Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
34154-Z
FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall. Southold, N.Y. CERTIFICATE, OF OCCUPANCY No: Z-33733 Date: 05/22/09 THIS CERTIFIES that the building ALTERATION Location of Property: 2595 WESTPHALIA.RD MATTITUCK (HOUSE NO. ) (STREET) (HAMLET) County Tax Map No_ 473889 .Section 114 Block 10 Lot 22 Subdivision Filed Map No_ Lot No_ conforms 'substantially to the Application for Building Permit heretofore' . filed in this office dated SEPTEMBER 10, 2008 pursuant to which Building Permit No. 34154-Z dated SEPTEMBER 12, 2008 was i.ssued, and conforms to all of the requirements of the applicable provisions of the law, The occupancy for which this certificate, is issued is BASEMENT ENTRANCE AND BILCO DOOR ADDITION TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to JAMES R SR & SHARON L COX (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE NO_ N/A PLUMBERS CERTIFICATION DATED' N/A . 1 ' Authorized Signature Rev. 1/81 Ib l�J ,� V• Form No.6. TOWN-OF SOUTHOLD ,BUILDING,D]PARTMENT MAY 2 0 2009 TO.'"HALL '765-1802 BLDG.DEFT. APPLI ATION.FOR CERTIFICATE OF OCCUPANCY. TOwN Of SOUTHOLD This.application must.be filled in by typewriter or ink and submitted to the.Building.Department with the following: . A. For new building or•new.use: 1. . Final survey of property with.accurate location of all buildings,property lines`;.streets,and unusual natural or topographic features:. 2: Final Approval from Health Dept.of water:suppty and sewerage=disposal:(S-9 form). 3.' Approval of electrical installation from Board of Fire Underwriters. 4.. Sworn."statement from plumber certifying that°the solder tiled in system contains less than 2/10.of 1%:lead 5. :Commercial'Building,industrial building;multiple.residences and similar buildings and installations;.a certificate . of Code Compliance.finni architect.or engineer responsible-for.the building.. .. 6. Submit PlanningBoard.A royal of com leted site plan r. uueinents:. . pP P P eq .. :. B. For existing Buildings.(prior to April 9- 1957)non-conforming.uses;or buildings.and"pre existing".land•uses; 1. Accurate survey of property.showing alI property.lines, streets,.building and unusual natural or topographic features. _ 2: 'A-properly:completed:applie4tion.,*and consent to inspect.signed by the''applicant.If a Certificate.of Occupancy.is ddiied;,the Building.Inspector sliall'.state the reasons therefor in writing to:the:applicant. Cs-• Fees L . Certificate:of Occupancy-New dwelling$25;00i Additions to dwelling:$25.00,Alterations to dwelling$25.00' swimming pool$25m,Accessory building$25.00,Additions to accessory building$25.00,Businesses$50.00.' 2: Certificate of.Occupaacy.ori'Pre-existing Building-. $100.00 3.. Co' -of Cerdficate,o£Occupancy=.$:25 4. Updated Certificate of Occupancy $50:0,0 5- Temporary.Cei-t at of Occupancy-Residential.$15.00,Cominercial$15.00 . Date. New:Construction: .� - Old or Pre-existing Building:. (check one) ; Location of Property.: g q g W SZSA�j 1 Ol R� ' House No, . Street Hamlet. Owner or Owners,of Property: .Suffolk CountyTax Map-No-1000:Section P � 1�. ��.. Block: .. Subdivision Filed Map.- . ,Lot: Permit-No.\ �-IS 'Date of Perinit. Applicant:_ Health Dept..Approval: . Underwriters Approval: • Planning Board Approval: R Request for:; Teinporary,✓Certficate Final.Certificate: (check one) Fee Submitted: $ c9 Q G �I Applicant Signature FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 34154 Z Date SEPTEMBER 12, 2008 Permission is hereby granted to: JAMES R SR & SHARON L COX PO BOX 353 MATTITUCK,NY 11952 for BASEMENT ENTRANCE AND BILCO DOORS PER SPECS AS APPLIED FOR. at premises located at 2595 WESTPHALIA RD MATTITUCK County Tax Map No. 473889 Section 114 Block 0010 Lot No. 022 pursuant to application dated SEPTEMBER 10, 2008 and approved by the Building Inspector to expire on MARCH 12, 2010 . Fee $ 200 . 00 :r' e S nature ORIGINAL Rev. 5/8/02 OF SOUjyO�o couom,��' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: r DATE `��a / INSPECTOR COMIYIENTS FIELD INS .'ECTION REPORT DATE b FOUNDATION (1ST) -------------- -- ----------- ------ - - 3 c i FOUNDATION (2ND) \ O G ROUGH FR A IN G& PI!LTM13 NG �\ INSULATION PER N- Y. — STATE ENERGY CODE - \I FINAL I • ADDITIONAL COZYIR ENTS � z • e nz t� x � a i i f TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 i ( t�' C Survey SoutholdTown.NorthFork.net PERMIT NO. `-� l _1 Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined ,20 Storm-Water Assessment Form Contact: Approved ,2d Mail to: Disapproved a/c Phone: Expiration 20_( 9 b,.` n�"` Building Inspector APPLICATION FOR BUILDING PERMIT -~ Date �O� , 20 Q!F— ��. INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) �• J 7 (1 q T z- o'9pl&ica ` State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder n<x�7�� Name of owner of premises (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work,will be done: House Number Street Hamlet County Tax Map No. 1000 Section ! ` Block L0 Lot Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO-,,V_Will excess fill be removed from premises? YES NO Sc 14. Names of Owner of premise Address 2 `�S tJ One No.(05 Z�� 916 �- Name of Architect Address Phone No Name of Contractor e7�` /GAL Address/Ue�A Phone No.(�3 t 1 F?2 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO ` Q * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, CUIVNIE D.BUNCH S He is the Notary Public State of New York ( ) No 0l hat n� (Contractor,Agent, Corporate Officer, etc.) Qualified in Suffolk County 'ommission Expires April 14, 0-L,)_ of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me thi I day of� 20 )��, Q—C4 Notary Public Signature of Applicant TOWN OF SOUTHOLD PROPERTY RECORD CARD OWNER STREET Cq �� VILLAGE DIST. SUB. LOT FORMER OWNER ' S W TYPE OF BUILDING r ,ES.,��Q SEAS. VL. FARM COMM. CB. MISC. Mkt. Value LAND IMP. TOTAL DATE REMARKS X!6- 7161 0 0 3000 0 o z 4 aZ/ (?)Palos' BPS S e rounol �onl 5 3."2001 r iac)d cq, 5 AGE BUILDING CONDITION Cab r7 l� NEW NORMAL BELOW ABOVE 1 FARM Acre Value Per Value Acre ` I illable 1 'illable 2 'illable 3 Voodland wampl,and FRONTAGE ON WATER } rushland FRONTAGE ON ROAD louse Plot DEPTH BULKHEAD otal �` .� DOCK NOON■■ ■■■■■■■■■■■■■■■■■■■ ��- • •• NOON■■■ ■■■■■■■■■■■■■■■■■■■ ■EN■■O ONE■■■■■■■■■■■■■■■■ 5m �, .• ,, .�$yQQ� EMM■ME NONE■■■■■■■■■■■■■■■ MEMO k: ry EEO■■■■ OE■OOE' OMEN ■ENE■■ _!NEE■N■EOM■■LINO■MEN MENN ■ EANIMMME OMEN■N MEEMME■■OIMMKI MEMO MEMO --IAMB MEN v :..x - ■NON■■■ ■■NrMONE■�■■E■NN■N MEMO No N■O■■N■■■MNM ■■■ME Foundc _• Basement •• 1'34 4 I hj I �`v Lr 77 fib.$ i!1 AI4 �' •V A v} �ro' ALL CONSTRUCTION SHALL �' MEET THE REQUIREMENTS OF THE <ti. CODES OF NEW YORK STATE. V iiMW IL3 �r aaks � RETAIN STORM WATER RU 1 I� PURSUANT TO CHAPTER 2 5 i iii OF THE TOWN CODE. tz ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE a CODES OF NEW YORK STATE. OCCUPANCY OR a o �J C3 USE IS UNLAWFUL a VITHOUT CERTIFICATE GJ --- OCCUPANCY N5131pp'il!. 92 50' APPROVED AS NOTED � ,�. . PAW" B.P. DATE 'V 1' lW A0 MW FEE:--- NOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: COMPLY WITy ALL COD 1. FOUNDATION - TWO REQUIRED NEW ti'ORK � I ES OF FOR POURE'o CONCRETE AS RE �� N� & TOWN COD 2. ROUGH - FRAMIN�a & PLUMBING QI.1l, �� ES 3. INSULATION CONDITIONS OF "�SOI!THOLD TOWNZgq 4. FINAL - CONSTRUCT ION MUST BE COMPLETE FOR C.O. SOUTHOLD TOWN PLANNING BOARD, ALL CONSTRUCTION SHALL MEET THE OF NEW SOUTHOLD TOWN;TRUSTEES REQUIREMENTS OF THE CODES YORK STATE. NOT RESPO IBLE FOR N.Y.S.DEC DESIGN OR CONSTRUC ,;W ERRORS. a Manning The Basement Areaway Basement areaways can be constructed by the foundation contractor as part of the foundation or can be supplied as a prefabricated concrete casting from an authorized Bilco dealer.The following is an overview for each of these areaway construction methods. Ske B t,Az'eaw y Stair Stringer Installation Site-built areaways can be constructed at the same time as the house foundation utilizing the same type of footings and construction.Site built areaways require wooden steps to also i, raft i be built on site.Step construction can be simplified by using Bilco stair stringers. The table shown will help you determine the size to build the basement areaway.Select areaway location and determine height of grade above the finished basement floor.Find grade height in Nail steel Stair Stringers to Cut wooden treads to the first column of the table shown and determine the inside areaway sidewalls. required length and slide dimensions of areaway foundation,Bilco Door size(extension them into stringer slots. ifrequired),and Stair Stringers. DIMENSIONSAREAWAY 'BILCO DOOR EXTENSIONS:Avallable for Size C Door BUILD AREAWAY TO USETHIS STRINGER UNIT USE THESE (only),flim mdensions Increase the lenglhtorillonger HEIGHT OF GRADE THESE INSIDE BILCO DOOR HAS B-1/4"RISE, BILCO STAIR areaways.and Intalal lepFndlwhedin lour sizeo sidepleces e6.12 ABOVE FINISHED DIMENSIONS AND 8-3/8"RUN AND STRINGERS AND / and 248.Complete wilti.Fuuctions inndrequired hardwire. \L end 24'.Complete wilt instructions and required hardxmro. BASEMENT FLOOR (See Drawing Above) EXTENSION 1-1/8"NOSING EXTENSIONS (Size E Extension MULTIPLE WILL BE: Door Extension Run+in Treads In has 3-Tread Run) W EXTENSIONS: H. L W Size Size Areaway Areaway Two or mare extensions can be 24"to 31 W. 40' 44" SL None 26-1/4" 3 Not Available mounted back to ( ) �+ back.Caulk 6, 32"to 39"- 41-1/4' 40" 44" SL None 34-5/8' 4 SL between each LENGTHS extension,and caulk 40'to 47'(See Note) 49-12' 40" 44" SL None 34-58' 4 SL or Bash the jam _ 48"to 55"# 57-314' 54" 40" O None 51-318'1 6 O against the house. SG to 64"# 66' 60" 44" B None 59-3/4' 7 B STAIR STRINGER EXTENSION—SIZE E:Three •Imad' exlension bulls to bottom or standard stringer unit.Used _ 65'to 72' 74-1/4' 68' 48" C None 68-1/8' 8 C I with any size(0.B or C)Stair Stringer.Complete with 73'to 80"(See Note) 82-12' 68" 48" C None 68-1/6' 8 C HEIGHT hardware. 73"to 80" 82-12' BO" 48' C 12' 76-12' 9 O+E -\ NOTE:For basements more Than 91'tlee 81'to 88"(See Note) 90-3/4' 80' 48' C 12" .76-12" 9 O+E m LENGTH-` (finished floor to lop of foundation wall)building a bottom _ 81"to 88' 90-314" 86'4 48' C 18' 84-7/8" 10 B+E \.. WIDTH slap within the foundation wall opening(sea drawing below)is recommended.The concrete slap should 89"to 97'(See Note) 99, 86" 48' C 18" 84-7/8" 10. B+E extend 6'Into stairwell. 89'to 97' 99" 93" 48' C 24' 93.1/4" 11 C+E CAUTION:Suggested construction allows minimum of 98'to 106" 107-114" 104" 48' C 24'+12" 101-5/8" 12 C+SL 74'headroom.This is the recommended minimum. 107'to115' 115-12' 110' 48' C 24"+16" 110, 13 O+R I _ RIM+1.11a'NOSING' VERTICAL 116"to 123" 123-3/4" 116' 48" C (2)24" 118.3/8" 14 B+B DOOR 124'to 131 132' 134' 48' C (2)24'+18' 126-3/4' 15 C+B BILCO FOUNDATION- STAIR 132"to 139" 140-1/4" 140" 48' C (3)24- 135-1/8' 16 C+C STAIR WALL ( STRINGER STRINGER 140"to 148' 148-12' 146" 48' C (3)24"+8' 143-12' 17 B+B+E CONCRETE AREAWAY -- STEP FLOOR 149'l0 156' 156-3/4' 158' 48" C (3)24'+18' 151.7/8' 18 C+B+E 2'X 10• --_ /MAY BE HERE FlNISHED L 157'to 164' 165° 164" 48' C (4)24' 160.1/4' 19 C+C+E INSIDE WOOD TREADS FLooR \ r; &L4' -AREAWAY 165"to 172" 173-1/4" 176" 48' C (4)24'+12° 168-5/8' 20 C+C+SL DOOR FLooR 'Ab m Finai,ad Basement Floor t k/-House WaA&5' SS H4wirmn House Wati 69• .Rum plus 1-1/B'Nos6ig on Borlorn Tread Pre-Fabricated freeway Pe Entayo - I he Complete Basement Entrance Available through a network of specially trained and authorized dealers,the PermEntry basement access system consists of a recast concrete stairwell topped with a Bilco Basement Door—delivered Y P PP :a;t;: I. and installed on-site in just a few hours. Available in seven standard configurations,the durable PermEntry access system includes the r:l following features: q m Bilco Basement Door • Watertight areaway foundation seal © One piece precast concrete areaway construction • Professional installation by an Concrete thoroughly vibrated for maximum density authorized dealer Door Sizing FOOTING PE CASTING C DOOR(D) H(D) TO GRADE SIZE HEIGHT LENGTH WIDTH HEIGHT 35"—41" S 0 45" 511& 52" n 52"—58" O 60" 60" 511/2" 30" 59"—66" B 68" 66" 551&' 22" I-i(c) 67"—74" C 76' 74" 551N' 191/2" W(C) 75"—82" D 84" 86" 551N' 22" 83"-91" E 92'A" 953/a" 58" 22" 92"—991, F 1011, 104" 58" 22" ® D America 's Finest L LBasenient Doors • 111,1I A • lr. •.�.:.:� � ;.!.i.I.l, .i.Yi, i'.ilr:o b ,serrrc:ni doors are available in ivro laasic slyles:Steel sided doors for areaways with a level foundation (shoinm here)and boors for Sloped masonry sidewalls (see reverse side'), Poi-fora-ling the measui,erneid proc.(4dwe and choosing the correct door is easy,sirnply :'(!Iola it Ic:step:;below: _ �";'�� 1. Di;;r(:gard lY,a old door and nu:asur(-� u1 inche.: 111a dirru:nsions o1111c exislirl( `) g�w'eaway fourxfatiun. 2. di1'r1(-118iOn h1r'I,the insido wid11),arld dimr:nsiorl M';�,111e outside width of the areaway Tfound»lion. [;l 3. k�casurr>>di,oension L 1,111c:irlsidr.:k:ny111,and dimension L ,the-outside Ic:ng111 of the areaway 1. foundation. 11 4. 1%&risuro dimension H'I,file 11eighi from the top of 111c:areaway foundation to 111c:lop of the olw:rlinq �l \ VIr1..•. irl the-rlou:x:foundation. , Width LengthfHeight W2 , Record111eL2 dimensions irl Vlri-I"4"= L 1-r2"tile-spaces provided and - calculate as shown at right. VV2 = L2 = Select the door wi111 a width between VI'i 14"and 14r ,and a length bet l4,een L 1-12"and L2.Extensions are available for Size C doors to increase _- length.The Height of door should be greater than dimension H 1. Foradditional j Length with Extension Panel information ask Model Width Length Ext G" Ext 12" ExtT18" Ext 24" Height for broth re or o brochure orSize O 47" 5£3" Y. X XX 30" contact Bilco. Size B 51" 64" X H� -X XX 22"SizeC55"U 72" 78" 84" 9ZZ 6" 19-1/2" �\ Size SL 51" 43-1/4" X X X X 52" L W�. ®Foundation plates can be used to reduce the inside width of areaways wider than 55" - C:)Iwo or more extensions can be mounted together for areaway lengths greater than 96" o- �_( E [ L N L.•:.l .'^L [[ - t S v_.:b i:J.• '2i`;s ,.l?Y J r -t' y _( ( ' - ..L ...r'... T :.�,�' �, .; �. .. '.r••a- { -1,. 4(.4 IL M � few i L M" � Diu'° Keyed Lock kit: Enjoy the convenience of locking and unlocking your Bilco basement door frorn the outside.Install a Bilco keyed entry lock and save the trip into the basement 10 unlock the door.A turd of the key opens the door from the outside and a handy release lever automatically unlocks the door from the inside.The Bilco keyed entry lock is designed for installation in less than 30 minutes. F-oundation Plates: Bilco Foundation Plates are Stair Stringers: Bilco stair stringers are an economical way to add a staircase to any installed on top of areaway foundation sidewalls to: existing basement areaway. Constructed of 14-gauge galvanized steel,they will give you the Improve the appearance of old areaway foundations and same lasting service as your Bilco Door. Installation is easy, simply nail the "stringers to the sloped sidewalls areaway sidewalls,cut wood treads to required length (wood not supplied with stringers), and slip them into Cover rough masonry and small holes,and span voids in place.To determine the Stair Stringers required,mea- — brick and con- t sure the height of grade above the finished basement Crete block /�"� floor(H)and Length(L)of your areaway opening.Select !Reduce inside l �� �.--_ the proper Stair Stingers from the table below. H width of area L 1•vay rough - Select f/of L H must be at least openings to fit Stair Stringer treads ` 11 (ruin of stair stringers) l3ilco Doors. \� 32"-39" SL 34-5/8" 4 �� \ Support Bilco Model lengthF Height (. 48"-55" O 51-3/8" G doors in corner FP5 84" 1-3/4" 5G"-64" D 59-3/4" 7 irlsiallatiorls. FP8 84" 1-3l4" FP11 84" 1-3/4" 65"-72" C 68-1/8" 8 Note:Size E Stair Stringer Extensions are available toFor additional information FP14 84" 1-3/4' increase the stringer length by 3-treads. ask for 13ilco N-150 brochure or contact Bilco. ci'fc�..•�,c;•. i• •F r. ^r'v�c: "i tY r r � } t .. The Bilco Company,P.O.Box 1203.New Haven,CT 06505 tte�� Giving Basenzents Be. ®" Phone:(203)934-6363 Fax:(203)931 43G5 Website:www.bilco.com