Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
52959-Z
Town of Southold * * P.O. Box 1179 G A 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47157 Date: 06/23/2026 THIS CERTIFIES that the building EXHAUST HOOD AND/OR FIRE SUPRESSION SYSTEM Location of Property: 53930 Route 25 Southold, NY 11971 Sec/Block/Lot: 61.4-19.1 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 05/05/2026 Pursuant to which Building Permit No. 52959 and dated: 05/07/2026 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Fire suppression system to existing building as applied for. The certificate is issued to: CAST Inc Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: PLUMBERS CERTIFICATION: s� Authorized Signature �a0FS0�Tyo TOWN OF SOUTH OLD BUILDING DEPARTMENT `� • .� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52959 Date: 05/07/2026 Permission is hereby granted to: CAST Inc PO BOX 1566 Southold, NY 11971 To: Fire suppression system to existing building as applied for. Premises Located at: 53930 Route 25, Southold, NY 11971 SCTM#61.-4-19.1 Pursuant to application dated 05/05/2026 and approved by the Building Inspector. To expire on 05/06/2028. Contractors: Required Inspections: Fees: Exhaust Hood and/or Fire Suppression System $300.00 CO Commercial $100.00 Total $400.00 Building Inspector pF SO//Tyolo - * TOWN OF SbUTHOLD BUILDING DEPT. °ycoum, 631-765-1802 61 5 a95a INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING rIFINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR ���� e2•� w+n FFN TOWN OF SOUTHOLD—FIRE MARSHAL Town Hall Annex 54375 Main Road P. 0. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov FIRE PROTECTION SYSTEM PERMIT Date Received APPLICATION For Office Use Only PERMIT NO. Building Inspector: V6-es M AY 5 2026 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted.-WORK IS NOT TO BE STARTED'prior to the approval of plans and issuance of a permit. Has a building permit been obtained for this project? 0 Yes 0 No If yes,building permit# Date: PROJECT INORMATION: Project Address: 53930 SCTM# 1000- 0 6 1- City: 0 0*0 LI> W-� I vq Zip: CONTACT PERSON INFORMATION: Name: Mailing Address: ooe%�LL Afe- 9^4 514ar-e— V706 Phone#: 671i -- 316 - 4-791 Email: Preferred contact method(select one): DPhone OEmail CONTRACTOR INFORMATION: Name: , Fontractor License#: Mailing Address: 9 o0e.t-L Al --9 koiee- Ad 11-106 Phone#: 631- 'S t6 '4-19( Email: fAo L AtibeRi!�o4 r Pe--xfjcP— i--com SCOPE OF WORK: Occupancy Description: 0 Assembly WBusiness 0 Education 0 Factory/Industrial 0 Institutional 0 Mercantile 0 Residential 0 Storage Description of Work: --rij 5—%A L L A Aew v1,Too A, ONew System 0 Existing System Modification Sprinkler/Standpipe/WaterSupply Fire Alarm/CO Detection Systems Other Fire Protection Systems (Check all that apply) (Check all-that apply) (Check all that apply) 0 NFPA 13,13D or 13R System OManual DAutornatic El Smoke Control DStandpipe 0 Fire Pump OProtected Premises(local) P-Met or Dry Chemical/Clean OSupervising station Agent Number of sprinkler heads: OCentral Station 0 Kitchen hood/exhaust E] Other Floor Area(sq. ft.): l Cbeck Btix After Readings I,the undersigned;understand that the issuance of a permit for the type which is herein applied for is based on the agreement to conform to Ali regulations and requirements.I further"understand that non-compliance of said requirements,by myself or any officer or employee of the firm or individual listed,as the applicant on this form,shall.be cause for revocation of said permit.Upon revocation of said permit the applicant or any employee of the applicant shall be prohibited to conduct such work for which this permit was issued.The reissuance of a permit shall be based upon review of the circumstances leading to the revocation.Any false.statement(s)made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the Penal Law Application Submitted By(print name): T�RR�� LKuthorized Agent ❑Owner Company(if applicable): Applicant Signature: Date: -I.'7••02 .Q.6 FIRE PROTECTION SYSTEM PERMIT APPLICATION SUBMITAL INSTRUCTIONS Submit application only after reviewing the requirements for the specific permit for which you are applying(click the applicable link below). • FIRE ALARM/CARBON MONOXIDE DETECTION SYSTEM[SUBMITTAL GUIDELINES • FIRE SPRINKLER SYSTEM SUBMITTAL GUIDELINES • FIXED FIRE SUPPRESSION,HOOD&EXHAUST SYSTEMS SUBMITTAL GUIDELINES FEES A$300 permit fee is required for a non-residential permit.A$100 Certificate of Occupancy fee is required if the project is not part of an existing open building permit. All checks should be made payable to the Town of Southold. Permits,once issued,shall at all times be kept on the premises designated thereon with a copy of approved drawings and all related documentation required to obtain said permit.Installations subject to final testing,inspection and approval.Arrangements for testinglinspection shall be made by contacting the Town of Southold Building Department(631)765-1802. FOR OFFICE USE ONLY Amount Paid: CheckNo.: FM: Permit No.: Date; . Exp. Date: 2 Z m 6 APPROVED W NOTED 3 w 8'x8" DUCT HOOD SEALS (TYP.) W &In Z FIRE INSPECTION a 5'-0" HOOD ADP Xz" SPLIT TEE DATE: sl7l� B.P.# 5�q 5R o '—' REQUIRED BEF©RE _ N A! �'��11 — 4kHEAD FEE �14OU BY: W W oOPENING - 360' 360'o L — ADP NOTIFY FIRE MARSHAL AT 631-765-1802 pr, I FOR THE FOLLOWING IIVSPECTIONS: N I I 1. ROUGH INSPECTION 2. COMPLIANCE TESTING pW„ U) Additional I RANGE GUARD I I 3. FINAL INSPECTION ti z Certification I I U) ALL WORK SHALL COMPLY VOTH NYs May Be Required I I O ES AND APPLICA BLE NFPA U Q EL N ' LPR ADP I t� STANDARDS < N 0 LPR c co z RPSM -- V) Z Q 6" MIN. I PULL �V J TO EDGE OF 36"x28" _ o I STATION � HOOD ON o �" GAS I o :�.� �`+ ON:SHALt.l "` �.. TA C BOTH SIDES RANGE N VALVE �� ;\ 6 BURNERfkf AIi T:TNE REt 119 J T W/SHELF _ J CqS 0�NEW,,. TATE' o yUj rt FLOOR FRONT VIEW 0775�o SCALE:%"=1'-O" _ - N OFESS��� AES MANUFACTURER: COMPONENTS: NOTES: oz Z RANGE GUARD: _RG 1.25 GAL. _RG 2.5 GAL. _RG 4 GAL. RG 6 GAL. x Fryers to have High Limit Control to shut off fuel at 425'. o o0 oZ 2929 RANGE GUARD - RG 2.5 GALLON rx--Detectors shall be located over-every piece of equipment. $ ��3 NfW=2 �W Piping Material BLACK SCH 40 Max. Rise 10' MAX. FLOW POINTS = 8 (SUSED) - The=S stem installed as emiinnfacturers specs and the AHJ. p g TOTAL PIPE VOLUME NOT T(YEXCEED 139 CUBIC INCHES y p p ����� n n n -A-The System has been installed-es--per �oQWN Z ��z �QQ RG 2.5 Supply Pipe Size 1 2 Branch Pipe Size 3 8 DROPS 3 8 MAX. PIPE LENGHT 63.4 FTC _- �=w n =- -z The following functions to operafe- upon system discharge: w=� � REW'Z -w' Gas Valve Type: MECH Size 3 4 Manufacturer ASCO - -* - * -R�o� ��Z�o3 �3Nw Supply air damper closes Gas fuel shuts off in kitchen 0 W=.F 0YZ o� Detector Temperature Rating: 360' * Exhaust fan remains on * Electric fuel shut off under hood <oWog ;�F Ow oQ axwz Hood Size: 5-O" Duct Size: 8nx8" RG-2.5 GAL. CYLINDER #60-120002-001 OR MOUNTING BRACKET #9197263 All systems to activate simultaneously in same hazard area. _ s �dsao=a. a ol; * Fire Alarm shall activate. _ CONTROL HEAD - #6120099 - � o EQUIPMENT SURFACE NOZZLE — =x--Manual Pull Station shall bFlocated a minimum of 10 ft. from QTY. TIP#/QTY. LOCATIONS DISCHARGE ADAPTER KIT _ #844908 =hood- &'a maximum of 20 f=from- hood and 4 ft from floor. TYPE AREA HEIGHTS = c , n n n " n n VENT PLUG #9196984 x All fuel sources are GAS unless otherwise noted. ,: I��1 0 0 DUCT 1 8 x8 ADP 1 0"-6" 0"-6" IN OPENING MICROSWITCH KIT SPDT #B120039 °' •py r PLENUM 1 5'-0" ADP 1 0"-6" FROM END OF PLENUM ADP NOZZLE #87-120011-001 __ 4 )�: m 6 BURNER RANGE 1 36"x28" LPR 2 16"-20" CENTER LPR NOZZLE #87-120024-001 CODE REFERENCES: (TYPE 1 GREASE HOOD) o v FLAT GRIDDLE 1 12"x24" ADP 1 13"-48" ON PERIMETER AIM WITHIN 3' CTR. 360' LINK #WK-282664-000 = o v LINK HOUSING #804548 THIS INSTALLATION IS IN CONFORMANCE WITH: r MANUAL RELEASE #B875572 - NFPA 17A - 2017 T - NFPA 10 - 2018 Q a m %" GAS VALVE #13120071 - NYS MECHANICAL CODE 506,507,508 �I - ASTM E2336 - 2016 U = N - THE BUILDING AND FIRE CODES OF NEW YORK STATE - 2020 �' a' o O Z M M A FIRE EXTINGUISHER WITH A MINIMUM RATING L ° M OF CLASS K MUST BE INSTALLED WITHIN THE VICINITY OF THE COOKING AREA. - - a- Component Description tip^'.;• - - A " B TOP OF ' CENTER OF CYLINDER'AI.vE t:::' DISCHARGE PORT 3 -•NOMCINAL CYUNDER DIAMETER Pure 2.1. Dimensions(if Cylinder and Valve Assembly. P/N 13-12XXXX Refer to FVwe 5-26 for Cylinder Valve details. Table 2-1. Cylinder and Valve Assembly Specifications Cylinder and Valve MAx1mu- Dimensions Assembly Part Number Model Flow Number (Old P/N) A B C 60-120001-001 RG-1.25G 4 15-1/4 in. 13-3/4 in'. 8 in. (B120001) (387 mm) (349 mm) (203 MM) 6Q 0 a2-001 �R i 8 21 in. 1"/8 in. 9 in; B120002) (534 mm) (498 mm) (230 60-120003-001 RG-4GS 12 19 in. 17-1/2 in. 12-1/4 (B120003) (483 mm) (444 mm) (311 mxn)' 60-120006-001 RG-4GM 12 24-"in. 23 in. 10 in. m) (2 (B120006) (619 mm) (584 m54 mm) 60-12OW5-001 RG-6G 18 35-1/8 in. 33-3/4 in. 10 in. (B120005) (892 mm) (857 mm) (254 mm) Note: It is permisible to use old and/or new cylinders Included in this manual on a Range Guard system. P/N 60-9127100-000 2-3 April 2009 Component Description 2-1.1.1 CYLINDER BRACKETS A -10 CYLINDER STRAP CYLINDER STRAP .tlBtltlNt06dlttli Fd s nITTittUlftll_ 4 .�. ,. Inv "cSff'43Dii of'-4tiSFt4ii; 46.i` ' i?�Jt11Iif/Iflfititliibu11;8-1I11011f It18;� O O i I B B I� I I 1 O -. —I G-►I FRONT VIEW SIDE VIEW Figure 2-2. Mounting Brackets Table 2-2. Mounting Bracket Dimensions Dimensions Part No. Model A B C 9197430 RG-1.25G 3 in. 9-3/8 in. 1-3/8 in. (76 mm) (238 mm) (35 mm) j 9197263 RGT2T5TG 4-1/2 in. 12 in. 2-1/2 in. (114 mm) (305 mm) (64 mm) 9197414 RG-4GM 4-1/2 in. 20-1/2 in. 2-1/2 in. (114 mm) (521 mm) (64 mm) 9197415 RG-4GS 4-1/2 in. 11-1/2 in. 2 in. (114 mm) (290 mm) (51 mm) Aprll 2009 2.4 P/N 60-91271004000 component Description Table 2-5. Range Guard Nozzles Part Number Flow Number Grooves Nozzle ape (Old Part Number) AUl'Nozzle 87-120011-001 1 (BI2001 1) F Nozzle 87-120012-001 2 2 (BI20012) GRW Nozzle 87-120013-001 1 3 (BI20013) R Nozzle 87-120014-001 1 4 (BI20014) DIM Nozzle 87-120015-001 3 0 (B120015) LPF Nozzle 87-120022-001 2 1 &4 (BI20022) in ftpfflN9zz1-M 87-120024-001 1 Disc&Core (BI20024) Note: It is permissible to use old and/or new nozzles included in this manual in a Range Guard L system. Aprfl 2009 2-8 P/N 60-91271004000 Component Description 2-3.3 Mechanical Gas Valve, P/N B22007X A Mechanical Gas Valve is required on systems used to protect gas-fueled appliance(s). Upon system actuation, the control stem closes, stopping the gas flow to the appliance(s). Note: Only Mechanical Gas Valves that are specifically UL listed and identified by part number in this manual may be used with the Range Guard system. CONTROL STEM INLET OUTLET hr- µ i Figure 2-42. Mechanical Gas Valve. P/N B 12007X Table 2-17. Mechanical Gas Valve Sizes Pipe size Part Number 3J4 (Zr9 mm) B 120071 1 in. (25.4 mm) B120072 1-1/4 in.(32 mm) B120073 1-1/2 in.(38 mm) B120074 2 in.(51 mm) B120075 2-1/2 in.(64 mm) B120076 3 in.(76 mm) B120077 April 2009 2-38 P/N 60-9127100-000 Component Description 2-2 CONTROLS 2.2.1 UNIVERSAL CONTROL HEAD (UCH) Control System, P/N B120099 The UCH Control System, P/N B120099, is used for actuating the Range Guard Cylinder and Valve Assembly. The UCH Control System can be attached to the System Valve Actuator, P/N B120042 for direct cylinder mounting,or to a wall for remote mounting.Knockouts are provided to accommodate either type of mounting. The controller can be operated with: • Automatic mechanical detection (fusible-links and thermo-bulb links), • Automatic electrical operation, and • Remote and local manual operation. f 9-7/16 in. (240 mm) JJ \A � A 3-3/4 in. 8-3/16 in. (95 mm) (208 mm) Figure 2-15. UCH Control System, P/N B120099 P/N 60-9127100-000 2-13 Apri12009 Component Description 2-2.4 Remote Manual Releases 2-2.4.1 REMOTE MANUAL RELEASE, P/N B875572 (UCH ONLY) The Remote Manual Release,shown in Figure 2-35,is provided as a means of manually actuating the system from a remote location. The Remote Manual Release is attached to the UCH Control System with 1/16-inch control cable.To actuate the system at the Remote Manual Release,pull out the safety pin and pull hard on the handle. Each Remote Manual Release is supplied with a separate nameplate. This nameplate must be attached to the mounting surface 1-inch above or below the Remote Manual Release. z (92.2 mm) B x ay 1-1/2 in. /(38 mm) Figure 2-35. Remote Manual Release, P/N B875572 P/N 60-9127100-000 2-31 April 2009 Component Description 2-2.3.2 UNIVERSAL-LINK HOUSING HIT, P/N 120064 The Universal-Link Housing Kit, shown in Figure 2-29, consists of the following. Table 2-12. Universal Link Housing Kit,P/N 120064 item Quantity 11-1/2 in.(292 mm)Detector Housing 1 Crimp Sleeves 2 "S"Hooks 2 The items above are used to attach the Fusible-Link or Thermo-Bulb Links to the 1/16-inch cable leading to the UCH Control System or A+ Control Box.The Universal-Link Housing can be configured as an End-of-Line or In-Line bracket. 1116 in.CABLE TO CONTROL SYSTEM (NOT SUPPLIED) "S"HOOKS CRIMP SLEEVE Zg�mml ~� � THERMO-BULB LINK �'►112l \n , LOCKNUT OR FUSIBLE-LINK J (NOT SUPPLIED) (NOT SUPPLIED) Y THERMO-BULB LINK OR FUSIBLE-LINK (NOT SUPPLIED) CRIMP SLEEVE 112 in.EMT CONNECTOR EXAMPL�OFIN=LINE EXAMPLE OF END-OF-LINE "S"HOOK NOT SUPPLIED) UNIVERSAL-HOUSING KIT UNIVERSAL HOUSING KIT ( Figure 2-29. Example of End-of-line and In-line Universal Link Housing Kit, P/N 120064 P/N 60-9127100-000 2-25 April 2009 Component Description 2-2.3.2 UNIVERSAL-LINK HOUSING KIT,P/N IL20064 The Universal-Link Housing Kit, shown in Figure 2-29,consists of the following: Table 2-12.Universal Link Housing Kit,P/N 120064 item Quantity 11-1/2 in.(292 mm)Detector Housing 1 Crimp Sleeves 2 'S'Hooks 2 The items above are used to attach the Fusible-Link or Thermo-Bulb Links to the 1/16-inch cable leading to the UCH Control System or A+Control Box.The Universal Link Housing can be configured as an End-of-Line or In-Line bracket. 1116 In.CABLE TO CONTROL SYSTEM (NOT SUPPLIED) "S"HOOKS CRIMP SLEEVE 1(2�n.129Zfi�1 �` h. LOCKNUT THERMO-BULB LINK (✓1q _ (NOT SUPPLIED) OR FUSIBLE-UNK (� (NOT SUPPLIED) THERMO-BULB LINK -� OR FUSIBLE-LINK (NOT SUPPLIED) CRIMP SLEEVE 112 in.EMT CONNECTOR EXAMPLE OF IN"LINE EXAMPLE OF END-OF-LINE ��S"HOOK (NOT SUPPLIED) UNIVERSAL HOUSING KIT UNIVERSAL HOUSING KIT Figure 2-29. Example of End-of-line and In.-line Universal Link Housing Kit, P/N 120064 P/N 60-9127100-000 2-25 April2009 Component Description 2-2.1.6 MICROSWITCH KIT, P/N B 120039, B 120039-501 (FOR UCH) The Microswitch Kit is a single pole, double-throw switch(see Figure 2-21 and Table 2-7).Included in the kit is the microswitch,pigtail assembly and four mounting screws(two short and two long). Note: Microswitch Kit P/N B 120039-501 includes pigtail assembly with white stripes. The wire leads are 24-inches (610 mm)in length.Four Microswitch Kits can be mounted in the UCH Control System. There are two mounting locations to accommodate the four Microswitch kits (two stacked at each mounting location), with EMT ports for each mounting location. This allows for the use of two electrical)unction boxes for separation of signal lines and AC lines. These are used when it is necessary to open or close electrical circuits.The following are examples, but not limited to: • Electric appliance shutdown • Make up air shutdown • Electric gas valve shutdown • Shuntbreaker/relay Note: Not for alarm initiation. Electrical appliances usually have a higher amp rating than the switches.In this case,such appliances shall not be wired directly to the microswitch.A magnetic contactor or relay must be used. To wire the microswitch for UCH, refer to Figure 4-30. ELECTRICAL CONNECTOR - 'd MICROSWITCH Figure 2-21. Microswitch Kit,P/N B 120039 Table 2-7. Microswitch Electrical Ratings 125/250 Vac 20.5 Amps 250 Vac 1-1/2 HP 125 Vac 1/2 HP April 2009 2-18 P/N 60-9 1 27 100-000 Component Description 2-2.3.7 CORNER PULLEY.P/N VITK4 648-9W The Corner Pulley is used to change the direction of the control cable runs. The cable's protective conduit(1/2-inch EMT)is attached to the Comer Pulleys with the coupling nuts provided.The Corner Pulley is equipped with a ball-bearing pulley for minimum resistance to the cable travel. 3 in. (76.2 mm) 3 in. (76.2 mm) �a Figure 2-33. Corner Pulley.P/N WK 844648-900 P/N 60-9127100-000 2-29 Apri12009 System Design 3-6 VENTILATION 3-6.1 Plenums Table 3-29. Plenum Protection Items Parameters ADP Nozzle No Filter 1 10 ft.x 4 ft. (3 m x 1.2 m)Max. 1 -located at one end of the plenum "V"Fitter 10 ft.x 4 ft.(3 m x 1.2 m) 1 -located at one end of the plenum A 20 ft x 4 ft. (6 m x 1.2 m) 2-located at end of plenum pointing inwards "lpg eO M ter, 10 ft.x 4 ft.(3 m x 1.2 m) 1 -located at one end of the plenum 20 ft.x 4 ft.(6 m x 1.2 m) 2-located at end of plenum pointing inwards 1 when no filters are present,the nozzle protecting the plenum is used to discharge the wet chemical on the under- side of the hood.In this case,the hood may not exceed a length of 10 ft(3 m)or a width of 4 ft.(1.2 m). Plenums larger than 10 ft. (3.0 m)x 4 ft. (1.2 m)may be protected by adding additional ADP nozzles for each additional 10 ft. (3.0 m)of plenum length and each additional 4ft. (1.2 m)of plenum width. Nozzles may be installed pointing in the same direction, and/or at the ends of the plenum pointing toward each other(see Figure 3-28).Each nozzle will provide coverage for a maximum of 10 ft. (3 m) of plenum length and 4 ft. 11.2 m)of plenum width. ADP nozzles must be centrally located in the plenum with their discharge directed along the length of the plenum and located in relation to the filters as shown in Figure 3-28.Refer to Figure 3-28 for filter height. P/N 60-9127100-000 3-33 April 2009 System Design 3-6.1.1 DUCTS The ADP nozzle, P/N 87-120011-001, is used for protection of the exhaust ductwork. The duct cross section can be any shape, not including obstructions (i.e., round, square, or rectangular)and the duct itself can be of unlimited length. In accordance with NFPA 96, the exhaust fan should be left running at the time of system discharge.This will help to remove smoke and other airborne materials and gases from the hazard area in the event of a fire. Check with the Authority Having Jurisdiction for local requirements. A damper, if present, should be left open at system discharge. However,if the damper is closed,the system designer must insure that additional nozzles are required. 3-6.1.1.1 Protection of Ducts O to 50 inches in Perimeter One ADP nozzle, P/N 87-120011-001, is required for protection of a duct with a perimeter up to 50- inches(refer to Figure 3-29). Length of duct is unlimited. The nozzle is located at the geometric center of the cross-sectional area that it is protecting, and is located in the duct within six inches of the entrance. Note: All Range Guard systems are listed by UL and ULC for use with the exhaust fan either on or off when the system is discharged. DUCT HOOD DUCT PERIMETER UP TO AND INCLUDING 50 in.(1270 mm) 11.78 in.(300 mm) 15.91 in. MAX.DIAGONAL (404 mm) 4 MAX. `!--..Bn in. " 11.78 in.(300 mm) 12.5 'f MAX.DIAGONAL (318 I 1 A MAX.X. _ SQUARE DUCT RECTANGULAR DUCT 2"A"+2"8"=65 in.(1651 mm) ROUND DUCT (L OF VERTICAL DUCT ' ADP NOZZLE VERTiCAUHORIZONTAL DUCT AIM POINT 0-6in.(0.152mm) f ADP NOZZLE j 4. OF HORIZONTAL DUCT DUCT ENTRANCE 2 to 4 in.(51 to 102 mm) NOZZLE TIP to DUCT HIP Figure 3-29. Duct Protection Using Singe ADP Nozzle,P/N 87-120011-001 P/N 60-9127100-000 3-35 April 2009 '3�r System Design .5i 3-4.12 Four Burner Ranges (LPR), P/N B120024 The low proximity range top coverage provides protection for a range top that has a back shelf or a:wyv, .1C broiler integral to the regular range. Y'= Table 3-16. LPR Nozzle Coverage,Area—Four Burner Range Items Parameters vA. MaximmHazard Area 24 in.x 24 in. (610 mm x 610 mm) Midpoint of hazard area No ,„ Nozzle Location—Dimension A in Figure 3-13 Refer to'Fable 3-17 ; Table 3-17.LPR Nozzle Parameters Burner Spacing Centerline to Centerline Nozzle Height (Dimension A) (Dimension B in Figure 3-13) (centrally over the range and under shelf broiler) Note: Shape of burner not important. s y. 14 in. (356 mm) 16 in.(406 mm)Min. €.: '20 in.(508 mm)Mays- Between 12 in.and 14 in.(305 mm and 432 mm) 16 in(406 mm)Min. .: s 17 in(432 mm)Max. (4; 13. [1�3et�wee�nilOn. and 12 in. (254 mm and 305 mm) 16 in.(406 mm) .s ,6 i fit 1 Vri• ft. DIMENSION"A" 1 '•k;" (NOZZLE HEIGHT AN LPR NOZZLE MAY BE LOCATED OVER THE CENTER t TOP OFBURNERS TO 1 OF THE HAZARD AREA.SEE t� 1 TABLE FOR NOZZLE HEIGHTS. -, 14<. 1 a t. AM POINT.MIDPOINT OF �k � HAZARD AREA f .k{ _1 24 Im(610 mm) DWENStw a" :,;$' ; {; q f ti\ 5 . 1)j "G E DIMENSIONS" .•, HAZARD AREA 1NIDTH tirf �i,X Figure 3-13. LPR Nozzle Coverage for a 4-Burner Range (LPR) P/N 60-9127100 0 .,, System Design 3-4.20 Griddle—Flat Cooking Surface (With or without Raised Ribs) Table 3-26.ADP Nozzle Coverage Area Items Parameters Maximum Hazard Area 30 in.x 42 in. (762 mm x 1067 mm) Nozzle Aim At a point 3 in.(76 mm)from the midpoint of hazard area Nozzle Location—any point on the perimeter of 13 in. (330 mm)Min. appliance 48 in. (1219 mm)Max. Note:Positioning the nozzle directly over the appliance is not permitted. ♦ 48 in. (1219 nun) MAX. 1 30 In. (762 MM) 13 In. MAX. MIN. TOP OF APPLIANCE AIM POINT.3 in.(76 nun)RADIUS FROM 42 In. THE MIDPOINT OF HAZARD AREA (1067 mm) MAX. Figure 3-22. Griddle-Flat Cooking Surface P/N 60-9127100-000 3-27 April 2009