Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
52432-Z
.��'aof s°ulyo�o Town of Southold * * P.O. Bog 1179 0 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46928 Date: 03/25/2026 THIS CERTIFIES that the building HVAC Location of Property: 1265 Sound Rd Greenvort, NY 11944 S ecB lock/Lot: 3 3.-4-76 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 09/29/2025 Pursuant to which Building Permit No. 52432 and dated: 11/03/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "As built" HVAC system as applied for. The certificate is issued to: Victoria Moran Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 52432 3/24/2026 PLUMBERS CERTIFICATION: Authorized Signature Fso�ryD TOWN OF SOUTHOLD BUILDING DEPARTMENT `� • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52432 Date: 11/03/2025 Permission is hereby granted to: Victoria L Moran 4 Knoll Ct Lloyd Harbor, NY 11743 To: Legalize an "as built" HVAC system as applied for according to manufacturer's specifications. Premises Located at: 1265 Sound Rd, Greenport, NY 11944 SCTM#33.-4-76 Pursuant to application dated 09/29/2025 and approved by the Building Inspector. To expire on 11/03/2027. Contractors: Required Inspections: Fees: As Built HVAC $500.00 CO-RESIDENTIAL $100.00 Total $600.00 jxy�,� Building Inspector ho��OF SO(/TyOlo Town Hall Annex Telephone(631)765-1802 54375 Main Road N 92 P.O.Box 1179 � Southold,New York 11971-0959 ���COUNV,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Victoria Moran Address: 1265 Sound Road City: Greenport st: NY zip: 11958 Building Permit#: 52432 Section: Block: Lot: WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Electrician: License No: SITE DETAILS Office Use Only Commercial Indoor X Basement Service Solar Residential X Outdoor X 1st Floor Pool Battery Storage As-built X Renovation 2nd Floor Hot Tub EV Charger New Addition Attic Spa Generator Survey Mezzanine Garagel IDock INVENTORY Service 1 ph In-wall Heater Recpt Ceiling Fixtures Smoke Detectors Pump Service 3 ph Hot Water GFCI Recpt 2 Wall Fixtures CO Detectors Heater Main Panel A/C Condenser 1 Single Recpt RecessdFixtures Combo Smoke/CO Transformer Sub Panel A/C Blower 1 Range Recpt Ceiling Fan Heat Detectors Salt Gen Transfer Switch Mini Split Dryer Recpt UC Lights Fridge AutoCover ARC Blower Heads Switches 1 Pucks Lights Dishwasher Mini Fridge GFI SepticDisconnect Emrgency Strobe 4'LED Microwave Garbage Disp. ARC/GFI ERV Exit Lights Bath Exhaust Hood Dehumidifier Other Equipment: Notes: HVAC AS BUILT Inspector Signature: Date: March 24, 2026 %� ��OF SOUTyO TOWN OF SOUTHOLD BUILDING DEPT. couto 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [FINAL WVA6, [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ .] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: As—— kilt-LI DATE INSPECTOR gSOUIy� a TOW OF SOUTHOLD BUILDING DEPT. °y o m��`' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ]- FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [kl ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS:iq V e UJA 6' J e'r V i Gel vw eawS fA ah4 c y iG� ou f� vL 0:061G DATE .,. INSPECTOR d� FIELD INSPECTION REPORT DATE COMMENTS �►o t� FOUNDATION (1ST) -------------------------------------- FOUNDATION (2ND) i �10 vl ROUGH FRAMING& r PLUMBING W _ 1 1 � r INSULATION PER N.Y. STATE ENERGY CODE Yh FINAL ADDITIONAL COMMENTS -1 COt 2 ic- cZ � o �x y G b y TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 A YY t Date Received For Office Use Only ® E V E PERMIT NO. 5a� aBuilding Inspector: S E P 2 9 2025 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Biullding Department Owner's Authorization form(Page 2)shall be completed. Town of Southold Date:August 21 st, 2025 OWNER(S)OF PROPERTY: Name:Victoria Moran SCTM#1000- .- L f_ '7tp Project Address:1265 Sound Road, Greenport, NY 11944 Phone#:516-528-3798 Email:victoriamoranpt@gmail.com Mailing Address:1265 Sound Road, Greenport, NY 11944 CONTACT PERSON: Name: V ` C (LCI b( .in Mailing Address: L I LI n Phone#: — 5 �'�2J Email: C�n 0Cn /V t 014 DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name:Franco`Qliveri-Apple Mechanicals Mailing,Address:56 Carleton Ave, Islip Terrace, NY 11752 Phone#:631-484-5974or 631-581-7378 Email:applemechanicals@gmail.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration BRepair ❑Demolition Estimated Cost of Project: []Other IiVA-L. "' ASS bUl f $ Will the lot be re-graded? Dyes RNo Will excess fill be removed from premises? Dyes AND 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ❑No IF YES, PROVIDE A COPY. ❑ The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter Z36 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):Victoria Moran ❑Authorized Agent BOwner Signature of Applicant: Date: 8/21/25 STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Victoria Moran being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Homeowner (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this o 20 �C -L4h day f�-/I�.esr��� _ otary Public DANIEL MICHAEL PEREDO Notary Public-State of New York NO,01PE6445032 Qualified in Suffolk County (Where the a I`kS `N'Ps�i'ditHW rVe 26 ,, Victoria Moran residing at 1265 Sound Road, Greenport, NY 11944 Franco Oliveri do hereby authorize to apply on my b a t t e o of Southold Building Department for approval as described herein. sit � � � ner's Signature Date Victoria Moran Print Owner's Name 2 e4:�"A S�fFO(�� BUILDING DEPARTMENT- Electrical Inspector OG TOWN OF SOUTHOLD o3 Town Hall Annex - 54375 Main Road - PO Box 1179 �- Southold, New York 11971-0959 C �� - Telephone (631) 765-1802 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFO ON (All Information Required) Date: Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: J,\cAw\60 rG(1 Address: Cross Street: Phone No.: Bldg.Permit#: F3V12og email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Q� `D v1 lk "\� kc- Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame D Pole Work done on Service? D Y N Additional Information: PAYMENT DUE WITH APPLICATION `M f Vlot BUILDING DEPARTMENT- Electrical Inspector ,fZOSU�FO(�-CPS TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 o Southold, New York 11971-0959 Telephone (631) 765-1802 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFO ATION (AII Information Required) Date: Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: 1,\On C\ of-oo Address: -- Cross Street: Phone No.: Bldg.Permit#: Fay�)q email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE.(Please Print Clearly): kC Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals D 1 2. H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION 1 `ten J PERMIT# Address: Switches Outlets G F I's Surface Sconces H H's UC Lts Fridge HW POOL Panel Fans Mini Fr. W/D Pump Exhaust Oven Sump Heater Trnsfrnr Smokes DW Generator Salt Gen. Water Bond Carbdn M.icro Grb.Dis Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments ,l SURVEY OF PROPERTY SI TUA TE: N/F DEBORAH CUTLER I RAYMOND NORTON NORTH OF THE VILLAGE OF GREENPORT, TOWN OF SOUTHOLD# END ,. FENCE o SUFFOLK COUNTY, NEW YORK N62 21 30 E f. 105.00 o.sN .i 6' STOCKADE FENCE FENCE 0.3'N J 4' PVC FENCE 4.0'W�. �a m S,C,T M. 1000—033.00—04.00-076.000 w HEDGE ROW 0 oaz SCALE: 1°=20' W z N CARPORT CONC. DRIVEWAY aU¢ Z U w is. G LINT O W o o VOA POLE Wm w 0 4.1' Z 9 35.9' w CIE z °yP W a NOTES z >- co OVERHEAD° R w O 1. PROPERTY ADDRESS: 1265 AKA 49 SOUND DRIVE, GREENPORT, NEW YORK, 11944. ! C �M 2. LOT AREA = 7,875 SQ.FT. (0,181 ACRES). a z c, I— N i DO o 3. PROPERTY CORNER MONUMENTS WERE NOT SET AS A PART OF THIS SURVEY. N O :� w .Qj 4. ALL DISTANCES ARE 1N US SURVEY FOOT. j JSHED361E L 5. SURVEYED ON-MAY 10, 2025.28. ' 36.2'FRAME HEDGE ��nnL 01.2N V,HEDGE ROW 1.8'W I a DENNIS W. LAYTON GA. GAR. 2 s S62 o21'30"W 105-00' t I PROFESSIONAL LAND SURVEYOR GARAGE NEW YORK LICENSE NO. 050920 N%F ANDREW CORWIN CERTIFIED T0= I KlMBERLY CORWIN OF N FIRST AMERICAN TITLE INSURANCE COMPANY Y AMERICAN DREAM ABSTRACT, INC. ADAW9360-S 'A t LOGAN FINANCE CORPORATION VICTORIA L. MORAN SUTTON PLACE C), 2c1 OSno90 COMPLY WITH ALL CODES OF APPROVED AS NOTED NEW Y RK STATE&TOWN CODES a AS RE IRED AND CONDITIONS OF DATE:IL-�: 5_B.P# SOUNLDIDUM FEE �� • O BY. _.SOUTHOLD70MANNNOMM SOIlTHOLD7a��� NOTIFY BUILDING DEPARTMENT AT 631-765-1802 8AM fry 4PM FOR THE NY.&DEC FOLLOWING INSPECTIONS: SOUDIOLDW FOUNDATION -TWO REQUIRED SAID FOR POURED CONCRETE ROUGH- FRAMING&PLUMBING INSULATION FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS ELECTRICAL INSPECTION REQUIRED Additional Certification May Be Required. NMG**F1P LE Series ENHANCED AIR HANDLER SPECIFICATIONS. PSC'Motor Application • 2-5 ton systems Constant Torque Motor - • Sequenced for demand management (4 and 5-Ton Models Only) • External access to heater circuit breakers Installation _ • 1 piece design - " MoM _ _ • Smaller profile for closet applications w • Multi-position = Upflow/Horizontal Left/Right • Approved for installation in manufactured housing and mobile homes r r Cabinet • Foil faced insulation for enhanced indoor air quality • Double hemmed technology for increased structural rigidity • Improved gasketing on doors to prevent air leaks - • Filter rack with thumb screws for easy access and removal • Polymer plugs on drain locations for easy installation • Baked polyester paint finished over galvanized steel for maximum durability • High-strength/heat resistant/corrosion resistance SMC drain pans • Antimicrobial treated polymer drain pan built to resist mold and mildew growth • 2%or less air leakage r. s:. I _¢ Coils • Total corrosion protection technology designed coil • Enhanced tube-and-fin coil design featuring MHTTm Technology • Lanced fins for maximum heat transfer • Factory leak tested and pre-charged with nitrogen holding charge Components • Efficient PSC blower motors (4 and 5 ton units utilize constant torque motor) • Standard transformer and blower relay • Field installed 5-20kW electric heat kits with easy plug connections • Blower time delay for increased efficiency • Sleeves on distributor tubing to protect tubes ETA �S Intertek partsNow Warranty-6 years on (Some limitations .pply;see printed warranty for d- MODEL NUMBER GUIDE DX Air II 'Green'003 Copnoily1 1 1 I I Power Handler 0A BTUH x 1000 with PSC Drive 1 208/230-1-60 Revision Alloy PHYSICAL RefrigerantConnection1 Model1 Available Suction HMG24F1P 208-230/60/1 10 40 VA Class 2 15X20 3/4 3/8 127 H10100F.1 P` =�208-230/60/11 115 40 VA.Class 2 15X20 - 3/4 3/B ;°;133. HM036FI P 208-230/60/1 15 40 VA Class 2 18X20 7/8 3/8 163 "HMG42F10 208-230/60/1 . 15. ' '40 VA,Olass 2' 18x20 .7/8 3/8 : 168 HMG48F1P 208-230/60/1 20 40 VA Class 2 18x20 7/8 3/8 186 HN1660FiP_ 208-230/60/1,' 20 :40.VA Class 2. :18x2O' '7/8 3/8, 186.,, INSTALLATION CLEARANCES WITH ELECTRIC HEAT CABINET 0 inch(0 mm) 1 Units installed on combustible floors in the down- flow position with electric heat require optional TO PLENUM O mch(Omm) downflow combustible flooring base. TO OUTLET DUCT WITHIN 3 FEET(914 MM) 0 inch(0 mm) 2 Front service access-24 inches(610 mm) minimum. FLOOR 0 inch(0 mm)See Note#1 = Note-If cabinet depth is more than 24 inches SERVICE/MAINTENANCE See Note#2 (6-10mm),allowa-minimum-of-the-cabinet-depth---- - plus 2 inches(51 mm). ELECTRIC HEAT Size Model C/B Size WHERE Electric Heat Kits with Terminal Block 5 kW ECBA25-5 NA 18,24.30,36,42,48,60 16Y36 7.5 kW ECBA25 7.5 NA, 18,24,30,36,42 48,60 i 6Y37 10 kW ECBA25-10 NA 24,30,36,42,48,60 16Y38 Electric Heat Kits with Circuit Breaker 5 kW ECBA25-5CB 30A 10,24,30,36,42,48,60 16Y39 7.5 kW ;• ECBA25=7,,.5CB 45A ' 18 24;W,36,42 48,60 16Y41. 10 kW ECBA25-10CB 60A 24,30,36,42.48,60 16Y42 12.5 kW- ECBA25-12.5CB ` ,;5ON+.25A'•_; '3D-36,42,48,60'.` • 16Y43 15 kW ECBA25-15CB 60A+25A 30,36,42,48,60 16Y44 ECBA25-20CB 60A+50A 48,60 16Y46' Replacement Circuit Breakers(2 pole) Volts Size Cat# 25A 41 K13 30A _ 17K70 35A 72K07 208/240V-1 phase 45A 17K71 50A 41 K12~ 60A 17K72 *Circuit breaker must match rated"Max C/B Size';replace breaker as necessary. d i, j ELECTRICAL Heating Capacity(24011) Min.Circuit Ampacity Max.Circuit Breaker Size Single Point Power Supply 208V 240V 208V 240V 20 240V Nominal Blower Model Heater I k. Btuh Amps 1 2 1 2 1 2 1 2 Amps F.�e Amp�T]Fuse 0 0 0 5 5 15 15 HMG24F1 P 1.6 5 4.8 16400 24 27 25 30 7.5 7.5 25600 36 41 40 45 10 9.6 32700 45 52 45 60 0 ':0 0 -5.0 5 15 i 15 5 4.8• .1'' 00, 24 .; :. 28'- 25 30 7 5 7,5 25600 37 42 . . . :-40 45 , HMG30F1P 2.2' 10 9.6' 32700 46 -53' 50_ BO 12:5 `12:5 42600 40 19 46 `..'22 ;40' 20 50• .25 59 60 - ' 68 70 15 '14:4 49100 46 - 22 53` 25.- SO-- '25 60- 25 , 68.: 70 78, 80 0 0 0 5 5 15 15 5 4.8 16400 24 28 25 30 7.5 7.5 25600 36 42 40 45 HMG36F1P 2 10 9.6 32700 46 53 50 60 12.5 12.5 42600 40 19 46 50 40 20 50 25 59 60 68 70 15 14.4 49100 46 22 53 25 50 25 60 25 68 70 78 80 , .p ..:, 0 0" ,< 5.0 5:0 15 15, 5 ..' , 4:8 16400 25 28 25 ' .: " '30 HMG42F1 P 7:5 7.5•• 25600 - 2.5 ;37 42 40 45., 10 9.6' 32700' • 46 53 50- 60 12:5 12.5 42600 41 19 47 ';22'! 45 ` 20 50 .;25' 60 '60 68, 70 15:, 14,4 49100 46' 22 53 .; 2550 25 25 0 0 0 9.5 9.5 15 15 5 4.8 16400 31 35 35 35 7.5 7.5 25600 43 49 45 50 HMG48F1P 10 9.6 32700 7.6 53 60 60 60 12.5 12.5 42600 47 19 53 22 50 20 60 25 66 70 75 80 15 14.4 49100 53 22 60 25 60 25 60 25 75 80 85 90 20 19.2 65500 53 43 60 50 60 45 60 50 96 100 110 110 0: 0, D 9.5,, 95 .: ".' .15 " 15`• S 4.8 : 16400 31'; 35.' -35, 35, 75' Z.5 25G00 43 .'49 45 50 HM660FIP f0 + , 9.6. 32700. 7.6 53;. 60,' 60' 60 125 12.5 .• 42600" 47, 19 53 ,22. 50' 20 60 .25 66 • 70 7.5 80, = 15 14.4 -49100 51 22. '60 25 . 60" 25 ;-,.60' 25. 75 8D 85 .. ; 90. 20;. 19.2 6550D .", 53' 43' 60- 'SO. 60" 45` :60,. -50 96`.. 100 1,10 110' 1. for 208 volt use.751 correction factor for kW and Btuh 2. 12.5kW,,15 and 20kW(2 stage models)require 2 supply circuits 3. Circuit#1 includes blower motor amps except 20kW models BLOWER Model Motor Size Blower Size Speed Tap CFM @ ESP-in.W.C. Low(Red) 675 675 655 630 590 . HMG24FIP 1/3 9X6 Med(Blue) 1010 . 980- 940- 805 740 High(Black) 1105 1045' 1000 915 855 . ow(Red) .�';, V0 m- 870 'w 855•� 810'• 770 HMG30F1P 1/2 ';10X8 Med'(Blue) :.1080;. `.. 1055 1025 985 935. - High(Black) 1310;Y• 1 .260`, 1255 ; "i155 -1085 Low(Red) 1020 970 955 910 805 HMG36F1P 1/3 10X8 Med(Blue) 1275 1240 1190 1150 1085 High(Black) 1560' 1520 1445 1395 1325 Liiw:(Redj 1300=: 1275 1250:,' .1 :1155> ` - 'HMG42F1P 1(2 10X8I Med(Blue) 1525`` 1495 1450 _ 1390 - i345; High(Black) ,•1815 , 1755'., 1695' 1605 1530`. Low(Red) 1250 1210 1185 1130 1110 Med-Low 1500 1465 1435 1400 1360 HMG48F1P 1 12X10 Med(Blue) 1715 1670 1635 1615 1575 Med-High 1770 1735 1700 1670 .1650 High(Black) 1895, 1860 1835 1795 1760 Low'(Red)'- 1100 1050 4000- •.925 '630 a. Med-Low 1625.:,� 1595 ;1565 1520 1490- HM660FIP 1 12X10. s,Med(Blue) 1815 f 1785 1160`- 1730 1685 Med-High 1905.' 1870 1835- 1810 -_-1765� Higli(Black) 1980 -` 1955 1925- 1895 1860 All data given while air handler is operating with a wet DX coil and air filter installed. Speeds marked in italics with an asterisk are the factory settings for both heating and cooling.Cooling speeds should not be reduced below factory settings. Different speeds can be set for heating mode. DIMENSIONS (IN.) (25) DETAIL OF PIPING PLATE ' SUCTION (H21) SUPPLY A!R I LINE OPENNG L#2U1D 14.912 ' LKE MMENSATE ( ) . 2318 ©-"{ H(25) C 1 p) 0 - COt, NSATE' l 4-31a. wwtz 9) 1 , ' -+ + 0 (upto'w&-14 ttnHi LOW VOLTAGE 23<1 Da 'Ltrw)0- POLETS I11 (To and Rol5,de) / 3 H!2 ' LINE VOLTAGE / 13.w ) ' lf&ETS / 4 (Top and Celt SA-3) TOP VIEW / ———— A) -------� 22 {T9) 9 uw-VOLTAGE ( ) I mETTs ClF=ff LOW VOLTAGE aREAY01"� / NLETS COVER / q£:aeerSCa) At / O / AIR FLOW / / A / PIPNG / PLATE / / COMENSATE ORAN sucTto:V PlPlt¢G PLAT E(3) LLNE (2-1A x 3.3t3) LIOUD LINE FILTER LINE ACCESS112 vs I (29) 1 MEMO ! (29) , (a) 1 (s,a) (29) OPENING FRONT VIEW SIDE VIEW ( 4 030 036/042 048 060 I A 45-1/2 1156 47 1194 53-5/8 1362 55 1397 59-3/4 1518 1871/2 C 16-1/2 419 16-1/2 419 19-1/2 495 19-1/2 495 19-1/2 495 'D 489 161%4 ' 413n 16Tf/4 ' 41,3 y:9,1/4 f:. ,,`r19-1/4191/4 F; ACCESSORIES MORIPTION 18,24,30 H4TXV01 TXV Kit 36,42,48 H4TXV02 60 H4TXV03 Downflaw Kit Y9658A 60 Y9859A , Downflow Combustible Floor Base Kit 18,24,30 12W95 36,42,48,60 12W96 - •`.Horizantai�SuPportFrameKd� N` �; AII�Madels �:SFit1H Side Return Unit Stand(upflow only) All Models 45K32 }. Single Point Power Kit All'Models, 21H39 Wall Hanging Bracket Kit(upflow only) All Models 45K30 Higti.PQrformanee;Economizer{Commercial rly) �Ail,Modeis '�; �,-10U59 "This product complies with all California product labeling laws including,but not limited to,the Safe Drinking Water and Toxic Enforcement Act of 1986, more commonly known as Proposition 65." Due to ongoing product improvements,specifications and dimensions are subject to change and correction without notice or incurring obligations.Determining the application and suitability for use of any product is the responsibility of the installer. Additionally,the installer is responsible for verifying dimensional data on the actual product prior to beginning any installation preparations. Third party incentive and rebate programs have precise requirements as to product performance and certification. All products meet applicable regulations in effect on date of manufacture,however certifications are not necessarily granted for the life of a product. Theroforo,it in tho rosponcibility of tho applicant to determine whother a specific model gnalifik Inr thpcp inrentivp./rrhatr,programs. i �l Ll LS.Y4'fRdtVk'd� { �$ i tlSigttarmry�u�4;r�tit�#KdFiA,�6�; '' T sazr/rzrzacar�rcrtrsrEc t90A,t ''d►rordhAucs�m}M�}f92[3 451F78r 100 arsamutre a , .r«.e.„......�.,.•....,.�..,.....,�«_.ta-a.wm..,.«..4......X_d.wa...s...�..w.....,..e...,...+..�x..»�_...-....»..�,,....:.�,,.....i✓.,...-...>raa,...'.�st..�i.}1i.,ys...=.._....«.�..,...�,..�_—.....1....�t........,..,...«.m..w...s...r...«�......,....»�.....r-... R SG14 ' ACCESSORIES Descrilpflon Where Used Kit Number Purpose Prevents liquid migration to the Liquid Line Solenoid All models 6OM52 compressor especially for high liquid riser applications 18 1 OJ42 Scroll compressors usually do not Hard Start require hard start;maybe needed 24 thru 60 88M91 for utility brown-out or low voltage areas 18,24,30,36 93MO4 Crankcase Heater 42 93MO5 Prevents liquid migration to compressor in cold weather 48,60 Factory Installed Compressor Short Cycle Protector All models 47J27 Delays compressor start 5-7 minutes to prevent short cycling Enables cooling demand down to Low ambient(cooling operation) All models 34M72 30 OF. Will require freeze stat,CC heater and TXV Loss of Charge Kit All models 84M23 Protects the compressor if refrigerant charge is too low 18,24,30,36 14WO0 Sound Cover Lowers compressor sound level 42,48,60 14WO1 Additional System Accessories(indoor section) 18,24,30 H4TXV01 TXVs provide superior refrigerant TXV Kit 36,42,48 H4TXV02 flow control,comfort and efficiency 60 H4TXV03 compared to pistons Outdoor Thermostat-Electric Heat All models 1OZ23 Prevents electric heat operation above specific ambient conditions Outdoor Thermostat-Mounting Box All models 31461 Mounting box for outdoor thermostat Freezestat All models 93G35 Protects the compressor at low suction pressure conditions Turn the system off,if condensate Overflow Switch All models 11 u 5 water overflows due to clogged drain pipes Blower Time Delay All models 58M81 Improves system efficiency and comfort Single Point Power Supply All models 21 H39 Provide single power source in one junction box Auxiliary Blower Relay All models 85W66 Maybe required to select multiple indoor blower speeds Due to ongoing product improvements,specifications and dimensions are subject to change and correction without "This product complies with all California product notice or incurring obligations.Determining the application and suitability for use of any product is the responsibility labeling laws including,but not limited to,the Safe of the installer.Additionally,the installer is responsible for verifying dimensional data on the actual product prior to beginning any installation preparations.Third party incentive and rebate programs have precise requirements as to Drinking Water and Toxic Enforcement Act of 1986, more commonly known as Proposition 65." product performance and certification.All products meet applicable regulations in effect on date of manufacture; however,certifications are not necessarily granted for the life of a product.Therefore,it is the responsibility of the applicant to determine whether a specific model qualifies for these incentive/rebate programs. '2024 MOTORS a ARMATURM Lie. MARS V.a 1nat I W WKbr'vk d M3WM SArMN00,1n[. cornkn A m.:o-eQeenra redrrwk d Wom 6 AMVM w,Mc SP-2M 2/24 CA-RSG14S1R SPEC 1900 Weltworth Ave,Jackson Mil 49203 • 517.787,2100 • www comfort-a+re.com COOLING PERFORMANCE WITH OTC' IndoorCapacity Outdoor Model RSG1418S1R (C,M)CG24P(A,B,C)4P+TXV+TD 17,900 11 13A RSG1424S1R (C,M)CG24P(A,B,C)4P+TXV+TD 23,600 11.7 13.4 RSG1430SlR (C,M)CG36P(A,B,C)7P+TXV+TD 28,200 11.5 13.4 RSG1436S1R (C,M)CG3036P(A,B,C)EP+TXV+TD 34,000 11.5 13.4 RSG1442S1R (C,M)CG4248P(C,D)BP+TXV+TD 39,500 11 13.4 RSG1448S1R (C,M)CG48P(B,C,D)FP+TXV+TD 45,500 11.5 13A RSG1460SlR (0,M)CG60P(C,D)BP+TXV+TD 56,500 11.2 13.4 1 DTC=Designated Tested Combination SOUND RATINGS Estimated Sound Pressure(NA)l Approximate Distance 3 Model Sound Power' (11 Meter) (2 Meters) (3 Meters) RSG141BS1R 73 65 59 55 RSG1424S1R 76 68 62 58 RSG1430SlR 76 68 62 58 RSG1436S1R 76 68 62 58 RSG1442S1R 76 68 62 58 RSG144BSlR 78 70 64 60 RSG1460SlR 80 72 66 62 1 Rated in accordance with AHRI standard 270(2015).AHRI Standard 270 establishes a method of rating outdoor unitary equipment in terms of Sound Power. 2 Rated in accordance with AHRI standard 275(2010).AHRI Standard 275 provides the calculations for estimating the A-Weighted Sound Pressure at a given distance from the equipment.That is a more useful number because that is what humans will hear. 3 Based only on distance factor;other factors may change this value such as: Unit location(reflective surfaces adjacent to the unit) Barrier shielding sources Sound path/elevation Outside noise sources 00? f 1 � MODEL NUMBER GUIDE Residential Split 'Green'Gas Minimum SEER Capacity S =Scroll Power Series/ Condenser System R-41 OA BTLIH x 1000 Compressor 1 = 208/230-1-60 Revision PHYSICAL AND ELECTRICAL DATA Max. Compressor Outdoor Fan Motor DeviceMin. Current Rated Locked Fu I I Voltage Circuit Model Voltage/HZ/Phase Range Amp. (amps) amps (amps) (amps) HP RPM RSG1418S1R 208-230/60/1 197-253 12.0 20 9.0 56.3 0.7 1/10 1075 RSG1424S1R 208-230/60/1 197-253 14.6 25 10.9 62.9 1.0 116 825 RSG1430SlR 208-230/60/1 197-253 17.0 25 12.8 67.0 1.0 1i6 825 RSG1436S1R 208-230/60/1 197-253 18.8 30 14.2 80.6 1.0 1/6 825 RSG1442SIR 208-230/60/1 197-253 21.9 1 35 1 16.7 1 113.0 1 1.0 1 16 825 RSG1448SiR 208-230/60/1 1 197-253 24.8 40 18.5 94.0 1.7 1/4 825 RSG1460SlR 208-230/60/1 1 197-253 29.6 50 22.2 127.9 1.8 1/3 825 Note: Weights litsted are unit weights with packaging+Factory charged for 15 feet of line set. Adjust per installation instructions. UNIT DIMENSIONS & SOUND RATINGS / BModel Weight Dimensions(inch) Shipping D• RSG1418S1R 24-114 24-114 29 134 RSG1424S1R 28-1/4 28-1/4 29 154 RSG1430SlR 28-1/4 28-1/4 37 169 RSG1436S1R 28-1/4 28-1/4 29 181 c RSG1442S1R 28-1/4 28-1/4 37 211 RSG1448S1R 28-1/4 28-1/4 37 218 Q RSG1460SlR 32-1/4 32-1/4 43 226 Note: Dimensions listed are unit sizes w/o packaging REFRIGERATION DATA Refrig.Charge Refrigerant Line Size Outdoor Unit Connection Indoor Unit Connection Model (oz.) Piston Size TXV Suction Suction Suction Suction Suction Liquid RSG1118SIR 62 0.049 H4TXV01 314 3'8 3`4 318 3'4 3/8 RSG1424S1R 81 0.057 H4TXV01 3/4 3/8 3/4 3/8 3/4 3/8 RSG1430SlR ill 0.060 H4TXV01 3/4 3/8 3/4 3/8 3/4 3/8 RSG1436S1R 121 0.067 H4TXV02 7/8 3/8 7/8 3/8 7/8 3/8 RSG1442S1R 146 0.076 H4TXV02 7/8 3/8 7/8 3/8 7/8 3/8 RSG1448S1 R 152 1 0.083 H4TXV02 7/8 3/8 7/8 3/8 7/8 3 8 RSG1460SlR 203 0.097 H4TXV03 1-1/8 3/8 7/8** 3/8 7/8 3:8 *Factory charged for 15 feet of line set **Adapter shipped with unit R **SIR SG14 LE Series _WWWOSPLIT AIR CONDITIONER SYSTEM SPECIFICATIONS Minimum Efficiencies., :• High-efficiency scroll compressor < 65KBtu. 13.4 SEER2+ • R410A refrigerant • Heavy-duty compressor sound blanket for quiet operation (optional accessory) • Internally protected against high temperature motor overload conditions Cabinet • Full metal louvered construction to protect the coil/hail protection {l1lll ( • Individual louver panels; for ease of coil cleaning and service i11111111 Illl�li } ff • Corner-mounted controls for easy service • Baked polyester paint finished over galvanized steel for ��f��l��) I � f [[•." "" maximum durability • 45-degree offset valves for easy service '��Illllll illlllr��i���� F. � Coils • Total corrosion protection technology designed coil • Enhanced tube-and-fin coil design • Lanced fins for maximum heat transfer • Every coil factory tested for leakproof construction • Raised coil prevents debris from impeding airflow Components L r� • Factory installed high pressure switch °ETI►°S • Thread-on pressure switches for simple, quick replacement Intertek • Filter drier shipped loose for installation flexibility • ' ' • Fan shroud for smoother airflow and sound level reduction y • Charged for 15 feet of line set For the latest AHRI system matches, please visit www.marsdeliversratings.com or AHRldirectory.org partsWarranty-1 2 years on compressor, 6 years on (Some limitations ,pp •d warranty for d- i � f � ! i r , `•1/i& 1 Alo, i i .il�- .�r� �� ���; i ' � , .d d't� � F �. .. e ^�� .,+ �\ w �' „!�_` as �� y y ' I .. ,w' ..S 15. h I1