HomeMy WebLinkAbout53125-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 53125 Date: 07/15/2026 Permission is hereby granted to: Christopher diBonaventura 27 Suffolk Rd Chestnut Hill, MA 02467 To: Install a generator accessory to an existing single-family dwelling as applied for per manufacturers specifications. Premises Located at: 330 Ettrick St, Fishers Island, NY 06390 SCTM#9.-12-5 Pursuant to application dated 06/22/2026 and approved by the Building Inspector. To expire on 07/14/2028. Contractors: Required Inspections: Fees: GENERATOR $125.00 CO Accessory $100.00 Total S225.00 Building Inspector sFO4 TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https-//'www,souttioldtownny.gov Date Received APPLICATION FOR BUILDING PERMI�T EC EE VE For Office Use Only PERMIT NO. 5 Vl Building Inspector: /L/ Applications and forms must be filled out in their entirety. Incomplete Building DepOrtment applications will not be accepted. Where the Applicant is not the owner,an Tcrw,l of`c"'t�tbold Owner's Authorization form(Page 2)shall be completed. Date:06-18-26 OWNER(S)OF PROPERTY: Name:Christopher and Ellen diBonaventura SCTM# 1000-Section 009, Block 12, Lot 5 Project Address:330 Ettrick Ave Phone#:617-818-7607 Email:christopher.dibonaventura@gmail.com Mailing Address:2 Knowles St. Newton Center, MA 02459 CONTACT PERSON: Name:Jay Roarke Mailing Address:PO Box 447 Fishers Island, NY 06390 Phone#:631-788-7919 Email:jay@bdrrusa.com DESIGN PROFESSIONAL INFORMATION: Name:. Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name:BD Remodeling & Restoration Mailing Address:PO Box 447 Fishers Island, NY 06390 Phone#:631-788-7919 Email:jay@bdrrusa.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other Stand-by generator $50,000.00 Will the lot be re-graded? ❑Yes WNo Will excess fill be removed from premises? Dyes RNo 1 PROPERTY INFORMATION Existing use of property:Single Family Residential Intended use of property:Single Family Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R_80 this property? ❑Yes WNo IF YES, PROVIDE A COPY. El Check Box Aber Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted R prin e) Sfl`? J�opjTe Ve RAuthorized Agent El Owner Signature of Applicant: Date: 06-18-26 STATE OF NEW YORK) SS: COUNTY OF Suffolk County ) Jay Roarke being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent, Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith,. � w�wr+�"� ►a,, �* tip, Sworn before me this . .. day of Yl 20 Notary Public ?p za .."' . Fly l l "' l l 1.�.,IN m l rnualified in sutiolk Couniy ... l tnta ushllc-siate ai Iw Y�zdlt , (Where the applicant is not the owner) No,01DR6350454 Rey Cojnjffmissjwo Exptias November 07,2028 �y a �� al residing at �do hereby authorize ra�k�apply on y b d dw f Sou of ui ing Departm t for approval as described h rein, x1le Owner's Signature,1 Date N� RISTO+P" CA% �o►.�yEu,u�zq Print Owner's Name 2 4 c KOHLER. Generators Model: 48 RC LC Multi-Fuel LPG/Natural Gas Standard Features • The generator set and its components are prototype-tested, factory-built, and production-tested. • The generator set accepts rated load in one step. • A premium 5-year/2000-hour limited warranty covers all systems ^ `—.• `= - and components. v _. • Quick-ship(QS)models with selected features are available. See your dealer for details. • GFCI service outlet installed on the junction box. • RDC2 Controller o One digital controller manages both the generator set and transfer switch functions(with optional Model RXT ATS). o Designed for today's most sophisticated electronics. o Electronic speed control responds quickly to changing demand. The Kohler® Advantage g o Digital voltage regulation protects your valuable electronics • High Quality Power from harmonic distortion and unstable power quality. Kohler home generators provide advanced voltage o KOHLER Energy Management System for remote monitoring and frequency regulation along with ultra-low levels of is included with the generator. harmonic distortion for excellent generator power • Engine Features quality to protect your valuable electronics. o Powerful and reliable Kohler 6.2L liquid-cooled engine o Electronic engine management system. • Fast Response o Simple field conversion between natural gas and LP vapor Kohler's Fast-Response®X excitation system delivers fuels while maintaining emission certification.(Optional dual excellent voltage response and short-circuit capability fuel automatic changeover kit is available.) using a rare-earth permanent magnet(PM)-excited • Innovative Cooling System alternator. o Electronically controlled fan speeds minimize generator set • Quiet Operation sound signature. Kohler home generators provide quiet, neighborhood- • Approved for stationary standby applications in locations served friendly performance. by a reliable utility source. • Premium 5-year/2000 hr Limited Warranty Included • Certifications Kohler generator is known for extraordinary reliability o The 60 Hz generator set engine is certified by the and performance.Kohler's premium limited warranty Environmental Protection Agency(EPA)to conform to the covers parts,labor,and travel for the full warranty New Source Performance Standard(NSPS)for stationary period. spark-ignited emissions. • Aluminum Enclosure o cUL/UL listing,CSA certification standard are available. Attractive aluminum enclosure allows installation as o Accepted by the Massachusetts Board of Registration of close as 18 inches from your home or small business. Plumbers and Gas Fitters. Optional 291 kph(181 mph)wind-load-rated o Meets NFPA 37 requirements for 18 in.offset for installation. enclosure door kit is available for field installation. Generator Set Ratings Standby Ratings Standby Ratings Natural Gas LPG Line Circuit Breaker Alternator Voltage Ph Hz kW/kVA Amps kW/kVA Amps Amps Poles 120/240* 1 60 44/44 184 44/44 184 — — 120/208 3 60 48/60 167 50/62 174 175 3 4P7BX 127/220* 3 60 48/60 158 50/62 165 — — 120/240 3 60 48/60 145 50/62 151 150 3 277/480 3 60 48/60 73 50/62 76 80 3 4Q7BX 120/240 1 60 48/48 200 48/48 200 200 2 * Voltage configuration not available from the factory.Field-adjustable by an authorized service technician. t 50 Hz options are available.Contact your Customer Service representative. RATINGS:All three-phase units are rated at 0.8 power factor.All single-phase units are rated at 1.0 power factor.Standby Ratings.,Standby ratings apply to Installations served by a reliable utility source.The standby rating is applicable to varying loads for the duration of a power outage.There is no overload capability for this rating.Ratings are In accordance with ISO-8528-1 and ISO-3046-1.Obtain technical Information bulletin TIB-101 for ratings guidelines,complete ratings definitions,and site condition derates.The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever.Availability is subject to change without notice.Contact your local dealer for availability. G4-306 (48RCLC) 4/26e Plrehlko Alternator Specifications Specifications Alternator . The unique Fast-Response®X excitation system delivers Manufacturer Kohler excellent voltage response and short-circuit capability Type 4-Pole,Rotating Field using a rare-earth, permanent magnet(PM)-excited Exciter type Brushless,Rare-Earth alternator. Permanent Magnet . Brushless,rotating-field alternator. Leads:quantity,type 4Q76X 4,120/240 . NEMA MG1, IEEE,and ANSI standards compliance for 4P7BX 12,Reconnectable temperature rise and motor starting. Voltage regulator Solid State,Volts/Hz • Sustained short-circuit current of up to 300%of the rated Insulation: NEMA MG1 current for up to 10 seconds. Material Class H . Sustained short-circuit current enabling downstream circuit Temperature rise 130°C,Standby breakers to trip without collapsing the alternator field. Bearing:quantity,type 1,Sealed . Self-ventilated and dripproof construction. Coupling Flexible Disc Amortisseur windings Full • Windings are vacuum-impregnated with epoxy varnish for Voltage regulation,no-load to full-load t1.0%RMS dependability and long life. Unbalanced load capability 100%of Rated Standby • Superior voltage waveform from a two-thirds pitch stator Current and skewed rotor. One-step load acceptance 100%of Rating . Total harmonic distortion(THD)from no load to full load Peak motor starting kVA: (35%dip for voltages below) with a linear load is less than 4%. 480 V,400 V 4P7BX(12 lead) 180(60 Hz) 240 V 4Q76X(4 lead) 113(60 Hz) Application Data Engine Exhaust Engine Specifications 60 Hz Exhaust System 60 Hz Manufacturer Kohler Exhaust manifold type Dry Engine:model,type KG6208 6.2L Exhaust flow at rated kW,m3/min.(cfm) 16.4(580) Natural Aspiration Exhaust temperature at rated kW,dry Cylinder arrangement V-8 exhaust,"C(7) 649(1200) Rated rpm 1800 Maximum allowable back pressure,kPa(in.Hg) 10.2(3.0) Displacement,L(cu.in.) 6.2(378) Exhaust outlet size at engine hookup,mm(in.) 76(3.0)OD Bore and stroke,mm(in.) 101.6 x 95.25(4.00 x 3.75) Fuel Compression ratio 10.5:1 Max.power at rated rpm,kW(HP) 77.0(103) Fuel System Cylinder head material Cast Aluminum Fuel type LP Gas or Natural Gas Piston type and material High Silicon Aluminum Fuel supply line inlet 1 in.NPT Crankshaft material Cast Iron Natural gas fuel supply pressure,kPa Valve(exhaust)material Forged Steel (in.H20) 1.2-2.7(5-11) Governor type Electronic LPG vapor withdrawal fuel supply Frequency regulation,no-load to pressure,kPa(in.H2O) 1.2-2.7(5-11) full-load Isochronous Fuel Composition Limits" Nat.Gas LP Gas Frequency regulation,steady state t1.0% Methane,%by volume 92 min. — Frequency Fixed Ethane,%by volume 4.5 max. — Air cleaner type Dry Propane,%by volume 1.0 max. 87 min. Engine Electrical Propene,%by volume 0.1 max. 5.0 max. Engine Electrical System C4 and higher,%by volume 0.3 max. 2.5 max. Sulfur,ppm mass 25 max. Ignition system Electronic Lower heating value, Battery charging alternator: MJ/m3(Btu/ft3),min. 33.2(890) 84.2(2260) Ground(negative/positive) Negative Volts(DC) 12 " Fuels with other compositions may be acceptable.If your fuel is Ampere rating 130 outside the listed specifications,contact your local distributor for Starter motor rated voltage(DC) 12 further analysis and advice. Battery,recommended cold cranking Lubrication amps(CCA): Qty.,rating for-18°C(0°F) One,630 Lubricating System Battery voltage(DC) 12 Type Full Pressure Battery group size 24 Oil pan capacity,L(qt.) 5.7(6.0) Oil pan capacity with filter,L(qt.) 7.1 (7.5) Oil filter:quantity,type 1,Cartridge G4-306 (48RCLC) 4/26e Application Data Cooling RDC2 Controller Radiator System 60 Hz Ambient temperature,°C(T) 45(113) Radiator system capacity,including engine,L(gal.) 21.3(5.6) Vdtape: 240 V Engine jacket water flow,Lpm(gpm) 131 (34.6) Fdtq: 60.0 Hk Heat rejected to cooling water at rated o kW,dry exhaust,kW(Btu/min.) 48(2730) Water pump type Centrifugaly Fan diameter,mm(in.) qty.3 @ 356(14) Fan power requirements(powered by engine battery charging alternator) 12VDC,18 amps each The RDC2 controller provides integrated control for Operation Requirements* the generator set, Model RXT transfer switch, programmable interface module(PIM),and load shed kit. Air Requirements 60 Hz Radiator-cooled cooling air, The RDC2 controller's 2-line LCD screen displays status m3/min.(scfm)t 62.2(2200) messages and system settings that are clear and easy to Air over engine,m3/min.(cfm) 31.1 (1100) read,even,in direct sunlight or low light. Combustion air,m3/min.(cfm) 5.5(195) t Air density=1.20 kg/m3(0.075 Ibm/ft3) RDC2 Controller Features • Membrane keypad: Fuel Consumption* o OFF,AUTO,and RUN pushbuttons Natural Gas,m3/hr.(cfh)at%load 60 Hz o Select and arrow buttons for access to system 100% 24.8(875) configuration and adjustment menus 75% 20.3(717) . LED indicators for OFF,AUTO,and RUN modes 50% 14.5(512) . LED indicators for utility power and generator set source 25% 8.7(307) availability and ATS position(Model RXT transfer switch 60 Hz required) LP Gas,at%load m3/hr.(cfh) Gal/hr. . LCD screen: 100% 8.9(315) 8.7 o Two lines x 16 characters per line 75% 6.3(222) 6.1 o Backlit display with adjustable contrast for excellent 50% 4.7(165) 4.5 visibility in all lighting conditions 25% 3.0(106) 2.9 Scrolling system status display t Nominal Fuel Rating: Natural gas,37 MJ/m (1000 Btu/ft3) • LP Vapor,93 MJ/m3(2500 Btu/ft3) o Generator set status LP vapor conversion factors: o Voltage and frequency 8.58 ft 3=1 lb. o Engine temperature 0.535 m3=1 kg. o Oil pressure 36.39 ft 3=1 gal. o Battery voltage * 50 Hz Operation Requirements are available upon request. o Engine runtime hours Sound Enclosure Features Date and time displays • Smart engine cooldown senses engine temperature • Sound-attenuating enclosure uses acoustic insulation Digital isochronous governor to maintain steady-state that meets UL 94 HF1 flammability classification and speed at all loads repels moisture absorption.• Internally mounted critical silencer. Digital voltage regulation:t1.0% RMS no-load to full-load •Skid-mounted,aluminum construction with two Automatic start with programmed cranking cycle . Programmable exerciser can be set to start automatically removable access panels. g y • Scratch-and corrosion-resistant cashmere powder- on any future day and time,and to run every week or baked finish. every two weeks • Exercise modes Sound Data o Unloaded exercise with complete system diagnostics Model 48RCLC sound levels are 61 dB(A)during engine o Unloaded full-speed exercise exercise and 61 dB(A)during normal operation.* o Loaded full-speed exercise(Model RXT ATS required) • Front-access mini USB connector for SiteTech All sound levels are measured at a distance of 23 ft. (7 m) connection from the generator set. • Integral Ethernet connector for KOHLER Energy * Lowest of 8 points measured around the generator.Sound levels Management at other points around generator may vary depending on • Built-in 2.5 amp battery charger installation parameters. • Remote two-wire start/stop capability for optional connection of a Model RDT transfer switch See additional controller features on the next page. G4-306 (48RCLC) 4/26e Discovery Energy,LLC KOHLER. Generators For Twin Oaks Road,Kohler, 53044 USA For the nearest sales and service outlet in the US and Canada,phone 1-800-544-2444 kohlergenerators.com Additional RDC2 Controller Features Available Options(continued) • Diagnostic messages Enclosure Option o Displays diagnostic messages for the engine, ❑ 291 kph(181 mph)Wind Load Rated Enclosure generator, Model RXT transfer switch, programmable Starting Aids§ interface module(PIM), and load shed kit , ❑ Block Heater, 1500 W, 120 V* o Over 70 diagnostic messages can be displayed• Maintenance reminders ❑ Block Heater, 1500 W,240 V • System settings * Single phase QS available with factory installed block heater o System voltage,frequency, and phase §Recommended for ambient temperatures below 0°C(32°F) o Voltage adjustment Controller Accessories o Measurement system, English or metric ❑ Lockable Enclosure or Remote Mount Emergency Stop • ATS status(Model RXT ATS required) o Source availability (lockout/tagout) o ATS position(normal/utility or emergency/generator) ❑ Programmable Interface Module(PIM) o Source voltage and frequency (provides 2 digital inputs and 6 relay outputs) • ATS control(Model RXT ATS required) Automatic Transfer Switches and Accessories o Source voltage and frequency settings ❑ Model RXT Automatic Transfer Switch with Combined o Engine start time delay Interface/Load Management Board o Transfer time delays ❑ Model RDT Automatic Transfer Switch o Fixed pickup and dropout settings ❑ Load Shed Kit for RDT or RXT o Voltage calibration • Programmable Interface Module(PIM)status displays ❑ Power Relay Modules(use up to 4 relay modules for o Input status(active/inactive) each load management device) o Output status(active/inactive) ❑ Other ATS • Load control menus Miscellaneous o Load status ❑ Maintenance Kit(includes air filter,oil,oil filter,and o Test function spark plugs) Generator Set Standard Features Literature • Aluminum sound enclosure with enclosed silencer ❑ General Maintenance Literature Kit • Battery rack and cables ❑ Overhaul Literature Kit • Coolant in generator ❑ Production Literature Kit • cUL/UL 2200 listed,CSA certified Warranty • Electronic, isochronous governor ❑ Extended 7-Year/2000 Hour Premium Limited Warranty • Engine-generator set is designed and manufactured in ❑ Extended 10-Year/2000 Hour Premium Limited Warranty facilities certified to ISO:9001. • Flexible fuel line Dimensions and Weights • Gas fuel system(includes fuel mixer, electronic Overall Size,L x W x H,mm(in.): 2280 x 836 x 1182 secondary gas regulator,two gas solenoid valves,and (89.8 x 32.9 x 46.5) flexible fuel line between the engine and the Shipping Weight,wet,kg(lb.): 767(1690) skid-mounted fuel system components) Weight includes generator set with engine fluids and 4Q713X • GFCI service outlet(120/240 V)for customer alternator,sound enclosure,and silencer. connections . Integral vibration isolation • Line circuit breaker • NEC prime mover shutdown switch " • Oil drain extension • KOHLER Energy Management for remote monitoring • Operation and installation literature �4—w­01 1. L .� • RDC2 controller with built-in battery charger NOTE:This drawing Is provided for reference only and should not be used for • Standard 5-year/2000-hour premium warranty planning Installation.Contact your local dealer for more detailed Information. Available Options DISTRIBUTED BY: Electrical System ❑ Battery ❑ Battery Heater ❑ Wireless Radio Kit Fuel System ❑ Dual Fuel Automatic Changeover Kit with Reset Box ©2026 Discovery Energy,LLC-All rights reserved. G4-306 (48RCLC) 4/26e 1 4 Rll:r W M GRAVEL do FEW COBBLES(SW) SILTY SANG(SM ---{T} ____ s�F{}___-0RUYo xooRu 4 ].T wmw C.W.I.Mawr Id.CT 06268 ANTICIPATED GROUND WATER ELEVATION- OW ELEVATION 44 / / _ ----n6_uan _-. ��' --- ,61 Eaalflbe.,CTO6 Fmm SO CLA�('�T1aNs / �___ ['¢ O µ^NY ° __ ea6.eesm551 .mammvanlo..mm / / I � Eael NanleM,CT 661a6 PIB-PW..th Laamy Cmaraer SarM 3 to BS alO rr CLEAN 1/A SEPTIC-e]mmal 0®a i0R ID�OROOIIS / / / CarvraLA vuu PROVIDE 2 LF.4'C.I.PIPE BETWEEN HOUSE/COTTAGE AND CLEAN-OUL uAW POND LOCATE GEAR-OUT 2'FROM FOUNDATION WALLS. Ao,LaTAniR Tnc Y• c sr aY nMr[wo COLS PROVIDE MANHOLE PRIOR TO FUJ TANK TO COMBINE FLOWS FROM HOUSE&COTTAGE (ro a-rut TOR N•-INov). PROVIDE mJ CLEAN WASTEWATER TREATMENT SYSTEM-YCDEL CEN 14 / Q YARINOT TO-A71C (1,350 G'PD CAPACITY-MAXIMUM 12 BEDROOMS) 'bT 9CAE MEET PROVIDE 1 DISTRIBUTION BOX J / zs • PROVIDE 10 CONCRETE LEACHING GALLEYS SEE DETAIL \ / �_ / // tiWIAaND � S�x LEACHING REWWm-700 SO.FT.-PROVIDED-795 SO.FT. I t WASTEWATER TREATMENT SYSTEM SHALL VENT THROUGH THE SEWER PIPE A HOUSE / .� / i / TRAP SHALL NOT BE INSTALLED UPSTREAM OF UNIT. NO ADDITIONAL VENTING IS \\\/// !// / REQUIRED ) EXISTING SEPTIC SYSTEM TO BE LOCATED,PUMPED AND REMOVED OR FILLED WITH SAND.PROVIDE FORM W1M1-080 yAC Cr \ ; I voLvwHavltFx��1R. III 6WP]AI¢m R morausWlt sou INVERT FMg AT�s_- O� ,V�. ,."' PROVIDE��� srta ws•IY o.a aR ttaAlAxr To SITE DEVELOPMENT PLAN OUTLET AT HOUSE-5Y"25 ,q (� --- I \I WASHOUT PIT ygFl�TO OUTLET AT COTTAGE-54.00 V (SE DETAIL) AT 1FA9t TIHRA-•WIDE -1-INITTIL RIA11110t FOR PREPARED FOR: MANHOLE INLET-51.70 I-?+ / 0 \ ,� O tIC DIAIHEIu?M FWz NAST JONIT ALANX fR CHRIS di BONAVENTURA MANHOLE OUTLET-51.60 F \\ TANK INLET-51.50 E� i - _ _ & ELLEN di BONVENTURA TANK OUTLET-51.33 \\ \ D-BOX INLET-51.00 S�R '- cAWr•wA¢i1DOME 330 ETTRICK STREET D-Box ouTLEr-sO.92 �( i r YnµaTt� v� o FISHERS ISLAND LEACHING GALLERIES BOTTOM-48.25 �G / NEW YORK DRA CHI AEONS - -:1'u 17-]C mlOIQ11_f_ 4C la a fllaE I11IH3J1 soar. \// �R /;-- O ' l.a� ~� LOCATION MAP SCALE 1"=400' OUSTING ROOF AREA .3.150 SF / �•7. i - `'. - _- ,'�'•' TYPICAL MANHOLE DETAIL PROPOSED ROOF AREA 3,9D0 SIF - O' • , NEW ROOF AREA -750 SF - . Nor ro swE REQUIREDJ,900 SF X 2 IN/12 IN/FT=650 CF I.All N MOUDS sRmo swHl cww To_TAD�TC uscsT HG\BOY L n�P / ` \ ERAZE&DISPOSE OF XISTING RESIDENCE i / m RwmpmF®M s °PQ''X Mx aLlnr6 `� .],A OI P IEIWIR A]I�AEY 650 WELLSDRY 50.28 Ci 12"9 VF REWIRED � _ �� _ o (TYP) iml romi[�aminT. 0ma r9 AmT mnv°'a. / /VF / - _ j f I.)SURVEY YAP PREPARED FOR JOSEPH YATBIN GORE F16mPoCH5 h USE FOUR(4)WO X 4'DEEP DRY WELLS. '�- -I" f' ' \ APPROXIMATE 111DT5 77 LORRAINE CAFFERY FMEDWCHS ETTRICK STREET FISHERS ISLAND.NEW YORK `\` OF DISTURBANCE PREPARED BY CHANDLER,PALMER&KING DATE:JUNE 16.1999 SCALE: PROVIDE SIDEWALU(, A ^> _ \ ti7.930 SF I'.40'94EET 1 OF 1. STRAW BATE WIRB.E ARCITECTURALAPLANS I 2.)SURVEY YAP PREPARED FOR CHPoSTOPHER DI BONAVENTDPA&E11FJ/01 PLASnC UNWC " -) i�_,./ rr1 ,!��!,r, '\'^\ BY ONEENGINEERING,STREET.FISHERS &ARCHITECTURE RPREPARm NATIVE MATERIAL r ___ - BATED:02/24/2012.SCALE:1'-20',SHEET 1 Of I.- (ovnOMAL) \ Tf /A 'J/ \ \\ PROVIDE NEW WATER SERVICE To Cottage OF NE SECTIOM B-e ROOF COORDINATE WITIR FlSIERS INLAND OUSTER COMPANY \ 1� \� �' 10 \ FROM MAW RESIDENCE m w,s..re.•,.,n Ma.o.e.a MN,o � ly moo OR NOT'TO�CSE TO INSTALL NEW WATER SERVICE OR VERPV• /�T"- /, �r \ ♦" EXISTING COTTAGE )' METAL STAKES CONDITION&CAPACITY OF EDSIWC SERVICE 1 d� y�P 4KSP M.P4gFp9P (2 PER BATE) (MAINTAIN/0'MIH,SEPARATION TO DRYWELS& "�, ,i` unlssl aa-sTsa.a hwnla • . SANITARY SEWER COIPAENTS ^\ 2 POSE ,�` \ \1 EXISTING 1 BEDROOM •dr•rc•.,•ad.dJ•wP.nwn(•1 1.)THIS SURVEY WAS PREPARED FOR THE PARTIES AND PURPOSE INDICATED . ) _ \ -, \ \ COTTAGE TO REMAIN m aw HEREON.ANY EXTENSION OF THE USE BEYOND THE PURPOSED AGREED TO q -. 10'MIN. \\ // FFIO"00 \ A\� ._•1 „ mlRESIDENCEP 'tx w6w¢L�� ENGAGEMENT.BETWEEN THE CUFlRT AND THE SURVEYOR IXC®9 ME SCOPE OF THE -Tw+ Or TB orv¢�E COED 2.)IT IS A VIOLATION OF THE STATE EDUCATION LAW FOR ANY PERSON. Olo8963V 62 SINGLE FAMILY RESIDENCE TI°FaP°C UNLESS ACTING UNDER THE DIRECTION OF A LICENSED LAND SURVEYOR,TO gOPE9610NP /. (PUBLIC WATER) ALTER AN ITEM IN ANY WAY. VARIES YFP°' '�/"•� '%,' PROMOE SYSTEMA CONTRAS&ALARM MOUNTED 7D BUILDING EXTERIOR o m ]J ONLY CWIES OF THIS SURVEY MARKED WITH THE LAND SURVEYORS Aeonm SVS lv�rnmluta aer V$S \ / J,•/' PROVIDE WEATHER PROOF ENAONDES o fl o m SIM TURF AND AN ORIGINAL EMBOSSED OR INK SEAL ARE THE PRODUCT OF AS REDUBRED(TP) saPE ASYREoflEa O m THE LAND SURVEtt1H. Rewavo �m=��w� (ALL COHPONFT115 70 BE HARD WINED) ® I.-OR R ` o m o 4.)COORDINATE DISTANCES ARE MEASURED FROM U.S.COAST AND GEODETIC PROVIDE FUJMAC 20O®BLOWER N VENTED wt SURVEY TRIANGULATION STATION'PROS' ' PROVIDE a SCAR 33 pY-; •` w o PLASTIC STRAW BALE ROOF GRAIN WTIET \U 1 - /. ENCLOSURE ON CONCRETE PAD e UNWG pyy LTYP) O 0.OU LET \ �D" INSTALL PER MANUFACTURER'S RECOMMENDATIONS 5.)9TE IS W THE TOMOF SOUTHO D.COUNTY OF SUFFOLK I"YAP STORMWATFR DR NEI I DETAILxOT TO SCALE - //i � 1000,SECTION 009,BLOC(it LOT 9. L / \ rs° ratlER WASenn PT •�+�:it.�(:.;I !FJ r TS SEtOP°K •s r a 6.)TOTAL AREA.O.SBt SORES. NOTES 'VAYWY COIF COURSE \ - �/ •.`�,i4 . 1. S NS SHOWN ARE FOR TYPICAL RESIDENTIAL (PUBLIC WATER) ( - 7.)SITE IS LOCATED W R-80 ZONE.OIY CONSIRUCTON.LARGER PROJECTS ON PROJECTS REOUIRWG PUNPS MAST BE SIZED ACCCROINGLY(7 GALLONS/TRUCK SOGALLGNS/PUMP.PINS MIN.v mmoARU). PROVIDE - ? WOVEN IRE FENCE(NUN.14 2 CAR RE MATERIAL AND UOUIDS MUST BE REMOVED FROM 8•/X 4'DRY WILL \ _ _ PROVIDE W SCH 40 PVC AIR LINE TO BLOWER GAUGE W/MAX.6'MESH I AM FAMILIAR WITH THE STANDARDS FOR APPROVAL PIT AND PROPERLY WSPOSED OF WHEN THE PIT REACHES FOR ROOF RUNAP S4 \ 4 INSTALL PER MANUFACTURER'S RECALMERDAIIOrRS SPACING) AND CONSTRUCTION OF SUBSURFACE SEWAGE 75%OF ITS CAPAOtt. (T'P,SEE DETAIL) -/ 10• DISPOSAL SYSTEMS FOR SINGLE FAMILY RESIDENCE ]. INSPECT PIT macro ro EACH ug ro ENSURE ccNrawaENT �� _ • \ PROVIDE 2 ROWS OF s MAX CENTER 7o DEN 36'MIN.LENGTH AND WILL ABIDE BY THE CONDITIONS SET FORTH OF WASH WAmt t o D D • CONCRETE LEACHING TER FENCE POSTS THEREIN AND ON THE PERMIT TO CONSTRUCT. PROVIDE MANHOLE(SEE DETAIL) ; -- - 33 GALLERIES(SE DETAIL) DRIVEN MIN.16' TS .1 or - -' \\ Q INTO GROUND APPLICANT w 3 PROVIDE F CEN-14 WASTEYA7Et ••.a. C_-1 r-1 n GRADE i TREATMENT SYSTEM(SEE DETAIL) �', h L_.l L•.•-J L_1.Cr_J.L_J FXWiNG °/ / \� ^ \ 504 EXPANSION AREA I! tsnPIFIE LW'Al DYP) u >a-]] OWO TO REMAIN "_\' __ _52 - -,. _.. /) (Tp) I I HDGHT • 51 \ f OF FILTER F--.- �ti� 16'MIN. ----_--- - PROVIDE IOTT cgjUt,Y D-EnDc (- ®D \ - BOX(SEE D�E7Aa) ®DM�3 ®CE�3 - f O/ 6"MIN. PROVIDE SILT FF]IfE-''I 4J. I �®® ®®lam I O `MAINTAIN DURING _ CONSTRUCTION PERSPECTIVE VIEW ®®®®E ® APPRW WEATE LOCATION OF EXISTING SUrFOLH COUNTY DEPARTnnCM OF HEALTH SERJiC[5 I SEPTIC SYSTEM-ABANDAU PER \ / PERMIT FOR APPROVAL OF CONSTFG non FORA S�mWaIRRernWn �, Caw ®®®T®® I SCONS REQUIREMENTS PROVIDE FORT/ WOVEN IRE FENCE(MIN.14 pl SINGE Funrtr REs-NCE AND EIr--- IS Yz WAU-080 1/2 GAUGE W/MAY 6-MESH WngaCW9a �I .I"':. i SPACING)NTH FILTER CLOTH ? 1 SWiLS CIXAMENf9 PAR emirtrE 1 I AbawovmnT of oxc gamry sy mmmst Eeln I 36'MIN.FENCE POST DATE 1111-a H.S.REF R-V'Mo L(XIAA3 SAIo-CIMWL(sW) 3 _. u_--ll_y---Jl ewVomlarea wiN Uie Depamnom's ragwemams. _ UNDISRIRBEO IN APPROVED- C--,y 2 SCDN3OC,A ENTS PAP 1L92ROl! CONCRETET S.-mmgwm lone l 4180az ProofFLOWS �1,;ROLIND TOTA>�MMA#M1n1 LSFDROpeS 'J 11 � 4•-LEACHING8 8>t3, �uLgepWATv t, \ • V \;�\;\• EXPIRES THREE YEARS FROM DATE OF APPROVAL NOT ro SCALE COMPACTED SOIL EMBED FILTER CLOTH LEGEND�\\\!\\'! o I I \ 20 10 0 20 A YIN.OF 6'IN GROUND � -\' GRAPHIC SLATE IN FEET y PROPERTY LANE IF YAIOIUE IC YWgL LIMP Z4'YAI4HML CW1W1(OPig1W3 -� ..• ABUTTERS LANE -- I r LOCKING COVER TO LRAOE ULOONG COVER TO GRADE EDGE OF PAVEMENT TF-55.0 7F tSA 2 SECTION VIEW EDGE OF GRAVEL ___________________ Ile 1 AEON OUT LOCKING COVER TO GRADE EXISTING CONTOUR ---XXX--- �� 60 EXISTING GLADE TF_tF>z9 CONSTRUCTION SPECIFICATIONS STONE WALL 11 LOCARG COTh7R 7D GRADE BURIED CONCRETE COMER(TYP) 60 RETAINING WALL 1 58 _____. .-. _ _7F'-t318 - -1'OM ._ - 58 1.WOVEN WIRE FENCE TO BE FASTENED SECURELY TO FENCE POSTS WITH UNITS OF INLAND WETLANDS Ate/ • °' 1�' S6 --- --- -- _ PROPOSED GRADE 56 %R TIESHARD OR STAPLES,POSTS SHALL BE STEEL ETHER-r OR'U'TYPE - FENCE -�3E-=T- -- - --- ---...-- - TREE uNE v Vw w SITE PLAN 0!1- 52 -.__-___-__ __-___--- - -__ ---_ 52 Z.FILTER CLOTH TO BE FASTENED SECURELY TO WOVEN PARE FENCE WITH OVERHFAD WIRES W. Y-I 1 INV-S2T3 TIES SPACED EVERY 24'AT TOP AND MID SECTION.FENCE SHALL BE NOW OR FORMERLY NIF $O -r 50 NOVEPN MARE,6'MAXIMUM MESH OPENING. UTILITY POLE t NV..31.70 48 ___ _-_NV.�1S0_ _ __ _ l-. 1_ __ _ 48 BOUNDARY POINT • 1/F • • YAIDIAE INV..5133 �EXPAH90N ATtFA 3.WHEN TWO SECTIONS OF FILTER 0.0TH ADJOIN EACH O1XER THEY CLOTH DRILL HOME • s 9ne wn narked • • 48 WK.51.60 -___. 46 SHALL BE OVER-CAPPER BY ITT INCHES AND FBILNK T140N, R APPROVED 44 - -•- - - •' FXPECfFvP.. A '( MD 44 SHALL V BE ETHER FILTER X. SIX I HES SD FOLDS.FILTE OR APPROVED IRON MONUMENT GH• OevAM d BY Drop Y C PMP BY 42-_ _ - _ __.__ __ -_ __-_.�•h50.8_ __.. -4.2 LEFT DEPARTMENT MONUMEENT(CHO)CONNECTICUT HIGHWAY • FW AFiIN CEJ-14 LEACHING GALLEYS WN.ST•00 N1L.50•W2 4.PREFABRICATED UNITS SHALL BE GEOFAB. CE Is a Date: Project No: Scale' 3' d' 40 B1Y EEV.�4S2S 40 EQUIVALENT. IRON PIPE IP 07l082022 076915 1•.20' L IRON ROD ITT S.MAINTENANCE SHALL BE PERFORMED A9 NEEDED AND MATERIAL RAIL ROAD SPIKE Pot5P1( Drawing No.: 1 . FILE REMOVED WHEN'BULGES'DEVELOP IN THE SILT FE WE FUJ a FAN CFN-14 SYSTEM PRO WATER LLL VALVE x ToscuX SCALE 11.10' SILT FENCE SHEET 1