Loading...
HomeMy WebLinkAbout52761-Z apf Soo}yO!° Town of Southold * * P.O. Box 1179 410 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47020 Date: 05/04/2026 THIS CERTIFIES that the building SINGLE FAMILY DWELLING-ALTERATION Location of Property: 1760 Crown Land Ln Cutchogue, NY 11935 Sec/Block/Lot: 102.-7-8 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 03/12/2026 Pursuant to which Building Permit No. 52761 and dated: 03/16/2026 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Boiler replacement to existing single family dwelling as applied for. The certificate is issued to: Mordechai Nemes Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: PLUMBERS CERTIFICATION: George Schoenwaelder Jr 3/6/2026 Lhona Signatur ho�*0VSO& TOWN OF SOUTHOLD BUILDING DEPARTMENT ' SOUTHOLD, NY �o BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52761 Date: 03/16/2026 Permission is hereby granted to: Eric Klodnicki PO BOX 722 Cutchogue, NY 11935 To: Replace boiler(and change fuel source)at existing single family dwelling as applied for. Premises Located at: 1760 Crown Land Ln, Cutchogue, NY 11935 SCTM# 102.-7-8 Pursuant to application dated 03/12/2026 and approved by the Building Inspector. To expire on 03/15/2028. Contractors: Required Inspections: Fees: Single Family Dwelling- Alteration $250.00 CO-RESIDENTIAL $3.00.00 Tot 350.00 Build ng Inspector Town Hall Annex hi 54375 Main Road Telephone(631)765-1802 P.O. Box 1179 .> Southold, NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: 3 (n Building Permit No. 5��(0 Owner: /Vomels (Please print) Plumber:C-9envdrr (Please print) I certify that the solder used in the water supply system contains le han 2/10 of 1% lead. (Plum ers Si ature) Sworn to before me this day of 20 0 Notary Public, Q �aA MARZ1077 0 Nt)TARY PUBLIC,STATE OF NEW YORK f40.OI MA4871585 I QUALIFIED I.N.SUFFOLK COUNTY MY COMMISSION EXPIRES SEpTEMBER 22,20 OF 50Ulyo TOWN OF S LD BUI ING DEPT. 31-765-1802 IN - ON [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ FINALoi/e2 [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: CCeS� • ��aGl� . DATE 7 .�3�a� INSPECTOR OF SOlIT,�°�o # * TOWN OF SOUTHOLD BUILDING DEPT. MUM, 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ FINALl [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: �r\54 ( 1 0�- C.0 DATE INSPECTOR TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax(631) 765-9502 hLtps://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only 1 PERMIT NO. k-4509 7121 121 Building Inspector. i a� �= t• 'J li I�Catrs ►s iti r t bye a cep 1A�her tEieffA�pp cants r��i fh �ir�ner aci MAR 2026 'Al Date: s ! Name: SCTM#1000- .Project Address: Phone#: 3 _T IC; Email: Mailing Address: � z A„ax:.✓.,..,,,,.k.. `.rh s.�.>���, E�� ��y� .�+���f d `ram+�r d�� xl3�z✓� .� � 2`"sn 4�$f�.�� � 'r � ����� h Y,. =� ���� `� Name: Mailing Address: Phone#: Email: ',✓ ^- =bn:b�z.•r .�..,H....», k».H�.,,._,.x,3d n.•.,• T,N�„g„s,,�,. ,. �, ��:a.��'�. 2r aT�,'Z�`�fi,�,�....,.tea.,_:�-ram'> ...:,,,... -"'�';c6a.._,.,""i'ca ...a k..,: r, s.�...�'1,� _�#,��� Name: Mailing Address: Phone#: Email: x,�"dw 1+x'+r�Y ''�4 �';�,�"`- ,`&� � � .X:�,Y Yfr +«r✓o;. s - � `�! E'°' .�,i✓.� � }"��'.l•.:..r-� m`.�t--r� - � .�. 7 �r 7 `r. .�.?=3«<.+r..a -a^ ,...��'�,�.. .e�d ;w>;X.,.,,,,, ry ._,.z.: ....,e:+:,:..,.a,. ..u�,.:,�_�.-_.-a:.,..,..e+.,�:,.ra.l-s< in, h_.���. .ms •k._ ?�, Name: _ �• ..... _C�'��c. e_S� _�ev_ia�a e_�e.,r_�._____._ �e_._ �er�,�cQ.e_,.C�e ..__.....��►__. _''.. __ -. .. .mac... .. . ......... ... . Phone#61�- qpq _ Email �' «"3`�f��� t'•^Y'1`F'�rC 4z� fi ,t p +' Sw'i-'2�, x a:+�'�*{" *#:>" a�Y�Xh"d �f£ '+` 9 n... +' n, � ..�3' ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: Will the lot be re-graded? ❑Yes El No Will excess fill be removed from premises? ❑Yes LINO 1 WOWS use of,pob#ent {titdrided use.of property:: Zone or use district itt which Op Isas is situated: ,Are there any cauenants and:restrictions w:th respect.fo this property? es o 1F YIS,PRaVfi3Ek COPY. Appiication Submttt. RY nt name{ �... authorized Ag ent. Clowner Signature of App1(cant; a.... MARt�i MARZO M0... . Si'A1�E DE NEifV:lldi ); Ai4Tfi R1BkiG STA'E 0 fYtiRK iEf:- t58S: 4;OLit�FF'Y, 100PNTYOt= �u.-f���7 A!�fi}�tfiiElfP�S�i2� :, being,duiy sworn,deposes and s. that(s)he.is the applicant . ... . {.Nerve., f individual signing Ortractj:above'named (S)he isthe 4 , (Ooritract+�C,A�getyt,:Gc�rpora��Officer,etcj: of said owner cr ouvners,and is duiyr:authorized to;perforri or'have=performed the said work aril to make and file this appiicat3on,that aH skateiriai f cont trier in this application are:trui=to tt�e best of kips%her,:krigv+itedge and belief.;aad that the wont a tilt be Odbftesi iri the rr artnersez forth iri the appi cation it herex ith. Sinrn'.°before:rite tt;t Notary Pubic PR3Ef'[ C:a01f .AUTiORZATtf}N '(Where e,,applicant is not the'cwrier) do hereby,authoize a-�r.:�. ��o .� J'd tc-applyon My.beh tp theF7owflr of.SouthQld t3uttding Departmentfor approval as described herein;: ----- _._. 315 Owner`s Signature O Naiyic Litoaqttn yui naPliuisfssbtieia�it>tnr i nEcx S oi ttanafoeR oEf t D.,ti 3tA1Print.Qvmes Nene n -County awes Ju APPROVED AS NOTED DAT B•P# 69FEE � �CCUPANC OR NOTIFY B DEPARTMENT AT USE IS U N LAW F U L OLLOWING2INSPECTIONS:FORTHE WITHOUT CERTIFICATE 1. FOUNDATION FOR POURED CONOCRETQE REQUIRED OF OCCUPANCY 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE&TOWN CODES AS REQUIRP AND CONDITIONS OF SOUI}I 70WNZBA sOuD DTOWNFIANNING BOARD SOMiOLD TOWN TRUSTEES N.Y.S.DEC eucr .$le wl I d SOUTHOLO HM XHD Dimensions Ratings DHW flow rates v" Navien Condensing Boiler DHW DHW Flow Rates GPM(Um) • Overhead view 9 9 9s OtherSpecifications p ,• Model Heath Heating Ratio NetAHRI TRem HCB 190/OBOH NCB 240/110H NCB-250/150H cje8n "`°4 Number, H�n9 Water °F(°c) NCB-1901080H NCB-240/130H T (BTU/Iq dC'P""ty. Rating, AFUEt Water ConnectionstieMax ) Wate; (%) Pressure (Supply, Return) 35(19) 8.2(31.1) 10.4(39.5) 10.8(40.9) IBN� 40(22) 7.2(27.3) 9.0(34.1) 9.5(35.8) s NCB-190/060H 11,000 60,000 1 56,000 49,000 45(25) 6.4(24.2) 7.9(30.0) 8.4(31.8) van+• 'i NCB•190/OSOH 11,000 80,000 4�OO 64,000 00110,00010 i 50(2B) 5.8(21.8) 7.2(27.3) 7.6(28.6) r� NCB 240/110H 13,0 2,000 55(31) 5.2(19.8) 6.6(25.0) 6.9(26.0) NCB-240/130H 1 13,000 130,000 120,000 104.000 60(33) 4.8(18.2) 6.0(22.7) 6.3(23.8) 1 Front View NCB-250/150H 1 14,000 150,000 1 138.000 120,000 j 67(37) 4.3(16.3) 5.4(20.4) 5.6(21.4) 'Ratings are the same for natural gas models converted to propane use. 70(39) 4.1(15.6) 5:1(19.3) 5.4(20.4) 3 Based on U.S.Department of Energy(DOE)test procedures. 77(43) 3.7(14.2) 4.7(17.8) 4.9(18.6) 3 The net AHRI water ratings shown are based on a piping and pickup allowance of 1.15.Consult Navien before 9 p p 9 p p 3.6 selecting a boiler for installations having unusual piping and pickup requirements,such as intermittent system 80(44) (13.6 ) 4.5(17.0) 4.7(17.9) I; operation,extensive piping systems,etc. �i 85(47) 3.4(12.8) 4.2(15.9) 4.4(16.8) Navien Condensing Boiler 90(50) 3.2(12.1) 4.0(15.1) 4.2(15.9) Other Domestic Hot Water Specifications • I� Domestic Not Wafer Ratings 100(56) 2.9(10.9) 3.6(13.6) 3.8(14.3) �I Input Ratings Water Row Rate DHW II Model (BTU/){) Minimum 45°F(25°L7 Connection Sae ,I Number Pressure Flow Rate Temp Rise Temp settings Min Max PSI GPM(Um) GPM(Um) Supply petum OO NCB-190/060H I' 10,700 160,000 6.4(24.2) Temperature NCB-190/080H Fitem Range Remarks NCB-240/110H 15-150 0.5 314" I 3/4" I F(°c) NCB-240/130N 13,300 199.900 (1.9) 7.9(30.0) NPT NPT 77-185 Actual supply and return Space Supply (25-85) temperatures vary Supply connections NCB-250/150H 14,000 210,000 8.4(31.8) I 0 Heating Return 68-158 depending on the selected, `r Q (20-70) outdoor reset curve. _:.. Specifications DHW (30-60) Specifications . NCB-190/Ds9H NCB2ann10H Model transition Item NCB-1901080H NCB-240/130H NCB 250/150H Dimensions 17.3"W x 29.3"H x 12.8"D Discontinued New j NCB-E NCB-H s•per" Boiler Empty 87lbs(40 kg) 96 Ibs(44 kg) rw M weight NCB-15BE NCB-190/060H 9 With water 93 Ihs(42 ka) 1021bs(46 kg) DHW:12,000-120,000 BTU/H DHW:10,700-160.000 BTUiH pMKn°° Installation type Indoor wall-hung HTG:60,000 BTU/H HTG:60.000 BTUIH see Pressure Relief Valve A"apter 0314• Venting type Forced draft direct vent NCB-18OE NCB-190/080H j Q A rintake m 3 DHW:14,000-150,000 BTU/H DHW:10.700-160.000 BTU/H Ignition Electronic ignition HTG:80,000 BTU/H HTG:80.000 BTU/H Exhaust 4)1' 0 Heating Supply m i• Natural gas supply pressure 3.5"to 10.5"WC NCB-210E NCB-2401110H ®DHW Hot Wateroutiet 03r4• (from source) DHW:18,000-180,000 BTU/H DHW:13,300-199.900 BTWN Q Gas Supply Inlet m3ra HTG:100,000 BTU/H HTG:110,000 BTU/H Propane gas supply pressure ®OHW Cold Water Inlet x 3r4• from source 8.0"to 13.5"WC ( ) N NCB-240/130H Q Avro Feeder Inlet(make-up up water m vx D ;18 000-199 TU/H DHW:13,300-199,900 BTU/H i 0 Condensate Outlet m rn Natural gas manifold pressure 0.01"WC to 0.06"WC to 0.06"WC to HT : 0 BTU/H HTG:130,000 BTUM 0 Heating Ream+ m t• -0.31"WC -0.24"WC -0.26"WC Propane gas manifold pressure -0.04"WC to -0.06"WC to -0.06"WC to t . -0.33"WC -0.26"WC -0.28"WC NCB-250/150H Gas connection size 3/4"NPT DHW:14,000-210.000 BTU/H HTG:150.000 BTU/H Power Main supply 120V AC.6OHz supply Maximum power Up to 15 amperes consumption Materials Warranty Casing Cold-rolled carbon steel • Heat exchangers Stainless steel Residential Single Family Use Only 2"or 3"PVC,CPVC,approved polypropylene I Heat exchanger 10 year I Exhaust 2"or 3"special gas vent type BH(Class III,A/B/C) 2"or 3"stainless steel Parts' 5 year Venting 2"or 3"PVC,CPVC,polypropylene Labor 1 year Intake 2"or 3"special gas vent type BH(Class III,A/B/C) -includes OHW Flat plate HX. 2"or 3"stainless steel Navien reserves the right to change specifications at any time without Vent clearance 0"to combustibles prior notice.Please refer to www.Navienlnc.com to verify you have the Flame Rod,APS,Ignition operation detector,water temperature high most current information. Safety devices limit switch,exhaust temperature high Iirp G ,water pressure sensor,burner high limit fusetartR'sta tal Itioation detector O Navien Inc., 20 Goodyear, Irvine,CA 92618 800-519-8794 navieninc.com Navien Canada, Inc. 555 Hanlan Rd., Unit 7 Vaughan, ON L4L 4198 800-519-8794 navieninc.ca MNavieN T H E L E A D E R I N C O N D E N S I N G T E C H N O 'L O G Y NCBH-BRO01-2306 ©2023 Navien Inc.