HomeMy WebLinkAbout52562-Z yo��pF souryO!° Town of Southold
* * P.O. Box 1179
2. {�e 53095 Main Rd
°�i�a� Mei1 Southold, New York 11971
CERTIFICATE OF OCCUPANCY
No: 46966 Date: 04/10/2026
THIS CERTIFIES that the building SOLAR PANEL
Location of Property: 460 Paddock Way Mattituck, NY 11952
Sec/Block/Lot: 107.4-2.11
Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 12/16/2025
Pursuant to which Building Permit No. 52562 and dated: 12/18/2025
Was issued, and conforms to all of the requirements of the applicable provisions of the law.
The occupancy for which this certificate is issued is:
Roof-mounted solar panels on an existing barn as applied for.
The certificate is issued to: Patricia Homan
Of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL:
ELECTRICAL CERTIFICATE: 115625 1/27/2026
PLUMBERS CERTIFICATION:
Aut orize gnature
*of souyo TOWN OF SOUTHOLD
BUILDING DEPARTMENT
T SOUTHOLD, NY
o(y coupw*11
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit #: 52562 Date: 12/18/2025
Permission is hereby granted to:
Patricia M Homan
PO BOX 187
Peconic, NY 11958
To:
install roof-mounted solar panels on an existing barn as applied for.
Premises Located at:
460 Paddock Way, Mattituck, NY 11952
SCTM# 107.-4-2.11
Pursuant to application dated 12/16/2025 and approved by the Building Inspector.
To expire on 12/18/2027.
Contractors:
Required Inspections:
Fees:
SOLAR PANELS $100.00
CO - RESIDENTIAL $100.00
Total $200.00
I
--- — ---------------------
Building Inspector
NASSAU ELECTRICAL
SUFFOLK INSPECTORS
159 Route 25A, Building 1 Suite B
Miller Place, NY 11764
Telephone:631 495 8136 - Fax:631 509 4538 - E-Mail: Requests@SuffolkBEI.com
CERTIFICATE OF ELECTRICAL COMPLIANCE
Applicant: Green Logic Certificate No.: 115625
Rough In Inspection Date: Final Inspection Date: Jan 27,2026
Application No.: Building Permit No.: 52562
County Tax Map No.: 1000 107 4 2.11
This Certificate of Electrical Compliance is limited to the inspection and compliance of electrical equipment and/or work described
below,installed on behalf of the applicant named above,located at the premise of and not after the final inspection date ahove:
Owner: Patricia Homan
Site Location: 460 Paddock Way,Mattituck, NY 11952
Owner's Address(if different):
12 Residential 0 Indoor ❑Basement ❑Service ❑Shed
❑Commercial 0 Outdoor ❑First Floor ❑Pool ❑Hottub
❑New ❑Renovation ❑Second Floor ❑Attic ❑Garage
❑Addition ❑Survey 12 PV Solar ❑Generator ❑Conversion
❑Signs ❑Battery Storage ❑Safety Inspection Other:
INVENTORY
Single Phase Heat Duplex Recpt Ceiling Fixture Dual Func Breaker
Three Phase 0 Hot Water 0 GFCI Recpt 0 Wall Fixture 0 Smoke 0
Main Panel AC Cond Single Recpt Recessed Fixture CO Detect
Sub Panel AC Blower O Range Recpt LED Lighting Smoke CO Combo
Transformer Appliance Ckt Dryer Recpt Emergency Time Clock
Disconnect Switches Twist Lock Exit Fixtures Pumps
GFCI Breaker Heat Pump Electric Heat Pool Luminaire Exhaust Fan
Other Equipment:System Size:17.940 kW Qty:39 Desc:REC460AA Pure-RX Qty:39 Desc:EnPhase IQBX-80-M-US
The electrical work and/or equipment described above were inspected and was found to be in compliance with local,
state and national electrical code requirements and this office.
Applicant: Green Logic License No.: 43858-ME
Date Pn6jed✓Jan 27, 2026
MAR 3 '� 2026
Inspected By: Joe Coppola
Signature:
oF souryo�
TOWN OF SOUTHOLD BUILDING DEPT.
"cou 631-765-1802
INSPECTION
[ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] I SULATION/CAULKING
[ ] FRAMING / STRAPPING [ FINAL S0jR_?,,,
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL
REMARKS: a- 4-� Co
DATE -, INSPECTOR
D A M E S J. S T 0 U T A R C H I T E C T & Assoc .
2 G R E G L A N E EAST NORTHPORT N. Y. 631 - 8 58 9388
Post Install Letter
January 16, 2026
RE: Patricia Homan
460 Paddock lane
Mattituck, NY 11952
To Whom it may concern:
This letter is to confirm that as of this date, January 15, 2026 I, James J Stout, NYS
license 021633 have visually inspected the placement and installation of the roof top
solar panels at the above listed address. The solar panels have been installed as per
manufacturers' guidelines and specifications. The racking system design and
installation complies with all applicable codes. The installation was done as per the
approved Building Department plans.
The analysis of the documents supplied by the client relies on sound engineering
judgment and relevant experience. However, regardless of the professional's
qualifications or thoroughness of the investigation, preexisting conditions cannot
always be anticipated beyond the scope of direct observation. No additional
guarantees, whether expressed or implied, are provided regarding the professionals'
recommendations outlined in this letter.
This certification letter must be presented to the municipality within 120 days of the
issuance date to ensure compliance with safety procedures and continuity of service.
Thank you for your cooperation in this matter.
James J. Stout
�p�ED ARC
�Q 04 j
�21. 33 yDe� MA R 3 1 2026
F R NEB
FIELD INSPECTION REPORT DATE COMMENTS
FOUNDATION (1ST)
--------------------------------------
FOUNDATION (2ND) - - - - -_ _ ---
Q
ROUGH FRAMING&
PLUMBING
1
1
r
INSULATION PER N.Y. -- - - - �
STATE ENERGY CODE
FINAL
ADDITIONAL COMMENTS
Clpz,
opat
os I n + ucto (?-r-d
. Jz
c
b
TOWN OF SOUTHOLD-BUILDING DEPARTMENT
z
x
Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
°� • � :' Telephone (631) 765-1802 Fax (631) 765-9502 litti)s://www.southoldtowniiy.iYov
Date Received
APPLICATION FOR BUILDING PERMIT
For Office Use Only J
." 16
PERMIT N0. Building Inspector: C
Applications and forms must be filled out in their entirety. Incomplete
applications will not be accepted. Where the Applicant is not the owner,an ,� c
Owner's Authorization form(Page 2)shall be completed.
Date:12/10/2025
OWNER(S) OF PROPERTY:
Name: Patricia Homan SCTM# 1000- 107-4-2.11
Project Address: 460 Paddock Way, Mattituck, NY 11952
Phone#: 631-445-0106 Email: homanpatricia@gmail.com
Mailing Address: PO Box 187, Peconic, NY 11958
CONTACT PERSON:
Name:Barbara - GreenLogic LLC
Mailing Address:97 North Sea Road, Southampton, NY 11968
Phone#:631-771-5152 x117 Email:Barbara@Greenlogic.com
DESIGN PROFESSIONAL INFORMATION:
Name:James J. Stout Architect & Associates
Mailing Address:2 Greg Lane, East Northport, NY 11731
Phone#:631-858-9388 Em ail7:stouthub@jamesstoutarch.com
CONTRACTOR INFORMATION:
Name:GreenLogic LLC
Mailing Address:97 North Sea Road, Southampton, NY 11968
Phone#:631-771-5152 1 Email:AM@Greenlogic.com
DESCRIPTION OF PROPOSED CONSTRUCTION
❑New Structure ❑Addit'on BAlteration ❑Repair ❑Demolition Estimated Cost of Project:
0Other Solar Panels am $ 62,000
Will the lot be re-graded? ❑Yes BNo Will excess fill be removed from premises? ❑Yes RNo
1
{r.
PROPERTY INFORMATION
Existing use of property: single family residence Intended use of property: single family residence
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
this property? ZYes ONO IF YES, PROVIDE A COPY.
® Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by
Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are
punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law.
Application Submitted B GreenLogic LLC
pp y(print name): BAuthorized Agent ❑Owner
Signature of Applicant: Dater I t1l
STATE OF NEW YORK)
SS:
COUNTY OF Suffolk )
Nesim Albukrek
being duly sworn, deposes and says that(s)he is the applicant
(Name of individual signing contract)above named,
Contractor
(S)he is the
(Contractor,Agent,Corporate Officer,etc.)
of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief; and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
10 day of 20,E
Notary Public
BARBARA A CASCIOTTA
Notary Public-State of New York
PROPERTY OWNER AUTHORIZATION No.01 CA4894969
Oualiified in Suffolk County
(Where the applicant is not the owner) Commission Expires May 11,2027
I, "I A�t'Yl cA-4G- '` JYYtG� ✓1 residing at �IL�; �ll �OC�L Lys
do hereby authorize GreenLogic LLC to apply on
ehalf to the Topwn�of Southold Building Department for approval as described herein.
IVY
C._ Q�—
2--c
Owner's Signature i Date
I(. c- t�m a a-)
Print Owner's Name
2
GREENLOGICO
ENERGY
December 10, 2025
Town of Southold
Building Department
Town Hall
53095 Route 25
Southold, NY 11971
Project Info:
Patricia Homan
460 Paddock Way
Mattituck, NY
1000-107-4-2.11
Dear Building Inspector:
Please find attached a building permit application to install a roof mounted solar photovoltaic(PV)
electric system for the above referenced property.There was a solar system on the roof that was
removed by the prior owner.
In connection with this application, please find attached:
• Building Permit application with owner authorization
• 2 Surveys of the Premises
• 4 Engineer's Reports
• 2 Three Line Electrical Drawings
• 2 Spec. sheets of the solar panels/inverters
• 2 Spec. sheets for Racking System
• 2 Spec. sheets for Monitoring System
• GreenLogic Suffolk County Home Improvement License
• GreenLogic Certificate of Liability Insurance
• GreenLogic Certificate of Worker's Compensation Insurance Coverage
• Installation Manager's Master Electrician's License
• Check for$200($100 Building Permit/$100 CO)
Please let us know if you need anything else in connection with this application.
Yours truly,
`gatba w ewciottac
Barbara Casciotta
Account Manager
Barbara@Greenlogic.com
GREE65lt 7:Lt5;15,2�eXL,LUogic.com Tel: 631.771.5152 Fax: 631.771.5156
SOUTHAMPTON ROSLYN HEIGHTS
97 North Sea Rd., Suite 3 200 S. Service Rd., #104C
Southampton, NY 11968 Rosyln Heights, NY 11577
GREENLOGIC®
ENERGY
March 26, 2026
The Town of Southold
Building Department
54375 Route 25
P.O. Box 1179
Southold, NY 11971
Project Info:
Building Permit No. 52562
Patricia Homan
460 Paddock Way
Mattituck, NY
To the Building Inspector:
Enclosed please find the Electrical Certificate and Engineer's Certification Letter for the
above referenced address. Can you please close the building permit and send the
Certificate of Occupancy after inspection? Please let me know if you have any questions
about the installation.
Sincerely,
J3a bww CaryciaUa
Barbara Casciotta
Account Manager
Barbara@Greenlogic.com MAR 3 2026
631-771-5152 Ext. 117
GREENLOGIC LLC • www.GreenLogic.com Tel: 631.771.5152 Fax: 631.771.5156
SOUTHAMPTON ROSLYN HEIGHTS
97 North Sea Rd., Suite 3 200 S. Service Rd., #104C
Southampton, NY 11968 Rosyln Heights, NY 11577
\ L.s•I:r Lot 9
--t-30107:--
WAY` ` S6s.�`s
�=250
• �� �sso q p
gyp no 05�2 00c
�•` Lot t3 ! - 'I ;`o+ �
c o Lot 10 m
N I [DO
is
rn
4 t 66i 4S
� In
7.
rn
LQ
tn
I �
lot
W y
l
A
J. r 1 '"r; a 1 \\
r; R
yy L _ 45g9'� C�
L o 1 12 � A C 1� � �°r a'od _.�r`�_
O5 t t o LA
1 tT c� Arco=5 ` I g\ NOTE
1 5 ELEVATIONS SHOWN HEREON ARE FROM TOPOE
MAPS PREPARED BY US REFERENCED TO K6_Y-1
\ �.. �O
tt6 iZ ` AND ARE SUBJECT TO FIELD VERIFICATION
�61 I t2O.4t' 298.19 \
S8s Hc8 W , now or formerly �e' _ YOUNG & YOUNG
SEPT 14,1994
ri/f -o Yt►t11111 \ OCT 4,1994 s.f,et
Dean
)0 JAI
ALLAN DICKERSON a CHARLOTTE DICKE
wfFOLK COUNTY DEPARTMENT OF HEALTH sER,ICt- LOT NO. 12, WOLF PI'POND ESTATES"
FOR APPROVAL OF CONSTRUCTION ONLY ,
MATTITUCK
SATE HS REF. NO.
FOUND AL STAKE FOUND
FILED IN THE OFFICEOFTHE CLERIC OF „P�YFD SCUTHOLO
DN DUNE 21,1990 AS FILE NO 8963 _
SE PT+CIi•at15�i4C[Si:�':O.S.WJ'►+O.rM ufREOM I -l...t. . -
w�eao°+°oa.alrcorAowoT,uas i = ICO
AUG, 16, 1990
o�
APP 0 ED AnS NOTED
O - B.RR0
FEE r BY: 4 OCCUPANCY OR
NOTIFY BUILDING DEPARTMENT AT ��� lg A ■u,������
631-765-1802 8AM TO 4PM FOR THE
FOLLOWING INSPECTIONS:RE-T
i. FOUNDATION WITHOUT CERTIFICATE
FOUNDATIONVA/Cl r1r�iA�O
FOR PnURcL CONCRF��-2. ROUGH- OF OCCUPANCY
FRAMING& F'LU,�,t;; :a
3. INSULATION
4. FINAL-CONSTRUCTION MUST
BE COMPLETE FOR C.O.
ALL CONSTRUCTION SHALL MEET THE
REQUIREMENTS OF THE CODES OF NEW
YORK STATE. NOT RESPONSIBLE FOR
DESIGN OR CONSTRUCTON ERRORS
COMPLY WITH ALL CODES OF
NEW YORK STATE &TOWN CODES ELECTRICAL
AS REQUIRED AND C DITIONS OF INSPECTION REQUIRED
SOUTHOLD OWN ZBA
SDUTNO TOWN PLANNING BOARD
SOUTH TOWN TRUSTEES
SIX
HPC
.J A M E S J. S T 0 U T A R C H I T E C T & Assoc .
2 G R E G L A N E E AST NORTHP0R TN. Y. 631 - 8 58 9388
Letter of Certification
November 13, 2025
RE: Homan Residence
460 Paddock Lane
Mattituck, NY 11952
To Whom It May Concern:
I, James J. Stout, registered architect NYS license number 021633 would like to
submit the following. I have inspected and analyzed the roof structure at the above-
mentioned address and have determined the structure and the panel attachment to
be adequate to support the new additional load imposed by the proposed solar panel
system and is in compliance with 130mph wind design load as per 2020 Residential
code of NYS (RCNYS), 2020 building code of NYS (BCNYS) residential code, 2020
Energy conservation construction code of NYS (ECCCNYS) and the IRC 324 and
2014 NEC.
The existing 2" x 6" @ 16" roof rafters will provide the required support. The weight of
the modules are no more than 5 lbs. per square foot. Modules are to be flush mount,
no higher than 6 inches above roof.
Design Loads:
Existing Roof—Dead Load 11# SF
Snow Load Live Load 20#SF
Solar Panel & Racking 4#SF
Total 35
#SF
ED ARC
Q ��' �►
.y� 02163'3 y�Q
-G�GREENLOGIC`�
ENERGY
GreenLogic,LLC Approved
Homan,Patricia
460 Paddock Lane
Mattituck,NY 11952
Surface#A:
Total System Sine: 17.940kW
1 circuit of 10 on a 20A breaker
1 circuit of 9 on a 20A breaker
1 circuit of 10 on a 20A breaker
1 circuit of 10 on a 20A breaker
Azimuth: 120'
Poch:
Monitorinrin
g System: 2
EnPhase
Panel/Array Specifications:
Panel:REC460AA PURE-RX
Racking:IronRidge
Panel:68.0"X 47.4"
Array:79'8 7/8"X I 11"
Surface:84'8"X 13'8"
Legend:
39 EC Alpha Pure-RX 460W
IQ8X Microlnverters
Iron Ridge XR-100 Racking
• 94 IronRidge Flash Foot 2
8 8 24"Douglas Fir Rafter 16"O.C.
Notes:
Number of Roof Layers:1
Height above Roof Surface:4"
Materials Used:IronRidge,REC,EnPhase
Added Roof load of PV System:2.32psf
Engineer/Architect Seal:
ZAeD AHC
r
7 a7 t 63� -40
�QF.-NE'N
Drawn By:MA Drawing#1 of 5
Date: 11/10/2025 REV:A
Drawing Scale:3/32"=1.0'
GREENLOGIC"
ENERGY
GreenLogfc,LLC Approved
Homan.Patricia
460 Paddock Lane
Mattituck,NY 11952
Surface#A:
Total System Size: 17.940kW
1 circuit of 10 on a 20A breaker
1 circuit of 9 on a 20A breaker
1 circuit of 10 on a 20A breaker
1 circuit of 10 on a 20A breaker
Azimuth:120"
Monttrin
Monitoring System: 2
EnPhase
Panel/Array Specifications:
Panel:REC460AA PURE-RX
Racking:IronRidge
Panel:68.0"X 47.4"
Array:79'8 7/8"X 1 V 11"
Surface:84'8"X 13'8"
Legend:
® 39 REC Alpha Pure-RX 460W
39 IQ8X Microlnverters
p Iron Ridge XR-100 Racking
• 94 IronRidge Flash Foot 2
8 8 M"Douglas Fir Rafter 16"O.C.
Notes:
Number of Roof Layers: 1
Height above Roof Surface:4"
Materials Used: IronRidge,REC, EnPhase
Added Roof load of PV System:2.32psf
Engineer/Architect Seal:
REO c --
c��y S�
Drawn By-.MA Drawing#2 of 5
Date- 11/10/2025 REV:A
Drawing Scale:3132"=1.0'-
-G�GRUNLOGIC`
_NERGY
Green Logic,LLC Approved
Homan,Patricia
460 Paddock Lane
Mattituck,NY 11952
Surface#A:
Total System Size: 17.94okW
1 circuit of 10 on a 20A breaker
1 circuit of 9 on a 20A breaker
1 circuit of 10 on a 20A breaker
1 circuit of 10 on a 20A breaker
Azimuth:120°
Poch:
Monitorinrin
g System: 2
EnPhase
Panel/Array Specifications:
Panel:REC460AA PURE-RX
Racking:IronRidge
Panel:68.0"X 47.4"
Array:79'8 7/8"X 1I'll"
Surface:84'8"X IT 8"
1X 1 2 3 Legend:
1 2 3 39 Q8X Micrrolnverters 460W
Iran Ridge XR-100 Racking
4 3 • 94 IronRidge Flash Foot 2
�ILZ8 24"Douglas Fir Rafter 16"O.C.
Notes:
Number of Roof Layers:1
Height above Roof Surface:4"
Materials Used:IronRidge,REC,EnPhase
Added Roof load of PV System:2.32psf
Engineer/Architect Seal:
SPED c
S]
r
'rF QFl NE'N i
Drawn By:MA Drawing#3 of 5
Date: 11/10/2025 REV:A
Drawing Scale:3/32"=1.9
No Vent Pipes Will Be Covered By The Solar Array G�GREENLOGICO
ENERGY
Legend: GreenLogrc,LLC Approved
Homan,Patricia
AR-Access Roof AP-Access pathway,36"minimum width SVO—Setback at ridge 460 Paddock Lane
per R202 definitions per R324.6.1 as per R324.6.2.1 Mattducik,NY 11952
Total System Size: 17.940kW
1 circuit of 10 on a 20A breaker
1 circuit of 9 on a 20A breaker
1 circuit of 10 on a 20A breaker
1 drcud of 10 on a 20A breaker
Aamuth: 120"
Monitoring System:
EnPhase
Panel/Array Specifications:
Panel:REC460AA PURE-RX
Racking:IronRidge
❑ a ❑ IAP Panel: :8.0"X 4 39'
AP Surface:84'8"X 39'8"
Legend:
39 REC Alpha Pure-RX 460W
API :AP 0 39 IQ8X Microlnverters
— Iron Ridge XR-100 Racking
L----------------- — — ----------------I • 94 lronRidge Flash Foot 2
SvO
_ Svo
__ SvO — 8 8 2x6"Douglas Fir Rafter 16"O.C.
Notes:
Number of Roof Layers:1
Height above Roof Surface:4"
Materials Used:IronRiidge,REC,EnPhase
Added Roof load of PV System:2.32psf
Engineer/Architect Seal:
39 REC 46OW
Panels Meter C '
t
f 0 163� �P
Drawn By:MA Drawing#4 of 5
Date: 11/10/2025 REV:A
Drawing Scale: 1116"=1.0'
GREENLOGIC`'
FNFRGY
GreenLogic,LLC Approved
Homan,Patricia
460 Paddock Lane
JOB MATERIAL LIST Mattitudk,NY 11952
Total System Size: 17.940M
1 circuit of 10 on a 20A breaker
1 circuit of 9 on a 20A breaker
1 circuit of 10 on a 20A breaker
1 circuit of 10 on a 20A breaker
Azimuth:120"
Material list tV. Rail Material list t( Monitoring System:
EnPhase
Pand/Array Specifications:
Cast Aluminum Mounting Block w/Black Aluminum Flashing 94 Panel:REC460AA PURE-RX
5/16"x0.75"Fender Washer 94 Racking:IronRidge
Panel:68.0"X 47.4"
5/16"x4.75"Hex-Head lag Screw 94 Surface:84'8"X 39'8"
Legend:
39 REC Alpha Pure-RX 460W
39 IQ8X Microinverters
Iron Ridge XR-100 Racking
• 94 IronRidge Flash Foot 2
8 8 M"Douglas Fir Rafter 16"O.C.
Notes:
Number of Roof Layers:1
Height above Roof Surface:4"
Materials Used:IronRidge,REC,EnPhase
Added Roof load of PV System:2.32psf
Engineer/Architect Seal:
`cPEc ARC
, , 3
4 Y •l
t
02 633
i
'rF OF NEB 1
Drawn By:MA Drawing#5 of 5
Date: 11/10/2025 REV:A
Drawing Scale:1/16"=1.0'
EQUIPk�ENT------------------------- EXISTING SERVICE
PV—SA-- A.. AC—COMBINER PANEL 120/240, 1 PH, 3W
k _ �j
t • AC-CM-B-1 t
N I • • • � � `' (PV LOADS ONLY)
IV , 200A KWH
I
I
QV—SA-2 Ai I
. . . A e N
BKR-1 AC—DSC-1 ,
AC DISCONNECT
I
11
k I:?KR-2 � k
(` PV—SA-3 I
( . . .
• • • F--- 8KR-3
VAIN
k III BKR-4 ,
FUSED A 8. I
PV—SA-4 III
k N ,
• • • IIICI
(EGC
hi
TYPICAL PV MODULE WITH I l 1 1 I
INTEGRAL DC/AC INVERTER IIII EGC I
I IIII I I I I ..
IIII I I I EXISTING AC PANI4IEXISTING
17.940kW DC IIII I I I GEC
14.976 kW AC I_ _�___ ___ _ _.__........
.._ ___ GEC _——————
PROPOSED 3-LINE ELECTRICAL DIAGRAM
REVISIONS
Homan, Patricia LOGIC„'
460 Paddock Lane - ENERGY
Mattituck, NY 11952 ELIMINATING THE COST OF ENERGY
1.) INITIAL SUBMITTAL WITH APPLICATION
Page 1 of 3 Drawing No: 3LD1 Revision: 1 Revised: 10/22/2025
Account#9626522552
Meter#80340163
EQUIPMENT& COMPONENT SCHEDULE
TAG DESCRIPTION SPECIFICATION
PV-SA-1 PV SUB-ARRAY REC460AA Pure-RX ENPHASE IQ8X-80-M-US, 1-CIRCUIT OF 10-MODULES
PV-SA-2 PV SUB-ARRAY REC460AA Pure-RX EN PHASE IQ8X-80-M-US, 1-CIRCUIT OF 10-MODULES
PV-SA-3 PV SUB-ARRAY REC460AA Pure-RX EN PHASE IQ8X-80-M-US, 1-CIRCUIT OF 10-MODULES
PV-SA-4 PV SUB-ARRAY REC460AA Pure-RX I ENPHASE IQ8X-80-M-US, 1-CIRCUIT OF 9-MODULES
ELECTRICAL LOAD SUMMARY
AC CIRCUITS
TAG POWER, MAX VOLTAGE MAX. AC VOLTAGE, NOMINAL
RANGE CURRENT
PV-SA-1 3800 WATTS 211-264 VAC 19.75 A AC 240 V, AC
PV-SA-2 3800 WATTS 211-264 VAC 19.75 A AC 240 V, AC
PV-SA-3 3800 WATTS 211-264 VAC 19.75 A AC 240 V, AC
PV-SA-4 3420 WATTS 211-264 VAC 17.77 A AC 240 V, AC
PROPOSED EQUIPMENT SPECIFICATIONS
REVISIONS
Homan, Patricia LOGICO'
460 Paddock Lane C�4� :_NLR(
Mattituck, NY 11952 ELIMINATING THE COST OF ENERGY
1.) INITIAL SUBMITTAL WITH APPLICATION
Page 2 of 3 Drawing No: 3LD1 Revision: 1 Revised:10/22/2025
Account#9626522552
Meter#80340163
EQUIPMENT& COMPONENT SCHEDULE
TAG DESCRIPTION SPECIFICATION
AC-CMBP AC COMBINER PANEL 250V, 200A, NEMA-1, 1-PH, 3-WIRE
BKR-1 CIRCUIT BREAKER, PV-SA-1 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A
BKR-2 CIRCUIT BREAKER, PV-SA-2 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A
BKR-3 CIRCUIT BREAKER, PV-SA-3 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A
BKR-4 CIRCUIT BREAKER, PV-SA-4 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A
AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 250V, 100A, NEMA-1, FUSED; FUSE RATING: 100A
CONDUCTOR SCHEDULE
TAG TYPE CONDUIT AWG. / EGC
A USE-2/PV/UF 3/4" PVC-40 12 / 6
B THWN-2 2" PVC-40 4 / 6
C THWN-2 2" EMT 4 / 6
1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS.
2.) ELECTRICAL CONDUIT TO BE MIN. PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS.
3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE RE-
QUIREMENTS.
4.) NOTE:GROUNDING ELECTRODE CONDUCTOR TO BE#6 COPPER.
PROPOSED EQUIPMENT SPECIFICATIONS
REVISIONS
Homan, Patricia q zE N LOGIC
460 Paddock Lane tat
Mattituck, NY 11952 ELIMINATING THE COST OF ENERGY
1.) INITIAL SUBMITTAL WITH APPLICATION
Page 3 of 3 Drawing No: 3LD1 Revision: 1 Revised: 10/22/2025
SOLAR'S MOST TRUSTED REC
/t;
REE ALPHA
PURE-RX SERIES
DATASHEET ..........
- A MODULE CURRENT
COMP/MBLE
r
°^`• a rW f �.1� i7,,'� '�� � r. � r .n111.A-•A'1A:w.'•.Y .1� � — i .y...� '.
' _ • '+'QrV'•Sf
. . MAX.EFFICIENCY
. • •, � R E C
Measurements In Inches
88 half-cut bifacial REC heterojunction cells _
Cell Type with gapless technology
Glass 0.13 in.solar glass with anti-reflective surface treatment
in accordance with EN12150
Backsheet Highly resistant polymer(Black) (,= 66.9
Frame Anodized aluminum(Black)
Junction Box 4-part,4 bypass diodes,
IP68 rated,in accordance with IEC 62790
Staubli MC4 PV-KBT4/KST4(12AWG)
Connectors1 g
in accordance with IEC 62852,IP68 only when connected r 63
Cable 12 AWG solar cable,66.9 in.+66.9 in.
in accordance withEN50618
Dimensions 68 x 47.4 x 1.2 in.(22.4 ft')
-
Weight 50 lbs o.v 211 go.r z
v
Origin Made in Singapore
J
O
_ n i
PRODUCT CODE�_RECxxxAAPu-e.RX'" " ,, r,.� IFICATIONS 3
Power Output-PMax(WI) 450 460 470 IEC 61_'15:2021;IE.C61730:2016;UL61730 A
Watt Class Sorting-(W) 0/+10 0/+10 t�,10 15011925-2 Ignitability(EN 13501-1 Class E)
IEC 62716 Ammonia Resistance °
Nominal Power Voltage-V,jV) 54.3 54.9 SSA IEC61701 SaltMlst(5M6} v
Nominal Power Current-1,(A) 829 8.38 8.49 IEC 612152016 Hailstone(35mm)
UL61730 Fire Type 2
F Open Circuit Voltage-Voc(V) 6S.1 65.3 65.6 ISO 14001;ISO9001;IEC45001;IEC62941
Short Circuit Current-I5f(A) 8.81 8.88 8.95
Power Density(W/ft') 20.1 20.5 21.0 DvE nJ6 E takel�uvayLn
Panel Efficiency(°k) 21.6 22.1 22.6 T= Inte+tek wyweeeY
ems:rr,•W,,,E
Power Output-Pnux(Wp) 343 350 358
~o Nominal Power Voltage-VMPP(V) 512 51.7 52.2
z Nominal Power Current-IMp,(A) 6.70 6.77 6.86
Open Circuit Voltage-Voc(V) 61.3 61.6 61.8 ""
Short Circuit Current-Isc(A) 7.11 7.17 7,23 i�IIIAWAW
Standard REC ProTrust
Values at standard tesc conditions(STC,air mass AM 1.5.irradiance 1000 W/m',temperature 77"F(25'C)),based on a production soread with a tolerance of P,_,Vor&I,m3%
within one watt class.Nominal module operatingtemperature(NMOT:air mass AM IS.Irrad:ance 600 W/m',temperature 68T(20°C),w;ndspeed33 ft/s(I m/s)).'Where xxx Installed by an REC No Yes Yes
indicates the nominai power class(Pvsr)at STC above. Certified Professional
TEMPERATURE RATINGS* System Size All Q51cw 25-5ookw
Operational Temperature -40'F-185'F Nominal Module Operating Product Warranty(yrs) 20 25 25
System Voltage 1000 V 44'C t 2°C Power Warranty(yrs) 25 25 25
y g Temperature
Maximum Test Load(front) +7000 Pa(146lb/ft2) ° Labor Warranty(yrs) 0 25 10 N
Temperature coefficient of PMnx -0.24/%/IC CD Test load(rear) 4000 Pa{83.416/ft2) Temperature coefficient of Voc -0.24%/K Power in Year 1 98% 98% 98%
Max Series Fuse Rating 25 A Temperature coefficient of Isc 0.04%/K Annual Degradation 0.25% 0.25% 0,25% v
Max Reverse Current 25A 'The temperature coefficients stated arelinearvelues Power in Year 25 92% 92% 92% y
*See installation manual for mounting instructions 05
Design load-Test load/1.5(safety factor) ,. The RFC Pr,,Tu,Warrarty is only available m panels purchased through an REC
DELIVERY INFORMATION CeKifiedSolarProfesstonalmstallerWarrantyconditionsapply.See www.recgroup o
"�::.. corn for more details rV
Panels per Pallet 33 0
Panels per 40 ft GP/high 594(18 Pallets)
cube container LOW LIGHT BEHAVIORSlip Ma
Panels per 53 ft truck 792(24 Pallets)
Available'i orn Typical low irradiance performance of module at STC: Cr
s G
w
t 1p R » w Irradiance(W/m') M ,M
Founded in 1996,REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean,affordable REC Solar PTE.LTD.
solar power.As Solar's Most Trusted,REC is committed to high quality,innovation,and a low carbon footprint in the solar materials and solar 20Tuas South Ave.14REC
panels it manufactures.Headquartered In Norway with operational headquarters in Singapore,REC also has regional hubs in North America, Singapore 637312 ....
Europe,and Asia-Pacific. post@recgroup.com
www.recgroup.com
ENPHASE.
����11�11'111111N I'I'9
IMrI i'
1Q8X Microinverter Easy to install
Our newest I08 Series Microinverters are the industry's first microgrid-forming*,software-defined Lightweight and compact with plug-
microinverters with split-phase power conversion capability to convert DC power to AC power and-play connectors
efficiently.The brain of the semiconductor-based microinverter is our proprietary application- Power line communication(PLC)
specific integrated circuit(ASIC),which enables the microinverter to operate in grid-tied or between components
off-grid mode.This chip is built using advanced 55-nm technology with high-speed digital logic Faster installation with simple two-wire
and superfast response times to changing loads and grid events,alleviating constraints on battery cabling
sizing for home energy systems.
IQ8X Microinverter is the latest addition to this family,designed to support PV modules with high Nigh productivity and reliability
output DC voltage and cell counts,such as 80-half-cut cells,88-half-cut cells and 96-cells. Produces power even when the grid is
down*
More than one million cumulative hours
Enphase of testing
Class If double-insulated enclosure
Optimized for the latest high-powered
T. I PV modules
Part of the Enphase Energy System, IQ8 Series Microinverters redefine
I08 Series Microinverters integrate with reliability standards with more than one Microgrid-forming
the IQ Battery,IQ Gateway,and the million cumulative hours of power-on Complies with the latest advanced grid
Enphase App monitoring and analysis testing,enabling an industry-leading support
software. limited warranty of up to 25 years. Remote automatic updates for the
latest grid requirements
Configurable to support a wide range
of grid profiles
Meets CA Rule 21(UL 1741-SA)and IEEE
1547:2018(UL 1741-SB)
NOTE:
Connect PV modules quickly and easily IQ8 Series Microinverters are UL Listed I08 Series Microinverters cannot be mixed with
to the IQ8 Series Microinverters with as PV rapid shutdown equipment and previous generations of Enphase microinverters(107
integrated MC4 connectors. conform with regulations when installed Series,IQ6 Series.and so on)In the same system.
according to the manufacturer's 10 Microinverters ship with default settings that
instructions. meet North Americas IEEE 1547 interconnection
standard requirements.Region-specific
adjustments may be requested by an Authority
Having Jurisdiction(AHJ)or utility representative,
according to the IEEE 1547 interconnection
*Meets UL 1741 only when installed with IQ System Controller 2 or 3. standard.An IQ Gateway is required to make these
changes during installation.
®2024 Enphase Energy.All rights reserved.Enphase,the a and CC logos,IQ and certain other marks listed at
https;/iflnjhasccom/tradomarK-usago-,guid@lines are trademarks of Enphase Energy,Inc,in the U.S.and other countries.
Data subject to change. 108X-MC4-DSH-00185-3.0-EN-US-2024-02-12
IQBX Microinverter
INPUT DATA(OCI UNIT r. SO
Commonly used module pairings' w 320-540
Module compatibility _ To meet compatibility,PV modules must be within the following maximum input DC voltage and maximum module 1_
Module compatibility can be checked at ht(ps_//enphase..pom/installers/microinverter /calculator
MPPT voltage range V 43-60
Operating range V 25-79.5
Minimum and maximum start voltage V 30-79.5
Maximum input DC voltage v 79.5
Maximum continuous operating DC current A 10
Maximum input DC short-circuit current A 16
Maximum module I A 13
Overvoltage class DC port — 11
DC port backfeed current mA 0
PV array configuration Ungrounded array;no additional DC side protection required;AC side protection requires a maximum of 20 A per
branch circuit
OUTPUT DATA r: :r r :r r: VAC
Peak output power VA 384 366
Maximum continuous output power VA 380 360
Nominal grid voltage(L-L) V 240.split-phase(L-0.180° 208.single-phase(L-L),120"4
Minimum and maximum grid voltage 2 V 211-264 183-229
Max.continuous output current A 1.58 1.73
Nominal frequency Hz 60
Extended frequency range Hz 47-68
AC short circuit fault current over three cycles Arms 2.70
Maximum units per 20 A(L-L)branch circuit' — 10 9
Total harmonic distortion °% <5
Overvoltage class AC port — III
AC port backfeed current mA 18
Power factor setting — 1.0
Grid-tied power factor(adjustable) — 0.85leading...0.85lagging
Peak efficiency % 97.3 97.0
CEC weighted efficiency % 96.5 96.5
Nighttime power consumption mw 26 12
MECHANICAL DATA
Ambient temperature range -40°C to 65°C(-40°F to 149°F)
Relative humidity range 4%to 100%(condensing)
DC connector type Staubli MC4
Dimensions(H.W•D);Weight 212 mm MY).175 mm(6.9")•30.2 mm(1.2");1.1 kg(2.43 lb)
Cooling Natural convection-no fans
Approved for wet locations;Pollution degree Yes;PD3
Enclosure Class II double-insulated,corrosion-resistant polymeric enclosure
Environmental category;UV exposure rating NEMA Type 6;outdoor
COMPLIANCE
CA Rule 21(UL 1741-SA),UL 62109-1,IEEE 1547:2018(UL 1741-SB),FCC Part 15 Class B,ICES-0003 Class 8,CAN/CSA-C22.2 NO.107.1-01.
Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017,NEC 2020,and NEC 2023 section 690.12 and
C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's instructions.
(1)No enforced DC/AC ratio.
(2)Nominal voltage range can be extended beyond nominal if required by the utility.
(3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area.
(4)108X is not certified for use with Enphase Three Phase Network Protection Relay(NPR-3P-208-NA)and is,therefore,designed IQSX-MC4-DSH-00785-3.0-EN-US-2024-02-12
for single-phase operation only.Check with the local utility requirements if you wish to install single-phase inverters across three phases.
Do�� She�g
Networking
En�������������� 0��� ���������� The�noha�e|[!�nvov� oonnnounioationngatevvay
phase ��� ��° = =�~ ��'' ^
- ~ delivers solar production and energy consumption
data toEnphaaeEn|ighten= monitoring and analysis
software for comprehensive, remote maintenance and
management of the Enph8se |OSystem.
With integrated revenue grade production metering
and optional consumption monitoring, Envoy|Oisthe
platform for total energy management and integrates
with the EnphaSeEnSernb|e"and the Enpha3e |O
Battery".
Smart
' Enables web-based monitoring
ENPHASE and control
' Bidirectional communications for
remote upgrades
'Supports power export limiting and
zenooxportupp|iusUonx
Simple
' Easy system configuration using
snphuse Installer Too|kit~mobile app
' Flexible networking with wi'n.
Ethernet,orcellular
Reliable
' Designed for installation indoors
or outdoors
Five-year warranty
CERTIFIED
_ ��U���A� ����
To learn more about Enphaoe offerings,visit emphama.com *�� ��v�"PHASE,
Enphase IQ Envoy
MODEL NUMBERS
Enphase IQ Envoy' Enphase IQ Envoy communications gateway with integrated revenue grade PV
ENV-IQ-AMl-240 production
metering(ANSI C12.20+/-0.5%)and optional consumption monitoring(+/-2.5%).
Includes
one 200A continuous rated production CT(current transformer).
ACCESORIES(Order Seperately)
En hale Mobile Connect'" Plug and la industrial grade cellular
p g play' q (alai modem with data plan for systems up to 60
CELLMODEM-M1 (4G based LTE-M/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin
CELL.MODEM-MI-B(4G-based 1_TE-M1/5-year data plan) Islands,where there is adequate cellular service in the installation area.)
Consumption Monitoring CT Split-core consumption CTs enable whole home metering.
CT-200 SPLIT
Ensemble Communications Kit Installed at the IQ Envoy.For communications with Enphase Encharge"storage
COMMS-KIT-01 and Enphase Enpower"smart switch.Includes USB cable for connection to IQ
Envoy or Enphase IQ Combiner"and allows wireless communication with Encharge
and Enpower.
POWER REQUIREMENTS
Power requirements 120/240 VAC split-phase.
Max 20 A overcurrent protection required.
Typical Power Consumption 5W
CAPACITY
_.__ _...-_...__.__
Number of microinverters polled Up to 600
MECHANICAL DATA
Dimensions(WxHxD) 21.3 x 12.6 x 4.5 cm(8.4"x 5 x 1.8')
Weight 17.6 oz(498 g)
Ambient temperature range -40'to 65'C(-40°to 149'F)
-40°to 46"C(-40"to 115`F)if installed in an enclosure
Environmental rating IP30.For installation indoors or in an NRTL-certified,NEMA type 3R enclosure.
Altitude To 2000 meters(6,560 feet)
Production CT Limited to 200A of continuous current/250A OCPD- 72kW AC
Internal aperture measures 19.36rnrn to support 250MCM THWN conductors(max)
UL2808 certified for revenue grade metering
Consumption CT For electrical services to 250A with parallel runs up to 500A
Internal aperture measures 0.84"x 0.96"(2 ",33mm x 24.38mm)to support
3/0 THWN conductor
UL2808 certified,for use at service entrance for services up to 250Vac
INTERNET CONNECTION OPTIONS
integrated Wi Fi 802.11b/g/n
Ethernet 802.3,Cat5E(or Cat 6)UTP Ethernet cable(not included)
Mobile CELLMODEM-M1 (4G)or CELLMODEM-M1-B;(4G).Not included.Note that an
Enphase Mobile Connect cellular modem is required for all Ensemble installations.
COMPLIANCE
Compliance UL 61010-1
CAN/CSA C22.2 No.61010 1
47 CFR,Part 15,Class B,ICES 003
IEC/EN 61010-1:2010,
EN50065-1,EN61000-4-5;EN61 0 00-6-1,EN61 00 0-6-2
Metering:ANSI C12.20 accuracy class 0.5(PV production only)
To learn more about Enphase offerings,visit enphase.com V E N P H AS E.
c5)2021 Eriphase Energy,All rights reserved Enphase,;he Enphase logo,IQ Envoy,and other trademarks or service names are the trade.
marks of Enphase Energy,Inc.Data subject to change.06 30 2021
IRONRIDGE XR Rail° Family
Solar Is Not Always Sunny
Over their lifetime, solar panels experience countless
extreme weather events. Not just the worst storms in years, WAh
but the worst storms in 40 years. High winds capable of
ripping panels from a roof, and snowfalls weighing
enough to buckle a panel frame.
XR Rails® are the structural backbone II
preventing these results. They resist uplift,
protect against buckling and safely °
and efficiently transfer loads into the
building structure. Their superior
spanning capability requires fewer
roof attachments, reducing the �m ;
J �
number of roof penetrations
3M� y n T ,Mhy E
and the amount of , "
installation time.
3 is
y
Force-Stabilizing Curve
N Sloped roofs generate both vertical and lateral
s forces on mounting rails which can cause them to
bend and twist.The curved shape of XR Rails®
`""` - is specially designed to increase strength in both
directions while resisting the twisting.This unique
;r r , feature ensures greater security during extreme
weather and a longer system lifetime.
PIK
��sr
rend
Compatible with Flat&Pitched Roofs s� Corrosion "-Resistant Materials
XR Rails"O are % IronRidgOl offers All XR Rails19 are made of 6000-series ,
compatible with t ♦ a range of tilt leg aluminum alloy,then protected with an
FlashFootO and options for flat anodized finish.Anodizing prevents surface
other pitched roof roof mounting and structural corrosion,while also providing
attachments. applications. a more attractive appearance.
XR Rail° Family
The XR Rail°Family offers the strength of a curved rail in three targeted sizes. Each size supports specific
design loads, while minimizing material costs. Depending on your location, there is an XR Rail®to match.
XR10 XR100 XR1000
XR10 is a sleek,low-profile mounting XR100 is a residential and commercial XR1000 is a heavyweight among
rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails. It's built to handle
no snow. It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12
while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications.
6'spanning capability 10'spanning capability 12'spanning capability
Moderate load capability Heavy load capability Extreme load capability
Clear&black anodized finish Clear&black anodized finish Clear anodized finish
Internal splices available Internal splices available Internal splices available
Rail Selection
The table below was prepared in compliance with applicable engineering codes and standards.* Values are
based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof
Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters.
Rail Span
• ifiiiiiii r
E -t
90 '
120 �,._ ,,.�..1 � ,,,.. � , � � .,� .. ..
None
140 XR10 XR100 XR1000 "
160
90
120
20
140
160
90
30
160
90 x%
40 160 s
80 160
_..._
120 160
s
� y
ti
Tab:e is i n.:ant is 5...a for conveying ge jal rad c ;pabili c> tJ.,c«lip o..-d cer ifir atior .c.t...for actw.tl cpesign guidawu e
IRONRIDGE XR1009 Rail
See Description / Length
Rail Section Properties
Property Value
Total Cross-Sectional Area 0.582 in
.66 Section Modulus (X-axis) 0.297 in'
.46 Moment of Inertia (X-axis) 0.390 in'
- -- — Moment of Inertia (Y-axis) 0.085 in4
Torsional Constant 0.214 in3
Polar Moment of Inertia 0.126 in4
1.99 APPROVED MATERIALS:
;?,4.. 6005-T6, 6005A-T61, 6105-T5, 6N01-T6
2.34 (34,000 PSI YIELD STRENGTH MINIMUM)
.58
! _......... ..j....-.. I
1.25
Clear Part Black Part Description/Length Material Weight
Number Number
XR-100-132A XR-100-132B XR100, Rail 132"(11 Feet) 7.50lbs.
XR-100-168A XR-100-168B XR100, Rail 168"(14 Feet) Alum-Series 9.55 lbs.
XR-100-204A XR-100-204B XR100, Rail 204"(17 Feet) Aluminum 11.60 lbs.
v1.11