA- zt 7. Dimensions of existing structures,if any:Front Rear Z Depth 7 S Height Number of Stories Ciro a/frrc"Ze7l.) Dimensions of same structure with alterations or additions: Front 464 Rear Depth Height A Number of Stories 8. Dimensions of entire new construction:Front /I Rear Depth Height Number of Stories 9. Size of lot:Front "/ Rear -a(oj Depth 10.Date of Purchase 4� Name of Former Owner ["CU&yweA f!'t• S//pp �'�� 11.Zone or use district in which premises are situated $1 0e, 12.Does proposed construction violate any zoning law,ordinance or regulation?YES_NO 13.Will lot be re-graded?YES_NO Will excess fill be removed from premises?YES NO— !,.so LAAA-M W-&".r 631- 29 9'- 14.Names of Owner of premises 6IR W iMV,9, Address L OAA4 J ,Md Phone No. g/23 Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO y *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland?*YES NO— *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. .17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO *IF YES,PROVIDE A COPY. STATE OF NEW YORK) `- COUNTY 0 SilC •r (l,((11rL Q I" being duly sworn,deposes and says that(s)he is the applicant (Name of individM signing contract))above named, �z 0 (S)He is the C aY �A �t c L-C �o 0 Y m (Contractor,Agent,Corporate Officer,etc.) m�� CL W of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; Q y)U u) c that all statements contained in this application are true to the best of his knowledge and belief;and that•the work will be < r- a performed in the manner set forth in the application filed therewith. M o:� Sworn to before me this q I�Z 's day off 20 O < Notary PuAic Sign Ap li ant LIP ® �Z. - ,.. � I TOWN OF SOUTH.OLD PROPERTY RECORD CARD OWNER STREET VILLAGE DIST. SUB. LOT ACR. r EMARKS 1) Z-�l p TYPE OF BLD. / ppt) PROP. CLAS L ►n k--S L-�"C Z $PA --'2 8839 sin 1e fAmdul cJ wc)?J i'y'-� Zl z LAND IMP. TOTAL DATE Z coo 4 30 16 90o j 2 5 2" M 5 600 90 �sooZzVos ---_-- o My 1 S�oa z o LZ ld FRONTAGE ON WATER TILLABLE FRONTAGE ON ROAD WOODLAND DEPTH MEAD.OWLAND BULKHEAD HOUSE/LOT TOTAL ■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■ r � �f ,a•r era■■■■■■���■■■■■■■■■■■■■■�■ ■■■■■�■■■■■Gran r�i�l■■■■■■■■■■■■■■■■ I_ • rr, ! ao Town of Souttold � Erosion, Sedimentation & Sion-Water Run-off AS. SESSMEMT.FORM PROPERTY LOCATION s. T.fa s: THE FOLLOWING ACTIONS MAY REQUIRE THE SUBMISSION OF A STo ATER,GRADING DRAINAGE AND EItOS10N NTROL p DleWet SeaUon Block Lot CERTIFIED BY A DESIGN PROFESSIONAL IN THE STATE OWNEIN YO —— — Rom Number: (NOTE: A Check Mark(,I)for each Question Is Required for a Complete Application — y — — Yes No — — Will this Project Retain All Storn-Water Run-Off Generated by a Two(2")Inch Rainfall on Site? (�—— (This item will include all rm-off created by site clearing and/or construction activities as well as all Site Improvements and the permanent creation of impervious surfaces.) 2 Does the Site Plan and/or Survey Show All Proposed Drainage Structures Indicating Size&Location? This Item shall Include all Proposed Grade Changes and Slopes Controlling Surface WaterFlowl $ Will this Project Require any Land Filling,Grading or Excavation where there Is a change to the Natural El ✓ Existing Grade involving more than 200 Cubic Yards of Naterial within any Parcel? • 4 Will this Application Require Land Disturbing Activities Encompassing an Area In Excess of Five Thousand(5,000)Square Feet of Ground Surface? u Ij Is there a Natural Water Course Running through the Site? Is this Project within the Trustees jurisdiction or within One Hundred(I OOP)feet.of a Welland or Beach? 6 Will there be Site preparation on Existing Grade Slopes which Exceed Fifteen(15)feet of Vertical Rise to ❑ One Hundred(1001)of Horizontal Distance? M 7 Will Driveways,Parking Areas or other Impervious Surfaces be Sloped to Direct Stomt-Water Run-Offinto and/or in the direction of a Town right-of-way? _ 8 Will this Project Require the Piacement of Material;Removal of Vegetation and/or the Construction of ❑ any Item Within the Town Aigh(-of-Way or Road Shoulder Area? _. (This item will NOT Include the Installation of Driveway Aprons.) 9 Will this Project Require Site Preparation within the One Hundred(100)Year Floodplaln of any Watercourse? — NOTE: If Any Answer to Questions One through Nine Is Answered with a Check Mark in the Box, a Storm Water,Grading, —— Drainage&Erosion Control Plan is Required and Must be Submitted for Review Prior to Issuance of Any Building Permiti EXEMPTION: -------------------- AM NO Does this project meet the minimum standards for classification as,an Agricultural Project? Note: If You Answered Yes to this Question,a Storm-Water,Grading,Drainage&Erosion Control Plan is NOT Required! T ---------------------------•— STATE OF NEW YORK,couNI OF.......SK&L ............SS That I...................U c.....//L ��• •be being swon,depos es and says that he/she is the applicattt for Permit; (Name of ardivldual elgrdng Document) And that he/she is the ......................( eta)...... ....................................................... Owner and/or representative of the Owner of Owner's,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his knowledge and belief,and that the work will be performed in the manner set forth in the application filed herewith. Sworn to before me this; 4u ......... ...�........................day of Cl St............ ,.2Q. iq NotaryPublic: .............. ................................................. ............ .......... .0�.r..2...... (Signa of t) /r FORM - 06/07 Notary)ob09-State f New York - - 69 _........... _. Qualifi+ell...iR.Sti##elk-County--------.- — — ........_...... ..................................... . ............................--................... .............................--........... My Commission Expires May 11,0�1 f SCDHS• R EF* # R 10. '' 02 - 0177 " '7 i"il v' vv LOT 1 z 30.3 <1 _.. �ACA"t 3I.7 C; _ 1 renar � �r E �c t cGr 30.2 5e - T E)U11ding 94. ��. /_42 0 aor e SURVEY OF PROPER T Y ° 2-9 , 0o. A T IAA T TI TUCK 0 TOWN OF SOUTHOLD �° SUFFOLK COUNTY, N. Y. \ -s�yoG j �g �o��' a=w o� 1000 - 125 - 04 - 24.19 o \ s� =2 �� SCALE.- 1 = 30 o f l z R. R 0w C JUL Y 17, 2002 JUL.Y 24, 2002 (P1-i' hs r �� ^I DEC. l8, 2002 (STK. HSE.) Z �� !o MA Y i, 2003 ( foundation loc. 1 `\ .11 MARCH 15,.2004 l FINAL 1 .\\ C01 wnrp PORCH - (C�) The locations of wells and cesspools aQ shown hereon are from field observations v and or frc,r data obtained from others. CERTIFIET TO: JOHN J. O'BRIEN NO TE= EILEEN P. O BRIEN C` _ LOT 'iUMBERS REFER TO MI ' OF • i A UREL *LINKS" FILED IN THE O SUFFOLK COUNTY CLERK'S OFFICE AREA = 31,299 sq. ft. n�` ON NOV. 23, 2001 AS FILE NO. 10712 <. �iE O k ANY AL TERA TION OR ADDITION TO THIS SURVEY IS A VIOLA TION 256+ C.), c T. OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. •S / am /amiliar with the STANDARDS FOR APPROVAL 0� ':w EXCEPT AS PER SECTIOW 7209 - SLVDIVWON 2. ALL CERTi(FICATiONS `� �m AND CONSTRUCTION OF SUBSURFACE SEWAGE HEREON ARE VALID FOR THIS MAP AND COPIES THEREOF ONLY F DISPOSAL SYSTEMS FOR SINGLE FAMILY RESIDENCES y�' SAID MAf OR CAPES BEAR TINE'"PRESSED SEAL OF THE SURVEYOR s�f L 0. 49618 WHO,�'E SIGNATURE APPEARS HEREOM and will abide by the conditions set forth therein and on the' AODI TIONALL Y TO COWL Y WITH `'A,D permit to construct.LAW TERM 'AL TERED BY ' ECONIC S Y C. I MUST BE USED BY ANY AAD ALL SURVEYORS UTLIZJNG A COPY (63I1 765 - F (6 65 - 1797 OF ANOTHER SURVEYOR'S MAP. TEAWS SUC1'/ 'WSPECTED 'AND P. O. BOX 9 p +� BROUGHT - TO - DATE ' ARE NOT IV COMPLIANCE W/T71 THE LAW. 1230 TRAVEL SOUTHOLD, N.Y. l Pacifico Engineering PC Aft. Engineering Consulting PO Box 1448 Ph: 631-988-0000 Sayville, NY 11782 Fax: 631-382-8236 www.pacificoengineering.com 199 engineer@pacificoengineering.com September 1, 2009 Town of Southold Building Department APPROVED AS NOTED 54375 Route 25, P.O. Box 1179 Southold, NY 11971 DATE: �� 9_ f .P.# 3 Subject: Solar Energy Installation for F`�E: Jack O'Brien N,-1; I:Y BUILLDII,iG _:_.: r`.R PENT AT 350 Laurel Way 76 802 8 Ai1! TC> << IM FOR THE Laurel, NY 11948 FO,.:_^bl'ING IPJcPE iG?�S: 1. ":RATION - "-'dam REWRED 2. R^;IGH - Fi=,hP• NG' n. PLUMBING 3. LATi�i••? 4. FINAL - : CPdSl UC T ION MUST ALL CONSTRUCTION SHALL MEET THE I have reviewed the roofing structure at the subject address. of the roof mounted system. The units are to be installed in accoi&hlceMtflflfhelM, 5n!i)W(Aie'QSM ion instructions. I have determined that the installation will meet tf C riffierQt§,'68IM>✓0'O NT-MSFMt Oing Code, and ASCE7-05 when installed in accordance with the manufacturer's instructions. Roof Section A B CCUPANC'tr OR mean roof height 25 ft 25 ft pitch 7 5/8 in/12 7 5/8 in/12 USE IS UNLAWFUL roof rafter 2x10 2x10 rafter spacing 16 in OC 16 in OC `,jVITHOUT CERTIFIC,1 E Reflected roof rafter span 19.2 ft 9.2 ft � �� k'At +; It /,�/ Table R802.5.1(1) max 20.6 ft 20.6 ft �'.. C U"i� I I C 1 collar tie 2x8 2x8 collar tie spacing 16 in OC 16 in OC The climactic and load information is below: CLIMACTIC AND Wind Live load, point GEOGRAPHIC DESIGN Category Speed,3 pnet30 per pullout Fastener type CRITERIA sec gust, ASCE 7, load,lb mph psf Roof Section A B 120 26 267 5/16"dia screw, 4" length, 2 per B 26 137 5/16"dia screw, 4" length, 2 per 14 P4c�l0 ALL CONSTBUCTION SHALL_ EET THE REQUIREMENTS OF CODES OF NEW YORK STAT". Q Ralph Pacifico, PE c�QA o UND�RWRITERSCERTIFICATE Professional Engineer 86 REQUIRED 9��FSSI0 P�� S1 �; — ---i 4.05 kW G EE F-OGIC GY, SunPower225w *Z Pacifico Engineering PC UniRac Sunframe PO Box 1448,Sayville,NY 11782 Green Logic, LLC Proposed Azimuth = 212' 631-988-0000 www.oacificoengineering.com O'Brien, Jack 5.4kW PV Pitch = 32.5° Ralph Pacifico, PE NYS License 066182 350 Laurel Way Scale 3/16" = 1.0' Laurel, NY 11948 631.298.8123 pill , , � OF. , ®�ta2 ; , , , 16 High Chimney gum SunPower 225w 2x10" Douglas Fir Pane Dimension nsion = 31.42" x 61.39" Rafter 16" on center e Array Length = 157.1" UniRac SunFrame Rail Array Height = 250.81" Magic# = 62.14" UniRac L-Foot Layout Created By: BCA Date: 8/19/2009 _ S1 4.05 kW G'`EEN LOGIC; SunPower 225w �r:EPGY� UniRac Sunframe GreenLo Ic, LLC Proposed '� Pacifico Engineering PC 9 p Azimuth = 212° Fo Box -0000sayw. NY11782 O'Brien, Jack 5.4kW PV Pitch = 32.5° ss1-ses0000 wwoacificoengineering.com 350 Laurel Way Scale 3/16" = 1.0' Ralph Pacifico, PE NYS License 066182 Laurel, NY 11948 631.298.8123 pF NE�Y ZA s Zt1►�Q V�t� " S$% 15" 111MINININININIM111 hi ney iiiiMIMIMre SunPower 225w Ell 2x10" Douglas Fir Panel Dimension 31.42 x 6 1.39" - Rafter 16" on center Array Length = 157.1" UniRac SunFrame Rail Array Height = 250.81" Magic# = 62.14" o UniRac L-Foot Layout Created By: BCA Date: 8/19/2009 S2 1.35kW �: REENLOGIG SunPower 225w UniRac Sunframe fta Pacifico Engineering PC GreenLogic, LLC Proposed Azimuth = 2120 PO Box 1448,Sayville,NY 11782 O'Brien, Jack 5.4kW PV 631-988-0000 www.pacificoenoineering.com 350 Laurel Way Pitch = 32_5° Ralph Pacifico, PE NYS License 066182 Scale 3/16 - 1.0 Laurel, NY 11948 631.298.8123 4 A aw.���,.�x NV ;c vw�■rMrs�s PACia war rM.lm�vv�M� 'w FRE FREE'&■�■■vr {n� ' AU v F1M r M■■lN tit CMG.. NNIADU M HIB w�M g2a Z / !MM■ M■■M! rMM■M■MM!■M N!■■M M■MMMF ,M ■!M M■■MMr www.w M�.ara.. ■!M!■MMMYI MM■■MMMMr■s M■■M■■!■.H65Y ■vvvvM■M■vw ■M■■EM■M■■■ ■————————-C. SunPower225w Panel Dimension = 61.39 x 31.42" 2x10" Douglas Fir Array Length = 163.75" Rafter 16" on center Array Height = 195.27" UniRac SunFrame Rail Magic# = 32.17" � UniRac L-Foot Layout Created By: JPHS Date: 5/20/2009 _ S2 "� REENLOGIC! 1.35kW t , SunPower225w LLC Proposed UniRac Sunframe Pacifico Engineering PC Green Logic, p Azimuth = 212' PO Box 1448,Sayville,NY 11782 O'Brien, Jack 5.4kW PV Pitch = 32.5° 631-988-0000 www.oacifiicoengineering.com 350 Laurel Way Scale 3/16„ _ 1.0 Ralph Pacifico, PE NYS License 066182 - Laurel, NY 11948 631.298.8123 if NE eN PAc/,c 0.9� � � w /oq E S►�N'� 00 SunPower 225w Panel Dimension = 61.39 x 31.42" 2x10" Douglas Fir Array Length - 163.75" Rafter 16" on center Array Height = 195.27" UniRac SunFrame Rail Magic# = 32.17" � UniRac L-Foot Layout Created By: BCA Date: 8/18/2009 GREENLOGIC® ENERGY October 29, 2009 The Town Of Southold Office of the Building Inspector Town Hall Southold NY 11971 Building Permit#34992 To the Building Inspector: Enclosed please find the original Electrical Certificate for John and Eileen O'Brien's solar installation. We have already requested a building inspection,which your office has scheduled for November 2. We are in the process of obtaining a final engineer's report and we will forward it to you office once we receive it. Once you have inspected the solar system and received the engineer's report,please close out the O'Brien's building permit and send them a certificate of-occupancy. Please let me know if you have any questions about the installation or if there are any problems with issuing the c of o. Sincerely, Alexandra McNear Senior Account Manager [E631-771-5152 (ext.,107) D G E N E NOV 2 2009 BLDG.`DEPL TOWN OF SOUTHOLD ' GREENLOGIC, LLC m www.G reen Logic,com SOUTHAMPTON/CORPORATE SOUTHOLD MANORVILLE ROSLYN HEIGHTS 425 County Rd.39A,#101 52875 Main Rd., Box 435 40 Woodland Avenue 200 S. Service Rd.,#108 Southampton, NY 1-1968 Southold, NY 11971 Manorville, NY 11949 Rosyln Heights, NY 11577 Tel: 631.771.5152 Tel: 631.765.0404 Tel: 631.771.5152 Tel: 516.625.6880 Fax 631.771.5156 Fax: 631.771.5156 Fax: 631.771.5156 Fax: 516.625.6881 GREENLOGIC® ENERGY August 25,2009 Town of Southold Building Department Town Hall 53095 Route 25 Southold,NY 11971 Dear Building Inspector: Please find attached a building permit application on behalf of John O'Brien who has engaged us to install a roof-mounted(flat to the roof) solar photovoltaic(PV) electric system for her home on 350 Laurel Way in Laurel,NY. In connection with this application,please find attached: • A building Permit application • A Storm Water Assessment Run-off Form • Survey of Premises • Two Engineer's Reports (1 original and 1 copy) • " A One Line Diagram • A Visio Diagram of the proposed system • Spec. sheets of the solar panels (SunPower SPR-225-Wht) • Spec. sheets of the inverter(SunPower SPR 5000m) • GreenLogic Suffolk County Home Improvement License • GreenLogic'Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • . Installation Manager's Master Electrician's License Please let us know if you need anything else in connection with this application. Yours y, Alexandra McNear Senior Account Manager GreenLogic Energy GREENLOGIC, LLC. www.GreenLogic.com SOUTHAM PTO N/CORPORATE SOUTHOLD MANORVILLE ROSLYN HEIGHTS 425 County Rd.39A,#101 52875 Main Rd.,Box 435 40 Woodland Avenue 200 S. Service Rd.,#108 Southampton, NY 11968 Southold, NY 11971 Manorville, NY 11949 Rosyln Heights, NY 11577 Tel: 631.771.5152 Tel: 631.765.0404 Tel: 631.771.5152 Tel: 516.625.6880 Fax 631.771.5156 Fax: 631.771.5156 Fax: 631.771.5156 Fax: 516.625.6881 i S U N ROWE R 5000m, 6000m & 7000m INVERTERS EXCEPTIONAL RELIABILITY AND PERFORMANCE Electrical pate SPRm Efficiency Curves -SPR-5000m SPR-6000m SPR-7000m 100 I I I I I 95 250-Vdl -'- — -- AC Power 5000 W 6000 W 7000 W 90 31oydf_I AC Max Output 48o Vde I� { �P I I� Current(@208V, 24A,20.8A,18A 29A,25A,21.6A 34A,29A,25.3A •D 85 240V,277V): W so .183-229V@208VAC 183-229 V @ 208 VAC 183-229V@208VAC 75 AC Nominal 211-264 V @ 240 VAC 211-264 V @ 240 VAC 211-264 V @ 240 VAC Voltage Range 244-305V@277VAC 244-305V@277.VAC 244-305V@277VAC 70 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 60 Hz/59.3 Hz- 60 Hz/59.3 Hz- 60 Hz/59.3 Hz- %of Rated Output Power AC Freq/Range 60.5 Hz 60.5 Hz 60.5 Hz Power Factor 1 1 1 Mechanical Data Shipping Dimensions W x H x D inches 23.5"x 31.0"x 16 V Peak Inverter 96.8% 07.0% 97.1 Efficiency Unit Dimensions W x H x D inches 18.4"x 24.1"x 9.5" 95.5%@ 208 V 95.5%@ 208 V 96.0%@ 208 V Inverter Weight 143 Ibs CEC Weighted 95.5%@ 240 V 95.5%@ 240 V 96.0%@ 240 V Efficiency Shipping Weight 154 Ibs cY 95.5%@ 277 V 96.*0%@ 277 V 96.0%@ 240V Cooling Forced Air/Sealed Electronics Recommended Cooling Array Input Power 5300 W 6400 W 7500 W Enclosure NEMA 3(DC @ STC) R Mounting Wall Mount Bracket Standard DC Input 250-600 V 250-600 v 250-600 V Ambient Temperature Range -13 to*113°F Voltage Range Peak Power Wty d Certifications 250-480 V 250-480 V 250-480 V arran an Tracking Voltage Warranty 10 year limited warranty DC Max. 21 A 25 A 30 A Certifications Compliance:IEEE-929,IEEE-1547,UL 1741-2005, Input Current UL 1998,FCC Part 15 A&B DC Voltage 8]9 967 <5% Ripple No.of Fused 4 String Inputs Power Consume: / <7 w/0.25 w Standby _ Nighttime Fused DC&AC Standard;Complies with NEC Standards Disconnect Grounding Positive Ground About SunPower SunPower designs, manufactures and delivers high-performance solar electric technology worldwide.,Our high-efficiency solar cells generate up to 50 percent more power than conventional.solar cells.Our high-performance solar panels, roof tiles and trackers deliver significantly more energy than competing systems. C June 2007 SunPower Corporation.All rights reserved.Specifications included in this datasheet are subject to change without entice. Document 11001-16967 Rev" www.sunpowercorp.com h 5000m, 6000m & 7O00m INVERTERS EXCEPTIONAL RELIABILITY AND PERFORMANCE BENEFITS Reliable and Robust Design Proven track record for durability w, and longevity Effective Power Range Enables most systems to use a single inverter rather than multiple units Commercial Use Flexible AC voltage output and scalable building blocks create an easy solution for commercial applications High Efficiency Weighted CEC efficiency over - 95.5% and peak efficiency over 97% Reduced Installation Cost Integrated AC-DC disconnect with fuses I I lowers material costs and �- labor requirements 0) Attractive Aesthetics Integrated disconnect eliminates need for visible conduits to inverter The SunPower inverters 5000m, 6000m & 7000m provide exceptional reliability and market-leading design flexibility. The SPRm line of Solar Inverters can be easily applied in residential or commercial installations. All models come with a 10-year warranty. w - SPR-5000m, SPR-6000m & SPR-7000m www.sunpowercorp.com r i I � S U N POWE R 225 SOLAR PANEL EXCEPTIONAL EFFICIENCY AND APPEARANCE BENEFITS Highest Efficiency Panel efficiency of 18.1% is the highest commercially available for residential applications Attractive Design Unique design combines high efficiency and an elegant, all-black appearance More Power Delivers up to 50% more power per unit area than conventional solar panels Reliable and Robust Design Proven materials, tempered front glass, and a sturdy anodized frame allow panel to operate reliably in multiple mounting configurations The SunPower 225 Solar Panel provides a revolutionary combination of high efficiency and attractive, uniform appearance. Utilizing 72 next generation SunPower all- back contact solar cells and an all-black backsheet, the SunPower 225 elegantly delivers an unprecedented total _ panel conversion efficiency of 18.1%. The panel's reduced voltage-temperature coefficient and exceptional low-light — performance attributes provide far higher energy delivery per peak power than conventional panels. Va I -- SunPower's High Efficiency Advantage-up to 50%More Power I � ' �. __ Y Comparable systems covering 25 m2/270 W 1 _ Conventional SunPower Watts/Panel 165 225 Efficiency 12.0% 18.1% kWs 3.0 4.5 SPR-225-BLK r��F C E c&s • 225 SOLAR PANEL EXCEPTIONAL EFFICIENCY AND APPEARANCE Electrical Data IV Curve Measured a151andard Test Conditions(STC1:irrodiance of 1000/m',air mass 1.5g,and ceR kmparalu�e 25'C -- - Peak Power(+/-5% Pmax 225 W 7.0) • , Rated Voltage Vmp 41.0 V 6.0 5.0 loon W/m= Rated Current Imp 5.49 A a 4.0 a�W/'"' Open Circuit Voltage Voc 48.5 V Short Circuit Current Isc 5.87 A t 3.0 500 W/m2 Maximum System Voltage IEC,UL 1000 V,600 V v 2.0 51 Temperature Coefficients 1.0 1000 W/mz at 50'c Power -0.38%/°C 0.0 - `- Voltage(Voc) -132.5 mV/°C 0 10 20 30 40 50 60 Current(Isc) 3.5 mA/°C Voltage(V) Series Fuse Rating 20 A Current/voltage characteristics with dependence on irradiance and module4emperature. Peak Power per Unit Area 181 W/m2,16.8 W/ft2 jWNNKTeWsWW Operating Conditions CEC PTC Rating 207.1 W Temperature -40a C to+90°C(-40°F to+194'F) Max load 50 psf(2400 pascals)front and back Mechanical Data Impact Resistance Hail—25mm(1 in)at 23 m/s(52 mph) Solar Cells 72 SunPower all-back contact monocrystalline Front Glass 3.2 mm(1/8 in) tempered Warranty and Certifications Junction Box IP-65 rated with 3 bypass diodes Warranty 25 year limited power warranty Output Cables 900mm length cable/MultiContact connectors 10 year limited product warranty Frame Anodized aluminum alloy type 6063 Certifications IEC 61215,Safety tested IEC 61730 Weight 15 kg,33 Ibs UL listed(UL 1703),Class C Fire Rating Dimensions lee , 1200 —� e4.21.16) If n.041 147.24) ICwwdl 2C 04.2 (.161 I c+sad) k rti 754 79e 129.69) 31.42i 915 322 1559 p 0 (zb) 136.021 (1269 J (01.39) pe [16) l6 (a—A) CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT.Go to www.sunpowercorp.com/panels for details About SunPower SunPower designs,manufactures and delivers high-performance solar electric technology worldwide.Our high-efficiency solar cells generate up to 50 percent more power than conventional solar cells.Our high-performance solar panels,roof tiles and trackers deliver significantly more energy than competing systems. ®October 2007 SunPower Corporation.All rights reserved.Specifications Inducted in this datasheet are subject to change without notice. Document#00142188 Rev" Printed on recycled a C�1 �ced paper r p p www.sunpowercorp.com I I • 225 SOLAR PANEL EXCEPTIONAL EFFICIENCY AND APPEARANCE Electrical Data IV Curve Measurd d Slalsdard TW Eood7ians(STCI:iradiance of 1 /m2,air mass 1.Sg,and cel hmporatun25'C 000 . 7.0 Peak Power(+/-5%) Pmax 225 W .0 Rated Voltage Vmp 41.0 V 5.0 1000 W/m2 Rated Current Imp 5.49 A Q 4.0 800 W/111112 Open Circuit Voltage Voc 48.5 V Short Circuit Current Isc 5.87 A t 3.0 - V 2.� 500 W/m2 Maximum System Voltage IEC,UL 1000 V,600 V Temperature Coefficients 1.0nl 0 0 0.0 _ _- _ Power -0.38/a/C -- Voltage(Voc) 7132.5 mV/°C 0 10 20 30 40 50 60 Voltage M Current(Isc) 3.5 mA/°C Series Fuse Rating 20 A Current/voltage characteristics with dependence an irradiance and moduleiemperature. Peak Power per Unit Area 181 W/m2, 16.8 WA2 Tested Operating Conditions CEC PTC Rating 207.1 W Temperature —40°C to+90°C(-40°F to+194°F) Max load 50 psf(2400 pascals)front and back Mechanical Data Impact.Resistance Hail—25mm(1 in)at 23 m/s(52 mph) Solar Cells 72 SunPower all-back contact monocrystalline Front Glass 3.2 mm(1/B in) tempered Warranty and Certifications Junction Box IP-65 rated with 3 bypass diodes Warranty 25 year limited power warranty Output Cables 900mm length cable/MultiContact connectors 10 year limited product warranty Frame Anodized aluminum alloy type 6063 Certifications IEC 61215,Safety tested IEC 61730 Weight 15 kg,33 Ibs UL listed(UL 1703),Class C Fire Rating Dimensions mm C0t 180 r 1200 04.2 4161(7.061 (47.24) f G-rd) 2x a(.14.2 61 (G010d) 754 798 129.691 131.42) 915 322 1559 pet) 042(.I61 SI06.6(Y6) p6.a-0 112.69) (61.39) I1 CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT.Go to www.sunpowercorp.com/panels for details About SunPower SunPower designs, manufactures and delivers high-performance solar electric technology worldwide.Our high-efficiency solar cells generate up to 50 percent more power than conventional solar cells.Our high-performance solar panels,roof tiles and 0ackers deliver significantly more energy than competing systems. ®October 2007 SunPower Corporation.All rights reserved.Spec1(ications included in this datasheet are subject to change without notice. Document N001-42188 Rev•• `� Printed on recycled paper www.sunpowercorp.com SUNPOWER 225 SOLAR PANEL EXCEPTIONAL EFFICIENCY AND APPEARANCE BENEFITS Highest Efficiency Panel efficiency of 18.1% is the highest commercially available for residential applications Attractive Design Unique design combines high efficiency and an elegant, all-black appearance More Power Delivers up to 50% more power per unit area than conventional solar panels Reliable and Robust Design Proven materials, tempered front glass, and a sturdy anodized frame allow panel to operate reliably in multiple mounting configurations The SunPower 225 Solar Panel provides a revolutionary combination of high efficiency and attractive, uniform appearance. Utilizing 72 next generation SunPower all- back contact solar cells and an all-black backsheet, the SunPower 225 elegantly delivers an unprecedented total panel conversion efficiency of 18.1%. The panel's reduced voltage-temperature coefficient and exceptional low-light -- ----- performance attributes provide far higher energy delivery per peak power than conventional panels. II SunPower's High Efficiency Advantage- up to 50%More Power Comparable systems covering 25 mz/270 W Conventional SunPower Watts/Panel 165 225 Efficiency 12.0% 18.1% Ws 3.0 4.5 SPR-225-BLK a. � 3 Strings of 8 SunPower 225 W John O'Brien panels, 350 laurel Way Each string 1800 watts Laurel, NY Array total of 5400 Watts 24 SunPower 2�25 watt panels All panels to be grounded as per NEC code 2,30 AMP two pole DC switches from panels to inverter F F F O O O SUNPOWER SPR 6000 INVERTER 240 VAC 240 VAC from inverter to a 30 Amp switch near utility meter