Loading...
HomeMy WebLinkAbout44653-Z aoF souryOlO Town of Southold P.O. Box 1179 oQ 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 47037 Date: 05/08/2026 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1205 Tuthill Rd Ext Southold, NY 11971 Sec/Block/Lot: 55.-6-15.52 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 01/24/2020 Pursuant to which Building Permit No. 44653 and dated: 02/03/2020 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof-mounted solar panels on existing accessory garage as applied for. The certificate is issued to: Gabriel Glantzman , Debra Stroup Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 44653 5/5/2026- PLUMBERS CERTIFICATION: tho ' Si ature TOWN OF SOUTHOLD A''�guFFQI,��,O BUILDING DEPARTMENT y z TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 44653 Date: 2/3/2020 Permission is hereby granted to: Glantzman, Gabriel & Stroup, Debra 225 4th Ave Greenport, NY 11944 To: install roof-mounted solar panels on existing accessor y garage as applied for. At premises located at: 1205 Tuthill Rd Ext, Southold SCTM # 473889 Sec/Block/Lot# 55.-6-15.52 Pursuant to application dated 1/24/2020 and approved by the Building Inspector. To expire on 8/4/2021. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO -ACCESSORY BUILDING $50.00 Total: $200.00 i ilding Inspector �aoFgQ�,y° TOWN OF SOUTHOLD BUILDING DEPARTMENT ' SOUTHOLD, NY BUILDING PERMIT RENEWED (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 44653 Date: 02/03/2020 Permission is hereby granted to: Renewal Date: 05/05/2026 Gabriel S Glantzman 1205 Tuthill Rd Ext Southold, NY 11971 To: install roof-mounted solar panels on existing accessory garage as applied for. Premises Located at: 1205 Tuthill Rd Ext, Southold, NY 11971 SCTM#55.-6-15.52 Pursuant to application dated 01/24/2020 and approved by the Building Inspector. To expire on 05/05/2028. Contractors: Fees: Renewal Fee all $100.00 otal 100 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. January 23, 2020 New Construction: Old or Pre-existing Building: x (check one) Location of Property: 1205 Tuthill Road Extension Southold House'No. Street Hamlet Owner or Owners of Property:' Debra Stroup/Gabriel Glantzman Suffolk County Tax Map No 1000, Section Block Lot Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: GreenLogic LLC Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: x (check one) Fee Submitted: $ 50 A V licant Signature hO��pF SOUjyo�o Town Hall Annex Telephone(631)765-1802 54375 Main Road G Q P.O.Box 1179 ; Southold,New York 11971-0959 ��iY�DUNTI,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Gabriel Glantzman Address: 1205 Tuthill Rd Ext City: Southold St: NY zip: 11971 Building Permit#: 44653 Section: 55 Block: 6. Lot: 15.52 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Electrician: GreenLogic License No: 43858ME SITE DETAILS Office Use Only Commercial Indoor X Basement Service Solar X Residential X Outdoor X 1st Floor Pool Battery Storage As-built Renovation 2nd Floor Hot Tub EV Charger New X Addition Attic Spa Generator Survey ix I Mezzanine Garage ix I Dock INVENTORY 'Service 1 ph In-wall Heater Recpt Ceiling Fixtures Smoke Detectors Pump Service 3 ph Hot Water GFCI Recpt Wall Fixtures CO Detectors Heater Main Panel A/C Condenser Single Recpt RecessdFixtures Combo Smoke/CO Transformer Sub Panel A/C Blower Range Recpt Ceiling Fan Heat Detectors Salt Gen Transfer Switch Mini Split Dryer Recpt UC Lights Fridge AutoCover ARC Blower Heads Switches Pucks Lights Dishwasher Mini Fridge GFI SepticDisconnect Emrgency Strobe 4'LED Microwave Garbage Disp. ARC/GFI ERV Exit Lights Bath Exhaust Hood Dehumidifier Other Equipment: 9.81kW Roof Mounted PV Solar Energy System w/(30)SPR-E20-327E-AC Modules, 50A Fused Disconnect, 50A Non Fused Disc, 12 Circuit Combiner Panel in Garage Notes: On Backfed 50A In Main Panel Solar On Acc Garage Feeding to House Inspector Signature: Date: May 5, 2026 pFSOI/lyo�o Li # TOWN OF SOUTHOLD BUILDING DEPT. �ourm ' 765-1802 - � -INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION`21SID JANSULATIOWCAULKING [ ] FRAMING/STRAPPING [ ] FINAL { ] FIREPLACE &CHIMNEY" [ ]-,,FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: DATE 11A 2A INSPECTOR OE SOUI - - ---- ----- -- - ---- ,'Y. # TOWNe OF SOUTHOLD BUILDING DEPT. co ran�F'' 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] -ROUGH PLBG. [ ] FOUNDATION 2ND [ } ULATION/CAULKING [ ] FRAMING/STRAPPING [ FINAL SojMF✓ [ ] FIREPLACE'&--CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] ,-FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: l DATE 1 'L INSPECTOR �o�apF SO(/lyOlo L4}H l V # # TOWN OF OUTHOLD BUILDING DEriT'. " Coulo, 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) }, ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ]' PRE C/O [ ] RENTAL REMARKS: 0A DATE INSPECTOR PAP Pacifico Engineering PC __ Engineering Consulting 700 Lakeland Ave, Suite 2B C Ph:631-988-0000 -- r Bohemia, NY 11716 I G c solar@pacificoengineering.com March 23,2020 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Debra Stroup 1205 Tuthill Road Extension Southold, NY 11971 have reviewed the solar energy system installation at the subject address on March 23,2020.The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets the requirements of the 2015 International Residential Code-2nd Printing modified by the NYS Building Standards and Codes 2017 Uniform Code Supplement, and ASCE7-10. To my best belief and knowledge,the work in this document is accurate, conforms with the governing codes applicable at the time of submission,.conforms with reasonable standards of practice,with the view to the safeguarding of life, health, property and public welfare. Regards, Ralph Pacifico, PE Professional Engineer OF Ai M I � R sia�KE r(eer NY 666182 W4. Ofi/FL 87297 FIELD INSPECTION REPORT DATE COMMENTS � b FOUNDATION (1ST) �IL I V'' -------------------------------- FOUNDATION (2ND). ul a 1 ROUGH FRAMING& r PLUMBING y 1 INSULATION PER N.Y. C y STATE ENERGY CODE t 2� FINAL ADDITIONAL COMMENTS m • z C TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets.of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey Southoldtownny.gov PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application 1� A Flood Permit Examined ,20 Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: Approved 20; Mail to: Green Logic LLC Disapproved a/c 97 North Sea Road, Southampton, NY Phone: 631-771-5152 Expiration ,2 Building Inspector APPLICATION FOR BUILDING PERMIT JAN 2 4 2020 Date January 23 , 20 20 INSTRUCTIONS a. This applicatioho WST.be`completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale. Fee according to schedule. ; b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building'shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing, the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. GreenLogic LLC (Signature of applicanyor name,if a corporation) 97 North Sea Road,Southampton, NY 11968 (Mailing address of applicant) J State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Contractor Name of owner of premises Debra Stroup/Gabriel Glantzman (As on the tax roll or latest deed) If applicant is a corporation;signature of duly authorized officer Nesim Albukrek, President (Name and title of corporate officer) Builders License No. 40227-H Plumbers License No. N/A Electricians License No. 43858-ME Other Trade's License No'. N/A 1. Location of land on which proposed work will be done.: 1205 Tuthill Road Extension Southold House Number Street Hamlet County Tax Map No. 1000 Section 55 Block 6 Lot 15.052 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Single family dwelling b. Intended use and occupancy Single family dwelling 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work Roof mounted solar electric system on garage (Description) 4. Estimated Cost $35,749 FEe $200 (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height .Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase 5/10/19 Name of Former Owner Sandra Et Joseph Kollen 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO X 13. Will lot be re-graded?YES NO X Will excess fill be removed from premises?YES NO X 14. Names of Owner of premises Debra Stroup 125 Tuthill Road Ext. 631-407-5371 Address c,,,fthold, NY 11971 . Phone No. . Name of Architect James J. Stout Address_2 Greg Ln, E. Northport Phone No 631-858-9388 Name of Contractor GreenLogic LLC Address97 North Sea Road Phone No. 631-771-5152 Southampton, NY 11968 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO X * IF YES, SOUTHOLD TOWN TRUSTEES.&D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO X * IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO X * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF Suffolk . Nesim Albukrek being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named,. (S)He is the Contractor (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me t 's day o 20 Not Public RBARA A CA n' Notary Public-State of New York ignature of Applicant No. 01-CA4894969 Qualified in Suffolk County Commission.Expires May 11, 2023 Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) 1, D,-6mre��/Cva6,,qJ Ckty i"Kesiding at 120'S -G--k<lI yz" fa ACC. (Print property owner's name) (Mailing Address) -Ehc►`cp do hereby authorize GreenLogic LLC (Agent) to apply on my behalf to the Southold Building Department. amc4r4 9 , 2 62-6 (Owner's Signature) U (D e) (Print Owner's Name) Q0.' STATE k%5>' OF NEW YORK` NOTARY PU9LIC �Qi0 M 8ulbq CaxKy • ®t6UM31384 V. s 'ly • - ��►uu mUPp CONSENT TO INSPECTION De—bra- o u a6-fv-( kj4zwft, the undersigned, do(es)hereby state: Own s)Name(s) That the undersigned(is) (are)the owner(s) of the premises in the Town of Southold, located at 1 Zo5 "C"A'km ►2ocj Sow-4-Hold, nl y , which is shown and designated on the Suffolk County Tax Map as District 1000, Section 5 5 ,Block�,Lot 15.0 5'2 . That the undersigned(has) (have) filed, or cause to be filed, an application in the Southold Town Building Inspector's Office for the following: Roof mounted solar electric system That the undersigned do(es)hereby give consent to the Building Inspectors of the Town of Southold to enter upon the above described property, including any and all buildings located thereon,to conduct such inspections as they may deem necessary with respect to the aforesaid application, including inspections to determine that said premises comply with all of the laws, ordinances,rules and regulations of the Town of Southold. The undersigned, in consenting to such inspections, do(es) so with the knowledge and understanding that any information obtained in the conduct of such inspections may be used in subsequent prosecutions for violations of the laws, ordinances,rules or regulations of the Town of Southold. Dated: tt (Signature) d IpfO- OLJ..� � Name ct� (Signature) ,`,,,,NII\111111 tt II t tttl,, t�.G�qq, .,, �N YORK � ' (Print Name) s -�iouR`' m�LIC� �yy,�ofo U633 sae ' I Imo' IA A � 9zo� o BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD .. Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX(631) 765-9502 roger.,riche town.southold Hy,.us APPLICATION FOR.ELECTRICAL INSPECTION. REQUESTED BY: Barbara Casciotta Dater 1/23/2020 Company Name: GreenLogic LLC Name: Robert Skypala License No.: 438587ME email: AM@Greenlogic.com Address: 97 North Sea Road, Southampton, NY 11968 Phone No : 631-771-5152 ... ... . ..._.... . JOB SITE INFORMATION: (All Information Required) Name: Debra Stroup Address: 1205 Tuthill Road Extension,_Southold Cross Street: Phone No.: 631-407-5371 or 631-332-0055 , r�� email: deb_strou @hotmail.om BIdg.Permit#: �-r�t"��3 P Tax Map District: 1000 Section: 55 Block: . 6 Lot* 15.052 BRIEF DESCRIPTION OF WORK(Please Print Clearly) Roof mounted solar electric system on garage (30) SunPower SPR-E207327-E-AC panels with micro inverters 9.810kW - Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: FY—ESJ NO Issued On Temp Information: (All information.required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect-Service Reconnected -Underground - Overhead #-Underground_Laterals 1 2 H Frame Pole Work done on Service? Y N... Additional Information: PAYMENT;DUE WITH APPLICATION 82-Request for Inspection Form.xis Scott A. Russell T01KMWA—.T]E]K SUPERVISOR ( r \j I��[Al�A\G]E1��1t1E1�T SOUTHOLD TOWN`HALL-P.O.Box '1179 �J ,, 53095 Main Road-SOUTHOLD,NEW YORIC 11971 Town of Southold CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) ............ ............ ....... .. ........_... .. . . .... ...... . . .... .._ .................................. s , DOES THIS PROJFC'T INVOLVE ANY of THE FOLLOAVING. (CHECK ALL THAT APPLY? } Yes No ❑Q A. Clearing, grubbing; grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑ x❑ B. :Excavation or filling involving more than 200 cubic yards of material I within any parcel or any contiguous area, ❑❑ C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑❑ D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑El E. Site preparation within the one-hundred-year f loodp lain as depicted on FIRM Map of any watercourse, i ❑❑ F. Installation of new or resurfaced impervious surfaces of 1,000 square feet. or more, unless prior approval of a Stormwater Management Col-itrol Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. } If you answered NO to ali.of the questions above, STOP! Complete the Applicant section below with your Name, Signature,Contact Information, Date & County Tax Map Number! Chapter 236 does not apply:to your project. If you answered YES to one or more of the above,please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. —_- � . Date: APPLICANT: (Property Owner,De.mgn Professional,Agent,Contractor,Other) j( S.C'.rv�.M. i 000 NANIE; _GreenLogm LLQ(N im Alb tkr .kl l 55 6 15.052 1/23/2020 M; T " Section B1061. Lot ..................................................... ... " — 1. FOR BUILD1NG.D�LPAKi MEN[ USE ONLY" Contact Information X'1"-"7"71-5152 ? j Pt'ciptw�m P:om�xr3 � �f Reviewed By: ? — —Date: Properly.Address J Location of Construction Work: � — — — — — — — — — — — — — ; ! Approved for processing Building Permit. ; 1205 Tuthill Road Extension , Stornnvatei Management Control Plan Not Required. Southold, NY 11971 I — - - - — — — — — — — — — — — — — Stormwater Management Control Plan is Required. ......... �' (Forward to Engineering Department for Review.) ......................._............__...................................................................................................................._......_............................................................ ... ... ............................................._.._ ? FORM # SMCP-TOS MAY 2014 r LOGIC® ENERGY January 23, 2020 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Dear Building Inspector: Please find attached a building permit application on behalf of the Debra Stroup who has engaged us to install a roof mounted solar photovoltaic(PV) electric system located at 1205 Tuthill Road Extension, Southold, NY. In connection with this application, please find attached: • Building Permit application • Owner Authorization • Consent to Inspection • A Storm Water Assessment Run-off Form - • Certificate of Occupancy Application , • Application for Electrical Inspection • 2 Surveys of the Premises • 4 Engineer's Reports • 2 Three Line Electrical Drawings • 2 Spec. sheets of the solar panels • 2 Spec. sheets for Racking System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$200 ($50 Building Permit/$50 CO/$100 Electrical Inspection) Please let us know if you need anything else in connection with this application. Yours truly, 53a46ma Ca6&Wa Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 ext. 117 GREENLOGIC LLC • www.GreenLogic.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd., Suite 3 200 S. Service.Rd., #106 Southampton, NY 11968 Rosyln Heights, NY 11577 C-, 1 an+z nna t G EENLOGIC® ENERGY November 18, 2021 D /� n NOV 2 j 2021 The Town of Southold TowV,0Fso�yp�o Building Department 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Projectlnfo: Building Permit No. 44653 Debra Stroup 1205 Tuthill Rd Ext. Southold, NY To the Building Inspector: Enclosed please find the Engineer's Certification Letter for the above referenced address. Can you please close the building permit and send the Certificate of Occupancy? Please let me know if you have any questions about the installation. Sincerely, 53acv&m ea6cW& Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 Ext. 117 GREENLOGIC LLC • www.GreenLogic.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd., Suite 3 200 S. Service Rd., #106 Southampton, NY 11968 Rosyln Heights, NY 11577 GREENLOGICO ENERGY April 28, 2026 M AY 4 2026 The Town of Southold Building Department ` ':4i 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Project Info: Building Permit No. 44653 Debra Stroup 1205 Tuthill Rd Ext. Southold, NY Dear Connie: Enclosed please find our check#2723 to renew permit 44653. Best regards, 53avc6ww ea6ciettac Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 Ext. 117 _GREENLOGIC LLC • www.GreenLogic.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd.,Suite 3 200 S.Service Rd.,#104C Southampton, NY 11968 Rosyln Heights, NY 11577 N SURVEY OF PROPERTY A T SO UTHOLD TOWN T OF SO UTHOLD SUFFOLK COUNTY, KY. 1000-55-06 15.5,2 ��. SCALE- 1' 30 LOT 48 MARCH 27, 2019 REBAR SET x14sss�31 O G� p POOLx\x\ 8• i� aG 0 "' PA NELL /x\k �� + C�x CMFPOOL � LOT 49 �Ov O'ws• ?��' �� EQUIP. �• Sp PAD + 0 CURB •� IOs 2.8'N / ,p h��? ob F L=62.83- 2CURB 0 N 9� a � STONE a9�o LOT 46 �o D.10E R. FIRE a 0.8'N CERTIFIED TO. m PLACE a p! / GABRIEL GLANTZMAN AND DEBRA STROUP \�Rs OF, :k`'' P O oFoo co, 3r. FIDELITY NATIONAL TITLE INSURANCE COMPANY .00 •�, ry1ti oho �, y b VALLEY NATIONAL BANK � y6� �°' °/� ARBOR Old c \ O CONC.+ s 1 METAL S� + 5 PIPE FND. COVER y s� O- � % N, MANHOLE UTIL BOX �ry9 STOOP J. OGs��'t? CONC. F >►G 2c��• kb ,� ° 0 ti°� �`o 7T �p PAVER G� 0g �. WALK R/O WOOD LOT 47 RC KEY �� �L P,��" FEN.END Q ap FEN. 1.4N O = REBAR "NO-9O yJP '• ROW OF EVERGREENS FEN ORtiVE Y ® = WELL PSµPP�T Oy, 0.8,E D A = STAKE �2� D� BOA6t = TEST HOLE c�h ■ = PIPE OZ �sp, 'bb- REBAR SET ■ = MONUMENT = WETLAND FLAG C RLN60.00'DE-SAC S�Ps"�TFN14 r Y L=29.91' t� 2�� 7` = U71LlTY POLE ELEVA77ONS REFERENCED TO NA VD 88 LOT NUMBERS REFER TO "MAP OF HIGHPO/NT MEADOWS, SECTION THREE- FILED r ` d' .Y.S. LIC. NO. 49618 IN THE SUFFOLK COUNTY CLERK'S OFRCE ON 311,911990 AS FILE NO. 8912. AREA= 20,518 SO FT. ANY ALTERA710N OR ADDITION TO THIS SURVEY 1S A VIOLATION OF SEC710N 7209OF THE NEW YORK FAX (631) 765-1797 STATE EDUCATION LAW. EXCEPT AS PER SECTION 7209—SUBDIVISION 2. ALL CERnRCA77ONS HEREON ARE P.O. 80X 909 VALID FOR THIS MAP AND COPIES THEREOF ONLY IF SAID MAP OR COPIES BEAR THE IMPRESSED SEAL OF 1230 TRA VELER STREET THE SURVEYOR WHOSE SIGNA7URE APPEARS HEREON. SOUTNOLD, N.Y. 11971 19-016-1 Pacifico Engineering PC _ Engineering Consulting 700 Lakeland Ave, Suite 2B \ Ph:631-988-0000 Bohemia, NY 11716 IN G g solar@pacificoengineering.com January 9,2020 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Debra Stroup 1205 Tuthill Road Extension Southold,NY 11971 I have reviewed the roofing structure at the subject address.The structure can support the additional weight of the roof mounted system.The units are to be installed in accordance with the manufacturers installation instructions. I have determined that the installation will meet the requirements of the 2017 NYS Residential Code(2015 International Residential Code-2nd Printing modified by the NYS Building Standards and Codes 2017 Uniform Code Supplement),and ASCE7-10 when installed in accordance with the manufacturers instructions. Roof Section A Mean roof height 16.0 ft Pitch • 40 degrees Roof rafter 2x10 Rafter spacing 16 inch on center Reflected roof rafter span 14.7 ft Table R802.5.1(1)max allowable 20.6 ft The climactic and load information is below: CLIMACTIC AND Ground Wind Live Load, Point GEOGRAPHIC DESIGN Exposure Snow Speed,3 Pnet per pullout Fastener Type CRITERIA Category Load,Pg, sec gust, ASCE 7, load,lb psf mph psf Roof Section A C 20 130 24 221 SS 5/16"dia lag bolt,5-1/2"length Weight Distribution array dead load 3.5 psf PAC/,���O,p load per attachment 32.2 lb * O Subject roof has one layer of shingles. Panels mounted flush to roof no higher than 6 inches above roof surface. A Ralph Pacifico, PE N� Professional Engineer �86182 Ralph feer NY 088182/NJ 24G�E 44306/FL 87297 GREENLOGIC° ENERGY GreenLoglc,LLCApproved Stroup,Debra 1205 Tuthill Road Extension Southold,NY 1.1971 Surface#A: Total System Size:9.810kW 1 circuit of 10 on a 20A breaker 1 circuit of 10 on a 20A breaker 1 circuit of 10 on a 20A breaker Azimuth:216" Pitch:40" Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-E20-327-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:25'10"X 20'10 7/8" Surface:32'4"X 21'8" Magic#:Invisimount Legend: ® 30 SunPower 327W Panels ® SunPower Invisimount Rail • 72 Quick Mount E Lag B 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: �OF NEW r PAC/,c��,A� . O 066182 �O�ESStONP�� Drawn By:MA Drawing#1 of 5 Date:1/8/2020 REV:A Drawing Scale:3/16"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Stroup,Debra 1205 Tuthill Road Extension Southold,NY 11971 Surface#A: Total System Size:9.810kW 1 circuit of 10 on a 20A breaker 1 circuit of 10 on a 20A breaker 1 circuit of 10 on a 20A breaker Azimuth:216" Pitch:40" Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-E20-327-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:25'10"X 20'10 7/8" Surface:32'4"X 21'8" Magic#.Invisimount Legend: ® 30 SunPower 327W Panels SunPower Invisimount Rail • 72 Quick Mount E Lag B 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quid(Mount,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: o f-NE �P �H PACi��C 09 r ¢ �W r ��OA9 086182 S1 Drawn By:MA Drawing#2 of 5 Date:1/8/2020 REV:A Drawing Scale:3/16"=1.0' GREENLOGIC° ENERGY GreenLogic,LLC Approved Stroup,Debra 1205 Tuthill Road Extension Southold,NY 11971 Surface#A: Total System Size:9.810kW 1 circuit of 10 on a 20A breaker 1 circuit of 10 on a 20A breaker 1 circuit of 10 on a 20A breaker Azimuth:216" 1 Pitch:40" Monitoring System: \" SunPower Panel/Array Specifications: Panel:SPR-E20-327-E-AC 1 Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:25'10"X 20'10 7/8' Surface:32'4"X 21'8" 2 Magic#:Invisimount Legend: ® 30 SunPower 327W Panels SunPower Invisimount Rail 2 • 72 Quick Mount E Lag B B 2x10"Douglas Fir Rafter 16"O.C. Notes: 3 Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: 3 �SoF NE /C9 QN PAc,,cV�'p�� r* 'F r- Z cQ ?� v R�FESSIONP Drawn By:MA Drawing#3 of 5 Date:1/8/2020 REV:A Drawing Scale:3/16"=1.0' No Vent Pities Will Be Covered By The Solar Array G�GREENLOGIC° ENERGY LEGEND: AR -Access roof per R202 definitions RAP -Roof access point-to be away from RWV -Roof with valley. GreenLogic,LLC Approved overhead obstructions,doors. 18'minimum from valley Stroup,Debra windows,decks,fences,landscaping 1205 Tuthill Road Extension GA -Ground access area per R324.7.3 width AP -Access Pathway.36'minimum SVO -Smoke vent operation per Southold,NY 11971 to be same as AP as measured at eave width per R324.7.4 and R324.7.5 R324.7.7,18'minimum from ridge Total System Size:9.810kW 1 circuit of 10 on a 20A breaker 1 circuit of 10 on a 20A breaker 1 circuit of 10 on a 20A breaker Azimuth:216° Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-E20-327-E-AC 30 SunPower Racking:SunPower Invisimount 327W Panels Panel:61.39"X 41.18" Array:25'10"X 20'10 7/8" Surface:32'4"X 43'4" Magic#:Invisimount Legend: ® 30 SunPower 327W Panels — SunPower Invisimount Rail • 72 Quids Mount E Lag B 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Dyers:1 Height above Roof Surface:4" Materials Used:Quids Mount,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: LO El IM W c� �o 066. Meter . p9�FFSSION�� Drawn By:MA Drawing#4 of 5 Date:1/8/2020 REV:A Drawing Scale:1/16"=1.0' -CtGREENLOGIC° ENERGY GreenLogic,LLCApproved Stroup,Debra 1205 Tuthill Road Extension Southold,NY 11971 JCBNAIEFMU9 Total System Size:9.810kW 1 circuit of 10 on a 20A breaker - - 1 circuit of 10 on a 20A breaker 1 circuit of 10 on a 20A breaker Azimuth:216° Wow Lid R31 WIN LiSt CC Monitoring System: SunPower Pane!/Array Specifications: Panel:SPR-E20-327-E-AC cmtA uTiwnNtundlgElc&%WElackAulimnSad irg 72 __. .._-. _ Racking:Su a R SunPower Invis'mount Panel:61.39"X 41. �/76k7/S' Irgpitg 7L Array:25'10"X 20'10 7/8" %S8 &9'ft Fbad l$Saew 72 Surface:32'4"X 43'4" Magic#:Invisimount �.2i'FP1YfV11P1 72 Legend: ® 30 SunPower 327W Panels ® SunPower Invisimount Rail • 72 Quids Mount E Lag 2x10'Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: Of Nkk� N PAC/�ciC r- a W �• 9CFESSIO�P Drawn By:MA Drawing#5 of 5 Date:1/8/2020 REV:A Drawing Scale:1/16"=1.0'