HomeMy WebLinkAbout51644-Z ~O�tof SOplyo`p Town of Southold
* P.O. Box 1179
roc 53095 Main Rd
Southold, New York 11971
CERTIFICATE OF OCCUPANCY
No: 46935 Date: 03/27/2026
THIS CERTIFIES that the building SOLAR PANEL
Location of Property: 665 Moose Trail Cutchogue, NY 11935
Sec/Block/Lot: 103.-4-47
Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 12/23/2024
Pursuant to which Building Permit No. 51644 and dated: 02/13/2025
Was issued, and conforms to all of the requirements of the applicable provisions of the law.
The occupancy for which this certificate is issued is:
Roof-mounted solar panels to existing single-family dwelling as applied for.
The certificate is issued to: Matthew Sirico ,Allison Sirico
Of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL:
ELECTRICAL CERTIFICATE: 51644 3/23/2026
PLUMBERS CERTIFICATION:
Au o ' ed i ture
Ao��OfSOUIy�IG TOWN OF SOUTHOLD
BUILDING DEPARTMENT
' TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 51644 Date: 02/13/2025
Permission is hereby granted to:
Matthew J Sirico
665 Moose Trl
Cutchogue, NY 11935
To:
install roof-mounted solar panels to existing single-family dwelling as applied for.
Premises Located at:
665 Moose Trail, Cutchogue, NY 11935
SCTM# 103.-4-47
Pursuant to application dated 12/23/2024 and approved by the Building Inspector.
To expire on 02/13/2027.
Contractors:
Required Inspections:
Fees:
SOLAR PANELS $100.00
ELECTRIC -Residential $125.00
-RESIDENTIAL $100.00
Total $325.00
-- — ------------------
Building Inspector
*pF SO(/Tgolo
Town Hall Annex Telephone(631) 765-1802
54375 Main Road N
P.O.Box 1179 iQ
Southold,New York 11971-0959 �li`100um,�
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICAL COMPLIANCE
SITE LOCATION
Issued To: Matthew J Siricio
Address: 665 Moose Trail city: Cutchogue st: NY zip: 11935
Building Permit#: 51644 Section: 103 Block: 4 Lot: 47
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Electrician: Sunation License No: 33412ME
SITE DETAILS
Office Use Only
Commercial Indoor X Basement Service Solar X
Residential X Outdoor X 1st Floor Pool Battery Storage
As-built Renovation 2nd Floor Hot Tub EV Charger
New X Addition Attic Spa Generator
Surveyl IMezzanine Garage Dock17
INVENTORY
Service 1 ph In-wall Heater Recpt Ceiling Fixtures Smoke Detectors Pump
Service 3 ph Hot Water GFCI Recpt Wall Fixtures CO Detectors Heater
Main Panel A/C Condenser Single Recpt RecessdFixtures Combo Smoke/CO Transformer
Sub Panel A/C Blower Range Recpt Ceiling Fan Heat Detectors Salt Gen
Transfer Switch Mini Split Dryer Recpt UC Lights Fridge AutoCover
ARC Blower Heads Switches Pucks Lights Dishwasher Mini Fridge
GFI SepticDisconnect Emrgency Strobe 4'LED Microwave Garbage Disp.
ARC/GFI ERV Exit Lights Bath Exhaust Hood Dehumidifier
Other Equipment: 12.6kW Roof Mounted PV Solar Energy System w/(30)REC420AAPure2 Modules,
80A Disconnect, 80A Combiner Panel w/ (3)Strings to Roof, Lineside Tapped in Main
Notes: Solar
Date: 3/23/26
Inspector Signature:
o�apf SOUTyOI
� o
# TOWN OF SOUTHOLD BUILDING DEPT.
631-765-1802
INSPECTION
[ ] FOUNDATION 1 ST/ REBAR [ZIR UGH PLBG.
] FOUNDATION 2ND [ ULATION/CAULKING
FRAMING / STRAPPING [ AL 540orvoo,
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] -FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] .PRE C/O [ ] RENTAL
REMARKS:
DATE INSPECTOR
O�aOF SOUTyO� v coo SG [I aC•�` ----
# TOWN OF SOUTHOLD BUILDING DEPT.
'roorm��'' 631-765-1802
INSPECTION .
[ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG.
[ '] -FOUNDATION 2ND [ ] INSULATION/CAULKING
[ ] FRAMING /STRAPPING [ ] .FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL
REMARKS: Z 0 l Ct
DATE ` 9.18 9-, INSPECTOR
Of SOUTyO ---
N TOWN OF SOUTHOLD BUILDING DEPT.
"�a +N 631-765-1802
FNSPECTION '
[ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING
[ ] FRAMING /STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [. ] FIRE RESISTANT.PENETRATION
[ ] ELECTRICAL (ROUGH) [X] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ]' PRE C/O [ ] RENTAL
REMARKS:V.4&\l o0c, :6&k io
dot rlafn_e i -�
nj IM C, C��It, CA, Wj et4c+ of
��- qb
rilea 0
,e tk ����-
�Ot' wiev vac. l oce din, opt
DATE 7 a a� INSPECTOR
o�aOF SOUTyOI _ - - �Ir�
TO l
* # �FIOUTHOLD BUILD NG DEPT.
coo 631-765-1802
INSPECTION
[ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING
[ ] FRAMING /STRAPPING [ ] .FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) LECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL
REMARKS.
DATE �7 Z INSPECTOR
,�UP1 2 l 2025
tet
Graham CO11SU1 ing CO1'p 256-A Oi•iiioco Di•ive, Be•irht.ivateiis;'N_S1sl1718_
Building Consultants&Expeditors (631)665-9619 Fax(631)969-0115
April 18, 2025
Town of Southold
Post Installation Certification
Permit# BP51644
Sirico Residence - 665 Moose Trail, Cutchogue, NY 11935
Installation Date: 4/15/2025
Inspection Date: 4/17/2025
To Whom It May Concern,
The roof mounted photovoltaic system at the above referenced residence has
been generally observed to be installed properly in accordance with the
approved plans and is certified by Michael K. Dunn, PE, to be in compliance
with the minimum requirements,of the Town, the 2020 Residential Code of
New York State, 2018 International Residential Code (2018 IRC), Long
Island Unified Solar Permit Imitative (LIUSPI), and National Electric Code
2017, and the provisions of ASCE 7-16.
If you have any fiirther questions, do not hesitate to call.
Sincerely,
O
CO
RA
STAT�-
MELD INSPECTION REPORT DATE COMMENTS
IOUNDATION (IST) ------._..--.__ - ----- ----- - ---------
FOUNDATION (2ND)
z
ROUGH FRAMING & --- - ---- - - �
PLUMBING
r
INSULATION PER N. Y. ------ t�
STATE ENERGY CODE
iL
FINAL - - -- -- -----
ADDITIONAL COMMENTS v J
•� w
�tbj_� s
CA Qo
x
_......... - --- ------ - ------------ - ---------- '�
b
��o�gtlFFOIK�oGy� TOWN OF SOUTHOLD—BUILDING DEPARTMENT
Town Hall Annex 54375 Main Road P. 0.Box 1179 Southold,NY 11971-0959
Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov-
Date Received
APPLICATION FOR BUILDING PERMIT
For Office Use Only L- D'Ll 2 3 2024
PERMIT NO. Building Inspector: C Z 3 Z02�
Applications and forms must be filled out in their entirety.'Incomplete
applications will not be accepted. Where the Applicant is not the owner,an
Owner's Authorization form(Page 2)shall be completed.
Date: �a I
OWNER(S)OF PROPERTY:
Name:Matthew Sirico SCTM#1000-103-4-47
Proj r.ect 11 Address.665 Moose Trail, Cutchogue, NY 11935
Phone#:631-834-8172 Email mat.sirico@gmail..com
Mailing Address:665 Moose Trail_, Cutchogue, NY 11935
CONTACT PERSON'
Name: Evelyn Polvere/Sunation_Solar Systems
Mailing Address: 171 Remington Blvd., Ronkonkoma, NY 11779
Phone#. Y631-750-9454 ext 346 Email ermittin sunation corn
-DESIGN PROFESSIONAL INFORMATION:
Name:Michael,Dunn, Graham and-Associates Inc.
Mailing Address:256A Orinoco Drive, Brightwaters, NY 11718
Phone#:631-665-9120 Email:glenn@grahamassociatesny.com
CONTRACTOR INFORMATION:
Name:Scott Maskin/Sunation Solar Systems
Mailing Address:171 Remington Blvd., Ronkonkoma, NY 11779
Phone#: 631-750-9454 Email:pprmitting@§qpption.com
DESCRIPTION OF PROPOSED CONSTRUCTION
❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project:
❑Other
Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes BNo
1
PROPERTY INFORMATION
Existing use of property:Residential Intended use of property: Residential
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
this property? ❑Yes ®No IF YES,PROVIDE A COPY.
❑ Check Box After Reading: The owner/contractor/design professional is responsible for'all drainage and storm water issues as provided by
Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are
punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law.
Application Submitted By(print name): ott Maskin I]Authorized Agent ❑Owner
Signature of Applicant: Date:
STATE OF NEW YORK)
SS:
COUNTY OF Suffolk )
Scott Maskin being duly sworn,deposes and says that(s)he is the applicant
(Name of individual signing contract)above named,
(S)he is the Contractor
(Contractor,Agent,Corporate Officer,etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief;and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
day of ,20.2
Notary Public
LYNN VITA
Notary Public, State of New York
Registration #01V15068399
PROPERTY OWNER AUTHORIZATION Qualified in Suffolk County
(Where the applicant is not the owner) My Commission Expires Oct. 28,20
Matthew Sirico residing at 665 Moose Trail
CUtchogUe do hereby authorize Scott Maskin to apply on
my behalf the Town f Southold Building Department for approval as described herein.
7/� c Q G
Owner's Signature If Da e
Matthew Sirico
Print Owner's Name
2
w'�IA'.'nl4r;yy_
, SUEE UY�EO BUILDING DEPARTMENT-Electrical Inspector
TOWN OF SOUTHOLD
4
o Town Hall Annex - 54375 Main Road - PO Box 1179
W- r" .1 Southold, New York 11971-0959
Telephone (631) 765-1802 - FAX (631) 765-9502
roQerrO-southoldtownny.gov seandtc7i southoldtownny.-gov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All Information Required) Date:
Company Name: SUNation Solar Systems, Inc
Name: Scott Maskin
License No.: 33412-ME email: permitting@sunation.com
Address:_ 171 Remington Blvd. Ronkonkoma NY 11779
Phone No.: 631-750-9454
JOB SITE INFORMATION (All Information Required)
Name: Matthew Sirico
Address: 665 Moose..Trail Cutcho ue NY_ 11935
Cross Street:
Phone No.: 631-834-8172
Bldg.Permit#: j email: mat.sirico@gmail.com
Tax Map District: 1000 S _ction: 103 Block: 4 Lot: 47
BRIEF DESCRIPTION OF WORK (Please Print Clearly)
Installation of solar panels - flat on roof
Circle All That Apply:
Is job ready for inspection?: YES / NO Rough In Final
Do you need a Temp Certificate?: YES / NO Issued On
Temp Information: (All information required)
Service Size 1 Ph 3 Ph Size: _A #Meters Old Meter#
New Service- Fire Reconnect- Flood Reconnect-Service Reconnected - Underground - Overhead
#Underground Laterals 1 2 H Frame Pole Work done on Service? Y N
Additional Information:
PAYMENT DUE WITH APPLICATION
Request for Inspection Formals
CO BUILDING DEPARTMENT- Electrical tp'spector 5 2025
Gym TOWN OF SOUTHOLD
Town Hall Annex - 54375 Main Road - O,Box 1179 evnent
o Southold, New York 1 1 971-0959 ;e�tti 4d
4f4 O� Telephone (631) 765-1802 - FAX (631) 765-9�502:�"''°
rogerr@southoldtownny.gov - seand(a-southoldtownny.gov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All Information Required) Date: 6/19/25
Company Name: Sunation Solar Systems, Inc.
Electrician's Name: Scott Maskin
License No.: 33412-ME Elec. email:closeout@sunation.com
Elec. Phone No: 631-750-9454 ❑✓ I request an email copy of Certificate of Compliance
Elec. Address.: 171 Remington Blvd., Ronkonkoma, NY 11779
JOB SITE INFORMATION (All Information Required)
Name: Matthew Sirico
Address-665 Moose Trail, Cutcho ue, NY 11935
Cross Street- Little Neck Rd
Phone No.: 631-834-8172
Bldg.Permit#: BP51644 email: matt.sirico@gmail.com
Tax Map District: 1000 Section-.103 Block-. 4 LotA
BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
Square Footage:
Circle All That Apply:
Is job ready for inspection?: YES ❑ NO -]Rough In ❑ Final
Do you need a Temp Certificate?: 0 YES ❑ NO Issued On
Temp Information: (All information required)
Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter#
❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead
# Underground Laterals 1 2 H Frame 0 Pole Work done on Service? Y DN
Additional Information:
PAYMENT DUE WITH APPLICATION
INVE qUG f l EUq
Tesla DC Series String w/7esla Mid-Circuit Interrupters)"MCI"(typ.) TEGLA-MODEL 1538006n-y 12AOVf O ^
INVERTER-UNGROUNDED WITH 20`J5
sr
INTEGRAL DC ISOLATOR smc" _
TESLA 12DR40 VAC,1-0HASE RI(ty O "a
r INVERTER MAX32AMP (�A
Ted.MCF2(lypjl 1. �.i I 'V'
Module Feoz lNp Q'�'r
d SUNATI®N
Dc srwluG n
'-�"f� ld'� EAtE(:GY
W MRAi6(HP) DL—ING n `�Sl SIDE COw>GCTpN SUNabon SDlar Systems
EGG AXa40etl TO p.) EGC OC AC 171 Remington Blvd.
WPUT OUTPUT
Ronkonkoma,New Vork 17779
G 80A \ 200A \ (631)-760-9454
1 2 3 DC SIRING MAIN J MAIN J
NYSERDA
ROOF ATTIC E1-TERIOR INVERTER NSTALLER 4355
CONDUIT AND CONDUCTOR SCHEDULE krvekil I ,rz NUMBER
TAG CONDUCTOR CONDUIT RUN JOB NUMBER
INVERTER 02 24679
TYPE GAUGE QUANTITY TYPE SIZE LENGTH TESLA-MODEL 153800Duy1240V1 O 4 V
MAIN
1 PVWIre 10 6 WA NIA 15, INVERTER-UNGROUNDED WITR
INTEGRAL DC ISOLATORS WITCH
EGG 6 2 WA NIA 15, Ule24D VAc,1-PHASE
2 MC Cable 10 6 WA NIA 20' MAX 32 AMP (D c2i A
EGG 6 2 WA NIA 20' 1//f G G GMAIN3 THWN-2 10 6 EMT 1.50" 25' —— ] (Ppy)PANEtRVICEEGC 6 2 EMT 1.50' 25' I« PHOTOVOI-TAIC DISCONNECT P--
SERVICE MTED SERVICE MTEO SERVICE RATED
4 THWN-2 8 6 PVC SCH.80 1.25" 15' DC STRING 41 ENCLOSURE IS ENLLD$IIRE ENCLOSURE
EGG 10 2 PVC SCH.80 1.00" 15' RATED-00A 5 MIGO AD N.1— 6 NIN.100A 7
EGG INPUT OUTPUT MAIN-10k AN: MIN.Yak AIC MW.22k AIC
S THWN-2 4 3 CARFLEX 1.50" 10' —
IOR
EGG 8 1 CARFLEX 1.50" 10, G DISLON ECTING MEANS GROUNDING l'N
6 THAN-2 4 3 CARFLEX 1.50" 10, 1 2 g Dc scTna aR 4 ELECTRODE r N
EGC 8 1 CARFLEX 1.50" 10, RCOF Amc EXTERIOR I )-
7 THAI 4 3 PVC SCH.80 1.50" 10, J Z
GEC 8 1 PVC SCH.80 1.50" 10, Z r
0 U 7
a a)) o
0 IV
U.z U cis
o= ❑
Circuit# PV Module Oty. Inverter Oty. Maximum AC Operating Current LU cis
rn Cn H
1 REC420AA Pure 2 11 0) m
Tesla Solar Inverter 7.6kW 1 32 A
2 REC420AA Pure 2 11
m
3 REC420AA Pure 2 B Tesla Solar Inverter 7.6kW 1 32 A m
co
Maximum AC Operating Current(Total) 64 A
E1 -1
ONE-LINE DIAGRAM
Graham Associates 256 Orinoco Drive, Suite A Brightwaters,NY 11718
Planning& Design (631)665-9619
December 19, 2024 '
Town of Southold
Building Department
54375 Rt. 25
Southold, NY 11971
Re: Sirico Residence
665 Moose Trail
Cutchogue, NY
Proposed 12.6 KW PV System
To Whom It May Concern,
Please be advised that I have analyzed the existing roof structure at the
above-mentioned premises and have determined that it is adequate to
support the additional load of the solar panels and a 140 mph wind load and
20 psf snow load-without overstress, in accordance with the following:
The 2020 New York State Uniform Fire Prevention and Residential Building
Code; Town of Southold Local Code, Long Island Unified Solar Permit
Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020
National Electric Code including ASCE7-16
If yo qq , rther questions, do not hesitate to call.
`P
IXyr b298�� -�0
OF 1�
Michael K Dunn, RA
SnapNrack@
Ultra Rail Roof Mount System
IM
-.�
;. .. .......
i
r�,f15
y,
M
The Ultimate Value in Rooftop Solar
• Industry leading Wire Mounts available for all
Management Solutions roof types
Aft All SnapNrack Module
Sin • - • • InstallatClampsion �i// iAccessories
arecompatible with
both railprofiles
Start Installing Ultra Rail Today
r
SnapNrack
snap-inA sleek, straightforward rail solution for mounting solar modules on all roof types. Ultra Rail now
features one rail profile, UR-45, a lightweight eafl profile that's suited for,all, geograph'ic regions,
with varying span capabilities. UR-45 Rail maintains all the great features of SnapNrack rail like
. . . . an open rail channel for integrated wire management. The Ultra Rail
portfolio features multiple roof attachment sealing technologies for all: install preferences.
NEW! UltraFoot Roof Attachments
• Features SpeedSealT"'+ Technology, a pre-installed butyl pad
for easy peel & stick installation _ -
• The only single lag roof attachment with butyl sealing available
• UltraFoot available in (3) configurations to accomodate rafter
& deck mounting based on DeckAnchorT" or wood screw install
preferences
• All UltraFoot designs feature new Flip Clamp Mount that
centers load over fastener & creates an easier snap-in
experience with UR-45 Rail
The Entire System is a Snap to Install
• Ultra Rail Mounts include snap-in brackets for
attaching rail
00 • Ultra Rail Mid Clamps & End Clamps are one-size-
fits-all universal clamping height
• Universal End Clamps & snap-in End Caps provide a
clean look to the array edge
Unparalleled Wire Management
• Open rail channel provides room for running wires
resulting in a long-lasting quality install
• Module clamps eliminate bolt interference in
the rail channel creating more space for wire
management
• Industry best wire management offering includes
Junction Boxes, Universal Wire Clamps, MLPE
Attachment Kits & Conduit Clamps
• System is fully bonded & listed to UL 2703
Standard
DESCRIPTION: DOC NUMBER:
SNAPNRACK, TDS, UR-45 RAIL SNR-DC-01420 5nn (apNr(aCk@
DRAWN BY:
PART NUMBER(S): H.WULFEKOETTER
SUNRUN INSTALLATION SERVICES INC.
232-10095, 232-10096, 232-10097, 232-10098, REV: DATE: 225 BUSH STREET,SUITE 1400.SAN FRANCISCO,CA 94104 USA
PHONE(B77)732-2860.CONTACT®SNAPNRACKCOM
MEINFORMATION IN MIS ORAWINO IS CONFIDENN AND PROPRIETARY.MY
UNITS: IN, LB, DEG [MM, KG, DEG] SHEET: 1:1 3/6/2024 REPROOUCT ON,DSC OSURNSENT FSUNRUF S PRO LLC.DWMOUTME
WS.-CONSENTO THIER-N SOIRN LLC.
UR-45 RAIL PROPERTIES
SKU FINISH RAIL LENGTH WEIGHT (lb)
232-10095 MILL 172 in 5.55
232-10096 BLACK 172 in 5.55
232-10097 MILL 94 in 3.03
232-10098 BLACK 94 in 3.03
.740
.895
SECTION PROPERTIES
A 0.319 in
Ixx 0.134 in .855
Iyy 0.121 in
Sx (TOP) 0.152 in3
Sx (BOT) 0.156 in3
Sy (LEFT) 0.164 in3
Sy (RIGHT) 0.164 in3
MATERIALS: 6005-T5 ALUMINUM
DESIGN LOAD (LBS): N/A
ULTIMATE LOAD (LBS): N/A
TORQUE SPECIFICATION: N/A FT-LBS
CERTIFICATION: UL 2703, FILE E359313
WEIGHT (LBS): 5.48 - 5.62 (172 in), 2.96 - 3.10 (94 in)
Solar Shutdown Device 1 Technical Specifications
The Solar Shutdown Device is a Mid-Circuit Interrupter(MCI)and is part of the PV system rapid shutdown (RSD)function in
accordance with Article 690 of the applicable NEC. When paired with Tesla Solar Inverter,solar array shutdown is initiated by any
loss of AC power.
Electrical Nominal Input DC Current Rating(IMP) 12 A
Specifications Maximum Input Short Circuit Current(I5C) 19 A
Maximum System Voltage(PVHCS) 600 V DC
RSD Module Maximum Number of Devices per String 5
Performance Control Power Line Excitation
Passive State Normally Open
Maximum Power Consumption 7 W
Warranty 25 years
Environmental Ambient Temperature -40°C to 50°C(-40°F to 122°F)
Specifications Storage Temperature -300C to 700C(-220F to 158°F)
Enclosure Rating NEMA 4X/IP65
Compliance Certifications UL 1741 PVRSE, UL 3741,
Information PVRSA(Photovoltaic Rapid Shutdown Array)
RSD Initiation Method PV System AC Breaker or Switch
Compatible Equipment See Compatibility Table below
Mechanical Model Number MCI-1
Specifications Electrical Connections MC4 Connector 250 mm
Housing Plastic
M4 Screw
Dimensions 125 mm x 150 mm x
22 mm 650 mm 150 mm M8 Bolt
(5inx6inxlin)
Weight 350 g (0.77 lb) Nail/
Wood Screw
Mounting Options ZEP Home Run Clip V
M4 Screw(#10)
-- -- ---- ----
M8 Bolt(5/16")
Nail/Wood screw
H 125 mm >►�
22 mm
UL 3741 PV Hazard Control (and PVRSA) Compatibility
Tesla Solar Roof and Tesla/Zep ZS Arrays using the following modules are certified to UL 3741 and UL 1741 PVRSA when installed
with Tesla Solar Inverter and Solar Shutdown Devices. See Tesla Solar Inverter Rapid Shutdown: Module Selection Based on PV
Hazard Control System Listing for guidance on installing Tesla Solar Inverter and Solar Shutdown Devices with other modules.
Brand Model Required Solar Shutdown Devices
Tesla Solar Roof V3 1 Solar Shutdown Device per 10 modules
Tesla Tesla TxxxS (where xxx=405 to 450 W, increments of 5) 1 Solar Shutdown Device per 3 modules 7
Tesla Tesla TxxxH (where xxx=395 to 415 W, increments of 5) 1 Solar Shutdown Device per 3 modules
Hanwha Q.PEAK DUO BLK-G5 or Q.PEAK DUO BLK-G6+ 1 Solar Shutdown Device per 3 modules
7 Exception:Tesla solar modules installed in locations where the max Voc for three modules at low design temperatures exceeds 165 V shall be
limited to two modules between Solar Shutdown Devices.
Tesla Solar Inverter and Solar Shutdown Device Datasheet 4
Tesla Solar Inverter Technical Specifications
Mechanical Specifications Dimensions 660 mm x 411 mm x 158 mm (26 in x 16 in x 6 in)
00
00
00
7 M L o0
00
00
00
00
00
•oo
660 00
mm o0
000
00
00
411 mm 0 �158
I I mm
Weight 52 Ib5
Mounting Options Wall mount(bracket)
5 Door and bracket can be removed for a mounting weight of 37 lb.
Environmental Specifications Operating Temperature -30oC to 450C(-220F to 1130F)6
Operating Humidity(RH) Up to 100%,condensing
Storage Temperature -30oC to 700C(-22°F to 158°F)
Maximum Elevation 3000 m(9843 ft)
Environment Indoor and outdoor rated
Enclosure Rating Type 3R
Ingress Rating IP55(Wiring compartment)
Pollution Rating PD2 for power electronics and terminal wiring
compartment, PD3 for all other components
Operating Noise @ 1 m <40 db(A) nominal, <50 db(A) maximum
6 For the 7.6 kW Tesla Solar Inverter,performance may be de-rated to 6.2 kW at 240 V or
5.37 kW at 208 V when operating at temperatures greater than 45°C.
Compliance Information Grid Certifications UL 1741, UL 1741 SA, UL 1741 SB, IEEE 1547-2018,
IEEE 1547.1
Safety Certifications UL 1741 PVRSS, UL 1699B, UL 1998(US), UL 3741
Emissions EN 61000-6-3(Residential), FCC 47CFR75.109(a)
Testa Solar Inverter and Solar Shutdown Device Datasheet 3
Tesla Solar Inverter Technical Specifications
Electrical Specifications: Model Number 1534000-xx-y 1538000-xx-y
Output (AQ Output(AC) 3.8 kW 7.6 kW
Nominal Power 3,800 W 7,600 W
Maximum Apparent Power 3,328 VA at 208 V 6,656 VA at 208 V
3,840 VA at 240 V 7,680 VA at 240 V
Maximum Continuous Current 16 A 32 A
Breaker(Overcurrent Protection) 20 A 40 A
Nominal Power Factor 1 -0.9(leading/lagging
THD(at Nominal Power) <5%
Electrical Specifications: MPPT 2 4
Input (DQ Input Connectors per MPPT 1-2 1-2-1-2
Maximum Input Voltage 600 VDC
DC Input Voltage Range 60-550 VDC
DC MPPT Voltage Range 60-480 VDC1
Maximum Current per MPPT(IMP) 13 Az
Maximum Short Circuit Current per 17 Az
MPPT(Isc)
Maximum current.
2 Where the DC input current exceeds an MPPT rating,jumpers can be used to allow a single MPPT to
intake additional DC current up to 26 A IMP/34 A Isc.
Performance Peak Efficiency 98%at 208 V 98.4%at 208 V
Specifications 98.1%at 240 V 98.6%at 240 V
CEC Efficiency 97.5%at 208 V 97.5%at 208 V
97.5%at 240 V 98.0%at 240 V
Allowable DC/AC Ratio 1.7
Customer Interface Tesla Mobile App
Internet Connectivity Wi-Fi (2.4 GHz,802.11 b/g/n),
Ethernet,,Cellular(LTE/4G)4
Factory-Installed Revenue Grade Meter Revenue Accurate(+/-0.5%)s
AC Remote Metering Support Wi-Fi (2.4 GHz,802.11 b/g/n), RS-485
Protections Integrated arc fault circuit
interrupter(AFCI), Rapid Shutdown
Supported Grid Types 60 Hz,240 V Split Phase
60 Hz,208 V Wye
3 Applicable to Tesla Solar Inverter with Site Controller(1538000-45-y)only.
4 Cellular connectivity subject to network operator service coverage and signal strength.
Tesla Solar Inverter and Solar Shutdown Device Datasheet 2
Testa Solar Inverter
with Solar Shutdown Device
Tesla Solar Inverter completes the Tesla home solar system, converting DC power from solar to AC power for home consumption.
Tesla's renowned expertise in power electronics has been combined with robust safety features and a simple installation process
to produce an outstanding solar inverter that is compatible with both Solar Roof and traditional solar panels. Once installed,
homeowners use the Tesla mobile app to manage their solar system and monitor energy consumption, resulting in a truly unique
ecosystem experience.
KEY FEATURES
• Built on Powerwall technology for 0.5%revenue-grade metering for Solar Renewable
exceptional efficiency and reliability Energy Credit(SREC) programs included
• Wi-Fi, Ethernet,and cellular connectivity 3.8 kW and 7.6 kW models available
with easy over-the-air updates
• Designed to integrate with Tesla Powerwall and Tesla App
T—9.L.,^
r
111
_
p$
o �m
E$ T
?'2 � w
{.' �s4� F T b.R# r 2 *�H'� ,�yyitK�✓w�t ;�`� � ti ,�'f?4�. s
4w ';
March 5,2023
RNIFURHARE C
PRODUCT SPECIREATION5
GENERAL DATA * . _ _
36.4 t0.1 18.5i0.1
Cell type: 132 half-cut REC heterojunction cells with lead-free, 6.os
gapless technology,6 strings of 22 cells in se ries
Glass: 0.12in solar glasswith anti-reflective surface treatment 492
in accordance with EN 12150
Backsheet: H igh ly resistant po lymer(b la ck) 0.24 t0.01
Frame: Anodized aluminum(black) s
A
Junction box: 3-part,3 bypass diodes,lead-free C31
s
IP68 rated,in accordancewith IEC 62790
M
Staubli MC4 PV-KBT4/KST4(12 AWG) 0.43 to.01
Connectors: inaccordancewith IEC 62852.IP68onlywhenconnected
Cable: 12 AWG solar cable,49.2+49.2 in 0.8 to.oz
in accordance with EN 50618 a9.z
cs
6.05
Dimensions: 73.4x 40.9 x 1.2 in(20.88 sq-ft) --
Weight: 47.6 lbs(21.6 kg) t-�1.8 0.9 27.3±0.1
Origin: Made in Singapore T l.z
Measurements in inches(mm] t
ELECTRICAL DATA Product Code':RECxxxAA PURE 2 CERTIFICATIONS
_--- ...._ _ ' ._ _ --__-. _ _ _ ._ 1 i-______�_
Power Output-PMAx(Wp) 400 410 420 430 IEC 61215:2016,IEC 61730:2016,UL 61730
Watt Class Sorting-(W) 0/+10 0/+10 0/+10 0/+10 IEC62804 PID
IEC61701 Salt Mist
Nominal PowerVoltage-VM,,(V) 41.1 41.6 42.2 42.8 IEC62716 Ammonia Resistance
u Nominal Power Current-IMPP(A) 9.74 9.86 9.96 10.05 UL61730 Fire Type 2
Open Circuit Voltage-Voc(V) 48.5 48.8 49.1 49.3 IEC62782 Dynamic Mechanical Load
IEC 61215-2:2016 Hailstone(35mm)
Short Circuit Current Isc(A) 10.60 10.67 10.74 10.81 IEC62321 Lead-freeacc.to ROHS EU 863/201S
Power Density(W/ft2) 19.2 19.6 20.1 20.6 ISO 14001,I50 9001,IEC 45001,IEC 62941
Panel Efficiency(%) 20.6 21.1 21.7 22.2
Power Output-PMAx(Wp) 304 312 320 327 oVE �mOe
Lead-Free
Nominal Power Voltage-VMPP(V) 38.7 39.2 39.8 40.3 -`- `-" -- -- --
TEMPERATURE RATINGS'
i- e_ -_ ---
Nominal Power Current IMP,(A) 7.86 7.96 8.05 8.12 Nominal Module Operating Temperature: 44°C(±2°C)
Z Open Circuit Voltage-Voc(V) 45.7 45.8 46.0 46.2 Temperature coefficient OfPMAx: -0.24%/°C t
Short Circuit Current-Isc(A) 8.50 8.62 8.68 8.73 Temperature coefficient ofVoc: -0.24%/°C a
Values at standard test conditions(STC air mass AM1.5,irradiance 10.75W/sgft0000W/m2),temperature 77°F(25'C),based ona production spread Temperature coefficient oflsc: 0.04%/°C
with a tolerance of P.,Voc&Isc t3%within one watt class.Nominal module operating temperature(NMOT:air mass AM 1.5,irradiance 800 W/m2,
temperature687(20'C),windspeed3.3ft/s(lm/s).*Where xxx indicates the nominal power class(P.)atSTCabove. 'The temperature coefficients stated are linear values �
MAXIMUM RATINGS J 'WARRANTY_ J DELIVERY_I_N_FORMATION
Operational temperature: -40...+8S°C Standard REC ProTrust Pa nets pe r pal let: 33 0
System voltage: 1000V Installed byan REC No Yes Yes Panels per40ftGP/high cube container: 792(24 pallets) -
Certified Solar Professional
Test toad(f ront): +7000Pa(1461bs/ftz)' System Size All 425kW25500kW Panels per 53 ft truck: 858(26 pallets)
Test load(rear): -4000Pa(83.51bs/ftz)' Product Warranty(yrs) 20 25 25
Series fuse rating: 2SA Power Warranty(yrs) 25 25 25 SLOW LIGHT BEHAVIOUR _ m
Reverse current: 25A Labor Warranty(yrs) 0 25 10 Typical low irradiance performance of module atSTC:
'Seeinstallation manual for mounting instructions. Power in Year 1 98% 98% 98% o
Design load=Test load/1.5(safety factor) o a o
Annual Degradation 0.25% 0.25% 0.25% v °-- ----------=--------- a
Power in Year 25 92% 92% 92% -------+-------------------- --------- a
See warranty documents for details.Conditions apply d .--------"------------------' o
¢ a
Availablefrom: m �Irradiance(W/m') m
Founded in 1996,REC Grou p is an internationa I pioneering solar energy company dedicated to empowering consumers REC Solar PTE.LTD. ��
with clean,affordable solar power.As Solar's Most Trusted,REC is committed to high quality,innovation,and a low 20Tuas South Ave.14 J R
carbon footprint in the solar materials and solar panels it manufactures.Headquartered in Norway with operational Singapore 637312 �
headquarters in Singapore,REC also has regional hubs in North America,Europe,and Asia-Pacific. post@recgroup.com
www.recgroup.com
MEL
V4
�. SOLAR'S MOST TRUSTED
RED
'Ok
o.
:J
3:
z?
� 4
'r
.;{ COMPACT PANEL SIZE
4. EXPERIENCE
430 WP REIE
����////� 25 YEAR
20.6 PRoTRUST
FTz WARRANTY
22.2%*EFFICIENCY LEAD-FREE
ELIGIBLE ROHS COMPLIANT PERFORMANCE
-�_ PLAN KEY ®Q UTILITY METER
4 -SERVICEDISCONNECT PROPOSED RESIDENTIAL
-d° 1. COVER SHEET IN-SUPPLY SIDE CONNECTION (ExT)
Al-1 PARTIAL ROOF PLAN O-AUTOMATIC TRANSFER SWITCH PHOTOVOLTAI C S YSTEM
D
Al-4 ROOF ACCESS PLAN ®'GAS METER
S1-1 STRUCTURE ®-MAIN SERVICE PANEL
E1-1 ONE-LINE DIAGRAM M_-SUB WIRrLEPANEL 171 RE INSOLARSYSTEMS INSTERDA
ALLER
4355
®-WIRELESS ROUTER 171 REMINGTON BOULEVARD INSTALLER
E2-1 PV LABELS RONKONKOMA,NEW YORK 11779 NUMBER
®-INVERTER ACCESS
G1-1 PV PHOTOS
®. ROOF
-ENPHASE IQ COMBINER
- Sirico Residence
-PANEL PHOTOVOLTAIC
- 665 Moose Trail, Cutchogue, NY 11935
Q ELECTRIC
9-ENPHASE ENVOY
®-SENSE CONSUMPTIONMONITOR -18"-VENTILATION (EXT) Drawn By: M. Danziger- 12/18/2024
-18"-VENTILATION
-AC DISCONNECT - - -
\5-
(]-TESLA GATEWAY
(8)PROPOSED PV MODULES �eFtE,D.q/�,
®-TESLAPOWERWALL
M9-ENPHASE IG SYSTEM CONTROLLER �+ ``pEL �� �A
®-ENPHASE IG LOAD CONTROLLER XAA
i r,
0-ENPHASE IG 10 BATTERY
®-ENPHASE IQ 3 BATTERY _4'
US-GENERATION PANEL
®-BACKED UP LOADS CENTER (G) SUB PPV INV INV I/�
® -VENTPIPE - APP D ED AS NOTED �'� °29, AI
/`�)
..n-EXTERIOR LOCATION ACCESS 1
ACES -rr :.PEa HESERI'ED F7ri P.t
^+-1ST FLOOR LOCATION 8� Buil TTI� e
-BASEMENT LOCATION (B) SS Mjgp /-y/ Town buildingexaminer has received the enclosed document for minimum acceptable
- -GARAGE LOCATION �- ris d BY plan submittl requirements of the town as specified in the building and/or Residential
Code of the State of New York. This review does not guarantee compliance with that
NOTIFY BUILDING DEPARTMENT AT code. that responsibility is guaranteed under the seal and signature of the New York
PROPOSED PV SYSTEM 1B"-VENTILATION 631765-1802 8AM TO 4PM FOR THE State licensed design professional of record. That seal and signature has been
18 VENTILATION interpreted as an attestation that,to the best of the licensee's belief and information
,, ,; .; FOLLOWING INSPECTIONS: the work in this document is:
Module Type/Oty: (30)REC420AA Pure 2 FO Accurate
1. FOUNDATION-TWO REOI IIRFD . Conforms with governing codes applicable at the time of submission
Module Dimension: 73.4"x 40.9"x 1.211 FOR POURED CONCRETE- 0 Conforms with reasonable standards of practice and with view to the
Module Weight/PSF: 47.6 Ibs/2.27969348659004 PSF 2. ROUGH-FRAMING&PL II�,1.;,:%. a safeguarding of life,health,property and public welfare is the responsibility of the
licensee.
Inverter: (2)Tesla Solar Inverter 7.6kWV77-vvvvvvvv & INSULATION
System DC Rating: 12.6 kW 4. FINAL-CONSTRUCTION MUST Structural Statement
System AC Rating: 15.36 kW/AC BE COMPLETE FOR C.O. 0 The existing structure is adequate to support the new loads imposed by the
All CONSTRUCTION SHALL MEET THE photovoltaic module system including uplift and shear. The existing rafter sizes
Aurora Estimated AC Production: 17,822 kWh/yr
REQUIREMENTS OF THE CODES OF NEW and dimensions conform to RC-NYS 2020 table R802.4.1(2)-Rafter Spans.
(22)PROPOSED PV MODULES YORK STATE NOT RESPONSIBLE FOR
tLT PV Notes
.� FRONT OF HOUSE-FACING STREET OR DRIVEWAY 1. This PV system has been designed to meet all current and applicable fire
NEW YORK STATE &TOWN CODES prevention setback pathways per 2020 NYS Residential Code. Proper ground
clearance,roof access points,access pathways and ventilation systems shall be
A S REQUIRED-AND-EONDITIONS-O provided where necessary. An in depth description of each applicable code
AREA RESERVED FOR AHJ: � � ZBA reference and exception for any codes is depicted on the PV-1 plate of this
drawing package.
2. Roof shall have no more than a single layer of roof covering in addition to the
SOUTNO TOWN PLANNING BOARD solar equipment.
'rTu 3. Installation of solar equipment shall be flush-mounted,parallel to and no more
N T n TOWN TRUSTEES than 6-inches above the surface of the roof.
4. Weight of the installed system shall not exceed more than 5-psf
N.Y.S. EC 5. Any plumbing vents are not to be cut or covered for solar equipment installation.
Any relocation or modification of the vent requires a plumbing permit and
X N R n inspection.
FULL HOUSE ROOF PLAN SV on
wo
SCALE:N.T.S. D This PV system has been designed to meet the minimum design standard for building
and other structures of the ASCE 7-16 and the 2020 New York State Residential
Code.
PV1
JOB# 24679 OCCUPANCY OR
COVER PAGE USE IS UNLAWFUL
REVISION # N/A WITHOUT CERTIFICAT
SUNATION OF OCCUPleaiNCY
ENERGY REVISED BY N/A ELECTRICAL
INSPECTION REQUIRED
• ROOF 2 32'-10y2' r\S-T E O�$�
RIDGE V
ki G�1AE � C
2
n
U iy
x o �� O2oS 17
a�2 MCI M I O��Y � '4
re @
0
15'-2y2"
V
17'-5"
d OSUNATION
ENERGY
PHOTOVOLTAIC MODULE MF
SUNation Solar Systems
171 Remington Blvd.
(TYP.) Ronkonkoma,New York 11779
(631)-750-9454
ROOF AREA INVERTER #2
STRING 3 IN SALLE R 4355
1OOF 1 INVERTER #1 NUMBER
STRING 1 RIDGE
GUTTER JOB NUMBER
TYP
2,-4y2, r 3 &y ri w, :` y . a ( ) 24679
w' o- ,
n
v
05 MCI M 1 M I M 1
N O
1T-2" Ud " r r r �� h p +. £ 6�v a r O
[[ ",.dr,."' w c F aa a"n ',,4ry4ry m'. & rc A h r *.4+. '"�" y :' N
Q _ '>G'� f�: bfi z#* ` ,• ,rf°ii..�." 4F. f =„tY .Y;"S., C�
i
m
MCI M 1 M I M c
I 0 lLU m
Z 0 ❑
N o m
o c
CD
C O
INVERTER #1 `°
STRING 2 GUTTER
42'-10Y2'
Attachment Spacing: Portrait Attachment Spacing: Landscape
Roof# Roof Description Modules Azimuth Tilt Pitch
Interior Edge Corner Interior Edge Corner
1 FOH South Roof 22 1670 300
8/12 4811 3211 1611 6411 4811 6411 /�►
2 FOH South Roof 8 1670 300 8/12 48" 32" 16" 64" 48" 64" 3/16" =1'-0"
Al = 1
PARTIAL ROOF PLAN
SOLAR ENERGY SYSTEMS
SST R�o
INY) R324.6 Roof access and pathways. Roof access, pathways and G
setback requirements shall be provided in accordance with Sections !t� UGH E�/f
R324.61 through R324.6.2.1. Access and minimum spacing shall be QG
required to provide emergency access to the roof,to provide pathways nt
to specific areas of the roof, provide for smoke ventilation opportunity Ex '< t�
areas and to provide emergency egress from the roof. (Ac —4 1
Exceptions: c 7� /
O
p �O 2981
1. Detached, non-habitable structures, including but not limited to 0
detached garages, parking shade structures, carports, solar NE Y
trellises and similar structures, shall not be required to provide
roof access.
2. Roof access, pathways and setbacks need to be provided Access
where the building official has determined that rooftop ROOF
operations will not be employed.
3. These requirements shall not apply to roofs with slopes of two SUNATION
units vertical in 12 units horizontal(17-percent slope)or less ENERGY
[NY] R324.6.1 Pathways. Not fewer than two pathways, on separate _ SUNation Solar Systems
roof planes from lowest roof edge to ridge and not less than 36 inches 18"-VENTILATION (ExT 171 Remington Blvd.
914 mm wide, shall be provided on all buildings. Not fewer than one Ronkonkoma,New York 11779
( ) p 9 -18"-VENTILATION (631)-750-9454
pathway shall be provided on the street or driveway side of the roof.
For each roof plane with a photovoltaic array, a pathway not less than
36 inches (914 mm)wide shall be provided from the lowest roof edge (8)PROPOSED PV MODULES _ N/V VV NYSERDA 4355
INSTALLER
to the ridge on the same roof plane as the photovoltaic array, on an NUMBER
adjacent roof plane, or straddling the same and adjacent roof planes.
Pathways shall be over areas capable of supporting fire fighters JOB NUMBER
accessing the roof. Pathways shall be located in areas with minimalVV
obstructions such as vent pipes, conduit, or mechanical equipment. /�
Pathways on opposing roof slopes shall not be located along the same 24679 9
plane as the truss, rafter, or other such framing system that supports
the pathway.
Exception: (G) SU8 PPV INV INV
1. Access pathways shall not be required on roof slopes containing Ln
photovoltaic modules, panels, or an array where the opposing ACCESS co N
or adjacent roof slope is an access roof. ROOF N
O z Co
Access Roof-A roof surface that: (B) S rv�sP F N
� m r
1. Can be accessed from the ground by the fire service. Q) 0 m
2. Is capable of providing fire service access to the ridge or peak p r N
of an opposing or adjacent roof surface that contains 18"-VENTILATION Z o v co
photovoltaic modules,panels,or an array. — 'm
18"-VENTILATION W n` '-
3. Is relatively free of vents,skylights,conduits, mechanical I-- rW
equipment and other such obstructions. v) m
a
vvvvvvvvvvv 2
0
4. Does not contain photovoltaic modules, panels or an array,or is 0 ro
a single ridge roof where the maximum edge to edge width of m o
the photovoltaic panel system does not exceed 33 percent of
the ridge length.
[NY] R324.6.2 - Setback at ridge. Photovoltaic arrays shall not be vvvvvvvvvvv
located less than 18 inches(457 mm)from a horizontal ridge.
[NY] R324.6.2.2 - Emergency escape and rescue opening. Panels
and modules installed on dwellings shall not be placed on the portion
of the roof that is below and emergency escape and rescue opening.
A pathway not less than 36 inches(914 mm)wide shall be provided to w .
the emergency escape and rescue opening. (22)PROPOSED PV MODULES
FRONT OF HOUSE-FACING STREET OR DRIVEWAY N.T.S.
A1 =4
ROOF ACCESS PLAN
GASTER�,�
Typical Attachment Method �� HAFT°" 0g.
CD m
n
SNAP'N'RACK ULTRA RAIL
1
0
RIDGE RIDGE A/ y0�
PHOTOVOLTAIC 171-811 PHOTOVOLTAIC 17'-11" SNAP'N'RACK SPEEDSEAL
MODULE MODULE L-FOOT
RAIL 3/4"MODULE SPACING 3/4"MODULE SPACING INSTALLERS TO APPLY SEALANT ON
BETWEEN ROWS AND BETWEEN ROWS AND BOTTOM SEALANT RING SUN/�TION
COLUMNS(TYP.) COLUMNS(TYP.) USE-NPC Solar Seal#900 SHING ELAYER COMPOSITE
ENERGY
SUNation Solar Systems
RAFTER RAIL (1)5/16"X5"m 171 Remington Blvd.
2"X 4"/16"O.C. SEALING LAG SCREW / Ronkonkoma,New York 11779
FASTENED TO RAFTER / / (631)-750-9454
RAFTER /
PERLIN INSTALLER
4355
2"X 10"/16"O.C. / � / INSTALLER
/ NUMBER
PLYWOOD DECKING JOB NUMBER
(TYP.)
WOOD FRAMING 24679
EXTERIOR SOFFIT SOFFIT (TYP-)
WALL
EXTERIOR
WALL ATTACHMENT TYPE APPLIED TO-ROOF"TYP"
13'-7.5" 13'-10"
ROOF SECTION (TYP.) - ROOF"1" ROOF SECTION (TYP.) - ROOF"2"
SCALE: N.T.S. SCALE: N.T.S.
LO
m It
N
T Q
r N
Oo
Z
SOLAR MODULE FRAME Q T
NOTE:3/4"SPACING 2 I
AND COLUMNS.BETWEEN ULE ROWS Q .0
Roof# Rafter Size/Spacing Max Span Material Layers Sheathing N
r� °° 00O°°�� END CLAMP Q 0
1 2"x 4" /16" O.C. 13'-7.5" Composite Shingles 1 Oriented Strand Board . �O°°O OOP .Q° O. j a s„ (TYP) ILL U �
0 0000 000° o
OOO°O°• Q°°°"�j�C� HEIGHT ADJUSTABLE 0 —
2 2"x 10"/16" O.C. "IT-10" Composite Shingles 1 Plywood . oO ,rOO OO•
i _ L-FOOT(TYP.) � •L •M C
0 �
SNAP'N'RACK U) m
® e o a o f ULTRA RAIL O O
(TYP.) O
co
• •o°o° o°o° °o°o°°o°a°'
aoo 0 000 o Oho°o ooQ�o 5.5" LO HEIGHT OFF C Ln
SURFACE ROOF Q
CO
�'.pd O�O�O r0�40 O�QOO (0
OLATRIM'ST-550'PEST AND
Typical Module DEBRIS ARRIER-CUTAWAY
Side Profile FOR CLARITY.
CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA - TABLE R301.2(1)
WIND DESIGN SUBJECT TO DAMAGE ICE BARRIER
SEISMIC DESIGN WINTER DESIGN MEAN ANNUAL
GROUND SNOW
UNDERLAYMENT FLOOD HAZARD AIR FREEZING INDEX -
TEMPERATURE
SPEED(MPH.) TOPOGRAPHIC WIND BORNE DEBRIS CATEGORY TEMPERATURE
SPECIAL WIND ZONE WEATHERING FROST LINE DEPTH TERMITE
LOAD EFFECTS ZONE REQUIRED
S 1
20 PSF 140 B YES 2 B SEVERE 3'-0" MODERATE TO 15 DEG N/A SEE PLANS 599 51
HEAVY EXAMINER STRUCTURE
�GXS E1�F0
co o .
z rn
e z 0
O
INVERTER#1 UTILI
w/Tesla Mid-Circuit Interrupter(s)"MCI" t TESLA-MODEL 1538000-xx-y[240V) SERVICE
Tesla DC Series String tefS P yp.� INVERTER-UNGROUNDED WITH O `
INTEGRAL DC ISOLATOR SWITCH c�` Y O�
TESLA 120/240 VAC,1-PHASE Heisting
+ O eoc INVERTER MAX 32 AMP PSEG Utility Meter w A
Account N-9624080051 I`V,'
+ 0501745
Tesla MCI-2(typ.) +ve/
Meter# 6201240vModule J-Box(typ.i SUNATI®N
ENERGY
. . . . . C�J
DC STRING#1
PV Module(typ.) 11 0
DC STRING#2 SUPPLY SIDE CONNECTION SUNation Solar Systems
EGC Attached To Rail(typ.) DC AC 171 Remington Blvd.
EGC INPUT OUTPUT Ronkonkoma,New York 11779
(631)-750-9454
G 80A 1 200A
1 2 3 DCSTRING MAIN J MAIN INNYSERDA
ALLE 4355
INVERTER INSTALLER
ROOF ATTIC EXTERIOR NUMBER
2P40A 2P40A
CONDUIT AND CONDUCTOR SCHEDULE Inverter#1 Inverter#2
JOB NUMBER
TAG CONDUCTOR CONDUIT RUN -BLANK- -BLANK-
TYPE GAUGE QUANTITY TYPE SIZE LENGTH INVERTER#2 80A 24679
TESLA-MODEL 1538000-xx-y[240V] O 4 MAIN
1 PVWire 10 6 N/A N/A 15' INVERTER-UNGROUNDED WITH
INTEGRAL DC ISOLATOR SWITCH
EGC 6 2 N/A N/A 15' 120/240 VAC,1-PHASE
2 MC Cable 10 6 N/A N/A 20' MAX 32 AMP O Co.,
10 Combiner
EGC 6 2 N/A N/A 20' G G G
MAIN
3 THWN-2 10 6 PVC SCH.80 1.50" 25' ♦ ♦ (PPV)PANEL A/C SERVICE
EGC 6 2 PVC SCH.80 1.50" 25' •_ PHOTOVOLTAIC DISCONNECT PANEL
SERVICE RATED SERVICE RATED
4 THWN-2 8 6 PVC SCH.80 1.25" 15, DC STRING#1 ENCLOSURE
IS 5 ENCLOSURE 5 LO
EGC 10 2 PVC SCH.80 1.00" 15' DC AC MAIN-10k AIC MIN.100A 0)
5 THWN-2 4 6 PVC SCH.80 1.50" 10, EGC MIN.EXTERI C:IO
INPUT OUTPUT r
GEC 8 2 PVC SCH.80 1.50" 10' EXTERIOR BUILDING r N
G DISCONNECTING MEANS GROUNDING CO
1 2 3 DC STRING 4 ELECTRODE Z
INVERTER Z
ROOF ATTIC EXTERIOR O U � T_0 I_—
U
IM U +.
N
U. U Cz
— o �
Circuit# PV Module Qty. Inverter Qty. Maximum AC Operating Current i Cz
cncn F-
1 REC420AA Pure 2 11
Tesla Solar Inverter 7.6kW 1 32 A o m
2 REC420AA Pure 2 11 O
.a Cz
3 REC420AA Pure 2 8 Tesla Solar Inverter TRW 1 32 A LO �
Maximum AC Operating Current(Total) 64 A E1 = 1
ONE-LINE DIAGRAM
LABEL LOCATION: LABEL LOCATION: G\STEWARNING:PHOTOVOLTAdC IQ�
CONDUITS:1 AT EVERY SEPARATION BY ENCLOSURES/WALLS/PARTITIONS Service Disconnect MAIN DISCONNECT PANEL: 1 OF EACH AT BUILDING MAIN DISCONNECPOWERSOURCE CHI O�
CEILINGS/FLOORS OR MORE THAN 10'. PANEL
SPLICE/COMBINERS:1 AT ANY COMBINER BOX IF USED NEC 2017 705.10
AW
NEC 2017 690.31(G)(3)/NEC 2017 690.33(E)(2) - • • • • ` Z n
p i 11'
Located next to Meter Pan 0
�V!!YORE
DO NOT DISCONNECT -- - — ------- --- ---
UNDER LOAD LABEL LOCATION:
! •
MAIN DISCONNECT PANEL: 1 OF EACH AT BUILDING MAIN SERVICE SUNATION
This building is equipped with an DISCONNECT PANEL AND UTILITY METER ``
---- -- --- -- — -- --- -- ----- Interconnected Electric Power ENERGY
LABEL LOCATION Production Source NEC 2017 705.10 SUNation Solar Systems
PHOTOVOLTAIC • i • NOT REMOVE 171 Remington Blvd.
Ronkonkoma,New York 11779
MAXIMUM AC OPERATING AC DISCONNECTING MEANS: 1 AT EACH AC DISCONNECT,COMPLETE VOLTAGE
Source Type: (631)-750-9454
AND CURRENT VALUES ON DISCONNECT LABEL. I
NOMINAL •. Solar Photovoltaic NYSERDA
NEC 2017 690.54/NEC 2017 690.13(B) Disconnect is Located: Interior. INSTALLER 4 3 5 5
Basement:_ Garage:_ Exterior._ NUMBER
Front:_ Rear: LH Side:
RHSide: Other Location: JOB NUMBER
Disconnect 8ME SUNation Solar Systems
Service G ww.sun0-9454
w 24679
i 631-7 -94 4
ELECTRIC SHOCK HAZARD -
DO NOT TOUCH TERMINALS
DisconnectPrimary Service TERMINALS ON BOTH THE LINE AND
Service LOAD SIDES MAY BE ENERGIZED LABEL LOCATION:
Located IN THE OPEN POSITION •
PHOTOVOLTAIC MODULES PRODUCEDCVOLTAGE INVERTER/AC DISCONNECT/DC DISCONNECT: 1 AT EACH OF THE
WHENEVERTHEYAREEXPOEDTOSUNUGHT EQUIPPED WITH WID NOTED LOCATIONS
LO
SHUTDOWN NEC 2017 690.56(C)(1)(a) C
---- --- -- --- - CV
O
r CV
PV SYSTEM DC
DISCONNECT LABEL LOCATION: } Ib
SOLAR SYSTEM EQUIPPED Z
•• -• DC DISCONNECT: 1 AT EACH INTEGRATED DC DISCONNECT. COMPLETE VOLTAGE WITH RAPID SHUTDOWN Z 0 r
AND CURRENT VALUES ON DC DISCONNECT LABEL. U = r
OPERATING •LTAGE: C 0)
MAXIMUM SYSTEM VOLTAGE: NEC 2017 690.53/NEC 2017 690.13(B) TURNRAPISWITCHTOTH OWNi L3 t
"OFF'POSMON TO A�4\ Q 4— N'
SHORT SHUTDOWNPVSYSTEM l LLcc U ANDREDUCETHE Z U _ Iis
z
SHOCKHAZARD
LLI
IN ARRAY F 2=
(i) Cn
!� C
O
O
ELECTRIC SHOCK HAZARD PECTRIC SHOCK HAZARD cd
to 0
THE DC CONDUCTORS OF THE DC CONDUCTORS OF
THIS PHOTOVOLTAIC SYSTEM THIS PHOTOVOLTAIC SYSTEM
ARE UNGROUNDED AND ARE UNGROUNDED AND
MAY BE ENERGIZED MAY BE ENERGIZED
E2=1
PV LABELS
\S /�F
;' .?; '• '�'�i�' �G AFC ®'9,p
wY
SUNATION
ENERGY
SUNation Solar Systems
a 171 Remington Blvd.
Ronkonkoma,New York 11779
c (631)-750-9454
� ii e � .- a'C~'.h .�. ✓� .
x=, SERDA IN 4355
INSTALLER
s. r • NUMBER
JOB NUMBER
24679
ARRAY LOCATION(S) ARRAY LOCATION(S) SATELLITE IMAGE
VIA GROUND VIA ROOF
LO
cr) It
0) N
T O
N
r o
J r a� aS r
Q O O
��•'' L 4)
_ U
O N
Z U cu
w W _V
c
t 3 U m
' \ G
��e•, Q
(0
n�
FR
SOUTH VIEW PROPOSED PV EQUIPMENT EXISTING UTILITY METER
VIA ROOF LOCATION AND MDP G1 = 1
— -- --- - -- PV PHOTOS
�
SUNATION,
ENERGY
June 24th, 2025
Solar Permit Closeout
Town of Southold
Permit# BP51644 — 30 Panels
Matthew Sirico o�� ���t
665 Moose Trail Blown 01 a
Cutchogue,,NY 11935
Kind Regards,
Jasmine Fuentes
Residential Project Coordinator
Permitting(asunation.com
631-750-9454 Ext. 306
i
RONKONKOMA, -
r
,r
S
0
I
DUALPOWr R;'J
SOURCIES:`i IUTY GRID u 1
AND PV SCli AR
ELECTRIC SYSTEM d — DUAL POWER SUPPi
CT RIGHT SIDE OF GARAGE 1 • I SOURCES:ura ITY GPJD
X AND PV SOLAR
equiPP ELECTRIC SYSTEM ..
"
eted El
tion S X DISCONNECT RIGHT SIDE OF GARAGE
equipp
c� cted Electric
lion Source
�J
X
-
6w En�►e7
sso-g4ss
�s
AMI