Loading...
HomeMy WebLinkAbout52659-Z of SOUlyy!° Town of Southold * * P.O. Box 1179 53095 Main Rd NV, Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46881 Date: 03/05/2026 THIS CERTIFIES that the building GENERATOR Location of Property: 60 George Rd New Suffolk, NY 11956 See/Block/Lot: 117.4-1 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 12/18/2025 Pursuant to which Building Permit No. 52659 and dated: 02/09/2026 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Generator accessory to an existing single-family dwelling as applied for per manufacturers specifications. The certificate is issued to: James Balzaretti , Denise Balzaretti Of the aforesaid building". SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: AE260210-83050 2/16/2026 PLUMBERS CERTIFICATION: uth z S1 nature �NOFSoo TOWN OF SOUTHOLD BUILDING DEPARTMENT • k' SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52659 Date: 02/09/2026 Permission is hereby granted to: James E Balzaretti 680 Sterling Rd Cutchogue, NY 11935 To: Install a generator accessory to an existing single-family dwelling as applied for per manufacturers specifications. Premises Located at: 60 George Rd, New Suffolk, NY 11956 SCTM# 117.-4-1 Pursuant to application dated 12/18/2025 and approved by the Building Inspector. To expire on 02/09/2028. Contractors: Required Inspections: Fees: GENERATOR $125.00 CO Accessory $100.00 Total $225.00 Lj� Building Inspector ALLIANCE ELECTRICAL INSPECTIONS LIMITED 707 HYMAN AVENUE; WEST ISLIP, NY 11795 " SECTION: 117 BLOCK: 4 LOT: 1 CERTIFICATE NUM: AE260210-830SO BUILDING PERMIT NUMBER: 52659 CERTIFICATE DATE: 02/16/2026 FINAL RESIDENTIAL ELECTRICAL CERTIFICATE THIS CERTIFIES THAT ONLY.THE ELECTRICAL EQUIPMENT AS DESCRIBED AND;INTRODUCED BY THE APPLICANT NAMED ON THE ABOVE CERTIFICATE NUMBER AT THE PREMISES OF: JAMES E BALZARETTI,60 GEORGE ROAD ,SOUTHOLD,NY 11956 INSPECTION WAS CONDUCTED ON 02/16/2026 AND WAS FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRICAL CODE AND/OR NEW YORK STATE APPLICABLE CODE AT THE TIME"OF CONSTRUCfION.IN THE FOLLOWING LOCATIONS:. Basement,Outside 1 Generator.14"Kw 1 Transfer Switch Auto 200A j APPLICANT: NEUBAUER ELECTRIC LICENSE NUMBER:3867 ME SUFFOLK COUNTY r= ' 407 B LEXINGTON AVENUE ,WEST BABYLON,NY 11704 i C �:. CATALIN DUMITRU PRESIDENT 1 631-539-'6055 ALAN GAGNON VICE PRESIDENT S16-248-0820 IS'CERTIFICATE MAY NOT BE ALTERED IN ANYWAY AND IS VAUD BY THE PRESENCE OF A RAISED SEAL AT THE LOCATION INDICATED i, . - THIS CERTIFICATE IS VALID FOR ONE YEAR FROM THE DATE OF ISSUANCE . pF SOUTyOlo - - ----- # # TOWN OF SOUTHOLD BUILDING DEPT. 'oum,��',� 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ],WSULATION/CAULKING [ ] FRAMING /STRAPPING [,/] FINAL 6&WA-V [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]. RENTAL REMARKS: t C� DATE to INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) ------------------------------------ ce C FOUNDATION (2ND) � z � o a ROUGH FRAMING& PLUMBING t0 F 1 I r INSULATION PER N.Y. STATE ENERGY CODE 0 , i FINAL ADDITIONAL COMMENTS c� 0 �z ,m X mx z x v b oyogpFF4(K G,,r�., TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 ;oy • o� '. Te-lephone.,(631) 765-1802 Fax(631) 765-9502 https //www southoldtownny.>;ov - Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. w Building Inspector: 1�a A cations•and forms must be filled out in therrentirety Incomplete DEC applicatiipp !,not be accepted Where the Applicantis not the owner,an Owner'sAuthorization"form(Page2)shall be completed eci ng 't .Etr_. . �u sic Ic;3U�f`�•r •��e,�� gas$ Date a� '' t .�� r . `� _ T 1. �._s ,.✓.. >a�.� ,.l-..xw. .'a . ..�� Name: �m � .=,.n. :,.. SCTM # 1000- f 17 -4 -1 tS rtjq: RLZ17 Project Address: �Q at IIIO ?a(fh AA14 SQFFOCK 1.1 a S Phone#: 514 _220_ I G9 Email: r0 1 V e Mailing Address G a 2L N V' i u t CONTACT PERSON :z a{., : , , Name: --TrI Mailing Address: `►$D STD A) C. V I GUL-. I i1��135 T Email 11 Phone#: r 1 C • C C DESrGN PIiQFESStONAL fNF0 AA IUN Name: - �� QcE, I(i So2 Lit GS7 Mailing Address: .ZS k 7 ` Phone# 43t g�� !.3� p Email ,e ��• $ C&n Name: P19JL AVE � '! 41 60 00A 9-20111T!151 AJ Mailing Address: /*,3� 9�rQ �b GC &J so &,A IVY t I 7 / Phone#: C Email: �'� � � • 0� DES,CRIPT((QN C►1f'PRQPOSED CaNSTRUCTION _ ❑'New`Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: Qbther IT (PPLI �']DA) fok- atrITDODQ 6t1UCI '�( *� $ Will the lot be re-graded? ❑Yes El No Will excess fill be removed from premises? ❑Yes ❑No 1 ., PROPERTY I.NFORNIATION ,3 i Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants, and restrictions with respect to this property? ❑Yes [ /o IF YES, PROVIDE A COPY. CYCheCIC BOX After Rea'ding The owner/contractorjdes�gn professional�s responsible-for att drainage acid stornn water issues as{provided by Chapter 2d6 of the Touvn Code APPLICATION 15 HEREBY MADE to the Building Department for.the issuance of a Building Permit pursuant to tFie Budding`zone, Ordinance efth�Toxin of Southold,Suffolk,County,New York and other applicable laws,Ordinances or""Regulations;for the construction of NO dln s additions,alteratiofis or for removal or demolition as herem,descr�bed The a' hcant a Tees to com I with all a` licable'laws ordinances buildin Co .. PP B P Y , . ,PP e,.. . g housing code and regult�ons and to admituthoraed inspectors on premises and m buildmg(s),for necessary inspections False statements made herein are, ` punishable as a Class.Afim�sdeme nor b`rstraittto Section 210 S of ffie New York State penal law z ; , _. Application Submitted By(print name): —rn ❑Authorized Agent CL7O vner t Signature of Applicant: Date: 12q�� , ZS p CONNIE BUNCH STATE OF NEW YORK) Notary Public,State of New York SS: No.-.01 BU6185050 Qualified In Suffolk.bounty COUNTY OF ) Commission ExplresAprll 14,2�� being duly sworn, deposes and says that(s)he..is the applicant (Name of individua'I signing contract) above named,^ (S)he is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed.the:said work acid to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this Aay of \ 2007 Notary Public PROPERTY OWNER AUTHORIZATIONS (Where the applicant is not the owner) residing at do hereby'authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 r ��o�uffptR,�O BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 o . Southold, New York 11971-0959 Telephone (631) 765-1802 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date: VS Company Name: IV E Uk3 i} Ue CL,LCT,•!L /,C.. Electrician's Name: Mal 1Je: u 8A UEYZ. License No.: 3 (, /tn.� Elec. email: heU6ave. aieC�e1 � m Elec. Phone No: 3 _ Zd`f-4��5 ❑1 request an email copy of.-Certificate oT Compliance Elec. Address.: tip. $ C -oA) i9I/+:sAlt ? 6 #J Y Q d JOB SITE INFORMATION (All Information Required) Name: dA-N1Es 8JJL?-AaL"7T7 Address: 4ui .Sur-r-gue 0 Cross Street: 4 ePr 14.r H ul o Phone No.: S!G- 22 Bldg.Permit#:�J�ai (p_S� email llive-. coA'1 Tax Map District: 1000 Section: / Block: Lot: / BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): PC-YaA t r OPPt i C&7-1N F-o(L- AW aur0002 Gz-:7V �vt Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service[]Fire Reconnect[]Flood Reconnect❑Service Reconnect[:]Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N" Additional Information: PAYMENT DUE WITH APPLICATION i PERMIT# Address: Switches Outlets G F I's Surface Sconces H H's UC Lts Tridge HW POOL' Panel Fans Mini Fr. W/D Pump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator*..' Salt Gen. Grb•Dis Water Bond Carbdn , M.icro , . Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo . %Cooktop Minisplit Blower AC AH Hood Blower , 'Service Amps Have Used Sub Amps Have Used Comments S.C.T.M.# DISTRICT 1000 SECTION 117 BLOCK 4 LOT 1 #R-24-1280 r O O 0— led L e Moot �.RIDW eFNelw1D ., ,tee, I I O 1.M OES:WOM OWL HUM DOOROW FMWY MEOW OOMY DDMO"OF WK OLY.0.0 a 2 M DMM WMM NO OVMWM CWW KnM ME MAIGOG IS RUM AO TW A 9ft DC FFAM TO M 3= to um 7,y 1 rWO1fFF>DIMOM MORWOMOMM4TODE WOWOUVOW1MS FD ` M -111'3WL OE Nmm IOMMMODm30WLn1QftL mT=mmO s cum .:1+...... t _ a m m=nm SURE NMEO=V M MOM WNt ff M m76 Art OUNE WLEf FR So 1W ;:;: ` ` •r-- N8iD5fFD GPEwa UP ID 4 Sm006 PAIL One Em OD Wm aN OIOIRt ;[;�:r (»iDODn aras u DYW�D �' O '+'I'`i FA 2'If 11 ,+ w IDRNDI mu mv,m • •�17771ii OONM LAF Sven LNo N/r OF D N eL MARC A NOW= ARff La mu A. _ K WRIUMu I 1 �{\fO NiCH t 0 � � a OA1W Sr�EFOF NE`Nv. I MawtD IL W70 ALA NN l8:(0/1°°I O #.FujiClean USA 7--s0000 ZONED R-40 NON-Cowan"LOT FAOW YARD 3W FIR SECOND R1'FRpN VM 20.IN SM WTDk DOWN NO REAR YARD IMD. ' O O ' IRX MW FLOW AM 2.100 Sr.♦CUAX.205."L437 SF.WX �_.--..---- MAP/36103CO501H FLOOD ZONE% THE WATEN Wftr,,NELL%DRYNUW AND(SOLI LOGROYS WOW ARE FROM MO OSSWW OW AND OR DATA WrAM FAOY 07MM AREA 12.655.52 SQ.FT.or 0.29 BCR.f:$_ ___,.._..._.__ QLYATMN LiLDAD NAV7l88 1/AOETFO®ALTFR.IiAW LR AtmIJA7Y>o TKS'SGg{!Y'ts A�MOAA111`0�S4ERO-bdoYi OE Am RFR sum FDOTAT LAE Comm OF m NRIEr NAP NOF ffiDt•A7 OE UIO SWI 11 .SFAL.SNAL,N I...TO E A VALD 7RIE OO°Y. OORANIfa/AO.I7ED Ii7EOY tiLAL RW Or.r TO DE FO W FOR WWI DE aRWY LSFRWARW AFO W MY MWIF NO DE ONE LOIFANY,g711 MUNM AWWr APD LSW IOMU MF O LEW LEEEM AND ID DE A�OIEYS 6 DEJ( AmDN{f<I(,WARAAEP:- -NO_(FRAFRIRA9L IIE OPS815 OF W®M9Q6 bMDW f011R/tW M''AIf6OD1'IPE4 IO TIE AIR'FOR A FSW7C RA10W AM WL 7/C<ffOE DEY M6 NOr M M M NONAON TIE MQVtW LMES OF 110 MW PC DEOIM OF W=AOOD01'AL SDIOCNES OR AM DDRN AMROW3mNm 94SEMM AWAR AVSLWAW SORPOR E9 MEOWED W WECOMED ARE Atli WARANIQD LINS4%1/9C41r E WOW W TIE FRDLSES AT DE THE Or SWWV O aianDESCRIBED PROPERTY CERTIFIED T0: AM JES SALZARETTI• - - 0 DI� w0r DENISE BALZAREM; i FOLD: Wy? -'-- --- _ O aRwha AT.NEW SUF'FOLK TM o5 SOUTHOLD _ .. MENNNIMI �.n,F y troYt:11TT[LNIf RURYRYINO,F7JC SUFFdJ(COUNTY,NEW YOf6( yi B1 FlotatGDna1 Innd 81DYylry.Da DbfO REVISED 09-23-24 _ P.O.8OZ 163�Q1msDEOD,Ntnr 1.4 11W1 REVISED 09-16-24 ME 419-69 SCAM 1'-JO' DAMJUNE 12,202 Krs a%= mom(NdowtuD PAZ(03)we-aw 4. OSEPTIC P�v` 01 3� �f U.P. owa 601. 'I W1'fC(L UAfo O p 150'TFi4 6/ W 150 v. R W V / v.M. 72 Sol E Ro � � S o W.V. o�orrF AD w ou.P. 2 ? W.V. •� W o �3S oor s S x o EXISTING 1 STY FRAME DWELLING NCO) - C #50 PR [�O�f FFL 12.9 r $ 1 :.I•:•:::::•: •: :.:. OP.Cp - TO BE DEMOLISHED v+ elN . .. ..:.:•..'.::44.3• Of? : :::•::: _.• .• CN ::f:}:.... DWELLING taf� O 1� (rj-Do Q 2 :i;.'•:[•r:: 2 gn;4�f=..:.:i:::: N' W/WELL WATER GCNIc- 2 Oj WELL LAND N F OF 1 WILLIAM BLANCHARD DWELUNGs DfC/t Sir W/PUBUC WATER, - 150' w CRY 1 1 L.G. �O 3 Z 0851a, L.G. 14 4M 2 Cr 2'SCH40 PVC VENT PIPE A ELECTRIC AND AIR SUPPLY HOSE TOOWTS :y Y D LrpRl Lj CONTROL PANELANDAIR PUMP •:,�::„ ` jE�FAfOL �I 4 1.4r - ELEC.SERVICE TO CONTROL PANEL ••..,.-pP"":':"" •C �„ GF f:::...... ... .�+""_��'t i EXISTING SANITARY TO BE 5.0':. '::�•:' :' i;�::' P }:::• :s: ABANDONED AND BACKFILLED TO BE REMOVED o•.• SO'�:•Z8'~l:•::•:... .. •0 OSEp%•i:;�.� <'••'4r WITH CLEAN COARSE SAND IJ.Or K1.6"b T ' ` '^ :a :1'f+'` AYtf:: '•�-f��c`ts5'f ir —WATER EL 1.1 72 SO' 6.0' 6t?00, os's R LAND N/F OF MARIF .I IIK:KFRC(NJ /w Site Selection and Preparation Fire Prevention prevention, but, also to provide sufficient The generator must be installed at a safe dis- room for removing front and end panels for tance away from• combustible.materials., . maintenance purposes. 'Engine,alternator, and exhaust system corn- IMPORTANT NOTE:The diagram provided ponents become very hot during operation, represents general guidelines,and are not Fire risk increases if unit is not correctly ven- all inclusive.A unit placed in accordance tilated, is not correctly maintained, operates -with NFPA requirernents,Including the off- too close to combustible materials, or if fuel set reduction validated through testing by leaks exist.Also, accumulations of flamma- SWRI,may still allow CO within the strut- ble debris .within or outside the,generator enclosure,may ignite. . ture. Unit may need to be,instalied,farther - from the structure than the NFPA requires. Distance Requirements See ',•. Minimum clearances otust be maintained around the.generator.enclo- sure.These clearances are primarily for fire C nF �•'.?i/-'. --i '�GJ tom'"'\� i':iw'� " I!a J yCC e Figure 3-2.Generator Distance Requirements . ID Description Definition Front.and en' Minimum clearance from the front and ends.of generator must bV3 ft l clearance 1(0.91 m).This includes shrubs,bushes,and trees. . 1%1,n'.mum clearance from the rear of the generator must be 18 in(457) jn 1--Rea, `:e=t 3ncei I udn).This ind6dcs shrubs,bushes,and trees. ............- /�Q 130 operable vnndavls,doors,vents,window weiis,or openings in the wall l Y C t Ian v\rndo:s,vents, re permitted closer-to any point of the generator than what is permitted V i d openings by locally adopted codes.See Fire Codes,Standards,and Guidelines for more information. The generator should not be placed closer to existing'walls than what is D J Er.',st'ng wall permitted by locally adopted codes,while abiding-by the front;end,and I i rear clearance's-(A, B)listed above. Installation Guidelines for 60 Hz Air-Cooled Generators .. 15 ' r , Site Selection and Preparation A remavable_barrier(non-permanent;without footings)installed as a E Reniavable visual surround. . fence Removable fence panels cannot be placed within 3 ft(0.91 m)of the generafns: Overhead I Structures.overhangs:or projections from a wall above the engine F generator or,above,the.front,end,and rear clearances(A,B)must be at clearance least 5 fl(1.52 m)vertical distance from the top'of the engine generator. Maneuvering space around generator for performing routine maintenance G Maintenanceand tasks such as'batteryreplacement and engine service.Do not attempt to servicing con ceal-generatarwith shrubs,bushes,or plants.See NEC Article 110.26 for more information. Fife Codes,Standards,and The test criteria-was to,determine the worst ' Guidelines case fire scenario within the generator and o, determine the ignitability of Items outside the Generator installation must comply strictly engine enclosure,at various distances.The with ICC IFGC, NFPA 37, NFPA 54, NFPA enclosure Is constructed of non-combustible 58, and NFPA 70 standards. These stan- materials, and the results and conclusions dards prescribe the minimum safe clear- from the independent testing lab indicated antes around and above the generator that any fire within the engine- generator enclosure. enclosure would not pose any ignition risk to NFPA 37 nearby combustibles or structures. NFPA 37 is the National Fire Protection Based on this testing and the requirements of Association's (NFPA)standard for,the instal- NFPA 37,Sec 4.1.4,the guidelines for instal- lation and use of stationary.combustion instal- lation of the generators listed above are engines.Its requirements limit the spacing of changed to 18 in (457 mm) from the back an engine generator to a minimum of 5 ft('1.5 side of the generator and 3 ft(Q. t m) from, m)from an opening in a structure or a strut- the front and ends of the generatorais. This a sf et ture having combustible walls, and require lure having combustible walls. This offset the engine generator to be located where it is reduction does not apply to clearances from readily accessible for maintenance, repair, openings in the structure. and first responders. The standard contains For adequate maintenance and airflow clear- an exception which allows an engine genera- ante, the area above the generator should for to be closer to a combustible wall when be at least 5 ft(1.52 m)with a minimum of 3 it approved testing demonstrates a fire origi- (0.91 m) at the front and ends of the enclo- nating at the engine does riot ignite the com- sure. This Includes trees, shrubs, and bustible structure. bushes, vegetation not in compliance with these clearance parameters could-obstruct air flow. In addition, exhaust fumes from the generator could inhibit plant growth.See Fig- ure 3-2 and the accompanying descriptions. `* e y�'use ar•wmw„a�..n 'elm m a""r - Generator Maintenance"M 3 r"oua YAU- IUi!6 CO 04N.Y171--�'-- `m 01 Regular maintenance is crucial for minimiz- -� i WM 7 go wVtYw----- ing exhaust emissions and reducing the risk . =a='C=°fmw PC of fire orequip ment failure.u For example: p _ A dirty air filter or low engine oil level may Figure 3-3.Southwest Research Institute cause engine to overheat. Marking •.;Incorrect ,spark plug gaps may cause NOTE: The Southwest Research' Institute engine backfiring and incomplete (SwRl� is a nationally recognized third party combustion. testing and listing agency. SwRI testing IMPORTANT NOTE:See Maintenance sec- certifies a reduction of the minimum clearance tion of generator owner's manual to view a from the engine generator to a structure table of scheduled maintenance tasks and having combustible walls. procedures.Perform all maintenance tasks as directed. is Installation Guidelines for66 Hz Air-Cooled Generators � J Site Selection and Preparation t Fresh Air for Ventilation and base pad. Follow all applicable codes if a Cooling concrete base pad is required. Verify any base pad meets or exceeds local codes and Install unit where air inlet and outlet openings requirements for wind ratings. will not become obstructed by leaves,grass, snow,etc.If prevailing winds will cause blow- See Figure 3-4. Prepare a rectangular area ing or drifting, consider using a windbreak at approximately 5 in (127 mm) thick (A) and a safe distance to protect the unit. approximately 3 in (76.2 mm) longer and wider(B) than the footprint of the generator on all sides when using pea gravel or Water Ingress Avoidance crushed stone. • Select a location on high ground where water levels will not rise and Cloud the — generator.This unit should not operate in,or be subjected to,standing water. • Install unit where rain gutter downspouts, -- roof run-off, landscape irrigation, water sprinklers, or sump pump discharge does not flood unit or spray enclosure, including O D 0 any air inlet or outlet openings. • Excess moisture can cause excess corrosion and decrease life expectancy of IAA the unit. 1`1_._._ • • ' aoaass Proximity t0 Utilities Figure 3-4.Pea Gravel or Crushed Stone • Contact local utility providers and verify Concrete base pads must be appropriately proposed site selection meets all required sized in accordance with national, state, or utility placement requirements before local building codes. installation. This could affect warranty Verify surface where generator will be coverage. mounted is compacted, leveled, and will not • Remember, laws and or codes may erode over time. Generator must be level regulate distance and location of unit to within 0.5 in(13 mm)all around. specific utilities. • It is recommended to pick a location where Recommended concrete base pads: the generator is as close as possible to the 10000007852 — 3 in (76.2 mm), transfer switch and the fuel supply, while 10000007848—4 in(102 mm). verifying the site location conforms to the rest of the Site Selection section. Placement on Roofs, Pistfo rms, Verify Wi-Fi Range(If Applicable) and Other Supporting Structures See wireless communication accessory man- Where required to place generator on a roof, ual shipped with the unit if planning to use platform,deck,or other supporting structure, the Wi-Fi feature. generator must be placed in accordance with the requirements in NFPA 37i Section 4.1.3. Transportation see 9=ife Codes,Standards,and Guidelines RecU:r;mendations for permissible clearance reductions.Surface Use a suitable cart or equipment to carry beneath the generator and beyond must be generator, including wooden pallet,to instal- noncombustible to a minimum distance of 12 lation site.Place cardboard between cart and In(30.5 cm).Contact local building inspection generator to prevent any damage or department or fire department to determine scratches to generator. which noncombustible materials are Do not lift, carry. or move generator by approved for installation. grasping the'czners.Doing so may`bend or damage the sheet metal. Suftable Mounting Surface Select non-combustible base type as desired or as required by local laws or codes. The generator is typically approved to be placed on pea:gravel,..crushed stone,or a concrete Installation Guidelines for 60 Hz Air-Cooled Generators 17 iIR "Road APPROVED AS NOTED COMPLY WITH ALL CODES OF DATE:2s t B•P# �'2 CO NEW YORK STATE&TOWN CODES F T aj�j BY: S REQUIRED AND CONDITIONS OF SOUTHOLD TOWN ZBA NOTIFY BUILDING DEPARTMENT AT SOUTHOLD TOWN PLANNING BOARD 631-765-1802 6AM TO 4PM FOR THE SOUTHOLD TOWN TRUSTEES FOLLOWING INSPECTIONS: N.Y.S.DEC FOUNDATION-TWO REQUIRED FOR POURED CONCRETE SOUTHOLD HPC ROUGH-FRAMING&PLUMBING SCHD INSULATION FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK 13LE FOR DESIGN OR•CONSTRUCTION NOT I ERRORS ELECTRICAL INSPECTION REQUIRED w GENERAC 10/14 1 W GUARDIAN° SERIES _ / Residential Standby Generators Air-Cooled Gas Engine INCLUDES: Standby Power Rating G007171-0,G007172-0(Aluminum-Bisque)-10 kW 60 Hz • True Power'm Electrical Technology G007223-10,G007224-10,G007225-10(Aluminum-Bisque)-14 kW 60 Hz • Two-line multilingual digital LCD EvolutionT" controller G007226-10,G007228-10(Aluminum-Bisque)-18 kW 60 Hz (English/Spanish/French/Portuguese) 4P, Two transfer switch options available: ,. 100 amp 16 circuit switch or ® Q 200 amp service rated smart switch • Electronic governor _ • Standard Wi-FiO connectivity. .; • System status&maintenance interval LED indicators • Sound attenuated enclosure - � � GENERAL • Flexible fuel line connector n - --�---�- �� • Natural gas or LP gas operation • 5 Year limited warranty • Lasted and labeled for installation as close as 18 in (457 Product shown with optional fascia kit y u mm)to a structure.* *Must be located away from doors, windows, and fresh or CEus �/ /�air intakes and in accordance with focal codes. V ` EFfE Note:CETL or CUL certification only applies to unbundled units and units packaged with limited circuit switches.Units packaged with the Smart Switch are ETL or UL certified in the USA only. FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This Generac's success in providing the most reliable generators possible.Geneirac's G= state-of-the-art power maximizing regulation system is standard on all Generac Force engine lineup offers added peace of mind and reliability for when you need it models: It provides optimized FAST RESPONSE to changing load conditions and the most.The G-Force series engines•are purpose built and designed to handle the, MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the rigors of extended run times in high temperatures and extreme operating conditions... . surge.loads to the engine.Digital voltage regulation at±1%. v inuc rvrvcn c*LruinionL(conitiuLuur.Superior harmonics and sine wave. . v 6111ULCauunur ach.vmc ncai-uirae from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit, from the engine to the allows confident operation of sensitive electronic equipment and micro-chip based smallest electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: "O 'GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with PROTOTYPE TESTED ✓ NEMA MG1=22 EVALUATION' GENERAC POWER SYSTEMS. One reason.for this confidence is the GENERAC SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK°WI-FI CONNECTIVITY: FREE with select Guardian Series home standby generators, Mobile Link Wi-Fi allows users,to monitor the status of the generator from anywhere in the world using a smartphone, tablet, or PC. Easily „ access information such as the current operating status'and maintenance alerts. Users can connect an'account to an authorized service dealer for fast,friendly,and proactive service. With Mobile Link, users are taken care of before the next power outage. A OMISE � ��` GEMERAd 10/14/18 kW. Features and-Benefits Generac G-Force design. Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. . • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. •. Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance. and longer engine•life.Now featuring up to a 2 year/200=hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • EPA Certified for non-emergency applications Allows unit to be used for demand response applications. • High temperature shutdown Prevents damage due to overheating, Generator •' Revolving field Allows for a smaller, light weight unit that operates M more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to:tl%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) . • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 313 Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near an existing distribution panel for.simple,low-cost installation. Evolution"Controls • AUTO/MANUAL/OFF illuminated buttons Select the operating mode and provide easy;at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage, • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power is delivered to the home. • Utility interrupt delay Prevents nuisance startups of the engine,adjustable 2-1500 seconds from the factory default setting of seconds by a qualified dealer. • Engine warm-up Verifies,engine is ready to assume the load.Setpoint approximately 5,seconds. 4 Engine.cool-down Allows engine to cool prior to shutdown,Setpoint approximately 1 minute.. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator fot'5 minutes every other week,'Offers a selectable setting for weekly or monthly operation,providing flexibility and potentially lowerfuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending'on outdoor air temperature, Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generatorfrom overload. • Electronic governor. Maintains constant 60 Hz frequency. Unit . • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front-for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm).away from a structure. C 10/14/18 kW Features and.Benefits Installations Svst--m • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to'the gas supply' piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity • Ability to view generator status Monitor your generator with a smartphone,tablet,or computer at any time via the Mobile Link application: for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generators complete protection profile for exercise hours and total hours, • Ability to view generator maintenance information Provides maintenance information foryour specific model generatorwhen scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery.. • Weather information Provides detailed local ambient weather conditions for generator location. GENERAC® 10/14/18 kW Specifications Model 10 kW 14 kW 1 B kW Rated maximum coatinuous power capacity(LP) 10 000 Watts 14 000 Watts 18 000 Watts .._: . Rated maximum continuous power capacity(NG) 9,000 Watts* 14,000 Watts* 17,000 Watts* Rated maximum continuous load current-240 volts(LP/NG) 41.7/37.5 58.3/58.3 75.0/70.8 Total Harmonic Distortion "``� � •� `Lessthari b% Main line circuit breaker 45 Amp 60 Amp 80Amp Phase �� ?.. t+ ......� ... •., ^;,.., . , . ..., .• `,. ,,..,. ... .. ,,. :` _.. .., .., ,.� � 1 ..,, .... ..,.., ,:xa„ .`.... __..,..,. . Number of rotor poles 2 Rated AC frequency! 60 Hz _ Power factor 1.0 Battery regwrement;(not mclutled} 12 Volts'�Group 26R 540;CCA Minimum or G[oup 35AUM 660 CCA Minimum ;` _ _.✓__ , Unitweight(lb/kg) 338/153 385/175 420/191 Dimaosions(LxWrxH)m/cm_; a,; „s;c,, ,, 48x25,x29,/1219x63,5.;x73,7 Sound output in dB(A)at 23 it(7 m)with generator operating at normal load** 61 65 65 SounddutpUt m d6(A}at 23 it(7m)with gereratot m Quiet Test low speed exercise mode;:", 57 55, 55 Exercise duration 5 min Engine Engine type GENERAC G-Force 400 Series GENERAC G-Force 800 Series Numtier o1 cylinders . Displacement 460 cc 816 cc Cylmtle[block Alurpmum w/'cast iron sleeve L Valve arrangement Overhead valve Lrftettype, Solid. ` Hydraulic Ignition system Solid-state w/magneto Governocsystem ! r,.. ..,. .•,..., ,Electronic,,. . „ . Compression ratio 9.5:1 Starter 12 VDC.,_. Oil capacity including filter Approx.1.1 qt/1.0 L Approx.2.2 qt/2.1 L O rPm 'PI., - . . perating Fuel consumption Natural Gas ft3/hr(m3/hr) 112 Load 101(2.86) 195(5.52) 169(4.79) Full Load 127(3.60) 256(7.25) 247(6.99) Liquid Propane 10/hr(gal/hr)[Uhr] 1/2 Load 36(0.97)[3.66] 65(1.81)[6.87] 62(1.70)[6.45] Full Load 54(1,48)[5.62] 112(3.07)[11.611 110(3.02)[11.441 Note{Fyel pipe must be sized for full load:Required fuel pressure;o generator fuel mist af'all load,ranges 3 5,7 Q'ia watercolumn(0 877-174 kPa)for NG i 0-12;m water co;fumn(2 49-2 99 kPa)for CP gas:Foy BTU.contentmultiplyft3/hr`x2;500(LP)orit3Lh'rx1,000':(NG).ForMegajbuledonteif multiplyin3/hiz93:15"(LP)or'm3Lfrx37;26;{NG) - Controls Two line;plaln text multilingual LGD r Simple user mtertaca for ease ol'operation Mode buttons:AUTO Automatic start on utility failure.Weekly,Bi-Weekly,or Monthly selectable exerciser. MANUAL r,, x a "' t Start vnth starter control;uhlt stays 66;l1 utility fails;transfer to'+load takes place OFF Stops unit.Power is removed.Control and charger still operate. Ready to;Run/AAairit'trance messages 4 ;< ,. •; - ,' Standard Engine run hours indication Standard Progiammable staff[delay between 2 1500 seconds Standard(programmable by dealer only) utility voltage loss/Return to utility adjustable(brownout setting) From 140-171 V/190-216 V Future set capable exerciser/Exercise set error warning Standard Run/Alarm/Maintenance logs 50 events each ` Engine'siart seq01, uence � ''r �"" � - ' `'"� '�"' Cyclic cranking:l6'sec on;7 sec rest(90"sec maximum duraton). Starter lock out Starter cannot re-engage until 5 sec after engine has stopped Smart Battery Charger t s r,.." -. r ,,_.,. � , . .., ., �.. ,,.��.�_t,_ . . ',� „ . ... ,r� ,..f.., .r�.,�� _. �+�,;f Standard .�,:._._ ' �t.,,, ., �,.._. ��.:..,• ,..��I Charger Fault/Missing AC Warning Standard L on StandadPrblemtectnBePo ryCondtion ndicatiowBaeryry Automatic Voltage Regulation with Over and Under Voltage Protection Standard UnderFrequency/Overload(Stepper Overcur[entProtection Standard _ Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown $tanda[d Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard 41­lighEn9i6e`T6rk ratureShutd"own Intemal Fault,Ancorrect Wiring Protection Standard Common:External Fault Capability .._ :.t•. Standard t, . . �, Field Upgradable Firmware Standard Rating definitions-Optional Standby:Applicable for supplying backup power for the duration of the utility power outage with correct maintenance performed.No overload capability is available for this rating.(All ratings in accordance with BS5514,IS03046,UL2200,and DIN6271). *Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/Megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 ft(304.8 m)above sea level and approximately 1%for each 10°F(6°C)above 60°F(16°C).**Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters. GENER Aril►" i 10/14/18 W. Switch Options Livaited Circuiis Switch FeaWres Model G007172-0 0007224i0 (10 kW) (14 kW) • 16 space,24 circuit.Breakers not included, No.of poles 2 • Electrically operated,mechanically-held contacts for fast,positive connections. Current rating(amps) 100 • resistive. Rated eed r all classes of load,100/°equipment rated,both inductive and I,Voltage------ (VAC) 120/240 10 • 2-pole,250 VAC contactors. Utility voltage monitor(fixed)* ° -Pick-up 80/° • 30 millisecond transfer'time. -Dropout 65% • Dual coil design. Return to utility " " Approx'15 sec '• Rated for both copper and aluminum conductors. Exercises bi-weekly for 5 minutes Standard • Main contacts are silver plated or silver alloy to resist welding and sticking. ;`ETC or UL Listed Standard • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor -. Gi c:_ mounting flexibility. Total circwts available 24 °Tandem breaker rapabihties 8 tandems • Multi listed for use with'1 in standard,tandem,GFCI,and AFCI breakers from _.. _ .c. ., . .L. .>..w_ __w.. .. .. ........ Siemens,Murray,Eaton,and Square D for the most flexible and cost effective Circuit breaker protected install. Available RMS Symmetrical 10,000 Faulf Current @ 250 Volts Dimensions *Function of Evolution controller Exercise can be set to weekly or monthly Height Width Depth Wl H1 H2 Wi W2 in 26.75 30.1 10.5 13.5 6.91 cm 67.94 76.43 26.67 34.18 17.54 H2 HI Wire Ranges Conductor Lug Neutral Lug Ground Lug 210-#14 2/0.-#14 2/0-#14 . • °Earl w2 Service Rated Smart Switch Features Model 0007225-10 0007228-10 • Includes Smart A/C Management(SACM)module standard. (14 kW) (18 kW) • Intelligently manages up to four air conditioner loads with no additional No of poles 2 __. Current rating(amps) 200 hardware. Vltae rating,( 120/240 iH • Up to eight large(240 VAC)loads can be managed with Smart Management o g g _ Modules(SMMs). Utilityvoltage monitor(fixed)" • Electrically operated,mechanically-held contacts forfast,'clean connections. -Pick-up 80% • Rated for all classes of load,100%equipment rated,both inductive and -Dropout 65% resistive. Returp to utility • 2-pole,250 VAC contactors. " 15 sec Exercises bi-weekly for 5 minutes* Standard ,�- • Service equipment rated,dual coil design. ETL 5779L Listed Standard d • ' Rated for both aluminum and copper conductors. Enclosure type NEMA/UL 311 • Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit breaker protecked 22 000 . • NEMA/UL 313 aluminum outdoor enclosure allows for indoor or outdoor Lug range 250 MCM-#6 mounting flexibility. *Function of Evolution Controller Dimensions Exercise can be set to weekly or monthly WI 200 Amps 120/240,is Open Transition Service Rated Height Width Depth H1 H2 Wi W2 in 26.75 30.1 10.5 13.5 .6.3 H2 HI cm 67.94 76.45 26.67 34.3 16.01 Wire Ranges Conductor Lug Neutral Lug Ground Lug DEPTH" W2 400 MCM-#4 350 MCM-#6 2/0-#14 GENERAL 10 141 8 kW Available Accessories ModelL# 5 ,� u�t� G005819-0' 26R Wet Cell Battery Every standby generator requires a battery to start the system Generac offers the recommended 26R wet cell bat `tery for use with all air-cooled standby product(excluding PowerPacte) G007101-0 'Battery Pad Warmer 'The pad warmer rests under the battery.Recommended for use if the temperature regularly falls below,0 ,F(-18: °C).'(Not necessary for use with AGM-style bat 401- 'GO07102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if the temperature regularly falls below 0°F(-18°C). °G007103-1 BreatherlNermer ithi breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in i (climates where heavy icing occurs. G005621 0 j Au)aliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load you may i Contact Kit not need.Not compatible with 50 amp,pre-wired switches: ,13007027-0-Bisque 'Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air cooled generators.This offers a sleek,con- toured appearance as well as offering protection from rodents,and insects by covering the lifting holes located in 'the base. r13005703-0-Bisque ;Touch-Up Paint Kit m' If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corrosion.The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator en-t € 'closure. ' ,. ,GO06482-0—1 0 kW :Scheduled Maintenance it Generac's scheduled maintenance kits provide all the items necessary to perform complete routine maintenance% G007216-0—14/18 kW on a Generac automatic standby generator(oil not included). ,The LTE enabled LP fuel level monitor provides constant monitoring-of the connected LP G007009 0 LTE LP Fuel Level Monitor p g fuel tanV'onitoring4he 4 LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power fail-x ure.Status alerts are available through a free application to notify users when the LP tank is in need of a refill. X07000-0(50 amps) ;Smart Management Module ;Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages; G007006-0(100 amps), ?large electrical loads upon startup and sheds them to aid in recovery when overloaded.In many cases, using, SMM's can reduce the overall size and cost of the system. '— 13007169-0(4G LTE) Mobile Links Cellular The Mobile Link family of Cellular Accessories allow users to monitor the status of the generator from anywhere r G007170-0(Wi-Fi/Ether- ;Accessories Jn the world,using a smartphone,tablet,or PC.Easily access information such as the current operating status and x met) Imaintenance alerts.Users can connect an account with an authorized service dealer for fast,friendly,and proac-; =tive service.With Mobile Link,users are taken care of before the next power outage. 6007220-0-Bisque Base Plug Kit ;Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,con- toured appearance,�as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & PCs .8 1218 J25.1 in] mm mm [48.O.In] 25 Model UPC G007171 696471074680 G007172 696471074673 G007223 696471082548 72.2 mm ]z s ml — G007224 696471082555 G007225 696471082562 G007226 696471082579 0 0 G007228 696471082586 648ai 1232mm. l2 in] [48.8 in, LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for;exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GENERAC® Generac Power Systems,Inc. S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com 02022 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice. Part No.A0000973374 Rev.0 09/19/2022 f ' ,