Loading...
HomeMy WebLinkAbout52442-Z of Sao ryo`o Town of Southold * * P.O. Box 1179 ,0 53095 Main Rd o`r�oUMTV. Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46953 Date: 04/06/2026 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2450 Peters Neck Rd Orient, NY 11957 S ec/B lock/Lot: 3 2.4-8 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 10/21/2025 Pursuant to which Building Permit No. 52442 and dated: 11/07/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof mounted solar to existing single family dwelling as applied for. The certificate is issued to: Isle of Cedars LLC Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 2025-1165993 12/11/2025 PLUMBERS CERTIFICATION: Auth 'Jed Sign e Of SOUTy��G TOWN OF SOUTHOLD BUILDING DEPARTMENT .�� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52442 Date: 11/07/2025 Permission is hereby granted to: Isle of Cedars LLC PO BOX 455 Orient, NY 11957 To: Install roof mount solar to existing single family dwelling as applied for,with flood permit. Disconnects must be located on the exterior, labeled,and readily accessible. Premises Located at: 2450 Peters Neck Rd, Orient, NY 11957 SCTM#32.-1-8 Pursuant to application dated 10/21/2025 and approved by the Building Inspector. To expire on 11/07/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 CO-RESIDENTIAL $100.00 Flood Permit $150.00 To 350.00 Y Building Inspector //i++�•� 'ILL r 't� �y, X� �'a.:9,.�� / *i xf\ /kk•�� k°'•C�.'�` 2�„ .c L`r 3•` r1 .'a.e Electrical Ins ectors, Inc. 2025-1165993 Southold, Town Of / ti a: `s Inspector: 115 Issue Date: 12/11/2025 ' New York Board of Firs Underwriters 300 East Meadow Avenue Op r East Meadow,NY 11554 :F Office: (516)794-0400(631)650-0200 Website:www.eiiny.com Rs: Mail To: Property Address: Catizone Electrical Contracting,Inc. Sarah L Latham Michael J.Catizone 2450 Peters Neck Road ' 2060 Ocean Avenue Orient NY 11957 :r Ronkonkoma NY 11779 .' License# Michael J.Catizone 36178ME 3=n ELECTRICAL APPROVAL CERTIFICATE Section: Block: Lot: Permit:52442 , ` AREAS LISTED BELOW ARE APPROVED BY Inspection qc `\ AND FOUND TO BE IN COMPLIANCE WITH THE BUILDING CODE OF NYS }, •r` AND CURRENT PROMULGATED NEC s; No visual defects were found for the electrical inspection provided.No obvious unsatisfactory conditions l were found in the areas herein below only. ` Residential Inspection Final Approved 12/10/2025 :� Total System Size—21.5 KW DC-50 Jinko.430 Solar Panels&50 Enphase Inverters.' S?Z �• \\� 4 This electrical inspection and certificate does not take into account any FEMA,NYS and local flood ■ ■ ■ �i�' !` :.z c.. elevation requirements.It is the responsibility of the property owner to determine if flood elevation requirements apply. NYBFU and Ell are not responsible for any Flood Elevation requirements. �■, r >' Therefore this electrical certificate is only for compliance of NYS Electrical and NEC Codes. ■ ''a� tc ■1 •s►% ` / ! 3 ;! Richard M. Bivone Phili i Goehrtng,Jr. ❑ t President Chief Electrical Inspector r This document features a tamper proof Quick Response code which contains the encrypted original data submitted when certificate was issued. ��.$,ri!i,.• � ��' tr .-rfC•�r ��N1p;>> t.ti/,'�{;19iSu� <<i/13�o;,S•�j�r' `hi1,!Y1:�(.>!:,C+'7.. �t�irr.Ubi��� _..oS;►,�►. F ➢. ELECTRICAL INSPEC'I'OIZS, INC. is nat responsiblc for the existing conditions located at the subject premises. r �1� 1 4Y� t t o➢tS, i Ne .is not r(:sponsible for corrections, Upgrading or replacement of existing �fr F+F �.1 .. - 's;) I� e16&i'tcal vfolatiuh 'PtTli sd �ct premises. Ali), corrective work shall be solely the responsibility of the property ov*-ier �l�iUTY- ,yz D (."FORS, INC. ➢)OF S NOT WARRANTY OR UNDERWRITE THE ELV" tcIC L ar, IF". iOrSA'I'TIIF: IR11,MISF'S. 3. ELECTRICAL INS➢EIC OF,R,•;, urgU- only recogr,iv.es the National Electric Code, the Building Codes of New York Slate all volumes and f.ocaal IM Lill ici;r;l C'.odcs. as Authorized by The Department of State Codes Division,via Villa'-e,To%vn or Pity i�o�ird fZesoiution. 4. AN ELECTRICAL SURVEY consists ofa visual examination ol'the premises ONLY: Electrical Inspectors Inc. will comply with the requirements oINF('F.73, late.,,( edition Chapter I, Section 1-1, 1-2. Ifviolations exist,a Notice ot'Violation(NOV)will be issuccd requiring corrections by a licensed electrical contractor. After the violation has been corrected,a re-inspection,vifl he conducted and il';rppro:-cd zr certilicate shall be issued. 5. AN ELECTRICAL CLf1SE'D WALL iN` ➢IEC`I'ION consists oha visual examination of the area requested ONLY: Electrical Inspectors In,-'. VVill conIplyWith the rcquirenrents ofNFPA 73, latest edition Chapter 1, Section 1-1, 1-2. If violations exist. a Notice ol'Violation (NOV)will he issued requiring corrections by a licensed electrical contractor. After the violation ilars hccll corrected.a rc-inspection will he conducted and if approved a certificate shall be issued. 6. A SURVEY CF:R'➢ 1FWAJ,E does not examine the actual wiring or devices unless all walls are opened and wires and devices are exposed prior to the snr�c� bcin conducted. 7. A CERTIFICATE i> non-tr.ursl;_rai�lr. 8. AN ELECTRICAL INS?i"° .'`I'➢,,N cods;.!!s of'mi examination of wiring and installations during the rough stages of construction. ,A tier compiction oS•thc conshuction a final inspection will he conducted at which tune a certificate will he issued provided no v iolttlion exists. In the even( ;.in inspection is not requested during the rough stages ofconstruction FLECTIIIR AE, iNSIaa:CTORS, INC. will perform a CLOSED WALL SURVEY that consists olfa visual inspection ol'the %Ndrimg and installations only. Since access is limited, F,LECTRICAL INSPECTORS, INC.shall bear no responsibility for�uiy detects or violations at the premises. 9. ELECTRICAL,INSI'E ,"I'011S, ~hall nut be responsible to remove any walls in order to conduct an electrical inspection. 10. ELECTRICAL INSPECTCWS, INS:'. will only release information, certificates and reports to the applicant after payment forserviccs renderM have hcc.n paid in toil. 11. ELECTRICAL INSPECTQIZ;�, ➢l- . assumes no liability for the results ofits inspections. 12. The agreement may not be c:hangcd w-ally 13.The New York Board of i,it- lritlt'.at°,i;crs, 9Lv'- is a scihsidiary of Electrical Inspectors, Inc. It is fully operational and I'unctional and perfurms ciccrrical iitslicctions as it always has. 14.The New York Board of Fire tl, r.'c: ,r:1t>¢s, Lllc and Eleciric:al Inspectors, Inc. inspects properties for compliance with the Building C ocic of lire; tame of`New York, counties and local electrical codes, as well as the promulgated NEC (National Code). OF S0 `f # TOWN OF SOUTHOLD BUILDING DEPT. coum, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL 5'014,e— [ ] .FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Dk, C o DATE 'G INSPECTOR �� k °Michael E. Miele PE Licensed Professional Engineer Licensed In New York, New Jersey, Connecticut & Calif omia New York License#079676 New Jersey License#44042 Connecticut License#23158 California License#31508 December 15, 2025 Town of Southold Building Department The Office of the Building Inspector 54375 NY-25 Southold, NY 11971 Re: Isle of Cedar LLC—2450 Peters Neck Road, Orient, NY 11957 Single Family Residence, Solar Panel Installation Certification Town of Southold, County of Suffolk, State of New York Dear Building Department, I have reviewed the solar energy system installation at the subject address.The system has been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets all building code requirements and is certified as for all code and approved plans for the Town of Southold. I completed my final inspection on December 13, 2025 and I can hereby certify that the installation complies with the 2020 New York State Residential Building Code and all applicable codes and design loads as referenced on the approved plans, including ASCE 7-16 (Minimum Design Loads and Associated Criteria for Buildings and Other Structures). If you have any questions, please feel free to call me at any time. Thanks, in advance. Sincerely Yours, yOF,NSy\ p,\ b , MAR 3 � 9� *� � r�� LU Michael E. Miele, PE 079676/ �'�9OFESSION�� 705 Orrs Mills Road, New Windsor, NY 12553 ♦ Phone 845.629.9693 ♦ NYPSengineer@gmail.com FIELD INSPECTION REPORT DATE COMMENTS t� FOUNDATION (1ST) — — ------------------------------------ FOUNDATION (2ND) �1" o �un ROUGH FRAMING& �o PLUMBING ' � 1 (O INSULATION PER N.Y. STATE ENERGY CODE _ C9 22 FINAL K ADDITIONAL COMMENTS 1 J Z rn X �o � O x r� b �syf° o TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 • o� Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtoM=.pov col:: ya,r Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only E PERMIT NO. Jo� Building Inspector: 0 CT 2 1 2025 Applications`and forms,mast lbe filled out in their entirety:dncomplete „applications,will not be.accepteW tt 'heowner,an l zl-Ing Owner's Authorization for (Page 2)shall,bwcompleted. c, Date: q S 2 -OWNER(S).'OF'PROPERTY. i Name SCTM#1000- o Physical Address: Phone#: Email: Mailing Address CONTACT PERSON Name:Permit Dept./Lon mIsland Power Solutions Mailing Address:2060 Ocean Ave., Ronkonkoma, NY 11779 Phone# 631-348-0001 Email:Permits@GoPowerSolutions.com DESIGN PROFESSIONAL:'INFORMATION. " Name � — _...� Mailing Address Phone#: Email: - ' _ crt ._� �..._�._ nN r ma A� _cam CONTRACTOR INFORMATION:' Name:Michael.Catizone/Long Island=Power Solutions Mailing Address:2060.Ocean Ave.,"Ronkonkoma,.NY 11779 Phone#:631-348 0001 _. rym uEmaillmike GoPowerSolutions com _ DESCRIPTION OF-PROPOSED C ONSTRIICTION ❑New Structure ❑Addition BAlteration ❑Repair ❑Demolition Estimated Cost of Project: ROther Proposed panel roof mounted array. (9-1.Wkw System $ f iagmin Will the lot be re-graded? ❑Yes BNo Will excess fill be removed from premises? ❑Yes @No 1 PROPERTYJNFORMATIOk,� Existing use of property:Sin le Mil Dwellin Intended use of property:Sincile Family Dwellin Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes BNo IF YES, PROVIDE A COPY. hectic Box Af,er Reading:-The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by. Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance ofthe TOwn Of Southold,Suffolk,County,New YorVand other applicable Laws,ordinances or Regulations,for the construction of buildings, additions;alterations or for removal or.demolition,as herein„described.The applimpt�agrees to comply with all applicable laws,'ordinances;building code, g . g P -housing code'and regulations admit authorized ins ectors on premises and iri buildings)for`necessary inspections.False•statements'made herein are punishable as a Class misdemeanor.pursuant to'Section 210.45 of the New York State Penal Law:.':' Catizone Electrical/Long Island Power Solutions Application Submitted By(p nt a BAuthorized Agent ❑Owner _.. _... .._., d ��-..,..... . ..M.-... _ .. .... ...... . ........... .....� _..._._.._ Signature of Applican', Date: STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Michael Catizone being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of LA —hpi ,20� C'L-1 Notary Public r ESCAYLIN CRISOL RIVERA RODRIGUEZ NOTARY PUBLIC-STATE OF NEW YOR'PROPERTY OWNER AUTHORIZATION No. 01 RI6434031 Qualified in Suffolk County (Where the applicant is not the owner) MY Commission Expires 05-31-2026 residing at 24,,5() i �S WcL ecmd owie-A� NV 05-7 do hereby authorize Michael Catizone/Long Island Power Solutions to apply on my behalf to the Town of Southold Building Department for approval as described herein. SCNA aj--, a - Z S-Z� Owner's Signature Date 2NeA)'V ` INN GL_Uyn Print Owner's Name 2 LONG ISLAND ER2060 Ocean Ave Ronkonkoma, NY 11779 PSCOLUTIQNS 631348-0001 wwuv.longislandpowersolutions.eom Chief Operating Authorization Date: Qbr1M2S'---'- To Whom it may concern, Please be advised that �b&c- has authority to sign official documents on behalf of, LE CN C-4?D.jN1 �--�� As sv1� (Title) �kSignature: t-- u-/l� ZS Sworn to,before me-this �" day of ,202 NECOLE GIORGETTI E OF NEW YORK NOTARY PUBLIC,STAT N0. 01 G10004569 Notar igriat QUALIFIED IN SUFFOLK COUNTY MY GOMMISSION EXPIRES MAR 30,2027 Go Green,Save Green LONG ISLAND OWER 2060 Ocean Ave Ronkonkoma, NY 11779 631 348-0001 SOLUTIONS www.longislandpowersolutions.com OWNER AUTHORIZATION This affidavit certifies that Long Island Power Solutions has been granted permission to sign for and obtain permit(s)on behalf of the pro erty owner(s). I, ,Owner of the property located at: 2� c� R-e- ---, Kk&JL QI nnrc-k L 1 J9s1 Street Town S Zip Tax Map ID#: SO. --L- R . Do hereby give: Long Island Power Solutions uermission to sign all applications and to have the permit(s) sent directly to: Long Island Power Solutions 2060 Ocean Avenue Ronkonkoma,NY 11779 Attn:P t Dept. It"ON4 kmg-(AA (Property Owner) Name (Property Owner) Signature Sworn To Before Me This ZS Day Of 2sipf;20 , NICOLE GIORGETTI (NOTARY UBLIC SI RE) fM NOTARY PUBLIC,STATE OF NEW YORK NO. 01 G10004569 QUALIFIED IN SUFFOLK COUNTY MY COMMISSION EXPIRES MAR 30,2027 . fry Notary Stamp G® Green Save Green S�fFOi '' moo �o� TOVTN ?:F,SOUTHOLD—BUILDING DEPARTMENT ro :fig Town Hall Annexi54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 oy • o f Telephoned( 31) 765-1802 https://www.southoldtowM.jzov N 0 V 1 3 P025 ._Flo,o,d,pj,@in Development Permit Application PROPERTY INFORMATION: Flood Zone: FIRM Panel: SCTM#1000-3,p,-J_ -� Address: b > r•,en+ 0 `� City: -�- Zip: �v CONTACT PERSON: Name: Phone#:�yl-3y pL r Mailing Address:aySo n6eC N SS-1 PROJECT DESCRIPTION: q CaG SECTION A:STRUCTURAL DEVELOPMENT(CHECK ALL THAT APPLY) Type of Structure Type of Structural Activity Residential(1 to 4 families) ❑New structure ❑ Residential(more than 4 families) ❑Demolition of existing structure ❑ Combined use ❑ Replacement of existing structure ❑Non-residential ❑ Relocation of existing structure ❑ Elevated ❑ Addition to existing structure ❑ Flood proofed(attach certification) ❑ Alteration to existing structure ❑Manufactured Home ❑ Other: _�o, ❑Located on individual lot ❑ Located in manufactured home park SECTION B: OTHER DEVELOPMENT(CHECK ALL THAT APPLY) ❑ Clearing of trees,vegetation or debris ❑ Mining ❑ Grading ❑ Drilling ❑ Dredging ❑ Connection to public utilities or services ❑ Paving ❑ Placement of fill material ❑ Drainage improvement(including culvert work) ❑ Roadway or bridge construction ❑ Fence or wall construction ❑Watercourse alteration (attach description) ❑ Excavation (not related to a structured development) ❑ Other development not listed (specify): By signing below I agree to the terms and conditions of this permit and certify to the best of my knowledge the information contained in this application is true and accurate. I understand that no work may start until a permit is issued.The permit may be revoked if any false statements are made herein. If revoked,all work must cease until permit is re-issued. Development shall not be used or occupied until a Cert.of Compliance is issued.The permit will expire if no work is commenced within one year of issuance.Other permits may be required to fulfill regulatory requirements.Applicant gives consent to local authority or representative to make reasonable inspections to verify compliance. Application Submitted By(print name): �`�G�lo►e� c ' -a�2at12 -1�f ra, f"� ��rr1 S Ge.d� `. Signature of Applicant: Date: V U I A A�t� Zk BUILDING DEPARTMENT- Electrical Inspector ' TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold; New York 11971-0959 a .,`•�' Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr a-southoldtownn�gov -.sea.nd0southoldtownny -gov APPLICATION FOR ELECTRICAL INSPECTION. ELECTRICIAN INFORMATION (All Information Required) Date; Company Name: Catizone Electrical/Long Island Power Solutions Name: Michael Catizone License No.: -�5� email: Permits@GoPowerSolutions.com - _ Add ress: 2060 Ocean Avenue,Ronkonkoma,NY 11779 Phone No.: 631-348-0001 JOB SITE INFORMATION (All Information Required) Name: fa,r_� le _ Z'L Address: �'�5C5 Cross Street: �-��. _. al Phone No.: - Bldg.Permit#: email: Q Tax Map Distract: 1000 Section: 30LBlock: - Lot: BRIEF DESCRIPTION OF WORK (Please Print Clearly) Proposed(:So )panel roof mounted array. (,9/,So )kW System Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On. Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: _ _ __A #Meters _ __ _- Old Meter# New Service- Fire Reconnect- Flood Reconnect- Service Reconnected- Underground -Overhead Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: /cr. /k.�►'I�3�s�! .PAYMENT_D-UE WITH.APPLICATION Request for Inspection Formals LONG ISLAND OWER 2060 Ocean Ave Ronkonkoma, NY 11779 FS(OLUTIONS 631 348-0001 www.longislandpowersolutions.com TOWN OF SOUTHOLD—Building Division Town Hall Annex Building 54375 Route 25 P.O. Box 1179 Southold,NY 11971 Dear Building Dept: As per your Building Department, enclosed please find the building permit application, submitted on behalf of our client/property owner: Property Owner: Sarah Anglum for Isle Of cedars LLC- 631-335-6688 Project/Property Address: 2450 Peters Neck Road Orient NY 11957 Section/Block/Lot: 1000-3 2.-1-8 Electrician Michael Catizone—2060 Ocean Ave.,Ronkonkoma,NY 11779—(631)348-0001 Contractor LI Power Solutions—2060 Ocean Ave.,Ronkonkoma,NY 11779—(631)348-0001 Architecture&Planning: Michael E.Miele-PE-33 Quaker Avenue,Po Box 530, Cornwall NY 12518- 845-629- 9693 Enclosed Please find: • Application Fee: $200.00 • Permit Application • (4) Copies of the Property Survey • (4) Copies of the Engineering Drawings& Specs • Liability, Disability & Workman's Comp Insurance Certs Please send the Receipt and Permit to Long Island Power Solutions. Should you require anything further, please contact me. Sincerely, Escaylin Rivera Permit Manager Long Island Power Solutions 2060 Ocean Avenue Ronkonkoma,NY 11779 Ph- 631-348-0001 Fx- 631-348-0018 Permits@gopowerosolutions.com Go Green Save Green Michael E. Miele, PE Licensed Professional Engineer Licensed In New York, New Jersey, Connecticut&California New York License#079676 New Jersey License#44042 Connecticut License#23158 California License#31508 October 14,2025 Town of Southold Building Department The Office of the Building Inspector 54375 NY-25 Southold, NY 11971 Re: Isle of Cedars LLC—2450 Peters Neck Road, Orient, NY 11957 Single Family Residence,Solar Panel Loading Certification Town of Southold. County of Suffolk,State of New York Dear Building Department I am the engineer of record for the above-referenced project. I have prepared the attached plans dated September 17,2025 that consist of the installation of(50)JKM430N-54HL4-B solar panels at the above referenced location. I can hereby certify that the existing roof structure combined with the additional weight of the solar panels meets the requirements of The 2020 Residential Code of New York State, Publication Date, November 2019. The design loads were as follows, Ground Snow Load:20psf Wind Design Load: 136mph No additional structural members were required. The roof is currently framed with 2x6 true dimensional,2x8 and 2x10 wood framing @ 16"O.C.The roof structural members are in compliance with ASCE 7-16 for deflection and acceptable bending stress. If you have any questions, please feel free to call me at any time.Thanks in advance. P�� OF NEW y Sincerely Yours, C_ EL E. 0�� ILA-7s' �wu Michael E. Miele, PE `P`O 079676 �2 ��OFESSION��' 705 Orrs Mills Road, New Windsor, NY 12553 ♦ Phone:845.629.9693♦ NYPSengineer@gmail.com • CONTRACTOR ` ISLE OF CEDARS LLC C*PO LUTINER ONS AHJ UTILITY SCOPE OF WORK VICINITY MAP LONG ISLAND POWER TOWN OF SOUTHOLD PSEG LONG ISLAND (N)21.50KW DC ROOF MOUNTED PV SYSTEM \ SOLUTIONS (50)JINKO SOLAR JKM430N-54HL4-B MODULES Ra- -- 2060 OCEAN AVENUE, (60) ENPHASE IQ8MC-72-M-US (240V) MICROINVERTERS q' "'`pt twO -- (01) PV DEDICATED SUB PANEL RONKONKOMA, NY 11779 CODES AND STANDARDS WITH AMENDMENTS [. +1 631 348 0001 2020 BCNYS 2020 FCNYS ' PROJECT INFO&ADDRESS 2020 RCNYS 2450 Peters,Neck 2017 NEC Rd,rime,NY Sta1 s957, ISLE OF CEDARS LLC United2450 PETERS NECK RD, ENVIRONMENTAL "�- ORIENT, WIND SPEED: 136 MPH NY 11957 SNOW LOAD: 20 PSF L ��. EXPOSURE CATEGORY: B SYSTEM SIZE DC SIZE:21.500 KW DC-(STC) GENERAL NOTES NOTE: - TO THE BEST OF MY KNOWLEDGE, PROJECT NOTES: SHEET INDEX JBU GEMENTPTHEPLANSAND -THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH ACCT NO: 9682014302 PV-1 COVER SHEET SPECIFICATIONS ARE 2020 THE NATIONAL ELECTRIC CODE (NEC)ARTICLE 690,ALL COMPLIANCE WITH THE PV-2 SITE PLAN-1 RESIDENTIAL CODE OF NEWEWYORK MANUFACTURER'S LISTING AND INSTALLATION STATE. INSTRUCTIONS,AND THE RELEVANT CODES AS SPECIFIED PSEG Account# 9682014302 PV-2.1 SITE PLAN-2 - IT IS A VIOLATION OF THE LAW FOR PV-3 ATTACHMENT PLAN ANY PERSON,UNLESS ACTING BY THE AUTHORITY HAVING JURISDICTION'S (AHJ) PV-3.1 STRUCTURAL PLAN UNDER THE DIRECTION OF APPLICABLE CODES. PV-4 ELECTRICAL LICENSED PROFESSIONAL,TO -THE UTILITY INTERCONNECTION APPLICATION MUST BE ALTER AN ITEM IN ANY WAY.IF AN F A APPROVED AND PV SYSTEM INSPECTED PRIOR TO APPROVED AS NOTED _ PV-4.1 ELECTRICAL CALCULATIONS ITEM BEARING THE SEAL L IS �' PV-5 LABELS LICENSED PROFESSIONAL IS PARALLEL OPERATION OCCUPANCY OR d.. ALTERESIONALSHALL AFFIX DATE.�� •a S B.P. 'z PV-6 RESOURCE DOCUMENT PROFESSIONAL SHALL AFFIX TO -GROUND FAULT DETECTION AND INTERRUPTION(GFDI) r`' DEVICE IS INTEGRATED WITH THE MICRO INVERTERS IN PV-6.1 RESOURCE DOCUMENT THEIR ITEM THEIR SEAL AND THE FEE Ja.ST�•�D BY: USE IS -UNLAWFUL PV-6.2 RESOURCE DOCUMENT NOTATION"ALTERED BY" ACCORDANCE WITH NEC 690.41 B FOLLOWED BY THEIR SIGNATURE ( ) AND THE DATE OF SUCH -ALL PV SYSTEM COMPONENTS; MODULES, UTILITY- NOTIFY BUILDING DEPARTMEN AT WITHOUT CERTIFICATE PV-6.3 RESOURCE DOCUMENT 631-765-1802 8AM TO 4PM FOR THE PV-6.4 RESOURCE DOCUMENT ALTERATION,AND A SPECIFIC INTERACTIVE INVERTERS,AND SOURCE CIRCUIT COMBINER OF OCCUPANCY DESCRI ER ION. FOLLOWING INSPECTIONS: "'""' PV-6.5 RESOURCE DOCUMENT BOXES ARE IDENTIFIED AND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4: PV 1, FOUNDATION-TWO REQUIRED PV-6.6 RESOURCE DOCUMENT Q• O FOR POURED CONCRETE PV-6.7 RESOURCE DOCUMENT �� �• � .MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 2 ROUGH-FRAMING&PLUMBING PV-6.8 RESOURCE DOCUMENT � CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 3. INSULATION 929, 519 COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY 4. FINAL-CONSTRUCTION MUST COMPLY WfTH .CODES OF -MAX DC VOLTAGE CALCULATED USING MANUFACTURER BE COMPLETE FOR C.O. NE1N YORK STATE:Bi TOWN CODES mmec f01RRlImmm O 079676 PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, ALL CONSTRUCTION SHALL MEET THE AS REgU�RE .,,ANp CONp1TlONS OF a- MAX DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7. REQUIREMENTS OF THE CODES OF NEW :.£..,„ -ALL INVERTERS, PHOTOVOLTAIC MODULES,PHOTOVOLTAIC YORK STATE. NOT RESPONSIBLE FOR Y . .._ „ TOVYNZBA`' DRAWN BY MP PANELS,AND SOURCE CIRCUIT COMBINERS INTENDED FOR DESIGN OR CONSTRUCTON ERRORS DTOWN_�BON USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE "-` w ern DATE 9/17/2025 IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4. TO !' i RETAIN STORM WATER RUNOFF SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS FLOW + s �� " N.Y.S.DEC PURSUANT TO CHAPTER REVISION FROM LISTING OR LABELING [NEC 110.31. $Q(J�IO(O}� OF PIER 236 SIGNATURE THE TOWN CODE. -ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL COMPLY W #�ei a BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV �.1 � �� ���. ���� �,�-_�,. . $�HQr' PV-1 RESISTANT.ALL PLAQUES AND SIGNAGE WILL BE INSTALLED COVER SHEET AS REQUIRED BY THE NEC AND AHJ. - CONTRACTOR SCOPE OF WORK TOTAL ROOF SQUARE FOOTAGE IS: 3295.93 FTZ (N)21.50KW DC ROOF MOUNTED PV SYSTEM NEW ARRAY SQUARE FOOTAGE IS: 1050.96 FTZ sop (50)JINKO SOLAR JKM430N-54HL4-B MODULES COVERED BY SOLAR IS: 31.89% 4 SOLUTIONS (50) ENPHASE 108MC-72-M-US(240V) MICROINVERTERS (01) PV DEDICATED SUB PANEL PETERS NECK CCK p D LONG ISLAND POWER SOLUTIONS 2060 OCEAN AVENUE, RONKONKOMA, NY 11779 +1 631 348 0001 �-- 96'-911 _04 1001 a� 8►� PROJECT INFO&ADDRESS ISLE OF CEDARS LLC I �< 2450 PETERS NECK RD, ORIENT, NY 11957 I SYSTEM SIZE ,co DC SIZE: 21.500 KW DC-(STC) NOTE: I - TO THE BEST OF MY KNOWLEDGE, - BELIEF AND PROFESSIONAL JUDGEMENT,THE PLANS AND N (o SPECIFICATIONS ARE IN I N COMPLIANCE WITH THE 2020 N RESIDENTIAL CODE OF NEW YORK c I - STATE. IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING I UNDER THE DIRECTION OF A 93'-3" LICENSED PROFESSIONAL,TO 24'-9" ALTER AN ITEM IN ANY WAY.IF AN ITEM BEARING THE SEAL OF A LICENSED PROFESSIONAL IS I ALTERED,THE ALTERING LICENSED PROFESSIONAL SHALL AFFIX TO I (E) NON-HABITABLE THEIR ITEM THEIR SEAL AND THE DETACHED STRUCTURE NOTATION"ALTERED BY" FOLLOWED BY THEIR SIGNATURE AND THE DATE OF SUCH ALTERATION,AND A SPECIFIC I DESC ERATION. (E)MAIN HOUSE •`�,0 1Y�. 912:9„ 2 LEGEND 'y � y FIRE PATHWAYS p 079676 ----- PROPERTY LINE �—FENCE DRAWN BY MP ® SKYLIGHT/CHIMNEY DATE 9/17/2025 O❑ VENT/OBSTRUCTION REVISION SIGNATURE SITE PLANA PV-2 SCALE:1/64"=1'-0" SITE PLAN-1 SCOPE OF WORK CONTRACTOR (N)21.50KW DC ROOF MOUNTED PV SYSTEM /� TOTAL ROOF SQUARE FOOTAGE IS: 3295.93 FTz (50)JINKO SOLAR JKM430N-54HL4-B MODULES PETERS NEW ARRAY SQUARE FOOTAGE IS: 1050.96 FTz WER50 ENPHASE IQ8MC-72-M-US 240V MICROINVERTER NECOVERED BY SOLAR IS: 31.89% CoPO LUTIONS (01) ENPHASE IQ COMBINER 4/4C PANEL S ACCESS ROOF LADDER ACCESS 1 (N)(02)JUNCTION LONG ISLAND POWER SOX NEMA4X RATED SOLUTIONS 2060 OCEAN AVENUE, (N)CONDUIT RUN RONKONKOMA, NY 11779 rr 3-Orr p +1 631 348 0001 (E)MAIN SERVICE PANEL-2 cy) (INSIDE HOUSE) (N)PV DEDICATED SUB PANEL (OUTSIDE HOUSE) PROJECT INFO&ADDRESS $ Isle of Cedars LLC p 3,Orr _ 2450 PETERS NECK RD, p m — — _ ORIENT, �O M NY 11957 I � Q SYSTEM SIZE '00M o �� (N)VISIBLE LOCKABLE LABELED DC SIZE: 21.500 KW DC-(STC) r J.0 AND FUSED AC DISCONNECT r (UTILITY DISCONNECT) NOTE: (OUTSIDE HOUSE) - TO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL (E)ATS PANEL JUDGEMENT,THE PLANS AND (OUTSIDE HOUSE) SPECIFICATIONS ARE IN O O COMPLIANCE WITH THE 2020 / (E) UTILITY METER RESIDENTIAL CODE OF NEW YORK v (UNDERGROUND SERVICE) STATE. p O - IT IS A VIOLATION OF THE LAW FOR (OUTSIDE HOUSE) ANY PERSON,UNLESS ACTING (E)MAIN SERVICE PANEL-1 UNDER THE DIRECTION OF A LICENED PROFESSIONAL,TO r s (INSIDE HOUSE) ALTER AN ITEM IN ANY WAY.IF AN M ITEM BEARING THE SEAL OF A LICENSED PROFESSIONAL IS ALTERED,THE ALTERING LICENSED PROFESSIONAL SHALL AFFIX TO LADDER ACCESS 2 THEIR ITEM THEIR SEAL AND THE NOTATION"ALTERED BY" FOLLOWED BY THEIR SIGNATURE AND THE DATE OF SUCH O ALTERATION SPECIFIC IDESCI I aF T RATION. (N)(50)JINKO SOLAR JKM430N-54HL4-B MODULES WITH ENPHASE r'Orr * <^ y} IQ8MC-72-M-US MICROINVERTERS UNDER EACH MODULE(240V) Lai LEGEND 2 079676 FIRE PATHWAYS PROPERTY LINE -o--FENCE DRAWN BY MP SKYLIGHT/CHIMNEY DATE 9/17/2025 O VENT/OBSTRUCTION REVISION SIGNATURE SITE PLAN-2 PV-2.1 SCALE:3/32" = 1'-0" SITE PLAN-2 ROOF SECTION(S) CONTRACTOR T, 11,�„ 7'-4 O E R ROOF MATERIAL- ROOF MATERIAL- COMPOSITE SHINGLE COMPOSITE SHINGLE [ I 1 I [ [ 1 1 a a 1 1 1 1 [ 1 �' ROOF 1 RAFTER SIZE-2"X8" ROOF 4 RAFTER SIZE-2"X10" 1 1 r I ' I I I 1 1 I I I a i f l i i` f 1 a i I 'i i l t i' s �� I I1, I r 1 1 1 ! l l 101 1 1 r. l [ [ 1 7 1 , I t 1 1 1 1 1 , 1 , l r 1, I I, , I• I 1 1 V O.C.SPACING-16' O.C.SPACING-16' 1 1 1 MODULES-6 MODULES-5r- a f. s a 11 , .[ 1• 1 ! f .1, LONG ISLAND POWER ROOF MATERIAL- ROOF MATERIAL- 1 1 t Til t a i i , e" 1' I I i 1 ,. t i l l 11• 1 41 l COMPOSITE SHINGLE COMPOSITE SHINGLE . . •. : _ SOLUTIONS ROOF2 RAFTER SIZE-2 X6' ROOF 5 RAFTER SIZE-2'X10 2060 OCEAN AVENUE, O.C.SPACING-16" O.C.SPACING-16" , ' r 1 ;. 1 ' , 1 r 1 , 1 1, a I ° ° [ 1. 1. I RONKONKOMA, NY 11779 MODULES-9 MODULES-9 ROOF MATERIAL- ROOF MATERIAL- s" -- •18'-9" 20'-4" +1 631 348 0001 COMPOSITE SHINGLE COMPOSITE SHINGLE ARRAY 1 ARRAY 2 ROOF 3 RAFTER SIZE-2"X6" ROOF 6 RAFTER SIZE-2'X10" O.C.SPACING-16" O.C.SPACING-16" TILT- 32 DEG TILT- 40 DEG MODULES-7 MODULES-14 AZIMUTH - 192 DEG AZIMUTH - 102 DEG PROJECT INFO BADDRESS ISLE OF CEDARS LLC 0 DEAD LOAD CALCULATION 2450 PETERS NECK RD, 1 T 4" 8'4° -- - ORIENT, TOTAL t 1 ! t .1 t 1 ! .i t 1 f r t". t 1 a 1 1 r a I I NY 11957 BOM QUANTITY LBS/UNIT 1 f l t i ! WEIGHT(LBS) [ [ , B •fr• Iltrltll r1 1a a 11Ia fall . I r [ 1 c B:'r ` 1 i l I t _ JINKO SOLAR 50 48.5 2425.00 SYSTEM SIZE t { 1 1 1 [ t DC SIZE 21.500 KW DC- (STC) JKM430N-54HL4-B MODULES MID-CLAMP 64 0.15 9.60 1 1 1 1 1 1 1 1 1 1 r t r t t r" t 1 NOTE: ! ! t I ! I ! tt . t t t r- 1 i t [ .[ II [. [ r 1 "° E 1 .1 I. i i.•1 t 1 1 , ,! - TO THE BEST OF MY KNOWLEDGE, END-CLAMP 72 0.15 10.80 I [ t tt I 1 •I t t P t 1 t E :E r IN'T BELIEF AND PROFESSIONAL JUDGEMENT,THE PLANS AND RAIL LENGTH 48 6.36 305.28SPLICE BAR 12 0.525 6,30SPECIFICATIONS ARE IN -' 19'-T' 17'-°" T-1" COMPLIANCE WITH THE 2020 ARRAY 4 RESIDENTIAL CODE OFNEWYORK IRONRIDGE QUICKMOUNT 131 0.57 74.67 ARRAY 3 STATE. HUG TILT- 32 DEG ANYPERSON,UN UNLESS ACIT IS A VIOLATION OF THE LAW TING TILT- 38 DEG AZIMUTH - 192 DEG UNDER THE DIRECTION OF A ENPHASE IQ8MC-72-M-US 50 2.43 121.50 AZIMUTH - 282 DEG LICENSED PROFESSIONAL,TO MICROINVERTER ALTER AN ITEM IN ANY WAY.IF AN ITEM BEARING THE SEAL OF A LICENSED PROFESSIONAL IS TOTAL WEIGHT OF THE SYSTEM (LBS) 2953.15 I I I r 1 r •I i I r I r I r I 1 1 I 1 'I' I ALTERED,THE ALTERING LICENSED 1. PROFESSIONAL SHALL AFFIX TO TOTAL ARRAY AREA ON THE ROOF SQ.F 1050.96 r 1 1 I t a 'I t I I I 1 I 1. .I r I I i I 1 r. I 1. I t t I "1 I THEIR ITEM THEIR SEAL AND THE ( � r •I' I r' I r l F 'r I I t• i I ;I •I L. IT. I t ,I .I I I I I i I. I 11 1 ARRAY 5 NOTATION"ALTERED BY" WEIGHT PER SQ.FT. LBS 2.31 I I' 1 1: I I I d I d. I I I I i I I 1. FOLLOWED BY THEIR SIGNATURE (LBS) I .I. I I I I. I I I I. f I. I L. "I 11 l 1 L I N 1 I f I t I I I I TILT- 39 DEG AND THE DATE OF SUCH WEIGHT PER PENETRATION (LBS) 22.54 1 1 i 1 I 1 I 1 1 r I 1 t I 1 j I I I I I i I I r- 1 t 1 I 'r. I•. 1 ALTERATION SPECIFIC I I' I 1 AZIMUTH -282 DEG DESMrN f�RATION. r N - f ,I f .I f l l l f",I 1 1 I;... `` I I I f I I 1• ;I 1 I I I I I I I I I I I I I I I' I �• 26'-11" 18'-9" 7 * � — CLAMP — IRONRIDGE QUICKMOUNT HUG — IRONRIDGE AIRE RAIL Al 19 pA 079676 - ------ - RAFTER ► �•. !'-r DRAWN BY MP II 11- :r 1t'.T Itt rr.t rr..r I11 t' I ARRAY6 I, I. 'r I, •' ! •I DATE 9/17/2025 ' i, i TILT— 15 DEG REVISION 131 —TOTAL MOUNT I I I I f 1. 1 t r r 1 t r. I t "r ► t. 1 I B IT 1 I I I, l r"I I' r, AZIMUTH — 102 DEG I. 1 It t t t t t 1 , 1 I . t I t 1 t t I.. SIGNATURE l.. t I. 1 ATTACHMENT PLAN 3'-°" --� 33'-10" 2'-T' PV-3 SCALE:3/32" = V-0" ATTACHMENT PLAN CONTRACTOR CopOWER. LUTIONS LONG ISLAND POWER SOLUTIONS 2060 OCEAN AVENUE, RONKONKOMA, NY 11779 MODULE BOTTOM MOUNTING CLIP +1 631 348 0001 CLAMP w .1" BOLT 4 PROJECT INFO&ADDRESS AND LOCK WASHER ISLE OF CEDARS PLC 2450 PETERS NECK RD, JINKO SOLAR JKM430N-54HL4-B ORIENT, MODULE NY11957 / SYSTEM SIZE RO N R I DG E AI RE RAIL Al / / DC SIZE:21.500 KW DC-(STC) NOTE: 3" BOLT / / - TO THE BEST OF MY KNOWLEDGE, / BELIEF AND PROFESSIONAL / / JUDGEMENT,THE PLANS AND SPECIFICATIONS ARE IN (E) COMPOSITE SHINGLE COMPLIANCE WITH OF NE 0 RESIDENTIAL CODE OF NEW YORK STATE. / - IT IS A VIOLATION OF THE LAW FOR IRONRIDGE QUICKMOUNT HUG UNDER THE DIRECTION OF UNDER THE DIRECTION OF A (2) 5/16" x 3" STAIN LESS LICENSED PROFESSIONAL, .I ALTER AN ITEM IN ANY WAY. F AN ITEM BEARING THE SEAL OF A STEEL SCREWS MIN. 2.5" ALTERED,THE ALT LICENSED HEALT RNALIS ERING LICENSED PROFESSIONAL SHALL AFFIX TO EMBEDMENT THEIR ITEM THEIR SEAL AND THE NOTATION"ALTERED BY" FOLLOWED BY THEIR SIGNATURE AND THE DATE OF SUCH ALTERATION,AND A SPECIFIC DESCR` 0 r 'TERATION. (E) FOR ROOF-1 RAFTER 2"X8' �@ 16" �O.0 �� • �•F�� (E) FOR ROOF-2 & 3 RAFTER 2 X61 @ 16 O.C. (E) FOR ROOF-4, 5 & 6 RAFTER 2"X10" @ 16" O.0 Op 079676 � DRAWN BY MP DATE 9/17/2025 REVISION SIGNATURE 1 1 STRUCTURAL PLAN PV-3.1 SCALE:NTS STRUCTURAL PLAN SOLAR MODULE SPECIFICATIONS NOTE: INVERTER SPECIFICATIONS CONTRACTOR MANUFACTURER/MODEL# JINKO SOLAR JKM430N-54HL4-B ALL CONDUCTORS ARE COPPER UNLESS OTHERWISE NOTED. ENPHASEIQ8MC-72-M-US COWER MODULE MANUFACTURER/MODEL# MICROINVERTER SOLUTIONS VMP 32.58V MIN/MAX DC VOLT RATING 22V MIN/58V MAX IMP 13.20A MAX INPUT POWER 460W VOC 39.16V PSEG Account# 9682014302 NOMINAL AC VOLTAGE RATING 240W211-264V LONG ISLAND POWER ISC 13.65A SOLUTIONS MAX AC CURRENT 1.33A 2060 OCEAN AVENUE, TEMP. COEFF.VOC —0.25%/°C MAX MODULES PER STRING 12(SINGLE PHASE) RONKONKOMA, NY 11779 MODULE DIMENSION 67.79"L x 44.65"W x 1.38"D(In Inch) MAX OUTPUT POWER 320 VA +1 631 348 0001 TO UTILITY GRID (N)(50)JINKO SOLAR JKM430N-54HL4-B 7 N MODULES �oy q PROJECT INFO&ADDRESS (N)(1)AC DISCONNECT: DNE (E)BI-DIRECTIONAL UTILITY (REVENUE ORATE METER( (N)(1)PV DEDICATED SUB VISIBLE,LOCKABLE,LABELED METER 1-PHASE,3-W, ISLE OF CEDARS LLC 10 MICROINVERTERS IN BRANCH CIRCUIT 1 PANEUCOMBINER PANEL, (52,20A/240VAC CIRRCUIT BREAKERS, 100A FUSED,(2)90A FUSES,240V (UNDERGROUND UN RATED NEMA 3R,UL LISTED,125A RATED NEMA 3R,UL LISTED M (UNDERGROUND SERVICE) (3)#12 Q-CABLES (OUTSIDE HOUSE) (UTILITY DISCONNECT) LOAD (OUTSIDE HOUSE) 2450 PETERS NECK RD, ry j i ry j (OUTSIDE HOUSE) SUPPLY SIDE TAP ORIENT, (N)(1)JUNCTION tsnrza N N NY 11957 (E)ATS BREAKER BOX 600V,NEMA 10 MICROINVERTERS IN BRANCH CIRCUIT 2 I — —— — — — — — — — — 240 V.300AI2P SYSTEM SIZE DC SIZE:21.500 KW DC-(STC) zanrz& • • NOTE: I I I I SPER PECIFY MANUFACTURER I (�Ap I — — — — r(E)ATS PANEL, J - TO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL 2aor2P 'fOTA OR 15A OR 20A I (�� ( JUDGEMENT,THE PLANS AND u SPECIFICATIONS ARE IN BREAKER IS I I (E)MAIN BR KER TO I N I LINE SIDE COMPLIANCE WITH THE 2020 SUITABLE FOR USE L— — — HOUSE 240 V,150A/2P INTERCONNECTION RESIDENTIAL CODE OF NEW YORK (BOTTOM FED) — AT ATS PANEL —�— Z0� PER ART.705.12(A) STATE. IT IS A VIOLATION OF THE LAW FOR ti j j ti j II N ANY PERSON,UNLESS ACTING MIN BREAKER TO UNDER THE DIRECTION OF A zoanP I I EXISTING GROUN6lNG I HOUSE 240 V,15OAl2P I LICENSED PROFESSIONAL,TO (2)#12 Q-CABLES N ELECTRODE SYSTEM TO I (BOTTOM FED) ALTER AN ITEM IN ANY WAY.IF AN EARTH (E)MAIN SERVICE PANEL-2 (N)(1)JUNCTION — —� REF.NEC 250.52, I 200A RATED,240V ITEM BEARING THE SEAL OF A LICENSED PROFESSIONAL IS BOX 600V,NEMA �— — — 250.53(A) (INSIDE HOUSE) ALTERED,THE ALTERING LICENSED 4X RATED (E)MAIN SERVICE PANEL-1 PROFESSIONAL SHALL AFFIX TO I 200A RATED,240V THEIR ITEM THEIR SEAL AND THE (INSIDE HOUSE) (E) GENERATOR NOTATION"ALTERED BY 9@0! _ ~ I FOLLOWED BY THEIR SIGNATURE AND THE DATE OF SUCH ALION SPECIFIC DESCTERAT F RATION. wCL- MICROINVERTERS ONE UNDER EACH MODULE(240V) PHASE CONDUCTOR QTY,SIZE AND TYPE GROUND CONDUCTOR QTY,SIZE CONDUIT CONDUIT 079676 ID PER CONDUIT NEUTRAL QTY,SIZE AND TYPE PER CONDUIT AND TYPE PER CONDUIT SIZE TYPE OA� Iml 1 3 AWG#12 Q-CABLE NA NA NA 1 AWG#6 BARE,COPPER EGC N/A FREE AIR DRAWN BY MP 1A 2 AWG#12 Q-CABLE NA NA NA 1 AWG#6 BARE,COPPER EGC N/A FREE AIR DATE 9/17/2025 2 6 AWG#10 THWN-2,COPPER NA NA NA 1 AWG#8 THWN-2,COPPER EGC 1" PVC REVISION SIGNATURE 2A 4 AWG#10 THWN-2,COPPER NA NA NA 1 AWG#8 THWN-2,COPPER EGC 1" PVC 3 2 AWG#4 THWN-2,COPPER 1 AWG#4 THWN-2,COPPER 1 AWG#8 THWN-2,COPPER EGC V PVC PV-4 E EXISTING CONDUIT & CONDUCTORS ELECTRICAL CONTRACTOR AMBIENT TEMPERATURE SPECS COWER SOLUTIONS RECORD LOW TEMP -13°C PERCENT OF NUMBER OF CURRENT VALUES CARRYING CONDUCTORS IN CONDUIT LONG ISLAND POWER AMBIENT TEMP (HIGH TEMP 2%) 32°C SOLUTIONS CONDUIT HEIGHT 7/8" .80 4-6 2060 OCEAN AVENUE, ROOF TOP TEMP 54°C .70 7-9 RONKONKOMA, NY 11779 +1 631 348 0001 CONDUCTOR TEMPERATURE RATE 75°C .50 10-20 MODULE TEMPERATURE COEFFICIENT OF Voc -0.25%/°C PROJECT INFO&ADDRESS ISLE OF CEDARS LLC 2450 PETERS NECK RD, CALCULATIONS: ORIENT, NY 11957 1. CURRENT CARRYING CONDUCTOR 2. PV OVER CURRENT PROTECTION ...NEC 690.9(B). SYSTEM SIZE = TOTAL INVERTER O/P CURRENT x 1.25 DC SIZE:21.500 KW DC-(STC) (A) BEFORE IO COMBINER PANEL = (50 x 1.33) x 1.25 = 83.13 A NOTE: E AMBIENT TEMPERATURE - (32)OC ...NEC 310.15(B)(2)(`a) - BE THE BEST OF BELIEF AND PROFEE KNOWLEDGE,SSIONAL TEMPERATURE DERATE FACTOR - 0.94 ...NEC 310.15(B)(2)(`A) JUDGEMENT,THE PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH THE 2020 GROUPING FACTOR - 0.8...NEC 310.15(B)(3)(a) RESIDENTIAL CODE OF NEWYORK STATE. - IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING CONDUCTOR AMPACITY UNDER THE DIRECTION OF A LICENSED PROFESSIONAL,TO = (INV O/P CURRENT ) x 1.25 / A.T.F / G.F ...NEC 690.8(B) ALTER AN ITEM IN ANY WAY.IF AN ITEM BEARING THE SEAL OF A = [(10 x 1.33) x 1.251 / [0.94 x 0.81 LICENSED PROFESSIONAL IS ALTERED,THE ALTERING LICENSED PROFESSIONAL SHALL AFFIX TO = 22.11A THEIR ITEM THEIR SEAL AND THE NOTATION"ALTERED BY" SELECTED CONDUCTOR - #10 THWN-2 ...NEC 310.15(B)(16) FOLLOWED T THEIR SIGNATURE AND THE DATE OF SUCH ALTERATION SPECIFIC DESC � pFA' �y RATION. (B) AFTER IO COMBINER PANEL TEMPERATURE DERATE FACTOR - 0.94 GROUPING FACTOR - 1 �p 079676 �R CONDUCTOR AMPACITY DRAWN BY MP = (TOTAL INV O/P CURRENT) x 1.25 / 0.94/ 1 ...NEC 690.8(B) DATE 9/17/2025 = [(50 x 1.33) x 1.251 / [0.94 x 11 REVISION = 88.43 A SIGNATURE SELECTED CONDUCTOR - #4 THWN-2 ...NEC 310.15(B)(16) PV-4.1 ELECTRICAL CALCULATIONS CONTRACTOR CAUTION (POL_N Rs ` ' PHOTOVOLTAICPOWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE F-il e '• • = FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: LONG ISLAND POWER ELECTRIC SHOCK HAZARD SOLUTIONS IF A GROUND FAULT IS INDICATEDF71 . . OUTPUT 1 • • • • • N 2060 OCEAN AVENUE, NORMALLY GROUNDED CONDUCTORS RELOCATE OVERCURRENT DEVICE RONKONKOMA, NY 11779 MAY BE UNGROUNDED AND ENERGIZED PETER +1 631 348 0001 S NECK RD v o CAUTION,Z aRSELECTRIC R�/ 2 f 3�Jt7 k� 1 � °�' q �A SHO� PANEL-2 r 41bSYS TEM CONNECTED (IN ID E) PROJECT INFO&ADDRESS ELECTRIC SHOCK HAZARD `� r � ISLE OF CEDARS LLC THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAYBE ENERGIZED SOLAR PV SYSTEM EQUIPPED 2450 PETERS NECK RD 9] WITH RAPID SHUTDOWN ORIENT, Tus ` i "N f�13 � IIihBPANEL NY 11957 q SHUT DOWN PV SYSTEM AND REDUCE UTILITY DISCONNECT SYSTEM SIZE SHOCK HAZARD (OUTSIDE HOUSE) DC SIZE:21.500 KW DC-(STC) DO NOT TOUCH TERMINALS IN THE ARRAY ATS PANEL TERMINALS ON BOTH LINE AND (OUTSIDE HOUSE) LOAD SIDES MAY BE ENERGIZED UTILITY METER NOTE: IN THE OPEN POSITION (UNDERGROUND SERVICE) - TO THE BEST OF MY KNOWLEDGE, (OUTSIDE HOUSE) BELIEF AND PROFESSIONAL r CAUTION JUDGEMENT,THE PLANS AND SOLARyCIRCUIT MAIN SERVICE PANEL-1 SPECIFICATIONS ARE IN [4] e PV ARRAY (INSIDE HOUSE) COMPLIANCE WITH THE 2020 .. - RESIDENTIAL CODE OF NEW YORK STATE. authorizedprovider IT IS A VIOLATION OF THE LAW FOR • • s ANY PERSON,UNLESS ACTING ■ • . OUTPUT CURRENT1 AMPS UNDER THE DIRECTION OF A LICENSED PROFESSIONAL,TO DUALI'll IPOWERSOURCE ..-_ • •■ • 1 • ALTER AN ITEM IN ANY WAY.IF AN RECOND SOURCE ISPHOTOVOL-TAIC SYSTEM` ITEM BEARING THE SEAL OF A LICENSED PROFESSIONAL IS ALTERED,THE ALTERING LICENSED PROFESSIONAL SHALL AFFIX TO THEIR ITEM THEIR SEAL AND THE NOTATION"ALTERED BY" FOLLOWED BY THEIR SIGNATURE 6 AND THE DATE OF SUCH ALTERATION A SPECIFIC DESC ERATION. .71 C-) Solar Module Solar Module IQ COMPINEIR IN Micro Inverters PANEL AG BIGGGNNEGT PANEL PANEL-1 PANEL-2 — 11 1 1 1 1 1 L 6 6 6 3,9,10 3,9,10 3,9,10 Box Outside Door 3,6,8,9,11 � 2 3 Inside Door 6 Inside Door Inside Door FQ� 079676 Mbles should be marked by the manufacturer 5,167 5 6 7 5 6 7 Inside Door ' Solar Module Solar Module 5,67 *Custom *Custom *Custom DRAWN BY MP Micro Inverters Directory. Directory Directory NEC 690.54 DATE 9/17/2025 6 NEC 690.56(C) Placard Placard Placard REVISION Box NEC 705.12(B)(3) SIGNATURE 1 2 12(A) NEC 690.56(B) . NEC 690.56(B) NEC 690.56(B) Mbles should be marked by the manufacturer NEC 690.56(B)NEC 705.12(B)(3) NEC 705.10 NEC 705.10 NEC 705.10 PV-5 NEC 705.10 NEC 705.12(A) NEC 705.12(A) NEC 705.12(A) NEC 705.12(B)(3) NEC 705.12(B)(3) NEC 705.12(B)(3) LABELS 1 � , EAGLEO 54 66R 420-440 WATT • N-TYPE TOPCON Positive power tolerance of 0--+3% • NYSE-listed since 2010, Bloomberg Tier 1 manufacturer • Top performance in the strictest are party labs • Automated manufacturing utilizing artificial intelligence • Vertically integrated,tight controls on quality • Premium solar factories in USA,Vietnam,and Malaysia KEY FEATURES Superior Aesthetics �j�fJOff Black backsheet and black frame create ideal look for residential applications. N-Type Technology N-type cells with Jinko's in-house TOPCon technology • offers better performance and improved reliability. • To�„ Thick and Tough Fire Type 1 rated module engineered with a thick frame, 3.2mm front side glass,and thick backsheet for added durability. Shade Tolerant Twin array design allows continued performance even with shading by trees or debris. r Protected Against All Environments �� Certified to withstand humidity,heat,rain,marine environments, wind,hailstorms,and packed snow. Warranty 25-year product and 30-year linear power warranty. • IS09001:2015QualityStandards ISO45001:20180ccupational ', • IS014001:2015 Environmental Standards Health&Safety Standards Ow CE C U� us • IEC61215,IEC61730 certified products UL61730 certified products LISTED •S�O�CIPL BUILDING YOUR TRUST IN SOLAR.WWW.JINKOSOLAR.US •J%]''K® r ENGINEERING DRAWINGS MECHANICAL CHARACTERISTICS Front Side Back No.of Half Cells 108 12 x 54) 1134mm 4L.6S 1086mm 42.68' Dimensions- 1722 x 1134 x 35mm(67.79 x 44.65 x 1.38 inch) y� III ! IIIIII IIII I I',I IIIIIIIIII!III�I ! _ _H ! _ !2 !I!' IV'II ! Weight 21.Okg(46.3lbs) IIIIIIIIIIIIIIII. IIIII1 lli 111111 i ill 1111111111111Front Glass 3.2mm,Anti-Reflection Coating III !II illll B High Transmission,Low Iron,Tempered Glass -, li I ! I l ill '---6LL1---------�-------- -------_.- 11 in II !'!I IIIII II Frame Anodized Aluminum Alloy I I I !IIII I i'lll IIIIII ! I ❑ o -------------------n__._-__..-._- ___-- __T__--_-- llIIIII III !II IIIIIIIIIII IIII T Junction Box IP68 Rated E !IIIII! .III II'I IIIII': 'IIIII E Output Cables `12 AWG,1400mm 155.12ini or Customized Length II II II IIII IIII III IIIIIIIIII!II �____ J I!IIIII !Li F Connector Staubli MC4 _J I! II10ri, Fire Type Type 1 ! I' Pressure Ratin 5400Pa(Snow)&240OPa(Wind)*I • A IISupplemental Installation Manual forhigher windpressure rating solutions TEMPERATURE CHARACTERISTICS .............. ---• Length:t 2mm Temperature Coefficients of Pmax -0.29%/°C 9.0 Width:t 2mm Temperature Coefficients of Voc -0.25%/°C -� Height:t 1mm Temperature Coefficients of Isc 0.045%/°C '-- ------ ---- -. ` as Row Pitch:t 2mm I B p-p Nominal Operating Cell Temperature(NOCT) _- 4532°C ELECTRICAL PERFORMANCE&TEMPERATURE DEPENDENCE MAXIMUM RATINGS Current-Voltage&Power-Voltage Temperature Dependence Operating Temperature(*Cl -40°C-+85°C Curves 1420W1 ISOof Isc,Voc,Pmax Maximum System Voltage _- - - _-„�- 1000VDC 76 G20 Maximum Series Fuse Rating 25A 14 I60 350 12 140 a 10 280 3 120 2iB IN 6 'x PACKAGING CONFIGURATION L. _ a 140 Vol L v 80 z 20 = (Two pallets=One stack) ° ° E LO 0 s to is zo zs ao as 40 31pcs/pallets,62pcs/stack,806pcs/4C HO Container Lo Voltage(VI zo P Tj sOCellTemperature(°CI700 WARRANTY 25-year product and 30-year linear power warranty 111year degradation not to exceed 1%,each subsequent year not to exceed 0.4%,minimum power at year 30 is 87.4%or greater. ELECTRICAL CHARACTERISTICS Module Type JKM420N-54HL4-B JKM425N-54HL4-B JKM430N-54HL4-B JKM435N-54HL4-B JKM440N-54HL4-B STC - NOCT STC �NOCT -_ STC NOCT STC _- NOCT STC NOCT I __-_j Maximum Power(Pmax) 420Wp 316Wp 425Wp 320Wp 43OWp 323Wp 435Wp 327Wp 440Wp 331Wp Maximum Power Voltage(Vmp) 32.16V 29.95V 32.37V 30.19V _ 32.58V _ 30.30V 32.78V-- 30.50V--i32.99V - 30.73V _J Maximum Power Current(Imp) 13.06A 10.55A 13.13A 10.60A 13.20A 10.66A 13.27A 10.72A 13.34A 10.77A Open-circuit VoltagelVocl -�38.74V 36.80V 38.95V 37.00V 39.16V 37.20V 39.36V, 37.39V ^39.57V 37.59V J Short-circuit Current Ilsc) 13.51A 10.91A 13.58A 10.96A 13.65A 11.02A 13.72A 11.08A 13.80A 11.14A _Module Efficiency STC I%J 21.51% _ `21.76% `- - 22.02% -- 22.28%- �- --22.53%- 'STC: -' Irradiance 1000W/m2 Cell Temperature 25°C (f) AM= 1.5 NOCT:-;i;Irradiance 800W/m2 Ambient Temperature 200C � AM= 1.5 Wind Speed 1m/s *Power measurement tolerance:±3% The company reserves the final right for explanation on any of the information presented hereby.JKM400-420N-54HL4-B-F4-US BUILDING YOUR TRUST IN SOLAR.WWW.JINKOSOLAR.US .J/nK® t ' ENPHASE. BENPHASE oil WL IQ8MC Microinverter Easy to install Our newest IQ8 Series Microinverters are the industry's first microgrid-forming*,software- Lightweight and compact with plug- defined microinverters with split-phase power conversion capability to convert DC power to and-play connectors AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary Power line communication(PLC) application-specific integrated circuit(ASIC),which enables the microinverter to operate in between components grid-tied or off-grid modes.This chip is built in advanced 55-nm technology with high-speed Faster installation with simple two-wire digital logic and has superfast response times to changing loads and grid events,alleviating cabling constraints on battery sizing for home energy systems. High productivity and reliability EnphaseProduces power even when the grid is down* aA9 More than one million cumulative hours of testing Part of the Enphase Energy System, IQ8 Series Microinverters redefine Class II double-insulated enclosure IQ8 Series Microinverters integrate with reliability standards with more than one Optimized for the latest high-powered the IQ Battery,IQ Gateway,and the million cumulative hours of power-on PV modules Enphase App monitoring and analysis testing,enabling an industry-leading software. limited warranty of up to 25 years. Microgrid-forming Complies with the latest advanced grid �® support • Remote automatic updates for the , latest grid requirements • Configurable to support a wide range Connect PV modules quickly and easily IQ8 Series Microinverters are UL Listed of grid profiles , to the IQ8 Series Microinverters that have as PV rapid shutdown equipment and Meets CA Rule 21(UL 1741-SA)and IEEE integrated MC4 connectors. conforms with various regulations when 1547:2018(UL 1741-SB) installed according to the manufacturer's instructions. NOTE: • IQ8 Microinverters cannot be mixed together with previous generations of Enphase microinverters (IQ7 Series,IQ6 Series,etc.)in the same system. • 'Meets UL 1741 only when Installed with IQ System Controller 2 and 3. IQ Gateway is required to change the default gridprofile at the time of installation to meet the local Authority Having Jurisdiction(AHJ)requirements. , 2023 Enphase Energy.All rights reserved.Enphase,the a and CC logos,IQ,and certain other marks listed at httos://enphase.com/trademark-usage-quidelines are trademarks of Enphase Energy,Inc.In the US and other countries. Data subject to change. IQ8MC-MC4-DSH-00049-3.0-EN-US-2023-10-18 IQBMC Microinverter INPUT DATA(DC) UNITS .: Commonly used module pairings W 260-460 wModule compatibility To meet compatibility,PV modules must be within the following max.input DC voltage and max.module I," Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator. MPPT voltage range V 25-45 Operating range V 18-58 Min./Max.start voltage V 22/58 Max.Input DC voltage V 60 Max.continuous operating DC current A 14 Max.input DC short-circuit current A 25 Max.module Ix A _ - 20 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration Ungrounded array;no additional DC side protection required;AC side protection requires max 20 A per branch circuit OUTPUT DATA(AC) UNITS IQ8MC-72-M-US @240 VAC 108MC-72-M-US @208 VAC Peak output power VA 330 315 Max.continuous output power VA 320 310 Nominal grid voltage(L-L) V 240,split-phase(L-L),180° 208,single-phase(L-L),120° Min./Max.grid voltage 2 V 211-264 183-229 Max.continuous output current A 1.33 1.49 Nominal frequency Hz 60 Extended frequency range Hz 47-68 AC short circuit fault current over three A 2.70 cycles I " Max.units per 20 A(L-L)branch circuit 3 12 10 Total harmonic distortion <5 Overvoltage class AC port III AC port backfeed current mA 18 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading...0.85 lagging Peak efficiency % 97.4 97.2 CEC weighted efficiency % 97.0 96.5 Nighttime power consumption mW 33 25 MECHANICAL DATA UNITS Ambient temperature range -40°C to 65°C(-40°F to 149°F) Relative humidity range 4%to 100%(condensing) DC connector type Staubli MC4 Dimensions(H•W•D);Weight 212 mm(8.3")•175 mm(6.9")•30.2 mm(1.2");1.1 kg(2.43 Ibs) Cooling Natural convection-no fans Approved for wet locations;Pollution degree Yes;PD3 Enclosure Class II double-insulated,corrosion-resistant polymeric enclosure Environ.category;UV exposure rating NEMA Type 6;outdoor CA Rule 21(UL 1741-SA),UL 62109-1,IEEE 1547:2018(UL 1741-SB),FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017,NEC 2020,and NEC 2023 section 690.12 and C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's instructions. (1)No enforced DC/AC ratio. (2)Nominal voltage range can be extended beyond nominal if required by the utility. (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8MC-MC4-DSH-00049-3.0-EN-US-2023-10-18 c Revision history REVISION DATE DESCRIPTION DSH-00049-3.0 October 2023 Included NEC 2023 specification in the Compliance section. I DSH-00049-2.0 September 2023 Updated module compatibility information. DSH-00049-1.0 May2023 Preliminary release. ©2023 Enphase Energy.All rights reserved.Enphase,the a and CC logos,IQ,and certain other marks listed at https://enphase.com/trademark-usage-quidelines are trademarks of Enphase Energy,Inc.in the US and other countries. Data subject to change. IQBMC-MC4-DSH-00049-3.0-EN-US-2023-10-18 l 1 ®lr IRONRIDGE Roof Mount System Built for solar's toughest roofs. IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Software Certified to maintain the fire resistance ® Online tool generates a complete bill of rating of the existing roof. materials in minutes. Integrated Grounding 20 Year Warranty ® UL 2703 system eliminates separate Twice the protection offered by module grounding components. competitors. XR Rails XR10 Rail XR100 Rail XR1000 Rail Internal Splices Q A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability • 8'spanning capability 12'spanning capability Self-tapping screws • Moderate load capability • Heavy load capability Extreme load capability Varying versions for rails • Clear& black anod.finish • Clear& black anod.finish Clear anodized finish Grounding Straps offered Attachments FlashFoot Slotted L-Feet Standoffs Tilt Legs ,let, Anchor,flash, and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired with all-in-one attachments. attachment. systems to various heights. angle, up to 45 degrees. • Ships with all hardware High-friction serrated face Works with vent flashing Attaches directly to rail • IBC& IRC compliant Heavy-duty profile shape Ships pre-assembled Ships with all hardware • Certified with XR Rails Clear&black anod.finish 4"and 7"Lengths Fixed and adjustable Clamps & Grounding End Clamps Grounding Mid Clamps Q T Bolt Grounding Lugs Q Accessories LLhk s � i. Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails. • Mill finish &black anod. • Parallel bonding T-bolt • Easy top-slot mounting Snap-in Wire Clips • Sizes from 1.22"to 2.3" • Reusable up to 10 times • Eliminates pre-drilling Perfected End Caps • Optional Under Clamps • Mill&black stainless • Swivels in any direction UV-protected polymer Free Resources Design Assistant /♦® NABCEP Certified Training Go from rough layout to fully s Earn free continuing education credits, _--•--_--- engineered system. For free. ®, while learning more about our systems. Go to IronRidge.com/rm ®®� Go to IronRidge.com/training