Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
51795-Z
~o��pF SOUTyo`O Town of Southold * P.O. Box 1179 Q 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46967 Date: 04/13/2026 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 705 Birch Ln Cutchogue, NY 11935 See/Block/Lot: 83.4-26 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 02/24/2025 Pursuant to which Building Permit No. 51795 and dated: 04/01/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof mounted solar panels to an existing accessory garage as applied for. The certificate is issued to: Casarona J Revoc Trt i Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51795 4/l/2026 PLUMBERS CERTIFICATION: %L1 1 0 % A tho ' e Signature o40fSO�ryo TOWN OF SOUTHOLD BUILDING DEPARTMENT ' TOWN CLERK'S OFFICE caumr. o SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51795 Date: 04/01/2025 Permission is hereby granted to: Casarona J Revoc Trt PO BOX 1149 Cutchogue, NY 11935 To: Install roof mounted solar panels to an existing single-family dwelling as applied for.Additional certification may be required. Premises Located at: 705 Birch Ln, Cutchogue, NY 11935 SCTM#83.-1-26 Pursuant to application dated 02/24/2025 and approved by the Building Inspector. To expire on 04/01/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 CO-RESIDENTIAL $100.00 ELECTRIC -Residential $125.00 Total $325.00 j zA i)-- --- Building Inspector SO(/l�olo - Town Hall Annex Telephone(631)765-1802 54375 Main Road c/> Aar P.O.Box 1179 • i0� Southold,New York 11971-0959 ��'�Courm,��' BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Casarona J Revoc Trt Address: 705 Birch Ln city: Cutchogue St: NY zip: 11935 Building Permit#: 51795 Section: 83 Block: 1 Lot: 26 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Electrician: SUNation License No: 33412ME SITE DETAILS Office Use Only Commercial Indoor X Basement Service Solar X Residential X Outdoor X 1st Floor Pool Battery Storage As-built Renovation 2nd Floor Hot Tub EV Charger New Addition Attic Spa Generator Survey Mezzanine Garage Dock INVENTORY Service 1 ph In-wall Heater Recpt Ceiling Fixtures Smoke Detectors Pump Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures CO Detectors Heater Main Panel A/C Condenser Single Recpt RecessdFixtures Combo Smoke/CO Transformer Sub Panel 100 A/C Blower Range Recpt Ceiling Fan Heat Detectors Salt Gen Transfer Switch Mini Split Dryer Recpt UC Lights Fridge AutoCover ARC Blower Heads Switches Pucks Lights Dishwasher Mini Fridge GFI Disconnect 40A Emrgency Strobe 4'LED Microwave Garbage Disp. ARC/GFI ERV Exit Lights I Bath Exhaust Hood Dehumidifier Other Equipment: 9.24kW Roof Mounted PV Solar Energy System w/(22)SEG-420 BTG-BG Modules, Tesla Inverter Model 1538000xx 240V, 40A AC Disconnect, 100A Leviton Panel- Notes: 20 Circuits /4 Used w/ Backfed 40A Breaker Solar on Acc. Garage Feeding to Meter on House 1 Inspector Signature: Date: April 1, 2026 OF SOUTyOlo �� # # TOWN OF SOUTHOLD BUILDING DIPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [: ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: �U V GV G IZC�[J 22 DATE INSPECTOR L� pF SOUTyO� ' TOWN OF SOUTHOLD BUILDING DEPT. o m, �0 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING/STRAPPING [ FINAL Jo(o)� [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]. RENTAL REMA DATE v INSPECTOR DATE FIELD INSPECTION REPORT I TATE COMMENTS T) FOUNDATION (IS ----------- --------- -------------------------------------- -- FOUNDATION (2ND) ------ ROUGH FRAMING & ------------ PLUMBING ----------- -------------- - INSULATION PER N. Y. STATE ENERGY CODE n FINAL ------------ ADDITIONAL COMMENTS -25 L-41 0 .......... .... ... Arn;u 70 ............. ------- ---------------- ------ ....... ---------- ....... CTI ro ------------------ ------- O�goFFOtK�G TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 N 2 Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT 1 q For Office Use Only PERMIT NO. 1 f� Bu ilding Inspector: Sig �� lh rt e ID09 160 oa Applications and forms must be filled out in their entirety.Incomplete ��id;�A �cypV applications will.not be accepted. Where the Applicant is not the owner,an .��apl'�C Owner's Authorization form(Page 2)shall be completed. Date: ';,--)/QD a.5 OWNER(S)OF PROPERTY: Name:Joseph Casarona SCTM#1000-83-1-26 Project Address: 705 Birch, Cutchogue, NY 11935 Phone#:347-888-7844 Email: jcasarona@mac.com Mailing Address:P.O. Box 1149, Cutchogue, NY 11935 CONTACT PERSON: Name: Evelyn Polvere/Sunation Solar Systems Mailing Address: 171 Remington Blvd., Ronkonkoma, NY 11779 Phone#: 631-750-9454 ext 346 permitting.@sunation.com DESIGN PROFESSIONAL INFORMATION: Name:Michael Dunn Mailing Address:256A Orinoco Drive, Brightwaters, NY 11718 Phone#: 631-665-9120 Email:glenn@grahamassociatesny.com CONTRACTOR INFORMATION: Name:Scott Maskin/Sunation Solar Systems Mailing Address:171 Remington Blvd., Ronkonkoma, NY 11779 Phone#: 631-750-9454 Email:permitting@sunation.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes RNo 1 PROPERTY INFORMATION Existing use of property:Residential Intended use of property: Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ®No IF YES, PROVIDE A COPY. 111 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law. Application Submitted By(print name): Sco askin BAuthorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Scott Maski n being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the. Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this b day of —f�YJ;n V'i6wn ,20�� i Notary Public LYNN VITA Notary Public, State of New York Registration #01V15068399 Qualified in Suffolk County PROPERTY OWNER AUTHORIZATION My Commission Expires Oct.28,20 a (Where the applicant is not the owner) Joseph Casarona residing at 705 Birch Lr �� Cutchogue do hereby authorize Scott Maskin to apply on my �alf to th,�Town of Southold Building Department for approval as des ribeL;1 in. d , Owner's Signature Date J seph Casarona Print Owner's Name 2 01 BUILDING DEPARTMENT-Electrical Inspector S� �4 TOWN OF SOUTHOLD y:;A =` Town Hall Annex - 54375 Main Road - PO Box 1179 CA, Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 fir rooerr a.southoldtownny.gov— seand aasoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: SUNation Solar Systems, Inc Name: Scott Maskin License No.: 33412-ME email: permifting@sunation.com Address:. 171 Remington Blvd. Ronkonkoma NY_.11779 Phone No.: 631-750-9454 JOB SITE INFORMATION (All Information Required) Name:-Joseph Casarona Address: 705 Birch Road -Cutcho ue NY1.1935 Cross Street: Phone No.: 347-888-7844 Bldg.Permit#: Cj r� 5email: icasarona@mac.com Tax Map District: 1000 Section_: 83 Block:. 1 Lot: 26 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation of solar panels - flat on roof _ Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: _A #Meters Old Meter# . New Service- Fire Reconnect- Flood Reconnect- Service Reconnected - Underground - Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection Formals r 1.! I Graham Associates 256 Orinoco Drive, Suite A Brightwaters,NY 11718 Planning&Design (631)665-9619 { February 20, 2024 i Town of Southold Building Department 54375 Rt. 25 Southold, NY 11971 I i Re: Casarona Residence 1 705 Birch Lane Cutchogue,NY Proposed 9.24 KW PV System To Whom It May Concern, i Please be advised that I have analyzed the existing roof structure at the i above-mentioned premises and have determined that it is adequate to support the additional load of the solar panels and a 140 mph wind load and 20 psf snow load without overstress, in accordance with the following: II The 2020 New York State Uniform Fire Prevention and Residential Building ! Code; Town of Southold Local Code, Long Island Unified Solar Permit j Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020 National Electric Code including ASCE7-16 If you have any further questions, do not hesitate to call. I Sin�ceigrTECl' �J J O U i ^ 0 rch 1 D R rr S TAT I i i Solar Shutdown Device 1 Technical Specifications The Solar Shutdown Device is a Mid-Circuit Interrupter (MCI)and is part of the PV system rapid shutdown (RSD)function in accordance with Article 690 of the applicable NEC. When paired with Tesla Solar Inverter,solar array shutdown is initiated by any loss of AC power. Electrical Nominal Input DC Current Rating(IMP) 12 A Specifications Maximum Input Short Circuit Current(Isc) 19 A Maximum System Voltage(PVHCS) 600 V DC RSD Module Maximum Number of Devices per String 5 Performance Control Power Line Excitation Passive State Normally Open Maximum Power Consumption 7 W Warranty 25 years Environmental Ambient Temperature -40°C to 50°C(-40°F to 122°F) Specifications Storage Temperature -30°C to 70oC(-22°F to 158°F) Enclosure Rating NEMA 4X/IP65 Compliance Certifications UL 1741 PVRSE, UL 3741, Information PVRSA(Photovoltaic Rapid Shutdown Array) RSD Initiation Method PV System AC Breaker or Switch Compatible Equipment See Compatibility Table below Mechanical Model Number MCI-1 —4�_ 0 0 Specifications Electrical Connections MC4 Connector __ __ 250 mm - Housing Plastic M4 Screw Dimensions 125 mm x 150 mm x 22 mm 650 mm 150 mm M8 Bolt (5inx6inxlin) Weight 350 g (0.77 Ib) Nail/ Wood Screw Mounting Options ZEP Home Run Clip __ __ ---- __-- M4 Screw(#10) -- -- ---- ---- M8 Bolt(5/16") Nail/Wood screw H 22 mm t 125 mm- UL 3741 PV Hazard Control (and PVRSA) Compatibility Tesla Solar Roof and Tesla/Zep ZS Arrays using the following modules are certified to UL 3741 and UL 1741 PVRSA when installed with Tesla Solar Inverter and Solar Shutdown Devices.See Tesla Solar Inverter Rapid Shutdown: Module Selection Based on PV Hazard Control System Listing for guidance on installing Tesla Solar Inverter and Solar Shutdown Devices with other modules. Brand Model Required Solar Shutdown Devices Tesla Solar Roof V3 1 Solar Shutdown Device per 10 modules Tesla Tesla TxxxS(where xxx=405 to 450 W, increments of 5) 1 Solar Shutdown Device per 3 modules 7 Tesla Tesla TxxxH (where xxx=395 to 415 W, increments of 5) 1 Solar Shutdown Device per 3 modules Hanwha Q.PEAK DUO BLK-G5 or Q.PEAK DUO BLK-G6+ 1 Solar Shutdown Device per 3 modules Exception:Tesla solar modules installed in locations where the max Voc for three modules at low design temperatures exceeds 165 V shall be limited to two modules between Solar Shutdown Devices. Tesla Solar Inverter and Solar Shutdown Device Datasheet 4 is _ SEG 1n,�tn/w_segsofar'.com �. w , S O L A IR YUKON N Series Half-Cell N-Type TOPCon Monofacial Module 415-430Wp 22.02% Module Power Output Max Efficiency - 2 A: a •'7 ? Key Features ��rl High module conversion ` ° Better temperature efficiency -, coefficient Super multi busbar ■. Low attenuation long technology warranty 7 4-4-1 Superior load Aesthetic appearance capacity USA based liability no Houston,Texas based Insurance. M. company. Warranty Product Certification 100% 99°• 97.4^e Additional Value From Linear Warranty IEC61215:2016; IEC 61730:2016; UL1703; UL61730 95.a'., 0.4 i 93.4% IEC62804 PID 91.4 89.4 IEC61701 Salt Mist 90% 1:4% 1 87.4% 9+ IECG2716 Ammonia Resistance I1:9% 2.4% IEC60068 Dust and Sand I }` IEC61215 Hailstone 80% " Fire Type(UL61730):Type29 0 f s 10 Is 20 25 ao IS014001:2015; IS09001:2015; ISO45001:2018 Years <Years> <Years> Guarantee on product '30Linearpower �� rvCYCLE CE ��� *,FSEC ENERGY COMMISSION material and workmanship output warranty a.r ` �;/ —, mur,ek About SEG Solar SEG Solar is a leading manufacturer of high-performance solar panels for residential,commercial,and utility applications. �• The company,headquartered in Houston,Texas,is cornmitted to providing cost-effective and reliable solar solutions that help ct,istoTiers reduce their energy costs and carbon footprint. Download DM.sheet 7 SEG s o L A R SEG -BG(108Cells) - .__ YUKON N Series SEG-XXX-B -- .- Electrical Charac eristics Module Type SEG-415-BTD-BG SEG-420-BTD-BG SEG-425-BTD-BG SEG-430-BTD-BG Front Front Front I Front Front Front Front Front STC - NOCT STC NOCT STC NOCT STC NOR Maximum Power-Pmp(Wp) 415 1 312 420 I 316 425 320 430 1 324 Open Circuit Voltage-Voc(V) 38.30 1 36.39 3850 1 36.58 1 38.70 36.77 38.901 36.96 Short Circuit Current A-Isc - - ( ) 13.75 11.00 13.83 11.06 13.91 11.13 13.99 11.19 Maximum Power Voltage-Vmp(V) 31.70 29.78 31.90 29.99 ! 32.10 30.21 j 32.30 30.41 - -- - - f - ---- --�-Maximum Power Current-Imp 13.09 10.48 13.17 10.54 13.24 10.59 13.32 10.66 --- - - -- - - - -- - ---l--- - -- ----- 4-Module - -- Efficiency(%) - - ----- 21.25 - _ ------21.51 - _ - 21.76 22.02 Power Tolerance - ---- --------- ------------- -- - Maximum System Voltage 1500V DC Maximum Series Fuse Rating - - - - -__ 30 A - STC radiance IOOD Wlm'module temper tare 25'C AMA 5 NOCT:Imadlance 800w/m'a a.nt temperature 20'C module temperature 45'C wind speed:Im/s Technical Drawing :'Mechanical.Specifications _ mm External Dimension 1722 x 1134 x 30 mm iMOW gMe 4 Weight 20.5 kg E Solar Cells N-TOPCon 182 x 91mm(108 pcs) Front/Back Glass 1.6mm AR coating semi-tempered glass/low Iron E E Frame Black anodized aluminium alloy Junction Box IP68/3 diodes Connector Type PV-CO02-xy e 12 AWG PV Wire (UL) Cable T yp Portrait:400 mm(+)/200 mm(-) r Cable Length Landscape:1200 mm(+)/1200 mm(-) or customized length Mechanical Load(Front) � 5400 Pa 1113 psf 3412mm Mechanical Load(Rear) 2400 Pa/50 psf a E 0 •Referta SEG Installation Man ual for tletails ._`___` _ -"^•-^•.<3 Section A-A 2I1 Packing Configuration 'Refer to SEG nslallaton Manual for details Container 20'GP 40'HO '- --- - -Pieces per Pallet i 36 36 IN Curve Pallets per Container �p"SeTp°gE p I 6 26 to modem 1r,d=100ow/m1 om4-apaw/m' Pieces per Container 216 936 c a o 1,ndent1r d=aoow;m� a 'Temperature Cha�acyterisilcs Pmax Temperature Coefci� t 0.30%/C _ zo' o Wl.geivl °Voc Temperature Coefficient -0.25%/°C a Isc Temperature Coefficient +0.046%/°C -,a 10 - ---- ------ -- - s in-1I111d.9000w/m' Operating Temperature -40"+85°C -c,�iia:mpp °c 4 cc:::: temp--4ei -`ells Temp=aSG Nominal Operating Cell Tern erature(NOCT) 45±2°C - ""amp='°` ° o V°Iing.nc -a ao so www.segsolar.com Specifications subject to technic�I changes SEG_DS_EN_2023V3.0 r,.Copyright 2023 SEG Solar Testa Solar Inverter with Solar Shutdown Device Tesla Solar Inverter completes the Tesla home solar system,converting DC power from solar to AC power for home consumption. Tesla's renowned expertise in power electronics has been combined with robust safety features and a simple installation process to produce an outstanding solar inverter that is compatible with both Solar Roof and traditional solar panels. Once installed, homeowners use the Tesla mobile app to manage their solar system and monitor energy consumption, resulting in a truly unique ecosystem experience. KEY FEATURES • Built on Powerwall technology for 0.5%revenue-grade metering for Solar Renewable exceptional efficiency and reliability Energy Credit(SREC) programs included • Wi-Fi, Ethernet,and cellular connectivity 3.8 kW and 7.6 kW models available with easy over-the-air updates • Designed to integrate with Tesla Powerwall and Tesla App T=5 L Fj Y: } .. •l a:55.rH�,: J r .. as���� •s� - � __ -- _... _.—_'---'--- _ ? �f "1�er�y� yak b March 5,2023 Tesla Solar Inverter Technical Specifications Electrical Specifications: Model Number 1534000-xx-y 1538000-xx-y Output (AQ Output(AC) 3.8 kW 7.6 kW Nominal Power 3,800 W 7,600 W Maximum Apparent Power 3,328 VA at 208 V 6,656 VA at 208 V 3,840 VA at 240 V 7,680 VA at 240 V Maximum Continuous Current 16 A 32 A Breaker(Overcurrent Protection) 20 A 40 A Nominal Power Factor 1 -0.9(leading/lagging THD(at Nominal Power) <5% Electrical Specifications: MPPT 2 4 Input (DQ Input Connectors per MPPT 1-2 1-2-1-2 Maximum Input Voltage 600 VDC DC Input Voltage Range 60-550 VDC DC MPPT Voltage Range 60-480 VDC1 Maximum Current per MPPT(IMP) 13 Az Maximum Short Circuit Current per 17 Az MPPT(Isc) Maximum current. Y Where the DC input current exceeds an MPPT rating,jumpers can be used to allow a single MPPT to intake additional DC current up to 26 A IMP/34 A Isc. Performance Peak Efficiency 98%at 208 V 98.4%at 208 V Specifications 98.1%at 240 V 98.6%at 240 V CEC Efficiency 97.5%at 208 V 97.5%at 208 V 97.5%at 240 V 98.0%at 240 V Allowable DC/AC Ratio 1.7 Customer Interface Tesla Mobile App Internet Connectivity Wi-Fi (2.4 GHz,802.11 b/g/n), Ethernet', Cellular(LTE/4G)4 Factory-Installed Revenue Grade Meter Revenue Accurate(+/-0.5%)3 AC Remote Metering Support Wi-Fi(2.4 GHz,802.11 b/g/n), RS-485 Protections Integrated arc fault circuit interrupter(AFCI), Rapid Shutdown Supported Grid Types 60 Hz,240 V Split Phase 60 Hz,208 V Wye 3 Applicable to Tesla Solar Inverter with Site Controller(1538000-45-y)only. 4 Cellular connectivity subject to network operator service coverage and signal strength. Tesla Solar Inverter and Solar Shutdown Device Datasheet 2 O 5w 4-'"p��:��6r- 4-3�Y Industry leading Wire .. Mounts available for all Management Solutions roof types All SnapNrack Module Single Tool Installation rot. & Accessories are compatible with both rail profiles Start Installing Ultra Rail Today V SnapNrack A sleek, straightforward rail solution for mounting solar modules on all roof types. Ultra Rail now features one rail profile, UR-45, a lightweight rail profile that's suited for all geographic regions, with varying span capabilities. UR-45 Rail maintains all the great features of SnapNrack rail like snap-in module clamps and an open rail channel for.integrated wire management. The Ultra Rail portfolio features multiple roof attachment sealing technologies for all install preferences. NEW! UltraFoot Roof Attachments • Features SpeedSealT""+ Technology, a pre-installed butyl pad for easy peel & stick installation • The only single lag roof attachment with butyl sealing available • UltraFoot available in (3) configurations to accomodate rafter & deck mounting based on DeckAnchorTM or wood screw install preferences • All UltraFoot designs feature new Flip Clamp Mount that centers load over fastener & creates an easier snap-in experience with UR-45 Rail = The Entire System is a Snap to Install • Ultra Rail Mounts include snap-in brackets for attaching rail • Ultra Rail Mid Clamps & End Clamps are one-size- fits-all universal clamping height • Universal End Clamps & snap-in End Caps provide a clean look to the array edge Unparalleled Wire Management • Open rail channel provides room for running wires resulting in along-lasting quality install • Module clamps eliminate bolt interference in the rail channel creating more space for wire management • Industry best wire management offering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits & Conduit Clamps • System is fully bonded & listed to UL 2703 Standard DESCRIPTION: DOC NUMBER: SNAPNRACK, TDS, UR-45 RAIL SNR-DC-01420 SnapNrackoDRAWN BY: PART NUMBER(S): H.WULFEKOETTER SUNRUN INSTALLATION SERVICES INC. 232-10095, 232-10096, 232-10097, 232-10098, REV: DATE: 226 BUSH STREET,SUITE 1400.SAN FRANCISCO,CA S4104 USA PHONE(677)732-2660.CONTACT@SNAPNRACK.COM THEINFORM T!ONINMISDR WNO ISCONFIDENTIALANDPROPRIETARY.ANY UNITS: IN, LB, DEG [MM, KG, DEG] SHEET: 1:1 3/6/2024 REPROOULR ON,OISCUJSURE,OR USEMEREOFIS P0.0NIS TEOWMOUT ME VYRITfEN CONSEW OF SUNRUN SOUM LLC. UR-45 RAIL PROPERTIES SKU FINISH RAIL LENGTH WEIGHT (lb) 232-10095 MILL 172 in 5.55 232-10096 BLACK 172 in 5.55 232-10097 MILL 94 in 3.03 232-10098 BLACK 94 in 3.03 .740 .895 SECTION PROPERTIES A 0.319 in2 Ixx 0.134 in4 .855 IYy 0.121 in4 Sx (TOP) 0.152 in3 Sx (BOT) 0.156 in3 Sy (LEFT) 0.164 in3 Sy (RIGHT) 0.164 in3 MATERIALS: 6005-T5 ALUMINUM DESIGN LOAD (LBS): N/A ULTIMATE LOAD (LBS): N/A TORQUE SPECIFICATION: N/A FT-LBS CERTIFICATION: UL 2703, FILE E359313 WEIGHT (LBS): 5.48 - 5.62 (172 in), 2.96 - 3.10 (94 in) Tesla Solar Inverter Technical Specifications Mechanical Specifications Dimensions 660 mm x 411 mm x 158 mm (26 in x 16 in x 6 in) 00 00 00 40 LR ao 00 00 00 00 00 660 00 mm 0 o0 �OC:3158 00 N 411 mm ►I �mm I I mm Weight 52 Ibs Mounting Options Wall mount(bracket) s Door and bracket can be removed for a mounting weight of 37 lb. Environmental Specifications Operating Temperature -300C to 450C(-220F to 1130F)6 Operating Humidity(RH) Up to 100%,condensing Storage Temperature -30°C to 70°C(-22°F to 158°F) Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Rating Type 3R Ingress Rating IP55(Wiring compartment) Pollution Rating PD2 for power electronics and terminal wiring compartment, PD3 for all other components Operating Noise @ 1 m < 40 db(A) nominal, <50 db(A) maximum 6 For the 7.6 kW Tesla Solar Inverter,performance may be de-rated to 6.2 kW at 240 V or 5.37 kW at 208 V when operating at temperatures greater than 45°C. Compliance Information Grid Certifications UL 1741, UL 1741 SA, UL 1741 SB, IEEE 1547-2018, IEEE 1547.1 Safety Certifications UL 1741 PVRSS, UL 169913, UL 1998(US), UL 3741 Emissions EN 61000-6-3(Residential), FCC 47CFR15.109 (a) Tesla Solar Inverter and Solar Shutdown Device Datasheet 3 lJl/l� PLAN KEY KEY PROPOSED RESIDENTIAL - �-ETJi1'CE DISLSRJ.ELT PV1-0 COVER SHEET ®•suPwxsmEcoti•;EcrAu PHOTOVOLTAICAl-1 PARTIAL ROOF PLAN SYSTEM o•AiTrovAncTTursrERsnnnt A1-4 ROOF ACCESS PLAN E3 °S&MTM S1_1 STRUCTURE ®-MAMIS°`MPANEL 10-SUB PAN-L SUNATION SOLAR SYSTEMS NYSERDA 4355 E1-1 ONE-LINE DIAGRAM a 171 REMINGTON BOULEVARD INSTALLER E2-1 PV LABELS ®-E?PmEncomaim o RONKONKOMA,NEW YORK 11779 NUMBER G1-1 PV PHOTOS ®.PuTLPHW0XL-1= °� m Casarona Residence ®.EZGT=V0=ET T 705 Birch Lane,Cutchogue, NY 11935 B-ET IAW RAW z 0 �-sE1LSEco;susrno:�eo+TroR � ® Drawn By:M. Danziger-02/14/2025 — —------ --------- —------ --. •TESLA LTATEVAY A U I c 6 ®-nSAPO:.FRV7AlL 5 �O ARCH/`� ®-EausEnsrsTEmco:naoum A ®.v,vw SEmPeATrEw L D� G'1A ©-GV ERAM4 PAn 4yy ©-BAGW tl LCPDS CEnEI ! • Y `V/ \J o-MfrP E L11 --E KTEMM WCAU3N �L TSTFLODRL➢CATM .-BARMRLCCATPJN - --� �` - ----- ---- - - -—= .QARMELDCA=I r v Town i e s�rhi N�s received the enclosed document for minimum acceptable APPROVED AS NOTED plan subm emenls of the town as specified in the building and/or Residential Code of the State of New York. This review does not guarantee compliance with that B.P 5 I"1 q5 code. that responsibility is guaranteed under the seal and signature of the New York State licensed design professional of record. That seal end signature has been PROPOSED PV SYSTEM Interpreted as an attestation that,to the best of the licensee's belief and tnformation T w, the work in this document is: Module Type/Gly: (22)SEG-420-BTD-BG Div 8 —jf • Accurate ! • Conforms with governing codes applicable at the time of submission Module Dimension: 67.8"x 44.65"x 1.18" • Conforms with reasonable standards of practice and with view to the NOTIFY BUILDING DEPARTMENT AT safeguarding of life,health,property and public welfare is the responsibility of the Module Weight/PSF: 52.91 lbs/2.51712654614653 PSF 631-765-1802 8AM TO 4PM FOR THE ncensee. Inverter: (1)Tesla Solar Inverter 7.6kW VVVIVVI\IVIV FOLLOWING INSPECTIONS: structural Statement System DC Rating: 9.24 kW \ �� /VVV V v /\ /V V�.! FOUNDATION-TWO REQUIRED ' System AC Rating: 7.68 kW/AC V V FOR POURED CONCRETE ' The existing structure is adequate to support the new toads imposed by the photovoltaic module system including uplift and shear. The existing rafter sizes I and dimensions conform to RC-NYS 2020 table 8802.4.1(2)-Rafter Spans. Aurora Estimated AC Production: 9,611 kWh/yr p�PaoPOSIDPY ROUGH-FRAMING&PLUMBING M'7PJiEs INSULATION PV Notes `�PwAE� FINAL-CONSTRUCTION MUST 1. This PV system has been designed to meet ati current and applicable fire f prevention setback pathways per 2020 NYS Residential Code. Proper ground —�' E COMPLETE-FOR-C.O.— clearance,roof access points,access pathways and ventilation systems shall be i — ----- -- -- -- - - - .O'-- provided where necessary. An in depth description of each applicable code SERVED FOR/�i-1,i: reference and exception for any codes Is depicted on the PV-1 plate of this — — BE COMPLETE -- —— ALL CONSTRUCTION SHALL MEET THE drawing package. REQUIREMENTS OF THE CODES OF NEW i 2' solaar eq ipmentno more than a single layer of roof covering in addition to the YORK STATE, NOT RESPONSIBLE FOR 3. Installation of solar equipment shall be flush-mounted,parallel to and no more than 5-Inches above the surface of the roof. I i DESIGN OR CONSTRUCTION ERRORS 4. Weight of the Installed system shall not exceed more than 5-psi 5. Any plumbing vents are not to be cut or covered for solar equipment installation. Any relocation elo tion or modification of the vent requires a plumbing permit and FULL HOUSE ROOF PLAN f Inspection. SCALE N.T.S. ! This PV system has been ded to meet the minimum design standard for building COMPLY WITH ALL CODES OF and other structures of the AVEs 7-16 and the 2020 New York State Residential Code. NEW YORK STATE&TOWN CODES AS REQUIRED AND CONDITIONS OF Additional PV1 0 • COVER PAGE JOB# 24893 solnllol��l�a Certification S UiliO1DTMUPUWNINGBOMO May Be Required. REVISION # N/A - SUNATION K ' t=r;E RGY' REVISED BY NIA ELECTRICAL so INSPECTION REQUIRED i ' � I i z INVERTER #1 RIDGE AF;C STRING 1 30,_2„ ROOF 1 \g�P L K D�/��`� RIDGE CAPPING to (TYP.) 6" 1k Y t MCI M I M 1 Sri OFtA i s -1I�� S 12'-172y 7' SUNATION SUNalion Solar Systems 171 Remington Blvd. Ronkonkoma,New York 11779 (631)-750-9454 MCI M I M 1 N SER STALLE 4 3 5 5 tNTALLt�i NUMBER JOB NUMBER INVERTER #1 GUTTER HOUSE 24893 STRING 2 17'-9/2' ROOF 2 l 10 ROOF AREA .i r+ 3w Y, � s.. �.,- •ram;:- - co Ln CMINVERTER #1y � � $ r N STRING 3 za z { . , �� az M 1 2 :2, 0 m x !ram 3 O PHOTOVOLTAIC MODULE U. 26 o. to tv LO GUTTER f Attachment Spacing:Portrait Attachment Spacing:Landscape Roof# Roof Description Modules Azimuth Tilt Pitch Interior Edge Corner Interior Edge Corner i 1 Southeast Roof 16 132° 320 8.5112 48" 32" 16" 64" 48" 48" I 2 Southeast Roof 6 1320 150 4/12 32" 16" 16" 64" 48" 32" 2 I 1/4"=1'-0" i Alml PARTIAL ROOF PLAN i a l I I SOLAR ENERGY SYSTEMS (NY) R324.6 Roof access and pathways. Roof access,pathways and �(ZED A C,r),T setback requirements shall be provided in accordance with Sections �l- K R324.61 through R324.6.2.1. Access and minimum spacing shall be �� .Z.�'' D�4-� required to provide emergency access to the roof,to provide pathways V � to specific areas of the roof,provide for smoke ventilation opportunity areas and to provide emergency egress from the roof. Exceptions: T _ ` O 1. Detached, non-habitable structures, including but not limited to z �-4� 029 detached garages, parking shade structures, carports, solar o trellises and similar structures, shad not be required to provide n O y i roof access. o 2. Roof access, pathways and setbacks need to be provided m where the building official has determined that rooftop , operations will not be employed. � o 3. These requirements shall not apply to roofs with scopes of two z SUNATB®N units vertical in 12 units horizontal(17-percent slope)or less 1. t,wcxY SUNation Solar Systems [NY] R324.6.1 Pathways. Not fewer than two pathways,on separate m 171 Remington Blvd. roof planes from lowest roof edge to ridge and not less than 36 inches °� Ronkonkoma,New York 11779 (914 mm)wide,shall be provided on all buildings. Not fewer than one 0 (631)-750-9454 E pathway shall be provided on the street or driveway side of the roof. o For each roof plane with a photovoltaic array,a pathway not less thanDA 36 inches(914 mm)wide shall be provided from the lowest roof edge m r.+sP ce) NYSER INSTALLER 4355 to the ridge on the same roof plane as the photovoltaic array, on an INrALLER (EXT) NUMBER{ adjacent roof plane, or straddling the same and adjacent roof planes. Pathways shall be over areas capable of supporting fire fighters JOB NUMBER accessing the roof. Pathways shall be located in areas with minimal obstructions such as vent pipes, conduit, or mechanical equipment. 24893 Pathways on opposing roof slopes shall not be located along the same plane as the truss, rafter,or other such framing system that supports the pathway. i Exception: 1. Access pathways shall not be required on roof slopes containing photovoltaic modules, panels, or an array where the opposing rn o E or adjacent roof slope is an access roof. O Z v Z Access Roof-A roof surface that: 1. Can be accessed from the ground by the fire service. 2. Is capable of providing fire service access to the ridge or peak ILL [r ¢U N of an opposing or adjacent roof surface that contains A; (E)Cn Z o photovoltaic modules,panels,or an array. IDSCI INV UJI Ms ro a 3. Is relatively free of vents,skylights,conduits,mechanical ,K equipment and other such obstructions. (c) U�_ c 4. Does not contain photovoltaic modules,panels or an array,or is m 3 I a single ridge roof where the maximum edge to edge width of the photovoltaic panel system does not exceed 33 percent of the ridge length. £- [NY] R324.6.2 - Setback at ridge. Photovoltaic arrays shall not be located less than 18 inches(457 mm)from a horizontal ridge. V V V V V V I [NY] R324.6.2.2 - Emergency escape and rescue opening. Panels I and modules installed on dwellings shall not be placed on the portion of the roof that is below and emergency escape and rescue opening. \ /V\ /V v I A pathway not less than 36 inches(914 mm)wide shall be provided to v v 1 a the emergency escape and rescue opening. i (16)PROPOSED PV MODULES f N.T.S. I i (6)PROPOSED PV MODULES 1 I Al =4 ROOF ACCESS PLAN 4 i Typical Attachment Method o A oCt,a ,ti�T� LK RIDGE SNAP'N'RACK ULTRA RAIL PHOTOVOLTAIC 12'-1.5" I (P 2Sa� 4. MODULE SNAP'N'RACKSPEEDS AL �y L-FOOT F VA 3/4"MODULE SPACING ' \ BETWEEN ROWS AND INSTALLERS TO APPLY SEALANT ON COLUMNS(TYP.) BOTTOM SEALANT RING ! r �+ `T p USE-NPC Solar Seal#9D0 (1)LAYER COMPOSITE � SUN/\1 IO1 VI SHINGLE &C fT�^`i SUNation Solar Systems 6116-X5.0 171 Remington Blvd. RAIL SEALING LAG SCREW / Ronkonkoma,New York 11779 FASTENED TO RAFTER / (631)-750-9454 / t RAFTER !/ / N INSTALLER 4355 2"x 6" 24° O.C. // / NUMBER i PLYWOOD DECKING JOB NUMBER "P) WOOD FRAMING 24893 (TYP.) SOFFIT ATTACHMENT TYPE APPLIED TO-ROOF'TYP' . EXTERIOR WALL to LID ROOF SECTION (TYP.) 0) CM SCALE: N.T.S. r N o CM SOLAR MODULE FRAIJE G r 0 NOTE:314'SPACING t i BMiEEN MODULE ROWS Q Z L AND COLUMNS. (n Roof# Rafter Size Spacing Max Span Material Layers Sheathing a) -� rn 1 2"x 6"124"O.C. 9'-1.5" Composite Shingles 1 Tongue and Groove. 45a MR)END CLMM z (0 V Q 2 2"x 6"/24"O.C. 7'-4.5" P g 1 Plywood . ` ♦ HEIGHT ADJUSTABLE 2 Composite Shingles PI ood S ♦ L-FOOT(TYP.) FW- 05 � .� SNAP W RAcx U t m •� I ULTRA RAIL i T7OTTr` ,� (TYP.) . i m 5.5' i �—HEIGHT OFF OF O L ' ROOF SURFACEST- i i PEST AND Typical Module DEBRISIBARRIER-CUTAWAY Side Profile FORCLAwrr I i CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA -TABLE R301.2(1) WIND DESIGN ICE BARRIER SUBJECT TO DAMAGE { j SEISMIC DESIGN WINTER DESIGN MEAN ANNUAL � GROUND SNOW TOPOGRAPHIC WIND BORNE DEBRIS CATEGORY TEMPERATURE UNDERLAYMENT FLOOD HAZARD AIR FREEZING INDEX TEMPERATURE LOAD SPEED(MPH.) EFFECTS SPECIAL WIND ZONE ZONE WEATHERING FROST LINE DEPTH TERMITE REQUIRED I E PLANS S I 20 PSF 140 B YES 2 8 SEVERE T-0' MODERATE TO 15 DEG NIA EEXM1 NER 599 51 STRUCTURE . 1 I i Q,EL p2—8A11 / Uaty Service 91T.. 1 Testa DC Series String wf Tesla Mid-Circuft Interrupter(s)"MCI"(typ.) Ed —� PSEO U55y M.4,1 P - Accata�t0-9MSIRM . + TESLA INVERTER Me-I-98404617 rre *y (n�a ,� 1 0Y `l SUNATION Testa MCI-2 .J Module J-Box(typ.) V � c�1dEl�C'1` tDISTFL SUNation Solar Systems �1 171 Remington Blvd. P,v Modute(typ.) I Ronkonkoma,New York 11779 _ (631)750.9454 EGO Attached To Rag(typ.) INVERTER dt BUS R RATING RA 122 TESLA-MODEL1538000-xx-y[240Y) O I I NYSERDA INVEATER-UNGROUNDEOlYiTH 10DA INVERTER(S)OUTPUi CIRCUIT=32.QOA 200A i [NTEGRAL DC ISOLATOR SWITCH INSTALLER 4355 120240VAC.1-PHASE O MAIN 132.ODAx125%=40.00A I MAIN NUMBER i MAX 32 AMP 4D.00A+10DA-140.ODA 225Ax 120%=27 140.00 0A JOB NUMBER A<_270A ` CONDUIT AND CONDUCTOR SCHEDULE 270A-IOD AR N=1 =270A 24893 TAG CONDUCTOR CONDUIT RUN t 1170A-1016=136=I7DA DC STRING#1 / �.J 170A x�=138A I TYPE GAUGE QUANTITY TYPE SIZE LENGTH DC STRING92 i 0 The maximum inverter output current is 136A j 1 PV Wire 10 8 NIA NIA 15' DC STRING#3 40A 1 per NEC 2017705.12(s)(2)(3)@) EGG 6 3 NIA NIA I& EGC INPUT OUTPUT DC AC MAIN J 2P4E Backfeed amount isWitedby the Main OCPD. 2 MC Cable 10 8 NIA NIA 20' I Ur EGC 6 3 NIA NIA 20' e2t3 G G G Pv haddeed bream to be insrsffid G DC STRING AIC GARAGE h1A1N at Me � 12 t3Ofthe�{5; 10 HOME AJ SERVICE PANEL ; 3 THWN-2 10 8 RMC 1AD° 25' ROOF ATTIC EXTERIOR INVERTER DISCONNECT SERVICE PAN Pt1 EGG 10 1 RMC 1.00" 25' 4 5 4 THWN-2 8 3 PVC SCH.80 1.25' 15' � C11 EXTERIOR lr7 EGC 10 1 PVC SCH.80 1.00' 1 15' j DISCONNECTING MEANS r O 5 THWN-2 8 3 PVC SCH.80 1.25" 5' BUILDING BUILDING EGC 10 1 PVC SCH.80 1.00- 5' GROUNDING GROUNDING r ELECTRODE ELECTRODE z U Z N C C 0) O 0) 3 1 ) t Ir RLL Ca i z C V co { Circuit# PV Module Qty. Micro-Inverter Gty. Maximum AC Operating CurrentCU f 1 SEG-420-BTD-BG 8 2 SEG-420-BTD-BG 8 Tesla Solar Inverter 7.6kW 1 32 Aco 3 SEG-420-BTD-BG 6 LO h Q } I I i i Maximum AC Operating Current(Total) 32 A E1 =1A ONE-LINE DIAGRAM i I I i LABEL LOCATION: LABEL LOCATION: ^-` . ,p I-C� ■ • • • CONDUITS: AT EVERY SEPARATION BY ENCLOSURES/WALLS/PARTITIONS/ — • •• • MAIN DISCONNECT PANEL: 1 OF EACH AT BUILDING MAIN DISCONN , Y/�. CEILINGS/FLOORS OR MORE THAN 10'. PANEL SPLICE/COMBINERS:1 AT ANY COMBINER BOX/F USED NEC 2017 705.10 � s Z v a. NEC 2017 690.31(G)(3)/NEC 2017 690.33(E)(2) Second Disconnect It _ cated next to Meter Pan WARNINGC1 � •-S�� �0 I DO NOT DISCONNECT - - -- ---- - --' UNDER LOAD -- = :---- �; LABEL LOCATION: MAIN DISCONNECT PANEL: 1 OF EACH AT BUILDING MAIN SERVICE AT This building is equipped vnth an i ; DISCONNECT PANEL AND UTILITY METER J`SUN I®N -------- ---- - ------- - - - - ----- Interconnected Electric Power LABEL LOCATION: Production Source NEC 2017 705.10 SUNalion Solar Systems l • • 171 Remington Blvd. OPERATINGVE THIS TAG REM tMIMUM AC AC DISCONNECTING MEANS: 1 AT EACH AC DISCONNECT,COMPLETE VOLTAGE f ' • , , Ronkonkoma,New York 11779 ' Source Type: (631)-750-9454 AND CURRENT VALUES ON DISCONNECT LABEL. NOMINAL AC O.ERATING Solar Photovoltaic DsconnedisLocated: Interior NYSERDA 4355 NEC 2017 690.54!NEC 2017 690.13(B) INSTALLER Basement_ Garage:_ Euterior._ NUMBER Front_ Rear— LH Side:_ i RHSde:_ Other Location: JOB NUMBER i SUNatlon Solar Systems Service Disconnect w 750-9454 24893 j wwwsunalion.com ` ELECTRIC SHOCK HAZARD -----e -- DONOTTOUCHTERMINALS --------- - -----------------. . Primary Service Disconnect TERMINALS ON BOTH THE LINEAND LOAD SIDES MAY BE ENERGIZED LABEL LOCATION: Located Main Service Panel IN THE OPEN POSITION PHOTOVOLTAIC PHOTOJOLTA'C6!OWLESPSCDJCEDCVDLTAV-- INVERTER/AC DISCONNECT/DC DISCONNECT: 1 AT EACH OF THE cHERTHErAtr�EaTosUraxTr ■ NOTED LOCATIONS• ■■ -- SHUTDOWN NEC 2017 690.56(C)(1)(a) � In N r O r N DISCONNECTPV SYSTEM DC LABEL LOCATION: SOLAR SYSTEM EQUIPPED �, z .• DC DISCONNECT: 1 AT EACH INTEGRATED DC DISCONNECT. COMPLETE VOLTAGE Z U N _NTH RAPID SHUTDOWN r- ? O 0 AND CURRENT VALUES ON DC DISCONNECT LABEL. __ ._____...._,._a_ _ � � � � } OPERATING VOLTAGE, i p NEC 2017 690MAXIMUJA SYSTEM VOLTAGE, .53/NEC 2017 690.13(B) ! r�, 0 4 SvvffcHMTHE OFPPOSnIONTO R. ' cr •R ' SHORT CIRCUIT CURRENT. SHUTD(YANPVSYS I LL 0 I ANDRFDUCFTHE I; Z C V SHOCKH47ARD (, W NIARRAY LI Lt I— c0 C I! N its co i C ELECTRIC SHOCK HAZARD ELECTRIC SHOCK HAZARD LABEL LOCATION: m 3 to COGEN THE DC CONDUCTORS OF THE DC CONDUCTORS OF Disconnect1 AT DER Disconnect Switch/Isolator ^ l� PSEG SGIP Chapter 7-7.2 DER Isolation Switch/Isolation � THIS PHOTOVOLTAIC SYSTEM THIS PHOTOVOLTAIC SYSTEM Switch I ARE UNGROUNDEDAND ARE UNGROUNDEDAND f MAY BE ENERGIZED MAY BE ENERGIZED 4 i i i E2= 1 PV LABELS l i f • �D Ah'C L KDCG/�� n Z. �'--!- — -- --=� r ENERGY r ' _— — SUNation Solar Systems 7-r 171 Remington Blvd. Ronkonkoma,New York 11779 (631)-750.9454 NYSERUA INSTALLER 4 355 NUMBER JOB NUMBER t� 24893 ARRAY LOCATION(S) ARRAY LOCATION(S) SATELLITE IMAGE VIA GROUND VIA ROOF � u') C'V O � CV s tv Z �7 J►'� Z U CV _ C O O O O � cc O Z c: ' W O H tb O R3 J t - m 21 SOUTH VIEW PROPOSED PV EQUIPMENT EXISTING UTILITY METER VIA ROOF LOCATION AND MDP ! G 1 1 - PVPHOTOS I _ ■ p tip, , \ • � a Y � r ,war 1 1 � mM � s i y.. Y + r I., g i R PHOTOVOLTAIC SY, bon Q AC DISCONN • OPERATING VOLTAGE240.0 'RATING CURRENT A v y - ' 4 SUB PANEL Jl - - SOLAR MAO. r..h c , J - r 1 I ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS - TERMINALS ON BOTH THE LINE AND <j N- . LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION I 9U181 — o►san S'D AI l(I\9 �uvN�olssdnayl w sdnay� I � "04S Sd )41 4. I it Yf _ In -I 0 N C O J TURN OFF POWER SUPPLYING THIS Na•e. .+ PANNEAU DE DISTRIBUTION EQUIPMENT BEFORE EXTERIEUR, WORKING LEV1 6�® TYPE 3R-PROTEGE LAUM N q OINE LOAD CENITElk PANNEAU: tLECTRIQUE DE CET TT any,III 1 225 A MAX(VOIR LA VALEUR APPAREIL AVANT DE NOMINALE AU DISJONCTEUR TRAVAILLER A RAtMDI �WAPAL) L'INTERIEUR A MAX W MAN WMAI" WITH 1201240 V CA,60HZ-1PH•3-FILS;OU FOR REPAIRS OR CONSULTER UN ENTREPRENEUR VAC'�L,OR pBY/120 V CA.60 Hz,3-FILS,(DU ELECTRICAL CALL AN ELECTRICIEN OU UN ELECTRICAL CONTRACTOR ELECTRICIEN POUR TOUTE r2VOVAIC,MA&VMRE(FROM 3-PH,* RESEAU A 3-PH,4-FILS). OR ELECTRICIAN. REPARATION OU MODIFICATION. nmlL— ORp BREAKER RATINGS PER STAB;140 AMP. ml JE LEVITON TYPE LB CIRCUIT BREAKERS.MAX SUM %OFTHE RATING OF THE MAIN BREAKER OR BRANCH BREAKER. IE Mk MLW CONTINUOUS LOAD NOT TO EXCEED BO%OF THE p LOAD CENTER IS INVERTIBLE FOR BOTTOM FEED APPLICATIONS. URS DE TYPE LB DE LEV TON.VALEUR NOMINALE MAXIMALE COMBINEE DES DISJONCTEURS POUR CHAQUE MJSIER DES dgJONCTE CONTINUE N ' , I �JSAE :140 AMP.LA CHARGE MAXIMAIE E PEUT DEPASSER 80%DE LA VALEUR NOMINALE DU DISJONCTEUR PRINCIPAL. N SECOND CE CENTRE DE CHARGE EST INVERTIBLE POUR INSTALLATION AIIE NEC ALIMENTATION PAR LE RAS. pW USED AS SERVICE EQUIPMENT,ANY UNUSED NEUTRAL HOLES MAY BE USED FOR EQUIPMENT GROUNDING IN THE COMBINATION MCATED FOR EQUIPMENT GROUNDING BAR TERMINALS. HOVE THE BOX BONDING SCREW ONLY WHEN REQUIRED BY THE ELECTRICAL INSPECTION AUTHORITIES, RES ON EA LA TERRE DEL tQO PEMENTIDANS LA OMBIRNAISONOINDIQUEE POUR ILEST ERMIINAUX DEISMISE A LA TERRE DES EQUIPEMENTS .BE gNMR LA VIS DE LIAISON DE BOITE SEULEMENT QUAND EXIGE PAR LES AUTORITES COMPETENTES EN INSPECTION ELECTRIQUE. r—A ER HANDLE IN MID-POSITION INDICATES BREAKER IS TRIPPED.TO RESTORE SERVICE,MOVE HANDLE TO EXTREME"OFF", EN TO'ON', ,POIGNEE DU DISJONCTEUR EN POSITION INTERMEDINRE INDIQUE QUE LE DISJONCTEUR EST DECLENCHE.POUR RESTAURER UJMENTATION,FORCER LA POIGNEE EN POSITION aOFF.,PUTS SUR ON., INSULT LEMON CATALOG NUMBER FOR PANEL 70VER ASSEMBLY. BACKFED PREPKER REQUIRES HOLD DOWN KIT-CATALOG$LITLK )NSULTER LE NUMERO DE CATALOGUE DE LEVITON POUR I.E COUVERCLE D'ASCEMBLAGE DU PANNEAU.LES DISJONCEURS A JMENTATION ARRIERE REQUIERENT LINE TROJE SC M JPPORT SPECIFIQUE-NO DE CATALOGUE:LITLK - IUSED CIRCUIT BREAKER OPENINGS MUST BE CLOSEL MTN FILLER PLATES(CATALOG NUMBER:LFPLT) i9 OUVERTURES DU DISJONCTEUR NON EXPLOITI%S^nN,-NTT ET.E FERMEES AVEC DES PLAQUES DE REMPLISSAGE UMERO DE CATALOGUE:LFPLT) - I )R ADDITIONAL COMPATIBLE ACCESSORIES CONSUL"I 'Or EVITON CATALOG NUMBERS BELOW: REPORTER AU TABLEAU DES NUMERRS DE CATALOG:FL 1r.V,1 ON CI-DESSOUS POUR PLUS WACCESSOIRES COMPATIBLES: I CATALOG$ DESCRIPTION — FITERRETROUSSEIBA_RRE DESCRIPTION LFPLT BRANCH BREAKER F '_LER PLATE REM PLISSAGE DISJONCTEUR SECONDAIRE LBHPL BRANCH HANDLE PADLOCK DEVICESERRURE DE POIGN E DE BRANCHE LMHPL MAIN HANDLE PADLOCKDCVICE� SERRURE DE POIGN E PRINCIPALE LDRLK DOOR LOCK KIT TROUSSE DE EQUIPM ENT OE VERROUILLAGE DE PORTE LL630 MAIN LUG KIT TROUSSE PRINCIPALE DE BOULONS LTCVR MAIN BREAKER SERVICE BARRI'1 SERVICE DE DISJONCTEUR PRI^'CIPAL LGBKT GROUND BAR KIT SSEIBARRE 0E MALT LLPHN REPLACEMENT LOAD LUGS LLPHN BOULONS CHARGE DE REMPLACEMENT OX-B31Cr,R"0,01 � Raiy�t — LEVIl®, ff- SUB ANEL R7 ��OELIA31 Wa "I Will 111111 t'�` s:bt o$����1�4e.�b�le � • zmo I az c SUB PANEL .f {may e J l I j SOLAR a1 g _ �1