Loading...
HomeMy WebLinkAbout52937-Z QF�II�r TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD., NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52937 Date: 05/01/2026 Permission is hereby granted to: Jeremy Lamande 480 N Bayview Road Ext Southold, NY 11971 To: construct an accessory in-ground swimming pool as applied for. Premises Located at: 480 N Bayview Road Ext, Southold, NY 11971 5CTM#78:9-41 Pursuant to application dated 04/21/2026 and approved by the Building Inspector. To expire on 04/30/2028. Contractors: Required Inspections: Fees: SWIMMING POOLS-IN-GROUND WITH FENCE ENCLOSURE $300.00 CO Swimming Pool $100.00 Total $400..00 Building Inspector T [l " 8( I1THt LI --BUILDING DEPARTMENT Al"N o Tarn Hall Annex 54375 Main Road P. i�J►. Box 1179Southold,NY 11971-0959 N V r Telephone (631) 765--1 02 Fax(631) 765-9502 � 4 .so li r Date Received APPLICATION For office Use only k I w PERMIT NO, Building Inspector': �ti I � � �� Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: 4/15/202 OWNER(S)OF PROPERTY: Name: v nsvn SCTM#1000-78.-9-41 Sara Le e Project Address:480 North Bayview Road Extension Phone#:917_751-5880 Email: aralmaher@gmail.com Mailing Address:480 North Bay view Road Extension, Southold, NY 11971 CONTACT PERSON: Name:Sara Levenson MailingAddress:4 0 North Ba view Road Extension, Southold, NY 11971 S Bay view #:917-751-5880 Email:saralmaher@gmail.com DESIGN PROFESSIONAL INFORMATION: Name:Dina Ferraiuolo, PE Mailing Address: 101 Garfield Place, Brooklyn, NY 11215 Phone#:917-998_306 0 Email:dinagdmfengineering.com CON TRACTOR RACTO R INFOR MATION: Name: specht-Tacular Pools Mailing Address: 255 Brookfield Avenue, center Moriches, NY 11934 Phone#: 631-596-3900 Email: Elkeb@specht-ta,cularpools.com DESCRIPTION OF PROPOSED CONSTRUCTION Addition FlAlteration F�Pe air ❑Demolition Estimated Cost of Project: ❑Neuv Structure ❑ p 67,000 ❑other �"e"in round pool Rig Will the lot be re-graded? Yes ❑NoWill excess fill be removed from premises? DYes A No PROPERTY INFORMATION Existing use of property:residential Intended use of property:residential Existing Zone or use district in which premises is situated-, Are there any covenants and restrictions with respect to R_40 this property? FlYes ®No IF YES., PROVIDE A COPY. R Check Box After Read i ng: The owner/contractor d esign professional is responsible for a I I d ra i nage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,,ordinances.,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.4S of the New York State Penal Law. k,r + Application Submitted By(print mp); AAuthorized Agent E]Owner A Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF I r being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing C,,ntract)above named, (S)he is the (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 7 At AL*1, day of 20 42.- Notary Public CHRISTINA DIANNE PARISE PROPERTY OWNER AUTHORIZATION FN(ffTARY PURL1( STATE OF NEW YOR'' I Registration No.O1PA6415578 (Where the applicant is not the owner) Qualified in SU I gn,,j '' I My Commission Expires 2 L 10, 1 I, „ Y'CJI. v re sid i ng at gcea, do hereby authorize I ), to apply on my behalf to theU, of Southold Building Department for approval as described herein. e 0 of Southold 151 Owne,the Date Sara Levenson Print Owner's Name 2 ley 143 BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD � t_A tg ° Town Hall Annex - 54375 Main Road - PO Box 1179 ti Southold, New York 11971-0959 ,. ��� Telephone (631) 765-1802 µ VM q APPLICATION FOR ELECTRICAL INSPECTION ---------------------------------------------- ELECTRICIAN INFORMATION (All Information a uired) Date: Company Name [Electrician's Names ID c , tref e License No.: Elec. email. M Elec. Phone No: I request an email copy of Cer lfic e, of Compliance f�� Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: Address: Crass Street: Phone No.: 1 - -- " W Bldg.Permlt#: email: M Tax Map District: 1000 Sections Block: Lot:................................ ONNNNNOMM" Vill IF IN M BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): W� (e Pool Sq ,;are Footage Circle All That Apply: Is job ready for inspection?: YES [:XNO Rough In E:1 Final Do you need a Temp Certificate? YES NO Issued On .................................. Temp Information: (All information required) Service Size 1 Ph -1 L.J 3 Ph Size: A # Meters Old Meter# [:]New Service❑Fire Reconnect F ]Flood Reconnect Oservice Reconnect Flunder round Doverhead Underground Laterals LILL] LWJ2r I H Frame Pole Work done on Service? Y N Additl''onal Information.:, PAYMENT DUE WITH APPLICATION 7 s�� MAP OF BAYSIDE TERRACE LOT 19 LOT IS IN 26008130 E 194. 76 ---------------- PROPOSED FENCE (TYP) Vi z _ , — PROPOSED IN GROUND c4- SWIMMING POOL. SEE Of DWG. NO. C-102.00 FOR INEF POOL DETAILS E F N) .... .. 0 C.4 Lij BOA 096014 R°FESSIoNP 4 , O -� 20.0' 16.0' 480 North Bayview Road Ext SOUTHOLD, NY 11971 No. Revisions Date O 0.0' MIN. APPROXIMATE LOCATION OF • PROPOSED EQUIPMENT PAD ISSUED FOR: Pool Site Plan Filing M: DATE: April 15, 2026 DRAWING TITLE: Site Plan 25* RIGHT OF WAY INGRESS AND EGRESS UBER 5776 PAGE 424 DRAWING NO.: S 23033 40 W 217. 57 C� i 01 woo Private Road 21 LAND NOW OR FORMERLY OF NOSKEMCZ 25' RIGHT OF WAY INGRESS AND EGRESS PROJECT NO.: SARA LIBER 5776 PAGE 427 DRAWN BY: DMF SHEET 1 OF 2 NOTES 1 . NO SOIL SURCHARGE PERMITTED WITHIN 4 FEET OF EXCAVATION AT THE SHALLOW END, OR 6 FEET OF EXCAVATION AT THE DEEP END. 2. THIS POOL MEETS THE REQUIREMENTS OF ANSI/APSP/ICC-5 "AMERICAN NATIONAL STANDARD FOR RESIDENTIAL INGROUND SWIMMING POOLS" AND 1998 BOCA CODE-SECTION 421 . DIVING EQUIPMENT IS NOT ALLOWED. - et p i �,�ys 3. SWIMMING POOL SHALL BE COMPLETELY AND CONTINUOUSLY SURROUNDED WITH A BARRIER CONSTRUCTED IAW REQUIREMENTS OF SECTION R328.4.2. 1 THROUGH R328.4.2.9 OF THE NEW YORK STATE RESIDENTIAL r <, CODE (2025) AND IN CONFORMITY WITH ALL SECTIONS OF THE SOUTHOLD TOWN CODE. DWELLING ~ # n k# rr h ' WALL(S) MAY SERVE AS PART OF THE POOL BARRIER AS PER SECTION R328.4.2.8 AND CONDITION (7) ARE MET. OPERABLE WINDOWS IN THE WALL(S) USED AS A BARRIER SHALL HAVE A SELF-LATCHING DEVICE. ACCESS GATES SHALL COMPLY WITH SECTION R328.4.7 OF THE NYS RESIDENTIAL CODE (2025) AND BE SELF-CLOSING, SELF-LATCHING AND BE SECURELY LOCKED WHEN POOL IS NOT IN USE OR SUPERVISED. ALL GATES ARE TO OPEN AWAY FROM THE POOL AREA. 4. DURING CONSTRUCTION THE CONTRACTOR SHALL ERECT A TEMPORARY BARRIER AROUND THE EXCAVATION SUCTION SUCTION IAW THE CODE OF THE TOWN OF SOUTHOLD. 5. POOL MUST BE EQUIPPED WITH AN APPROVED POOL ALARM CAPABLE OF DETECTING ENTRY INTO THE BENCH WATER AND SOUNDING AN AUDIBLE ALARM UPON DETECTION THAT IS AUDIBLE AT POOLSIDE AND INSIDE HEATER THE DWELLING. THE ALARM MUST BE INSTALLED, MAINTAINED AND USED IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. THE ALARM MUST MEET ASTM F2208 "STANDARD SPECIFICATION FOR STEPS POOL ALARMS." THE DEVICE MUST OPERATE INDEPENDENT (NOT ATTACHED TO OR DEPENDENT ON) OF PERSONS. PROPOSED VINYL PUMP CDSWIMMING POOL 6. POOL SUCTION FITTINGS (EXCEPT FOR SURFACE SKIMMERS) MUST BE PROVIDED WITH A COVER THAT CD z CONFORMS TO ANSI/APSP/ICC 16 OR A. MINIMUM 18" X 23" DRAIN GRATE OR A CHANNEL DRAIN SYSTEM. POOL CIRCULATION SYSTEM MUST BE EQUIPPED WITH ATMOSPHERIC VACUUM RELIEF IN THE EVENT THE GRATE COVERS LOCATED WITHIN THE POOL BECOME MISSING OR BROKEN. SUCH VACUUM DUAL MAIN DRAINS WITH STRAINER RELIEF SYSTEMS SHALL CONFORMI WITH ASME Al 12. 19. 17 OR BE A GRAVITY SYSTEM APPROVED BY THE (VGB SAFETY AFT APPROVED DRAINS) TOWN OF SOUTHOLD. POOL SHALL BE PROVIDED WITH A MINIMUM OF 2 SUCTION FITTINGS OF THE ABOVE MENTIONED TYPE. THE SUCTION FITTINGS SHALL BE SEPARATED BY A MINIMUM OF 3' AND MUST BE FILTER PIPED SUCH THAT WATER IS DRAWN THROUGH THEM SIMULTANEOUSLY THROUGH A VACUUM RELIEF-PROTECTED LINE TO THE PUMP (OR PUMPS). VACUUM/PRESSURE CLEANING FITTINGS SHALL BE RETURN T RETURN IN AN ACCESSIBLE POSITION, MINIMUM OF 6" AND NO GREATER THAN 12" BELOW THE MINIMUM OPERATIONAL WATER LEVEL OR BE AN ATTACHMENT TO THE SKIMMER/SKIMMERS. A REQUIRED POOL ATMOSPHERIC VACUUM RELIEF SYSTEM SHALL BE INSTALLED AS PER NYS RESIDENTIAL CODE R328 32.0' (2025) AND IN ACCORDANCE WITH TOWN CODE. 7. ALL ELECTRICAL WORK SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 70 (NEC) PRINCIPALLY ARTICLE POOL PLAN 680 AND THE NYS RESIDENTIAL CODE SECTIONS 4201 THROUGH 4209. ALL ELECTRICAL DEVICES MUST SCALE: 1 "=5' BE APPROVED BY UNDERWRITERS LABORATORIES AND BE PROTECTED BY A GROUND FAULT CURRENT INTERRUPTER (GFCI) CURRENT CARRYING ELECTRICAL CONDUCTORS EXCEPT FOR THOSE PROVIDING POWER OF NEW TO POOL LIGHTING, AND POOL EQUIPMENT SHALL MEET THE SEPARATION REQUIREMENTS OF E4203. ALL P�� a\E FE IT yo METAL ENCLOSURES, FENCES OR RAILINGS NEAR OR ADJACENT TO THE SWIMMING POOL THAT MAY *c, P BECOME ELECTRICALLY CHARGED DUE TO CONTACT WITH AN ELECTRICAL CIRCUIT SHALL BE EFFECTIVELY 32.0 GROUNDED. _ 8. WATER SOURCE FILLING THE POOL SHALL BE EQUIPPED WITH A BACKFLOW PROTECTION DEVICE IAW NYS m � PLUMBING CODE 608. o �96014���t�,'�a 9. ALL PIPING IS DIAGRAMMATIC UNLESS OTHERWISE STATED. co Ess10 10. WALKS IF PROVIDED SHALL BE NONSLIP AND SLOPE AWAY FROM POOL EDGE. In 11 . A MEANS OF EGRESS FOR DEEP AND SHALLOW ENDS MUST BE PROVIDED IAW ANSI/APSP/ICC-5 SECTION 6. 12. CONTRACTOR TO PLACE THE POOL IAW TOWN OF SOUTHOLD CODE SETBACKS. 11 .0' .5' 7.5' 4.0' 13. ALL DRAINAGE FROM THE POOL SHALL BE MAINTAINED ON THE SUBJECT PROPERTY. POOL PROFILE 14. THE DESIGN IS BASED ON A DRAINAGE SOIL WITH < 10% SILT. GROUND WATER SHALL NOT EXIST WITHIN SCALE: 1 "=5' 480 North Bayview Road Ext THE EXCAVATION. IF GROUND WATER EXISTS WITHIN 6'-0" FROM GRADE, DEWATERING FACILITIES WILL BE SOUTHOLD, NY 11971 REQUIRED. 15. ALL GAS AND OIL HEATERS (IF I1\�STALLED) FOR THE INGROUND SWIMMING POOL SHALL BE NATIONAL No. Revisions Date APPLIANCE ENERGY CONSERVATIOIN ACT (NAECA) COMPLIANT. POOL HEATERS SHALL BE TESTED IAW ANSI Z21 .56 AND SHALL BE INSTALLED IAW MANUFACTURERS SPECIFICATIONS. OIL-FIRED POOL HEATERS SHALL BE TESTED IAW UL726. POOL HEATERS SHALL BE LOCATED OR GUARDED TO PROTECT AGAINST ACCIDENTAL CONTACT OF HOT SUJRFACES BY PERSONS. POOL HEATERS SHALL BE PROVIDED WITH TEMPERATURE AND PRESSURE-RELIEF VALVES. FOR HEATERS NOT PROVIDED WITH AN INTEGRAL BYPASS SYSTEM, A BYPASS LINE SHALL BE INSTALLED FROM INLET TO OUTLET TO ADJUST WATER FLOW THROUGH THE HEATER. POOL HEATERS SHALL BE PROVIDED WITH THE FOLLOWING ENERGY CONSERVATION MEASURES: 15. 1 . AT LEAST ONE THERMOSTAT SHALL BE PROVIDED FOR EACH HEATING SYSTEM. 15.2. ALL POOL HEATERS SHALL BE EQUIPPED WITH AN ON-OFF SWITCH MOUNTED FOR EASY ACCESS TO ALLOW SHUTTING OFF THE OPERATION OF THE HEATER WITHOUT ADJUSTING THE THERMOSTAT SETTING AND TO ALLOW RESTARTING WITHOUT RESETTING THE PILOT LIGHT. 15.3. HEATED SWIMMING POOLS SHALL BE EQUIPPED WITH A POOL COVER (EXEMPTED FROM THIS COPING AND WALKWAY REQUIREMENT ARE OUTDOOR POOLS DERIVING 60% OF THE ENERGY FOR HEATING FROM RENEWABLE BY OTHERS RADE ( ) ISSUED FOR: SOURCES AS COMPUTED OVEIR AN OPERATING SEASON). FILTER 15.4. TIME CLOCKS SHALL BE INSTALLED SO THE PUMP CAN BE SET TO RUN DURING OFF-PEAK 2" TO WASTE PUMP HEATER Pool Site Plan Filing ELECTRICAL DEMAND PERIODS AND CAN BE SET TO RUN THE MINIMUM TIME NECESSARY TO MAINTAIN WATER LINE THE POOL WATER IN A CLEAN AND SANITARY CONDITION IAW APPLICABLE SANITARY CODE OF NEW - - YORK STATE. ' AND APPURTENANCES ARE DEFINED °. 2-2„ -III:-1 I t^ DATE: 16. THIS DRAWING IS FOR STRUCTURAL SHELL ONLY. ALL ACCESSORIES AUTO BY S. 10" � (-=I � I=� SKIMMER 17. BACKFILL RWITH CLEAN EARTH, FREE OF ROOTS AND DEBRIS. DO NOT ALLOW THE HEIGHT OF BACKFILL TO >1III:=I PENTAIR AUTOMATION, April 15, 2026 EXCEED THE HEIGHT OF THE WATER IN THE POOL BY MORE THAN 8", OR THE WATER TO EXCEED LED LIGHTS, FILTRATION, Pool _ 140k ELECTRIC HEATER BACKFILL BY MORE THAN 8". 3,500 PSI POURED a III:T 18. PLACE CONCRETE ON SANDY TO LOAM SOIL. REMOVE ANY CLAY DEPOSIT AND REPLACE W/ COMPACTED CONCRETE O I (- BACK TO DRAWING TITLE: CLEAN 19. THERE BACKFILL.MAIN DRAIN IN THIS POOL. SUCTION FOR POOL WATER CIRCULATION IS PROVIDED BY THE 3/8" REBAR (TYP) POOL a a ° _ S NO (�I SKIMMERS ONLY. THIS MEETS REQUIREMENTS OF THE NYS RESIDENTIAL CODE VINYL LINER SECTION R328.5. 1 FOR ( I= OPTIONAL DUAL MAIN Notes and Details ENTRAPMENT PROTECTION. 2" TO 4" SAND a I DRAIN WITH HYDROSTATIC 20. THE POOL WAS DESIGNED IAW THE FOLLOWING: > ° VALVE AND COLLECTOR TUBE IN GRAVEL BASE 20. 1 . THE NEW YORK STATE RESIDENTIAL CODE - SECTION R328 (2025) PIPING SCHEMATIC 20.2. THE NEW YORK STATE ENERGY CONSERVATION CONSTRUCTION CODE - SECTION R404.9 (2025) 20.3. THE NEW YORK STATE FUEL GAS CODE (2025) 20.4. THE NEW YORK STATE SANITARY CODE �!� ( �`�� ��� -� (-� UNIDISTURBED EARTH DRAWING NO.: 20.5. ANSI/APSP/ICC-5 STANDARD FOR RESIDENTIAL IN-GROUND SWIMMING POOLS VERTICAL 3/8" 20.6. BOCA CODE - SECTION 421 REBAR T 3' O.C. (NOT SHOWN) WALL DETAIL 20.7. CODE OF THE TOWN OF SOUTHOLD SCALE: N.T.S. C� l 02000 21 . ALL BACKWASH TO BE SELF-CONITAINED ON-SITE. PROJECT NO.: SARA DRAWN BY: DMF SHEET 2 OF 2