50888-Z
�o0, SO(/lyo`o Town of Southold * P.O. Box 1179 �0 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46982 Date: 04/17/2026 THIS CERTIFIES that the building SINGLE FAMILY DWELLING Location of Property: 420 Old Farm Rd Orient, NY 11957 Sec/Block/Lot: 25.-5-8 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 05/08/2024 Pursuant to which Building Permit No. 50888 and dated: 07/01/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Single-family dwelling with an unfinished basement, covered front porch, partially' covered rear deck, outdoor shower, and an attached garage as applied for. The certificate is issued to: 420 Old Farm Rd LLC Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: R-21-0769 4/10/2026 ELECTRICAL CERTIFICATE: 50888 10/16/2025 PLUMBERS CERTIFICATION: Jack Gismondi 3/11/2026 1 CAu a Signature ufFQt TOWN OF SOUTHOLD jo aye BUILDING DEPARTMENT TOWN CLERK'S OFFICE "o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 50888 Date: 7/1/2024 Permission is hereby granted to: Parallel Properties LLC c/o Brian Fuhmann 3201 Vista Dr Manhattan Beach, CA 90266 To: Construct a new single-family dwelling with HVAC system as applied for per SCHD approval. At premises located at: 420 Old Farm Rd, Orient SCTM #473889 Sec/Block/Lot# 25.-5-8 Pursuant to application dated 5/8/2024 and approved by the Building Inspector. To expire on 12/31/2025. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $3,198.00 CO-NEW DWELLING $100.00 Total: $3,298.00 Building Inspector pE SOUr�ol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G O Southold,NY 1 1 971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Parallel Properties LLC Address: 420 Old Farm Rd City: Orient St: NY Zip: 11957 Building Permit#: 50888 Section: 25 Block: 5 Lot: 8 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: REP Electric License No: 46288ME SITE DETAILS Office Use Only Indoor P-1 Basement (v Service W Solar F Outdoor 1701 1st Floor (✓ Pool Spa (- Renovation 2nd Floor I✓ Hot Tub 1' Generator (- Survey I- Attic rrvi Garage rl Battery Storage r INVENTORY Service 1 ph rv�- Heat Duplec Recpt 77 Ceiling Fixtures 24 Bath Exhaust Fan 4 Service 3 ph I- Hot Water 30A GFCI Recpt Wall Fixtures 9 Smoke Detectors Main Panel 200A A/C Condenser 3 Single Recpt Recessed Fixtures 62 CO Detectors Sub Panel 100A A/C Blower 3 Range Recpt Ceiling Fan Combo Smoke/CO 9 Transfer Switch UC Lights 10, Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 44 4-LED Exit Fixtures Other Equipment: Fridge, Oven, DW, Micro, Hood, W/D, ERV, Dehumidifier, 200A Panel 60 Circuit/ 42 Used, 100A Sub Panel 16 Circuit/ 8 Used, (14) 120Combo Breakers, (9)115Combo Breakers Notes: Two Story House w/ Unfinished Basement Inspector Signature: X Date: October 16, 2025 Sean Devlin Electrical Inspector sean.deviinCD-town.southold.ny.us S. Devlin-Cert Electrical Compliance Form 2 �guF [�? �® c®N Town Hall Annex may`® �y t� Telephone(631) 765-1802 54375 Main Road P. O. Box 1179 c OL3 Southold, NY 11971-0959 t�ZZ' .r r r BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: Building Permit No. Owner: (Please print) ` Plumber: Gl� l S QGth` v G (Please print) I certify that the solder used in the water supply system contains les an 2/ 0 of 1% lead. (Plumbers Signature) Sworn to before me this day of 20CAL--v L=` v7a'i .� A��Y • i.. ,_i L Ifs 1 SR , Notary Public, County MAR 1 1 2026 CONNIE D_BUNCH Notary Public,State'&New York No.09'BU6185050 Corn, tl'1riSuffolk.County 1 iviisslon Fx'pl'res Aprll 14,2e)�k zi' �o�*pF SOUTho6 # TOWN OF SOUTHOLD BUILDING DEPT. °yco 631-765-1802 �o I N S P ECT IO N [t.�FO UNDATION 1 ST/ REBAR. [ ] ROUGH PLBG. [. ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE .& CHIMNEY [ ]' FIRE-SAFETY INSPECTION. [ ] FIRE RESISTANT CONSTRUCTION [ ]' FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: (D::rooAl� 46�W DATE --INSPECTOR OF SOUIh°�o * # TOWN OF SOUTHOLD BUILDING DEPT. "coum, 631-765-1802 g INSPECT ON [ ] FOUNDATION 1 ST/ REBAR [ ROUGH PLBG. [ : ] F UNDATION 2ND [ ] INSULATION/CAULKING FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ . ] FIRE SAFETY INSPECTION [ ] 'FIRE RESISTANT CONSTRUCTION [ ] FIRE-RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [. ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [. ] RENTAL 7MARK J DATE INSPECTOR oPSOUTyolo (�l� # # TOWN OF SOUTHOLD BUILDING DEPT: 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] -ROUGH PLBG. [ ] FOUNDATION 2ND [ . ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS:. VO4e,10_je DATE AZq INSPECTOR �� oF souTyOlo Cs�C�. Zle) - # TOWN OF SOUTHOLD BUILDING DEPT. coo 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [- ] FIRE SAFETY INSPECTION ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS:A4 ' --,k t /1 d C4 2n� DATE — INSPECTO pF 50UTyOlo - - -- # TOWN OF SOUTHOLD BUILDING DEPT. eourma�' 631-765-1802 Sow INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULAA-1 TIION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION PRE C/O [ ] RENTAL REMARKS: oi�l ,00 qz" . A;tnk/ o 4 C47 0) u � DATE 110 N64 INSPECTOR ' • • - a • ® PSEG 'ONG s A N D Assessment Results Customer Name: Salim Westvind Assessor Name: Hytech Home Customer Address: 420 Old Farm Rd,Orient,New York,11957 Date of Assessment: May 14,2028 Customer E-mail: swestvind@_gmail.com Air Sealing Air Sealing 1 Air Sealing 2 Square Footage: 2,964 Calculated BAS-CFM50: 3,428 Square Footage: Calculated BAS-CFM50: Conditioned Air Blower Door Reading- Conditioned Air Blower Door Reading- Volume 34,988 CFM50 Pre: 1,826 Volume CFM50 Pre: Did you know? Air sealing is the next defense against heat loss/gain through the leaks in the envelope of the home.A home that is both tight and well ventilated provides the best comfort and energy efficiency.Air sealing improvements can greatly benefit a home,and a ventilation strategy will keep both the building and its occupants healthy and safe.Our partner measured your current building leakage and the minimum airflow standard to be sure that you get enough fresh air if you decide to follow through with implementing weatherization improvements. For more information about measures to help your home with ventilation and sealing improvements,please visit our Energy Efficient Products website to discover available appliance rebates: wvm.pse-gliny.com/saveener-gyandmoney/ener-qvstarrebates Talk to your Home Performance with ENERGY STAR Partner today to find out more about the rebates available for Air Sealing!PSEG Long Island also offers rebates for Windows.Please ask your Home Performance Partner for more information. Seal and 1 Insulate with I ENERGY STAR II fill-;, I. _ PI-TWO ! Rswawd Attic Hatch - DroPPad SOW oust PeQiaer �t� 3i i TOP Praw uv~El Will Fan Sill Plow ` ^' 4 � . c•I -,t OuWoa Foucat n Home Energy Assessment LONG OPSEG ISLAND Assessment Results Customer Name: Salim Westvind Assessor Name: Hytech Home Customer Address: 420 Old Farm Rd,Orient,New York,11957 Date of Assessment: May 14,2028 Customer E-mail: swestvind(olg mail.com Duct Sealing i Heating System 1 Heating System 2 Primary Duct Primary Duct Location: Unconditioned Basement Location: Unconditioned Basement Existing Ductwork Total Ductwork Existing Ductwork Total Ductwork Insulation: Yes Length(ft): 350 Insulation: Yes Length(ft): 200 Existing Ductwork Length of Existing Ductwork Length of Sealed: Yes Ductwork(ft): 300 Sealed: Yes Ductwork(ft): 150 Cooling System 1 Cooling System 2 Primary Duct Primary Duct Location: Unconditioned Basement Location: Unconditioned Basement i Existing Ductwork Total Ductwork Existing Ductwork Total Ductwork Insulation: Yes Length(ft): 350 Insulation: Yes Length(ft): 200 Existing Ductwork Length of Existing Ductwork Length of Sealed: Yes Ductwork(ft): Sealed: Yes Ductwork(ft): 150 I Did you know? In homes with forced hot air heating or cooling systems,ductwork is used to distribute air throughout the home.In a typical home,about 20%of air that moves through the ductwork is lost due to leaks and poorly sealed connections. The result is higher utility bills and difficulty keeping your house comfortable.Exposed ductwork in unconditioned areas like attics,basements,crawlspaces and garages should be repaired with duct sealant.In addition,insulating these ducts that run through unconditioned spaces that get hot in the summer and cold in the winter can save significant energy as well. Talk to your Home Performance with ENERGY STAR Partner today to find out more about the rebates available for Duct Sealing! COMMON DUCT F PROBLEMS o , j;►�t I � _ iL 'Home Energy Assessment ONG ® PSEG ISLAND Assessment Results Customer Name: Salim Westvind Assessor Name: Hytech Home Customer Address: 420 Old Farm Rd,Orient,New York,11957 Date of Assessment: May 14,2028 Customer E-mail: swestvind(a)gmail.com Thermostats and Controls Thermostats and Controls 1 Thermostats and Controls 2 Location: Living Room Thermostat Type: Smart Wi-Fi Location: Basement Thermostat Type: Smart Wi-Fi Heating Set Cooling Set Heating Set Cooling Set Point-High: 70 Point-High: 72 Point-High: 70. Point-High: 72 Heating Set Cooling Set Heating Set Cooling Set Point-Low. 69 Point-Low: 70 Point-Low: 68 Point-Low. 70 Did you know? A smart thermostat is a Wi-Fi enabled device that automatically adjusts heating and cooling temperatures in your home for optimal performance.While system designs may vary,common smart thermostat features include: •0 Ability to learn your temperature preferences and establish a schedule that automatically adjusts to energy-saving temperatures -0 Learning Thermostats learn when you will be home or awake and make sure the house is a comfortable temperature •0 Wi-Fi enabled thermostats allow you to control your home's heating and cooling remotely through your smadphone •0 ENERGY STAR certified smart thermostats quickly enter a low-power standby mode when inactive •0 Smart thermostats provide equipment use and temperature data you can track and manage Choose an ENERGY STAR certified smart thermostat for your home to reduce your energy bills,enhance your comfort and control temperatures based on your preferences and lifestyle.You can receive an additional rebate if you have a central air conditioning system or air source heat pump and install a qualifying smart thermostat that allows PSEG Long Island to make minor,short-term adjustments to your system that reduce power use during periods of high demand for electricity.This can reduce strain on the electric system and save you money.In most cases,you won't even notice adjustments to the central air conditioning system and you'll always have ultimate control. Already have a smart thermostat?Join PSEG Long Island's Smart Savers Program and save money while reducing the strain on the electric system.For more information please visit: https://www.psesliny.com/saveenersyandmoney/Green Enerav/PeakLoad/SmartSavers For more information about Smart Thermostats and available rebates,please visit our online marketplace found here: hftp://www.enerqvfederation.org/pseglin-v-/ e i PSEG LONG A N D Assessment Results Customer Name: Salim Westvind Assessor Name: Hytech Home Customer Address: 420 Old Farm Rd,Orient,New York,11957 Date of Assessment: May 14,2028 Customer E-mail: swestvindna.nmail.com I Lighting Lighting Type: Existing Incandescent%of Lighting: Lighting Type: Existing Incandescent%of Lighting: Location: Existing CFL%of Lighting: Location: Existing CFL%of Lighting: Working: Existing LED%of Lighting- Working. Existing LED%of Lighting: Lighting Type: Existing Incandescent%of Lighting: Lighting Type: Existing Incandescent%of Lighting. Location. Existing CFL%of Lighting: Location: Existing CFL%of Lighting: Working: Existing LED%of Lighting: Working., Existing LED%of Lighting: Lighting Type: Existing Incandescent%of Lighting: Lighting Type: Existing Incandescent%of Lighting: Location: Existing CFL%of Lighting: Location: Existing CFL%of Lighting: Working: Existing LED%of Lighting: Working. Existing LED%of Lighting: Lighting Type: Existing Incandescent%of Lighting: Lighting Type: Existing Incandescent%of Lighting., Location: Existing CFL%of Lighting: Location: Existing CFL%of Lighting: Working: Existing LED%of Lighting: Working: Existing LED%of Lighting: Lighting Type: Existing Incandescent%of Lighting: Lighting Type: Existing Incandescent%of Lighting: Location: Existing CFL%of Lighting: Location: Existing CFL%of Lighting: Working: Existing LED%of Lighting: Working: Existing LED%of Lighting: i i Did you know? PSEG Long Island offers rebates for a variety of ENERGY STAR household appliances and pool equipment.The full list of available rebates and appliances/equipment can be found on our website: I www.osecliny.com/saveeneravandmonevlenergvstarrebates ENERGY STAR LED Lighting-ENERGY STAR certified bulbs use 75%less energy than incandescent bulbs and last 10 to 25 times longer.Switching to more efficient bulbs and fixtures,like ENERGY STAR certified LEDs,is one of the easiest ways to save energy and money. I � LONG ' ® PSEG ISLAND Assessment Results Customer Name: Salim Westvind Assessor Name: Hytech Home Customer Address: 420 Old Farm Rd,Orient,New York,11957 Date of Assessment: May 14,2028 Customer E-mail: swestvindna.gmail.com Appliances Appliance Type: Age: Appliance Type: Age: ENERGY STAR: Working: ENERGY STAR: Working. Location: Fuel Source: Location: Fuel Source: Appliance Type: Age: Appliance Type: Age: ENERGY STAR: Working: ENERGY STAR: Working: Location: Fuel Source: Location: Fuel Source: Appliance Type: Age: Appliance Type: Age: ENERGY STAR: Working: ENERGY STAR: Working: Location: Fuel Source: Location: Fuel Source: Appliance Type: Age: Appliance Type: Age: ENERGY STAR. Working: ENERGY STAR. Working: Location: Fuel Source: Location: Fuel Source: Appliance Type: Age: Appliance Type: Age: ENERGY STAR: Working: ENERGY STAR. Working: Location: Fuel Source: Location: Fuel Source: Did you know? PSEG Long Island offers rebates for a variety of ENERGY STAR household appliances and pool equipment.The full list of available rebates and appliances/equipment can be found on our website: hftps://www.psenliny.com/saveener-gyandmonev/enerqvstarrebates ENERGY STAR Appliances— Every appliance comes with two price tags:the purchase price and the cost of operating the product.ENERGY STAR certified appliances,such as heat pump water heaters,clothes washers,and clothes dryers to help consumers save money on operating costs by reducing energy use without sacrificing performance. Heat Pump Pool Heaters—An energy efficient heat pump pool heater can maximize your energy savings and typically last longer than gas pool heaters.Heat pump pool heaters normally have much lower operating costs because of their higher efficiencies. Smart Strips—Eliminate phantom energy users with this savvy strip.Now you can control the power to devices automatically when the primary device(like a TV set)is off. ENERGY USE OF STANDARD HOUSEHOLD APPLIANCES" Dishwasher 206 kwh Clothes Washer 590 kwh Clothes Dryer L 769 kwh rM Refrigerator 596 kwh L Energy used is based on unit energy consumption in kwh (Source:U.S.EPA) i Home Energy Assessment LONG Window Assessinew Results PSEG ISLAND Assessment Results Customer Name: I Salim Westvind Assessor Name: Hytech Home Customer Address: 420 Old Farm Rd,Orient,New York,11957 Date of Assessment: May 14,2028 Customer E-mail: swestvind(o)gmail.com Windows North Wall Windows East Wall Windows Frame Type: !2c:Double,Vinyl Frame Type: 2c:Double,Vinyl Quantity: i 5 Quantity: 7 Sqft of Windows: 84 Sqft of Windows: 72 U-Value: 0.2 U-Value: 0.2 ENERGY STAR@): I No ENERGYSTARO: No I South Wall Windows West Wall Windows Frame Type: 2c:Double,Vinyl Frame Type: 2c:Double,Vinyl Quantity: 3 Quantity: 9 Sqft of Windows: 64 Sqft of Windows: 76 U-Value: 0.2 U-Value: 0.2 ENERGY STARO: No ENERGY STAR@): No i Did you know? Windows can present weak points in the thermal boundary of your home. If you have single pane windows you may want to consider installing storm windows or insulated double pane glass. ENERGY STAR qualified windows demonstrate energy performance and can save on utility bills. Consumers should use the National Fenestration Ratings Council sticker as a resource to compare window performance with the information listed below: U-Factor measures the rate of heat transfer and tells you how well the window insulates Solar Heat Gain Coefficient(SHGC) measures the fraction of solar energy transmitted and tells you how well the product blocks heat caused by sunliqht Air Leakage(AL) measures the rate at which air passes throuqh joints in the window Visible Transmittance(VT)meal sures the amount of liqht the window lets throuqh I World's Best Window Co. Mill en nium 1000+ UOW�k aW 'np•Ngol s,owE Protlun7�W:VWnIs0da ENERGY PERFORMANCE RATINGS U-Fancr(USAP) Solar Heat UnCoefident 0.35 0.32 ADDITIONAL PERFORMANCE RATINGS YsibleTransmittance Air Leakage(USA-P) 0.51 0.2 Condensation Resistance 51 - i I i I Home Energy Assessment LONG ® PSEG I s A N D Health &Safety Conditions Acknowledgement The conditions indicated below were observed during a limited inspection process.No guarantees are made or implied that all such conditions have been found. Health and Safety Conditions Found: Furnace/Boiler not drafting Gas_Leak, location: 0 Water flooding in basement Water Heater not drafting Notified Utility Company High CO level in Furnace/Boiler vent (Provide date/time and reference numbers) High CO level in DHW vent 0 Infestation: High CO level in oven/stove Unvented space heater Other- High _ Ambient CO level B Unvented dryer Flue gas spilling into conditioned space might result in elevated CO levels,which could cause illness or death Prolonged elevated CO levels could cause illness or death Potential explosive condition may develop Molds/mildew may develop and cause illness Other: Required Actions: Clean/Repair Furnace/Boiler vent and/or chimney Clean oven/stove Clean/Repair Water heater vent and/or chimney Remove unvented Heater Have Furnace/boiler serviced to reduce CO levels Have flooding in basement corrected Have Hot Water Heater serviced to reduce CO levels Get landlord to correct condition Other: - Notes: 'No worst case test performed Sealed unit heat pump no draft or combustion test performed. Moisture Conditions Observed(check all that apply) Inadequate Ventilation e Mold/Mildew � Standing Water Incorrect Venting Condensation Rot Description: Other H&S Conditions Observed(check all that apply) P Str R Sewer B Asbestos Structural Electrical Vermiculite Description: ; i LONG ® PSEG ISLAND Assessment Results Customer Name: Salim Westvind Assessor Name: Hytech Home Customer Address: 420 Old Farm Rd,Orient,New York,11957 Date of Assessment: May 14,2028 Customer E-mail: swestvind cD_gmail.com Heating and Cooling Equipment j Heating System 1 Heating System 2 Equipment Type: Air Source Heat Pump Quantity: 2 Equipment Type: Quantity: Age: <5 1 Working: Yes Age: Working: Fuel Source: Electric' %of Heating Load: 50% Fuel Source: %of Heating Load: Heating Capacity. 18,0001 HSPF: 10 Heating Capacity: HSPF: Efficiency: 300% Efficiency: I Cooling System 1 Cooling System 2 Equipment Type: Air Source Heat Pump Quantity. 1 Equipment Type: Quantity.._ Age: <5 Working: Yes Age: Working: Cooling Capacity: 18,000 %of Cooling Load 0.5 Cooling Capacity: %of Cooling Load SEER. 18 SEER: EER: 12 EER: Did you know? An evaluation of your home's heating and cooling systems is an important component of a home energy assessment.Properly sized heating and cooling equipment is designed to provide heating and cooling,comfortably and efficiently,to a home.HVAC systems that are not selected properly are often oversized.Resultantly, oversized equipment means energy waste;short cycling,reduced equipment life,maintenance issues,air quality issues,and home discomfort.If you are interested in replacing your HVAC system(s),be sure td choose an ENERGY STAR model and have the system sized and installed by a professional.A list of participating contractors can be found on the PSEG Long Island website(see link below). Heat pumps are like air conditioning systems that work in reverse.During the warmer months,the heat pump is used in cooling mode and moves heat from inside the home to outside.During the cooler months;the heat pump is used in heating mode and moves heat from the outside air to inside the home.Yes.You read that correctly;Even the cold winter air contains la certain amount of heat that can be used to warm your home.Unlike typical air conditioning systems and heating systems, a heat pump can provide both heating and icooling from one single unit.From systems that require no duct work to renewable geothermal energy,you can choose the system that's right for you.Heat pumps come in a wide variety of sizes to cover the needs of most any home.There are whole-home solutions for residents,and each earns different rebates.You can choose a ducted system that utilizes your existing ductwork or a ductless system if you have baseboard heating.Heat pumps are sized and configured to specific spaces,capacity needs and comfort preferences. PSEG Long Island offers robust rebates on a variety of compact systems to fit any space.Count on PSEG Long Island to help make your energy efficiency upgrade a fast,easy,and affordable experience.For more information on Heat Pump technology and available rebates,please visit our website or contact us: Website: https://www.psealiny.com/saveenersyandmoney/homeefficiencv/homecomfort/plus Phone: 1-800-692-2626 Email: HomecomfortLl aapseg.com I ,WINTER SUMMER IIA-WdbR COMPRESSOR COMPRESSOR n.. RHriga.ath A,r.nipw.r la SS5 ra ® W.-M r 555 R.nr—m. ,�. ._- h.Dr.rYM ' � iN.nWM I Home EnergyAssessment Domestic Hot 11wei-Assesswent Results ® PSEG LONG A N D Assessment Results Customer Name: Salim Westvind Assessor Name: Hytech Home Customer Address: 420 Old Farm Rd,Orient,New York,11957 Date of Assessment: May 14,2028 Customer E-mail: swestvind(agmail.com Domestic Hot Water Domestic Hot Water 1 Domestic Hot Water 2 Location: Unconditioned Space Fuel Source: Electric Location: Fuel Source: System Type: Coil Energy Factor(EF): 3.7 System Type: Energy Factor(EF): Age: <5 Temperature Setting: 120 Age: Temperature Setting: Did you know? Heating water typically accounts for about 15%of a home's energy use and high efficiency units can use 10 to 25%less energy than standard models,though your energy savings from installing high efficient ENERGY STAR systems will depend on several factors including family size,system location,and appliances.You can make some simple changes to reduce the energy consumed by your water heater by reducing the thermostat setting to 120-125eF.You can also save water and energy by installing low-flow high efficiency showerheads and faucet aerators. For more information about other Energy Conservation Measures and Water Conversation Measures,please visit our online marketplace found here: www.enerqyfederation.or_q/pseglinyAwter-conservation-l.htmI For more information about ENERGY STAR Heat Pump Water Heaters and other available rebates,please visit our Energy Efficient Products website found here: www.psegliny.com/saveeneLqyandmonev/enerqvstarrebates Typical Household Water Consumption by End Use _54E Others IBa[h Dishwasher i teaw f % 1I% •r� Tollet " I4% Clothes Wa sher 17% �1 Shower Ie% Faucets .yip. LONG 0 PSEG ISLAND Assessment Results Customer Name: Salim Westvind Assessor Name: Hytech Home Customer Address: 420 Old Farm Rd,Orient,New York,11957 Date of Assessment: May 14,2028 Customer E-mail: swestvind@gmail.com Insulation Levels Insulation 1 Insulation 2 Location: Rim Joist Location: Existing Existing Area(Sq.Ft): 100 R Value: 14 Area(Sq.Ft): R Value: Recommended Recommended Condition: Good R Value: 14 Condition: R Value: Insulation 3 Insulation 4 I Location: Location: Existing Existing Area(Sq.Ft): R Value: Area(Sq.Ft): R Value: Recommended R Recommended R Condition: Value: Condition: Value: I I Insulation 5 Insulation 6 Location: Location: Existing Existing Area(Sq.Ft): R Value: Area(Sq.Ft): R Value: Recommended R Recommended R Condition: Value: Condition: Value: Did you know? Insulation is your primary defense against losing heating or cooling through your home's thermal envelope(i.e.walls and roofs).It is almost always the first priority in terms of practical cost-effective improvements to a home.The effectiveness of insulation is based on its"R-Value",the standard measure of thermal resistance.A higher R-Value results in slower heat loss/gain,lower energy bills,and is more comfortable home. Installing the correct amount of insulation is key to reducing heating and cooling costs. Think of insulation as a sweater for your home,Ind air sealing as a wind breaker.Installing these two measures together is required to receive PSEG Long Island rebates and ensures your home is operating efficiently and cI mfortably. Talk to your Home Performance with ENERGY STAR Partner today to find out more about the rebates available for insulationl ,16'—,!',,. deep T seep I I ,rts• deep p 'L R-15' eKp R=21 R-38' R-49 lilRecommended Recommended Po Older Rome IJ CadequateFllledJoist' For Most Southern For Northern Older Home Inadequate Climates �� Climates ' � ® Source:ENEI?GY STsW I LONG0 h r PSEGI S L A N 0 202s ��s �a4 MAP► 1 Home Performance with ENERGY STA` ®�� Home Energy Assessment 4 hug P 7 Conducted for: Salim Westvind 420 Old Farm Rd Orient, New York, 11957 5/14/2028 Assessment by: Hytech Home ® PSEGI ONG s A N D Thank you for the opportunity to visit your home! Our Home Performance with ENERGY STAR Program has performed a thorough inspection of your home to test for the overall energy performance and address any concerns you may have. This Home Energy Assessment will provide information to help you understand your energy usage as well as tips and recommendations to help you save more on your energy bill. Be sure to take note of all the PSEG Long Island Energy Efficiency Rebates that are available to you. Home Owner: Salim Westvind Address: 420 Old Farm Rd, Orient,New York, 11957 E-mail: swestvind@gmail.com HPwES Partner: Hytech Home Date of Assessment: 5/14/2028 Year Home Built: 2024 .— �•_.� Number of Occupants: 5 Orientation: East Foundation Type: Basement I certify that the Home Energy Assessment was conducted at the address listed above. Customer Account Number: (Print) I Customer Name: (Print) Customer Email: ;L - (Print) ,I. Customer Signature Date: Auditor Name*: (Print) �i *Auditor's Name,not Company Name Auditor Signature { - Date: _ PSEG Long Island website: htpps://www.psealinv.com/en/saveenergyandmongylomeefficiencv/homeenergvassessment The U.S.Department of Energy(DOE)administers the Home Performance with ENERGY STAR and works in conjunction with the U.S.Environmental Protection Agency(EPA)to support local program sponsors.PSEG Long Island administers the HPwES Program on behalf of its sponsor,the Long Island Power Authority(LIPA). a I.a z t;>< MAR 1 1 2026 `m ?C7. •a. _� —_1 Spray Foam p��ial'is#s 'I 'n �CYffk Radiant Drywall and Insulation Corp. www.Radiani-fnsulSysYems.corr7 1,�O CEO\ tin P O Box 899 ' Middle Island, NY 11953 Ph'one:631-924-0500 Fax:631-924-4584 ElnviroDr�•,ij�;� Commercial Lic:Suffolk:36254-H Residential Lic: Nassau : H1901650000 Certificate of Insulation 3/10/26 Lars Westvind Job site: 420 Old Farm Road Orient, NY Radiant Insulation Systems has supplied and installed the following insulation items. Please see locations and values as listed. House PACKAGE: Demilec Closed Cell Spray Foam installed in Ceiling Slope at 2.5" (R-18.7) ICYNENE Open Cell installed in Ceiling Slope at 9.5" (R-35) Demilec Closed Cell Spray Foam installed in 2 x 6 Exterior Walls at 2" (R-15) R-13 3.625 X 16 Unfaced Fiberglass installed in 2 x 6 Exterior Walls Demilec Closed Cell Spray Foam installed in Joist Ends at 2" (R-15) R-13 3.5 X 16 X 96 UNB installed in Joist Ends Demilec Closed Cell Spray Foam installed in Basement Joist End at 2" (R-15) R-3010 X 16 Kraft Faced Fiberglass installed in Garage Ceiling R-19 6.25 x 15 Kraft Faced Fiberglass installed in Garage Walls Duravent Baffles 22" x 48" Insulation Phase Items White Caulk 101 oz Tubes installed in Insulation Phase Items Fire Caulk 10 oz Tube (Red) - Insulation Phase Items Soudal Window and Door Foam installed in Insulation Phase Items RockWool 3 x 16 x 48 installed in Insulation Phase Items Solar Guard RB Perforated installed in Insulation Phase Items RockWool 3 x 16 x 48 installed in Sound Walls ICYNENE Open Cell installed in Overhang Exterior at 11.5" (R-42) c aniel Costa a Operations , 4 Load Short Form Job: 420 Old Farm Res. +�- wrighsoft° Date: February 19,2026 Entire House By: FR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Project I • • For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Design Information Htg Clg Infiltration Outside db ff) 12 90 Method Simplified Inside db(°F) 70 72 Construction quality Tight Design TD (°F) 58 18 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/lb) 25 49 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF OF) (Btuh) (Btuh) (cfm) (cfm) FCU 1 779 10307 15007 600 600 FCU 2 327 4517 9348 400 400 FCU 3 168 1831 5479 300 300 FCU 4 182 1803 3880 200 200 FCU 5 107 1510 4832 200 200 FCU 6 970 12425 23575 1200 1200 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft" 2026-Feb-25 14:46:39 y���q ..., ., Right-Suite®Universal 2025 25.0.04 RSU54447 Page 1 Z(>* ...Old Farm Residence\420 Old Farm Residence.rup Calc=MJ8 Front Doorfaces: N Entire House 2533 32393 59501 2900 2956 Other equip loads 0 0 Equip.@ 0.95 RSM 56526 Latent cooling 14835 TOTALS i 2533 l 32393 I 71362 I 2900 l 2956 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsofe" 2026-Feb-2514:46:39 �,., Right-Suite®Universal 2025 25.0.04 RSU54447 Paget ...Old Farm Residence\420 Old Farm Residence.rup Calc=MJ8 Front Door faces: N t T . 9 �a.� Load Short Form Job: 420 Old Farm Res. wri ht$o,4 Date: February 19,2026 FCU 1 By: FIR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Project • • For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Design Information Htg Clg Infiltration Outside db(°F) 12 90 Method Simplified Inside db(°F) 70 72 Construction quality Tight Design TD (°F) 58 18 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/lb) 25 49 HEATING EQUIPMENT COOLING EQUIPMENT Make Mitsubishi Electric Make Mitsubishi Electric Trade Mitsubishi Electric Trade Mitsubishi Electric Model MXZ-SM48NAMHZ Cond MXZ-SM48NAMHZ AHRI ref 211289260 Coil SVZ-KP18NA* AHRI ref 211289260 Efficiency 10 HSPF2 Efficiency 13.2 EER2,21 SEER2 Heating input Sensible cooling 12600 Btuh Heating output 0 Btuh @ 47°F Latent cooling 5400 Btuh Temperature rise 0 °F Total cooling 18000 Btuh Actual air flow 600 cfm Actual air flow 600 cfm Air flow factor 0.058 cfm/Btuh Air flow factor 0.040 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.87 Capacitybalance point=0°F ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft) (Btuh) (Btuh) (cfm) (cfm) ZONE#2 410 5270 7029 307 281 ZONE#3 369 5038 7979 293 319 FCU 1 779 10307 15007 600 600 Other equip loads 0 0 Equip. @ 0.95 RSM 14257 Latent cooling 2226 TOTALS I 779 I 10307 I 16483 I 600 I 600 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wwllghtsoft' 2026 Feb 25 14:46:39 Right-Suite®Universal 2025 25.0.04 RSU54447 Page 3 ACa ...Old Farm Residence\420 Old Farm Residence.rup Calc=MJ8 Front Door faces: N •.. Load Short Form Job: 420 Old Farm Res. W{`1 �l�°$®1f Date: February 19,2026 FCU 2 By: FIR Kolb Mechanical 11500 Old Sound Ave.,Maftituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Project Information For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Design Information Htg Clg Infiltration Outside db(°F) 12 90 Method Simplified Inside db(°F) 70 72 Construction quality Tight Design TD (°F) 58 18 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/lb) 25 49 HEATING EQUIPMENT COOLING EQUIPMENT Make Mitsubishi Electric Make Mitsubishi Electric Trade Mitsubishi Electric Trade Mitsubishi Electric Model MXZ-SM48NAMHZ Cond MXZ-SM48NAMHZ AHRI ref 216801482 Coil MSZ-GS12NA*** AHRI ref 216801482 Efficiency 10.7 HSPF2 Efficiency 13.4 EER2,25.6 SEER2 Heating input Sensible cooling 8400 Btuh Heating output 14400 Btuh @ 47°F Latent cooling 3600 Btuh Temperature rise 33 °F Total cooling 12000 Btuh Actual air flow 400 cfm Actual air flow 400 cfm Air flow factor 0.089 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.79 Ca pacify ba lance point=-7°F ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ftz) (Btuh) (Btuh) (cfm) (cfm) MS11 327 4517 9633 400 412 FCU 2 327 4517 9348 400 400 Other equip loads 0 0 Equip. @ 0.95 RSM 8880 Latent cooling 2552 TOTALS I 327 I 4517 I 11432 I 400 I 400 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - wrightsoft- 2026-Feb-2514:46:39 Right-Suite®Universal 2025 25.0.04 RSU54447 Page 4 +� ...Old Farm Residence1420 Old Farm Residence.rup Calc=MJ8 Front Door faces: N T T 9 d Load Short Form Job: 420 Old Farm Res. wri htsoft Date: February 19,2026 FCU 3 By: FIR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Project • • For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Design Information Htg Clg Infiltration Outside db(°F) 12 90 Method Simplified Inside db('F) 70 72 Construction quality Tight Design TD ('F) 58 18 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/lb) 25 49 HEATING EQUIPMENT COOLING EQUIPMENT Make Mitsubishi Electric Make Mitsubishi Electric Trade Mitsubishi Electric Trade Mitsubishi Electric Model MXZ-SM48NAMHZ Cond MXZ-SM48NAMHZ AHRI ref 215748463 Coil MSZ-GS09NA AHRI ref 215748463 Efficiency 10 HSPF2 Efficiency 12.6 EER2,17.4 SEER2 Heating input Sensible cooling 6300 Btuh Heating output 12000 Btuh @ 47°F Latent cooling 2700 Btuh Temperature rise 36 °F Total cooling 9000 Btuh Actual air flow 300 cfm Actual air flow 300 cfm Air flow factor 0.164 cfm/Btuh Air flow factor 0.055 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.71 Capacity balance point=-16 °F ROOM NAME Area Htg load Cig load Htg AVF Clg AVF (ftz) (Btuh) (Btuh) (cfm) (cfm) MS12 168 1831 5946 300 326 FCU 3 168 1831 5479 300 300 Other equip loads 0 0 Equip. @ 0.95 RSM 5205 Latent cooling 2249 TOTALS I 168 I 1831 I 7454 I 300 I 300 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrightsoft" 2026-Feb-2514:46:39 �ti ..,,,..,. -- Right-Su ite®Universal 202525.0.04RSU54447 Pages ZCk ...Old Farm Residence\420 Old Farm Residence.rup Calc=MJ8 Front Door faces: N .; �V `� h ®g a Load Short Form Job: 420 Old Farm Res. I" Date: February 19,2026 FCU 4 By: FIR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Project • • For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Design Information Htg Clg Infiltration Outside db(°F) 12 90 Method Simplified Inside db(°F) 70 72 Construction quality Tight Design TD (°F) 58 18 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/lb) 25 49 HEATING EQUIPMENT COOLING EQUIPMENT Make Mitsubishi Electric Make Mitsubishi Electric Trade Mitsubishi Electric Trade Mitsubishi Electric Model MXZ-SM48NAMHZ Cond MXZ-SM48NAMHZ AHRI ref 216798014 Coil MSZ-GS06NA AHRI ref 216798014 Efficiency 13 HSPF2 Efficiency 21.5 EER2, 35 SEER2 Heating input Sensible cooling 4200 Btuh Heating output 9000 Btuh @47°F Latent cooling 1800 Btuh Temperature rise 41 °F Total cooling 6000 Btuh Actual air flow 200 cfm Actual air flow 200 cfm Air flow factor 0.111 cfm/Btuh Air flow factor 0.052 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.79 Capacity balance point=-21 °F ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) MS13 182 1803 4147 200 214 FCU 4 182 1803 3880 200 200 Other equip loads 0 0 Equip. @ 0.95 RSM 3686 Latent cooling 1051 TOTALS 1 182 1 1803 1 4736 1 200 1 200 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2026-Feb-2514:46:39 WI'1'glflt's® , Right-Suite@ Universal 2025 25.0.04 RSU54447 Page 6 At t ...Old Farm Residence\420 Old Farm Residence.rup Cale=MJB Front Door faces: N . }. 1r1/R`ill ghto Load Short Form Job: 420 Old Farm Res. Date: February 19,2026 FCU 5 By: FR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Project • • For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Design Information Htg Clg Infiltration Outside db(°F) 12 90 Method Simplified Inside db(°F) 70 72 Construction quality Tight Design TD (°F) 58 18 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/lb) 25 49 HEATING EQUIPMENT COOLING EQUIPMENT Make Mitsubishi Electric Make Mitsubishi Electric Trade Mitsubishi Electric Trade Mitsubishi Electric Model MXZ-SM48NAMHZ Cond MXZ-SM48NAMHZ AHRI ref 216798014 Coil MSZ-GS06NA AHRI ref 216798014 Efficiency 13 HSPF2 Efficiency 21.5 EER2, 35 SEER2 Heating input Sensible cooling 4200 Btuh Heating output 9000 Btuh @ 47°F Latent cooling 1800 Btuh Temperature rise 41 °F Total cooling 6000 Btuh Actual air flow 200 cfm Actual air flow 200 cfm Air flow factor 0.132 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.82 Capacity balance point=-24°F ROOM NAME Area Htg load Clg load Htg AVF CIg AVF (ftz) (Btuh) (Btuh) (cfm) (cfm) MS14 107 1510 4938 200 204 FCU 5 107 1510 4832 200 200 Other equip loads 0 0 Equip.@ 0.95 RSM 4591 Latent cooling 1039 TOTALS I 107 I 1510 I 5630 I 200 I 200 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrightsoft" 2026-Feb-25 14:46:39 Right-Suite®Universal 2025 25.0.04 RSU54447 Page XCK...Old Farm Residencel420 Old Farm Residence.rup Calc=MJ8 Front Door faces: N . WE`I h 9 :sot. Load Short Form Job: 420 Old Farm Res. f Date: February 19,2026 FCU 6 By: FR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Project • • For: 420 Old Farm Residence 420 Old Farm Road,Orient, NY 11957 Design Information Htg Clg Infiltration Outside db(°F) 12 90 Method Simplified Inside db('F) 70 72 Construction quality Tight Design TD (°F) 58 18 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/lb) 25 49 HEATING EQUIPMENT COOLING EQUIPMENT Make Mitsubishi Electric Make Mitsubishi Electric Trade Mitsubishi Electric Trade Mitsubishi Electric Model MXZ-SM36NAMHZ Cond MXZ-SM36NAMHZ AHRI ref 213617715 Coil SVZ-KP36NA' AHRI ref 213617715 Efficiency 9 HSPF2 Efficiency 9.5 EER2, 16 SEER2 Heating input Sensible cooling 25200 Btuh Heating output 0 Btuh @ 47'F Latent cooling 10800 Btuh Temperature rise 0 °F Total cooling 36000 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.097 cfm/Btuh Air flow factor 0.051 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.80 Capacitybalance point=0°F ROOM NAME Area Htg load CIg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) ZONE#1 970 12425 23575 1200 1200 FCU 6 970 12425 23575 1200 1200 Other equip loads 0 0 Equip. @ 0.95 RSM 22396 Latent cooling 5719 TOTALS I 970 I 12425 I 28116 I 1200 I 1200 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrghtsaft- 2026-Feb-2514:46:39 Ate:, ,,•, w.�,m Right-Suite®Universal 2025 25.0.04 RSU54447 Page A+(>� ...Old Farm Residence1420 Old Farm Residence.rup Calc=MJ8 Front Door faces: N Building Analysis Job: 420 Old Farm Res. V'Vf ightsoft® g yIS Date: February 19,2026 Entire House By: FIR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Project • • For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Design Conditions Location: Indoor: Heating Cooling Suffolk County AFB, NY, US Indoor temperature(°F) 70 72 Elevation: 67 ft Design TD(°F) 58 18 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 24.6 48.9 Dry bulb(°F) 12 90 Infiltration: Dailyrange (°F) - 16 ( M ) Method Simplified Wet bulb(°F) - 75 Construction quality Tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btuh/ftz Btuh %of load Walls 3.1 9821 30.3 IrfilUaticn Glazing 33.1 12673 39.1 Floors Doors 22.6 897 2.8 VW1 Ceilings 1.7 3170 9.8 Floors 1.7 3171 9.8 03lirgs Infiltration 0.7 2660 8.2 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 32393 100.0 Daarg -Component Btuh/ftz Btuh %of load Walls 0.9 2997 5.0 VIA I Glazing 55.8 21402 36.0 Doors 12.3 487 0.8 Ceilings 1.6 2980 5.0 Floors 0.5 984 1.7 Gad Infiltration 0.1 450 0.8 Girs Ducts 0 0 Ventilation 0 0 Internal gains 30200 50.8 Blower 0 0 Adjustments 0 Total 1 59501 100.0 %arlirgs Latent Cooling Load= 14835 Btuh Overall U-value=0.071 Btuh/fF--°F, Window/Floor Area=15.1 % Data entries checked. Bold/italic values have been manually overridden { wrighr_gc l t 2026-Feb-25 14:46:39 AL. 1 -_ Right-Suite@ Universal 2025 25.0.04 RSU54447 Page 1 ...Old Farm Residence4420 Old Farm Residence.rup Calc=MA Front Door faces: N Building Analysis Job: 420 Old Farm Res. -} - wrightsoft� Y Date: February 19,2026 FCU 1 By: FIR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Project • • For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Design Conditions Location: Indoor: Heating Cooling Suffolk County AFB, NY, US Indoor temperature (°F) 70 72 Elevation: 67 ft Design TD(°F) 58 18 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 24.6 48.9 Dry bulb(°F) 12 90 Infiltration: Dailyrange (°F) - 16 ( M ) Method Simplified Wetbulb(°F) - 75 Construction quality Tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ft' Btuh %of load Walls 3.1 2878 27.9 IrAlbAicn Glazing 33.1 4750 46.1 WAI Boas Doors 0 0 0 Ceilings 1.9 596 5.8 Floors 1.7 1289 12.5 Ceilings Infiltration 0.7 794 7.7 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 10307 100.0 Qaarg —Component Btu hfiF Btuh %of load Walls 0.9 878 5.9 VWI Glazing 51.5 7396 49.3 Doors 0 0 0 Ceilings 2.2 679 4.5 Irtlerd(3�irs Floors 0.5 400 2.7 l� Infiltration 0.1 134 0.9 Ducts 0 0 Ventilation 0 0 Gairg Internal gains 5520 36.8 Blower 0 0 Adjustments 0 Rms Total 15007 100.0 Ojilrgs Latent Cooling Load=2226 Btuh Overall U-value=0.078 Btuh/ft2�°F, Window/Floor Area=18.4% Data entries checked. Bold/italic values have been manually overridden -FJ}- wrightt-.poft- 2026-Feb-25 14:46:39 -•� - Right-Suite®Universal202525.0.04 RSU54447 Paget ...Old Farm Residence\420 Old Farm Residence.rup Calc=MJ8 Front Door faces: N J Building Analysis Job: 420 Old Farm Res. -IMft- wright$oft� g y Date: February 19,2026 1' FCiU 2 By: FIR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Project • • For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Design Conditions Location: Indoor: Heating Cooling Suffolk County AFB, NY, US Indoor temperature(°F) 70 72 Elevation: 67 ft Design TD(°F) 58 18 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 24.6 48.9 Dry bulb(°F) 12 90 Infiltration: Dailyrange(°F) - 16 ( M ) Method Simplified Wet bulb(°F) - 75 Construction quality Tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ftZ Btuh %of load Walls 3.1 1789 39.6 lrhltEfion Glazing 33.1 1587 35.1 Roar Doors 0 0 0 Ceilings 1.2 408 9.0 Floors 1.7 270 6.0 Infiltration 0.7 463 10.3 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Al! Adjustments 0 any Total 4517 100.0 Component Btuh/fl.2 Btuh %of load Walls 0.9 546 5.8 VW Glazing 62.8 3017 32.3 Doors 0 0 0 Ceilings 0.6 203 2.2 Floors 0.5 84 0.9 Q-d Infiltration 0.1 78 0.8 Ducts 0 0 Ventilation 0 0 Irks d Girs Internal gains 5420 58.0 Blower 0 0 Adjustments 0 ON Total 1 9348 100.0 Latent Cooling Load=2552 Btuh Overall U-value=0.066 Btuh/ftz--°F, Window/Floor Area=14.7% Data entries checked. Bold/italic values have been manually overridden wrightsc& ti 2026-Feb-2514:46:39 Rig ht-Suite@ Universal 202525;0.04RSU54447 Page ...Old Farm Residence\420 Old Farm Residence.rup Calc=MA Front Door faces: N Building y Anal sis Job: 420 Old Farm Res. wrigf tsoft® Date: February 19,2026 FCU 3 By: FR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Project • • For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Design Conditions Location: Indoor: Heating Cooling Suffolk County AFB, NY, US Indoor temperature(°F) 70 72 Elevation: 67 ft Design TD (°F) 58 18 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 24.6 48.9 Dry bulb(°F) 12 90 Infiltration: Dailyrange(°F) - 16 ( M ) Method Simplified Wet bulb(°F) - 75 Construction quality Tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ft2 Btuh %of load Walls 3.1 645 35.2 Irriltralim Glazing 33.1 804 43.9 Doors 0 0 0 VWI Ceilings Ceilings 1.2 210 11.5 Floors 0 0 0 Infiltration 0.7 172 9.4 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 oaarg Total 1 1 1831 100.0 Moore We LILIS —Component Btuh/ftz Btuh %of load Walls 0.9 197 3.6 Val Glazing 48.9 1189 21:7 Doors 0 0 0 Cadr>g Ceilings 0.6 104 1.9 Floors 0 0 0 Infiltration 0.1 29 0.5 Gfg Ducts 0 0 Ventilation 0 0 Internal gains 3960 72.3 Blower 0 0 IrilrrEl Gars Adjustments 0 Total 5479 100.0 Latent Cooling Load=2249 Btuh Overall U-value=0.076 Btuh/ft?°F, Window/Floor Area=14.5% Data entries checked. Bold/italic values have been manually overridden -F- wright^goft- 2026-Feb-2514:46:39 `� »• -»-R- Right-Suite®Universal2025 25.0.04 RSU54447 Page 4 ...Old Farm Residence4420 Old Farm Residence.mp Calc=MJB Front Door faces: N Building Anal Job: 420 Old Farm Res. wrightso f� g JV$I$ Date: February 19,2026 FCU 4 By: FIR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Project • • For: 420 Old Farm Residence 420 Old Farm Road,Orient, NY 11957 Design Conditions Location: Indoor: Heating Cooling Suffolk County AFB, NY, US Indoor temperature(°F) 70 72 Elevation: 67 ft Design TD(°F) 58 18 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 24.6 48.9 Dry bulb(°F) 12 90 Infiltration: Dailyrange(°F) - 16 ( M ) Method Simplified Wet bulb(°F) - 75 Construction quality Tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btuh/fF Btuh %of load Walls 3.1 680 37.7 Ir6ltrabm Glazing 33.1 716 39.7 Doors 0 0 0 Oilirgs Ceilings 1.2 227 12.6 Ml Floors 0 0 0 Infiltration 0.7 179 9.9 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 G dng Total 1 1 1803 100.0 Component Btuh/ft2 Btuh %of load Walls 0.9 208 5.4 VWI Glazing 44.7 969 25.0 Doors 0 0 0 Ceilings 0.6 113 2.9 0�� Floors 0 0 0 Infiltration 0.1 30 0.8 Ducts 0 0 Ventilation 0 0 Internal gains 2560 66.0 G�li lrt�(�rs Blower 0 0 Adjustments 0 Total 3880 100.0 Latent Cooling Load= 1051 Btuh Overall U-value=0.070 Btuh/fl:22F, Window/Floor Area=11.9% Data entries checked. Bold/italic values have been manually overridden wrighffi oft- 2026-Feb-25 14:46:39 .. ,• �n Right-Suite®Universal 2025 25.0.04 RSU54447 Page ...Old Farm ResidenceW20 Old Farm Residence.rup Calc=MJ8 Front Door faces: N Building Analysis Job: 420 Old Farm Res. wrightsoft Date: February 19,2026 FCU 5 By: FR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Project • • For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Design Conditions Location: Indoor: Heating Cooling Suffolk County AFB, NY, US Indoor temperature(°F) 70 72 Elevation: 67 ft Design TD(°F) 58 18 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 24.6 48.9 Dry bulb(°F) 12 90 Infiltration: Dailyrange(°F) - 16 ( M ) Method Simplified Wet bulb(°F) - 75 Construction quality Tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/fF Btuh %of load Walls 3.1 514 34.1 IrfiM n Glazing 33.1 716 47.4 ahEr Doors 0 0 0 Oil'" Ceilings 1.2 134 8.8 �I fi Floors 1.7 7 0.4 Infiltration 0.7 139 9.2 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 aadng Total 1 1 1510 100.0 —Component Btuh/ft2 Btuh %of load Walls 0.9 157 3.2 VWI Glazing 93.4 2023 41.9 Doors 0 0 0 Ceilings 0.6 66 1.4 Floors 0.5 2 0.0 Infiltration 0.1 24 0.5 Ir Ducts 0 0 �r>1C�rs Ventilation 0 0 Internal gains 2560 53.0 Blower 0 0 Adjustments 0 Total 1 1 4832 100.0 Cis Latent Cooling Load= 1039 Btuh Overall U-value=0.083 Btuh/ft2--°F, Window/Floor Area=20.2% Data entries checked. Bold/italic values have been manually overridden -Fl*- WMightscft- 2026-Feb-2514:46:39 - _ - - Right-Suite®Universal 2025 25.0.04 RSU54447 Page 6 •� Old Farm ResidenceW20 Old Farm Residence sup Calc=MJB Front Door faces: N Building Analv$IS Job: 420 Old Farm Res. wrightso f g 7 Date: February 19,2026 If� FCU 6 By: FIR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Project • • For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Design Conditions Location: Indoor: Heating Cooling Suffolk County AFB, NY, US Indoor temperature(°F) 70 72 Elevation: 67 ft Design TD (°F) 58 18 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 24.6 48.9 Dry bulb(°F) 12 90 Infiltration: Daily range ff) - 16 ( M ) Method Simplified Wetbulb(°F) - 75 Construction quality Tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btuh/ff? Btuh %of load Walls 3.1 3315 26.7 Irfilt4on Glazing 33.1 4099 33.0 NdI Roos Doors 22.6 897 7.2 Ceilings 1.9 1595 12.8 Floors 1.7 1605 12.9 Infiltration 0.7 913 7.3 Celings Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 D=s Adjustments 0 aaing Total 1 1 12425 100.0 Component Btuh/fF Btuh %of load Walls 0.9 1012 4.3 V"' Glazing 76.0 9428 40.0 Doors 12.3 487 2.1 Ceilings 2.2 1815 7.7 f` , Floors 0.5 498 2.1 Ir�133rs Infiltration 0.1 155 0.7 Ducts 0 0 Ventilation 0 0 Internal gains 10180 43.2 Blower 0 0 Adjustments 0 Total 235751 Du Fly Oilirgs Latent Cooling Load=5719 Btuh Overall U-value=0.067 Btuh/ftl--°F, Window/Floor Area=12.8% Data entries checked. Bold/italic values have been manually overridden vnrrighffiaft- 2026-Feb-2514:46:39 A50 �-» ---a-.M- Right-Suite®Universal 2025 25.0.04 RSU54447 Page 7 0. 9 ...Old Farm Residence\420 Old Farm Residence.rup Calc=MJ8 Front Door faces: N Project Summary Job: 420 Old Farm Res. Wrightsdf t- Date: February 19,2026 Entire House By: FR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Promect Information For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Notes: Design Information Weather: Suffolk County AFB, NY, US Winter Design Conditions Summer Design Conditions Outside db 12 °F Outside db 90 °F Inside db 70 °F Inside db 72 °F Design TD 58 °F Design TD 18 °F Daily range M Relative humidity 50 % Ventilation Method Moisture difference 49 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 32393 Btuh Structure 59501 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32393 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 56526 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 0 Structure 14835 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heating cooling Area(ft2) 2533 2533 Equipment latent load 14835 Btuh Volume(ft') 22797 22797 Air changes/hour 0.11 0.06 Equipment Total Load(Sen+Lat) 71362 Btuh Equiv.AVF(cfm) 42 23 Req.total capacity at 0.70 SHR 6.7 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -� _rw wrila htsoift- 2026-Feb-25 14:46:39 w- ---.«.- Right-Suite®Universal2025 25.0.04 RSU54447 Page 1 ...Old Farm Residencek120 Old Farm Residence.rup Calc=MJ8 Front Door faces: N Wr1��tSQf� Project Summary Job: 420 Old Farm Res. J Date: February 19,2026 FCU 1 By: FIR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Pronect Information For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Notes: Design Information Weather: Suffolk County AFB, NY, US Winter Design Conditions Summer Design Conditions Outside db 12 °F Outside db 90 °F Inside db 70 °F Inside db 72 °F Design TD 58 °F Design TD 18 °F Daily range M Relative humidity 50 % Ventilation Method MJ8 Moisture difference 49 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 10307 Btuh Structure 15007 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 10307 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 14257 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 0 Structure 2226 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling Area(ft� 779 779 Equipment latent load 2226 Btuh Volume(ft3) 7011 7011 Air changes/hour 0.11 0.06 Equipment Total Load(Sen+Lat) 16483 Btuh Equiv.AVF(cfm) 12 7 Req.total capacity at 0.70 SHR 1.7 ton Heating Equipment Summary Cooling Equipment Summary Make Mitsubishi Electric Make Mitsubishi Electric Trade Mitsubishi Electric Trade Mitsubishi Electric Model MXZ-SM48NAMHZ Cond MXZ-SM48NAMHZ AHRI ref 211289260 Coil SVZ-KP18NA* AHRI ref 211289260 Efficiency 10 HSPF2 Efficiency 13.2 EER2, 21 SEER2 Heating input Sensible cooling 12600 Btuh Heating output 0 Btuh @ 47`F Latent cooling 5400 Btuh Temperature rise 0 °F Total cooling 18000 Btuh Actual air flow 600 cfm Actual air flow 600 cfm Air flow factor 0.058 cfm/Btuh Air flow factor 0.040 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.87 Capacity balance point=0'F Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2026-Feb-2514:46:39 .�_- w - Right-Suite®Universal 2025 25.0.04 RSU54447 Page 2 Fa...0ld rm Residenc A20 0ld Farm Residence.rup Calc=MJ8 Front Door faces: N -}� - Project Summary Job: 420 Old Farm Res. ' W ightsoft FCU 2 Date: February 19,2026 Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com --Prooect Information For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Notes: —Design Information Weather: Suffolk County AFB, NY, US Winter Design Conditions Summer Design Conditions Outside db 12 'F Outside db 90 'F Inside db 70 'F Inside db 72 *F Design TD 58 *F Design TD 18 *F Daily range M Relative humidity 50 % Ventilation Method MJ8 Moisture difference 49 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 4517 Btuh Structure 9348 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 4517 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 8880 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 0 Structure 2552 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling Area(ft� 327 327 Equipment latent load 2552 Btuh Volume(ft) 2943 2943 Air changes/hour 0.15 0.08 Equipment Total Load (Sen+Lat) 11432 Btuh Equiv.AVF(cfm) 7 4 Req.total capacity at 0.70 SHR 1.1 ton Heating Equipment Summary Cooling Equipment Summary Make Mitsubishi Electric Make Mitsubishi Electric Trade Mitsubishi Electric Trade Mitsubishi Electric Model MXZ-SM48NAMHZ Cond MXZ-SM48NAMHZ AHRI ref 216801482 Coil MSZ-GS12NA*** AHRI ref 216801482 Efficiency 10.7 HSPF2 Efficiency 13.4 EER2,25.6 SEER2 Heating input Sensible cooling 8400 Btuh Heating output 14400 Btuh @47°F Latent cooling 3600 Btuh Temperature rise 33 'F Total cooling 12000 Btuh Actual air flow 400 cfm Actual air flow 400 cfm Air flow factor 0.089 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.79 Capacitybalance point=-7*F Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ti wrighffioTt• 2026-Feb 25 14:46:39 �•»• �� Right-Suite@ Universal 2025 25.0.04 RSU54447 Page ...Old Farm Residence\420 Old Farm Residence.rup Calc=MJ8 Front Door faces: N ec���� ® � Prot Summary Job: 420 Old Farm Res. FCU 3 Date: February 19,2026 By: FIR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Promect Information For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Notes: Design Information Weather: Suffolk County AFB, NY, US Winter Design Conditions Summer Design Conditions Outside db 12 'F Outside db 90 of Inside db 70 'F Inside db 72 'F Design TD 58 °F Design TD 18 °F Daily range M Relative humidity 50 % Ventilation Method MJ8 Moisture difference 49 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 1831 Btuh Structure 5479 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 1831 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 5205 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 0 Structure 2249 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heating cooling Area(ftJ 168 168 Equipment latent load 2249 Btuh Volume(ft') 1512 1512 Air changes/hour 0.11 0.06 Equipment Total Load(Sen+Lat) 7454 Btuh Equiv.AVF(cfm) 3 1 Req.total capacity at 0.70 SHR 0.6 ton Heating Equipment Summary Cooling Equipment Summary Make Mitsubishi Electric Make Mitsubishi Electric Trade Mitsubishi Electric Trade Mitsubishi Electric Model MXZ-SM48NAMHZ Cond MXZ-SM48NAMHZ AHRI ref 215748463 Coil MSZ-GS09NA AHRI ref 215748463 Efficiency 10 HSPF2 Efficiency 12.6 EER2,17.4 SEER2 Heating input Sensible cooling 6300 Btuh Heating output 12000 Btuh @ 47°F Latent cooling 2700 Btuh Temperature rise 36 °F Total cooling 9000 Btuh Actual air flow 300 cfm Actual air flow 300 cfm Air flow factor 0.164 cfm/Btuh Air flow factor 0.055 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.71 Ca pacity ba lance po int=-16°F Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .� -rk- wrigFtffigf`t- 2026-Feb-25 14:46:39 A= •- �_ Right-Suitep@ Universal 202525.0.04RSU54447 Page Old Zrm' Residence\420 Old Farm Residence.rup Calc=MJ8 Front Door faces: N ec Prot SummaryJob: 420 Old Farm Res. wr ights®ft° FCU 4 Date: February 19,2026 Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Proulact Information For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Notes: Design Information Weather: Suffolk County AFB, NY, US Winter Design Conditions Summer Design Conditions Outside db 12 °F Outside db 90 °F Inside db 70 °F Inside db 72 °F Design TD 58 °F Design TD 18 °F Daily range M Relative humidity 50 % Ventilation Method MJ8 Moisture difference 49 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 1803 Btuh Structure 3880 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 1803 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 3686 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 0 Structure 1051 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling Area(ft� 182 182 Equipment latent load 1051 Btuh Volume(fP) 1638 1638 Air changes/hour 0.10 0.06 Equipment Total Load(Sen+Lat) 4736 Btuh Equiv.AVF(cfm) 3 2 Req.total capacity at 0.70 SHR 0.4 ton Heating Equipment Summary Cooling Equipment Summary Make Mitsubishi Electric Make Mitsubishi Electric Trade Mitsubishi Electric Trade Mitsubishi Electric Model MXZ-SM48NAMHZ Cond MXZ-SM48NAMHZ AHRI ref 216798014 Coil MSZ-GS06NA AHRI ref 216798014 Efficiency 13 HSPF2 Efficiency 21.5 EER2, 35 SEER2 Heating input Sensible cooling 4200 Btuh Heating output 9000 Btuh @47°F Latent cooling 1800 Btuh Temperature rise 41 °F Total cooling 6000 Btuh Actual air flow 200 cfm Actual air flow 200 cfm Air flow factor 0.111 cfm/Btuh Air flow factor 0.052 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.79 Capacity balance point=-21 of Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Rzw Ad- wrightsoft=, 2026-Feb-2514:46:39 •-.»• -»—, Right-Suite®Universal 2025 25.0.04 RSU54447 Page 5 Old Farm Residencel420 Old Farm Residence.rup Calc=MJ8 Front Door faces: N �. Project SummaryJob: 420 Old Farm Res. Wrlghtsoft- F`iU Jr Byte. FFe R ruary 19,2026 Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Promect Information For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Notes: Design Information Weather: Suffolk County AFB, NY, US Winter Design Conditions Summer Design Conditions Outside db 12 °F Outside db 90 of Inside db 70 °F Inside db 72 of Design TD 58 °F Design TD 18 °F Daily range M Relative humidity 50 % Ventilation Method MJ8 Moisture difference 49 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 1510 Btuh Structure 4832 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 1510 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 4591 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 0 Structure 1039 Btuh Ducts 0 Btuh Heat Central vent(0 cfm) 0 Btuh ing Cooling Area(ft2) 107 107 Equipment latent load 1039 Btuh Volume(ft3) 963 963 Air changes/hour 0.14 0.07 Equipment Total Load (Sen+Lat) 5630 Btuh Equiv.AVF (cfm) 2 1 Req.total capacity at 0.70 SHR 0.5 ton Heating Equipment Summary Cooling Equipment Summary Make Mitsubishi Electric Make Mitsubishi Electric Trade Mitsubishi Electric Trade Mitsubishi Electric Model MXZ-SM48NAMHZ Cond MXZ-SM48NAMHZ AHRI ref 216798014 Coil MSZ-GS06NA AHRI ref 216798014 Efficiency 13 HSPF2 Efficiency 21.5 EER2, 35 SEER2 Heating input Sensible cooling 4200 Btuh Heating output 9000 Btuh @ 47°F Latent cooling 1800 Btuh Temperature rise 41 °F Total cooling 6000 Btuh Actual air flow 200 cfm Actual air flow 200 cfm Air flow factor 0.132 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.82 Capacity balance point=-24 °F Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - wrloft® 2026-Feb-2514:46:39 glffts -». --•.-�.�- Right-Suite@ Universal 2025 25.0.04 RSU54447 Page +� ...Old Farm Residence\420 Old Farm Residence.rup Calc=MJB Front Door faces: N Pro ect Summary Job: 420 Old Farm Res. wrightsoft9 FCU 6 Date: February 19,2026 Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Promect Information For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Notes: Design Information Weather: Suffolk County AFB, NY, US Winter Design Conditions Summer Design Conditions Outside db 12 °F Outside db 90 °F Inside db 70 °F Inside db 72 °F Design TD 58 °F Design TD 18 °F Daily range M Relative humidity 50 % Ventilation Method MJ8 Moisture difference 49 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 12425 Btuh Structure 23575 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12425 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 22396 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 0 Structure 5719 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling Area(ft2) 970 970 Equipment latent load 5719 Btuh Volume(ft3) 8730 8730 Air changes/hour 0.10 0.05 Equipment Total Load (Sen+Lat) 28116 Btuh Equiv.AVF (cfm) 14 8 Req.total capacity at 0.70 SHR 2.7 ton Heating Equipment Summary Cooling Equipment Summary Make Mitsubishi Electric Make Mitsubishi Electric Trade Mitsubishi Electric Trade Mitsubishi Electric Model MXZ-SM36NAMHZ Cond MXZ-SM36NAMHZ AHRI ref 213617715 Coil SVZ-KP36NA* AHRI ref 213617715 Efficiency 9 HSPF2 Efficiency 9.5 EER2, 16 SEER2 Heating input Sensible cooling 25200 Btuh Heating output 0 Btuh @ 47°F Latent cooling 10800 Btuh Temperature rise 0 °F Total cooling 36000 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.097 cfm/Btuh Air flow factor 0.051 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.80 Capacity balance point=0°F Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 1 -{k- wri,®h�p - 2026-Feb-25 14:46:39 p �- - .- Right-Suite®Universal 2025 25.0.04 RSU54447 Page �+ ...Old Farm Residence\420 Old Farm Residence.rup Cale=MJ8 Front Door faces: N - wrightsoft' Right-J® Worksheet Job: 420 Old Farm Res. Entire House Date: February 19,2026 By: FR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com 1 Room name Entire House FCU 1 2 Exposed wall 402.0 ft 120.0 ft 3 Room height 9.0 ft 9.0 ft 4 Room dimensions 5 Room area 2533.0 ft' 779.0 ft' Ty Construction U-value Or I HTM I Area (ft') I Load I Area (ft') I Load number (Btu hit t;°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool -----.0 - -- -- -_ 7' _'---_. .._. -- - - - - - 6- --- - 6 V�! 12F-4sw 0.053 n 3.07 0.94 675 626 1925 588 396 357 1097 335 -G 1 D-c2ow_-___ .___- 0.570 ._n _ 33.06 __20.97 _ _ 49 __ --0 _1609 __1021 _ ._-..._39 _ .._ --0 _. __1289 8.18 V�/ 12F-4sw 0.053 a 3.07 0.94 1134 993 3054 932 270 198 609 186 _ 1D_c2ow _ _ _0.570 _ e _-33.06 _ 62.85- _141 _ 0 4650 8841_ __72 _v--0_____2380..__ _ 4525 11 VL12F-4sw 6.063 ,s 3.0- 0,94 675 631 1940 .592 180 180 553 169 1D-c2ow 0.570 s 33.06 34.51 23 0 760 794 0 0 0 0 11D0___ _. __..0.390_. s__,_22.62..- 12.28 _ __ _-21 _ __21 . .. __475____ _ 258 _-0 ___ 0 _ 0. _ ._0, 12F-4sw 0.053 w 3.07 0.94 1134 944 2903 886 234 201 619 189 1D-c2ow 0.570 w 33.06 62.85 171 0 5653 10747 33 0 1080 2053 __----0,390._,W ,.� 22.62 12,28 - 19 19_.. 422 229 .._ .... ._.__.,8 _0 -0 C- ____ 16X19--30ad___ ._.:__,. ____.0.032_ .._ ____,1.25 s_ 0.62 ..784 ._ _784 _97,9____._ 486 _ __e __0 _____0_ -____._0. _ _ .0 C _ Cpartceilma _ 0.033 ._- ___1.94 2.20. __,- 1132_. 1132 21922494 .m_308 - ____308 596, -_679, F_ _19A-36bswp__ _ ._ 6.034 _-_._. 1:65, ',___0.51 _ __167 ____.._. 167 _.____2Z6 ,. ___86 ___ -._,0__ ...____Q,._____..0 0. _19A-30bswp______,__ -.___0 034 1.65 _ 0.51_ _._ 1749 _ 1,749 __2895_ 898 - 779 __779_-_�1289._ ._ 400 6 c)AED excursion 1 01 1 10 Envelope loss/gain 1 29733 28851 1 1 9513 9353 12 a) Infiltration 2660 450 794 134 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 20 4600 4 920 Appliances/other 25600 4600 Subtotal(lines 6 to 13) 32393 59501 10307 15007 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 32393 59501 10307 15007 15 Dud loads 0% 0% 0 0 0% 0% 0 0 Total room load L I Air required(cfm) I I 32393 2900I 59101 2956I I 10307 007 600 I 15600 I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -Fi.F wr�gf�lsatYCC- 2026-Feb-25 14:46:39 Rig ht-Suite®Universal 2025 25.0.04 RSU54447 Pagel Old Farm Residence\420 Old Farm Residence.rup Calc=MJ8 Front Door faces: N -+ wrightsoft° Right-J® WOrksheet Job: 420 Old Farm Res. Entire House Date: February 19,2026 Kolb Mechanical By: FR 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com 1 Room name FCU 2 FCU 3 2 Exposed wall 70.0 ft 26.0 ft 3 Room height 9.0 ft 9.0 ft 4 Room dimensions 5 Room area 327.0 ft' 168.0 fN Ty Construction U-value Or I HTM: I Area (ft') I Load Area (W) Load number (Btuh/ft-°F (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool -- - -- - --- -- - - 6 VI!-- 12F-4sw 0.053 n 3.07 0.94 0 0 0 0 0 0 0 0 � ( 1D-c2o _0.570 __n.- _- 33.06, _ 20.97, :_0 _0 ..._ ____0 . _ __O __ -_0,- _ 0. _0 0. LV)/ 12F-4sw 0.053 a 3.07 0.94 207 183 562 171 108 96 294 90 _._._. .-1D=c2ow,__ __ ._. _ __02570 a 33.06 -__ 62.85 _ -_24 _ __0 -,_,804-_- „-1529 a 12__ _ _11_-0 -_ 408 775- 11 12F-4sw 0.053 -s 3.07 0.94 90 90 277 64 N 126 4 35o lo7 1D-c2ouv 0.570 s 33.06 34.51 0 0 0 0 12 0 397 414 11DO - _,_ _ ._ _ _--_0.390 _s__ 22.62.-- _12.28 ___--0 _ -- __0 _ ---0 -- -0 _ _. .___O _-- _ 0------ - 0 _ -- 0 12F-4sw 0.053 w 3.07 0.94 333 309 951 290 0 0 0 0 _ pppp 1D-c2ow 0.570 w 33.06 62.85 24 0 782 1487 0 0 0 0 �LL��— 11 DO __ 0.390 w 22.62 12.2E 0 0 _. 0 0 0 0 0 0 C _ __ 16X7930ad___ ___ _0.032 1.25. _._.0.62 _. _327 _327__. __408- ___.203 168-__ : 166 _ __ 210 __104 C _ C part ceiling. 0.0.33 _ __ 1.94 ___ 2.20 0 _ 0 _ _ -----0 _ 0 _ 0 0 0 _ 0 -_F ____ 19A-30bswp__._ _ ___0.034 _ 1.65,,___ 0.51 ___163 — 163 _ __ 270 _ _- 84, - -_ --0 _____0 _. 0 0 F 19A-30bswo_ -- --- -0.034 ---1-65 _. 0`51. . . _., 0 - _O --0 _O - 0 61 c)AED excursion 01 1 1 0 Envelope loss/gain 4054 3849 1659 1490 12 a) Infiltration 463 78 172 29 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 2 460 Appliances/other 4500 3500 Subtotal(lines 6 to 13) 4517 9348 1831 5479 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4517 9348 1831 5479 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Totl room loadAirrequiir d517 (cfm) I I 4400I 9348 400I I 1479 300 1131 5300 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 1F wrig�tsoYY 2026-Feb-25 14:46:39 ^-^^- Right-Suite(D Universal 2025 25.0.04 RSU54447 Paget Old Farm Residence1420 Old Farm Residence.rup Calc=MJ8 Front Door faces: N - wrighfisoft Right-M WOrksheet Job: 420 Old Farm Res. Entire House Date: February 19,2026 By: FIR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com 1 Room name FCU 4 FCU 5 2 Exposed wall 27.0 ft 21.0 ft 3 Room height 9.0 ft 9.0 ft 4 Room dimensions 5 Roam area 182.0 ft' 107.0 ft' Ty Construction U-value Or I HTM I Area (ft') Load I Area (ft') Load number (Btuh/ft'-°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Coot Gross N/P/S Heat Cool Gross N/P/S Heat Cool - -- _ - - - 6 Vl/ 12F-0sw "'0 053 n 3.07 0.94 126 116 358 109 90 90 277 84 L -G 1D-c2ow___-_ ._. _ _-0.57,0 .n 33,06. 20.97 _10 0 MO 203 ___..__ 0 _ _ 0 __. __0 _ _0 I12F-4sw 0.053 a 3.07 0.94 117 105 323 99 0 0 0 0 -----C-.1 D-c2ow,. -- - --- 0.570 v e_ 33.06 __ 62.85 - 12---- 0 - -- 397 - 754--------0 0- --0 11 12F-4sw 0.053 s 3.07 0.64 0 0 0 0 0 0 0 0 1 D-c2ow 0.570 s 33.06 34.51 0 0 0 0 0 0 0 0 _ __- ____0.390 __s _ _- 22.62 _.__12.28 _. .. 0 _-'._0 - ._-----0. ____0 _----__0. 12F-4sw 0.053 w 3.07 0.94 0 0 0 0 99 77 238 73 1D-c2ow 0.570 w 33.06 62.85 0 0 0 0 22 0 716 1362 11D0 _ 0.390 _w 22.62 12.28 0 _ 0 _ 0 0 _ _ 0 _0 _0 __ 0 C_ -_ 16X19-30ad__ -. _0.032 __e _^'1.25 _._-0.62 _ -.182 _ _ 182._- 227------ _.113 ___,._107 _-__ 107 _134 66 part ceilinu._-----_ _0.033 - --.- 1,94 ___ _2.20 ----- --0 _--- --_-.0.-. 0 ---_ -0.___ _ 0 ._. -__0 __--0. 0 E __.19A-30bswp,v _ - __0.034 -_ __1.65..___0.51 . __ 0 0. 0__-. __ 0.-__ __4 __ _A _7 2. F _ 19A-30bswp- -- ¢034 -_- - 1.65 --_0.51 ----� --- 0 - ___0-- --0 - 0 -___0 - - 0 61 c)AED excursion 1 121 1 1 661 Envelope loss/gain 1624 1289 1 1371 2249 12 a) Infiltration 179 30 139 24 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 2100 2100 Subtotal(lines 6 to 13) 18031 38BOI 1510 4832 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1803 3880 1510 4832 15 Dud loads 0% 0% 0 0 0% 0% 0 0 Total room 1Air requi dload 880 (cfm) I I I 1200 803 3200I I 12001510 832 4200 I Calculations approved by ACCA to meet all reouirements of Manual J 8th Ed. -P}f wr/gta7ttsotf t^ 2026-Feb-25 14:46:39 -� �-- -� Right-Suite®Universal 2025 25.0.04 RSU54447 Page 3 Old Farm Residence\420 Old Farm Residence.rup Calc=MJ8 Front Door faces: N -r - wrightisoft' Right-M WorkSheet Job: 420 Old Farm Res. Entire House Date: February 19,2026 Kolb Mechanical By: FR 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com 1 Room name FCU 6 2 Exposed wall 138.0 ft 3 Room height 9.0 ft 4 Room dimensions 5 Room area 970.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area Load number (Btuh/fV.-F (Btuh/ft') or perimeter (ft) I (Btuh) or perimeter Heat Cool i Gross N/P/S j Heat I Cool j Gross I N/P/S j Heat Cool 6 yy/1 12F4sw 0.053 n 3.07 0.94 63 0194 59 1D-c2ow__ - - 0.570 _n_ 33.06 - 20.97_..- ---- 0 -- 0 - .___0_ ___0 -- _ - - - - --.- - - - - V+/ 12F-4sw 0.053 a 3.07 0.94 432 412 1266 386 G 1 D-c2ow 0:570 a 33.06 6.2.85 20 _ _ 0 _ 661 1257 11 12F-4sw 6.653 s 3.07 0.94 279 247 759 232 G 1D-c2ow 0.570 s 33.06 34.51 11 0 364 .380 L-D 11D0_ _ 0.390 s _ 22.62.___12.28 ____ -_21 _ _ _21 ._-475 _ _258 12F-4sw 0.053 w 3.07 0.94 468 356 1095 334 1 D-c2ow 0.570 w 33.06 62.85 93 0 3075 5845 11D0 0:390 w 22.62 12.28 19 19 422 229 C _ _ -16X19-30ad__ __ _0.032 _= 1.25. _. _0.62 _, __0 _0 0 _ _ _`_.0- __0 C _. C_Part ceiling. _ _ _ 0.033- _ - _ t94- 2.20 _ 824_- __ 824 1595 __ _1815 - F _.___ .19A-30bswp--•. _ ---0.034-_ -_ __ 1.65 ---_ 0.51 _ -0 _ _ _-- 0 _ _ _ 0 -- -_0_ F 19A-30bswo--.-_-4_ 0.034 1A5- __0.51„ .T _ -970 _.__- 970 _ _1605. 98 61 c)AED excursion 1947 Envelope loss/gain 1 11512 13241 12 a) Infiltration 913 155 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 6 1380 Appliances/other 8800 Subtotal(lines 6 to 13) 12425 23575 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 12425 23575 15 Duct loads 0% 0% 0 0 Total room load 12425 23575 Air required(cfm) 1200 1200 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -Fla =!Ilmh ts4 f t" 2026-Feb-25 14:46:39 r�._ Right-Suite®Universal 2025 25.0.04 RSU54447 Page Old Farm Residence\420 Old Farm Residence.rup Calc=MA Front Door faces: N + wrighUofta Right-J® Worksheet Job: 426Old Farm Res. FCU 1 Date: February 19,2026 By: FIR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com 1 Room name FCU 1 ZONE#2 2 Exposed wall 120.0 ft 62.0 ft 3 Room height 9.0 ft 9.0 ft heattcool 4 Room dimensions 1.0 x 410.0 ft 5 Room area 779.0 ft' 410.0 ft' Ty Construction U-value Or HTM I Area (ft') Load I Area (ft') Load number (Btuh/ft'-°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Vjl -12F-4sw - 0.053 n 3.07 0.94 396 357 1097 335 279 249 766 234 1D^c2ow.._- ____ 0.570 _n_ 33.06 _ _20.97 ._____39_ _ _0 .___1289 818 .__30._. __0.. _-. .981, __ 622 Vl/ 12F-4sw 0.053 a 3.07 0.94 270 198 609 186 45 45 138 42 A_ _, 1D-c2ow_ --0.570._e._- -33.06- _..._62.85_ _._._72 -- -0 -2380 -4525 _ 0 ---0 ---Q ._._._0. 11 12F-4sw 0.053 s 3.07 0.94 180 180 .553 169 54 54 166 51 _ 1D-c2ow 0.570 s 0.00 0.00 0 0 0 0 -0 0 0 0 _11D0_.__-- ____ __ -__0.390 _s_ -.--0.00. --0.00, ____-_._0.._ -- -0 _-- __ 0 -_-- _-_0 _-- 0. _ :-_0 -0 _. 0 L 12F-4sw 0.053 w 3.07 0.94 234 201 619 189 180 147 453 138 1D-c2ow 0.570 w 33.06 62.85 33 0 1080 2053 33 0 1080 2053 _`.. 11D0 _--__ 0.390 _w_ __- OAO .-.0_00 _--._-_ 0 _ --__ 0_ 0 0 0 0 C___._16X19-30ad:_._ .. - _.0.032- _-0.00 .,- 6.66 ____---0 _.a._ __0 __0 --- _ 0- _0__ _ -- -0-- _- __0 C _-_ C part ceiling., -__ __0033- ____ _1.94-- _2.20._ 308 308 _-596 - ___679 308 ._308 596 679. F__ 19A,30bswp_ _ -- - 0.034__- - _ _0.00 ___0.00 .- __0 __.� -0 0-_____.__a0- --- ___0___ ___0 -0 F-.- 19A_30bswp__._. _. 0.034 _ ___1-,65 _,^0.51 _779 __779 -1289 _- 400......410 410 61 c)AED excursion 01 1 1 1 170 Envelope loss/gain 9513 9353 1 1 4859 4199 12 a) Infiltration 794 134 410 69 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 2 460 Appliances/other 4600 2300 Subtotal(lines 6 to 13) 10307 15007 5270 7029 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 10307 15007 5270 7029 15 Duct loads 0% 0% 0 0 -0% 0% 0 0 Total I Airrrequr dload(cfm) I I I 10600I 156000071 I I 53072701 7281I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. L f wr�gtitsoYC` 2026-Feb-2514:46:39 -�- Right-Suite@ Universal 2025 25.0.04 RSU54447 Page 5 Old Farm Residence1420 Old Farm Residence.rup Calc=MJB Front Door faces: N -V wrightsoft Right-J® Worksheet Job: Fe Old Farm Res. FCU 1 Date: February 19,2026 Kolb Mechanical By: FR 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com 1 Room name ZONE#3 2 Exposed wall 58.0 ft 3 Room height 9.0 ft heat/cool 4 Room dimensions 1.0 x 369.0 ft 5 Room area 369.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area Load number (Btuh/ft'-°F (Btuh/fe) or perimeter (ft) (Btuh) I or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V)! 12F-4sw. 0.053 n 3.07 0.94 117 108 331 1D.c2ow_____ _ _ -0570 -_n -. 33.06 _20.97 _..__:e9 _ _0 ____309 196 VI/ 12F-4sw 0.053 a 3.07 0.94 225 153 470 144 - - i_-__ 1 D_c2ow_-__ __ ____0.570 _ e_ _ __33.06 _..__62.85_ ____ 72 0 _ 2380 _ 4525 11 12F-4sw 0.053 s 3.07 0.94 126 126 387 118 ----- - - _—G 1D-c2ow 0.570 s 0.00 0.00 0 0 0 0 _.—D _1_1D0____ _.._ _ _.__0.390_ s - ---0.00,__ --0.00---------A______-0, -----._.0.--- - --0 12F-4sw 0.053 w 3.07 0.94 54 54 166 51 1 D-c2ow 0.570 w 33.06 62.85 0 0 0 0 11 DO 0.390 w __0.00 0.00 _ 0 _ 0 0 0 C_--_-16X1930ad____ -_r0.032 �_ _0.00. __ ___ 0.00 —_0 _ 0. _0 D.__.-_ C part ceilinq.___ _ 0.033_ -1_94 ___2.20 - - F--- 19A-30bswp.--- --0.034 -0- - -0 -_-0 - -0 -- - F _ 19A-30bswp-- - - -- -- - _0,034 _:_- _7.65 _ _0,51 _. 369 _ 369 _ ,611 -_ 190,_ 61 c)AED excursion 1 -170 Envelope loss/gain 1 4654 5154 12 a) Infiltration 384 65 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 2 460 Appliances/other 2300 Subtotal(lines 6 to 13) 5038 7979 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 5038 7979 15 Duct loads -0% 0% 0 0 Air requi dIoad(cfrn) I 511311 293I 7979 319I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -Fk- w'fotmt=orv- 2 026-Feb-25 14:46:39 Right-Suite®U niv er sal 2025 25.0.04 R S U 54447 Page 6 Old Farm Residence\420 Old Farm Residence.rup Calc=MJ8 Front Door faces: N -wrightsoft' Right-M Worksheet Job: 420 Old Farm Res. FCU 2 Date: February 19,2026 By: FIR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com 1 Room name FCU 2 MSI1 2 Exposed wall 70.0 ft 70.0 ft 3 Room height 9.0 ft 9.0 ft 4 Room dimensions 5 Room area 327.0 ft' 327.0 ft' Ty Construction U-value Or I HTM I Area (ft') I Load I Area (ft') Load number (Btuh/ft'-°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool i Gross I N/P/S j Heat Cool 6 VI! 12F-4 0.053 n 0.00 0.00 0 0 0 0 0 0 0 0 --G 1D_c2s,w_,_ - --. -- -0.570. n_ _0.00 _._ 0.00 _-- _0 - - - .0 - - - 0. _ _ .-0 _-0 -- - -- _0_---_.---0 0_ 12F-4sw 0.053 a 3.07 0.94 207 183 562 171 207 183 562 171 --- 1 D-c2ow _ _ ,_ _-0.570 ._e _ 33.06 _62,85 __-__24 _ . 0_ 804 _1529 _24_ . 0 __804- -_ 1529 11 VL12F-4sw 0.053 s 3.07 '0.94 90 90 277 84 90 90 277 84 1D-c2ow 0.570 s 0.00 0.00 0 0 0 0 0 0 0 0 11DO___ -_0.390---s- 0.00 . .__0.00._ _ ___0 _._- 0- --0 ._-_ _._'__0 _______0 ______0_ <__ 0 _ _ 0 12F-4sw 0.053 w 3.07 0.94 333 309 951 290 333 309 951 290 1D-c2ow 0.570 w 33.06 62.85 24 0 782 1487 24 0 782 1487 11 D0 9 390 w 0.00 0.00 0 0 0 0 -0 ____-A C_ 16X19-30ad 0.032. _. _ __,_1.25 .-.0.62 _ 327 ____..327 _-_-.408_ -__203 ___.. 327 M :32Z ___408_408 _ _ __203 C___ _ C part ceiling _. 0.033 _ .,. 0.00 0:00 _ ._0 _-. _, 0 -_--_ 0,._ __.. 0 _- 0.v._-•-0-- _ _0- _ _-- 0 F. _ .19A-30bswp-__,- 0.034___ 1.65 _v_0.51 _163 .____ 163 _ __. 27,0.- .m ,- 89 -_ 163 ____ 163_ ...___270 _� __84 -0,034 :.--_ .__0.00 _____0.00 _--_ - 0_-1--- -0 ..__-- 0 W__. 0 __-._ -0 -- _ __0 e._ _A 0 61 c)AED excursion 01 1 1 1 285 Envelope losstgain 4054 3849 1 1 4054 4135 12 a) Infiltration 463 78 463 78 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 4 920 Appliances/other 4500 4500 Subtotal(lines 6 to 13) 4517 9348 4517 9633 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4517 9348 4517 9633 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 45171 93411 I 41171 9633IAirrequired(cfm) 400 400 12 I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. f}I- wr/g0-�Csoft" 2026-Feb-2514:46:39 �� -+---^ Right-Suite®Universal 2025 25.0.04 RSU54447 Page Old Farm Residence\420 Old Farm Residence.rup Calc=MJB Front Door faces: N wrightsoft Right-JO Worksheet Job: 420 Old Farm Res. FCU 3 Date: February 19,2026 Kolb Mechanical By: FIR 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com 1 Room name FCU 3 MSI2 2 Exposed wall 26.0 ft 26.0 ft 3 Room height 9.0 ft 9.0 ft 4 Room dimensions 5 Room area 168.0 ft' 168.0 ft2 Ty Construction U-value Or I HTM Area (ft') I Load I Area (W) I Load number (Btuh/ftz-F (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool - I - - - -- ----------- 6 V►I 2F-4sw 0.053 n- -0.00 0.00 0 � 0 0 0 0 0 0- T0 _ G DYc2ow --- -- --- 0.570 n 0.00. _ - 0.00 --_-. -0 - - 0 ____0 _ .-0 0. 12F-4sw 0.053 a 3.07 0.94 108 96 294 90 108 96 294 90 1 D-c2ow. 0.570 a 33.06 62.85 ___ 12 0 408 775 _ __ 12 0_ _ 408 775 11 VL12F-4sw 0.053 s 3.07 0.94 126 114 350 107 126 114 350 107 1D-c2ow 0.570 s 33.06 34.51 12 0 397 414 12 0 397 414 11D0 __. __ ____._..0.390 s 0.00:_ 0.00 _0 ,__._ __0 __._ ._0 ._ 0 0___ - _ 0_._= ..- 0 _. _0 12F-4sw 0.053 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ow 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 11 D0 0.390 w 0.00 0.00_16X19-30ad 0 0 0 _ _0 _ _0- ,_ 0 ______0_ _C_ _-_ ..__ _, _0_' ._ __ ..0.032 r. __..L25. __.0.62 :_ _168 _ ..168 _.210 __._ 104.._ ___168_ _ - 168_. ..,__ 210 .__ 104 C_-_ _C Part ceiling. --0.033 - - 0.00 �---OAO.--- 0 ,- _ _.__0 _._---__0 .._.__0 _ _0 --. - .-0------ ---0 - 0 F_.-_-, 19A-30bswp ._ __ _0.034 _. ___0.00 _._0.00_____ 0 __ _0 ___0.-_ __0 __ ___0 __.0_______0 F. 19A-30bswp_. -- 0.034. .___. _0.00 --_0.00 -- - _0. - ° - -0 - _---0 - . 61 c)AED excursion 01 1 466 Envelope loss/gain 1 1659 1490 1 1 1659 1956 12 a) Infiltration 172 29 172 29 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 3500 3500 Subtotal(lines 6 to 13) 1831 5479 1831 5946 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1831 5479 1831 5946 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 1831 5479 1831 5946 Air required(cfm) I I 300I 300I 300 326 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - =!01.12;sof t- 2026-Feb-2514:46:39 Right-Suite®Universal 2025 25.0.04 RSU54447 Page 8 Old Farm Residence\420 Old Farm Residence.rup Calc=MA Front Door faces: N wrightsoft R Fe Right-JO Worksheet Job:J. Old Farm Res. FCU 4 Date: February 19,zozs By: FIR Kolb Mechanical 11500 Old Sound Ave.,Matfituck,NY 11952 Phone:(631)298-5527 Email:info@koibmechanical.com 1 Room name FCU 4 MSI3 2 Exposed wall 27.0 ft 27.0 ft 3 Room height 9.0 ft 9.0 ft 4 Room dimensions 5 Room area 182.0 ft' 182.0 ft' Ty Construction U-value. Or I HTM Area (ft.) I Load I Area (ft') I Load number (Btuh/ft F (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool - - ---- ---- ------_ - -- --- - - - - 6 _- 12F-4sw - -- - - 0.053 n - - 3.07 6.94 126 116 358 109 126 116 358 109 JD-c2ow_ _-__.____ _ ._ 0.57.0. n___..33.06 __20.97 10 _-_0__._ ._320 __ _203 _ __10 _._ ___0 320 _ 203 12F-4sw 0.053 a 3.07 0.94 117 105 323 99 117 105 323 99 -1 D-c2ow_�_.�___.___ _ 0.570.-e_ --33.06 _ 62.85 _-._12 --___-. 0 _,____397 ---..754 --__-_--12 _-___-- 0_T__397 _.__ 754 11 12F�sw 0.053 s 0.00 0.00 0 0 0 0 0 0 0 , 0 1 D-c2ow 0.570 s 0.00 0.00 0 0 0 0 0 0 0 0 _ 11DO-_.. 0.390 _ s- ----0.00, .__0.00 ______. -0_.__.-__0-.-__4_>0 __.__..__0_..___ _ 0. __ _0 _0. _._._ _-.0 it 0.053 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ow 0.670 w 0.00 0.00 0 0 0 0 0 0 0 0 11 DO 0.390 w 0.00 0.00 0 0 0 0 0 0 0 0 " _._ ____ _. _r., _. .0 _ __ 16X19-30ad___ 76. 8i - _. _ _ . __0.032. c.._. _ 1.25 _ '.0.62 .. _182 _.__ _ -_.- _182 . 227_____113 ... _.182 ___„182 __..,.__227 _ _.__ 113 C C partceilinu. - - -- 0.033.�_ . 0.00._ .-v0.00 --- 0 - 0 _ 0 .. -0 - -- 0 -- -_.__0 _- 0. ._ - 0 F.._ -19A-30bswp,.__ __:_...._ ____ 0.034 _---___--0.00. ___0.00. _ 0 0 _ _ 0._ _ 0 _---- _0 --�_-0 ___ ._. _Q ._._ A F___.I9A-30bswP___--- -0.034 0.00 -- 0`00 -- - _4-- - 0 0 - 0 0 0 -___0 - .0 61 c)AED excursion 1121 1 1 1 279 Envelope loss/gain 1624 1289 1 1 1624 1557 12 a) Infiltration 179 30 179 30 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 2100 2100 Subtotal(lines 6 to 13) 1803 3880 1803 4147 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1803 3880 1803 4147 15 Dud loads 0% 0% 0 0 0% 0% 0 0 Total L I 803 Air required I(cfm) I I I oad 1200I 31180 147 200I I I 12001 803 4214 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -f#+-wrtg0it�soYta 2026-Feb-2514:46:39 Right-Suite@ Universal 2025 25.0.04 RSU54447 Page Old Farm ResidenceA20 Old Farm Residence.rup Calc=MJ8 Front Door faces: N -+ wrightsoft° Right-JO Worksheet Job: 420 Old Farm Res. FCU 5 Date: February 19,2026 By: FR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com 1 Room name FCU 5 MSI4 2 Exposed wall 21.0 ft 21.0 ft 3 Room height 9.0 ft 9.0 ft 4 Room dimensions 5 Room area 107.0 ft' 107.0 ft' Ty Construction U-value Or I HTM I Area (ft') Load I Area (ft') Load number (Btuh/ft-°F (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V►1 12F-4sw 0.053 n 3.07 0.94 ' 90 90 277 -'-84 --90 -'- 90 277 4-1 D-c2ow 0.570 ._n 0.00 0.00 _-0 _ -0 _ 0--_- -0 0 - 0 0 0 VI/ 12F-4sw 0.053 a 0.00 0.00 0 0 0 0 0 0 0 0 _ 1 D-c2o.w _ _ _ - 0.570 e__. - 0.00 __-0,00_---___-0_ ___0_ -. .- -0 11 12F-4sw 0.053 s 0.00 0.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 s 0.00 0.00 0 0 0 0 0 01. 0 0 11D0_____ _ 0,3911 s _ _ 0.00-._. .0,00 _ _. _0 0 _ _ _ _0 _0 0 0 _ _ _0 0. V)/ 12F-4sw 0.053 w 3.07 0.94 99 77 238 73 99 77 238 73 L_G 1D-c2ow 0.570 w 33.06 62.85 22 0 716 1362 22 0 716 1362 ...... 11DO _ 0.390 w 0.00 0.00 0 0 0 0 0 0 0 `0 -C_ -16X19-30ad_ __ _ _ 0.032 _ _.. 1.25- _ _0.62 _-107 107 -_ ___134 _ 66 _ __107- _. _107 _. __ 134_ _ _. 66 C _ Cpartceilinq•__ _ ,_ 0.033 _ _ _ 0.00 0.00 -_ -__ 0 __ 0 _ -0 0 _ F. .___ 19A-30bswp. _--_.__ 0.034 _____1.65 _. _ 0.51 _. _ --4 ....__4_._ .. _7 ____.2 _- _ 4 ._„_ _ _4 ___- 7_ - ._ -2 F_ 19A-30bswp_ _ 0.034 _- 0.00 _0.00 __.. _--__0 0 _ --.u._.0 __t 6 c)AED excursion 1 661 1 767 Envelope loss/gain 1371 2249 1 1 1371 2354 12 a) Infiltration 139 24 139 24 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 2100 2100 Subtotal(lines 6 to 13) 1510 4832 1510 4938 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1510 4832 1510 4938 15 Dud loads 0% 0% 0 0 0% 0% 0 0 Total room load 1510I 4832 I 1 1510 49311 Air required(dm) 200 200 200 204 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -i#+-wrlgl�Lsaft'��� ^�•^-• •••�-••-•- Right-Suite®Universal 2025 25.0.04 RSU54447 2026-Feb-2514:46:39Page 10 Old Farm Residence1420 Old Farm Residence.rup Calc=MJB Front Door faces: N wrightsoft Right-M Worksheet Job: 420 Old Farm Res. FCU P Date: February 19,2026 By: FIR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com 1 Room name FCU 6 ZONE#1 2 Exposed wall 138.0 ft 138.0 ft 3 Room height 9.0 ft 9.0 ft heat/cool 4 Room dimensions 1.0 x 970.0 ft 5 Room area 970.0 ft' 970.0 ft' Ty Construction U-value Or HTM Area (ft°) Load Area (ft�) Load number (Btuh/ft2- I (Btuh/ft') I or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool -- 1--: 0 -- - - -- -- _-- - --- -- --- - - -- - ---- - - 6 V)! 12F�sw � .053 n 3.07 0.94 63 63 194 59 63 63 194 59 1D_c2ow_ ._ _ -- _ -- ----- 0.570._ n.. _. _-0.00. _0.00 - _0'. ---- -0 _ ___0 _ ------ _..___0 - .- __-_0. "_____0 0 V+/ 12F-4sw 0.053 a 3.07 0.94 432 412 1266 386 432 412 1266 386 C 1D_c2ow _ 0.570 a 33.06 -,.• 62.85 20 _ -._0 661 1257 20 0 -__661 ___1257 11 12F-4sw 0.053 s 3.07 0.94 279 247 759 232 279. 247 759 232 1D-c2ow 0.570 s 33.06 34.51 11 0 364 380 11 0 364 380 _ ._s. _._22.62 _,12.28.._ _._ 21 _..__ __21 _ -__475 _ .:_. 258 -.__ 21 ._._ .__21 __ _475 258 12F-4sw 0.053 w 3.07 0.94 468 356 1095 334 468 356 1095 334 1 D-c2ow 0.570 w 33.06 62.85 93 0 3075 5845 93 0 3075 5845 11D0 0.390 w 22.62 12.28 19 19 - 422 229 19 19 422 229 C_ .� 16X19-30ad._---___ ____.0.032 __-. _0.00 0.00 _-- -0.___---A _.__ _._-A_- --_-- _0 0-.-- --___0_- - Q _-- __0 .0 -_-_ Cpartceilinq,__ _. _•__•_____.0.033 ___ _ 1.94 _ __2.20 824 _824 95 15 ---_ 1815- _824 -824-...._1595 1815 F-- _..19A-30bswp --- - __0.034 - - 0.00 �_ 0.00 --0 ----0 ---------0 -- ---0 -- 0 ---0 --0 - -0, F__ - 19A-30bswp-_-_� 0.034„-_.- _____1-;65 ____0.51,_�.__970 - 970 1605 498. -_-_•__970___.- _970 1605 -_498 61 c)AED excursion 1 1 19471 1 1 1 1947 Envelope loss/gain 1 11512 13241 1 1 11512 13241 12 a) Infiltration 913 155 913 155 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 6 1380 Appliances/other 8800 8800 Subtotal(lines 6 to 13) 12425 23575 12425 23575 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 12425 23575 12425 23575 15 Dud loads 0% 0% 0 0 -0% 0% 0 0 Tot I room 35751 Air aequr dl(dm) I oad 11200I 24251 21200I I 35751 11200I 24251 21200I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -t wrig?�Ysof rz® 2026-Feb-25 14:46:39 Right-Suite®Universal2025 25.0.04 RSU54447 Page 11 Old Farm Residence\420 Old Farm Residence.rup Calc=MJ8 Front Door faces: N N p7- FIRST FLOOR ZC VE#1 ZON ZONE#3 Job#:420 Old Farm Res. Kolb Mechanical Scale: 1 : 115 Performed by FR for: Page 1 420 Old Farm Residence 11500 Old Sound Ave. Right-Suite@ Universal 2025 420 Old Farm Road Mattituck,NY 11952 25.0.04 RSU54447 -Orient,NY 11957 Phone:(631)298-5527 2026-Feb-25 14:47:28 info@kolbmechanical.com ...ence\420 Old Farm Residence.rup 1 s N F7- SECOND FLOOR ZONE#4 ZONE#7 ® z 1. ® z ZONE#5 ZONE#6 Job#: 420 Old Farm Res. Kolb Mechanical Scale: 1 : 115 Performed by FR for: Page 2 420 Old Farm Residence 11500 Old Sound Ave. Right-Suite@ Universal 2025 420 Old Farm Road Mattituck,NY 11952 25.0.04 RSU54447 Orient,NY 11957 Phone:(631)298-5527 2026-Feb-25 14:47:28 info@kolbmechanical.com ...ence\420 Old Farm Residence.rup Duct System Summary Job: 420 Old Farm Res. W�`IQE1tSC1ff' Date: February 19,2026 FCU 1 By: FR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Project • • For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0.70 in H2O 0.70 in H2O Available static pressure 0.30 in H2O 0.30 in H2O Supply/return available pressure 0.151 /0.149 in H2O 0.151 /0.149 in H2O Lowest friction rate 0.080 in/100ft 0.080 in/100ft Actual air flow 600 cfm 600 cfm Total effective length (TEL) 383 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln (ft) Ln (ft) Trunk ZONE#2 h 1317 77 70 0.080 7.0 Ox 0 VIFx 9.0 95.0 ZONE#2-A h 1317 77 70 0.080 7.0 Ox0 VIFx 10.0 180.0 st3 ZONE#2-B h 1317 77 70 0.080 7.0 Ox0 VIFx 24.0 105.0 st3 ZONE#2-C h 1317 77 70 0.080 7.0 Ox0 VIFx 15.0 170.0 st3 ZONE#3 c 2660 98 106 0.080 7.0 Ox 0 VIFx 23.0 170.0 st2 ZONE#3-A c 2660 98 106 0.080 7.0 Ox 0 VIFx 30.0 160.0 st2 ZONE#3-B c 2660 98 106 0.080 7.0 Ox 0 VIFx 25.0 160.0 st2 SupplyTrunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (Cfm) FIR (fpm) (in) (in) Material Trunk st2 Peak AVF 293 319 0.080 574 9.4 8 x 10 ShtMetl st3 Peak AVF 230 211 0.080 518 8.3 8 x 8 ShtMetl Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox 0 328 317 190.0 0.078 417 12.0 Ox 0 VIFx rb2 Ox 0 272 283 90.0 0.080 519 10.0 Ox 0 VIFx Bold/italic values have been manually overridden -h- wrightsofe^ 2026-Feb-2514:46:40 Right-Suite®Universal 2025 25.0.04 RSU54447 Page 1 +� ...Old Farm Residencel420 Old Farm Residence sup Calc=MJ8 Front Door faces: N Duct System® Summary Job: 420 Old Farm Res. - - wrightsoft Date: February 19,2026 FCU 2 By: FR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Project Information For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Heating Cooling External static pressure 0 in H2O 0 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0 in H2O 0 in H2O Supply/return available pressure 0.000/0.000 in H2O 0.000/0.000 in H2O Lowest friction rate 0 in/100ft 0 in/100ft Actual air flow 400 cfm 400 cfm Total effective length (TEL) 0 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk ZONE#4 c 9633 400 412 0 0 Ox 0 ShMt 0 0 TableReturn Branch Detail Grille Htg Cig TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) . FR (fpm) (in) (in) Opening (in) Matl Trunk rb4 Ox 0 400 412 0 0 0 0 Ox 0 ShMt wrightsoft^ 2026-Feb-2514:46:40 ^► .,.,.,.,_,...,.d._,.�..., Right-Suite®Universal 2025 25.0.04 RSU54447 Page 2 �+� ...Old Farm Residence\420 Old Farm Residence.rup Calc=MJ8 Front Door faces: N Job: 420 Old Farm +�- wrightsoft9 Duct System Summary Date: February 19,2Roz6 FCU 3 By: FR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Project • • For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Heating Cooling External static pressure 0 in H2O 0 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0 in H2O 0 in H2O Supply/return available pressure 0.000/0.000 in H2O 0.000/0.000 in H2O Lowest friction rate 0 in/100ft 0 in/100ft Actual air flow 300 cfm 300 cfm Total effective length(TEL) 0 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk ZONE#5 c 5946 300 326 0 0 Ox 0 ShMt 0 0 TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb5 Ox 0 300 326 0 0 0 0 Ox 0 ShMt L -Fk wrigh=of - 2026-Feb-2514:46:40 Right-Suite®Universal 2025 25.0.04 RSU54447 Page 3 ...Old Farm Residence1420 Old Farm Residence.rup calc=MJ8 Front Door faces: N �• Duct System Summary Job: 420 Old Farm Res. 1N1`lght$Ot 1,° Date: February 19,2026 FCU 4 By: FR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Project • • For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Heating Cooling External static pressure 0 in H2O 0 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0 in H2O 0 in H2O Supply/return available pressure 0.000/0.000 in H2O 0.000/0.000 in H2O Lowest friction rate 0 in/100ft 0 in/100ft Actual air flow 200 cfm 200 cfm Total effective length (TEL) 0 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk ZONE#6-A c 4147 200 214 0 0 Ox 0 ShMt 0 0 Table - Return Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Mat[ Trunk rb6 Ox 0 200 214 0 0 0 0 Ox 0 ShMt eF WrigrIL5O 2026 Feb 25 14:46:40 ,�.•.. Right-Suite®Universal 202525.0.04RSU54447 Page Old Farm Residence\420 Old Farm Residence.rup Calc=MJ8 Front Door faces: N Duct System Summary Job: 420 Old Farm Res. wrightsQft Date: February 19,2026 FCU 5 By: FR Kolb Mechanical 11500 Old Sound Ave.,Mattituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Project • • For: 420 Old Farm Residence 420 Old Farm Road, Orient, NY 11957 Heating Cooling External static pressure 0 in H2O 0 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0 in H2O 0 in H2O Supply/return available pressure 0.000/0.000 in H2O 0.000/0.000 in H2O Lowest friction rate 0 in/100ft 0 in/100ft Actual air flow 200 cfm 200 cfm Total effective length (TEL) 0 ft SupplyDetail Table Design Htg Cig Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk ZONE#7-A c 4938 200 204 0 0 Ox 0 ShMt 0 0 BranchReturn Table Grille Htg Cig TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb7 Ox 0 200 204 0 0 0 0 Ox 0 ShMt L 414- Wright raft- 2026-Feb-2514:46:40 Zt ..._, Right-Suitee Universal 2025 25.0.04 RSU54447 Page ...Old Farm Residence\420 Old Farm Residence.rup Calc=MJ8 Front Door faces: N e Duct System Summary Job: 420 Old Farm Res. 1�1/1`ight$o1 a Date: February 19,2026 FCU 6 By: FR Kolb Mechanical 11500 Old Sound Ave.,Maftituck,NY 11952 Phone:(631)298-5527 Email:info@kolbmechanical.com Project • • For: 420 Old Farm Residence 420 Old Farm Road,Orient, NY 11957 Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0.70 in H2O 0.70 in H2O Available static pressure 0.30 in H2O 0.30 in H2O Supply/return available pressure 0.236/0.064 in H2O 0.236/0.064 in H2O Lowest friction rate 0.080 in/100ft 0.080 in/100ft Actual air flow 1200 cfm 1200 cfm Total effective length(TEL) 295 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk ZONE#1 c 1381 133 133 0.080 8.0 Ox 0 VIFx 15.0 205.0 st1 ZONE#1-A c 1381 133 133 0.080 8.0 Ox 0 VIFx 21.0 205.0 st1 ZONE#1-B c 1381 133 133 0.080 8.0 Ox0 VIFx 27.0 190.0 st1 ZONE#1-C c 1381 133 133 0.080 8.0 Ox0 VIFx 37.0 170.0 st1 ZONE#1-D C 1381 133 133 0.080 8.0 Ox0 VIFx 49.0 105.0 st1 ZONE#1-E c 1381 133 133 0.080 8.0 Ox0 VIFx 27.0 205.0 st1 ZONE#1-F C 1381 133 133 0.080 8.0 Ox0 VIFx 24.0 205.0 st1 ZONE#1-G C 1381 133 133 0.080 8.0 Ox 0 VIFx 32.0 180.0 st1 ZONE#1-H C 1381 133 133 0.080 8.0 Ox0 VIFx 30.0 195.0 st1 Supply Trunk Detail • Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (Cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 1200 1200 0.080 771 15.4 8 x 28 ShtMetl TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb3 Ox 0 1200 1200 63.0 0.080 679 18.0 Ox 0 VIFx Bold/italic values have been manually overridden wr.iglhtsofr 2026-Feb-25 14:46:40 t •.u.r, w w v<s.�. Right-Suite@ Universal 2025 25.0.04 RSU54447 Page 6 Old Farm Residence\420 Old Farm Residence sup Calc=MJB Front Door faces: N FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) �`� O(� OQ� ------------------------------------ O Zc FOUNDATION (2ND) ROUGH FRAMING& PLUMBING CN^ ;1 INSULATION PER N.Y. �-- STATE ENERGY CODE O UI FINAL ADDITIONAL COMMENTS C C - S-elliAgoA- �t- `1W 1 V.206 -3-15 Ce r-+, �- 2- 27- 26 rKarnc c'EJ rcc' -lk ro z �p x sz�� x od Jb ' o��g�Ff01KCOG TOWN OF SOUTHOLD-BUILDING DEPARTMENT h x Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 oy o�A Telephone(631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only E � Q V E PERMIT NO. y U Building Inspector: 9 4 MQY 8 2024 i; tn•. ,a Applications and forms must.be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. .;M�:>z ry%' '^'•'�'"- 't`° i Date: OWNER(S)OF PROPERTY: SCTM# 1000 5�GZ- �' a Name: �_ocn � ►._2��.._G._.�_G-...---_... . �-_��G� � �_r. ._ Project Address: Phone#: G �, � -�� Email: G �(/•1 U/X4 0 6-4WA/- •Cf G�'1 Mailing Address: Gtl-17�.O- S? Ncu% K. P_Y 'CONTACT PERSON: Name: i_V/of? Mailing Address: 100� -D/r p pZ 1C1<f... .414-f) -O Az46,Afr..- P Y - (r9 f7. . Phone#: �0 6 _ rL 6.. .. Email:.'_ DESIGN PROFESSIONAL INFORMATION: Name: f� GC?, C�► �7'�Gr.f G-{fA/� G£ -4-4�,4/TrCTUtC rU-4. Mailing Address. 3 $0WiPtY f P. O. fak i-O T mow..�o6ae.-- __ ..o.v 2 .._ _ _-___.._.___ _-_._-_-___. �___ Gk...._. Phone#- o P����►Zt i as - - -- (7- G��-� 'Z33` �� 1v EmailD� 0114 CONTRACTOR INFORMATION: Name:...� 5________ _U_(__Nf�_ Mailing Address: �� �� Phone#: 4o�� ( / �U _7 Email: DESCRIPTION OF PROPOSED'CONSTRUCTION ew Structure ❑Addition ❑Alteration ❑Repair El Demolition Estimated Cost of Project: ❑Other $ Will the lot be re-graded? ❑Yes No Will excess fill be removed from premises? es ❑No 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ENO IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the.Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By( int name):W ��.lD ❑Authorized Agent ❑Owner Signature of Applicant: Date: CONNIE"13.-BUNCH. .. ... ..... . .. .. _ _ ._ Notary Public,State of New York STATE OF NEW YORK) No.01BU6186050 SS: Quallfled in Suffolk County COUNTY OF ) Ccinmi'eslon BxplroeApril 14,2 0�;Lb' `t �S VV��y� h.�I being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the 0AG (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. i Sworn before me this O day of 20c,1 Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 ARTIVIENT- Electrical Inspector WN OF SOUTHOLD 1` 21 '` '\ Town Hall And - 54375 Main Road - PO Box 1179 JUL 1 2 202QSouthold, New York 11971-0959 4*J ,�o�. Telephone (631) 765-1802 - FAX (631) 765-9502 1 :{ I oldtownny.goy — seand(aD-southoldtownny.gov T® .)F SOUM01 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INF RMATION (AII Information Required) Date: Z Company Name: Electrician's Name: ;� _ — ��p` W License No.: Z Elec. email: Elec. Phone No: / ?6 2 (,c3 [Al request an email copy of Certificate of Compliance Elec. Address.: d BC / k '—� JOB SITE INFORMATION (All Information Required) Name: Zd Q ltm Eo),ntb L- G Address: C,/ w\� Zo Cross Street: Phone No.: 3 J 76 d<j Bldg.Permit#: 5---0 email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YESt2�10 ❑Rough In ❑ Final Do you need a Temp Certificate?: YES ❑ NO Issued On 9 Z 7a p Temp Information: (All information required) Service Size P1 Ph❑3 Ph Size:�20-0 A # Meters Old Meter# ❑New Service❑Fire ReconnectE]Flocyd Reconnect❑Service Reconnect Underground❑Overhead # Underground Laterals 1 2Flj/H Frame Pole Work done on Service? Y FIN Additional Information: le 0 . PAYMENT DUE WITH APPLICATION fiZ l .�-71Iz'2y �OS��FQI�:CO BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD� o t Town Hall Annex-54375 Main Road - PO Box 1179 o _ Southold. New York 11971-0959 'jfj0 ao� Telephone (631) 765-1802 - FAX(631) 765-9502 ja mesh(cb_southoldtownny.gov - sea nd(c�southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 8/14/2024 Company Name: REP Electric LLC Electrician's Name: Robert E Paladino License No.: 46288ME Elec. email:REPelectric1@gmail.com Elec. Phone No: 631-767-6034 01 request an email copy of Certificate of Compliance Elec. Address.: PO Box 635 Mattituck, NY 11952 JOB SITE INFORMATION (All Information Required) Name: 420 Old Farm Rd LLC Address: 420 Old Farm Rd Orient Cross Street: Phone No.: 646-261-5045 Bldg.Permit#: 50888 email:Iwestvind@gmail.com Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): 200 AMP underground service Square Footage: Circle All That Apply: Is job ready for inspection?: ❑� YES ❑NO ❑Rou h n I ' ad Do you need a Temp Certificate?: YES `/ NO IssBe�d4n LE y ❑ ❑ Temp Information: (All information required) Service SizeFv-11 Ph 03 Ph Size: 200 A #Meters 1 Old Meter# O✓ New ServiceO Fire ReconnectO Flood ReconnectOService Reconnect anderground DOverhead #Underground Laterals 1 ✓2 ✓ H Frame Pole Work done on Service? Y ✓N Additional Information: PAYMENT DUE WITH APPLICATION a Ike C- 10$ I -7 (o bP 888 Og�FFDtlr BUILDING DEPARTMENT-Electrical Inspector o TOWN OF SOUTHOLD Town Hall Annex-54375 Main Road-PO Box 1179-Southold NY 11971-0959 Telephone 631 765-1802 , Temporary Certificate # 1-7Z- Date ' / Z 2024 Customer Name 420 oLd f �tm bad L(C, Electrician Name dll�Er0 G Address ZLO O rrl� D,e(jjt Phone 3 _ 6 7 001 e-mail a-mail (.;rma-A aw, Phone License# eg H6� Size___gjQ(Z_A Phase�_Overhead Underground #of Meters Remarks #of Underground Laterals 1 2 New "H" Frame or Pole H P Fire Reconnect Was work done on Service? Y/N Flood Reconnect Old Meter# Service Reconnected Application for electrical service equipment is on file with the town of Southold.On the applicant's notification that this installation is complete,the town will conduct a premises inspection of the service equipment. This verification is valid for 90 dawiftorn above. Authorized by ` .-2 NOV 4 11�rl BUILDING DEPARTMENT- Electrical Inspector 2024 TOWN OF SOUTHOLD 1 40 Town Hall Annex- 54375 Main Road -rzP,0. Box 117.9 Southold, New York 11971-0959 4,, Telephone (631) 765-1802 - FAX (631) 765-9502 La mesh CcD-southol dtown ny.gov- seand[c@-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFPP Date: ,,�AATION (All information Required) -3 Company Name: Electrician's Name: p v License No.: ,n r Elec. email: Elec. Phone No: Z6a request an email copy of Certificate of Compliance Elec. Address.: PO JOB SITE INFORMATION (All Information Required) 4k Name- �Cl Address- f2 0 a k Cross Street: Phone No.: (S31 4�503 Bldg.Permit#: 5 o 2:�-e ey email: 1 Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES 1Q& F-1 Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ff NO issued On Temp, Information: (All information required) Service SizeF-11 PhF-]3 Ph Size: A # Meters Old Meterft ❑New ServiceF Fire Reconnect[]Flood Reconnect Dservice Reconnect OUnderground E]Overhead # Underground Laterals[-]1 F-]2 F-] H Frame [] Pole Work done on Service? M Y E]N Additional Information: PAYMENT DUE WITH APPLICATION PERMIT# Address: C_7D Fpr&ft-A go Switches 0 Outlets 7 7 GFI's Surface Sconces q H H's UC Lts p `-e Fridge HW" f POOL Fans Mini Fr. W/D Panel Pump Exhaust 4-/ Oven Sump Heater P Trnsf r Smokes DW Generator Salt Ge . I Carbon Micro P. GrbDis Water Bond 1 e SS<djQ9 6°AJ Lights Heat I Pucks ERV CCJ�lz - S w �c HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH 3 Hood I Blower Service Amps ;?-o o Have&6 Used /-ll,�• Sub Amps/ w Have Used S Comments W74' C1/-77-- CC M )90_q ���m� k- a ktq t# � Scott A. Russell J.°sUFFQ,a STOaKI��I WA\TJE K SUPERVISOR N MAN IEMIENT SOUTHOLD TOWN HALL-P.O.Box 1179 O Town of Southold 53095 Main Road-SOUTHOLD,NEW YORK 11971 CHAPTER 236 - STORMWATER MANAGEMENT REFERRAL FORM ( APPLICANT INFORMATION TO BE COMPLETED BY THE APPLICANT ONLY FOR PROPERTIES ONE ACRE IN AREA OR LARGER. ) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - APPLICANT: (Property Owner, Design Professional, Agent, Contractor, Other) NAME: AkPU A V p Date: 6��63�2�tq n, � Y,- SjgVtnei Contact Information: 45� #&" _ lE-Mail B Telephone Numbed / �)ny� ,A� w (F) I fo Af Property Address / Location of Construction Site: G .p E*4pA /2pt4P S.C.T.M. #: 1000 O r— I E� YJ v /( �� 7 District Section Block Lot TO BE COMPLETED BY SOUTHOLD TOWN ENGINEERING DEPARTMENT - - - - - - - - - - - - - - - - - - - - - - - - - - - _ _ _ - - - - - Area of Disturbance is less than 1 Acre. No S.P.D.E.S. Permit is Required ! Project does Not Discharge to Waters of the State. No S.P.D,E.S. Permit is Required ! - Area of Disturbance is Greater than 1 Aare &Storm-water Runoff Discharges Directly to Waters of the State of New York. THE APPLICANT MUST OBTAIN a S.P.D.E.S. Permit DIRECTLY From N.Y.S. D.E.C. Prior to Issuance of a Building Permit. - Area of Disturbance is Greater than 1 Acre &Storm-water Runoff Flows Through Southold Town's MS4 Systems to Waters of the State of New York. THE APPLICANT MUST OBTAIN a S.P.D.E.S. Permit through the Southold Town Engineering Department Prior to Issuance of a Building Permit. Reviewed By: Date: Jq /;?L-/ r nRM x CM(-P-Tnq nrtnha,-7(1 i ci C c x/ g yve 4.20 OLD FARM ROAD !I _S�2,32'3�„� ORIENT,NY 11957 cn ! _f>>•98� CID of � � m II I TRUE NORTH CD I x S IN ! sso42/;,0 i 20 ! 0 00, TAX MAP NO.1000-25:" I H ISSUE/REVISION DATE I .! .00 ADDITIONAL MATERIAL 07.15.2024 I I DRAWN BY:1.LACHAPELLE I CHECKED BY:J.LACHAPELLE X NOTE:THIS IS AN 11"z 17"SHEET DRAWINGS MAY BE PRINTED NOT TO SCALE j SCTM#1000-25.-5-8 / ' CO LaChapelle Architecture PLLC P.O.Box 1251 Mattituck,NY 11952 (646)251-5058 jake@lachapellearchitecture.com Cr rry RED ARC i �LACHgA /jam I 0 /! 03;i9SID�yQ N E OF X t�1 o" n-1----� 4 ,nrsnw,Xc,s nX ms3nurcn smeuenXo ,Xe rXarcX„"f u[X,u,ue 0 �[XX cnX rc, �XX� rcrs,XE, nrs r .E�XXEaG,X„rc"nwX..,n,Xm"[XSEOX o EXenX�s�rcmX�Xa,e� , � 01"CX enXii[s.WI,XOY[iXE WHRI[x CONSLX,Of 4CNSP¢4Eaa[mlEt,up[fL4 ti XneEiaE nvc"rccc,uaefuc „ 226.40' S 85 25 00 w SITE PLAN ROAD LOT,CORNER n OLD FARM A lot situated at the junction of and fronting on two or more streets.A lot abutting a curved street shall be deemed a"corner lot"if the tangents to the curve at the points of intersection of the side lot lines with the street SHEET NO: SURVEY AND DIMENSIONAL DATA IS OBTAINED lines intersect at an interior angle of less than 135°. NORTH OSITE PLAN FROM SURVEY BY KENNETH M WOYCHUK LAND SCALE: 1/32" = T-0` SURVEYING,PLLC DATED 3/2712024. [Amended 6-29-2021 by L.L.No.9-2021] SHEET 1 OF 1 S.C.T.M.# DISTRICT 1000 SECTION 25 BLOCK 5 LOT 8 #R-21 -0769 SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES Water lines Must beinse±ctedbvthe PERMIT FOR APPROVAL OF CONSTRUCTION FOR A Svffolktount _!.oitiealth_s•rvices_, SINGLE FAMILY RESIDENCE O LY Call(631)852-5754,48 hours in advance,to schedule ins;aeetion(s). WELL AND LATERAL MUST BE DATE 5/6/21 HAS. Rpp. NO. R-21-0769 SHOWN ON FINAL SURVEY APPROVED �' FOR MAXIMUM OF 5 BEDROOMS EXPIRES THREE YEARS FROM DATE OF APPROVAL i Revised Plan Approved 4/9/24 / Expires 5/6/27 O 245 \ 125' WELL SEPTIC / / DWELLING \\ W/WELL WATER / � 180' S o 32 LOT 4 WELL 71 \\ �� SEPTICD ST 17 O• / ---' 171.981 DWELLING W/WELL WATER w° LOT 5 v, I o \\ S6So 5 BEDROOM SANITARY SYSTEM \\ 2'0 F 1500 GAL S.T. 17, (2)8'0x8'DEEP L.P. 150' E)CP MN 8'Ex5'DEEP �c� LP 'DRY\� O NCF'940 MIN i�A `WELLS CELLAR ENT. A N'0 V m z� EL(16.5) NF LP g EL(16.5) .... S.T. 7.7 c.oi :....:;:;:; f 0 Rcpos£p O ::::: : 0::::.:�. O ....... ...... y 10p00, / �00• / :.....:f 15.0 ....... \ /16,♦ o cfOo nW O n :: o \\ / LOT 7 �ii, \��� . .:.°m— `- vOa LOT 6 VACANT �i :::::. :::::. . . :.::::::.*i:: 200' � ::::PROPOSED .'•::•::•::•::•� ::`:::Q m b / i CL 14.7 DWELLING :SWIMMING POOL ; :;: ...•'•:�: : ::U c�i / /ti W/WELL WATER w Q u 0' I \ SEPTIC OVER 74.9 :34.6' / �O .............EL 16.0) EL(16.0) V) w---_ h OVERSIZE FOR POOL /• F. WASTE WATER o ~ / 15 Cb OQ• �\ ,/ � gyp• ,.74 1 CL 14.3 01 S85°25'00"W ------15--- ------- ---------------------- _14"— EDGE OF PAVEMENT _ � \;`--------- OLD FARM ROAD----13--_ CL 13.2 CL 13.4 CL 14.5 _`\��\ / / ®WELL DWELLING W/WELL WATER VACANT SO' 1 SEPTIC DWELLING O I WAVELL WATER / I O DWELLING I t WI/WELL WATER 1 WELL / I I DRAINAGE CALCULATION 20' I PROPOSED DWELLING W/COVERED PORCH: 2528 SQ.FT. \ 2528 x 0.166=419.6 < 420cf REQUIRED I sE '75 I (1) B'DIA x 5' DEEP ORYWELL=221cf PROVIDED _ f I (1) B'DIA x 7' DEEP DRYWELL=310cf PROVIDED 531 cf TOTAL ***OVERSIZED FOR POOL WASTE WATER ZONED R-80 THE WATER SUPPLY, WELLS, DRYWELLS AND CESSPOOL ELEV. 16.0 FRONT YARD: 60'MIN LOCA77ONS SHOWN ARE FROM FIELD OBSERVA77ONS SIDE YARD: 20' MIN, 45' TOTAL AND OR DATA OBTAINED FROM 07HERS. OL BOAM 0.5' REAR YARD: 75' MIN AREA: 60,697.73 SQ.FT. or 1.39 ACRES ELEVATION DATUM: NAVD88__-_V BROWN 2 0' UNAUTHORIZED AL7ERA7ION OR ADDITION TO THIS SURVEY IS A WOLA770AI OF SEC77ON 7209 OF THE NEW YORK STATE EDUCA77ON LAW. COPIES OF THIS SURVEY ML SANDY SILT MAP NOT BEARING THE LAND SURVEYOR'S EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THIE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE 717LE COMPANY, GOVERNMENTAL AGENCY AND LENDING INS717U77ON BROWN TYPICAL CLEAN OUT LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTITUTION, GUARANTEES ARE NOT TRANSFERABLE. FINE TO MED. THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM 771E PROPERTY LINES TO THE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE THEY ARE Sw SAND 12.0' SLATE OR NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE EREC77ON OF FENCES ADD177ONAL STRUCTURES OR AND OTHER IMPROVEMENTS EASEMENTS GRAVEL SUITABLE COVE OROPPE PLUG END AND/OR SUBSURFACE STRUCTURES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE TIME OF SURVEY 1001, SURVEY OF. LOT 6 of NC;.;, CERTIFIED TO: PARALLEL PROPERTIES, LLC; WATER WATER EL 1.5 MAP OF: BAYVIEW FARM P N M o Ia FIDELITY NATIONAL TITLE INSURANCE SERVICES, LLC; IN HIGHEST EXPECTED 2.0Sw k,� �► �' PALE BROWN FILED: BAN 19, 1982 No 7045 FINE TO MED. 30' ELBOW Y n SAND 60' WYE SITUATED AT: ORIENT - 17' TOWN OF: SOUTHOLD ` _ K. WOYCHUK Ls �� ,• KENNETH M WOYCHUK LAND SURVEYING, PLLC FEB. 28, 2021 FLOW REVISED 03-27-24 SUFFOLK COUNTY, NEW YORK ZSF 0;5 FF,,2 a Professional Land Surveying and Design REVISED 03-23-24 I P.O. Hog 153 Aquebogue, New York 11931 UPDATE 05-02-21 ENO' PHONE (631)298-1588 FAX (631) 298-1588 ALE #221- 13 SCALE: "=30' DATE: FEB. 28, 2021 N.Y.S. LISC'. N0. 050882 S.C.T.M.# DISTRICT 1000 SECTION 25 DLOCK 5 LOT 8 #R-21 -0769 0 m / \ \ SEPTIC WELL / DWELLING 1\\ W/WELL WATER S72o32'30 LOT 4 / �1180, �/ \ JWELL r ' OW SEPTICD O• `ll�r Z,T / v / DWELLING W VELL WATER w V2 i LOT 5 o I Tt1 5 BEDROOM SANITARY SYSTEM 1500 GAL S.T. i (2)8'0x8'DEEP L.P. `17`\N 150' EXP MN 8'0x5'DEEP 4'F 8' LP (DRY \1 p FNCF A Mi SWELL)w� CELLAR EINT. �ONc C/iyF LP g. EL(16.5) o EL(16.5) Miy ::::•24.8':�::::::: 9.5' v......::.. :::::::::: S.T. c.0. : `:;`:::>: :::: :::. ................ :::::;::in: pRCpOSFD Oo / ::::::::. .......... AY DO �. 15.0" W o :'''':16, LOT 7 �/ '\ �mw� oa VACANT /// �.. atl :: 13.6':.. I LOT 6 200' �/ ................. ::::::: ff W PROPOSED•::::::::.... •• :.'..Q c6 o SWIMMING POOL ' DWELLING i::(I:Y.i•i:•:U `- N \ ! / CL 14.7 /WELL 16 — 40'x16......:: :::::: ` ......N Q a / / /� W WATER 74.9 34.6' / /Cwee s 50,OVER -` EL 16.0) EL(16.0) I \ T OVERSIZED FOR POOL WASTE WATER / \ z / Q� cr 1 /' / t�� Q4 Qov 0016, i'14 CL 14.3 / rn gyp' .' I TEST --- ---- - -- - R;85' WELL ------ -- 226.40' 11 I — I ------- — � --- — I--� „ ------ __---------— / .- — EDGE OF PAVEMENT ----_— _ / �CL 13.2 T, FARM ➢ OAR---13--- - --- CL 14.5 \ / ®WELL DWELLING W/WELL WATER VACANT 50' I SEPTIC I 75- 1 I DWELLING I (. W/WELL WATER / I O \.J/� DW\EWNG W/WEL � WATER � I I WELL \ I I I Q I I 0' / I I DRAINAGE CALCULATION ` I PROPOSED DWELLING W/COVERED PORCH: 2528 SQ.FT. SElrnc 2528 x 0.166=419.6 < 420cf REQUIRED �- EPTI I (1) B'DIA x 5' DEEP DRYWELL=221cf PROVIDED 075' (1) 8'DIA x 7' DEEP DRYWELL=310cf PROVIDED 531 cf TOTAL `OVERSIZED FOR POOL WASTE WATER ZONED YARD: THE WATER SUPPLY, WELLS, DRYWELLS AND CESSPOOL EL BR N -80 FRONT YARD: 60'MIN LOCA77ONS SHOWN ARE FROM F7ELD OBSERVA77ONS OL LOAM 0.5' SIDE YARD: 210' MIN, 45' TOTAL REAR YARD: 75' MIN AND OR DATA OBTAINED FROM OTHERS _ BROWN AREA: 60,697.73 SQ.FT. or 1.39 ACRES ELEVA7101V DATUM: NA_VD_88 _ ___� ML S4NDY SILT 2'0 UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF THE NEW YORK _ _______ STATE EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYOR'S EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN BROWN TYPICAL CLEAN OUT ONLY TO THE PERSON FOR WHOM 774E SURVEY IS PREPARED AND ON HIS BEHALF TO THE 777LE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITUTION FINE TO MED. LISTED HEREON, ,AND TO THE ASSIGNEES OF THE LENDING INSTITUTION, GUARANTEES ARE NOT TRANSFERABLE. SW D 12.0 THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO THE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE 774EY ARE SLATE OR STOPPER END GROVEL SUITABLE COVE NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE ERECTION OF FENCES, A00177ONAL STRUCTURES OR AND 07HER IMPROVEMENTS EASEMENTS OR PLUG AND/OR SUBSURFACE STRUCTURES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE 77ME OF SURVEY SURVEY OF: LOT ,O F �� WATER WATER EL 1.5 w CERTIFIED TO: PARALLEL PROPERTIES, LLC; IN HIGHEST EXPECTED 2.0 MAP OF: BAYVIEW FARM PALE BROWN M, i �P �N ko� o� FIDELITY NATIONAL TITLE INSURANCE SERVICES, LLC; SW FINE TO MED. FILED: JAN 19, 1982 No 7045 CO 30' ELBOW .. r SAND �. ., . 60' WYE SITUATED AT: ORIENT K. WOYCHUK LS TOWN OR SOUTHIOLD � -�'- �' 0 o e^u PLLC FEB. 28, 2021 FLOW REVISED 03-27-24 KENNETH M WOYCHUK LAND SURVEYING, -..- SUFFOLK COUf�JTY, NEW YORK ti � • 1F 05OF82 �� Professions and Surveying and Design REVISED 03-23-24 I p P.O. Box 153 Aquebogue, New York 11931 UPDATE 05-02-21 FILE N 221-13 SCALE;1"=30' DATE: FEB. 28, 2021 y PHONE (631)298-1588 FAX (631) 298-1588 N.Y.S. L/SC. NO.' 050882 S.C.T.M.# DISTRICT 1000 SECTION 25 BLOCK 5 LOT 8 #R-21-0769 �— �O 125' BELL I SEPTIC DWELLING s1x WAIELL WATER l• LOT 4 / WELL O SEPTIC I '"` LOT s g L` s6S 4 7� a1D' I a BEDROOM SWRARY SYSTEM F }� 15W GAL ST. 40b/s �` _'r-E' (2)8'he'DEEP LP. / 150' EXP A v wbebEf2P - y EP yEl CELLAR ENT. Lp e, EL(16.5 E1L10.3) bTx 00, SIX % / 0 wJLL '' ••oa ' LOT 7 �� :;.;aP ..136'.. LOT a 1 i VIVANT ........ ...:..:.�x DWELLING 2011 PROPOSED::::i:. .:: '`'rc m / SWIMMING P06L" .': ¢¢¢¢ / LT.tA7 /w gp.�wFR 74.9' .. 16.0) EL(16.0) It \ / OYOL�FOR E0a 20'0/s' to'o/s 1 WASTE, TER % I / / N 14 1 / a /1 14.3 / I------\-- —'---- — _R-ss p0 N — --- ---- -- — / ----- WELL ---------- - 226.40' It SIX -- ---- _ — — sss'2V00^w --__------ / E90E OF PMVE11LY1T �-�� FARM RIO�rD--+3 -- -- _ OLDCL 114 CL 14.3 / OWE/ elmw/1rELL WLUL.WATER Tm _ VIVAIDINT BIT SEP„C i { O � W�w m O wwTm I I I \ I I I I DRAINAGE CALCULATION • I I PROPOSED DWELIJNG W/COVERED PORCH: 2528 SQ.FT. WELL \ I I COVERED REAR DECK: 264 S.F. 2792 x 0,166-463.5 < 464cf REQUIRED (1) B'DIA x 5' DEEP DRYWELL-221cf PROVIDED -� 073 I (1) 8'DIA x 7'DEEP DRYWELL-310cf PROVIDED 531cf TOTAL *--OVERSIZED FOR POOL WASTE WATER ZONED R-80 THE WATER SUPPLY, WELLS;DRYWELLS AND CESSPOOL ELEV. 16.0 FRONT YARD: 60'MIN LOCAROVS SHOWN ARE FROM FIELD OBSERVA77OVS BROIRI SIDE YARD: 20" MIN, 45' TOTAL AND OR DATA OBTAINED FROM 07HERS. OL I 0.5' REAR YARD: 75' MIN — AREA:60,697.73 SO.FT. or 1.39 ACRES ELEVATION OARW. NAVD88 mm ML SANDY SILT 2.0' UNAUYHCR12ED AL VERA RON OR ADDITION 70 INS SURVEY IS A WO A77ON OF SEC7 /04 7209 OF THE NEW YORK STA 7E EDUCA 770M LAW. LOPES OF THIS SURVEY MAP NOT BEARING INE LAND SURVEYORS EMBOSSED SEAL SHALL NOT BE CONSIDERED 70 BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN ONLY 70 7H£PERSON FOR WHOM 7HE SURVEY IS PREPARED AND ON HIS BEHALF 70 THE 777LE COMPANY,GOVERNMENTAL AGENCY AND LENDING INS777U77OV BROWN TYPICAL CLEAN OUT LISTED HEREON,AND TO THE ASSIGNEES OF 7HE LENDING INSTI7U770V,GUARAN7EES ARE NOT TRANSFERABLE. FNE M�D. IIIE OFFSETS OR DNMFNSIONS SHOWN HEREON FROM THE PROPERTY LINES 70 THE S7RUC7URES ARE FOR A SPECW7C PURPOSE AND USE THEREFORE TWY ARE SW SWD 12.0' SLATE OR STOPPER END NOT INTENDED 7D MILNUMENT 7HE PROPERTY LINES OR TO GUIDE 7HE ERECTION OF FENCES AM77ONAL S7RUC7URES OR AND OTHER IMPROVEMENTS EASEMENTS GRAVEL& SUFFABLE COVER \ STOPPER PLUG '����FAICE SIRUC7URES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE TIME OF SURVEY SURVEY OF.LOT 6 OF NI,,, CERTIFIED TO: PARALLEL PROPERTIES, LLC; WATER WATER EL 1.5 t� M. + IN HIGHEST EXPECTED 2.0 MAP OF: BAYVIEVN FARM r�s� WDa y FlDELITY NATIONAL TREE INSURANCE SERVICES, LLC; SW PALE OWN RLED: JAN 19, '1982 No 7045 FK TO WLu 30' ELBOW SAND SITUATED AT:ORIEINT Y 60' WYE —17' TowH OF: SOUTHpLD ) K.WOYCENUK LS m L �� KENNETH M WOYCHUK LAND SURVEYING, PLLC FEB.28'2021 FLOWN" REVISED 03-27-24 SUFFOLK COUNI(Y, NEW YORK ?sF 030.6z �P Professional Land Surveying and Dealgn REVISED 03-23-24 f P.O. Box 153 Aquebogue, New York 11931 UPDATE 05-02-21 FILE f 221-13 SCALE:1'-30' DATE: FEB. 28. 2021 N.Y.S.LISC Na 050BB2 PEONS(e31)E9e-15aa FAX(631)228-10e15 pD. 9VE JUL 1 7 2024 E�e�Ftr^{n0' r?"Partment rmE�, Q Outsold S.C.T.M.# DISTRICT 1000 SECTION 25 BLOCK 5 LOT 8 #R-21 -0769 . d� C�� f� ��' / SEPTIC DWELLING STK. t\ W/WELL WATER 1180, LOT 4 / WELL 0 ow \�\ / /SEPTIC STK. 17 `SO• `-- - / 1 71.98, / DWELLING W/WELL WATER STK LOT 5 5 BEDROOM SANITARY SYSTEM 1500 GAL S.T. 4' (2)8'0x8'DEEP L.P. 17�"� j FCNCE 150' EXP Mry 8'+ex5'DE �O LP MIN �\� z (WE�l CELLAR ENT. i EL(16.5) EL(16.5) LPMN o 24.8' STK. 1,�--•`.' 20.1' p � S.T. 3 FOUNDATION N Ropo f o oR/ q y ?p0 pp O LOCATION 8-2-24 ^O TFND=18.0 1 / ao \ 16. (6 8.8, \\ / ' \\ I STK. to 1 � / LOT 7 �.' �� 13.6' I LOT 6 1 i VACANT �.' ::::::....:...:::.:::::: .ti:: 1 2 CAR I DWELLING 200' �� PROPOSED �, I i/ CL 14.7 W/WELL WATER .,.::SWIMMING POOL::: ♦ GARAGE N I SEPTIC OVER \ 16 \\ 34.7- \ 74.9 / %VVELL, 8'$x7'DEEP / tf) OVERSIZED FOR POOL WASTE WATER z p K it / / STK. Li 00/Q .4 161 14 1 N - STK. , I N - _ �� WEi sm. _ -- -----I -- 226.40 STK. S 85025'00"W ----15--- _ �_ _`-_- ------ ---------------- - ,, ------------��� - 4- EDGE OF PAVEMENT ��' / _---------- 'CL 13.2FARM OLDCL ,3.4 � CL 14.5 � / / WELL DWELLING ® 1- W/WELL WATER — I VACAM 50' ' SEPTIC75- 1 D -,�_4 0 AUG I W� TER -' I O BUILDWG DEPT. DWELLING ' T01VN.)r S©UTDOI — W/WELL WATER I DRAINAGE CALCULATION WELL I PROPOSED DWELLING W/COVERED PORCH: 2528 SQ.FT. WELL COVERED REAR DECK: 264 S.F. l�20' I 2792 x 0.166=463.5 < 464cf REQUIRED �- SEPTIC (1) B'DIA x 5' DEEP DRYWELL=221cf PROVIDED 075' I (1) 8'DIA x 7' DEEP DRYWELL=310cf PROVIDED 531cf TOTAL ELEV. 16.0 ***OVERSIZED FOR POOL WASTE WATER OL BLOAMROWN 0.5, BROWN TYPICAL CLEAN OUT ZONED R-80 THE WATER SUPPLY, WELLS, DRYWELLS AND CESSPOOL ML SANDY SILT 2.0 FRONT YAIRD: 60 MIN LOCA77ONS SHOWN ARE FROM FIELD OBSERVA77ONS SLATE OR SIDE YARD: 20' MIN, 45' TOTAL AND OR DATA OBTAINED FROM OTHERS. BROWN SUITABLE COVE STOPPER END REAR YARD: 75' MIN FINE TO MED. OR PLUG NAVD88 AREA: 60,697.73 SQ.FT. or 1.39 ACRES ELEVA170N DATUM: ___ _______________ SW SAND& 12.0' UNAUTHORIZED AL7ERA77ON OR ADDITION TO THIS SURVEY IS A WOLA77ON OF SECT70N 7209 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURVEY GRAVEL MAP NOT BEARING THE LAND SURVEYOR'S EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE TITLE COMPANY, GOVERNMENTAL AGENCY AND LENDING INS7777JTION LISTED HEREON, AND TO 774E ASSIGNEES OF THE LENDING INSTITUTION, GUARANTEES ARE NOT TRANSFERABLE. WATER WATER EL 1.5 43;0* ELBOW THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO THE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE 77.IEREFORE THEY ARE IN HIGHEST EXPECTED 2.0 60• W) NOT IN7E'NDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE ERECT70N OF FENCES, ADD177ONAL STRUCTURES OR AND 07HER IMPROVEMENTS. EASEMENTS SW PALE BROWN AND/OR SUBSURFACE STRUCTURES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON 774E PREMISES AT THE 77ME OF SURVEY FINE TO MED. SAND SURVEY OF: LOT 6 CERTIFIED TO: PARALLEL PROPERTIES, LLC; K. WOYCHUK LS 17� FLOW MAP OF: BAYVIEW FARM FIDELITY NATIONAL TITLE INSURANCE SERVICES, LLC; FEB. 28, 2021 FILED: JAN 19, 1982 No 7045 SITUATED AT: ORIENT FOUNDATION LOCATED 08-02-24 TOWN OF: SOUTHOLD KENNETH M WOYCHUK LAND SURVEYING, PLLC REVISED 03-27-24 SUFFOLK COUNTY, NEW YORK Professional Land Surveying and Design REVISED 03-23-24 �{ � / P.O. Box 153 Aquebogue, New York 11931 UPDATE 05-02-21 FILE p 221- 13 SCALE:1"=30' DATE: FEB. 28, 2021 C. N0. 050882 PHONE (831)298-1588 FAX (631) 298-1568 LIS S.C.T.M.# DISTRICT 1000 SECTION 25 BLOCK 5 LOT 8 #R-21 -0769 1O �W' / SEPTIC DWELLING STK. W/WELL WATER 180, 0.TE \\ LOT 4 / WELL O O j�O.TE �� <T/y S�2°32 1. 3pr,P d / 35 'xb SEPTIC\ / r171, \\ �-- STK. / 17 `- �� s POSrNviRFFSNCE 17T 98r W/WDWELLING ELL WATER cn LOT 5 STK. S 0 A B C �S s6,S3 S.T. 24' 64' \ 22pr L.P.1 22.5'79.5' 8'Ox8'DEEP X��\ L.P.2 43' 98' a LPz 17 WELL 100.5' 125' i �OOp 8'r17x8'DEEP 8'04'DEEP LP1 'DR1'\,L U f WELL, CELLAR EINT. EL(16.5) EL(16.5) o r:if:is 25.5'i::::':ii.: STK. rn A 20.1'': ::::.::::::.:::::.. v 1500 GAL. p „°Y v 2pp O S.T. :. .:::.:.::..::.::.:.:::.:.:..:.::...::::N i p O� ::•:2.STY.FRAME::::�:: :•::::::•::: T i :iiDWELLING#420,i:i:::i:Ciii:i:i: m 10.6' 15..0' ... : STK. i \ 0 �.'::::. .'::::::.'.':: 2ND FLR. _ �-_ PIPE! \ w o UNDERGROUND UTILITI _ OVER PORCH ELEC SDK. . / METER ....... i o / LOT 7 �i' t3.4':.. LOT I / VACANT �' RCA DRIVEWAY j / /DWELLING 200' ' l i� i:INGROUND:(•i:•:•:•i:Ci: '�:'io �O I / 14.7 W/W� WATER :i•i:POOL b??:?::•::•::::•i: w i:(i GARAGE::i.:N 9Q / /g� CL & SEPTIC OVER 3 �iL j /b 150, 16- 0 / F 66.8' :•..PAVER PATIO � B:((i•:i:i(•::(•35.2':•:(("}::•::C y GRAVEL j DRY 1 / \POOL x w k WELLi 8'$x7'DEEP %--" �EOP. 0 OVERSIZED FOR POOL WASTE WATER / 0 / 16 STK. 15 16 /114 � t CL 14.3 / / X 'N6'pOSTWIRE FENCE 10.4 --- STK WELL / _ 0.3'E X ------ 106N __X -X STK 226.40 1\ % STK. --- -15---- --- -- S 85025'00"W - ---- F PAVEMENT ---- 4_ -- EDGE 0 FARM -- OLD CL 13.4 / CL 14.5 ` � / / ®WELL DWELLING W/WELL WATER IVACANT 50' I SEPTIC � I o IDWELLINGI o ING W/WELf. WATER DWE W/WELL LLWATER I I I I I I WELL I WELL 4 r� ® ? 20, APR 3 I SEPTIC I I SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES APPROVAL OF CONSTRUCTED WORKS FOR ZONED R-80 THE WATER SUPPLY, WELLS, DRYWELLS AND CESSPOOL A SINGLE FAMILY RESIDENCE FRONT YARD: 60'MIN LOCA77ONS SHOWN ARE FROM FIELD OBSERVA77ONS 1 0 2026 " SIDE YARD: 20' MIN, 45' TOTAL AND OR DATA OBTAINED FROM OTHER APR S f. Igo. �' �� �7(09 REAR YARD: 75' MIN Date. H.S. i~ AREA: 60,697.73 SQ.FT. or 1.39 ACRES ELEVATION DAR1M: ___NAVD88 The seviave disposal and water surn!y far11 es at this location have been UNAUTHORIZED ALTERAT70N OR A00177ON TO 774IS SURVEY IS A WOLA77ON OF SECTION 7209 OF THE NEW YORK STATE EDUCA77ON LAW. COPIES OF THIS SURVEY inspected andf or certified by this I � .~i�::?n'.Or OthEr ag'CnciEs and MAP NOT BLEARING 7HE LAND SURVEYOR'S EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE 777LE COMPANY, GOVERNMENTAL AGENCY AND LENDING INS77TUT70N found to.be Sa IafOC.Or'y'i v r:tea^ I ,"I '�1 0= BEDROOMS. LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTITUTION, GUARANTEES ARE NOT TRANSFERABLE. THE OFFSET' OR DIMENSIONS SHOWN HEREON FROM 774E PROPERTY LINES TO THE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE 774EY ARE NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE EREC77ON OF FENCES, ADD177ONAL STRUCTURES OR AND OTHER IMPROVEMENTS. EASEMENTS AND/OR SUBSURFACE STRUCTURES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE TIME OF SURVEY JONATHAN PAI, P.E., CHIEF SURVEY OF: LOT 6 CERTIFIED TO: PARALLEL PROPERTIES, LLC; OFFICE OF kVASTE MANAGEMENT MAP OF: BIAYVIEW FARM FIDELITY NATIONAL TITLE INSURANCE SERVICES, LLC; FILED: JAN 19, 1982 No 7045 REVISED SANITARY 03-26-26 SITUATED AT:; ORIENT FINAL SURVEY 12-04-25 FOUNDATION LOCATED 08-02-24 TOWN OF: SOUTHOLD KENNETH M WOYCHUK LAND SURVEYING, PLLC REVISED 03-27-24 SUFFOLK COUNTY, NEW YORK Professional Land Surveying and Design REVISED 03-23-24 r P.O. Box 153 Aquebogue, New York 11931 UPDATE 05-02-21 FILE #221—13 SCALE:1 "=30' DATE: FEB. 28, 2021 C. N0. 050882 PHONE (631)298-1588 FAX (631) 298-1588 LIS CONSTRUCTION NOTES NAILING SCHEDULE STRAPPING DETAILS 4200LD FARM ROAD 1. ALL WORK SHALL CONFORM TO THE AF&PA WOOD FRAME 1. NAILING PER NYS CODE; INCLUDING (5)10d NAILS AT SILL AND 1. PROVIDE HURRICANE STRAPPING BY SIMPSON OR EQUAL ORIENT,NY 11957 CONSTRUCTION MANUAL 2015 HIGH WIND EDITION PLATE OF ALL 2x6 STUDS 2. PROVIDE (8) 8d COMMON NAILS IN EACH END OF 14" 20 GA, 2. DESIGN LOADS AS FOLLOWS: 2. USE GALVANIZED FASTENERS FOR ALL FRAMING GALVANIZED STRAP FOR LATERAL/SHEAR CONNECTIONS AT LIVE LOAD: PER TABLES R301.5 &R301.6 3. USE 6d NAILS @ 12" O.C. FOR EXTERIOR SHEATHING, EXCEPT USE RAFTER/ROOF-TO-WALL,WALL-TO-WALL,AND DEAD LOAD: PER R301.4 8d NAILS @ 4" O.C. FOR PERIMETER OF EACH SHEATHING SHEET WALL-TO-FOUNDATION CONNECTIONS IN CONFORMANCE w/ SNOW LOAD:20 PSF GROUND SNOW LOAD PER FIG. R301.2(6) TABLE 3.3b OF LATEST EDITION OF WOOD FRAME WIND EXPOSURE CATEGORY'C'FOR 130 MPH 3 SECOND GUST ROOF.FRAMING CONSTRUCTION MANUAL(WFCM) FOR 120 MPH FASTEST WIND PER R301.2.1.4&FIG. R301.2(5)A RAFTER TO TOP PLATE TOE-NAIL 3 PER RAFTER SPEED TRUE SEISMIC CATEGORY B PER FIGURE R301.2(2) CLG JOIST TO TOP PLACE TOE-NAIL 3 PER JOIST NORTH CLG JOIST TO PARALLEL RAFTER FACE-NAIL 3 EACH LAP LOCATION LIVE DEAD DEFLECTION LIMIT CLG JOIST LAPS OVER PARTITION FACE-NAIL 3 EACH LAP 1ST FLOOR 40 PSF 12 PSF L/360 RIDGESTRAP EACH END 2 EACH END 2ND FLOOR 40 PSF, 12 PSF L/360 BLOCKING TO RAFTER TOE-NAIL 2-8d EACH END ROOF ROOF 20 PSF 15 PSF L/360 RIM BOARD TO RAFTER END-NAIL 2-16d EACH END ASSEMBLY TAX MAP NO.1000-25:5.8 FOUNDATIONS &FOOTINGS WALL FRAMING # ISSUE/REVISION DATE 1. ASSUMED SOIL BEARING CAPACITY= 1,500 PSF' TOP PLATE TO TOP PLATE FACE-NAIL 2-16d PER FOOT 2. CONCRETE TO BE 3,500 PSI @ 28 DAY TEST; REINFORCE TOP PLATES AT INTERSECTIONS FACE-NAIL 4-16d EACH SIDE .00 FILING SET 05.01.2024 THROUGHOUT STUD TO STUD FACE-NAIL 2-16d 24" O.C. 3. NEW FOOTINGS TO REST ON UNDISTURBED EARTH,WHERE HEADER TO HEADER FACE-NAIL 16d 16" O.C. CONFIRMED TO BE FULLY INORGANIC. NOTIFY OWNER AND TOP OF BOTTOM PL TO STUD END-NAIL 2-16d PER 2x4 ARCHITECT WHERE CONDITIONS ARE DISCOVERED THAT VARY 3-16d PER 2x6 FROM THIS. EXCAVATE AND REPLACE WITH 6" CLEAN FILL OR 4-16d PER 2x8 FLOOR BANK RUN WHERE DEEMED NECESSARY BY ARCHITECT. DRAwNSY:J.LACHAPELLE BOTTOM PLATE TO FLOOR JOIST ASSEMBLY CHECKED BY:1.LACHAPELLE 4. ALL STRUCTURALLY BEARING FOOTINGS SHALL EXTEND BAND JOIST, END JOIST, OR MINIMUM 36" BELOW GRADE. BLOCKING FACE-NAIL 2-16d PER FOOT NOTE:THIS IS AN 11"x 17"SHEET 5. FOOTINGS SHALL BE STEPPED WHERE IT IS NECESSARY TO DRAWINGS MAY BE PRINTED NOT TO SCALE CHANGE ELEVATION.CONSULT WITH ARCHITECT. FLOOR FRAMING 6. FOUNDATION WALL SHALL EXTEND A MINIMUM OF 6"ABOVE JOIST TO SILL,TOP PLATE LaChapelle Architecture PLLC FINAL GRADE, OR AS REQUIRED BY CODE. TO GIRDER TOE-NAIL 4-8d PER JOIST P.0,Box 1251 6. DO NOT WET SET STRUCTURAL INSERTS: SECURE DOWELS, BRIDGING TO JOIST TOE-NAIL 2-8d EACH END Mattituck,NY 11952 THREADED ROD,J-BOLTS,ANCHORS PRIOR TO PLACEMENT OF BLOCKING TO JOIST TOE-NAIL 2-8d EACH END ABBREVIATIONS (646)'251-5058 jakeQlachapellearchitecture.com CONCRETE. BLOCKING TO SILL/TOP PLATE FACE-NAIL 3-16d EACH BLOCK LEDGE STRIP TO BEAM FACE-NAIL 3-16d EACH JOIST A.F.F. ABOVE FINISH FLOOR GWB GYPSUM WALL BOARD FRAMING ALT ALTERNATE JOIST ON LEDGE TO BEAM FACE-NAIL 3-8d PER JOIST BRED �R 1. FRAMING LUMBER TO BE DOUGLAS FIR/LARCH STAMPED BAND JOIST TO JOIST END-NAIL 3-8d PER JOIST APP. APPLIANCE(S) HM HOLLOW METAL \�C STRUCTURAL GRADE NO.2 OR BETTER BAND JOIST TO SILL/TOP PLATE TOE-NAIL 2-16d PER FOOT HT HEIGHTT 2. SHEATHING TO BE APA-RATED,EXPOSURE 1 B.O. BY OTHER HW HOT WATER 3. SUB-FLOORING TO BE APA-RATED, EXPOSURE 1, GLUED AND ROOF SHEATHING ' , RING-SHANK NAILED C/C CENTER TO CENTER MECH. MECHANICAL g 4. AT HEADERS OVER 6' PROVIDE DOUBLE UPRIGHTS;AT HEADERS STRUCTURAL PANELS 8d TABLE 3.8 CLG CEILING MTL METAL s OVER 9'PROVIDE TRIPLE UPRIGHTS DIAGONAL BOARD SHEATHING: CIVIL) CONCRETE MASONRY UNIT 5. HEADERS TO BE (2)2x8 MINIMUM OR AS INDICATED 1"x6" OR 1"x8" 2-8d PER RAFTER CONC CONCRETE PTD PAINTED :���vQ 03393� 6. PROVIDE DOUBLED FRAMING AT ALL OPENINGS INCLUDING VxIO" OR WIDER 3-8d PER RAFTER CONT. CONTINUOUS ©F N STAIRS, ETC. CONT'D CONTINUED RCP REFLECTED CEILING PLAN 7. PROVIDE SOLID BLOCKING AT ALL FLOOR JOISTS AND ROOF CEILING SHEATHING RAFTERS AT MAX. 8'-0", PROVIDE 2" SPACE FOR AIR GYPSUM WALLBOARD COOLERS 5d EDGE 1 D.H. DOUBLE HUNG O.C. ON CENTER CIRCULATION AT ROOF 0" FIELD DIM. DIMENSION 8. PROVIDE 2x6 STUD FRAMING,TYPICAL WALL SHEATHING DIA. DIAMETER SIM. SIMILAR Z. m vnev"ne°m STRUCTURAL PANELS 8d TABLE 3.9 °« T ^° ° r°Oie h` R'Pf. DISC. DISCONTINUOUS S.S. STAINLESS STEEL a"°°=",°.lP. TYlHt" ��""°°��°"4= FIBERBOARD PANELS 8d 3"EDGE DWG DRAWING STL. STEEL REGULATORY NOTES 7/16", 25/32 NAILING SCHEDULE 6" FIELD 1. REFERENCE HEREIN TO 'BC' OR'CODE' SHOULD BE CONSTRUED E ELECTRIC TYP. TYPICAL & PARTICAL BOARD 8d TABLE 3.9 ENG.G. ENGINEER TO MEAN THE APPLICABLE BUILDING CODES OF NEW YORK EQ. EQUAL V.I.F. VERIFY IN FIELD STRAPPING DETAILS STATE. FLOOR SHEATHING -GLUED&RINK-SHANK NAILED EXIST. EXISTING STRUCTURAL PANELS <1" 8d 6" EDGE W/ WITH SHEET NO: 2. TO THE BEST OF MY KNOWLEDGE THE WORK PROPOSED 12" FIELD FL FLOOR WRB WEATHER RESISTIVE S1,00 HEREIN IS COMPLIANT WITH ALL APPLICABLE LAWS,CODES, STRUCTURAL PANELS >1" 10d 6" EDGE BARRIER AND REGULATIONS. 12" FIELD WD. WOOD SHEET 1 OF 8 420 OLD FARM ROAD ORIENT,NY 11957 11j"TJ1210BY i WEYERHAUESER�I DRESSED 6x6 P.T.POST,TYP. @ 16"O.0 1j"x 9}"TIMBERSTRAND 1.55E LSL BY WEYERHAUESER 20'-q" q WOOD DECK i 4'x 18"MICROLLAM .OE LVL BY (3)2x10 HEADER 4x4 POSTS WITHIN FRAMING (3)2x10 HEADER WEYERHAUESER; 0 8 1 i TRUE 2x6 WALL FRAMIN 0 BEARING NORTH WHERE INDICATED i FOR ROOF RAFTE S (2)2x10 HEADER 3Z x 1 1j'TIMBERSTRAND 1.55E BATH 118"TJI 210 BY i LSL BY WEYERHAUESER WEYERHAUESER I" 11j"TJI 210 BY @ 16"O.0 11�TJI 210 BY WEYERHAUESER WEYERHAUESER @ 16"O.0 TAX MAP NO.i000-25.-M @ 16"O.0 LIVING/DINING!KITCHEN MASTER BEDROOM # ISSUE/REVISION DATE 21'-10" 21'-11" 5'4" 15'-1" 00 FILING SET 05.01.2024 o - RAFTERS BEARING ON SEE DWG.S4 WALL ABOVE FOR BEAM i DRAWN 8Y:J.LACHAPELLE CONTINUATION i OF ROOF CHECKED BY:J.LACHAPELLE FRAMING LSL LSL ——— ——————— NOTE:THIS IS AN 11"x 17"SHEET TJI TJI DRAWINGS MAY BE PRINTED NOT TO SCALE UP T IR (3)2x8 HEADER GARAGE � SLAB ON GRADE 9j"TJI 110 BY WEYERHAUESER @ 92"TJI 110 BY r MASTER BATHROOM 16"O.C;DIRECT APPLY CEILING WEYERHAUESER @ 16" LaChapelle Architecture PLLC C' SHEATHING O.C;DIRECT APPLY GWB DN �" P.O.Box 1251 1x11k"TIMBERSTRAND CEILING I Mattituck,NY 11952 1.55E LSL BY TERRACE ENTRY (646)251-5058 jake@lachapellearchitecture.com WEYERHAUESER @ 16" 20.C' ____ _________________ ___________ 6 BATH 1°. 3j"x q'OR 1a'x 11k"TIMBERSTRAND 1�x 9}"TIMBERSTRAND 1.55E LSL BY WEYERHAUESER;COORDINATE FOR HEAD CLEARANCE ARE D 1.55E LSL BY WEYERHAUESER; � q RC C7 ________________ _________________ COORDINATE FOR HEAD CLEARANCE � AC N o �'j� 14"TJI 560 BY 1r x 11k TIMBERSTRAND 1.55E YERHAUESER @ 16"O.C: DIRECT APPLY GWB CEILING LSL BY WEYERHAUESER OPTION TO UPSIZE T016"TJI GENERAL NOTES: 560 FOR INCREASED RIGIDITY F 1. DIMENSIONS GIVEN ON THIS DRAWING ARE MAXIMUM f SPANS,FOR CONTRACTOR'S CONFIRMATION IN THE BEDROOM FIELD-DO NOT BUILD FROM THESE DIMENSIONS;SEE P4-10-' �0. 03343� ARCHITECTURAL PLANS FOR DIMENSIONS Q 2. ALL SUB-FLOOR SHEATHING TO BE GLUED AND OF N RING-SHANK NAILED -- —�— --�--� ����-----�- 3. CONSULT AND FOLLOW ALL MANUFACTURER INSTRUCTIONS FOR THE USE OF THESE MANUFACTURED LUMBER PRODUCTS.THESE (3)210 HEADER;NP. DRAWINGS DO NOT SHOW ALL DETAILS,FASTENING REQUIREMENTS,AND OTHER DATA PERTINENT TO .vrso,ca•a.wx,x rt m ww�"e THESE MANUFACTURED LUMBER PRODUCTS. ronrtmo u`xP°roiws vnacn evornwv°wiica on ioncowevurioNo�iim r�iin`cr'' 4. OBSERVE CODE AND MANUFACTURER LIMITATIONS ON mxwraa rca mxnmrxc w,a•"onsurtor x ay.ue.n xrturvaeeu o rormm m w•uwuveu.wcxirzcrux.rc ALLOWABLE HOLES IN MEMBERS.MEMBERS WITH HOLES OR NOTCHES WHERE NOT ALLOWED WILL BE REMOVED AND REPLACED. SECOND FLOOR & 5, FOLLOW ALL CODE REQUIREMENTS FOR FRAMING. LOWER ROOF 6. 6-MIL OR THICKER POLYETHYLENE VAPOR BARRIER UNDER SLABS ON GRADE,OVER 4"GRAVEL BED(NO FRAMING PLAN FINES);INSULATION PER DETAILS SHEET NO: PROJECT S3mOO O1 CONSTRUCTION PLAN - FIRST FLOOR NORTH SCALE: 1/8" = T-0" SHEET 3 OF 8 420 OLD FARM ROAD ORIENT,NY 11957 CD (3)2x8 HEADER,TYP. TRUE NORTH TAX MAP NO.1000-25.-" OPEN TO BELOW ROOF SLOPE _j # ISSUE REVISION DATE .00 FILING SET 05.01.2024 SEE DWG.S3 1t"x q'TIMBERSTRAND 1.55E LSL BY FOR WEYERHAUESER;COORDINATE FOR DRAWN BY:J.LACHAPELLE CONTINUATION HEAD CLEARANCE CHECKED BY:J.LACHAPELLE OF ROOF (3)2x8 HEADER,TYP. FRAMING NOTE:THIS IS AN 11"x 17"SHEET DRAWINGS MAYBE PRINTED NOT TO SCALE MEZZANINE GARAGE 11pTA360BY LaChapelle Architecture PLLC WEYERHAUESER j SEE DWG.53 @ 16"O.0 T I P.O.Box 1251 FOR GARAGE ROOF FRAMING 21'-6" 1 o DN BATH Mattituck,NY 11952 (646)251-5058 jake@lachapellearchitecture.com (3)2x8 HEADER,TYP, 11p"TJI 360 BY - ( ,C WEYERHAUESER r �LP` / @ 16"O.0 ��. J i le /fir BEDROOM BEDROOM f ( J_ :A m h f GENERAL NOTES: ` 1. DIMENSIONS GIVEN ON THIS DRAWING ARE MAXIMUM SPANS,FOR CONTRACTOR'S CONFIRMATION IN THE ^ G334 � 2 FIELD-DO NOT BUILD FROM THESE DIMENSIONS;SEE 24'-10" \�O z- ARCHITECTURAL PLANS FOR DIMENSIONS 2. ALL SUB-FLOOR SHEATHING TO BE GLUED AND RING-SHANK NAILED 3. CONSULT AND FOLLOW ALL MANUFACTURER INSTRUCTIONS FOR THE USE OF THESE MANUFACTURED LUMBER PRODUCTS.THESE DRAWINGS DO NOT SHOW ALL DETAILS,FASTENING ° n REQUIREMENTS,AND OTHER DATA PERTINENT TO �«h°. ",,°R,�R� THESE MANUFACTURED LUMBER PRODUCTS. ,RD"nooa—THIS°°aw m°o,Foe"rm«`""v�`,",`F°a°fTMwrao"C:°. m°ui°rxis RR°,sc*arm,w nw"o.°MA= m-ou�mr"n RR-lBY 4. OBSERVE CODE AND MANUFACTURER LIMITATIONS ON ° ALLOWABLE HOLES IN MEMBERS.MEMBERS WITH HOLES OR NOTCHES WHERE NOT ALLOWED WILL BE UPPER ROOF REMOVED AND REPLACED. 5. FOLLOW ALL CODE REQUIREMENTS FOR FRAMING. FRAMING PLAN SHEET NO: PROJECT S4mOO CONSTRUCTION PLAN - SECOND FLOOR NORTH O SHEET 4 OF 8 SCALE: = T-0" 420 OLD FARM ROAD ORIENT,NY 11957 TRUE NORTH TAX MAP NO.1000-25.5-8 # ISSUE/REVISION DATE .00 FILING SET 05.01.2024 t ROOF SLOPE ROOF SLOPE 2 _� S7 S7 S7 DRAWN BY:J.LACHAPELLE CHECKED BY:J.LACHAPELLE NOTE:THIS IS AN 11"x 17"SHEET DRAWINGS MAY BE PRINTED NOT TO SCALE LaChapelle Architecture PLLC P.O.Box 1251 s Mattituck,NY 11952 S7 (646)251-5058 fake@lachapellearchitecture.com 2�r D ROOFSLOPE y `_1 i "T 0. 03 9�1� ,n•1, XO R AN INXixu"fM of 6[IxR[w ' ANcxMttION[�U XEMNmLU OPWMRx inLyPX01[ciiON WxttN�rt R[PN[PAXEC6 rt[NYN[PLLC MRs oR4iWW0 mnY 2.E[[uspe00Toi......sFOn Xotx RPNN[NS NxfRXPSMILt.WOxONiNCYWWifCx CO�Nfw[� OiC�PNNCLLN Br ®mPrXmMlOu[ACxnnLL[9xnun[nicxrt C ROOF KEY PLAN SHEET NO: PROJECT S5,00 KEY PLAN — ROOF NORTH O SCALE: 1/8 = 1 -0 SHEET 5 OF 8 PROVIDE STRAPPING THROUGHOUT IN CONFORMANCE 420 OLD FARM ROAD WITH THE REQUIREMENTS OF ORIENT,NY 11957 THESE DOCUMENTS AND OF 2020 BUILDING CODE OF NYS 32"PLYWOOD SUBFLOOR;GLUED& SCREWED OR RING-SHANK NAILED TO JOISTS PER CODE REQUIREMENTS 2x6 STUD FRAMING,TYP. INSULATE PER W SHEETS TRUS JOIST TJIs BY WEYERHAEUSER OR EQUIVALENT @ 16"O.C.;FOLLOW ALL CODE 4"PLYWOOD SHEATHING;SCREW TRUE AND MANUFACTURER REQUIREMENTS OR RING-SHANK NAIL NORTH RIMBOARD BY WEYERHAEUSER OR WATER-RESISTIVE BARRIER, COMPATIBLE EQUIVALENT;FULLY SIDING,ETC.,PER'A'SHEETS BLOCK ALL POSTS(E.G.CORNER FLOOR ASSEMBLY CANTILEVERED FRAMING, KING STUDS,ETC.)FROM OVER FOUNDATION AS LOAD ABOVE TO BEARING BELOW NECESSARY TO ACCOUNT FOR TAX MAP NO.1000-25.-" SEAL RIMBOARD TOP AND THICKNESS OF FOUNDATION BOTTOM INSULATION-CONSULT W SHEETS # ISSUE/REVISION DATE 2x10 P.T.SILL PLATE .00 FILING SET 05.01.2024 SILL GASKET ABOVE AND BELOW EQ. TERMITE SHIELD - e 8"DIA.THREADED ROD ANCHOR r\\\\\\\\\\\\ (MIN.24"EMBED)OR 8'DIA.J-BOLT; d / // //// // // / DRAWN BY:1.LACHAPELLE @ 32"O.C.(6"FROM CORNERS, 12' I I ® \\\\\\\\\\\\\\\\\\ •Q e.l �/ CHECKED BY:J.LACHAPELLE FROM END OF PLATE) I I i $ / NOTE:THIS IS AN 11"x 17"SHEET / DRAWINGS MAYBE PRINTED NOT TO SCALE IF FINISH IS DESIRED USE DRY-GUARD'OSB OR SIMILAR I l I I / / / / / La Chapelle Architecture PLLC FASTENED TO P.T.PURLINS;DO NOT \//\\ ,\\\\/ I •l.I d / / P.O.Box 1251 APPLY IMPERMEABLE COATING Matbtuck,NY 11952 I a • \ice\��\i��\i\\i (646)251-5058 fake@lachapellearchitecture.com BASEMENT FOR FOUNDATION INSULATION, • ° d /\/\/\/\/\/\ WATERPROOFING,DIMPLE SHEET SEE W SHEETS 8"CIP REINFORCED CONCRETE l I \\j\\j\\j\\j\\j\\j 8"x 24"CONTINUOUS CIP �� c �! II° .: z �. . FOUNDATION WALL;#5 BAR @ I I ® \\\j\\\j\\/�\j�\jam\j CONCRETE FOOTING AT \z.r 16"O.C.IN EACH DIRECTION PERIMETER w/(3)#5 BAR CONTINUOUS; MIN.3"COVER f F #5 BAR DOWELS @ 16"O.C.;36" \ \ \/ FOR BAR �:•-� EMBED IN STEM WALL I l a:°111� . `�. l e t PIPE CONNECTION THROUGH d FOOTING CONNECTS PERIMETER °� lei DRAIN TO CRUSHED STONE 4"REINFORCED CONCRETE SLAB w/ IJ ®: a RAINAGE PAD UNDER BASEMENT GALV.WOVEN WIRE MESH PLACED AT I l MIDPOINT OF SLAB;COMPRESSIBLE SC�EDULE 30 PERFORATED PVC FILLER AT PERIMETER aa�°"�" PIPS w/HOLES FACING DOWN,MIN pxcnrtecrvn[P< x [va[°9Yxixw PMn[s P°Pmx[n PPofttn. SLOE 4"IN 100 FT TO DRYWELL; [xP°rsn[x ort ua au°.mv�u[�v°1P"ren�,:�xx[�°x[P[[� POLYETHYLENE 6-MIL VAPOR BARRIER d, ° PLATE PIPE BELOW BOTTOM OF 2"XPS INSULATION(R-10) ___ — d a° -- — ° BAS�MENT SLAB IN CRUSHED �. STO E(NO FINES)WRAPPED IN FOUNDATION DETAILS 4"THICK CRUSHED °�e �, o GEO EXTILE FILTER FABRIC STONE(NO FINES) ° UNDISTURBED EARTH d — — J SHEET NO: O1 TYPICAL FOUNDATION S6:00 SCALE: 1z" = T-0" SHEET 6 OF 8 LSTA18 STRAPPING BY SIMPSON ROOF SHEATHING w/(12)10d NAILS @ EACH RAFTER; LSTA18 STRAPPING BY SIMPSON 420 OLD FARM ROAD LEAVE MIN 22"END DISTANCE w/(12)10d NAILS @EACH RAFTER; ORIENT,NY 11957 LEAVE MIN 28"END DISTANCE ROOF SHEATHING TRUS JOIST TJI BY WEYERHAUESER TRUS JOIST TJI BY WEYERHAUESER I � NO HOLES AT BEARING-REFER NO HOLES AT BEARING-REFER T I TO MANUFACTURER DATA AND O MANUFACTURER DATA AND INSTRUCTIONS INSTRUCTIONS TJ RIM BOARD TRUE i TJ RIM BOARD I NORTH 8d NAIL ONE EACH SIDE, 112" i 8d NAIL,ONE EACH SIDE, 11" I MINIMUM FROM END I MINIMUM FROM END i BEVELED CONTINUOUS BEARING BEVELED CONTINUOUS BEARING PLATE OR VARIABLE SLOPE SEAT - PLATE OR VARIABLE SLOPE SEAT PLAT EO VA (VSA) S OPESIM SEA CONNECTION(VSA)BY SIMPSON TAX MAP NO.1000.25.-" ON :. D13�TOP PLATE AT WALL FRAMING DBL TOP PLATE AT WALL FRAMING ISSUE/REVISION FDA PROVIDE INTERMEDIATE&SHEAR PROVIDE INTERMEDIATE&SHEAR BLOCKING PER CODE AND. BLOCKING PER CODE AND oo FILING SET 24----- MANUFACTURER INSTRUCTION MANUFACTURER INSTRUiTIONS; TYPICAL TOP END BEARING ON WALL INCLUDE BIRDSMOUTH VENTILATION TYPICAL END BEARING INCLUDE BIRDSMOUTH VENTILATION O HOLES IN BLOCKING 1 .-HOLES IN BLOCKING SCALE:�12'" � 1'-0" SCALE: 12" = 1'-0" - DRAWN BY:J.LACHAPELLE CHECKED BY:J.LACHAPELLE NOTE:THIS IS AN 11"x 17"SHEET DRAWINGS MAY BE PRINTED NOT TO SCALE PROVIDE STRAPPING ROOF SHEATHING LaChapelle Architecture PLLC THROUGHOUT IN CONFORMANCE LSTA18 STRAPPING BY SIMPSON P.O.Box 1251 WITH THE REQUIREMENTS OF w/(12)10d NAILS @ EACH RAFTER; Mattituck,NY 11952 THESE DOCUMENTS AND OF 2020 LEAVE MIN 23"END DISTANCE (646)251-5058 jake@lachapellearchitecture.com BUILDING CODE OF NYS TRUS JOIST TJI BY WEYERHAUESER NO HOLES AT BEARING-REFER TO MANUFACTURER DATA AND !`'�s INSTRUCTIONS WEB STIFFENERS PER r„ MANUFACTURER INSTRUCTION . 8d NAIL ONE EACH SIDE, 11' MINIMUM FROM END BEVELED CONTINUOUS BEARING o PLATE OR VARIABLE SLOPE SEAT �����_ ' CONNECTION(VSA)BY SIMPSON DBL TOP PLATE AT WALL FRAMING PROVIDE INTERMEDIATE&SHEAR BLOCKING PER CODE AND ['0R[RKYXo°W.wiWa MYtroY cC uf[D BY°fX W PNmFs°R°M[RPP°Icc& MANUFACTURER INSTRUCTIONS; o„; ,'", a ,t°°„rtca uxc Puc o c°Pr mxr a°Ra ucX.vnu 3 TYPICALTOP END BEARING ON WALL INCLUDE BIRDSMOUTH VENTILATION O SCALE: 1I2 = 1 0 HOLES IN BLOCKING FRAMING DETAILS SHEET NO: S7 ,00 SHEET 7 OF 8 DECK NOTES LEDGER FLASHING i i 420 OLD FARM ROAD 2x8 JOISI,S&LEDGER ORIENT,NY 11957 PROVIDE (2 OR 3)2 c10 EDGE B�AM 1. REFER TO THE LATEST VERSION OF THE AMERICAN WOOD POLYETHYLENE(OR COUNCIL'S'PRESCRIPTIVE RESIDENTIAL WOOD DECK OTHER rr rr rir/ iri r�ir , xr iir i r y iii ii WEATHER-RESISTANT) CONSTRUCTION GUIDE'. i LEDGER SPACERS FOR 2. ALL FRAMING LUMBER TO BE NO. 1 GRADE OR BETTER, GROUND-CONTACT PRESSURE TREATED,[GLUE-LAMINATED DRAINAGE i TIMBER BEAMS ARE ALSO FEASIBLE;IF DESIREABLE PLEASE SIMPSON LUS28 JOIST I CONSULT WITH ARCHITECT FOR SIZING.THEY MUST BE TREATED HANGER,TYP. i TRUE WITH AN OIL-OR WATER-BORNE PRESERVATIVE IN ACCORDANCE ___i___ U) NORTH w WITH AWPA UI. of 3. FLASH TOPS OF FRAMING LUMBER(BEAMS,JOISTS,STRINGERS) > WITH PEEL-N-STICK BITUMINOUS PRODUCT FOR DURABILITY, ! 4. ALL FASTENERS,ANCHORS,WASHERS,ETC.TO BE HOT-DIPPED TYPICAL SECTION i i GALVANIZED OR STAINLESS STEEL,EXCEPT THAT FLASHING TAX MAP N0.1000-25.5-8 FASTENERS MAY ALSO BE SILICONE BRONZE OR COPPER. 5. ALL CONNECTORS(JOIST HANGERS,STRAPPING, ETC.)SHALL BE 60 P.T.COLUMNS HOT-DIPPED GALVANIZED OR STAINLESS STEEL. I # ISSUE/REVISION DATE 6. BEAM SPLICES MUST OCCUR AT POSTS.STAGGER SPLICES WHEN .00 RUNG SET 05.01.2024 COMPOSED OF TWO 2x10S. I ° i. : : SIMPSON COLUMN BASE W/ i. i. STANDOFF ° DRAWN BY:J.LACHAPELLE 18"x18"x12"CIP CONCRETE ,H i• :I •. CD CHECKED BY:J.LACHAPELLE FOOTING w/(3)#5 BAR IN i i . I , EACH DIRECTION, BOTTOM i °' I NOTE:THIS IS AN 11"x 1T"SHEET @ 36"BELOW GARDE,MIN. DRAWINGS MAY BE PRINTED NOT TO SCALE 3"COVER FOR BAR,TYP. e.'-r N LaChapelle Architecture PLLC RAILING NOTE: a a. P.O.Box 1251 PROVIDE 36"RAILING AT Mattituck,NY 1.1952 ALL LOCATIONS WHERE 1; (646)251-5058 jake@lachapellearchitecture.com DROP IS OVER 30" � '♦ 18" _ ROUND OR SQUARE , E D [t FLARED FOOTING BOTTOM �� C;�i ON UNDISTURBED EARTH C)^ _. FR PVC RISER NMs.mc°rrwamsmaucxrau[[� ° [YEDRWxKRR6PREVRR[Dlf 1wr,o(S�Y�YID�tTORD�[imn 9 M'Y 0E MM[EXCEvf ar[PCY/P[4! n6D [RYMtI"iOR OMER PRa[[i5. wnimuimavmmiM•��erto10PCwri`uiiacn'rta*vne`�°Y RE e[[e DECK STAIR DETAIL DECK DETAILS SHEET NO: O1 TYPICAL DECK DETAILS S8mOO SCALE: 11" = T-0" SHEET 8 OF 8 Ro ad APPROVED AS NOTED ZOAMTYWITH ALL COS of B.P 5 088 NEW PORK STATE S TOWN CODES / �/ 1s 3ANDCOND� MSiOF FEE I� , `13Y: `-1 NOTIFY BUILDING DEPARTMENT AT 631-765-1802 BAM TO 4PM FOR THE FOLLOWING INSPECTIONS: FOUNDATION-TWO REQUIRED FOR POURED CONCRETE _ ROUGH-FRAMING&PLUMBING I 14-9-2'f INSULATION FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE PLUMBER CERTIFICATION REQUIREMENTS OF THE CODES OF NEW ON LEAD CONTENT BEFORE PORK STATE. NOT RESPONSIBLE FOR CERTIFICATE OF OCCUPANCY DESIGN OR CONSTRUCTION ERRORS SOLDER USED IN WATER SUPPLY SYSTEM CANNOT DQ NOT PROCEED 1N l h EXCEED 2l10 OF 1% LEAD. FRAM W L TIL SURVEY OF 1TNP MTION -r PLUMBING ALL,,PL,tJMY1Nti WASTE i WAITER LINES NEED TU MIQ IMIRE COVERING ELECTRICAL INSPECTION REQUIRED TR M P ACARDING REQUIltED RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE Must provide Manuals D,J and S as per NYS Energy We rid as Pcr NU COft Blower door ��� and du�whaar�C t�=s ,'requlred. provide Dui ndborrw, debris pm�z4 ion 16 per 2620 Code o� NyS sec . I. 2 . AKT ARCHITECTS architecture + interior design 342 Bowery#3 New York, NY 10012 T: 212.677.7077 0 � Y 2O U- W J z O z CVO W O A Issue Date:4/18/2024 Revisions i No. Date Description r . I 5 i i -- - c 6 I I 8 SCICMD i I Seal & Signature: ----------- ----------- ,�PS� S=MD I SpcMD O ` O �r f'� I I Title: 2ND FL. ELECTRICAL PLAN I I I I I i I I I 1 I I Scale: AS NOTED I Drawing No.: I I I - -- - - j -- ._._._._._..._...__-.__....___...._._ ----_-_-----------------------------------------------------.------------__-.-__.___._---___-_--__-.-_____.-.------_-__--_------_.------_---__-_----_-------------------------..__.____-__----_----...--- -----_--_-..._.---------------.-__.-_.______-_._--__-____.__ -------------____-- E-102.00 2ND FLOOR ELECTRICAL PLAN SCALE: 1/4"=1'-0" N Page No.: 14 OF 14 AKT ARCHITECTS ` 4 < architecture interior design ,tt �. 342 Bowery#3 Compliance Certificate Basement Wail: Solid Concrete or Masonry New York NY 10012 Wan height:8<0' 1,763 0.0 10,0 0.061 0.059 1013 104 Depth below grade: 7.0' T: 212.677.7077 Insulation depth:8.0` v;,L0A,,JC Compliance Statement: The proposed building design described her ith the building plans, specifications,and other Project 420 Old Farm Road calculations submitted with the permit application.The proposed b I h signed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandat , r t I to i REScheck Inspection Checklist. Energy Code: 2018 IECC Anna Thorsdottir, RAC 5/7/2024 5ig Location: Southold, New York Name-Title natu .1"o� pate Construction Type: Single-family M Project Type: New Construction Conditioned Floor Area: 2,190 ft2 Glazing Area 6% Climate Zone: 4 (5572 HDD) Permit Date: LO Permit Number: 0 All Electric true � r is Renewable true " Has Charger true O �/ 7` Has Battery: true W Has Heat Pump: true �G O LL. Construction Site: Owner/Agent: Designer/Contractor: U- W 420 Old Farm Road Lars Westvind Anna Thorsdottir W Orient,NY 11957 0 Z 4 O z Comn�iance: 5.5%Better Than Corte Maximum UA: 581 Your Uk 549 Maximum 5HGC, 0.40 Your SHGC: 0.32 N W The%Better or Worse Than Code index reflects how close to compliance the house is based on code trade-off rules n/ it DOES NOT provide an estimate of energy use or cost relative to a minimum code home. 1L�� 4lalron• .jr adP tradeoffs are no longer considered in the UR or perforrriarice compliance path in RFScIieck, Eac'>stab-on-grade O assembly in the specified climate zone must meet the minimum energy code insulation P-value and depth requirements ,ri 0 ie-iie ,Bm' ....,,�.aa...�ry„r ... ,-.,..N.�. w..k «,c,�, .,,.,, t�ays.•r�<�,w... »c.+s* -.�»a-..,ate..-».,...w;-...,vm,.H<�<w...-'.sae u,_..;.,�;.�+w,....._�..,�s.,•�: .w. ...,-..w ».r..«..,,,,.,,;.z�,.�:,,Y C i'j y F314t Cediirn of Truss 665 (10 0 0,0 0.024 0.026 16 17 Issue Date:5/7/2024 Ceiling 1:Cathedral CcIif61i3 ,8 40 Revisions Wall:Wood Frame, 16"o,c. 3,369 13.0 5,0 0.057 0,06Cr i53 17; i No. Date Description Door:Solid Door(under 50%glazing) 183 0 330 0.320 60 59 1 Garage Door:Solid Door(under 50%glazing) 126 0.330 0.320 42 40 Window:wood Frame SHGC: 0.32 208 0.330 0.320 fig 67 Floor:All-Wood Joist/Truss 1.763 15.0 10,0 0.036 0.047 63 83 3 Garage Floor: Slaty-On-Grade(Unheated) 4 Insulation depth:2,0' 86 10.0 0.700 0.700 0 0 Insulation position: Horizontal Insulation 5 Project Title: 420 Old Farm Road Report date: 05/07/24 Project Title: 420 Old Farm Road Report date: 05/07/24 6 Data filename: Page 1 of 2 Data filename: Page 2 of 2 7 8 Seal &Signature: J 6 U Ar��r F �u y Title: RESCHECK COMPLIANCE Scale: AS NOTED Drawing No.: A-105.00 Page No.: 7 OF 15 GENERAL NOTES DRAWING INDEX AKT ARCHITECTS 1. ALL WORK SHALL CONFORM TO APPLICABLE PROVISIONS OF THE LOCAL BUILDING CODE architecture + interior design AND ANY AGENCIES HAVING JURISDICTION OVER THE WORK ARCHITECTURAL 342 Bowery#3 2. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED INSURANCE AND LICENSES AND T-001.00 GEN. NOTES, SITE PLAN New York, NY 10012 SHALL SECURE ALL NECESSARY PERMITS AND PAY ALL RESPECTIVE FEES PRIOR TO PL RISER DIAGRAM T: 212.677.7077 COMMENCEMENT OF THE WORK. A-100.00 CELLAR PLAN i - . 3. ALL MATERIALS, ASSEMBLIES, EQUIPMENT AND METHODS OF CONSTRUCTION UTILIZED BY A-10100 1ST FLOOR PLAN / �- \` THE GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE SUBJECT TO APPROVAL UNDER I THE PROVISIONS OF THE LOCAL BUILDING CODE. A-102.00 2ND FLOOR PLAN \` 4. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ON-SITE CONDITIONS BEFORE A-103.00 ROOF PLAN SUBMISSION OF PROPOSAL FOR WORK AND SHALL BE RESPONSIBLE FOR SAME THROUGHOUT A-104.00 DOOR SCHEDULE j THE COURSE OF WORK ON THE PROJECT. WINDOW SCHEDULE or 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY SHORING, BRACING AND A-200.00 ELEVATIONS i `� O i' PROTECTING ALL NEW WORK AND ADJACENT EXISTING WORK AND UTILITIES AGAINST , I� NHL \ COLLAPSE, DISPLACEMENTS OR OTHER DAMAGE IN ACCORDANCE WITH STANDARDS OF A-201.00 ELEVATIONS ^ ammm N� ♦ /iin A-301.00 SECTION BB GOOD PRACTICE AND APPLICABLE LAWS. NO WORK CAN COMMENCE WITHOUT OWNER'S A-300.00 SECTION AA / s,?• \ o APPROVAL AND WRITTEN AGREEMENT FROM TENANT TO COMPY WITH BUILDING REQUIREMENTS. / 3?'O" �° RP LO e � 6. ALL WORK SHALL COMPLY WITH ALL CODES, RULES, REGULATIONS AND ORDINANCES IN A-302.00 DETAILS 7 �So, ♦ C FORCE AND EFFECT AT SITE, EXCEPT THAT WHERE DRAWINGS OR SPECIFICATIONS CALL FOR "�.9e Q w ELECTRICAL MORE EXACTING STANDARDS OF LABOR AND/OR MATERIALS, THE MORE STRINGENT - \Wmm. o / REQUIREMENT SHALL GOVERN. LOT 5 �/ ry ry 7. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS OF ALL ITEMS OF WORK TO BE INCLUDED IN E-100.00 CELLAR ELECTRICAL PLAN O 5 BEDROOM SANITARY SYSTEM S ??O•F THE PROJECT. SHOP DRAWINGS SHALL SHOW SIZE, MATERIALS AND METHODS OF ASSEMBLY E-101.00 1ST FLOOR ELECTRICAL PLAN I m O AND INSTALLA11ON IN THE PROJECT. SHOP DRAWINGS SHALL BE SUBMITTED PRIOR TO 500 DAL S.T. " ` E-102.00 2ND FLOOR ELECTRICAL PLAN 1 (2)B'ex6'OEEP LP 150•.----•� �/ FABRICATION, ASSEMBLY AND INSTALLATION. P wNLp 6.x DRY < `J 8. DRAWINGS ARE NOT TO BE SCALED--USE WRITTEN DIMENSIONS ONLY. I ' w CELLAR ENT. M� MIN LPJ B, mq EL(18.5) 24:6':iiiii,•: EL(16.5) 9. CONTROLLED INSPECTION REQUIREMENTS: ITEMS SUBJECT TO CONTROLLED INSPECTION a•.�-a - 5T 0 B.5' :)1...: c ea o Q 7 ARE INDICATED ON SCHEDULE. INSPECTIONS ARE TO BE MADE AND/OR SUPERVISED BY A °o' ° PROFESSIONAL ENGINEER APPROVED BY THE OWNER. e�Ul/" Y ,5D 10.THE CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH REQUIREMENTS OF (MI Z THE ARCHITECT. >: /LL,T a -'a.. �. LOT B 13.6':: P730 POOL:ii::6: :::::.a :; ,� ^ / ^ CL NJ NMfl1t SWI FIRE SAFETY NOTES xs •�""0°Y°1 1. ALL BUILDING MATERIALS STORED AT THE CONSTRUCTION AREA, AND/OR IN ANY AREA OF 74.9' ' 16.0) EL(16.0) I 3 THE BUILDING ARE TO BE SECURED IN A LOCKED AREA. ACCESS TO SUCH AREAS IS TO BE ♦ WE CONTROLLED BY T WASTE WATER OWNER AND/OR THE GENERAL CONTRACTOR. / ER R POOL I Cj ♦ 2.. ALL MATERIALS TO BE STORED IN AN ORDERLY MANNER. 3. ALL FLAMMABLE MAl1-RIALS TO BE KEPT 11GHTLY SEALED IN THEIR RESPECTIVE \� ,? 781= / S 14 CONTAINERS. SUCH MATERIALS ARE TO BE KEPT AWAY FROM ALL HEAT SOURCES. �� MATERIALS TO BE USED AND STORED IN ADEQUATELY VENTILATED Q�P ►, 1 obe ,4 4. ALL FLAMMABLE MATE �P° 419 CL 14.3 SPACES. de�j 1 Issue Date:4/18/2024 5. ALL ELECTRICAL POWER TO BE SHUT OFF WHERE THERE IS EXPOSED CONDUIT. N N �� � j g5oo %� Revisions 6. ALL ELECTRICAL POWER IN THE CONSTRUCTION AREA TO BE SHUT OFF AFTER WORKING � a "a 2zs.4o �s HOURS. j No. Date Description MAKE SUIT` THERE IS NO LEAKAGE OF NATURAL a s 8525•00" w -,6-_ I l i ^,� 7. THE CONTRACTOR; WILL, AT ALL TIMES, N�••--a', �of PAVEMENT fJ� GAS IN THE BUILDING, OR ANY FLAMMABLE GAS USED IN CONSTRUCTION. Ro�3- CL,32 � / /�T�'�/�/ FARM 2 SCOPE OF WORK CL u�� ��i Nmaim 3 RENOVATION AND ADDITION TO AN EXISTING TWO-STORY HOUSE. \ aaa�a , ♦ aw\ aa�N --" 4 /a aaa-Naaaaa as aaaaaa.�+- vow _ �f711C ,aaaaa--a..aaa + 5 VENT ` O O 6 D2N FLOOR R00_F_____ _ _ _ ----_..__-___-_.._.__---_-_---_--_---.------------------------------------...._-..______------ _.e___....__--BATHROOM_--^ N NM7ER% / 7 . 8 2' / DRAINAGE CALCULATION Neu. ' �` NNEll. p PROPOSED DWELLING W/COVERED PORCH: 2528 SO Seal &Sign gn INK 2" �� 2528 x 0.166=419.6 < 420cf REQUIRED (1) 8'DIA x 5' DEEP DRYWELL=221cf PROVIDED a (1) B'DIA x 7' DEEP ORYWELL=310cf PROVIDED WC TUB 01 � 531cf TOTAL SHOWER ,(� JQ 2ND FLOOR -"OVERSIZED FOR POOL WASTE WATER Aft WASTE SITE PLAN -VENT VENT SCALE: NTS 1STFLOORROOF BATHROOM MASTER BATHROOM KITCHEN BATHROOM 2 2' 2" 2" 2„ 2" Title: SINK 2" INK INK INK DW bINK GENERALNOTES LAH WC We TUB WC SITE PLAN PLUMBING RISER DIAGRAM SHOWER SHOWER 1ST FLOOR T " I�__f � i T 7- 2 0" 2' 2" 2" 2" a SYMBOLS 4' 2-12" 2-112" SECTION OR Scale: AS NOTED WASTE WASTE O DOOR ELEVATION NUMBER REFERENCE Drawing No.: LAUNDRY DRAWING NO. • XX DETAIL • REFERENCE WALL TYPE SHEET NO. WASHER DRAWING NO. O SMOKE/ O CARBON CELLAR---__.----__.-__-_---_-._____________________ ________ _ ------------- ------- X SHEET NO. SD/CMD MONOXIDE T-1 00 00 ----------------------_----_-_--_-------- -21 --------_-__-______-______ INTERIOR 2"-- DETECTOR " ELEVATION TO BE TO HOUSE TRAP X A.XX X REFERENCE HARDWIRED Page No.: PLUMBING RISER DIAGRAM X 1 OF 14 SCALE: NTS AKT ARCHITECTS architecture + interior design 342 Bowery#3 New York, NY 10012 r-------t r-------i r------7 r--- r------- r-------i r-------1 T: 212.677.7077 r------, - --' ---- -' I 1 1 ----------------------------------------I '—________—__________--___________--_______---___T__ ____1_______________________________________� ____ 7_________________________—______________ T____—______________----____________---r_______r__________—_—________________________ _______________________________________r____� , -------- ,------ ; ❑ ; ; ❑ ; ; ❑ ; ; ❑ � i I 1 ❑ ; ; � ❑ 1 1 I I 1 1 I I ' L—_----J L_-----J L_--_--.J L---_--J L------J L____.�_J i I i t i I I t t I I I 1 1 ' I ' 1 ' i ; I WOOD DECK ABOVE I t I ' I I j 66'-4" t --- ------------ ------------------------------------------------------------------------------------------------------------------------------------------------------------- 1 O � i I ' ---------------------------------------------- ----------------------------------------- ------------- ._...- - ------------------------------------------------------------------------------ --------------------------------------�--- ry I HOUSE TRAP TO CONNECT TO SEPTIC SYSTEM,LOCATION TBD JJ' 0 r1 I I � LL 1 , t ' w ' z I i i J t ' O G ; ! N LU I 1 I � 1 t � 1 t � a I I - ---- -- - i CELLAR I ; 1 I , 1 I , 1 , I 1 � --- --------- --------------------------------------------------- 22'-0" ; I ' I ; I 1 I Issue Date:4/18/2024 k co j Revisions I No. Date Description 1 I 9'-10" 6'-9" 4'-0" t 1 I 1 1 2 1 ; , _ I rANEL I j L--------------- -- I L--- ----r------------------------------------------------------------ o UP 10 13'4" co 16 RISERS @ 7. 6" W i i 4 11 RE D 1 , i " I I SLAB ON GRADE In ih I I 1 t 5 WOOD DECK ABOVE ; � MECHANICAL ROOM ~ Di i I I 10° 4'-7" I 1 6 1 1 I I 7 t I � , Ij 7„_11" ----------------------------- o ; 8 ---------------- ------------- ---� In 1 1 10'-9" Seal & Signature: < "x fih '� --------------------------------------- 1 I �'ED ARC`S,. I 1 1 I L--- -------------.-- --------- -------! 1 1 1 ----$ ----- i S SQp�C, t i 1 ♦ r I I ; 1 I � } 5 / " _ 1 L----------------------------------------------------------------------------------------------------- .—"`--___J <O 1 Title: � 1 1 1 CELLAR PLAN 1 1 1 1 I 1 t I 1 t I 1 I 1 I 1 1 CLip t I Scale: AS NOTED I I Drawing No.: IL � 9 1 ------------------------------------------------------------------------------- -------------------------------- ---------11 I ' 1 I I ' I ' I 1 --------------------------- ---- 26'-6" A-100.00 CELLAR PLAN N SCALE: 1/4"=1'-0" ._ Page No.: 2 OF 14 AKT ARCHITECTS architecture + interior design 342 Bowery#3 New York, NY 10012 T: 212.677.7077 66'-2" I I I i N i WOOD DECK � I LO I I I T-7" 8'-3" 3'-5" 14'-10" 2'-8" 0 r 14 15 CL WINDOWS W/ 13 18 OPPOSITE WALLE(I BATHR M 3'-2" 3'-6" N 0 5'-11" 0 O � O m l.L.. Qq 17 I �o U- I W 12 �° z J I I ' � I LIVING/DINING/KITCHEN o I + MASTER BEDROOM z AREA=745SF °' `o - `D AREA=235SF CO N LLI REQ.VENTILATION=37.25SF I REQ.VENTILATION=11.75SF o ACTUAL=40SF I ; D1N 1 ACTUAL=31SF O o REQ.LIGHT=74.5SF I I j REQ.LIGHT=23.5SF N ACTUAL=80SF ACTUAL=51SF 21'-6" I 10 GARAGE Cl) IR T-0" 5'-0„ 3'-10" o Issue Date:4/18/2024 I 24,-9„ 5'-5„ i 6,- „ [g Revisions No. Date Description 0 2 1 2� 2l1" 1�1G�1 I , 2 i 16 1 USERS @ 7. 6" MASTER 12'-8" IF -- 8-0 up 11 R D 0 BATHROOM - 3 I o � CV cn 4 N TERRACE 10'-6" 9 5 zo I I o o O ENTRY °0 6 DN [�D I I T-0„ --- - ------------------------ - ---------------------- - ------------------------ - -- ' I ELEC. O 8 3'-0" 7'-2" 3'-0" 0" CAR o o Seal & Signature: J 4'HARGE CL Cl) _, ch I i co EQ. EQ. ® ;---------- ---- ------ --- ------------- ---------- - - -- F}��O `,c1 BATHROOM -------------- l--i------ --------- -- - ---------------------- --- - EXHAUST ^Cj T\ -------- 75 4>< CFM -7" 2'- ' 6'-7" q !C 51 0 �7 © BATH ROOM ------------------------------- , ��- '17 BEDROOM AREA=300SF Title: REQ.VENTILATION=15SF N ACTUAL=66.5SF 1ST FLOOR PLAN O REQ.LIGHT=30SF O ACTUAL=66.5SF I I Scale: AS NOTED q q i 24'-10" L Drawing No.: --------------- ----------------------------------------------------------------------------------------- -----------------------------------------------------------------------------------------------------------------------L A-101 .00 1 ST FLOOR PLAN N SCALE: 1/4"=1'-0" Page No.: 3 OF 14 AKT ARCHITECTS architecture + interior design 342 Bowery#3 New York, NY 10012 T: 212.677.7077 19 Q Q � O 'Ile 0/ O LJL ROOF OPEN TO BELOW -j z ' SLOPE O 1- c) z IN mow/ O Issue Date:4/18/2024 Revisions No. /Date Description 16 15 ' ,I 1 7i ^ T-0"HT RAILING 2 21'-2" 4'-4" EQ. EQ T-6" N Q o 3 4 1 GARAGE in CP 5 zo MEZZANINE F., IS RS 7. 6" 6'-5" DN R D 6 io T-0" BATHROOM 7 8 0 N 19 Seal & Signature: 18 ------------ ----------- ----------- ------- 21 20 j t ------------- r ---------------------------------------------------------------------- ---- BEDROOM BEDROOM ` AREA=153SF AREA=170SF I REQ.VENTILATION=7.7SF REQ.VENTILATION=8.5SF ACTUAL=29.5SF ACTUAL=TBD Title: z,, REQ.LIGHT=15.3SF Q 7SF ACTUAL=29.5SF ACTUAL=TBD 2ND FLOOR PLAN ' 11 14 t i I I i o Scale: AS NOTED tn LO 11'-6" 12'-11" Drawing No.: i -------------------------------------------------- --'---------------------------'----'-_-..-----------------------------------------------------------------------------------._._.-----------'---------------------------------------------------------- �8'-3" 12 3'-8" 13 8'-3" A-102.00 2ND FLOOR PLAN N SCALE: 1/4"=1'-0" Page No.: 4 OF 14 AKT ARCHITECTS architecture + interior design 342 Bowery#3 DOWNSPOUT New York, NY 10012 I i T: 212.677.7077 I I I I I I I I I I I I I I I ! DOWNSPOUT 0) I 1 I I � I Q r 0N I I I ' L.L.. I I � 0 ry ' a ! E E LL E E Wt E o z E t ` J I SLOPE SLOPE 0 1 E O z I N W 1 I 1 t 0 t t I t NOTES I 1. PROVIDE CATCH BASINS @ DOWNSPOUTS AS SHOWN 2. DOWNSPOUTS TO GO TO GROUND&CONNECT TO NEW DRYWELLS 3.SOLAR PANELS @ ROOF BY OWNER,LOCATION&QUANTITY TBD 4 k 4 t t Issue Date:4/18/2024 I I Revisions t No. Date Description I DOWNSPOUT !jiJl/ J71 I < rl Ova I o 2 I I I 3 I ; I 4 I I 5 I 6 I I I 7 I 8 I I Seal & Signature: DOWNSPOUT SLR i I E Title: ROOF PLAN ! I ! I I I I I t I I I I I I I I I 1 I Scale: AS NOTED I I ! DOWNSPOUT Drawing No.: ! 1 I I I I ! 1 ! 1 _______________________._-____________.__-.-____-_--__--.---.-_---_------------------------...--------- o --------------------------------- A-103.00 ROOF PLAN N SCALE: 1/4"=1'-0" Page No.: 5 OF 14 AKT ARCHITECTS architecture + interior design DOOR SCHEDULE WINDOW SCHEDULE 342 Bowery#3 New York, NY 10012 NO. TYPE SIZE WxHxTH VIF SADDLE HARDWARE NOTES NO. LOCATION SIZE WxH VIF TYPE MATERIAL CONFIGURATION NOTES/SPEC T: 212.677.7077 D1 A 3'-0"X 7'-0"X 1-3/4" TBD TBD ENTRY DOOR 1 CELLAR TBD A TBD CS TBD D2 A 3'-0"X 7'-0"X 1-3/4" TBD TBD GARAGE SIDE DOOR 2 MASTER BATHROOM 2'-8"x 4'-10" A TBD CS ANDERSEN 400 SERIES CN15 D3 A 2'-6"X 7'-0"X 1-3/4" TBD TBD CELLAR STAIR DOOR 3 ENTRY 6'-0"x 2'-0" B TBD FX ANDERSEN 400 SERIES A61 D4 A 2'-6"X 7'-0"X 1-3/4" N/A TBD LAUNDRY CLOSET DOOR 4 STUDY 2'-8"x 4'-10" A TBD CS ANDERSEN 400 SERIES CX15 D5 A 3'-0"X 7'-0"X 1-3/4" N/A TBD STUDY ROOM DOOR 5 STUDY 6'-0"x 2'-0" A TBD FX ANDERSEN 400 SERIES A61 D6 A 2'-6"X 7'-0"X 1-3/4" TBD TBD STUDY BATHROOM DOOR 6 STUDY 6'-0"x 2'-0" A TBD FX ANDERSEN 400 SERIES A61 D7 C 17'-6"X 7'-3"X TBD N/A TBD AUTOMATED GARAGE DOOR 7 STUDY 6'-0"x 2'-0" A TBD FX ANDERSEN 400 SERIES A61 D8 A 3'-0"X 7'-0"X 1-3/4" N/A TBD MASTER BEDROOM DOOR 8 STUDY 2'-8"x 4'-10" A TBD CS ANDERSEN 400 SERIES CX15 Q r D9 A 3'-0"X 7'-0"X 1-3/4" 7 TBD TBD MASTER BATHROOM DOOR 9 MASTER BATHROOM 5'-0"x 2'-0" B TBD FX ANDERSEN 400 SERIES A51 O r D10 A 3'-0"X 7'-0"X 1-3/4" N/A TBD CELLAR MECHANICAL ROOM DOOR 10 MASTER BEDROOM 3'-0"x 6'-0" C TBD FX ANDERSEN 400 SERIES P3060 N� L.L.. D11 A 3'-0"X 7'-0"X 1-3/4" TBD TBD CELLAR ENTRY DOOR 11 BEDROOM 2'-8"x 2'-8" B TBD AW ANDERSEN 400 SERIES AW281 ���2 O D12 A 2'-8"X 7'-0"X 1-3/4" TBD TBD OFFICE BATHROOM DOOR 12 BEDROOM 3'-0"x 4'-4" A TBD CS ANDERSEN 400 SERIES CXW145 LL D13 A 2'-8"X 7'-0"X 1-3/4" TBD TBD OFFICE BATHROOM EXTERIOR DOOR 13 BEDROOM 3'-0"x 4'-4" A TBD CS ANDERSEN 400 SERIES CXW145 V.. W D14 B 6'-0"X 7'-0"X TBD TBD TBD OFFICE GLASS SLIDING DOOR 14 BEDROOM 2'-8"x 2'-8" B TBD AW ANDERSEN 400 SERIES AW281 Q J z D15 B 6'-0"X 7'-0"X TBD TBD TBD LIVING ROOM GLASS SLIDING DOOR 15 BATHROOM 5'-0"x 2'-0" B TBD AW ANDERSEN 400 SERIES A51 O D16 B 6'-0"X 7'-0"X TBD TBD TBD LIVING ROOM GLASS SLIDING DOOR 16 STAIR 6'-0"x 3'-0" C TBD FX ANDERSEN 400 SERIES PX6045 KIT GLASS SLIDING DOOR 17 OFFICE BATHROOM 2'-8"x 2'-8" B TBD AW ANDERSEN 400 SERIES AW281 N W D17 B 6'0"X 7'0"X TBD TBD TBD LIVING ROOM/ CHEN G S S d' 18 2ND FLOOR MEZZANINE 6-0"x 3'-0" C TBD FX ANDERSEN 400 SERIES PX6045 EE D18 B 6'-0"X 7'-0"X TBD TBD TBD MASTER BEDROOM GLASS SLIDING DOOR 1 O D19 A 2'-4"X 7'-0"X 1-3/4" TBD TBD 2ND FLOOR BATHROOM DOOR 19 KITCHEN UPPER 6'-0"x 3'-0" C TBD FX ANDERSEN 400 SERIES PX6045 D20 A 2'-6"X 7'-0"X 1-3/4" N/A TBD 2ND FLOOR BEDROOM DOOR NOTES D21 A 2'-6"X 7'-0"X 1-3/4" N/A TBD 2ND FLOOR BEDROOM DOOR ALL WINDOW SIZES TO BE'VERIFIED IN FIELD BY INSTALLER/CONTRACTOR. — Issue Date:4/18/2024 FriIII Revisions No. Date Description ��� Q TYPE A TYPE B TYPE C 1 l CASEMENT AWNING NJINDOW PICTURE WINDOW `� Rua, , WINDOW ` 2 3 TYPE A TYPE B TYPE C TYPE D TYPE E 1%"SOLID CORE SLIDING GLASS DOOR AUTOMATED GARAGE DOOR POCKET DOOR W/ GLASS DOOR WOOD DOOR ON WOOD FRAME VISION PANEL 4 5 6 7 8 Seal &Signature: r. ,. Title: DOOR SCHEDULE WINDOW SCHEDULE Scale: AS NOTED Drawing No.: A-104.00 Page No.: 6 OF 14 AKT ARCHITECTS architecture + interior design 342 Bowery#3 New York, NY 10012 T: 212.677.7077 ---- ---------------------------------------------------------------- -------------------------------------------------------------------- - 12 13 -- 1'^_ - ON o ry i N 5 LO ----------- -- __- ------------_--_-__--____-___-----_--_______-__-_-__---_--___-_-______-_________---___-_-_______-________-___-----__--____-____ o N 8"HORIZONTAL SIDING O O O O IQ W --- -- o Z GARAGE DOOR _-_ ---—._._._-- -------------------------------------- 1. FRONT ELEVATION-EAST SCALE: 1/4"=1'-0" Issue Date:4/18/2024 Revisions No. Date Description 3 — ----- - - _.--------.-.._...__._._...._. _— ------ -- -- -- -----------------------_— -- _ 4 -.__------ ------____-----------___----------------------------------- -- - ---- ----- - - - - -....-..-......-.. .... _._._----------------------------- _-.. --------- ---- --- —--- 5 - _..----------- _.---.----_---__-_ 6 _ GUTTER @ FASCIA 8 - -- - Seal & Signature: o - -� -.... .._-__—_-- ---------- _ --- - - - - ---- -- -- - P E D ARC ------------------ - - -- ---- - -- - -- -------------------- 04 N BATHROOM EXHAUSTCD N O U A i.l ; 1L'• r.�i�4';i��'�'� — Title: 8"HORIZONTAL SIDING ELEVATIONS WOOD DECK Scale: AS NOTED CONNECTTO CONNECTTO CONNECTTO DRYWELL DRYWELL DRYWELL Drawing No.: 2. SIDE ELEVATION-NORTH SCALE: 1/4"=V-0" A-200.00 Page No.: 7 OF 14 AKT ARCHITECTS architecture + interior design 342 Bowery#3 New York, NY 10012 T: 212.677.7077 ------------=-- - �� ---------------------------------------------------------------------------------------- ------------ - __. LO _ o -- ------------------------------------------------------_-----_-------------------------------------------------------------------------------------------------------------------------------------------------- L.L 0 `} 2 18 17 16 1© ® ® L W J Z ----- ---- ----- --- ZI! 8"---HOR---- IZONTAL SIDING .......-.....--..._.—. --------- — - -- 0 Z -jilCV W WOOD DECKF--- Lj 11 .. ' CONNECT TO DRYWELL —CONNECT TO DRYWELL 1. REAR ELEVATION-WEST SCALE: 1/4"=1'-0" Issue Date:4/18/2024 Revisions No. Date Description - —— — - --- — — -- — 2 - -- _— A w__ -------- 3 —_--_-----_--- -_----_--- —_----------------_-----_-— —__ — - 5 �` 11 6 / t - _ = 7 -___ - - ---- — �. __ --- 8 ------ - ---- --—_— ------- --------- ----------- Seal --- ----------- ARC N , ♦ 4 lam/ —__ .t � a '1 s%•r-w�' ♦ 1 Title: _ -- I ELEVATIONS 8"HORIZONTAL SIDING WOOD DECK - Scale: AS NOTED Drawing No.: 2. SIDE ELEVATION-SOUTH SCALE: 1/4"=1'-0" A-201 .00 Page No.: 8 OF 14 T ARCHITECTS A-302 architecture + interior design 2 342 Bowery#3 &m_1mWWmNV'mmyNm� -------- I New York, NY 10012 T: 212.677.7077 is i I --- ----------------- I ti -- i L0 Q � I � ' 20 I LL W c%> RAIL @ MEZZANINE i Q O 1-7 -—-----------------------------.----—---------- Z N W ------_ -- ----------------- -- i 1r Issue Date:4/18/2024 Revisions No. Date Description De/sc/riiption --� � FINISH EXTERIOR 1 �a � Rvl h"iot 8"HORIZONTAL SIDING 2 4 ZIP SYSTEM FINISH GWB 5 R-SHEATHING W/ ZIP SYSTEM TAPE 6 INSTALLED OVER INSULATION -- — ALL PANEL SEAMS 7 FINISH FLOOR 8 Seal &Signature: ° FLOOR FRAMINGIyG g 31 " FRONT TERRACE FRAMING ` ' 4' - r► y . SECTION AA SCALE: 1/2"=1'-0° e' a ♦a �f f 1! , 'S�J'V ♦11 ,. If. Title: j SECTIONS 4 II d II I�Ip Y I � . II °II 0 11 11 II Scale: AS NOTED d I� ^ d ♦J. Drawing No.: II / ti SPRAY-ON INSULATION(TYP.) n II CONCRETE FOUNDATION WALL l l'll II II 11 I✓I 3"CONCRETE SLAB W/COMPRESSIBLE FILILER d II II a (' tl POLY VAPOR BARRIER II It 2"STYROFOAM INSULATION t A-300.00 II 0 : I , xa a �I b ♦ ^ b! II v.+l.7�r7E4i:�.+sit:"st:ittfi�#x'{�ft��-�t`Ffs:�F:_ $�k�t�t3F1£1i �#iiiil�+�}�1�+1�i"ff�rfl"fii�f31N#�":}#�r.+�{if{i�i �4FEL+i�F{E�1t' DRAIN PIPE ON GRAVEL BED ^; < ° Page No.: 9 OF 14 AKT ARCHITECTS architecture + interior design 342 Bowery#3 New York, NY 10012 T: 212.677.7077 U Q O � �- A-302 A-302 1 2 2 O LL w E � ii Ei E � O F , F4 E , 7 O Z I , ` _ _ _____.___._____...______________________1� may, ,. ______ _____—_—___..___________..._ a O I�IE GARAGE DOOR TRACK I Ij Issue Date:4/18/2024 I Revisions No. Date Description GARAGE DOOR 1 SLAB ON GRADE W/SLOPED UP 24"SKIRT @ ENTRY 2 i 2"STYROFOAM INSULATION 3 I I ' POLY VAPOR BARRIER 4 5 i i -. If` �' I-1i{ iif I—III=-E =Ili=ii,_If1�ii—f)l � FLOOR FRAMING 7 o CONCRETE FOUNDATION WALL Cl) 8 ° Seal & Signature: BRED as � ' DRAIN PIPE ON GRAVEL BED e q p r ` a 177,1. r?.t m Title: SECTIONS a a , 4 d ' am e Scale: AS NOTED a an e` a Drawing No.: .�`�v, % =1" #�t t: •r is �� 7:" 7. - "€"i,, �lkE�I.t'3"r(ti +;.r. t..ti'�aEfylz}� c i"E;'�A;I: SECTION BB SCALE: 1/2"=1'-0" /�A -301 .00 Page No.: 10 OF 14 AKT ARCHITECTS architecture + interior design 342 Bowery#3 ROOFING New York, NY 10012 T: 212.677.7077 FLASHING RIGID INSULATION FASCIA y y y� Wm� V �\ 8\WN\ fM ti LID C) Cy) ROOF FRAMING W/ SPRAY-ON INSULATION ZIP SYSTEM R-SHEATHING W/ ' ' 2 O ZIP SYSTEM TAPE INSTALLED OVER �- ALL PANEL SEAMS I Q W i WALL FRAMING W/ SPRAY-ON INSULATION it FINISH EXTERIOR SIDING -=----------- ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- �- — ll O l l /l GARAGE DOOR , r ; r i 1. ROOF & WALL DETAIL @ GARAGE SCALE: 1"=1'-0" Issue Date:4/18/2024 Revisions No. Date Description 2 RIGID INSULATION 3 ROOFING FLASHING 4 5 d A FASCIA 6 7 ROOF FRAMING W/ SPRAY-ON INSULATION Seal &Signature: �pFED SRC, H FINISH EXTERIOR SIDING �S y��F ZIP SYSTEM R-SHEATHING W/ ZIP SYSTEM TAPE INSTALLED OVER ALL PANEL SEAMS �:� `1 Ilk- WALL FRAMING W/ SPRAY-ON INSULATION ` ��i I _:i o W AIR & MOISTURE BARRIER, Title: VAPOR PERMIABLE DETAILS SLIDING DOORS Scale:AS NOTED Drawing No.: 2. ROOF & WALL DETAIL (TYP.) SCALE: 1"=1'-0" A-302.00 Page No.: 11 OF 14 AKT ARCHITECTS architecture + interior design 342 Bowery#3 New York, NY 10012 r r-------I r-------i r------ r_-_-_..-,_? r-------I r-------I r-------I T: 212.677.7077 _;-------------__-___ -----------------=.__��__-;__--_-________-------------- ;--�-;--------__------------------------____;_-�-;_-__________-._----------_____________;.__... ,_.._;_____..-__.-__..__.-______-__.-__-._-.----.---r-D--;.----__-_.-_-__-__-__-______________----.r-.- -..r.____.--------------------------------'.-a' ; Ut I i I I I i I 1 I i ! t I I I I I ! i I i I i I I I L______J L______J L______J L__.-.-__J L______J L______J L____.�_J t I I I f f , I 1 1 i I i I 1 ; I I 1 ' I ; I I L i iL -__--_-----_._._-_-__.__________________________________________________________________________.-_________-__--_----__-----_--_--_ I 1 I ; I ------------ --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- i � f 61 2� O ; ry 1 , I , I , ' -------------- -------------- 1 � LL - J o Z I ' N W i E 1 1 I I 1 � � 1 i Issue Date:4/18/2024 ------- 1 ' - Revisions I i I ! _ No. Date Description ------------------------------------ 1 L---------------------------------------- ------- ---- I iCOW 2 i 1 1 i CONDENSER L___ -___ L I 1 3 --------------- _ AC I 4 I I i ____'--____.-._..___-..._.-._...---._-_ _.__- .___-_ A A I i 5 DRYER� C V i I i ; I L----------------------------------- I Seal & Signature: I ----------------------------------------------------------i--- I 1 ' 1 -------------- ---`------------------------------ J--- 17 -------------------------------------------------------- i i 1 � 1 1 I 1 Title: I i 1 CELLAR ELECTRICAL PLAN I i 1 i I I 1 ! 1 i i 1 I Scale: AS NOTED Drawing No.: i I 1 i i 1 1 E-100.00 CELLAR ELECTRICAL PLAN N SCALE: 1/4"=1'-0" Page No.: 12 OF 14 AKT ARCHITECTS architecture + interior design ---_ - - -_- - 342 Bowery#3 ---- -- - ---- New York, NY 10012 T: 212.677.7077 LO I 1 1 I I I I I 1 1 I 1 � I 1 I 1 I I I 1 i I I I I I I i 1 _------ ---------------- __ ------- '" _ - _ _---- ---- J tc 3GFI 4C4 IY� i I H OD ----------------- / A 1 _----___ I t I I , I SGCMD � t O I I 1 tttl � 11 O ; I j I GFI- I ; T--- CV _W T_-'__1 1 ``t I I % O I / I t F DW I -- —_ — , I I I / I _—.__-._...___.._....._,_--.__..__.__.-______----------—.__»_-_- OR NOTE 1.GARAGE LIGHTS TO HAVE MOTION DETECTOR OVERRIDE 2.PROVIDE CHARGER FOR ELECTRIC CAR I iI I REF SGCMD j I Issue Date:4/18/2024 I SGCMD O 3; 31 ; ; i GFI 1 i Revisions SGCMD ( I I I No. Date Description Q j j 01 u7 I I ------------ •, 2 1 --' --- / A i jA 4 tt I 5 --------- -i == I / -- --------------------- - - ; 7 r---I ---------- - ---- -- - --------- - --- GAI LAC E DOORw------- — i'IT 8 1 I1 i 11 ELEC.CAR CHARGER __.._...--..__- ' _---- i S Seal &SignatuYre1'd 4: [�D - S' _ .____ _-. _- _, _ _----_.-..._-_--__-__.._.__..__..................._..__ 4 EL PEC ANELI 1 I ...._._____—___..—__—___ _—..—______-___..__._____--_.__.. SGCMD O I I I c i I t I D HEAT ETECTOR GFIS \` ---------------------------------------------------------------------------------------------------------------- I - _ =I I Title: I 1ST FL. ELECTRICAL PLAN I I I I ------------------ Scale: AS NOTED I Drawing No.: 1 1 I 1 1 I I 1 I _.,._... .._.._. ..__.__—r E-101 .00 1ST FLOOR ELECTRICAL PLAN SCALE: 1/4"=1'-0'- N Page No.: 13 OF 14 r ` a } w ar, _ • , . r .i� d 9 f�. 'F -N.IF �- i '� t t a rt V _ ._... e..� i w .. •::; J � ya Tu �� r� i t � y J F T £� �> • �}.., Ys ` �� .;y :� � �.� _ems _�, "�"' � r � � .� t` + 1/t .i op - _ for lip • - fr. . r j, • Afr E s Ale 4 • +� 41 r 40 i + R.AW - F • IF ' • r F • oil . �r y IAw I K I I Y 'i S` ,Y r- 1 mil I S E : t �i dJ� "w,w•�„ �µ�i •F 1 Lit - •. �� 1� T71- n,Wr .V wn 71'P �`•��UR£ ' hA,AR 3 0 2026 '� r� 091fii?6�9 fi ,Art y ��_► �.�•-.�.�� ram^ _" .��_ n .;L1. jr I i�