HomeMy WebLinkAbout51019-Z of souTyo!° Town of Southold * * P.O. Box 1179 �0 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46950 Date: 04/07/2026 THIS CERTIFIES that the building IN GROUND POOL Location of Property: 3420 Rocky Point Rd East Marion, NY 11939 Sec/Block/Lot: 21.4-8 Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 06/17/2024 Pursuant to which Building Permit No. 51019 and dated: 08/01/2024 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Accessory in-ground swimming pool fenced to code as applied for. The certificate is issued to: GH Assets 2 LLC Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 113567 10/14/2025 PLUMBERS CERTIFICATION: utho ize Sig afore �suFFot TOWN OF SOUTHOLD moo �y BUILDING DEPARTMENT s TOWN CLERK'S OFFICE goy • ,� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51019 Date: 8/1/2024 Permission is hereby granted to: 3420 RPR LLC 35 Howard Dr Coram, NY 11727 1 To: Install in-ground swimming pool at existing single family dwelling as applied for. Maintain mimimum 5 foot setback from property line to pool and equipment. At premises located at: 3420 Rocky Point Rd, East Marion SCTM #473889 Sec/Block/Lot# 21.4-8 Pursuant to application dated 6/17/2024 and approved by the Building Inspector. To expire on 1131/2026. Fees: SWIMMING POOLS-IN-GROUND WITH FENCE ENCLOSURE $300.00 CO-SWIMMING POOL $100.00 Total: $400.00 Building Inspector NASSAU ELECTRICAL ,` APR - 2 2026 V SUFFOLK INSPECTORS 159 Route 25A,Building 1 Suite B Miller Place,NY 11764 Telephone:631 495 8136 • Fax:631 509 4538 • E-Mail: Requests@SuffolkBEI.com CERTIFICATE OF ELECTRICAL COMPLIANCE Applicant: Prime Electric Inc. Certificate No.: 113567 Rough In Inspection Date: Final Inspection Date: Oct 14,2025 Application No.: Building Permit No.: 51019 County Tax Map No.: 21000 4 8 This Certificate of Electrical Compliance is limited to the inspection and compliance of electrical equipment and/or work described below,installed on behalf of the applicant named above,located at the premise of and not after the final inspection date above: Owner: Alain de Kerillis Site Location: 3420 Rocky Point Road,East Marion,NY 11939 Owner's Address(if different): Residential ❑Indoor ❑Basement ❑Service ❑Shed ❑Commercial ®Outdoor ❑First Floor ®Pool ❑Hottub 0 New ❑Renovation O Second Floor 0 Attic O Garage ❑Addition ❑Survey ❑PV Solar O Generator ❑Conversion ------------------------------------------------------------ ❑Signs O Battery Storage O Safety Inspection Other: INVENTORY Single Phase Heat 0 Duplex Recpt Ceiling Fixture Dual Func Breaker Three Phase Hot Water GFCI Recpt 0 Wall Fixture Smoke Main Panel AC Cond Single Recpt Recessed Fixture CO Detect Sub Panel 1� AC Blower Range Recpt LED Lighting Smoke CO Combo Transformer Appliance Ckt Dryer Recpt Emergency Time Clock Disconnect Switches Twist Lock Exit Fixtures Pumps Pool GFCI Breaker 0 Heat Pump 1� Electric Heat Pool Luminaire ® Exhaust Fan Other Equipment: The electrical work and/or equipment described above were inspected and was found to be in compliance with local, state and national electrical code requirements and this office. Applicant: Prime Electric Inc. License No.: 52402-me Date Printed: Oct 14,2025 Inspected By:Joe Coppola Signature: �'v fjf so # TOWN Or SOUTHOLD BUILDING DEPT. courm,��''i� 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS:_ AA DATE INSPECTOR �aOF so(/T�,o h� l� TOWN OF SOUTHOLD BUILDING DEPT. coorm, 631-765-1602 - NSPECTIONI [ ] FOUNDATION 1ST/ REBAR [ ] RO GH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] PXAL__� FRAMING [STRAPPING [ FINAL [ ] _ FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ]. FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] C DEE VI LATION [ ] PRE C/O [ ] RENTAL REMAR eq, Dwove" Awt,� �� _ . VV P� _ DATE INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) --------------------------------------- FOUNDATION (2ND) O ROUGH FRAMING& G PLUMBIN FRAMING O INSULATION PER N. Y. 7�1 STATE ENERGY CODE t FINAL ----------- 04, AD41T ONAL COMMENTS 10 1�410i __bws. lz�c A AZ —------------- =�aASUFFotK�oG�� TOWN OF SOUTHOLD—BUILDING DEPARTMENT H Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 Telephone(631)765-1802 Fax(631)765-9502 https://www.southoldtownny.gov _DateRecpived._.-..._. _.....,, ...;:= APPLICATION FOR BUILDING PERMIT For Office Use Onl MICE Y i PERMIT NO. 5 0 Building Inspector: JUN 17 2024 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not:the owner,an DIMMING DEPL Ownee-s.Authorizationform-(Page 2)shall be completed �,ram.,'..Let,-N Date:June 10, 2023 OWNERS)OF PROPERTY:. Name:pALERMO FLOORING INC SCTM#1000-021.00-04.00-008.000 ProjectAddress:3420 ROCKY POINT ROAD EAST MARION Phone#:631-655-2920 Email:matt@palermoflorringinc.com _ MailingAddress:4128 SUNRISE HWY OAKDALE, NY 11768 CONTACT PERSON: Name:TONI BAKKER Mailing Address:P.O. BOX 521 CENTER MORICHES NY 11934 Phone#:631-804-5551 Email:oni@kevinthepoolman.com DESIGN PROFESSIONAL INFORMATION: Name:SKEEZ INC DBA THE POOL MAN MailingAddress:P.O. BOX 521 CENTER MORICHES NY 11934 Phone#:631-878-7796 Ema1i:toni@kevinthepoolman.com_ y CONTRACTOR INFORMATION: Name:SKEEZ INC DBA THE POOL MAN MailingAddress:P.O. BOX 521 CENTER MORICHES, NY 11934 Phone#:631-878-7796 Email:toni@kevinthepoolman.com DESCRIPTION OF PROPOSED CONSTRUCTION ElpewStruct re ❑Addition ❑Alteration ❑Repai.f ❑Demolition Estimated Cost of Project: Other 3 W S; 1 $49000.00 Will the lot be re graded? ❑Yes El No Will excess fill be removed from premises? WYes ONO 1 PROPERTY INFORMATION Existing use of property:RESIDENTIAL Intended use of property:RESIDENTIAL Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ❑No IF YES, PROVIDE A COPY. []Check Box After Reading; The owner/contractor/design professional is:responsible for all drainage and storm water issues as provided by Chapter 236 of the Town"Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,'NeW York and other applicable Laws,Ordinances or,Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and,regulations and to admit authorized inspectors on premises and in building(s)for necessary_inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print na .TON I BAKKE R BAuthorized Agent ❑Owner Signature of Applicant: Date: 06/10/2024 STATE OF NEW YORK) SS: COUNTY OF oM1 -- ) fii° being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)ab a named, (S)he is the (C ractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly auth zed to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of l,�.n�. 20� Not STIN EZ of New York Notary Public-State No.o1VA6307026 PROPERTY OWNER AUTHORIZATION Qualified in Suffolk county (Where the applicant is not the owner) My Commission Expires June 30,2026 MATTH EW B RU N O residing at 35 HOWARD DR CORAM, NY 11727 do hereby authorize TON I BAKKER to apply on my behalf to wn Southold Building Department for approval as des ribed herein. (v) 2 2 V Owner's Signature Date MATTHEW BRUNO Print Owner's Name 2 Buildin!Department Application AUTHORIZATION (Where the Applicant is not the Owner) Matthew Bruno I, residing at 4128 Sunrise Hwy (Print property owner's name) (Mailing Address) Oakdale, ny 11768 do hereby authorize Toni Bakker (Agent) to apply on my behalf to the Southold Building Department. (Owner's Signature) ( ate M 6jJ' ew o (Print Owner's ame) ds aN 4 2 BUILDIN DEPARTMENT- Electrical Inspector oe Oepat 1d TOWN OF SOUTHOLD Bu`advTibAf all Annex - 54375 Main Road - PO Box 1179 T Southold, New York 11971-0959 .. . & Telephone (631) 765-1802 - FAX (631) 765-9502 ;; iamesh(a-southoldtownnv.aov — sea ndCEDsoutholdtownnyaov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 1/8/2025 Company Name: prime electric Electrician's Name: mike hunter License No.: me-52402 Elec. email: mike@primeli.biz Elec. Phone No: 6313875650 01 request an email copy of Certificate of Compliance Elec. Address.: 1380 broadway ave holbrook ny 11741 JOB SITE INFORMATION (AII Information Required) Name: gem hunter property solutions Address: 3420rocky point rd east marion Cross Street: main rd Phone No.: 6313875650 Bldg.Permit#: 51019 email: mike@primeli.biz Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): pool inspection 100amp pool panel with 4 pool lights, 1 pump,electric heater, 1 transfomer,and service gfi.water bond on pool piping Square Footage: Circle All That Apply: Is job ready for inspection?: RI YES ❑NO ❑Rough in ® Final Do you need a Temp Certificate?: ❑ YES 0 NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # U.nderground Laterals 1 2 H Frame Pole Work done on Service?. 0 Y N Additional Information: PAYMENT DUE WITH APPLICATION _IN ..e15 % S 15 tq-c,A- I Oct Nq / 25- % S FFOt ns BUILD�I _DEPARTMENT- Electrical Inspector G.. : Ott. 1,E�d`�g®ep�,t�old� TOWN OF SOUTHOLD -(®V'0;A69all Annex- 54375 Main Road - PO Box 1179 o:. Southold, New York 11971-0959 ,gaOt Telephone (631) 765-1802 - FAX (631) 765-9502 jamesh(c-southoldtownny.gov — seanda-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 1/8/2025 Company Name: prime electric Electrician's Name: mike hunter License No.: me-52402 Elec. email: mike@primeli.biz Elec. Phone No: 6313875650 p I request an email copy of Certificate of Compliance Elec. Address.: 1380 broadway ave holbrook ny 11741 JOB SITE INFORMATION (All Information Required) Name: gem hunter property solutions Address: 3420rocky point rd east marion Cross Street: main rd Phone No.: 6313875650 Bldg.Permit#: 51019 email: mike@primeli.biz Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): pool inspection 100amp pool panel with 4 pool lights, 1 pump,electric heater, 1 transfomer,and service gfi,water bond on pool piping Square Footage: Circle All That Apply: Is job ready for inspection?: YES ❑ NO ❑Rough in ® Final RV Do you need a Temp Certificate?: ❑ YES ❑� NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service[—]Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame D Pole Work done on Service? DY MN Additional Information: PAYMENT DUE WITH APPLICATION ' 2S f PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. W/D Panel Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV Inst Hot DeHum Transfer HOT TUB/SPA Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments 5upvfy PPOPEPT J 0 SHUA R. WICKS P . L . S SOUTHERN BOULEVARD O 51�1A SURVEYED BY:1.R.W. DRAWN BY:J.R.W. JOB NO.:JRWz4-Oo76 ® 1-� ULE V A RD M51-MA00N, TOWN OF 50UTHO�d P.O. BOX 593 — 5UFFOLK COUNTY NSW YO?K Center Moriches, N.Y. 11934 JoshuaRWicks@gmail.com �c, v� #631-405-8108 6 Suffolk County 1 ax Map No,; 05,E 's GRAPHICSCALE (20) (40) Lw PATF 5UPVMP: 0-1/06/2024 (2) SCALD: 1' =20' cd Ir ao N 88049 '00" E 212. 59 ' TAX LOT 7 , 6' STOCKADE FE. MON. FND. 00 O � o WOOD CONC. STEPS AC I PLAT 0, TANK S 1 s 21.6PROP• 0O4.T ' ' Co i C/E/ 6.5 OVERHEAD WIRES Y. AK-) BARN �1 N FR. u? O R3s—OH OH --OH OH. -OH --'OH OH ;m FR. RES. woos i C , ! / ( �, �, N #3420 18'HIGH ENCL. �' In �10 0' f�, PORCH ( � j 0 ' CONC. �f/fr15.0 tj 15.5'— o �- `� LOT AREA v METAL 0 00VER 19,068.00 S:F. in in O �' 4 0.44 ACRE(S) ASPHALT DRIVEWAY N cli Lt�" 1 WOOD REL WALL(8' 6.' PVC FE. 4' CHAIN LINK FE. QF NEW 1 4' WIRE FE. — — — — — 6' STOCKADE FE. R. TAX LOT 14.3 4 S 85050 '40" W 211. 27' l��F N0. 05102� ysF� LAND. CHECKED BY: (1) UNAUTHORIZED ALTERATION OR ADDITION 7O THIS SURVEY MAP BEARING A LICENSED LAND SURVEYOR'S SEAL IS A VIOLATION OF SECTION 7209. SUB-DIVISION 2. OF NEW YORK STATE EDUCATION LAW. (2) ONLY BOUNDARY SURVEY MAPS WITH THE SURVEYOR'S EMBOSSED SEAL ARE GENUINE TRUE AND CORRECT COPIES OF THE SURVEYOR'S ORIGINAL WORK AN ICERTIFICATIONSD OGEN Y. AN E ON THIS BOUNDARY SURVEY MAP W SIGNIFY THAT THE MAP WAS PREPARED IN ACCORDANCE WITH THE CURRENT EXISTING CODE OF PRACTICE FOR LAND SURVEYS ADOPTED BY THE NEW YORK STATE ASSOCIATION OF PROFESSIONAL LAND SURVEYORS, INC. THE CERTIFICATION IS LIMBED TO PERSONS FOR WHOM THE BOUNDARY SURVEY MAP IS PREPARED, TO THE.TREE COMPANY, TO THE GOVERNMENTAL AGENCY AN T F- BOUNDARY SURVEY MAP. (4) THE CERTIFICATIONS HEREIN ARE NOT TRANSFERABLE. (5) THE LOCATION OF UNDERGROUND IMPROVEMENTS OR ENCROACHMENTS ARE NOT ALWAYS KNOWN AND OFTEN MUST BE ESTIMATED. IF ANY UNDERGROUND IMPROVEMENTS OR ENCROACHMENTS EXIST OR ARE SHOWN, THE IMPROVEMENTS OR ENCROACHMENTS ARE NOT COVERED Y THIS D 0 THE LENDING (ORINS DIMENSIONS) LISTED O THIS B HI_ SURVEY. (6) THE OFFSET ED DIMENSIONS} SHOWN HEREON O FROM THE STRUCTURES E THE PROPERTY LINES ARE FOR A SPECIFIC PURPOSE AND USE AND THEREFORE ARE NOT INTENDED TO GUIDE THE ERECTION OF FENCES, RETAINING WALLS, POOLS, PATIOS PLANTING AREAS, ADDITIONS TO BUILDINGS, AND ANY OTHEP, TYPE OF CONSTRUCTION. (7) PROPERTY CORNER MONUMENTS WERE NOT SET AS PART OF THIS SURVEY, (g) iH15 SURVEY WAS PERFORMED WITH A iRi,MBLE 55 ROBOTIC TOTAL STATION. (9) THE EXISTENCE OF RIGHT OF WAYS AND/OR EASEMENTS OF RECORD IF ANY, NOT SHOWN ARE NOT GUARANTEED. � I 9&vf_eL APPROVED AS NOTED OCCUPANCY OR DATE B.Ft# USE IS UNLAWFUL FEE BY. WITHOUT CERTIFICATE NOTIFY 6311-7 5-11 802DING 8AMDEPARTMENTAT T0 PM FOR THE OF OCCUPANCY FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. rt: .jGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. CWPLY V ALL CODES OF ALL CONSTRUCTION SHALL MEET THE ., REQUIREMENTS OF THE CODES OF NEW NEW YORK STATE&TOWN CODES YORK STATE. NOT RESPONSIBLE FOR AS REQUIRED AND CONDITIONS OF DESIGN OR CONSTRUCTON ERRORS MMTMZM 601lt110iC TOWN PIANNWG BOARD SOUm TOWN TRUSTEES N.Y.S.DEC TELY IDHFc EN LbS 'POOL TQsC6DE�- wo 'UPON COMPLETION.-,l- BEFORE"WATER" ` IETAIN STORM WATER RU;�;,; . 'URSUANT TO CHAPTER 236 JF THE TOWN CODE El EC REQUIRE( t COMPLIES WITH 2020 CODE SECTION 303.2.1-303.4 SWIMMING POOLS, SPAS, AND HOT TUBS SECTION R326 OF THE RESIDENTIAL CODE OF NEW YORK SECTION 310D OF THE BUILDING CODE OF NEW YORK SECTION N1103.12 (R403.12) RESIDENTIAL POOLS AND RETURN PERMANENT RESIDENTIAL SPAS SECTION 3109.3.1.2 - 3109.7.4 POOLS AND SPA GATES, BARRIERS SECTION G106 ENTRAPMENT PROTECTION SECTION G107 ALARMS WALKING LEDGE SECTION E4201 - E4312 ELECTRICAL CONNECTIONS FOR POOLS POOL NOTES 1. POCL AND PROPERTY TO CONFORM TO CURRENT STATE AND LOCAL CODE, ENERGY CONSERVATION I R403.10) AND ELECTRICAL CODES. 2. POCL SHALL CONFORM TO ANSI / NSPI STANDARDS R326.3.1 SUN D':CK MA N DR IN d 3. SECTION R326.7 POOL ALARMS TO BE INSTALLED AS REQUIRED BY CODE. Mir 4. INSTALL TEMPOARY PERIMETER BARRIERS AROUND CONSTRICTION AREA 3'A: ART DJRING CONSTRUCTION. FINAL FENCING BARRIER PER P.326.5. ALL GATE ACCESS TO BE SELF-CLOSING AND SELF LATCHING / LOCKING PER CODE. HEAT I R 5. 3500 PSI POURED CONCRETE WALLS, MIN. 40" 6. FINE VASHED SAND BASE WITH PORTLAND MIX AT BC)—IrCiJA PUM 7. SOIL CONDIUDJS AND SITE MANAGEMENT TO BE RESPONSIBILITY OF CONTRACTOR. PROVIDE SOIL TEST IN POOR SOIL CONDITIONS. FILT R 8. SEE SITE PLAN (BY CONTRACTOR) FOR POOL LOCATION. SETBACKS, VARIANCES, AND OTHER STATE AND LOCAL REQUIREMENTS TO BE VERIFIED PRIOR TO -- CONSTRUCTION. 9. DRAIN COVERS TO MEET CODE REQUIREMENTS IVIA. 10. POOL PATIO SURFACE TO SLOPE AWAY FROvI POOL 1/4"=1'-O" AN AWAY FROMHOUSE IF CONNECTED. PROVIDE ADDITIONAL DRAINAGE IF NECESSARY. 11. INSTALL CLEAN BACKFILL, FREE OF CLAY AND O?GANIC MATTER. COVPACT SUCTION SOIL AS REOJIRED PRIOR TO PATIO INSTALLATION. 12. SUCTION CUTLETS PER ANSI / APSP-7. VERIFY IN FIELD PRIOR TO CONSTRUCTION. 36 13. SURCHARGE NOT PERMITTED WITHIN 4' FROM SHALLOW AND 6' FROM DEEP ENDS. 14. DIVING BOARD TO BE DETERMINED BY INSTALLER AND OWNER. T 18. POCL EQUIPMENT LOCATION TO BE DETERMINED IN FIELD M41NTAIN MINIMUM rf) SETBACKS AS REQUIRED). O VINYL LINER TRACK twk 13 REBAR 2""TO VASTE �----- l4)FCRIZCNiAL 6' X 9'CRYWELL HEATERFILTER 19' 8' 6' 3' PimpiSKIMMER 63 REBAR l41 VERTICAL 0 1/4- 39 POOFENTAIR AUTOMATION, LED LIGHTS,FILTRATION.140k ELECTRIC HEATER1 - PAfL-------✓CpBACK TO pT ;D�� OPOOL CPTIClN4L��NAIN diPIN3500 F51 JCONCRETE 7ft . s The Pool Man LOLLWITH TOHYDR TUBE C VALVE AND Cd-.IFCTOR TUBE IN GRAb£L 445E Q PIPING SCHEMATIC N �10. � z WALL DETAIL NOT TO SCALE A Oj?� 2 � POOL TYPE 14x36 Reclargle REV. SCALE N.T.S. NOT TO SCALE �O SSiGO 3420 Rocky Point Rd DATE 3 7 23 East Marion,NY DRAWInG NUMBER °v 1 OF 2 3 NOTES: 1. DIVING BOARD TO CONFORM WITH ANSI/APSP/ICC-5 SEC 6 2. NO SOIL DISCHARGE PERMITTED WITHIN 4 FEET OF EXCAVATION 3. POOL MUST BE SURROUNDED BY A CONTINUOUS BARRIER CONSTRUCTED IAW REQ.OF SEC 326.4.2.1-R326.4.2.6 OF THE NYS RESIDENTIAL CODE(2020)AND ALL SECTIONS OF THE BROOKHAVEN CODE 4. WALLS MAY SERVE AS PART OF THE POOL BARRIER AS PER SEC 326.4.2.8 AND ALL WINDOWS HAVE A SELF LATCHING DEVICE 5. ACESS GATES SHALL COMPLY WITH SEC R326.5.2 OF THE NYS RESIDENTIAL CODE(2020)AND BE SELF CLOSING,SELF LATCHING AND BE SECURELY LOCKED WHEN POOL IS NOT IN USE OR SUPERVISED. ALLL GATES ARE TO OPEN AWAY FROM THE POOL AREA. - 6. DURING CONSTRUCTION THE CONTRACTOR SHALL ERECT A TEMPORARY BARRIER AROUND THE EXCAVATION IAW CODE OF THE TOWN OF BROOKHAVEN. 7. POOL MUST BE EQUIPED WITH AN APPROVED POOL ALARM CAPABLE OF DETECTING ENTRY INTO THE WATER AND SOUNDING AN AUDIBLE ALARM WHEN DETECTED THAT IS AUDIBLE AT THE POOLSIDE AND INSIDE THE DWELLING.THE ALARM MUST BE INSTALLED,MAINTAINED AND USED IN ACCORDANCE WITH TEH MAUFACTURERS INSTRUCTIONS.THE ALARM MUST MEET ASTM F2208"STANDARD SPECIFICATION FOR POOL ALARMS".THE DEVICE MUST OPERATE INDEPENDENT(NOT ATTACHED TO OR DEPENDENT ON)OF PERSONS. 8. POOL SUCTION FITTINGS(EXCEPT FOR SURFACE SKIIMERS)MUST BE PROVIDED WITH A COVER THAT CONFORMS TO ASME/ANSI Al12.19.8M OR A MINIMUM 18"X23"DRAIN GRATE OR A CHANNEL DRAIN SYSTEM.POOL CIRCULATION SYSTEM MUST BE EQUIPTED WITH ATMOSPHERIC VACUUM RELEIF.SUCH VACUUM RELIEF SYSTEMS SHALL CONFORM WITH ASME A112.19.17 OR BE A GRAVITY SYSTEM APPROVED BY THE TOWN OF BROOKHAVEN.POOL SALL BE PROVIDED WITH A MINIMUM OF 2 SUCTION FITTINGS OF THE ABOVE MENTIONED TYPE.THE SUCTION FITTINGS SHALL BE SEPARATED BY A MINIMUM OF 3'AND MUST BE PIPED SUCH THAT WATER IS DRAWN THROUGH THEM SIMULTANEOUSLY THROUGH A VACUUM RELIEF-PROTECTED LINE TO THE PUMP(OR PUMPS).VACUUM/PRESSURE CLEANING FITTINGS SHALL BE IN ACCESSIBLE POSITION,MINIMUM OF 6"AND NO GREATER THAN 12"BELOW THE MINIMUM OPERATIONAL WATER LEVEL OR BE AN ATTACHMENT TO THE SKIMMER/SKIMMERS. A REQUIRED POOL ATMOSPHERIC VACUUM RELEIF SYSTEM SHALL BE INSTALLED AS PER NYS RESIDENTIAL CODE R326.6.3(2020)AND IN ACCORDANCE TO TOW CODE 9. ALL ELECTRICAL WORK SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 70(NEC),PRINCIPALLY ARTICLE 680 AND THE NYS RESIDENTIAL CODE SECTION 4102 THROUGH 4106.ALL ELECTRICAL DEVICES MUST BE APPROVED BY UNDERWRITERS LABORATORIES AND BE PROTECTED BY A GOUND FAULT CURRENT INTERRUPER(GFCI).CURRENT CARRYING ELECTRICAL CONDUCTORS EXCEPT FOR THOSE PROVIDING POWER TO POOL LIGHTING AND POOL EQUIPMENT SHALL MEET THE SEPARATION REQUIREMENTS OF TABLE E4203.5. ALL METAL ENCLOSURES;FENCES OR RAILINGS NEAR OR ADJACENT TO THE SWIMMING POOL THAT MAY BECOME ELECTRICALLY CHARGED DUE TO CONTACT WITH AN ELECTRICAL CIRCUIT SHALL BE EFFECTIVELY GROUNDED. 10. WATER SOURCE FILLING THE POOL SHALL BE EQUIPPPED WITH A BACKFLOW PROTECTION DEVICE IAW NYS PLUMBING CODE 608. 11. ALL PIPING IS DIAGRAMMATIC UNLESS OTHERWISE STATED. 12. WALKS, IF PROVIDED SHALL BE NONSLIP AND SLOPE AWAY FROM THE POOL EDGE. 13. A MEANS OF EGRESS FROM DEEP AND SHALLOW ENDS MUST BE PROVIDED IAW ANSI/NSPI-5 SECTION 6. 14. CONTRACTOR TO PLACE THE POOL IAW TOWN OF BROOKHAVEN CODE SETBACKS. 15. ALL DRAINAGE FROM THE POOL SHALL BE MAINTAINED ON THE SUBJECT PROPERTY. 16 THE DESIGN IS BASED ON A DRAINAGE SOIL WITH<10%SILT.GROUND WATER SHALL NOT EXIST WITHIN THE EXCAVATION.IF GROUND WATER EXISTS WITHIN 6'0"FROM GRADE,DEWATERING FACILITIES WILL BE REQUIRED. 17 ALL GAS AND OIL WATER HEATERS(IF INSTALLED)FOR THE IN-GROUND SWIMMING POOL SHALL BE NATIONAL APPLIANCE ENERGY CONSERVATION ACT(NAECA)COMPLIANT.POOL HEATERS SHALL BE TESTED IAW ANSI Z21.56 AND SHALL BE INSTALLED IAW MANUFACTURERS SPECIFICATIONS.OIL FIRED POOL HEATERS SHALL BE TESTED IAW UL726.POOL HEATERS SHALL BE LOCATED OR GUARDED TO PROTECT AGAINST ACCIDENTAL CONTACT OF HOT SURFACES BY PERSONS.POOL HEATERS SHALL BE PROVIDED WITH TEMPERATURE AND PRESSURE-RELIEF VALVES.A BYPASS LINE SHALL BE INSTALLED FROM THE INLET TO OUTLET TO ADJUST WATER OE NEGy FLOW THROUGH THE HATER.POOL HEATERS SHALL BE PROVIDED WITH THE FOLLOWING ENERGY CONSERVATION MEASURES: C, 17.1 ALL POOL HEATERS SHALL BE EQUIPPED WITH AN ON-OFF SWITCH MOUNTED FOR EASY ACCESS TO ALLOW SHUTTING OFF THE OPERATION OF THE HEATER WITHOUT ADJUSTING THE THERMOSTAT SETTING AND TO ALLOW �P 5+�UE�R J-O RESTARTING WITHOUT RELIGHTING THE PILOT LIGHT. AT LEAST ONE THERMOSTAL MUST BE PROVIDED FOR EACH HEATING SYSTEM.HEATED SWIMMING POOLS SHALL BE EQUIPTED WITH A POOL COVER.(exempt FROM THIS �t� ,� �- ARE OUTDOOR POOLD)DERIVING 20%OF THE ENERGY FOR HEATING THE POOL FROM RENEWABLE SOURCES OVER AN OPERATING SEASON. r xn ' O m 17.2 TIME CLOCKS SHALL BE INSTALLED SO THE PUMP CAN BE SET TO RUN DURING OFF-PEAK ELECTRICAL DEMAND PERIODS,AND CAN BE SET TO RUN THE MINIMUM TIME NECESSARY TO MAINTAIN THE POOL WATER IN A CLEAN T ,.. AND SANITORY CONDITION IAW APPLCIABLE SANITORY CODE OF NEW YORK STATE. - O 0 2\ 18 BACKFILL WILL BE DONE WITH CLEAN EARTH FREE OF ROOTS AND DEBRIS. BACKFILL HEIGHT AND WATER LEVEL TO BE WITHIN 8"OF EACH OTHER. PLACE CONCRETE ON SANDY LOAM SOIL. CLAY TO BE REMOVED AND �OS510NP� REPLACED WITH SANDY LOAM. 19 THERE IS NO MAIN DRAIN IN THIS POOL. SUCTION FOR THE POOL WATER CICULATION IS PROVIDED BY THE SKIMMERS ONLY. THIS MEETS REQUIREMENTS OF NYS CODE SEC 326.5 FOR ENTRAPMENT PROTECTION 20 THE POOL WAS DESIGNED REFERENCES AS THE FOLLOWING: The Pool Man KLOKEL 20.1 THE RESIDENTIAL BUILDING CODE OF NEW YORK STATE(2020)SEC R326 20.2 THE ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE(2020)SEC R403.10 7 SHAW LANE 20.3 THE FUEL GAS CODE OF NEW YORK STATE(2020) EAST MORICHES NY 20.4 THE NEW YORK STATE SANITORY CODE. 20.5 ANSI/APSP/ICC-5 STANDARD FOR RESIDENTIAL IN-GROUND SWIMMING POOLS. POOL NOTES SCALE: NTS 20.6 BOCA CODE SECTION 421. JAMES DEERKOSKI, P.E. DATE: 411912024 20.7 COMPLIES WITH CODE OF THE TOWN OF BROOKHAVEN SECTION 85-891 260 DEER DRIVE MATTITUK, NEW YORK 11952 DRAWING NUMBER 2 OF 2