Loading...
HomeMy WebLinkAbout52712-Z �o��pF SOplyo`o Town of Southold * * P.O. Box 1179 kiA? 53095 Main Rd Ulm. Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46955 Date: 04/07/2026 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1220 Old Farm Rd Orient, NY 11957 Sec/Block/Lot: 25.4-11.10 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 01/20/2026 Pursuant to which Building Permit No. 52712 and dated: 03/03/2026 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof mounted solar on existing accessory garage as applied for. The certificate is issued to: Keith Morton, Christine Morton Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 116774 3/10/2026 PLUMBERS CERTIFICATION: uthonzed Signatur r �o4,AofSoaryo(c TOWN OF SOUTHOLD BUILDING DEPARTMENT ' SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52712 Date: 03/03/2026 Permission is hereby granted to: Keith Morton PO BOX 134 Orient, NY 11957 To: Install roof mount solar on existing accessory garage as applied for. Disconnects must be located on the exterior, labeled,and readily accessible. Premises Located at: 1220 Old Farm Rd, Orient, NY 11957 SCTM# 25.-4-11.10 Pursuant to application dated 01/20/2026 and approved by the Building Inspector. To expire on 03/02/2028. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 CO-RESIDENTIAL $100.00 Total $200.00 -------V7 — ------------ Building Inspector NASSAU ! ELECTRICAL SUFFOLK jINS PECTORS 159 Route 25A, Building 1 Suite B Miller Place,NY 11764 Telephone:631 495 8136 - Fax:631 509 4538 • E-Mail:Requests@SuffolkBEI.com CERTIFICATE OF ELECTRICAL COMPLIANCE Applicant: Green Logic Certificate No.: 116774 Rough In Inspection Date: Final Inspection Date: Mar 10,2026 Application No.: Building Permit No.: 52712 County Tax Map No.: 1000 25 4 11.10Y This Certificate of Electrical Compliance is limited to the inspection and&rn 6e, f electrical equipment and/or work described below,installed on behalf of the applicant named above,located at thiD$iAmise of and not after the final inspection date above: A� � 2026 Owner: Keith Morton Site Location: MORTON,1220 Old Farm Road,Orient,NY 11957 Owner's Address if different): Residential 19 Indoor ❑Basement ❑Service ❑Shed O Commercial 0 Outdoor ❑First Floor ❑Pool ❑Hottub ❑New ❑Renovation ❑Second Floor O Attic ❑Garage ❑Addition ❑Survey 0 PV Solar ❑Generator ❑Conversion - - ----------- O Signs ❑Battery Storage ❑Safety Inspection Other: INVENTORY Single Phase Heat 0 Duplex Recpt Ceiling Fixture Dual Func Breaker Three Phase Hot Water GFCI Recpt Wall Fixture Smoke Main Panel AC Cond Single Recpt Recessed Fixture CO Detect Sub Panel AC Blower Range Recpt 0 LED Lighting 0 Smoke CO Combo Transformer Appliance Ckt Dryer Recpt 0 Emergency Time Clock Disconnect 0 Switches Twist Lock Exit Fixtures 0 Pumps 0 GFCI Breaker Heat Pump Electric Heat 0 Pool Luminaire 0 Exhaust Fan 0 Other Equipment:System Size:4.140 kW Qty:9 Desc:rec460aa pure-rx Qty:9 Desc:enphase lg8x-80-m-us The electrical work and/or equipment described above were inspected and was found to be in compliance with local, state and national electrical code requirements and this office. Applicant: Green Logic License No.: 43858-ME Date Printed: Mar 11,2026 Inspected By:Joe Coppola Signature: 3�'Y SOUTyO TOWN OF SOUTHOLD BUILDING DEPT. coorm, ,o . 631-765-1802 INSPECTION- - I FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ I SULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL S9k je! [. ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT.PENETRATION [ ] ELECTRICAL (ROUGH) [ ] 'ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: D - - Cr o DATE INSPECTOR Y D A M E S J. S TOUT A R C H I T E C T & Assoc . 2 G R E G L A N E E AST N0RTHP0R TN. Y. 631 - 8 58 9388 Post Install Letter March 9, 2026 RE: Keith Scott Morton 1220 Old Farm Road Orient, NY 11957 To Whom it may concern: This letter is to confirm that as of this date, March 8, 2026 I, James J Stout, NYS license 021633 have visually inspected the placement and installation of the roof top solar panels at the above listed address.The solar panels have been installed as per manufacturers' guidelines and specifications. The racking system design and installation complies with all applicable codes. The installation was done as per the approved Building Department. The analysis of the documents supplied by the client relies on sound engineering judgment and relevant experience. However, regardless of the professional's qualifications or thoroughness of the investigation, preexisting conditions cannot always be anticipated beyond the scope of direct observation. No additional guarantees, whether expressed or implied, are provided regarding the professionals' recommendations outlined in this letter. This certification letter must be presented to the municipality within 120 days of the issuance date to ensure compliance with safety procedures and continuity of service. Thank you for your cooperation in this matter. James J. Stout aeD Aqc 4%, 21 y FIELD INSPECTION REPORT I DATE COMMENTS b FOUNDATION (1ST) ------------------------------------ O [ FOUNDATION (2ND) — z � o AZ O V ROUGH FRAMING& pn PLUMBING r 1 �r INSULATION PER N.Y. STATE ENERGY CODE G 2 . FINAL ADDITIONAL COMMENTS yy euI so Pd Ce r c � Z M t� N y o z y x d b y �o�suFFocK�oG � TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 Telephone(631)765-1802 Fax(631.) 76579502 bttps://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT y For Office Use Only PERMIT NO. Building inspector. Applications and forms must be filled out in their entirety Incomplete r ;.applications will notbe'accepted: Where;th'e'Appli: rs n(t`the owner;an �„ Owner's Authorization form(Page 2)shah be completed. Date:8/13/2025 OWNER(S)OF PROPERTY: Name:Keith Morton SCTM#1000-25-4-11.10 Project Address::1220 Old.Farm Road,. Orient, NY 11957 Phone#: Email: 917-923 5494 keith 9 keithscottmorton.com Mailing Address: ,,.. . : . CONTACT PERSON: Name Barbara_- GreenLOgic LLC 'Mailing Address:g77 North Sea Road, Southampton, NY 11968 Phone#:631-771-5152 x117 . Email:Barbara@ Greenlogic.com 'DESIGN PROFESSIONAL INFORMATION: Name: ., an 45 Mailing Address: OZ V(F E. /—C ' I1-3 I Phone#:IO�1_ g q .g$ Email: .CONTRACTOR INFORMATION: Nam61,GreenLOgiC.LLc. Mailing Address:97 P North Sea.Road, Otharripton, NY 11968 n:o TEmail:AMPGreenlogic.qom DESCRIPTION OF PROPOSED CONSTRUCTION O..ew Structure,.DAddition BAlteration ❑Repair ❑Demolition Estimated Cost of Project: i.9 Other Solar Panels dh garage Will the lot be re-graded?:' DYes iiNo Will excessfil)be removed from premises? (]Yes ®No .';PROPERTY INFORMATION.-; Existing use of property: Intended use of property: I I Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes No IF YES,PROVIDE A COPY. B Check Box After!Reading: The owner/contiacGorfdesigdprofess onaI is responsible for all drainageand siorm water issue as provided by ` - Chapter 236 of the Town Code_APPLICATION IS HEREBY MMEtti the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance ofthe Town of-Southold,Suffolk,County,NewYork and other applicable Laws;Ordinances or;Regulations,for the construction of buildings, additions,alterations or for;removal or demolition as Herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authoraed insptoYors on premises and in bulding(s)for' inspections.False statements made herein are 'pimishableasaiClassAmisdemeanor Pursuant ta Section 216ASofthe,"York StatePenal Law. Application Submitted By(print name):GreenLogic LLC BAuthorized Agent ❑Owner Signature of Applicant: ,/ Date: l C� �-49 STATE OF NEW YORK) SS: COUNTY OF Suffolk Nesim Albukrek being duly sworn,deposes and says that(s)he is the applicant ((daMe'of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this ( day of Jd I(1{."(A .2O ?(A_ Notary Public BARBARA A CASCIOTTA PROPERTY OWNER AUTHORIZATION NotaryPubllc-Stat®of New York No.OICA4894M (Where the applicant is not the owner) Cualilied In Suffolk County Commisslon Expires May 11.202? residing at Z�20 r>G!J .54 do hereby authorize GreenLO91C LLC to apply on my behalf to the Town of Southold BuildingDepartment for approval as described herein. Owner's Signature Date Keith Morton Print Owner's Name GREENLOGIC® ENERGY January 14, 2026 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Project Info: Keith Morton 1220 Old Farm Road Orient, NY 1000-25-4-11.10 Dear Building Inspector: Please find attached a building permit application to install a roof mounted solar photovoltaic(PV) electric system on the detached garage. In connection with this application, please find attached: • Building Permit application with owner authorization • 2 Surveys of the Premises • 4 Engineer's Reports • 2 Three Line Electrical Drawings • 2 Spec.sheets of the solar panels/inverters • 2 Spec.sheets for Racking System • 2 Spec.sheets for Monitoring System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$200($100 Building Permit/$100 CO) Please let us know if you need anything else in connection with this application. Yours truly, J3a4&na 'ea6cioUa Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 ext. 117 GREENLOGIC LLC • www.GreenLogic.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd., Suite 3 200 S. Service Rd.,#104C Southampton, NY 11968 Rosyln Heights, NY 11577 GREENLOGIC® ENERGY March 26, 2026 The Town of Southold F�. MAR g 1 2026 Building Department t 54375 Route 25 P.O. Box 1179u�� ���� Southold, NY 11971 Project Info: Building Permit No. 52712 Keith Morton 1220 Old Farm Road Orient, NY To the Building Inspector: Enclosed please find the Electrical Certificate and Engineer's Certification Letter for the above referenced address. Can you please close the building permit and send the Certificate of Occupancy after inspection? Please let me know if you have any questions about the installation. Sincerely, 53a 46a 4ac ealas cioffa Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 Ext. 117 GREENLOGIC LLC .www.GreenLogic.com Tel: 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd., Suite 3 200 S. Service Rd.,#104C Southampton, NY 11968 Rosyln Heights, NY 11577 SURVEY OF PROPERTY e, a t ORIENT TOWN OF SOUTHOLD SUFFOLAK COUNTY, ME 1000-25-04 11..t0 iorQ SCALD 1*-40' vats, MAY It. 2016 .XINE 27, 2016(REWSAVS) } MAY 14, 2Ot8 5 + AWAY 25. 2018(HELL LOWED) .X1NE A 2018(CC DETAIL) � .itlLY 26; 2018(SCDHS LCUMENTS) r�xae• AUGUST 9, 2018, (REWSIONS) tPar40'40'L MI WA q 1 ! VACMr MAW r +KM r ar d I i i . f.WACC S CE _ to sMscarn ni srsam astx sr. ... LL swnayo r"J.rrs ROAD r o� saAaTA>?y L7E�lt"V ! N�N�tlAryk��'FANti' 4 SEDROW Dri£idA&G OY�Et _ 1 XfY VAC Af ♦ «s+rAsr � r nvwA t t W tea,-umarrorr 'Xy-aeawwr Nt#S9 Rom. ess-aa-as raa mwr&WON cosy OL aa• r Wow u r A& mow nw m L'DA x"W su a PA(Z aWXV Inc MMKW S"$P ur rAOt a p" Fw$d K"SAND q rY ��pF ldEl4y M$t�C�Y LOT MaiMM figlf ro WAP Cr LROMW Srgtrr FARM' 0"AMNS a CC+tW(M Lft=A4£WE;&M=TO MAW W av nBa 24 204 AS"t AKt. Wft uAIW eewarm'mrcsuOW Anwav'MA r" SscrrrAS vat MCWN 72W-StmLWtS'*1 Z ALL rumuJXus «'�" Ylt:ma 4sard t4i3l W ARr VAW FOP 00 NAB Acv O, ,p9mol oarY s.4 , AAC: MV MAP snxdAru� INC rsur cAc a nr pAii AT AQr FAr(ast)ras-1�s� 1' gar, J A M E S J. S TOUT A R C H I T E C T & ASSOC . 2 G REG L A N E L'' AST NORT11P0RT N. Y. 631 — 8 58 9 3 a 8 COMPLY WITH ALL CODES OF Letter of Certification NEW YORK STATE&TOWN CODES 01ricense AND CONDITIONS OF January 6,2026 SOUTHOLD TOWN ZBA RE: Morton ResidenceSOUTHOLD TOWN PLANNING BOARD 1220 Old Farm RoadOUTHOLD TOWN TRUSTEES Orient, NY 11957 .Y.S.DEC RETAIN STORM WATER RUNOFF SOUTHOLD HPC PURSUANT TO CHAPTER 236 To Whom It May Concern: CHD OF THE TOWN CODE. I, James J. Stout, registered architect 021633 would like to submit the following. I have inspected and analyzed the roof structure with the information provided to me by the solar company for the above-mentioned address and have determined the structure and the panel attachment to be adequate to support the new additional load imposed by the proposed solar panel system and is in compliance with 130mph wind design load as per 2025 Residential code of NYS (RCNYS), 2025 building code of NYS(BCNYS) residential code, 2025 Energy conservation construction code of NYS (ECCCNYS)and the IRC 324 and 2023 NEC. The analysis of the documents supplied by the client relies on sound engineering judgment and relevant experience. However, regardless of the professional's qualifications or the thoroughness of the investigation, preexisting conditions cannot always be anticipated beyond the scope of direct observation. No additional guarantees,whether expressed or implied, are provided regarding the professional recommendations outlined in this report. The 2"x 10"@16"o.c. roof.rafters will provide adequate suparL 'APPROVED AS NOTED DATE-4 # /T FMBY -'' NOTIFY BUILDING DEPARTMENTA 631-765-1802 8AM TO 4PM FOR THE Q� 021 FOLLOWING INSPECTIONS: 33 yo 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE OCCUPA 2. ROUGH-FRAMING&PLUMBING 3. INSULAI"ION r 4. FINAL-CONSTRUCTION MUST USE IS UNLAWFUL BE COMPLETE FOR C.O. WITHOUT CERTIFICATE ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW OF OCCUPANCY YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS ( GRE EN LOG IC° ENERGY GreenLogic,LLC Approved Morton,Keith 1220 Old Farm Road Orient,NY 11957 Surface#A: Total System Size:4.140kW 1 circuit of 9 on a 20A breaker Azimuth:174' Pitch:18° Monitoring System: N EnPhase Panel/Array Specifications: Panel:REC460AA PURE-RX o Racking:IronRidge Panel:68.0"X 47.4" Array:35'9 5/8"X 5'8" Surface:46'9"X 21'4" Legend: 9 REC Alpha Pure-RX 460W 9 IQBX Microlnverters Iron Ridge XR-100 Racking • 18 S5!S Clamps Drexel Metal Aluminum 032 GA Standing Seam 15 1/8"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:35!,IronRidge,REC, EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: f f�l 02 t�33 yOQ Drawn By:MA Drawing#1 of 5 Date:1/2/2026 REV:A Drawing Scale:1/8"=1.0' GREENILOGICO ENERGY GreenLogic,LLC Approved Morton,Keith 1220 Old Farm Road Orient,NY 11957 Surface#A: Total System Size:4.140kW 1 circuit of 9 on a 20A breaker Azimuth:174° Pitch:18° Monitoring System: EnPhase 1�— Panell/Array Specifications: Panel:REC460AA PURE-RX o Racking:IronRidge Panel:68.0"X 47.4" Array:369 5/8"X 5'8" Surface:46'9"X 21'4" Legend: ® 9 REC Alpha Pure-RX 460W 9 IQBX Microinverters Iron Ridge XR-100 Racking • 18 S5!S Clamps Drexel Metal Aluminum 032 GA Standing Seam 151/8"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:S5!,IronRidge,REC, EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: q-1\ �sJ Drawn By:MA Drawing#2 of 5 Date:1/2/2026 REV:A Drawing Scale:1/8"=1.0' 0 3�� REENL f ° ENERGY GreenLogic,LLC Approved Morton,Keith 1220 Old Farm Road Orient,NY 11957 Surface#A: Total System Size:4.140kW 1 circuit of 9 on a 20A breaker Azimuth:174° Pitch:18' Monitoring System: N EnPhase Panel/Array Specifications: Panel:REC460AA PURE-RX Racking:IronRidge Panel:68.0"X 47.4" Array:35'9 5/8"X 5'8" Surface:46'9"X 21'4" Legend: 9 REC Alpha Pure-RX 460W 9 IQBX Microlnverters Iron Ridge XR-100 Racking • 18 S5!S Clamps Drexel Metal Aluminum 032 GA 1 Standing Seam 151/8"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:S5!,IronRidge,REC, EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: r1 of e ` �2163 ypQ^ Drawn By:MA Drawing#3 of 5 Date:1/2/2026 REV:A Drawing Scale:1/8"=1.0' No Vent Piges Will Be Covered By The Solar Array E L® ICE ENERGY Legend: GreenLogic,LLC Approved Morton,Keith AR-Access Roof AP-Access pathway,36"minimum width SVO—Setback at ridge 1220 Old Farm Road per R202 definitions per R324.6.1 as per R324.6.2.1 Orient,NY 11957 Total System Size:4.140kW 1 circuit of 9 on a 20A breaker Detached Garage INTIXTIXTIXTIfIxImix Azimuth:174" Monitoring System: N EnPhase 9 REC 460W Panel/Array Specifications: Panels Panel:REC460AA PURE-RX Racking:IronRidge Panel:68.0"X 47.4" I Legend: I � 9 REC Alpha Pure-RX 460W ! 9 IQ8X Microlnverters I — Iron Ridge XR-100 Racking AP l • 18 S5!S Clamps Drexel Metal Aluminum 032 GA 0' 0� Standing Seam 15 1/8"O.C. -----——— Notes: Main House Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:S51,IronRidge,REC, SVoMX XrF EnPhase Added Roof load of PV System:2.32psf Engineer/Architect Seal: i I Existing PV I ��RED C Arrays ! svo C5 �g 1. 7� 40 I � I AP � �q '021 bg3 yoQ i i F BF tdV-T1 Meter Drawn By:MA Drawing#4 of 5 \ Date:1/2/2026 REV:A \cam Drawing Scale:3/64"=1.0' '9"'z��GREENLOGICO ENERGY GreenLogic,LLC Approved Morton,Keith 1220 Old Farm Road Orient,NY 11957 JOB MATERIALLIST------- Total System Size:4.140kW I circuit of 9 on a 20A breaker Azimuth:174* Material ---Rail Material List- (L. Monitoring System: EnPhase Panel/Array Specifications: S5!S Clamps 18 Panel:REC460AA PURE-RX Racking:IronRidge Panel:68.0"X 47.4" Legend: 9 REC Alpha Pure-RX 460W -------- 9 IQ8X Microinverters ------- Iron Ridge XR-1 00 Racking 0 18 S51 S Clamps Drexel Metal Aluminum 032 GA ---------- ------ Standing Seam 15 1/8"O.C. Notes: Number of Roof Layers:I Height above Roof Surface:4" Materials Used:S5!,fronRidge,REC, EnPhase Added Roof load of PV System:2.32psf EngineerlArchitect Seal: D C 0. • Drawn By:MA Drawing#5 of 5 Date:1/2/2026 REV:A Drawing Scale:3/64"=1.0' EQUIPMENT—----.__—.—,._....,...--- _ mm EXISTING SER14CE r C ' i PV—SA—s A i'm` ° tCIA ' &} M 0 ., s — AC—COMBINER PANEL 1 I � PV--SA-2 AC—Ci�f�-1 AC DISCONNECT I (Pay LOAM ONLY) • • a ® A I AC--QSC-5 i TE81 ia f ' 1 , t I M(R-1MAIM I 1 II I' g I ! ° EI ' I I F to Pd lI I I I IEGC i II I 1 # jlp EGC I N r fI i I r # I i kI I { &t (1( I I I EXISTING AC PANEL", t II Iy I I I I EXISTING IRREVERSIBLE SPLICE _ ..._— � 1 GEC �� I GEC 8.280kW DC 6.84OkW AC PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Morton, Keith 1220 Old Farm Road r GREENLOGIC ENERGY Orient, NY 11957 ELIMINATING THE COST F ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 3 Drawing No: 3LD1 Revision: 1 Revised:8/25/2025 EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PV SUB-ARRAY REC460AA Pure-RX ENPHASE IQ8X-80-M-US, 1-CIRCUIT OF 9 MODULES PV-SA-2 PV SUB-ARRAY REC460AA Pure-RX ENPHASE IQ8X-80-M-US, 1-CIRCUIT OF 9 MODULES ELECTRICAL LOAD SUMMARY AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 4140 WATTS 211-264 VAC 17.7 A AC 240 V,AC PV-SA-2 4140 WATTS 211-264 VAC 17.7 A AC 240 V,AC PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Morton, Keith 4 1220 Old Farm Road = Orient, NY 11957 ELIMINATING THE COST O ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 2 of 3 Drawing No: 3LD1 Revision: 1 Revised:8/25/2025 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION AC-CMB-1 AC COMBINER PANEL 250V, 100A, NEMA-1, 1-PH, 3-WIRE BKR-1 CIRCUIT BREAKER, PV-SA-1 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-2 CIRCUIT BREAKER, PV-SA-2 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 250V, 60A, NEMA31R�FUSED; FUSE RATING: 50A CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4" PVC-40 12 / 6 B THWN-2 1-1/2" PVC-40 4 / 4 C THWN-2 1-1/2" EMT 4 / 4 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUITTO BE MIN. PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIREMENTS. 4.) NOTE: GROUNDING ELECTRODE CONDUCTOR TO BE#6 COPPER MINIMUM. PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Morton, Keith A 1220 Old Farm Road w. -NERG Orient, NY 11957 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 3 Drawing No: 3LD1 Revision: 1 Revised:8/25/2025 W� max. AFL IRON RIDGE XR Rail° Family Solar is Not. Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, .,, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing' enough to buckle a panel frame. XR Rails® are the structural backbone preventing these results. They resist uplift, � r protect against buckling and safely6r a and efficiently transfer loads into the building structure. Their superior "�`� spanning capability requires fewer roof attachments, reducing the21,1 eF £ number of roof penetrations a and the amount of > I r µ installation time. tj AV }4 Ix 4hil s Force-Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to �F 6 bend and twist.The curved shape of XR Rails@ is specially designed to increase strength in both directions while resisting the twisting.This unique � hr feature ensures greater security during extreme xi j weather and a longer system lifetime. �N.. N / th 5 d � Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials li XR RailsO are a IronRidgea offers All XR Rails@ are made of 6000-series a range of tilt le + aluminum alto then rotected with an i at compatible with '. g g y, p FlashFoot@ and zt options for flat anodized finish.Anodizing prevents surface other pitched roof ® roof mounting and structural corrosion,while also providing attachments. applications. a more attractive appearance. 3- XR Raile Family The XR Rail°Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail°to match. µ1.E ' XR10 XR100 XR1000 XR10 is a sleek,low-profile mounting XR100 is a residential and commercial XR1000 is a heavyweight among rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle no snow.It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. 6'spanning capability 10'spanning capability 12'spanning capability • Moderate load capability Heavy load capability Extreme load capability • Clear&black anodized finish Clear&black anodized finish Clear anodized finish • Internal splices available Internal splices available Internal splices available Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.* Values are based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. 90 � None 'I � z r 140 XR10 s� XR100 � '1000 160 9 ' 90 120 20 a 140 160 r 90 [I l 30 160 i a 90 x f 40 160 E A� <`x 80 160 120 160 'Table is rnLant to be a simplified span chart for conveying general rail capabikLes.Use approved certification ietters for actual design guidance. IRON RIDGE XR1000 Rail r' See Descrrption Length /i Rail Section Properties Property Value Total Cross-Sectional Area 0.582 in2 .66 Section Modulus (X-axis) 0.297 in' .46 Moment of Inertia (X-axis) 0.390 in Moment of Inertia (Y-axis) 0.085 in Torsional Constant 0.214 in3 i Polar Moment of Inertia 0.126 in I i i 1.99 APPROVED MATERIALS: 2.44. 6005-T6, 6005A-T61, 6105-T5, 6N01-T6 2.34 (34,000 PSI YIELD STRENGTH MINIMUM) .53 f .......I....................._........_..................................................... ......_...............; ....... 1.25 Clear Part Black Part Description/Length Material Weight Number Number XR-100-132A XR-100-132B XR100, Rail 132"(11 Feet) 7.50lbs. XR-100-168A XR-100-168B XR100, Rail 168"(14 Feet) 6000-Series 9.55 lbs. XR-100-204A XR-100-204B XR100, Rail 204"(17 Feet) Aluminum 11.60 lbs. V1.11 �.w...�...,,��,.. - _, :�• ._.�._�___..„> .Pew,�.u.,..�.�.�.�...�..,,,�,.. ,P'�;..�. Enphase Networking Enphase V,� Envoy The Enphase IQ Envoy" communications gateway delivers solar production and energy consumption data to Enphase Enlighten monitoring and analysis software for comprehensive, remote maintenance and management of the Enphase IQ System. With integrated revenue grade production metering and optional consumption monitoring, Envoy IQ is the platform For total energy management and integrates with the Enphase Ensemble"'and the Enphase IQ BatteryVA. Smart Eli Enables web-based monitoring and control • Bidirectional communications for remote upgrades •Supports power export limiting and . zeroexport applications MONA Simple • Easy system configuration using Enphase Installer Toolkit'"mobile app . Flexible networking with Wi-Fi, Ethernet,or cellular ..........................................._. . Reliable Designed for installation indoors or outdoors • Five-year warranty CERTIFIED To learn more about Enphase offerings,visit enphase.com En phase IQ Envoy MODEL NUMBERS ''Egphase IQ Envoy ` Erf '' q Envo?I aomrnunications gatevray-with in#egrated revenue grade PU- ENV IQ AtiA1 L40 - production �me#eriog(AAlSI 12 20 /-E v P}anii bpPtional pbnsumptron monatcr6ng,(+! 2 2t10A continu aus rate[! roductlon CT current transformer . . P ,. ACCESORIES(Order Separately) _ _ _ Enphase tVlabile,Canneet " P(ug andiplay industrial grade cellular 77 mod hip m W data plan for systerrr IT tci 60 CEt tMC}I)EM IVI i;(4G Based l TE M 5 year t3ata plan). mlcrc?iriVerters (Avaitabia,in the U Cara66 Iulaxico;,, uerto'Rico and the US Virgin GELLMCiDEM full B(4G based LTE M1/5 year;dataApia,}„ Islands Where there inadequate oellular service in#}ie insta((atian:area) Consumption Monitoring CT Split-core consumption CTs enable whole home metering. CT-200-SPLIT P�serilbleCammurieatEans.�tt � InstaMled at the IQ Fnvoy.l°or camsriunicatiois wtt61''iiphase�ncharga;- storage ' - COMM3 KlT C31 � �anri Enphase Eripower sr"aart��vitch Includes US>�`calsle fc7r�anoection to tt�' y Q ' Envo or Enphasd 1Q Cambiner artd allows wireless cammurrioation+rttiFr Encharga : POWER REQUIREMENTS O''VACs lit phase Pother requtrernents 20 P I 1 CL4 Max 2( overcurrent prcrtectian raga€red r Typical Consumption YP� Power surnption 5W CAPACITY turnba�_of mierainvertars polled Up to � ra00 MECHANICAL DATA t7irnensioris(bVxHxt1} ?1 x 7?6 x 4:S'cm(8 4 x a Weight 17.6 oz(498 g) 4�3 40 to�5 C °to 149 A7nb lent-temperature range ( " ) ` � z 40Yto 46°C{40 to 115 F)if lrrstalled in nc osute Environmental rating iP30.For installation indoors or in an NRTL-certified NEMA type 3R enclosure -� s a 2000 metals(6 560 fast) 'Altitude;. ...�_ Production CT Limitedf to 200A of continuous current;250A OCPD—72kW AC Internal aperture measures 19.36mm to support 250MCM THWN conductors(max) UL2808 certified for revenue grade metering Consumption CT Far electrical services tic 250A with paralle€runs up to 0 A= Internal aperture measures t184' t 0 96 { 1 3mm x 24 3Srirm)to support 3/0 TE tNN'con&ctor �- - UL2808 certifier],Mgr use at service en#rfzrfca fors rvir es u to 250Vat INTERNET CONNECTION OPTIONS integrated Wi Fi 80 1b gfn or 21 Ethernet< - 3i12,3,Cat5E{ Cat 6}UTP Ethernet cable(not included). 4 'd Nata'#hat an Pabil MM7 {4Q arCELL( 0� Not inq Lid e ` M llEsrbla intllatEpM©bile'Connectm d fora ons COMPLIANCE CA Gompiiarree � `UL 6101C)11 �• � � � �. � kVCA C22 2Ihio 0101 _ r I IEN_61a014CFREPt01 5°Class'l3,tC E5 00 i s 1,2010 ` �) N5C1(3,65 I, N61000 4.5,EN610i1Q 6 1 EN61Ct00 h-? " Metering' ANSI G12.20 accuracy.c[ass'OZ(PV pr6duction.anly) . v" To learn more about Enphase offerings,visit enphasexom 2021 D ipjh ase Energy.All i ighlis reserved.Enpl as—e'.the Enphe sea logo,1Q i-w•r;y,ands other traderna ks or seiv ce nan?es ire ttu>-trade- ;narks o`Er:.ol'iase En>ryy.Ine.D<'da sc,b;e- ..c ui?ar:.ge 6 30-2021 0 SOLAR'S MOST TRUSTED l�� REC REE ALPHA PURE-RX SERIES DATASHEET aYb 1 y ` J 4i �DULE CURRENT f 1 1 9 :S� `•S `-•',i- �� f s'_ c= ~ �- J��y.`x-f- .h. *�w�C"��a�.�.,=..'+1�"�_r"�'_-T.yi.1'�a��°t. fir" �° t "� `� .3.=. f: ';s.` A n f,�-. �� �".�✓..y,.r�-F��r'e's."aV`-.' �s.KX.� Y =7 � ?.�. � �,.. `• _-'�s.a,,. A'x as � `�.i`'`�Y'.° T .�.�-:� �� ►- - - '�,. �• .,es � ! .. ,. �- �CiF .�,. a r-ti` . _ . . MAX.EFFICIENCY 450 -470 WP . . , ,E r` • REL DATA5HEEIT SOLAR'S MOST TRUSTED Measurements In Inches GNERALC?�1A °t,,..,. •. _�ti ._.....a..e.,;z, r.A,va..,.;.v .u«'..w..a1 1.1 322 179 88half-cutbifacial REC heterojunctioncells . Cell Type - _. with gapless technology j 0.13,in.solar glass with anti-reflective surface treatment: Glass in accordance with EN12150' Backsheet Highly resistant polymer(Black) 669 66.9 ,I Frame -Anodized aluminum(Black) 4-part,4 bypass diodes, " Junction Box 1 IP68 rated,in accordance with IEC 62790 1. Staubli MC4 PV-KBT4/K5T4(12AWG) Connectors (• in accordanceWitti IEC 62852,IP.68 onlyzvhen connected 0A3�e f 12 AWG solar cable,66.9 in.+66.9 in. Cable in accordance with EN50618 j¢ is oa oca - i 7,1,11 Dimensions 68x 47.4 x 12 in. 22.4ft'{ ) *1 Weight 50lbs _ .�.:.:.... 27.43a.12 s os Origin_ M ade in Singapore: Y 3_ O ELtTR1CAL kaucco� � x�xAP> � cEic�T(an�s 3 _ R ��� � ., .-.�.w.. __. w_.. Power Output-PMAX(WP) 450 460 470 IEC 61215:2021;IEC61730.2016;UL61730 bo Sorting N! 0+10 0+10 0+10 ISO11925-2 Ignitability(EN 13501-1 Class E) Watt Class So g ( )' / j / ' . IEC 62716 Ammonia Resistance $ Nominal Power Voltage-VMpp(V) 54.3 54.9 55.4 IEC 61701 Salt Mist(SM15). w Nominal Power Current-IMpp(A) ,, 8.29 8.38 ,, 8.49 IEC 61215:2016 Hailstone(35mm) UL61730 FireType2 F Open Circuit Voltage-Voc(V) 65.1 65.3 65.6 ISO 1400 1;ISO9001;IEC4SQ01;IEC62941 Ln Short Circuit Current-Isc(A) 8.81 8.88 895 n�y, Power Density(W/ft2) 20.1 20.5 21.0 DVE °EIVua C E �❑ takegWay Panel Efficiency(%) 21.6 22.1 22.6 mt>etex k-ywEEc- .. Power Output PMAx(WP) .343 3S0 358 F_ Nominal Power Voltage-VMpp(V) 51.2 51.7 52.2 Z Nominal Power Current-I,.,(A) 6.70 6.77' 6.86 Open Circuit Voltage-Voc(V) 61.3 61.6 61.8 Short'Circuit Current Isc(A), 7.11 .- " 7.17 7,23 Standard REC ProTrust Values at standard testcond;ticns(STC:air mass AM 1.5,irradiancel000W,/m',temperature 7'i°F(25°C)).based on a production s°readw.th a tolerance of Pr.w,V°r?I t3% within one watt class.Nommalmodule operatingtemperature(NNIOT:aumass AMl5,iradance800W/m2,temperature 66'F(20'Q,w,ndspeed3.3 ft/s(I m/s)).^Where xxx 1ristalled'.by an REC`. No Yes Yes Ind¢ates the nominal power class(P,vc._)at STC above. Certified Professional IMUMRATING (+1E RATUtERgT(N CrS* System Au <zslw zs-sookw Operational Temperature 40 F-185°F Nominal Module Operating Product Warranty,(yrs) 20 25 25 System Voltage 1000•V Temperature 44°C 3 2°C Power Warranty(yrs) 25 25 25 Maximum Test Load(front) +7000 Pa(146 Ib/ft2) Temperature coefficient of PMAx 0.24%/K' Labor Warranty(yrs) 0,` 25 10 - o Maximum Test Load(rear) -4060 Pa(83Alb/ft2), Temperature coefficient of Voc -0.24%/K Power in Year 1 98% 98% 98% Max Series Fuse Rating 25 A Temperature coefficient of Isc 0.04%/K Annual Degradation, 0.25% 0.25% 0.25% Max Reverse Current - '25 A- '(hetemeratniracoefficmnis stated are inearvalues Power in Year 25 92/0 92% ° 92% m "See installation manual for mounting instructions Design load-Test load/L5(safely factor) �/- L^ p',..--�:•-�m1-•-- , The REC ProTrust VJarrar.N is only avai'able or.panels purchased through an REC to ,; r i�(l !"1JRIYIATI�rV'� Certified Solar Protessienai msla;ler Warranty conditions apply.See'wwwrecgroup. O com for more details r-4 Panels per Pallet 33 0 Panels per'40 ft GP/high g cube contai 594{l8 Pallets) -�.. ner W GNT k3EHAUlOR ,.,,..�.., i'. ..... a, Panels per 53 ft truck 792(24 Pallets) Available from: � _ Typical low irradiance performance of module atSTC: l �� Irradiance(W/m') Founded in 1996,REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean,affordable REC Solar PTE.LTD. solar power.As Solar's Most Trusted,REC is committed to high quality,innovation,and a low carbon footprint in the solar materials and solar 20Tuas South Ave.14RE C panels it manufactures.Headquartered in Norwaywith operational headquarters in Singapore,REC also has regional hubs in North America, Singapore637312 c A^� Europe,and Asia-Pacific. post@recgroup.com vnvw.recgroup.com ENPHASE. e . 1 Q 8X M i e ro i n ve rt e r easy to install Our newest I08 Series Microinverters are the industry's first microgrid-forming*,software-defined Lightweight and compact with plug- microinverters with split-phase power conversion capability to convert DC power to AC power and-play connectors efficiently.The brain of the semiconductor-based microinverter is our proprietary application- Power line communication(PLC) specific integrated circuit(ASIC),which enables the microinverter to operate in grid-tied or between components off-grid mode.This chip is built using advanced 55-nm technology with high-speed digital logic Fa"sterlhstallation with simple two wire and superfast response times to changing loads and grid events,alleviating constraints on battery cabling sizing for home energy systems. I08X Microinverter is the latest addition to this family,designed to support PV modules with high High produetiwty and reliability output DC voltage and cell counts,such as 80-half-cut cells,88-half-cut cells and 96-cells. Produces power even when the grid"is`: .down* e More than on million cumulative hours of'testing 25 Class II double insulated enclosure Optimized for the latest high-powered P.V modules Part of the Enphase Energy System, IQ8 Series Microinverters redefine IQ8 Series Microinverters integrate with reliability standards with more than one Microgrid foimlmg the IQ Battery,IQ Gateway,and the million cumulative hours of power-on Complies_with the latest advanced grid Enphase App monitoring and analysis testing,enabling an industry-leading support software. limited warranty of up to 25 years. Remote automatic updates for the latest grid requirements Configurable to"support a wide range, of grid profiles Meets CA Rule 21(UL 1741-SA)and IEEE ' 1547:2010(UL 1741,SB) • NOTE: Connect PV modules quickly and easily IQ8 Series Microinverters are UL Listed Ipe series Mic�omverters cannot be mi ed tivitt, to the I08 Series Microinverters with as PV rapid shutdown equipment and i previous generations of Enpfidse microinvarters(i07 integrated MC4 connectors. conform with regulations when installed series,I06 Series,and so on)In the same system., according to the manufacturer's o Mioromverters sMp with default settings that. instructions. mast North A nericas IEEE}15471hterc6nnection standard requirements.Region-specific ,adjustments"may be requested by an Authority Having Jurisdiction(AHJ)or,utility representative,ti':" according"Meets UL 1741 only when installed with IQ System Controller 2 or 3. to the IEEE 1,547.interconne'ctionstandard.An IQ Gateway is required to'makethese changes during mstaliatiop. ©2024 Enphase Energy.All rights reserved.Enphase,the a and CC logos,IQ.and certain other marks listed at nttp.//anphase.coin/trademar's=usaa e_guidelines are trademarks of Enphase Energy,Inc.in the U.S.and other countries. Data subject to change. IQ8X-MC4-DSH-00185-3.0-EN-US-2024-02-12 IQ8X Microinverter INPUT DATA tDO AT Commonly used module pairings'' w 320-540 - Module compatibility _ To meet compatibility,PV modules must be within the following maximum input DC voltage and maximum module I.. Module compatibility can be checked at https;//enphase,.com/installers/microinverters/calculator MPPT voltage range, v Operating range V 25-79.5 Minimum and maximum start'voltage v ->>, 30=79.5' Maximum Input DC voltage v 79.5 Maximum continuous operating DC current a< 10 Maximum input DC short-circuit current A 16 Maximum module 1„ A 13 Overvoltage class DC port - 11 DC port backfeed current mA 0 PV array configuration _ Ungrounded array;no additional DC side protection required;AC side protection requires a maximum of 20 A per branch circuit OUTPUT DATA IACI, UNIT 108X-80 0 VAC I08X-8O-M,;US ,: VAC Peak output power" VA '384 366 Maximum continuous output power VA 380 360 Nominal grid voltage(L-L) V 240 split-phase(L-L),180' 208,single-phase(L-L),120"4 Minimum and maximum grid voltage' V 211-264 183-229 Max.continuous output current A 1.58 1.73 Nominal frequency Hz 60 Exte nded frequency range ., -,- '` .Hz<.. 47-68 AC short circuit fault current over three cycles Arms 2.70 Maximum units Per'26 A'(L-L)branch circuit '10' 9 Total harmonic distortion ! <5 Overvoltage class AC port AC port backfeed current mA 18 Power factor setting - 1.0 Grid-tied power factor(adjustable) - 0.85 leading...0.85lagging Peak efficiency ! 97.3 97.0 CEC weighted efficiency % 96.5 96.5 Nighttime power consumption" mw 26 12,MECHANICAL DATA Ambient temperature.range =40°C to 65 C(-4O,F to149°FY Relative humidity range 4%to 100%(condensing) DC connector type Staubli MC4 Dimensions(H•W•D);Weight 212 mm MY)K 175 mm(6.9")•30.2 mm(1.2");1.1 kg(2.43 lb) Cooling Natural convection-no fans Approved for wet locations;Pollution degree Yes;PD3 Enclosure Class lfdouble-insulated,corrosion-resistant polymeric enclosure Environmental category;UV exposure rating NEMA Type 6;outdoor CA 161e21(UL 1741=SA);UL.62109-1,IEEE 1547:2018(UL:,1741-SB),FCC Part 15CIass B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-OL' Certifications This Product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017,NEC 2020,and NEC 2023 section 690.12 and 622:1=2018 Rule 64-218 rapid shutdown of PV systems for AC and'DC conductors when installed'according to the manufacturer's instructions. (1)No enforced DC/AC ratio. (2)Nominal voltage range can be extended beyond nominal if required by the utility. (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. (4)108X is not certified for use with Enphase Three Phase Network Protection Relay(NPR-3P-208-NA)and Is,therefore,designed IQ8X-MC4-DSH-00185-3.0-EN-US-2024-02-12 for single-phase operation only.Check with the local utility requirements if you wish to install single-phase inverters across three phases.