Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
52730-Z
hoy��of S°&ryo`o Town of Southold * P.O. Box 1179 " 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46914 Date: 03/17/2026 THIS CERTIFIES that the building AS BUILT HVAC Location of Property: 920 Pine Neck Rd Southold, NY 11971 Sec/Block/Lot: 70.-8-19 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 01/29/2026 Pursuant to which Building Permit No. 52730 and dated: 03/09/2026 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "As built" central air conditioning as applied for. The certificate is issued to: Mark Lesko ,Karen Lesko Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 52730, 3/13/2026 PLUMBERS CERTIFICATION: Au oriz ignature lot so�ry TOWN OF SOUTHOLD BUILDING DEPARTMENT N Y SOUTHOLD, NY Ulm BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52730 Date: 03/09/2026 Permission is hereby granted to: Mark J Lesko 29 Upper Sheep Pasture Rd East Setauket, NY 11733 To: legalize "as built"central air conditioning as applied for. Premises Located at: 920 Pine Neck Rd, Southold, NY 11971 SCTM# 70.-8-19 Pursuant to application dated 01/29/2026 and approved by the Building Inspector. To expire on 03/08/2028. Contractors: Required Inspections: Fees: As Built HVAC $500.00 C -RESIDENTIAL $100.00 Total $600.00 Building Inspector SO�r�olo Town Hall Annex Telephone(631)765-1802 54375 Main Road N P.O.Box 1179 � �Q Southold,New York 11971-0959 � COUNTY,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Mark J Lesko Address: 920 Pine Neck Rd city: Southold St: NY zip: 11971 Building Permit#: 52730 Section: 70 Block: $ Lot: 19 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Electrician: AS BUILT License No: SITE DETAILS Office Use Only Commercial Indoor X Basement Service Solar Residential X Outdoor X 1st Floor Pool Battery Storage As-built X Renovation 2nd Floor Hot Tub EV Charger New Addition Attic X Spa Generator Survey X I Mezzanine Garagel IDock INVENTORY Service 1 ph In-wall Heater Recpt Ceiling Fixtures Smoke Detectors 2 Pump Service 3 ph Hot Water GFCI Recpt Wall Fixtures CO Detectors Heater Main Panel A/C Condenser 1 Single Recpt RecessdFixtures Combo Smoke/CO 2 Transformer Sub Panel A/C Blower 1 Range Recpt Ceiling Fan Heat Detectors Salt Gen Transfer Switch Mini Split Dryer Recpt UC Lights Fridge AutoCover ARC Blower Heads Switches Pucks Lights Dishwasher Mini Fridge GFI SepticDisconnect Emrgency Strobe 4'LED Microwave Garbage Disp. ARC/GFI ERV Exit Lights Bath Exhaust Hood Dehumidifier Other Equipment: Notes: " AS BUILT NO VISUAL DEFECTS " HVAC and Smokes Inspector Signature: Date: March 13, 2026 OFSO(/lh°� ✓✓ * TOWN OF SOUTHOLD BUILDING DEPT. courm, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL t4S r 6Vi 1A C [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]. RENTAL REMARKS: J DATE INSPECTOR SOUly�lo 7 WSOUTHOLD T A 5 TO�N f B DING DEPT. courmN�'' 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) � ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: !22 ) ! uf- f� r cy f n r .� �Q n� DATE INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS J FOUNDATION (1ST) ---------------------------------- 'IC FOUNDATION (2ND) 0 ROUGH FRAMING& m , PLUMBING co op JJ r INSULATION PER N.Y. STATE ENERGY CODE G 1 c O e C8 FINAL ADDITIONAL COMMENTS r il� boo®= :B, P+co re- -of p o � Z m W >1 i b Ao - �✓ y C O x x d b 6�®gUfFOt �b� TOWN OF SOUTHOLD ❑BUILDING DEPARTMENT #'Q Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only &Z PERMIT NO. .� Building Inspector: ?_ �_ JAN 2 9 2026 Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,an OwnerR Authorization form(Page 2)shall be completed. Date:1/29/2026 OWNER(S)OF PROPERTY: Name:MARK J. LESKO AND KAREN E. LESKO I SCTM #1000-070.00-08.00-019.000 ProjectAddress:920 PINE NECK ROAD, SOUTHOLD, NY 11971 Phone#:631-682-9666 I Email:MARKLESKO1 @YAHOO.COM Mailing Address:29 UPPER SHEEP PASTURE ROAD, EAST SETAUKET, NY 11733 CONTACT PERSON: Name:MARTIN D. FINNEGAN / FINNEGAN LAW, P.C. Mailing Address: PO BOX 1452, 13250 MAIN ROAD, MATTITUCK, NY 11952 Phone#:631 -315-6070 Email:MFINNEGAN @ NORTH FORK.LAW DESIGN PROFESSIONAL INFORMATION: Name: N/A Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name:N/A Mailing Address: Phone#: FM711- DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated cost of Project: D Other AS-BUILT CENTRALAIR CONDITIONING $N/A Will the lot be re-graded? ❑Yes ©No Will excess fill be removed from premises? ❑Yes No 1 PROPERTY INFORMATION Existing use of property:SINGLE-FAMILY DWELLING Intended use of property:SAME Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R-40 I this property? ❑Yes ©No IF YES, PROVIDE A COPY. B Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(prI name): R INN EGAN ®Authorized Agent ❑Owner Signature of Applicant: Date: 1/29/2026 STATE OF NEW YORK) SS: COUNTY OF SUFFOLK ) MARTIN D. FI N N EGAN being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the AGENT/ATTORNEY (Contractor,Agent, Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of January , 2026 Notary Public ANNALISE OUELLETTE PROPERTY OWNER AUTHORIZATION NOTARY PUBLIC-STATE OF NEW YOR 457 (Where the applicant is not the owner) No.d i Suffol 'Co Qualified in Suffolk'County My Commission Expires 09-28-2028 I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner3 Signature Date Print OwnerA Name 2 Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) 1, MARK J.LESKO AND KAREN E. LESKO residing at 29 UPPER SHEEP PASTURE ROAD, (Print property owner's name) (Mailing Address) EAST SETAUKET, NY 11733 do hereby authorize MARTIN D. FINNEGAN (Agent) &FINNEGAN LAW, P.C. to apply on my behalf to the Southold Building Department. Mark J. e o (Date) Karen E. Lesko BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD } 34 �{ Town Hall Annex - 54375 Main Road - PO Box 1179 40 { Southold New York 11971-0959 `4-1 �����;% Telephone (631) 765-1802 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 3/11/2026 Company Name: AS-BUILT Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: MARK J. LESKO AND KAREN E. LESKO Address: 920 PINE NECK ROAD, SOUTHOLD, NY 11971 Cross Street: Phone No.: 631-682-9666 Bldg.Permit#: ,,5-2,- 3O email: MARKLESK01 @YAHOO.COM Tax Map District: 1000 Section: 070.00 Block: 08.00 Lot: 019.000 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): AS-BUILT CENTRAL AIR CONDITIONING Square Footage: Circle All That Apply: Is job ready for inspection?: 0 YES ❑ NO ❑Rough In 0 Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals M 1 F12 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION c-e l (o2 d P-47- 52-7 c�0 j= BUILDING DEPARTMENT- Electrical Inspector y�0�® rC� TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 '`` Southold, New York 11971-0959 p� Telephone (631) 765-1802 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 3/11/2026 Company Name: AS-BUILT Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: MARK J. LESKO AND KAREN E. LESKO Address: 920 PINE NECK ROAD, SOUTHOLD, NY 11971 Cross Street: Phone No.: 631-682-9666 Bldg.Permit #: ,,5-2,-7 &0 email: MARKLESK01 @YAHOO.COM Tax Map District: 1000 Section: 070.00 Block: 08.00 Lot: 019.000 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): AS-BUILT CENTRAL AIR CONDITIONING Square Footage: Circle All That Apply: Is job ready for inspection?: YES ❑ NO [—]Rough In ✓0 Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame' Pole Work done on Service? MY N Additional Information: PAYMENT DUE WITH APPLICATION 3 C_ILA Cc Z PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. W/D PanelPump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used Comments Certifications indicated hereon signify that this-plat of the property depicted hereon was made in accordance with the existing Code of Practice for land Surveyors adopted by the New,York-:State Association of Professional land Surveyors. This certification is only,for the lands depicted hereon and is not Certification of title,zoning,or freedom of encumbrances. Said certifications shall run only:to the persons and/or entities listed hereon and are not transferable to additional persons,entities or subsequent owners. PINE NECK ROAD S 71031'30., E S S3•4710 E 60J3 45•S6 W �' ° Z 222.59' o } a a Q I � • , .j s I I (n o z m Z N o N _ 0 � I O R 0 �13.9' r QI 00 r l I N a 6.3' 6 11.5' a Q O I 22:5 � 1 STORY " A/o .I � UNIT x to NE g20 CON X CRETE' Q W 39.0' 3 t- FUEL r' I;{Zaq'F.AVER p TANK 0 M I I•CONCRE 1E N 25.3' 21 15. I I Q. r Z N I SHED a I I w 2 ut a REBAR FOUND- — ul FE FE 0.2'N . IIA S— �S 1 FE FE .�� FE �F��� 2.1'S, 0 1.a'S FE gTOQKADE' E .STOCKADE 0.8'S 1.8S FENCE E F�OO ADE _ FE FENCE 15'5 FENCE .53�47,1.0„ N 71*31#30" W 52.Sg• 73.71' MAP OF SECTION ONE, FAIRVIEW PARK AT SOUTHOLD UA: SURVEY VIEW; SURVEY The offsets,or dimensions shown from structures to the property lines are for a specific purpose and use,and therefore,are not intended to guide in the,erection offences,retaining walls; pool's,patios,planting areas,additions to buildings and any ;other construction. 'Subsurface and environmental conditions were not examined or considered as a,part of`this;survey. Easemenfs, Rights-af-Way of record,if any,,are not shown.Property corner monuments were not placed as a part of Ibis survey. © 2022 BBV PC Barrett Tax Map: DISTRICT 1000 SECTION 70 BLOCK 8 LOT 19 ` Bonacd & Map of: DESCRIBED'PROPERTY Unauthorized alteration or addition to (EB this survey is a violation of Vion Van Weele, PC __ i209 of New York Slot duc a lo Map Lot: - Map Block: w Engineers . Surveyors Planners 175A Commerce Drive Hauppauge;,NY 11788 Filed: ,--- No.: --- County: 'SUFF.OLK T 631.435.1111 F 63.1.435.1022 www.66vpc.com. Situate:`.SOUTHOLD,TOWN OF SOUTHOLD. Certified to: Title No.: 7404-013614 Revision By Date Copies of this survey mop not beer- MARK J.LESKO&KAREN E.LESKO ing the land surveyor's embossed FIDELITY NATIONAL TITLE INSURANCE COMPANY seol:ond signature shall not to be a true and valid copy Surve ed 6 i B.S. Drafted 6 J.F. Checked: : C.W. project No:' A220114 Scale: 1"= 30' Date: MARCH 20 2022 K:\Da22\A2201145DWG\A220114.dwg,TIFLE,'3/23/2022 8:42:08,AM,Barrett,Bonacd&.Van Weete./CW AP PR UED AS NOTED DATE x ' B.P.#, - FEE V BY NOTIFY BUILDING DEPARTMENT AT 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: OCCUPANCY OR 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE USE IS UNL AWFUL 2. ROUGH-FRAMING&PLUMBING /'1�r 3. INSULATION WITHOUT CERTIFICATE 4. FINAL-CONSTRUCTION MUST OF OCCUPANCY BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE &TOWN CODES AS REQUIRED/,DEC ONDITIONS OF ELECTRICAL. TOWNZBA INSPECTION REQUIRED TOWN PLANNING BOARD _._._ TOWN TRUSTEES HPC �itK1AL NO . / No DE SERIE W202334847 OUTDOOR USE/ v UTILISATION EN EXTRIEURE COMPRESSOR CODE / CODES DE COMPRESSEUR 970219707 702/9707 VOLTS 2O8 / 30 PHAS E. 1 HERTZ 60 COMPRESSOR/ COMPRESSEUR R. L.A . 14 . 1/14. 1 L. R.A. 67.9 OUTDOOR FAN MOTOR/ MOTEUR VENTI L . EXT . F. L. A. 0. 8(840) H. P. 1/6 MIN . SUPPLY CIRCUIT AMPACITY/ 19/19 A '— COURANT ADMISSABLE D ' ALIM. MIN. MAX. FUSE OR CKT . BKR. SIZE*/ 30/30 A CAL. MAX . DE FUSIBLE/DISJ* MIN . FUSE OR CKT . BRK. SIZE*/ CAL. MIN . DE FUSIBLE/DISJ* 25/25 A DESIGN PRESSURE HIGH/ PRESSION NOMINALE HAUTE 450 PSIG/3102 kPa _ DESIGN PRESSURE LOW/ PRESSION NOMINALE BASSE 250 PSIG/1723 kPa OUTDOOR UNITS FACTORY CHARGE/ R410A CHARGE USINE D ' UNITES EXTERIEUR 120 oz/34029 R410A TOTAL SYSTEM CHARGE/ CHARGE TOTALE DU SYSTEME 01 SEE INSTRUCTIONS INSIDE ACCESS PANEL / s 0 VOIR LES CHARGE INSTRUCTIONS d L' INTtRIEUR DU PANNEAU D'ACCES '1 N RHEEM SALES COMPANY -� FORT SMITH , ARKANSAS 07' ASSEMBLED IV IN co ACR TYPE BREAKER FOR U.S.A./ MEXICO N DISJONCTEUR DIFFERENTIEL IPX4 cp 1111111111111111111111111111 IIIII1I'lll'lll'Ifllll'll1'I y\ f 16, lilt t 1 ■ 1 -s a r n d a s