Loading...
HomeMy WebLinkAbout52478-Z of souryo�o Town of Southold * P.O. Box 1179 CA 53095 Main Rd COUNrs a`ice Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46885 Date: 03/06/2026 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 380 Knoll Cir East Marion, NY 11939 Sec/Block/Lot: 37.-5-11 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 10/29/2025 Pursuant to which Building Permit No..52478 and dated: 11/19/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof-mounted solar panels to an existing single-family dwelling as applied for. The certificate is issued to: Barbara Keller Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 114718 12/2/2025 PLUMBERS CERTIFICATION: Aut oriz ignature OfsoUryo`o TOWN OF SOUTHOLD BUILDING DEPARTMENT • �� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52478 Date: 11/19/2025 Permission is hereby granted to: Barbara Keller 11 Joyces Way Bay Shore, NY 11706 To: install roof-mounted solar panels to an existing single-family dwelling as applied for. Premises Located at: 380 Knoll Cir, East Marion, NY 11939 SCTM#37.-5-11 Pursuant to application dated 10/29/202S and approved by the Building Inspector. To expire on 11/19/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 CO-RESIDENTIAL $100.00 Total $200.00 --- — ----------- 7— ilding Inspector � ASSAIJ ELECTRICAL J. I MAR 6 2026 I-S:;,"'UFF0LK INSPECTORS I-A159 Route 25A, Building 1 Suite B Miller Place,NY 11764 Telephone:631 495 8136 - Fax:631 509 4538 • E-Mail:Requests@SuffolkBEI.com CERTIFICATE OF ELECTRICAL COMPLIANCE Applicant: Element Energy LLC Certificate No.: 114718 Rough In Inspection Date: Final Inspection Date: Dec 02,2025 Application No.: 9674303604 Building Permit No.: 52478 County Tax Map No.: 1000 037.00 05.00 011.000 LIPA Solar App No.: PAM-2025-394124 This Certificate of Electrical Compliance is limited to the inspection and compliance of electrical equipment and/or work described below,installed on behalf of the applicant named above,located at the premise of and not after the final inspection date above: Owner: ROBERT KELLER Site Location: 380 KNOLL CIRCLE,EAST MARION,NY 11939 Owner's Address(if different): ' 3 Residential 0 Indoor ❑Basement ❑Service ❑Shed ❑Commercial 0 Outdoor ❑First Floor ❑Pool ❑Hottub , 0 New 0 Renovation 0 Second Floor OAttic ❑Garage 9 ❑Addition ❑Survey 0 PV Solar ❑Generator ❑Conversion 0 Signs ❑Battery Storage 0 Safety Inspection Other: INVENTORY Single Phase 0 Heat Duplex Recpt 0 Ceiling Fixture 0 Dual Func Breaker ra Three Phase Hot Water GFCI Recpt Wall Fixture Smoke Main Panel AC Cond Single Recpt Recessed Fixture CO Detect Sub Panel AC Blower Range Recpt LED Lighting Smoke CO Combo ' Transformer Appliance Ckt Dryer Recpt Emergency Time Clock 0 - Disconnect Switches Twist Lock Exit Fixtures Pumps 0 GFCI Breaker Heat Pump Electric Heat 0 Pool Luminaire 0 Exhaust Fan 0 Other Equipment:System Size:12.47,kW Qty:29 Desc:EAGLE JINKO JKM430N-54HL4-B Qty:29 Desc:Enphase IQ8MC-72-M-US The electrical work and/or equipment described above were inspected and was found to be in compliance with local, state and national electrical code requirements and this office. Applicant: Element Energy LLC License No.: 52689-ME Date Printed: Dec 02,2025 Inspected By:Joe Coppola ' Signature: t ' t OF SOUTyo�o # TOWN OF SOUTHOLD .BUILDING DEPT. couto, 'Yo 631-765-1802 INSPECTION . [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND ' [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [vf'FINAL. 591,1t,/Z [ ] FIREPLACE &:CHIMNEY [ ] FIRE SAFETY INSPECTION [. ] FIRE RESISTANT CONSTRUCTION [. ] FIRE RESISTANT PENETRATION [ _ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: 40,4 f nS �&l l 00—�` G4 ct� AO OVA l^ 1 � u�rca �� � •e--. a G. d DATE /a o?3 aS — INSPECTOR SLING 1-i--) 1j Lh CONSULTING 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 MAR 6 2026 Heath J. Harpster, PE, P.Eng office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com i,hraid February 10, 2026 Element Energy LLC 7470 Sound Avenue, Mattituck, NY, 11952 Re: Engineering Services (Post-Install) Keller Residence 380 Knoll Circle, East Marion, NY 12.470 kW System To Whom It May Concern: Pursuant to your request, we have reviewed the installation of the above-referenced solar panel system. As you are aware, this office initially prepared a structural assessment, dated October 29,2025, of the solar panel installation. This installation was inspected and found to be in compliance with the layout plan as specified in our report, product installation criteria, and the requirements of the current building code. We have determined that the equipment will not create a negative impact on the building's structural design, including any additional loads imposed (dead, snow, wind). This letter pertains only to the panel support attachments to the roof framing and not the engineered photovoltaic panel products, components, or electrical-related installations/connections. Should you have any questions regarding the above or if you require additional information do not hesitate to contact me. NE yours, L-L!1� truly Scott E. Wy sli PE 3 New York License N 03 C; U New York COA No. 0 571 36 k1sa violation of the law for anyperson.unless acting under.the dire6tion ii)f.a licensed professional,to alter an item in any Way.If an WysrWho Coftulfifig, PLLC .76:N. Meadbwbtoolk:Drive,Alpine. UT item 6earingthe seakola licensed professional New Vrork WA#0022571 'is altered;the altering licensed professional,shall affix to Kem thbi,r, nd:the notation Signed 2/10/2026 ".2,31taredby"foltowed.hyth.eir signature and the Expires 7/31/2027 'date of such'alterarion,and a specific description of the alteration. FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (IST) — -- -- -- a ------------------------------------- C FOUNDATION (2ND) - d cn ROUGH FRAMING & — - PLUMBING 1 � 1 1 � r r� INSULATION PER N.Y. - -- "� STATE ENERGY CODE — _—�k C.a. - — FINAL ADDITIONAL COMMENTS _ -7- c y0 � fie.c. c U 3 F — b N o -- r b o`�S�FFa�KcG TOWN OF SOUTHO1LD—.BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. 0. Box 1179 Southold, NY 11971-0959 'y • o* Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT Far Office Use Only I OD 0� PERMIT NO. �_5 rq I - Building Inspector: OCT 3 0 2025 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an $landing Department Owner's Authorization form(Page 2)shall be completed. Town of_qoUt}�cll i. , Date: O -1 OWNER(S)OF IIP--ROPE 1RTY: L _ Name: b C)C. 't �e,��e lr' SCTM # 1000- 03 . ob _ O 5,Od -..O )1 . oaa Project Address:3S 0 Knoll Ct rd C .A S{ m io"or) t� ( �3 Phone#: -5 1 (p -630i — 1S w )� Email: � k� I t nitc.'KerSoy1C0 Mailing Address Q 0 K ' � n 0 ) Ci 1rG� G�}' YYl 8•-Yl�c1� _`�, l�a 3 CONTACT PERSON: Name: rr b ) ��yl Mailing Address: a4l Phone#: 7 Email: ��� �aI- @��ot� C.O hl DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Mailing Address: 1 4' Phone#: 1 v 0 Ltl Email: errn1� DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demol•yytion Esti ated Cost st of Project: Other -b-a l I1�,S O I OLa 'P X1 6 D I 7 Kw Will the lot be re-graded? ❑Yes NO Will excess fill be removed from premises? Dyes o 1 ;.PROPERTY INFORMATION, Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ❑No IF YES, PROVIDE A COPY. ❑ Check Box After Reading .The owner/contractor/design professional is responsible for alCdrainage,and storm water issues as provided by Chapter 236 of the Town Code: APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinake of the Town of Southold;Suffolk;County New.Yoik and`other applicable Laws,,Ordinandes or Regulations„for the'construction of'buildings, additions;alterations or for removal or demolition as herein described:The applicant agrees to comply with all applicable laws;ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in 6uiiding(s)for necessary inspections.False statements made herein are punishable"asa.Class A misdemeanor pursuant to Section.210:45 of the New York State Penal Law. Application Submitted By(print name): W ry—al nQ.l DI P-Z`L ,� Authorized Agent El Owner Signature of A licant: Date: STATE OF NEW YORK) � rS: COUNTY OFU3U 1 being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the C4_1��� (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this ry day of 20 OCR Nota P IIc DEBRA A SEPULVEDA PROPERTY OWNER AUTHORI ATKS}Q' yPUBugsrAimoF?awyoRc (Where the applicant is not the caner) Re&tradonNo60JSE60126ff QuMed in Sliq COun II �Q K MYICom(m'tssiony�Expires 1.0 residing at 3U O ' `n GI �--+ t_r_tC.J W� 1I 1� ►(,V)�On vl . do hereby authorize to apply on my behalf to/the Town of Southold Building Department for approval as described herein. toh0 `&. Owner's Signature Date �bjy_f� Ke� I lt — Print Owner's Name 2 APPRO VED AS NOTED DATE• LI B.P.#E FEE BY NOTIFY BUILDING DEPARTMENTAT 631-765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW ELECTRICAL YORK STATE. NOT RESPONSIBLE FOR INSPECTION REQUIRED DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE &TOWN CODES AS REQUIRE/AND NDITIONS OF WN ZBA WN PLANNING BOARD WN TRUSTEES C OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY &OWSSLING NSu� NG in 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Heath J. Harpster, PE, P.Eng office(201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com October 29,2025 Element Energy LLC 7470 Sound Avenue, Mattituck, NY, 11952 Re: Engineering Services Keller Residence 380 Knoll Circle, East Marion, NY 12.470 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: 2 x 10 dimensional lumber spaced at 16" on center. Roof Material: Composite Asphalt Shingles Roof Slope: 20, 37, &38 degrees Attic Access: Accessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing= 7 psf o New Solar Panels and Racking= 3 psf o TOTAL= 10 PSF • Live Load =20 psf(reducible)—0 psf at locations of solar panels • Ground Snow Load =25 psf o Wind Load based on ASCE 7-16 o Ultimate Wind Speed= 134 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2020 NYS Residential Code (2018 IRC). This analysis indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent IronRidge installation manual. If during solar panel installation,the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a#14 lag screw is 194 Ibs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on two screws with a minimum penetration depth of 2",the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances,the connection using two# 14 lag screws with a minimum of 2" embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of rafters,-and condition of the roof, the panel supports shall be placed no greater than 48" on center. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2020 NYS Residential Code (2018 IRC), current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. V t`y yours, Scott E.Wyssli /, PE NY PE License No. 4 NY COA#0022571 � f N�cl.` + c:3 r R, 1 ylMing Consulting, PLILC M.N. Mea4ow brook Drive,Alpine UT New York GOA#0022571 Signed 10/29/2025 Expires 7/31/2027 is a violation of the law forany'person,un[ess acting undertheAirection of.a licensed ;professional,to alter an item in any way.If an item bearingthe-sealota licensed professional 'is altered,the altering.licensed professional shall affixto their item theiusealand:the,'motation "attered by"foilowed bytheir sigriafure and the date of"sudh alferatibn,and a specific description of the alteratiorb, JUYSSIMG s� CONSULTING CONTRACTOR ROBERT KELLER ELEMENT d Ej ® ENERGY AHJ UTILITY SCOPE OF WORK VICINITY MAP SOLARI BATTERY BACKUP 1631.779.79931E2sY5.COM TOWN OF SOUTHOLD LONG ISLAND POWER AUTHORITY (N) 12.470KW DC/9.280KW AC ROOF MOUNTED PV SYSTEM ELEMENT ENERGY LLC (29)JINKO SOLAR JKM430N-54HL4-B MODULES 7470 SOUND AVE, (29) ENPHASE IQ8MC-72-M-US (240V) MICROINVERTERS MATTITUCK, NY 11952, USA CODES AND STANDARDS WITH AMENDMENTS (01) ENPHASE IQ COMBINER 515C PANEL a^ ~` ` +1 631 760 7262 2020 BCNYS LIC TYPE: HOME 2020 FCNYS IMPROVEMENT, MASTER 2020 RCNYS ELECTRICIAN 2017 NEC �'' LIC NO.: 67461-HI, 52689-ME 1 380'Knoll-Gir,East i { M_arion,NY 11939; i PROJECT INFO&ADDRESS 1 United States ROBERT KELLER ENVIRONMENTAL WIND SPEED: 134 MPH 380 KNOLL CIR, SNOW LOAD: 25 PSF 4 SprbV Pond EAST MARION, EXPOSURE CATEGORY: C ----��_--- --_-__-- . _ NY 11939, USA SYSTEM SIZE DC SIZE: 12.470 KW DC-(STC) AC SIZE: 9.280 KW AC GENERAL NOTES PROJECT NOTES: METER NO: 98398219 SHEET INDEX OF N -THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE ACCT NO: 98398219 PV-1 COVER SHEET NATIONAL ELECTRIC CODE (NEC)ARTICLE 690,ALL PV-2 SITE PLAN-1 MANUFACTURER'S LISTING AND INSTALLATION INSTRUCTIONS, PV-2.1 SITE PLAN-2 i 4, f ' AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY PV-3 ATTACHMENT PLAN ,- HAVING JURISDICTION'S AHJ APPLICABLE CODES. PV-3.1 STRUCTURAL PLAN { "' -THE UTILITY INTERCONNECTION APPLICATION MUST BE PV-4 ELECTRICAL APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL PV-4.1 ELECTRICAL CALCULATIONS OPERATION PV-5 LABELS -GROUND FAULT DETECTION AND INTERRUPTION (GFDI) PV-6 RESOURCE DOCUMENT ' ' r S!�➢ '`' DEVICE IS INTEGRATED WITH THE MICRO INVERTERS IN PV-6.1 RESOURCE DOCUMENT Wps1ftWg C s lltIng, PLILC ACCORDANCE WITH NEC 690.41(B) PV-6.2 RESOURCE DOCUMENT 76 N. eadoWbirook Onve,.Alpiine UT -ALL PV SYSTEM COMPONENTS; MODULES, PV-6.3 RESOURCE DOCUMENT owYprk CG'A�fl022571 UTILITY-INTERACTIVE INVERTERS,AND SOURCE CIRCUIT PV-6.4 RESOURCE DOCUMENT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN PV-6.5 RESOURCE DOCUMENT Signed 10/29/2025 PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4: PV PV-6.6 RESOURCE DOCUMENT Expires 7/31/2027 MODULES: UL1703, IEC61730,AND IEC61215,AND NFPA 70 PV-6.7 RESOURCE DOCUMENT It is avioletion.ofthe I'w for any person,unless CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, PV-6.8 RESOURCE DOCUMENT acting uhd&the dire tionof:alicehsed 519 COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY OrofessionaLto:atter. nitominanyw.ay;liari -MAX DC VOLTAGE CALCULATED USING MANUFACTURER itembearingthe-seal 3f.a.lieensedprofessional PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX is aitered-rtheal..terinf.licensedprofessionalshall DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7: affixto-their item theii,seat andthenotation -ALL INVERTERS, PHOTOVOLTAIC MODULES,PHOTOVOLTAIC "altered byA-followed y their signature and the PANELS,AND SOURCE CIRCUIT COMBINERS INTENDED FOR date:of'such:alteratioi-and-a-specifie USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED de. scriptionofthe:att ratr&t kWN BY AK AND LISTED FOR THE APPLICATION PER 690.4. SHALL BE DATE 10/25/2025 INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING [NEC 110.3]. REVISION -ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL SIGNATURE BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT.ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS PV-1 REQUIRED BY THE NEC AND AHJ. COVER SHEET CONTRACTOR SCOPE OF WORK TOTAL ROOF SQUARE FOOTAGE IS:3046.66 FTZ (N) 12.470KW DC/9.280KW AC ROOF MOUNTED PV SYSTEM NEWARRAY SQUARE FOOTAGE IS: 609.56 FTZ ELEMENT (29)JINKO SOLAR JKM430N-54HL4-1B MODULES COVERED BY SOLAR IS: 20.01% 11 ® ® ENERGY (29) ENPHASE IQ8MC-72-M-US (240V) MICROINVERTERS IV SOLARI BATTERY BACKUP 1631.779.79931E2SYS.COM (01) ENPHASE IQ COMBINER 515C PANEL -'� ELEMENT ENERGY LLC 7470 SOUND AVE, X')' /rho MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER /1 ELECTRICIAN LIC NO.: 67461-HI, 52689-ME PROJECT INFO&ADDRESS P—� S� ROBERT KELLER 11 380 KNOLL CIR, EAST MARION, NY 11939, USA SYSTEM SIZE DC SIZE: 12.470 KW DC-(STC) (E)MAIN HOUSE AC SIZE: 9.280 KW AC C-` G � � VVyss0injo Cof sulltiinq, PLLC �/ 7S N.Meado` brook Drive,-;Alpine JT New York COA#0022571 �0 3:10rr / Signed 10/29/2025 Expires 7/31/2027 Itisaviolationofthe awforanyperson,.unless actingunderthe dire tion ofa licensed professional,to alter n item in any way.if an item bearing of.a:ticensedprofeasional LEGEND is altered,_the altering licensed professional shall ®FIRE PATHWAYS affix toilaeir item,thei rseal and the notation "altered by"followedi by'th lr signatute and the' PROPERTY LINE dateof such alterati ,and.aspecific 0 FENCE description of the alt rabRRAWN BY AK ® SKYLIGHT/CHIMNEY DATE 10/25/2025 O ❑ VENT/OBSTRUCTION REVISION SIGNATURE SITE PLANA PV-2 SCALE:1/32" = V-0" NOTE-N FENCE OR GATE PRESENT IN SITE PLANA CONTRACTOR SCOPE OF WORK (N) 12.470KW DC/9.280KW AC ROOF MOUNTED PV SYSTEM TOTAL ROOF SQUARE FOOTAGE IS:309.566 FTz ELEMENT (29)JINKO SOLAR JKM430N-54HL4-B MODULES NEW ARRAY SQUARE FOOTAGE IS: 60 .56 FTz COVERED BY SOLAR IS: 20.01% d 0 IN ENERGY (29) ENPHASE IQ8MC-72-M-US (240V) MICROINVERTERS SOLAR I BATTERY BACKUP 1631.779.79931 EZSYS.COM (01) ENPHASE IQ COMBINER 515C PANEL ELEMENT ENERGY LLC 7470 SOUND AVE, LADDER ACCESS Q MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER o ELECTRICIAN Cry. LIC NO.: 67461-HI, 52689-ME (N 29)-JINKO SOLAR JKM430N-54HL4-B MODULES WITH PROJECT INFO&ADDRESS (N)ENPHASE IQ 5/5C COMBINER PANEL ENPHASE IQ8MC-72-M-US(240V)MICROINVERTERS ROBERT KELLER WITH ENPHASE IQ GATEWAY °� UNDER EACH MODULE(240V) (OUTSIDE GARAGE) a 380 KNOLL CIR, (N)VISIBLE LOCKABLE LABELED 3�O" EAST MARION, AND FUSED AC DISCONNECT �� NY 11939, USA (UTILITY DISCONNECT) `0 j (OUTSIDE GARAGE) SYSTEM SIZE (E)ATS PANEL 1 03 DC SIZE: 12.470 KW DC-(STC) (OUTSIDE GARAGE) ` AC SIZE: 9.280 KW AC (E)UTILITY METER (OVERHEAD SERVICE) (OUTSIDE GARAGE) 3 00 r (E)MAIN SERVICE PANEL } -1 (INSIDE BASEMENT) co O (N)CONDUIT RUN 3► �, ems. �O r Wyssiing Ceitisaulting, PLLC CID O 7 8 N.Meadawbroo:k Drive,.Alpine 6T r Nea++i'York COI#0022571 e� o O Signed 10/29/2025 Expires 7/31/2027 ® M It is a ViolatiOn of the I aw for ahy person,unless actingunderthe dire Lion of.a licensed LEGEND professional,-to alter n item in any Way.l f=an t, item bearing the seal f a,licensed professional ®FIRE PATHWAYS V is altered,the alterin .licensed professional shall affix to their item ttlei,seal and the.notation PROPERTY LINE "altered by"followed :)ytheir signature and the Q FENCE date:of such alteratioi iTq—rqd aaa socifi ® SKYLIGHT/CHIMNEY descriptionoftheaLt V�lN BY AK O ❑ VENT/OBSTRUCTION DATE 10/25/2025 REVISION SIGNATURE SITE PLAN-2 PV-2.1 SCALE:3/32" = 1'-0" CID3�0" SITE PLAN-2 ROOF SECTION(S) CONTRACTOR ROOF MATERIAL- � M ELEMENT ASPHALT SHINGLE ENERGY S13LARI BATTERY BACKUP1631.779.79931 E2SYS.COM ROOF 1 RAFTER SIZE-2"X10" 1'-8" O.C. SPACING- 16"' 3'-4" 22'-10" 13'-9" 1 V-4" I I I I I1 I1 I I I I I I I I iI - cV ELEMENT ENE R G Y LLC MODULES- 11 — II I I I 7470 SOUND AVE, ROOF MATERIAL- M MATTITUCK, NY 11952, U S A ASPHALT SHINGLE +1 631 760 7262ROOF2 RAFTER SIZE-2"X10" 1 I I LIC TYPE: HOME O.C. SPACING- 16 IMPROVEMENT, MASTER MODULES-6 in ELECTRICIAN ROOF MATERIAL- i i 1 i I i 1 LIC NO.: 67461-HI, 52689-ME ASPHALT SHINGLE I I I I I I I I I I I I I I I I I I I I I I I ROOF 3 RAFTER SIZE-2"X10" "' I I I I I I I I I I O.C. SPACING- 16 I I I I I I I I I I I I I I I I I I I 1 I PROJECT INFO&ADDRESS 1 1 1 1 1 1 1 1 1 1 I I I I I I I I I I I I I ROBERT KELLER MODULES- 12 I I I I 1 1 1 I I I I I I I I I I 380 KNOLL CIR, 74'- f EAST MARION, ARRAY 1 ARRAY 2 NY 11939, USA TILT- 38 DEG TILT- 20 DEG SYSTEM SIZE AZIMUTH - 197 DEG DC SIZE: 12.470 KW DC-(STC) DEAD LOAD CALCULATION AZIMUTH - 246 DEG AC SIZE: 9.280 KW AC TOTAL BOM QUANTITY LBS/UNIT WEIGHT(LBS) f , -- t- JINKO SOLAR 29 48.5 1406.50 8�1 6" rcAll JKM430N-54HL4-B MODULES 31 -5 4 a lr 1 MID-CLAMP 30 0.15 4.50 e'� ?. END-CLAMP 56 0.15 8.40 RAIL LENGTH 34 6.36 216.24 I I i 1 i 1 i SPLICE BAR 06 0.525 3.15 1 1 i I I 1 I I IRONRIDGE HALO ULTRA 103 0.57 58.71 I 10�`�y GRIP I I I I I I I I I I I ENPHASE IQ8MC-72-M-US 29 2.43 70.47 I I I I I Wy/ss i ng ConA uf3ing, PLLO (240V) MICROINVERTER O I I I I I I I I 71 N, Meaddwbroc,k Di9Ye.,Alpine I T TOTAL WEIGHT OF THE SYSTEM (LBS) 1767.97 I I 1 I 1 1 1 1 I I 1 i I I 1 1 I 1 1 C' I I I I I I I I I I I I I I I I I i 1 1 1i 1 I I I I II ap New York COA#t022571 TOTAL ARRAY AREA ON THE ROOF (SQ.FT) 609.56 Signed 10/29/2025 I I I I I I I I I I I 1 1 I I I I WEIGHT PER SQ.FT. (LBS) 2.31 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Expires 7/31/2027 I I I I I I I I I I I 1 I I I I I I I I I WEIGHT PER PENETRATION (LBS) I 1 I 1 1 1 It i s a vi olation of tth e law for any person,unless I I acting under the ditection of a licensed I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 I I I I I I I I I I I I I I I I I professional,to;altIleran item in anyway.if an I I I I I I I I I I I I I I I I 1 1 1 1 1 1 I I I I I I I I I I I I 1 I 1 I I 1 I 1 I item bearing the s4slpf a Licensed professional - CLAMP I I I i I 'is altered,the altering licensed professional shall I I I I I I I I I I I I i 1 1 I 1 I 1 I affixththeir9tern11I eir.sealand the notation • I I I I I I I I I I I I 1 1 1 I I I I "a.lteedby"fouow�d'iytheir sig naturb and the HALO ULTRA GRIP date of such,alteraion,andas ecific descri t_onofthe iteration. IRONRIDGE AIRE Al I I I I I I I I I I I I i DRAWN BY AK I I I I I I I I I I I --------- - RAFTER 1 I 1 1 I 1 I I I 1 i l i DATE 10/25/2025 I I I I I I I I I I I 103 -TOTAL MOUNT I I I I i 1 1 1 1 1 1 i REVISION SIGNATURE ARRAY 3 1 ATTACHMENT PLAN TILT- 37 DEG PV-3 SCALE:1/8"=1'-0" AZIMUTH - 197 DEG ATTACHMENT PLAN CONTRACTOR --" MELEMENT ENERGY SOLARIBATTERY BACKUP1631.779.79931EZSYS.CDM ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN LIC NO.: 67461-1-1I, 52689-ME MODULE BOTTOM MOUNTING CLIP PROJECT INFO&ADDRESS CLAMP w 4" BOLT ROBERT KELLER AND LOCK WASHER 380 KNOLL CIR,EAST MARION, JINKO SOLAR JKM430N-54HL4-B NY 11939, USA SYSTEM SIZE MODULE / i DC SIZE: 12.470 KW DC-(STC) AC SIZE: 9.280 KW AC IRONRIDGE AIRE Al / / 8 BOLT o c ZA (E) ASPHALT SHINGLE zF "? �Z4 �3 IRONRIDGE QUICKMOUNT HUG (2) 1/4" x 3" STAINLESS STEEL SCREWS, SELF DRILLINGxi� ' ' s�jQ ', SCREW WITH MINIMUM 2" ySsli g Consullipg. PLC ' .76 N.Me2doWbiroo(k Drive-,Alolne U! EMBEDMENT wewYorkCOA#0022571 Signed 10/29/2025 Expires 7/31/2027 It is a violation of the lawfor any person,unless acting underrthe dif ection of a lieensed professioriat,to oft ran item in anyway ff an item bearing the set of a licensed professional n n nr is altered,the after g licensed professional shall (E) RAFTER 2 X 10 @ 16 O.C affix=to their itern t it seal o nd fhe-nptetiai, "atteriedby--follow(idW'theirsi naituto ridthe' date of such attera ion) lA%0q31(ic AK description fllthe 2 Ire-ration. DATE 10/25/2025 REVISION SIGNATURE 1 STRUCTURAL PLAN PV-3.1 SCALE:NTS STRUCTURAL PLAN CONTRACTOR SOLAR MODULE SPECIFICATIONS INVERTER SPECIFICATIONS ELEMENT MANUFACTURER/MODEL# JINKO SOLAR JKM430N-54HL4-B MANUFACTURER/MODEL# ENPHASE IQ8MC-72-M-US(240V) MICROINVERTER NOTE: ENERGY VMP 32.58V MIN/MAX DC VOLT RATING 22V MIN/58V MAX - ALL CONDUCTORS ARE COPPER UNLESS OTHERWISE 50LARI BATTERY BACKUP 1631.779.79931 E25YS.COM IMP 13.20A MAX INPUT POWER 460W NOTED. VOC 39.16V NOMINAL AC VOLTAGE RATING 240V/211-264V ELEMENT ENERGY LLC ISC 13.65A MAX AC CURRENT 1.33A 7470 SOUND AVE, TEMP.COEFF.VOC -0.25%/°C MATTITUCK, NY 11952, USA MAX MODULES PER STRING 12(SINGLE PHASE) +1 631 760 7262 MODULE DIMENSION 67.79"L x 44.65"W x 1.38"D(In Inch) MAX OUTPUT POWER 320 VA LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN LIC NO.: 67461-1-1I, 52689-ME METER NO: 98398219 ACCT NO: 98398219 PROJECT INFO&ADDRESS (N)(1)ENPHASE IQ COMBINER 5/5C TO UTILITY GRID ROBERT KELLER (N)(29)JINKO SOLAR JKM430N-54HL4-B WITH ENPHASE IQ GATEWAY, L1 L2 N MODULES (3)20A/240VAC CIRCUIT (E)BI-DIRECTIONAL UTILITY 380 KNOLL 12 MICROINVERTERS IN BRANCH CIRCUIT 1 EAST MARION �. (3)#12 Q-12-RAW-300, BREAKERS 125A RATED (N)(1)AC DISCONNECT: LINE METER 1-PHASE,3-W, , THHN CABLES (OUTSIDE GARAGE) VISIBLE,LOCKABLE AND LABELED M 120V/240V,200A RATED 60A FUSED,(2)50A FUSES,240V (OVERHEAD SERVICE) NY 11939, USA PER MANUFACTURER IQ GATEWAY NEMA 3R,UL LISTED LOAD (OUTSIDE GARAGE) SYSTEM SIZE SPECIFICATIONS,EITHER (UTILITY DISCONNECT) F -�, r- 10A OR 15A OR 20A (E)MAIN SERVICE PANEL, DC SIZE: 12.470 KW DC-(STC) 71 vwR ss (OUTSIDE GARAGE) 200A RATED,240V SUITABBE FOR USE REAKERIScoMms �z 1-z SUPPLY SIDE TAP (INSIDE BASEMENT) AC SIZE: 9.280 KW AC z I ' 15Al2 N N (E)ATS BREAKER (E)MAIN BREAKER 11 MICROINVERTERS IN BRANCH CIRCUIT 2 I— JUNE N — 240V,200A/2P TO HOUSE EA ER 20A/2P I 2 I I 3 200A/2P P':,i �;y� � • 1 I z0v2P I II I ------J n ` —— —— — L, z I I G N (E)ATS PANEL,G200A RATED,240V6 MICROINVERTERS IN BRANCH CIRCUIT 3 20azP II L— 47 — (OUTSIDE GARAGE) I r; j cec LINE SIDE I N `t ! 1 jL� ec. EXISTING GROUNDING N INTERCONNECTION I c %' ,� d I• I ELECTRODE SYSTEM TO I L- --0G EARTH —j— AT ATS PANEL �' I REF.NEC 250.52,250.53(A) i PER ART.705.12(A) Wyssfing Cobs uf, ng, PILILC 76 N.Mead owbroolk Drive.,Alpine U Now York COA#0022571 (N)(29)ENPHASE IQBMC-72-M-US (240V)MICROINVERTERS ONE UNDER L(E) GENERATOR Signed 10/29/2025 EACH MODULE(240V) Expires 7/31/2027 It Ise violation of the lawfor any person,unless acting under the dit ection of.a licensed ,professianst,to alt r.an item in anyway.If an item bearing t eseiilofalicensedprofessional PHASE CONDUCTOR QTY, SIZE AND TYPE GROUND CONDUCTOR QTY, SIZE CONDUIT CONiElk Ted,,the iter glicensedprofessionalshall ID PER CONDUIT NEUTRAL QTY, SIZE AND TYPE PER CONDUIT AND TYPE PER CONDUIT SIZE TY too tfse3r it m t it seal andthe notation "altered by"Jo loin d W'their signature and the \d/ate of such a<era iOID. tMgG1f1c AK 1 3 AWG #12 Q CABLES,THHN NA NA NA 1 AWG #8 BARE,COPPER EGC 3/4" PWIriptiono'f heIteration.. DATE 10/25/2025 2 2 AWG #6 THWN-2,COPPER 1 AWG #6 THWN-2,COPPER 1 AWG #8 THWN-2,COPPER EGC 3/4" PVC REVISION SIGNATURE 3 2 AWG #6 THWN-2,COPPER 1 AWG #6 THWN-2,COPPER 1 AWG #6 THWN-2,COPPER EGC 3/411 PVC PV-4 E EXISTING CONDUCTORS AND CONDUIT ELECTRICAL CONTRACTOR ® ® ELEMENT ENERGY AMBIENT TEMPERATURE SPECS NUMBER OF CURRENT BULARIBATTERY BACKUP 1631.779.79931EZSYS.COM PERCENT OF VALUES CARRYING CONDUCTORS IN EMT RECORD LOW TEMP -14° ELEMENT ENERGY LLC 7470 SOUND AVE, AMBIENT TEMP (HIGH TEMP 2%) 270 0.80 4-g MATTITUCK, NY 11952, USA CONDUIT HEIGHT 7/8" 0.70 7-9 +1 631 760 7262 ROOF TOP TEMP 490 0.50 10-20 IMPROVEMELIC TYPE: NT, MASTER CONDUCTOR TEMPERATURE RATE 900 ELECTRICIAN LIC NO.: 67461-HI, 52689-ME MODULE TEMPERATURE COEFFICIENT OF Voc -0.25%/°C PROJECT INFO&ADDRESS ROBERT KELLER CALCULATIONS: 380 KNOLL CIR, EAST MARION, 1. CURRENT CARRYING CONDUCTOR 2. PV OVER CURRENT PROTECTION NY 11939, USA SYSTEM SIZE ...NEC 690.9(B) DC SIZE: 12.470 KW DC-(STC) (A) BEFORE IQ COMBINER PANEL = TOTAL INVERTER O/P CURRENT x 1.25 AC SIZE: 9.280 KW AC AMBIENT TEMPERATURE - (27)OC ...NEC 310.15(B)(2)(a) _ (29 x 1.33) x 1.25 = 48.21 A a,.. TEMPERATURE DERATE FACTOR - 1 ...NEC 310.15(B)(2)(a) c31 �E, +"it GROUPING FACTOR - 0.8...NEC 310.15(B)(3)(a) � CONDUCTOR AMPACITY LL _ (INV O/P CURRENT ) x 1.25 / A.T.F / G.F ...NEC 690.8(B) _ [(12 x 1.33) x 1.25] / [1 x 0.81 = 24.94A SELECTED CONDUCTOR - #12 THHN ...NEC 310.15(B)(16) Ala► sling Cbnsulli ng,PLLC ?6 N.Il endow rook Driere,,A,l�nine UT New York Cf7A#0022571 Signed 10/29/2025 Expires 7/31/2027 (B) AFTER IQ COMBINER PANEL It Is avialatiorrvfttIvWw for any person,.uNow actingunder:theditection of:a licensed TEMPERATURE DERATE FACTOR — 1 professional,fo.altllE ran item in-any way.ffan GROUPING FACTOR — 1 itemliearingtheseial,of:a,Licensedprofessional is altered,,the altering licensed professional shad affixto their item t ei r.seal and the notation CONDUCTOR AMPACITY "alt red'by foLlo d-' 'th6irsi n6tufeandthe' date of-such alter ioLir ig, {fic AK _ (TOTAL INV O/P CURRENT) x 1.25 / 1/ 1 ...NEC 690.8(B) descriptionofthe . DAIS 10/25/2025 = [(29 x 1.33) x 1.251 / [I x 11 REVISION = 48.21 A SIGNATURE SELECTED CONDUCTOR - #6 THWN-2 ...NEC 310.15(B)(16) PV-4.1 ELECTRICAL CALCULATIONS CONTRACTOR Solar Module Solar Module Main Service ELEMENT Microinverter ATS Panel COMBINER PANEL PanelN ENERGY 17-7 SOLAR I BATTERY BACKUP 1631.779.7993I E2SYS.COM Outside Door Outside Door AC Disconnect 3,9,10 y ' Outside Door 6 6 6 ELEMENT ENERGY LLC 3.4 Inside Door Inside Door 7470 SOUND AVE, 3,6,8,9,11 5,6,7 5,67 MATTITUCK, NY 11952, USA 41 Inside Door +1 631 760 7262 OEM Cables should be marked by the manufacturer 5.6.7 *CUStOm *Custom LIC TYPE: HOME Directory Directory IMPROVEMENT, MASTER Placard Placard ELECTRICIAN NEC 690.13(B) LIC NO.: 67461-HI, 52689-ME NEC 690.54 NEC 690.56(C) NEC 690.13(B) NEC 690.13(B) PROJECT INFO&ADDRESS NEC 690.13(B) NEC 705.12(A) NEC 705.12(B)(3) NEC 690.56(B) NEC 690.56(B) ROBERT KELLER NEC 690.56(B) NEC 705.12(B)(3) NEC 705.10 NEC 705.10 NEC 705.10 NEC 705.12(A) NEC 705.12(A) 380 KNOLL CIR, NEC 705.12(B)(3) NEC 705.12(B)(3) EAST MARION, NY 11939, USA IN-101' 78CAUTION: SOLAR ELECTRIC SYSTEM SIZE SYSTEM CONNECTED DC SIZE: 12.470 KW DC-(STC) ELECTRIC SHOCK HAZARD AC SIZE: 9.280 KW AC IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED SOLAR PV SYSTEM EQUIPPED CAUTION WITH RAPID SHUTDOWN (1F t, TURN RAPID SHUTDOWN POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE Q� ' ❑2 I Fq� SWITCH TO a�EE« FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: "OFF"POSITION TO SHUT DOWN PV SYSTEM s �,anee�s is ELECTRIC SHOCK HAZARD AND REDUCE 4 SHOCK HAZARD THE DC CONDUCTORS OF THIS IN THE ARRAY N PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED Q� t , ~ 3 F1-0 CAUTION: SOLAR CIRCUITCr� I�ca4�ti 1 —1116 ELECTRIC SHOCK HAZARD COMBINER PANEL Wyssling Consulting. PLLC DO NOT TOUCH TERMINALS (OUTSIDE GARAGE) 76IN. Meadowbroolt Drive, Alpine V TERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM AC DISCONNECTUTILITY DISCONNECT New York COA 40022571 LOAD SIDES MAY BE ENERGIZED • • AC OUTPUT CURRENT (OUTSIDE GARAGE) IN THE OPEN POSITION 11 • • ATS PANEL Signed 10/29/2025 (OUTSIDE GARAGE) Expires 7/31/2027 UTILITY METER (OVERHEAD SERVICE) it Is a Violation of t e taw for any person,unless • r. • (OUTSIDE GARAGE)4] MAIN SERVICE PANEL acting under the di ection of a licensed No user serviceable•. . inside (INSIDE BASEMENT) professional,to attar an item in any way.If an item bearing the seatof a licensed professional ' is altered,the alteing licensed professional shall 5 VINI :DUAL Pd R SOURC affix to their item their seal and the notation PV ARRAY SECOND SOURCE IS PHOTOVOLTAIC SYSTEM "altered by"foilr 99�e�frt�,sfgtfR�2atu dtfledate of such altetd'$s e�fic AK F6] WARNING: • • • description of the ItSyki`V T, 10/25/2025 POWER SOURCE REVISION WARNING GNATI iRE 7INVERTER . NOT PV-5 RELOCATE THIS OVERCURRIENT DEVICE LABELS CONTRACTOR ELEMENT ENERGY SOLARI BATTERY BACK UPI 631,77-379931 E2SYS.0 OM ENGINEERING DRAWINGS I MECHANICAL CHARACTERISTICS ELEMENT ENERGY LLC S rtir B A t to 1 No.of Hatt Cells 108 12 x SLl 7470 SOUND AVE, _. � t6B6mm�68_�_ ! Dimensions 1722 x 1134x 35mm(67.79 x 44.65x 1.38 inch) MATTITUCK, NY 11952, USA We,ght 2Z01,9(43.5tbs1 +1 631 760 7262 ' Front Glass 3.2mm.Anti-Reflection Coating LIC TYPE: HOME High Transmission.Low Iron,Tempered Glass IMPROVEMENT, MASTER Frame Anodized Aluminum Allcy ELECTRICIAN ' - - Junction Box IP68 Rated Output Cables 12 AWG.1400mm 155.12in1 or Customized Length LIC NO.: 67461-HI, 52689-ME Connector Staublt MC4 • �. Fire Type Type 1 PROJECT INFO 8 ADDRESS !. Pressure Rating 5400PalSnowl&2400Pa(Wind) ROBERT KELLER EAGLE`' 54 G6R - I r- 380 KNOLL CIR, j TEMPERATURE CHARACTERISTICS EAST MARION 420-440 WATT - N-TYPE TOPCON TemperatureCoeffidentsofPmax 0.29°nl°C Length:x 2mm I POSILIV2 OWef 10�13f8f1C2 Of D^+3010 Width:t2mm Temperature Coefficients ofVoc -0.25%/°C NY 11939, USA t' Height::lmmi Tempest---ffic.ents of tsc 0.045%/°C SYSTEM SIZE P n How Pitch:t Ymm Nominal Operating Cell Temperature(NOCTI 45t2•C DC SIZE: 12.470 KW DC-(STC) • NYSE-listed since 2010.Bloomberg Tier 1 manufacturer - - AC SIZE: 9.280 KW AC • Top performance in the strictest 3r"party tabs ELECTRICAL PERFORMANCE&TEMPERATURE DEPENDENCE MAXIMUM RATINGS • Automated manufacturing utilizing artificial intelligence ur,ent-Vottage&Power-Vottana Tern.rerature Dependence Operaing Temperature l°CI -40°C-«65°C • Vertically integrated,tight controls on quality Cur-144DVA a '"'..vo-,Pmax Maximum system voltage 1000VOC I : • Premium solar factories in USA,Vietnam,and Malaysia Maximum Series Fuse Rat no 25A� to-- --- ! KEY FEATURES 'tY PACKAGING CONFIGURATION Superior Aesthetics (Two pallets=One stackI O Bt ack r "a efack frame create ides)took for - _- - ° - 31pcs/pallet=_.62pcs/stack,306pcsi40 HO Container • tc .s x i• as reside tial aoDti aeons O N Type Technology : N L od l�J rko s n-pause TOPCon tech • �sp=��t,=: gY WARRANTY offers better performance and Improved rebabitity Celi Temperature I°Cf � I 25-year product and 30-year linear power warranty ro,cx Thick and Tough i 1"year degradation not to exceed 1%.each subsequent year not to Fire Type' rates module eneineered w tr a thick frame, exceed 0.4%,minimum power at year 30 is 87.4%or greater. 3.2mm front side glass,and thick backsheet for added durability. Shade Tolerant ELECTRICAL CHARACTERISTICS Iwin Errar desicn allows continued performance Module Type JKM420N-54HL4-B JKM425N-54HL4-0 JKM430N-54HL4-a JKM435N-54HL4-0 JKM440N-54HL4-0 e+en with sradmg by trees or debris. " STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT �-Q Protected Against All Environments Mall PmNer(Pmax; 420Wp 316Wp 425Wp 320Wp 43cW0 323Wp 435wp 327Wp 44LWp 331W'p rail':,marine envirorinnents. Maximum Power Voltage Ili 32.16V 29.95V 32.37V 30.19V 32.58V 30.30V 32.78V 30.5011 32.99V 30.73V w_nd,�aastcrrns,and packed srov;. Maximum Power Current(imp) 13.06A 10.55A 73.13A 10.60A 13.20A 10.66A 13.27A 10.72A 13.34A 10.77A OWarranty Open-circuit Voltage Wad 38.74V 36.80V 38.95V 37.00V 39.16V 37.20V 39.36V 37.39V 39.57V 37.59V i year prodU--t and 30-year linear power Warranty. Short-circuit Current tlscl 13.51A 10.91A 13.58A 10.96A 13.65A 11.02A 13.72A 1'.08A 13.80A ?i 14A Module Efficiency STC1%1 21.51% 21.76% 22.02% 22.28% 22.53% *STC: • irradiance 1000W./m . Cett Temperature 25°C 6 AM-1.5 DRAWN BY AK AM-1.5 Wind Speed im/s DATE 10/25/2025 • Iso9col 2D75 odd q S andartls 15045001:20160ccupa;ionai O ® NOCT: a Irradiance 800V�!m' t Ambient Temperature 20`C � - - P • 16014001.2015 Ervironmenlal Standards Health&Safely Standards �--, CE C us 'Power measurement tolerance:i3°a • IFC61'15 IEC6173.-. er ified prcdu-ts UL61730 certified produ,_ts LISTED - The company reserves the final noht to;explanation on anv of the!nforrnaoon p-eserled hereby JKM400-420N-56H1_1-5-=1 U5 REVISION BUILDING YOUR TRUST IN SOLAR.WWW.JINKOSOL.AR.US S f linKQ BUILDING YOUR TRUST IN SOLAR WWWJINKOSOLAR.US ,J(j'i�<Q �GtvfrT uRc PV-6 RESOURCE DOCUMENT CONTRACTOR ® ELEMENT ENERGY SOLARI BATTERY BACKUP 1631.779.79931 E25yS.COM u ENPHASE. IQ8MC Microinverter ELEMENT ENERGY LLC INPUT DATA CDC) UNITS 108MC-72-M-US 7470 SOUND AVE, Commonly used module pairings w 260-4bU MATTITUCK, NY 11952, USA _MPM wModuk:compatibility +1 631 760 7262 To meet compatibility.PV modules must be within the following max.input DC voltage and rnax.module Ix pa y Module compatibility can be checked at https://enphase.comlinstaNers/mirrdnverters/c".ulator. LIC TYPE: HOME MPPTvohagerange v 25-45 IMPROVEMENT, MASTER ELECTRICIAN -- Operating range v 18- LIC NO.: 67461-HI, 52689-ME Min./Max.start voltage v 22/58 Max.mput DC voltage v 60 PROJECT INFO&ADDRESS Max.continuous operating DC current A 14 Max.input DC short-circuit current a 25 ROBERT KELLER Max.module IF A 20 Overvoltage class DC port 11 380 KNOLL CIR, DC port backfeed current mA C EAST MA RI O�+N, PV array configuration Ungrounded array;no additional DC side protection required;AC side protection requires max 20 A per branch circus NY 11939, USA SYSTEM SIZE Peak output power VA 330 315 DC SIZE: 12.470 KW DC-(STC) Max.continuous output power VA 320 310 AC SIZE: 9.280 KW AC Nominal grid voltage(L-L) v 240,split-phase(L-L),180• 208,single-phase(L-0.120" 1 Q 8 M C Microinverter Easy to install Min./Max.grid voltage= v 2n-264 183-229 id-1 orming',software- Lightweight and compact with plug- Max.continuous output current A 1.33 1.49 defined microinverters with split-phase power conversion capability to convert DC power to and-play connectors Numinal frequency H: 60 AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary Power line communication(PLC) Extended frequency range to 47-68 application-specific integrated circuit(ASIC),which enables the microinverter to operate in between components grid-tied or off-grid modes.This chip is built in advanced 55-nm technology with high-speed Faster installation with simple two-wire AC short circuit fault current over three A 270 digital logic and has superfast response times to changing loads and grid events.alleviating cabling cycles " constraints on battery sizing for home energy systems. Max.units per 20 A(L-L)branch circuit 1 12 10 High productivity and reliability Total harmonic distortion % <5 Produces power even when the grid is down' Overvoltage class AC port III • More than one million cumulative hours AC port backfeed current mA 18 of testing Power factor setting 1.0 Part of the Enphase Energy System, IQ8 Series Microinverters redefine Class II double-insulated enclosure Grid-tied power factor(adjustable) 0.85 leading...0.85lagging I08 Series Microinverters integrate with reliability standards with more than one Optimized for the latest high-powered the IQ Battery,IQ Gateway,and the million cumulative hours of power-on PV modules Peak efficiency % 97.4 97.2 Enphase App monitoring and analysis testing.enabling an industry-leading CEC weighted efficiency % 97.0 96.5 software. limited warranty of up to 25 years. Mierogrid-forming Nighttime power consumption mw 33 25 Complies with the latest advanced grid MECHANICAL 13ATA UNITS support Ambient temperature range -40°C to 65'C(-407 to 149°F) Remote automatic updates for the a latest grid requirements Relative humidity range 4%to 100%(condensing) • Configurable to support a wide range DC connector type Staubli MC4 Connect PV modules quickly and easily IQ8 Series Microinverters are UL Listed of grid profiles Dimensions(H•W•D):Weight 212 mm(6.3')•175 mm m(6.9")-30.2 m (1.2");1.1 kg(2.431bs) to the I08 Series Microinverters that have as PV rapid shutdown equipment and Meets CA Rule 21(UL 1741-SA)and IEEE Cooling Natural convection-no fans integrated MC4 connectors. conforms with various regulations when 1547:2018(UL 1741-SB) Approved for wet locations;Pollution degree yes:PD3 installed according to the manufacturer's instructions. Enclosure Class 11 double-insulated,corrosion-resistant polymeric enclosure NOTE: I08 Microinverters cannot be mixed together wth Environ.category;UV exposure rating NEMA Tyoe 6;outdoor previous generations of Enphase micrdnverters COMPLIANCE DRAWN BY AK (10:Series.106 Series.etc.)in the same system. 'Meets UL T741 only wnen insta8ed with 10 system Controller 2 and 3. 10 Gateway is requred to change the defaur,grid CA Rule 21(UL 1741-SA).UL 62109-1.IEEE 1547:2018(UL 1741-SB).FCC Part 15 Class B.ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 profile at the time of mstallatior to meet the local Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014.NEC 2017.NEC 2020,and NEC 2023 section 690.12 and DATE 10/25/2025 Authority Having Jurisdiction(AHJ)requ:remehts. C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's instructions. 0 2023 Enphase Energy.All rights reserved.Enphase.the a and CC logos.IQ and certain other marks listed at REVISION (1)Nc enforced DC/AC ratio. https..'�er�tase.com:tradsnark-n ge-gr.iaelmaa are trademarks of Enphase Energy,Inc.it the US and other countries. (2)Nominal vokage range can be extended beyond nominal it required by the utility.Data subject to charge. IQBMC-MC4-DSH-00049-3.0-EN-US-2023-10-I8 (3)Limits may vary.Rater to local requirements to define the number of microaverters per branch in your area. IQBMC-MC4-DSH-00049-3.0-EN-US-2023-10-18 I G NA I U R E PV-6.1 RESOURCE DOCUMENT CONTRACTOR ELEMENT ENERGY SOLAR I BATTERY BACKUP I631.779 79931 E2SYS.COM ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER IQ Combiner 5/5C ELECTRICIAN ENPHASE ® 3:.5<m.dg.5rma,6.6<m(,<.s•.o.5•.a83•).H.� .2�8(SS.S�,wthmn tine LIC NO.: 67461-HI, 52689-ME Dimensny,s(Ww.C) Drerlets r We�yln T,'j agda.5luN ,r-- _.-___.-,�„ hacomb„e�swn„,uuamwaYwmted<�r<„n,p,.•a(er�mag=aredra,an�egndewprman An,eamtampanwreranpa ao-C,ods•c(-do'Ftons'F) PROJECT INFO&ADDRESS :t:Goer>inc.5(%-IG-0.MrT40.5) -rc(ANSICI220 sp.5"b).<orcumwipn monitorvp(125b)a,d WBattwYrronibrirg(L'.5'di. ,�5asayarsalaral;eatP<a,k<t„a.t �pdinc N.t�nlcpn.�e<Yw,.waalwe,ahkld 3R.r ,_ , ROBERT KELLER 1]C7•nbino�SC wit,bGateway Primal cio�rt—d fro m<prAtad nvoms arse.P�'produo[ion �...� eenvlronrtwrtta.anng Outaow, N NGTL-cer:A)ed. EMA type pclycarbenata crostrumon Q Comaner SG(%H T-24B-SC) enr:nG(AHSt C1220 (2.5%)a td lO Battwy mo-wV(✓25%). ,tholes ErryhAae ktobk Cwvwet c ibWar noda,n ICELLMOCrENJn-I)6-SP-OS),Inc�udm a saver 20 A to50 A broker Iryuts:uto a qWG cooper cpnduemn a l snkld m d~t Mat 50 A baakw March—It.4 to 1/0 AWG rn l Corauc,ws Wne r�xea Mein lug carnbkredovfart:10 b2.'O sale cappercoMumon Nwan:andg=cundum)m«,ope=wne�noR 380 KNOLL CIR, 4MaYs vlkwbca cote requi,emer,ta ier conductor r(zin6 anwarp nte.ee pabpad bG.tew.e„~tM=clnaymw%IOaSaya.[M.n 9Yma�g.»m wc�m«.,..r.m�ema�..n e.n ,emmu,�crtron(Imprenise eonna:Lvrty) (E '^�Tq,FnaMInwwMnrxnnxxrcMnnw + aarv.+ aM EAST MARION,mgm o = 12A bumbar wahi p Ibo.t atO Gat— 4a2Qs braaw for—.6e, SaMs hlwPand Power Lms Communke:fpn M1dr Nl SerMS MkronveYera Mw,wwer..—Toaanwv5P _ Uptp 2.600me4m(a.53(l feed NY 11939, USA Ia 3anwer broaker Circuit b•enam.2-Pole.tU A1150. SYSTEM SIZE Production CT Prewired revarws-grade-w CT,actt=an up tc OS% ntegratec Wi-F e0211bJg/nldual 1-12.43Hz/5GHxl.fw cr,rwctmq the Erptraae coos Na the irate:met X-10-AMi-240-5 bw C CT tp2 i %-IQ-AM}240-SC Consumptan ,w�<pinpmm�nma:er nC�amp Ta.shipped w:tR ttw .xun,e up 'v: w(, DC SIZE: 12.470 KW DC-(STC) anaa(rawmmended) �o m q 9atwrYCf One pn,tery metertg damp CT.-11.wl:h iM bm.accunn upto 2.5R y,-11, BLE42,Wmra,da:o configwe WH-FI SSID AC SIZE: 9.280 KW AC Q Combiner 5/5 C CTRL b is Coniro:boat I,,.,ad rommunicat—wit,lO$rsten C-rrciinr 3/3G and the 4 ..,b; `b e Optbna BO 3.CaIm for Cat 5)UTP Ethernet Cabe(rrot..nciudetl).for connecting M the EfpMre Mobile fmner+ !`.omMrerSr; dG Gesed LlE sh eel wa.maden(CELLMCDEM-a41-O6-5P-OS)wilh a5-year i UnE+.data plat. Et— 1 d Me rat"-! Smart ot„[soars for GIRL bone uodk Connect CELLMODEM-An-OS-SP-0Sp CE-LMODEMi.(1- BAT-05(hnrtlacw IQ Canbi,er 5C) The lO Conbinar 5/5C consolidates in'erconrrectwn ecuipmen:solos A"Rb erdpsUr9and °-- � - --•r streamk a105 ,Ies Ufic ryerters and 10 Gateway installaticn by providing a.srsistem. '-wdevo Gx,eway for l.t, Ugrtal mput/outpnfor grlc openwr c�nvd pre wired edudon tw micl,.tial epplicetiom.IQ Ccmbi 5/SC uses wired contnl —.—etan end--i ACCESS.�!ES AND REPLACEMENT PARTS 1*01 INCLUDED,D�I)El USB2.0 Fro Mote Conrwar oo —matior and is—o atible with IO Syat—ConboKer 3/3G and 10 Battery 5P •Includes krphase MobAe Connect �CLLMGD[M an C6 SP o9 .0 based LTC an 5 T Mobia dma al.n (--ELLMODEM-1106-SP-05).-1, CELLNDDEM-MI-CO-At-O$ dG-based L)E-N+.c 4 4 modem with 15-✓ea1 AT&T data per. d-cess Col+r(A>)n,d- Fx romwCuonrntwwr,tM lOGa:eway aM a mebiedrrW<e torso tM Enphaaa—at.,A- The 10 Combiner 5/5C,eiwtg with IQ Series Miooimerters 10 System ConboBar 3/30.and with IQ Combiner 5C Metering parts lip to Tw Cprnuaspticr Crs.ore 10 Battery CE am one Produttbn 0 IQ Battey SP provides 111 a complete grid-agnostic Enphase E,rargy System. Supports flaslble networklrg:Wl-F, Qrcun beekem(of-dre- a") Sup i Ea:pn 9R210.BR25.BR220.BfY230.BR240.BR2SO.eras 0R260 ckurt heaeen Eth—L w copular Supports Ea•.on SR22GF B923M.mW 3R24CS mot breakers Cpmwtbk-th hold-down aft ow...gym mmmun cA.on �lU-r1U:Hz W7 Prrnides Productbn metering CImlAr erea4rs(Pruviced WEnphase; C401',BpMoe deiabKinSAAcceanrtaBs-secfanp-2a0V lIRK-154-2:>_240V-B.uW 3RK-20A-2P- `Nat AP Reim toMaislms-rI (rave w grad<l ertd coroumption —M-mg rd-S(N ARSYpF.DES P.a,Ycrawwe mnr aW d In In Cnrnbinnr 5/!SC _ Refa�togidc b tri:APt SA-[NYC-V�BC-S t:�'vafeway'eP,t<emerS prnte4 cncu„trwr0(V:;B)fcr t:omtmar J r,K; Easy to�� K-10-NA-NC-125A Had-down kt cempatibe witfr E.I.BR-B series rota[breakers(wit^screwsi _ UL 1741.CAN/CSA CM No.M.t.'ine 47 CFR Part 15 Class B.ICES 003 IQ Series M-crdrnertera 10 Sotsm Controller 3/3Ca Mowls to one stud with centered The hgh-powe:'red srnart grid-ready IQ 5erles Provides miCrogrd bltercpnrlectdn brackeb (IL.em-tiCANCSA 222 Na.61mD-i.IEEf YU4]:2Gb(UL)]41-58.Y Edl Mcroiri—9Q6.107.and 108 aeries) device(MtD)fcnctiomlrty b) Supports bottom.back.and side Rati 60 A - SEE 2olG.5/C9ro Cc. l-- dnmaticall-si lif the installaior automat wl datacii id failures and C prosuc'ton l,wterinp:NbI T20 accnrxy class 0.51PV productwn) mP Y p=.teas , 'W 9= onduit entry ssamlenlY transaoneg:)re home en"Ry 5rsrem yohsge 120/240 VAC,80 Hz system Iron grid pools,M backup power Supports up W four 2-pole branch =its for 240 VAC pbrg-m breakers Brabw mrnp t25A -- SCp00111C2401f501.SCZOMTIC240US0t -- rtotndudedI Feu`p `ra,mg 10kAc K]BATTERV-5P-W-NA -� BO A Total PV branch Circuits Makmum corrtinuoos cxrerrt ntmg(irrotztlrom PV/rtorape) a4A .. IO6.IQ1 aM 10a SaW Yic.omwrara Bluetocth based Wi Ft p—isiming forces)Wi-Fisetup Bnrrch cacarts lsoar a:d/or storage) Up co tow 2-pole Caton FAtfwles detnnuttl gereraLlmf(;Gl baaters onY(rapt mc.uee Madmum total br—hdreat treater rabg 0i 1) 60 A of datrbutsd perw —95AwM IC Gai—breakerV lad Reliable '.p Grtewa'i lxaaFe. iDA>r 15Arnnng GE/$rmenalEalpn included Durable NRTL—lified NEMA type 3R ...I Lfe Productior"t'stari+3 C' 200Aso4d cwa pn-imnYed a.,d wirW to IQ Getaway I0 Battery SP IQ Load Controller POT,Megrwad AC battwy systam.Inekrdas spa -1,prioritize ease—I Ppti—.- 5-Veer iirtxted werrerty ..prwmptien monirormg CT iCi-200-CLAW, Apau of 2lXrANanp-s.Yle curnntirartsb-mo-�s is incMdad whh t,e COK fieldKeyaeeable 10SC-13AT Microlnv— d,6,g a grid o-9,to optima Twoy,awslaborrambursement 00.yttery metw'xra LK 2GG4 tromp-atmbcwmnrranafwmer fwi00anerr rwtenrp.mciuded wk„tMboy energy coreumption anc prolorg M.la—cnvwage inck,dad I-troth battery life the IQ Combiner SKUs UL77dT ksted N Lam O 5 Ymr -apM9am-,wniwsew ga4eew'>•<awn ter systan W to 6'l marar..eruv I•ava:aae a,x us.code Aleneo Puwto Biro.+M iM limited us 9n wra:.wwr.mweu s4eonre rw:w:rerve.mnw wmnwrron er.a.; 62023 Enphase Enspv-4Il rp„ts raaerwd.Erap„ax.de a arlc CC boos.F1 a,tl cerLm,the rrerb-utetl at Mrs://avlraaesomltr�etead-usepe-orneekea are natlemarks of Et l—Eraag,mc.m the USWo:Mreoan1— De[a sub)ect^o champs.. roc-}SC-D6Nd0pp1-:A-e+-tu-TJt3-o9T Ip•'.SS:.-JSH.Uppq]-2.0-FN-lS-2p2}pp2r 10:-SSC-0BN- 2L-=N- - r DRAWN BY AK DATE 10/25/2025 REVISION ->IGNATURE PV-6.2 RESOURCE DOCUMENT CONTRACTOR ELEMENT Air IRONRIDGE Al Aire Rail BA ® ENERGY SOLARI BATTERY BACKUP 1631,779.79931 E2SYS.COM ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME SEE DESCRIPTION IMPROVEMENT, MASTER ELECTRICIAN LIC NO.: 67461-HI, 52689-ME PROJECT INFO&ADDRESS 1 ROBERT KELLER 380 KNOLL CIR, ITEM NO DESCRIPTION QTY IN KIT EAST MARION, NY 11939, USA 1 AIRE RAIL, A1, BLACK(OR CLEAR), 170" 1 SYSTEM SIZE DC SIZE: 12.470 KW DC-(STC) AC SIZE: 9.280 KW AC PART NUMBER DESCRIPTION AE-Al-170B AIRE RAIL, Al, BLACK, 170" AE-Al-170M AIRE RAIL, Al, MILL, 170" 1) AIRE Al RAIL.SECTION PROPERTIES 1.40 PROPERTY VALUE �1.17� TOTAL CROSS-SECTION AREA 0.364 in SECTION MODULUS (X-AXIS) 0.146 in' MOMENT OF INERTIA (X-AXIS) 0.126 in W1.04 170MOMENT OF INERTIA (Y-AXIS) 0.114 in4 TORSIONAL CONSTANT 0.001 in. POLAR MOMENT OF INERTIA 0.239 in PART NUMBER MATERIAL FINISH DRAWN BY AK AE-Al-170B 6000 SERIES ALUMINUM BLACK DATE 10/25/2025 AE-Al-170M 6000 SERIES ALUMINUM CLEAR REVISION SIGNATURE v1.10 PV-6.3 RESOURCE DOCUMENT CONTRACTOR ® ® ELEMENT ENERGY SOLAR I BATTERY BACKUP 1631.779.79931 E25YS.CCM ®Mk IRON RIDGE End Fastening Object ®AE. IRONRIDGE Universal Fastening Object® ELEMENT ENERGY LLC Only7470 SOUND AVE, accord wor ith written and use withs e IronRidge.com/UFO products in MATTITUCK NY 11952 USA accord with written instructions see IronRidge.com/UFO > > +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN e LIC NO.: 67461-1-1I, 52689-ME PROJECT INFO 8 ADDRESS ROBERT KELLER UNIVERSAL FASTENING OBJECT® 380 KNOLL CIR, EAST MARION, PART NO. DESCRIPTION NY 11939, USA UFO-END-01-Al END FASTENING OBJECT(END CLAMP,30-40mm),MILL SYSTEM SIZE DC SIZE: 12.470 KW DC-(STC) UFO-END-01-B1 END FASTENING OBJECT (END CLAMP,30-40mm),BLACK AC SIZE: 9.280 KW AC 1 .43 -1.0� ITEM NO. DESCRIPTION UFO CL 01-Al UNIVERSAL MODULE CLAMP, CLEAR - -01-j39 I 1.27 COMPATIBLE WITH .5B 30-40mm MODULE FRAMES 2 .29 7/16'Head .61 �— •25 COMPATIBLE WITH 0.37 Uc 30-46mm MODULE 4 FRAMES 1.0 01.12 7116"HEAD .97 O .25 Property Value ITEM NO. MATERIAL FINISH Material 300 Series Stainless Steel 1 6000 SERIES ALUMINUM MILL OR BLACK Finish Clear and Block DRAWN BY AK 2 300 SERIES STAINLESS STEEL CLEAR AND BLACK v1.0 v1.32 DATE 10/25/2025 REVISION SIGNATURE PV-6.4 RESOURCE DOCUMENT CONTRACTOR ® ELEMENT ENERGY saLAR I BATTERY BACKUP 1631,779.79931 E25Ys.COM AML IRONRIDGE Bonding Hardware Air. IRONRIDGE Grounding Lug ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME 3 3 1 IMPROVEMENT, MASTER 2 ELECTRICIAN 1 3 LIC NO.: 67461-HI, 52689-ME ® 10 2 PROJECT INFO&ADDRESS ROBERT KELLER ITEM NO. DESCRIPTION 1 BOLT,T CSTM,3/8-16 4 380 KNOLL CIR, 2 BOLT,BONDING 3/8-16 SG HEAD ITEM NO. DESCRIPTION EAST MARION, 3 NUT, BONDING STEP 1 LUG,GROUNDING,LAY-IN-LOW PROFILE NY 11939, USA 2 BOLT, 1/4-28 X.750"HEX CS SST SYSTEM SIZE BONDING HARDWARE 3 NUT,FLANGE HEX 1/4-20 SST DC SIZE: 12.470 KW DC-(STC) 4 BOLT,T CSTM 1/4-20 X 1.188"LOCK SS AC SIZE: 9.280 KW AC Part Number Description BHW-TS-02-Al T-BOLT,BONDING HARDWARE Part Number Description Wire Size Range(AWG) BHW-SQ-02-Al SQUARE-BOLT,BONDING HARDWARE XR-LUG-03-Al GROUNDING LUG, LOW PROFILE 4-10 1) BOLT, T CSTM, 3/8-16 2) BOLT, BONDING 3/8-16 SQ HEAD ])Lug, Grounding 3) Nut, Flange Hex l 14-20 .82 1.00 � 1.00 .63 3/8-16 TH D i F63 71 1/4-20 THD 0.59 .36 .56 0.26 "Head --M—.24 .29 � 2 � �--- �V 3/8-16 THD f--1.75--I Property Value Property Value Property Value Property Value Material 300 Series Stainless Steel Material 30D Series Stainless Steel Material 300 Series Stainless Steel Finish Clear Material Tin Plated Copper Finish Clear Finish Clear Finish Clear Matte 4) Bolt,T CSTM 1/4-20 x.750 3) NUT, BONDING STEP _J_ .24� 1/4-20THD 3/8-16 THD 2) Bolt, 1/4-28 x.750 Hex 0.75 7/16" .16 .61 I ® ( 1 Head 1/4-28 THD .26— —►I .75 �— V .75 r 7116"Head 79 Property Value Property Value Property Value Material 300 Series Stainless Steel Material 300 Series Stainless Steel Material 300 Series Stainless Steel Finish Clear Finish Clear DRAWN BY AK Finish Clear DATE 10/25/2025 0.30 v1.10 REVISION SIGNATURE PV-6.5 RESOURCE DOCUMENT CONTRACTOR ® ELEMENT ENERGY S13LARI BATTERY 13ACKUP1631.779.79931 E2SYS,Cl3M ®-L IRONRIDGE UFO' Family of Components System Diagram ELEMENT ENERGY LLC 7470 SOUND AVE, -- - - - -_ - - MATTITUCK, NY 11952, USA +1 631 760 7262 Simplified Grounding for Every Application ) _ - _ _._ _ _ _ _ _ _ _ -m_ _ _ _ _ __ IMPROVEMENT, MASTER_ _ _ _ _ _ TYPE: HOME �-•-� - - The UFO'family of components eliminates the need for ELECTRICIAN separate grounding hardware by bonding solar modules _ directly to IronRidge XR Rails`.All system types that LIC NO.: 67461-HI, 52689-ME 4 feature the UFO'family—Flush Mount',Tilt Mount®and " Ground Mount®—are fully listed to the UL 2703 standard. _ _ _ PROJECT INFO&AUURESS - - - - - - - - - - - - - - - - - - - - - - - UFO�'hardware forms secure electrical bonds with both the - - - - - - - - -�- - - - - - - - - - - - - - - - - - - ROBERT KELLER module and the rail, resulting in many parallel grounding paths throughout the system.This leads to safer and more __ __...r._ _ :_ _, _. _- _ . __ _ .__ _ 380 KNOLL CIR, reliable installations. EAST MARION, Only for installation and use with IronRidge products in accord with " - - - - - - -,- - - - - - -- - - - - -- - - - - - - - - - - - - - - - - ' NY 11939, USA written instructions.See IronRidge.com/UFO .,t; SYSTEM SIZE l ' DC SIZE: 12.470 KW DC-(STC) AC SIZE: 9.280 KW AC +� Universal Fastening Object(UFO°) Stopper Sleeve The UFOI securely bonds solar modules to XR The Stopper Sleeve snaps Rails"-It comes assembled and lubricated.and _ _ _ _ _ _ _ _ — _ _ _ _ _ _ _ _ _ _ _ _ 7 -7 — _ — — onto the UFOa•converting it can fit a wide range of module heights. i _ _ _ _ ___ _ _ _ _ —'— _ — _ _ _ _ _ _ _ _ — _ _ _ _ _ - — _ _ _ into a bonded end clamp. I Q UFO Stopper Sleeve • Grounding Lug m BOSS'" Splice -1- Ground Wire f IronRidge s ems eliminating'�,�� ,,�•�, �'<;:�: v`-,.," 4 Approved Enphase microinverters can provide equipment grounding o systems, g the need for grounding lugs and field installed equipment ground conductors(EGC).A minimum of two microinverters mounted to the same rail and connected to the same Engage cable is required.Refer to installation manuals for additional details. \,% ! � UL Certification _ Compatibility, The IronRidge Flush Mount, Tilt Mount®, and Ground Mount XR Rails" d d XR100&XR1000 BOSSO Splice -�f Systems have been listed to UL — — Bonded Structural Splice ; ` 2703 by Intertek Group plc. UFO /Stopper Vp d — connects rails with built-in bonding teeth.No tools or �< OF 80SS�Splice d d N/A hardware needed" UL 2703 is the standard for evaluating solar mounting Grounding Lugs 1 per Row 1 per Row 1 per Array systems. It ensures these devices Microinverters will maintain strong electrical and &Power Compatible with most MLPE manufacturers. Grounding Lug mechanical connections over Optimizers Refer to system installation manual. A single Grounding Lug Bonded Attachments connects an entire row The bonding bolt attaches an extended period of time in Fire Rating Class A Class A NIA DRAWN BY AK of PV modules to the and bonds the L-footO to the extreme outdoor environments. g -- grounding conductor. rail.It is installed with the Refer to installation manuals for a detailed list. DATE 10/25/2025 Tested or Evaluated with over 400 Framed Modules same socket as the rest of the Modules System. Q Go to IronRidge.com/UFO REVISION SIGNATURE 20221ronRldge,Inc.All rights reserved.visit:,www.ir-patents,corn forpatent Inf ormatio mVersion 1.23 PV-6.6 RESOURCE DOCUMENT CONTRACTOR 110MELEMENT ENERGY ® SOLARI BATTERY BACKUP1631.779.79931 E25YS.COM ELEMENT ENERGY LLC AA-L IRONRIDGE QuickMount' Halo UltraGrip 1.Halo UltraGrip 38 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN LIC NO.: 67461-HI, 52689-ME PROJECT INFO&ADDRESS 3.35 RD STRUCTURAL SCREW PN RD-1430-011-M1 ROBERT KELLER SOLD SEPARATELY \h SHOWN FOR REFERENCE 380 KNOLL CIR, EAST MARION, NY 11939, USA SYSTEM SIZE Release Liner shown for reference DC SIZE: 12.470 KW DC-(STC) I AC SIZE: 9.280 KW AC 3.83 — 0 0 0 .40 �-- .26 O 1.63 1.56 I ITEM NO DESCRIPTION QTY IN KIT 1 QM Halo UltraGrip(Mill or Black) 14-9 1 O O .34 PART NUMBER DESCRIPTION QM-HUG-01-M1 Halo UltraGrip-Mill QM-HUG-01-B1 Halo UltraGrip-Black 3.00 Property Value Material 300 Series Aluminium ^ DRAWN BY AK Finish Mill or Black (��[ DATE 10/25/2025 ©2022 imnRidge,inc.All rights reserved Visit vrvnvJr-patents.com for patent informalion. QM-HUG-01-B1 or QM-HUG-01-Ml Cut Sheet Rev 1.0 02022 IronRidge,Inc.All rghts reserved.Visit w nvir-patents.com for patent information. QM-HUG-01-Bl or OM-HUG-01-Ml Cut Sheet Rev 1.0 REVISION SIGNATURE PV-6.7 RESOURCE DOCUMENT CONTRACTOR � � ELEMENT ®�� IRONRIDGE QuickMount® RD Structural Screw ENERGY 50LARIGATTERY BACKUP I631.779.7993INSY5.00M ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11952, USA 2 +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN LIC NO.: 67461-1-11I, 52689-ME PROJECT INFO&ADDRESS ROBERT KELLER 380 KNOLL CIR, EAST MARION, ITEM NO DESCRIPTION CITY IN KIT NY 11939, USA 1 Self Drilling Screw,#14,Wood Tip 1 SYSTEM SIZE 2 Washer, EPDM Backed 1 DC SIZE: 12.470 KW DC-(STC) AC SIZE: 9.280 KW AC PART NUMBER DESCRIPTION HW-RD1430-01-M1 RD Structural Screw 1.Self Drilling Screw,#14,Wood Tip .22 #14 DIA 5/16"Head 0.43 3.00 Property Value Material 300 Series Stainless Steel Finish Clear 2.Washer, EPDM Backed .13 0.26 0.57 DRAWN BY AK Property Value DATE 10/25/2025 Material 300 Series Stainless Steel ^ REVISION Finish Clear `"YC SIGNATURE ©20221ronRidge,Inc.All rights reserved.Visit wwmir-patents.com for patent information. CIM-M-RD-1430-01-M1 Cut Sheet Rev 1.2 - PV-6.8 RESOURCE DOCUMENT