Loading...
HomeMy WebLinkAbout53040-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 53040 Date: 06/02/2026 Permission is hereby granted to: North Fork Greek Com Assc PO BOX 1162 Mattituck, NY 11952 To: Install a commercial fire suppression system to existing hood as applied for. Premises Located at: 1950 Breakwater Rd, Mattituck, NY 11952 SCTM# 106.-9-6.1 Pursuant to application dated 06/02/2026 and approved by the Building Inspector. To expire on 06/01/2028. Contractors: q Inspections:Re uire Ins ions:a ............ .......... ................ ..... Fees: _._.__._.....� _._. . ................................. �_ Exhaust Hood and/or Fire Suppression System $300.00 CO Commercial $100.00 Total $400.00 Building Inspector TOWN OF SOUTHOLD —FIRE MARSHAL Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 " Telephone (631) 765-1802 Fax (631) 765-9502 pas://� . )utholdtQ gy FIRE PROTECTION SYSTEM PERMIT Date Received APPLICATION For Office Use Only C' u PERMIT NO. Building Inspector: ctor�., Applications,and forms must be filled out in their,entirety.Incomplete pllcatt on ,yn i not It accepted!."FOR"D&N I''T '' ',M1,F,D'prior, )�J i`,G - 2 2026 to,thea iproyat of plans and'issuance,ofa permit; Has a building permit been obtained for this project? ❑Yes ❑No B ua Diurr a ,,,p'7,ritnent If yes,building permit# Date: o -,2 8- PROJECT INORMATION: Project Address: 9SCTM# 1000- t p 6 _ 1- City: µ, zip: i IQ 5,2 CONTACT PERSON INFORMATION:, Name: Q� -� e peo Mailing Address: © J e Phone#: 63 i- i G N i l Email:p.,.,i .M 0 �•�>'Re k Qc C G M A 1 cow Preferred contact method(select one): C]-Phone ❑Email CONTRACTOR INFORMATION: Name: fN rs �, as Contractor License#: t 1 Mailing Address: .. L � 6 y�rlQ,Rc 1 17 04 Phone#: 63 ,- 316 Email: pI,L.. A,,D,e50,sf,/lelN' C' Gm'a,i.cor, SCOPE OF WORK: Occupancy Description: ❑Assembly T(Business ❑Education ❑Factory/Industrial ❑Institutional ❑Mercantile ❑Residential ❑ Storage Description of Work: P-,C -°-n45-A LL- A `-d,,, t^.X; .1C-5 ❑ New System 56xisting System Modification Sprinkler/Standpipe/Water Supply Fire Alarm/CO Detection Systems Other Fire Protection Systems (Check all that apply) (Check all that apply) (Check all that apply) ❑NFPA 13,13D or 13R System ❑Manual ❑Automatic ❑ Smoke Control ❑Standpipe ❑ Fire Pump ❑Protected Premises (local) R Viet or Dry Chemical/Clean ❑Supervising station Agent Number of sprinkler headsu ❑Central Station ❑ Kitchen hood/exhaust ❑ Other Floor Area(sq. ft.): - - 1 cbecic Box:After Reading: I,the undersigned,understand that the issuance of a permit for the type which4s herein applied for is based,on the agreement to conform to all regulations and requirements-I further understand'that non-eampliance of said requirements;by myseitor wry officer or employee of the:firm-or individual listed as the applicant on,this form,shall:because for revocation of saidpermit Upon revocation ofsaid.permit the applicant or any employee of the,applicant sball be prohibited to conduct such,work.far which this.perruitwasiuroad,The reisauance of a-permit shall be based upon review of the dreuertMates leading to the revocation.Any false statemeut(s)-made herein are punishable as a Klass A misdemeanor pursuant to Section,210.45 of the Penal Law Application Submitted By(print name): ,, r_ T AR a QAuthorized Agent ❑Owner Company if applicable):_ ����� � ...... p y( t i I vim! T_'Ae- ant Signature: Date: -28 .21i FIRE PROTECTION SYSTEM PERMIT APPLICATION SUBMITAL INSTRUCTIONS Submit application only after reviewing the requirements for the specific permit for which you are applying(click the applicable link below). • FIRE,,,,,, I AIM/CARBON MONOXIDE DETECTION TION s"'S" FNa SUB6MITTA:L..GUIDELINES • DIRE SPI INI LER SYS"I"EM SUBMin'AID GUI.IDELINES • FIXED FIRE SUPPRESSION.HOOD i FXtIAI.`ST SYSTEMS SU MITTM.,LAIII)ELINES FEES A$300 permit fee is required for a non-residential permit.A$100 Certificate of Occupancy fee is required if the project is not part of an existing open building permit. All checks should be made payable to the Town of Southold. Permits,once issued,shall at all times be kept on the premises designated thereon with a copy of approved drawings and all related documentation required to obtain said permit.Installations subject to final testing,inspection and approval.Arrangements for testing/inspection shall be made by contacting the Town of Southold Building Department(631)765-1802. FOR OFFICE USE ONLY Amount Paid: Check No.: FM: Permit No.: Date: Exp. Date: 2 Component Description w F A $ 'POP OF e, CENTER OF CYLINDER VALVE '„ DiSCiiARt3E PORT r NOMINAL CYLINDER DIAMETER Figme 2-1. Dimensions of Cylinder and Valve Assembly, P/N B-12XXXX Refer to Figure 5-26 for Cylinder Valve details. Table 2-1.Cylinder and Valve Assembly SPeci$cations cylb"er and Valve 14axinunn D inunaSiMM Assembly Part Ruaaber 11l Ad Flew Muniber A B C (old P/N) 60-120001-001 RG-1.250 4 15-1/4 in. 13-3/4 in. 8 In. (B120001) (387 mm) (349 mm) (203 mm) 60-120002-001 RG-2.5G 8 21 in. 19-5/8 in. 9 in. (B120002) (534 mm) (498 mm) (230 mm) 60-120003-001 RG-4GS 12 19 in. 17-1/2 in. 12-1/4 in: (B120003) (483 mm) (444 mm) (311 MM) 12 24-3/8 in. 23 in. 10 in. (B120006) (619 mm) (584 mm) (254 mm) 60-12(10©5-0(11 RG-6G 18 35-1/8 in. 33-3/4 in. 10 in. (B120005) (892 ten) (857 mm) (254 mm) Note: It is permisible to use old and/or new cylinders included in this manual on a Range Guard system. April 2009 P/N 60-9127100-000 2-3 Component Description 2-1.1.1 CYLINDER BRACKETS A —♦I CY1N'MW STRAP CYLINDER STRAP NOW, � r WE, �umauuuu .:tz� ur sl�oualuu��I q�PIa�R�aICmNII�bOco� rr7��ot�x��wm�mr i � I f i 1 B 1 II � a �--C—� FRONT VIEW SIDE VIEW Figure 2-2. Mounting Brackets Table 2-2. Mounting Bracket Dimensions Dimensions Part No. Model C A B 9197430 RG-1.25G 3 in. 9-3/8 in. 1-3/8 in. (76 rum) (238 mm) (35 mm) 9197263 RG-2.5G 4-1/2 in. 12 in. 2-1/2 in. (114 mm) (305 mm) (64 mm) 4-I/2 in. 20-1/2 in. 2-1/2 in. RG-4GM (114 mm) (521 mm) (64 nun) 9197415 RG-4GS 4-1/2 in. 11-1/2 in. 2 in. (114 mm) (290 mm) (51 mm) April 2009 2-4 p/N 60-91271004M Contponannt DcscriPtbm Table 2-5_Range Gard Nozzles Past Nundw viaw Munabesr t3IVOwes NOzde Tnw (OSdPant Number) 87-120011-001 J (B120011) 87-12 0012-001 (B120012) GRw Nozzle 87-120013.001 1 3 (B120013) ------------ R Nozzle 87-120014-Ml 1 4 ry l (B120014) ISM Nozzle 87-120015-001 3 0 (B120015) LPF Nozzle 87-120022-001 2 1 &4 (B12o022) a 87-120024-001 1 Disc&Core (B120024) Note: It is permissible to use old and/or new nozzles included in this manual in a Range Guard system. P/M 60-91271004M 2-8 April 2009 Component Description ?�S-g Mechanic Gas Valve. P/N B12OO7S Mechanical Gas Valve is required on syslems used to protect gas-fueled appliance(s).Upon system actuation, the control stem closes, stopping the gas fIGW to the apl:liance(s). Note: only Mechanical Gas Valves that are specifically UL listed and identified by part number in this manual may be used with the Range Guard system. i CONTROL STEM E w INLET _ OUTLET 1 k� a yy d 5 � X Figure 2-42. Mechanical Gas Valve.P/N B12OO7X Table 2-17.Mechanical Gas Valve Sizes Size Part Number 3/4 in.(19 MM) op B120071 B120072 j, 1-1/4 in. (32 mm) B120073 1-1/2 in.(38 mm) B 120074 2 in.(51 mm) B120075 2-1/2 in.(64 mm) B120076 3 in.(76 mm) B120077 April 2009 2-38 P/N 60-9127100-000 Component Description 2-2 CONTROLS 2-2.1 UNIVERSAL.CONTROL*tgAD (UCH)Control System,P/N B120099 The UCH Control System, P/N B 120099, is used for ae the Range Guard ,tuatin,g G d Cylinder mid Valve Assembly. The UCH Control System call be attached to the System Valve Actuator, PIN B 120042 for direct cylinder moundvg,or to a wall for remote mounting. Knockouts are provided to accommodate either type of mounting,The controller can be operated with: • Automatic mechanical detection (fusible-links and thermo-bulb links), • Automatic electrical operation, and • Remote and local manual operation. 9-7116 in. (240 mm) .......... -TPA 8.%V16 in. 3-3/4 in. (95 mm) (208 mm) Figure 2-15. UCH Control System, P/N B 120099 ........... Aprfl 2009 PIN 60-91271004M 2-13 Component Description 2-2.4 Remote Manual Releases 2-2.4.1 REMOTE MANUAL RELEASE, P/N B875572 (UCH ONLY) The Remote Manual'Release.shown in Figure 2-35,is provided as a means of manually actuating the system from a remote location. The Remote Manual.Release is attached to the UCH Control System with 1/1 5-inch control cable.To actuate the system at the Remote Manual Release, pull out the safety pin and pull hard on the handle. Each Remote Manual Release is supplied with a separate nameplate. This nameplate must be attached to the mounting surface 1-inch above or below the Remote Manual Release. 3-5/8 in. (92.2 mm) 1412 in. (38 mm) Figure 2-35. Remote Manual Release, P/N B875572 2-31 April 2009 P/N 60-91271004= Component Description 2-2.3.2 UNMRSAL-L HOUSING SIT,P/N 120064 The Universal-Link Housing Kit, shown in Figure 2-29, consists of the following. Table 2-12. Universal Link Housing Kit,P/N 120064 Item Quantity 11-1/2 in. (292 mm)Detlector TI(xia ing 1 Crimp Sleeves �.. .��.�. 2 -S"Hooks 2 The items above are used to attach the Fusible-Link or Thermo-Bulb Links to the 1/16-inch cable leading to the UCH Control System or A+ Control Box.The Universal-Link Housing can be configured as an End-of-Line or In-Line bracket. 1116 in.CABLE TO CONTROL SYSTEM (NOT SUPPLIED) "S"HOOKS CRIMP SLEEVE �vw LOCKNUT THERMO-BULB LINK (NOT SUPPLIED) OR FUSIBLE-LINK dNfro � (NOT SUPPLIED) " THERMO-BULB LINK OR FUSIBLE-LINK (NOT SUPPLIED) CRIMP SLEEVE 112 in.EMT EXAMPLE OF IN4JNE EXAMPLE OF END-0OF-LINE CONNECTOR UNIVERSAL HOUSING KIT UNIVERSAL HOUSING KIT S.HOOK (NOT SUPPLIED) Figure 2-29. Example of End-of-line and In-line Universal Link Housing Kit, P/N 120064 2-25 April 2009 p/N 60-9127100-000 Component Description 2-2.1.6 MICROSWITCH HIT,P/N B120039, B120039-501 (FOR UCH) The Microswitch Kit is a single pole, double-throw switch (see Figure 2-21 and Table 2-7). Included in the kit is the microswitch, pigtail assembly and four mounting screws (two short and two long). Note: Microswitch Kit P/N B 120039-501 includes pigtail assembly with white stripes. The wire leads are 2 -inches(510 min)in length. Four Microswitch Kits can be moi111ted In the UCH Control System, There are two mounting locations to accommodate the four Microswitch kits (two stacked at each mounting location), with EMT ports for each mounting location. This allows for the use of two electrical junction boxes for separation of signal lines and AC lines. These are used when it is necessary to open or close electrical circuits. The following are examples, but not limited to: • Electric appliance shutdown • Make up air shutdown • Electric gas valve shutdown • Shuntbreaker/relay Note: Not for alarm initiation. Electrical appliances usually have a higher amp rating than the switches.In this case,such appliances shall not be wired directly to the microswitch. A magnetic contactor or relay must be used. To wire the microswitch for UCH, refer to Figure 4-30. ELECTRICAL CONNECTOR f rrrwrwr MICRO5WITCH Figure 2-21. Microswitch Kit, P/N B120039 Table 2-7. Microswitch Electrical Ratings 125/250 Vac 20.5 Amps 250 Vac 1-1/2 HP 125 Vac 1/2 HP April 2009 2-18 PIN 60-9127100-OW Component Description 2-2.3.7 CORNER PULLEY, P/N MR-844648-900 Comer Pulley is used to ebange the direction of the control cable ru11s. The cable's protective conduit(1/ -inch EMT)is attached to the Corner Pulleys with the coupling nuts provided.The Corner Pulley is equipped with a ball-bearing pulley for minimum resistance to the cable travel,. 3 in. (76.2 mm) 3 in. (76.2 mm) Figure 2-33. Corner Pulley,P/N WK-844648-900 PM 60-9127100-000 2-29 April 2009 System Design 3-6 VENTILATION "A Plenums Table 3-29. Plenum Protection Items ADP Nozzle No Filter 1 10 ft.x 4 ft.(3 m x 1.2 m)Max. i -located at one end of the plenum "V"Filter 10 ft.x 4 ft.{3 m x 1.2 m) 1 -located at one end of the plenum 20 ft.x 4&(6 m x 1.2 m) 2-located at end of plenum pointing inwards %p lt ' ,rIiJ ft.x 4 ft (3 1.,2 1, I -located at one end of the plenum 20 ft.x 4&(6 m x 1.2 m) 2-located at end of plenum pointing inwards i When no fitters are present, the nozzle protecting the plenum is used to discharge the wet chemical on the under- side of the hood.in this case, tite hood may not exceed a length of 10 fL(3 m)or a width of 4 ft (1.2 m). Plenunis larger than 10 ft. (3.0 m)x 4 ft. (1..2 tn)may be protected by adding additional ADP nozzles for each additional 10 ft. (3.0 in)of plenum length and each additional 4ft. (l.2 tn)of plenum width. Nozzles may be installed: pointing in the same direction, and/or at the ends of the plenum pointing toward each.other(see Figure 3-2 ).Each nozzle will provide coverage for a nl nittxn of 10 it, (3 m) of plenum length and 4 ft. (1.2 m) of plenum width. ADP nozzles must:be centrally located in the plentun with their discharge directed along the length of the plentttn and located in relation to the filters as shown in Figure -28.Refer to Figure 3-28 for filter height. 3 33 April 2009 P/N 60-9127100-000 V"ign ".1.1.2 Ducts 50 to 100 inches in Perimeter o ADP nozzles, P/N 87.12 11-00 1, pointing In the same direction are required for protectio" of ducts with perimeters greater than 50 inches and less than or equal to 100 inches. Ducts can be of unlimited length(refer to Figure 3-30)• For other option of ducts up to 75 perimeter inches (See Figure 3-32). Note: All Range Guard systems are listed by UL and ULC for use with the exhaust fan either on or off when the system is discharged. DUCT HOOD X. X 1/4d 1/2d MAX.DIAMETER 31.53 in.(809 mm) X. i/4X %X NOZZLES TO BE ALONG ONE 25 in.(035 mm) A, CENTERLINE AT THE 114 POINTS. MAX.SIDE NOZZLES TOO BE 0-0 in.(0.152 mm) UP FROM ENTRANCE OF VERTICAL DUCT MAX.DIAGONAL 11.78 K(300 mm) MAX.DIAGONAL TYP.(2)ADP NOZZLES 11.78 in.(300 mm) ROUND SQUARE RECTANGULAR ADP NOZZLE q 01o0In. (O�Ia 152 mm) DUCT ENTRANCE IL OF VERTICAL DUCT — - L OF HORIZONTAL DUCT 2-4 In,(51 mm-102 mm) ADP NOZZLE �,� AIM POINT NOZZLE TIP TO DUCT HIP t VERTICALIHORIZONTAL DUCT Figure 3-30. Duct Protection Using Two ADP Nozzles, P/N 87-120011-001 April2009 3- p i271 System Design 3-4.4 14 in. x 14 in. (356 mm x 356 mm) Deep Fat Fryer Table 3-5. F Nozzle Coverage Area items Pammeters Maximum Hazard Area 14 in.x 14 in. (356 mm x 356 mm) Maximum Appliance Area(with drip board) 14 in.x 24-1/2 in.(356 mm x 622 mm) Nozzle Aim Midpoint of hazard area Nozzle Location(from top of appliance at an angle of 450 or more 27-1/2 in. (686 mm)Min. from the horizontal) 45 in.(1143 mm)Max. AN F NOZZLE MAY BE LOCATED ANYWHERE WITHIN THE GRID AN F NOZZLE MAY BE LOCATED ANYWHERE WITHIN THE GRID 45 in.(1143 mm) DIAGONAL FROM MAX AIM POINT 1 1 B t 45 in.(1143 mm) 45 In.(1143 mm) MAX MAX 2i NOZZLE LOCATION 4T OR MORE FROM a ,tom HORIZONTAL r r MIDPOINT OF 27.112Tn.— HAZARD AREA (699 mm)MIN AIM POINT y4 MIDPOINT OF f HAZARD AREA 14 In.(356 mm) 24-112 In. HAZARD AREA MAX (622 mm)MAX *t^--#r� DRIP BOARD DRIP BOARD 141n.(356 mm)MAX. 24-112 in.(622 mm)MAX. APPLIANCE AREA r --� 14 in.(356 mm)MAX �� FRONT VIEW SIDE VIEW Figure 3-5. 14 in.x 14 in. (356 mm x 356 mm) Deep Fat Fryer P/N 60-91271004M 39 April 2009 System Design 3-4.20 Griddle—Fiat Cooking g Surface (With or without Raised Ribs) Table 3-26.ADP Nozzle Coverage Area items parameters Maximum Hazard Area 30 in.x 42 in.(762 mm x 1067 mm) Nozzle Aim At a point 3 in. (76 mm)from the midpoint of hazard area Nozzle Location—any point on the perhueter of 13 In.(330 mm)Min. Appliance 48 in. (1219 mm)Max. Note.Positioning the nozzle directly over the appliance is not permitted. 48 in. (1219 mm) MAX. 1 301n. (762 mm) 13 m. MAX. (330 mm) MIN. TOP OF APPLIANCE AN POWT•3 in.(r6 mm)RADIUS FROM 42 in. THE MIDPOMr OF HAZARD AREA (1067 mm) MAX. Figure 3-22. Griddle-Flat Cooking Surface P/N 60-9127100-000 3-27 Apra 2009 a m; o, System Design 3-4.12 Four Burner Ranges (LPR). P/N B120024 top that has a back shelf or a The low proximity range top coverage provides protection for a range , T' broiler integral to the regular range. c, Table 3-16. LPR Nozzle Coverage Area—Four Burner Range A items Parameters M'�h�num Hazard�Lrea 24 in.x 24 in. (610 mm x 610 mm) Cidfwoit�t of hazard area Nozzle Aim Nozzle Location—I)iC�oae ion A in Figure 3-13 Refer to Table 3-17 Table 3-17. LPR Nozzle Parameters Burner teeing Centerline tea CeuterUne Nozzle Beek (Diumnsion A) (men ion B in figure 3.13) (ceutraUy Over the tange and under steel MrOflet) j Note: Shape of burner not important. 14 in. (356 mm) 16 in. (406 mm)Mim 20 qm (508 mm)Max. Between 12 in.and 14 in.(305 mm and 432 mm) 16 in(406 mm) Min. 17 in(432 mrn)Max. 254 min and 305 mm) 16 in. (406 Min) Between 10 in. and 12 in [ a e D(Nom E "A" k LPR E MAY BE LOCATED H( A. Tile HAZARD AREA.SEE TOP OF BURNERS TABLE FOR t4OZZLE HEOGHTS. ( Aaw POINT:MMDP"O T OF HAZARD AREA i� 24 in.(610 MM) DIMENSION"B" J� MAX.HAZARDfG AREA LENG rK !' 4 DIMENSION"B" �i - 2D AREA WNMAXF1 -----.-� � Figure 3-13. LPR Nozzle Coverage for a 4-Binxier Range (LPR) " r SEAL TIGHTS (TYP.)— ALL CONSTRUMON SHALLa E ►E 1/2"xt/2"TEE 13"x13" DUCT EET THE REQUIRRAIENTSOFTIPEw � 3-0" HOOD CODES OF STATEZ N ) g VENT PLUG i EXTENSION 9'-0" HOOD x VATE.A/_2 PA B.P AD">1 A ADP EXISTING - z ---- �2a z IFEE d� caNT�Rotk t —� --- i -. EI_ m 3 ADP -LOADP $ Z NOT! S( t 5 1S TAUT $= f ( I sORT1H=;OLI_ I ; —J o ————— ---- ---------� MI 1, H INSPECTION w 2. GO`v1P` c RG F IAAICE TESTING i I 4.0 i `_ �edo z & FI "INSPECTICIN GAL. ( ADP y ei` 0 w ALL VVORK Sf4ALL COMPLY=. _NyS May Requi a U CODES A_NOAPP � � STANDARDS x PULL 1 = " _MIN.TO EDGE STATION a OF HOOD ON I 36X28" it m BOTH SIDES �" 6 BURNER 36"x24" 15" o CONVECTION 1" GAS RANGE FLAT GRIDDLE TABLE ao o r VALVE OVEN w/SHELF m3 rtt1, 1[ i FRONT VIEW SCALE:%"=1'-O" AES MANUFACTURER. COMPONENTS: NOTES: £ SU RANGE GUARD:_RG 1.25 GAL._RG 2.5 GAL._(11RG 4 GAL._RG 6 GAL. x Fryers to have High Limit Control to shut off fuel at 425.' s � _ RANGE GUARD-RG 4.0 GALLON 1AA �_j- z Detectors shall be located over every piece of equipment. o�wws 3= _< Piping Material BLACK SCH 40 Max. Rise 12 MAX.FLOW POINTS= 12(9 USED) x The System installed as per manufacturers specs and the AHJ. ;�_ o< gygG TOTAL PIPE VOLUME NOT TO EXCEED 400 CUBIC INCHES Supply Pipe Size 1 2" Branch Pipe Size 1 2" DROPS 3L87 x The System has been installed as per UL300. MAX.PIPE LENGTH 132 Fr. x The following functions.to operate upon system discharge: w=4o °W�� !=g' Gas Valve Type: MECN Size 1" Manufacturer ASCO aR�€o3 gA * Supply air damper closes * Gas fuel shuts off in kitchenaw= �w �Ns SH Detector Temperature Rating: 360' 450' RG-4.0 GAL. CYLINDER #60-120003-001 * Exhaust fan remains on * Electric fuel shut off under hood Hood Size: 12'-0" Duct Size: 13"X13" CONTROL HEAD #B120099 *All systems to activate simultaneously in some hazard area. =2asY a� 8ffi� ADP NOZZLE #87-1 2001 1-001 * Fire Alarm shall activate. a, c EQUIPMENT SURFACE NOZZLE F NOZZLE 87-120012-001 x Manual Pull Station shall be located a minimum of 10 ft. from QTY. TIP#/QTY. LOCATIONS hood & a maximum of 20 ft. from hood and 4 ft from floor. ,o TYPE AREA HEIGHTS LPR NOZZLE #87-120024-001 L DUCT 1 13"x13" rPj 0°-6" 0"-6"IN OPENING 36Q LINK WK-282664-000 x All fuel sources are GAS unless otherwise noted. � �y a PLENUM 1 12'-0".... 0"-6° FROM END OF PLENUM 450' LINK #WK-282663-000 �� V s BURNER RANGE 1 36"x28" 16"-20" CENTER LINK HOUSING804548 CODE REFERENCES_(TYPE 1 GREASE HOOD) z� y U MANUAL RELEASE B875572 X a o FLAT GRIDDLE 1 36"x24" 13"-48" NV PERMEIER A1✓WiNlf 3"CTR. THIS INSTALLATION IS IN CONFORMANCE WITH: �y `o FRYER 1 18"xl8" 27"-45" 45'TO 90' 1" GAS VALVE #13120072 - NFPA 17A - 2017 O -a 9 O n - NFPA 10 - 2018 0 - - NYS MECHANICAL CODE 506,507,508 r -ASTM E2336 - 2016 a- ;-4 - THE BUILDING AND FIRE CODES OF NEW YORK STATE- 2020 O 3 o ¢� NOTE: v - _ - COOKING EQUIPMENT CHANGE C Q} ® 7�1 z a A FIRE EXTINGUISHER WITH A MINIMUM RATING - NO PIPING REQUIRED HOOD EXTENSION IS {6 fD ° OF CLASS K MUST BE INSTALLED WITHIN THE - SAME CONTROL HEAD L STAINLESS STEEL TYPE 1 HOOD, VICINITY OF THE COOKING AREA. - SAME TANK(S) { a