Loading...
HomeMy WebLinkAbout51644-Z ~O�tof SOplyo`p Town of Southold * P.O. Box 1179 roc 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46935 Date: 03/27/2026 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 665 Moose Trail Cutchogue, NY 11935 Sec/Block/Lot: 103.-4-47 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 12/23/2024 Pursuant to which Building Permit No. 51644 and dated: 02/13/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to: Matthew Sirico ,Allison Sirico Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51644 3/23/2026 PLUMBERS CERTIFICATION: Au o ' ed i ture Ao��OfSOUIy�IG TOWN OF SOUTHOLD BUILDING DEPARTMENT ' TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51644 Date: 02/13/2025 Permission is hereby granted to: Matthew J Sirico 665 Moose Trl Cutchogue, NY 11935 To: install roof-mounted solar panels to existing single-family dwelling as applied for. Premises Located at: 665 Moose Trail, Cutchogue, NY 11935 SCTM# 103.-4-47 Pursuant to application dated 12/23/2024 and approved by the Building Inspector. To expire on 02/13/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 ELECTRIC -Residential $125.00 -RESIDENTIAL $100.00 Total $325.00 -- — ------------------ Building Inspector *pF SO(/Tgolo Town Hall Annex Telephone(631) 765-1802 54375 Main Road N P.O.Box 1179 iQ Southold,New York 11971-0959 �li`100um,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Matthew J Siricio Address: 665 Moose Trail city: Cutchogue st: NY zip: 11935 Building Permit#: 51644 Section: 103 Block: 4 Lot: 47 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Electrician: Sunation License No: 33412ME SITE DETAILS Office Use Only Commercial Indoor X Basement Service Solar X Residential X Outdoor X 1st Floor Pool Battery Storage As-built Renovation 2nd Floor Hot Tub EV Charger New X Addition Attic Spa Generator Surveyl IMezzanine Garage Dock17 INVENTORY Service 1 ph In-wall Heater Recpt Ceiling Fixtures Smoke Detectors Pump Service 3 ph Hot Water GFCI Recpt Wall Fixtures CO Detectors Heater Main Panel A/C Condenser Single Recpt RecessdFixtures Combo Smoke/CO Transformer Sub Panel A/C Blower Range Recpt Ceiling Fan Heat Detectors Salt Gen Transfer Switch Mini Split Dryer Recpt UC Lights Fridge AutoCover ARC Blower Heads Switches Pucks Lights Dishwasher Mini Fridge GFI SepticDisconnect Emrgency Strobe 4'LED Microwave Garbage Disp. ARC/GFI ERV Exit Lights Bath Exhaust Hood Dehumidifier Other Equipment: 12.6kW Roof Mounted PV Solar Energy System w/(30)REC420AAPure2 Modules, 80A Disconnect, 80A Combiner Panel w/ (3)Strings to Roof, Lineside Tapped in Main Notes: Solar Date: 3/23/26 Inspector Signature: o�apf SOUTyOI � o # TOWN OF SOUTHOLD BUILDING DEPT. 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ZIR UGH PLBG. ] FOUNDATION 2ND [ ULATION/CAULKING FRAMING / STRAPPING [ AL 540orvoo, [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] -FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] .PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR O�aOF SOUTyO� v coo SG [I aC•�` ---- # TOWN OF SOUTHOLD BUILDING DEPT. 'roorm��'' 631-765-1802 INSPECTION . [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ '] -FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Z 0 l Ct DATE ` 9.18 9-, INSPECTOR Of SOUTyO --- N TOWN OF SOUTHOLD BUILDING DEPT. "�a +N 631-765-1802 FNSPECTION ' [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [. ] FIRE RESISTANT.PENETRATION [ ] ELECTRICAL (ROUGH) [X] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ]' PRE C/O [ ] RENTAL REMARKS:V.4&\l o0c, :6&k io dot rlafn_e i -� nj IM C, C��It, CA, Wj et4c+ of ��- qb rilea 0 ,e tk ����- �Ot' wiev vac. l oce din, opt DATE 7 a a� INSPECTOR o�aOF SOUTyOI _ - - �Ir� TO l * # �FIOUTHOLD BUILD NG DEPT. coo 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] .FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) LECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS. DATE �7 Z INSPECTOR ,�UP1 2 l 2025 tet Graham CO11SU1 ing CO1'p 256-A Oi•iiioco Di•ive, Be•irht.ivateiis;'N_S1sl1718_ Building Consultants&Expeditors (631)665-9619 Fax(631)969-0115 April 18, 2025 Town of Southold Post Installation Certification Permit# BP51644 Sirico Residence - 665 Moose Trail, Cutchogue, NY 11935 Installation Date: 4/15/2025 Inspection Date: 4/17/2025 To Whom It May Concern, The roof mounted photovoltaic system at the above referenced residence has been generally observed to be installed properly in accordance with the approved plans and is certified by Michael K. Dunn, PE, to be in compliance with the minimum requirements,of the Town, the 2020 Residential Code of New York State, 2018 International Residential Code (2018 IRC), Long Island Unified Solar Permit Imitative (LIUSPI), and National Electric Code 2017, and the provisions of ASCE 7-16. If you have any fiirther questions, do not hesitate to call. Sincerely, O CO RA STAT�- MELD INSPECTION REPORT DATE COMMENTS IOUNDATION (IST) ------._..--.__ - ----- ----- - --------- FOUNDATION (2ND) z ROUGH FRAMING & --- - ---- - - � PLUMBING r INSULATION PER N. Y. ------ t� STATE ENERGY CODE iL FINAL - - -- -- ----- ADDITIONAL COMMENTS v J •� w �tbj_� s CA Qo x _......... - --- ------ - ------------ - ---------- '� b ��o�gtlFFOIK�oGy� TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. 0.Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov- Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only L- D'Ll 2 3 2024 PERMIT NO. Building Inspector: C Z 3 Z02� Applications and forms must be filled out in their entirety.'Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: �a I OWNER(S)OF PROPERTY: Name:Matthew Sirico SCTM#1000-103-4-47 Proj r.ect 11 Address.665 Moose Trail, Cutchogue, NY 11935 Phone#:631-834-8172 Email mat.sirico@gmail..com Mailing Address:665 Moose Trail_, Cutchogue, NY 11935 CONTACT PERSON' Name: Evelyn Polvere/Sunation_Solar Systems Mailing Address: 171 Remington Blvd., Ronkonkoma, NY 11779 Phone#. Y631-750-9454 ext 346 Email ermittin sunation corn -DESIGN PROFESSIONAL INFORMATION: Name:Michael,Dunn, Graham and-Associates Inc. Mailing Address:256A Orinoco Drive, Brightwaters, NY 11718 Phone#:631-665-9120 Email:glenn@grahamassociatesny.com CONTRACTOR INFORMATION: Name:Scott Maskin/Sunation Solar Systems Mailing Address:171 Remington Blvd., Ronkonkoma, NY 11779 Phone#: 631-750-9454 Email:pprmitting@§qpption.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes BNo 1 PROPERTY INFORMATION Existing use of property:Residential Intended use of property: Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ®No IF YES,PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for'all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): ott Maskin I]Authorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Scott Maskin being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of ,20.2 Notary Public LYNN VITA Notary Public, State of New York Registration #01V15068399 PROPERTY OWNER AUTHORIZATION Qualified in Suffolk County (Where the applicant is not the owner) My Commission Expires Oct. 28,20 Matthew Sirico residing at 665 Moose Trail CUtchogUe do hereby authorize Scott Maskin to apply on my behalf the Town f Southold Building Department for approval as described herein. 7/� c Q G Owner's Signature If Da e Matthew Sirico Print Owner's Name 2 w'�IA'.'nl4r;yy_ , SUEE UY�EO BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD 4 o Town Hall Annex - 54375 Main Road - PO Box 1179 W- r" .1 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 roQerrO-southoldtownny.gov seandtc7i southoldtownny.-gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: SUNation Solar Systems, Inc Name: Scott Maskin License No.: 33412-ME email: permitting@sunation.com Address:_ 171 Remington Blvd. Ronkonkoma NY 11779 Phone No.: 631-750-9454 JOB SITE INFORMATION (All Information Required) Name: Matthew Sirico Address: 665 Moose..Trail Cutcho ue NY_ 11935 Cross Street: Phone No.: 631-834-8172 Bldg.Permit#: j email: mat.sirico@gmail.com Tax Map District: 1000 S _ction: 103 Block: 4 Lot: 47 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation of solar panels - flat on roof Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: _A #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect-Service Reconnected - Underground - Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection Formals CO BUILDING DEPARTMENT- Electrical tp'spector 5 2025 Gym TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - O,Box 1179 evnent o Southold, New York 1 1 971-0959 ;e�tti 4d 4f4 O� Telephone (631) 765-1802 - FAX (631) 765-9�502:�"''° rogerr@southoldtownny.gov - seand(a-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 6/19/25 Company Name: Sunation Solar Systems, Inc. Electrician's Name: Scott Maskin License No.: 33412-ME Elec. email:closeout@sunation.com Elec. Phone No: 631-750-9454 ❑✓ I request an email copy of Certificate of Compliance Elec. Address.: 171 Remington Blvd., Ronkonkoma, NY 11779 JOB SITE INFORMATION (All Information Required) Name: Matthew Sirico Address-665 Moose Trail, Cutcho ue, NY 11935 Cross Street- Little Neck Rd Phone No.: 631-834-8172 Bldg.Permit#: BP51644 email: matt.sirico@gmail.com Tax Map District: 1000 Section-.103 Block-. 4 LotA BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: YES ❑ NO -]Rough In ❑ Final Do you need a Temp Certificate?: 0 YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame 0 Pole Work done on Service? Y DN Additional Information: PAYMENT DUE WITH APPLICATION INVE qUG f l EUq Tesla DC Series String w/7esla Mid-Circuit Interrupters)"MCI"(typ.) TEGLA-MODEL 1538006n-y 12AOVf O ^ INVERTER-UNGROUNDED WITH 20`J5 sr INTEGRAL DC ISOLATOR smc" _ TESLA 12DR40 VAC,1-0HASE RI(ty O "a r INVERTER MAX32AMP (�A Ted.MCF2(lypjl 1. �.i I 'V' Module Feoz lNp Q'�'r d SUNATI®N Dc srwluG n '-�"f� ld'� EAtE(:GY W MRAi6(HP) DL—ING n `�Sl SIDE COw>GCTpN SUNabon SDlar Systems EGG AXa40etl TO p.) EGC OC AC 171 Remington Blvd. WPUT OUTPUT Ronkonkoma,New Vork 17779 G 80A \ 200A \ (631)-760-9454 1 2 3 DC SIRING MAIN J MAIN J NYSERDA ROOF ATTIC E1-TERIOR INVERTER NSTALLER 4355 CONDUIT AND CONDUCTOR SCHEDULE krvekil I ,rz NUMBER TAG CONDUCTOR CONDUIT RUN JOB NUMBER INVERTER 02 24679 TYPE GAUGE QUANTITY TYPE SIZE LENGTH TESLA-MODEL 153800Duy1240V1 O 4 V MAIN 1 PVWIre 10 6 WA NIA 15, INVERTER-UNGROUNDED WITR INTEGRAL DC ISOLATORS WITCH EGG 6 2 WA NIA 15, Ule24D VAc,1-PHASE 2 MC Cable 10 6 WA NIA 20' MAX 32 AMP (D c2i A EGG 6 2 WA NIA 20' 1//f G G GMAIN3 THWN-2 10 6 EMT 1.50" 25' —— ] (Ppy)PANEtRVICEEGC 6 2 EMT 1.50' 25' I« PHOTOVOI-TAIC DISCONNECT P-- SERVICE MTED SERVICE MTEO SERVICE RATED 4 THWN-2 8 6 PVC SCH.80 1.25" 15' DC STRING 41 ENCLOSURE IS ENLLD$IIRE ENCLOSURE EGG 10 2 PVC SCH.80 1.00" 15' RATED-00A 5 MIGO AD N.1— 6 NIN.100A 7 EGG INPUT OUTPUT MAIN-10k AN: MIN.Yak AIC MW.22k AIC S THWN-2 4 3 CARFLEX 1.50" 10' — IOR EGG 8 1 CARFLEX 1.50" 10, G DISLON ECTING MEANS GROUNDING l'N 6 THAN-2 4 3 CARFLEX 1.50" 10, 1 2 g Dc scTna aR 4 ELECTRODE r N EGC 8 1 CARFLEX 1.50" 10, RCOF Amc EXTERIOR I )- 7 THAI 4 3 PVC SCH.80 1.50" 10, J Z GEC 8 1 PVC SCH.80 1.50" 10, Z r 0 U 7 a a)) o 0 IV U.z U cis o= ❑ Circuit# PV Module Oty. Inverter Oty. Maximum AC Operating Current LU cis rn Cn H 1 REC420AA Pure 2 11 0) m Tesla Solar Inverter 7.6kW 1 32 A 2 REC420AA Pure 2 11 m 3 REC420AA Pure 2 B Tesla Solar Inverter 7.6kW 1 32 A m co Maximum AC Operating Current(Total) 64 A E1 -1 ONE-LINE DIAGRAM Graham Associates 256 Orinoco Drive, Suite A Brightwaters,NY 11718 Planning& Design (631)665-9619 December 19, 2024 ' Town of Southold Building Department 54375 Rt. 25 Southold, NY 11971 Re: Sirico Residence 665 Moose Trail Cutchogue, NY Proposed 12.6 KW PV System To Whom It May Concern, Please be advised that I have analyzed the existing roof structure at the above-mentioned premises and have determined that it is adequate to support the additional load of the solar panels and a 140 mph wind load and 20 psf snow load-without overstress, in accordance with the following: The 2020 New York State Uniform Fire Prevention and Residential Building Code; Town of Southold Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020 National Electric Code including ASCE7-16 If yo qq , rther questions, do not hesitate to call. `P IXyr b298�� -�0 OF 1� Michael K Dunn, RA SnapNrack@ Ultra Rail Roof Mount System IM -.� ;. .. ....... i r�,f15 y, M The Ultimate Value in Rooftop Solar • Industry leading Wire Mounts available for all Management Solutions roof types Aft All SnapNrack Module Sin • - • • InstallatClampsion �i// iAccessories arecompatible with both railprofiles Start Installing Ultra Rail Today r SnapNrack snap-inA sleek, straightforward rail solution for mounting solar modules on all roof types. Ultra Rail now features one rail profile, UR-45, a lightweight eafl profile that's suited for,all, geograph'ic regions, with varying span capabilities. UR-45 Rail maintains all the great features of SnapNrack rail like . . . . an open rail channel for integrated wire management. The Ultra Rail portfolio features multiple roof attachment sealing technologies for all: install preferences. NEW! UltraFoot Roof Attachments • Features SpeedSealT"'+ Technology, a pre-installed butyl pad for easy peel & stick installation _ - • The only single lag roof attachment with butyl sealing available • UltraFoot available in (3) configurations to accomodate rafter & deck mounting based on DeckAnchorT" or wood screw install preferences • All UltraFoot designs feature new Flip Clamp Mount that centers load over fastener & creates an easier snap-in experience with UR-45 Rail The Entire System is a Snap to Install • Ultra Rail Mounts include snap-in brackets for attaching rail 00 • Ultra Rail Mid Clamps & End Clamps are one-size- fits-all universal clamping height • Universal End Clamps & snap-in End Caps provide a clean look to the array edge Unparalleled Wire Management • Open rail channel provides room for running wires resulting in a long-lasting quality install • Module clamps eliminate bolt interference in the rail channel creating more space for wire management • Industry best wire management offering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits & Conduit Clamps • System is fully bonded & listed to UL 2703 Standard DESCRIPTION: DOC NUMBER: SNAPNRACK, TDS, UR-45 RAIL SNR-DC-01420 5nn (apNr(aCk@ DRAWN BY: PART NUMBER(S): H.WULFEKOETTER SUNRUN INSTALLATION SERVICES INC. 232-10095, 232-10096, 232-10097, 232-10098, REV: DATE: 225 BUSH STREET,SUITE 1400.SAN FRANCISCO,CA 94104 USA PHONE(B77)732-2860.CONTACT®SNAPNRACKCOM MEINFORMATION IN MIS ORAWINO IS CONFIDENN AND PROPRIETARY.MY UNITS: IN, LB, DEG [MM, KG, DEG] SHEET: 1:1 3/6/2024 REPROOUCT ON,DSC OSURNSENT FSUNRUF S PRO LLC.DWMOUTME WS.-CONSENTO THIER-N SOIRN LLC. UR-45 RAIL PROPERTIES SKU FINISH RAIL LENGTH WEIGHT (lb) 232-10095 MILL 172 in 5.55 232-10096 BLACK 172 in 5.55 232-10097 MILL 94 in 3.03 232-10098 BLACK 94 in 3.03 .740 .895 SECTION PROPERTIES A 0.319 in Ixx 0.134 in .855 Iyy 0.121 in Sx (TOP) 0.152 in3 Sx (BOT) 0.156 in3 Sy (LEFT) 0.164 in3 Sy (RIGHT) 0.164 in3 MATERIALS: 6005-T5 ALUMINUM DESIGN LOAD (LBS): N/A ULTIMATE LOAD (LBS): N/A TORQUE SPECIFICATION: N/A FT-LBS CERTIFICATION: UL 2703, FILE E359313 WEIGHT (LBS): 5.48 - 5.62 (172 in), 2.96 - 3.10 (94 in) Solar Shutdown Device 1 Technical Specifications The Solar Shutdown Device is a Mid-Circuit Interrupter(MCI)and is part of the PV system rapid shutdown (RSD)function in accordance with Article 690 of the applicable NEC. When paired with Tesla Solar Inverter,solar array shutdown is initiated by any loss of AC power. Electrical Nominal Input DC Current Rating(IMP) 12 A Specifications Maximum Input Short Circuit Current(I5C) 19 A Maximum System Voltage(PVHCS) 600 V DC RSD Module Maximum Number of Devices per String 5 Performance Control Power Line Excitation Passive State Normally Open Maximum Power Consumption 7 W Warranty 25 years Environmental Ambient Temperature -40°C to 50°C(-40°F to 122°F) Specifications Storage Temperature -300C to 700C(-220F to 158°F) Enclosure Rating NEMA 4X/IP65 Compliance Certifications UL 1741 PVRSE, UL 3741, Information PVRSA(Photovoltaic Rapid Shutdown Array) RSD Initiation Method PV System AC Breaker or Switch Compatible Equipment See Compatibility Table below Mechanical Model Number MCI-1 Specifications Electrical Connections MC4 Connector 250 mm Housing Plastic M4 Screw Dimensions 125 mm x 150 mm x 22 mm 650 mm 150 mm M8 Bolt (5inx6inxlin) Weight 350 g (0.77 lb) Nail/ Wood Screw Mounting Options ZEP Home Run Clip V M4 Screw(#10) -- -- ---- ---- M8 Bolt(5/16") Nail/Wood screw H 125 mm >►� 22 mm UL 3741 PV Hazard Control (and PVRSA) Compatibility Tesla Solar Roof and Tesla/Zep ZS Arrays using the following modules are certified to UL 3741 and UL 1741 PVRSA when installed with Tesla Solar Inverter and Solar Shutdown Devices. See Tesla Solar Inverter Rapid Shutdown: Module Selection Based on PV Hazard Control System Listing for guidance on installing Tesla Solar Inverter and Solar Shutdown Devices with other modules. Brand Model Required Solar Shutdown Devices Tesla Solar Roof V3 1 Solar Shutdown Device per 10 modules Tesla Tesla TxxxS (where xxx=405 to 450 W, increments of 5) 1 Solar Shutdown Device per 3 modules 7 Tesla Tesla TxxxH (where xxx=395 to 415 W, increments of 5) 1 Solar Shutdown Device per 3 modules Hanwha Q.PEAK DUO BLK-G5 or Q.PEAK DUO BLK-G6+ 1 Solar Shutdown Device per 3 modules 7 Exception:Tesla solar modules installed in locations where the max Voc for three modules at low design temperatures exceeds 165 V shall be limited to two modules between Solar Shutdown Devices. Tesla Solar Inverter and Solar Shutdown Device Datasheet 4 Tesla Solar Inverter Technical Specifications Mechanical Specifications Dimensions 660 mm x 411 mm x 158 mm (26 in x 16 in x 6 in) 00 00 00 7 M L o0 00 00 00 00 00 •oo 660 00 mm o0 000 00 00 411 mm 0 �158 I I mm Weight 52 Ib5 Mounting Options Wall mount(bracket) 5 Door and bracket can be removed for a mounting weight of 37 lb. Environmental Specifications Operating Temperature -30oC to 450C(-220F to 1130F)6 Operating Humidity(RH) Up to 100%,condensing Storage Temperature -30oC to 700C(-22°F to 158°F) Maximum Elevation 3000 m(9843 ft) Environment Indoor and outdoor rated Enclosure Rating Type 3R Ingress Rating IP55(Wiring compartment) Pollution Rating PD2 for power electronics and terminal wiring compartment, PD3 for all other components Operating Noise @ 1 m <40 db(A) nominal, <50 db(A) maximum 6 For the 7.6 kW Tesla Solar Inverter,performance may be de-rated to 6.2 kW at 240 V or 5.37 kW at 208 V when operating at temperatures greater than 45°C. Compliance Information Grid Certifications UL 1741, UL 1741 SA, UL 1741 SB, IEEE 1547-2018, IEEE 1547.1 Safety Certifications UL 1741 PVRSS, UL 1699B, UL 1998(US), UL 3741 Emissions EN 61000-6-3(Residential), FCC 47CFR75.109(a) Testa Solar Inverter and Solar Shutdown Device Datasheet 3 Tesla Solar Inverter Technical Specifications Electrical Specifications: Model Number 1534000-xx-y 1538000-xx-y Output (AQ Output(AC) 3.8 kW 7.6 kW Nominal Power 3,800 W 7,600 W Maximum Apparent Power 3,328 VA at 208 V 6,656 VA at 208 V 3,840 VA at 240 V 7,680 VA at 240 V Maximum Continuous Current 16 A 32 A Breaker(Overcurrent Protection) 20 A 40 A Nominal Power Factor 1 -0.9(leading/lagging THD(at Nominal Power) <5% Electrical Specifications: MPPT 2 4 Input (DQ Input Connectors per MPPT 1-2 1-2-1-2 Maximum Input Voltage 600 VDC DC Input Voltage Range 60-550 VDC DC MPPT Voltage Range 60-480 VDC1 Maximum Current per MPPT(IMP) 13 Az Maximum Short Circuit Current per 17 Az MPPT(Isc) Maximum current. 2 Where the DC input current exceeds an MPPT rating,jumpers can be used to allow a single MPPT to intake additional DC current up to 26 A IMP/34 A Isc. Performance Peak Efficiency 98%at 208 V 98.4%at 208 V Specifications 98.1%at 240 V 98.6%at 240 V CEC Efficiency 97.5%at 208 V 97.5%at 208 V 97.5%at 240 V 98.0%at 240 V Allowable DC/AC Ratio 1.7 Customer Interface Tesla Mobile App Internet Connectivity Wi-Fi (2.4 GHz,802.11 b/g/n), Ethernet,,Cellular(LTE/4G)4 Factory-Installed Revenue Grade Meter Revenue Accurate(+/-0.5%)s AC Remote Metering Support Wi-Fi (2.4 GHz,802.11 b/g/n), RS-485 Protections Integrated arc fault circuit interrupter(AFCI), Rapid Shutdown Supported Grid Types 60 Hz,240 V Split Phase 60 Hz,208 V Wye 3 Applicable to Tesla Solar Inverter with Site Controller(1538000-45-y)only. 4 Cellular connectivity subject to network operator service coverage and signal strength. Tesla Solar Inverter and Solar Shutdown Device Datasheet 2 Testa Solar Inverter with Solar Shutdown Device Tesla Solar Inverter completes the Tesla home solar system, converting DC power from solar to AC power for home consumption. Tesla's renowned expertise in power electronics has been combined with robust safety features and a simple installation process to produce an outstanding solar inverter that is compatible with both Solar Roof and traditional solar panels. Once installed, homeowners use the Tesla mobile app to manage their solar system and monitor energy consumption, resulting in a truly unique ecosystem experience. KEY FEATURES • Built on Powerwall technology for 0.5%revenue-grade metering for Solar Renewable exceptional efficiency and reliability Energy Credit(SREC) programs included • Wi-Fi, Ethernet,and cellular connectivity 3.8 kW and 7.6 kW models available with easy over-the-air updates • Designed to integrate with Tesla Powerwall and Tesla App T—9.L.,^ r 111 _ p$ o �m E$ T ?'2 � w {.' �s4� F T b.R# r 2 *�H'� ,�yyitK�✓w�t ;�`� � ti ,�'f?4�. s 4w '; March 5,2023 RNIFURHARE C PRODUCT SPECIREATION5 GENERAL DATA * . _ _ 36.4 t0.1 18.5i0.1 Cell type: 132 half-cut REC heterojunction cells with lead-free, 6.os gapless technology,6 strings of 22 cells in se ries Glass: 0.12in solar glasswith anti-reflective surface treatment 492 in accordance with EN 12150 Backsheet: H igh ly resistant po lymer(b la ck) 0.24 t0.01 Frame: Anodized aluminum(black) s A Junction box: 3-part,3 bypass diodes,lead-free C31 s IP68 rated,in accordancewith IEC 62790 M Staubli MC4 PV-KBT4/KST4(12 AWG) 0.43 to.01 Connectors: inaccordancewith IEC 62852.IP68onlywhenconnected Cable: 12 AWG solar cable,49.2+49.2 in 0.8 to.oz in accordance with EN 50618 a9.z cs 6.05 Dimensions: 73.4x 40.9 x 1.2 in(20.88 sq-ft) -- Weight: 47.6 lbs(21.6 kg) t-�1.8 0.9 27.3±0.1 Origin: Made in Singapore T l.z Measurements in inches(mm] t ELECTRICAL DATA Product Code':RECxxxAA PURE 2 CERTIFICATIONS _--- ...._ _ ' ._ _ --__-. _ _ _ ._ 1 i-______�_ Power Output-PMAx(Wp) 400 410 420 430 IEC 61215:2016,IEC 61730:2016,UL 61730 Watt Class Sorting-(W) 0/+10 0/+10 0/+10 0/+10 IEC62804 PID IEC61701 Salt Mist Nominal PowerVoltage-VM,,(V) 41.1 41.6 42.2 42.8 IEC62716 Ammonia Resistance u Nominal Power Current-IMPP(A) 9.74 9.86 9.96 10.05 UL61730 Fire Type 2 Open Circuit Voltage-Voc(V) 48.5 48.8 49.1 49.3 IEC62782 Dynamic Mechanical Load IEC 61215-2:2016 Hailstone(35mm) Short Circuit Current Isc(A) 10.60 10.67 10.74 10.81 IEC62321 Lead-freeacc.to ROHS EU 863/201S Power Density(W/ft2) 19.2 19.6 20.1 20.6 ISO 14001,I50 9001,IEC 45001,IEC 62941 Panel Efficiency(%) 20.6 21.1 21.7 22.2 Power Output-PMAx(Wp) 304 312 320 327 oVE �mOe Lead-Free Nominal Power Voltage-VMPP(V) 38.7 39.2 39.8 40.3 -`- `-" -- -- -- TEMPERATURE RATINGS' i- e_ -_ --- Nominal Power Current IMP,(A) 7.86 7.96 8.05 8.12 Nominal Module Operating Temperature: 44°C(±2°C) Z Open Circuit Voltage-Voc(V) 45.7 45.8 46.0 46.2 Temperature coefficient OfPMAx: -0.24%/°C t Short Circuit Current-Isc(A) 8.50 8.62 8.68 8.73 Temperature coefficient ofVoc: -0.24%/°C a Values at standard test conditions(STC air mass AM1.5,irradiance 10.75W/sgft0000W/m2),temperature 77°F(25'C),based ona production spread Temperature coefficient oflsc: 0.04%/°C with a tolerance of P.,Voc&Isc t3%within one watt class.Nominal module operating temperature(NMOT:air mass AM 1.5,irradiance 800 W/m2, temperature687(20'C),windspeed3.3ft/s(lm/s).*Where xxx indicates the nominal power class(P.)atSTCabove. 'The temperature coefficients stated are linear values � MAXIMUM RATINGS J 'WARRANTY_ J DELIVERY_I_N_FORMATION Operational temperature: -40...+8S°C Standard REC ProTrust Pa nets pe r pal let: 33 0 System voltage: 1000V Installed byan REC No Yes Yes Panels per40ftGP/high cube container: 792(24 pallets) - Certified Solar Professional Test toad(f ront): +7000Pa(1461bs/ftz)' System Size All 425kW25500kW Panels per 53 ft truck: 858(26 pallets) Test load(rear): -4000Pa(83.51bs/ftz)' Product Warranty(yrs) 20 25 25 Series fuse rating: 2SA Power Warranty(yrs) 25 25 25 SLOW LIGHT BEHAVIOUR _ m Reverse current: 25A Labor Warranty(yrs) 0 25 10 Typical low irradiance performance of module atSTC: 'Seeinstallation manual for mounting instructions. Power in Year 1 98% 98% 98% o Design load=Test load/1.5(safety factor) o a o Annual Degradation 0.25% 0.25% 0.25% v °-- ----------=--------- a Power in Year 25 92% 92% 92% -------+-------------------- --------- a See warranty documents for details.Conditions apply d .--------"------------------' o ¢ a Availablefrom: m �Irradiance(W/m') m Founded in 1996,REC Grou p is an internationa I pioneering solar energy company dedicated to empowering consumers REC Solar PTE.LTD. �� with clean,affordable solar power.As Solar's Most Trusted,REC is committed to high quality,innovation,and a low 20Tuas South Ave.14 J R carbon footprint in the solar materials and solar panels it manufactures.Headquartered in Norway with operational Singapore 637312 � headquarters in Singapore,REC also has regional hubs in North America,Europe,and Asia-Pacific. post@recgroup.com www.recgroup.com MEL V4 �. SOLAR'S MOST TRUSTED RED 'Ok o. :J 3: z? � 4 'r .;{ COMPACT PANEL SIZE 4. EXPERIENCE 430 WP REIE ����////� 25 YEAR 20.6 PRoTRUST FTz WARRANTY 22.2%*EFFICIENCY LEAD-FREE ELIGIBLE ROHS COMPLIANT PERFORMANCE -�_ PLAN KEY ®Q UTILITY METER 4 -SERVICEDISCONNECT PROPOSED RESIDENTIAL -d° 1. COVER SHEET IN-SUPPLY SIDE CONNECTION (ExT) Al-1 PARTIAL ROOF PLAN O-AUTOMATIC TRANSFER SWITCH PHOTOVOLTAI C S YSTEM D Al-4 ROOF ACCESS PLAN ®'GAS METER S1-1 STRUCTURE ®-MAIN SERVICE PANEL E1-1 ONE-LINE DIAGRAM M_-SUB WIRrLEPANEL 171 RE INSOLARSYSTEMS INSTERDA ALLER 4355 ®-WIRELESS ROUTER 171 REMINGTON BOULEVARD INSTALLER E2-1 PV LABELS RONKONKOMA,NEW YORK 11779 NUMBER ®-INVERTER ACCESS G1-1 PV PHOTOS ®. ROOF -ENPHASE IQ COMBINER - Sirico Residence -PANEL PHOTOVOLTAIC - 665 Moose Trail, Cutchogue, NY 11935 Q ELECTRIC 9-ENPHASE ENVOY ®-SENSE CONSUMPTIONMONITOR -18"-VENTILATION (EXT) Drawn By: M. Danziger- 12/18/2024 -18"-VENTILATION -AC DISCONNECT - - - \5- (]-TESLA GATEWAY (8)PROPOSED PV MODULES �eFtE,D.q/�, ®-TESLAPOWERWALL M9-ENPHASE IG SYSTEM CONTROLLER �+ ``pEL �� �A ®-ENPHASE IG LOAD CONTROLLER XAA i r, 0-ENPHASE IG 10 BATTERY ®-ENPHASE IQ 3 BATTERY _4' US-GENERATION PANEL ®-BACKED UP LOADS CENTER (G) SUB PPV INV INV I/� ® -VENTPIPE - APP D ED AS NOTED �'� °29, AI /`�) ..n-EXTERIOR LOCATION ACCESS 1 ACES -rr :.PEa HESERI'ED F7ri P.t ^+-1ST FLOOR LOCATION 8� Buil TTI� e -BASEMENT LOCATION (B) SS Mjgp /-y/ Town buildingexaminer has received the enclosed document for minimum acceptable - -GARAGE LOCATION �- ris d BY plan submittl requirements of the town as specified in the building and/or Residential Code of the State of New York. This review does not guarantee compliance with that NOTIFY BUILDING DEPARTMENT AT code. that responsibility is guaranteed under the seal and signature of the New York PROPOSED PV SYSTEM 1B"-VENTILATION 631765-1802 8AM TO 4PM FOR THE State licensed design professional of record. That seal and signature has been 18 VENTILATION interpreted as an attestation that,to the best of the licensee's belief and information ,, ,; .; FOLLOWING INSPECTIONS: the work in this document is: Module Type/Oty: (30)REC420AA Pure 2 FO Accurate 1. FOUNDATION-TWO REOI IIRFD . Conforms with governing codes applicable at the time of submission Module Dimension: 73.4"x 40.9"x 1.211 FOR POURED CONCRETE- 0 Conforms with reasonable standards of practice and with view to the Module Weight/PSF: 47.6 Ibs/2.27969348659004 PSF 2. ROUGH-FRAMING&PL II�,1.;,:%. a safeguarding of life,health,property and public welfare is the responsibility of the licensee. Inverter: (2)Tesla Solar Inverter 7.6kWV77-vvvvvvvv & INSULATION System DC Rating: 12.6 kW 4. FINAL-CONSTRUCTION MUST Structural Statement System AC Rating: 15.36 kW/AC BE COMPLETE FOR C.O. 0 The existing structure is adequate to support the new loads imposed by the All CONSTRUCTION SHALL MEET THE photovoltaic module system including uplift and shear. The existing rafter sizes Aurora Estimated AC Production: 17,822 kWh/yr REQUIREMENTS OF THE CODES OF NEW and dimensions conform to RC-NYS 2020 table R802.4.1(2)-Rafter Spans. (22)PROPOSED PV MODULES YORK STATE NOT RESPONSIBLE FOR tLT PV Notes .� FRONT OF HOUSE-FACING STREET OR DRIVEWAY 1. This PV system has been designed to meet all current and applicable fire NEW YORK STATE &TOWN CODES prevention setback pathways per 2020 NYS Residential Code. Proper ground clearance,roof access points,access pathways and ventilation systems shall be A S REQUIRED-AND-EONDITIONS-O provided where necessary. An in depth description of each applicable code AREA RESERVED FOR AHJ: � � ZBA reference and exception for any codes is depicted on the PV-1 plate of this drawing package. 2. Roof shall have no more than a single layer of roof covering in addition to the SOUTNO TOWN PLANNING BOARD solar equipment. 'rTu 3. Installation of solar equipment shall be flush-mounted,parallel to and no more N T n TOWN TRUSTEES than 6-inches above the surface of the roof. 4. Weight of the installed system shall not exceed more than 5-psf N.Y.S. EC 5. Any plumbing vents are not to be cut or covered for solar equipment installation. Any relocation or modification of the vent requires a plumbing permit and X N R n inspection. FULL HOUSE ROOF PLAN SV on wo SCALE:N.T.S. D This PV system has been designed to meet the minimum design standard for building and other structures of the ASCE 7-16 and the 2020 New York State Residential Code. PV1 JOB# 24679 OCCUPANCY OR COVER PAGE USE IS UNLAWFUL REVISION # N/A WITHOUT CERTIFICAT SUNATION OF OCCUPleaiNCY ENERGY REVISED BY N/A ELECTRICAL INSPECTION REQUIRED • ROOF 2 32'-10y2' r\S-T E O�$� RIDGE V ki G�1AE � C 2 n U iy x o �� O2oS 17 a�2 MCI M I O��Y � '4 re @ 0 15'-2y2" V 17'-5" d OSUNATION ENERGY PHOTOVOLTAIC MODULE MF SUNation Solar Systems 171 Remington Blvd. (TYP.) Ronkonkoma,New York 11779 (631)-750-9454 ROOF AREA INVERTER #2 STRING 3 IN SALLE R 4355 1OOF 1 INVERTER #1 NUMBER STRING 1 RIDGE GUTTER JOB NUMBER TYP 2,-4y2, r 3 &y ri w, :` y . a ( ) 24679 w' o- , n v 05 MCI M 1 M I M 1 N O 1T-2" Ud " r r r �� h p +. £ 6�v a r O [[ ",.dr,."' w c F aa a"n ',,4ry4ry m'. & rc A h r *.4+. '"�" y :' N Q _ '>G'� f�: bfi z#* ` ,• ,rf°ii..�." 4F. f =„tY .Y;"S., C� i m MCI M 1 M I M c I 0 lLU m Z 0 ❑ N o m o c CD C O INVERTER #1 `° STRING 2 GUTTER 42'-10Y2' Attachment Spacing: Portrait Attachment Spacing: Landscape Roof# Roof Description Modules Azimuth Tilt Pitch Interior Edge Corner Interior Edge Corner 1 FOH South Roof 22 1670 300 8/12 4811 3211 1611 6411 4811 6411 /�► 2 FOH South Roof 8 1670 300 8/12 48" 32" 16" 64" 48" 64" 3/16" =1'-0" Al = 1 PARTIAL ROOF PLAN SOLAR ENERGY SYSTEMS SST R�o INY) R324.6 Roof access and pathways. Roof access, pathways and G setback requirements shall be provided in accordance with Sections !t� UGH E�/f R324.61 through R324.6.2.1. Access and minimum spacing shall be QG required to provide emergency access to the roof,to provide pathways nt to specific areas of the roof, provide for smoke ventilation opportunity Ex '< t� areas and to provide emergency egress from the roof. (Ac —4 1 Exceptions: c 7� / O p �O 2981 1. Detached, non-habitable structures, including but not limited to 0 detached garages, parking shade structures, carports, solar NE Y trellises and similar structures, shall not be required to provide roof access. 2. Roof access, pathways and setbacks need to be provided Access where the building official has determined that rooftop ROOF operations will not be employed. 3. These requirements shall not apply to roofs with slopes of two SUNATION units vertical in 12 units horizontal(17-percent slope)or less ENERGY [NY] R324.6.1 Pathways. Not fewer than two pathways, on separate _ SUNation Solar Systems roof planes from lowest roof edge to ridge and not less than 36 inches 18"-VENTILATION (ExT 171 Remington Blvd. 914 mm wide, shall be provided on all buildings. Not fewer than one Ronkonkoma,New York 11779 ( ) p 9 -18"-VENTILATION (631)-750-9454 pathway shall be provided on the street or driveway side of the roof. For each roof plane with a photovoltaic array, a pathway not less than 36 inches (914 mm)wide shall be provided from the lowest roof edge (8)PROPOSED PV MODULES _ N/V VV NYSERDA 4355 INSTALLER to the ridge on the same roof plane as the photovoltaic array, on an NUMBER adjacent roof plane, or straddling the same and adjacent roof planes. Pathways shall be over areas capable of supporting fire fighters JOB NUMBER accessing the roof. Pathways shall be located in areas with minimalVV obstructions such as vent pipes, conduit, or mechanical equipment. /� Pathways on opposing roof slopes shall not be located along the same 24679 9 plane as the truss, rafter, or other such framing system that supports the pathway. Exception: (G) SU8 PPV INV INV 1. Access pathways shall not be required on roof slopes containing Ln photovoltaic modules, panels, or an array where the opposing ACCESS co N or adjacent roof slope is an access roof. ROOF N O z Co Access Roof-A roof surface that: (B) S rv�sP F N � m r 1. Can be accessed from the ground by the fire service. Q) 0 m 2. Is capable of providing fire service access to the ridge or peak p r N of an opposing or adjacent roof surface that contains 18"-VENTILATION Z o v co photovoltaic modules,panels,or an array. — 'm 18"-VENTILATION W n` '- 3. Is relatively free of vents,skylights,conduits, mechanical I-- rW equipment and other such obstructions. v) m a vvvvvvvvvvv 2 0 4. Does not contain photovoltaic modules, panels or an array,or is 0 ro a single ridge roof where the maximum edge to edge width of m o the photovoltaic panel system does not exceed 33 percent of the ridge length. [NY] R324.6.2 - Setback at ridge. Photovoltaic arrays shall not be vvvvvvvvvvv located less than 18 inches(457 mm)from a horizontal ridge. [NY] R324.6.2.2 - Emergency escape and rescue opening. Panels and modules installed on dwellings shall not be placed on the portion of the roof that is below and emergency escape and rescue opening. A pathway not less than 36 inches(914 mm)wide shall be provided to w . the emergency escape and rescue opening. (22)PROPOSED PV MODULES FRONT OF HOUSE-FACING STREET OR DRIVEWAY N.T.S. A1 =4 ROOF ACCESS PLAN GASTER�,� Typical Attachment Method �� HAFT°" 0g. CD m n SNAP'N'RACK ULTRA RAIL 1 0 RIDGE RIDGE A/ y0� PHOTOVOLTAIC 171-811 PHOTOVOLTAIC 17'-11" SNAP'N'RACK SPEEDSEAL MODULE MODULE L-FOOT RAIL 3/4"MODULE SPACING 3/4"MODULE SPACING INSTALLERS TO APPLY SEALANT ON BETWEEN ROWS AND BETWEEN ROWS AND BOTTOM SEALANT RING SUN/�TION COLUMNS(TYP.) COLUMNS(TYP.) USE-NPC Solar Seal#900 SHING ELAYER COMPOSITE ENERGY SUNation Solar Systems RAFTER RAIL (1)5/16"X5"m 171 Remington Blvd. 2"X 4"/16"O.C. SEALING LAG SCREW / Ronkonkoma,New York 11779 FASTENED TO RAFTER / / (631)-750-9454 RAFTER / PERLIN INSTALLER 4355 2"X 10"/16"O.C. / � / INSTALLER / NUMBER PLYWOOD DECKING JOB NUMBER (TYP.) WOOD FRAMING 24679 EXTERIOR SOFFIT SOFFIT (TYP-) WALL EXTERIOR WALL ATTACHMENT TYPE APPLIED TO-ROOF"TYP" 13'-7.5" 13'-10" ROOF SECTION (TYP.) - ROOF"1" ROOF SECTION (TYP.) - ROOF"2" SCALE: N.T.S. SCALE: N.T.S. LO m It N T Q r N Oo Z SOLAR MODULE FRAME Q T NOTE:3/4"SPACING 2 I AND COLUMNS.BETWEEN ULE ROWS Q .0 Roof# Rafter Size/Spacing Max Span Material Layers Sheathing N r� °° 00O°°�� END CLAMP Q 0 1 2"x 4" /16" O.C. 13'-7.5" Composite Shingles 1 Oriented Strand Board . �O°°O OOP .Q° O. j a s„ (TYP) ILL U � 0 0000 000° o OOO°O°• Q°°°"�j�C� HEIGHT ADJUSTABLE 0 — 2 2"x 10"/16" O.C. "IT-10" Composite Shingles 1 Plywood . oO ,rOO OO• i _ L-FOOT(TYP.) � •L •M C 0 � SNAP'N'RACK U) m ® e o a o f ULTRA RAIL O O (TYP.) O co • •o°o° o°o° °o°o°°o°a°' aoo 0 000 o Oho°o ooQ�o 5.5" LO HEIGHT OFF C Ln SURFACE ROOF Q CO �'.pd O�O�O r0�40 O�QOO (0 OLATRIM'ST-550'PEST AND Typical Module DEBRIS ARRIER-CUTAWAY Side Profile FOR CLARITY. CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA - TABLE R301.2(1) WIND DESIGN SUBJECT TO DAMAGE ICE BARRIER SEISMIC DESIGN WINTER DESIGN MEAN ANNUAL GROUND SNOW UNDERLAYMENT FLOOD HAZARD AIR FREEZING INDEX - TEMPERATURE SPEED(MPH.) TOPOGRAPHIC WIND BORNE DEBRIS CATEGORY TEMPERATURE SPECIAL WIND ZONE WEATHERING FROST LINE DEPTH TERMITE LOAD EFFECTS ZONE REQUIRED S 1 20 PSF 140 B YES 2 B SEVERE 3'-0" MODERATE TO 15 DEG N/A SEE PLANS 599 51 HEAVY EXAMINER STRUCTURE �GXS E1�F0 co o . z rn e z 0 O INVERTER#1 UTILI w/Tesla Mid-Circuit Interrupter(s)"MCI" t TESLA-MODEL 1538000-xx-y[240V) SERVICE Tesla DC Series String tefS P yp.� INVERTER-UNGROUNDED WITH O ` INTEGRAL DC ISOLATOR SWITCH c�` Y O� TESLA 120/240 VAC,1-PHASE Heisting + O eoc INVERTER MAX 32 AMP PSEG Utility Meter w A Account N-9624080051 I`V,' + 0501745 Tesla MCI-2(typ.) +ve/ Meter# 6201240vModule J-Box(typ.i SUNATI®N ENERGY . . . . . C�J DC STRING#1 PV Module(typ.) 11 0 DC STRING#2 SUPPLY SIDE CONNECTION SUNation Solar Systems EGC Attached To Rail(typ.) DC AC 171 Remington Blvd. EGC INPUT OUTPUT Ronkonkoma,New York 11779 (631)-750-9454 G 80A 1 200A 1 2 3 DCSTRING MAIN J MAIN INNYSERDA ALLE 4355 INVERTER INSTALLER ROOF ATTIC EXTERIOR NUMBER 2P40A 2P40A CONDUIT AND CONDUCTOR SCHEDULE Inverter#1 Inverter#2 JOB NUMBER TAG CONDUCTOR CONDUIT RUN -BLANK- -BLANK- TYPE GAUGE QUANTITY TYPE SIZE LENGTH INVERTER#2 80A 24679 TESLA-MODEL 1538000-xx-y[240V] O 4 MAIN 1 PVWire 10 6 N/A N/A 15' INVERTER-UNGROUNDED WITH INTEGRAL DC ISOLATOR SWITCH EGC 6 2 N/A N/A 15' 120/240 VAC,1-PHASE 2 MC Cable 10 6 N/A N/A 20' MAX 32 AMP O Co., 10 Combiner EGC 6 2 N/A N/A 20' G G G MAIN 3 THWN-2 10 6 PVC SCH.80 1.50" 25' ♦ ♦ (PPV)PANEL A/C SERVICE EGC 6 2 PVC SCH.80 1.50" 25' •_ PHOTOVOLTAIC DISCONNECT PANEL SERVICE RATED SERVICE RATED 4 THWN-2 8 6 PVC SCH.80 1.25" 15, DC STRING#1 ENCLOSURE IS 5 ENCLOSURE 5 LO EGC 10 2 PVC SCH.80 1.00" 15' DC AC MAIN-10k AIC MIN.100A 0) 5 THWN-2 4 6 PVC SCH.80 1.50" 10, EGC MIN.EXTERI C:IO INPUT OUTPUT r GEC 8 2 PVC SCH.80 1.50" 10' EXTERIOR BUILDING r N G DISCONNECTING MEANS GROUNDING CO 1 2 3 DC STRING 4 ELECTRODE Z INVERTER Z ROOF ATTIC EXTERIOR O U � T_0 I_— U IM U +. N U. U Cz — o � Circuit# PV Module Qty. Inverter Qty. Maximum AC Operating Current i Cz cncn F- 1 REC420AA Pure 2 11 Tesla Solar Inverter 7.6kW 1 32 A o m 2 REC420AA Pure 2 11 O .a Cz 3 REC420AA Pure 2 8 Tesla Solar Inverter TRW 1 32 A LO � Maximum AC Operating Current(Total) 64 A E1 = 1 ONE-LINE DIAGRAM LABEL LOCATION: LABEL LOCATION: G\STEWARNING:PHOTOVOLTAdC IQ� CONDUITS:1 AT EVERY SEPARATION BY ENCLOSURES/WALLS/PARTITIONS Service Disconnect MAIN DISCONNECT PANEL: 1 OF EACH AT BUILDING MAIN DISCONNECPOWERSOURCE CHI O� CEILINGS/FLOORS OR MORE THAN 10'. PANEL SPLICE/COMBINERS:1 AT ANY COMBINER BOX IF USED NEC 2017 705.10 AW NEC 2017 690.31(G)(3)/NEC 2017 690.33(E)(2) - • • • • ` Z n p i 11' Located next to Meter Pan 0 �V!!YORE DO NOT DISCONNECT -- - — ------- --- --- UNDER LOAD LABEL LOCATION: ! • MAIN DISCONNECT PANEL: 1 OF EACH AT BUILDING MAIN SERVICE SUNATION This building is equipped with an DISCONNECT PANEL AND UTILITY METER `` ---- -- --- -- — -- --- -- ----- Interconnected Electric Power ENERGY LABEL LOCATION Production Source NEC 2017 705.10 SUNation Solar Systems PHOTOVOLTAIC • i • NOT REMOVE 171 Remington Blvd. Ronkonkoma,New York 11779 MAXIMUM AC OPERATING AC DISCONNECTING MEANS: 1 AT EACH AC DISCONNECT,COMPLETE VOLTAGE Source Type: (631)-750-9454 AND CURRENT VALUES ON DISCONNECT LABEL. I NOMINAL •. Solar Photovoltaic NYSERDA NEC 2017 690.54/NEC 2017 690.13(B) Disconnect is Located: Interior. INSTALLER 4 3 5 5 Basement:_ Garage:_ Exterior._ NUMBER Front:_ Rear: LH Side: RHSide: Other Location: JOB NUMBER Disconnect 8ME SUNation Solar Systems Service G ww.sun0-9454 w 24679 i 631-7 -94 4 ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS DisconnectPrimary Service TERMINALS ON BOTH THE LINE AND Service LOAD SIDES MAY BE ENERGIZED LABEL LOCATION: Located IN THE OPEN POSITION • PHOTOVOLTAIC MODULES PRODUCEDCVOLTAGE INVERTER/AC DISCONNECT/DC DISCONNECT: 1 AT EACH OF THE WHENEVERTHEYAREEXPOEDTOSUNUGHT EQUIPPED WITH WID NOTED LOCATIONS LO SHUTDOWN NEC 2017 690.56(C)(1)(a) C ---- --- -- --- - CV O r CV PV SYSTEM DC DISCONNECT LABEL LOCATION: } Ib SOLAR SYSTEM EQUIPPED Z •• -• DC DISCONNECT: 1 AT EACH INTEGRATED DC DISCONNECT. COMPLETE VOLTAGE WITH RAPID SHUTDOWN Z 0 r AND CURRENT VALUES ON DC DISCONNECT LABEL. U = r OPERATING •LTAGE: C 0) MAXIMUM SYSTEM VOLTAGE: NEC 2017 690.53/NEC 2017 690.13(B) TURNRAPISWITCHTOTH OWNi L3 t "OFF'POSMON TO A�4\ Q 4— N' SHORT SHUTDOWNPVSYSTEM l LLcc U ANDREDUCETHE Z U _ Iis z SHOCKHAZARD LLI IN ARRAY F 2= (i) Cn !� C O O ELECTRIC SHOCK HAZARD PECTRIC SHOCK HAZARD cd to 0 THE DC CONDUCTORS OF THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND ARE UNGROUNDED AND MAY BE ENERGIZED MAY BE ENERGIZED E2=1 PV LABELS \S /�F ;' .?; '• '�'�i�' �G AFC ®'9,p wY SUNATION ENERGY SUNation Solar Systems a 171 Remington Blvd. Ronkonkoma,New York 11779 c (631)-750-9454 � ii e � .- a'C~'.h .�. ✓� . x=, SERDA IN 4355 INSTALLER s. r • NUMBER JOB NUMBER 24679 ARRAY LOCATION(S) ARRAY LOCATION(S) SATELLITE IMAGE VIA GROUND VIA ROOF LO cr) It 0) N T O N r o J r a� aS r Q O O ��•'' L 4) _ U O N Z U cu w W _V c t 3 U m ' \ G ��e•, Q (0 n� FR SOUTH VIEW PROPOSED PV EQUIPMENT EXISTING UTILITY METER VIA ROOF LOCATION AND MDP G1 = 1 — -- --- - -- PV PHOTOS � SUNATION, ENERGY June 24th, 2025 Solar Permit Closeout Town of Southold Permit# BP51644 — 30 Panels Matthew Sirico o�� ���t 665 Moose Trail Blown 01 a Cutchogue,,NY 11935 Kind Regards, Jasmine Fuentes Residential Project Coordinator Permitting(asunation.com 631-750-9454 Ext. 306 i RONKONKOMA, - r ,r S 0 I DUALPOWr R;'J SOURCIES:`i IUTY GRID u 1 AND PV SCli AR ELECTRIC SYSTEM d — DUAL POWER SUPPi CT RIGHT SIDE OF GARAGE 1 • I SOURCES:ura ITY GPJD X AND PV SOLAR equiPP ELECTRIC SYSTEM .. " eted El tion S X DISCONNECT RIGHT SIDE OF GARAGE equipp c� cted Electric lion Source �J X - 6w En�►e7 sso-g4ss �s AMI