HomeMy WebLinkAbout51565-Z ho�aof s°�ryolo Town of Southold
* * P.O. Box 1179
53095 Main Rd
CO Nr,� Y� Southold, New York 11971
CERTIFICATE OF OCCUPANCY
No: 46963 Date: 04/09/2026
THIS CERTIFIES that the building SOLAR PANEL
Location of Property: 780 Legion Ave Mattituck, NY 11952
Sec/Block/Lot: 142.-2-13.1
Conforms substantially to the Application for Building Permit heretofore;filed in this office dated: 11/18/2024
Pursuant to which Building Permit No. 51565 and dated: 01/16/2025
Was issued, and conforms to all of the requirements of the applicable provisions of the law.
The occupancy for which this certificate is issued is:
Roof mounted solar panels to an existing single-family dwelling as applied for per
manufacturers specifications.
The certificate is issued to: Gabriel Kochmer ,, Marcia Bockol
Of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL:
ELECTRICAL CERTIFICATE: 110182 5/13/25
PLUMBERS CERTIFICATION:
A orized igiuture
p�;asorr� � TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 51565 Date: 01/16/2025
Permission is hereby granted to:
Gabriel Kochmer
13 Peacock Path
East Quogue, NY 11942
To:
Install roof mounted solar panels to an existing single-family dwelling as applied for per
manufacturers specifications. Additional certification may be required.
Premises Located at:
780 Legion Ave, Mattituck, NY 11952
SCTM# 142.-2-13.1
Pursuant to application dated 11/18/2024 and approved by the Building Inspector.
To expire on 01/16/2027.
Contractors:
Required Inspections:
Fees:
SOLAR PANELS $100.00
CO-RESIDENTIAL $100.00
ELECTRIC -Residential $125.00
Total $325.00
Building Inspector
NASSAU ELECTRICAL
S U F F 0 L K INSPECTORS
19
159 Route 25A, Building 1 Suite B
Miller Place, NY 11764
Telephone:631495 8136 - Fax:631509 4538 - E-Mail:Requests@SuffolkBEI.com
CERTIFICATE OF ELECTRICAL COMPLIANCE
Applicant: Harvest Power LLC Certificate No.: 110182
Rough In Inspection Date: Final Inspection Date: May 13,2025
Application No.: Building Permit No.: 51565
County Tax Map No.: 142 2 13.1
This Certificate of Electrical Compliance is limited to the inspection and compliance of electrical equipment and/or work described
below,installed on behalf of the applicant named above,located at the premise of and not after the final inspection date above:
Owner: Marcia Bockol
Site Location: 780 Legion Avenue,Mattituck, NY 11952
Owner's Address(if different):
II
Residential 12 indoor 0 Basement 0 Service D Shed
C3 Commercial 12 Outdoor 0 First Floor 0 Pool C3 Hottub
0 New 0 Renovation 0 Second Floor 0 Attic (D Garage
0 Addition 0 Survey 0 PV Solar C)Generator 0 conversion
0 Signs 0 Battery Storage Other:
INVENTORY
Single Phase Heat Duplex Recpt Ceiling Fixture Dual Func Breaker
Three Phase HotWater GFC1 Recpt Wall Fixture Smoke
Main Panel AC Cond Single Recpt 0 Recessed Fixture CO Detect
Sub Panel AC Blower Range Recpt LED Lighting r Smoke CO Combo
Transformer Appliance Ckt Dryer Recpt Emergency Time Clock
Disconnect Switches Twist Lock Exit Fixtures Pumps
GFC]Breaker Heat Pump Electric Heat Pool Luminaire Exhaust Fan Other Equipment:System Size:4.6 kW City:10 Desc:REC REC460AA Qty:10 Desc:ENPHASE ENERGY lQ8X-B0-M-LlS
The electrical work and/or equipment described above were inspected and was found to be in compliance with local,
state and national electrical code requirements and this office.
Applicant: Harvest Power LLC License No.: ME-68518
Date Printed: May 13,2025
Inspected By: Joe Coppola
fl
Signature:
souryo
# TOWN OF .SOUTHOLD BUILDING DEPT.
u 631-765-1802
INSPECTION
[ ] FOUNDATION.1 ST/ REBAR [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING
[ ] FRAMING /STRAPPING [ .FINAL
[ ] FIREPLACE & CHIMNEY. [ ] FIRE SAFETY.INSPECTION
[ ] .FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL
REMARKS: ��� /� � i f'JG��i`� 7 ,••.
DATE INSPECTOR
D tE6gUIC
FEB 11 2025 UO
Building Department
Graham Associates 256 Orinco Dr,Brightwaters, ?MjjbT$8uth®id
Building Consultants &Expeditors (631)665-9619 Fax(631)969-0115
February 10, 2025
Town of Southold Building Department
Post Installation Certification
Kochmer Residence— 780 Legion Avenue, Mattituck, NY, 11952
Permit No. 51565
Installation Date: 2/5/2025
Inspection Date: 2/7/2025
To Whom It May Concern,
The roof mounted photovoltaic system at the above referenced residence has
been installed properly in accordance with the approved plans and is
certified by Michael K. Dunn, RA, to be in compliance with the minimum
requirements of the 2020 New York State Residential Building Code; Town
Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and
2020 National Electric Code NFPA 70/2020 National Electric Code
including ASCE7-16.
If you have any further questions, do not hesitate to call.
ED n
(a)
M.-On unn,•RA
FIELD INSPECTION REPORT DATE COMMENTS `
6`3
FOUNDATION (IST) y
------------------------------------
FOUNDATION (2ND)
z
.J o
y
ROUGH FRAMING&
PLUMBING 1
r
INSULATION PER N.Y.
STATE ENERGY CODE
Thy
FINAL
ADDITIONAL COMMENTS
Z
1,
l�
. � N
Q
x
E�
. d
b
y
I
4aF� C�a
TOWN OF SOUTHOLD=BUILDING DEPARTMENT
Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
Telephone(631) 765-1802 Fax(631)765-P502 https://www.southoldtownny.gov
Date Received
APPLICATION FOR BUILDING PERMIT ,
2 't
F6r Office Use Only
, j
5 rj S 1 8 2024
PERMIT N0. Building Inspector. � �•-� '�'' Nw
Applications and forms must be filled out in their entirety.Incomplete ,i.���;;•� �;�,5,;<, :.�!�__' -�
applications will not be accepted. Where the Applicant is not the owner,an 'b `�'
Owner's Authorization form(Page 2)shall be completed. j*
Date: I c�1 a��►y
OWNER(S)OF PROPERTY:
Name: 6a rk'e` ilk SCTM#1000-
Project Address:
Phone#: ?�`a� a , _ J�S Email: kL
Mailing Address: Q
CONTACT PERSON:
Name:
Mailing Address: 2941 Sunrise Hwy, Islip Terrace, NY 11752
Phone#: (631) 647-3402 Email: hppermitting@harvestpower.net
DESIGN PROFESSIONAL INFORMATION:
Name: Michael Dunn, R.A.
Mailing Address: 256 Orinoco Dr, Brihtwaters, NY 11718
Phone#: (631) 665-9619 Email: Bayblueprint@aol.com
CONTRACTOR INFORMATION:
Name: Harvest Power LLC
Mailing Address: 2941 Sunrise Hwy, Islip Terrace, NY 11752
Phone#: .(631) 647-3402 Email: hppermitting@harvestpower.net
DESCRIPTION OF PROPOSED CONSTRUCTION
❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project:
❑Other
Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? Dyes ;KNO
1
PROPERTY INFORMATION
Existing use of property: Residence Intended use of property: (no change)
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
this property? Dyes ®No IF YES, PROVIDE A COPY.
® Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by
Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are
punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law.
Application Submitted By(print name): V cAe,\(3 'Authorized Agent ❑Owner
Signature of Applican • Date: 1 `1�p1��•�
STATE OF NEW YORK)
SS:
COUNTY OF SWQAY_- )
KQj:�6 CJ\��d1��c � being duly sworn,deposes and says that(s)he is the applicant
(Name of individual Wing contract)above named,
(S)he is the l
ontractor,Agent, Corporate Officer,etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief;and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this `,�
d 1f�'!J�ay of rJge ,( ,201j
Nnl=Pub OINA LANZA
NOTARY PUBLIC,STATE OF NEW YORK
Registration Ne.01LA6034714
in PROPERTY_OWNERAUTHORIZATI N, CommOssioled ir nEx Suffolk
0a�p
he he app scan E no a owner) _ _ _
11. 60 b kel\ 4tCT \er residingat ��5� Ll��;��� 'eC e,
C do hereby authorize '�"1�,(•�� ) LLC- to apply on
my behalf 7Toklouthold Building Department for approval as described herein.
Owner's fignature Date
Print Owner's Name
2
i
i
Builtlin Department Armlication
j
AUTHORIZATION
{ (Where the Applicant is not the Owner)
i
�.iding at
(Print property owner's name) (Mailing Addresti l-
doherebyauthorize d '1�{`C\e—A
(Agent)
Harvest Power LLC to apply on my behalf to the.
Southold Building Departmenh
(Owner's Signaftf (bate)
-Gat";e r
(Print Owner's.Name)
r
CONSENT TO INSPECTION
4 c
the undersigned,do(es)hereby state:
Owner(s)Name(s)
That the undersigns (is)(are)the owner(s)of the premises in the Town of
Southold,located at c c\ -pmea, ,
which is sho n and designated on the Suffolk County Tax Map as District 1000,
j Section , Block c ,Lot _.
That the undersigned(has)(have)filed,or cause to be filed,an application in the
Southold Town Building Inspectors Office for the following: \h(AWVaKbY\ 0+'—
C1 o 14W s 6n v Qvf SMWrn UAJ-�Jn 11) i-c�jU0&&
n
That the undersigned do(es)hereby give consent to the Building Inspectors of the
Town of Southold to enter upon the above described property, including any and all
buildings located thereon,to conduct such inspections as they may deem necessary with
respect to the aforesaid application,including inspections to determine that said premises
i
comply with all of the laws,ordinances,rules and regulations of the Town of Southold.
The undersigned, in consenting to such inspections;do(es)so with the knowledge
and understanding that any information obtained in the conduct of such inspections may
be used in subsequent prosecutions for violations of the laws,ordinances,rules or
a
regulations of the Town of Southold_
Dated:
'C� gnatu
'110(Print Nam
00, V-,�
ign ature)
(Print Name)
�o��gufFO�,��oG BUILDING DEPARTMENT- Electrical Inspector
TOWN OF SOUTHOLD
c Town Hall Annex- 54375 Main Road - PO Box 1179
o Southold, New York 11971-0959
V4'4 Telephone (631) 765-1802 - FAX (631) 765-9502
V lamesh _southoldtownny.gov,- seanda-southoldtownny.gov
APPLICATION .FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All Information Required) Date: 11/12/2024
Company Name: Harvest Power LLC
Electrician's Name: Carlo Lanza
License No.: ME-68518 Elec. email:hppermitting@harvestpower.net
Elec. Phone No: (631) 647-3402 01 request an email copy of Certificate of Compliance
Elec. Address.: 2941 Sunrise Highway, Islip Terrace, NY 11752
JOB SITE INFORMATION (All Information Required)
Name: Gabriel Kochmer
Address: 780 Legion Avenue, Mattituck, NY 11952
Cross Street: Pacific Street
Phone No.: (312) 218-5599
Bldg.Permit#: 515105 email:gkochmer@gmail.com
Tax Map District: 1000 Section: 142 Block: 2 Lot: 13.1
BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
Installation of a 4.60 kW solar PV system with (10) REC460AA roof-mounted panels.
Square Footage:
Circle All That Apply:
Is job ready for inspection?: ❑ YES ❑✓ NO -]Rough In Final
Do you need a Temp Certificate?: ❑� YES ❑ NO Issued On
Temp Information: (All information required)
Service Size❑1 Ph❑3 Ph Size: 200 A #Meters 1 Old Meter#
❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect[-]Underground❑✓Overhead
# Underground Laterals 1 2 H Frame Pole Work done on Service? Y N
Additional Information:
PAYMENT DUE WITH APPLICATION
�Q
APPROVED AS NOTED
COMPLY WITH ALL CODES OF DATE: '�la- 5 B.P.# l0
NEW YORK STATE&TOWN CODES
AS REQUIRED AND CONDITIONS OF FE 2DO,OD- BY:
SOUNLD TOWN ZBA NOTIFY BUILDING DEPARTMENT AT
SOUMOLDTOWN PLANNING BOARD 631-765-1802 8AM TO 4PM FOR THE
OLDTOWN_TRUSTB FOLLOWING INSPECTIONS:
N.Y.S.DEC FOUNDATION -TWO REQUIRED
$09HOLDHPC FOR POURED CONCRETE
SCHD ROUGH-FRAMING&PLUMBING
INSULATION
FINAL-CONSTRUCTION MUST
BE COMPLETE FOR C.O.
ALL CONSTRUCTION SHALL MEET THE
REQUIREMENTS OF THE CODES OF NEW
YORK STATE. NOT RESPONSIBLE FOR
DESIGN OR CONSTRUCTION ERRORS
Additional
Certification
May Be Required.
ELECTRICAL
INSPECTION REQUIRED
� `aF
Graham Associates 256 Orinoco Drive, Suite A Brightwaters,NY 11718
Planning& Design (631)665-9619
November 12, 2024
Town of Southold
Building Department
54375 Rt. 25
Southold, NY 11971
Re: Gabriel Kochmer Residence
780 Legion Ave
Mattituck, NY
Proposed 4.60 kWDC, 3.80 kWAC PV System
To Whom It May Concern,
Please be advised that I have analyzed the existing roof structure at the
above-mentioned premises and have determined that it is adequate to
support the additional load of the solar panels and a 140 mph wind load and
20 psf snow load without overstress, in accordance with the following:
The 2020 New York State Uniform Fire Prevention and Residential Building
Code; Town of Southold Local Code, Long Island Unified Solar Permit
Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020
National Electric Code including ASCE7-16
G any further questions, do not hesitate to call.
Cn o , Z rn
0�P� `o r
s817
�E w Y O�
Mic ael K Dunn, RA
Y �
PHOTOVOLTAIC ROOF MOUNT SYE rEM
10 MODULES-ROOF MOUNTED - 4.60 kWDC, 3.80 kWAC
780 LEGION AVE, MATTITUCK, NY 11952, USA HARVESTPOWER
HARVEST POWER LLC
41 SUNRISE HIGHWAY ISLIP
SYSTEM SUMMARY: GOVERNING CODES:
SHEET INDEX �EGI )' ERRACE,NY 11752
/Q :(801)969-3585
(N) 10-REC SOLAR REC460AA PURE-RX(460W)MODULES 2017 NATIONAL ELECTRICAL CODE PV-0 COVER SHEET SIC + ' harvest owernet
(N) 10-ENPHASE ENERGY IQ8X-80-M-US MICRO-INVERTERS 2020 NEW YORK STATE UNIFORM CODE PV-1 SITE PLAN WITH ROOF PLAN C9 -y
(N)JUNCTION BOX 2020 NEW YORK STATE RESIDENTIAL CODE PV-2 ATTACHMENT DETAILS �y
(E)200A MAIN SERVICE PANEL WITH (E)200A MAIN BREAKER PV-3 THREE LINE DIAGRAM --I
(N)60A FUSED AC DISCONNECT c
PV-4 PLACARDS&WARNING LABE ffi ►� C
(N)ENPHASE IQ COMBINER BOX
PV-5 ADDITIONAL NOTES
O
PV-6+ SPEC SHEETS _(�
DESIGN CRITERIA: �)'OR.-
ROOF TYPE:-ASPHALT SHINGLE VERSION
NUMBER OF LAYERS:-2 DESCRIPTION DATE REV.
ROOF CONDITION: GOOD
BLDG.PERMIT 11n2/2024 a
ROOF FRAME:-2"X6"RAFTERS @16"O.C.
STORY:-TWO STORY
SNOW LOAD:-25 PSF
WIND SPEED:-130 MPH
WIND EXPOSURE:-C
GENERAL NOTES: -
1. INSTALLATION IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. ARRAY LOCATIONS
2. ENGINEER TO INSPECT PROJECT AFTER INSTALLATION
AND CERTIFY COMPLIANCE.
3. PROJECT TO BE INSTALLED WITH CODE COMPLIANT ;
RACKING INSTRUCTIONS FOR UNI-RAC SOLAR MOUNT PROJECT NAME
SYSTEM. -
4. FOLLOW BALLASTING SCHEDULE ON ROOF PLAN. '1
5. HARVEST POWER, LLC.,THE SOLAR INSTALLATION PROJECT SITE _ C
CONTRACTOR, COMPLIES WITH ALL LICENSING&ALL
RELATED REQUIREMENTS OF THE GOVERNING "d =>_a W
MUNICIPALITIES AND THE LOCAL ELECTRIC UTILITY W U7 O J H
AHJ'S. f f f= Q pp (D
6. THIS PROJECT WILL COMPLY WITH THE CURRENT NEC A ! r N cW O
REQUIREMENTS INCLUDING ARTICLE 690 SOLAR { P r O Z } p
PHOTOVOLTAIC PV SYSTEMS. + =" Y Z O LL
- - Leg {A -. - N ?-
7. THE ROOF WILL HAVE NO MORE THAN A SINGLE LAYER O O V@;yam Y d
OF ROOF COVERING IN ADDITION TO THE SOLAR "Y —7� ` Y'1195 W W r _ Z
EQUIPMENT. IVIItlICIC,�N_. 1.�..,,..-2, '" J U O _I
8. INSTALLATION WILL BE FLUSH-MOUNTED, PARALLEL U11���15@.SI m 00 p
TO AND NO MORE THAN 6.5"ABOVE ROOF ~ H
9. MAINTAIN A MINIMUM OF 18"CLEARANCE AT RIDGE LongFlland J = J
AND AT ONE GABLE EAVE. -s Ha p a
I " .• ' i Q Z
10. THIS DESIGN COMPLIES WITH 130 MPH WIND ;_, f -, -•.y ,�ayS'nQ
REQUIREMENTS OF THE RESIDENTIAL CODE OF N.Y.S " ( Q
AND ASCE 7-16. ;� �. .t (` 27 '
11. WHEREVER THE ROOF PLAN DOES NOT COMPLY WITH a Y " SHEET NAME
rT
ACCESS AND VENTILATION REQUIREMENTS OF THE Shirte y ti
UNIFORM CODE, HARVEST POWER PROPOSES THAT - `7 (;OVER SHEET
ALTERNATIVE VENTILATION METHODS WILL BE -° .}
EMPLOYED. REVIEW AND APPROVAL SHALL BE AT THE SHEET slzE
DISCRETION OF THE MUNICIPALITY IN WHICH THIS �+ "-
DOCUMENT HAS BEEN FILED. L ANSI B
12. THE DESIGN PLANS COMPLY WITH THE 2020 NEW 1 1" X 1 7"
YORK STATE UNIFORM FIRE PREVENTION AND
RESIDENTIAL BUILDING CODE. 1 AERIAL PHOTO 2 VICINITY MAP
SHEET NUMBER
PV-0 SCALE:NTS PV-0 SCALE:NTS �r PV—Q
d �
MODULE TYPE, DIMENSIONS & WEIGHT
NUMBER OF MODULES= 10 MODULES
MODULE TYPE=REC SOLAR REC460AA PURE-RX(460W)MODULES A,Q
MODULE WEIGHT=50.04 LBS/22.7 KG. ����'�
MODULE DIMENSIONS= 68.03"X 47.44"=22.41 SF l /' �`�'Q (10) ENPHASE ENERGY
UNIT WEIGHT OF ARRAY=2.23 PSF Q- ��-
oQ� � ♦%�2F IQ8X-80-M7-US MICRO-INVERTERS HARK ES EST oP�i�l�l�WER LLC
2941 SUNRISE HIGHWAY ISLIP
�� ♦ { ):REC460AA PURE-RX (460W) TERRACE,NY 11752
-3585
` RAFTERS=2"X6"@16"O.0 L:(e01)989tpowernet
PJ 227°AZIMUTH, 13°TILT Harvest ow
♦♦ �-ROOF-##3
-(02)-REC460AA PURE-RX(460W) co �4�
�O , ,' `� RAFTERS=2"X6"@16"O.0 y o 0
r�4bc / 7�, ♦ 227°AZIMUTH, 30°TILT
/' O,Q-fib, ��� ♦ m o 7
(E) GATE(TYP.) �F 'LC \ 0.(� op87 'Y
/ 10
F y IU
vo Sl D,E CS�f� N DATE REV.
� '��,\ s✓ ,\ ♦ ♦ r p ` •�i9, BLD .PERMIT 11/12/2024 0
ol
C ( // 1 ^r,�.�. ♦ _ �♦ ROOF=#2
1 _-
�,�)�%� �}-� iP° , ♦ ♦ _ [(03)jREC460AA PURE-RX(460W)
�j '� ♦ RAFTERS=2"X6"@16"O.0
Ll ♦ 227°AZIMUTH, 11°TILT
r
` �� /'� �_ .. �. .\ I S♦ PROJECT NAME
Qr
o
\ L.. , ; l
�/ �/ `li ♦� ��`` J U ¢ N W 0
(E)200A MAIN SERVICE PANEL I ; ` - ��� ' �7 0 Z 00 a w
WITH (E)200A MAIN BREAKER `� q�O fr �♦ \ter'; -,�/- �� 1 �/ , LL
}: 0
(INSIDE) 0LLJ
(E) UTILITY METER --_ �j ♦` I ;-r'" GARAGE p W J V 0 ~ Z
( i.... ,� O
(E)
(N)60A FUSED AC DISCONNECT �T (' 1 / m � ~ 0
�)
(N) ENPHASE IQ COMBINER BOX 9 ♦` �? �/
E) FENCE _( � Q
/ Q
N 1"PVC CONDUIT �
O -
RUN 7/8"ABOVE ROOF --- i
' ` `♦ (_ "�� �� _' " // SHEET NAME
r
SITE PLAN WITH
ROOF PLAN
�♦` �- J ' ,' (E)TREE(TYP.) SHEET SIZE
( 1"PVC CONDUIT ;�)/ ANSI B
RUN 7/8"ABOVE ROOF �� �L,( _,-' /'v��� ROOF ACCESS AREA: 1 1" X 1 7"
SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND
SITE PLAN WITH ROOF PLAN ���� e-oe� WINDOWSOVER OPENINGS SUCH AS THED LOCATED POINTS OF SHEET NUMBER
BUILDING CONSTRUCTION NLOCAT LOCATIONS WHERE ACCESS POINT DOES
1 SCALE: 1/16"=1' 0" CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS. PV 1
i I
a
h
PV MODULES
HAWESTPO ER
HARVEST POWER LLC
2941 SUNRISE HIGHWAY ISLIP
TERRACE,NY 11752
"801)989-3585
SEE ENLARGED VIEW R GCISb�+. �harvest�ower.net
5 @ H,q� O
kX RP� co7- CIO
(E) ASPHALT SHINGLE ROOF �>2`X6� �y `1�,e in
rn
�7' 4
GENERAL NOTES: ION
1. RAILS TO BE INSTALLED TWO PER PANELS AS SHOWN IN DETA r. DATE REV.
2. ALL PENETRATIONS TO BE MADE@ 48"O.C. BLDG.PERMIT 11/12/2024 0
3. BOLTS TOBE INSTALLED INTO RAFTERS.
4. MINIMUM 2.5"PENETRATION INTO WOOD FOR CODE COMPLIANCE.
NOTE:-
1
ATTACHMENT DETAIL "ACTUAL ROOF CONDITIONS AND RAFTERS(OR SEAM)LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S)INSTALLATION GUIDELINES
SCALE: NTS AND ENGINEERED SPANS FOR ATTACHMENTS."
END/ MID CLAMP PV MODULES
PROJECT NAME
CO _ _
U) O
W
M ()
LLI Lo O _1 I
U < 5(D
L-FOOT O z o � U)
Y Z O �- LL
(E)ASPHALT SHINGLE ROOF W J U dam' Z
0 0
(N) UNIRAC ROOF/ DECK MEMBRANE
3:D O � O J
SM STANDARD RAIL co cc) Z) O
(E) 2"X6" RAFTERS @ 16" O.0
2.5" MIN.
EMBEDMENT SHEET NAME
ATTACHMENT
FLASH KIT PRO FLASHING DETAIL
SHEET SIZE
ANSI B
BUILDING STRUCTURE
5/16" STAINLESS STEEL LAG BOLT 11" X 17"
WITH SS EPDM BONDED WASHER,
ATTACHMENT DETAIL (ENLARGE VIEW) 2-1/2" MIN. EMBEDMENT. SHEET NUMBER
2 SCALE:NTS PV-2
e f
(10) REC SOLAR REC460AA PURE-RX(460W) MODULES BILL OF MATERIALS
(10) ENPHASE ENERGY IQ8X-80-M-US MICRO-INVERTERS EQUIPMENT QTY DESCRIPTION «_
(01) BRANCH OF 10 MODULES CONNECTED IN PARALLEL PER BRANCH SOLAR PV MODULE 10 REC SOLAR REC460AA PURE-RX(460W)MODULES f1p
{
INVERTER 10 ENPHASE ENERGY IQ8X-80-M-US MICRO-INVERTERS
COMBINER BOX 1 ENPHASE IQ COMBINER BOX
SYSTEM SIZE:- 10 x 460W=4.60 kWDC
JUNCTION BOX 1 600V,55A MAX,4 INPUTS,MOUNTED ON ROOF FOR WIRE&CONDUIT TRANSITION HA AVEST� �
HARVEST POWER LLC
10 x 380VA= 3.80 kWAC AC DISCONNECT 1 AC DISCONNECT 60A FUSED,WITH 20A/2P FUSES,240V NEMA 3R,UL LISTED 2941 SUNRISE HIGHWAY ISLIP
TERRACE,NY 11752
REC;I T� TEL:(801)989-3585
www.han2s ower.nef
MICI q
i n
o 'a ��
TO UTILITY GRID :
�f Y� VERSION
L1 L2 N
CRIPTION DATE REV.
BLDG.PERMIT 11/12/2024 0
BI-DIRECTIONAL
M UTILITY METER
SUPPLY TAP WITH 1-PHASE,3-W,
JUNCTION TAP BOX 120V/240V
10 MICRO-INVERTERS IN BRANCH CIRCUIT#1 (N)ENPHASE
I COMBINER BOX (N)12X12X6
t
-I JUNCTION
I ,
a TAP BOX
ti ti I ti 15A (N)AC DISCONNECT 60A
_--_-_-- J -------_ ) FUSED,VISIBLE LOCKABLE PROJECT NAME
(N)JUNCTION BOX LABELED,20A FUSES,
i 240 VAC
20A < 0 ❑
(10)ENPHASE ENERGY i L1 L1 w j M O
20A FUSES 200A =
IQ8X-80-M-US I L 2 L1 L1 N _
MICRO-INVERTERS ; 6 (E)200A MAIN LV Lo O J f--
i
TERMINATOR CAPON LAST CABLE L2 L2 o SERVICE PANEL = Q 00 (� ❑
i W/(E)200A N W Q
CONNECTOR Q-CABLE(TYP) i M" GATEWAY N N o MAIN BREAKER O Z O U) (n
r--------- --- ------ G ------ -- --------------I o (TOP FED) �' O
i I Y O Z O LL
AG N O
L---- --- -C .-- ------- - -- N N �J w Y It �L
I 1 LLJ T r Z
L-------------------i 1 Li � U
EGD ❑ O
O J
(3)#6 BLK RED THHN (2)#4 BLK RED THHN L------------ Ii coI- O F'- Q
(1)Q-CABLE (2)10 AWG THWN-2 (1)#6 THHN STRANDED (1)#6 WHT THHN
(1)#6 BARE CU GND (1)#6 THHN STRANDED GREEN GROUND IN 1"PVC = ~ _
(1)#6 THHN STRANDED GROUNDING Q Z
GREEN GROUND
CONDUIT RUN GREEN GROUND IN 1"PVC
IN 1"PVC CONDUIT CONDUIT RUN ELECTRODE SYSTEM Q Q
SHEET NAME
THREE LINE DIAGRAM
SHEET SIZE
ANSI B
11" X 17"
1 THREE LINE DIAGRAM SHEET NUMBER
SCALE: NTS PV_3
4" y
-I Y
WOMANARNII�G
ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM SOLAR PV SYSTEM EQUIPPED `
COMBINER PANEL WITH RAPID SHUTDOWN
TERMINALS ON LINE AND LOAD DO NOT ADD LOADS HARVESTPOWER
SIDES MAY BE ENERGIZED IN ARVEST POWER LLC
THE OPEN POSITION LABEL LOCATION: AEG I 3 Ag UNRISE HIGHWAY ISLIP
PHOTOVOLTAIC AC COMBINER(IF �'' RACE,NY 11752
MICj 15 . 801)989-3585
APPLICABLE). K it n .harvest owernet
LABEL LOCATION: Co
INVERTER(S),AC DISCONNECT(S),AC TURN RAPID SHUTDOWN
COMBINER PANEL(IF APPLICABLE). �y f
SWITCH TO THE"OFF" SOLAR ELECTRIC
PV PANELS f
POSITION TO SHUT DOWN
PV SYSTEM AND REDUCE ® `o61
�� f
SHOCK HAZARD IN THE ,v 7�
ARRAY. �L Y
RAPID SHUTDOWN
VERSION
� . � . ■
DESCRIPTION DATE REV.
SYSTEM LABEL LOCATION: BLDG.PERMIT 11/12/2024 0
ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE
LABEL LOCATION: DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
UTILITY SERVICE ENTRANCE/METER,INVERTER/DC ARE CONNECTED.
DISCONNECT IF REQUIRED BY LOCAL AHJ,OR
OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ.
�WARNIMG
POWER SOURCE OUTPUT CONNECTION
DO NOT RELOCATE THIS
PROJECT NAME
OVERCURRENT DEVICE
T Q
LABEL LOCATION:
ADJACENT TO PV BREAKER AND ESS
OCPD(IF APPLICABLE). W
BUILDING SUPPLIED BY UTILITY N � _
GRID AND PHOTOVOLTAIC = < o J
SYSTEM p z o U) oC/)
O O a
■ ■ • • • , (N)PV MODULES Z O LI-
WANING: HTVLTIC ! J C� Y � j: Z
W �--
■ ■ SOURCE W -j U o o � J
LABEL LOCATION: Do Ill ~
INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, o Q ~ ~
AT EACH TURN,ABOVE AND BELOW PENETRATIONS, I j C�
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. 2 Q _
O Q Q
D
G
m
PHOTOVOLTAIC AC DISCONNECT SHEET NAME
OPERATING CURRENT: ,� VAC (N)COMBINER BOX PLACARD &
VOLTAGE: (N)ACDISCONNECT WARNING LABELS
NOMINAL OPERATING AC
(E)UTILITY METER SHEET SIZE
LABEL LOCATION:
AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF ( MAIN SERVICE PANEL ANSI B
INTERCONNECTION. (INSIDE) 1111 X 17"
LABEL LOCATION: SHEET NUMBER
POINT OF INTERCONNECTION
(PER CODE:NEC690.56(B),NEC705.10,225.37,230.2(E)) PV-4
1. EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER
MANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULES, EQUIPMENT, AND
METALLIC COMPONENTS ARE TO BE BONDED. IF THE EXISTING GROUNDING HARVESTPOWER
ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, HARVESTPOWERLLC
G I S T 1 SUNRISE HIGHWAY ISLIP
IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL Fz� �� RRACE.NY11752
GROUNDING ELECTRODE. 'q . :(801)989-3565
e vw.harvestoowernet
2. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL
ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC, ENGRAVED OR m
MACHINE PRINTED IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL O Lo�s
BE UV RESISTANT IF EXPOSED TO SUNLIGHT. �
3. AC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED, "CAUTION AC VERSION
DESCRCIRCUIT" OR EQUIV. EVERY 5 FT. LDG.P RMITTION DATE REV.
BLDG.PERMIT 11/12/2024 0
4. EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT
SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A).
5. CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO
CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER
VOLTAGE OPERATIONAL RANGE.
6. OUTDOOR EQUIPMENT SHALL BE NEMA-3R RATED OR BETTER.
PROJECT NAME
7. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND
ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. � o
Lu M O
8. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL = Lu> rn oo
MEANS DESIGNED AND LISTED FOR SUCH USE, AND FOR ROOF-MOUNTED U Q N w O
SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELP OFF OF THE p z o co
ROOF SURFACE. NEC 110.2 - 110.4 / 300.4 — Z o a O
W W Y � ~ z
9. ALL ROOF PENETRATIONS MUST BE FLASHED. SIMPLY CAULKING DOES NOT o Z) oo -�
SUFFICE. 00 0o �- o ~ O
Q r-
U' Q z
� Q Q
SHEET NAME
ADDITIONAL NOTES
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
PV-5
REC ALPHA PURE-RX 5ERIE5 ®`` REC
SOLAR'S MOST TRUSTED PRODUCT SPECIFICATIDN5HARVEST€ OWER
HARVEST POWER LLC
2941 SUNRISE HIGHWAY ISLIP
NNNAILDATA �G I s T TERRACE,NY 11752
! TEL:(801)989-3585
£ 88 half-cut REC bifacial heterojunctton cells +
1 Cell type: M stICM e iteWww.harve ower.net
Y,• d with l wea-free gapess technology
y l thl /
(i 32 mm sotarglasswith anti-reflective surface treatment
aco
Glass: inamordanmwith EN12150
��" ,� .�I •Backsheet: Highly resistant polymer
� Frame: Anodized aluminum(black)
C
4-part,4bypassdiades,lead-free` j ib
Junction box. t9 i i
IP68 rated;in accardancewith IEC62790
y
I
i
REC ALPHA
StaubliMC4PV-KBT4/KST4(4mmz)
Connectors:
in accordancewithlEC52852,IP68onlywhencannected t= - Cable: _ 4mmxsolarcable,1.7+1.7m, ,as! t
PURE-RX I h inac05x3Oda mm,EN5061) - -
3 Dimensions: 1728x1205x30mm(2.OBm) -•� � � VERSION
__ -... .. swza DESCRIPTION DATE REV.
P Weight 23Akg
1 A W SPECIFICP�TIO Origin: Made in5ingapore fM BLDG.PERMIT 11/12/2024 0
Measurements in mm
ELECTRIGALDATA ProductCode:RECxxxAARure-RX' _ CERTIFICATIONS
Power Output P.(Wp) 450 460 470 IEC612152 173 021,IEC6 0:2016 UL61730
i - - IEC62804 PID
!! Watt Class Sorting-(W) 0/+10 0/+10 0/+10
IEC61701 SaI ist
NorhinalPowerVoltage-V.,(V) 54.3 54.9 55.4_ IEC62716 Ammonia Resistance
Nominal Power Current-I.,(A) 8.29 8.38 8.49 ISO11925-2 Ignitability(EN 13501-1 Class E)
.; to Open Circuit Voltage-Voc(V) 65.1 65.3 65.6 JEC62782 Dynamic MechanicalLoad
- - IEC61215-2:2016_ Hailstone(35mm)
Short Circuit Current-Isc(A) 8.81 8.88 8.95 IEC62321 Lead-fre.eacctoRoHSEU663/2DIS
PowerDensity(W/m2) 216 221 226 IEC617302:2016_ Fire Class C(as per UL_790)
Panel Efficiency(%) 21.6 22.1 22.6 15014001,1S09001,IEC45001,IEC62941
. take „ray
C E 0 Power Output-P (Wp) 343 350 358' � PROJECT NAME
Nominal Power Volta ge-V_e(V) 512 51.7 522
NominalPowerCurrent-ly,,�(A) 6.70 6.77 6.86 Declares` 'o c-`�1 Q
■ r Q
Z Open Circuit Voltage_Vo,(V) 613 61.6 61.8 r
Short Circuit Current-Isc(A) 7.11 7.17 7.23 TEMPERATURE RATINGS __ U) O
_ 3 J
Values at standard testconditions(STGa'v massAM 1.5.irradiance 1000 W/m',temperature25°C�based on a production spreadwith a Nominal Module OperatingTemperatUre: 44°C(32`C) CW _ N T O
tolerance ofP',.V.&Iy 13%within onewatt class m Noinal module operatmgtemperature(NMOT:armassAM15,irradiance 800 W/m', Temperature Coefficientof P_: -0.24%/-C C � J
Wlt■ -• -• temperature 2Tr_windspeedl m/s}-Wher-indicatesthe nominalpower class(Pj atSTCabove. _ _ _ O
Temperature coefficient ofVoc: -0.24%/-C 2
CMAXIMUM.RATINGS ... _ WARRANTY - - .-- Temperature coefficient oflsc: 0.04%/-C o r N W 0
Operational temperature. -40_+85-C, Standard RECProTnat - O Z Q U) U)
- Maximum system voltage: 1000V Installedbyao REC No Yes Yes temperature coefficients m .0 O ^
• ■■ -- - - - -- - .. -- . - .. LL
Certified5olarProfes ional E Y ---�� _ Z O L.L
RELIV R I FORMATION
Maxlmumtestload(front): +7000P.a(713kg/ma}': -' -+ n
■ -• - - System Size All c25 kW 25-500 kW -J �-/ 0
- M aximum test load rear: -4000Pa 407k m2' - Panelsperpallet: 33 w Y
(rear): ( 8/ ) ProductWamanty(yrs) 20 25 25 c I--
-- Panels per40ftGP/highcubecontainer. 594(l8pailets)
t Max series fuse rating: 25A Power Warranty(yrs) 25 25 25 .....- ._-.. .. _- -..__ ..__ ._ _ _..._ _ J 0 Q ,..I
Max reverse current 25A Labor Warranty(yrs) 0 25 10 Panels per 13.6 m truck: 660(20palletsj r^ M Q
_ 'Seeinstallation manual rormountin instructions Powenn Yearl 98% 98% 98% W 05 0 � 0
y o e g LQW LIGHT BEHAVIOUR cp (�
Design load-Testload/15(safety factor) Annual Degradation 025% 0.25% 025%
- Typical low Vradiance performance ofmoduleatSTC: un rn Z
it Power of Year 25 92% 92% 92% o V
'■`"` / *' a. • - The RECProTrustwarranty isonlyyavailable an panels purchased sI a Q
� .-,■ throughanRECCertified5olarProfessional installer.Warranty C
•W;y>� _ - / conci donsapply.Seewww.recgroup.mmformoredetails. .. _ .- ¢ G Q
--------------
a
Available from: a alrradtanm(W/rrR)` -
SHEET NAME
SPEC SHEET
SHEET SIZE
Founded in is anintemational toneerin solarener company dedicated toem owerin consumers RECSoIarPTELTO. ANSI B
P P g gY P Y P g
with clean,affordable solar power.As Solar's MostTrusted,REC is committed to high quality,innovation,and a low 20TuasSouthAve.14 REC n n
'^'... on Sin a oreg 7312 a+e �/
carbon foot rintln the solar materials and solar panels it manufactures.Headquartered in Norway with operational g p 11 /� 17
_ ,►--, .8tw,..-w , '„ ram""` - - • P P qu Y P
post@rec roup.com www.recgrouRcom
• � -��,.-`- - ._�; ,`3.F��� headquarters in Singapore,REC also has regional hubs in North Americd Europe andAsia-Pacific.
SHEET NUMBER
PV-6
1
1 .�
POWER LLC SOLARMOUNT .
TEL=
BETTER DESIGNS ,f
TRUST THE INDUSTRY S BEST DESIGN TOOL CONCEALED UNIVERSAL f II
i . 1 Start the�esiQn process for every protect m our U•0uilder on-line design tool.. ENDCLAMPS
'
IL s a gram way to save time anal money. • a�� ,; ' �.,
BETTER SYSTEMS
_ -
ONE SYSTEM-MANY APPLICATIONS
z
Quickly s�modules flush to the roof on steep pitched roofs,Orient a.large vailiety BLDG.PERMIT �0
of modules in Portrait or Landscapo.Tilt the system up on flat or low slow roofs.o END CAPS INCLUDED ---
Compone� available in mill,clear,and dark,finishes to optimize your design financials
and aesth tics. WITH EVERY ENDCLAMP BETTER RESULTS
RESULTS
MAXIMIZE PROFITABILITY ON EVERY JOB
CONCEALED Trust Unira to help you minimize hotli system and labor costs from the.lfma the Tab is
UNIVERSAL quoted to la time your learns gel offthoroof faster mstalls:Less Waste,More Prafits
CLAMPS z, UNIVERSAL SELF
4 i:UNIRAC BETTER SUPPORT STANDING MIDCLAMPS'
a25 WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM
Professional support for professional installers and designers.You have access — — PROJECTg
our Nchni al support and lmm ng groups.Whatever your support needs,we've got —�
•1 OPTIONAL YEAR ! youcover;'VisitUnirac.com/selarmountformoreinfoimation. r ` �� N t
FRONT TRIM fULkSYSTDI �,P
WAflflAPITY `�I •
U BUILDER ONLINE DESIGN •
1 1 • ' �, TOOL.SAVES.TIME&MONEY Lii
^+... Eli: UL2703 BONDIUG&GROUNDING
L`, Visit design.unfrac.comLLJ •
MECHANICAL LOADING • •
SYSTEM FIRE,CLASSIFICATION "" • -
t •
H' UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT LLJ -
v
0 CD
' "IU1111TIld 11 1IRI V1 A INI IIIr I I ' ' I UNMh CNEa CERTIFIED ENGINEERINQ BANKABLE DESIGN PERMIT
EXPERIENCE QUALITY EXCELLENCE VIARRANTY TOOLS DOCUMENTATION �
�■ 1 11 i 1. 1 �
TECHNICAL SUPPORT CERTIFIED QUALITY PROVIDER BANKABLE WARRANTY
UnuaCsteC1inical support team is dedicated toanswering Uniracisthe only PVmountingvendorwithISO Don't leave your project toclnnce;Ummchasthe
questions�.addressing issues inreal time.Anonline certificatiopsfor9001:2008,14001:2004 and OHSAS- financial strength to back ourproductsandreduceyourrfsk. SHEET NAME
y of g 007,whichmeansviedeliverthehigheststandards Havepeaccofmmdlgmvyingyou are pravidmgproductsof
CHOICE FOR RESIDENTIAL RACKING stampedettersandtechnilcaldatajsheetsgreatly� forrfOt,frmandfunction.Thesecertificationsdemonstiate exceptional quality.SOLARMOUNTiscoveredbya25year SPEC SHEET
THE PROFESSIONALS C simplifies your permitting and project planning process: ourexceflence and commitmentto firstclass business pfactices. limited productwarranty and a 5 yearlimiled finish warranty.
SHEET SIZE
__. --. - --_ __ __ -- _.. - - ,-i-rlul ni-biiw wuniriiwimiWuinuui ihOmiuiiu�unuunnHunur,nimununnmiuun
IiIIIlu11n1ul,nil11n11nVlpNplllnpjl{niQ1,11UpnIu11IIIIIIIIIpllN�inrplllnpllllllulllllulupl uwifnnunmunninmuim�iinuiuininiinnnNmnminiNurlgnuuiinpl llp All II IIU.J_ll. - _ - .. _ - -. - _-.
BEST INSTALLATION EXPERIENCE*CURB APPEAL•COMPLETESOLUTION•UN,IRACSOPPORT ANSI B
ENHANCt YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN
FOR QUESTLONS OR CUSTOM'.ER' SERVICE VISIT UNIRA.C.COM OR. GALL (50:5) 248 27Q2 px � ,,,,,,.Ln FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2102
r6
• Unirac State Letter-NY HARVESTPOWER
•
...rn<.<:o<onon:...«.no..«<.�a. r.nrna«ownov..uc<rTrohn uevrcc Tectonic WO#:12557.24
!'� AARVEST POWER LLCTectonis Tectonic August 12,2024 G I - 9 UNRI HAY
CENY 11v75215LIP
C�Mt1C ( 01)989-3585
August 12, 2024 ■ Metal Roof:Standing Seam Attachments, PM-9000s,and PM Adjust Slotted harvest owernef
■ Tile Roof: Solar hooks, Flashkit Tile Replacement(TR)Uni
y1P/a 1�
Attn: Engineering Services Department The U-Builder Tool should be used under the responsible charge of a registered m s �C =
1411 Broadway Boulevard NE professional engineer required by the authority having jurisdiction. The design tool O
Albuquerque, NM 87102-1545 and Unirac do not evaluate the existing roof structure, or the PV panels themselves. 7
TEL:(505)242-6411 See the construction and installation drawings and manuals for additional
information provided by Unirac. �� O K 4`
RE: ENGINEERING CERTIFICATION LETTER FOR THE UNIRAC SOLARMOUNT (SM)
ROOF PV PANEL SUPPORT SYSTEM Sincerely, of NEW VERSION
STATE:NEW YORK Tectonic 'C� 1'O DESCRIPTION DATE REV.
TECTONIC WORK ORDER#:12557.25 �Po��o A. GUq� '9� BLDG.PERMIT 11/12/2024 0
* z
The Unirac SOLARMOUNT(SM) Photovoltaic Panel Support System is a proprietary r p Cc
framed photovoltaic panel support system that is installed on a roof. Tectonic I U
Engineering Consultants, Geologists & Land Surveyors, D.P.C. (Tectonic) has _&
reviewed the SM design methodology along with the U-Builder tool; a Unirac online °A 071249 %,
design tool. The review included the following SM products, SM Light, Heavy Duty, s10NP 08/12/2024
and Standard rail with both the standard and pro hardware.
Antonio A. Gualtieri, P.E.
Tectonic has determined that the design is a rational approach and follows the Executive Vice President
structural requirements of the following reference documents:
Codes/Standards:
• 2020 Building Code of New York State. PROJECT NAME
• 2018 International Building Code by International Code Council. Q
ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures, by j o
American Society of Civil Engineers with provisions from SEAOC PV-2-2017. J
2020 Aluminum Design Manual, by Aluminum Association. W c� O
LLILo 0 J
This letter certifies that the structural analysis of the racking members,connections, = > 0)
and components directly related to Unirac's system are in compliance with the U Q N W O
above codes. The design methodology is acceptable under components and Z o U) U)
0
cladding loads associated with the building's roof structure when the system is
Z
installed in accordance with manufacturer specifications. If the loading criteria does J ('� CN >_ O
not meet Unirac's specifications, owner shall contact Unirac for a site-specific W Y LLI r- 1— Z
certification. C) 0 --i
0 o —
00 00 E— 0 H O
Attachments approved for the SM system to the structure include the following Q ~
and is installed per Unirac's U-Builder report and installation guides: Q Z
� � 2
■ Shingle Roof: L-Foot Flashkit Pro, Standoffs, Flashloc Comp, Flash Loc Duo, Q Q
and Flash Kit Pro SB
SHEET NAME
Project Contact Info Project Contact Info
SPEC SHEET
1279 Route 300 1 Newburgh,NY 12550 1279 Route 300 1 Newburgh,W 12550
845.567.6656 Tel 1 845.567.8703 Fax 845.567.6656 Tel 1 845.567.8703 Fax
SHEET SIZE
tectonicengineering.com tectonicengineering.com page 2 of 2 ANSI B
Equal Opportunity Employer Equal Opportunity Employer
11" X 17"
SHEET NUMBER
PV-8
PHOTOVOLTAIC ROOF MOUNT SYSTEM
10 MODULES-ROOF MOUNTED - 4.60 kWDC, 3.80 kWAC H,
780 LEGION AVE, MATTITUCK, NY 11952, USA HA HA AVEST,'
RVEST POWER LLC
2&11 S 1 ISUP
SYSTEM SUMMARY: GOVERNING CODES: SHEET INDEX
(N)10-REC SOLAR REC460AA PURE-RX(460W)MODULES 2017 NATIONAL ELECTRICAL CODE PV-0 COVER SHEET v \
(N)10-ENPHASE ENERGY IQBX-BD-M-US MICRO-INVERTERS 2021 NEW YORK STATE UNIFORM CODE PV-1 SITE PLAN WITH ROOF PLAN
(N)JUNCTION BOX '({Wjp_l 20 NEW YORK STATE RESIDENTIAL CODE PV-2 ATTACHMENT DETAILS �
(E)20DA MAIN SERVICE PANEL WITH(E)200A MAIN BR PV-3 THREE LINE DIAGRAM
(N)ENPHASE IQ COMBINER BOX PV-4 PLACARDS&WARNING LABELS
PV-5 ADDITIONAL NOTES
('
PV-6+ SPEC SHEETS p 11 O��
DESIGN CRITERIA: MAR -� 5 2025U0 OF t4
��y
ROOF TYPE:-ASPHALT SHINGLE v
NUMBER OF LAYERS:-2 DESCRIPTION DATE REV.
ROOF CONDITION:GOOD
BLDGFEfiNIT 11/1]lt024 D
ROOF FRAME:-2"X6"RAFTERS @16"O.C,STORY:-TWO STORY Building Department
SNOW LOAD:-25 PSF WIND SPEED:-130 MPH TOM Of
Southold
WIND EXPOSURE:-C
GENERAL NOTES: ---�z -.. - --- -- - -- --------—---'—--------
1. INSTALLATION IN ACCORDANCE WITH MANUFACTURER q
RECOMMENDATIONS. • FARRAY LOCATIONS
2. ENGINEER TO INSPECT PROJECT AFTER INSTALLATION ♦�.
AND CERTIFY COMPLIANCE. -
3. PROJECT TO BE INSTALLED WITH CODE COMPLIANT /:
RACKING INSTRUCTIONS FOR UNI-RAC SOLAR MOUNT I PROJECT NAME
SYSTEM. I Q r
4. FOLLOW BALLASTING SCHEDULE ON ROOF PLAN. -F '�+ , O
5. HARVEST POWER,LLC.,THE SOLAR INSTALLATION +�. PROJECT SITE I < O� '--I
CONTRACTOR,COMPLIES WITH ALL LICENSING&ALL ,. ------�--'--- LL1 C) O
RELATED REQUIREMENTS OF THE GOVERNING
MUNICIPALITIES AND THE LOCAL ELECTRIC UTILITY - LU Lr)
AHJ'S. i I O Z � N w O
6. THIS PROJECT WILL COMPLY WITH THE CURRENT NEC
REQUIREMENTS INCLUDING ARTICLE 690 SOLAR I - Z > O
PHOTOVOLTAIC PV SYSTEMS. '"- Y z N EL LL.
Q
7. THE ROOF WILL HAVE NO MORE THAN A SINGLE LAYER : 780 Legldh', ve;, --1 .�
OF ROOF COVERING IN ADDITION TO THE SOLAR _ - _ Ma%tLkk':'NV"11952; LLI J U o Z
EQUIPMENT. - '
8. INSTALLATION WILL BE FLUSH-MOUNTED,PARALLEL . - - _ Urilted_"StateS_ CO 00 F O ? p�
TO AND NO MORE THAN 6.5"ABOVE ROOF I -
9. MAINTAIN A MINIMUM OF 18"CLEARANCE AT RIDGE �`• Lmlyvslani7 _.
j ~
AND AT ONE GABLE SAVE. - _-- Hampton; z Q =
10. THIS DESIGN COMPLIES WITH 130 MPH WIND Bays Q Q
REQUIREMENTS OF THE RESIDENTIAL CODE OF N.Y.S _
AND ASCE7-16. .� -• z5"._•=-
11. WHEREVER THE ROOF PLAN DOES NOT COMPLY WITH -ShUley SHEET NAME
ACCESS AND VENTILATION REQUIREMENTS OF THE
UNIFORM CODE,HARVEST POWER PROPOSES THAT .\v, COVER SHEET
ALTERNATIVE VENTILATION METHODS WILL BE
EMPLOYED.REVIEW AND APPROVAL SHALL BE AT THE SHEET SIZE
DISCRETION OF THE MUNICIPALITY IN WHICH THIS
DOCUMENT HAS BEEN FILED. l r,_ _�— _.__ __ ____ �____.___�___ __. ANSI B
12. THE DESIGN PLANS COMPLY WITH THE 2020 NEW
11"X 17"
YORK STATE UNIFORM FIRE PREVENTION AND
RESIDENTIAL BUILDING CODE. 1 AERIAL PHOTO 2 VICINITY MAP
/�/' SHEET NUMBER
PV-O SCALE:NTS PV-0 SCALE:NTS •(�J PV-0
MODULE TYPE,DIMENSIONS&WEIGHT "
NUMBER OF MODULES=10 MODULES _
MODULE TYPE=REC SOLAR REC460AA PURE-RX(460W)MODULES A
MODULE WEIGHT=50.04 LBS 122.7 KG.
MODULE DIMENSIONS=68.03"X 47.44"=22.41 SF �v i `♦F
UNIT WEIGHT OF ARRAY=2.23 PSF �' ' �� (10)ENPHASE ENERGY _
Q4i� \♦(j2 IQBX-60-M-US MICRO-INVERTERS HARVEST: ,",
QQO ♦ HARVEST POWER LLC
ROOF#1 2941 SUNRISE HIGHWAY ISLIP
\♦♦ (05)REC460AA PURE-RX(460W) 11752
RAFTERS--2"X6" 16"O.0 Fi ses 227°AZIMUTH,113°TILT ��
O
♦♦ ROOF#3
(02)REC460AA PURE-RX(460W) 2Z
��O �� i�\ `♦ RAFTERS--2"X6"@16"O.0
G�/ �4�• 1)\� 227°AZIMUTH,30°TILT
(E)GATE(TYP.) �LyG1 ozs611 y0
/ - = +•. �� \;Y
DESCWPTIDN DATE REV.
^/, �\ rr,! �♦ ♦ _, 0
` St9, OLDOPERIM 111=24 D
! ,f ^ v i \' ♦ ♦ ♦� ROOF#2
(03)REC460AA PURE-RX(460W)
i+,, ,, —\ o:' ♦ \ RAFTERS=2"X6"@16"O.0
227°AZIMUTH,11°TILT
f !
PROJECT NAME
( ♦ O J
T
% I M CD
- Lij
J) 0 z o vw) uoi
(E)200A MAIN SERVICE PANEL l- �_; p O O
WITH(E)200A MAIN BREAKER �e I � � \ / ��' J 0 Z N U-
(INSIDE) ♦ iLlr( i ��� —� W_ W V _H
(E)UTILITY METER ----' �� i } ) ; (E)GARAGE lZ' O 7 Ill GO F_ O J
rr
(N)ENPHASE IQ COMBINER BOX Ai9 ) \JIL 1 J ! z
' U' Q z =i
(E)FENCE IL Q
(N)1"PVC CONDUIT /_^— \�l. :j r� �y�ry Q
RUN 7/8"ABOVE ROOF
SHEET NAME
SITE PLAN WITH
ROOF PLAN
�/ ♦` •( ` J � (E)TREE(fYP.) SHEET SIZE
J\I (N)1"PVC CONDUIT - -- ANSI B
1 RUN 718"ABOVE ROOF A'POA ROOF ACCESS AREA 'I'I°X 1 T"
F QL SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND
1 s I TE PLAN WITH ROOF PLAN OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND LOCATED AT STRONG POINTS OF SHEET NUMBER
BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT `/
SCALE:1/16"=1'-0" 2F` CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS. P V-�
PV MODULES a
HARVEST-'?-".
S OWER LLC
.SUP
Q931t� Yz
um
SEE ENLARGED VIEW c @ 16,O G
Q et
yy
(E)ASPHALT SHINGLE ROOF oeo) ,
a
o2sB+l O�
TFOF NE'~y
GENERAL NOTES: VERSION
1. RAILS TO BE INSTALLED TWO PER PANELS AS SHOWN IN DETAIL. DESCRIPTION DATE REV.
2. ALL PENETRATIONS TO BE MADE@ 4F'O.C. luoorstaatr tvtarzoza o
3. BOLTS TOBE INSTALLED INTO RAFTERS.
4. MINIMUM 2.5"PENETRATION INTO WOOD FOR CODE COMPLIANCE.
NOTE:
J)ATTACHMENT DETAIL "ACTUAL ROOF CONDITIONS AND RAFTERS INS(ORTAL SEAM)LOCATIONS MAY
VARY.INSTALL PER MANUFACTURER(S)SCALE:NTS AND ENGINEERED SPANS FOR ATTACHMENTSLATION GUIDELINES
END I MID CLAMP PV MODULES
PROJECT NAME
I
m ❑
W
w in C)
UQ � c, W0
L-FOOT O Z o a) V)
Y O c)
Z u0
(E)ASPHALT SHINGLE ROOF I j Lu Y —If-' Z
o � c:)
(N)UNIRAC ROOF/DECK MEMBRANE m ao H o F- O
SM STANDARD RAIL Q -~ I-
(� ~Q Z 2
(E)2"XV RAFTERS @ 16"O.0
2.5"MIN.
EMBEDMENT m SHEETNAME
I Pi ATTACHMENT
FLASH KIT PRO FLASHING DETAIL
SHEET SIZE
ANSI B
BUILDING STRUCTURE 5/16"STAINLESS STEEL LAG BOLT
11"X 17'
WITH SS EPDM BONDED WASHER,
OATTACHMENT DETAIL (ENLARGE VIEW) 2-1/2"MIN.EMBEDMENT. SHEET NUMBER
SCALE:NTS PV-2
(10)REC SOLAR REC460AA PURE-RX(460W)MODULES BILL OF MATERIALS
(10)ENPHASE ENERGY IQBX-80-M-US MICRO-INVERTERS EQUIPMENT QTY DESCRIPTION
(01)BRANCH OF 10 MODULES CONNECTED IN PARALLEL PER BRANCH SOLAR PV MODULE 10 REC SOLAR REC460AA PURE-Rx(460M MODULES
i
INVERTER 10 ENPHASE ENERGY IQBX-80-M-US MICRO-INVERTERS
COMBINER BOX 1 ENPHASE IQ COMBINER BOX _
SYSTEM SIZE:-10 x 460W=4.60 kWDC JUNCTION BOX 1 600V,55A MAX,4 INPUTS,MOUNTED ON ROOF FOR WIRE 8 CONDUIT TRANSITION HARVEST=
HARVEST POWER LLC
10 x 380VA=3.80 kWAC IGHWAY ISL P
8DR-7555.11752
1
INTERCONNECTION
120%RULE-NEC 705.12(B)(2)(3)(b) �14/ 'G
UTILITY FEED+SOLAR BACKFEED �Z
200A+20A=220A
BUSS RATING x 120% N �~
200A x 120%=240A 02981 0�
FO �y
SION
OESCRIPRON DATE REV.
B RL .PERMIT 11/12/ZO24 0
I-DIRECTIONAL
UTILITY METER
1-PHASE,3-W,
12GV124OV,60HZ
10 MICRO-INVERTERS IN BRANCH CIRCUIT#1 (N)ENPHASE
COMBINER BOX
L +}
(E)2GOA MAIN
SERVICE PANEL
W/(E)200A
MAIN BREAKER
I e� I ti I 15A
1 (TOP FED) PROJECT NAME
---- �------ `-�--� JUNCTION BOX
Q
20A (N)BREAPKERR 200A�( ? O
�ro-L
(10)ENPHASE ENERGY I _ W ch �
IQ8X-80-M-US —_-_ W CN p J F,
MICRO-INVERTERS I _ > 0) p
TERMINATOR CAP ON LAST CABLE I �= V a N W O
0
(LLL
CO -GABLE M• GATE JI I O } O j}W YLL
- D _j �
C}- LLI - F- ZL - G ---- uj V O -1 O O>
m OD F o 0
(1)Q-CABLE (2)10 AWG THWN-2 (2(1) 6WWTBUK RED THHN - --
(1)#6 BARE CUGND (1)05 THHN STRANDED STRANDED
THHN -- z
GREEN GROUND (1)R6 THHN STRANDED GREEN GROUND EXISTING GROUNDING
IN 1'PVC CONDUIT RUN SYSTEM � d Q
IN 1"PVC CONDUIT Q
SHEET NAME
THREE LINE DIAGRAM
SHEET SIZE
ANSI B
11"X 17
THREE LINE DIAGRAM SHEET NUMBER
1 SCALE: NTS PV-3
�y-y T .pa.. g�..,-i 1�r •. �f 4., ---
A1N�,A�R�,N NG , r �WA�RNING '=
ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM SOLAR PV SYSTEM EQUIPPED
COMBINER PANEL WITH RAPID SHUTDOWN HARVESTI-
TERMINALS ON LINE AND LOAD DO NOT ADD LOADS
SIDES MAY BE ENERGIZED IN HARVEST POWER LLC
THE OPEN POSITION LABEL LOCATION: 2941 TUNRISE NIGH117215UP
PHOTOVOLTAIC AC COMBINER(IF
S
APPLICABLE).
LABEL LOCATION:
INVERTER(S),AC DISCONNECT(S),AC 3" TURN RAPID SHUTDOWN ` 'D
COMBINER PANEL �
IF APPLICABLE). G �/
( ) SWITCHTOTHE"OFF" '°w �� Z
POSITION TO SHUT DOWN
PV SYSTEM AND REDUCE
SHOCK HAZARD IN THE .
_,�
ARRAY. �
etT O
• SOLAR
, DESCMI-TIO TE REV.
LABEL LOCATION: DLOO.PERMIT llli=a D
ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE
LABEL LOCATION: DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
UTILITY SERVICE ENTRANCE)METER,INVERTER)DC ARE CONNECTED.
DISCONNECT IF REQUIRED BY LOCAL AHJ,OR
OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ.
W%AR?NINO'
POWERSOURCE OUTPUT CONNECTION
DO NOT RELOCATE THIS PROJECT NAME
OVERCURRENT DEVICE
Q C 0
LABEL LOCATION: U) O J
ADJACENT TO PV BREAKER AND ESS Z) o O
OCPD(IF APPLICABLE). W
BUILDING SUPPLIED BY UTILITY ui� o
GRID AND PHOTOVOLTAIC U Q � N w o
SYSTEM O z o cn
_j0 LL
�
■ . , • . , (N)PV MODULES ® Z N O
W_ WV � HZ
PO � o � -0
ti H
LABEL LOCATION: o In ~ O
Q
INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
AT EACH TURN,ABOVE AND BELOW PENETRATIONS, m Z
ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. O -- - Q
Z Q
G
m
PHOTOVOLTAIC AC DISCONNECT f SHEETNAME
PLACARD&
• •• ;� • - (M COMBINER BOX
NOMINALOPERATING AC VOLTAGE: (E)UTILITYMETER WARNING LABELS
(E)MAIN SERVICE PANEL SHEET SIZE
LABEL LOCATION: (INSIDE)
AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF ANSI B
INTERCONNECTION. 11"X 17"
LABEL LOCATION: SHEE:TNUMBER
POINT OF INTERCONNECTION(PER CODE:NEC690.56(9),NEC705.10,225.37,230.2(E)) PV-4
1. EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER
MANUFACTURER'S REQUIREMENTS.ALL SOLAR MODULES,EQUIPMENT,AND
METALLIC COMPONENTS ARE TO BE BONDED.IF THE EXISTING GROUNDING HARVEST!:`
ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, HARVEST POWER LLC
2941 SUNMSE HIGHWAY ISUP
IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL SUPPLEMENTAL ER Nr11Tsz
GROUNDING ELECTRODE. !
2. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL
ELECTRICAL CODE.LABEL SHALL BE METALLIC OR PLASTIC,ENGRAVED OR
MACHINE PRINTED IN A CONTRASTING COLOR TO THE PLAQUE.PLAQUE SHALL j
BE UV RESISTANT IF EXPOSED TO SUNLIGHT. 0,9 1
l�
3. AC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED,"CAUTION AC r NrvERsfoN
DESCMMON DATE REV.
CIRCUIT"OR EQUIV.EVERY 5 FT. MDG ER 1„22P. o
4. EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT
SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A).
5. CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO
CONNECTING INVERTER.VERIFY SERVICE VOLTAGE IS WITHIN INVERTER
VOLTAGE OPERATIONAL RANGE.
6. OUTDOOR EQUIPMENT SHALL BE NEMA-3R RATED OR BETTER.
PROJECT NAME
7. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ¢ r
ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. W Z) M O
8. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL = o
MEANS DESIGNED AND LISTED FOR SUCH USE,AND FOR ROOF-MOUNTED U ¢ N w O
SYSTEMS,WIRING MUST BE PERMANENTLY AND COMPLETELY HELP OFF OF THE U Z Y0z} o a U) co
oo
ROOF SURFACE. NEC 110.2-110.4/300.4 J 0 N
w w Y r F Z
9. ALL ROOF PENETRATIONS MUST BE FLASHED.SIMPLY CAULKING DOES NOT Jo j o J
SUFFICE. < ti o Z) O
¢ z =
Q ¢
SHEET NAME
ADDITIONAL NOTES
SHEET SIZE
ANSI B
11"X 17"
SHEET NUMBER
PV-5
REE ALPHA
RK
^w7
SOLARS MOST TRUSTED RE HARVESTz.CA,:r i=
HARVEST POWER LLC
-- 2941 SUNRISE HIGHWAY ISLIP
[GENERALDATA_ �� NY 77752
BBl,a(vtRECMfaclalhetem)w Uoncells --a—v— IFj6y ,7 t lnef
1 jam, Sas
Ce01YDr wlthteaifne,gaplesstedngbgy -
Gloss: 32mmsdarglasswitlreMi-reflectirewrfacetreatment I �PEL K0 '�a5
T N.aadavwithENU15 �G GA \0
Badsheet: Hlghlyreslsuntis.1 Par .L
d- Frame: Arudludalunbum@lad)
lu
REC ALPHA® m ndlonbm -p.m N
: 4 -Aleypassdbde;lead-free
Ip-paraardaaaewlNIEC61750 N
`4" Comecturs: Staublt MC4 PV-KBT4/KST4(4-1) �o-u r ✓
Ifl-_ Narr•d•v.101ECfi78521P6eaAya.kmmnnwt.d 0298 0
PURE-RX SERIES .mm°edarcab1e.12.L7m
Cable: murard.ar.ratnpJJsdfile o` �' F 1 I
._-i`•~r Dimensims: 1728a 1205z30rmn(2DBmr1 u OE9CW DATE REV.
Weight, 23.09
PRODUCT SPECIFICATIONS IN Ill Drlglm Mad."Ir spore Mas.r.n.rowNmm
9LDD.PERMR ,1/122D24 0
.
Rrr ELEL7RICALOATA ,__Pmdlut Code rRECnaMPu_RX CERTFlUTIONS ,
' P Output-P,w{Wp) 450 460 470 IEC61215202I,IEC6A30:2016,UL6A30
WaltClass So<tmg-Iw9 D/.10 0/No 0/.10 IEMET PID
IEC61701 5ah Mirt
NaninalP_.'voltev-V,,,M 543 54.9 55.4 IEC.M6 AmmudaResistance
u Nominal Pow.,Cument-I_(A) 829 838 849 15011925-2 IgNtabdity(EN1350HOenEI
. Nw' m Open C6cuity thev-v.m 6S.1 653 65.6 IEC62792 Dynamic MvdmNcdL.M
orlCtmultCurrent- (A) 891 EBB 895 IEC61215-22016 Haflstme(35mm)
Sh
Isc IEC62321 Lea6frreac0oRoHSEUB53/20I3
Prwe'Dwoity(w/mal 216 221 226 IEC6173D-2:2016 Fire CIsw C(espwUL79M
P..IEfAci.ncy(,6) 21.6 22.1 2216 L901400LI5D9M IEC45007,EC62941
_ _ Me
Pow"tput-P—IWp) 343 ME 358 C E
r.er,..as.....
l NvnirW PowerVdtaga-Vwy(Vl 512 517 522 PROJECT NAME
Nwnirwl P°warc_t-I_(A) 6.70 6.77 686 Declare.
OP'ncimdtvoIaAe-Vw(vj 613 61.6 61.6
ShortCI c ItCrarent-IK(A) 7.11 7.17 7.23 'ySEMP82117URE RATINfd' O
Ve6waatsuMadr.stmkaiomlSTC:samasrAMtS.ar.dimnlOooW/m'.tmma am+25'cLlwidmaPa4rnlmsprndrvXha NwntnalModule0paaMgTwpe. e: 44-C(e2T) LU N r T
tdwaac.dP,•,.ve4,3ve..+w,aT.,nrl.awa:wrrn,4/r.pw.t:orwrprr.v..nan7:.ara.wu4ls.r<,aaar.emwArr. T_owa acasfRdene°fp,r, -a24%PC .. LU Ln
COMPACT mrvwau..as[.mrp..el"Wwhrr.mL,dr tnm.aa,;a.l,,,e.m„P�dasrc.6.,e U
_ Temperat�a fiklarldvw: -024%PC 2 Q p (9
MAXIMIlA1RATfNGS_ _ Temperaturecoet6dentofl,�: 004%/•C �a O Z 0 W 0
OperaHnnattsw,swere _ -40.-es'C standard RECPr.Twt -re.w wr.m.m.r.nu.wr.a.r.m.v..a.. tl It `' Z >_ 0 U) O
tl Masaownsystemreltagr. 1000V aetailedMmREC No Yes Yes ^• u Y Z Q LL
\ CanfialSdandeakawl fOaIVERYINf-ONMATIDN. ``tn, N
Ma.Mumlestload(Froni} .7000Per/Bkg/maJ 9ysmm5lze All .25kW 25-SmkW .J V }•
r. •• WITH MLPE Mubrum[estlmtl(reark -4000Pa(4D7kg/mar pr,duawarranty(yn) 20 25 ZS Panelsparpa9ei: 33 W Y Z
Maysarb.fuwratkg 25A Pow.rwamantyt,.) 25 25 25 P°n°lspw40fIGP/htphribemrmhrw: 594Ugpalktsl _ J U O J
Masre.erse current 23A La6orWawanrylyrs) 0 25 ID Panelsyw13.6.ho k: 66olzopauets)
_ _ •swwtaturoaar.audr>rna.,WWqq Pmrerlov.ml 98% 96% 98% (LDWLIGHTSEHAVIIRRt $ m CO ~_ O ? Q
0.sunbad•rertlaN/t5(.ar.ryf d>) A-1 adatloo 025% 025% 025% - - '`' Q
w• UYR
PowerN m25 92% 92% 92% TyplcallawhradWrreperfwm f._oduleet5TC: o /C1ZRu AFCAobaslWurmryS•dr.radab6enpwlsrwrNwd 6 V cc nn r A CryIAy M°wf'pr'mpn`i•etae.+e.r:l: C n G < 4,'t
o
a AyallnNefrone �hoawolw/m'1 SHEET NAME
SPEC SHEET
a_.-. "'-'.-• _ �.f�:.-:•- SHEET SIZE
ANSI B
Foundedb199QRECGrouplsaninterrotmnalptoneedngwlarenergycampanyded¢atM toempowerirgmmtvnen RECSduPTELTD. t^ �]r
-� -_ selarp20Tap..6hAee.14 t RCC 11"X 17P
with wecAz Sdats Most Tmsted•RECkmmNnedtohltatw1t...Inwvatlon.andalovr
_ ��_��r s: carbon I-pdnt Inthe solar matert.1—olwlarpanels it mawfactures.Headquartered In Norway with op,.I.al P.at@,ejT_3II
�. T•- ^._MGM. -,.t • S' Post�recgmupcom vmwrvcgywrpcom
-.- headgoat-1.5mgappre.RECalsoh—eglorelkubstrNorthAmeriyEwope,andAsla-Pazihc.
SHEET NUMBER
... PV-6
1 SOLARMOUNT :E=UNIRAC
1.
BETTER DESIGNS ,Py�
1• •1 ' ' '' I I 1 1 1 TRUST THE INDUSTRYES BEST DESIGN TOOL
CONCEALED UNIVERSAL o
$lair The design process..Im aycry moleet in out u Buddei on line design tool FNDCLAMPS .�
I I I ■■� 1 I 1 -
IPs"a,dioal Way to savaaimearA monry.
1 I I' � I I 1' 1 I 11 G a •a
BETTER SYSTEMS
ONE SYSTEM-MANY APPLICATIONS _
Qmckly set modules Queh to the roof on steep pltcl adaaols 0nud a We,xn ely
of modules In Palmd or 4apdsca Till this nn up Ifal� a or to slow cools END CAPS INCLUDED
an
Opmponenls av IaTdain nll,char anddalk linishesto apt cove yoiu des gllua uljls n WITH EVERY ENDCLAMP
and ueslheIn s,
BETTER RESULTS `
E
000
MAXIMIZE PROFITABILITY ON EVERY JOB
CONCEALED TDlst liamae to helpywoorno ehothzyst¢m and IaLolwsls lrpm the Into No lo¢t
UNIVERSAL quoted to The hmeyoultcapis;get all the,lool,faslennstalls LCssWaste.Mote Prolih.
C(AMfoS UNIVERSALSELF
aUNtrint BETTER SUPPORT STANDING MIOCLAMPS
��J WORK'WITH THE INDUSTRIES MOST EXPERIENCED TEAM
Prolesvonal support!atpralosslonal plslallus and designers You have access to PROJECT NAME
our Itc4tical support and,—la groups Wimlove,yam sopped pacts wave.got _ J _}
1 l •1 OPTIOIIAL YEAH you covered Visit Uauacdo@/solarmounl loi mnromlormahoq
. ' i I ERONTTRu1' ILfISTSI •
N1LflAAl Iw I ' U-BUILDER ONLINE DESIGN LIj •
TOOL SAVES TIME&MONEY
o
BONOISNi&CROIli0kK0 H I It Von[design nn rac:epni
9 UL2703 sYs LTASs PARb4 ui •
• Coll
1 5 •
UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT
iR
m cc)- =
„
UNAfAICNlD I C[Rllll[0 (NGIn[(B(fiG BWIIgAOIC DfSIGK P[BIAII .
r I%P-IRICIIC[ PUAIIIY' E%CFIIFNC( WAPg91IiY COOIS OnCUACI11AI10[1. ■
a
TECHNICAL SUPPORT CERTIFIED QUALITY PROVIDER BANKABLE WARRANTY
Unuapslci,hncal supnnii loam is dcdicalcdlo;answaiilw, Unnxrs the pnlVPV)mm�llmg veminrivilh,,ISO Don llexseypulplotesl lotlaircc Uiniae liasllm
nudshons&ntldressotg issues�ocealllta Anonlinu enllDealrelsfo,90010000140OL2004ml ORSAS financmTsheAgihlohack um produotsntlln0vcyc+pak
SHEET NAME
THE PROFESSIONALS' CHOICE FOR RESIDENTIAL RACKING Ihmrydldocumonisluudrug egemECrl,g wally
Writ To xul lhmaansThedel velihalgheslslammds e-ee-pal eahly S0LARyw aTo;=,dbya25yl
slampad.lellcrsaud lrehngatdatashpcls gscaltY Writ Tom Anil llmrt nA iFysc aaiUhcafansitenimatmlc estcphnimlglml ly:SOIARRfOUB,Isttrmmdbya8ytwy SPEC SHEET
snlpldFasMmAemnlingynd"ryoltdplanntgGocass cuamllercc:+n)tanunihntdtolirslsLnshlisnesspzst IimdedluodudCrananlyanda5ycarhdelgAhiulfiyutaily
u+ariur'urmoravnr4u4WrMrr�imuiuWu@YiiYwru.nuYeeJlWkr4tlnibuyu T�wvwvwm.�nrWYur+s.w�Wuurw.rN.MrwARJOaw...M✓rerfenmlmtmwX�. .r�+�w..wuwmwr'
BEST INSTALLATIONEXPERIENCE-CURB APPEAL-COMPLETESOLUTION•UNIRACSUPPORT ENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN ANSI B
FOR QUESTIONS OR CUSTOMER SERVICE' VISIT UNIRAC.COM OR CALL 4550'5) 248 2702 FUR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL(505)248 2102.
Unirac State Letter-NY HARVEST' -) .
Tectonic-1 Tectonic TectonlAu9 st12,2024
HARVEST POWER LLC
2941 YISLIP
5�
August 12,2024 • Metal Roof:Standing Seam Attachments,PM-9000s,and PM Adjust Slotted At- kh
• Tile Roof:Solar hooks,Flashkit Tile Replacement(TR) y2 0
Unirac
-Builder Tool should be used under the responsible charge of a registered
Attn:Engineering Services Department The U
1411 Broadway Boulevard NE professional engineer required by the authority having jurisdiction.The design tool
Albuquerque,NM 87102-1545 and Unirac do not evaluate the existing roof structure,or the PV panels themselves. A
TEL:(505)242-6411 See the construction and installation drawings and manuals for additional 0z 8 0�
information provided by Unirac. Or ri
RE:ENGINEERING CERTIFICATION LETTER FOR THE UNIRAC SOLARMOUNT(SM) Sincere) oN
ROOF PV PANEL SUPPORT SYSTEM y, OF NE4y
STATE:NEW YORK 4� Y oescwPnon DATE REV.
TECTONIC WORK ORDER 8:12557.25 Tectonic ytP°O A.Ov4�09� a ne.reramr ,v,vzoxa o
+ = m +
The Unirac SOLARMOUNT(SM)Photovoltaic Panel Support System is a proprietary o ` 1 v_ cc
photovoltaic panel support system that is installed on a roof. Tectonic z
Engineering Consultants, Geologists & Land Surveyors, D.P.C. (Tectonic) has mF
reviewed the SM design methodology along with the U-Builder tool;a Unirac online a�tzae yea
design tool.The review included the following SM products,SM Light,Heavy Duty, SIGN° 08/12/2024
and Standard rail with both the standard and pro hardware.
Antonio A.Gualtieri,P.E.
Tectonic has determined that the design is a rational approach and follows the Executive Vice President
structural requirements of the following reference documents:
Codes/Standards: PROJECT NAME
• 2020 Building Code of New York State.
• 2018 International Building Code by International Code Council. Q 0
• ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures,by j C) J
American Society of Civil Engineers with provisions from SEAOC PV-2-2017. 0 O
• 2020 Aluminum Design Manual,by Aluminum Association. W LCV o J This Z:
that
and letter
componentssdirectlyerelated structural
Unirac's system are gin compliance connections,
the U a "I W O
above codes. The design methodology is acceptable under components and O z } p U.) U)
cladding loads associated with the building's roof structure when the system is Y O Z N ll O
installed in accordance with manufacturer specifications.If the loading criteria does J (7 Y }
not meet Unjrac's specifications, owner shall contact Unirac for a site-specific W W .�- F-
certification.
� oOoJ
Q �F_ oF- F-
Attachments approved for the SM system to the structure include the following
and is installed per Unirac s U-Builder report and installation guides: Q d =
• Shingle Roof:L-Foot Flashkit Pro,Standoffs,Flashloc Comp,Flash Loc Duo, Q
and Flash Kit Pro SB
SHEETNAME
Project Contact Info Project Contact Info
SPEC SHEET
127911oute=1 Newbwgh.NY12559 1279Rmte300 I Newburgh,W12550
845.667.6656 Tel 1845.567.8703 Fax e<5.567.6656 TM 1 645.567.8703 Fax
SHEET SIZE
tmto'd-n®medngtom teemNcen96xedng.cem page of ANSI B
Equal Oppodlniry EVoYer Equal Oppodumry FmDloYer
11"X 17"
SHEET NUMBER
PV-8
OF SOUIyOIo �SFSOUTHOLDTO ".BUILDIN EP/�,/T.
coulm, 631-765-1802
INSPECTION
[ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING
[ ] FRAMING/STRAPPING [ ] FINAL
f ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL)
[ ] CODE VIOLATION ] PRE C/O [ ] RENTAL
REMARKS:
DATE
57)
�� FFD BUILDING DEPARTMENT- Electrical Inspector
TOWN OF SOUTHOLD
'` N Town Hall Annex- 54375 Main Road - PO Box 1179
o _ � Southold, New York 11971-0959
Telephone (631) 765-1802 - FAX (631) 765-9502
1 ' iameshCc)southoldtownny.gov 7 seand(a)_southoldtownny.gov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All Information Required) Date: 11/12/2024
Company Name: Harvest Power LLC
Electrician's Name: Carlo Lanza
License No.: ME-68518 Elec. email: hppermitting@harvestpower.net
Elec. Phone No: (631) 647-3402 01 request an email copy of Certificate of Compliance
Elec. Address.: 2941 Sunrise Highway, Islip Terrace, NY 11752
JOB SITE INFORMATION (All Information Required)
Name: Gabriel Kochmer
Address: 780 Legion Avenue, Mattituck, NY 11952
Cross Street: Pacific Street
Phone No.: (312) 218-5599
Bldg.Permit#: 5 1 51o5 email:gkochmer@gmail.com
Tax Map District: 1000 Section: 142 Block: 2 Lot: 13.1
BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
Installation of a 4.60 kW solar PV system with (10) REC460AA roof-mounted panels.
Square Footage:
Circle All That Apply:
Is job ready for inspection?: ❑ YES ❑✓ NO ❑Rough In ❑✓ Final
Do you need a Temp Certificate?: ❑� YES ❑ NO Issued On
Temp Information: (All information required)
Service Size❑1 Ph❑3 Ph Size: 200 A #Meters 1 Old Meter#
❑New Service[:]Fire Reconnect[:]Flood Reconnect❑Service Reconnect❑Underground ✓❑Overhead
# Underground Laterals 1 FJ2 M H Frame Pole Work done on Service? Y N
Additional Information:
PAYMENT DUE WITH APPLICATION
PERMIT# Address:
Switches
Outlets
GFI's
Surface
Sconces
H H's
UC Lts Fridge HW POOL
Fans Mini Fr. W/D PanelPump
Exhaust Oven Sump Heater
Trnsfmr
Smokes DW Generator Salt Gen.
Carbon Micro GrbDis Water Bond
Lights
Heat Pucks ERV
HOT TUB/SPA
Inst Hot DeHum Transfer Disc
Combo Cooktop Minisplit Blower
AC AH Hood Blower
Service Amps Have Used
Sub Amps Have Used
Comments