Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
52422-Z
OF SOpryo`o Town of Southold P.O. Box 1179 �M' 53095 Main Rd 00 Kn. {� Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46965 Date: 04/10/2026 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 270 Harvest Ln Mattituck, NY 11952 Sec/Block/Lot: 120.-3-8.15 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 10/14/2025 Pursuant to which Building Permit No. 52422 and dated: 10/31/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof mounted solar to existing single family dwelling as applied for. The certificate is issued to: North Fork Landholdings LLC Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 2025-1166261 3/30/2026 PLUMBERS CERTIFICATION: A6toriUe Signature �"nVsn", TOWN OF, SOUTHOLD BUILDING DEPARTMENT • SOUTHOLD, NY Coorm."``�i BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52422 Date: 10/31/2025 Permission is hereby granted to: North Fork Landholdings LLC 400 Eagles Nest Ct Laurel, NY 11948 To: Install roof mount solar to existing single family dwelling as applied for. Disconnects must be located on the exterior, labeled, and readily accessible. Premises Located at: 270 Harvest Ln, Mattituck, NY 11952 SCTM# 120.-3-8.15 Pursuant to application dated 10/14/2025 and approved by the Building Inspector. To expire on 10/31/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 CO-RESIDENTIAL $100.00 Total $200.00 Buil ing Inspector :., Electrical Ins ectors, Inc. 2025-1166261 Southold,Town Of / Fy Inspector: 115 "t.:, Issue Date: 12/19/2025 ` ' New York Board of Fire Underwriters 300 East Meadow Avenue y East Meadow,NY 11554 yr Office:(516)794-0400(631)650-0200 Website:www.eiiny.com Mail To: Property Address: ^;n \ Catizone Electrical Contracting,Inc. Patrick Fedun .. Michael J.Catizone 270 Harvest Lane _ 2060 Ocean Avenue Mattituck NY 11952 r:r Ronkonkoma NY 11779 License# Michael J.Catizone 36178ME ELECTRICAL APPROVAL CERTIFICATE ' { = '. Section: Block: Lot: Permit:52422 l% AREAS LISTED BELOW ARE APPROVED BY Inspection <\ AND FOUND TO BE IN COMPLIANCE WITH THE BUILDING CODE OF NYS AND CURRENT PROMULGATED NEC ;r No visual defects were found for the electrical inspection provided.No obvious unsatisfactory conditions " . / were found in the areas herein below only. ., Residential Inspection Final Approved 12/17/2025st y► \� Solar.Total System Size 13.2 KW DC— 30 Hyundai.440 Solar Panels&30 En phase Inverters.' Y Y P ♦ 4 1 r. This electrical inspection and certificate does not take into account any FEMA,NYS and local flood ' . - :�.. j elevation requirements.It is the responsibility of the property owner to determine if flood elevation =a requirements apply. NYBFU and Ell are not responsible for any Flood Elevation requirements. Therefore this electrical certificate is only for compliance of NYS Electrical and NEC Codes. Ste' j ft ■ �7►°� , s Richard M.Bivone Philip Goehring Jr. t�' President Chief Electrical Inspector r; This document features a tamper proof Quick Response code which contains the encrypted original data submitted when certificate was issued. "78; � � aY.�x '��—J'fr � .�.uy� �\\•y,l.u' rI/� \?'�• b�`/�/ �� �' L� \\��.:.. , L/� V A'Y�..N./ tiai;�l,•!e!.. <<r elf 0,, .. � Ni,1':}@i� °rl,:�;1 �,� •tarl CNi�id •t I'. �y.��� •�: �y'' `i:4►0 �:'' ➢. ELECTRICAL INSPECTORS, INC.is not responsible for the existing conditions located at the subject premises. 2.ELEMIOCA1,Il(lSlC't�' ; ZS, INC.is not responsible for corrections, upgrading`or replacement of existing electn�al violatsons'at#� t ' ij�remises. Any corrective work shall be solely the responsibility of the property ,_, owner. ELECT'RICAE`I P ''TORS,INC. DOES NOT WARRANTY OR UNDERWRITE THE ELFU- Af4Cf+I IQJIJ TTHE PREMISES. 3. ELECTRICAL INSPECTORS, INC.only recognizes the National Electric Code, the Building Codes of New York State all volumes and Local Municipal Codes, as Authorized by The Department of State Codes Division,via Village,Town or City Board Resolution. 4. AN ELECTRICAL SURVEY consists of a visual examination of the premises ONLY: Electrical Inspectors Inc. will comply with the requirements of NFPA 73, latest edition Chapter 1, Section 1-1, 1-2. If violations exist, a Notice of Violation(NOV)will be issued requiring corrections by a licensed electrical contractor. After the violation has been corrected, a re-inspection will be conducted and if approved a certificate shall be issued. 5. AN ELECTRICAL CLOSED WALL INSPECTION consists of a visual examination of the area requested ONLY: Electrical Inspectors Inc, will comply with the requirements of NFPA 73, latest edition Chapter 1, Section 1-1, 1-2. I f violations exist,a Notice of Violation(NOV)will be issued requiring corrections by a licensed electrical contractor. After the violation has been corrected,a re-inspection will be conducted and if approved a certificate shall be issued. 6. A SURVEY CERTIFICATE does not examine the actual wiring or devices unless all walls are opened and wires and devices are exposed prior to the survey being conducted. 7. A CERTIFICATE is non-transferable. 8. AN ELECTRICAL INSPECTION consists of an examination of wiring and installations during the rough stages ol'construction. After completion of the construction a final inspection will be conducted at which time a certificate will be issued provided no violation exists. In the event an inspection is not requested during the rough stages of construction ELECTRICAL INSPECTORS,INC. will perform a CLOSED WALL SURVEY that consists of a visual inspection of the wiring and installations only. Since access is limited, ELECTRICAL INSPECTORS, INC.shall bear no responsibility for any defects or violations at the premises. 9. ELECTRICAL INSPECTORS, INC.shall not be responsible to remove any walls in order to conduct an electrical inspection. 10. ELECTRICAL INSPECTORS, INC.will only release information,certificates and reports to the applicant after payment for services rendered have been paid in full. 11. ELECTRICAL INSPECTORS, INC.assumes no liability for the results of its inspections. 12. The agreement may not be changed orally. 13.The New York [bard of Fire Underwriters, Inc.,is a subsidiary of Electrical Inspectors, Inc. It is fully operational and functional and perlonns electrical inspections as it always has. 14.The New York Board of'Fire Underwriters,Inc. and Electrical Inspectors, Inc. inspects properties for compliance with the Building Code of the State of New York, counties and local electrical codes, as well as the promulgated NEC (National Electrical Code). oF souryO6 # # TOWN OF SOUTHOLD .BUILDING DEPT. co 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ]. FOUNDATION 2ND [ ] INS LATIOWCAULKING [ ] FRAMING /STRAPPING [ .FINAL .50 4,e- [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 0�_ DATE "a2 - INSPECTOR 1t Michael E. Miele, PE Licensed Professional Engineer Licensed In New York, New Jersey, Connecticut& California New York License#079676 New Jersey License#44042 Connecticut License#23158 California License#31508 December 29, 2025 Town of Southold Building Department The Office of the Building Inspector 54375 NY-25 Southold, NY 11971 Re: Patrick Fedun—270 Harvest Lane, Mattituck, NY 11948 Single Family Residence, Solar Panel Installation Certification Town of Southold, County of Suffolk, State of New York Dear Building Department, have reviewed the solar energy system installation at the subject address. The system has been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets all building code requirements and is certified as for all code and approved plans for the Town of Southold. I completed my final inspection on December 20, 2025 and I can hereby certify that the installation complies with the 2020 New York State Residential Building Code and all applicable codes and design loads as referenced on the approved plans, including ASCE 7-16 (Minimum Design Loads and Associated Criteria for Buildings and Other Structures). If you have any questions, please feel free to call me at any time.Thanks, in advance. Sincerely Yours, i/ —__N E y P V E Wq O� rn LU oc Michael E. Miele, PE ��;0 079676 �A P ESS10 705 Orrs Mills Road, New Windsor, NY 12553 ♦ Phone 845.629.9693 ♦ NYPSengineer@gmail.com FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) ------------------------------------ C FOUNDATION (2ND) [� � o G ROUGH FRAMING& 1 PLUMBING v \ INSULATION PER N.Y. STATE ENERGY CODE liC. O. FINAL ADDITIONAL COMMENTS $ � zS m s � 0 o � k c� J p z x d b o7§ TOWN OF SOUTHOLD—BUILDING DEPARTMENT d W �� Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtowM.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only 0, PERMIT NO. a' Building Inspector: t Application aod,forms must be filled out in.their;enti[ety Incomplete c� ` i t.f applications will not be accepted:'Where the Applicankis not the owner,an' Owners-Authorization form(Page 2)shall be completed Date: a OWNER S).OF PROPERTY, Name: ` SCTM#1000- Physical Address: Phone# 3.�.. w P....I q._ Email: n�. Mailing Address: _ . 9_u CONTACT PERSON: .. -Name permit Dept./Long Island Power Solutions Mailing Address:2060 Ocean Me., Ronkonkoma NY 11779 Phone# Email_ ._._.._.,@..,,. � -...., l „ - _. com 631 348-0001 rn„q� _p _ _ e_ rt R _ry _ Permits o owes o utlons. , DESIGN PROFESSIONAL_INFORMATION Name: Mailing Address: Phone# Email CONTRACTOR INFORMATION: Name Michael Catizone/Long Island Power"Solutions rnm a r Mailing Address:2060 Ocean Ave., Ronkonkoma, NY 11779 Phone#:63Y1 -348 0001 T 9Sµ - Email_Mike,@.PqPowerSolutions.com DESCRIPTION OF:PROPOSED CONSTRUCTION ❑New Structure ❑Addition BAlteration ❑Repair ❑Demolition Estimated Cost of Project: B Other Proposed(3p)panel roof mounted array. (1 &2JD)kW System $ Will the lot be re-graded? ❑Yes iiNo Will excess fill be removed from premises? ❑Yes ®No _ 1 ' PROPERTY INFORMATION Existing use of property Sin le Fami1v Dwelling Intended use of property:Sin le Fami.l Dwellin Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? []Yes BNo IF YES, PROVIDE A COPY. B Check.Box A fter,Reading:,, The owner/contractor/design professional is responsible for all drainage and storm water.issues as Provided by Chapter 236 of the Town Code. APPLICAT,ION,IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone;. ordinance of the Townyof Southold,Suffolk,County,New York and,othei a0plici6ler Laws,Ordinances or Regulations for the construction of bwldings, additions,alterations or,for removal or demolition as herein described.The applicant agrees to comply+with all applicable laws,,ordinances,building'code, housing code"and regulations and to admit a.uthonied inspectors on premises'and in buildmg(s)for'necessary inspectionsc False statements made herein are punishable as Class A,misdemeanor pursuant to Secfion 210.4S of the New York Sfate Penal law. CatiWE0,'ecctn'ca,1,/Lg Island Power Solutions Application Submitted By( BAuthorized Agent ❑Owner Signature of Applicant:-,,,-,,,, Date. STATE OF NEW YORK) SS: COUNTY OF-Suffolk ) Michael Catizone being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and"to make and-file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of ,�--�hQ�' ,20,,—S Ctl. Notary'Public ESCAYLIN CRISOL RIVERA R0DRIGU!7.? PROPERTY OWNER AUTHORIZATION NOTARY PUBLIC-STATE OF NEW YG'ri (Where the applicant is not the owner) No. 01 R 16434031 Qualified in Suffolk County My Commission Expires 05-31-2026 Ju i1 residing at a-Zb 4a. W5+ L A-C Michael Catizone/Long Island Power Solutions t('f do hereby authorize to apply on my al to a Town of Southold Building Department for approval as described herein. Owner's Signature Date n ( .� Print Owner's Name 2 LONG 'IBLAND OWER2060 Ocean Ave Ronkonkoma, NY 11779 (-01� P,SCOLUTIONS 631 348-0001 www.longislandpowersolutions.com OWNER AUTHORIZATION This affidavit certifies that Long Island Power Solutions has been granted permission to sign for and obtain permit(s)on behalf of the property owner(s). I, Ec u n ,Owner of the property located at: Street Town Atate Zip Tax Map ID#: I CX�)Q- i2-0- - FS.\�. Do hereby give: Long Island Power Solutions permission to sign all applications and to have the permit(s) sent directly to: Long Island Power Solutions 2060 Ocean Avenue Ronkonkoma,NY 11779 Attu:Permit Dept. Pa)r�u (Pro erty wner) Print Name (Property Owner) Signature Sworn To Before Me This 2-1 Day O Margaret A Barker `? (NOTARY PUBLICSIGNATURE) Notary Public State of New York No'OIBA0000779 S oualified in Suffolk County 2027 I' Commission Exp ire.February �{ li Notary Stamp Go Green Save Green F17� `r BUILDING DEPARTMENT- Electrical Inspector ;., TOWN OF SOUTHOLD � t Town Hall Annex - 54375 Main Road - PO Box 1179 r' Southold; New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 .:- rogerr _southoldtownngov -_seand(a southoldtownny.aov APPLfCA]ON FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: aS. Company Name: Catizone Electrical/Long Island Power Solutions Name: Michael Catizone License No.: email: Permits@GoPowerSolutions.com Address: 2060 Ocean Avenue,Ronkonkoma,NY 11779 Phone No.: 631-348-0001 JOB SITE INFORMATION (All Information Required) Name: Address: _ - - oZ-76 _ e � _ fl°IN _ Cross Street: Phone No.: -_��1 - � I - -i- 1 Bldg.Permit email: n3-,,j<ff �I Tax Map District:. 100.0 Section: I�.p, Block:._ _-_ Lot., , \� BRIEF DESCRIPTION OF WORK (Please Print Clearly) Proposed(ac))panel roof mounted array. ( 13.�20)kW System -'i OL-H- s Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On empinformation: (All information required) Service Size 1 Ph 3 Ph Size: . A #Meters Old Meter# . . New Service- Fire Reconnect- Flood Reconnect- Service Reconnected- Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additionallnformation 6-6 PAYMENT DUE-WITH-APPLICATION Request for Inspection FormAs LONG ISLAND Ow' ' E R 2060 Ocean Ave Ronkonkoma, NY 11779 SOLUTIONS 631 348-0001 www.longislandpowersolutions.com TOWN OF SOUTHOLD—Building Division Town Hall Annex Building 54375 Route 25 P.O. Box 1179 Southold,NY 11971 Dear Building Dept: As per your Building Department, enclosed please find the building permit application, submitted on behalf of our client/property owner: Property Owner: Patrick Fedun-917-359-0825 Project/Property Address: 270 Harvest Lane, Mattituck NY 11952 Section/Block/Lot: 120.-3-8.15 Electrician Michael Catizone—2060 Ocean Ave.,Ronkonkoma,NY 11779—(631)348-0001 Contractor LI Power Solutions—2060 Ocean Ave.,Ronkonkoma,NY 11779—(631)348-0001 Architecture&Planning: Michael E.Miele-PE-33 Quaker Avenue,Po Box 530, Cornwall NY 12518- 845-629- 9693 Enclosed Please find: • Application Fee: $200.00 • Permit Application • (4) Copies of the Property Survey • (4) Copies of the Engineering Drawings & Specs • Liability, Disability & Workman's Comp Insurance Certs Please send the Receipt and Permit to Long Island Power Solutions. Should you require anything further, please contact me. Sincerely, Escaylin Rivera Permit Manager Long Island Power Solutions 2060 Ocean Avenue Ronkonkoma,NY 11779 Ph- 631-348-0001 Fx- 631-348-0018 Pennits@gopowerosolutions.com Go Green Save Green SURVEY OFPROPERTY LOT 13 MAP OF FARMVEU ASSOCIATES FILED: SEP. 0>, 1989 — MAP #:8808 SCTM. 1000-120.00-03.00-008.015 SITUATE 270 HARVEST LN, MATTITUCK, NY, 11952 MATTITUCK TOWN OF SOUTHOLD SUFFOLK COUNTY, N.Y. LOT AREA SURVEYED JUNE 15 2022 40000.00 S.F. UPDATED: DEC. 05, 2024 (0.918 ACRE(S)) LOT 17 N/F KERRI SPIELER &MICHAEL SPIELER LOT 1e N70019'30"E 4'CHAIN LINK FENEE z O.B S .00 FE 4'IN W 0.4'W w C 3 w ¢ O O i 'd O W O F co S SHED j F X WILL 10,X16 FRAME SHED 49.0 F 12 A s2 � y = ECK 2TOR.6� " ,se• e q FE 0 41Y 66.2 .cii v 1 Story Flame Res&7we 'n OSE: Z - C7 #270 O GWAGE (a O 24.0' n V 16 O R OKAi O C1' r' ev o • CERTIFIED TO: �/] 3 EMINENT ABSTRACT, INC c WESTCOR LAND TITLE INSURANCE COMPANY NORTH FORK LANDHOLDINGS, LLC 163.00' � S70019'30"W 125.00 HARVEST LANE(so') i z STANDARD NOTES: I.CaPmlcnr ED RCwEL IL WwNs I.M.THIS STI 2.UN ED UVID S ALTEOWS OR A A VIC TO THIS SURVEY WP—NO A COPIES OF THIS SURVEY MAP NOT BEARNG THE TO SURVEYOR'S INKED LN'ENSED 4ND SU HE RC'.Fil.R A vpuTaN or SECTION Y209. OR EMBOSSED SEAL SHALL NOT RECONSIDERED TO BE A VALID COPY. sue-oNmoR z of HER wRH spTc mucTrwN uW. 0.ONLY e0UNINRY SURVEY NAPS WDH THE SUR&WR'S EMBOSSED SPAL OF NEW),ME GENUINE TRUE MO CORRECT COPIES OF ME SURVEYOR'S ORIdNA1 MICHAEL K. WICKS AOcwnrw PINIiroNs aN TNR BouNweY suaVEY uAP StcwFY TW.r TI¢MAP ��P G�PF K.K,'c�iQ� MED OF IM ECURREHE ��nn OR �` �s LAND SURVEYING AO50CNT°N OF MCFESSONX LMO SURVEYORS.INC.THE CTATIRWON IS UWTE0 TO PERSONS FOR—THE WEUMCMY SURVEY IUP R PREPARED. * * 15 FROWEIN ROAD— SUITE E2 y_TO THE TRLE COMPANY.TU THE GOvERNUENfu AGENCY.AND TO THE FENDING INSTITUTION USTED ON THIS BOUNOMY SURVEY W. CENTER MORTCHES, NEW YORK 11934 5.THE CERFMCMOAS HERON ARE NOT iRAnSFTHINLE. VOICE.' S31.974.01$5 ~ 0.TIE L..—OF UNDCROROUNO WPRtlYp1ENR OR OiCROACHMENTS ME w NOT ALWAYS NNOWN.0 OFTEN RUST BE EBTROTED. IF MY UNDERGROUND � Q wuw.7U'LCTDSLa'R.dSi-eyiCng.00m IYFR�E°MD5 M o Cev ENTS ME NOT WIER SHORN 0 COST OR ME Tb5 SUx . F NO.050390 i� RECORDS OF RICHARD C. DRAKE 1c; T.THE OWTSE(OR DIMEM""'sRD«N HEREDn FROM THE SWUCTURES TO y'sFQ SVR�� SCALE: SURVEYED Ei'(: DRAWN BY: SHEET:THE PROPERTY UTES ME FORA SPEdFIC PURPOSE MD USE MD THEREFORE �AND ME NOT RRENOED TO COX ME ERECNON W FENCES.RETAINING WALLS. 1 =4O M.W. 1 OF Pori,vAnos M"EIRO Mc s.ADOWNs TO SU-N s,um urc EM. A{ICHAEL K WICKS. P.LS. #50390 �'W'W'TYPc a CaNDR—. , Michael E. Miele, PE �� - Licensed Professional Engineer Licensed In New York, New Jersey, Connecticut&California New York License#079676 New Jersey License#44042 Connecticut License#23158 California License#31508 September 29, 2025 Town of Southold Building Department The Office of the Building Inspector 54375 NY-25 Southold, NY 11971 Re: Patrick Fedun—270 Harvest Lane, Mattituck, NY 11952 Single Family Residence,Solar Panel Loading Certification Town of Southold, County of Suffolk,State of New York Dear Building Department I am the engineer of record for the above referenced project. I have prepared the attached plans dated September 25,2025 that consist of the installation of(30) HIS-T440NF(BK)solar panels at the above referenced location. I can hereby certify that the existing roof structure combined with the additional weight of the solar panels meets the requirements of The 2020 Residential Code of New York State, Publication Date, November 2019. The design loads were as follows, Ground Snow Load: 20psf Wind Design Load: 134mph No additional structural members were required. The roof is currently framed with 2x8 wood framing @ 16"O.C.The roof structural members are in compliance with ASCE 7-16 for deflection and acceptable bending stress. If you have any questions, please feel free to call me at any time.Thanks in advance. if NEW i, Sincerely Yours, A ��Q'G L E. �/ p� Z Michael E. Miele, PE ti 079676 pROFESSIQ���, 705 Orrs Mills Road, New Windsor, NY 12553 ♦ Phone:845.629.9693♦ NYPSengineer@gmail.com PAT R I C K F E D U N CONTRACTOR OWER SOLUTIONS AHJ UTILITY SCOPE OF WORK VICINITY MAP LONG ISLAND POWER TOWN OF SOUTHOLD LONG ISLAND POWER (N) 13.20KW DC ROOF MOUNTED PV SYSTEM AUTHORITY (30) HYUNDAI SOLAR HIS-T440NF(BK) MODULES ^` `-T SOLUTIONS (30) ENPHASE IQ8MC-72-M-US MICROINVERTERS l so _ 2060 OCEAN AVENUE, (01) ENPHASE IQ COMBINER 4/4C PANEL Und:Ave ,•'��,, RONKONKOMA, NY 11779, CODES AND STANDARDS WITH AMENDMENTS °`,� �,��a '. ' _ 631-348-0001 2020 BCNYS 2020 FCNYS 2020 RCNYS OCCUPANCY ®P Construction Inc tYJ 2017 NEC /�,/�/ 270 HarvestCn, PROJECT INFO&ADDRESS USE IS UNLAWFUL PATRICK FEDUN ' Mattituc NY 11952, United States •{� WITHOUT CERTIFICATE � � 270 HARVEST LN, DETAIN STORM WATER RUNOFF .�-°' ENVIRONMENTAL ' ,.�aNes� MATTITUCK, WIND SPEED: 134 MPH PURSUANT TO CHAPTER 236 OF OCCUPANCY NY 11952 SNOW LOAD: 20 PSF OF THE TOWN CODE. EXPOSURE CATEGORY: B SYSTEM SIZE DC SIZE: 13.200 KW DC-(STC) GENERAL NOTES -TO THE BEST OF MY KNOWLEDGE, APPROVED AS NOTED BELIEF AND PROFESSIONAL JUDGMENT,THE PLANS AND PROJECT NOTES: SHEET INDEX SPECIFICATIONS ARE IN -THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH DATE• O' �� g.p# COMPLIANCE WITH THE 2020 THE NATIONAL ELECTRIC CODE (NEC)ARTICLE 690,ALL PV_1 COVER SHEET RESIDENTIAL CODE OF NEW YORK MANUFACTURER'S LISTING AND INSTALLATION FEE STATE. �'�BY: PV-2 SITE PLAN-1 -IT IS A VIOLATION OF THE LAW FOR INSTRUCTIONS,AND THE RELEVANT CODES AS SPECIFIED NOTIFY BUILDING DEPARTMENTAT PV-2.1 SITE PLAN-2 ANY PERSON,UNLESS ACTING BY THE AUTHORITY HAVING JURISDICTION'S AHJ ATTACHMENT PLAN UNDER THE DIRECTION OF A (AHJ) 631-765-1802 8AM TO 4PM FOR THE PV-3 LICENSED PROFESSIONAL,TO APPLICABLE CODES. FOLLOWING INSPECTIONS: PV-3.1 STRUCTURAL PLAN ALTER AN ITEM IN ANY WAY.IF AN -THE UTILITY INTERCONNECTION APPLICATION MUST BE 1. FOUNDATION-TWO REQUIRED PV-4 ELECTRICAL ITEM BEARING THE SEAL OF A APPROVED AND PV SYSTEM INSPECTED PRIOR TO -� PV-4.1 ELECTRICAL CALCULATIONS LICENSED PROFESSIONAL IS FOR POURED ELECT CONCRETE ALTERED,THE ALTERING LICENSED PARALLEL OPERATION 2. ROUGH-FRAMING&PLUMBING PV-5 LABELS PROFESSIONAL SHALL AFFIX TO -GROUND FAULT DETECTION AND INTERRUPTION (GFDI) 3. INSULATION PV-6 RESOURCE DOCUMENT THEIR ITEM THEIR SEAL AND THE DEVICE IS INTEGRATED WITH THE MICRO INVERTERS IN NOTATION"ALTERED BY" 4. FINAL-CONSTRUCTION MUST PV-6.1 RESOURCE DOCUMENT FOLLOWED BY THEIR SIGNATURE ACCORDANCE WITH NEC 690.41(B) BE COMPLETE FOR C.O. PV-6.2 RESOURCE DOCUMENT AND THE DATE OF SUCH -ALL PV SYSTEM COMPONENTS; MODULES, UTILITY- ALTERATION,AND A SPECIFIC INTERACTIVE INVERTERS,AND SOURCE CIRCUIT COMBINER ALL CONSTRUCTION SHALL MEET THE PV-6.3 RESOURCE DOCUMENT REQUIREMENTS OF DESCRIPTI TION. THE PV-6.4 RESOURCE DOCUMENT BOXES ARE IDENTIFIED AND LISTED FOR USE IN PV-6.5 RESOURCE DOCUMENT Q, PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4: PV YORK STATE. NOT RESPONSIBLE FOR l L E. MODULES: UL1703, IEC61730,AND IEC61215,AND NFPA 70 DESIGN OR CONSTRUCTION ERRORS PV-6.6 RESOURCE DOCUMENT PV-6.7 RESOURCE DOCUMENT fr CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, PV-6.8 RESOURCE DOCUMENT 929, 519 COMBINER BOX(ES): UL 1703 OR UL 1741 PV-6.9 RESOURCE DOCUMENT ACCESSORY comply WITH ALL CODES OF -MAX DC VOLTAGE CALCULATED USING MANUFACTURER NEW YOR STATE& TOWN CODES Q 079676 PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, AS REQD ED AND CONDITIONS OF MAX DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7. -ALL INVERTERS, PHOTOVOLTAIC MODULES,PHOTOVOLTAIC SOUTHOLD TOWN ZBA DRAWN BY BA PANELS,AND SOURCE CIRCUIT COMBINERS INTENDED FOR SOUTHOLD TOWN PLANNING BOARD USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE SOUTHOLD TOWN TRUSTEES DATE 9/25/2025 IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4.SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS N.YS.DEC REVISION FROM LISTING OR LABELING [NEC 110.31. SOUTHOLD HPC SIGNATURE -ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL SCHD BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV PV-1 RESISTANT.ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. COVER SHEET SCOPE OF WORK CONTRACTOR (N) 13.20KW DC ROOF MOUNTED PV SYSTEM TOTAL ROOF SQUARE FOOTAGE IS:2965.04 FTZ (30) HYUNDAI SOLAR HIS-T440NF(BK) MODULES NEW ARRAY SQUARE FOOTAGE IS: 630.58 FTZ @WER (30) ENPHASE IQ8MC-72-M-US MICROINVERTERS COVERED BY SOLAR IS: 21.27% SOLUTIONS (01) ENPHASE IQ COMBINER 4/4C PANEL LONG ISLAND POWER SOLUTIONS 2060 OCEAN AVENUE, RONKONKOMA, NY 11779, 631-348-0001 PROJECT INFO&ADDRESS NC / \` PATRICK FEDUN '\ 270 HARVEST LN, MATTITUCK, \, NY 11952 SYSTEM SIZE `\ DC SIZE: 13.200 KW DC-(STC) -TO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGMENT,THE PLANS AND SPECIFICATIONS ARE IN \ COMPLIANCE WITH THE 2020 \ RESIDENTIAL CODE OF NEW YORK STATE. -IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS\ \ Into UNDER T ACTING HE DIRECTION OF A LICENSED PROFESSIONAL,TO U? \ ` ALTER AN ITEM IN ANY WAY.IF AN J ITEM BEARING THE SEAL OF A \ LICENSED PROFESSIONAL IS ALTERED,THE ALTERING LICENSED PROFESSIONAL SHALL AFFIX TO THEIR ITEM THEIR SEAL AND THE NOTATION"ALTERED BY" FOLLOWED BY THEIR SIGNATURE %% AND THE DATE OF SUCH �jG \ ALTERATION,AND A SPECIFIC DESCRIPTIO ERATION. 16 FJ Tz- / P� E y® v �GLLJ LEGEND P.� v ®FIRE PATHWAYS �A 079676 -PROPERTY LINE DRAWN B -0 FENCE ® SKYLIGHT/CHIMNEY DATE 9/25/2025 O ❑ VENT/OBSTRUCTION REVISION SIGNATURE SITE PLANA PV-2 SCALE:1/6411=1'-0" SITE PLANA SCOPE OF WORK CONTRACTOR (N) 13.20KW DC ROOF MOUNTED PV SYSTEM TOTAL ROOF SQUARE FOOTAGE IS: 2965.04 FTZ O�G� (30) HYUNDAI SOLAR HIS-T440NF(BK)MODULES NEW ARRAY SQUARE FOOTAGE IS: 630.58 FT2 SOLUTIONS (30) ENPHASE IQ8MC-72-M-US MICROINVERTERS COVERED BY SOLAR IS: 21.27% (01) ENPHASE IQ COMBINER 4/4C PANEL LONG ISLAND POWER SOLUTIONS 2060 OCEAN AVENUE, RONKONKOMA, NY 11779, 631-348-0001 Lip PROJECT INFO&ADDRESS (N)(30)HYUNDAI SOLAR HIS-T440NF(BK)MODULES . � PATRICK FEDUN WITH ENPHASE IQ8MC-72-M-US MICROINVERTERS ST LN, R HAVE UNDER EACH MODULE(240V) 27 270 0 HARVEST NY 11962 LADDER ACCESS-2 SYSTEM SIZE DC SIZE: 13.200 KW DC-(STC) 31-011 -TO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGMENT,THE PLANS AND O SPECIFICATIONS ARE IN COMPLIANCE WITH THE 2020 RESIDENTIAL CODE OF NEW YORK STATE. -IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL,TO ALTER AN ITEM IN ANY WAY.IF AN O ITEM BEARING THE SEAL OF A (N)CONDUIT RUN LICENSED PROFESSIONAL IS r ALTERED,THE ALTERING LICENSED PROFESSIONAL SHALL AFFIX TO THEIR ITEM THEIR SEAL AND THE ' NOTATION"ALTERED BY" tom` FOLLOWED BY THEIR SIGNATURE `v AND THE DATE OF SUCH (N)ENPHASE IQ COMBINER 4/4C LADDER ACCESS-1 ALTERATION,AND SPECIFIC 00 co DESCRIPTIO TION. WITH ENPHASE IQ GATEWAY (OUTSIDE HOUSE) ry (N)VISIBLE LOCKABLE LABELED co E. yO� a AND FUSED AC DISCONNECT ` or (UTILITY DISCONNECT) (OUTSIDE HOUSE) / LEGEND cl ®FIRE PATHWAYS ip-71 (N)JUNCTION BOX QA 079676 O �( NEMA 4X RATED PROPERTY LINE G� SQ DRAWN BY 0 FENCE ® SKYLIGHT/CHIMNEY DATE 9/25/2025 (E)MANUAL TRANSFER SWITCH REVISION O ❑ VENT/OBSTRUCTION (INSIDE BASEMENT) (E)MAIN SERVICE PANEL SIGNATURE SITE PLAN-2 (INSIDE BASEMENT) PV-2.1 (E)UTILITY METER SCALE:1/8"=1'41 (UNDERGROUND SERVICE) (OUTSIDE HOUSE) SITE PLAN-2 ROOF SECTION(S) CONTRACTOR o ROOF MATERIAL- 2116 7'_ �- COMPOSITE SHINGLE 11'_ " 6" TIOWERLUTIONSSO ROOF 1 RAFTER SIZE-2"X8" O.C.SPACING-16" MODULES-2 I I I I I I I I I I I I I l l l l l ROOF MATERIAL- I I I I I I I COMPOSITE SHINGLE I j j I I I I - LONG ISLAND POWER ROOF 2 RAFTER SIZE-2"x8" I I I I I I I O.C.SPACING-16" I I I I °p SOLUTIONS MODULES-26 2060 OCEAN AVENUE, ROOF MATERIAL- RONKONKOMA, NY 11 779, COMPOSITE SHINGLE 631-348-0001ROOF 3 RAFTER SIZE-2"X8" ARRAY 1 O.C,SPACING-16" TILT- 37 DE MoouLEs-z AZIMUTH 239 DEG PROJECT INFO&ADDRESS 611 PATRICK FEDUN 411 270 HARVEST LN, N 7'-611 8'-9" 34'-1" 9'-7" T-6" MATTITUCK, NY 11952 IL I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I I l I l l i iy1o"911 i i i I I SYSTEM SIZE I I I I I I I 1 1 1 1 I I I I I I I I I I I I I I 1 1 1 I I I I DC SIZE: 13.200 KW DC-(STC) �' IIIIIIIIIrio I I I I I I I I I I I I I I I I I I -TO THE BEST OF MY KNOWLEDGE, IBELIEF AND PROFESSIONAL I I I I I I I I I I I I I I I I I I I I I I I I JUDGMENT,THE PLANS AND SPECIFICATIONS ARE IN I I I I I I I I I COMPLIANCE WITH THE 2020 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I RESIDENTIAL CODE OF NEW YORK I I I I I I l l l l l l l l l l l l l l l I I I I I I I I STATE. I I I ARRAY 2 -IT IS A VIOLATION OF THE LAW FOR 1 I i l ANY PERSON,UNLESS ACTING TILT- 26 DEG UNDER THE DIRECTION OFA I I I I I I I I I I I I I I I I I I I I I I LICENSED PROFESSIONAL,TO I I I I I I I I I I I I I I I I I I I I I I AZIMUTH - 149 DEG ALTER AN ITEM IN ANY WAY.IF AN I I I I I I I I I I I I I I I 1 1 I I I I I I I I I I I I I I ITEM BEARING THE SEAL OF A I LICENSED PROFESSIONAL IS I I I ALTERED,THE ALTERING LICENSED PROFESSIONAL SHALL AFFIX TO THEIR ITEM THEIR SEAL AND THE NOTATION"ALTERED BY" FOLLOWED BY THEIR SIGNATURE AND THE DATE OF SUCH ALTERATION,AND A SPECIFIC DESCRIPT TION. DEAD LOAD CALCULATION BOM QUANTITY LBS/UNIT TOTAL C, L E. 0,4 - -- 9'-5" 7'-6" 3" WEIGHT(LBS) 0 -CLAMP HYUNDAI SOLAR 30 53.57 1607.10 HIS-T440NF(BK) MODULES • - IRONRIDGE QUICKMOUNT HUG 1 1 I 1 MID-CLAMP 42 0.15 6.30 1 I I I I I I I I _ b0 END-CLAMP 36 0.15 5.40 079676 - I IRONRIDGE AIRE RAIL Al I `-) RAIL LENGTH 24 6.36 152.64 A� c Ip� SPLICE BAR 6 0.525 321.42 01, --------- - RAFTER I i I i i IRONRIDGE QUICKMOUNT 75 0.57 42.75 DRAWN BY BA HUG DATE 9/25/2025 I 75 -TOTAL MOUNT ' i ENPHASE IQ8MC-72-M-US 30 2.43 72.90 REVISION ARRAY 3 MICROINVERTER TILT- 37 DEG TOTAL WEIGHT OF THE SYSTEM (LBS) 2208.51 SIGNATURE 1 ATTACHMENT PLAN AZIMUTH - 239 DEG TOTAL ARRAY AREA ON THE ROOF (SQ.FT) 630.58 PV-3 WEIGHT PER SQ.FT. (LBS) 3.5023 SCALE:1/8"=V-0" WEIGHT PER PENETRATION (LBS) 29.4468 ATTACHMENT PLAN CONTRACTOR COWER SOLUTIONS LONG ISLAND POWER SOLUTIONS 2060 OCEAN AVENUE, RONKONKOMA, NY 11779, 631-348-0001 MODULE BOTTOM MOUNTING CLIP PROJECT INFO&ADDRESS CLAMP w 4" BOLT PATRICKFEDUN 270 HARVEST LN, AND LOCK WASHER MATTITUCK, NY 11952 HYUNDAI SOLAR HIS-T440NF(BK) SYSTEM SIZE DC SIZE: 13.200 KW DC-(STC) -TO THE BEST OF MY KNOWLEDGE, IRONRIDGE AIRE RAIL Al / / BELIEF AND PROFESSIONAL / JUDGMENT,THE PLANS AND SPECIFICATIONS ARE IN / / / �� COMPLIANCE WITH THE 2020 $ BOLT STATE.RESIDENTIAL CODE OF NEW YORK -IT IS A VIOLATION OF THE LAW FOR (E) COMPOSITE SHINGLE ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL,TO / ALTER AN ITEM IN ANY WAY.IF AN IRONRIDGE QUICKMOUNT HUG ITEM LICENSARINGTHESONALIS LICENSED PROFESSIONAL IS (2) - 5/16" x 3" STAINLESS ALTERED,THE ALTERING LICENSED PROFESSIONAL SHALL AFFIX TO THEIRSTEEL SCREWS , WITH NOTATION ION"ALTTEM IRSEALANDTHE NOTATION"ALTERED BY" FOLLOWED BY THEIR SIGNATURE MINIMUM 2.5" EMBEDMENT AND THE DATE SUCH ALTERATION,ANDD A SPECIFIC DESCRIPTI RATION. If 1_3,. (E) RAFTER 211X8" @ 16" O.C. � 079676 �Z 2 DRAWN BY A DATE 9/25/2025 REVISION SIGNATURE 1 STRUCTURAL PLAN PV-3.1 SCALE:NTS STRUCTURAL PLAN CONTRACTOR SOLAR MODULE SPECIFICATIONS INVERTER SPECIFICATIONS ENPHASE IQ8MC-72-M-US NOTE: QD OWER OTHERWISE NOTED. MANUFACTURER/MODEL# HYUNDAI SOLAR HIS-T440NF(BK)MODULE MANUFACTURER/MODEL# MICROINVERTER - ALL CONDUCTORS ARE COPPER UNLESS SOLUTIONS VMP 32.82V MIN/MAX DC VOLT RATING 22V MIN/58V MAX IMP 13.41A MAX INPUT POWER 460W LONG ISLAND POWER VOC 33.90V NOMINAL AC VOLTAGE RATING 240V/211-264V SOLUTIONS ISC 14.06A MAX AC CURRENT 1.33A 2060 OCEAN AVENUE, TEMP.COEFF.VOC -0.25%/°C MAX MODULES PER STRING 12 (SINGLE PHASE) RONKONKOMA, NY 11779, MODULE DIMENSION 67.8"L x 44.6"W x 1.2"D(In Inch) MAX OUTPUT POWER 320 VA 631-348-0001 PROJECT INFO&ADDRESS PATRICK FEDUN (3)#12 Q CABLES (N) (1)ENPHASE IQ COMBINER 4AC 270 HARVEST LN, (N)(30) HYUNDAI SOLAR HIS-T440NF(BK) WITH ENPHASE IQ GATEWAY TO UTILITY GRID MATTITUCK, MODULES PER MANUFACTURER (3)20A/240VAC CIRCUIT N L1L2N BREAKER 125A RATED ( ) (1)AC DISCONNECT: (E) BI-DIRECTIONAL UTILITY NY 11952 10 MICROINVERTERS IN BRANCH CIRCUIT 1 SPECIFICATIONS, (OUTSIDE HOUSE) VISIBLE, LOCKABLE, LABELED LINE METER 1-PHASE, 3-W, EITHER 60A USED, (2)50A FUSES,240V M 120V/24OV,200A RATED SYSTEM SIZE . 10A OR 15A OR 20A NEMA 3R, UL LISTED (UNDERGROUND SERVICE)..... ... . ffj 4 DC SIZE: 13.200 KW DC- BREAKER IS IQGATEwAv (UTILITY DISCONNECT) LOAD (OUTSIDE HOUSE) (STC) SUITABLE FOR USE �R ESS SUPPLY SIDE TAP T_ J � COMMS L, (OUTSIDE HOUSE) -TO THE BEST OF MY— — — (N)X 6 JUNCTION L2 �2 (E) MANUAL TRANSFER BELIEF AND PROFESSIONAL EDGE, BOX 600V, NEMA 5A/2P N N SWITCH,200A RATED,240V JUDGMENT,THE PLANS AND 4X RATED 2 UNE �—— (INSIDE BASEMANT) SPECIFICATIONS ARE IN 10 MICROINVERTERS IN BRANCH CIRCUIT 2 1 E MTS BREAKER COMPLIANCE WITH THE 2020 1 20Ar2P I 3 1 _ 3 ( ) RESIDENTIAL CODE OF NEW YORK 1 I 1 1 240 V,200A/2P E STATE. 1 I 1 -IT IS A VIOLATION OF THE LAW FOR 1 I 1 ANY PERSON,UNLESS ACTING 1 1 UNDER THE DIRECTION OF A ti J ti J ti 20w2P I I —— —— — L� �o LICENSED PROFESSIONAL,TO 1 LOAD J. i r—— ——— — v (E) MAIN BREAKER ALTER AN ITEM IN ANY WAY.IF AN LINE SIDE TO HOUSE 240 V, ITEM BEARING THE SEAL OF A 1 I I INTERCONNECTION I 20OA/2P LICENSED PROFESSIONAL IS 10 MICROINVERTERS IN BRANCH CIRCUIT 3 I �, 20Al2P I I T ALTERED,THE ALTERING LICENSED 1 Lz —— ——J 1 AT MTS PANEL 1 (E) MAIN SERVICE PANEL, PROFESSIONAL THEIR SEAL AND TO — I PER ART. 705.12(A) I 225A RATED,240V THEIR ITEM THEIR SEAL AND THE c— — — — J L — — NOTATION"ALTERED BY" s� (INSIDE BASEMANT) FOLLOWED BY THEIR SIGNATURE 1 I cec AND THE DATE OF SUCH J— — —— — J EXISTING GROUNDING I N ALTERATION,AND SPECIFIC J_ ELECTRODE SYSTEM TO L _ DESCRIPTI TION. (N) (30) ENPHASE IQ8MC-72-M-US EARTH MICROINVERTERS ONE UNDER EACH REF. NEC 250.52,250.53(A) O,� MODULE(240V) p� 079676 fro PHASE CONDUCTOR CITY,SIZE AND TYPE GROUND CONDUCTOR CITY,SIZE CONDUIT CONDUIT ID PER CONDUIT NEUTRAL CITY,SIZE AND TYPE PER CONDUIT AND TYPE PER CONDUIT SIZE TYPE DRAWN BY BA 1 3 AWG#12 Q-CABLE NA NA NA 1 AWG#6 BARE,COPPER EGC N/A FREE AIR DATE 9/25/2025 2 6 AWG#10 THWN-2,COPPER NA NA NA 1 AWG#8 THWN-2,COPPER EGC 1" PVC REVISION 3 2 AWG#6 THWN-2,COPPER 1 1 AWG#6 THWN-2,COPPER 1 1 AWG#8 THWN-2,COPPEREGC 1" PVC SIGNATURE E EXISTING WIRES AND CONDUIT PV-4 ELECTRICAL CONTRACTOR AMBIENT TEMPERATURE SPECS OWER RECORD L �ISOLUTIONS RECO OW TEMP -15 PERCENT OF NUMBER OF CURRENT AMBIENT TEMP (HIGH TEMP 2%) 840 VALUES CARRYING CONDUCTORS IN CONDUIT LONG ISLAND POWER CONDUIT HEIGHT 7/8" .80 4-6 SOLUTIONS 2060 OCEAN AVENUE, ROOF TOP TEMP 56° 70 7-9 RONKONKOMA, NY 11779, CONDUCTOR TEMPERATURE RATE 750 631-348-0001 .50 10-20 MODULE TEMPERATURE COEFFICIENT OF Voc -0.25%/°C PROJECT INFO&ADDRESS PATRICK FEDUN CALCULATIONS: 270 HARVEST LN, MATTITUCK, 1. CURRENT CARRYING CONDUCTOR 2. PV OVER CURRENT PROTECTION ...NEC 690.9(B) NY 11962 = TOTAL INVERTER O/P CURRENT x 1.25 30 x 1.33 x 1.25 = 49.88 A SYSTEM SIZE (A) BEFORE IQ COMBINER PANEL ( ) DC SIZE: 13.200 KW DC-(STC) AMBIENT TEMPERATURE - (34)OC ...NEC 310.15(B)(2)(a) -TO THE BEST OF MY TEMPERATURE DEBATE FACTOR - 0.94 ...NEC 310.15(B)(2)(a) BELIEF AND PROFESSIONAL EDGE, JUDGMENT,THE PLANS GROUPING FACTOR - 0.8...NEC 310.15(B)(3)(a) SPECIFICATIONS ARE NAND COMPLIANCE WITH THE 2020 RESIDENTIAL CODE OF NEW YORK �v STATE. CONDUCTOR AMPACIT i�T -IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING = (INV O/P CURRENT ) x 1.25 / A.T.F / G.F ...NEC 690.8(B) UNDER THE DIRECTION OF A LICENSED PROFESSIONAL,TO ALTER AN ITEM IN ANY WAY.IF AN x • ) X .251 [0.94 x 0.81 ITEM BEARING THE SEAL OF A LICENSED PROFESSIONAL IS = 22.11A ALTERED,THE ALTERING LICENSED �)( ) PROFESSIONAL SHALL AFFIX TO SELECTED CONDUCTOR - #10 THWN-2 ...NEC 310.1516 THEIR ITEM THEIR SEAL AND THE NOTATION"ALTERED BY" FOLLOWED BY THEIR SIGNATURE AND THE DATE OF SUCH ALTERATION,AND A SPECIFIC DESCRIPTI TION. ll (B) AFTER IQ COMBINER PANEL �'��'`�, F. o� TEMPERATURE DEBATE FACTOR - 0.94 GROUPING FACTOR - 1 s CONDUCTOR AMPACITY o 07967s = (TOTAL INV O/P CURRENT) x 1.25 / 0.94/ 1 ...NEC 690.8(B) A� _ [(30 x 1.33) x 1.251 / [0.94 x 11 DRAWN BY BA = 53.06 A DATE 9/25/2025 SELECTED CONDUCTOR - #6 THWN-2 ...NEC 310.15(B)(16) REVISION SIGNATURE PV-4.1 ELECTRICAL CALCULATIONS CONTRACTOR WARNING: PHOTOVOLTAIC CopOWER -• - • - WTIONS ELECTRIC SHOCK HAZARD CAUTION IF A GROUND FAULT IS INDICATED POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE LONG ISLAND POWER NORMALLY GROUNDED CONDUCTORSWARNING MAY BE UNGROUNDED AND ENERGIZED [7 ] INVERTER OUTPUT CONNECTION • NOT FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: SOLUTIONS RELOCATEOVERCURRENT DEVICE 2060 OCEAN AVENUE, ©❑ r N RONKONKOMA, NY 11779, 2 I ®.'� w : ,._«• 631-348-0001 ELECTRIC SHOCK HAZARD CAUTION:SOLAR'ELECTRIC I SYSTEM CON gCTED + THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED PROJECT INFO&ADDRESS Fq� 1SOLAR PV SYSTEM EQUIPPED PATRICK FEDUN WITH RAPID SHUTDOWN 270 HARVEST LN, F3] 'I , g ® TURN RAPID SHUTDOWN MATTITUCK, SWITCH TO THE NY 11952 ELECTRIC SHOCK HAZARD "OFF POSITION TO SIXAR EIEGRRC DO NOT TOUCH TERMINALS SHUTDOWN PV SYSTEM PV VANELS AND REDUCE TERMINALS ON BOTH LINE AND SHOCK HAZARD SYSTEM SIZE LOAD SIDES MAY BE ENERGIZED IN THE ARRAY v IN THE OPEN POSITION DC SIZE: 13.200 KW DC-(STC) PV ARRAY 1 �+= -TO THE BEST OF MY KNOWLEDGE, 4 , , •O �+��� ELIEF AND PROFESSIONAL '®'Y� B DGMENT,THE PLANS AND .. Y` -` �J SPECIFICATIONS ARE IN . . o �P COMPLIANCE WITH THE 2020 RESIDENTIAL CODE OF NEW YORK � �x COMBINER PANEL F ° STATE. 5 I WARNING:DUAMPOWER'SOURCE (OUTSIDE HOUSE) x a • • • • Pv DISCONNECT -IT IS A VIOLATION OF THE LAW FOR SECOND SOURCE,IS PHOTOVOLTAIC SYSTEM ANY PERSON,UNLESS ACTING tea-Ryas,.7 D OUTPUT CURRENT39.90AMPS (OUTSIDE HOUSE) • • OPERATING • • • ,/ • UTILITY METER MTS PANEL UNDER THE DIRECTION OF A (UNDERGROUND SERVICE) (INSIDE BASEMENT) LICENSED PROFESSIONAL,TO (OUTSIDE HOUSE) MAIN SERVICE PANEL ALTER AN ITEM IN ANY WAY.IF AN (INSIDE BASEMENT) ITEM BEARING THE SEAL OF A LICENSED PROFESSIONAL IS ALTERED,THE ALTERING LICENSED PROFESSIONAL SHALL AFFIX TO THEIR ITEM THEIR SEAL AND THE NOTATION"ALTERED BY" FOLLOWED BY THEIR SIGNATURE AND THE DATE OF SUCH ALTERATION,AND A SPECIFIC DESCRIPTI RATION. Solar Module Solar Module Micro Inverters -) L E O*1 AC Junction Box COMBINER MANUAL TRANSFER MAIN SERVICE PANEL AC DISCONNECT SWITCH PANEL 1 go T 1 6 2 Outside Door Out3si9e1Door Out3si9e1Door 73,4 3,6,8,9,11 ' Fo 079676 Inside Door Inside Door 111111111111117 ,O � OEM Cables should be marked by the manufacturer Inside Door 5 Inside 5,6,7 *Custom *Custom DRAWN BY BA NEC 690.13(B) Directory Directory NEC 690.54 Placard Placard DATE 9/25/2025 NEC 690.56(C) REVISION NEC 705.12(B)(3) NEC 690.13(B)NEC 705.12(A) NEC 690.13(B) NEC 690.13(B) SIGNATURE NEC 690.56(B)NEC 705.12(B)(3) NEC 690.56(B) NEC 690.56(B) NEC 705.10 NEC 705.10 NEC 705.10 PV-5 NEC 705.12(A) NEC 705.12(A) NEC 705.12(B)(3) NEC 705.12(B)(3) LABELS ka o a• ;fit AR At FRONT ELEVATION AERIAL VIEW tY - r r 1 cr rY 4 w >t cP�oA o�9`6z6 r VIEW FROM RIGHT SIDE OF HOUSE VIEW FROM LEFT SIDE OF HOUSE PANELS ARE NOT VISIBLE FROM STREET _ 1 IHDHYUNDAI eng.hd-hyundaies.co.kr ENERGYSOLUTIONS HD HYUNDAI SOLAR MODULE NF(BK) Series Premium N-Type TOPCon Module HiN-T430NF(BK) I HiN-T435NF(l3K) I HiN-T440NF(BK) J 22.53% cc. 11 I TOP,Con' 22.53% High-End Higher Long Term Compatible For Residential High Efficiency TOPCon Bifaciality Reliability with Carport (Full Black Design) Technology Applications HD Hyundai's Warranty Provisions •HDHESTOPCon Module Certification 99% 0 PERC Standard `w • 0 25 •25 Year Product Warranty ��100%.• Sh k�wa rr�ws Materials and workmanship 89.4% 874yo PVEL 90% :777- • • .IS09001:Quality managementsystems 30-Year Performance Warranty 85% ISO14001:EnVrcnmentalmanagementsystems ISO45001:Occupaticnal health and safety management systems renrts -First year degradation:1% 80� UL61730:ptwtvwltac(Gv)mcdulesaferyquatrcaoon(CSA) Linearwarrdntyafterinitialyear: 0 5 10 15 20 25 30 -IEc617o1:salt mistcorrosi.ntesting with 0.4%p annual degradation, -IEC 62716:lanmorfa cwcson testing 87.4%is guaranteed up to 30years 'Refer to HD HES standard warranty for details. IEC 62804:Potential Induced oegradaWn(PID)testing -IEC 60068-2-68:sand and dust testing fm,envircnmental durabkty Y Electrical Characteristics Y Y Item Unit BNPI BNPI BNPI Nominal output(Pmax) W 430 476 435 482 440 488 Open circuit voltage(Voc) V 38.4 38.4 38.6 38.6 38.8 38.8 Short circuit current(Isc) A 14.25 15.79 14.32 15.87 14.39 15.94 Voltage at Pmax(Vmpp) V 31.9 31.9 32.1 32.1 32.3 32.3 Current at Pmax(Impp) A 13.48 14.94 13.56 15.02 13.63 15.10 Module efficiency % 1 22.02 22.28 22.53 Power Class Sorting W 0-+5 Temperature coefficient of Pmax "/o/K -0.30 Temperature coefficient of Voc %/K -0.25 Temperature coefficient of Isc %/K 0.046 Bifaciality % 80%t10% *STC:Irradiance 1,000 w/m',cell temperature 25C,AM=1.5/Test uncertaintyfor Pmax t3%;Voc t35/6;Isc t3% **The electrical properties of BNPI are measured under the irradiance corresponding to 1000 W/ml on the module front and 135 W/ml on the nodule rear. Additional • • •- Pmpp gain Pmpp[W] Vmpp[V] Impp[A] V0c[V] Isc[A] 5% 458 32.30 14.18 38.80 14.97 15% 493 32.30 15.27 38.80 16.12 25% 528 32.40 16.36 38.90 17.27 *Electrical characteristics with different rear power gain(reference to 440M Mechanical Characteristics Installation Safety Guide Dimensions 1,722mm(L)x 1,134mm(W)x 30mm(H) Only qualified personnel should install or perform (67.8in x 44.6in x 1.2in) maintenance. Weight 24.5 kg(50.01lbs) Solar Cells N-Type TOPCon,108(6x18)monocrystalline 16BB half-cut bifacial cells Be aware dangerous high DC voltage. Ca ble:(+)1,200mm(47.2in),(-)1,200m m(47.2 in)/Custo mized length availa ble Do not handleorinstallmoduleswhentheyarewet. Output Cables Connector:StaubliMC4 genuine Connector/Compatible,IP68 Junction Box 3-part,3 bypass diodes,IP68 rated Nominal Module Operation 44*C t 2°C p Temperature Front:2.Omm(0.08in)semi-tempered solar glass with high transmittance Operating Temperature -40'C-+85*C Construction and anti-reflective coating Rear:2.Omm(0.08in)semi-tempered solar glass Maximum System Voltage DC 1,500 V Frame Anodized aluminum alloy Maximum Reverse Current 30A Maximum Test Load Front 5,400Pa Shipping Configurations `See Installation Manual *Rear5,400Pa Fire Performance I Type 29 Packing Direction Vertical Packing pallet weight(kg) 912 Container Size(HC) 40' Modules Per Pallet(pcs) 36 Pallets Per Container 26 Modules Per Container(pcs) 936 Module Diagram(unit:mm) I-V Curves(HiN-T440NF(BK)) 30tlmmr Current[A] arro4el 1.18s0.04' 16 Bade 14 12 4- � E 10 0.16 2 IIIIff 8 Groruwuml WI �w 32mm t2s• 6 -Operating Cell Temp VC 12:1 4 -Operating Cell Temp=25*C M01II1bfy 8 A-A 2 -operating cell Temp=45*c Q55�'.t0.35{ -Operating Cell Temp=65*C E 0 E� 0 10 20 30 40 Voltage[V] " Current[A] rae4 d-10a7mmr a 0.39x0.2a' E� i6 E 14 -12 Irradiance=1,000W/m' 16-ax3miN 18mm0.71• 10 -Irradiance=800W/m' o.3ao.lr �11112:1 B A is 6 -Irradiance=600W/1' L 4 -Irradiance=400W/m' 84 108 4284t0.08' 1134x 44.65z0.08' 2 -Irradiance=200W/m' 0 0 10 20 30 40 FRONT SIDE REAR Voltage[VI Sales&Marketing HD Hyundai Energy Solutions reserves the rightto update or modify the specifications and features listed in this clatasheet HYUNDAI - hes.sales@hd.com without prior notice.Always check the latest version of the datasheet for accurate information.Before using the product, HD ENERGYSOLUTIONS please refer to the Installation and Operation Manual and Warranty.we retain the right of final interpretation. r r A ENPHASE. i I i 0 I i IQBMC -Microinverter Easy to install Our newest IQ8 Series Microinverters are the industry's first microgrid-forming`,software-Our and compact with plug- defined microinverters with split-phase power conversion capability to convert DC power to and-play connectors AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary Power line communication(PLC) application-specific integrated circuit(ASIC),which enables the microinverter to operate in between components i grid-tied or off-grid modes.This chip is built in advanced 55-nm technology with high-speed Faster installation with simple two-wire digital logic and has superfast response times to changing loads and grid events,alleviating cabling constraints on battery sizing for home energy systems. _ High productivity and reliability ' Enphase Produces power even when the grid is down* More than one million cumulative hours 1 of testing Part of the Enphase Energy System, IQ8 Series Microinverters redefine Class II double-insulated enclosure IQ8 Series Microinverters integrate with reliability standards with more than one Optimized for the latest high-powered the IQ Battery,IQ Gateway,and the million cumulative hours of power-on PV modules Enphase App monitoring and analysis testing,enabling an industry-leading f software. limited warranty of up to 25 years. Microgrid-forming Complies with the latest advanced grid I �® support • Remote automatic updates for the latest grid requirements I Configurable to support a wide range I of grid profiles Connect PV modules quickly and easily IQ8 Series Microinverters are UL Listed to the IQ8 Series Microinverters that have as PV rapid shutdown equipment and Meets CA Rule 21(UL 1741-SA)and IEEE integrated MC4 connectors. conforms with various regulations when 1547:2018(UL 1741-SB) installed according to the manufacturer's instructions. NOTE: • IQ8 Microinverters cannot be mixed together with I previous generations of Enphase microinverters (IQ7 Series,IQ6 Series,etc.)in the same system. • ! *Meets UL 1741 only when installed with IQ System Controller 2 and 3. IQ Gateway is required to change the default gridprofile at the time of installation to meet the local I Authority Having Jurisdiction(AHJ)requirements. r ©2023 Enphase Energy.All rights reserved.Enphase,the a and CC logos,IQ and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy,Inc.in the US and other countries. Data subject to change. IQ8MC-MC4-DSH-00049-3.0-EN-US-2023-10-18 IQ8MC Microinverter INPUT DATA(DC) UNITS .: Commonly used module pairings W 260-460 wModule compatibility To meet compatibility,PV modules must be within the following max.input DC voltage and max.module Ix Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator. MPPT voltage range v 25-45 Operating range v 18-58 Min./Max.start voltage V 22/58 Max.input DC voltage V 60 Max.continuous operating DC current A 14 Max.input DC short-circuit current A 25 Max.module Ix A 20 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration I Ungrounded array;no additional DC side protection required;AC side protection requires max 20 A per branch circuit OUTPUT DATA(AC) UNITS 108MC-72-M-US @240 VAC IQ8MC-72-M-US @208 VAC Peak output power VA 330 315 Max.continuous output power I VA 320 310 Nominal grid voltage(L-L) v 240,split-phase(L-L),180° 208,single-phase(L-L),120° Min./Max.grid voltage P v 211-264 183-229 Max.continuous output current A 1.33 1.49 Nominal frequency I Hz 60 Extended frequency range Hz 47-68 AC short circuit fault current over three A 2.70 cycles " Max.units per 20 A(L-L)branch circuit' 12 10 Total harmonic distortion % <5 Overvoltage class AC port III AC port backfeed current MA 18 Power factor setting 1.0 ; Grid-tied power factor(adjustable) 0.85 leading...0.85 lagging Peak efficiency % 97.4 97.2 CEC weighted efficiency % 97.0 96.5 Nighttime power consumption mW 33 25 MECHANICAL DATA UNITS Ambient temperature range -40°C to 65"C(-40°F to 149°F) Relative humidity range 4%to 100%(condensing) DC connector type Staubli MC4 Dimensions(H x W x D);Weight 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2");1.1 kg(2.43 Ibs) Cooling Natural convection-no fans Approved for wet locations;Pollution degree Yes;PD3 Enclosure Class II double-insulated,corrosion-resistant polymeric enclosure Environ.category;UV exposure rating NEMA Type 6;outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,IEEE 1547:2018(UL 1741-SB),FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017,NEC 2020,and NEC 2023 section 690.12 and C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's instructions. (1)No enforced DC/AC ratio. (2)Nominal voltage range can be extended beyond nominal if required by the utility. (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQBMC-MC4-DSH-00049-3.0-EN-US-2023-10-18 Revision history i REVISION DATE DESCRIPTION DSH-00049_3.0 October 2023 Included NEC 2023 specification in the Compliance section. DSH-00049-2.0 I September 2023 I Updated module compatibility information. DSH-00049-1.0 May2023 Preliminary release. ©2023 Enphase Energy.All rights reserved.Enphase,the a and CC logos,IQ and certain other marks listed at htt2s://enphase.com/trademark-usaae-ouidelines are trademarks of Enphase Energy,Inc.In the US and other countries. Data subject to change. 108MC-MC4-DSH-00049-3.0-EN-US-2023-10-18 ®COL IRON RIDGE Roof Mount System ------------- i. Built for solar's toughest roofs. IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. ® Strength Tested PE Certified All components evaluated for superior Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Software Certified to maintain the fire resistance ® Online tool generates a complete bill of rating of the existing roof. materials in minutes. Integrated Grounding 20 Year Warranty ® UL 2703 system eliminates separate ® Twice the protection offered by moJule grounding components. competitors. XR Rails XR10 Rail XR100 Rail XR1000 Rail Internal Splices Q A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability 8'spanning capability 12'spanning capability Self-tapping screws • Moderate load capability Heavy load capability Extreme load capability Varying versions for rails • Clear& black anod.finish Clear&black anod.finish Clear anodized finish Grounding Straps offered A tachments FlashFoot Slotted L-Feet Standoffs Tilt Legs i - - Lj �_yr- Anchor,flash, and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired with all-in-one attachments. attachment. systems to various heights. angle, up to 45 degrees. • Ships with all hardware High-friction serrated face • Works with vent flashing Attaches directly to rail • IBC& IRC compliant Heavy-duty profile shape • Ships pre-assembled Ships with all hardware • Certified with XR Rails Clear& black anod.finish • 4"and 7" Lengths Fixed and adjustable Clamps & Grounding End Clamps Grounding Mid Clamps Q T Bolt Grounding Lugs Q Accessories i f 1.,.�r- - J Far Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails. • Mill finish &black anod. • Parallel bonding T-bolt Easy top-slot mounting Snap-in Wire Clips • Sizes from 1.22"to 2.3" • Reusable up to 10 times Eliminates pre-drilling Perfected End Caps • Optional Under Clamps • Mill &black stainless Swivels in any direction UV-protected polymer Free Resources Design Assistant ♦ NABCEP Certified Training Go from rough layout to fully a®® Earn free continuing education credits, - ------ engineered system. For free. d , while learning more about our systems. Go to IronRidge.com/rm ♦ Go to IronRidge.com/training o :00 ®��®