Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
51384-Z
of SOUIyo(o Town of Southold * * P.O. Box 1179 ,oA 53095 Main Rd �rCOUNTI-,¢'1 Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47111 Date: 06/03/2026 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 200 Green Hill Ln Greenvort, NY 11944 Sec/Block/Lot: 33.-3-13 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 09/30/2024 Pursuant to which Building Permit No. 51384 and dated: 11/15/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof mounted solar to existing single family dwelling as applied for. The certificate is issued to: Nicholas Sourbis , Karen Lucia Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51384 1/28/2025 PLUMBERS CERTIFICATION: )1;0h uth WSignat *of Sao. TOWN OF SOUTHOLD BUILDING DEPARTMENT G ' TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51384 Date: 11/15/2024 Permission is hereby granted to: Nicholas Sourbis 200 Green Hill Ln Greenport, NY 11944 To: Install roof mount solar to existing single family dwelling as applied for. Disconnects must be located on the exterior, labeled,and readily accessible. Premises Located at: 200 Green Hill Ln, Greenport, NY 11944 SCTM#33.-3-13 Pursuant to application dated 09/30/2024 and approved by the Building Inspector. To expire on 11/15/2026. Contractors: Required Inspections: Fees: CO-RESIDENTIAL $100.00 ELECTRIC -Residential $125.00 SOLAR PANELS $100.00 Total $325.00 Building Inspector pE SO!/r�ol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 11971-0959 �p • �o Jamesh southoldtownny.gov Owl BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Nicholas Sourbis Address: 200 GreenIA1 1I Lane city:Greenport st: New York zip: 11944 Building Permit* 51384 section: 33 Block: 3 Lot: 13 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Element Energy LLC. Electrician: Jamie Minnick License No: 52689-ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Surrey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Sump Pump Other Equipment: 5.76kw roof mounted system with 18 panels[JKM425N-54HL4-b] 18 micro inverters [Enphase IQ8MC-72-M-US] 1 Combiner panel Notes: SOLAR ENERGY PV SYSTEM Inspector Signature: IX04 Yq4& Date: January 28, 2025 200 greenway lane -- OE SOUlyO '/3 0 / ti �o # # TOWN .OF. SOUTHOLD f3UILDING DEPT. courm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND. . [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE_& CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [K] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Sbla� N�lj v DATE g INSPECTOR f I�j' ` ho��,oF souryOlo TOWN OF SOUTHOLD BUILDING- DEPT. 'c ou �0 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] NSULATION/CAULKING [ ] FRAMING/STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [. ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION. [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) j ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 1 A�� DATE �'ab'�a -INSPECTOR Page 1 of 1 Southold town , Current 1/5/2025 t�l..r mews des De����s-nent Engineering Blowing Subject: Structural Observation Report Job: Sourbis, Nicholas - 200 Green Hill Lane Project Address: 200 Green Hill Lane, Greenport, NY, 11944 Attn.: To Town of Southold I have reviewed the solar energy system installation in the subject topic on 05/15/2025. The units have been installed on in accordance with the manufacturer's installation instructions and the construction drawings approved by the Building Department, Town of Huntington, New York. The solar panel installation is in compliance with the requirements of the 2020 Residential Code of New York State, SEI/ASCE 7-16, and current industry standards and practices and based on documentation and data supplied by Element Energy at the time of this report. To the best of my belief and knowledge, the work in this document is accurate, conforms to the governing codes and standards applicable at the time of submission and conforms with reasonable standards of practice with the view to the safeguarding of life, health, property, and public welfare. This letter does not waive the installer of any responsibility for improper installation. If you have any further questions on the above, please do not hesitate to reach out. 6 NEw yO Current Renewables Engineering Inc. *� ��PSH Zq y��t Professional Engineer oe info@currentrenewableseng.com �? 101084 Exp.01/31/2028 Signed on:1/5/2025 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com FIELD INSPECTION REPORT I DATE COMMENTS f_� b V_ FOUNDATION (1ST) -- - --- �� -------------------------------------- � C FOUNDATION (2ND) z 0 O H ROUGH FRAMING& ,� r PLUMBING � W 1 INSULATION PER N.Y. - STATE ENERGY CODE FINAL ADDITIONAL COMMENTS o 3- - a S ►moo s-{- ce r4- ►-f- -I O ,\a-C z a-ac� — o Nand � o o z E~ H d b o SVF>ot r�4 + TOWN OF SOUTH OLD —BUILDING DEPARTMENT ofi Town Hall Annex 54375 Main road P. ®. Box 1179 Southold, NY 1 1 97 1-0959 j y • o� ;> Telephone (611) 765-1802 Fax (631) 765-9502 https:,`.,wwtiv.southoldtownny.Uov i Date Received APPLICATION FOR BUILDING PERMIT Tr . , For Office Use Only PERMIT NO. Building Inspector:I R�> SEP 2 7 2024 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Building©efyartrnent � Owner's Authorization form(page 2)shall be completed. � Town e;aou:Ji+�Jd ! ate®ate: OWNER(S)OF PROPERTY: � i Name: /v/)t n h D J qs & vr&s SCTM# 1000- 3 ,0 U -b 3'00 -v 1 ,000 Project Address: / I 02 0� C'r�en t�1 ll � �rte� d,'t dl R �iC Phone#: G 3 I- 9 8 - -7 0 Lt I Email: ��I/ 1�- Mailing Address: I CONTACT PERSON- Name: LD r-lr`A-i of Mailing Address: '7 4. o S vu.d a� Belt---�'�► I 7 Phone#: (D �-7 0 q l Email: P-e rr ►+5 aS ysyam, i j DESIGN PROFESSIONAL INFORMATION, Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Mailing Address: a� V® �. r/tn�I� ,���� ��✓�n q� Phone#: v 159 ,') D Lh Email: � ��s co.,,s cS com DESCRIPTION OF PROPOSED':CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: Cher l>nS+a-d BSc, 4L,- P y 5y 5-1-e kn $_ 02 4. 1 7 `Z Will the lot be re-graded? ❑YesXNo Will excess fill be removed from premises? OYes"131610 I I i l I 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or us istrict in which premises is situated: Are there any covens_nt�,and restrictions with respect to this property? E]YeknNo IF YES, PROVIDE A COPY. eck Box After Reading: the ownei/contractor/design professional is responsible for drainage and storm water issues as provided by Chapter 236 of the Town Code..APPUtATIOMIS"HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of-the Town of Southold;Suffolk,County,New York and other applicable Laws,Ordinances.or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted name):Lorraine Lorraine ®iPenta pp B Y(print ) ®Authorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Lorraine ®iPenta being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this n aday of Nota Public PROPERTY OWNER AUTHORIZATION. LOUTS J ROMEO (Where the applicant is not the owner) Notary Public,State of New York No.01 R06314813 Qualified in Suffolk County 1^ Commission Expires November 1.7,20�b I, V ),ch- 0 14s So&cr b)3 residing at 9oL9 C)rk-c 1 f>? ,j tir> do hereby authorize 1 L,P471.Qi Oyu-f?fU L�-C to apply I on my behalf to the Town of So thold B�ding Department for approval as described herein. Owner's Signature Date ZX N,'�C l V� LOUIS J ROMEO o I�� �© ,As— V ` S Notary Public,State of New York Print Owner's Name No.01 R06314813Qualified in Suffolk County Commission Expires November 17,.20 Z-6 2 �o�guff0�,�`o BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD y x Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 �'y& �0�� Telephone (631) 765-1802 - FAX (631) 765-9502 l ' iameshO-southoldtownny.4ov—seand(cr_southoldtownny q ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 7� Company Name: EI�irr� i - <L, �• ��, Electrician's Name: License No.:5,2 g cl-t-(15 Elec. email: Pe-rM C e,a,5 Elec. Phone No: g 5 t_7-7ct-`?c)c'13 Z request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: Al ! ` Cho 1 as Address: a00 ( rccn w Lka I G� NV d et L1 Cross Street: Phone No.: Le 3 L - 7 ? 0(-'1CV1t Bldg. S �� email: P*srano$s G e.Qs s,C if) Tax Map District: 1000 Section: d Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Circle All That Apply: Square Footage: Is job ready for inspection?: ❑ YES U NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals n 1 2 D H Frame D Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION a S PROVED AS NOTED OCCUPANCY OR APPROVED s/3� E IS UNLAWFUL DATE a •P•� USE FMQS3dEav BY: WITHOUT CERTIFICATE NOTIFY BUILDING DEPARTMENT AT 631-765-180 AMT0 PM FOR THE OF OCCUPANCY 8 FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION ALL CODES OF 4. FINAL-CONSTRUCTION MUST COMPLY WITH TOWN GppES BE COMPLETE FOR C.O. Np CpN�IT' OF ALL CONSTRUCTION SHALL MEET THE NEW Y lRn D ATE& REQUIREMENTS OF THE CODES OF NEW AS FEQ m YORK STATE. NOT RESPONSIBLE FOR �OWNPNING9OAS0 DESIGN OR CONSTRUCTON ERRORS o S0VoID� n � SCND RETAIN STORM WATER RUNOFF PURSUANT TO CODETE OF THE TOW Page 1 of 2 , Current 09/26/2024 a l e s R n �n� Element Energy LLC -- Engineering 7470 Sound Avenue, Mattituck, NY, 11952 Subject: Structural Certification for Installation of Residential Solar Job: Sourbis, Nicholas - 200 Green Hill Lane Project Address: 200 Green Hill Lane, Greenport, NY, 11944 Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of Element Energy LLC. After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout. Please see full Structural Calculations report for details regarding calculations performed and limits of scope of work and liability. The design criteria and structural adequacy are summarized below: Design Criteria Code: 2020 NYSBC, IBC 2018, ASCE 7-16 Risk Category: II Ult Wind Speed: 128.0 mph Ground Snow: 25.0 psf Min Snow Roof: N/A ap:09/30/2025 ,,&OF NEW j, A. 1qa0 Current Renewables Engineering Inc. Professional Engineer F info@currentrenewableseng.com �► 2J'�OA 106793 F NP Signed on:09/26/2024 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com Page 2 of 2 Summaries: Check 1: Shingle roofing supported by 2x10 Rafter @ 16 in. OC spacing. The roof is sloped at approximately 27 degrees and has a max beam span of 17.0 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.coM ROOF MOUNT SOLAR PERMIT PACKAGE OF NEwY NICHOLAS SOURBIS - *�.1\1 I A. lgar o��* 7.650 KW DC GRID TIED PHOTOVOLTAIC SYSTEMtil y z 200 GREEN HILL LN, GREENPORT, NY 11944 sFo 106793 p'�OFESSION�� Exp:9/30/2025 STAMPED 09/26/2024 AERIAL VIEW VICINITY VIEW CODE INFORMATION GENERAL NOTES THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW.REPRODUCTION IN -- -�--- - ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC PRIOR WRITTEN APPROVAL FROM CURRENT t_ 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY RENEWABLES ENGINEERING INC. POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: SOLAR PHOTOVOLTAIC INSTALLATION 2020 BUILDING CODE OF NEW YORK STATE 2. THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES 2020 RESIDENTIAL CODE OF NEW YORK STATE 3. PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED Current 4. ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE 2020 EXISTING BUILDING CODE OF NEW YORK STATE UNDERSIGNED• � ReI1e W c�bleS 2020 FIRE CODE OF NEW YORK STATE 5. ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703,UL1741 AND Engineering 2020 PLUMBING CODE OF NEW YORK STATE UL1703 2020 MECHANICAL CODE OF NEW YORK STATE 6. ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT % %' j • CURRENT RENEWABLES ENGINEERING INC. 4;. N 2017 NEW YORK STATE ELECTRICAL CODE SUCH AS GEO CEL 2300 CLEAR SEALANT 3600 Lime street,6ldg 2 Riverside,CA 92501 Email:Prajects@creng.solar t 7. THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL wecsHe:-cmng.co JURISDICTION AND THE UTILITY IS OBTAINED PHONE:(951)-215-6354 8. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, CONTRACTOR INFO a AHJ: TOWN OF SOUTHOLD MECHANICAL,OR BUILDING ROOF VENTS" f 9. IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE,IT c_. IS THE NECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE LEGEND 10. EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE UTILITY METER PM PRODUCTION METER MANUFACTURER'S INSTALLATION INSTRUCTIONS" CZSYS� 11. A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH OSHA I msP MAIN SERVICE PANEL wV INVERTER REGULATIONS ELEMENT ENERGY LLC. H 12. MAX HEIGHT OF MODULES OFF OF ROOF FACE:<6"' 7470 SOUND AVENUE,MATTITUCK, BUILDING INFORMATION COMBINER sue SUB PANEL 13. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O17 NYSEC. NEW YORK,11952 7993 14. -PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PH: 779 services@e2rys.co.tom 2 STORY HOUSE SINGLE FAMILY RESIDENCE 11 MODULE LP BACKUP LOAD PANEL GROUNDED IN THE INVERTER,AND SYSTEM COMPLIES WITH 690.35." Licence-ELECTRICIAN) 15. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. (MASTER -HI-67461 Licence-HI-67461 U ROOF OBSTRUCTIONS I(� IQ CONTROLLER 2 16. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. (SUFFOLK HOME IMPROVEMENTI CONSTRUCTION TYPE:V-B OCCUPANCY: R3/U 36"ACCESS PATHWAYS 17. ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED,LABELED,AND INSTALLED PER ATr BATTERY THE NYSEC,THE INSTALLATION STANDARDS/MANUFACTURER'S RECOMMENDATIONS NICHOLAS SOURBIS 18"ACCESS PATHWAYS AND IF REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. APN : 1000033000300010000 18. CONDUITS EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/8" 200 GREEN HILL LN, QH Q.HOME HUB ABOVE ROOF SURFACE. SHEET INDEX ROOF ACCESS POINT GREENPORT, NY 11944 19. IN EXPOSED LOCATIONS,WIRING AND CABLING SHALL BE IN CONDUIT OR CABLE SHALL MAIN BREAKER AC ESS DISCONNECT BE RATED FOR EXPOSURE;TYPE NM CABLE ALLOWED IN PROTECTED LOCATIONS. AHJ TOWN OFSOUTHOLD PV-1.0 COVER PAGE MBE ENCLOSURE WITHIN ATTIC SPACES,ALLOWED TO RUN TYPE NM(ROMEX)10/3 OR 12/3 CONDUCTORS 1 C LOAD CENTER THROUGH OPEN SPACE OR TYPE THHN IN MINIMUM 3/4"ALUMINUM CONDUIT LONG ISLAND POWER AUTHORITY AUTOMATIC TRANSFER 20. MATERIALS,EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS, UTILITY (UPA) PV-2.0 SITE PLAN TS SWITCH STANDARDS,RULES AND REGULATIONS OF THE FOLLOWING AND BE MOST SUITABLE PV SUMMARY SEPTIC TANK PV-2.1 ROOF PLAN TO THE PURPOSE INTENDED: SYSTEM SIZE OP PERMANENT ANCHOR (KWDC) STC 425 X 16 = .650 PV-3.0 STRUCTURAL SSS LEACH LINES TT c 398., x ,B = .,ss SYSTEM SIZE PV-4.0 ELECTRICAL 3LD TO TEMPORARY ANCHOR PROPANE TANK WIND SPEED 128 (KWAC) 5.76 @24D INKO SOLAR PV-4.1 ELECTRICAL SLD IL O JKM425N_54 WELL SNOW LOAD 25 MODULES � ,S JKM425N-54HL4-B INSTALLER LADDER MICROINVERTER ,8 QgMHASE M-US PV-4.2 ELECTRICAL PHOTOS 0POWER LINES EXPOSURE CATEGORY B PV-5.0 BOM STUB-OUT NO LADDER ACCESS 0 (STEEP GRADE STRUCTURAL NOTES : PV-6.0 SIGNAGE &PLACARD ® SKYLIGHT 1. THESE PLANS ARE STAMPED FOR STRUCTURAL CODE OR GROUND LEVEL COMPLIANCE OF THE ROOF FRAMING SUPPORTING THE PROPOSED PV-7.0 SPECS+ RESTRICTED ACCESS OBSTRUCTIONS) PV INSTALLATION ONLY. GAS GAS SHUT OFF Rev Description Date 2. THESE PLANS ARE NOT STAMPED FOR WATER LEAKAGE. 0 INITIAL DESIGN 9/26/2024 CONDUIT H2o WATER SHUT OFF 3. PV MODULES, RACKING,AND ATTACHMENT COMPONENTS MUST A FOLLOW MANUFACTURER GUIDELINES AND REQUIREMENTS. B O7 SERVICE DROP 4. PLEASE SEE THE ACCOMPANYING STRUCTURAL.CALCULATIONS PROJECT# NA REPORT FOR ADDITIONAL INFORMATION. DATE DRAWN 9/26/2024 RAIL 5. PRIOR TO COMMENCEMENT OF WORK, THE SOLAR INSTALLER DRAWN BY E.R RAFTER SHALL VERIFY THE ROOF FRAMING INFO BEFORE INSTALLATION AND SHEET# PV-1.0 ATTACHMENT NOTIFY THE E.O.R. IF THERE IS ANY INCONSISTENCY BETWEEN SITE TITLE VERIFICATION AND FOLLOWING: 2x10 RAFTERS @ 16"OC SPACING COVER PAGE WITH MAX UNSUPPORTED SPAN EQUAL OR LESS THAN 17 FT. R324.6.1 PATHWAYS: NOT LESS THAN TWO MIOMUM 36-INCH WIDE PATHWAYS ON LEGEND SEPARATE ROOF PLANES, LOT NO : 0.51 Acres OF NE FROM LOWEST ROOF EDGE TO RIDGE,SHALL BE PROVIDED ON ALL BUILDINGS. 0�R1 A. (,4���,� AT LEAST ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR UM UTILITY METER DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY,A MINIMUM SP MAIN SERVICE PANEL 36 INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO RIDGE r SHALL BE PROVIDED ON THE SAME ROOF PLANE OR STRADDLING THE SAME AND ADJACENT ROOF PLANES.PATHWAYS SHALL BE C❑ COMBINER OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS MODULE CFO 106793 ACCESSING THE ROOF.PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES,CONDUIT,OR ENLARGED VIEW J ROOF OBSTRUCTIONS SSIONP� MECHANICAL EQUIPMENT. 36"ACCESS PATHWAYS ExP:9/30/2025 FORP.2SETBACAIC RIDGE: STAMPED 09/26/2024 FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 I ' PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN U M ® 18"ACCESS PATHWAYS THESE DRAWINGS ARE SUBJECTTO COPYRIGHT AN 18 INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A PROTECTION BY US LAW.REPRODUCTION IN HORIZONTAL RIDGE. ANY FORM IS EXPRESSLY FORBIDDEN WTHOUT FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 ROOF ACCESS POINT PRIOR WRITTEN APPROVAL FROM CURRENT PERCENT OF THE PLAN VIEW TOTAL ROOF AREA,NOT LESS THAN A MS P RENEWABLES ENGINEERING INC. 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. Current R324.6.4 EMERGENCY ESCAPE AND RESCUE OPENING:PANELSeyla{rr� r AND MODULES INSTALLED ON DWELLINGS SHALL NOT BE PLACED THE PORTION OFA ROOF THAT IS BELOW AN EMERGENCY ESCAPE t Engineering AND RESCUE OPENING.A 36-INCH-WIDE PATHWAY SHALL BE PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. CURRENT RENEWABLES ENGINEERING INC. 3800 Lime Slmel,Bldg 2 Riverside,CA 92501 NOTES: Email:Projects@creng.solar 1. MINOR FIELD ADJUSTMENTS ALLOWED BASED ON ACTUAL FENCE/GATE W PHONE: (951Y 15-6354 PHONE: 951 215-6354 SITE CONDITION AND MEASUREMENTS. PROPERTY LINE 2. THE 30 SECOND SHUTDOWN REQUIREMENT IS INCORPORATED CONTRACTOR INFO INTO THE 2017 NYSEC AND UL STANDARD 1741. I ROOF OBSTRUCTION 231'-3" 3. EXISTING ROOF VENT SHOULD NOT BE COVERED. don 22'-10' a EZSYStt z ' SHED Sr ELEMENT ENERGY LUC. �•.�.' ' . 7470 SOUND AVENUE,MATriTUCK, J ''` .�DRIVEWAY ° 7I NEW YORK,11952 J PH.(631)779 7993 services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 Z I (SUFFOLK HOME IMPROVEMENT) 1 W I ;J N NICHOLAS SOURBIS o' 130 5 0 -46, ° I 200 GREEN HILL LN, GREENPORT, NY 11944 I AHJ TOWN OF SOUTHOLD a I UTILITY ( AOPNGISLANDPOWERAUTHORITY ) J P ROOF ACCESS POINT 18' SYSTEM SIZE-11" I STCMM 425 X 18 = .650 (KWOC) —L.----------- ------`— - --- --------��—..----�----��--�-----�—�- --�--�� PTC 398.1 X 16 = .166 FENCE 2201-211 I SYSTEM SIZE(KWAC) 5.76 @240 ROOF LINE PATIO PROPERTY LINE MODULES : 18 JKM4SN-54 JINKO SOLAR MICROINVERTER 18 ENPHASE IQSMC-72-M-US Rev Description Date 0 INITIAL DESIGN 9/26/2024 A B PROJECT# NA DATE DRAWN 9/2612024 DRAWN BY E.R SIT E PLAN SHEET# PV-2.0 &� CALE- TITLE S 1/32" = 1'-0" SITE PLAN ARRAY AREA LEGEND + ARRAY ROOF ROOF TOTAL �EOF NE{v y ROOF ROOF PZIMUTH TILT MODULES, AREA AREA AREA AREACOVERED BY COVERED BY uM UTILITY METER c��oO�RI A. �9 D,p� — (Sq.Ft.) (Sq.Ft.) ARRAY(%) ARRAY(%) SP MAIN SERVICE PANEL #1 27° 162° f1/ 378.36 2446 15.47 15.47 - fi C❑ COMBINER Iz V W ❑ F` 9 MODULE �J'FO 106793 uM c O ROOF OBSTRUCTIONS p��FESSI NP� MSP - 36"ACCESS PATHWAYS Exp:9/30/2025 18"ACCESS PATHWAYS STAMPED 09/26/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT RAIL PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT _ RAFTER PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. ATTACHMENT Current ene,=Lies Engineering OCURRENT RENEWABLES ENGINEERING INC. 3600 Lime Street,Bldg 2 Riverside,CA 92501 Email:Pmjects@mng.solar Website:—.creng.co i PHONE:(951)-215-6354 CONTRACTOR INFO I El z EZSYSP ELEMENT ENERGY LLC. J 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 2 PH:(631)779 7993 seices@e2sys.com Licence-ME-52689 7 1 ol (MASTER ELECTRICIAN) Licence-HI-67461 w (SUFFOLK HOME IMPROVEMENn W NICHOLAS SOURBIS Q9 200 GREEN HILL LN, O GREENPORT,NY 11944 1 1-6" AHJ TOWN OF SOUTHOLD UTILITY LONG ISLAND POWER AUTHORITY (LIPA) PV SUMMARY SYSTEM SIZE _ STC 425 X 18 = .650 I I I I I I I (��) PTC 396.1 X 18 = .166 SYSTEM SIZE i 5.76 @240 I cKwnc, I I I I ! I MODULES 18 11NKO SOLAR 1KM425N-54HL4-B I I I I I I I I I I MICROINVERTER 18 ENPH:-7 IOSMC-72-M-US I I I I I I I I I I (N)18 JINKO SOLAR JKM425N-54HL4-B I I Rev Description Date I I I I I I I ROOF#1 0 INITIAL DESIGN 9/2 612 0 2 4 A B PROJECT# NA DATE DRAWN 9/26/2024 DRAWN BY E.R ROOF PLAN SHEET PV-2.1 2 TITLE SCALE: 1/8" = 1 I-OII ROOF PLAN TABLE 1 TABLE 2 _ s, FRAMING TYPE RAFTER ROOF ROOF ROOFING FRAMING FRAMING OC MAX PENETRATION MAX �_OF ANEWy� NO. TILT TYPE TYPE SIZE SPACING SPACING OVERHANG - q O� sz ATTACHMENT IRONRIDGE QUICKMOUNT HALO ULTRA o „ „ " " " F GRIP WITH XR ROOF 1 27 COMP SHINGLE RAFTER 2 X10 16 64 24 r cle, s3 RAIL IRONRIDGE XR-100 RAIL 2 '�ROFESSIONP� Exp:9/30/2025 STAMPED 09/26/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current eeWe Engineering CURRENT RENEWABLES ENGINEERING INC. 3600 Lime StreeLBldg 2 Riverside,CA 92501 Email:Pmjects@cmng.solar Website:—cmng.co PHONE: 951-215-6354 MODULE CONTRACTOR INFO S3 a®� TABLE : PENETRATION CZSYS° s2 GUIDE FOR INSTALL ELEMENT ENERGY LLC. ROOF TWO OR MORE ROWS OF PANELS 747050UND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 services@e2sys.com - Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) 2.5"MIN.EMBED. I I I I I I I I I I I I I I I I I I I I ( I I I I I I I I I I I I I I I I I I I NICHOLAS SOURBIS 17. 200 GREEN HILL LN, GREENPORT,NY 11944 (2)-#14 X 3" SELF DRILLING I I I I I I I I I I I I I I I I I I I I STRUCTURAL SCREWS TO lAHJ TOWN OFSOUTHOLD S1 EXISTING STRUCTURE I I I I I I I I I I I I I I I I I I I I LONG ISLAND POWER AUTHORITY UTILITY (LIPA) PV SUMMARY ENLARGED VIEW STACKED STAGGERED FULLY STAGGERED SYSTEM SIZE (KWDC) STC 425 X 18 = .650 PTC 398.1 X 18 = .166 SYSTEM SIZE 6 76 @240 ONE ROW OF PANELS (KWAC) 3„�, JINKO SOLAR 61I M N MODULES 18 1KM425N-54HL4-B ENPHASMICROINVERTER 18= IOSMC-E IQSMC-72-M-US MODULE I I I I I I I I I I I I I I I I I I I I I I I I I SEE ENLARGED VIEW FULLY STAGGERED STACKED/STAGGERED Rev Description Date —� 0 INITIAL DESIGN 9/26/2024 A B PROJECT# NA DATE DRAWN 9/26/2024 �— ROOF DRAWN BY E.R SHEET# PV-3.0 TITLE ATTACHMENT DETAILS STRUCTURAL BACKFEED BREAKER SIZING METER NO. 98385525 ��OF NEW MAX. CONTINUOUS OUTPUT 1.33A @ 240V ELECTRICAL EQUIPMENT LIST 23.94 X 1.25 = 29.93AMPS 30A BREAKER-OK S.NO. ITEMS DESCRIPTION QTY. ACCOUNT NO.# 9676059104 MA/yj� O'p� SEE 705.12 OF 2017 NYSEC JINKO SOLAR 1 PV MODULE 18 r it 200 X 1.20 = 240 JKM425N-54HL4-B m UJI 240 - 200 = 40AALLOWABLE BACKFEED 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 18 099128 2 ENPHASE IQ COMBINER Z��4 4 CTRIO 3 COMBINER 5/5C 1 ARp SS% (E) UTILITY METER TO UTILITY GRID STAMPED 09/26/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT 3 (N) ENPHASE (E)200A RATED PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT COMBINER BOX MAIN SERVICE PANEL PRIOR WRITTEN APPROVAL FROM CURRENT 1 PH, 120/240V 60HZ U RENEWABLES ENGINEERING INC. (E)200A/2P MAIN Current CELL WIRE LESS BREAKER MODEM COMMS (TOP FED) ene ies Engineering IQ GATEWAY CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Stmet,Bldg 2 Riverside,CA 92501 Emil:Pmjects@cmng.solar 1 A Website:vnvw.aeng.C' 2 PHONE:951)-215-6354 (N)15A� CONTRACTOR INFO r— T I I TO OTHER— 1 BRANCH OF 9 N LOAD �._ PV MODULE I I CZS`/S� (N)20A� I I ' T I ELEMENT ENERGY LLC. L—————— ————————— 7470 SOUND AVENUE,MATTITUCK, (N)20A I I NEW YORK,11952 PH:(631)779 7993 - sLi e'nm-ME-52689 I (MASTER ELECTRICIAN) r--------------- —, r®,�I I Licence-HI-67461 2 BRANCH OF 9 <NV L----------� L----- --------------- (SUFFOLK HOME IMPROVEMENT) PV MODULE i---- -------- I NICHOLAS SOURBIS I 200 GREEN HILL LN, GREENPORT,NY 11944 B AHJ TOWN OF SOUTHOLD MODULE JINKO SOLAR (N)30A/2P PV MANUFACTURER BREAKER UTILITY LONG ISLAND POWER AUTHORITY (E)GROUNDING ELECTRODE — (LIPA) MODULE MODEL JKM425N-54HL4-B PV SUMMARY CONDUCTOR #6 BARE COPPER SYSTEM SIZE STC 425 X 16 = .650 MODULE(W) 425 (moo) PTC 398.1 X 18 = .166 MODULE PTC(W) 398.1 SYSTEM SIZE (KWAC) : 5.76 @240 INKOSOLAR MODULE Isc(A) 13.58 IIKM4 5N_54 NOTE: MODULES : 18 JKM425N-54HL4-B MODULE Voc(V) 38.95 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS MICROINVERTER 18 ENPHASE MODULE Imp(A) 13.13 AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. osnac-72-M-US 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH MODULE Vmp(V) 32.37 PROPER JUNCTION BOX AT EACH END PER 690.31A WIRE CALCULATION STARTING STARTING TEMPERATURE ADJUSTMENT MAXIMUM Rev Description Date CONDUCTOR CONDUCTOR CONDUIT CURRENT FACTOR FOR ADJUSTED CURRENT 0 INITIAL DESIGN 9/26/2024 TAG DESCRIPTION ALLOWABLE TEMPERATURE CORRECTION QTY. SIZE(AWG) SIZE&TYPE AMPACITY RATING (°C) APPLIED TO FACTOR MORE THAN 3 CONDUCTOR APPLIED TO A 310.15(B)(16) CONDUCTORS 310.15(B)(2)(a) CONDUCTORS AMPACITY CONDUCTORS e IN RACEWAY 310.15(B)(3)(a) IN RACEWAY PROJECT# NA DATE DRAWN 9'2612024 4 12 SKU: Q-12-RAW-300, THHN DRAWN BY E.Rv-a.D 1 g THWN-2 BARE COPPER-(GROUND) A N/A FREE AIR 30 90° 11.97 0.96 0.8 23.04 14.96 SHEET# P TITLE THWN-2 COPPER-(L1,L2) B 3 10 3/4" PVC 40 90° 23.94 0.96 1 38.40 29.93 ELECTRICAL 3LD 1 8 THWN-2 COPPER-(GROUND) BACKFEED BREAKER SIZING OF NE MAX. CONTINUOUS OUTPUT 1.33A @ 240V ELECTRICAL EQUIPMENT LIST METER N0. 98385525 � !ti y0 23.94 X 1.25 = 29.93AMPS 30A BREAKER-OK S.NO. ITEMS DESCRIPTION QTY. ACCOUNT NO.# 9676059104 ��Q' p��MAN�'Qy SEE 705.12 OF 2017 NYSEC JINKO SOLAR * t C= 1 PV MODULE 18 JKM425N-54HL4-B D W 200 IX 1 1.20 1240 240 200 = 40AALLOWABLE BACKFEED 2 MICROINVERTER ENPHASE IQ8MC-72-M-US 18 2 0�128 ENPHASE IQCOMBINER ��� CTRIO 3 COMBINER 1 5/5C (E) UTILITY METER TO UTILITY AROFESS10r1P�' GRID STAMPED 09/26/2024 3 (N) ENPHASE (E)200A RATED THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW.REPRODUCTION IN COMBINER BOX MAIN SERVICE PANEL ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT 1 PH, 120/240V 60HZ U PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. (E)200A/2P MAIN CELL WIRE LESS BREAKER Current �.� MODEM COMMS (TOP FED) ; , ^ Rene -Was 45 Engineering IQ GATEWAY CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Street,Bidg 2 Rivemide,CA 92501 1 Email:Projects@creng.solar reng A (N)15A_�_ • • co 951�215635 2 CONTRACTORINFO ' TO OTHER •�• 1 BRANCH OF 9 LOAD ®n PV MODULE N• (N)20A .�' CZSYSs. m •�• ELEMENT ENERGY LLC. (N)20A 7470 SOUND AVENUE,MATiITUCK, • NEW YORK,11952 PH:(631)779 7993 services@e2sys.com • • Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 2 BRANCH OF 9 (SUFFOLK HOME IMPROVEMENT) PV MODULE ANV NICHOLAS SOURBIS 200 GREEN HILL LN, GREENPORT, NY 11944 B N AHJ TOWN OFSOUTHOLD MODULE JINK050LAR ( ) 30A 2P MANUFACTURER / PV LONG ISLAND POWER AUTHORITY BREAKER UTILITY (E)GROUNDING ELECTRODE _ (LIPA) MODULE MODEL JKM425N-54HL4-B CONDUCTOR #6 BARE COPPER PV SUMMARY SYSTEM SIZE STC 425 X 18 = .650 MODULE(W) 425 (KWoc) PTC 398.1 X 18 = .166 MODULE PTC(W) 398.1 SYSTEM SIZE (KWAC) : 5.76 @240 MODULE Isc(A) 13.58 1INKO SOLAR NOTE: MODULES : 18 1KM425N-54HL4-B MODULE Voc IV) 38.95 1)CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS MICROINVERTER 18 ENPHASE MODULE Imp(A) 13.13 AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. QSMC-72-M-Us 2)ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8"ABOVE ROOF WITH MODULE Vmp(V) 32.37 PROPER JUNCTION BOX AT EACH END PER 690.31A WIRE CALCULATION STARTING ADJUSTMENT MAXIMUM Rev Description Date STARTING TEMPERATURE FACTOR FOR ADJUSTED CURRENT D INITIAL DESIGN 9/2s/zo2a CURRENT CONDUCTOR CONDUCTOR CONDUIT ALLOWABLE TEMPERATURE CORRECTION MORE THAN 3 CONDUCTOR APPLIED TO TAG DESCRIPTION APPLIED TO FACTOR A QTY. SIZE (AWG) SIZE&TYPE AMPACITY RATING (°C) CONDUCTORS CONDUCTORS AMPACITY CONDUCTORS e 310.15(B)(16) IN RACEWAY 310.15(13)(2)(a) 310.15(B)(3)(a) IN RACEWAY PROJECT. NA DATE DRAWN 9/2612024 4 12 SKU: Q-12-RAW-300, THHN DRAWN BY E.R A N/A FREE AIR 30 90° 11.97 0.96 0.8 23.04 14.96 SHEET# PV-4.1 1 8 THWN-2 BARE COPPER-(GROUND) TITLE 3 10 THWN-2 COPPER-(L1,L2) g 3/4" PVC 40 90° 23.94 0.96 1 38.40 29.93 ELECTRICAL SLD 1 1 8 THWN-2 COPPER-(GROUND) EXISTING SERVICE PANEL PHOTOS �<1- 0f NEW M i49 O�'� D w m 099128 L ZN�O CTRIc ARo�SS1 STAMPED 09/26/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW. REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current n Engineering CURRENT RENEWABLES ENGINEERING INC. 3600 Llme Street.Bing 2 Ri—cle.CA 92501 Email Prolects@creng solar Websde www.—ogm PHONE.(951)-215-6354 CONTRACTORINFO A ® n S CZSYSU ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 • services@e2sys.com Licence-ME-52689 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) NICHOLAS SOURBIS 200 GREEN HILL LN, GREENPORT, NY 11944 AHJ TOWN OFSOUTHOLD LONG ISLAND POWER AUTHORITY UTILITY (LIPA) j PV SUMMARY SYSTEM SIZE(KWDC) STC 425 X 18 = 650 i PTC 396.1 X 18 = 166 V SYSTEM SIZE 5 76 @240 (KWAC) MODULES 18 11NKO SOLAR 1 KM425N-54HL4-B VICROINVERTER 18 ENPHCAE 108MC-72-M-US Rev Description Date 0 INITIAL DESIGN 9/26/2024 A LN 9/26/2024 E.R PV-4.2 TITLE ELECTRICAL PHOTOS MATERIAL LIST ��°f MNEwy �,�P p�E ELECTRICAL EQUIPMENTS QTy• PART TYPE PART NUMBER DESCRIPTION 2� 099128 18 MODULE JKM425N-54HL4-B JINKO SOLAR JKM425N-54HL4-B Fa CTR1r- 18 MICROINVERTER IQ8MC-72-M-US ENPHASE IQ8MC-72-M-US ss►oNP�' 1 COMBINER X-IQ-AM1-240-5/5C Enphase IQ Combiner 5/5C STAMPED 09/26/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. 3Current +A eneables Engineering CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Street,Bldg 2 Riverside,CA 92501 Email:Pmjecls@creng.solar Websife:va creng.co PHONE: 951 215-6354 CONTRACTORINFO di ©� BREAKER/ FUSES CZSYS QTy• PART TYPE PART NUMBER DESCRIPTION ELEMENT ENERGY LLC. 1 BREAKER 30A 2-POLE BREAKER(S) -GENERAL 30A 2-POLE BREAKER(S) 7470 SOUND AVENUE,MATTITUCK, NEW YORK,11952 PH:(631)779 7993 2 COMBINER BREAKER 20A 2-POLE BREAKER(S) GENERAL 20A 2-POLE BREAKER(S) services---ME-E-52689669 (MASTER ELECTRICIAN) Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) _ NICHOLAS SOURBIS 200 GREEN HILL LN, GREENPORT,NY 11944 AHJ TOWN OFSOUTHOLD RACKING QTy• PART TYPE PART NUMBER DESCRIPTION UTILITY LONG ISLAND POWER AUTHORITY (LIPA) PV SUMMARY 12 RAILS & SPLICES XR-100-168B XR100, RAIL 168" CLEAR SYSTEM SIZE(KWDC) STC 425 X 18 = .650 6 RAILS & SPLICES XR100-BOSS-01-B1 BONDED SPLICE, XR100 PTC 398.1 X 16 = .166 SYSTEM SIZE 5 76 @240 42 CLAMPS & GROUNDING UFO-CL-01-B1 UNIVERSAL MODULE CLAMP, BLACK (KWAC' IN KO MODULES 18 1.425OLAR JKM425N-54HL4-B 12 CLAMPS & GROUNDING UFO-STP-40MM-B1 STOPPER SLEEVE 40MM BLACK QBMAC-S2-M-U5 MICRDINVERTER 16 3 CLAMPS & GROUNDING XR-LUG-03-Al GROUNDING LUG, LOW PROFILE 37 ATTACHMENTS QM-HUG-01-B1 HALO UKTRA GRIP, BLACK 74 ATTACHMENTS BHW-SQ-02-Al SQUARE-BOLT BONDING HARDWARE Rev Description Date O INITIAL DESIGN 9/26/2024 A B LDRAWN NA 9/2 612 02 4 E.R PV-5.0 TITLE BOM CAUTION �C�OF M NElvy0 ,r;Q' MULTIPLE SOURCE OF POWER n A 0 g D W 099128 PHOTOVOLTAIC SYSTEM, EQUIPPED ■ID SHUTDOWN PV ARRAY N CTRIGP�' !� � ARO�ss►oNP�" 690.12 STAMPED 09/26/2024 THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT TURN RAPID DISCONNECT z PRIOR WRITTEN ABLESEAPPROVAL ENGINEERING CURRENT J RENEWABLES ENGINEERING INC. J SHUTDOWN SWITCH TO RATED AC OUTPUT CURRENT - 23.94AMPS' THE "OFF" POSITION TO AC •' ' • ' • 1 • z - } CRenewables urrent LU SHUT DOWN PV SYSTEM 690.14,690.15,690.54 Engineering AND REDUCE SHOCK . CURRENT Lime S reef BlBdg 2 Riveerside,CA 9R21501 INC. HAZARD IN THE ARRAY Email:Pmjects@creng.solar POWERDUAL • ■ HONE:Website:5.1.5 SECOND g.w 690.56(C)(1)(B) SOURCE ■ PHOTO- • • VOLTAIC CONTRACTOR INFO FA RATED AC OUTPUT CURRENT - 23.94 AMPa AC NORMALOPERATING • ' 1 VOLTS 690.54 E 2 SYSI - OPTIONAL SOLAR LOAD CENTER ELEMENT AVENUE, LLC. asw 74T0 SOUND AVENUE,MATTITUCK, ARRAY c w^ NEWYORK,11952 PH:(631)31)77 779 7993 MAIN SERVICE PANEL services@e2sys.com COMBINER Licence-ME-52689 (MASTER ELECTRICIAN) UTILITY METER Licence-HI-67461 (SUFFOLK HOME IMPROVEMENT) 7 P �B PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL NICHOLAS SOURBIS PANEL IS AC DISCONNECT PER NYSEC690.17 200GREEN HILL LN, L _ GREENPORT, NY 11944 INVERTER OUTPUT • • AHJ TOWNOFSOUTHOLD • • RELOCATE THIS I LONG ISLAND POWER AUTHORITY NEC 690.31(G)(3)&(4),CRC R324.7 UTILITY (LIPA) • DEVICE . PV SUMMARY (UNLESS BUSBAR IS FULLY RATED) L — (KWDC)SYSTEM SIZE STC 425 X 18 = .650 PHOTOVOLTAIC POWER SOURCE PTC 396.1 X 18 = .166 705.12(D)(2) SYSTEM SIZE (KWAC) : 5.76 @240 EVERY 10'ON CONDUIT AND ENCLOSURES MODULES 18 1 INKO425N-54 1KM425N-54HL4-B MICROINVERTER 1g ENPHASE 1Q8MC-72-M-US NOTES: 1. NYSEC ARTICLES 690 AND 705 AND NYSEC SECTION R324 MARKINGS SHOWN HEREON. 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: Rev Description Date A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR 0 INITIAL DESIGN 9/26/2024 MACHINE PRINTED LETTERS OR ELECTRO-PLATING. A B. RED BACKGROUND COLOR WHITE TEXT AND LINE B WORK. PROJECT# NA C. AERIAL FONT. DATE DRAWN 912612D24 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN DRAWN BY E.R THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE SHEET# PV-s.o HAND-WRITTEN. TITLE 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH SIGNAGE POP-RIVETS OR SCREWS. _ ° ENGINEERING DRAWINGS MECHANICAL CHARACTERISTICS Front Side Back No.of Half Cells 108(2 x 54) , E A GaL,E 1134 4665I 1086..61.68' - _; Dimensions 1722 x 1134><35mm 167.79.44.65 x 1.38 inch) " ,fM 0 OUa L - a Weight `- 22.Okg(48.51bs) . HE ! s ipi t ,I , a FronlGlass 3.2mm,Anti-Reflection Coating 0ST +"� k Ry T -�Fir aL High Transmission,LOW Iron,Tempered Glass THESE DRAWINGS ARE SUBJECTTO COPYRIGHT � • n i PROTECTION BY US LAW.REPRODUCTION IN i , I Frame Anodized _ _ a __ _ _ ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT ( ��9k i I DEPENDABLE - _ _ r i - PRIOR WRITTEN APPROVAL FROM CURRENT i Junction Box IP68 Rated - RENEWABLES ENGINEERING INC. e `� >t! s 't u _� U , + `!! �' Output Cables 12 AWG,1400mm(55.12in)or Customized Length a t _ _. _ Connector Staubli MC4SOLAR PRODUCT Curr ent I Fire Type _ __Type 1 Pressure Rating 540OPa[Snow)&240OPa(Wind) R ene w bl es i Engineering EAGLE 54HITI66 a x. �_ TEMPERATURE CHARACTERISTICS CURRENTmStmeABLESENGe,CA92NGINC. 360D Lim Sue Projec 2 Riverside, r 92501 Email:Projeds@crengsolar 420-440 WATT • N-TYPE TOPCON ----`- - mm --- - - - -- -- --- __ --- - --- Le the t 2 Temperature Coefficients of Pmax 0 29%/•C ebs°e:w .cmng.co I ' -_- _i _ -_ PHONE 95t 215 6354 I Width:±2mm Temperature 0.25%/°C Positive power tolerance of 0-+3% Height: Temperature Coefficients of 0045%/°C CONTRACTORINFO Row Pitch: I Nominal Operating Celt Temperature(NOCT) 45 2°C • e .+ a21 NYSE-listed since 2070,Bloomberg Tier 1 manufacturer "- • Top performance in the strictest 31 party labs ELECTRICAL PERFORMANCE&TEMPERATURE DEPENDENCE MAXIMUM RATINGS E2YS�S • Automated manufacturing utilizing artificial intelligence Current-VoLtage&Power-Voltage Temperature Dependence Operating Temperature[ICI -40°C-a85°C ___ ______ ELEMENT ENERGY LLC. Curves(440W1 of Isc,Voc,Pmax i Maximum System Voltage y - 1000VOC 7470 SOUND AVENUE,MATrITUCK, • Vertically integrated,tight controls on quality ,, y 9 NEW YORK,11952 16 Maximum Series Fuse Rating 25A PH:(631)779 7993 • Premium solar factories in USA,Vietnam,and Malaysia 6 _ >� m services@e2sys.com Licence-ME-52689 a in .l ; ,so (MASTER ELECTRICIAN) KEY FEATURES - -- p Licence-OMEI IMPROVEMENT) '�.` 67461 e s _ .. . z,o� � m� (SUFFOLK HOME IMPROVEMENn e,m PACKAGING CONFIGURATION Superior Aesthetics [Twopallets=OnestackJ - --'- �^ --_t NICHOLAS SOURBIS ( Black backsheet and black frame create ideal Look for ° ° E 60 31pcs/pallets,62pcs/stack,806pcs/40 HQ Container residential applications. ° ° 0 Voltage IV) 35 200 GREEN HILL LN, zo GREENPORT,NY 11944 N-Type Technology N-type cells with Jinko's in-house TOPCon technology S WARRANTY AHJ TOWN OF SOUTHOLD Celt Temperature!°c1 offers better performance and improved reliability. ear 25- product and 30- ear Linear owerwarrant Y P y P Y UTILITY LONG ISLAND POWER AUTHORITY G Thick and Tough 1"year degradation not to exceed 1%,each subsequent year not to (UPA) Fire Type 1 rated module engineered with a thick frame, exceed 0.4%,minimum power at year30 is 87.4%or greater. PVSUMMARY3.2mm front side glass,and thick backsheet for added durability. SYSTEM SIZE (KWDC) STC 425 x 18 = .650 SYSTEM SIZE Shade Tolerant ELECTRICAL CHARACTERISTICS PTc 39e.1 x 1s = .166 t - --0 Twin array design allows continued performance Module Type JKM420N-54HL4-B JKM425N-54HL4-B JKM430N-54HL4-B JKM435N-54HL4-B JKM440N-54HL4-B (KWAC) 5.76 @240 \ __ __ _ _ _ _ JINKO SOLAR even with Shading by trees Or debris. ` ' STC NOCT STC NOCT- STC NOCT STC NOCT STC NOCT MODULES 18 I JKM425N-54HL4-B Protected Against All Environments Maximum PowerlPmax) 420Wp 316Wp 425Wp 320Wp 430Wp 323Wp 435Wp -327Wp -v 440Wp --331Wp MICROINVERTER 18 ENPHASE ` --- - ------ - -_._ ICBMC-72-10-US Certified to withstand humidity,heat,rain,marine environments, I Maximum Power Voltage(Vmpl W 32.16V 29.95V 32.37V 30.1W 32.58V 30.30V - 32.78V 30.50V 32.99V 30.73V wind,hailstorms,and packed snow. Maximum Power current limp) 13.06A 10.55A 13.13A 10.60A 13.20A 10.66A 13.27A 10.72A 13.34A 10.77A Warranty Open-circuit Voltage(Vac) _ -- 38.74V 36 80V- - 38.45V 37.00V - 39.16V 37.20V 39.36V 37.39V -34 57V' --37.59V 25-year product and 30-year Linear power Warranty. Short-circuit Current Rscl 13.51A 10 91A 13.58A 10.96A 13.65A 11.02A 13.72A 11.08A 13 80A 11.14A Module Efficiency STC(%) 21.51% 21.76%- �22.02% 22,28% 22.53% Rev Description Date , 0 INITIAL DESIGN 9/26/2024 'STC: ;®;Irradiance 1000W/m2 Cell Temperature 25°C � AM=1.5 • IS09001:2015 Quality Standards • IS045001:2018Occupational Ad, V `'�_� NOCT:;®;Irradiance 800W/m2 ' Ambient Temperature 20°C Q AM=1.5 �Wind Speed lm/s A IS014001:2015EnvironmentalStandards Health&Safety Standards CE C •L S B IEC61215,IEC61730 certified products UL61730 certified products In 'Power measurement tolerance:33% LISTED PROJECT# NA The companyreserves the final right forexplanation onany of the information presented hereby.JKM420-440N-54HL4-B-F1-US S'Q DATE DRAWN 9/262024 • BUILDING YOUR TRUST IN SOLAR.WWWJINKOSOLAR.US �nK0 DRAWN BY E.R BUILDING YOUR TRUST IN SOLAR.WWW.JINKOSOLAR.US finK® SHEET# PV-7.0 TITLE MODULE SPEC ENPHASE. �01 IQBMC Microinverter INPUT DATA(DC) UNITS 108MC-72-M-US Commonly used module pairings W 260-460 j } To meet compatibility,PV modules must be within the following max.input DC voltage and max.module Ir wModule compatibility Module compatibility can be checked at http3://enphase com/installers/microinverters/caL-ulartor. i i - _ THESE DRAWINGS ARE SUBJECT TO COPYRIGHT ' MPPT Volta a ran 6 V 25-45 PROTECTION BY US LAW.REPRODUCTION IN 9 g .-- � ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT I I V 18-58 PRIOR VN APPROVAL FROM CURRENT Operating range RENEWABEWABLES ENGINEERING INC. 1 ' Min./Max.start voltage V 22/58 Max.input DC voltage -V 60 Current ; Max.continuous operating DC current 14 A R e e a l e s a Max.input DC short-circuit current A 25 Engineering ing Max.module I," A 20 I — CURRENT RENEWABLES ENGINEERING INC. I Overvoltage class DC port ' 11 3600 Lime Stmet,Bldg 2 Riverside,CA 92501 Emil:Pmjeds@aengsolar DC portbackfeed current MA O Websile:www.creng.co PHONE: 951 215-6354 PV array configuration Ungrounded array,no additional DC side protection required;AC aide protection requires max 20 A per branch circuit \ OUTPUT.. . CONTRACTORINFO I Peak output power VA 330 315 Max.continuous output power j VA i 320 i 310 aur -' - -- - ['Nominal grid voltage(L-L) V 240,split-phase(L-0,180° 208,single-phase(L-L),120° I S0 IQ8MCMicroinverter Easy to install u.. ! Min./Max.grid voltage'. - -= .-- 211-264_.,._ _ _ .__ _.:_�__...._ .- ._ _-163-229_ _.-... __ _ C� -- Our newest IQS Series Microinverters are the indusY s first micro rid FQrmin •,software Lightweight and compact with plug- Max.continuous output current A 133 1'49 ELEMENT ENERGY LLC. ry g g and-play connectors I ? { 7470 SOUND AVENUE,MATTITUCK, defined microinverters with split-phase power conversion capability to convert DC power to Nominal frequency I Hx 60 NEW YORK,11952 AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary Power line communication(PLC) Extended frequency range Hz 47 66 PH.(631)779 7993 application-specific integrated circuit(ASIC),which enables the microinverter to operate in between componerns s9 `� 9 services@e2sys.com grid tied or off-grid modes.This chip is built in advanced 55-nm technology with high-speed AC short circuit fault current over three Licence-ME-62689 • Faster installation with simple two-wire A_ 2.70 (MASTER ELECTRICIAN) digital logic and has superfast response times to changing loads and grid events,alleviating cabling cycles I Licence-HI-67461 constraints on battery sizing for home energy systems — ----------------__.—_ _. _ _—..__. _------.._.___._�._—-- ___-.� __.—___-V--- ---.—__ Max.units per 20 A(L-L)branch circuit 3 12 10 (SUFFOLK HOME IMPROVEMENT) i High productivity and reliability Total harmonic distortion % <5 �. _—� Produces power even when the grid is _._ __ _-_... _ __.- _ ____-i. _ ._!_ ._-___—.-_�-._--_.---.._--._-._____ ___..-______._--_...____ __ __.__.. __..___ _ _.__ N I C H O LAS SOUR B IS down* I Overvoltage class ACport III 200 GREEN HILL LN, More than one million cumulative hours ! AC port backfeed current mA 16 REENPORT,NY 11944 G ' of testing l Power factor setting 7.0 AHJ TOWN OFSOUTHOLD Class II double-insulated enclosure Part of the Enphase Energy System, IQ8 Series Microinverters redefine Grid-tied power factor(adjustable) 0.85 leading_.0.85 lagging IQ8 Series Microinverters inte rate with reliability standards with more than one Optimized LONG ISLAND POWER AUTHORITY g ty ptUTILITY the IQ Battery,IQ Gateway,and the million cumulative hours of power-on PV modules Peak efficiency % 97.4 972 (LIPA) Enphase App monitoring and analysis testing,enabling an industry-leading CEC we ghted efficiency { % 97.0 96.5 PV SUMMARY software. limited warranty of up t0 25 years. ! _. __ __. -_ _ ._ _._ [(K STEM SIZE _ Mlcrogrid-forming Nighttime power consumption mW 33 25 WDC) S : STC 425 X 18 .650 Complies with the latest advanced grid IMECHAPTC 396.1 X 16 = .166 .� Support DATA" -40°C to 65°C(-40•F to 149°F) ACM SIZE 5.76 @240 i Ambient temperature range Remote automatic updates for the JINKO SOLAR I latest grid requirements Relative humidity range j J 0%(condensing) DULES 18 _ ,NPHASE 54HL4 4%to 10 -B ,. Configurable to support a wide range i DC connector type StaubiMC4 CROINVERTER 18 QBMC-72-M-US of grid profiles Dimensions(H•W.D);Weight i 212 mm(8 3) 175 mm(6.9")•30.2 mm(1.2");11 kg(2.43 Ibs) Connect PV modules quickly and easily I08 Series Microinverters are UL Listed -- -- ---- ---_..___. t _.____.__ ___ .__ _._______ ___.__ __ _ _-_-__ to the IQ8 Series Microinverters that have as PV rapid shutdown equipment and Meets CA Rule 21(UL 1741-SA)and IEEE Cooling Natural convection-no fans integrated MC4 connectors. conforms with various regulations when 1547:2018(UL 1741-SB) Approved for wet locations;Pollution degree Yes;PD3 installed according to the manufacturer's ; i Enclosure Class 11 double-insulated,corrosion-resistant polymeric enclosure Instructions. NOTE: ` Environ.category;UV exposure rating i NEMA Type 6;outdoor IQ8 Microlnverters cannot be mixed together with Rev Description Date previous generations of Enphase microinverters COMPLIANCE 0 INITIAL DESIGN 9/26/2024 (107 Series,IQB Series,etc.)in the sae system.m • IQ Gateway is required to change the default grid ! CA Rule 21(UL1741-SA).UL 62109-1,IEEE 15472018(UL 1741-SB),FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 'Meets UL1741 only when installed with IQ System Controller and 3, profile at the time of Installation to meet the local I Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017,NEC 2020,and NEC 2023 section 690.12 and A Authority Having Jurisdiction(AHJ)requirements. L— C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's instructions. B PROJECT# NA 0 2023 Enphase Energy.All rights reserved.Enphase,the a and CC logos,ICI and certain other marks listed at � /� (1)No enforced DC/AC ratio. httpsJ/enphasamm/tmdemark-usa-ge-nuidelJnesaretmdemarksof Enphase Energy,Inc.inthe USandothercountries. (2)Nominal voltage range can be extended beyond nominal if required by the utility. IQBMC-MC4-DSH-00049-3A-EN-US-2023-10-18 DATE DRAWN g/26/202q Data subject to change. I08MC-MC4-DSH-00049-3.0-EN-US-2023-10-18 (3)Limits may vary.Refer to local requirements to define the number of microinvertem per branch in your area. DRAWN BY E.R SHEET# PV-7.1 TITLE MICROINVERTER SPEC ENPHASE. IQ Combiner 5/5C MODEL NUMB_ER IQ Combiner 5 with IQ Gateway printed circuit board for integrated revenue-grade PV j IQ Combiner 5(XAQ-AM1-240-5) production metering(ANSI C1220±0.5%),consumption monitoring(±2.5%),and IQ Battery monitoring(±2.5%).includes a silver solar shield to deflect heat. i IQ Combiner 5C with IQ Gateway printed circuit board for integrated revenue-grade b ENPHASE i i PV production metering(ANSI C1220±0.5%),consumption monitoring(±2.5%),and IQ Combiner 5C(X-I0-AM1-240-5C) IQ Battery monitoring(±2.5%),Includes Enphase Mobile Connect cellular modem (CELLMODEM-Ml-O6-SP-05)'.Includes a silver solar shield to deflect heat. THESE N ARE SUBJECT TO COPYRIGHT Y' PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT i , PRIOR WRITTEN APPROVAL FROM CURRENT WHAT'S IN THE B o RENEWABLES ENGINEERING INC. IQ Gateway is the platform for total energy management for comprehensive,remote IQ Gateway printed circuit board maintenance,and management one IQ Gateway breaker and four 20 A breakers for t of the Enphase Energy System _ Current 80 A busbar with support for o � Busbar installing IQ Series Microinverters and IQ Battery 5P enevva b e 1 { IQ Gateway breaker Circuit breaker,2-pole,10 A/15 A Engineering X-I0-AM1-240-5 Production CT Pre-wired revenue grade solid-core CT,accurate up to±0.5% CURRENT RENEWABLES ENGINEERING INC. " X-1Q-AM7-240-5C Consumption CT Two consumption metering clamp CTS,shipped with the box,accurate up to±25% 3600 Lime Street,Bidg 2 Riverside,CA 92501 Email:Projects@crengsolar Website:w .creng.co IQ Battery CT One battery metering clamp CT,shipped with the box,accurate up to±2 5% PHONE 951 215-6354 CTRL board Control board for wired communication with IQ System Controller 3/3G and the CONTRACTOR INFO ry SID IQ Combiner 5/5C - 4G-baIQ sed Smart Enphase Mobile Connect(only with IQ Combiner 5C) 4G-based LTE-M1 cellular modem(CELLMODEM-Mt-06-SP-05)with a 5-year T-Mobile data plan The IQ Combiner 5/5C consolidates interconnection equipment into a single enclosure and streamlines IQ Series Microinverters and IQ Gateway installation by providing a consistent, Includes IQ Gateway for Pre-wired solution for residential applications.IQ Combiner 5/5C uses wired control communication and control Accessories kit Spare control headers for the COMMS-KIT-2 board CP SYSO communication and is compatible with IQ System Controller 3/3G and IQ Battery 5P. Includes Enphase Mobile Connect ACCESSORIES AND REPLACEMENT PARTS (NOT INCLUDED, O• DER SEPARATELY) (CELLMODEM-Mt-06-SP-05),only The IQ Combiner 5/5C,IQ Series Microinverters,IQ System Controller 3/3G.and with IQ Combiner 5C CELLMODEM-MI-O6-SP-OS 4G based LTE-M7 cellular modem with a 5-year T-Mobile data plan ELEMENT ENERGY LLc. IQ Battery 5P provide a complete grid-agnostic Enphase Energy System. 747o SOUND AVENUE,MArnTucK, • Supports flexible networking:W'rFi, CELLMODEM-MI-06-AT-O5 4G based LTE-Ml cellular modem with a 5- ear AT&T data Ian y P NEW YORK,11952 Ethernet,or cellular - Su orts Eaton BR2XX,Siemens Q2XX,and GE/ABB THOL21XX Series circuit breakers Mcencs-ME-52689 Supports Licence-ME-52689 Provides production metering Circuit breakers(off-the-shelf) (XX represents 10,15,20,30,40,50,or 60).Also supports Eaton BR22OB,BR230B,and (MASTER ELECTRICIAN) (revenue grade)and consumption BR240B circuit breakers compatible with the hold-down kit. Licence-HI-67461 g (SUFFOLK HOME IMPROVEMENT) monitoring i- - BRK-10A-2-240V,BRK-15A-2-240V,BRK-20A-2P-240V,BRK-15A-2P-240V-B,and Circuit breakers(provided by Enphase) BRK-20A-2P-24OV-B(more details in the Accessories"section) Easy to install - NICHOLAS SOURBIS XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner IQ Series Microinverters IQ System Controller 3/3G Mounts to one stud with centered } - 200 GREEN HILL LN, The high-powered smart grid-ready IQ Series Provides microgrid interconnection device brackets XA-ENV2-PCBA-5 IQ Gateway replacement printed circuit board(PCB)for IQ Combiner 5/5C G REEN PORT,NY 11944 Microinverters(106,IQ7,and IQ8 Series) (MID)functionality by automatically detecting Supports bottom,back,and side X-I0-NA-HD-125A Hold-down kit compatible with Eaton BR-B Series circuit breakers(with screws) simplify the installation process. grid failures and seamlessly transitioning conduit entries AHJ TOWN OFSOUTHOLD the home energy system from grid power to XA-COMMS2-PCBA-5 Replacement COMMS-KIT-2 printed circuit board(PCB)for IQ Combiner 5/5C backup power. Supports up to four 2-pole branch UTILITY LONG ISLAND POWER AUTHORITY circuits for 240 VAC plug-in breakers (LIPA) _. (not included) Rating 80 A PV SUMMARY 80 A total PV branch circuits FMICROINVERTER 1:1System voltage and frequency 120/240 VAC or 120/208 VAC,60 Hz STC 425 X 18 = .650 Bluetooth-based Wi-Fi provisioning PTC 398.1 X 18 = .166 for easy Wi-Fi Setup Busbar rating 125 A 5.76 @240 - Fault current rating 10 kAIC I NKO SOwR Reliable 18 IKM425N-54HL4-B Maximum continuous current rating 4 A8 ENPHASE -- 6 IQ Battery 5P IQ Load Controller Durable NRTL-certified NEMA type 3R (input from PV/storage) IQSMC 72 M US enclosure Fully integrated AC battery system.Includes Helps prioritize essential appliances during a i Up to four 2-pole Eaton BR,Siemens Q,or GE/ABB THQL Series distributed generation six field-replaceable IQ8D-BAT Microinverters. grid outage to optimize energy consumption 5-year limited warranty Branch circuits(solar and/or storage) (DG)breakers only(not included) and prolong battery life. 2-year labor reimbursement program Maximum total branch circuit breaker rating(input) 80 A of distributed generation/95 A with IQ Gateway breaker included coverage included for both the IQ Combiner SKUs IQ Gateway breaker 10 A or 15 A rating GE/Siemens/Eaton included _ , �•r - - - _ - r UL7741 Listed ^' Production metering CT 200.A solid core pre-installed and wired to IQ Gateway Rev Description Date � i 0 M, y li 0 INITIAL DESIGN 9/26/2024 a Consumption monitoring CT(CT-200-CLAMP) ; A pair of 200 A clamp-style current transformers is included with the box 0 A � IQ Battery metering CT 200 A clamp-style current transformer for IQ Battery metering,included with the box B 5-year limited warranty PROJECT# NA DATE DRAWN 9/26/2024 *For country-specific warranty information,see the https✓/enphase.comfinstallers/resources/warranty page 'A plug-and-play industrial-grade call modem for system of up to 60 microlmrertere.Available In the United States,Canade,Mexico,Puerto Rico,and the US Virgin Islands,wherethere lsa equate DRAWN BY E.R 02024 Enphase Energy.All rights reserved.Enphase,the a and CC logos,IQ and certain other marks listed at cellular service In the installation area. SHEET# PV-7.2 httpw//enphwo.com/trademark-usage-quidelinm ere trademarks of Enphase Energy,Inc.in the US.and other countries. Data subject to change. IOC-5-5G-DSH-00007-5D-EN-US-2024-08-16 IOC-S-SC-DSH-00007-5.0-EN-US-2024-08-10 TITLE COMBINER SPEC ,COL IRON RIDGE XR Rail° Family XR Rail° Family The XR Raila Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads,while minimizing material costs. Depending on your location,there is an XR Rail®to match. Solar Is Not Always Sunny Over their lifetime,solar panels experience countless T THESE DRAWINGS ARE SUBJECT TO REPRODUCTION IN COPYRIGHT .�s�-`"" PROTECTION BY US REPRODUCTION IN _ _ ,�* ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT extreme weather events. Not just the worst storms in years, - - -" " �` PRIOR WRITTEN APPROVAL FROM CURRENT but the worst storms in 40 years. High winds capable of y _ RENEWABLES ENGINEERING INC. ripping panels from a roof,and snowfalls weighing -_ r-- enough to buckle a panel frame. - - --�.;:., Y =`" �-�=-�.:,; ;� _ ' urrent Renevvabtes XR Railso are the structural backbone t- `® preventing these results.They resist uplift, ' � XR10 XR100 xRi000 �� Engineering �r 'e� protect against buckling and safely XR10 is a sleek,low-profile mounting XR100 is a residential and commercial XR1000 is a heavyweight among CURRENT RENEWABLES ENGINEERING INC- and efficiently transfer loads into the rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle 3600 Lim SV:Pmije g 2 Riverside, r 92501 .w no snow.it achieves spans u to 6 feet, wind and snow conditions.while also extreme climates and spans up to 12 Email: fte: .ceng.olar building structure.Their superior p p Webs e:wvm.c2ng,co spanning Capability requiresitsup fewer while remaining 1(ght and economical. maximizing spans up to 10 feet feet for commercial applications. PHONE: 951}215-6354 ;;, roof attachments,reducing the 6'spanning capability 10'spanning capability 12'spannjng capability CONTRACTOR INFO f '.�. Moderate load capability Heavy load capability Extreme load capability number of roof penetrations f-� Clear&black anodized finish Clear&black anodized finish Clear anodized finish and the amount of *' I Internal splices available Internal splices available internal splices available installation time. - - ~ ;:` aur — " CZSYS0 Rail Selection - I *^, t ELEMENT ENERGY LLC. ±, ` g The table below was prepared In compliance with applicable engineering% Codes and Standards. Values are 747o SOUND AVENUE,MATTITUDK, t I 52 based on the following criteria:ASCE 7-16,Gable Roof Flush Mount, Roof Zones 1 &2e, Ex osure B, Roof NEWPORK,fl99 P PH:(631)779 7993 Slope of 8 to 20 degrees and Mean Building Height of 30 ft.Visit IronRidge.com for detailed certification letters. services@e2sys.com Licence-ME-52689 (MASTERELECTRICIAN) -HII-67N)461 (SUFFOLK HOME IMPROVEMENT) 4 8 1 _ NICHOLAS SOURBIS Force-Stabilizing Curve 90 200 GREEN HILL LN, Sloped roofs generate both vertical and lateral 120 GREENPORT,NY 11944 forces on mounting rails which can cause them to None - bend and twist.The curved shape of XR Rails® 140 XR10 �XR1 XR10� AHJ TOWN OF SOUTHOLD � is s ecially designed to increase strength in both directions while resisting the twisting.This unique LONG ISLAND POWER AUTHORITY feature ensures greater security during extreme 160 .gy I UTILITY fLIPAl weather and a longer system lifetime. 90 PV SUMMARY SYSTEM SIZE STC 425 X 18 - .650 120 (KWDC) .i PTC 398.1 X 16 = .166 20 i SYSTEM SIZE 140 - - (KWAC) : 5.76 @240 MODULES 18 11N KO SOLAR 160 1KM42SN-54HL4-B 90 PHAE MICROINVERTER 18 IQSMC572-M-US 30 160 Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials gp i I XR RailsO are IronRidge®offers All XR Rails@ are made of 6000-series 40 i I compatible with ® ® a range of tilt leg aluminum alloy,then protected with an 160 FlashFoot®and options for flat anodized finish.Anodizing prevents surface Rev Description Date ® other pitched roof ® roof mounting and structural corrosion,while also providing '` 80 160 D INITIAL DESIGN 9/2 612 02 4 attachments. applications. a more attractive appearance. �'!�` "" , A 120 160 'Table Is meant to be a simplified span chart for conveying general rail capabilities.Use approved certification letters for actual design guidance. PROJECT# NA DATE DRAWN 9/26/2024 mil on.° .°,' 1, DRAWN BY E.R ®� SHEET# PV-7.3 TITLE RAIL SPEC ZAL IRONRIDGE QuiCkMount' Adaptive, Rafter-Friendly Installation The Respect Your Roof Deserves THESE DRAWINGS ARE SUBJECT TO COPYRIGHT When integrating with a home,solar attachments _ r t � � { PROTECTION BY US LAW.REPRODUCTION IN must be dependable for the lifetime of the rooftop. __ . ANY FORM I EXPRESSLY FORBIDDEN WITHOUT ' � �� PRIOR WRITTEN APPROVAL FROM CURRENT Due to recent innovations, many asphalt shingles _ RENEWABLES ENGINEERING INC. have bonded courses.A mount that protects without ! ----- = I + wrn, �� �• — " ,��P �. the need to pry shingles can really speed things up. A • Current_g Halo UltraGrip (HUG )is here to respect the roof. Its Halo is a cast-aluminum barrier that encases the UltraGrip,our industrial-grade,foam-and-mastic e CURRENT RENEWABLES ENGINEERING INC. seal.This allows HUG to accelerate the installation 3500 Lime Street,Bldg 2 Riverside,CA 92501 Email:Pmjecls@creng solar process and provide the utmost in waterproofing Website:viww.cren9.co ••• to •• • PHONE: 951 215-6354 protection.Give your roof a HUG when you •a rafter,you D -on. Place another screw to the left or right.If If more than 13 screws miss the rafter, CONTRACTOR INFO Only 2 •and flinal screw, securesix screws •- Multi-Tiered Waterproofing . fr HU&utilizes amulti-tiered stack of --" components to provide revolutionary Trusted Strength & Less Hassle [2SYS waferproofIng protection.The Halo cast- U aluminum,raised-perimeter foundation ounds the UltraGrip base—a foam Structural capacities of HUG were reviewed in ELEMENT ENERGY LLC. 7470 SOUND AVENUE,MATTITUCK, ed"mastic seal combination that many load directions,with racking rail running NEWYORK,11952 events water intrusion by adhering PH:(631)779 7993 snits w with the shingleadhering surface. cross-slope or up-slope in relation to roof pitch. services@e2sys.cem _ Licence-ME-52687 (MASTER ELECTRICIAN) Halo UltraGrip"`is part For further details,see the HUG certification Licence-HI-67461 _ : ... =of the QuickMounOl letters for attaching to rafters and decking. (SUFFOLK HOME IMPROVEMENT) cduct line. . = IronRidge designed the HUG, in combination NICHOLAS SOURBIS UltraGrip®Seal Technology _ --= with the RD Structural Screw to streamline 200 GREEN HILL LN, -__ - - HUG UnraGriputilitzesastate-of-trte __ _ - installs,which means the following: GREENPORT,NY 11944 art seal design that uses a unique, foam-and-masticcombination.The AHJ TOWN OFSOUTHOLD foam-backed adhesive provides an ! NO prying Shingles entirely new flashing system that-. No roof nail interference UTILITY LONG ISLAND POWER AUTHORITY conforms and adheres to every 25-Year warranty (LIPA) _ _ No pilot holes necessary and cranny of composition shingles, - Product guaranteed free PV SUMMARY filling gaps and shingle step-downs of impairing defects. No sealant(in most cases) SYSTEM SIZE (up to 1/8"in height). • No butyl shims needed (KWDC) STC 425 X 18 = .650 PTC 398.1 X 18 = .166 SYSTEM SIZE(KWAC) 5.76 @240 '.; Attachment Structural Wate�r Seal U'L (I INKO SOLAR MODULES 18 J 11KM425N-54HL4-B Loading :Design • MICROINVERTER 18 ENPHASE i 148MC-72-M-US Rafter&Deck Mounting Options The rafter-mounted Parts are designed HUG passed both Systems conform to Mount HUGS to the roof rafters,the roof HUG has been and certified for the UL 441 Section UL 2703 mechanical • deck,or both with our custom-engineered RD(rafter-or-deck)Structural Screw.The RD Triple Rated&Certified tested and rated to compliance with 27"Rain Test"and and bonding Rev Description Date . P r Structural Screw anchors HUG to the roof support 1004(Ibs)of the International TAS 100(A)-95 requirements.See 0 INITIAL DESIGN 9/26/2024 to Respect the Roof with an EPDM sealing washer,completing uplift and 368(Ibs) Building Code& "Wind Driven Rain Flush Mount Manual A UL 2703,441(27) the stack of waterproofing barriers.See p g intertek_ TAS 100(A)-95 backside for more installation information. of lateral load. ASCE/SEI-7. Test"by Intertek. for more info. e PROJECT# NA @ DATE DRAWN 912612024 DRAWN BY E.R o 2023 lronRidge,Inc.All rights reserve ents.com - SHEET# PV-7.4 TITLE ATTACHMENT SPEC THESE DRAWINGS ARE SUBJECT TO COPYRIGHT PROTECTION BY US LAW.REPRODUCTION IN ANY FORM IS EXPRESSLY FORBIDDEN WITHOUT PRIOR WRITTEN APPROVAL FROM CURRENT RENEWABLES ENGINEERING INC. Current erne� abler 28357 Industrial Blvd. 28357 Industrial Blvd. 28357 Industrial Blvd. _ ZAkIRONRIDGE IHaywddotim 5 ZALIRONRIDGE Ilronpidge.corn H ,CA 5 ��rIRONRIDGE H �OA94545 Engineering 1-800-227-9523 1.MO-227-9523 1-800-227-9523IronRidge.com IlionRidge.corn CURRENT RENEWABLES ENGINEERING INC. 3600 Lime Street,Bldg 2 Riverside,CA 92501 soLar Attn:Corey Geiger,COO,IronRidge Inc. 10.Systems using Aire Lock Stealth module clamps shall be installed with the following guidance: Entail: its:w @aeng.cD The parameters and adjustments allowed in the span tables are defined as the following: 1Ne6site:www.creng.co Date:July 15°i,2022 a) Aire Lack Stealth will function within a nodule's design load ratings.Be sure the specific module being PHONE: 951 215-6354 Re:Structural Certification and Span Tables for IronRidge Aire Rail System 1. The Aire Rail System is designed as a Risk Category 11 structure meets cture as defined by ASCE 7-10 Chart 1.5-1. used with Aire Lk Stealth ts the dimensional requirements shown in the figure below and that CONTRACTOR I N FO 2. The wind speed selection shall conform to ASCE 7-10 Fig.26.5.1A(Risk Category II wind)and any state&local the module selected is suitable for the environmental conditions of a particular project This letter addresses the structural performance and code compliance of ImnRidge's Aire Rail System.The contents of oDunl r/city amendments to the IBC.No special wind topographic features are included in the span tables and the the letter shall be read in is entirety before applying to any project design.The Aire Rail System is a proprietary rooftop topographic coefficient(Kzt)is taken as 1.0. mounting system used to support photovoltaic(PV)modules installed in portrait or landscape orientation and set parallel to the underlying roof surface.PV modules are supported by extruded aluminum Aire Rails and are secured to the rails 3. The snow load used in the span tables is the ground snow and shall conform to ASCE 7-10 Fig.7-1 and Module Glass/Cells with IronlRidge mounting damps.The Aire Rails are mounted to a roof attachment using the Aire Dock and 3/8"hardware applicable state&local county/city amendments to the IBC.If the local jurisdiction specified snow load is in the and the attachment is secured directly to the underlying roof structure.Assembly details of a typical Aire Rail System format of a flat roof snow load,it shall fast be converted to a ground snow following the local building I"!�` C 2 SYS� installation and its core components are sham in Exhibit EX-OD21. code/amendment before the application of the attached span tables.No special snow conditions are considered including unbalanced,drifting,sliding,retention,or ponding snow.The span tables do not include buildings which j i i I t ELEMENT ENERGY LLC. are intentionally kept below freezing,kept just above freezing,Or unheated. __ 7470 SOUND AVENUE,MATTRUCK, The IronRidge Aire Rol System is designed and certified tostructuralthestructural requirements of the reference standards listed i ) —_ below,for the load conditions and configurations tabulated in the attached span tables. !.j Frame CompatibiltTy:_ NEW YO RK,11952 4. The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being: I PH:(631)779 7993 ! X=11-5immservices@e2sys.com . ASCEISEI 7-10 Minimum Design Loads for Buildings and Other Structures(ASCE 7-10) I 1 Y=845mm Licence-ME-52689 a) For ground snow no greater than 42psf.S.s 2.Og for Site Class A,B,C,or D. I i . 2015 International Building Code(IBC-2D15) l (MASTER ELECTRICIAN) . 2017 NYS Uniform Code Supplement b) For ground snow greater than 65psf S,51.Og for Site Class A,B,C,or D. ) j y_,..r Licence-HI-67461 2015 Aluminum Design Manual(ADM-2015) c) For ground snow between 42 and 65psf.S,s 1.5g for Site Class A,B,C,or D. )f (SUFFOLK HOME IMPROVEMENT) 5. Roof zone size and definition conforms to ASCE 7-10 Figures 30.4-28;and 30.4-2C. The tables included in this letter provide the maximum allowable spans of the Aire Rail System for the respective loads Figure f:Aire Lock Stealth Module Frame Dimensional Requirements and configurations listed.covering wind exposure categories B,C,&D.roof zones 1.2,&3,and roof slopes of 8°to 45 6. The maximum rail cantilever length,measured from the rail end to the nearest attachment point,shall be the N I C H O LAS SO U RB I S The tabulated spans are applicable when the following conditions are met lesser of the following two conditions:113 of the allowable span provided for the respective load&configuration 200 GREEN HILL LN, condition from the span tables,or 36°. The span tables provided in this letter are certified based on the structilrel performance of IronRidge Aire Rails only with G R EEN PORT,NY 11944 1. Span is the distance between two adjacent roof attachment points(measured at the center of the attachment 7. An array to roof clearance of Y minimum must be provided. no consideration of the structural adequacy of the chosen roof attachments,PV modules,or the underlying roof fastener) supporting members.It is the responsibility of the installer or system designer to verify the structural capacity and AHJ TOWN OF SOUTHOLD B. Aire Tie rail splice can be installed at any location within a span.No splices are allowed in the rail cantilever. adequacy of the aforementioned system components in regards to the applied or resultant loads of any chosen array 2. Each module shall be supported by 2 rails(2 rail system)or 3 rails(3 rail system).Spans are calculated based on configuration.This letter certifies the IronRidge products referenced within this document and provides no determination LONG ISLAND POWER AUTHORITY 2 rail systems and are conservatively deemed acceptable for 3 rail systems. 9. Shaded cells of the span tables indicate conditions in which Aire Lock Mid Clamp connection capacity is of the project specific conditions including site loads,building profile,&roof zones,which remain the responsibility of the UTILITY (LIPA) exceeded.If such conditions are encountered contact techsupport(&.ironridge.com. installer or system designer. I PV SUMMARY 3. The underlying roof slope,measured between roof surface and horizontal plane,is 80 to 451. SYSTEM SIZE STC 425 X 18 = .650 4. The mean roof height,defined as the average of the root save height and the roof ridge height measured from OF NE Y �i (KWDC) grade,does not exceed30feet O pNG X(/ o + Digitally signed Sincerely, p qy 9 PTC 398.1 X 18 = .166 - - I,, SYSTEM SIZE b 5.76 @240 5. Module length and area shall not exceed the maximum values listed on the respective span tables. ¢ IN KO, y Gang XUa n (KWAC) m w ----- --- �}p•,2022'07 '�(� MODULES Is II M425N-554HL4-B 6. All Aire Rail components shall be installed in a professional workmanlike manner per IronRidge's Aire Rail n Installation Manual and other applicable standards for general root construction. NFO as6579 r��'O j/,•r 08:2(�.(J� _07rOOr MICROINVERTER 18 IQ8MHASE M-US Q9OFES510NP Gang Xuan,PE Senior Structural Engineer 0 2022 1ronRidge,Inc. NY Aire Rag System Certification Letter-1 0 2022 InxiRidge,fine. NY Are Rail System Ceni6cation Letter-2 02022 lmnRldge,Inc. NY Aire Red System Certifiealim Letter-3 Rev Description Date 0 INITIAL DESIGN 9/26/2024 A B PROJECT# NA DATE DRAWN gf26/2024 DRAWN BY E.R SHEET# PV-7.5 TITLE CERTIFICATION Page 1 of 1 MAR 1 8 2025 w` Southold town Current 12/23/2024 sP4k Ja bles Engineering Subject: Structural Observation Report Job: Sourbis, Nicholas - 200 Green Hill Lane A I 1 V� Project Address: 200 Green Hill Lane, Greenport, NY, 11944 �DDJb Attn.: To Whom It May Concern After inspecting the installation of the above referenced project, it is the opinion of Current Renewables Engineering to certify that to the best of our knowledge, belief, and professional judgment the PV installation is in conformance with the Structural Calculations. Verification of all relevant installation methods and materials was provided by Element Energy LLC. This letter does not waive the installer of any responsibility for improper installation. If you have any further questions on the above, please do not hesitate to reach out. .��,OF NEwy PsH ZAN0 Current Renewables Engineering Inc. Professional Engineer w info@currentrenewableseng.com �? AR FE. IONP . Exp.01/31/2028 Signed on:1 212 3/2 0 24 1760 Chicago Ave Ste J13, Riverside,CA 92507 (951)405-1733 info@currentrenewableseng.com