Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
52857-Z
of souryOlo Town of Southold * * P.O. Box 1179 io 53095 Main Rd CouNV off' Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 47076 Date: 05/19/2026 THIS CERTIFIES that the building As built additions/alterations Location of Property: 645 Hamilton Ave Mattituck,NY 11952 Sec/Block/Lot: 140.-2-1 Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 11/10/2025 Pursuant to which Building Permit No. 52857 and dated: 04/13/2026 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "As built" alterations including a conversion of a roofed over porch into habitable living space, to an existing single-family dwelling as applied for. The certificate is issued to: Showalter Holdings LLC Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 26-469 5/14/2026 PLUMBERS CERTIFICATION: Connor Ravan 5/18/2026 Autho ' ed Signa �'of sou,yo TOWN OF SOUTHOLD BUILDING DEPARTMENT • o SOUTHOLD, NY �`�Qourrtr.a� BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52857 Date: 04/13/2026 Permission is hereby granted to: Schowalter Holdings LLC 1015 Orchard Ln Southold, NY 11971 To: Legalize "as built"alterations to an existing single-family dwelling as applied forto convert a roofed over porch into habitable living space as well as reconfigure the floor plan as applied for.Additional certification may be required. Premises Located at: 645 Hamilton Ave, Mattituck, NY 11952 SCTIVI# 140.-2-1 Pursuant to application dated 11/10/2025 and approved by the Building Inspector. To expire on 04/12/2028. Contractors: Required Inspections: Fees: As Built Alteration $640.00 CO Single Family Dwelling-Addition/Alteration $100.00 Total $740.00 v-P er Building Inspector East End Inspection Agency, LLC P.O. Box 35 East Quogue, New York, 11942 EEI (631) 594-2272 Fax (631) 594-2598 offices@eastendinspectionagency.com East End Inspection Agency CERTIFICATE OF ELECTRICAL COMPLIANCE This Certificate of Compliance is limited to the inspection and compliance of electrical equipment and/or work described below, installed by the applicant and not after the final inspection date listed. Owner: Showalter Holdings Date: May 14, 2026 Address: 1015 Orchard Lane Certificate No: 26-469 Southold, NY 11971 Location of Property Inspected 645 Hamilton Ave Mattituck, New York STCM Dist 1000 Section: 140.0 Block: 2.00 Lot: 1.000 Permit Number 52857 [X]As Built [X] Residential [X] Basement [X] 1 st Floor [X] 2nd Floor [X] Service Fixture Outlets- 12 Ranges- 1 40 Amp Outlets-46 CO Det-4 GFCI Receptacles-5 Service Disconnect- 1-cb Existing ,� 9 Oil Heat- 1-2 Frac 1-10-80 Smoke Det-8 Other Fixtures- 12 led Electric Service-200 Amp existing Special Rec. -2-20 Amp � c ���y Service Cond Size- 1 set 2/0 copper. Meters- 1 1-12-200 No visual defects observed Switches- 11 Date of Roughing Inspection: Date of Final Inspection: 5/12/2026 The electrical work and /or equipment described above were inspected and appear to be in compliance with local, state and national electrical code requirements at the time of inspection. Installer: Homeowner License Number: N/A Electrical Inspector: , Edward Seltenreich OF 04 Town Hall Annex Telephone(631)765-1802 54375 Main Road C) P.O.Box 1179 CA ff Southold, NY 11971-0959 4,- 8 MAY 2026 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: Building Permit No. Owner:-J-hotuafteK N/d1ffzas U,(� (Please print) Plumber: (Please print) T certify that the solder used in the water supply system contains less than 2/10 of I% lead. (Plumbers Signature) Sworn to before me this day of 6-A)M4— 20 CONNIE D.BUNCH " a Notary Public,State of New York yVN0 No.01 BU6185050 Qualified In Suffolk County Commission Expires April 14, Notary Publig$r444k County U Profes,bional Hume Inspecdoin 5.Hard1M..dL-Place Lake Grove,NY 1.17SS 631-335-9773 Steven 1101MY Dr. NYS Professional Engineering License#067448 Profess-tonal Home Inspection Prefiasslanalffl.com StevenNioltzOgmail.com May,12,2026 00% J: 1, Steven Holtz, am a licensed New York State Professional Engineer and I have physically inspected the property at 645 Hamilton Ave, Mattituck, NY 11952 and I have, reviewed the current as-built survey and I verify the following: • Zoning Compliance: Confirmation that the footprint, setbacks, Gross Floor Area (GFA), and sky plane fall within local zoning limits. . • Building & Safety Codes: Verification that the structural, electrical, plumbing, and fire safety systems comply with the NYS Building Code. • Deviation Justification: I reviewed the approved drawings and did not find any discrepancies between the originally approved drawings (if any) and the actual as-built conditions. • Seal and Signature: The letter is formally stamped, signed, and dated by me. oF NE� 4 P Co 0 �OARO0 74 SS1 OF SOUTyo� TOWN OF SOUTHOLD BUILDING DEPT. 000er+��'' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ k-1--riNAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] 'FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ q--RENTAL REMARKS: Save. Me a!5 V&P-4a. -1�i2A,►�n i ,� �� l / � r G C V 1 (�biti 12 D , gee,s�Vl 'fy �� DATE �"�-a� INSPECTOR i OF SOGTy�Io # # TOWN OF SOUTHOLD BUILDING DEPT. o m ago 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [WMENTAL REMARKS: GcJ4, Sk0v✓c /its /s a s/o�, � vow- ,od 43p5 r a b)k DATE INSPECTOR i FIE,LD INSPECTION REPORT DATE--F- COMMENTS ................. FOUNDATION (1ST) ------------------ ---------------- --- ----- ---------- ................ FOUNDATION (2ND), .............. ROUGH FRAMING & PLUMBING ----------------- �j INSULATION PER N. Y. .. .............STATE ENERGY CODE ----------- --- ------- ------- 711 -"r New FINAL a/0- .......... L-V1119wa e- ............ .......................... ............. U151 GtS ADDITIONAL COMMENTS L 0 ........ ------- - ------------ ................... ------ h6 ........... ................... ............ ....... .. ........... ------ ............. ............. -------- ............ ....... ....... �0���,11FF0(�cOGy TOWN OF SOUTHOLD—BUILDING DEPARTMENT y z Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov_ Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only U PERMIT NO. Building Inspector: A NOV 1 0 2025 � Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,an DS'iA att Dep artrr;ant Owner's Authorization form(Page 2)shall be completed. Tol""n of:30u.how Date: ` 0 02 Do2S OWNER(S)OF PROPERTY: Name: S•CTM #10.007 Project Address: n - - Dru .. Phone#: Email: <.. � `-('.�•'��S5v1.. Mailing Address: DrGdlard. CQL -S61,LkbC _ 1. . - '�- CONTACT PERSON: Name: .. Mailing Address: I D P. 0-1 Cha flit LA:fhO Ld 1 [Ci Phone#: Email: DESIGN PROFESSIONAL INFORMATION: Name: ,r - C... l .. .,b 3 Mailing Address: Phone#: Q 0S- .DO 3 — _. -_... __.. Email: C.. -�.3 h��m�.S Co _fneU* y com CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: Other As—b-tI.t $ Will the lot be re-graded? ❑Yes Pqqb� Will excess fill be removed from premises? ❑Y s to 1 PROPERTY INFORMATION Existing use of property: W51 Crcc N0 esslvw' Intended use of property: 0 1 _ _ ks;I new Zone or use district in which premises is situated: Are there any covenants anorestrictions with respect to ! this property? ❑ o Yes EP IF YES, PROVIDE A COPY. Q IG�,2�l�1a ( t ❑ Check Box'After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of,the Town Code -APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit'pursuant to the Building Zone Ordinance of the Town of Southold;Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, . additions,'aiterai ions or fo'r removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,_ housing code and regulations and to admit authorized inspectors on premises-and in buildings)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By t name): ZO e__ U27 l► ❑Authorized Agent Downer Signature of Applicant: Date ONNIE D'BUNCH N ary Public,State of New York STATE OF NEW YORK) No.61BU6185050 Qualified In Suffolk County SS: Commission Expires April 14,2 COUNTY OF ) being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)he is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of 1 V(D ye-m)&[. , 20t:� Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 GENERAL NOTES RESIDENTIAL CODE OF NY STATE(RCNYS 2020) BUILDING ENVELOPE NOTES AS-BUILT DOCUMENTATION FOR EXISTING ONE-FAMILY DWELLING CORY HOLMES, PE CSI3HOLMES@GMAIL.COM 1. ALL AS-BUILT WORK SHALL COMPLY WITH THE RESIDENTIAL CODE OF NEW YORK STATE 1. THE BUILDING ENVELOPE SHALL COMPLY WITH THE RESIDENTIAL CODE OF NEW YORK 645 HAMILTON AVE,MATTITUCK,SOUTHOLD,NY 11952 (szo) 205-0832 (RCNYS 2020), BUILDING CODE OF NEW YORK STATE (RCNYS 2020), ENERGY STATE(RCNYS 2020),BUILDING CODE OF NEW YORK STATE(BCNYS 2020),AND ENERGY 1. THESE PLANS ARE PREPARED FOR BUILDING PERMIT PURPOSES FOR AN EXISTING SINGLE- CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE(ECCCNYS 2020),NATIONAL CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE(NYSECCC/ECCCNYS 2020) STAMP FAMILY RESIDENCE.A LICENSED PROFESSIONAL ENGINEER OR ARCHITECT WILL REVIEW ELECTRICAL CODE(NEC 2020-NFPA 70),AND APPLICABLE SUFFOLK COUNTY AND FOR ALL THERMAL,MOISTURE,AND STRUCTURAL PERFORMANCE REQUIREMENTS. AND CERTIFY COMPLIANCE WITH APPLICABLE CODES AND STANDARDS TOWN OF SOUTHOLD REGULATIONS. 2. ALL EXTERIOR WALLS,ROOFS,FLOORS,WINDOWS,AND DOORS SHALL MEET OR EXCEED ��OF NEW k, 2. THE DESIGN PROFESSIONAL IS NOT RESPONSIBLE FOR CONSTRUCTION ADMINISTRATION; 2. EXISTING CONDITIONS SHALL BE FIELD-VERIFIED AND DOCUMENTED ACCURATELY IN THE MINIMUM R-VALUES,U-FACTORS,AND SHGC LIMITS FOR CLIMATE ZONE 4 AS °RF ALL DUTIES,INCLUDING SITE SAFETY,SECURITY,AND ANY PROPERTY,VEHICLE,OR AS-BUILT DRAWINGS,INCLUDING DIMENSIONS,STRUCTURAL ELEMENTS,MECHANICAL, LISTED IN ECCCNYS TABLE R402.1.2. p EQUIPMENT DAMAGE,ARE SOLELY THE RESPONSIBILITY OF THE HOMEOWNER OR ELECTRICAL,AND PLUMBING COMPONENTS. 3. A CONTINUOUS AIR BARRIER AND VAPOR RETARDER,WHERE REQUIRED,SHALL BE r; GENERAL CONTRACTOR. INSTALLED IN ACCORDANCE WITH RCNYS SECTION R702.7 AND ECCCNYS R402.4,WITH m 3. STRUCTURAL ELEMENTS SHALL CONFORM TO BCNYS CHAPTERS 3 5 AND BCNYS ALL JOINTS,SEAMS,AND PENETRATIONS SEALED TO MINIMIZE AIR LEAKAGE. o` 3. GENERAL CONTRACTOR SHALL STUDY DRAWINGS,SPECIFICATIONS AND FIELD VERIFY REQUIREMENTS FOR FOUNDATIONS,FRAMING,LOAD PATHS,AND WIND RESISTANCE FOR rnalu, e2 GRADE, EXTENT AND COMPATIBILITY WITH THE EXISTING SITE CONDITIONS BEFORE CLIMATE ZONE 4(SUFFOLK COUNTY). 4. WALL AND ROOF ASSEMBLIES SHALL INCLUDE APPROVED FLASHING, °FESS%.NPR WEATHER-RESISTANT BARRIERS,AND DRAINAGE PLANES PER BCNYS SECTIONS R703 COMMENCING THE WORK.ANY DISCREPANCIES FOUND SHALL BE REPORTED IN WRITING 4. ANY MODIFICATION OR REPAIR TO LOAD-BEARING WALLS,BEAMS,OR FOUNDATIONS AND R903 TO PREVENT MOISTURE INTRUSION AND ENSURE LONG-TERM DURABILITY. 1 11/7/2025 PRIOR TO CONSTRUCTION. SHALL BE DOCUMENTED AND CERTIFIED AS EQUAL OR GREATER IN STRENGTH TO THE 5. ALL FENESTRATION SHALL BE NFRC-LABELED AND DEMONSTRATE COMPLIANCE WITH REVISION LOG 4. GENERAL CONTRACTOR&SUB-CONTRACTOR SHALL STRICTLY FOLLOW THE DRAWINGS ORIGINAL DESIGN. MAXIMUM U-FACTOR AND SHGC LIMITS,WITH INSTALLATION IN ACCORDANCE WITH &NOTES AND ENSURE ALL WORK COMPLIES WITH THE APPLICABLE STATE BUILDING 5. THE BUILDING ENVELOPE SHALL COMPLY WITH ECCCNYS 2020 MINIMUM INSULATION MANUFACTURER SPECIFICATIONS AND CODE-APPROVED FLASHING DETAILS. NO. REVISION CODES AND LOCAL AMENDMENTS. (R-VALUE) AND MAXIMUM U-FACTOR REQUIREMENTS FOR CLIMATE ZONE 4, WITH 6. BUILDING ENVELOPE ASSEMBLIES SHALL COORDINATE WITH STRUCTURAL SYSTEMS IN # 5. GENERAL CONTRACTOR SHALL FOLLOW THE MORE STRINGENT PROVISION OF THE VERIFIED LOCATIONS OF INSULATION AND AIR/VAPOR BARRIERS. ACCORDANCE WITH RCNYS CHAPTERS 3-5 AND BCNYS STRUCTURAL PROVISIONS, APPLICABLE BUILDING CODE IN CASE OF CONFLICTING CODE PROVISIONS. 6. WINDOWS,DOORS,AND SKYLIGHTS SHALL BE NFRC-LABELED AND MEET ECCCNYS ADDRESSING WIND,SNOW,AND UPLIFT LOADS APPLICABLE TO SUFFOLK COUNTY. TABLE R402.1.2 PERFORMANCE VALUES. INSTALLATION SHALL FOLLOW 7 MECHANICAL AND ELECTRICAL PENETRATIONS THROUGH THE BUILDING ENVELOPE EE 6. GENERAL CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UNDERGROUND OR OVER HEAD UTILITIES,INCLUDING SANITARY SEWER,WATER,GAS,AND ELECTRICITY BEFFOREORE SHALL MAINTAIN THE CONTINUITY OF INSULATION AND AIR BARRIERS,AND ALL LIGHTING MANUFACTURER'S INSTRUCTIONS AND CODE-APPROVED FLASHING DETAILS. OR EXTERIOR ELECTRICAL COMPONENTS SHALL COMPLY WITH NEC 2020 AND NYSECCC EXCAVATION OR CONSTRUCTION WORK. 7. MECHANICAL SYSTEMS SHALL BE VERIFIED FOR COMPLIANCE WITH RCNYS CHAPTER 15 EFFICIENCY REQUIREMENTS. 7. GENERAL CONTRACTOR SHALL ENSURE MINIMUM COVER FOR WATER LINES IS 4 FEET, AND NYSECCC HVAC EFFICIENCY REQUIREMENTS.ALL COMBUSTION APPLIANCES SHALL 8. SITE AND BUILDING ENVELOPE DOCUMENTATION SHALL INDICATE BUILDING LOCATION, FOR DRY UTILITIES IS 3 FEET,AND FOR PVC SEWER LINES IS 2 FEET. HAVE ADEQUATE COMBUSTION AIR AND VENTING. SETBACKS,GRADING,AND DRAINAGE IN COMPLIANCE WITH THE TOWN OF SOUTHOLD 8. GENERAL CONTRACTOR SHALL ENSURE ALL PAVED SURFACES SHALL BE AT A 0.5%MIN. 8. ELECTRICAL SYSTEMS SHALL COMPLY WITH NEC 2020 AND BE VERIFIED FOR CIRCUIT ZONING CODE(§280)AND SUFFOLK COUNTY AMENDMENTS ADDRESSING STORMWATER SLOPE.ALL GRASSED AND LANDSCAPED AREAS SHALL BE AT A 1%MINIMUM SLOPE. CAPACITY,GROUNDING,AFCVGFCI PROTECTION,AND PANEL LABELING.ALL EXISTING MANAGEMENT,FLOOD ZONES,AND COASTAL RESILIENCE. 9. GENERAL CONTRACTOR SHALL VERIFY REQUIRED PROPERTY SETBACKS,LOT COVERAGE CIRCUITS SHALL BE DOCUMENTED AND UPDATED WHERE NECESSARY. AND BUILDING HEIGHT LIMIT AS PER LOCAL ZONING ORDINANCE. 9. PLUMBING SYSTEMS SHALL COMPLY WITH THE NEW YORK STATE PLUMBING CODE FIRE SAFETY NOTES LOCATION PLAN 10.GENERAL CONTRACTOR SHALL ENSURE THE PROVISION OF CONTROL AND EXPANSION (NYSPC),WITH VERIFIED PIPE SIZES,MATERIALS, FIXTURE LOCATIONS,AND PROPER JOINTS ON THE CONCRETE DRIVES, WALKS, AND PATIOS AS MENTIONED IN THE VENTING AND TRAP INSTALLATIONS. DRAWINGS. 10.FIRE SAFETY SHALL BE VERIFIED PER RCNYS SECTIONS R302-11315, INCLUDING 1. ALL FIRE SAFETY PROVISIONS SHALL COMPLY WITH THE RESIDENTIAL CODE OF NEW 11.GENERAL CONTRACTOR SHALL COORDINATE ARCHITECTURAL, STRUCTURAL, FIRE-RESISTIVE CONSTRUCTION,PROTECTED PENETRATIONS,AND THE INSTALLATION OF YORK STATE(RCNYS 2020),FIRE CODE OF NEW YORK STATE(FCNYS 2020),AND ANY MECHANICAL, ELECTRICAL, PLUMBING & MILLWORK TRADES PROPERLY WITH SMOKE AND CARBON MONOXIDE DETECTORS AS REQUIRED. APPLICABLE ALARMS COUNTY AND TOWN OF ACCORDANCE AMENDMENTS. / RESPECTIVE SUB-CONTRACTORS TO ENSURE EFFICIENT SITE EXECUTION&ACTIVITY 11.ALL EGRESS DOORS,STAIRS,GUARDS,AND HANDRAILS SHALL COMPLY WITH RCNYS 2. ALL SMOKE ALARMS SHALL BE INSTALLED IN ACCORDANCE WITH RCNYS SECTION N SEQUENCING. CHAPTER 3 REQUIREMENTS FOR WIDTH,HEIGHT,RISE,RUN,AND SAFETY. R314,PROVIDED IN EACH SLEEPING ROOM,OUTSIDE EACH SLEEPING AREA,AND ON 11 * r rn 12.GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING SHOP DRAWINGS OF 12.SITE PLANS SHALL SHOW EXISTING STRUCTURE LOCATIONS, PROPERTY LINES,AND EVERY STORY OF THE DWELLING,INCLUDING BASEMENTS.SMOKE ALARMS SHALL BE cm r HARD-WIRED WITH BATTERY BACKUP AND INTERCONNECTED WHERE REQUIRED. Q Z T MILLWORK,STONEWORK&OUTDOOR STRUCTURES AS REQUIRED BY THE COUNTY OR SETBACKS PER TOWN D BUILDING H ZONING CODE§280 AND ANY LOCAL AMENDMENTS 3. CARBON MONOXIDE ALARMS SHALL BE INSTALLED PER RCNYS SECTION R315 L,L J Z PERMITTING AUTHORITY. FOR LOT COVERAGE AND BUILDING HEIGHT. OUTSIDE OF AND WITHIN PROXIMITY TO ALL SLEEPING AREAS AND IN ANY DWELLING Z J o 13.GENERAL CONTRACTOR SHALL CONTACT 811 AND OBTAIN UTILITY-LOCATE CLEARANCE 13.GRADING,DRAINAGE,AND STORMWATER MANAGEMENT SHALL CONFORM TO TOWN OF UNIT THAT CONTAINS FUEL-FIRED APPLIANCES OR HAS AN ATTACHED GARAGE. /r d W WELL IN ADVANCE OF ANY EXCAVATION,FOLLOWING THE REQUIRED NOTICE PERIOD AND SOUTHOLD AND SUFFOLK COUNTY REGULATIONS, INCLUDING REQUIREMENTS FOR 4. ALL FIRE-RESISTANCE-RATED CONSTRUCTION,INCLUDING WALLS,FLOORS,CEILINGS, / r r t,. 0 CD SCHEDULING GUIDELINES. COASTAL,FLOOD,AND STORM RESILIENCE AREAS. AND STRUCTURAL MEMBERS,SHALL COMPLY WITH RCNYS SECTION R302. F G F 14.THE CONTRACTOR SHALL ENSURE A PROPERLY CONSTRUCTED BUILDING ENVELOPE WITH 14.AS-BUILT DOCUMENTATION SHALL INCLUDE UPDATED FLOOR PLANS, ELEVATIONS, ASSEMBLIES BETWEEN DWELLING UNITS,GARAGES,AND HABITABLE SPACES SHALL _ CD CONTINUOUS AIR-TIGHTNESS AND ADEQUATE INSULATION, DEMONSTRATING STRUCTURAL DETAILS,MECHANICAL AND ELECTRICAL LAYOUTS,AND SITE INFORMATION MAINTAIN THE REQUIRED FIRE SEPARATION AND RATING. •. �7 HIGH-QUALITY WORKMANSHIP THROUGHOUT AS VERIFIED ON SITE. 5. PENETRATIONS OF FIRE-RESISTANCE-RATED ASSEMBLIES BY PIPES,DUCTS,CABLES, , \ �r - - _ t L" J U 15.ALL WORK SHALL BE SUBJECT TO REVIEW AND APPROVAL BY THE TOWN OF SOUTHOLD p- 15.GENERAL CONTRACTOR SHALL RESPONSIBLE FOR SUBMITTING THE BUILDING PERMIT ACCORDANCE WITH RCNYS SECTION R302.11 TO MAINTAIN THE INTEGRITY OF THE APPLICATION TO THE RELEVANTT COUNTY/CITY AND PROVIDING REQUIRED SUPPORTING BUILDING DEPARTMENT.ANY FIELD CHANGES SHALL BE DOCUMENTED IN THE FINAL OR CONDUITS SHALL BE PROTECTED WITH APPROVED FIRESTOPPING MATERIALS IN , AS-BUILT PACKAGE PRIOR TO PERMIT CLOSE-OUT. FIRE BARRIER. u- DOCUMENTS,ENSURING COMPLIANCE WITH LOCAL PERMITTING REQUIREMENTS. a. , " C j � Q 6. EXTERIOR WALL OPENINGS AND PROJECTIONS SHALL COMPLY WITH THE FIRE // 16.GENERAL CONTRACTOR SHALL COORDINATE DIRECTLY WITH THE LOCAL BUILDING 16.ACCESSIBILITYFEATURES,WHERE APPLICABLE,SHALL FOLLOW THE BUILDING CODE OF SEPARATION DISTANCE REQUIREMENTS OF RCNYS TABLE R302.1(1)BASED ON DEPARTMENT FOR SCHEDULING,RE-INSPECTIONS,AND DOCUMENTATION. NEW YORK STATE (BCNYS 2020) FOR UNIVERSAL DESIGN AND REASONABLE DISTANCE TO PROPERTY LINES AND ADJACEPTi STRUCTURES AS REQUIRED BY THE 17.GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING AND QUALIFYING ACCOMMODATION,EVEN THOUGH SINGLE-FAMILY DWELLINGS ARE GENERALLY EXEMPT TOWN OF SOUTHOLD ZONING CODE. BUILDING INSPECTIONS,INCLUDING FOUNDATION,FRAMING,HOUGH-IN TRADES,AND FROM ADA REQUIREMENTS. 7. HEATING EQUIPMENT,FIREPLACES,AND CHIMNEYS SHALL BE INSTALLED IN J z PROJECT INFORMATION CODE COMPLIANCE GETTING OCCUPANCY CERTIFICATE. 17.ALL UTILITY CONNECTIONS,INCLUDING WATER,SEWER,GAS,AND ELECTRIC SERVICE, ACCORDANCE WITH RCNYS CHAPTERS 10 AND 11,ENSURING PROPER CLEARANCES Z o 18.GENERAL CONTRACTOR SHALL MAINTAIN ALL INSPECTION APPROVALS AND CORRECTION SHALL BE VERIFIED AS EXISTING AND FUNCTIONAL.ANY UPGRADES OR CHANGES SHALL FROM COMBUSTIBLES,REQUIRED HEARTH EXTENSIONS,AND USE OF LISTED AND m J NOTICES ON SITE AND PROVIDE COPIES TO THE HOMEOWNER&ENSURE ALL TRADES COMPLY WITH SUFFOLK COUNTY HEALTH DEPARTMENT AND LOCAL UTILITY AUTHORITY LABELED COMPONENTS. y W ARE PREPARED AND PRESENT FOR THEIR RESPECTIVE INSPECTIONS. STANDARDS. 8. EGRESS WINDOWS,DOORS,AND PATHWAYS SHALL MEET THE REQUIREMENTS OF SCOPE OF WORK: AS-BUILT DOCUMENTATION FOR EXISTING ONE-FAMILY RCNYS 2020:RESIDENTIAL CODE OF NEW YORK STATE x _ Q 18.AS-BUILT DRAWINGS SHALL CLEARLY DISTINGUISH BETWEEN EXISTING,REMOVED,AND RCNYS SECTION R310,PROVIDING SAFE AND UNOBSTRUCTED MEANS OF ESCAPE IN DWELLING RCNYS 2020:BUILDING CODE OF NEW YORK STATE y,� zx 19.ALL DIMENSIONS ARE TO THE FACE OF THE STUD UNO;4°WALLS REPRESENT 2X4 MODIFIED CONDITIONS USING STANDARD GRAPHIC CONVENTIONS.ALL DIMENSIONS, ALL SLEEPING ROOMS AND HABITABLE SPACES BELOW THE FOURTH STORY. ADDRESS 645 HAMILTON AVE,MATTITUCK,SOUTHOLD,NY 11952 MCNYS 2020:MECHANICAL CODE OF NEW YORK STATE cD FRAMING AND 6"WALLS REPRESENT 2X6 FRAMING. MATERIALS,AND CODE REFERENCES SHALL BE ACCURATE AND FIELD-CONFIRMED. 9. FIRE EXTINGUISHERS SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS IN PROPERTY TYPE ONE-FAMILY RESIDENCE(2 STOREY) PCNYS 2020:PLUMBING CODE OF NEW YORK STATE 20.DO NOT SCALE N.T.S DRAWINGS;WRITTEN DIMENSIONS TAKE PRECEDENCE OVER ANY ACCORDANCE WITH NFPA 10 RECOMMENDATIONS,TYPICALLY NEAR KITCHENS, OCCUPANCY GROUP R-3 NEC 2020:NATIONAL ELECTRICAL CODE(NFPA 70) 19.FINAL INSPECTIONS AND APPROVALS SHALL BE COORDINATED WITH THE TOWN OF SCALE FACTOR. SOUTHOLD BUILDING DEPARTMENT,INCLUDING STRUCTURAL,ELECTRICAL,PLUMBING, MECHANICAL ROOMS,AND GARAGES. CONSTRUCTION TYPE TYPE-VB FCNYS 2020:FIRE CODE OF NEW YORK STATE 21.IN CASE OF CONFLICTING INFORMATION,TECHNICAL NOTES SHALL TAKE PRECEDENCE MECHANICAL,AND FINAL CERTIFICATE OF OCCUPANCY INSPECTIONS. 10. ALL FIRE SAFETY DEVICES AND MATERIALS SHALL BE VERIFIED ON SITE FOR PROPER (APN) 1000140000200001000 EBNYS 2020:EXISTING BUILDING CODE OF NEW YORK STATE OVER THE DRAWINGS. INSTALLATION,OPERATION,AND LABELING PRIOR TO FINAL INSPECTION AND COUNTY SUFFOLK COUNTY TOWN OF SOUTHOLD ZONING REGULATIONS:LOCAL ZONING AND LAND USE APPROVAL BY THE TOWN OF SOUTHOLD BUILDING DEPARTMENT. ZONING WA REQUIREMENTS CLIMATE ZONE 4A(MIXED-HUMID) ARCHITECTURAL ABBREVIATIONS ARCHITECTURAL SYMBOLS STANDARD HATCHES SHEET INDEX DRAWING TILTE I SHEET DRAWING TITLE REVISION A.F.F ABOVE FINISHED FLOOR DIAG. DIAGONAL MFR. MANUFACTURER XXXXXX PAVERS G000 ARCHITECTURE COVER SHEET 00 A.S.0 ABOVE SUSPEND CEILING D.B.L DOUBLE MAT. MATERIAL ±00'-00" A.P ACOUSTICAL PLASTER MAX. MAXIMUM sow �,_ ,.,-„ CIVIL A.C.T ACOUSTICALTILE E.A EACH MIN. MINIMUM BLDG.LEVEL MARKER -:'U== ASPHALT PAVJSAND C001 (E)SITE PLAN 00 E.F EACH FACE MISC. MISCELLANEOUS BLDG.SEC.MARKER 77��y ARCHITECTURE B/S BOTH SIDES ELEV. ELEVATION M.H MANHOLE Q Yh4o ROOFING A001 (E)BASEMENT FLOOR PLAN 00 Fs i B/W BOTH WAYS EQ. EQUAL M.S MUD SILL A002 (E)GROUND FLOOR PLAN 00sow -- ---- B.W BETWEEN EQUPT. EQUIPMENT WOOD/LUMBER A003 a � � (E)FIRST FLOOR PLAN 00 B.T.P BOTTOM PLATE EXP. EXPOSED (N) NEW FTG.SECTION MARKER A004 (E)ROOF LAYOUT PLAN 00 L'` BLDG. BUILDING EXT. EXTERIOR N.T.S NOT TO SCALE GRID LINES MARKER -=��� CONCRETE A005 (E)FRONT ELEVATION EL-01 00 B.L BOUNDARY LINE -"-- - F.X FIXED O/C ON CENTER 4�_ ----- A006 (E)SIDE ELEVATION EL-02 CLG. CEILING F.LB FIBER GLASS INSULATION �^ 1� : _:::. LANDSCAPE A007 (E)REAR ELEVATION EL-03 DD CLIENT: HOME OWNER CLG.HT CEILING HEIGHT FIN. FINISH PRJ(P) PROPOSED a, ,1 A008 (E)SIDE ELEVATION EL-04 00 DRAFTSMAN: A.H CLR. CLEAR F.A FIRE ALARM PR. PLYWOOD BLDG.ELEV.MARKER l��f� EX./PR.BUILDING CSMNT. CASEMENT F.E FIRE EXTINGUISHER Pi PROPERTY LINE z _ REVIEWER: E.Z.H.B CAB. CABINET F.E.0 FIRE EXTINGUISHER CABINET PAN. PANTRY DETAIL CALLOUT STONE PAV. C.T CERAMIC TILE F.T FLOOR TRAP PROJECT ID: 511 CL. CLOSET F.S.B.L FRONT SETBACK LINE REF. REFRIGERATOR BLDG.ELEV.MARKER _ p _ SIDING - DRAWING: S-ZG-(6-511 R.S.B.L REAR SETBACK LINE T DET. DETAIL GYP.BRD GYPSUM BOARD HNG. RANGE EARTH - DATE: 28.10.20 5 DIA. DIAMETER GC GENERAL CONTRACTOR 'O' TAGS DOC REF: AS B D.H DOUBLE HUNG S.H SINGLE HUNG / CMU BLOCKS IX./(E) EXISTING INT. INTERIOR SLOG. SLIDING INT.ELEV.MARKER a - D/W DISHWASHER SPECS. SPECIFICATIONS E -- - D/R DRYER L.V.P LUXURY VINYL PLANK STRD. STANDARDS BRICK DEMO. DEMOLISH LAV. LAVATORY SUSP. SUSPENDED / s � OOO DET. DETAIL LAB. LABORATORY S.0 SHOWER CABIN STAIR DIRECTION ARROW NORTH DIRECTION ARROW CX xzxxx }� INSULATION -- CIVIL NOTES 1. 1963 SURVEY REMAINS THE OFFICIAL RECORD ON FILE WITH THE TOWN OF SOUTHOLD. 2. ALL CIVIL AND SITE WORK SHALL COMPLY WITH THE RESIDENTIAL CODE OF NEW YORK STAMP STATE(RCNYS 2020),BUILDING CODE OF NEW YORK STATE(BCNYS 2020),AND THE TOWN OF SOUTHOLD ZONING CODE (§280), INCLUDING SUFFOLK COUNTY STORMWATER AND GRADING REGULATIONS. OF NpW ro 3. THE AS-BUILT SITE PLAN SHALL SHOW PROPERTY LINES,STRUCTURE FOOTPRINT, *S SETBACKS, EASEMENTS, DRIVEWAY, WALKWAYS, DRAINAGE, AND ALL EXISTING ° UTILITIES AS VERIFIED BY FIELD MEASUREMENT. f o 0 4. FINAL GRADING AROUND THE BUILDING SHALL SLOPE A MINIMUM OF 5%AWAY FROM THE FOUNDATION FOR THE FIRST 10 FEET IN COMPLIANCE WITH RCNYS SECTION ° 102705 V R401.3,TO PREVENT WATER ACCUMULATION AT THE FOUNDATION. °°ESS%oaP 5. STORMWATER MANAGEMENT SYSTEMS,INCLUDING DRYWELLS,CATCH BASINS,AND 11/7/2025 SWALES,SHALL BE INSTALLED AND MAINTAINED PER SUFFOLK COUNTY AND TOWN OF REVISION LOG SOUTHOLD REQUIREMENTS,WITH LOCATIONS VERIFIED IN THE FIELD. 6. WATER SUPPLY AND SANITARY SYSTEMS SHALL CONFORM TO THE NEW YORK STATE NO. REVISION PLUMBING CODE(NYSPC)AND SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES (SCDHS)REGULATIONS,INCLUDING VERIFIED TANK AND LEACH FIELD LOCATIONS. ° 7. ALL UNDERGROUND ELECTRICAL AND COMMUNICATION CONDUITS SHALL BE INSTALLED PER NEC 2020 MINIMUM BURIAL DEPTHS AND IDENTIFIED ON THE AS-BUILT DRAWINGS. 8. RETAINING WALLS,STEPS,OR GRADE CHANGES OVER 4 FEET IN HEIGHT SHALL BE R35 —4LUDNGPROPERVERIFIED FOR STUCTURAL ILITY AND BUILT DRAI DRAINAGE BEHIND WITH RCNYS 2 SECTION1807,NC „ 9. ALL SITE ELEVATIONS SHALL BE BASED ON APPROVED SURVEY BENCHMARKS AND R 81 -9 REPORTED IN NORTH AMERICAN VERTICAL DATUM (NAVD 88). THE LICENSED SURVEYOR SHALL CERTIFY FINAL ELEVATIONS AND LOT DRAINAGE. 10.ANY WORK LOCATED IN FLOOD HAZARD OR COASTAL ZONES SHALL COMPLY WITH THE TOWN OF SOUTHOLD FLOOD DAMAGE PREVENTION ORDINANCE(§275)AND FEMA BASE FLOOD ELEVATION REQUIREMENTS. v4 11.ALL SITE IMPROVEMENTS, INCLUDING GRADING, DRAINAGE, AND LANDSCAPING, O ,n SHALL BE COMPLETED AND VERIFIED PRIOR TO FINAL INSPECTION AND CERTIFICATE v OF OCCUPANCY APPROVAL BY THE TOWN OF SOUTHOLD BUILDING DEPARTMENT. rn j O LEGAL INFORMATION � J z O I SITE ADDRESS: 645 HAMILTON AVE,MATTITUCK,SOUTHOLD,NY LLJ J\ 11952 �j = V LOT NO.: 2 - - -.°-` LOT AREA: 0.38ACR ', o y 7 ASSESSOR'S PARCEL NUMBER: 1000140000200001000 J / ZONING DESIGNATION: N/A Lu CDh.' _ LPL AREA STATEMENT ...:-.•.•-•. ' Ld -------------------------------- O Z � 1133 SO.FT LOT 0 •...-: . OAF q7��c o PRINCIPLE BUILDING BUILT UP AREA 1 • ACCESSORY STRUCTURES BUILT UP AREA 167 SO.Ff -- - - 048 s ' PARKING AREA 3 SQ.FT a: .<</ y -`-•-`,•,•_`,` %PERVIOUS AREA ------------------------------------------------------- 73.1 co • - - "�`, '. %IMPERVIOUS AREA --------------------- 182 .i y XLLJ = C/r. SITE PLAN LEGEND 0V - PROPERTY LINE G.L GAS LINE �' e• s.^ �� . DRAWINGTILTE oIELL(;UMMUNIL;AIIUN LINE _X_X -------T240------- WA ILK MTRRAGFF[OW OM.H MANHOLE ® BOLLARD (E)SITE PLAN •4;:::( •'' : � j ` w.M WATER METER LIGHT POLE LOT 6520 \ ':' ? �� E M ENERGY METER UTILITY POLE GAS METER �H FIRE HYDRANT WATER VALVE TREE CLIENT: HOMEOWNER c.v GAS VALVE °os DOWNSPOUT DRAFTSMAN: A.H REVIEWER: E.Z.H.B CONCRETE PAVERS PROJECT ID: 511 0 •'•'••'''''''•- LANDSCAPE ASPHALT PAV. DRAWING: MS-ZG-06-511 BUILDING ROOFING DATE: 28.1o.2oz5 DOC REF: AS-BUILT STONE PAV. / WOOD/LUMBER r c 001 a I ARCHITECTURAL NOTES \ 1. ALL ARCHITECTURAL WORK SHALL COMPLY WITH THE RESIDENTIAL CODE OF NEW YORK STATE(RCNYS 2020),BUILDING CODE OF NEW YORK STATE(BCNYS 2020), STAMP ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE(ECCCNYS 2020), AND THE TOWN OF SOUTHOLD ZONING CODE(§280). 2. ALL EXISTING CONDITIONS,DIMENSIONS,AND MATERIALS SHALL BE FIELD-VERIFIED or NEW y PRIOR TO PREPARATION OF FINAL AS-BUILT DRAWINGS. ANY VARIATION FROM y<PppaY'Hp��sop� EL-3 APPROVED PLANS SHALL BE DOCUMENTED AND SUBMITTED TO THE BUILDING A007 DEPARTMENT. e 3. ALL FLOOR PLANS,ELEVATIONS,SECTIONS,AND DETAILS SHALL REPRESENT TRUE o AS-BUILT CONDITIONS,INCLUDING STRUCTURAL MEMBERS,PARTITIONS,OPENINGS, pnu� CEILING HEIGHTS,AND FINISHES. oFEssloNP` 4. ALL MATERIALS AND CONSTRUCTION DETAILS SHALL CONFORM TO RCNYS CHAPTER 3 11/7/2025 FOR BUILDING PLANNING AND CHAPTER 7 FOR WALL COVERINGS AND INTERIOR 26' FINISHES. REVISION LOG 5. ALL INTERIOR FINISH MATERIALS SHALL COMPLY WITH FLAME-SPREAD AND NO. REVISION SMOKE-DEVELOPED INDEX REQUIREMENTS OF RCNYS TABLE R302.9. _ 6. MINIMUM ROOM DIMENSIONS, CEILING HEIGHTS, AND HABITABLE SPACE OIL TANK WATER PUMP _ REQUIREMENTS SHALL CONFORM TO RCNYS SECTIONS R304 AND R305. 7. ALL DOORS,WINDOWS,AND SKYLIGHTS SHALL BE NFRC-LABELED AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND CODE-APPROVED FLASHING AND WEATHER-RESISTANT BARRIERS PER RCNYS R609 AND R703. 8. STAIRS,HANDRAILS,AND GUARDS SHALL COMPLY WITH RCNYS R311 AND R312 FOR RISE,RUN,WIDTH,AND GUARD HEIGHT REQUIREMENTS. 9. FIRE-SEPARATION REQUIREMENTS BETWEEN GARAGES,DWELLING UNITS,AND ATTICS SHALL COMPLY WITH RCNYS R302, INCLUDING FIRE-RATED ASSEMBLIES AND PROTECTED OPENINGS. = 10.SMOKE ALARMS AND CARBON MONOXIDE DETECTORS SHALL BE INSTALLED AS REQUIRED BY RCNYS R314 AND R315 AND SHALL BE HARD-WIRED WITH BATTERY pOBACKUP AND INTERCONNECTION WHERE REQUIRED. 0 OO ® 11.THERMAL ENVELOPE ELEMENTS(INSULATION,AIR BARRIER,AND VAPOR RETARDER) BASEMENT HALL SHALL BE DOCUMENTED AND VERIFIED TO MEET ECCCNYS R402 MINIMUM HOT WATER 2540120'-01° PERFORMANCE VALUES FOR CLIMATE ZONE 4. HEATER CLG.08'-00" 12.ALL ATTIC AND CRAWL SPACE VENTILATION SHALL COMPLY WITH RCNYS R806 AND � R408 TO ENSURE ADEQUATE AIR CIRCULATION AND MOISTURE CONTROL. rn 13.ALL ARCHITECTURAL OPENINGS A006 A0 8 ILL BESEA ED TOF MAINTAIN CTHE CONTINUITY IOF FIRE,NAIR,HAND MOISTURE BARRIERS. J z J FURNACE 14.ACCESSIBILITY FEATURES,WHERE APPLICABLE,SHALL CONFORM TO BCNYS 2020 LJJ 0 SECTION 1107 FOR RESIDENTIAL USE AND UNIVERSAL DESIGN ELEMENTS, _ RECOGNIZING THAT SINGLE-FAMILY HOMES ARE GENERALLY EXEMPT FROM ADA ~ C3 REQUIREMENTS, O 15.ALL EXTERIOR ELEVATIONS SHALL SHOW FINISHED GRADE LINES,ROOF HEIGHTS,AND Z J MATERIAL TRANSITIONS IN COMPLIANCE WITH TOWN OF SOUTHOLD HEIGHT AND W U SETBACK REGULATIONS. 16.MECHANICAL, ELECTRICAL, AND PLUMBING FIXTURE LOCATIONS SHALL BE LaL COORDINATED WITH ARCHITECTURAL DRAWINGS AND FIELD-VERIFIED FOR AS-BUILT V ACCURACY. Lu 17.ENERGY EFFICIENT LIGHTING AND APPLIANCES SHALL COMPLY WITH NEC 2020 AND Z w ECCCNYS ELECTRICAL EFFICIENCY REQUIREMENTS. J 18.ATTIC ACCESS AND CRAWL SPACE ACCESS OPENINGS SHALL BE PROVIDED IN cp CRAWL SPACE CRAWL SPACE ACCORDANCE WITH RCNYS R807 AND B408 AND SHALL BE CLEARLY DOCUMENTED ON = Z o = 12'-04"X03'-03" 12'-04"X03'-03" = m - CLG.08'-00" CLG.08'-00" - - AS-BUILT DRAWINGS. y 19.ALL ARCHITECTURAL WORK AND FIELD MODIFICATIONS SHALL BE SUBJECT TO FINAL y INSPECTION AND APPROVAL BY THE TOWN OF SOUTHOLD BUILDING DEPARTMENT Q X PRIOR TO ISSUANCE OF CERTIFICATE OF OCCUPANCY. N.1 - 26 DRAWING TILTE EL-1 A005 (E)BASEMENT FLOOR PLAN CLIENT: HOME OWNER DRAFTSMAN: A.H REVIEWER: E.Z.H.B PROJECTID: 511 BASEMENT PLAN DRAWING: MS-ZG-06-511 FP-01 SCALE:3/8"=1'-O" DATE: 28.10.2025 DOC REF: AS-BUILT a A001 ARCHITECTURAL NOTES EL-3 ` 1. ALL ARCHITECTURAL WORK SHALL COMPLY WITH THE RESIDENTIAL CODE OF NEW A007 YORK STATE(RCNYS 2020),BUILDING CODE OF NEW YORK STATE(BCNYS 2020), STAMP ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE(ECCCNYS 2020), AND THE TOWN OF SOUTHOLD ZONING CODE(§280). 2. ALL EXISTING CONDITIONS,DIMENSIONS,AND MATERIALS SHALL BE FIELD-VERIFIED P�EOF NEW Yo 35 PRIOR TO PREPARATION OF FINAL AS-BUILT DRAWINGS. ANY VARIATION FROM a�ooPv�"OFsR�r APPROVED PLANS SHALL BE DOCUMENTED AND SUBMITTED TO THE BUILDING 9' 10'-4° 12' ,�3'-8" DEPARTMENT. 2'-6" T 3. ALL FLOOR PLANS,ELEVATIONS,SECTIONS,AND DETAILS SHALL REPRESENT TRUE m 6'-7" 4'-10" ?� AS-BUILT CONDITIONS,INCLUDING STRUCTURAL MEMBERS,PARTITIONS,OPENINGS, CEILING HEIGHTS,AND FINISHES. oFEsstoNP` 4. ALL MATERIALS AND CONSTRUCTION DETAILS SHALL CONFORM TO RCNYS CHAPTER 3 11/7/2025 FOR BUILDING PLANNING AND CHAPTER 7 FOR WALL COVERINGS AND INTERIOR FINISHES. REVISION LOG \ 5. ALL INTERIOR FINISH MATERIALS SHALL COMPLY WITH FLAME-SPREAD AND NO. REVISION SMOKE-DEVELOPED INDEX REQUIREMENTS OF RCNYS TABLE R302.9. 6. MINIMUM ROOM DIMENSIONS, CEILING HEIGHTS, AND HABITABLE SPACE REQUIREMENTS SHALL CONFORM TO RCNYS SECTIONS R304 AND R305. 7. ALL DOORS,WINDOWS,AND SKYLIGHTS SHALL BE NFRC-LABELED AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND CODE-APPROVED FLASHING AND WEATHER-RESISTANT BARRIERS PER RCNYS R609 AND R703. 8. STAIRS,HANDRAILS,AND GUARDS SHALL COMPLY WITH RCNYS R311 AND R312 FOR CLOSET RISE,RUN,WIDTH,AND GUARD HEIGHT REQUIREMENTS. BEDROOM 01 9. FIRE-SEPARATION REQUIREMENTS BETWEEN GARAGES,DWELLING UNITS,AND ATTICS 10'-00"X10'-04" SHALL COMPLY WITH RCNYS R302, INCLUDING FIRE-RATED ASSEMBLIES AND CLG.09'-00" PROTECTED OPENINGS. 10.SMOKE ALARMS AND CARBON MONOXIDE DETECTORS SHALL BE INSTALLED AS ® _ REQUIRED BY RCNYS R314 AND R315 AND SHALL BE HARD-WIRED WITH BATTERY BACKUP AND INTERCONNECTION WHERE REQUIRED. TVIPLAYROOM LIVING ROOM 11.THERMAL ENVELOPE ELEMENTS(INSULATION,AIR BARRIER,AND VAPOR RETARDER) OT-08"XIT-00" �� 11'-08"X16'-08" SHALL BE DOCUMENTED AND VERIFIED TO MEET ECCCNYS R402 MINIMUM CLG.0940" / CLG.OT-00" PERFORMANCE VALUES FOR CLIMATE ZONE 4. i 7p 12.ALL ATTIC AND CRAWL SPACE VENTILATION SHALL COMPLY WITH RCNYS R806 AND N R408 TO ENSURE ADEQUATE AIR CIRCULATION AND MOISTURE CONTROL. (m rn ® 13.ALL ARCHITECTURAL OPENINGS FOR ELECTRICAL, PLUMBING, AND HVAC Z } PENETRATIONS SHALL BE SEALED TO MAINTAIN THE CONTINUITY OF FIRE,AIR,AND LL J z STORAGE MOISTURE BARRIERS. Z J 0 10'-00"XO6'-06" 14.ACCESSIBILITY FEATURES,WHERE APPLICABLE,SHALL CONFORM TO BCNYS 2020 W Jo SECTION 1107 FOR RESIDENTIAL USE AND UNIVERSAL DESIGN ELEMENTS, _ CLG.09'-00" _ RECOGNIZING THAT SINGLE-FAMILY HOMES ARE GENERALLY EXEMPT FROM ADA C ZD %/ REQUIREMENTS. ?, c:) 15.ALL EXTERIOR ELEVATIONS SHALL SHOW FINISHED GRADE LINES,ROOF HEIGHTS,AND Z J / MATERIAL TRANSITIONS IN COMPLIANCE WITH TOWN OF SOUTHOLD HEIGHT AND LCJJ U eEL-2 EL-4 SETBACK REGULATIONS. G o _ e 16.MECHANICAL, ELECTRICAL, AND PLUMBING FIXTURE LOCATIONS SHALL BE = LaL A006 A008 COORDINATED WITH ARCHITECTURAL DRAWINGS AND FIELD-VERIFIED FOR AS-BUILT O LiJ ACCURACY. O Ld 17.ENERGY EFFICIENT LIGHTING AND APPLIANCES SHALL COMPLY WITH NEC 2020 AND � BATH HOME OFFICE ECCCNYS ELECTRICAL EFFICIENCY REQUIREMENTS. 04'48"X06'-06" 10'-09"XOT-00" J cm zo 18.ATTIC ACCESS AND CRAWL SPACE ACCESS OPENINGS SHALL BE PROVIDED IN CLG.09'-00" ! CLG.09'-00° = Z F- ACCORDANCE WITH RCNYS R807 AND R408 AND SHALL BE CLEARLY DOCUMENTED ON / = AS-BUILT DRAWINGS. m y :,=i 19.ALL ARCHITECTURAL WORK AND FIELD MODIFICATIONS SHALL BE SUBJECT TO FINAL y _ INSPECTION AND APPROVAL BY THE TOWN OF SOUTHOLD BUILDING DEPARTMENT a W Lo _ PRIOR TO ISSUANCE OF CERTIFICATE OF OCCUPANCY. MUOROOM / 1 V-07"XO4'-11" - CLG.09'-00" DRAWING TILTE RO T,DEC = i (E)GROUND FLOOR PLAN 4, 6'-3° 8'-4" T-11" 12'-6° 35' CLIENT: HOME OWNER DRAFTSMAN: A.H REVIEWER: E.Z.H.B EL-1 PROJECT ID: 511 GROUND FLOOR PLAN A005 DRAWING: MS-ZG-06-511 FP-02 SCALE:3/8"=1'-W DATE: 28.10.2025 DOC REF: AS-BUILT a A002 ARCHITECTURAL NOTES \ 1. ALL ARCHITECTURAL WORK SHALL COMPLY WITH THE RESIDENTIAL CODE OF NEW YORK STATE(RCNYS 2020),BUILDING CODE OF NEW YORK STATE(BCNYS 2020), ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE(ECCCNYS 2020). STAMP AND THE TOWN OF SOUTHOLD ZONING CODE(§280). 2. ALL EXISTING CONDITIONS,DIMENSIONS,AND MATERIALS SHALL BE FIELD-VERIFIED (EOF NEW yo PRIOR TO PREPARATION OF FINAL AS-BUILT DRAWINGS. ANY VARIATION FROM S�P�oPYJNO`" Rf EL-3 APPROVED PLANS SHALL BE DOCUMENTED AND SUBMITTED TO THE BUILDING A007 DEPARTMENT. 3. ALL FLOOR PLANS,ELEVATIONS,SECTIONS,AND DETAILS SHALL REPRESENT TRUE " o` AS-BUILT CONDITIONS,INCLUDING STRUCTURAL MEMBERS,PARTITIONS,OPENINGS, CEILING HEIGHTS,AND FINISHES. FEss10NP 4. ALL MATERIALS AND CONSTRUCTION DETAILS SHALL CONFORM TO RCNYS CHAPTER 3 11/7/2025 FOR BUILDING PLANNING AND CHAPTER 7 FOR WALL COVERINGS AND INTERIOR 26 FINISHES. REVISION LOG 5. ALL INTERIOR FINISH MATERIALS SHALL COMPLY WITH FLAME-SPREAD AND NO. REVISION SMOKE- NDEX CNYS 81 73543'-8" MINIMUDEVROPEDIDIMESIONS, CEILING HEIGHTS, AND 6. MINIMUM ROOM DIMENSIONS, CEILING HEIGHTS, AND HABITABLE SPACE REQUIREMENTS SHALL CONFORM TO RCNYS SECTIONS B304 AND R305. 7. ALL DOORS,WINDOWS,AND SKYLIGHTS SHALL BE NFRC-LABELED AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND CODE-APPROVED FLASHING AND WEATHER-RESISTANT BARRIERS PER RCNYS R609 AND R703. / CLOSET B. STAIRS,HANDRAILS,AND GUARDS SHALL COMPLY WITH RCNYS R311 AND R312 FOR RISE,RUN,WIDTH,AND GUARD HEIGHT REQUIREMENTS. 9. FIRE-SEPARATION REQUIREMENTS BETWEEN GARAGES,DWELLING UNITS,AND ATTICS SHALL COMPLY WITH RCNYS R302, INCLUDING FIRE-RATED ASSEMBLIES AND BEDROOM 03 PROTECTED OPENINGS. 134611045" 10.SMOKE ALARMS AND CARBON MONOXIDE DETECTORS SHALL BE INSTALLED AS CLG.09'-00" REQUIRED BY RCNYS R314 AND R315 AND SHALL BE HARD-WIRED WITH BATTERY BACKUP AND INTERCONNECTION WHERE REQUIRED. 11.THERMAL ENVELOPE ELEMENTS(INSULATION,AIR BARRIER,AND VAPOR RETARDER) SHALL BE DOCUMENTED AND VERIFIED TO MEET ECCCNYS R402 MINIMUM PERFORMANCE VALUES FOR CLIMATE ZONE 4. DINING/FAMILY ROOM % 12.ALL ATTIC AND CRAWL SPACE VENTILATION SHALL COMPLY WITH RCNYS R806 AND N 08'-02"XI842" R408 TO ENSURE ADEQUATE AIR CIRCULATION AND MOISTURE CONTROL. (z rn CLG.09'-00" ! 13.ALL ARCHITECTURAL OPENINGS FOR ELECTRICAL, PLUMBING, AND HVAC Z T PENETRATIONS SHALL BE SEALED TO MAINTAIN THE CONTINUITY OF FIRE,AIR,AND LL J z MOISTURE BARRIERS. Z J EL-2 m 30"WIOE HALLWAY o0 0 _ EL-4 O W OJ 14.ACCESSIBILITY FEATURES,WHERE APPLICABLE,SHALL CONFORM TO RCNYS 2020 A006 Q AO08 SECTION 1107 FOR RESIDENTIAL USE AND UNIVERSAL DESIGN ELEMENTS, _ RECOGNIZING THAT SINGLE-FAMILY HOMES ARE GENERALLY EXEMPT FROM ADA a G = ! REQUIREMENTS. y,CD 15.ALL EXTERIOR ELEVATIONS SHALL SHOW FINISHED GRADE LINES,ROOF HEIGHTS,AND Z J Y MATERIAL TRANSITIONS IN COMPLIANCE WITH TOWN OF SOUTHOLD HEIGHT AND W v SETBACK REGULATIONS. Q 16.MECHANICAL, ELECTRICAL, AND PLUMBING FIXTURE LOCATIONS SHALL BE 6L BEDROOM 02 COORDINATED WITH ARCHITECTURAL DRAWINGS AND FIELD-VERIFIED FOR AS-BUILT O L a "c 09'-01'X10'-05" ACCURACY. In Z w CLG.09'-00" 17.ENERGY EFFICIENT LIGHTING AND APPLIANCES SHALL COMPLY WITH NEC 2020 AND 0 Lu IIIrU �� ECCCNYS ELECTRICAL EFFICIENCY REQUIREMENTS. J cmz UU KITCHEN BATH 18.ATTIC ACCESS AND CRAWL SPACE ACCESS OPENINGS SHALL BE PROVIDED IN = z CD _ (3 09'-09'XO5'-06" 05'-10'X70'-05" - ACCORDANCE WITH RCNYS R807 AND R408 AND SHALL BE CLEARLY DOCUMENTED ON co CLG. CLG.09'-00" AS-BUILT DRAWINGS. 19.ALL ARCHITECTURAL WORK AND FIELD MODIFICATIONS SHALL BE SUBJECT TO FINAL 06 y = CLOSET / INSPECTION AND APPROVAL BY THE TOWN OF SOUTHOLD BUILDING DEPARTMENT Q W o / PRIOR TO ISSUANCE OF CERTIFICATE OF OCCUPANCY. i 5_2" T-7Z, 7, 10'-5" -2" 2'4" 7'-1" DRAWING TILTE 26' EL-1 A005 (E)FIRST FLOOR PLAN CLIENT: HOME OWNER DRAFTSMAN: A.H REVIEWER: E.Z.H.B PROJECTID: 511 FIRST FLOOR PLAN DRAWING: MS-ZG-06-511 FP-03 SCALE:3/8"=1'-O" DATE: 28.10.2025 DOC REF: AS-BUILT a A003 ARCHITECTURAL NOTES \ 1. ROOFING MATERIALS SHALL COMPLY WITH THE RESIDENTIAL CODE OF NEW YORK EL-3 STATE(RCNYS 2020) SECTION R905, ENSURING APPROVED WEATHER-RESISTANT A007 COVERINGS AND PROPER UNDERLAYMENT INSTALLATION. STAMP 2. AN ICE BARRIER SHALL BE INSTALLED AS REQUIRED BY RCNYS SECTION R905.1.2 IN AREAS SUBJECT TO SNOW OR ICE,EXTENDING FROM THE EAVE TO AT LEAST 24 OF NE{y Yoq INCHES INSIDE THE EXTERIOR WALL LINE.ALL ROOF SLOPES SHALL BE VERIFIED TO ytP4oav xoy�s f MEET CODE-MINIMUM REQUIREMENTS FOR DRAINAGE. 3. ALL EXISTING CONDITIONS,DIMENSIONS,AND MATERIALS SHALL BE FIELD-VERIFIED n e 9 29 PRIOR TO PREPARATION OF FINAL AS-BUILT DRAWINGS. ANY VARIATION FROM m APPROVED PLANS SHALL BE DOCUMENTED AND SUBMITTED TO THE BUILDING 1'-6° 7'-6" 1'-6" 18'-8" 5- 2'4" 1'-6" DEPARTMENT. ROFEssl 11 4. ALL FLOOR PLANS,ELEVATIONS,SECTIONS,AND DETAILS SHALL REPRESENT TRUE >>/�/zozs AS-BUILT CONDITIONS,INCLUDING STRUCTURAL MEMBERS,PARTITIONS,OPENINGS, CEILING HEIGHTS,AND FINISHES. REVISION LOG 5. ALL MATERIALS AND CONSTRUCTION DETAILS SHALL CONFORM TO RCNYS CHAPTER 3 NO. REVISION r FOR BUILDING PLANNING AND CHAPTER 7 FOR WALL COVERINGS AND INTERIOR I` FINISHES. it 6. ALL INTERIOR FINISH MATERIALS SHALL COMPLY WITH FLAME-SPREAD AND SMOKE-DEVELOPED INDEX REQUIREMENTS OF RCNYS TABLE R302.9. 7. MINIMUM ROOM DIMENSIONS, CEILING HEIGHTS, AND HABITABLE SPACE REQUIREMENTS SHALL CONFORM TO RCNYS SECTIONS R304 AND R305. 8. ALL DOORS,WINDOWS,AND SKYLIGHTS SHALL BE NFRC-LABELED AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND CODE-APPROVED FLASHING AND WEATHER-RESISTANT BARRIERS PER RCNYS R609 AND R703. 9. STAIRS,HANDRAILS,AND GUARDS SHALL COMPLY WITH RCNYS R311 AND R312 FOR RISE,RUN,WIDTH,AND GUARD HEIGHT REQUIREMENTS. 10.FIRE-SEPARATION REQUIREMENTS BETWEEN GARAGES,DWELLING UNITS,AND ATTICS ff Q SHALL COMPLY WITH RCNYS R302, INCLUDING FIRE-RATED ASSEMBLIES AND PROTECTED OPENINGS. 11.SMOKE ALARMS AND CARBON MONOXIDE DETECTORS SHALL BE INSTALLED AS REQUIRED BY RCNYS R314 AND R315 AND SHALL BE HARD-WIRED WITH BATTERY BACKUP AND INTERCONNECTION WHERE REQUIRED. 12.THERMAL ENVELOPE ELEMENTS(INSULATION,AIR BARRIER,AND VAPOR RETARDER) ,N SHALL BE DOCUMENTED AND VERIFIED TO MEET ECCCNYS R402 MINIMUM (f rn PERFORMANCE VALUES FOR CLIMATEZONE 4. Z r 13.ALL ATTIC AND CRAWL SPACE VENTILATION SHALL COMPLY WITH RCNYS R806 AND LL J z R408 TO ENSURE ADEQUATE AIR CIRCULATION AND MOISTURE CONTROL. Z J o 14.ALL ARCHITECTURAL OPENINGS FOR ELECTRICAL, PLUMBING, AND HVAC LJJ f o PENETRATIONS SHALL BE SEALED TO MAINTAIN THE CONTINUITY OF FIRE,AIR,AND _ MOISTURE BARRIERS. I-- G 15.ACCESSIBILITY FEATURES,WHERE APPLICABLE,SHALL CONFORM TO BCNYS 2020 H EL-2 EL-4 SECTION 1107 FOR RESIDENTIAL USE AND UNIVERSAL DESIGN ELEMENTS, Z J Y A006 A008 RECOGNIZING THAT SINGLE-FAMILY HOMES ARE GENERALLY EXEMPT FROM ADA LJ.1 v I it I illyREQUIREMENTS. ZD 16.ALL EXTERIOR ELEVATIONS SHALL SHOW FINISHED GRADE LINES,HOOF HEIGHTS,AND LPL MATERIAL TRANSITIONS IN COMPLIANCE WITH TOWN OF SOUTHOLD HEIGHT AND O I.LJ SETBACK REGULATIONS. 17.MECHANICAL, ELECTRICAL, AND PLUMBING FIXTURE LOCATIONS SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS AND FIELD-VERIFIED FOR AS-BUILT J_ ('3 z ACCURACY. 18.ENERGY EFFICIENT LIGHTING AND APPLIANCES SHALL COMPLY WITH NEC 2020 AND = Z CD ECCCNYS ELECTRICAL EFFICIENCY REQUIREMENTS. m 19.ATTIC ACCESS AND CRAWL SPACE ACCESS OPENINGS SHALL BE PROVIDED IN Q _ ACCORDANCE WITH RCNYS R807 AND R408 AND SHALL BE CLEARLY DOCUMENTED ON LJJ ,n AS-BUILT DRAWINGS. 20.ALL ARCHITECTURAL WORK AND FIELD MODIFICATIONS SHALL BE SUBJECT TO FINAL INSPECTION AND APPROVAL BY THE TOWN OF SOUTHOLD BUILDING DEPARTMENT PRIOR TO ISSUANCE OF CERTIFICATE OF OCCUPANCY. DRAWING TILTE (E)ROOF PLAN T-6° 1' 1'-6° 12'-3° 1'-6" 1V-3" 1'-6" 38' CLIENT: HOME OWNER DRAFTSMAN: A.H REVIEWER: E.Z.H.B ROOF PLAN EL-, PROJECT ID: 511 A005 DRAWING: Ms-zc-06-511 RP-04 SCALE:3/8"=1'-O" DATE: 28.10.2025 DOC REF: AS-BUILT A004 ELEVATION NOTES 1. ALL EXTERIOR ELEVATIONS SHALL REPRESENT TRUE AS-BUILT CONDITIONS, INCLUDING FINISHED GRADES,ROOF HEIGHTS,WINDOW AND DOOR LOCATIONS,AND STAMP MATERIAL TRANSITIONS. 2. EXTERIOR WALL CONSTRUCTION,CLADDING,AND WEATHER BARRIERS SHALL COMPLY WITH RCNYS SECTIONS R703 AND R704 FOR WEATHER RESISTANCE, WATER (E OF NEIV, MANAGEMENT,AND MATERIAL INSTALLATION. *yt 40 MO(�F3 3. FINISHED GRADE ELEVATIONS SHALL BE SHOWN AND SHALL MATCH VERIFIED FIELD SURVEY DATA. ALL GRADES SHALL SLOPE AWAY FROM THE FOUNDATION AS REQUIRED BY RCNYS SECTION R401.3. 4. MAXIMUM BUILDING HEIGHT SHALL CONFORM TO THE TOWN OF SOUTHOLD ZONING o 110210S CODE(§280),AND SHALL BE VERIFIED FROM AVERAGE GRADE TO THE HIGHEST POINT ROFEssl OF THE ROOF. 11/7/2025 5. ALL ROOF ASSEMBLIES SHALL COMPLY WITH RCNYS CHAPTER 9 FOR MATERIALS, REVISION LOG INSTALLATION,AND DRAINAGE REQUIREMENTS.ROOF PITCH AND DRAINAGE SLOPES SHALL BE CLEARLY INDICATED. NO. REVISION TO_'LEVEL------------------------- 6. EXTERIOR DOORS, WINDOWS, AND SKYLIGHTS SHALL BE NFRC-LABELED AND +21'-O6 ' INSTALLED WITH CODE-APPROVED FLASHING,SEALANTS,AND WEATHER-RESISTANT OPENING DETAILS PER RCNYS R609 AND R703. 7. EXTERIOR MATERIALS(SIDING,TRIM,MASONRY,STUCCO,OR PANEL SYSTEMS)SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER REQUIREMENTS AND RCNYS TABLE R703.4 FOR FASTENING AND SUPPORT. 8. ALL EAVES, SOFFITS, AND FASCIA SHALL BE CONSTRUCTED WITH APPROVED CEILING JOIST_TOP MATERIALS AND PROPER VENTILATION WHERE REQUIRED PER RCNYS SECTION R806. Y+21'-06" 9. ROOF AND WALL PENETRATIONS(VENTS,FLUES,EXHAUST TERMINALS,ELECTRICAL MASTS)SHALL BE WEATHER-SEALED AND LOCATED AS SHOWN ON ELEVATIONS; SEPARATIONS FROM OPENINGS SHALL COMPLY WITH RCNYS MECHANICAL REQUIREMENTS. 10.GUTTERS, DOWNSPOUTS,AND ROOF DRAINAGE COMPONENTS SHALL DISCHARGE AWAY FROM THE FOUNDATION TO APPROVED DRAINAGE AREAS OR DRYWELLS AS SHOWN ON THE SITE PLAN. 11.ALL ELEVATION MATERIALS AND FINISHES SHALL MATCH FIELD-CONFIRMED CONDITIONS AND BE DOCUMENTED IN THE AS-BUILT DRAWINGS,INCLUDING COLOR, TEXTURE,AND MATERIAL TYPE. N Lo � � r LL J Z FIRST FLOOR F.F.E W J O ———————————————————————— Q U 0 W Y C U G � � u- O W � ® _J L] HH � O¢ ' Co z - - ULIL z oD m H COD GROUND FLOOR F.F.E m Lu cD T ofmv---- wl T DRAWING TILTE BASEMENT A 00-- F.F.E — ---------------- — ai LK n �? <��r X `� a R 'f?ia ✓ 'z ar` rF '�`t9� ws' r - 3 (E)FRONT ELEVATION EL-01 CLIENT: HOME OWNER DRAFTSMAN: A.H REVIEWER: E.Z.H.B PROJECTID: 511 FRONT ELEVATION DRAWING: ms-zG-06-511 EL-01 I SCALE:3/8"=1'-O" DATE: 28.10.2025 DOC REF: AS-BUILT a A005 - - -- ELEVATION NOTES 1. ALL EXTERIOR ELEVATIONS SHALL REPRESENT TRUE AS-BUILT CONDITIONS, INCLUDING FINISHED GRADES,ROOF HEIGHTS,WINDOW AND DOOR LOCATIONS,AND STAMP MATERIAL TRANSITIONS. 2. EXTERIOR WALL CONSTRUCTION,CLADDING,AND WEATHER BARRIERS SHALL COMPLY WITH RCNYS SECTIONS R703 AND R704 FOR WEATHER RESISTANCE, WATER OF:HEWy MANAGEMENT,AND MATERIAL INSTALLATION. y�p�a+'H0 s°� 3. FINISHED GRADE ELEVATIONS SHALL BE SHOWN AND SHALL MATCH VERIFIED FIELD SURVEY DATA. ALL GRADES SHALL SLOPE AWAY FROM THE FOUNDATION AS REQUIRED BY RCNYS SECTION R401.3. ° 4. MAXIMUM BUILDING HEIGHT SHALL CONFORM TO THE TOWN OF SOUTHOLD ZONING CODE(§280),AND SHALL BE VERIFIED FROM AVERAGE GRADE TO THE HIGHEST POINT 102j0 OF THE ROOF. oFEssloN 5. ALL ROOF ASSEMBLIES SHALL COMPLY WITH RCNYS CHAPTER 9 FOR MATERIALS, 11/7/2025 INSTALLATION,AND DRAINAGE REQUIREMENTS.ROOF PITCH AND DRAINAGE SLOPES REVISION LOG SHALL BE CLEARLY INDICATED. TOP LEVEL____________________________ 6. EXTERIOR DOORS, WINDOWS, AND SKYLIGHTS SHALL BE NFRC-LABELED AND NO. REVISION INSTALLED WITH CODE-APPROVED FLASHING,SEALANTS,AND WEATHER-RESISTANT OPENING DETAILS PER RCNYS R609 AND R703. 7. EXTERIOR MATERIALS(SIDING,TRIM,MASONRY,STUCCO,OR PANEL SYSTEMS)SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER REQUIREMENTS AND RCNYS TABLE R703.4 FOR FASTENING AND SUPPORT. 8. ALL EAVES, SOFFITS, AND FASCIA SHALL BE CONSTRUCTED WITH APPROVED MATERIALS AND PROPER VENTILATION WHERE REQUIRED PER RCNYS SECTION R806. 9. ROOF AND WALL PENETRATIONS(VENTS,FLUES,EXHAUST TERMINALS,ELECTRICAL CEILING JOIST TOP______________________ MASTS)SHALL BE WEATHER-SEALED AND LOCATED AS SHOWN ON ELEVATIONS; CEILING JOIST SEPARATIONS FROM OPENINGS SHALL COMPLY WITH RCNYS MECHANICAL REQUIREMENTS. 10.GUTTERS, DOWNSPOUTS,AND ROOF DRAINAGE COMPONENTS SHALL DISCHARGE AWAY FROM THE FOUNDATION TO APPROVED DRAINAGE AREAS OR DRYWELLS AS SHOWN ON THE SITE PLAN. 11.ALL ELEVATION MATERIALS AND FINISHES SHALL MATCH FIELD-CONFIRMED CONDITIONS AND BE DOCUMENTED IN THE AS-BUILT DRAWINGS,INCLUDING COLOR, TEXTURE,AND MATERIAL TYPE. N CD r LPL J z FIRST FLOOR F.F.E 00° --------------- W +12'- CD Q c-� 0 Z J Y NJ M c� a � U � � c uj z � ~ Ld 0¢ JC'3z s CD m H ND FLOOR F.F.E C.;GROU y = Lo +02'-00° ---------- Q W N.G.L.-IqV+7067 00'__ ————- stiv Y v i X< I^ DRAWING TILTE l t I I' BASEMENT_F.F.E__________ O SIDE ELEVATION �07-00- <I �� �y�Rs y''�r'x�`,i�>x f��yr�a�? t 4 a r�<3�fi,F;s� fir'J� ✓:�?3(� F!5 w�' .'P'�"�,K'4:. I�R G CLIENT: HOME OWNER DRAFTSMAN: A.H REVIEWER: E.Z.H.B PROJECTID: 511 LEFT ELEVATION DRAWING: MS-ZG-06-511 EL-02 SCALE:3/8"=V-0" DATE: 28.10.2025 DOC REF: AS-BUILT a A006 ELEVATION NOTES 1. ALL EXTERIOR ELEVATIONS SHALL REPRESENT TRUE AS-BUILT CONDITIONS, INCLUDING FINISHED GRADES,ROOF HEIGHTS,WINDOW AND DOOR LOCATIONS,AND STAMP MATERIAL TRANSITIONS. 2. EXTERIOR WALL CONSTRUCTION,CLADDING,AND WEATHER BARRIERS SHALL COMPLY WITH RCNYS SECTIONS R703 AND R704 FOR WEATHER RESISTANCE, WATER SeoFNEWro MANAGEMENT,AND MATERIAL INSTALLATION. y�P P++HocyF RF 3. FINISHED GRADE ELEVATIONS SHALL BE SHOWN AND SHALL MATCH VERIFIED FIELD SURVEY DATA. ALL GRADES SHALL SLOPE AWAY FROM THE FOUNDATION AS s; REQUIRED BY RCNYS SECTION R401.3. 4. MAXIMUM BUILDING HEIGHT SHALL CONFORM TO THE TOWN OF SOUTHOLD ZONING a� CODE(§280),AND SHALL BE VERIFIED FROM AVERAGE GRADE TO THE HIGHEST POINT RoF... 01 OF THE ROOF. 5. ALL ROOF ASSEMBLIES SHALL COMPLY WITH RCNYS CHAPTER 9 FOR MATERIALS, ii/7/2025 INSTALLATION,AND DRAINAGE REQUIREMENTS.ROOF PITCH AND DRAINAGE SLOPES REVISION LOG TOP LEVEL________________ SHALL BE CLEARLY INDICATED. 6. EXTERIOR DOORS, WINDOWS, AND SKYLIGHTS SHALL BE NFRC-LABELED AND N0. REVISION INSTALLED WITH CODE-APPROVED FLASHING,SEALANTS,AND WEATHER-RESISTANT OPENING DETAILS PER RCNYS R609 AND R703. 7. EXTERIOR MATERIALS(SIDING,TRIM,MASONRY,STUCCO,OR PANEL SYSTEMS)SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER REQUIREMENTS AND RCNYS TABLE R703.4 FOR FASTENING AND SUPPORT. 8. ALL EAVES, SOFFITS, AND FASCIA SHALL BE CONSTRUCTED WITH APPROVED CEILING_JOIST TOP MATERIALS AND PROPER VENTILATION WHERE REQUIRED PER RCNYS SECTION R806. 9. ROOF AND WALL PENETRATIONS(VENTS,FLUES,EXHAUST TERMINALS,ELECTRICAL MASTS)SHALL BE WEATHER-SEALED AND LOCATED AS SHOWN ON ELEVATIONS; SEPARATIONS FROM OPENINGS SHALL COMPLY WITH RCNYS MECHANICAL REQUIREMENTS. I lei I I lei I I I I I I I I I I I I I I I I I I I I I I I I I I I I I L I I I I I I I I I I I I I I I I I I I 1 10.GUTTERS, DOWNSPOUTS,AND ROOF DRAINAGE COMPONENTS SHALL DISCHARGE AWAY FROM THE FOUNDATION TO APPROVED DRAINAGE AREAS OR DRYWELLS AS I[aH Mr i SHOWN ON THE SITE PLAN. 11.ALL ELEVATION MATERIALS AND FINISHES SHALL MATCH FIELD-CONFIRMED CONDITIONS AND BE DOCUMENTED IN THE AS-BUILT DRAWINGS,INCLUDING COLOR, TEXTURE,AND MATERIAL TYPE. cz rn I -�FIRST FLOOR F.F.E J z ----- O W o Z J0 u:) Y � a , C� �- O W � Off ¢ J ca z CDGROUND FLOORF.F.E m ~' -------------- Z ax = N.G.L._ W Lo ! >i i DRAWING TILTE r<i t j 13 K BASEMEN F- - ` F (E)REAR ELEVATION EL-03 CLIENT: HOME OWNER DRAFTSMAN: A.H REVIEWER: E.Z.H.B PROJECTID: 511 REAR ELEVATION DRAWING: MS-ZG-06-511 EL-03 SCALE:3/8"=1'-0" DATE: 28.10.2025 DOC REF: AS-BUILT A007 ELEVATION NOTES 1. ALL EXTERIOR ELEVATIONS SHALL REPRESENT TRUE AS-BUILT CONDITIONS, INCLUDING FINISHED GRADES,ROOF HEIGHTS,WINDOW AND DOOR LOCATIONS,AND STAMP MATERIAL TRANSITIONS. 2. EXTERIOR WALL CONSTRUCTION,CLADDING,AND WEATHER BARRIERS SHALL COMPLY WITH RCNYS SECTIONS R703 AND B704 FOR WEATHER RESISTANCE, WATER �EOf NElyy MANAGEMENT,AND MATERIAL INSTALLATION. ytP�a+'NOWT°qp 3. FINISHED GRADE ELEVATIONS SHALL BE SHOWN AND SHALL MATCH VERIFIED FIELD * ,t SURVEY DATA. ALL GRADES SHALL SLOPE AWAY FROM THE FOUNDATION AS e s REQUIRED BY RCNYS SECTION R401.3. 4. MAXIMUM BUILDING HEIGHT SHALL CONFORM TO THE TOWN OF SOUTHOLD ZONING CODE(§280),AND SHALL BE VERIFIED FROM AVERAGE GRADE TO THE HIGHEST POINT �ono3 l �FE OF THE ROOF. ssa/�/202s 5. ALL ROOF ASSEMBLIES SHALL COMPLY WITH RCNYS CHAPTER 9 FOR MATERIALS, INSTALLATION,AND DRAINAGE REQUIREMENTS.ROOF PITCH AND DRAINAGE SLOPES REVISION LOG SHALL BE CLEARLY INDICATED. ,t,TOP LEVEL----------------------------------------------------------_ 6. EXTERIOR DOORS, WINDOWS, AND SKYLIGHTS SHALL BE NFRC-LABELED AND NO. REVISION T+21'506j" INSTALLED WITH CODE-APPROVED FLASHING,SEALANTS,AND WEATHER-RESISTANT OPENING DETAILS PER RCNYS R609 AND R703. 7. EXTERIOR MATERIALS(SIDING,TRIM,MASONRY,STUCCO,OR PANEL SYSTEMS)SHALL ` BE INSTALLED IN ACCORDANCE WITH MANUFACTURER REQUIREMENTS AND RCNYS TABLE R703.4 FOR FASTENING AND SUPPORT. B. ALL EAVES, SOFFITS, AND FASCIA SHALL BE CONSTRUCTED WITH APPROVED MATERIALS AND PROPER VENTILATION WHERE REQUIRED PER RCNYS SECTION R806. CEILING JOIST TOP 9. ROOF AND WALL PENETRATIONS(VENTS,FLUES,EXHAUST TERMINALS,ELECTRICAL -------------------------------------------- MASTS)SHALL BE WEATHER-SEALED AND LOCATED AS SHOWN ON ELEVATIONS; Y+21'-06" SEPARATIONS FROM OPENINGS SHALL COMPLY WITH RCNYS MECHANICAL REQUIREMENTS. 10.GUTTERS, DOWNSPOUTS,AND ROOF DRAINAGE COMPONENTS SHALL DISCHARGE AWAY FROM THE FOUNDATION TO APPROVED DRAINAGE AREAS OR DRYWELLS AS SHOWN ON THE SITE PLAN. 11.ALL ELEVATION MATERIALS AND FINISHES SHALL MATCH FIELD-CONFIRMED f CONDITIONS AND BE DOCUMENTED IN THE AS-BUILT DRAWINGS,INCLUDING COLOR, TEXTURE,AND MATERIAL TYPE. N Lo O Z } U- Jz FIRST FLOOR F.F.E +12'-00"— ---------------------------------- Z W o CD3O ate = ZJcn W Y C U Q ZD O W L RH ❑ Z Ld CD Q J CD Z 5 F O HUMmI-- �GROUNDFLOORF.F.E (/� y Y_02'+ -00° —————_—____ a W v N G.L. i yK DRAWING TILTE BASEMENT F F.E 0T-00 S�n =------------------------------- (E) IDE ����� ���,,�n✓A,>, � .;i.,y._ p�r r?;��',v„±a�: ,.h„s;'1�x`�,5��� 4.�..�f°„x'4.1�i,' 3.�i`�,,,, � -:; S ELEVATION EL-04 CLIENT: HOME OWNER DRAFTSMAN: A.H REVIEWER: E.Z.H.B PROJECTID: 511 RIGHT ELEVATION DRAWING: MS-ZG-06-511 EL-04 SCALE:3/8°=1'-D° DATE: 28.10.2025 DOC REF: AS-BUILT A008 'Road COMPLY WITH ALL CODES OF APPROVED AS NOTED NEW YORK STATE&TOWN CODES AS REQUIRED AND CONDITIONS OF M MO1D MM ZBA FEE W, 01) BY SOIJElD tOWN PUWMNG Bp0 SOUiNOLD TOWNTRUSTEES NOTIFY BUILDING DEPARTMENT AT 631-765-1802 8AM TO 4PM FOR THE N.U.DEC FOLLOWING INSPECTIONS: Oman FOUNDATION-TWO REQUIRED SCHD FOR POURED CONCRETE ROUGH-FRAMING&PLUMBING INSULATION FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ELECTRICAL ALL CONSTRUCTION SHALL MEET THE INSPECTION REQUIRED REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS Additional Provide windborne debris Certification protection for new exterior May Be Required. glazing on buildings as per NYS Code. GENERAL NOTES RESIDENTIAL CODE OF NY STATE(RCNYS 2020) BUILDING ENVELOPE NOTES AS-BUILT DOCUMENTATION FOR EXISTING ONE-FAMILY DWELLING: 1. THESE PLANS ARE PREPARED FOR BUILDING PERMIT PURPOSES FOR AN EXISTING SINGLE- 1. ALL AS-BUILT WORK SHALL COMPLY WITH THE RESIDENTIAL CODE OF NEW YORK STATE 1. THE BUILDING ENVELOPE SHALL COMPLY WITH THE RESIDENTIAL CODE OF NEW YORK 645HAMILTON AVE,MATTITUCX,SOUTHOLD,NY11952 "•' !$ "'• 1 FAMILY RESIDENCE.A LICENSED PROFESSIONAL ENGINEER OR ARCHITECT WILL REVIEW AND (RCNYS 2020),BUILDING CODE OF NEW YORK STATE(BCNYS 2020),ENERGY STATE(RCNYS 2020),BUILDING CODE OF NEW YORK STATE(BCNYS 2020).AND ENERGY I 's CERTIFY COMPLIANCE WITH APPLICABLE CODES AND STANDARDS CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE(ECCCNYS 21D20).NATIONAL CONSERVATION CONSTRUCTION CODE OF NEYV YORK STATE(NYSECCC/ECCCNYS 2D20) f 2. THE DESIGN PROFESSIONAL IS NOT RESPONSIBLE FOR CONSTRUCTION ADMINISTRATION; ELECTRICAL CODE(NEC 2020-NFPA 70),AND APPLICABLE SUFFOLK COUNTY AND FOR ALL THERMAL.MOISTURE,AND STRUCTURAL PERFORMANCE REQUIREMENTS. !J, ��. 6TAMP ALL DUTIES,INCLUDING SITE SAFETY,SECURITY.AND ANY PROPERTY,VEHICLE,OR TOWN OF SOUTHOLD REGULATIONS 2.ALL EXTERIOR WALLS.ROOFS FLOORS,WIN OOWS,AND DOORS SHALL MEET OR EXCEED THE EQUIPMENT DAMAGE,ARE SOLELY THE RESPONSIBILITY OF THE HOMEOWNER OR 2. EXISTING CONDITIONS SHALL BE FIELD-VERIFIED AND DOCUMENTED ACCURATELY IN MINIMUM R-VALUFS,U-FACTORS,AND SHGC LIMITS FOR CLIMATE ZONE 4 AS LISTED IN APR /-. °`NEwrP F GENERAL CONTRACTOR AS-BUILT DRAWINGS,INCLUDING DIMENSIONS,STRUCTURAL ELEMENTS,MECHANICAL, ECCCNYS TABLE F402-U. ' Q 207{� 3. GENERAL CONTRACTOR SHALL STUDY DRAWINGS,SPECIFICATIONS AND FIELD VERIFY ELECTRICAL,AND PLUMBING COMPONENTS. 3.A CONTINUOUS AIR BARRIER AND VAPOR RETARDER WHERE REQUIRED,SHALL BE L1/ GRADE EXTENT AND COMPATIBILITY WITH THE EXISTING SITE CONDITIONS BEFORE 3. STRUCTURAL ELEMENTS SHALL CONFORM TO RCNYS CHAPTERS 3-5 AND BCNYS INSTALLED IN ACCORDANCE WITH RCNYS SECTION RI AND ECCCNYS R402.4,WITH ALL - COMMENCING THE WORK ANY DISCREPANCIES FOUND SHALL BE REPORTED INIYRITING REQUIREMENTS FOR FOUNDATIONS,FRAMING,LOAD PATHS,AND WIND RESISTANCE FOR JOINTS.SEAMS.AND PENETRATIONS SEALED TO MINIMIZE AIR LEAKAGE F PRIOR TO CONSTRUCTION. WALL AND CLIMATE ZONE 4(SUFFOLK COUNTY). 4.WALL AND ROOF ASSEMBLIES SHALL INCLUDE APPROVED FLASHING,WEATHER-RESISTANT 4.GENERAL CONTRACT0 1 d SUB-CONTRACTOR SHALL STRICTLY FOLLOW THE DRAWINGS BARRIERS,AND DRAINAGE PLANES PER RCNYS SECTIONS R703 AND R903 TO PREVENT d NOTES AND ENSURE ALL WORK COMPLIES WITH THE APPLICABLE STATE BUILDING 4.ANY MODIFICATION OR REPAIR TO LOAD BEARING WALLS,BEAMS,OR FOUNDATIONS MOISTURE INTRUSION AND ENSURE LONG-TERM DURABILITY. ' 4/7/202b CODESANDLOCALAMENDMENTS. SHALL BE DOCUMENTED AND CERTIFIED AS EQUAL OR GREATER IN STRENGTH TO 5. ALL FENESTRATION SHALL BE NFRC-LABELED AND DEMONSTRATE COMPLIANCE WITH ' THE ORIGINAL DESIGN. MAXIMUM U-FACTOR AND SHOO LIMITS,WITH INSTALLATION IN ACCORDANCE WITH 5. GENERAL CONTRACTOR SHALL FOLLOW THE MORE STRINGENT PROVISION OF THE aS - 5. THE BUILDING ENVELOPE SHALL COMPLY WITH ECCCNYS 2D20 MINIMUM INSULATION MANUFACTURER SPECIFICATIONS AND CODE-APPROVED FLASHING DETAILS. REVISION LOG APPLICABLE BUILDING CODE IN CASE OF CONFLICTING CODE PROVISIONS. (R-VALUE)AND MAXIMUM U-FACTOR REQUIREMENTS FOR CLIMATE ZONE 4,WITH 6. BUILDING ENVELOPE ASSEMBLIES SHALL COORDINATE PITH STRUCTURAL SYSTEMS IN ,f N0. REVISION 6. GENERAL CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UNDERGROUND OR OVER VERIFIED LOCATIONS OF INSULATION AND AIR/VAPOR BARRIERS. ACCORDANCE WITH RCNYS CHAPTERS 3-5 AND BCNYS STRUCTURAL PROVISIONS, HEAD UTILITIES,INCLUDING SANITARY SEWER WATER,GAS,AND ELECTRICITY BEFORE 6. WINDO'N5,DOORS.AND SKYLIGMS SHALL BE NFRC-LABELED AND MEET ECCCNYS AODRESSINGWIND,SNOW,AND UPLIFT LOADS APPLICABLE TO SUFFOLK COUNTY. N b EXCAVATION OR CONSTRUCTION WORK R402.11 TABLE VALUES.SHALL PERFORMANCE INSTALLATION FOLLOY/MANUFACTURER'S 7.MECHANICAL AND ELECTRICAL PENETRATIONS THROUGH THE BUILDING ENVELOPE 7. GENERAL CONTRACTOR SHALL ENSURE MINIMUM COVER FOR WATER LINES IS 4 FEET, INSTRUCTIONS AND CODE-APPROVED FLASHING DETAILS. SHALL MAINTAIN THE CONTINUITY OF INSULATION AND AIR BARRIERS.AND ALL LIGHTING OR FOR DRY UTILITIES IS 3 FEET,AND FOR PVC SEWER LINES IS 2 FEET. EXTERIOR ELECTRICAL COMPONENTS SHALL COMPLY WITH NEC 2D20 AND NYSECCC 7. MECHANICAL SYSTEMS SHALL BE VERIFIED FOR COMPLIANCE WITH RCNYS CHAPTER 15 AND EFFICIENCY REQUIREMENTS. & GENERAL CONTRACTOR SHALL ENSURE ALL PAVED SURFACES SHALL BE AT A 05%MIN. NYSECCC HVAC EFFICIENCY REQUIREMENTS.ALL COMBUSTION APPLIANCES SHALL HAVE 8. SITE AND BUILDING ENVELOPE DOCUMENTATION SHALL INDICATE BUILDING LOCATION, SLOPE ALL GRASSED AND LANDSCAPED AREAS SHALL BE AT A I%MINIMUM SLOPE ADEQUATE COMBUSTION AIR AND VENTING. SETBACKS,GRADING,AND DRAINAGE IN COMPLIANCE WITH THE TOWN OF SOUTHOLD 9. GENERAL CONTRACTOR SHALL VERIFY REQUIRED PROPERTY SETBACKS,LOT COVERAGE A ELECTRICAL SYSTEMS SHALL COMPLY WITH NEC 2023 AND BE VERIFIED FOR CIRCUIT ZONING CODE(4280)AND SUFFOLK COUNTY AMENDMENTS ADDRESSING STORMWATER AND BUILDING HEIGHT LIMIT AS PER LOCAL ZONING ORDINANCE CAPACITY.GROUNDING,AFG/GFG PROTECTION.AND PANEL LABELING.ALL EXISTING MANAGEMENT,FLOOD ZONES,AND COASTAL RESILIENCE 10.GENERAL CONTRACTOR SHALL ENSURE THE PROVISION OF CONTROL AND EXPANSION CIRCUITS SHALL BE DOCUMENTED AND UPDATED WHERE NECESSARY. JOINTS ON THE CONCRETE DRIVES,WALKS,AND PATIOS AS MENTIONED IN THE 9. PLUMBING SYSTEMS SHALL COMPLY WITH THE NEW YORK STATE PLUMBING CODE DRAWINGS (NYSPC).WITH VERIFIED PIPE SIZES,MATERIALS,FIXTURE LOCATIONS,AND PROPER FIRE SAFETY NOTES LOCATION PLAN 11.GENERAL CONTRACTOR SHALL COORDINATE ARCHITECTURAL,STRUCTURAL VENTING AND TRAP INSTALLATIONS. MECHANICAL ELECTRICAL,PLUMBING&MILLWORK TRADES PROPERLY WITH 10.FIRE SAFETY SHALL BE VERIFIED PER RCNYS SECTIONS R302-R315,INCLUDING L 1. ALL FIRE SAFETY PROVISIONS SHALL COMPLY WITH THE RESIDENTIAL CODE OF NEW YORK _ RESPECTIVE SUB-CONTRACTORS TO ENSURE EFFICIENT SITE EXECUTION d ACTIVITY FIRE-RESISTIVE CONSTRUCTION.PROTECTED PENETRATIONS,AND THE INSTALLATION OF $TATE(RCNYS 2020).FIRE CODE OF NEWYORK STATE(FCNYS 2020).AND ANY APPLICABLE SEQUENCING. SMOKE AND CARBON MONOXIDE DETECTORS AS REQUIRED.2. SUFFOLK COUNTY AND TOWN OF SOUTHOLD AMENDMENTS. 12.GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING SHOP DRAWINGS OF 11.ALL EGRESS DOORS,STAIRS,GUARDS,AND HANDRAILS SHALL COMPLY WITH RCNYS 2.ALL SMOKE ALARMS SHALL BE INSTALLED IN ACCORDANCE WITH RCNYS SECTION R314, L MILLWORK STONEWORK OUTDOOR STRUCTURES AS REQUIRED BY THE COUNTY OR CHAPTER 3 REQUIREMENTS FOR WIDTH,HEIGHT,RISE RUN,AND SAFETY. PROVIDED IN EACH SLEEPING ROOM,OUTSIDE EACH SLEEPING AREA,AND ON EVERY STORY PERMITTING AUTHORITY. OF THE DWELLING,INCLUDING BASEMENTS.SMOKEALARMS SHALL BE HARD-WIRED WITH 12.SITE PLANS SHALL SHOW EXISTING STRUCTURE LOCATIONS.PROPERTY LINES,AND BATTERY BACKUPAND INTERCONNECTED WHERE REQUIRED. ]3.GENERAL CONTRACTOR SHALL CONTACT BII AND OBTAIN UTILITY-LOCATE CLEARANCE SETBACKS PER TOWN OF SOUTHOLD ZONING CODE 4280 AND ANY LOCAL AMENDMENTS 3. r s• WELLINAOVANCE OF ANY EXCAVATION,FOLLOWING THE REQUIRED NOTICE PERIOD AND FOR LOT COVERAGE AND BUILDING HEIGHT. 3.CARBON MONOXIDEALARMSSHALL BE INBTALLED PER RCNYS SECTION R3150UTSIOEOF _ 0 SCHEDULING GUIDELINES AND WITHIN PROXIMITY TO ALL SLEEPING AREAS AND IN ANY DWELLING UNIT THAT _ Z> 13.GRADING,DRAINAGE,AND STORMWATER MANAGEMENT SHALL CONFORM TO TOWN OF CONTAINS FUEL-FIRED APPLIANCES OR HAS AN ATTACHED GARAGE -T` A.� - '.� LL JZ 1/ CONTINUOUS THE CAIR-TIGH TOR NESSENSUAND ADEQUATE INSULATION.RE A PROPERLY DEMON BU STRATING NG PE WITH SOUTHOLO AND SUFFOLK COUNTY REGULATIONS,INCLUDING REQUIREMENTS FOR 4. 4. ALL FIRE-RESISTANCE-RATED CONSTRUCTION,INCLUDING WALLS,FLOORS,CEILINGS,AND _ �J HIGH-QUALITY A] THROUGHOUT COASTAL FLOOD.AND STORM RESILIENCE AREAS. STRUCTURAL MEMBERS SHALL COMPLY WITH RCNYS SECTION R301.ASSEMBLIES BETWEEN 'r O WO 14.AS-BUILT DOCUMENTATION SHALL INCLUDE UPDATED FLOOR PLANS,ELEVATIONS, DWELLING UNITS,GARAGES,AND HABITABLE SPACES SHALL MAINTAIN THE REQUIRED FIRE l �' �_ 15.GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING THE BUILDING PERMIT SEPARATION AND RATING. a O STRUCTURAL DETAILS,MECHANICAL AND ELECTRICAL LAYOUTS,AND SITE INFORMATION 5. I APPLICATION TO THE RELEVANT COUNTYXITY AND PROVIDING REQUIRED SUPPORTING ASVERIFlEDON SITE S PENETRATIONS OF RRE-RESISTANCE-RATED ASSEMBLIES BY PIPES,DUCTS,CABLES,OR DOCUMENTS,ENSURING COMPLIANCE WITH LOCAL PERMITTING REQUIREMENTS. CONDUITS SHALL BE PROTECTED WITH APPROVED FIRESTOPPING MATERIALS IN 15.ALL WORK SHALL BE SUBJECT TO REVIEW AND APPROVAL BY THE TOWN OF SOUTHOLD ACCORDANCE RCNYS SECTION R302.11 TO MAINTAIN THE INTEGRITY FIRE �j 16.GENERAL CONTRACTOR SHALL COORDINATE NS,AND WITH THE LOCAL BUILDING l _ LLJ BUILDING DEPARTMENT.ANY FIELD CHANGES SHALL BE DOCUMENTED IN THE FINAL BARRIER. DEPARTMENT FORSCHEDULING,RE-INSPECTIONS,AND DOCUMENTATION. AS-BUILT PACKAGE PRIOR TO PERMIT CLOSE-OUT.6. QI- 17.GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING AND QUALIFYING 6. EXTERIOR WALL OPENINGS AND PROJECTIONS SHALL COMPLY WITH THE FIRE SEPARATION I6.ACCESSIBILITY FEATURES,WHEREAPPLILABIE,SHALL FOLLOW BUILDING CODEOFNEV! DISTANCE REQUIREMENTS OF RCNYS TABLE R302.1(1)BASED ON DISTANCE TO PROPERTY I O W� BUILDING INSPECTIONS,INCLUDING FOUNDATION,FRAMING,ROUGH-IN TRADES,AND YORK STATE(BCNYS 2020)FOR UNIVERSAL DESIGN AND REASONABLE LINES AND ADJACENT STRUCTURES AS REQUIRED BY THE TOWN OF SOUTHOLD ZONING CODE GETTING OCCUPANCY CERTIFICATE ACCOMMODATION,EVEN THOUGH SINGLE-FAMILY DWELLINGS ARE GENERALLY EXEMPT 7. HEATING EQUIPMENT.FIREPLACES.AND CHIMNEYS SHALL BE INSTALLED IN ACCORDANCE y= G z 18,GENERAL CONTRACTOR SHALL MAINTAIN ALL INSPECTION APPROVALS AND CORRECTION FROM ADA REQUIREMENTS,7, WITH RCNYS CHAPTERS IO AND II,ENSURING PROPER CLEARANCES FROM COMBUSTIBLES, NOTICES ON SITE AND PROVIDE COPIES TO THE HOMEOWNER d ENSURE ALL TRADES 17.ALL UTILITY CONNECTIONS.INCLUDING WATER.SEWER,GAS AND ELECTRIC SERVICE REQUIRED HEARTH EXTENSIONS,AND USE OF LSTEDAND LABELED COMPONENTS PROJECT INFORMATION CODE COMPLIANCE J ARE PREPARED AND PRESENT FOR THDA RESPECTIVE INSPECTIONS Z Z SHALL BE VERIFIED AS EXISTING AND FUNCTIONAL ANY UPGRADES OR CHANGES SHALL 8.EGRESS WIN DONS.DOORS,AND PATHWAYS SHALL MEET THE REQUIREMENTS Of RCNYS ��O 19.ALL DIMENSIONS ARE TO THE FACE OF THE STUD UN0:4'WALLS REPRESENT ZX4 COMPLY WITH SUFFOLK COUNTY HEALTH DEPARTMENT AND LOCAL UTILITY AUTHORITY SECTION R310,PROVIDING SAFE AND UNOBSTRUCTED MEANS OF ESCAPE IN ALL SLEEPING SCOPEOFWORK: AS-BUILT DOCUMENTATION FOR EXISTING ONE-FAMILY RCNYS 2020;RESIDENTIAL CODE OF NEW YORK STATE m~� FRAMING AND 6'WALLS REPRESENT 2X6 FRAMING. STANDARDS 8. ROOMS AND HABITABLE SPACES BELOW THE FOURTH STORY. N- NOS 9.FIRE EXTINGUISHERS SHALL BE INSTALLED NI ACCESSIBLE LOCATIONS IN ACCORDANCE WITH DWELLING BCNYS 2020:BUILDING MECHANICAL COD NEW YORK NEW YORK TE STATE 20.DON FACTOSCALE N.TS DRAWINGS;WRITTEN DIMENSIONS TAKE PRECEDENCE OVER ANY 1S MODIFIED ORAIWITIONS SINGCLEARLY STANDARD RAPHICBETWEENCONVENTIONS. TIONS.ALL DIMENSION NFPA IO RECOMMENDATIONS,TYPICALLY NEAR KITCHENS,MECHANICAL ROOMS,AND ADDRESS: ADDRES645 S ONE-FAMILYTON AVE, RTITUENCEED TOR NY IIS52 MCNY5202. PLUMBING CODE OF NEW YORK STATE Q W= SCALE FACTOR MODIFIED CONDITIONS USING STANDARD GRAPHIC CONVENTIONS.ALL DIMENSIONS,9. PROPERTY TYPE: ADDRESS ONE-FAMILY RESIDENCE(25TOREY) PCNY5202P.PLUMBING CODE OF NEWYORK STATE 21,IN CASE OF CONFLICTING INFORMATION,TECHNICAL NOTES SHALL TAKE PRECEDENCE OVER MATERIALS.AND CODE REFERENCES SHALL BE ACCURATE AND FIELD-CONFIRMED. GARAGES. OCCUPANCY GROUP. RA NEC 2020:NATIONAL ELECTRICAL CODE(NFPA 70) THE DRAWINGS. 19.FINAL INSPECTIONS AND APPROVALS SHALL BE COORDINATED WITH THE TOWN OF 10.ALL FIRE SAFETY DEVICES AND MATERIALS SHALL BE VERIFIED ON SITE FOR PROPER CONSTRUCTION TYPE: TYPE-VB FCNYS 2020:FIRE CODE OF NEW YORK STATE SOUTHOLD BUILDING DEPARTMENT,INCLUDING STRUCTURAL ELECTRICAL,PLUMBING, INSTALLATION,OPERATION,AND LABELING PRIOR TO FINAL INSPECTION AND APPROVAL BY (APN) 10DO1400002DDOOICOO ECNYS 2020;EXISTING BUILDING CODE OF NEW YORK STATE 10.MECHANICAL,AND FINAL CERTIFICATE OF OCCUPANCY INSPECTIONS. THE TOWN OF SOUTHOLD BUILDING DEPARTMENT. COUNTY: SUFFOLK COUNTY TOWN OF SOUTHOLD ZONING REGULATIONS:LOCALZONING AND LAND USE ZONING: N/A REQUIREMENTS CLIMATEZONE 4A(MIXED-HUMID) ARCHITECTURAL ABBREVIATIONS ARCHITECTURAL SYMBOLS STANDARD HATCHES SHEET INDEX DRAWING TILTE PAVERS SHEET DRAWINGTITLE REVISION AF.F ABOVE FINISHED FLOOR DI AG. DIAGONAL MFR MANUFACTURER )0004%X GODO ARCHITECTURE COVER SHEET 00 AS.0 ABOVE SUSPEND CEILING D.B.L DOUBLE MAT. MATERIAL SQD''OO ASPHALT PAVJSAND CIVIL AP ACOUSTICAL PLASTER MAX MAXIMUM ACT ACOUSTICAL TILE EA EACH MIN. MINIMUM BLDG.LEVEL MARKER COOL (ESITEPLAN EF EACH FACE MISL. MISCELLANEOUS BLDGSEGMARKER ^ ROOFING ARCHITECTURE B/S BOTH SIDES ELEV. ELEVATION MA MANHOLE `) LAN B/V/ BOTH WAYS EQ. EQUAL MS MUD SILL �4 i A002 (EIBASEMENFOORPL FLOOR N B.W BETWEEN EQUPT. EQUIPMENT O__I _ 0 WOOD/LUMBER AA0033 (EGROUNDBOOR PLAN B.T.P BOTTOM PLATE EXP. EXPOSED (N) NEW (E)FIRST FLOOR PLAN BLDG. BUILDING EXT. EXTERIOR N.T.S NOT TO SCALE FTC,SECTION MARKER I CONCRETE A034 (E)ROOF LAYOUT PLAN B.L BOUNDARYLINE GRIDLINESMARKER A005 (E)FRONT ELEVATION EL-01 F.X FIXED LANDSCAPE CLG. CEILING F.I.B FIBER GLASS INSULATION 0/C ON CENTER F---I A006'���'�'�'��' (ESIDE ELEVATION EL-02 CLG.HT CEILING HEIGHT FIN. FINISH PR./(P) PROPOSED II A007 (E)SIDE ELEVATION EL-03 CLR. CLEAR FA FIREALARM PR, PLYWOOD BLDG ELEV.MARKER -J ® EK{PR.BUILDING. A008 (E)SIDE ELEVATION EL-04 CLIENT: HOMEOWNER CSMNT. CASEMENT F.E FIRE EXTINGUISHER P,L PROPERTY LINE DRAFTSMAN: RIFHAN CAB. CABINET FLO FIRE EXTINGUISHER CABINET PAN. PANTRY DETAILCALLOUT STONE PAV. CT CERAMICTILE F.T FLOOR TRAP REVIEWER: HE CL CLOSET FS.B.L FRONT SETBACK LINE REF. REFRIGERATOR ® SIDING RS.B.L REAR SETBACK LINE BLDG.ELEV.MARKER PROJECT ID: 511 0 OET. DETAIL GYP. BID GYPSUM BOARD FIND. RANGE EAST H DRAWING: MS-ZG-06-511 DIA DIAMETER GC GENERAL CONTRACTOR ON DOUBLEHUNG SM SINGLE HUNG .m TAGS DATE: 07.04.2026 EX.ITO EXISTING TINT. INTERIOR SLOG. SLIDING , ® CMU BLOCKS D/W DISHWASHER SPECS. SPECIFICATIONS D/R DRYER LV.P LUXURY VINYL PLANK STRD. STANDARDS IRA.ELEV.MARKERS ® BRICK DOC REF: AS-BUILT DEMO. DEMOLISH LAV. LAVATORY SUSP. SUSPENDED DIET. DETAIL LAB. LABORATORY S.0 SHOWERCABIN s r INSULATION /'G 000 O O STAIR DIRECTION ARROW NORTH DIRECTION ARROW 1/`,/,-I Ix CIVIL NOTES 1. 1963 SURVEY REMAINS THE OFFICIAL RECORD ON FILE WITH THE TOWN OF SOUTHOLD. L ALL CMLAND SITE WORK SHALL COMPLY WITH THE RESIDENTIAL CODE OF NEW YORK STATE(RCNYS 2020),BUILDING CODE OF NEW YORK STATE(BCNYS 202D),AND THE TOWN OF SOUTHOLD ZONING CODE (02B0), INCLUDING SUFFOLK COUNTY STAMP STORMWATERAND GRADING REGULATIONS. 3. THE AS-BUILT SITE PUN SHALL SHOW PROPERTY LINES,STRUCTURE FOOTPRINT, tEOF xewy° SETBACKS.EASEMENTS.DRIVEWAY,WALKWAYS,DRAINAGE,AND ALL EXISTING a`yUA- Q UTILITIES AS VERIFIED BY FIELD MEASUREMENT. 0 4.FINAL GRADING AROUND THE BUILDING SHALL SLOPE A MINIMUM OF 5%AWAY FROM o THE FOUNDATION FOR THE FIRST 10 FEET IN COMPLIANCE WITH RCNYS SECTION �,F o i R4013.TO PREVENT WATER ACCUMULATION AT THE FOUNDATION. 9jOyAssw°"'` 5. STORMWATER MANAGEMENT SYSTEMS.INCLUDING DRYWELLS.CATCH BASINS, AND SWALFS,SHALL BE INSTALLED AND MAINTAINED PER SUFFOLK COUNTY AND 4/Z/2026 TOWN OF SOUTHOLD REQUIREMENTS.WITH LOCATIONS VERIFIED IN THE FIELD. 6. WATER SUPPLY AND SANITARY SYSTEMS SHALL CONFORM TO THE NEW YORK STATE REVISION LOG PLUMBING CODE(NYSPC)AND SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES (SCDHS)REGULATIONS.INCLUDING VERIFIED TANK AND LEACH FIELD LOCATIONS. NO. REVISION I 7. ALL UNDERGROUND ELECTRICAL AND COMMUNICATION CONDUITS SHALL BE ` INSTALLED PER NEC 2020 MINIMUM BURIAL DEPTHS AND IDENTIFIED ON THE ° AS-BUILT DRAWINGS. B. RETAINING WALLS STEPS,OR GRADE CHANGES OVER 4 FEET IN HEIGHT SHALL O BE VERIFIED FOR STRUCTURAL STABILITY AND BUILT IN ACCORDANCE WITH BCNYS SECTION 1807.INCLUDING PROPER DRAINAGE BEHINDWALLS. R35'4z 9.ALL SITE ELEVATIONS SHALL BE BASED ON APPROVED SURVEY BENCHMMKS AND flEPORTED IN NORTH AMERIGN VERTICAL DATUM(NAVD 88).THE LICENSED �r . SURVEYOR SHALL CERTIFY FINAL ELEVATIONS AND LOT DRAINAGE R81'-9" �+ 10.ANY WORK LOCATED IN FLOOD HAZARD OR COASTAL ZONES SHALL COMPLY WITH THE �, TOWN OF SOUTHOLD FLOOD DAMAGE PREVENTION ORDINANCE(4275)AND FEMA 9� BASE FLOOD ELEVATION REQUIREMENTS. ` 11.ALL SITE IMPROVEMENTS,INCLUDING GRADING,DRAINAGE,AND LANDSCAPING, 'P� SHALL BE COMPLETED AND VERIFIED PRIOR TO FINAL INSPECTION AND CERTIFICATE OF OCCUPANCY APPROVAL BY THE TOWN OF SOUTHOLD BUILDING 9O DEPARTMENT. LEGAL INFORMATION EN ADDRESS: 645 HAMILTON AVE.MATTITUCK.SOUTHOLD.NY 0 Z} LOT NO.: 2 Z J LOTAREA: 0.38 ACR W p ASSESSORS PARCEL NUMBER 10OD140DO0200001000 ZONING DESIGNATION: N/A a Q CS,AREA STATEMENT z J x W c2 LOT AREA -_-------. jj� ._-.___038 ACRE ^2 a r PRINCIPLE BUILDING BUILT UP AREA ------11335Q.FT OLLK ACCESSORY STRUCTURES BUILT UP AREA ---.... —..................... 1573 67 SQPT U W o .s 4 \ •,.,-.......I,: a r %IMPERVIOUS AREA --.___.---------------------------'---18.2 O¢ ` a% PARKING AREA 30485Q.Ff O %PERVIOUS AREA 7i1 0 SITE PLAN LEGEND z o PROPERTY LANE Q W= O.E— OVERHEAD ELECTRICAL LINES UNDERGROUND ELECTRICAL LANES G.L GAS LINE ,\.:.'; :..Y`: . I.�Oti W.L WATERLINE •,' " ` ` ` -" W G.L SEWER LINE f�\. ,>'�,.-', •-,.' y` ` `W` `4/ —COMNE.— TELECOMMUNICATION LANE ` —X—X—X— WOODENFENCE �\"'•.-`} �,` �, �,` - IRON FENCE ----- T240- corvroufls DRAWING TILTE WATER DRAINAGE FLOW DIRECTION \ti;•`. ..;'C .. .. OO MANHOLE ® BOLLARD ♦ +`` WATERMETER UGHTPOLE /:•,j/ 0 ENERGY METER UTIUTYPOLE (E)SITEPLAN ✓� GM GAS METER N FIRE HYDRANT LOT 6520 W.Y WATERVALVE Q TREE : QGv GAS VALVE °OS DOWNSPOUT �OC1 3 T,:"v,',`3C:-. CONCRETE ® PAVERS CLIENT: HOMEOWNER A0 LANDSCAPE ASPHALTPAV. DRAFTSMAN: RIFHAN REVIEWE �Q ® DUPR BUILDING ROOFING PROJECT R ID: 11 0 STONEPAV. ® BRICK DRAWING: MS-ZG-06-511 DATE: 07.04.2026 DOC REF: AS-BUILT cool ARCHITECTURAL NOTES U 1. ALL ARCHITECTURAL WORK SHALL COMPLY WITH THE RESIDENTIAL CODE OF NEW YORK STATE(RCNYS 2020).BUILDING CODE OF NE3V YORK STATE(BCNYS2020), ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE(ECCCNYS 2020, STAMP AND THE TOWN OF SOUTHOLD ZONING CODE(5290). 2. ALL EXISTING CONDITIONS,DIMENSIONS,AND MATERIALS SHALL BE FIELD-VERIFIED PRIOR TO PREPARATION OF FINAL AS-BUILT DRAWINGS.ANY VARIATION FROM "�d!,"a"•. 3 APPROVED PUNS SHALL BE DOCUMENTED AND SUBMITTED TO THE BUILDING EL- c DEPARTMENT. A00T 3. ALL FLOOR PLANS,ELEVATIONS,SECTIONS,AND DETAILS SHALL REPRESENT TRUE `L AS-BUILT CONDITIONS,INCLUDING STRUCTURAL MEMBERS,PARTITIONS,OPENINGS. �gaEes CEILING HEIGHTS.AND FINISHES. 4. ALL MATERIALS AND CONSTRUCTION DETAILS SHALL CONFORM TO RCNYS CHAPTER 3 4/7/2D26 26' FOR BUILDING PLANNING AND CHAPTER 7 FOR WALL COVERINGS AND INTERIOR FINISHES. REVISION LOG 5. ALL INTERIOR FINISH MATERIALS SHALL COMPLY WITH FLAME-SPREAD AND NO. REVISION SMOKE-DEVELOPED INDEX REQUIREMENTS OF RCNYS TABLE R3029. --k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c BACKUP AND INTERCONNECTION WHERE REQUIRED. Q ® ® 11. THERMAL ENVELOPE ELEMENTS(INSULATION.MR BARRIER AND VAPOR RETARDER) Z. SHALL BE DOCUMENTED AND VERIFIED TO MEET ECCCNYS R402 MINIMUM BASEMENT HALL PERFORMANCE VALUES FOR CLIMATE ZONE/. HOTWATFR 25'-0PX20'41' 12. ALL ATTIC AND CRAWL SPACE VENTILATION SHALL COMPLY WITH RCNYS R806 HEATER CLG.OF-W AND R408 TO ENSURE ADEQUATE MR CIRCULATION AND MOISTURE CONTROL w rn EL-2 EL-1 13. ALL ARCHITECTURAL OPENINGS FOR ELECTRICAL, PLUMBING, AND HVAC PENETRATIONS SHALL BE SEALED TO MAINTAIN THE CONTINUITY OF FIRE AIR O Z} A006 A008 AND MOISTURE BARRIERS. ILL.,J ci FURNACE 14. ACCESSIBILITY FEATURES,WHERE APPLICABLE,SHALL CONFORM TO BCNYS 202D Z J- SECTION 1107 FOR RESIDENTIAL USE AND UNIVERSAL DESIGN ELEMENTS, 0 W Z. RECOGNIZING THAT SINGLE-FAMILY HOMES ARE GE14ERALLY EXEMPT FROM ADA ccQ o REQUIREMENTS. 15. ALL EXTERIOR ELEVATIONS SHALL SHOW FINISHED GRADE LINES,ROOF HEIGHTS.AND y' MATERIAL TRANSITIONS IN COMPLIANCE WITH TOWN OF SOUTHOLD HEIGHT AND SETBACK REGULATIONS LLA u ¢ 16. MECHANICAL, ELECTRICAL, AND PLUMBING FLKTURE LOCATIONS SHALL BE =-cc F COORDINATED WITH ARCHITECTURAL DRAWINGS AND FIELD-VERIFIED F03AS-BUILT F- ACCURACY. O W cl 17. ENERGY EFFICIENT LIGHTING AND APPLIANCES SHALL COMPLY WITH NEC 2020 Q Z ANDECCCNYSELECTRICALEFFICIENCYREQUIREMENTS F,�¢ 18. ATTIC ACCESS AND CRAWL SPACE ACCESS OPENINGS SHALL BE PROVIDED IN J CRAWL SPACE CRAWLSPACE ACCORDANCE WITH RCNYS R807 AND R408 AND SHALL RE CLEARLY DOCUMENTED ON z O 17-06'X03'-0P LF-04'X03'-03' - AS-BUILT DRAWINGS. m H CLG.OR-W Q' CLG. 19. ALL ARCHITECTURAL WORK AND FIELD MODIFICATIONS SHALL BE SUBJECT TO FINAL X INSPECTION AND APPROVAL BY THE TOWN OF SOUTHOLD BUILDING DEPARTMENT W PRIOR TO ISSUANCE OF CERTIFICATE OF OCCUPANCY. IX 13'-2" 12'-10" A 26' DRAWING TILTE EL-1 AOOi (E)BASEMENT FLOOR PLAN CLIENT: HOMEOWNER DRAFTSMAN: RIFHAN REVIEWER: KE PROJECT ID: 511 DRAWING: MS-ZG-06-511 DATE: 07.04.2026 BASEMENT PLAN DOC REF: AS-BUILT FP-01 I SCALE:3/8"=1'-O" A001 ARCHITECTURAL NOTES EL-3 U 1. ALL ARCHITECTURAL WORK SHALL COMPLY WITH THE RESIDENTIAL CODE OF NEW AOO7 YORK STATE(RCNYS 2020).BUILDING CODE OF NEW YORK STATE(BCNYS 2020). STAMP ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE(ECCCNYS 2020), 35' AND THE TOWN OF SOUTHOLD ZONING CODE(5280). Y wA II, 2. ALL EXISTING CONDITIONS,DIMENSIONS,AND MATERIALS SHALL BE FIELD-VERIFIED 8,i.yF9� 9' 10'-4" 12'�3'-8"—+L' PRIOR TO PREPARATION OF FINAL AS-BUILT DRAWINGS.ANY VARIATION FROM APPROVED PLANS SHALL BE DOCUMENTED AND SUBMITTED TO THE BUILDING 2'-10" 6'-3" 5'-2"— - DEPARTMENT. NT TRUE 3'-11"_T_2'-4" 3'—�' 4' 1'-2'-4' 3'-T 3' 3'-8"—.� 3. ALL FLOOR PUNS,ELEVATIONS,SECTIONS AND DETAILS SHALL PARTITREPREIONS, OPENINGS, s•�W'F AS-BUILT CONDITIONS.INCLUDING STRUCTURAL MEMBERS PARTRIONS,OPENINGS, CEILING HEIGHTS,AND FINISHES 4. ALL MATERIALS AND CONSTRUCTION DETAILS SHALL CONFORM TO RCNYS CHAPTER 3 d/7/2026 FOR BUILDING PUNNING AND CHAPTER 7 FOR WALL COVERINGS AND INTERIOR FINISHES. REVISION LOG S ALL INTERIOR FINISH MATERIALS SHALL COMPLY WITH FLAME-SPREAD AND NO. REVISION (3•-0'x T-0•)l SMOKE-DEVELOPED INDEX REQUIREMENTS OF RCNYS TABLE R3029. 1 [!ALL NO= S. MINIMUM ROOM DIMENSIONS, CEILING HEIGHTS, AND HABITABLE SPACE REQUIREMENTS SHALL CONFORM TO RCNYS SECTIONS R304 AND R30S - 7. ALL DOORS,WINDOWS,AND SKYLIGHTS SHALL BE NFRC-LABELED AND INSTALLED IN UP a ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND CODE-APPROVED FLASHING AND WEATHER-RESISTANT BARRIERS PER RCHYS R609 AND R701 CLOSET _�� 8. STAIRS,HANDRAILS,AND GUARDS SHALL COMPLY WITH RCNYS R311 AND R312 FOR RISE,RUN,WIDTH,AND GUARD HEIGHT REQUIREMENTS BEOROOM01 9. FIRE-SEPARATION REQUIREMENTS BETWEEN GARAGES DWEWNG UNITS,AND ATTICS 10'-00'X10'-0d' / SHALL COMPLY WITH RCNYS R30Z INCLUDING FIRE RATED ASSEMBLIES AND C.G.OT-00• PROTECTED OPENINGS. 10. SMOKE ALARMS AND CARBON MONOXIDE DETECTORS SHALL BE INSTALLED AS O - REQUIRED BY RCRYS R314 AND R315 AND SHALL BE HARD-WIRED WITH BATTERY m TV/PLAYROOM LIVING ROOM c BACKUP AN D INTERCONNECTION WHERE REQUIRED. 08'-OB"X15'-00" 11'-DB'1(16'-08" IL THERMAL ENVELOPE ELEMENTS(INSULATION,AIR BARRIER.AND VAPOR RETARDER) CLG.OT-00" � CLG.09'-00' SHALL BE DOCUMENTED AND VERIFIED TO MEET ECCCNYS R402 MINIMUM / PERFORMANCE VALUES FOR CLIMATE ZONE 4. - 12. ALL ATTIC AND CRAWL SPACE VENTILATION SHALL COMPLY WITH RCNYS R806 AND RADII TO ENSURE ADEQUATE AIR CIRCULATION AND MOISIURE CONTROL 13. ALL ARCHITECTURAL OPENINGS FOR ELECTRICAL, PLUMBING, AND HVAC O m PENETRATIONS SHALL BE SEALED TO MAINTAIN THE CONTINUITY OF FIRE AIR O Z Z ® STORAGE GOWN AND MOISTURE BARRIERS. V——i 10'-WX06'-06' 0 14. ACCESSIBILITY FEATURES WHERE APPUCABLE,SHALL CONFORM TO BCNYS 2020 Z LLJ j CLG.09'-00' SECTION 1107 FOR RESIDENTIAL USE AND UNWEASAI DESIGN ELEMENTS, O _ RECOGNIZING THAT SINGLE-FAMILY HOMES ARE GENERALLY EXEMPT FROM ADA F 0 / REQUIREMENTS. Q p / 15. ALL EXTERIOR ELEVATIONS SHALL SHOW FINISHED GRADE LINES,ROOF HEIGHTS AND ~J EL-2 m EL-d MATERIAL TRANSITIONS IN COMPLIANCE WITH TOWN OF SOUTHOLD HEIGHT AND A006 (2 8 v4-10) A008 W U SETBACK REGULATIONS. 71 16. MECHANICAL, ELECTRICAL, AND PLUMBING FIXTURE LOCATIONS SHALL BE LL COORDINATED WITH ARCHITECTURAL DRAWINGS AND FIELD-VERIFIED FOR ASBUILT () ACCURACY.in O Z --'�r IT. ENERGY EFFICIENT LIGHTING AND APPLIANCES SHALL COMPLY WITH NEC 2020 0 O La BATH HOMEOFFlCE AND ECCCNYS ELECTRICAL EFFICIENCY REQUIREMENTS. F q aa'-0S_:l 1D•-09'Xar-00" CLG.DT-00' CLG.D9'-ff 9 18. ATTIC ACCESS AND CRAWL SPACE ACCESS OPENINGS SHALL BE PROVIDED IN z O ACCORDANCE WITH RCNYS R807 AND A408 AND SHALL BE CLEARLY DOCUMENTED ON J AS-BUILT DRAWINGS. m 19. ALL ARCHITECTURAL WORKAND FIELD MODIFICATIONS SHALL BE SUBJECT TO FINAL C/)XQ INSPECTION AND APPROVAL BY THE TOWN OF SOUTHOLD BUILDING DEPARTMENT Q W 2 PRIOR TO ISSUANCE OF CERTIFICATEOF OCCUPANCY. ao 2Q PMYLLCN RC0: -STUDSDS::T 2'a 51/2'd➢15'O.C. MUDROOM -INSULATION:R-19 WHITE PAPER-BACKED FIBERGLASS ROLL - 11-07 XO4-11' °O ,FRONT DECK DRAWINGTILTE (E)GROUND FLOOR PLAN #—2'-8"4—2'-II8"—X—T-8"—414--3'J2"4—3'—A 2l 3'_4 � 4--3�- "4—2'-8"4—2'-8" —T-e2"44'X- 6'-3" F-4" X—3'-8" # 12'-9" �`- CLIENT: HOME OWNER 35' LL DRAFTSMAN: RIFHAN REVIEWER: HE EL-1 PROJECT ID: 511 Ao05 DRAWING: MS-ZG-06-511 DATE: 07.04.2026 GROUND FLOOR PLAN DOC REF: AS-BUILT " FP-02 I SCALE:3/8"=1'-0" A 0 0 ARCHITECTURAL NOTES U L ALL ARCHITECTURAL WORK SHALL COMPLY WRN THE RESID-101.CODE OF NEW YORK STATE(RCNYS 2D20),BUILDING CODE OF NEW YORK STATE(BCNYS2020). STAMP ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE(ECCCNYS 2020), AND THE TOWN OF SOUTHOLD ZONING CODE(4290). 2. ALL EXISTING CONDITIONS,DIMENSIONS.AND MATERIALS SHALL BE FIELD-VERIFIED oFN � PRIOR TO PREPARATION OF FINAL AS-BUILT DRAWINGS ANY VARIATION FROM El-3 APPROVED PLANS SHALL BE DOCUMENTED AND SUBMITTED TO THE BUILDING _ A007 DEPARTMENT. 3. ALL FLOOR PLANS,ELEVATIONS,SECTIONS,AND DETAILS SHALL REPRESENT TRUE A'F 26' AS-BUILT CONDITIONS,INCLUDING STRUCTURAL MEMBERS,PARTITIONS,OPENINGS. CEILING HEIGHTS,AND FINISHES 13'-6" 3'-8" 1. ALL MATERIALS AND CONSTRUCTION DETAILS SHALL CONFORM TO RCNYS CHAPTER 3 IA7/202fi T-5" 2'_8^ 5'. FOR BUILDING PLANNING AND CHAPTER 7 FOR WALL COVERINGS AND INTERIOR "� FINISHES. REVISION LOG T-9"�{'�2'-8" 2'-8"�4'-9"--A�T-8" 2'-8"—X—4'-2° 5. ALL INTERIOR FINISH MATERIALS SHALL COMPLY WITH FUME-SPREAD AND NO. REVISION I I SMOKE-DEVELOPED INDEX REQUIREMENTS OF RCNYS TABLE R302.9. (2'-8'z4'-6) (1'.8"x 4'.0 (2-8'xd'-6') (Y-B'a4'-69 6. MINIMUM ROOM DIMENSIONS, CEILING HEIGHTS, AND HABITABLE SPACE REQUIREMENTS SHALL CONFORM TO RCNYS SECTIONS R304 AND R305. / 7. ALL DOORS,WINDOWS,AND SKYLIGHTS SHALL BE NFRC-LABELED AND INSTALLED IN CLOSET _ ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND CODE-APPROVED FLASHING AND WEATHER-RESISTANT BARRIERS PER RCNYS R609 AND R703. e 8. STAIRS,HANDRAILS,AND GUARDS SHALL COMPLY WITH RCNYS R311 AND R312 FOR RISE,RUN,WIDTH,AND GUARD HEIGHT REQUIREMENTS. BEDROOM03 9. FIRE-SEPARATION REQUIREMENTS BETWEEN GARAGES,DWELLING UNITS,AND ATTICS E. 13'-06^XIO'-05' SHALL COMPLY WITH RCNYS R302. INCLUDING FIRE-RATED ASSEMBLIES AND CLG.OT-001 _ PROTECTED OPENINGS 10. SMOKE ALARMS AND CARBON MONOXIDE DETECTORS SHALL BE INSTALLED AS v REQUIRED BY RCNYS R314 AND R315 AND SHALL BE HARD-WIRED WITH BATTERY BACKUP AND INTERCONNECTION WHERE REQUIRED. ILY ROOM / 11. THERMAL ENVELOPE ELEMENTS(INSULATION,AIR BARRIER,AND VAPOR RETARDER) DINING/FAM SHALL BE DOCUMENTED AND VERIFIED TO MEET ECCCNYS R402 MINIMUM OB-OYXILY ROOM CL0.XIS'-' © PERFORMANCE VALUES FOR CLIMATEZONE 4. 12. ALL ATTIC AND CRAWL SPACE VENTILATION SHALL COMPLY WITH RCNYS R806 AND R408 TO ENSURE ADEQUATE AIR CIRCULATION AND MOISTURE CONTROL 13. ALL ARCHITECTURAL OPENINGS fOR ELECTPoCAI, PLUMBING. AND HVAC m EL2 _ 30°WIDEHALLWAY DOWN - - - Eld PENETRATIONS SHALL BE SEALED TO MAINTAIN THE CONTINUITY OF FIRE,AIR O Z A006 ® ""\ A008 AND MOISTURE BARRIERS. ILL.J O 14. ACCESSIBILITY FEATURES,WHERE APPLICABLE,SHALL CONFORM TO BCNYS 2020 W O L SECTION 1107 FOR RESIDEN71F1 USE AND UNIVERSAL DESIGN ELEMENTS. 0 2RECOGNILNG THAT SINGLE-FAMILY HOMES ARE GENERALLY EXEMPT FROM ADARED ALL EXTERIOR. Q 115AlL EXTFRIOfl ELEVATIONS SHALL SHOW FINISHED GRADE LINES,ROOF HEIGHTS,AND wMATERIAL TRANSITIONSIN COMPLIANCE WITH TOWN OF SOUTHOLD HEIGHTAND YROOM 02 SETBACK REGULATIONS. 17(10'-016. MECHANICAL, ELECTRICAL, AND PLUMBING FIXTURE LOCATIONS SHALL BE G.O9'-00° COORDINATED WITH ARCHITECTURAL DRAWINGSAND FIELD-VERIFIED FOR AS-BUILT- ACCURACY. Q17. ENERGY EFFICIENT LIGHTING AND APPLIANCES SHALL COMPLY WITH NEC 2020 TliKRCMENAND ECCCNYS ELECTRICAL EFFICIENCY REQUIREMENTS. F. >7OT-09X05'-w, J G CLG.09'-00° BP Z' 18. ATTIC ACCESS AND CRAWL SPACE ACCESS OPENINGS SHALL BE PROVIDED INOACCORDANCE WITH RCNYS R807 AND Rd08 AND SHALL BE CLEARLY D�UMENTED ON m AS-BUILT DRAWINGS c 15 ALL ARCHITECTURAL WORK AND FIELD MODIFICATIONS SHALL BE SUBJECT TO FINAL f/)X INSPECTION AND APPROVAL BY THE TOWN OF SOUTHOLD BUILDING DEPARTMENT Q y°1 2 PRIOR TO ISSUANCE OF CERTIFICATE OF OCCUPANCY. I(2'-8'a4'-6') (3'-d's1'-fii I (2'-8'[4'-6yI #-4'-�/2' -P-8" 4'-A'-X-3,_4„-X-4' T_8„4-4,-4„ 7'-7Y2"II I7' I 5'-8- 6-2-------Y-2'-4" T-1" 26' DRAWING TILTE EL-1 A005 (E)FIRST FLOOR PLAN CLIENT: HOMEOWNER DRAFTSMAN: RIFHAN REVIEWER: HE PROJECT ID: 511 DRAWING: MS-ZG-06-511 DATE: 07.04.2026 FIRST FLOOR PLAN DOC REF: AS-BUILT FP-03 I SCALE:3/8"=1'-0" A003 ARCHITECTURAL NOTES L. ALL ARCHITECTURAL WORK SHALL COMPLY WITH THE TLAL CODE OF NEW YORK S YOPN STATE(RCNYS 2020),BUILDING CODE OF NEW YOAK STATE(0CNY52020), ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE(ECCCNYS 2020). STAMP AND THE TOWN OF SOUTHOLD ZONING CODE(5280). 2. ALL EXISTING CONDITIONS,DIMENSIONS,AND MATERIALS SHALL BE FIELD-VERIFIED �oF x4Tyy PRIOR TO PREPARATION OF FINAL AS-BUILT DRAWINGS.ANY VARIATION FROM n`dV"�W� APPROVED PUNS SHALL BE DOCUMENTED AND SUBMITTED TO THE BUILDING DEPARTMENT. EL-3 A0.07 3. ALL FLOOR PUNS,ELEVATIONS,SECTIONS,AND DETAILS SHALL REPRESENTTRUE OPENINGS. AS-BUILT CONDITIONS,INCLUDING STRUCTURAL MEMBERS,PARTITIONS,OPENINGS, CEILING HEIGHTS,AND FINISHES. sswM"' 4. ALL MATERIALS AND CONSTRUCTION DETAILS SHALL CONFORM TO RCNYS CHAPTER 3 AADY2026 FOR BUILDING PLANNING AND CHAPTER 7 FOR WALL COVERINGS AND INTERIOR ,p FINISHES. S ALL INTERIOR FIMSH MATERALS SHALL COMPLY WITH FLAME-SPREAD AND REVISION LOG SMOKE-DEVELOPED INDEX REQUIREMENTS OF RCNYS TABLE FM29 NO. REVISION I I1 71I J I� 6. MINIMUM ROOM DIMENSIONS, CEILING HEIGHTS, AND HABITABLE SPACE L ` L_F• III ;_I r ( I_ - ( _ REQUIREMENTS SHALL CONFORM TO RLNYS SECTIONS R304 AND R308. I r I- I r I I 11 I 7. ALL DOORS,WINDOWS AND SKYLIGHTS SHALL BE NFRC LABELED AND INSTALLED IN j_I' ( ( I 11 , 1,, I I -I(- 1, I I �7 I I - ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS AND CODE-APPROVED T I 1I_IIIIL�.I. l r �. I _� PUSHING AND WEATHER-RESISTANT BARRIERS PER RCNYS R609 AND 11A I IL I I ,I - - ,'- I J B. STAIRS,HANDRAILS,AND GUARDS SHALL COMPLY WITH RCNYS R311 AND R312 Poft ��L I L'JI 1.1 �,II RISE,RUN,WIDTH,AND IREMENHEIGHT REQUIREMENTS. r I �- I I I PfTCH,8:12- ^, I,1 9. FIRE-SEPARATION REQUIREMENTS BETWEEN GARAGES 01YEWNG UNITS,AND ATTICS L ;II1• SHALL COMPLY WITH RCNYS R302. INCLUDING FIRE-RATED ASSEMBLIES AND r I I14 IT I (( I F(I I-it I PROTECTED OPENINGS ) NSTALLED AS III' I I. 1 I I J 1 1 11 III I l0. E UIREDD KE BYMRCNYS R314 S AND BAND R35ON 0%AND SHALL IDE TBESHA96WIRED L BE IVATHBATTERY �r RE I-1 L(" I I II 11 I I l I I I C II J 11 BACKUP AND INTERCONNECTION WHERE REQUIRED. T. I I I I I 11. THERMAL ENVELOPE ELEMENTS(INSULATION,AIR BARRIER,AND VAPOR RETARDER) _I I I J I �-Iy I III III I J �I_I-1 f j I = SHALL BE DOCUMENTED AND VERIFIED TO MEET ECCCRYS R402 MINIMUM I 1 I I I�L I� �r 1,1 11 I��- ALLPER ATTIC ANDCE L SPACE CLIMATE r�_ I _ I I I T L _ 12. ALL ATTIC AND CRAWL SPACE VENTILATION SHALL COMPLY WITH RCNYS P806 ,IJ Ir, J I.. I IF'11 I-' AND R408 TO ENSURE ADEQUATE AIR CIRCULATION AND MOISTURE CONTROL N A006 I--- I �l I_II I i I_ I 11) 3= 13. ALL ARCHITECTURAL OPENINGS FOR ELECTRICAL, PLUMBING, AND HVAC e i 1 _ 1 PENETRATIONS SHALL BE SEALED TO MAINTAIN THE CONTINUITY OF FIRE,AIR �' ~ -- •� LJ} LLd AND MOISTURE BARRIERS. EL-2 ;_I 11 I I 1 1J.: >_/_ 1 I l A00d l/. ACCESSIBILITY FEATURES.WHERE APPLICABLE SHALL CONFORM TO RLNYS 2020 '�.J_I J _ ll I,1-d L11;;�<<I � Ij �llL lI 1JIII II L1 1 Lu IL1_ '''7 II ,rJ TII f SECTION 1107 FOR RESIDENTML USE AND UNIVERSAL DESIGN ELEMENTS Z LiJ O RECOGNIZING THAT SINGLE-FAMILY HOMES ARE GENERALLY EXEMPT FROM ADA 2 REQUIREMENTS. _I�11�I L�JIJ IL�Lf 1LI JlI ,I_11 Imo_: II f I I I 1S ALL EXTERIOR ELEVATIONS SHALL SNOW FINISHED GRADE LINES,ROOF HEIGHTS AND LI I L,�1 I L1. IL_ -);-I_I LI,u IJ U ILL II J1 J.I I� _ MATERIAL TRANSITIONS IN COMPLIANCE WITH TOWN OF SOUTHOLD HEIGHT AND z J Y �I Li I.I II II 11 1 1��1 II �..I II_I ILJ-Jl '1.11:L LJ .U.!i 11 I -Ui-LI l 1 7 - l6. MELHACK ANICAL,U ELECTRICAL. AND PLUMBING FIXTURE LOCATIONS SHALL BE u.1 ft l Ill 11,, L 1 .I_ I� IJ U l I Ii_�L l .L IL �ap II l COORDINATED WITH ARCHITECTURAL DRAWINGS AND FIELD OCA ION F SAS BUILT I.IL 11 11 II 'J-_I IYI J 1 L 1 t1 l '.IJi I L L I1J 1 Ll J I 1_1 L. ACCURACY. C-)IL 'I, L� -_I I 1 I I- Ll 1L1 J IJ I I 17. ENERGY EFFICIENT LIGHTING AND APPLIANCES SHALL COMPLY WITH NEC 2020 0 z It. I I I AND ECCCRYS ELECTRICAL EFFICIENCY REQUIREMENTS 0�w F IJ I.�'r ''J-IL.-I I i- Li 1 1_ l 1 T.L- 1 I� 1 Ll_.J Ll 111 I>�I I I L)rL.1 ItI�_�_) 11 JI U �LI�1 I ! `I PITCH 8:12 I 11.. LL IL L 1 I 11.1 11-�_iI I IH. ATTIC ACCESS AND CRAWL SPACE ACCESS OPENINGS SHALL BE PROVIDED IN J(�¢ J l ACCORDANCE WITH RCNYS R807 AND R408 AND SHALL BE CLEARLY DOCUMENTED ON Z 1111i;JI 1J 11 L11I1I 1I1 LLB, � L1U IL LI III Ll lJ L I AS-BUILT DRAWINGS. 1_ILLI-� I�u� _I 11��LL I i L LLL �I;`L 1 J, 19. ALL ARCHITECTURAL WORK AND FIELD MODIFICATIONS SHALL BE SUBJECT TO FINAL m C/� ( Li `iT I 1 I -I( INSPECTION AND APPROVAL BY THE TOWN OF SOUTHOLD BUILDING DEPARTMENT f/�X T1Ii1 I -Y PRIOR TO ISSUANCE OF CERTIFICATE OF OCCUPANCY. Q W 2 LLL� Ill I l 11 t r I l� _ l l 1 l I I I LLL L 1J 1 L L-L I I JAI_ L 1 i:__J J 4J._! ,. II' 1 II I I ,I 1 I II Ilil .;'PITCH 712 -I ��•_, .I II DRAWING TILTE rwilvi - rt L r� (E)ROOF PLAN 7_E:E::::3 LL1 CLIENT: HOMEOWNER A0.75 DRAFTSMAN: RIFHAN REVIEWER: HE PROJECT ID: 511 DRAWING: MS-ZG-06-511 DATE: 07.04.2026 ROOF PLAN DOC REF: AS-BUILT RP-04 SCALE:3/8"=1'-0" A004 ELEVATION NOTES 1. ALL EXTERIOR ELEVATIONS SHALL REPRESENT TRUE AS-BUILT CONDITIONS, INCLUDING FINISHED GRADES ROOF HEIGHT;WINDOW AND DOOR LOCATIONS.AND MATERIAL TRANSITIONS. STAMP 2. EXTERIOR WALL CONSTRUCTION,CLADDING,AND WEATHER BARRIERS SHALL COMPLY WITH RCNYS SECTIONS R703 AND R704 FOR WEATHER RESISTANCE,WATER 'oFxrwr MANAGEMENT,AND MATERIAL INSTALLATION 3. FINISHED GRADE ELEVATIONS SHALL 0E SHOW7l AND SNALL MATCH VERIFIED FIELD SURVEY DATA.ALL GRADES SHALL SLOPE AWAY FROM THE FOUNDATION AS REQUIRED BY RCNYS SECTION R401.1 g 4. MAXIMUM BUILDING HEIGHT SHALL CONFORM TO THE TOWN OF SOUTHOLD - ZONING CODE 0280).AND SHALL BE VERIFIED FROM AVERAGE GRADE TO THE HIGHEST POINT OF THE ROOF. 4/T/2D26 5. ALL ROOF ASSEMBLIES SHALL COMPLY WITH RCNYS CHAPTER 9 FOR MATERIALS, INSTALLATION, AND DRAINAGE REQUIREMENTS ROOF PITCH AND DRAINAGE REVISION LOG SLOPES SHALL BE CLEARLY INDICATED. TOP LEVEL 6. EXTERIOR DOORS,WANDOWS,AND SKYLIGHTS SHALL BE NFRC-LABELED AND NO. REVISION -------------------- INSTALLED WITH CODE-APPROVED FLASHING,SEALANTS,AND WEATHER-RESISTANT l21-06I OPENING DETAILS PER RCNYS R609 AND 11703. 7. EXTERIOR MATERIALS(SIDING,TRIM,MASONRY,STUCCO,OR PANEL SYSTEMS)SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER REQUIREMENTS AND RCNYS TABLE R7014 FOR FASTENING AND SUPPORT. S ALL EAVES,SOE TIS,AND FASCIA SHALL BE CONSTRUCTED W17H APPROVED MATERIALS AND PROPER VENTILATION WHERE REQUIRED PER RCNYS SECTION Ram CDLING JOISTTOP_________________ 9. ROOF AND WALL PENETRATIONS(VENTS FLUES,EXHAUST TERMINALS,ELECTRICAL '-06' MASTS)SHALL BE WEATHER-SEALED AND LOCATED AS SHOWN ON ELEVATIONS; SEPARATIONS FROM OPENINGS SHALL COMPLY WITH RCNYS MECHANICAL REQUIREMENTS. B M.JtL[�," 10. GUTTERS,DOWNSPOUTS,AND ROOF DRAINAGE COMPONENTS SHALL DISCHARGE AWAY FROM THE FOUNDATION TO APPROVED DRAINAGE AREAS OR DRYWELLS AS Y SHOWN ON THE SITE PLAN. tl 41 It. ALL ELEVATION MATERIALS AND FINISHES SHALL MATCH FIELD-CONFlRLED p CONDITIONS AND BE DOCUMENTED IN THE AS-BUILT DRAWINGS, INCLUDING i COLOR TEXTURE,AND MATERIAL TYPE C) FIRST FLOOR FF.E J _ - z W O O�:x l 0 W J v �lL LLJ< Z ® w O Jz¢ Z 9 O m F � Pn� AGROUII)FLUDIcn F_F.E -_-__--____ - - Q LLJ �P�07-W a N.G L y T [ DRAWING TILTE 7 ' BASEMEN F.F.E --- --------------------------------------------------- E FRONT ELEVATION -0r oo J _ _ e. *� EL-Ol CLIENT: HOME OWNER DRAFTSMAN: RIFHAN REVIEWER: H.E PROJECT ID: 511 DRAWING: MS-ZG-06-511 FRONT ELEVATION DATE: 07.04.2026 DOC REF: AS-BUILT EL-01 I SCALE:3/8"=1'-0" A005 ELEVATION NOTES 1. ALL EXTERIOR ELEVATIONS SHALL REPRESENT TRUE AS-BUILT CONDITIONS, INCLUDING FINISHED GRADES ROOF HEIGHTS,WINDOW AND DOOR LOCATIONS,AND MATERIAL TRANSITIONS STAMP L EXTERIOR WALL CONSTRUCTION,CLADDING,AND WEATHER BARRIERS SHALL COMPLY WTII RCNYS SECTIONS R703 AND R704 FOR WEATHER RESISTANCE WATER MANAGEMENT,AND MATERIAL INSTALLATION, 1 FINISHED GRADE ELEVATIONS SHALL BE SHOWN AND SHALL MATCH VERIFIED FIELD SURVEY DATA ALL GRADES SHALL SLOPE AWAY FROM THE FOUNDATION AS REQUIRED BY RCNYS SECTION 11013. ' 4. MAXIMUM BUILDING HEIGHT SHALL CONFORM TO THE TOWN OF SOUTHOLD 4 . ZONING CODE(§290),AND SHALL BE VERIFIED FROM AVERAGE GRADE TO THE HIGHEST POINT OF THE RDOF. 4/T/2D26 S ALL ROOF ASSEMBLES SHALL COMPLY WITH RCNYS CHAPTER 9 FOR MATERIALS, INSTALLATION, AND DRAINAGE REQUIREMENTS ROOF FOUR AND DRAINAGE REVISION LOG SLOPES SHALL BE CLEARLY INDICATED. *TOPLEVEL------------------- 6. EXTERIOR DOORS,WINDOWS,AND SKYLIGHTS SHALL BE NFRC-LABELED AND NO. REVISION T♦21'-061 INSTALLED WITH CODE-APPROVED FLASHING,SEALANTS AND YaTHER-REUSTANT OPENING DETAILS PER RCNYS R609 AND R701 7. EXTERIOR MATERIALS(SIDING,TRIM,MASONRY,STUCCO,OR PANEL SYSTEMS)SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER REQUIREMENTS AND RCNYS -- TABLE R703.4 FOR FASTENING AND SUPPORT. S. ALL EAVES SOFFITS AND FASCIA SHALL BE CONSTRUCTED WITH APPROVED MATERIALS AND PROPER VENTILATION WHERE REQUIRED PER RCNYS SECTION R806. CEILING 1015T TOP_______________ ____ 9. ROOF AND WALL PENETRATIONS(VENTS,FLUES EXHAUST TERMINALS,ELECTRICAL '-06' MASTS)SHALL BE WEATHER-SEALED AND LOCATED AS SHOWN ON ELEVATIONS SEPARATIONS FROM OPENINGS SHALL COMPLY WITH RCNYS MECHANICAL REQUIREMENTS 10. GUTTERS,DOWNSPOUTS.AND ROOF DRAINAGE COMPONENTS SHALL DISCHARGE AWAY FROM THE FOUNDATION TO APPROVED DRAINAGE AREAS OR DRYWELLS AS SHOWN ON THE SITE PLAN. A1-15111. ALL ELEVATION MATERIALS AND FINISHES SHALL MATCH FEED-CONFIRMED CONDITIONS AND BE DOCUMENTED IN THE AS-BUILT DRAWINGS, INCLUDING PRFil COLOR,TEXTURE,AND MATERIAL TYPE - rn ILL. �Z z FIRST FLOORF.F.E W O J - ,1r-00" ----------- ------------ O =--- .:,:.. c o 2m}y .I Z'--L Y LLI mu m2¢'� =li� OZ� o �O� o J C7 Z SEC c� ��GROUND FLOOR F.F.E _ _ c W= NcG a. - G.L _ +.1 I DRAWING TILTE ,y �BASEMENT F.F.E------- r' .07..�,--- ------------ ------------_--_---------- (E)LEFT ELEVATION CLIENT: HOMEOWNER DRAFTSMAN: RIFHAN REVIEWER: H.E PROJECTED: 511 DRAWING: MS-ZG-06-511 LEFT ELEVATION DATE: 07.04.2026 DOC REF: AS-BUILT EL-02 I SCALE:3/8"=1'-O" A006 ELEVATION NOTES 1. ALL EXTERIOR ELEVATIONS SHALL REPRESENT TRUE AS-BUILT CONDITIONS, INCLUDING FINISHED GRADES,ROOF HEIGHTS,WINDOW AND DOOR LOCATIONS,AND MATERIALTRANSITIONS STAMP Z. EXTERIOR WALL CONSTRUCTION,CLADDING,AND WEATHER BARRIERS SHALL COMPLY WITH RCNYS SECTIONS R703 AND R704 FOR WEATHER RESISTANCE WATER 4Eo� wA MANAGEMENT,AND MATERIAL INSTALLATION. 3. FINISHED GRADE ELEVATIONS SHALL BE SHOWN AND SHALL MATCH VERIFIED + FIELD SURVEY DATA ALL GRADES SHALL SLOPE AWAY FROM THE FOUNDATION AS z REQUIRED BY RCNYS SECTION R4013. R a. MAXIMUM BUILDING HEIGHT SHALL CONFORM TO THE TOWN Of SOUTHOLD ZONING CODE 0280).AND SHALL BE VERIFIED FROM AVERAGE GRADE TO THE HIGHEST POINT OF THE ROOF. A/7/2036 5. ALL ROOF ASSEMBLIES SHALL COMPLY WITH RCNYS CHAPTER 9 FOR MATERIALS, INSTALLATION, AND DRAINAGE REQUIREMENTS ROOF PITCH AND DRAINAGE REVISION LOG SLOPES SHALL BE CLEARLY INDICATED. TOP LEVEL 6. EXTERIOR DOORS,WINDOWS,AND SKYLIGHTS SHALL BE NFRC-LABELED AND NO. REVISION -------------------- INSTALLED WITH CODE-APPROVED FLASHING,SEALANTS AND WEATHER-RESLSTANT +21 OPENING DETAILS PER RCNYS R609 AND R7C3. 7. EXTERIOR MATERIALS(SIDING,TRIM,MASONRY,STUCCO,OR PANEL SYSTEMS)SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER REQUIREMENTS AND RCNYS TABLE R703A FOR FASTENING AND SUPPORT. S ALL EAVES,SOFFITS,AND FASCIA SHALL BE CONSTRUCTED WITH APPROVED MATERIALS AND PROPER VENTILATION WHERE REQUIRED PER RCNYS SECTION RSOS CEILING IOIST ...... MASTS) 9. ROOF AND WALL PENETRATIONS(VENTS FLUES EXHAUST TERMINALS ELECTRICAL -0fi" TOP MASTS)SHALL BE WEATHER-SEALED AND LOCATED AS SHOWN ON ELEVATIONS: SEPARATIONS FROM OPENINGS SHALL COMPLY WITH RCNYS MECHANICAL REQUIREMENTS IO GUTTERS,DOWNSPOUTS AND ROOF DRAINAGE COMPONENTS SHALL DISCHARGE AWAY FROM THE FOUNDATION TO APPROVED DRAINAGE AREAS OR DRYWELLS AS SHOWN ON THE SITE PLAN. / O 11. ALL ELEVATION MATERIALS AND FINISHES SHALL MATCH FIELD-CONFIRMEO / CONDITIONS AND BE DOCUMENTED IN THE AS-BUILT DRAWINGS INCLUDING COLOR,TEXTURE,AND MATERIAL TYPE ® / O m Z Z FIRSTFLOORF.F.E W p F Nam, W00 �lL F- r- / O 0> / / 9 E O m Ncn J X Q +,GGROUNDFLOORF.F.E———————— ¢W= aOT-00•_____ 1 j DRAWING TILTE BAS QOENT F.F.E--------� A ----- -----_-------_------ _ --------_-----_------- E)REAR ELEVATION EL-03 CLIENT: HOMEOWNER DRAFTSMAN: RIFHAN REVIEWER: HE PROJECT ID: 511 DRAWING: MS-ZG-06-511 REAR ELEVATION DATE: 07.04.2026 DOC REF: AS-BUILT EL-03 I SCALE:3/8"=1'-0" A007 ELEVATION NOTES L ALL EXTERIOR ELEVATIONS SHALL REPRESENT TRUE AS BUILT CONDITIONS, INCLUDING FINISHED GRADES.ROOF HEIGHTS,NRNDOW AND DOOR LOCATIONS,AND MATERIAL TRANSITIONS. STAMP 2. EXTERIOR WALL CONSTRUCTION,CLADDING,AND WEATHER BARRIERS SHALL COMPLY WITH RCNYS SECTIONS R703 AND R704 FOR WEATHER RESISTANCE WATER vxcq. MANAGEMENT,AND MATERIAL INSTALLATION. rho ati d."�°.0 1 FINISHED GRADE ELEVATIONS SHALL BE SHOWN AND SHALL MATCH VERIFIED FIELD SURVEY DATA ALL GRADES SHALL SLOPE AWAY FROM THE FOUNDATION AS REQUIRED BY RCNYS SECTION R401.1 i 4. MAXIMUM BUILDING HEIGHT SHALL CONFORM TO THE TOWN OF SOUTHOLD q '^++^ , ZONING CODE H 280).AND SHALL BE VERIFIED FROM AVERAGE GRADE TO THE HIGHEST POINTOFTHERDOF. VT/2D26 5. ALL ROOF ASSEMBLIES SHALL COMPLY WITH RCNYS CHAPTER 9 FOR MATERIALS, INSTALLATION, AND DRAINAGE REQUIREMENTS. ROOF PITCH AND DRAINAGE REVISION LOG SLOPES SHALL BE CLEARLY INDICATED. *TOP LEVFl-------------------- 6. EXTERIOR DOORS,WINDOWS,AND SKYLIGHTS SHALL BE 14FRC-LABELED AND NO. REVISION T♦21'-06I' INSTALLED NSTA G DET�CODE-APER PPROVED LASHING.SEALANTS,AND WEATHER-RESISTANT OPENI7. EXTEPoOR MATERIALS(SIDING,TRIM,MASONRY,STUCCO,OR PANEL SYSTEMS)SHALL BEINSTALLED IN ACCORDANCE WITH MANUFACTURER REQUIREMENTS AND RCNYS TABLE R703.4 FOR FASTENING AND SUPPORT. B. ALL EAVES,SOFFITS,AND FASCIA SHALL BE CONSTRUCTED WITH APPROVED MATERIALS AND PROPER VENTILATION WHERE REQUIRED PER RCNYS SECTION 118M. CEILING IOLRT TOP 9. ROOF AND WALL PENETRATIONS(VENTS.FLUES,EXHAUST TERMINALS.ELECTRICAL .211 -- — pp, MASTS)SHALL BE WEATHER-SEALED AND LOCATED AS SHOWN ON ELEVATIONS: SEPARATIONS FROM OPENINGS SHALL COMPLY WITH RCNYS MECHANICAL REQUIREMENTS. l4 GUTTERS,DOWNSPOUTS AND ROOF DRAINAGE COMPONENTS SHALL DISCHARGE AWAY FROM THE FOUNDATION TO APPROVED DRAINAGE AREAS OR DRYWELLS AS SHOWN ON THE SITE PLAN. p 11. ALL ELEVATION MATERIALS AND FINISHES SHALL MATCH FIELD-CONFIRMED CONDITIONS AND BE DOCUMENTED IN THE AS-BUILT DRAWINGS INCLUDING COLOR,TEXTURE AND MATERIAL TYPE B o+ O z LL_J 2. J FIflST FLOOR Ff.E O LaJ= �O 1--•}An ZJY uj X �LJ_ o ® OZZ a O O> a a J C7 Z 9 mZ0 y xxy3 �GflOUND FLOOR FF.E a0P-0T----- `Y taLpG.L L I 1 DRAWING TILTE . 1 1 �BASEMENT F.FF ,1____ ______________ __ (E)RIGHT ELEVATION ----------------------------1 n _ _ _ _ _-- EL-04 CLIENT: HOMEOWNER DRAFTSMAN: RIFHAN REVIEWER: HE PROJECT ID: 511 DRAWING: MS-ZG-05-511 DATE: 07.04.2026 RIGHT ELEVATION DOC REF: AS-BUILT EL-04 I SCALE:3/8"=1'-O" A008 MAINHOUSE ROOF 4pTRRUROOF n 4-TRRUROOF n ZEN DESIGN Y a Y I I I I POST OFFICE SDR 88 CUTCHOGUE.NY 11935 KITCHEN --- BATH ^ TT , PHONE:G315L9.8589 --------------- I -- I 1 teupYrum.rp�rnrunyw..yripe I ------V2 y .p m n.arp�m....•mre.amro. I , I � � o-,nonn ..utAriedrrn�i.wm nia�m°imo..,e�." I I j � I I uYNmLrraYnYM cnabow urO Mm.vn I I , , I I m.p r°rra.c.mntl..sa+anr..ror I I , , I I ��.e.prnpanoraunmuruiupn.. 1112 V IV2 V I I I I LAV LAV NO. ISSUE DATE WASH i IUB jw.c.. OIL lax xICX1L25 SECOND FLOOR 19/2° �W] MACH � I I � 2° 2°w 2' 2` 2° 1 I I I I BATH 1 ---------------- I -, I I ftFD Ape I LAVNfCyO`sT��.t O.A.L W.C. N 2 1STROOR 04442," P� yo F OF NFL TO APPROVED SANITARY DISPOSAL SYSTEM 645 HAMILTON AVE MATTTTUCK NY 11952 SCTMY S000-140-2-i BASEMENT SCALE NTS DATE: 03.0226 DRAWN BY: Z.E.N. RISER DIAGRAM RISER DIAGRAM SCALE:NTS AA v 9 Dq5 �(o A wlff� i r k' � ..a`. ir `I 1.44 ` 'tea 4 w 1 7 r ` ` Y ���7 //�,� ri.: F;t H'4' !r. R1 ►1 .5ti3 t '*e; a l�M1 .:.ti. ......�n^�:. �a�� �� '�Y �� ���' �.%a. \ � `�f � i e ,� c� a � t 1 `� - _ _ _ � �, { �i_x 'M - . 1.. ���� � '.� 1 ,�I l i j �' i 1 • ;�► ret ,, � , �a: ,_ / 7 .� ' / � ' � { t a �:-'; �:. x �. � ., 4? a� � F r � � f ' �� :9 r .. ._ � ._ - _ ... L 1. 3' .. , i `r f fjjj i ,,�► ,�"` #. � ! ,,