Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
51840-Z
�oy��of s°ulyo�c Town of Southold * P.O. Box 1179 oQ 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47087 Date: 05/26/2026 THIS CERTIFIES that the building SINGLE FAMILY DWELLING-ADDITION AND ALTERATION Location of Property: 780 Windiammer Dr Southold, NY 11971 Sec/Block/Lot: 79.4-10 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 03/10/2025 Pursuant to which Building Permit No. 51840 and dated: 04/18/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "As built" alterations including a finished basement with a bathroom and wet bar (no bedrooms) to an existing single-family dwelling as applied for. The certificate is issued to: Lawrence Burke ,Erin Burke Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51840 1/9/2026 & 7/17/2025 PLUMBERS CERTIFICATION: William Schwamb Plumbing & Heating Inc 01/07/2026 Au orized Signature hoAoFso&,yo(o TOWN OF SOUTHOLD BUILDING DEPARTMENT • �� TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51840 Date: 04/18/2025 Permission is hereby granted to: Lawrence Burke PO BOX 667 Southold, NY_11971 To: construct additions and alterations and to legalize an "as built" basement stair reconfiguration to an existing single-family dwelling as applied for. Additional certification may be required. Premises Located at: 780 Windjammer Dr, Southold, NY 11971 SCTM#79.4-10 Pursuant to application dated 03/10/2025 and approved by the Building Inspector. To expire on 04/18/2027. Contractors: Required Inspections: Fees: Single Family Dwelling- Addition &Alteration $931.00 As Built Alteration $30.00 CO-RESIDENTIAL $100.00 Total $1,061.00 --- -------------------- Building Inspector ho��pF SO�Tyol Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • Q Southold,NY 11971-0959 �O �y�4UNTY,Oc� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Lawrence Burke Address: 780 Windjammer Dr city: Southold st: NY zip: 11971 Building Permit#: 51840 . section: 79 Block: 4 Lot: 10 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Electrician: North Fork Electrical Contracting License No: 2300ME SITE DETAILS Office Use Only Commercial Indoor X Basement Service X Solar Residential X Outdoor X 1 st Floor Pool Battery Storage As-built Renovation 2nd Floor Hot Tub EV Charger New X Addition Attic Spa Generator Survey Mezzanine F7 Garage Dock INVENTORY Service 1 ph In-wall Heater Recpt Ceiling Fixtures Smoke Detectors Pump Service 3 ph Hot Water GFCI Recpt Wall Fixtures CO Detectors Heater Main Panel 200 A/C Condenser Single Recpt RecessdFixtures Combo Smoke/CO Transformer Sub Panel A/C Blower Range Recpt Ceiling Fan Heat Detectors Salt Gen Transfer Switch 200 Mini Split Dryer Recpt UC Lights Fridge AutoCover ARC Blower Heads Switches Pucks Lights Dishwasher Mini Fridge GFI SepticDisconnect Emrgency Strobe 4'LED Microwave Garbage Disp. ARC/GFI ERV Exit Lights Bath Exhaust Hood Dehumidifier Other Equipment: 200A Panel 40 Circuit/36 Used Notes: Service Inspector Signature: Date: January 9, 2026 pF SOUr�,ol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q Southold,NY 1 1 97 1-0959 r0 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Lawrence Burke Address: 780 Windjammer Dr City: Southold St: NY Zip: 11971 Building Permit#: 51840 Section: 79 Block: 4 Lot: 10 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Wolf Brothers Electric License No: 70124ME SITE DETAILS Office Use Only Indoor 57 Basement Service (— Solar F Outdoor 1st Floor (— Pool F Spa r Renovation F 2nd Floor F Hot Tub r Generator 17 Survey (— Attic r Garage Battery Storage r INVENTORY Service 1 ph F Heat Duplec Recpt 26 Ceiling Fixtures 1 Bath Exhaust Fan 1 Service 3 ph F Hot Water GFCI Recpt 6 Wall Fixtures 2 Smoke Detectors 2 Main Panel A/C Condenser 1 Single Recpt Recessed Fixtures 20 CO Detectors Sub Panel A/C Blower 3 Range Recpt Ceiling Fan Combo Smoke/CO 2 Transfer Switch UC Lights Dryer Recpt 30A- Emergency Strobe Heat Detectors Disconnect Switches 16 4'LED 2 Exit Fixtures Other Equipment: Mini Split Ducted Notes: Finished Basement Inspector Signature: X l Date: July 17, 2025 Sean Devlin J Electrical Inspector sean.devlin(C_town.southold.ny.us 780W indjam merBasement i t ' Town Mall Annex Telephone(631,7ti5 18i17.. h .. 54375 Main,Road -M i P.0.Bor. 1179 4 I Southold,NY 11971-0959 Ile- BUILDING DEPARTMENT TOWN OF SOUTHOLD I CERTIFICATION I Date; I.3uildill" Permit No. _..._....................... ................................................. .. Oii'I1C1': ("Please print) Plumber:W 111:1Q.V'Yl...._`�n�U_ILU�1�?_.._`Y�IAkY1�................�.!fit ,1 n C (Please print) I certify that the solder used in the water supply S}'SICill COIltilillS ICSS than 21"10 ul• I";, lCdd- I (I'luillbers sil-1)a1+.1re' Sworn to bet'ore nle this dais of•... 0 LL.Q Nol:uy PGlhlii;&1.*..W--�,,Uffly J Ate 9 2026 KIRSTEN E.HESPOS Department Notary Public State of New York g rovjn n9of Southold No. 01 HE6174810 � ToW Quaiiried in Suffolk County Commission Expires 09/24/202-1 �o��pF SOUTyoloa '►� cn� T WN OF SOUTHOLD-BUILDINGDE -OU 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR . [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [. ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [. ] RENTAL REMARKS: 04 DATE �5- 212Z-;--- INSPECTOR ` �O,*Of 50Ulyo� # # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 �gl� o INSPECPON [ ] FOUNDATION 1ST [ ROUGH PL13G. [ ] F NDATION 2ND [ ] INSULATION/CAULKING" [ FRAMING./STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY` - [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANTZONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: . w1vt oloawv r) C- DATE INSPECTOR 0E S0UTyO� 51&L-tc 78,0 4 # # TOWN OF SOUTHOLD BUILDING DEPT. cou 765-1802 INSPECTION [ '] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS:I\A arvp"ICT r C� :f t3 Pi;ry uc-,>) r V r DATE INSPECTOR s.. ; �OF 50Ulyo# y TOWN OF SOUTHOLD BUILDING DEPT. o � 631-765-1802 I NSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] R UGH PLBG. [ ] FOUNDATION 2ND - [ INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE-RESISTANT CONSTRUCTION [ ] .FIRE RESISTANT:PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [: ] RENTAL REMARKS: c. i rSV h-D BLS �� lam• /�-l3 /1Sf�� c awInudl000m %t DATE INSPECTOR SOUly�lo - # TOWN OF SOUTHOLD BUILDING DEPT. couto, 631-765-1802 : INSPECTIONS [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. - FOUNDATION 2ND [ ] I ULATIO�WCAULKING [ ] FRAMING /STRAPPING [ � FINAL lip, ?" [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION : [ ] .FIRE'RESISTANT PENETRATION [ ] ELECTRICAL,(ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [. ] RENTAL REMARKS: D004 Alamo 61s C as UGaol? ��� �o�- /ns l� we s�i � bu4Le,z 946e5s oqAd oemAotle, beds 4,fm Aoiu e ® icy /-'of An- sL ca ull 7�/rrmc�l DATE 7./ o?� INSPECTOR AoOF SOblyOlo e;l v ( -76 0 Wi-id, - # * TOWN OPSOUTHOLD BUILDING ,ouffv, 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]. RENTAL REMARKS: N r=OP AJ 6W 0EL 77Rl(A,,- FAAJ J�-t,, DATE INSPECTOR pF SOUTyOIo 0 # . # TOWN OF SOUTHOLD BUILDING DEPT. �[ coum, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [Aj/'FINAL [ ] FIREPLACE& CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Ag&A �d GPA (A o--in,- COA) DATE INSPECTOR �OOF SOUTyOIo `-) - - _7 � n � -- # # TOWN OF SOUTHOLD BUILDING DEPT. coorm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/.REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [. ] FIRE RESISTANT CONSTRUCTION { ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) - [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: ��� f 69 / C c� DATE I INSPECTOR Oyster Day Drafting and Architecture, P.C. G8 W. Main 5t. Oyster Bay, N.Y. 1 1 771 Tel.: 5 1 G-922-597G Fax: 5 1 G-922-G235 www.oy5terbayclraftine.com April 3,2026 Town of Southold Building Department r ,f, 53095 NY-25 j Southold,NY 11971 Att:Nancy Meyer,Building Inspector j is MAY 2 U 2029 Re; Burke Residence 780 Windjammer Dr Department Southold,NY 11971 7c;-,in of Siluthold Re:Finished cellar and partial garage conversion to Dear Ms. Meyer, This letter is to certify that the project has been inspected by us at critical stages.We have inspected and are certifying the insulation,fire caulking,framing and finished work and they meet or exceed the 2020 NYS Residential Code. We are certifying that all the work performed meets or exceeds all the requirements of this office and the Oyster Bay Drafting/Town of Southold approved plans along with the NYS Residential Code. Please let us know if there is any further information you need.Thank you. Sincerely, Al � Dennis Mele,R.A COMMENTS FLELD INSPECTION REPORT D ATJ .......... CD FOUNDATiON (IST) -------------------------------------- ----- --------- ...... 87c FOUNDATION (2ND) ....... 100-1 ROUGH FRAMING & --------- PLUMBING _awl Pt m eld v INSULATION PER N. Y. STATE ENERGY CODE eM-a Ve, A? hate- jeMie,�- �h OLS 4 _,ba InSulo-be-9t .e FINAL Aj il e Ae ADDITIONAL COMMENTS eD 0 100 m X _Iac ___l ---------- ------- IA6 ...... CA x g15FF01p COGy� TOWN OF SOiT HOLD -BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 �y�o• �a�l Telephone (631) 765-1802 Fax (631) 765-9502 hLtps://www.southoldtowm.gov Date Received APPLICATION FOR BUILDING PERMIT V i('' r For Office Use Only ru MAR 10 2025 1 PERMIT NO. Building Inspector: Applications and forms must be filled out in their entirety. Incomplete 70VA1 of goUl'iiold applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form (Page 2)shall be completed. Date: OWNER(S) OF PROPERTY: Name: Eltid ISV(Llc1 SCTM# 1000- -7&T 4 - 1 � Project Address: $d w{two Tor Mour1- P1r- • �o�-F-�IoL,fl 1 N:f � I R71 Phone#: �3� " (.g) $110 Email: 'fjVf-PEHoL.Piags PR GJ (! m-A-iL..Wh Mailing Address: 15OM 1 CONTACT PERSON: Name: 5c-04- 1L-NtJ Mailing Address: (�$ (�, v%,OH tJ !,�'-, py S1ef' 13�•`-( 1 1J•`0• Jill j Phone#: 5-19 7(0 X -13 E m a i I: 1 tJ1=o e o y S t.F-st-V-"p I+.s►-f-c-1N4 , (,e�N'1 DESIGN PROFESSIONAL INFORMATION: Name: DCty tom►(S M E k E-) IZ.oA-. Mailing Address: (o$ lJ. M A-t tJ Sfi• b ti I'f��- $ 1 IJ -(, ( (17) 1 Phone#: 17- - 911 %. X -to 7E—mail: 4rpe4A 11,e "ep�jST�tt-8«�^1 .Coto CONTRACTOR INFORMATION: Name: �To S Fr H G u SV M A-M Mailing Address: _Je- J3.&1-t- r44 (-t��.l.ol /� t-J-(. WTP)3 Phone#: (P 31 ,. '02 4,791 Email: 1-05, rtl GuS t t %AA-N- ( � G�'►��• DESCRIPTION OF PROPOSED CONSTRUCTION []New Structure ❑Addition VAlteration ❑Repair ❑Demolition Estimated Cost of Project: El other $ gs� t700 Will the lot be re-graded? ❑Yes No Will excess fill be removed from premises? ❑Yes N< 1 PROPERTY INFORMATION Existing use of property: �_ �A,N1 Pwc-LA-t t4� Intended use of property: O b.M4 Zone or use district in which premises is situated: Are there any covenan tsnd restrictions with respect to this property? ❑Yes IF YES, PROVIDE A COPY. Of Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): ❑Authorized Agent L/Owner Signature of Applicant: Date: STATE OF NEW YORI<) SS: COUNTY OF 4OFf!F ) l;?4&j �y r-1-1co being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S),he is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of �'4 A 20 2S NoERJANWARRA NOTARY PUBLIC,STATE OF NEW YORK Registration No.01LA6140880 ualified in Suffolk County PROPERTY OWNER AUTHORIZA Baission Expires February 13,20 (Where the applicant is not the owner (�VFy-lc- residing at -790 Li �r��"�•x�e` �I`- 4CN do hereby authorize 5LcP,}— {r— '� to apply on my behalf aown of Southold Building Department for approval as described herein. wner's Signature Date F-14J 5Wv Print Owner's Name 2 Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) I V�tj PVC residing at ? (Print property owner's name) I (Mailing Address) ,5o O--M btu do hereby authorize cjGd 44- 14-A- , . (Agent) to apply on my behalf to the Southold Building Department. .ter 2� (O ner s Signature) (Date) eft-(t-i p>yf- c� (Print Owner's Name) SUFFO ILDING DEPARTMENT- Electrical Inspector �O �„ TOWN OF SOUTHOLD y a APR �o all Annex- 54375 Main Road - PO Box 1179 ^ Southold, New York 11971-0959 uile niq TySrlal",,telephone (631) 765-1802 - FAX (631) 765-9502 ToWn 64 % MeshAsoutholdtownny.gov - seandAsoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 4/23/25 Company Name: wolff brother's electric lie Electrician's Name: Gregg Wolff License No.: ME-70124 Elec. email:wolffbroselectric@gmail.com Elec. Phone No: 516-6934855 01 request an email copy of Certificate of Compliance Elec. Address.: 2 plymouth dr. massapequa,ny 11758 JOB SITE INFORMATION (All Information Required) Name: Burke Address: 780 Windjammer Dr. Southold, ny 11971 Cross Street: Anchor Ln. Phone No.: 516-693-4855 Bldg.Permit#: 51840 email: Tax Map District: 1000 Section: -] Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Basement: (2) rooms,(1)bathroom, main area Square Footage: I i000 Circle All That Apply: Is job ready for inspection?: YES❑ NO ❑✓ Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES 0 NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect[-]Service Reconnect❑Underground❑Overhead #Underground Laterals 1 FJ2 M H Frame Pole Work done on Service? 0 Y MN Additional Information: PAYMENT DUE WITH APPLICATION C V I yO UFFO l ILDING DEPARTMENT- Electrical Inspector Gr��p� ji TOWN OF SOUTHOLD 2025Toall Annex- 54375 Main Road - PO Box 1179 coo Southold, New York 11971-0959 � 0` elephone (631) 765-1802 - FAX (631) 765-9502 o -Fa�,%Jej C;7 isC', esh(c�southoldtownny.gov -- seand@southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 4/23/25 Company Name: wolff brother's electric Ile Electrician's Name: Gregg Wolff License No.: ME-70124 Elec. email:wolffbroselectdc@gmail.com Elec. Phone No: 516-693-4855 01 request an email copy of Certificate of Compliance Elec. Address.: 2 plymouth dr. massapequa,ny 11758 JOB SITE INFORMATION (All Information Required) Name: Burke Address: 780 Windjammer Dr. Southold, ny 11971 Cross Street: Anchor Ln. Phone No.: 516-693-4855 Bldg.Permit#: 51840 email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Basement: (2) rooms,(1) bathroom, main area Square Footage: -1 i000 Circle All That Apply: Is job ready for inspection?: YES❑ NO Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES 0 NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 F12 H Frame Pole Work done on Service? Y FIN Additional Information: PAYMENT DUE WITH APPLICATION C1V I t�aaQ � 1� 1 PERMIT# Address: a Switches - Outlets GFI's Surface Sconces .� H H's UC Lts Fridge HW POOL Fans Mini Fr. WAD PanelPump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower 1 1&7& AW Hood lower 1C� Service Amps Have Used Sub Amps Have Used Comments r ,l z-n r "SUEFO(,� r BUILDING DEPARTMENT- Electrical Inspector DEC 3 2025 TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 ' Southold, New York 11971-0959 Telephone (631) 765-1802 i APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: tj 2 ( 12-47— Company Name: K CC Electrician's Name: Ste, License No.: lz-;s fM L EleL email: S �, O� Elec. Phone No: 3 t- 2 Z ❑I; request an email copy of Certificate of Compliance Elec. Address.: Alf JOB SITE INFORMATION (All Information Required) Name: J &--►-aeA) Address: V(> W ti Aj mew V-n ty Cross Street: A)C ey Phone No.: C[1rl —V:�, l Bldg.Permit#: rjfg ]- D email: (, iN w�l���� .Cam Tax Map District: 1000 Section: Block:y Lot2• BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: YES N Rough In Final Do you need.a Temp, Certificate?: YES 0 Issued On Temp Information: (All information required) Service Size❑1 Ph❑3.Ph Size: A # Meters Old Meter# ❑New Service0 Fire Reconnect[:]Flood ReconnectOService Reconnect[]Underground[]Overhead # Underground Laterals D 1 2 H Frame D Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION PERMIT# Address: Switches Outlets G F I's Surface Sconces H H's UC Lts Fridge HW. . POOL Fans Mini Fr. W/D ..Panel Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Sala.Gen. Water Bond Carbdn^ M.i.cro G,rb.Dis Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo % Cooktop Minisplit Blower AC AH Hood Blower Service Amps '9, 2- Have O Used -27 4 Sub Amps Have Used Comments y U- r I' `_ ��rzrr1 Town Hall Annex ��� Gy Telephone(631)765-1802 54375 Main Road c Fax(631)765-9502 P.O.Box 1179 y Southold, NY 11971-0959 Q • BUILDING DEPARTMENT NOTICE OF UTILIZATION OF TRUSS TYPE CONSTRUCTION, PRE-ENGINEERED WOOD CONSTRUCTION AND/OR TIMBER CONSTRUCTION Date: Owner: U Pr-� Location of Property: !,0--Wo LD f N-Y. Please take notice that the (check applicable line): New commercial or residential structure Addition to existing commercial or residential structure Rehabilitation to an existing commercial or residential structure to be constructed or performed at the subject property reference above will utilize (check applicable line): Truss type construction (TT) Pre-engineered wood construction (PW) Timber construction (TC) in the following location(s) (check applicable line): Floor framing, including girders and beams (F) Roof framing (R) Floor and roof framing (FR) Signature: Name (person submitting this form): ca#—K-9+:WAJ A76� Capacity(check applicable line): Owner Owner representative TrussRegl5.docx Effective 1/1/2015 ,,1�'• C'1. .~4' .'R�1Vt•• ,S�v" , ..t.r•...._...o..w...,..r+�..•..rM•.+..ww�w��.w••..��✓nwr.Y+�••�'�'T�'o''�^�T..' , • OUNTY HEALTH DEPARTMENT ..,6..:v. Y.+� 1977 H. D. . :;,In`^+. _ ? '� � , � .,. ...,- ietiee disposal and water supply 3.li s for this location have been ' �CS� ,F An"ected by thi, departm.ent and found ;to llbe satisfactor : C3 "�6 w .' Chief of Genera. Engineerii •• 1 ' ,� r ('1 T t�,. p� I �t-0 r 11 l+J� r -4 r ta CCC ` \ 1 Ap +{�• � rye t •+ 1�L`� y _ g cot PA 35 J-q •' ! fir. t I+eOT- tiA;• � 1 1YSrnl%iJ;{:�t:l�i:'fl i1L`ifR�.ftON•Qk�eFlvef?�wt+�++""' . •' �t l!CTfG'•1 ?^,C9 43F T1?! AlF�b' PORK•5TA7E •� .• f , � DUCA'flvtJ 1,At.V. I pE'I�.'. <:•': Tli:': `f Ve%v NOT VARiNq >� ..... .t a e � .r{e L.^,.., J�:.':1':"';�i:'::.:�•,��A,L GiR LL-RUM G� yfY: t tt t, t' I ; APIO • ;�1,ta1 LTG li-I: . ,.:,; •t:::5 ;�• '.,.. :�'..:�<^, S:V;'il•• I y fPUTiO! . C:•.:r1.li.4Slf:.5 •t>1'CYD ^iSF:RA3iE ' ���• . '. •�• .,i ,, :�%L,. C VA;,f•N r ' �,O AD�IMVNA: Iss!,1�-UfIONS OR 5'J3Ec pWNE11S. t Tr t Lai�1 • ,+a r �r<:...1' Xk .'41 '.>, ,.i�. �.' {�1..,�. r ,,.t•N ± :;s..t: .Nt, yMs�.: �1, T•h. `Y: .. SVa-,'1�^'d:'.� :,•� hAq �!'�y!� {.�•,t, ,� � ,�r� p••M'n /'��tr � 4 ,. t`�'�� Y'"(.fl��• :ri-�,W�'t'•`>�'1i.•?'."'.. ', �'?�:t`.� ��,j�J�t{y yyyY,' jy1�gy •' � ` ,�/�l ''' � .• i -. ..a.�y},rr��,.,w�.,,,w}M. 9rJ.�', y ,(�Y�yy��. , ��,.iY�^�''� y.":..� ..i: '�[`/v1�" � '�•C,:�.7 �r•Y � \ �•t'�Y��'.l.l"'y 1'R'��W.. 'Y'+\'. 1J• ' '' ..15 rI � •/i�l.'.,',.j (p(!�'y W]�jy�.�(y,� �(yI•♦� µ wn...I y� ����'.r. �. �y •I� .L. q •:,.•'�:.:''� '•.,"'�+ _w•.+w—_..w•�•Mr•..•.,,�.•w.......77 �"yt•,, y[� w.rw•nw.�r. :Yi,", '. ��1�'4"1 !' .b.�.r.+«..•nw�!N.MrMI•+••...'rr.• �v...«wa•+^'•,..r._ �.�""pp :.{ ". ^• "f W�1•„t�.�.M.+tiv _..�"'I•yw_ �___ _ —I-._i'n^'-••.? r �1 +.+.�.�.+••ra++...r..ws.•r.+w�...r �' —wrr..wr..+.....r.�n 1 f� ANCHOR LN , APPA0 ED AS NOTED DATE• B.P.# N 640 05' 1011 N 130.0' FEE t Bv: COMPLY WITH ALL CODES DF NOTIFYBUILDING DEPARTMENT AT NEW YORK STATE& TOWN C DE' 631-765-1802 8AM TO 4PM FOR THE AS REQUIRED AND CO DITTO 'S OF FOLLOWING INSPECTIONS: SOUTHOLD Olydh'ZEp BUR P\ 5 D N C 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE SOUTHO! TOE"; �n. 2. ROUGH-FRAMING &PLUMBING SO I LLD TO6ti'Pd TRi `t 3. INSULATION so .DEC 4. FINAL-CONSTRUCTION MUST 'D ANN 'D I BE COMPLETE E%N.Y ,JTHOLD HPC 78 N so 0 y ALL CONSS RUCTION7 SHALLL MEET THECH,D REQUIREMENTS OF THE CODES OF NEW u' YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS 5 C)CCUPANCY OR : 7q BL . : 4 L10USE IS UNLAWFUL WITHOUT CERTIFICC,, EGRESS OF OCCUPANCY KNDON a.33r a N 23.�r � 11 27.50' ��. � 1583r.- ' ELECTRIC(��� r- - 12.00' INSPECTIONREQUIRED PROPOSED PARS AL k? x �i �� I Fq Y,' /� / MI t' GARAGE CONVERSUN 35.01 / �.,i ., PROPOSED FNSHED o� NCELLAR PLUMBING / X, AL PLUMBING WA§TE Er 28.021 T fiIPJG BEFORE COVERING-: EGRESS \ F`vU,fMR CERTIFICATION NNDON ON LEAD CONTENT BEFOR ON OF OCCUPAM Y z SOLDER USED IN WATER Iv SUPPLY S� r ' _ "rr^/07 EXCEED 2110 Or' 1/'o LOAD. 0 �-► s co sa � c o Additional Certification May Be Required. 1 1V O O �'-5 640 05' 10" E 63.241 SLOT PLAN ----- -- - -- --- -- 5CALE:1" = 20' SECTION: 7cl THIS IS AN ARCHITECTURAL SITE PLAN BASED ON INFORMATION SHOWN ON A !LOCK: 4 SURVEY PERFORMED BY RODERICK VAN TUYL DATED: 2-16-gn LOT: 10 AREA: -.25,057.07 5F ZONE: R40 ENERGY NOTE: TO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGEMENT, THESE PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH CHAPTER II OF THE 2020 NEW YORK STATE RESIDENTIAL CODE (2020 NYSRC) AND R103.2 OF THE INTERNATIONAL ENERGY CONSERVATION CODE RED '510NS TO PRELIMINARY DRAWINGS: RE�/ISIONS TO FINAL DRAWINGS: MUNICIPALITY AMENDMENTS: SHEET TITLE ,ED ARC GONSTRUcGTION DOCUMENTS 11 # DATE: BY: ## DATE: BY: # DATE: BY: "(% ?,r �a Ilu PROJECT NAME ° 2 2 2 � ,� �, K R R 51D�NGE 5 5 JE d -1,50 WINDJAMMER DR.-SOUTHOLD,N'(-Ilgll 4 4� 4 � . OYST�fi� BA)" DRAFTI1�C� SHEET NO. 5 5 da AND ARCHITECTURE,, P.C. DATE: 2-14-25 SCALE: A5 NOTED OF d 65 WEST MAIN STREET OYSTER BY SA , N.Y. 117-7 I r-7 _n (516) c122-5a-T& (FAX) 122—&255 WEB: NINKOYSTERBAYDRAFTING.COM EMAIL: ARCHITECT®O"YSTERBAYDRAFTING.COM JOB NO: 25OI5 27'-6" II'-4" 23'-4" NEW I-HR FIRE RATED °min THICKNESS TYPE"X" GWB MATERIAL ON THE WALLS t CEILING THROUGHOUT THE MECHANICAL ROOM; ALLOW NO OPENINGS A 271-611 WHERE WALLS ADJOIN 2 S o THE FDN. nTEGE55 Additional (2)2XI2„ Certification GAPS B/N NEW WALL B May Be required. t PC WALL HAVE TO EXIST. GAPS B/N NEW (WALL ,\�/ a BE SEALED WITH N C `�' PC WALL HAVE TO \ \ ' FFIRE OAM ;:I- SPRAY _COI-411 pC 5LXABCON GRADE LD 14'-4" o BE SEALED WIT4H �U`' � � o NMEWc k M 6X10 EXIST. BEAM W/CO�U N COVER FOAM FIRE PROOF SPLAY I I ECN. ROOM I - - --®—C -E - �� Co 1) LAYER 5/3" GH3 TYPE-X ON - ' N WALLS AND CEI ING OF GAR GE 6GFI REF. S.S. m I _ - (2)2 12� NEW SLEEPE @ 16� 0. . BAR ARE W 5-5 NEW 3' 112 N _ _ i Ni I RP ppeSD FINISHED CELLAR OFFICE w w r�cno o = (7'-8" CLG. HGT.) Iz zl REC ROOM — ®SD o U (7'-8" CLG. HGT.) NEW ZS %" FIRE RATTED MD 5-10 UP o N NEW LINE OF NEW A �� ROOM � 5HEETROCK ,� I I Z5 2 R `= MUD RM. ( �STEPS ABOVE - � I m 2 2 - j 4'-I" 2'-10" L I NEW S S@ 16" O C NEW 3 1/2"STEEL LALLY COLUMN , Ell OVER EX. PC. SLAB r—NEW 3 y LUMNS TO W/COLUMN COVER N COLUMN BE REMOVED TO BEAR ON 24"X24"XI2"DEEP PC EXIST. COLUMN — NCH TO ALIGN F.F.W/EX.NOUSE FNDN.TO BEAR ON UNDISTURBED SOIL N CL. W IOX54 NEW BEAM Q EXI5T. Q ' 2 EW GARAGE N EX15T. 23'-011 -3" M ATH %" FIRE RATED UNEXCAVA�TED - )150 CFM O a Q PC. SLAB ON GRADE SNEETROCK Z o 2-6° [NEW 2x4 WD STUDS @ 16' OC W/ 1/2" GWB ON 2, 2 Q EXPOSED 51DE W/ R-15 I:j C L. BATT INSULATION B/N N `` JOISTS; TYP. :.:....:...........: : - 1 NEW i NEW , 1 .IN CL.1 GYM (7'4' CLG. HGT.) EXI5T. EXIST. - I o I x LL `p 20 4 N - N I 6 oil 1— Iq'-7" _ (2)2XI2" C VERIF. J REPLACE EXIST.WIND. A 2 28'-41I 28'-4" 2114" 28'-0" 78'-0" (::)MA�ZTIA�LFIRSTFLODR PLAN - 5CALE:1/4" = 1'-0" C�L(�4R/�O�.NI�ATIDN CLAN SCALE:I/4" = I'-0" RE\/ISIONS TO PRELIMINARY DRAWINGS: RE\/ISIONS TO FINAL DRAWINGS: MUNICIPALITY AMENDMENTS: sCIAF� SHEET TITLE CONSTRUCTION DOCUMENTS # DATE: BY: DATE: BY: # DATE: BY: . ,��� �• � °.�` �° PROJECT NAME BURKE: RESIDENGE 2 2 2 150 WINDJAMMER: DR.-SOUTHOLD,V-IIg71 3 3 ". d • • 0 I STER L.3l't I DRAFTING SHEET NO. 4 4 4 5 5 ,� 1 C4 AND ARCHITECTURE, F.C. DATE: 2-14-25 Q➢ � & ,raj rld :, ., :..~..; o N.Y. 11771 SCALE: AS NOTED ZI 6 6 6 � OF A `�I� jj,� off° 68 WE(516 C122 5a-76 MAIN T (FAX) c122--6.255 aY: M.M. n}�� WEB: NM.OYSTERBAYDRAFTING.COM EMAIL: ARCHITECT@OYS'TERBAYDRAFTING.GOM IJOB NO: 25015 QU ` ^ HINDON HELL COVERS 180 NINDJAWER DR.-SOUTHOLD,N"(-I III I CLIMATIC 4 GEOGRAPHIC DESIGN CRITERIA iXxV, FOUNDATION WALL SUBJECT TO DAMAGE FROM WIND DE51GH " GROUND SEISMIC WINTER ICE BARRIER FLOOD AIR FREEZING MEAN 1 AIR SPACE SNOW LOAD ESIGN WEATHERING FROST LINE DESIGN UNDERLAYMENT HAZARDS INDEX ANNUAL SPEED MPH TOPGRAPNICAL SPECIAL WIND WIN - �' / VAPOR BARRIER CATEGORY THER G DEPTH TERMITE TEMP REQUIRED TEMP (MPH) EFFECTS REGION DEBRIS 2 X WD STUDS @ 161 O.C. 30 1bs/ t B SEVERE 3' pro S FEMA W/ R-15 BATT INSULATION HEAVY YE NFIP < 1500 45'F 125 mph YES NO I Mi. C.M.H.W.L. II EXIST. I/ 2" GYP. BOARD ISt.FL00R EXTERIOR NALL SCALE: N.T.S. EX.2 X 10 F.J @ 16 O.C. " " o EX.2 X 10" F.J @ 1611 O.C. GRADE � 7/8" _ ARTIFICIAL LIGHT CALCULATIONS ARTIFICIAL VENT CALCULATIONS P�XIO EXIST. BEAM - " COMBINED OPEN COMBINED OPEN �_EX15T.BEAM W IOX54 NEW BEAM NEW NEW 2x4 WD STUDS 16 LOCATION.......................... ....................... LOCATION.......................... ....................... II II SPACES SPACES Or W/ 1/2" GWB ON X 2 X DBL. TOP PLATE AREA (SF)........................ 1,220.18 5F AREA (5F)........................ 1,220.18 SF FINISHED CELLAR EXPOSED SIDE W/ R-15 LIGHT REQUIRED (8%)....... 97.614 5F ........ 8.00% VENT REQUIRED (4%)........ 48.807 5F ...................... 4.00% NEW I Y m OFFICE BATT INSULATION B/N 2"X 4" WD STUDS @ 16" O.C. JOISTS; TYP. II ROOM ARTIFICIAL ILLUMINATION COMPLIANCE REQUIREMENTS ARTIFICIAL VENTILATION COMPLIANCE REQUIREMENTS EX. PC. FNDN: - W/ 1/2 GWB ON EACH SIDE COMPLY W/SECTION R303.1.1 LIGHT, VENTILATION AND HEATING OF THE COMPLY WITH SECTION R303.1.1 LIGHT, VENTILATION AND HEATING OF RESIDENTIAL CODE OF NYS: DUE TO THE SQUARE FOOTAGE OF THE RESIDENTIAL CODE OF NY5: DUE TO THE SQUARE FOOTAGE OF NEW 'GLAZED AREA" NOT COMPLYING WITH SECTION R303 OF THE NEW YORK 'OPERABLE GLAZED AREA, NOT COMPLYING WITH SECTION R303 OF THE FLOORING F.F. STATE RESIDENTIAL CODE NEW YORK STATE RESIDENTIAL CODE, IT 15 NOTED THAT THE EXISTING (STIYLE AS PER OWNER) ACO 211X 4" SOLE PLATE A MINIMUM OF 6 FOOTCANDLES 30' ABOVE THE FINISHED FLOOR. DWELLING HA5 EXISTING CENTRAL WAC/MECHANICAL VENTILATION SYSTEM CAPABLE OF SUPPLYING VENTILATION I Y G OUTDOOR VENT LAT AIR OF 15 FLOOR FINISHING LOCATION.......................... RECREATION AREA CUBIC FEET PER MINUTE(ch) (7.08 Us)PER OCCUPANT. NR FIRE-RESISTANT WALL DETAIL AREA .................... 1220.18000 5F 0 LOOCATION.......................... RECREATION AREA _. �` NUMBER OF FIXTURES....... 15 AREA (5F)........................1220.180000 SQUARE FEET C'�'�/>�� ����I O� �_� SCALE:3" _ I I-OIL PC SLAB FIXTURE WATTAGE............ 60 WATTS w PROVIIDE (2) LAYER WTI. LUMEN5 PER FIXTUP.E....... 840 LUMEN5 CEILING HEIGHT................. 7.66 LINEAR FEET - -- GWB MTE-X FOR TWO (2) MR ROOM VOLUME................. 9346.5788 CUBIC FEET EXA" THICK POURED - SCALE:1/4" = 1'-0" RATED) FIRE-RESISTANCE ON LUMENS REOUIRED 7321.OS00 LUMENS 00 CONCRETE SLAB WALL5i, STAIR STRINGERS 4 (AREA)X(6 FOOTCANDLE5) REQUIRED AIR CHANGES PER HOUR.... ...... 3271.302580 CF CEILIWG OF ENTIRE CELLAR nl NT. PARTITION WALL DETAIL LUMENS PROVIDED 12600.0000 LUMENS (VOLUME OF ROOM) X 0.35 CHANGES PER HOUR STAIR ENTRANCE SCALE: I p /� I/�I I '/�I SCALE: N.T.S. (FIXTURES) X(LUMENS PER FIXTURE) REQUIRED AIR CHANGES PER MINUTE. ...... 54,521710 CF GE I`lE I AL !' `�I I�1PO '� NOTEs• CF AIR CHANGES PER HOUR / 60 MINUTES PROPOSED REQUIRED 12600 LUMENS > 7321.0800 LUMENS - ALL WINDOWS TO BE ANDERSEN OR APPPROVED EQUAL, MINIMUM DP RATINGS AS PER oD REQUIRED VENTILATION FOR SPACE.... ,•,••, 54.521710 CF DF-51GN CRITERIA TABLE LOCATED ON I7E5IGN STANDARDS SHEET. GENERAL CONTRACTOR NOTES: OK ARTIFICIAL LIGHT COMPLIES PROVIDE ONE (I)50 CFM FAN FOR ARTIFICIAL VENT COMPLIANCE -OR GENERAL ELECTRICAL NOTE5: GENERAL FLUMB I NG NOTES: PROVIDE SPECS FOR CENTRAL AIR FOR COMPLIANCY - ALL PROPOSED WINDOWS TO BE ANDERSEN "400" SERIES, MIN IS" FROM FINISHED - VERIFY ALL PITCH ANGLES PRIOR COMMENCEMENT OF WORK, ANY FLOOR TO TOP OF SILL/ BOTTOM EDGE U.O.N. - WIRING METHODS SHALL BE IN ACCORDANCE WITH SECTION DISGREPANGY WITH ANGLES, CONTRACTOR MUST PROVIDE THE CORRECT - SHOWERS AND SHOWER/TUB COMBINATIONS ANGLE IN ORDER TO MATCH ELEVATIONS. VERIFY ALL FIELD CONDITIONS E3801 OF THE :2020 NYS RESIDENTIAL GODS. ALLOWABLE SHALL BE EQUIPPED WITH CONTROL VALVES OF GENERAL L I G�TI NG NOTES: - ALL UPLIFT CONNECTORS t NAILING 51HALL BE IN ACCORDANCE W/ THE5E R PLANS, ALL APPLICATIONS FOR, WIRING METHODS SHALL BE IN LOAD PATHS SHALL BE AT EVERY EXTI=RIOR ALL STUD FROM FOUNDATION TO RIDGE. PRIOR TO CONSTRUCTION. ACCORDANCE !WITH TABLE E5501.4 OF THE 2020 NY5 THE PRESSURE COMBINE, THE THERMOSTATIC C�ENER, L BATH NOTE: W RESIDENTIAL GEODE GENERAL INSTALLATION AND SUPPORT MIXING OR THE COMBINATION PRESSURE - ALL CONNECTION DETAILS DESIGNED FOR W .WORST CASE SCENARIO; BALANCE/THERMO5TATIC MIXING VALVE TYPES CONTRACTOR TO COORDINATE ALL LIGHTING REQUIREMENTS - ALL NEW/PROPOSED EXTERIOR WINDOIW5 AND GLASS DOORS DESIGNED TO RESIST REQUIREMENTS FOR WIRING METHODS SHALL BE IN - CAP/RE-ROUTE PLUMBING LINES AS WIND LOADS SPECIFIED IN 2020 NY5 R.E51DENTIAL FIGURES R301.2(5)A 4 R301.2(5)B CONTRACTOR SHALL ALERT ARCHITECT IF SUBSTITUTIONS ARE INTENDED ACCORDANCE (WITH TABLE E5502.1 OF THE 2020 NY5 WITH HIGH LIMIT STOPS WITH OWNER. PROVIDE ARTIFICIAL ILLUMINATION SOURCES REQ'D FOR NEW FIXTURES/ FIXTURE AND ADJUSTED FOR HEIGHT AND EXPOSURE AS PER TABLE R301.2.1.3. ALL UNITS (ALL CHANGES MUST MEET THE 2015 WFCM MANUAL RESIDENTIAL G.ODE (MIN. AVG. ILLUMINATION: 6FC) WITH WALL SWITCHES IN ALL LOCATIONS AS SHOWN. TESTED AND APPROVED BY INDEPENDENT LABORATORY AND HAVE LABELS POSTED - ALL POTABLE WATER OPENINGS AND OUTLETS HALLWAYS, BATHROOMS, WALK-IN CLOSETS, 4 CELLAR FOR REVIEW IDENTIFYINS THE MANUFAC- URER, PERFORMANCE CHARACTERISTICS AND - ALL MICORLAM'5 (ML) ARE B015E VERSA-LAM 2,500 P51 4 L75" WIDTH - EACH NEW APPLIANCE FOR KITCHEN 4 LAUNDRY AREAS SHALL BE PROTECTED BY AN AIR GAP, SPACES. REFER TO "ELECTRICAL NOTES" SECTION ON SHEET - PROVIDE GFI OUTLET(5) IN APPROVED INSPECTION AGENCY TO INDICATE COMPLIANCE WITH REQUIREMENTS OF (UNLE55 NOTED OTHERWISE) SHALL HAVE Ai DEDICATED CIRCUIT, MIN 20 AMP CAPACITY ATMOSPHERIC TYPE VACUUM BREAKER, PRESSURE N-I FOR ADDITIONAL ELECTRICAL REQUIREMENTS LOCATIONS AS SHOWN (TO BE TYPE VACUUM OR HOSE CONNECTION BACK FLOW AAMA/NWWDA 101/I/5/2 - CONTRACTOR TO FIELD VERIFY EXISTING LOAD-BEARING/ STRUCTURAL (VOLTAGE AS PER MFR'S REQUIREMENT'S AS PER SECTION. PREVENTOR -ALL ELECTRICAL WORK SHALL BE CONFINED TO THE SPACE VERIFIED BY OWNER). COORDINATE ALL SMALL AFFFLIANCE RECEPTACLES IN KITCHEN CEILING RECESSED LIGHTING, WALL CONDITIONS/ JOIST DIRECTIONS UPON START OF "LIGHT" WORK (REMOVAL - ALL OPERABLE WINDOWS HONING SILLS LESS THAN 24 ABOVE THE FINISHED FLOOR LOCATIONS SHAALL BE WIRED TO A MINIMUM OF TWO (2) AND LOCATION ALLOWED FOR IT AND SHALL BE IN STRICT MOUNTED VANITY LIGHTING 4 CEILING OF WALL FINISHES/ 5UB5TRATE5); ALERT ARCHITECT OF ANY - SEPARATE SHUTOFF VALVES WILL BE PROVIDED CONFORMANCE TO THE NATIONAL ELECTRICAL CODE, AND GREATER THAN 72 ABOVE THE FIIWISHED GRADE OR OTHER SURFACE BELOW ON DEDICATED 2a AMP CIRCUITS A5 PER E3a01.3 OF THE 2020 EXHAUST VENT REQUIREMENTS W/ THE BUILDING'5 EXTERIOR SHALL BE FITTED WITH "FALL PREVENTION DEVICES" (HAVING DISCREPANCIES BETWEEN APPROVED PLANS $ EXIST. CONDITIONS NYS RESIDENTIoAL CODE. FOR EACH BATHROOM AND KITCHEN GOVERNING MUNICIPALITY AND NFPA 72. OWNER (ALL FIXTURES SHALL BE U.L. OPENINC75 THAT DO NOT ALLOW A 4" IMMEDIATELY DIjAMETER SPHERE TO PASS THROUGH THE LISTED 4 SUITABLE FOR BATHROOM OPENINGS WHERE THE OPENING IS IN ITS LARGEST OPEN POSITION) THAT COMPLY WITH - PROVIDE AR«,-FAULT CIRCUIT-INTERUPTER PROTECTION FOR - DRAIN, WASTE AND VENT PIPING AND FITTING - CONTRACTOR SHALL INSTALL, AS PER OWNERS DIRECTION, - PROVIDE VALLEY FLASHING a ALL VALLEYS; PROVIDE STEPPED MATERIALS SHALL COMPLY WITH TABLE P3002.1(1) ALL WIRING FOR NEW 5WITGHE5, FIXTURES, AND RE-CIRCUITING LOCATIONS). A5TM F 20c10 AS PER SECTION R512.2 OF THE 2020 NY5 RESIDENTIAL CODE. ALL NEW CIRGU)IT5 AS PER SECTION E3�102 OF THE 2020 NYS NEGE55ARY TO ALLOW FOR ALL NEW WORK, ALL REWIRING OF FLASHING � ALL WALL/ SLOPE ROOF INTERSECTIONS; GOR-A-VENT TABLE P3002.1(2) � TABLE P3002.3 OF THE 2020 RESIDENTIAL CODE. EXISTING FIXTURES AND LABELING OF GIRGUIT BREAKERS TO - PROVIDE CEMENTITUOU5 FMASHIIG AS REQ'd NYS RESIDENTIAL GORE. - ALL EXTERIOR WALLS ARE CONSTRUCTED AS TYPE I SHEAR WALL5 (1/2" PLYWD "WONDERBOARD" TILE BACKERBOARD W/ SD COMMON NAILS @)6 OG EDGE 4 12 OG FIELD AS SPECIFIED IN INDICATE CIRCUIT USE; FURNISH NFBU CERTIFICATE AT SHEATHING, - PROVIDE MINI. ONE (I) WALL SWITCH CONTROLLED LIGHTING OR I/2" "GREENBOAR.D" GWB; - ALL FASTENERS/ CONNECTORS USED IN CONNECTION W/ AGQ WD. SHALL - THE ENTIRE PLUMBING SYSTEM SHALL BE COMPLETION OF WORK. SECTION 5.4.4.2. IN THE AMERICAN FOREST $ PAPER ASSOCIATION WOOD FRAME OUTLET IN EAOfH HABITABLE ROOM, ALL EGRESS EXTERIOR TESTED IN ACCORDANCE WITH P2503 OF THE 2020 CONTINGENT UPON OWNER FINAL FINISH BE SIMPSON "ZMAX" RATED CON5TRUCTION MANUAL, THEREFORE ALL CONTINUOUS EXTERIOR WALL5 SHALL BE LOCATIONS, GARAGE DOOR LOCATION 4 AS ADDITIONALLY R W/ NY5 RESIDENTIAL GORE. - CONTRACTOR SHALL VERIFY WITH THE OWNER, LOCATION REQUIREMENTS, COOD. OWNER. CONSIDERED SHEAR WALL5 4 ARE IN EXCESS OF THAT REQUIRED BY THE CODE. ALL NOTED PER SECCTION E4001 OF THE 2020 NYS RESIDENTIAL REQUIRED SHEAR WALL SEGMENTS SHALL BE A MINIMUM OF 25" WIDE FOR 5'-0" HIGH - CONTRACTOR TO COORDINATE FINAL LEADER/ GUTTER REQUIREMENTS 4 CODE. AND QUANTITY OF LIGHTING FIXTURES AND 5WITGHE5 PRIOR TO „ „ - ALL HEATING, VENTILATING AND AIR CONDITION PROVIDING BID ON PROJECT. - ALL NEW FINISHES, SURFACES, WALLS, 31 FOR Q-O HIGH, 35 FOR 10-�O HIGH, � 38 FOR II-O LOCATIONS HIGH EXTERIOR WALLS OGGE55ORIES4 REQ'TS TO BE AS PER THE REQUIRED ASPECT RATION OF 5HEARWALL SEGMENTS. - ELECTRICIAN SHALL CONFIRM THAT AT LEAST ONE 5Y5TEM5 AND WORK MUST BE INSTALLED IN ACCORDANCE WITH CHAPTERS 13-24 OF THE 2015 - CONTRACTOR MUST VERIFY WITH HIS MIGENSED ELECTRICIAN COORDINATED BETWEEN CONTRACTOR - CONTINUOUS GUTTERS 4 LEADER SYSTEM W/ SPLASH BLOCKS TO BE THERMOSTAT IS PROVIDED FOR EACH SEPARATE HEATING t 4 OWNER. - AS PER 2020 NYS RESIDENTIAL GODS, SECTION R308: COORDINATED BETWEEN CONTRACTOR 4 OWNER COOLING SYSTIEM AS PER THE REQUIREMENTS NOTED FOR I.R.G. AND PER ALL LOCAL RULES, REGULATIONS IF AN UPGRADE OF ELECTRICAL SERVICE 15 REQUIRED FOR AND SPECIFICATIONS PER THE LATEST EDITION OF TH15 PROJECT PRIOR TO SUBMITTING A BID. ALL GLAZING INSTALLED IN HAZARD LOCATIONS (PAGING "WET SURFACES"; IN COMPLIANCE WyITH SECTION NI103.1 OF THE 2020 NYS - ALL BATHROOM CEILING EXHAUST GUARDS � RAILS; ADJACENT TO STAIR/ RAMPS; - PROVIDE CONTINUOUS RIDGE VENTS FOR ALL NEW ROOF RIDGES RESIDENTIAL CODE. THE NATIONAL FIRE CODE. VENTS 6 KITCHEN RANGE HOOD TO BE - CONTRACTOR TO VERIFY LOCATIONS OF MASTS, METERS, ADJACENT TO THE BOTTOM STAIR LANIDING; FRONT DOOR SIDELIGHTS) SHALL BE - PROVIDE ICE WATER SHIELD FROM FASCIA 8 WITHIN 2' HORIZ. 5UB-PANELS, ETC. FOR RELOCATION AS REQUIRED FOR THE VENTED THRU TO EXTERIOR WALL W/ 4" PROVIDED WITH MANUFACTURER'S OR INSSTALLER'5 LABEL, DESIGNATING THE TYPE - CONTRACTOR TO COORDINATE ALL LIGHTING - ALL MECHANICAL SYSTEMS. EQUIPMENT, APPLIANCES ETC MUST BE LISTED AND LABELED PROJECT. CONTRACTOR MUST ALSO NOTIFY THE ARCHITECT PIA. GALVANIZED DUCTWORK (OR THICKNESS OF GLASS 4 THE SAFETY GLAZINGDISTANCE FROM THE INTERIOR SIDE OF THE EXT. WALL; TYP. FOR ALL NEW STANDARD WITH WHICH IT COMPLIES, REQUIREMENTS WITH OWNER. PROVIDE ARTIFICIAL OF LOCATIONS IF NOT 5HOWN ON PLANS, PRIOR TO 51ZED AS OTHERWISE SPECIFIED IN WHICH IS VISIBLE IN THE FINAL INSTALLATION. LABELS SHALL BE ACID ETCHED, ROOFS, ALL TO COMPLY WITH SECTION Rc105.1.2 OF THE 2020 NYS ILLUMINATION 5oOURGES (MIN. AVG. ILLUMINATION: 6FC) WITH AND INSTALLED AS PER THE M SPECIFICATIONS, LISTING/LABELL AND TND THEE CODE COMMENCEMENT OF WORK 4 BIDDING MANUFACTURER'S SPECIFICATIONS), RESIDENTIAL GODS. SANDBLASTED, CERAMIC-FIRED, EMBO55ED MARK, OR SHALL BE OF A TYPE WHICH WALL SWITCHES IN ALL HALLWAYS, BATHROOMS, WALK-IN PER M1505 OF THE 2020 NY5 RESIDENTIAL CODE. ALL JOINTS 5EALED/WRAPPED W/ FOIL ONCE APPLIED CANNOT BE REMOVED WIITHOUT BEING DESTROYED. NO AFFIDAVIT CLOSETS, 4 GEILLAR SPACES. REFER TO "ELECTRICAL NOTES" TAPE. PROVIDE 4" DUCT HOOD W/ LETTERS WILL BE ACCEPTED. - ALL LOAD PATHS FROM FOUNDATION TO ROOF ARE CONTINUOUS 4 AT SECTION ON 5H'fEET - THE MAXIMUM WATER CONSUMPTION FLOW RATES DAMPER; SECURE TO DUCT WORK W/ EVERY WALL STUD N-I FOR ADDITIONAL ELECTRICAL REQUIREMENTS AND QUANTITIES FOR ALL PLUMBING FIXTURES AND SMOKE ALARM 4 CARBON MONOXIDE SEALANT 4 AS PER MFR'S ALL GLAZING INSTALLED IN HAZARDOUS LOCATIONS (MASTER BATH SHOWER; FRONT FIXTURE FITTINGS SHALL BE IN ACCORDANCE WITH ALARM NOTES: SPECIFICATIONS. DOOR SIDELIGHTS) SHALL BE PROVIDED WITH MANUFAGTURER'5 OR INSTALLER'S - FIELD GUT ENDS, NOTCHES $ DRILL HOLES THROUGH - ALL ELEGTRICGAL WORK SHALL BE CONFINED TO THE SPACE LABEL, DESIGNATING THE TYPE 4 THICK1NE55 OF GLASS 4 THE SAFETY GLAZING PRESERVED-TREATED WOOD SHALL BE TREATED IN THE FIELD IN AND LOCATIONI ALLOWED FOR IT, AND SHALL BE IN STRICT TABLE P2701.1 OF THE 2020 NY5 RESIDENTIAL (PER SECTIONS R314 R315 OF THE 2020 ELECTRICAL GODS, GORE. - CONTRACTOR TO PROVIDE NEW STANDARD WITH WHICH IT COMPLIES, WHICH IS VISIBLE IN THE FINAL INSTALLATION. ACCORDANCE WITH AWPA UI (SCTN R 517.1); SEE SECTION R317 CONFORMANCE' TO THE NATIONAL OF THENY5 RESIDENTIAL CODE) GREENBOARD/ OR CEMENT BOARD LABELS SHALL BE ACID ETCHED, SANDBLASTED, CERAMIC-FIRED, EMBOSSED MARK,OR GOVERNING MUNICIPALITY AND NFPA 72. AROUND BATHTUB/ SHOWER WALL AS 2020 NYS RESIDENTIAL GORE re PROTECTION AGAINST DECAY - THE WATER SUPPLY FOR DISHWASHERS SHALL SHALL BE OF A TYPE WHICH ONCE APPLIED CANNOT BE REMOVED WITHOUT BEING BE PROTECTED BY AN AIR GAP OR INTEGRAL - SMOKE ALARMS AS SHOWN ON THESE PLANS SHALL PER R307.2 OF THE 2020 NY5 DESTROYED. NO AFFIDAVIT LETTERS WIILL BE ACCEPTED FOR HAZARDOUS GLAZING AS - CONTRACTOR SHALL INSTALL, AS PER OWNERS DIRECTION, BACK FLOW PREVENTOR AS PER SECTION P2a02 BE INTERWIRED/ INTERCONNECTED BETWEEN THE RESIDENTIAL CODE PER SECTION R505 OF THE 2020 NYS hRE51DENTIAL CODE. - OWNER SHALL COORDINATE THE USE OF A PROFESSIONALALL WIRING FOR NEW 5WITGHE5, FIXTURES, AND RE-GIRGUITING "TERMITE OF THE 2020 NY5 RESIDENTIAL CODE. BASEMENT, 15T FLOOR $ 2ND FLOOR IN SUCH A MANNER BAITING SYSTEM", PROPERLY LABELED 4 INSTALLED/ MAINTAINED NEGE55ARY TO ALLOW FOR ALL NEW WORK, ALL REWIRING THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE - ALL PROPOSED PLUMBING WORK ACCORDING TO SUCH LABELING; SEE R315 OF THE 2020 NY5 RESIDENTIAL OF EXISTING FLXTURE5 AND LABELING OF GIRGUIT BREAKERS - THE DISCHARGE OF CLOTHES WASHING ALL OF THE ALARMS IN THE INDIVDUAL UNIT. THE THE SHALL UPHOLD THE PROTECTION OF CODE re PROTECTION AGAINST SUBTERRANEAN TERMITES TO INDICATE GIRGUIT USE; FURNISH NFBU CERTIFICATE AT MACHINES SHALL BE THROUGH AN AIR BREAK AS ALARM SHALL BE CLEARLY AUDIBLE IN ALL THE POTABLE WATER SUPPLY AS PER I. - ALL WINDOWS TO BE ANDERSEN OR APPROVED EQUAL, MINIMUM DP RATINGS AS PER DESIGN CRITERIA TABLE LOCATED ON COMPLETION OIF WORK. PER P2715.1 OF THE 2020 NY5 RESIDENTIAL CODE. BEDROOMS OVER BACKGROUND N015E LEVELS W/ ALL P2a02.1 THROUGH 172102.6.1 OF THE DESIGN STANDARDS SHEET. INTERVENING DOORS CLOSED. ONE CENTRALIZED 2020 NY5 RESIDENTIAL CODE.; 2. - ALL EXTERIOR WALLS ARE CONSTRUCTED AS TYPE I SHEAR WALLS (112' PLYWD SHEATHING, W/ 8D COMMON NAILS Woc EDGE - CONTRACTOR SHALL VERIFY WITH THE OWNER, LOCATION ALARM HORN FOR ALL SMOKE DETECTORS 15 PROVIDE "BACKFLOW PREVENTOR" 4 12"oc FIELD AS SPECIFIED IN 5ECTIION 3.4.4.2. IN THE AMERICAN FOREST 4 PAPER ASSOCIATION WOOD FRAME CONSTRUCTION FOUNDATION REQUIREMENTS: AND QUANTITY OF LIGHTING FIXTURES AND 5WITGHE5 - PROVIDE N MANUAL, THEREFORE ALL CONTINUOUS EXTERIOR WALLS SHALL BE CONSIDERED SNEARWALLS t ARE IN EXCESS OF THAT AND SHOWER ASS PER RBENT ER SURFACES FOR TUB R307.2 OF THE 2020 NYS REQUIRED. WITH INTERMEDIATE ATMOSPHERIC RESIDENTIAL CODE. VENT. REQUIRED BY THE CODE. ALL REQUIRED 5HEARWALL SEGMENTS SHALL BE A MINIMUM OF 28' WIDE FOR V-0" HIGH WALLS, 31' -ALL SPECIFIED P.G. FOUNDATIONS PRIOR TO PROIVIDING BID ON PROJECT. - CARBON MONOXIDE ALARMS AS SHOWN ON THESE FOR 9'-0" NIGH, 35' FOR 10'-0" HIGH, 4 38' FOR 11'-0" HIGH EXTERIOR WALLS AS PER THE REQUIRED ASPECT RATION OF COMPLY W/ 2015 I.R.G. CODE R404.1.1 - CONTRACTOR'. MUST VERIFY WITH HIS LICENSED PLANS SHALL BE INTERWIRED/ INTERCONNECTED PER FIGURE R307.1 OF THE 2020 NYS 5HEARWALL SEGMENTS. AND R405 ELECTRICIAN IF AN UPGRADE OF ELECTRICAL SERVICE 15 - SPACING BETWEEN BATHROOM FIXTURES TO COMPLY WITH FIGURE R307.1 OF THE 2020 NYS BETWEEN THE BASEMENT, IST FLOOR 4 2ND FLOOR IN RESIDENTIAL GORE, MIN 3. - ALL UPLIFT CONNECTORS 4 NAILING SHALL BE IN ACCORDANCE W/ DETAILS SHOWN, ALL LOAD PATHS SHALL BE AT EVERY REQUIRED FOR THIS PROJECT PRIOR TO SUBMITTING A BID. RESIDENTIAL CODE. SUCH A MANNER THAT THE ACTUATION OF ONE ALARM 24"CLEARANCE REQUIRED IN FRONT O EXTERIOR WALL STUD FROM FOUNDATION TO RIDGE. -ALL SPECIFIED P.G. FOOTING COMPLY WILL WILL ACTIVATE ALL OF THE ALARMS IN THE SHOWER OPENING 4. - ALL NEW FIREPLACES, UNLESS OTHERWISE NOTED, SHALL BE CONSTRUCTED IN FIELD AS PER CHAPTER 10 OF THE RCNY5. ALL W/ 2015 I.R.G. CODE R403.1 - CONTRACTORTO VERIFY LOCATIONS OF MASTS, METERS, NEW FIREPLACES ARE TO BE PROVIDED W/ ASN DUMPS 4 FRESH AIR INTAKES. INDIVDUAL UNIT. � MIN IS REQUIRED BETWEEN SUB-PANELS, ETfG. FOR RELOCATION AS REQUIRED FOR THE CENTER-LINE OF WATER CLOSET 5. - ALL SKYLIGHTS TO BE CONSTRCONSTRUCTEDW/ LAMINATED GLASS, NO RETAINING SCREEN REQUIRED, PROVIDE (3) ft VENT HOLES AROUND SKYLIGHT. - FOUNDATION WALL TO EXCEED 4" PROJECT. CONITRACTOR MUST AL50 NOTIFY THE ARCHITECT 6. - ALL WINDOWS 4 DOORS SHALL EITHER HAVE MANUALLY REMOVABLE STORM PANELS IN COMPLIANCE W/ ASTM E 1996 4 1886 AS ABOVE ADJACENT FINISHED GRADE AS OF LOCATIONS IF NOT SHOWN ON PLANS, PRIOR TO (TOILET) AND ADJ. WALLS OR OTHER MANDATED BY THE NEW YORK STATE RESIDENTIAL BUILDING CODE FOR IMPACT RESISTANCE IN IIOMPH WIND ZONES, CONTRACTOR PER R404.1.6 OF THE 2015 I.R.G. GOMMENGEMEN'T OF WORK BIDDING FIXTURES, F MIN IN FROM OF WATER ER CLEARANCE REQ'D CLOSET (TOILET). TO PROVIDE NECESSARY DOCUMENTATION ON COMPLIANCE TO THE BUILDING DEPARTMENT, FOR GARAGE DOORS PROVIDE ACCORDION DOORS W/ TRACKS INLA`(ED FLUSH INTO CONCRETE DRIVEWAY. -OR- 1/2"th PLYWOOD STRUCTURAL PANELS, SHALL BE PROVIDED FOR EACH WINDOW 4 DOOR OPENING NOT EXCEEDING 8'-0" (IN THE SHORTEST DIRECTION) THE PLYWOOD SHALL EXTEND A MIN OF 6" BEYOND THE ROUGH OPENING SIZES OF THE WINDOWS IN EACH DIRECTION 4 SHALL BE LABELED W/ THE REVISIONS TO PRELIMINARY DRAWINGS: REVISIONS TO FINAL DRAWINGS: MUNICIPALITY AMENDMENTS: A; , SHEET TITLE G0N5TRUGTI0N DOCUMENTS CORRESPONDING WINDOW LOCATION. THE PLYWOOD SHALL BE STACKED TOGETHER IN AN ACCESSIBLE LOCATION, 4 SHALL BE # DATE: E3Y: # DATE: E3Y: # DATE: BY: � c ' ' Ts R ACCOMPANIED BY ENOUGH 2-1/2" #8 WOOD SCREWS TO FASTEN EACH PANEL, SCREWS TO BE A MAXIMUM OF 12"oc AROUND I I O 1 Ind PROJECT NAME PERIPHERY OF PANELS. WHEN FASTENING TO MASONRY WALLS, VIBRATION-RESISTANT ANCHORS SHALL BE USED(MIN 4901bs BURKE RESIDENCE 2 2 2 780 WINDJAMMER DR.-50UTHOLDNY-IIg71 WITHDRAWAL CAPACITY). ALL OF THE AFOREMENTIONED HURRICANE PROTECTION SHALL BE THE SOLE RESPONSIBILITY OF THE 3 3 3 '# ;V '� �' HOME OWNER TO INSTALL, AS SPECIFIED, IN THE EVENT OF NIGH WINDS. � "�"`'"i ' ' X�`I'STER E3AY DRAFTING SHEET NO. 4 4 4 �'�� 7. - ALL RAILINGS 4 GUARD RAILS SHALL BE BETWEEN 36" 4 :38" IN HEIGHT, ALL HANDRAILS SHALL BE IN ACCORDANCE W/ R315.2, 4 5 5 5 �'u t- d ._A,n ,,:,, tda AND ARCHITECTURE �.�i. DATE: 2-14-25 a NO OPENINGS SHALL BE PRESENT IN SAID GUARDS THAT AILLOW THE PASSAGE OF A 4 0 SPHERE, UNLESS IT IS THE *'� I � d SCALE: AS NOTED TRIANGULAR OPENING FORMED BY THE RISER TREAD 4 BOTTOM RAIL - WHERE A SPHERE 6" IN m MAY NOT PASS THROUGH. 6 6 �e 68 WEST MAIN STREET OYSTER BAY, N.Y. 11771 of 7 ,� 7 � ` ova �' (516) q22-Sci76 (FAX) G22-6235 BY: M.M. o� WEB: WWW.OYSTERSAYDRAFTING.GOM EMAIL: ARGHITEGT@OY5TEPSAYDRAFTING.GOM JOB NO: 25015 Q� .. GENERAL CONDITIONS OF THE WORK: 5- ALL WORK LET UNDER THESE DRAWINGS SHALL BE GUARANTEED AGAINST DEFECTS IN MATERIAL AND WORKMANSHIP FOP, A PERIOD OF SITE WORK, GRADING AND*LANDSCAPING I- THESE NOTES SHALL APPLY TO THE GENERAL CONTRACTOR, EACH SUB-CONTRACTOR AND THE OWNER'S OWN FORCES. EACH CONTRACTOR ONE (I) YEAR FROM THE DATE OF THE ACCEPTANCE OF THE OWNER. GRANTING A CERTIFICATE OF OCCUPANCY, OR THE OWNER'S USE OF I- CONTRACTOR SHALL-:?FROM EFFECTED AREAS OF THE SITE AND REDISTRIBUTE ALL TOPSOIL UPON COMPLETION OF THE WORK, PROVIDING SHALL STUDY AND FAMILIARIZE HIMSELF WITH THE SITE AND WITH ALL TRADES AND ASPECTS OF THE WORK. EACH CONTRACTOR SHALL THE PREMISES SHALL NOT CONSTITUTE ACCEPTANCE OF THE WORK. FOR FINISHED,AM)INCf::AND RESEED NG OF THE LAWN AS DIRECTED BY THE OWNER. COOPERATE AND COORDINATE HIS WORK WIITH THE WORK OF OTHER CONTRACTORS AND TRADES. 6- THE CONTRACTOR SHALL ALSO DELIVER ALL MANUFACTURES' WARRANTIES, GUARANTEES, OPERATIONAL AND MAINTENANCE MANUALS 2- BACKFILL SHALL. N4tE..PLACEI?::A,AINST FOUNDATION WALLS UNTIL THE CONCRETE IS OF SUFFICIENT STRENGTH AND UNTIL THE WALLS 2- THE CONTRACTOR SHALL INSPECT THE 51TE AND MAKE ALL APPROPRIATE INQUIRES TO DETERMINE CONDITIONS AND FIELD CONSTRUCTION PERTAINING TO HI5 WORK. ARE PROF-ERLT. BI AICEDT*-.':AND BOTTOM BY THE HORIZONTAL FLOOR OR BY ADEQUATE TEMPORARY BRACING. CRITERIA PRIOR TO SUBMISSION OF BIDS, AND SHALL MAKE NO ,ADDITIONAL CLAIMS REGARDING SITE CONDITIONS THEREAFTER. THE 7- EACH CONTRACTOR SHALL ALSO DELIVER TO THE OWNER WRITTEN GUARANTEE IN FORM AND WHOSE TERMS AND EXTENT WILL BE 3--GRAIIff�4 Ak�OEJf}1[::.ALL NEW"CONSTRUCTION SHALL SLOPE AWAY FROM THE FOUNDATION WALL AND SHALL BLEND INTO EXISTING GRADES. CONTRACTOR'S AND OWNER'S AGREEMENT TO ENTER INTO THE WORK SHALL SUFFICE AS THEIR ACCEPTANCE TO THE TERMS SPECIFIED ESTABLISHED IN THE AGREEMENTS BETWEEN EACH CONTRACTOR AND THE OWNER. ;;:::.4- ALL SITE DE SfGfV::INCLUDING TOPOGRAPHY, STORM DRAINAGE SPECIAL PAVING, LANDSCAPING, ETC. SHALL BE PROVIDED BY OTHERS HEREIN AND SHALL BE INCORPORATED INTO ANY AND ALL AGREEMENTS BETWEEN THE OWNER AND THE CONTRACTOR. ARCHITECT'S SERVICES DURING CONSTRUCTION • �' :.:.:t1NLESS SPECIFIED HEREIN. 3- NOTHING ON THESE DRAWINGS SHALL BE CONSTRUED AS MODIFYING IN ANY WAY THE CONTRACT BETWEEN THE OWNER AND CONTRACTOR I- THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR THE PERFORMANCE OF THE GENERAL CONTRACTt2R'::QR ASY SUB-CONTRACTORS NQR::;•• -.-:75:CONTRACTOR SHIALL PROVIDE FOR ALL DRIVEWAY MODIFICATIONS AS REQUIRED ALLOWING FOR ACCESS TO AND FROM THE SITE. ALL NEW OR THE CONTRACTOR AND SUB CONTRACTORS. SHALL HE GUARANTEE THE PERFORMANCE OF THEIR CONTRACTS. THE OBLIGATION OF THE..C.O.NTRACTDR 5HALL%NOT EXTEND TO Tk�E. .. E-URBS, CURB; UT5 AND PAVING MUST COMPLY WITH ALL REQUIREMENTS FOR THE GOVERNING MUNICIPALITY t 2020 NY5RC.. 4- THE OWNER SHALL BE RESPONSIBLE FOR ANY ANOMALIES AND/OR IRREGULARITIES DISCOVERED DURING THE CONSTRUCTION PHASE OF THE """ "" .......' N ON N PART OF THE CONTRACTOR SUB-CONTRACTORS OR THE LIABILITY OF THE ARCHITECT, NIS AGENTS OR EMPLOYEES. DO(7C;:A�ND"WINDOW NOTES: PROJECT WHICH MAY REQUIRE ADDITIONAL MEASURES TO BE TAKE THE P R r 2- THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR NOR HAS CONTROL OR CHARGE.�F CONSTI-ft-'-TION lE'ffl'S..:SEQUENCES-:� R " ARCHITECT. ANY AND ALL CO5T5 RELATED TO THE ADDITIONAL WORK SHALL BE THE SOLE RESPONSIBILITY OF THE OWNER INCLUDING THE F I- ALE NEW WINDOIWS SHALL BE PERMA-SHIELD FINISH IN WHITE AS MANUFACTURED BY ANDERSON OR APPROVED EQUAL - FURNISHED WITH PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS. THE CONTRACTOR 5HA-'�..-3E RESPQN IBLE F(3J2�ADEQUATBt:�..BRACING'>N.D::::.. ,I ADDITIONAL SERVICES OF ANY OUTSIDE AGENCIES, INCLUDING BUT NOT LIMITED TO SURVEYING, PILES, EXTERMINATION BORINGS, .......... •• INSECT SCREENS, GRILLS, JAMB EXTENSIONS, TRIM ETC., WITH 5/8 INSULATED GLASS UNLESS OTHERWISE AGREED TO. PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, COLLAP5Er:::TASTORTIOAI:AND MISALIGNOENT ACCORDING Ta*::;`;:* :'..;;' 2- ALL EXTERIOR DOORS WITHOUT GLAZING SHALL HAVE PEEP HOLES INSTALLED.. UNDERPINNING, SITE DRAINAGE, ADDITIONAL CONSULTATIONS, 51TE VISITS, CERTIFICATION LETTERS, AMENDMENTS, AS BUILT DRAWINGS, ETC. APPLICABLE CODES. . 3- THE ARCHITECT HAS NOT BEEN RETAINED ON THI5 PROJECT FOR.1IDDING AND/OR THE..'KEGOTIATION AND ADMINl'?R.-ATf0N--.OF THE 3- ALL WINDOWS 4 DOORS WITH GLAZING 18" OR BELOW ABOVE FINISHED FLOOR (A.F.F.) SHALL BE ORDERED WITH TEMPERED GLASS. CONTRACTS FOR CONSTRUCTION OF THIS PROJECT. IF PROJECT LIE5i WITHIN A MILE OF THE COAST LINE, ALL WINDOWS t DOORS SHALL BE ORDERED WITH LAMINATED GLASS. EXISTING SITE CONDITIONS 4- CONTRACTOR TO) VERIFY ALL ALL OF THE ARCHITECT'S WINDOW t DOOR SPECIFICATIONS PRIOR TO ORDERING ANY WINDOW/DOORS. 4- THE ARCHITECT IS NOT RETAINED FOR 51TE INSPECTIONS;:AND/Of 'OBSERVATION OF THE CONSTRWTIQN. I- ALL EXISTING EQUIPMENT, UTILITIES STRUCTURES AND OTHER ITEMS INTERFERING WITH THE INSTALLATION OF THE PROPOSED EQUIPMENT 5- NO REQUEST FROM ANY PARTY FOR INFORMATION R'EGART3f1u:GLASSIFICATION AMPLIFICATION OR Ef'I RfiIATION OF THE.'T�AWINGS OR IF THERE ARE AINY DISCREPANCIES WITH SIZES, IT IS THE CONTRACTOR'5 RESPONSIBILITY TO CONSULT WITH ARCHITECT PRIOR TO AND STRUCTURES SHALL BE REMOVED AND REPLACED AND SHALL BE SUBJECT TO APPROVAL OF THE OWNER. NOTATION, OR REQUEST FOR PERMISSION TO VARY;..Q�2 DEVIATE"`f'f�Qfi�:.THE REQUIREMENTS OF THESE DRA;t�IN�S:.�OR••NOTATJONS, WILL BE COMMENCEMENT ,OF ANY WORK. 2- THE CONTRACTOR SHALL DETERMINE AND/OR VERIFY THE ACTUAL LOCATION OF ANY AND ALL UTILITIES, PIPING AND RELATED ITEMS ENTERTAINED BY THE ARCHITECT UNLESS THEY AR ''-SET FORTH IN'fnfl}TING AND ADDRESSED TO TNE:.O% WNER`. :I : C#E OWNER REFERS 5- CONTRACTOR SNIALL CONSULT WITH OWNER PRIOR TO ORDERING ANY WINDOW AND DOOR HARDWARE FOR OWNER SPECIFICATIONS. PRIOR TO THE COMMENCEMENT OF WORK. ALL COSTS INCURRED SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR UNLESS OTHERWISE THESE REQUESTS TO THE ARCHITECT, THE.A{�tAlTE=CT WILL WITH REASONABLE PRONPT4F.55 CONSIDER -THE MAT-TER AND RESPOND IN ROOFING: AGREED UPON BY THE OWNER. WRITING TO THE OWNER FOR TRANSMITTAL TO THIE*.:'.PARTY CONCERNED. THE AC�Af�JTECT-REPRE5. DOES':NQT NOR WILL ASSUME I- ALL METAL FLA5INING WHERE CALLED FOR ON PLANS SHALL BE COPPER OR ALUMINUM . 3- ALL DIMENSIONS AND LOCATIONS AS INDICATED ON THE DRAWINGS SHALL BE CONSIDERED CORRECT BUT SHALL BE UNDERSTOOD THAT ANY RESPONSIBILITY WITH REGARD TO THE ABOVE.-`-MENTIONED TYPES OF INQUfRY:':TJNLES'5"::A90YE PROCEDURE I5 FOLLOWED. 2- CONTRACTOR SNIALL PROVIDE GUTTERS AND LEADERS AS REQUIRED AND SHALL CONNECT THEM TO THE APPROVED STORM WATER THEY ARE SUBJECT TO MODIFICATIONS AS MAY BE NECESSARY OR DESIRABLE AT THE TIME OF INSTALLATION TO MEET UNFORESEEN OR ANY OTHER CONDITIONS. TEMPORARY PROTECTION AND'S�'( CTURES `. `�` •""' DRAINAGE SYSTEM I- THE CONTRACTOR SNAL ... .RESPON IBLE FOR TEMPORARY ELEC. RIC �hiAT7R. TOILET FENCING BARRICADES SECURITY AND 3- ALL SKYLIGHT OPENINGS SHALL BE PROPERLY FLASHED. 4- DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS SUPERSEDE SCALED DIMENSIONS AND ARE SUBJECT TO REVISIONS AS PER ACTUAL . ...�.. S.. T -::._:! , '••.. ' 4- ALL WORKSNA " BEAR A W I N N I FIELD CONDITIONS. THE CONTRACTOR SHALL VERIFY ALL DIMEN`.51ON5 AND CONDITIONS HEREIN SHOWN, AND ALL DISCREPANCIES ARE TO BE CLEAN UP AS AGREED. UPONt-*:E�P:F1IEER:-T--Nf::':PNNER AND THE CONTA�--TQR. UP.QN::;COMPLETfON OF WORK THE CONTRACTOR SHALL BROOM L� R R TTE ONE O YEAR GUARANTEE FROM ROOFING CONTRACTOR FROM THE DATE OF THE OWNER S BROUGHT TO THE ARCHITECT'S/REPRES. ATTENTION BEFORE COMMENCING WITH THE WORK. CLEAN ALL AFFEGTED-AREAS i�Nfl::::CART A-WAT.X'ALL DEBRIS. % ACCEPTANCE App1tIONAL MANUFACTURER WARRANTIES SHALL BE PROVIDED WHEN APPROPRIATE. 5- IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, THE 2- THE CONTRACTOR CONfR'T.,ALL WORK TO PRECLUDE THE EERR�TS OF:::WEATHER ON COMPLETED WORK, OR WORK IN PROGRESS. 5- ALL ROOF INTERSECTIONS TO HAVE FLASHING TO EXTEND 8" (MEASURED VERTICALLY) ABOVE FLAT ROOF. CONTRACTOR SHALL STOP ALL WORK AND NOTIFY THE ARCHITECT 50 AS TO ALLEVIATE SUCH CONFLICT WITHOUT BURDEN TO THE OWNER. THE CONTRA�T(O....SHAj�I:..ASSUME�'AP�::RE5PONSIB}LITY AND EXPENSE OF'�:.E -POPARY ENCLOSURES WHERE NECESSARY. DUST PARTITIONS 6- FOR ROOFS PITCHED 3:12 AND UP, NEW ROOFING SHALL BE ASPHALT SHINGLES(UNLE55 OTHERWISE NOTED) OVER 15# FELT , I LAYER OF .. "' ""' """' UNDERLAYMENT REQUIRED WHEN ROOF PITCH IS 4:12 AND ABOVE OTHERWISE TWO LAYERS SHALL BE USED FROM 3:12 UP TO 4:12 INSTALL SHOULD HE FAIL TO FOLLOW TNI5 PROCEDURE AND CONTINUE WITH THE WORK, HE SHALL ASSUME ALL RESPONSIBILITY AND LIABILITY ARE.:TD•:BE P0V.00 BETWEEN WORK AREAS AND THE REST OF THE BUILDING. "' "' "' ' ' ."" . AND LAP JOINTS AS PER 2020 NYSRC. AND MANUFACTURERS SPECIFICATIONS. PROVIDE AN ICE AND WATER SHIELD ARISING THERE FROM. 3.-. EAC4k:::':ONTRAC7�'5HALL;::Bf RE5PON51BLE FOR ALL LOSS OR DAMAGE ARISING FROM THE ACTION OF THE ELEMENTS SUCH AS WATER, UNDERLAYMENT WITIHIN 2'-0" 6- THE CONTRACTOR SHALL CHECK AND VERIFY LOCATION OF Mt Y EXISTING OVERHEAD OR UNDERGROUND ELECTRICAL OR OTHER HAZARDOUS.- : IE�T, WINf3 OR OTHER::IINFOPESEEN;.DfEEfCIJf lES THAT MAY BE ENCOUNTERED IN PERFORMING THE WORK TO BE DONE UNDER HIS CONTRACT. (PROJECTED HORIZONTALLY) FORM THE INTERIOR SIDES OF EXTERIOR WALLS BELOW, FOR ALL ROOF UTILITY LINES AND TO ARRANGE FOR THEIR SAFE RELOCATION. R-.%:H(E.EVENT OF ANY'�U5PEN510N�OF WORM ARIL•CONTRACTOR OR SUB-CONTRACTOR SHALL PROTECT NIS WORK AND MATERIALS AGAINST OVERHANGS. A5PHkLT SHINGLES TO BE ATTACHED WITH A MIN OF TWO 12GX3/4' LONG GALVANIZED ROOFING NAILS MIN TWO PER SINGLE 7- THE CONTRACTOR SHALL BE HELD TO HAVE VERIFIED DIMENSIONS AND CONDITIONS AT THE BUILDING, NO LATER CLAIMS WILL BE •..`:`.": :.;,. DAF9A�E•:.OR LOSS. ANY WORK OR MATERIALS TROT--.':HAVE BEEN DAMAGED/DESTROYED OR LOST BECAUSE OF FAILURE OF ANY CONTRACTOR OR SHINGLE AND SIX PER STRIP SHINGLE CONSIDERED FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED OR FOR DIFFICULTIES ENCOUNTERED BECAUSE OF LACK OF INFORMATION, LACK':..:::.SUB=G�T3T;ACTOR TO SO..PROTECT NI5 WORK OR MATERIALS SHALL BE PROMPTLY REMOVED AND REPLACED BY THE CONTRACTOR. 7- FOR ROOFS PIT-'AED BETWEEN 1:12 AND 3:121 NEW ROOFING SHALL BE ROLLED ROOFING WITH AN ICE AND WATER SHIELD UNDERLAYMENT OF SITE INSPECTIONS OR IMPROPER EVALUATION OF THE WORK (INVOLVED. ...,*. TNE'CFINTRACTOR SHALt.:GQNDUCT ALL WORK IN SUCH A MANNER 50 TO NOT IMPAIR THE STRUCTURAL INTEGRITY OR STABILITY OF WITHIN 2'-O" (PROJECTED HORIZONTALLY) FORM THE INTERIOR SIDES OF EXTERIOR WALLS BELOW FOR ALL ROOF OVERHANGS. ...... ...... 8- CONTRACTOR MUST VERIFY WITH HIS LICENSED ELECTRICIAN IF AN UPGRADE OF ELECTRICAL SERVICE 15 REQUIRED FOR THIS PROJECIT :DJACEI�T STRUCTURES E ftl r AIT1.,. OR UTILITIES. SHOULD DAMAGE OCCUR AS A RESULT OF THE WORK, THE CONTRACTOR SHALL REPAIR 8- FOR ROOFS BELOW 1:12 BUILT UP ROOFING SHALL BE 20 YEAR JOHNS MANVILLE ROOFING SYSTEM, CONSISTING OF I LAYER OF NRGII ISO, PRIOR TO SUBMITTING A BID. 3R REPLACE SAID DAMAGED ITEfvkS:TQ:CNE SATISFACTION OF THE OWNER, AND AT THE CONTRACTORS EXPENSE. THE CONTRACTOR SHALL I LAYER OF DYNABAISE SET IN MBRCAA AND I LAYER OF DYNAKAP SET IN MBRCAA. q- CONTRACTOR TO VERIFY LOCATIONS OF MASTS, METERS, 5UEB-PANELS, ETC. FOR RELOCATION AS REQUIRED FLU.:;-THE PkJECT. .••..;.. BEAR ANT`ANT7::ALL COSTS*:•ASSOCIAT:--f3 WITH WORK DISCONTINUATION ENGINEERING CONSULTATION, MATERIALS TESTING, REPAIR AND ALL q- NEW WORK SHALL TIE IN AND LAP SO AS TO PREVENT LEAKAGE ACCORDING TO ACCEPTABLE BUILDING PRACTICES ADDRESSED IN THE CONTRACTOR MUST AL50 NOTIFY THE ARCHITECT OF LOCATIONS IF NOT SHOWN ON PLANS. MISCE--d"'A OU""RELATED ITEMS, 2020 NYSRC. 5- TH'E:.:0-TRAC�fl12:;5HALL::>3RACE SHORE REINFORCE AND/OR UNDERPIN ALL STRUCTURES INCLUDING NEIGHBORING STRUCTURES AS 10- ALL EXTERIOR MAILING SHALL BE ALUMINUM OR GALVANIZED. CONTRACTOR'S RESPONSIBILITIES FOR COORDINATION AND WORKP�fANSNIP _ REQUIRED.:fOR 5AF€ &ERATION. 11- FLASHING TO BE PROVIDED AT ALL ROOF PENETRATIONS, PIPES VENTS, SKYLIGHTS CHIMNEYS AND ROOF VENTILATORS. FLASHING TO BE AN OTHER CONTRACTS SNA .. PROVIDE..... ' Y POSSIBLE 6- THE COt>J:TRACTOR:`T�5 TO TAKE ALL NECESSARY AND PRUDENT STEPS TO SNORE AND BRACE EXISTING STRUCTURES PRIOR TO PROVIDED AT HIPS RIDGES, VALLEYS CHANGES OF ROOF SLOPE, GABLE ENDS AND TOP OF FOUND. WALLS. I THE CONTRACTOR SHALL COORDINATE .SCHEDULING OF SUB-CONTRACTORSp ANC.. I PROVIDE-1-VERY IN5TALLATIOR`.:17.:HEADER5 FOR NEW OPENINGS. THE PROPER AND SAFE EXECUTION OF THIS WORK I5 THE SOLE RESPONSIBILITY OF THE 12- INSTALL SHIMS "TO PROVIDE ROOF PITCH UNDER SHEATHING AND PERPENDICULAR TO THE ROOF JOISTS TO PROVIDE FOR ROOF VENTING COOPERATIVE EFFORT TO COORDINATE COMPLETION OF ALL WORIK. THE GENERAL CONTRACTOR SHALL C LETE A COMPROEN51VE SCHEDULE FOR ALL WORK PERTAINING TO ALL CONTRACTS AND SHALL SUBMIT THE SAME TO THE OWNER`'-I:f"ACCEPTABLE FORMA-F-:fQR CONTRACTOR..... IN FLAT ROOF AREAS. REVIEW WELL IN ADVANCE OF WORK COMMENCEMENT. 7- EQUIPMENT AND DEVICES OF A TEMPORARY NATURE REQUIRED FOR THE CONSTRUCTION PROCESS AND PROTECTION THEREOF, SUCH AS 13- ALL INTERIOR :EEADERS ARE TO HAVE I/2" FOAM SOUND INSULATION OVER PVC PIPING. A COORDINATE CONSTRUCTION ACTIVITIES WITH THE OWNER TO MINIMIZE INTERRUP:GSONS TO NORI�r'.'.7. WN......:::::.. SCAFFOLDS STAGING, PLATFORMS, RUNWAYS, HOISTS, LADDERS, CHUTES, TEMPORARY FLOORING, GUARDS, RAILINGS, SHAFT WAY 14- CONTRACTOR 5HIALL PROVIDE GUTTERS AND LEADERS AS REQUIRED AND SHALL CONNECT THEM TO THE APPROVED STORM WATER 2- THE CONTRACTOR SHALL CO RD TE :.. PROTECTIONS ETC., FOR THE PROTECTION OF WORKMEN AND TO THE PUBLIC SHALL BE PROVIDED, ERECTED AND MAINTAINED IN DRAINAGE SYSTEM. OPERATIONS. -• 7. T .`"**"**ACCORDANCE WITH THE REQUIREMENTS OF ALL NEW YORK STATE CODES AND ALL OTHER LAWS RULES OR ORDINANCES OF ALL 3- EACH CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING, FITTING AND PATCHING OF NI5 WORK THAT MAY BE-REQUI�t�JED TO"OOhIPLETE•***'���� , , , FINISH WORK NOTES:: GOVERNMENTAL AGENCIES HAVING JURISDICTION DURING CONSTRUCTION. THE WORK OF HIS CONTRACT. NO CONTRACTOR SHALL ENDANGER ANY WORK OF ANY OTHER CONTRACTOR E3Y'.';_f#LAVAT�NG, CUTTIN+ '.;:QR; I- TRIM, MOLDINGS, CASINGS, WINDOW FRAMES, ETC. SHALL MATCH EXISTING UNLESS OTHERWISE NOTED ON DRAWINGS, PAINT OR STAIN AS OTHERWISE ALTERING ANY OF ANY OTHER CONTRACTORS WORK, AND NO CONTRACTOR SHALL DO 50 WIT QUT .PROR.WRTTEN••.CON5)NT'OF 8 THE CONTRACTOR SHALL PROVIDE, ERECT, MAINTAIN TH05E ITEMS REQUIRED FOR USE, OBTAINING ALL NECESSARY PERMITS, INSPECTIONS AND APPROVALS AND REMOVE THOSE ITEMS WHICH HAVE SERVED THEIR PURPOSE AND WHEN DIRECTED BY THE OWNER, UNLESS OTHERWISE PER OWNER. THE OWNER. ANY COSTS CAUSED BY DEFECTIVE OR ILL-TIMED WORK SHALL BE BORNE BY THE PARTY RtSPONS}E3�.E'THEREFQR_E. STIPULATED BY THE OWNER. 2- CONTRACTOR SHALL PROVIDE WOOD STEPS TO GRADE(UNLE55 OTHERWISE NOTED). NUMBER OF STEPS REQUIRED TO BE DETERMINED IN FIELD. 4- CONTRACTORS OR SUB-CONTRACTORS WHOSE WORK AND IN5TFALLATION5 REQUIRE SLEEVES, .HAI .-1?. INSERTS B(� T-1' - ANQNOR5 ETC., TO ALL DECK LUMBER TTO BE A.C.Q.(ARSENIC FREE PRESSURE TREATED LUMBER) BE BUILT INTO THE WORK OF OTHER CONTRACTORS SHALL INSTALL OR PROVIDE THESE ITEMS::TO Tkf:: PPROPRiATE°CONTRACTOR WHO WILL DEMOLITION NOTES: 3- ALL EXTERIOR WOOD FENCE AND DECKING MATERIALS TO BE WATER SEALED. SET THESE TO WORK IN THE LOCATIONS ESTABLISHED BY THE CONTRACTOR WHO REQUIRES THESE ITt 'T�:'::.THESE ITEMS SHALL BE I- THE CONTRACTOR SHALL ASCERTAIN THAT THE AREA OF DEMOLITION OAS BEEN CLEARED OF ALL FURNITURE AND MOVABLE EQUIPMENT IN 4- CONTRACTOR SHALL SEAL AND / OR PRIME ALL DOORS IMMEDIATELY UPON INSTALLATION TO AVOID WARPING. ......... PROVIDED ANp THEIR LOCATIONS COORDINATED SUFFICIENTLY IN ADVANCE, 50 AS NOT•TO•`DELAY THE PRQ`RES5 OF A JOB AS A WHOLE. ORDER TO ALLOW FOR DEMOLITION TO PROCEED. THE CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY OF ANY SUCH CONDITIONS 5- ALL GLAZING AND SKYLIGHTS SHALL BE IN ACCORDANCE WITH THE 2020 NYSRC. FOR IMPACT RESISTANCES. ALL SUCH ITEMS SHALL BE INCORPORATED SO THEY WILL MEET THE CORRECT PH'S' ICAL ELEVATIONS OF rl: f AT EACH LEVEL. THEY PREVENTING HIS PROCEEDING WITH THE DEMOLITION. SHALL BE SECURED INTO THE FRAMEWORK: FOR CONCRETE 50 AS TO MAINTAIN THi.'[R::.F'WP£k':"": ATION AND POSITION DURING THE PLACING 2- ALL ELECTRICAL HIGH OR LOW VOLTAGE CONDUITS, WIRES INSTRUMENTS AND EQUIPMENT ADJACENT TO OR CONTAINED WITHIN 6- ALL GYPSUM BOARD WALLS AND CEILINGS SHALL BE TAPED AND SANDED WITH A MIN OF 3 COATS OF SPACKLE PRIMED AND READY FOR OF CONCRETE AND REMOVAL OF FORMWORK. ....`...... PARTITIONS TO BE REMOVED BACK TO THE NEXT PANEL BOARD AND SHUTDOWN. NO CIRCUITS, WIRES OR EQUIPMENT SHALL REMAIN OPEN WALL FINISHING AS PER OWNER. 5- THE CONTRACTORS SHALL MAKE TIMELY SUBMISSIONS TO THE OWNER OF.-THE VARIQUS ITEMS:SET FORTH SO AS TO ALLOW REASONABLE OR LIVE. 7- THE OWNER SHALL SELECT ALL COLORS FOR APPLIANCES PAINT TILE, CABINETRY, EXTERIOR PAINTING COUNTER TOPS AND KITCHEN AND ADEQUATE TIME FOR REVIEW, POSSIBLE CORRECTION, PO55:1Et-f---:RESUBMISSION, AND-:FQR APPROVAL OF SUBMISSIONS WITHOUT DELAYING 3- DEMOLITION INCLUDES COMPLETE REMOVAL AND DISPOSAL OF ALL ITEMS FROM SITE, EXCEPT ITEMS DESIGNATED TO BE REMOVED AND CABINETRY. .. ......:....... .. THE PROGRESS OF THE ENTIRE PROJECT OR ANY PHASE OF THE: PROJE•� .';:`: RETURNED TO THE OWNER FOR RE-USE. MATERIALS OR. ITEMS SUCH AS DOORS AND FRAMES, GLASS AND LIGHTING FIXTURES DESIGNATED 8- CARPETING SHALL BE FURNISHED AND INSTALLED AT THE OWNERS EXPENSE UNLESS OTHERWISE AWARDED IN THE CONTRACT 6- ANY MATERIALS OR WORKMANSHIP FOUND AT THE TIME;;TO BE DEFECTIVh:'BNALL BE REMEDIED AT ONCE, REGARDLESS OF PREVIOUS ON DRAWINGS TO REMAIN THE PROPERTY OF THE OWNER SHALL BE REMOVED WITH CARE AND STORED IN A LOCATION ON THE SITE TO BE q- CONTRACTOR SHALL PATCH AND MATCH ALL FINISHES AFFECTED BY THE NEW CONSTRUCTION FOR BOTH THE INTERIOR AND EXTERIOR. INSPECTION. THE INSPECTION OF THE WORK IS INTENDS[) Y3:.'A1D THE CONTRACTOR IN APPLYING LABOR AND MATERIALS TO AND IN DESIGNATED BY THE OWNER. 10- UPON COMPLETION OF THE WORK, THE CONTRACTOR SHALL BROOM CLEAN ALL AFFECTED AREAS AND CART AWAY ALL DEBRIS. ACCORDANCE WITH THE SPECIFICATIONS, BUT SUCH.:fNSPECTI01Jf?'�I:TALL NOT OPERATE TO RELEASE THE CONTRACTOR FROM ANY OF NIS 4- CONTRACTOR SHALL OBTAIN ALL PERMITS FOR ALL WORK, INCLUDING PERMITS FOR TRANSPORTING AND DISPOSAL OF DEBRIS AND II- WATERPROOF AL IL BARROOM FLOOR.-.-AND PROVIDE COVE BASE AS PER 2020 NYSRC. ..::.. ...:. CONTRACTUAL OBLIGATIONS. OTHERS AS REQUIRED BY AUTHORITIES HAVING JURISDICTION INCLUDING ANY HAZARDOUS MATERIALS THAT MAY BE DISCOVERED. 12- ALL STAIR CON��TRUft-"N TO COnf'LY WITH 2O20 NYSRC.. . 7- ALL NEW MATERIALS AND INSTALLATIONS SOALL'-::E*.**.lN ACCO><RFfANCE WITH MFG. LATEST PRINTED SPECIFICATIONS AND WITH ALL 5- CONTRACTOR 15 REQUIRED TO NOTIFY OWNERS OF ANY AND ALL REQUIRED UTILITY SHUTDOWNS WITHIN THREE DAYS PRIOR TO TIME 13- GLASS ENCL6§0"IRE5 A�C?Af' SHOW50!Y•AND TUBS SHALL BE IN COMPLIANCE WITH THE 2020 NYSRC., GOVERNING CODE REQUIREMENTS. 7:.%7:..,. REQUIRED TO BE SHUTDOWN. 8- ALL MATERIALS SHALL BE NEW AS CALLED FOR IN 7NE ' RA WINGS AND THE BEST OF THEIR RESPECTIVE KINDS. THE CONTRACTOR 6- THE CONTRACTOR SHALL PROVIDE AND MAINTAIN ALL NECESSARY SAFEGUARDS SUCH AS GUARDRAILS BARRICADES, COVERING ETC. TO MASONR ::Plf fS::;.:.V.::.... ............I......... .................... WITHOUT WRITTEN APPROVAL OF THE ARCHITECT SHALL MAKE NO SUBSTITUTIONS. FOR PORTIONS OF THE WORK NOT SHOWN I DETAIL BUTPROTECT THE WORKMAN AND PUBLIC FROM ANY FORM OF BODILY INJURY. ;'.7.,.::.;• I;:PROVIDE.:WEEP»0)LES:::@:•:2'-0" O.C. WHICH ARE SHOWN GENERALLY, OR FOR REASONABLE INFERABLE AS BEING REQUIRED FOR A PROPER AND COMPLETE INSTALLATION, THE 7- PROVIDE AND MAINTAIN NECESSARY COVERINGS AND BOARDING TO PROTECT EXISTING WORK AND FINISHES TU-REMAIN. UPON ::.:: .:.PROVIDE-'WALVAIIZED WALL TIES TO ANCHOR BRICK. MATERIAL, METHODS, AND WORKMANSHIP SHALL CONFORM, AS A� MINIMUM, TO THE TYPICAL OR REPRESENTATIVE DETAIL THROUGHOUT THE COMPLETION, REMOVE ALL PROTECTION AND CLEAN DOWN ALL SURFACES AND LEAVE ALL CON5TRUGTfQf�L:jN. A CLEAN, ORDERLY CONDITION..:. `*�:.' 1ROWALL�P.EINFFORCED @ 16" O.C. VERTICALLY. ......... .... ..... CORRESPONDING PARTS OF THE BUILDING. DUST SHALL BE KEPT AT A MINIMUM WITH PROTECTIVE COVERING REQUIRED OVER EXISTING FINISHES (CARf?ET `ETC.) TO BE PROVIDED. 4.'-ExPANJ51ON JOINJF-5 @ 30'-O" O.C. VERTICALLY (MAX.) AND AT INTERSECTIONS. q- NO MATERIALS OF ANY KIND SHALL BE: USED UPON THE WORIK UNTIL IT HAS BEEN INSPECTED AND ACCEPTED BY THE OWNER. ALL 8- THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ANY DAMAGE CAUSED BY IMPROPER--PROTECTION -A..a- 5HALL MAKE ALL REPA{{�5• " MATERIALS REJECTED SHALL BE IMMEDIATELY REMOVED FROM THE WORK AND NOT AGAIN OFFERED FOR INSPECTION. WITHOUT COST TO THE OWNER. 7. 7. ELECTRICAL:NOTES: 10- ALL WORK SHALL BE EXECUTED IN A WORKMANLIKE MANNER AND ALL MECHANICS SHALL BE SKILLED IN THEIR TRADE. q- ALL REMOVALS SHALL BE NEATLY AND SAFELY DONE CAUSING NO DAMAGE TO WORK"10. REMAIN:: DEBR15*-A-NE)"RUBBISH;':SHAf:L NOT"BE':%::'. 1. ALL ELECTRICAL t}!ORK SHALL BE CONFINED TO THE SPACE AND LOCATION ALLOWED FOR IT, AND SHALL BE IN STRICT CONFORMANCE TO THE 7 ' %V.'.7::.. NATIONAL ELECTRICAL CODE, GOVERNING MUNICIPALITY AND NFPA 72. II- ITEMS SHOWN ON PLANS BUT NOT SPECIFICALLY STATED IN THE SPECIFICATIONS AND/OR VICE VERSA SHALL BE CONSIDERED TO BE ALLOWED TO ACCUMULATE AND SHALL BE PROMPTLY DISPOSED OF LEGALLY. " " INCLUDED IN THE CONTRACT. 10- MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN, KEEP IN SERVICE AND PROTECT A 3 T DAMAGE DURING:E. LITION OPERATIONS..'.: ., . 2. PROVIDE SEPARAITE CIRCUITS FOR ALL APPLIANCES AMPERAGES BASED ON MANUFACTURES SPECIFICATIONS. 3. CONTRACTOR IS TO VERIFY WITH THE OWNER IF THE OWNER WILL BE PURCHASING APPLIANCES AND HAVING THEM INSTALLED BY OTHERS PRIOR 70 CODE COMPLIANCE EXCAVATIONS AND SUBSURFACE SOIL CONDITIONS SUBMITTING A BID ON THE PROJECT, I- ALL CONTRACTORS AND SUB-CONTRACTORS SHALL BUILD IN COMPLIANCE WITH ANY AND ALL APPLICABLE 2020 NYSRC. I- CONTRACTOR SHALL STRIP ALL TOPSOIL FROM EFFECTED AREAS OF THE SITE AND SAVE FOR REDISTRIBUTION. THE COi�T:RACTOR SHALL 4. CONTRACTOR SNAILL INSTALL, AS PER OWNERS DIRECTION ANY AND ALL INTERCOM ALARM THERMOSTAT, TELEPHONE AND/OR TV ANTENNA WIRING CODES AS WELL AS THE REQUIREMENTS OF LOCAL AGENCIES. THESE RESPONSIBILITIES INCLUDE BUT ARE NOT LIMITED TO MATERIALS, THEN REMOVE ALL EXCESS EARTH FROM THE SITE. IN WALLS PRIOR TO'.SHEETROCKING. ALL WIRING SHALL BE BOARD OF FIRE UNDERWRITERS APPROVED 10 0EXCAVATION H CONTRACTORSHALL I E:: . :A.f S OF ALL BELOW BADE UTILITIS`':{NA .ER AND SEWAC,E LINES AND INCLUDE THE: FOLLOWING: EQUIPMENT, APPLICATIONS / INSTALLATIONS THE PROPER SEQUEENCE OF TRADES AND PHASES OF CONSTRUCTION FILING PROCEDURES, AND 2 PRIOR T THE LL VER FY TN QG.;;�;? 1.. G r.•:: , .... A) ALL WIRING FOR NEW SWITCHES, OUTLETS, FIXTURES, RE-CIRCUITING NECESSARY TO ALLOW FOR ALL NEW WORK ALL REWIRING OF EXISTING GENERAL ACCEPTABLE BUILDING PRACTICES OUTLINED BY THESE: CODES. THESE REQUIREMENTS SHALL PERTAIN TO THE PROPERTY DRYWELLS, SEPTIC SYSTEMS, AND ANY OTHER FACIL'I-TFffS.. ..::. ::. 3- ALL EXISTING FILL ROOTS AND OTHER UNSUITABLE BEARING MATERI'A1:.'�IALL BE REMOVED AND FOOTINGS.CARR-TEf 70 THE BOTTOM OF FIXTURES AND LABELING OF CIRCUIT BREAKERS TO INDICATE CIRCUIT USE. ADDRESSED HEREIN AS HELL AS ANY NEIGHBORING PROPERTIES THAT NAY BE AFFECTED BY IT'S ALTERATION. BE IT KNOWN THAT ALL r B) FURNISH NFBU CERTIFICATE AT COMPLETION OF WORK, NOTES AND SPECIFICATIONS SHOWN HEREIN, WHICH MAKE REFERENCE TO SAID RESPONSIBILITIES ARE RECOMMENDATIONS OF TNI5 OFFICE SUCH EXCAVATION. S. SMOKE ALARMS SENALL BE INSTALLED IN EACH SLEEPING ROOM OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE AND ARE SUBJECT TO CHANGE AS PER ANY GOVERNING AGENCIE`.5 AND REPRESENTATIVES THEREOF ANY DISCREPANCIES WHICH MAY ARISE 4- ALL FOOTINGS SHALL BEAR ON VIRGIN SD}L HAAi-'::-A.MINIMUM BEARING CAPACF -`gF TWO (2.)..TONS PER:5QUARE FOOT. CONTRACTOR TO BEDROOMS, AND ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING BASEMENTS AND ATTACHED GARAGES BUT NOT INCLUDING CRAWL SPACES BETWEEN THESE DRAWINGS AND SAID REQUIREMENTS SHALL BE BROUGHT TO THE ARCHITECT'S/REPRES./REPRES. ATTENTION BEFORE VERIFY ASSUMED SOIL-BEARING CAPACITY A0.SHALC''ASSUME FULL RESPONSIBILITY':FOR•.SAME':*:::*CONTRACTOR TO NOTIFY THE ARCHITECT AND UNIHABITABLE ANTICS. SMOKE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL WILL ACTIVATE THE COMMENCEMENT OF WORK IN QUESTION. OF ANY SOIL VARIATION OR COND1I IORI:.'ADVERSELY AFFEL :fS :ASSUMED.J3 A�}A1G..CAPM-_tT-f.;PRIOR 1 1`HE POURING OF ANY FOOTINGS. ALL OF THE ALARMS, IN THE INDIVIDUAL UNIT. THE ALARM SHALL BE CLEARLY AUDIBLE IN ALL BEDROOMS OVER BACKGROUND N015E LEVELS WITH ALL .. .::.. 2- EACH CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS OF THE FIRE CODE OF NEW YORK STATE NEW YORK STATE ENERGY 5- IN THE EVENT THAT THE.QQNTRACTOR DISCOVERS CLAT;'SILT, .Q.R..O.THER`�kt.t.THE-CMTRACTOR SHALL COORDINATE A TEST BORING IN INTERVENING DOORS iCL05ED. ONE CENTRALIZED ALARM HORN FOR ALL SMOKE DETECTORS IS PROHIBITED. CARBON MONOXIDE ALARMS SHALL BE A 0 S N A AND ALL OF THE LOCAL GOVERNMENT AGENCIES HAVING JURISDICTION INSOFAR AS APPLICABLE ACCORDANCE WITH THE OWNER"+:-[flNTRAf- CIF*:'AGREEMENT TO VERIFT:T-J4E PRESUMED MININU.M BEARING CAPACITY. INSTALLED IN EACH DWELLING UNIT ON ANY STORY HAVING A SLEEPING AREA, AND ON ANY STORY HAVING FUEL-FIRED OR SOLID-FUEL "APPLIANCES CONSERVATION CODE FEDERAL , ENT", FIREPLACES, OR ATTACHED GARAGES. CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE TO NI5 PORTION OF THE WORK. 6- ALL EXTERIOR FOOT- 1 ..;SHALC. E:•A MINtNbf`?-:OF 3'-0" BELOW GRA13E::t NLE55 RIFTED OTHERWISE IN PLANS. AND SQUIRM ACTUATION OF ONE ALARM WILL WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. THE ALARM SHALL BE CLEARLY AUDIBLE IN ALL 3- NO NOTE OR DETAIL OR LACK TNEREO= SHALL BE CONSTRUED AS RELIEVING THE CONTRACTOR FROM AN EXECUTION OF ALL WORK IN CONCRETE t FMU XION NOTES: .. BEDROOMS OVER BACCKGROUND N015E LEVELS WITH ALL INTERVENING DOORS CLOSED. ONE CENTRALIZED ALARM HORN FOR ALL CARBON MONOXIDE ACCORDANCE WITH ALL STATE AND LOCAL_ CODES. I- PERFORM.REQU1RPp:::AL`(ERAT}ONS T©`EXISTING:CONCRETE. NEW WORK 1 T:AfLED ADJACENT TO AND CONNECTING WITH PRESENT WORK DETECTORS 15 PROIIIBITED. PERMITS, INSPECTIONS AND APPROVALS SHALL MATtI.:EXIST'[fi�I�':;:JOINTS:':BFTWEEN NEW ANMEXISTING WORK SHALL BE TROWELED SMOOTH AND EVEN. PROVIDE EXPANSION JOINTS 6. CONTRACTOR SF'AILL VERIFY WITH THE OWNER, LOCATION AND QUANTITY OF LIGHTING FIXTURES, SWITCHES, OUTLETS, ETC. PRIOR TO PROVIDING BID I- UNLESS OTHERWISE AGREED UPON BETWEEN THE ARCHITECT AND THE OWNER THE OWNER SHALL PAY FOR AND THE CONTRACTOR SHALL AS:If?UIRED;: ON PROJECT. 0 NIN MUNICIPALITY10 0 STARTING AN WO 2- .F�tNGS.-'AT DIFFEREAI7-�tEVELS 5H`h '- .'S:.i PEED 50 THAT THE CLEAR DISTANCE BETWEEN ADJACENT BOTTOM EDGES SHALL NOT 7. PROVIDE A MIN111U1M OF ONE OUTLET IN A HALLWAY THAT EXCEEDS q'-0" IN LENGTH. OBTAIN A BUILDING PERMIT FROM THE VILLAGE, TOWNSHIP OR GOVERNING G PRIOR T Y RK. EXCEE0:.'-.:.5LOPE OF ONEVERTICAL TO TWO HOP,'ONTAL OR DEPENDENT UPON LOCAL GOVERNING CODES WHICHEVER IS PREVALENT. B. PROVIDE ONE ouTILET W EACH Roots A MINIMUM of 6'-0" FROM THE ENTRANCE TO THAT ROOM. 2- THE CONTRACTOR SHALL OBTAIN ALL REQUIRED APPROVALS PERMITS, CERTIFICATES OF OCCUPANCY INSPECTION APPROVALS, ETC. FOR::::::... q. PROVIDE A MINIf1U)M OF ONE G.F.C.I. OUTLET WITHIN 3'-0" OF ANY SINK AND A MINIMUM OF ONE IN EVERY BATHROOM UNLESS OTHERWISE SPECIFIED. WORK PERFORMED FROM AGENCIES HAVING; JURISDICTION THEREOF. • ._--- =:.. ...: .... UNDATIONS SHALL BE POURED CONE}NtkT41f.5LY. IF POUR IS INTERRUPTED A VERTICAL KEY SHALL BE PROVIDED. 10. CONTRACTOR MU5')T VERIFY WITH NI5 LICENSED ELECTRICIAN IF AN UPGRADE OF ELECTRICAL SERVICE IS REQUIRED FOR THIS PROJECT PRIOR TO 3- THE CONTRACTOR SHALL HAVE A COMPETENT REPRESENTATIVE OR FOREMAN PRESENT, WHO SHALL FOLLOW WITHOUT DELAY ALL "Cep..... A..:.JOINTS ARE NOT:PERMITTED. SUBMITTING A BID. INSTRUCTIONS OF THE OWNER OR HIS/HER ASSISTANTS IN THE PROSECUTION AND COMPLETION OF THE WORK IN CONFORMITY WITH THIS...: ::.. 4-:::CQNTRAGT0R SHALL VERIF:x:-'*fffIlENSIONS AND LOCATIONS OF SLOTS, PIPE SLEEVES, INSERTS, ANCHOR BOLTS, ELECTRIC CONDUITS, ETC. II. CONTRACTOR0 ERI LOCATIONS 0 MA - T VERIFY L T F MASTS, METERS, SUB PANELS, ETC. FOR RELOCATION AS REQUIRED FOR THE PROJECT. CONTRACTOR MUST CONTRACT, AND SHALL HAVE FULL AUTHORITY TO SUPPLY LABOR AND MATERIALS IMMEDIATELY. THE CONTRACTOR SHALL•�A: W- HAVE A.:.:.:.. AS REQUIRED FOR TRADES BE.FOR�E:f'LA {fJG CONCRETE. ALSO NOTIFY THE AR'.CNITECT OF LOCATIONS IF NOT SHOWN ON PLANS PRIOR TO COMMENCEMENT OF WORK BIDDING. COMPETENT REPRESENTATIVE AVAILABLE TO RECEIVE TELEPHONE MESSAGES AND PROVIDE A REASONABLE REPLY AS:SOON AS:AOSSIBLE; : :::..5- A CONCRETE:.5. OCK FOUNDATION. WA1 L.:.:SHALL BE ACCEPTED IN LIEU OF POURED CONCRETE WHERE PERMITTED BY LOCAL CODES. .: ...*6= FOR CRAWL S1�ACES, BASEMENTS AND CELLARS, ANCHOR BOLTS SHALL BE 5/8" DIA. WITH MINIMUM EMBEDDMENT OF IS" FOR MASONRY BUT NOT LATER THAN 24 HOURS. :: FIREPLACE NOTES: :'.:':: 4- THE CONTRACTOR. SHALL AT ALL TIMES PROVIDE CONSTANT AND EASY ACCESS AND SAFE PROPER FACILETI.EES:.FOR TiI�::.fNSPECTfQ�t. ::: WALLS'AN1T7.7`;FOR:ROklRFD COW.,RETE WALLS. THERE SHALL BE A MINIMUM OF TWO BOLTS PER SILL MAX. ONE FOOT FROM CORNERS AND OF ALL PARTS OF THE WORK. I "" 6" FROM EN1p CQNDITIONS':AND'SPACED THEREAFTER A MAX. 48" O.C. FOR SINGLE STORY STRUCTURES AND 3'-O" O.C. FOR TWO STORY I. FIREPLACE CONSTRUCTION SHALL COMPLY WITH SECTION 7813.5D OF N.Y. STATE ECCC WITH A MAXIMUM OF 20 CFM AIR INFILTRATION LOSSES WITH DAMPER IN 5- THE CONTRACTOR SHALL POST THE PERMIT ON THE JOB SITE AS PER BUILDING CODE REQUIREMENT :.:IN.::.AN COtISPICUOUS' f 1ACE. STRUCTURES t f a3" 6.E- FOR THREE STORY STRUCTURES. NOTE THAT TWO STORY STRUCTURES WITH ROOF SLOPES EQUAL TO OR CLOSED POSITION . 2. FIREPLACE UNIT 5INALL BE PROVIDED WITH 150 CFM OUTSIDE AIR INTAKE DUCT (DAMPERED). GREATER THAN 'fi={ SHALL BE CONSIDERED THREE STORIES. 3. FIREPLACE TO BE "SUPERIOR" MODEL WITH OPTIONAL GLA55 DOOR ASSEMBLY AND OUTSIDE COMBUSTION KIT INCLUDED. `.7.'.'.7.' 7- FOR SLABS OW-GRADE AND LOCATIONS WHERE THE EXTERIOR WALL PLATE BEARS DIRECTLY ON THE FOUNDATION WALL ANCHOR BOLTS PAYMENTS TO THE CONTRACTOR SHALL BE 5/8" DIA. WITH MINIMUM EMBEDMENT OF 18". THERE SHALL BE A MINIMUM OF TWO BOLTS PER SILL MAX. ONE FOOT FROM 4. FIREPLACE SHALL BE INSTALLED AS PER MANUFACTURERS WRITTEN SPECIFICATIONS. .......... . CORNERS AND 6 FROM END CONDITIONS AND SPACED THEREAFTER A MAX. 33 O.C. dALL SHIELDS ON BOTH SIDES OF FIREPLACE OPENING (SUPERIOR W540 OP. EQUAL). 5- BEFORE ANY PAYMENT WILL BE MADE BY THE OWNER THE CONTRACTOR SHALL DELIVER TO THE OWNER ANY;�IiIVER OR R�k:EASES��>OF ,I „ � 5. PROVIDE METAL W ANY LIENS ARISING OUT OF HIS CONTRACT FOR WORK COMPLETED AS OF THE DATE OF THE REQUEST FOR PAYMENT. 6. CHIMNEY EY OUTLETS SHALL NOT BE LOWER THAN THE TOP OF ANY WINDOW WITHIN 15-0 OR LESS THAN 2-0 ABOVE ANY COMBUSTIBLE PART OF THE ROOF WITHIN 6- THE CONTRACTOR SHALL ALSO FURNI5I I EVIDENCE SATISFACTORY TO THE OWNER THAT ALL PAYROLLS BILLS FOR.NABi R, MAT I2fALS.......:.•....•:.8- PROVIDE CONTINUOUS METAL TERMITE SHIELD WITH ALL JOINTS SEALED ALONG PERIMETER WALLS AND SHIELDED TERMITE COLLARS AT 101 OII ��-:�:-PfUMBING PIPES IN CRAWL SPACES UNLESS OTHERWISE NOTED. AND EQUIPMENT, AND OTHER INDEBTEDNESS CONNECTED WITH HIIS WORK FOR WHICH THE OWNER OR NI5 PROPERTY.;•f71GHT IK:'-ANY W�kY.BE,....... ...... q MINIMUM COMPRESSIVE STRENGTH OF CONCRETE AT 28 DAYS TO BE AS FOLLOWS: PLUMBING NOTES: RESPONSIBLE, HAVE BEEN PAID OR OTHERWISE SATISFIED. A) FOOTINGS PIERS FOUNDATION WALLS: Ft = 3 500 P.S.I. STONE CONCRETE. 7 ' ' r I. ALL PLUMBING WORK SHALL BE IN STRICT CONFORMANCE WITH ALL STATE AND LOCAL CODES. V. :::' INSURANCE AND WARRANTIES B) SLAB ON GROUND: Ft = 2,500 P.S.I. CONCRETE. 2. NOT WATER HEATER SHALL HAVE A MAXIMUM TEMPERATURE SETTING OF 140 DEGREES F. C SUPERSTRUCTURE, SLAB: Ft = 3,500 P.S.I. CONCRETE. 3. PROVIDE NOT AND) COLD WATER SUPPLY LINES TO A NEW REFRIGERATOR AS REQUIRED BY MANUFACTURES SPECIFICATIONS. I- EACH CONTRACTOR AND SUB-CONTRACTOR SHALL SUBMIT PROOF OF INSURANCE WITH A COMPANY IN-5UUD BY THE 5- AT:E OF-``NEW YORK ) HAVING COVERAGE FOR THE TYPES OF WORK SPECIFIED WITHIN THI5 BID PACKAGE IN THE AMOUN.5 AN11�:.:PERIOD5 SATISFAL--TORY TO THE D)3500 P.5.I.,MIN.COMPRE551VE STRENGTH OF CONCRETE FOR GARAGE SLAB. 4. PROVIDE INSULATION ON ALL NEW PIPING AS REQUIRED BY CODE. OWNER. THE PROOF OF INSURANCE SHALL BE AS FOLLOWS: COMMERCIAL GENERAL LIABILITY,• COf?fRACT1Af:.RFRSONAL INJURY E)CONCRETE TO BE 5 TO 7% AIR-ENTRAINED,PER R 402.2 OF RCNYC 5. REMOVE AND RELOCATE ALL EXISTING PIPING AS REQUIRED TO ASSURE THE PROPER EXECUTION OF THE WORK. AUTOMOBILE LIABILITY, MEDICAL PAYMENTS AND UMBRELLA LIABILITY. FAILURE TO 51QBMIT CERTIFICATE OF-::Ii� IURANCE MAY CAUSE YOUR 10- ANTI-HYDRO SHALL BE ADDED IF POURING TAKES PLACE AT 32 DEGREES F OR LESS. 6. BELOW GROUND WASTE LINES SHALL BE X.H.C.I. PIPING. 7. POTABLE LINES SHALL BE TYPE "L" COPPER. BID TO BE DISQUALIFIED. 8. THE PLUMBING CONTRACTOR SHALL PERFORM ALL REQUIRED GAS OR OIL PIPING AND VERIFY ANY SITE CONDITIONS t REQUIREMENTS •• .. PERTAINING TO THERETO (IE. RELOCATION, UPGRADING, ETC)-PRIOR TO BIDDING AND COMMENCEMENT OF ANY WORK. ' q. SANITARY DISPOSAL SYSTEM SHALL BE COUNTY DEPARTMENT OF HEALTH SERVICES APPROVED FOR DESIGN AND INSTALLATION. THE OWNERS SURVEYOR SHALL BE RESPONSIBLE FOR DE51GN LOCATIONS OF THE FACILITIES AS WELL AS OBTAINING ALL PERMITS OR - 5HEET TITLE GONSTRUGTION DOCUMENTS .......... ......... APPROVALS. � �AF�� .. 10. WATER MAIN MUST BE 7-0 AWAY FROM THE SANITARY DISPOSAL SYSTEM AND 4-0 DEEP.12. IN BEARING WALLS OR PARTITIONS NO '"}"- °� �' Iln ......:::':'... V.'..: :_... STUD 15 TO BE CUT MORE THAN 1/3 IT'S DEPTH TO RECEIVE PIPING, DUCT OR ELECTRICAL WORK. ' ' - L'0 1 a a PROJECT NAME BURKE RESIDENCE . .�� : ,. d �r 780 WINDJAMMER DR.-SOUTHOLD,W-11q 11 !s "'lU • • OYSTER BA1' DRAFTING SHEET NO. 2-14-25 `' �� d� AND ARCHITEGTUi�E, F.C. DATE: Q� "iFi h jd :_, ' _ 11 SCALE: AS NOTED OF d ti 68 WEST MAIN STREET OYSTER BAY, N.Y. 11771 .... "� =�a �� �? ova (516) C122-5Q76 (FAX) C122-6255 BY: M.M. v WEB: WWW.OYSTERBAYDRAFTIN6.GOM EMAIL: ARCHITECT®OY5TERBAYDRAFTING.COM JOB NO: 2'JO rJ" 0