Loading...
HomeMy WebLinkAbout53150-Z TOWN of SOUTHOLD BUILDING DEPARTMENT SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT CAN THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 53150 Date: 07/27/2026 Permission is hereby granted to: Vincent M Claps 450 Snug Harbor Rd Greenport, NY 11944 To: Install roof mounted solar panels to an existing single-family dwelling as applied for per manufacturers specifications.Additional certification maybe required. Premises Located at: 450 Snug Harbor Rd, Greenport, NY 11944 SCTM#3S.-S-33 Pursuant to application dated 07/08/2026 and approved by the Building Inspector. To expire on 07/26/2028. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 CO-RESIDENTIAL $100.00 Total $200.00 Building Inspector m TOWN OF StyUTI-IO►LD--BUILDING DEPARTMENT f '`own Hall annex 54375 Main load P. 0. Box 1 179 Southold, NY 1 1971-0959 n R Telephone (631) 765-1802 Fax (631) 765-9502 ht tps.�� . Date Received APPLICATION FOR BUILDING PERMIT E C E For office use only PERMIT NO. U Building Inspector: , J U L - 8 2026 Applications and forms mush:be filled out to their entirety.Incomplete applications Will not be aCCe�Jted. Where the Applicant IS not the owner,an Building Department Town of Southold Owner's Authorization farm(Page 2)shall be completed. Dates OWNER(S)OF PROPERTY; Name: SCTM#1000- Project Address ,5 � � �(� Phone#: ,, Email. ^ E&O / 1 Mailing Address: � CONTACT PERSON: Mailing Address: Ct VA"�' JJ) a' ` Phone# - Email: -- 0 ' n DESIGN PROFESSIONAL.INFORMATION: Name: Mailing Address: o Phone# Email CONTRACTOR INFORMATION: Name: ,..- 0 e-M /`` i.0-1 ne Mailing Address: � 1000A f .............................. ------------ Phone#. -7-2 , Email: �� r DESCRIPTION OF PROPOSE-D CONSTRUCTION []New Structure DAddition ElAlteration ORepair ❑Demolition Estimated'Cost of Project: >�60ther $ Will the lot be re-graded? ❑Yes o Will excess fill be removed from premises? ❑Yes o 1 dui�c PROPERTY INFORMATION Existing use of property: Intended use of property: Zane or use district in which reinises is situated Are there any covenants and restrictions with respect to this property? Yes F]No IF YES, PROVIDE A COPY. ec,k ftx After Read"i . he ow�nrer"coat actor'deli ppr�ofes ionaf is responsible for all drainage and storm water issue a provided by CO. pier 236 of the Town Codex APPLICAT(ON IS,HERESY MADE to l a uiidin 4 epartmen,f fdr theftsuance of a S lidipg Permit pursuant to the,SuildingZzone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in buildings)for necessary inspections.False statements made herein are punishable as a Class A►misdemeanor pursuant to Section 210.45 of the New York State Penal Caw. Application Submitted By(print rtaL 1'�1'" .1 /' 1 uthorixed Agent Elowner Signature of Applicant: V14,111 Date: STATE OF NEW YORK) COUNTY 10K � being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract)abode named, }{ + ' i She �s the.,, (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of 26>e V Notary P�jC AUTHORIZATIONPROPERTY OWNER (Where the applicant is not the owner) 0 Ai residing at � � do hereby authorize LO,07LIJo apply on my behal''o t1h.e Town of Southold Building Department for approval as described herein. Own r s Signature Date DEBRA A SEPULVEDA Print Owner's Name NOTARY PUBLIC,STATE of NEW YORK, Registration No.0I SE6012697 2 Qualified in Suffolk Cot in?, �, m.�_�W v 4 ISLING CSULTING 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Heath J. Harpster, PE, P.Eng office(201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com July 2,2026 Element Energy LLC 7470 Sound Avenue, Mattituck, NY, 11952 Re: Engineering Services Claps Residence 450 Snug Harbor Road, Greenport, NY 11.440 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: 2x8 dimensional lumber at 16"on center. Roof Material: Composite Asphalt Shingles Roof Slope: 12 &38 degrees Attic Access: Accessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing =7 psf o New Solar Panels and Racking= 3 psf o TOTAL= 10 PSF • Live Load =20 psf(reducible)—0 psf at locations of solar panels • Ground Snow Load =46 psf o Wind Load based on ASCE 7-22 o Ultimate Wind Speed= 125 mph (based on Risk Category 11) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2025 NYS Residential Code (2024 IRC). This analysis indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent IronRidge installation manual. If during solar panel installation,the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a#14 lag screw is 194 Ibs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on two screws with a minimum penetration depth of 2",the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using two#14 lag screws with a minimum of 2" embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of rafters, and condition of the roof, the panel supports shall be placed no greater than 48"on center. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2025 NYS Residential Code (2024 IRC), current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. A_r yours, LO Scott E.Wyssli PE NY PE License No. Ca NY COA#0022571 ltC r Y+�af 0,C VVY'e sling Consultinji PLLC 76 N. M@eadouwlarook Driver Alpine UT New York COA.#0022571 Signed 7/02/2026 Expires 7/31/2027 It is a violation ofthe law forany person,unless acting uraderthe direction of a licensed professional,to alter an item in any way.if an item bearingt he-seat.of a licensed,professional is altered,the alteHng.licensed professions I shalt affix to tie!rkein their seal and the notation "attered biy"foltowed b9theirsign6ture and the date of such alteration,and a specific description of the alteration. SLING i i CONSULTING 'bP--li CONTRACTOR VI NCENT CLAPS ELEMENT d a M ENERGY SOLAR I BATTERY BACKUP 1631.779.79931 EZSYS.COM AHJ UTILITY SCOPE OF WORK VICINITY MAP ELEMENT ENERGY LLC TOWN OF SOUTHOLD PSEG LONG ISLAND (N) 11.440KW DC/8.320KW AC ROOF MOUNTED PV SYSTEM 7470 SOUND AVE, r i MATTITUCK, NY 11952, USA (26)JA SOLAR JAM54D41-440/LR MODULES (440W) I ; ;_F r , ;,� +1 631 760 7262 (26) ENPHASE IQ8MC-72-M-US (240V) MICROINVERTERS LIC TYPE: HOME (01) ENPHASE IQ COMBINER 5/5C PANEL f �t CODES AND STANDARDS WITH AMENDMENTS ;' i �m; j IMPROVEMENT,MASTER 2025 NYSBC �` �f 1 ELECTRICIAN c. i �,�% 2025 NYSFC LIC NO.: 67461-HI, 52689-ME t 2025 NYSECC 1 l; r . ' �� 2023 NEC —` 1 ``' PROJECT INFO&ADDRESS 450 Sriug'Harbor�(r r F,r�r Rd,Greeniiort,NXr _ VINCENT CLAPS 11944,-United States 450 SNUG HARBOR RD, ENVIRONMENTAL _ \,, GREENPORT, I t \ NY 11944, USA WIND SPEED: 125 MPH SNOW LOAD: 46 PSF EXPOSURE CATEGORY: C -" SYSTEM SIZE DC SIZE: 11.440 KW DC-(STC) AC SIZE: 8.320 KW AC GENERAL NOTES PROJECT NOTES: SHEET INDEX THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE PV-1 COVER SHEET NATIONAL ELECTRIC CODE (NEC)ARTICLE 690,ALL PV-2 SITE PLAN-1 MANUFACTURER'S LISTING AND INSTALLATION INSTRUCTIONS, PV-2.1 SITE PLAN-2 AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY PV-3 ATTACHMENT PLAN HAVING JURISDICTION'S (AHJ)APPLICABLE CODES. PV-3.1 STRUCTURAL PLAN -THE UTILITY INTERCONNECTION APPLICATION MUST BE PV-4 ELECTRICAL , APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL PV-4.1 ELECTRICAL CALCULATIONS OPERATION PV-5 LABELS -GROUND FAULT DETECTION AND INTERRUPTION (GFDI) PV-6 RESOURCE DOCUMENT DEVICE IS INTEGRATED WITH THE MICRO INVERTERS IN PV-6.1 RESOURCE DOCUMENT ACCORDANCE WITH NEC 690.41(B) PV-6.2 RESOURCE DOCUMENT °°' fir, 4 \1 ALL PV SYSTEM COMPONENTS; MODULES, PV-6.3 RESOURCE DOCUMENT `' UTILITY-INTERACTIVE INVERTERS,AND SOURCE CIRCUIT PV-6.4 RESOURCE DOCUMENT yssling onsulfi lg, PILLC COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN PV-6.5 RESOURCE DOCUMENT 76 Meadowbrook Drive,.Alpine UT PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4: PV PV-6.6 RESOURCE DOCUMENT New York COA;9.0022571 MODULES: UL1703, IEC61730, AND IEC61215,AND NFPA 70 PV-6.7 RESOURCE DOCUMENT CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, PV-6.8 RESOURCE DOCUMENT Signed 7/02/2026 519 COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY Expires 7/31/2027 - MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX It cling-ndernofthelawforanype�son,unless DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7. acringunderfhedirectiot m i licensed ALL INVERTERS, PHOTOVOLTAIC MODULES,PHOTOVOLTAIC professional,toalteran item in anyway.tfan PANELS,AND SOURCE CIRCUIT COMBINERS INTENDED FOR item tiearingtheseat.of:alicenseclprofessional USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED isattered,,the altering iicensed professional shalt DRAWN BY GS AND LISTED..FOR THE APPLICATION PER690.4. SHALL BE affixtotlieiritemtheirseal and the ngtatian DATE 7/2/2026 INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING "altbredby"followed bytheirsignature and the OR LABELING [NEC 110.3]. date ofsuch alteration,and a specific REVISION -ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL detcription ofthe alteration. SIGNATURE BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT.ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS PV-1 REQUIRED BY THE NEC AND AHJ. COVER SHEET CONTRACTOR SCOPE OF WORK TOTAL ROOF SQUARE FOOTAGE IS: 3245.25 FTZ (N) 11.440KW DC/8.320KW AC ROOF MOUNTED PV SYSTEM NEW ARRAY SQUARE FOOTAGE IS: 559.19 FTz ® ELEMENT (26)JA SOLAR JAM54D41-440/LR MODULES (440W) COVERED BY NEW SOLAR IS: 17.23% ENERGY (26) ENPHASE IQ8MC-72-M-US(240V) MICROINVERTERS SOIARI BATTERY BACKUP1631.779.7993JUSYS.COM (01) ENPHASE IQ COMBINER 5/5C PANEL 0) ELEMENT ENERGY LLC (E)GATE 7470 SOUND AVE, MATTITUCK, NY 11952, USA _ 1291_11„ +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER _ ELECTRICIAN LIC NO.: 67461-HI, 52689-ME s PROJECT INFO&ADDRESS w� VINCENT CLAPS 450 SNUG HARBOR RD, ° GREENPORT, /46,3„ NY 11944, USA 0 ® SYSTEM SIZE DC SIZE: 11.440 KW DC-(STC) ;V AC SIZE: 8.320 KW AC Q) O / ® / a (3F rot- $, / -6I, O Q nw "'rrti h ry u O yssliing Cansvlfing, PLaLC 76 Id. Meadow+bPook Dnive,Alpine UT New York COA#0022571 — e Signed 7/02/2026 Expires 7/31/2027 LEGEND ®FIRE PATHWAYS PROPERTY LINE — — —/ 130►_1 r. -0 FENCE DRAWN BY GS ® SKYLIGHT/CHIMNEY (E) FENCE Itisa violation of the law for any person,unless aeting:under the direction of;a licensed DATE 7/2/2026 O ❑ VENT/OBSTRUCTION professional,to alte'r,an item in any inlay.ff.an REVISION (E) MAIN HOUSE item beari ng'the sea l of a licensed professional is altered,the altering licensed professional shall SIGNATURE SITE P LA N A affix'to their item theirseal and fhe notation "Altered by followed by their'signature and the PV-2 �� _ n date of such:alteration,and a'specific SCALE:1/16 = 1 -0 SITE PLANA description ofithe•atteration. CONTRACTOR SCOPE OF WORK (N) 11.440KW DC/8.320KW AC ROOF MOUNTED PV SYSTEM (N)ENPHASE IQ COMBINER 5/5C WITH ® ELEMENT ENPHASE IQ GATEWAY (26)JA SOLAR JAM54D41-440/LR MODULES (440W) (OUTSIDE HOUSE) go ' '�. ENERGY (26) ENPHASE IQ8MC-72-M-US (240V) MICROINVERTERS SOLARI BATTERY BACKUP 1631.779,79931Ems.COM (01) ENPHASE IQ COMBINER 5/5C PANEL (N)VISIBLE LOCKABLE LABELED AND FUSED AC DISCONNECT ELEMENT ENERGY LLC _O (PV DISCONNECT) (OUTSIDE HOUSE) 7470 SOUND AVE, LADDER ACCESS M (E)UTILITY METER MATTITUCK, NY 11952, USA S +1 631 760 7262 (OVERHEAD SERVICE)(OUTSIDE HOUSE) LIC TYPE: HOME ao oov wn IMPROVEMENT, MASTER dsw ELECTRICIAN LIC NO.: 67461-HI, 52689-ME (E)MAIN SERVICE PANEL (INSIDE BASEMENT) PROJECT INFO&ADDRESS O VINCENT CLAPS M 450 SNUG HARBOR RD, GREENPORT, ° ® NY 11944, USA SYSTEM SIZE DC SIZE: 11.440 KW DC-(STC) C3 AC SIZE: 8.320 KW AC (N)(26)JA SOLAR JAM54D41-440/LR MODULES WITH ENPHASE IQ8MC-72-M-US(240V) MICROINVERTERS UNDER EACH MODULE(240V) 0 1Ivk _ ' 0 a n � 4 t L r ° yssling Consuffing,PLLC It is a.v6otation of the law for any person,unless .76 F'.Meadowbroo:k DFive,Alpine UT O acting u> o1er the direction of a licensed Now York COA#0022371 professional,to alter an item in any tinny.flan M item.bearingthe-seeilofa'licensedprofessional Signed 7/02/2026 LEGEND Expires 7/31/2027 is altered,the altering licensed professional shall O 3-Orr Or affix to their item their seal.and the notation ®FIRE PATHWAYS M CV) "altered by"fpllowed 4ytheir signature and the PROPERTY LINE date of such'atteration,and aspec'rfic S description of the alteration. .FENCE LADDER ACCESS DRAWN BY GS ® SKYLIGHT/CHIMNEY O ❑ VENT/OBSTRUCTION DATE 7/2/2026 REVISION SIGNATURE SITE PLAN-2 TOTAL ROOF SQUARE FOOTAGE IS: 3245.25 FTz PV-2.1 SCALE:3/32" = V-0" NEW ARRAY SQUARE FOOTAGE IS: 559.19 FTz COVERED BY NEW SOLAR IS: 17.23% SITE PLAN-2 CONTRACTOR DEAD LOAD CALCULATION LEMENT BOM QUANTITY LBS/UNIT TOTAL MON EN RGY WEIGHT(LBS) 3-3 31-1 SOLARiBATTERY BACKUP i631.7T9.7993iE25Y5.COM JA SOLAR JAM54D41-440/LR 26 46.7 1214.20 40'-5" MODULES ELEMENT ENERGY LLC MID-CLAMP 38 0.15 5.70 7470 SOUND AVE, END-CLAMP 28 0.15 4.20 — MATTITUCK, NY 11952, USA I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I RAIL LENGTH 24 6.36 152.64 = 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I I I I I I I I I I I I I +1 631 760 7262 I I I I I I I I I I I I I I I I I I I SPLICE BAR 10 0.525 5.25 I I I I I I I I I I I I I I F II I1 II II I 1 1 1 1 1 1 1 1 1 1 1 1 LIC TYPE: HOME IRONRIDGE HALO ULTRA 90 0.57 51.30 IMPROVEMENT, M ASTER ELECTRICIAN GRIP I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I LIC NO.: 67461-HI,52689-ME ENPHASE IQ8MC-72-M-US 26 2.43 63.18 1 1 I I I I I I I I I I I I I I I I 1 1 I I I 1 I I I I I (240V) MICROINVERTER _ 1 1 TF 1 1 1 TOTAL WEIGHT OF THE SYSTEM (LBS) 1496.47 `_� i i I I I I I I I I I d i i i 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 i i PROJECT INFO&ADDRESS I I I I I I I I I I I I I I I I I I I I I I I I I VINCENT CLAPS TOTAL ARRAY AREA ON THE ROOF (SQ.FT) 559.19 i i I IT I I 1 I 1 T I I I I T 111 I 1 1 1 I I I 450 SNUG HARBOR RD, WEIGHT PER SQ.FT. (LBS) 2.17 I I 1 1 1 1 I I I I I I 1 1 1 I I 1 1 1 1 1 I I I I 1 I I I I I I I I I I I I I I I I I 1 I I I I I I I I I I I GREENPORT, WEIGHT PER PENETRATION (LBS) 16.63 I 1 I 1 NY 11944, USA 4'-0" ARRAY 1 SYSTEM SIZE DC SIZE: 11.440 KW DC-(STC) TILT- 12 DEG AC SIZE: 8.320 KW AC AZIMUTH - 282 DEG 0 -CLAMP • - IRONRIDGE HALO ULTRA GRIP - IRONRIDGE AIRE Al 54'-10" 11'-6" 4'-8" A � -------- -RAFTER C. 1 i i i i i i i i i o pAll ; )L3 90 -TOTAL MOUNT 1 I 1 I I I I ❑I I I I I I 1 I I I � �� � .:�,��(;;' r 1 I I I IT I TI I I I I I ( s=p I LL I I I I I I I I I I t =r 23 �{e I I I I I I I ,� I I I I I I I I I I 1 I I I I I I -, -y,' ROOF SECTION(S) i i i i i i I T I T I I sslcng Consulting;PLLC I I I I I 76 N - eadow wrack Driers Ai ine UT It i s a wi olation of the law for anype rson,unless I I I I I I P ROOF MATERIAL- I I 1 acting underthedirection of a licensed 1 1 1 ew,r York CO,Q14'.0022571 I I I I I I I I I I I I I I I I I COMPOSITE SHINGLE 1 1 1 professional,to alter an item in anyway.If an I I I I I I I I I I I I I I Signed 7/02/2026 ROOF 1 RAFTER SIZE-2"X8" i i i item bearingthe seal of.aAicensed professional Expires 7/31/2027 O.C. SPACING- 16" I i I is altered,the altering licensed professional shall MODULES-20 i afFxto their item their.seal and the notation ARRAY 2 ROOF MATERIAL- "altered0y"foUowedbytheir'signatureandthe TILT- 38 DEG COMPOSITE SHINGLE date of such alteration,and a specific ROOF 2 RAFTER SIZE-2"X8" descriptionAZIMUTH - 282 DEG O.C. SPACING-16" o fthealteration. DRAWN BY GS MODULES-06 DATE 7/2/2026 REVISION SIG!�ATURE 1 ATTACHMENT PLAN PV-3 SCALE:1/8"=V-0" ATTACHMENT PLAN CONTRACTOR ELEMENT IM EI ® EN RGY SOLAR I BATTERY BACKUP 1631.779.7993 J USYS.COM ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER MODULE BOTTOM MOUNTING CLIP ELECTRICIAN CLAMP w 4" BOLT LIC NO.: 67461-1-1I, 52689-ME AND LOCK WASHER PROJECT INFO a�ADDRESS VINCENT CLAPS 450 SNUG HARBOR RD, JA SOLAR JAM54D41-440/LR GREENPORT,NY 11944, USA i SYSTEM SIZE IRONRIDGE HIRE Al j DC SIZE: 11.440 KW DC-(STC) � AC SIZE: 8.320 KW AC s" BOLT (E) COMPOSITE SHINGLE IRONRIDGE QUICKMOUNT HUG (2) - 1/4" x 3" STAINLESS STEEL SCREWS , WITH MINIMUM 2" EMBEDMENT an N, (E) RAFTER 211X8" @ 16" O.C. yssfing ltoItiStllfilng,PLLtv 2 76IN Meadowbrook Drive;A'Ipirte UT Now York COA#0022571 It is a violation of the law for any person,unless 26 actingunderthedirectionof:alicensed Signed7 professional,to:alter an iterri in any Way.Ilf;an EXplres 7/31 31/2/2027 item bearing the seal of a licensed professional is aftered,the altering.licensed professional shall affix.to their item..theirseal arid tttenotation DRAWN BY GS "altered try"followed by their signature and the DATE 7/2/2026 date of such alteration,and a specific description of the a lte ration. REVISION SIGNATURE STRUCTURAL PLAN PV-3.1 SCALE:NTS STRUCTURAL PLAN CONTRACTOR SOLAR MODULE SPECIFICATIONS INVERTER SPECIFICATIONS NOTE: MANUFACTURER/MODEL# JA SOLAR JAM54D41-440/LR MANUFACTURER/MODEL ENPHASE IQ8MC-72-M-US(240V) - ALL CONDUCTORS ARE COPPER UNLESS OTHERWISE ' M ELEMENT MODULES # MICROINVERTER �, NOTED. ENERGY VMP 32.47V MIN/MAX DC VOLT RATING 22V MIN/58V MAX 50LARI BATTERY 13ACKUP1631.779.79931 E25Y5.COM IMP 13.55A MAX INPUT POWER 460W VOC 38.90V NOMINAL AC VOLTAGE RATING 240W 211-264V ELEMENT ENERGY LLC ISC 14.31A MAX AC CURRENT 1.33A 7470 SOUND AVE, TEMP.COEFF.VOC -0.25%/°C MAX MODULES PER STRING 12(SINGLE PHASE) MATTITUCK, NY 11952, USA +1 631 760 7262 MODULE DIMENSION 69.37"L x 44.65"W x 1.18"D(In Inch) IMAX OUTPUT POWER 320 VA LIC TYPE: HOME TO UTILITY GRID IMPROVEMENT, MASTER (N) (26)JA SOLAR JAM54D41-440/LR (3)AWG#12,SKU: Q-12-RAW-300, -1 L2 N ELECTRICIAN MODULES THHN LINE (E) BI-DIRECTIONAL UTILITY LIC NO.: 67461-HI, 52689-ME (N)(1) PV AC LOAD CENTER, METER 1-PHASE, 3-W, _� (N) (1)AC DISCONNECT: M 120V/240V,200A RATED PROJECT INFO&ADDRESS 11 MICROINVERTERS IN BRANCH CIRCUIT 1 (1) 15A/240VAC&(3)20A/ VISIBLE, LOCKABLE, LABELED IQ GATEWAY 240VAC CIRCUIT BREAKERS, (OVERHEAD SERVICE) VINCENT CLAPS 60A FUSED, (2)50A FUSES, LOAD o o a NEMA 3R, UL LISTED,125A RATED (OUTSIDE HOUSE) 240V NEMA 3R, UL LISTED 460 SNUG HARBOR RD, (OUTSIDE HOUSE) (UTILITY DISCONNECT) GREENPORT, (OUTSIDE HOUSE) NY 11944, USA L1 L1 SUPPLY SIDE TAP L2 L2 II 15A/2P N SYSTEM SIZE G —— G __ (E)MAIN BREAKER DC SIZE: 11.440 KW DC-(STC) 09 MICROINVERTERS IN BRANCH CIRCUIT 2 — — LINE 240 V,200A/2P AC SIZE: 8.320 KW AC 20A/2P (TOP FED) ol^ (E) MAIN SERVICE o S PANEL 200A RATED, — 1 240V ^, ^, �. J 20A/2P I I o (INSIDE BASEMENT) —— ———— LOAD LINE SIDE INTERCONNECTION ELECTRICAL ONLY N AT MAIN PANEL 06 MICROINVERTERS IN BRANCH CIRCUIT 3 20A/2P I O PER ART. 705.11 OF Nl ly (70 PER MANUFACTURER GEc SPECIFICATIONS, EITHER _I_ EXISTING GROUNDING b 10A OR 15A BREAKER IS — ELECTRODE SYSTEM TO J ——————— SUITABLE FOR USE It is aviolation.ofthe law for any person„unless EARTH �y REF. NEC 250.52,250.53 A F ( ) o os9403 acting underthe direction of licensed ,o (N)(26) ENPHASE IQ8MC-72-M-US G professionat,to.alteran item in any Way If an gOFESSIO�� (240V) MICROINVERTERS ONE L—— ——J item:bearingthesealofaticensedprafessional sling Consulting,PLLC UNDER EACH MODULE 'is altered,the altering licensed professional shatL 76 i.Meadowbrook Drive,Kpine UT affix'to their item their.seal and the notation' New York can#12 026 Signed 7/02/2026 "altered by'followed by their signature and the Expires 7l31/2028 date of such alteration,.and a specific desc ripti on of the a Iteration_ PHASE CONDUCTOR QTY, SIZE AND TYPE GROUND CONDUCTOR QTY, SIZE CONDUIT CONDUIT ID PER CONDUIT NEUTRAL QTY, SIZE AND TYPE PER CONDUIT AND TYPE PER CONDUIT SIZE TYPE DRAWN BY GS 1 3 AWG#12 Q-12-RAW-300, THHN NA NA NA 1 AWG#8 BARE,COPPER EGC 3/4" PVC DATE 7/2/2026 2 2 AWG#8 THHW-2,COPPER 1 AWG#8 THHW-2,COPPER 1 AWG#8 THHW-2,COPPER EGC 3/4" PVC REVISION SIGNF1,TURE 3 2 AWG#6 THHW-2,COPPER 1 AWG#6 THHW-2,COPPER 1 AWG#6 THHW-2,COPPER EGC 1" PVC PV-4 ELECTRICAL CONTRACTOR ELEMENT 1 ® EN RGY AMBIENT TEMPERATURE SPECS NUMBER OF CURRENT SOLAR I BATTERY BAOKUPI631.779.7993IE26Y5.00M PERCENT OF VALUES CARRYING CONDUCTORS IN EMT RECORD LOW TEMP -16° ELEMENT ENERGY LLC 7470 SOUND AVE, AMBIENT TEMP (HIGH TEMP 2%) 340 0.80 4-6 MATTITUCK, NY 11952, USA CONDUIT HEIGHT 7/8" 0.70 7-9 +1 631 760 7262 LIC TYPE: HOME ROOF TOP TEMP 560 0.50 10-20 IMPROVEMENT, MASTER CONDUCTOR TEMPERATURE RATE 900 ELECTRICIAN LIC NO.: 67461-1-1I, 52689-ME MODULE TEMPERATURE COEFFICIENT OF Voc -0.25%/°C PROJECT INFO&ADDRESS VINCENT CLAPS CALCULATIONS: 450 SNUG HARBOR RD, GREENPORT, NY 11944, USA 1. CURRENT CARRYING CONDUCTOR 2. PV OVER CURRENT PROTECTION ...NEC 690.9(B) SYSTEM SIZE = TOTAL INVERTER O/P CURRENT x 1.25 DC SIZE: 11.440 KW DC-(STC) (A) IN BETWEEN MICROINVERTER TO IQ COMBINER PANEL = (26 x 1.33) x 1.25 — 43.22 A AC SIZE: 8.320 KW AC AMBIENT TEMPERATURE - (34)OC ...NEC 310.15(B)(1)(1) TEMPERATURE DERATE FACTOR - 0.96 ...NEC 310.15(B)(1)(1) GROUPING FACTOR - 0.8...NEC 310.15(C)(1) CONDUCTOR AMPACITY ELECTRICAL ONLY = (INV O/P CURRENT ) x 1.25 / A.T.F / GX ...NEC 690.8(B) of NEW �P .�NOMq 9 = [(11 x 1.33) x 1.251 / [0.96 x 0.81 = 23.81A 7 " ., ; SELECTED CONDUCTOR - #12 Q-12-RAW-3009 THHN ...NEC 310.16 o It is a viotation of the law for any person,unless fiQA 09941� acting-underthe direction ofa LicensedFESStONF'�� pfofessional,taatteran item in anyway;If an (B) AFTER IQ COMBINER PANEL y�sling consulting,PLLC item bearingthe seat:of a€icenSetl professi onal 7e ,�leaaaxrllrook Drive,�q7ne�!T is a€tered,the altering.licensed professional shalt New MoTk COA X 022092 TEMPERATURE DERATE FACTOR - 0.96 Signed 7/02/2026 affix to their item#hei rseal and the notation GROUPING FACTOR - 1 ,.slteredhy"fbllowedby their signature and the Expires7/31/2028 date of such alteration,.and a specific description of the alteration_ CONDUCTOR AMPACITY = (TOTAL INV O/P CURRENT) x 1.25 / 0.96/ 1 ...NEC 690.8(B) DRAWN BY GS _ [(26 x 1.33) x 1.251 / [0.96 x 11 DATE 7/2/2026 = 45.03 A REVISION SELECTED CONDUCTOR - #8 THWN-2 ...NEC 310.16 SIGNATURE PV-4.1 ELECTRICAL CALCULATIONS CONTRACTOR ELEM' ® NT ENERGY E SOLARI BATTERY BACKUP 1631.779.79931E25YB.COM Solar Module Solar Module Micro Inverters IQ COMBINER ELEMENT ENERGY LLC MAIN SERVICE 7470 SOUND AVE, PANEL AC DISCONNECT PANEL MATTITUCK, NY 11952, USA Outside Door Outside Door +1 631 760 7262 LIC TYPE: HOME OEM Cables should be marked by the manufacturer 3'4 3,6,8,9,11 3,9,10 IMPROVEMENT, MASTER Inside Door Inside Door ELECTRICIAN 5,6,7 5,6,7 It is a violation of the taw forany person,unless LIC NO.: 67461-HI, 52689-ME "Custom acting•underthedireotionofalicensed NEC 690.13(B) professional,to,atter.an ite.m,in anyway.than PROJECT INFO&ADDRESS NEC 690.54 Directory .item bearingthesealof a1€censed professional NEC 690.56(C) Placard VINCENT CLAPS NEC 705.12(B)(3) is a leered,the altering Licensed professional shall NEC 690.13(B) NEC 705.11 460 SNUG HARBOR RD, NEC0.13(B) 705 s#fix:tottteiri;emtheir,sealandtltenotatian NEC .56(B)NEC 705.12(B)(3) eirsignature and the' GREENPORT, NEC 05.10 NEC 690.56(B) "altered W-foLlowed'byth NEC 705.10 date of sueh:atteration,and:a°specific NY 11944, USA NEC 705.11 description of the-alteration. NEC 705.12(B)(3) SYSTEM SIZE DC SIZE: 11.440 KW DC-(STC) AC SIZE: 8.320 KW AC ® WARNING:PHOTOVOLTAIC CAUTION ® F POWER • - POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE ELECTRIC SHOCK HAZARD FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: IF A GROUND FAULT IS INDICATED -- --- ---- [7] - ---- NORMALLY GROUNDED CONDUCTORS ELECTR ICALIONLY MAY BE UNGROUNDED AND ENERGIZED • • • • • N COMBINER PANEL � � � (OUTSIDE HOUSE) OF NEtyy - • • • R PV DISCONNECT � -ICNaMRSF 9¢ (OUTSIDE HOUSE) I . UTILITY METER 8 CAUTION:SOLAR ELECTRIC (OVERHEAD SERVICE) �t ELECTRIC SHOCK HAZARD ❑ SYSTEM CONNECTED (OUTSIDE HOUSE) THE DC CONDUCTORS OF THIS S��A 09947'6 1G�� PHOTOVOLTAIC MAY BE SYSTEM ARE UNGROUNDED FESS10 PV ARRAY MAIN SERVICE PANEL (INSIDE BASEMENT) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN *yssling Consulting,PLLC 78rook ® eew Ynrbk COA give,U2208 Plne IU7 F91 "TURN RAPID SHUTDOWN SWITCH TO THE Signed 7/02/2026 ELECTRIC SHOCK HAZARD SHUOT DOWN IPVOSYSTEM s PV PANELS Expires 7131/2028 DO NOT TOUCH TERMINALS AND REDUCE TERMINALS ON BOTH LINE AND SHOCK HAZARD 0 LOAD SIDES MAY BE ENERGIZED IL IN THE ARRAY IN THE OPEN POSITION O m [4] WARNING HazardKOCAUTI©N; SOLAR CIRCUIT = DRAWN BY Gs C�ntact authorized service provider CD No user serviceable parts inside DATE 7/2/2026 Z) REVISION 1 1-51 WARNING:DUAL POWER SOURCE • • • SYSTEM DISCONNECT � S I G N A T U R E SECOND SOURCE IS PHOTOVOLTAIC SYSTEM F1-11 •OPERATING PV-5 LABELS CONTRACTOR ELEMENT ENERGY ty 513LAR1 BATTERY BACKLIP1631.779.79931 E25Y5.CDM 4K ELEMENT ENERGY LLC Harvest the Sunshine Y JAM54D41 7470 SOUND AVE MATTITUCK, NY 11952, USA t r-- 4 4 s f ; _ +1 631 760 7262 fr- , 455 W � ((c lil �; l ' _, ra LIC TYPE: HOME ' ' =r. IMPROVEMENT, MASTER ELECTRICIAN FFLIC NO.: 67461-1-1I, 52689-ME F: l JAM54D41 L E Black Modules 9 PROJECT INFO&ADDRESS 3 mm s e /_- , wow . - e mining no[ MECHANICAL PARAMETERS n-type Double Giass Monofaciai Modules tl gHoles) - P�' - _. apiares 1 i -eel( _ Mono HARBOR R VINCENT CLAPS Mounting hclesA Weight 22kg 30 ..... _ .. .. -. -_ ._.-.._- mmx1134mmx30mm RT Dimensions.. . . 1762 ...... ___._.___ 450 SNUG v ea able m1(1 C)12AwG(uL) GREENPO 'c Shonf2me No.otcell J _ 108(6X18), NY 119", USA i Section Size 4m Junction Box - IP68 3diodes A; 30 1 Connector Staubli PV-KST4-EV,02A/xy,PV KBT4 EV02A/xy .� 0roundm Holes h Premium Cells 4Places042 �---�J geSalarQ 4.10451/QC4_10-35 SYSTEM SIZE ---- - _.- 1134 1096 J '3D Long frame -unit: m Cattle l ength Portmd:400mm(+)/200mm(-) m DC SIZE: 11.440 KW DC-(STC) - (including Connector) Landscape:1700mm(-j/1200mm(-) __ _---._-___ _ - _ _ AC SIZE: 8.320 KW AC Front Glass/Back Glass 1.6mm/1.5mm 260/ - -- -. n- PackagmgConfigurabon 36pcs/Pallet 936pcs/40HQContainer Byeium+ o _Country ofManufacture_r ___ Chma/Viemam. 16 BB - Remark:customized frame color and cable length available upon request up To ty. MBB Half-Cell Cell Conversion - Technology Efficiency ELECTRICAL PARAMETERS AT STC CHARACTERISTICS JAM54D41 JAM54D41 JAM54D41 JAM541)41 TYPE -440/LR 445/LR -450/LR -455/LR 1°Current-Vcltage Curve JAM54D41-049/LR Premium Modules _ - -- - - - - -- ` ,p`� Rated Maximum Power(Pmaz)[W] 440 445 450 455 tz: l000wlm, Open Ci rcult Voltage(Voc)M 38.90 _ 910 _ 40.30 40.50 yo� e°°w/ Higherpower LID ntype with very Maximum Power Vo(tage(Vmp_)IV] 32.47 3265 _ 32.99 _ 33.3.3 a a I O generation better LCOE _ Lower LID 14 - - -- - -_ - Short Circuit Curren[;Isc)[A] 14.31 .40 14.41 14.42 z; zOOW;m* o Maximum POwef Cu--nt(ITI-)[A1 13.55 13.63 13.64 13 65 0 10 20 36 40` CBetter Temperature Better low irradiance _. __.. Vcltagep _ Coefficient m response Module Efficiency[%j 22.0 22.3 22.5 22.8 Power-Voltage Curve JAM54D41-z40/LR Power TOl-rave_ -S-+lOW ;oxt. aynn Mm,ntaoai mm�ia Olalacs Mndmn Temperature CoeYTcien of Isc(a_Isc) +0.045°fr!°C 1-steow+m= ��t ear Ped°rmanae ble. y a�i ss>" TemperatureC Standard NoduleLlnearP dmmanraWarmnty oeYlcieo-o(Voc(R_VocJ 0. %;250 'C _ _ Zoowlm .. _ Temperature CoeFicien o(Pmaz(y Pmp) 0.2901/o/1C F 2DO - STC Irradiance 1G00 RemaarkW/m',cell temperature 25'C,AM15G i 1 imFF ,k I Remark: 0 :Ele_[n_al data In this catalog do no[2fe otl to hule and they a-e not Dart of h n t0 zo 3r. FroneoRer. Vcltage('/) ha They only serve for comparison among different module types.lap Measurement[orletanre a±STC:pmaKi3�,Vocs346 and Iscf i4o. ELECTRICAL PARAMETERS AT NOCT And Low lrradianceOf20OW/ma OPERATING CONDITIONS 146 bt-year Ceg"J.dm 0A%Anwai oeyiacauon 0-My- - -- JAM54D41 JAM54D41 JAM54D41 JAA154D41 Maximum S -040/LR -445fLR -050/LR -455/LR ystem'✓Oltage 1$OO- DC 15 15-year p duct ro 30 0.yea•u ear power --ty O 3 outpvtwarmety TYPE - 10°io200W/m° 10%20CW/m' 10So200WW 30°m,200W/mr. 7 _ Operating Temperature' -40°C-+0'C *Remark:Tile perroimancewaaaoty applies at 5rc condition. Rated Max Power(Pmax)(%VI 333 85, 337 86 341 87 34e 68 Maximum Series Fuse Rating 25A Comprehensive Certificates Open CircuitvoltageNoc)IV] 3G.61 30.G0 37.00 3G.79 38.14 37.70 38.33 37,95 Maximum Static Load,Font 3600Pa,1.5 I EC 61215,IEC 61730 Max Power Voltage(Vmp)]V] 30,73 31.65 30.39 31.94 31.22 32.22 31.5c 2.51 Maximum Static Load,Back .. 1600Pa,1.5 ISO 9001:2015 Quality management systems Short Circuit Current(Isc)[A] 11.45 2.86 11.52 2.8E 11.53 2.63 11.54 2.88 NOCT 45t2'C ISO 140G1:2015 Environmental management systems Max Power Current(Imp)[A] 10.84 2.69 10.90 2.70 10.91 2.71 10.92 2.71 Safety Class Class II ISO 45OU:2018 occupational health and safety NOCT Irradiance 800W/m2,ambient temperature 20C.wine speed Innis,AM7.5G Fire Performance IJL Type 38/classC �+ management Systems Low Irradiance _ (200'*2)W/m',module at(25t2)'C 'PVmodule93'-.percentile operating temperature:70`C DRAWN BY GJ IFC 62941:?019 TPrrastrial phntovnitair(PV)modules-Quality system for PV module manufacturing DATE 7/2/2026 E BLUE4.0 JASOLAR Headquarters JA Solar Technology Co.,Ltd. I Specifications srbjectto technical changes and tests. REVISION No. Building,Nuode Center, Courtyard,East Auto Museum Foad, JA Solar reserves the right of final Interpretation. eTQvj C E 1 �l g Fen tai District,Bei in Te1:g86 30 6361 1888 Fax+86 10 6361 1999 Version No.:Aus-EN-2025071 1A SIGNATURE E-mail:salesCjasolaccom marketing@jasotaccom www.jasolar.com PV-6 RESOURCE DOCUMENT CONTRACTOR ELEMENT Id 0 MENERGY SOLARI BATTERY BACKUP 1631.779.79931E28Y5.COM ENPHASE. �01 IQ8MC Microinverter ELEMENT ENERGY LLC 7470 SOUND AVE, INPUT DATA CDC) UNITS ------ MATTITUCK, NY 11952, USA Commonly used module pairings W - +1 631 760 7262 wModule compatibility To meet compatibility.PV modules must be within the following max.input DC voltage and max.module Ip LIC TYPE: HOME Module compatibility can be checked at httos://enyhase.com/installers/microinvertem/calculator. MPPT voltage range v 25-45 IMPROVEMENT, MASTER ELECTRICIAN Operating range v ,B-SB LIC NO.: 67461-HI,52689-ME Min./Max.start voltage v 22/58 Max-input DC voltage V 60 PROJECT INFO&ADDRESS Max.continuous operating DC current A 14 VINCENT CLAPS Max.input DC short-circuit current A 25 - Max.module I. A 20 460 SNUG HARBOR RD, Over/oltage class DC port 11 GREEN PORT, DC port backfeed current mA 0 NY 11944, USA PV array configuration Ungrounded array;no additional DC side protection required;AC side protection requires max 20 A per branch circuit OUTPUT DATA(AC) UNITS 108MC-72-M-LIS @240 VAC 1109MC-72-M-US @20e VAC SYSTEM SIZE Peak output power VA 330 315 DC SIZE: 11.440 KW DC-(STC) Max.continuous output power VA 320 310 AC SIZE: 8.320 KW AC Nominal grid voltage(L-L) v 240.split-phase(L-L),180• 208,single-phase(L-L).120' 1 Q 8 M C Microinverter Easy to Install Min./Max.grid voltage v 211-264 183-229 -orming•,software- Lightweight and compact with plug- Max.continuous output current A 1.33 1.49 defined microinverters with split-phase power conversion capability to convert DC power to and-play connectors Nominal frequency Hz 60 AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary Power line communication(PLC) Extended frequency range H. 47-68 application-specific integrated circuit(ASIC),which enables the microinverter to operate in between components lit grid-tied or off-grid modes.This chip is built in advanced 55-nm technology with high-speed AC short circuit fault current over three digital logic and has superfast response times to changing loads and grid events,alleviating Faster installation with simple two-wire cycles A 270 constraints on battery sizing for home energy systems. cabling Max.units per 20 A(L-L)branch circuit 3 12 10 High productivity and reliability Total harmonic distortion % <5 hase Produces power even when the grid is down` Overvo@age class AC port III i I • More than one million cumulative hours AC port backfeed current mA 18 3 of testing Power factor setting 1.0 Part of the Enphase Energy System, IQ8 Series Microinverters redefine Class II double-insulated enclosure P 9Y Ys Grid-tied power factor(adjustable) 0.85 leading...0.B5lagging IQ8 Series Microinverters integrate with reliability standards with more than one Optimized for the latest high-powered the IQ Battery,IQ Gateway,and the million cumulative hours of power-on PV modules Peakefficiency % 97.4 97.2 Enphase App monitoring and analysis testing,enabling an industry-leading CEC weighted efficiency % 97.0 96.5 software. limited warranty of up to 25 years. Microgrid-forming Nighttime power consumption mw 33 25 Complies with the latest advanced grid MECHANICAL DATA UNITS 0 support Ambient temperature range -40•C to 65'C(-40'F to 149'F) NAV • Remote automatic updates for the CERTIFIED latest grid requirements Relative humidity range 4%to 100%(condensing) Configurable to support a wide range DC connector type staubli Mc4 Connect PV modules quickly and easily I08 Series Microinverters are UL Listed of grid profiles Dimensions(H-W-D);Weight 212 mm(8.3•)-175 mm(6.9')-30.2 mm 0.2');1.1 kg(2.43 lbs) to the I08 Series Microinverters that have as PV rapid shutdown equipment and Meets CA Rule 21(UL 1741-SA)and IEEE Cooling Natural convection-no fans integrated MC4 connectors. conforms with various regulations when 1547:2018(UL 1741-SB) Approved for wet locations;Pollution degree Yes;PD3 installed according to the manufacturer's Instructions. Enclosure Class II double-insulated,corrosion-resistant polymeric enclosure NOTE: • 108 Microinverters cannct be mixed together with Environ.category;UV exposure rating NEMA Typo 6;outdoor previous generations of Enphase microinverters COMPLIANCE DRAWN BY GS (107 Series,106 Series,etc.)in the same system. *Meets UL 1741 only when installed with IQ System Controller 2 and 3. ID Gateway is required to change thedefault grid CA Rule 21(UL 1741-SA).UL 62109-1.JEEE1547:2018(UL 1741-SB),FCC Part 15 Class B,ICES-0003 Class B.CAN/CSA-C22.2 NO.107.1-01 DATE 7/2/2026 profile at the time of installation to meet the local Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017,NEC 2020,and NEC 2023 section 690.12 and Authority Having Jurisdiction(AHJ)requirements. C22A-2018 Rule 64-218 rapid shutdown of PV systems for AC and OC conductors when installed according to the manufacturer's instructions.ti 2023 Enphase Energy.All rights reserved.Enphase,the a and CC logos,IQ and certain other marks listed at _ (1)No enforced DC/AC ratio. REVISION h"ps://enplie.com/tmm guidelines are trademarks of Enphase Energy,Inc.in the US and other countries. (2)Nominal voltage range can be extended beyond nominal if required by the utility. Data subject to change. IQBMC-MC4-DSH-00049-3.0-EN-US-2G23-10-18 (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQBMC-MC4-DSH-00049-3.0-EN-US-2023-10-18 SIGNATURE PV-6.1 RESOURCE DOCUMENT CONTRACTOR ® ELEMENT ENERGY SOLAR I BATTERY SACKUP,1631.779.79931 E25YS.COM ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN '=k IQ Combine 5 'SC D LIC NO.: 67461-HI, 52689—ME "ENPHASE. Qmm A,.n4 cwaH 01 3]5 cmvd0.6 cmv16.9cm(td.J6'v 135'v4m9.Hd0Mb2 Oe-{535 om)wkh mmn g a� {O Ccmbmer6MmtOGatavvay pY tad chcWtboud lar he0ated rrmnua gentle PV produmbn Ambient lempamture mrge -40'C 10 46'C;-40•F to I15•Fl PROJECT INFO&ADDRESS 101 Lma5(%-b-a,n.JdO-5) —hto(ANS(:[2.10t05'x.).nms:my:tim m-manin0(.]5Y)mnl�Rmmy mein-irn�(•JS`f,7. 6rdude..—W.,ddd.rodefleciheat Qo.EQ tAahael.orvealonpiu—shieW VINCENT CLAPS a,£NFHASE IO Camhuw.-SC Mtn lO GarnvaypdnMrrrt.,in been la intapmfad,avwmwprbdw PV Prafnmim Cnclosuroe,nvonmemalretirg 0-1wr,Mtn- nifiod.NCMA type 3Rpclyee,bmate eomtrvction 10 Combv,a 5C(t-IC-A,41-21.0-5C) meter1,,gMWCQ2D20.5'%).consunpUon monitoring L25%)and lO Battery moniTar'u,0(12.5%). 450 SNUG HARBOR RD, mludes E,0,w Noble e orceac.avlarmodem(eELwoD=JA-IAt-o6-SP-os7'.Irlc"udma Diva zo a to soa treatari�puty u to 4 awO copper mMrctora I ! s.N—dtod.fl—taa[ - GOAbwkm taerrJ,'vpetbte VOAYlO rapperwndretae yNedta to:.VONOG.pe....d— GREENPORT Nesrtral and groun2Mro VOwpPer conductors , :r IQ(-latewarume plaUamla�ota:ar,argy mawgeetenttoTwmpeMrrhe.remote ma'v,renanceand AhaYz lofiowl>ca cod—In.,r-emmmfteco,duaortuk,g IQ 6atewevpdmw dreu;t>b rwugament of the Endtase lO System Bult=m CTRL baartlfor trvedmmmunntionwitRlO Eatter)•5P end lQ Systen CoMm:!er3/3G. NY 11944, USA [a„munca.an On-c,emmcoma�'vitY1 py .—N. egrated Poxer Une Covmvikmien torlO6erk N.icrolevertme 125A Wsbar xitle vpportfor1v10Gatewzy hsa4rork 4v2]q Oraalnr brFmtellmglO Berle: Mzeolmerera endlO Battery SP Atitu's Upto Z600 rtwtei,(8.530fesJ IQesse—'t,nate, CI--W11b a ,,2-pok.101/15A ' � SYSTEM SIZE v-. Pr.duction CT Pmsired reverve q nob so4d Qom CT,aeareh uP,o 0.53, tr;te..W,Fi e102. IV,(duel bend24 GHJ5 GHA.to co-ectirg the Emnese uaue via the—o, _._-�_• 6, X-IQ-AMt-240-5 Can=um—DT Twae�,N�nplenm In,damp,�.hipped wft iha pot,a:��a,atlpro 25% DC SIZE: 11.440 KW DC—(STC) %-IQ-AMt-240-SC wi-Fimngnfmccmmam3d) tom IQ Battery CT ON banes trwtwe,,damp Cl.shooed„hh the b.a,accurate up 1.25X Buvtwt6 eLE42,D m.nnga 1.tonTpar.—Fi stuC AC SIZE: 8.320 KW AC IQ Combine 5 5C CnLtrw4 0-e,ol eardb,virmcwvnartl -m!Osntomccmrdwrs/3Gaadtu1Q6men5p F es[ QpOpyl.WL3.CeJ[(aCa,67V1VL:Mma[caWe(o[ncWed),Ivcomstg,ctrt En;�..M.We Cnma,(oniywith l0 Co. N-SC) 4G-bswd LTE-Mt wbdarrwdmn(CELLMODEM4h-OB-SP-03)Wma 5-Year T-WIA'eats FAan ErpNoC.oudvLOwi:rtenrol The lO Combiner 5/5C consolidates interconnection equipment into asingle enclosure and Smart Act.—,,mkM1 Spare conhol headers for CllL bceM dfobile Corvara CE'_LMOOEM-M)-D6-SP-0So•CEL:LOIIFM-MI-06-A1-05(WClmedw,m iOCortnlrerSC) streamlines lO Series Microirrre,I—nd lC Gateway installation byprovidng a consistent. Includes lO Gateway for GgaaHro Digital np�a/wtpla far'nki Ibunc, l pre-wired soluton for residential applications.IQ Combiner 5/5C uses wired control commurtiatsonandromrd use 2s Far lAetw'a CernoR c.—Hcati-and is—patib!e with IQ System Comrdler3/30 and lQ Batter)5P. btcudes Eaphase Mobile Connect CEL'LMODEM-W-06-Sp-0.5 4G-bamd LTE-Ml,e;ivar ebdem n;ma 5-)ear T-Moh4ecaw plan ICELLMODEM-MI-06-SP-05),onty CELLMOOEN-MI-06-AI-05 4Crhzeel LTE-M)ce!R ,modemMma ST AT&T date plan /•"toss Wk'U`PI—de Foreannoch°r:bmwean thelQG yandamab'cedevice.vnirw ete'rphaze 1n5a1:er0.ry The lO Combiner 5/5C.along with to Series M cromwns-10 System Co7baller 3/3G.and with IC Combine•5C Eua ingpors up'.t corvumptia,Cis one to flotterya and are Producco,of IOB.I.ey5Pprovldesyq,twithacompletagrid-agntemtt Enphase Ertargy System. Suppo•bv Bexbte re iuo�king:Wi-f't Cir.•m beakers(oRah shalt) OwFataErtw eR210.BRTis.eR:20.OR230.0RN0.OR250.arw0R2apcircvueroaterc L kthe0l"or�1116at SuPpav faith BR22C8,EA2s08.and 8R24(H dmd,braskem wmpstitre wen Fa!d-doers k Po.,46mca,vn,ni.agm so-noulz BR.1G 2.2eoV.ORK 15A2 2d0y.0R(-20A 2P 2dgl'.Wa(-15A F-24gV-B.eM 3RIt20d?➢ •Provides procuctionnretering Cirtdttrealers(provided bl Erlpha,e) Zsw-B(Mxedetdb in Ac<essoriea-seCdon) (rave ue grade)4nd consumption vraB,wt Paurte� vraa�le:,or-w.rnma aim nrOdlahry AA-`+("iLAR84lELD-E'i R y�cmnent solar nluald fw 10 Cc+vbe,ar 5/SC Lord APl Rafmtogtida brbealAR AA-ENV2-PCBA-5 IQ Gavway rep[,.—pimec d ,boord CPCB)for Cmnbine,5/5C Etsy to Innudl It X-IPtJA-ND-12S1 Hdd-tbwnkit:ompaLLle mtF Eaton BR-B-i.cir.11'ea)en(with 1—) 10—te,cr UL I741,CAN/CSA C=No.102.L Hac 47_M Pa-t IS Cl..B.ICES 003 IQS.d.Miroinnan-ers IQSyslem Cmm.IIer3/3G Mounts to one stud with centered Thshign-la •edsmartgrid-readylOSerxs Pmvid%microgrid intercatneetion brackets UL 60E0FdCANCSA:22Ne.610'0-1 IEEEEt 7;20)8(UL174�5R3`Ed7 NGaoinrnr 1—(106.I07-and 1085e,tes) device(MID)I...Uuna'ity by Su 'te bottom,back,and side Ra[ f10A bC'ato'e'aY IEEE 2030./CBm Oompnwt diamatkally eimpr,-y the installation process —taottiodly detecting grid fell—sand pPo'• ' Production me'edrg.ANSIC1220amrery dus OS tPVPraductoN ta,duh entry eamlessly bemitietina the home era I20 gy Bvswmvdtege /240 VAC,60 Nz system from grid pcve-to backup pourer Suppo-ks up W four 2-pole branch circuits to'240 VAC plug it breakers 6us6u,at'vy =A IO System Ccnhdlm3/3G SC2000I11024OUSOL SC2OOGmC24JU501 (not Included) Faun curemrabag 10 iAIC (---- IQ Batt%SF IOBAt1ERY-5P-IP-NA aOAtotal PV—chtircuib_ vsnm 1 , Mumun arRnw,acvrer,re•up Cmp tfr.m PJhlcnge) 54a 1tic,oin 106.10).a,M1095aiav Mz+dmerters •:� mt 6lueasy Wi F—W-Fi provmoning toreary W(-F Setup BrarcncrcWts(soar aEtl/.•smraga) Up to toor21sde Eeion eR wrhsdizuburetl gar,astron(DG)croakars ony Wtmcludad) Muknw,toa.bvxh ucua broalm rateg(input7 BOAddrsbburodg—atiaN95A stm.0 Gatflxvy breai—ILdec t Reliable to Ga[eway orea'ver 10 A or 15 A sung GE/S.—/Eaton included L� •Durable NRTL-certiNed NEMA type 3R enclosure Prodzpan meiedm,CT 200Asoadco-a p,e-4staHed arq M.•ad Lo IOGa[e,-rav IQBatt.'Sp IQ Load COntrollor Cmm� CT CT 20]-(}AMo) 4 121N1acin. f urluAad with kw hoc Fully integrated AC baton,system.includes au Helps prloriHI,essential appllsnces S-yearlimted warranty mmLT mx+ihxing (.- Pn'vo �g+-uyl.mcrw,a hams ame,sn field-replaccable 106D-BAT Micrbimettem dining a End omega to WIi. T..years labor reimbursement 10 Batut,netermg CT 203A ctamc-atNo cub-uandomm 1.,lO Battery matarinR.imludedvnth the box rnrgy cons0 land prolong program—,age irdudad for both battery rile the)Q Combmer SKUs •UL17411isted LISTED 5-year Gmned usvv,.,hw.,wheeheba,ac n.a+w.,at+dmottr„•suA„nn.ea) ants ®2023 Enphase Energy.ail tghn reserv<tl.Enpyase.the a cad CC bgm.IQ aMee-[aia otter nark.IS:ed et Fm�s�//er�f,ve.com.hmfenvravax.,dde:`n,m a,e hademeraad Cnphe:e Cnergy.L In datF u:d e6wrwwnriea. Date wbj—b cn.Ne- ILr.8 5C-DSiiUWOt.}D.FN.I6-2023-OD-D rCL-}SC-051!W00]-3fiFNiF30iH'?-21 N_-SSC-JSN-0OCCT-�O-FfIUS-ZOl3{p.31 DRAWN BY GS DATE 7/2/2026 REVISION SIGNATURE PV-6.2 RESOURCE DOCUMENT CONTRACTOR inIRONRIDGE AIRE RAILAlELEMENT ENERGY SOLAR BATTERY BACKUP1631.779.79931 E2SYS.COM ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11952, USA 1 +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN LIC NO.: 67461-1-1I, 52689-ME PROJECT INFO&ADDRESS VINCENT CLAPS 450 SNUG HARBOR RD, GREENPORT, NY 11944, USA ITEM NO DESCRIPTION QTY IN KIT SYSTEM SIZE 1 Aire Rail, Al, Black(or Clear), 170 1 DC SIZE: 11.440 KW DC-(STC) AC SIZE: 8.320 KW AC Part Number Description AE-Al-170M AIRE RAIL, Al, MILL, 170 1) Aire Al 1.40 1.17 170 1.38 1.70 1.04 0.22 DRAWN BY GS DATE 7/2/2026 Part Number Material Value REVISION AE-Al-170B 6000-Series Aluminum Black SIGNATURE AE-Al-170M 6000-Series Aluminum Clear PV-6.3 v1.0 RESOURCE DOCUMENT CONTRACTOR ELEMENT ENERGY SOLAR I BATTERY BACKUP 1 fi31.7T9.79931 E25YS.COM IRONRIDGE Aire Flush Mount S stem Rails Y ELEMENT ENERGY LLC AireT1A Al Rail Aire'A2 Rail Airel Rail Ties AireTm DockT1 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN LIC NO.: 67461-HI, 52689-ME The lighter,open AireT"" The tougher,open Aire T"" Structurally connect and Connects AireT"" Rails to rail for standard conditions. rail for higher load capacity. bond AireTm Rails together. attachments with ease. 6'spanning capability 6'spanning capability Reinstallable, up to 5x Clicks on,slides easily PROJECT INFO&ADDRESS Wire management tray Wire management tray Internal splice design Drops into open slots VINCENT CLAPS .. i • Mill or anodized black Mill or anodized black No more splice rules • Anodized assembly 450 SNUG HARBOR RD, -� GREENPORT, Clamps&Grounding NY 11944, USA Airelm Lock Mids AireT1 Lock Ends AireTm Lock StealthT" AireTm Lug _ SYSTEM SIZE i` �' ANN* DC SIZE: 11.440 KW DC-(STC) AC SIZE: 8.320 KW AC , Securely bond between Securely bond modules to Securely bonds modules to Bonds AireTm Rails to modules to AireTm Rails. Aire'" Rails along ends. rail ends,entirely hidden. grounding conductors. • Fits 30-40mm modules Fits 30-40mm modules • Angled for easy install Simplified with single bolt • Utilizes UFO"design Easy rail engagement Robust tether leash Low-profile form factor • Minimal 1/2"gap Clean aesthetics Fits most modules Works with 10-6 AWG Breathe easy With accelerated installations. Accessories The Aire- racking system has been carefully crafted to streamline every part of the installation process,taking out all of the tiresome hassles—so that you get off the roof and on to your next project faster than ever. Aire'Caps AireT'Clip AireTm MLPE Mount Aire'All Tile Hook Aire"" retains the strength and reliability that IronRidge installers have come to depend on.Whether you're a seasoned installer with years under your belt or just getting started in solar, breathe easy. 'Wool- Strength Tested PE Certified All components have been evaluated Pre-stamped engineering letters are Block entry and provide a Keeps wiring contained in Securely bonds MLPE and Attaches rails to tile roofs, for superior structural performance. available online for most states. finished look to AireTM' Rails. open AireT" Rail channels. accessories to AireTm Rails. with Aire'" Dock included. • Stay secure on rail ends No module interference Glove-friendly installation Works on flat,S,&W tiles • Symmetrical,with drain Simple press-in design Lays flush in rail channel Single-socket installation Class A Fire Rating Approved Cable Tray Cover rough-cut ends Slot for easy removal Low profile form factor Optional deck flashing Certified to maintain the fire resistance Open rail channel conforms to NEMA rating of the existing roof structure. VE 1, certified to hold PV cables. Resources Design Assistant "so,•,, Approved for FL Hurricane Zones s F °TAP % DRAWN BY GS UL 2703 Listed System 25-Year Warranty - Quickly go from rough layout +40, „°�* Aire"'has Florida Product Approval. to fully engineered system. =�i` 2_ Additional details can be found on the DATE 7/2/2026 Entire system and components meet Products are guaranteed to arrive "x` W^T°F ti Florida Building Code website. Go to IronRidge.com/design =`2' , .���' g the latest effective UL 2703 standards. without any impairing defects. ryH Learn More at bit.fy/florida-sire REVISION SIGNATURE PV-6.4 RESOURCE DOCUMENT CONTRACTOR JEli ® ELEMENT .y. ENERGY SOLAR BATTERY BACKUP1631.779.79931 E2SYS.C13M .160- -w IRONRIDGE Bonding Hardware AaL IRONRIDGE Grounding Lug ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME 3 3 IMPROVEMENT, MASTER 2 1 ELECTRICIAN 1 3 LIC NO.: 67461-1-1I, 52689-ME ® ® 2 PROJECT INFO&ADDRESS VINCENT CLAPS ITEM No. DESCRIPTION 450 SNUG HARBOR RD, 1 BOLT,T CSTM,3/8-16 4 GREENPORT, 2 BOLT, BONDING 3/8-16 SQ HEAD ITEM NO. DESCRIPTION NY 11944, USA 3 NUT, BONDING STEP 1 LUG,GROUNDING,LAY-IN-LOW PROFILE 2 BOLT, 1/4-28 X.750"HEX CS SST SYSTEM SIZE BONDING HARDWARE 3 NUT, FLANGE HEX 1/4-20 SST DC SIZE: 11.440 KW DC-(STC) 4 BOLT,T CSTM 1/4-20 X 1.188"LOCK SS AC SIZE: 8.320 KW AC Part Number Description BHW-TB-02-Al T-BOLT,BONDING HARDWARE Part Number Description Wire Size Range(AWG) BHW-SQ-02-Al SQUARE-BOLT,BONDING HARDWARE XR-LUG-03-Al GROUNDING LUG,LOW PROFILE 4-10 1) BOLT, T CSTM, 3/8-16 2) BOLT, BONDING 3/8-16 SQ HEAD 1)Lug,Grounding 3) Nut, Flange Hex 1/4-20 C82 1.00 17 +� 1.00 .63 3/8-16THD 4- I .63 •71 1/4-20THD_ �•59 .36 .56 n �}J 24 0.26 7/16"Head - .24 .29 3/8-16 THD Property Value Property Value Property Value Material 300 Series Stainless Steel Property Value Material 300 Series Stainless Steel Material 300 Series Stainless Steel Material Tin Plated Copper Finish Clear Finish Clear Finish Clear Finish Clear Matte 4) Bolt,T CSTM 1/4-20 x.750 3) NUT, BONDING STEP -24- 1/4-20THD 3/8-16 THD 2) Bolt, 1/4-28 x.750 Hex 0.75 I .61 7/16' -►I �-.16 ® Head 1/4-28THD — .75 7116"Head .75 26 Property Value Property Value Property Value Material 300 Series Stainless Steel Material 300 Series Stainless Steel Material 300 Series Stainless Steel Finish Clear Finish Clear DRAWN BY GS Finish Clear DATE 7/2/2026 v1.30 v1.10 REVISION SIGNATURE PV-6.5 RESOURCE DOCUMENT CONTRACTOR ELEMENT '^ ® ENERGY SOLAR(BATTERY SACKUP1631.779.79931 E2sYsxm ELEMENT ENERGY LLC -Qi. IRONRIDGE End Fastening Object AMIL IRONRIDGE Universal Fastening Object® 7470 SOUND AVE, Only for installation and use with IronRidge products in MATTITUCK, NY 11952, USA accord with written instructions see IronRidge.conUUFO +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN e LIC NO.: 67461-HI, 52689-ME PROJECT INFO&ADDRESS / - VINCENT CLAPS 450 SNUG HARBOR RD, UNIVERSAL FASTENING OBJECT' GREENPORT, NY 11944, USA PART NO. DESCRIPTION SYSTEM SIZE UFO-END-01-AI END FASTENING OBJECT(END CLAMP,30-40mm),MILL DC SIZE: 11.440 KW DC-(STC) UFO-END-01-B1 END FASTENING OBJECT(END CLAMP,30-40mm),BLACK AC SIZE: 8.320 KW AC 1 .43 L—1.0 ITEM NO. DESCRIPTION UFO-CL-01-Al UNIVERSAL MODULE CLAMP, CLEAR UFO-CL-01-B1 UNIVERSAL MODULE CLAMP, BLACK .39 � I 1.27 COMPATIBLE WITH .58 30-40mm MODULE FRAMES 2 .29 �7/16"Head .61 25 COMPATIBLE WITH 37 tic 30-46mm MODULE FRAM 1.0 ES 0 1.12 7/16"HEAD S . O .25 Property Value ITEM NO. MATERIAL FINISH Material 300 Series Stainless Steel 1 6000 SERIES ALUMINUM MILL OR BLACK Finish Clear and Black 2 300 SERIES STAINLESS STEEL CLEAR AND BLACK DRAWN BY GS V1.0 0.32 DATE 7/2/2026 REVISION SIGNATURE PV-6.6 RESOURCE DOCUMENT CONTRACTOR W11 ELEMENT ENERGY SOLAR I BATTERY BACKUP 1631.779.79931 MYS.COM ELEMENT ENERGY LLC IRONRIDGE QuickMounV Halo UltraGrip 1.Halo UltraGrip .38 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN LIC NO.: 67461-HI, 52689-ME PROJECT INFO&ADDRESS 3.35 RD STRUCTURAL SCREW PN RD-1430-01-M1 VINCENT CLAPS ^ SOLD SEPARATELY \ SHOWN FOR REFERENCE 450 SNUG HARBOR RD, GREENPORT, NY 11944, USA Release Liner SYSTEM SIZE shown for reference DC SIZE: 11.440 KW DC-(STC) AC SIZE: 8.320 KW AC 3.83 0 0 0 .40 �.26 O 1.63 1i (/ T 1.56 I ITEM NO DESCRIPTION QTY IN KIT 1 QM Halo UltraGrip(Mill or Black) 1 O O 34 PART NUMBER DESCRIPTION QM-HUG-01-M1 Halo UltraGrip-Mill QM-HUG-01-B1 Halo UltraGrip-Black 3.00 Property Value Material 300 Series Aluminium DRAWN BY GS Finish Mill or Black DATE 7/2/2026 Q 20221ronRidge,Ihc.AII rights reserved.Visit%~v.ir-paten!s.com for patent information. QWHUG-01-BI or QM-HUG-01-Ml Cut Sheet Rev 1.0 ©2022 IrorRidge,Inc.All rights reserved.Visit wJr-palents.corn for patent Information. QM-HUG-01-Bl or QM-HUG-01-Ml Cut Shee;Rev 1.0 REVISION SIGMA-URE PV-6.7 RESOURCE DOCUMENT CONTRACTOR IRONRIDGE QuickMounr RD Structural Screw ELEMENT l ENERGY SOLAR I BATTERY BACKUP 1631.7713.79931 EZSYS.COM ELEMENT ENERGY LLC 7470 SOUND AVE, t MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN LIC NO.: 67461-HI, 52689-ME PROJECT INFO&ADDRESS VINCENT CLAPS 450 SNUG HARBOR RD, GREENPORT, NY 11944, USA ITEM NO DESCRIPTION QTY IN KIT 1 Self Drilling Screw,#14,Wood Tip 1 SYSTEM SIZE 2 Washer, EPDM Backed 1 DC SIZE: 11.440 KW DC-(STC) AC SIZE: 8.320 KW AC PART NUMBER DESCRIPTION HW-RD1430-01-M1 RD Structural Screw 1.Self Drilling Screw,#14, Wood Tip •22 #14 DIA 5/16" Head .0.43 3.00 Property Value Material 300 Series Stainless Steel Finish Clear 2.Washer, EPDM Backed .13 0.26 0.57 DRAWN BY GS DATE 7/2/2026 Property Value REVISION Material 300 Series Stainless Steel Finish Clear SIGNATURE PV-6.8 C 2022 IronRidge,Inc.All rights reserved.Visit WNW.ir-patents.com for patent Information. CM-HW-RD-1430-01-M1 Cut Sheet Rev 1.2 RESOURCE DOCUMENT