Loading...
HomeMy WebLinkAbout52930-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52930 Date: 04/30/2026 Permission is hereby granted to: David Scheer 314 St Johns PI Apt 4F Brooklyn, NY 11238 To: construct an accessory in-ground swimming pool as applied for. Premises Located at: 1250 Bayview Ave, Greenport, NY 11944 SCTM# 52.-5-49 Pursuant to application dated 04/15/2026 and approved by the Building Inspector. To expire on 04/29/2028. Contractors: Required Inspections:. Fees: SWIMMING POOLS-IN-GROUND WITH FENCE ENCLOSURE $300.00 CO Swimming Pool $100.00 Total $400.00 w", Building Inspector r)rae TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax(631) 765-9502 httpi://vw . out:ll2lcit(LNkti O Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only 1 C PERMIT NO. Building lnspecton � APR I Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: fU OWNER(S)OF PROPERTY: Name:--, SCTM#1000- �2 a 5 9 Project Address: f S� �� A) y/ ,7 Phone#: �o{ _ 9 3r .2 Email: 66q f-e-r-c� 73 rv, ,Cure► Mailing Address: /-:1 CONTACT PERSON: Name: %0-K7 Mailing Address: �. �o x �� � uer 1V Y //73!s- Phone#: � 3� "7�y���o�vS Email: Un �lr7e, ncr DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: -- Gv)-5 Ltd. Mailing Address: •'p.Cj, -3 X Q (. L"0 SLAX- 3s- Phone#: &-31 7341-,;;66 S- Email: c 714LXcc)U')7+vY')11- oe— n Q DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: XOther $ �Uno< C)G Will the lot be re-graded? )'es El No Will excess fill be removed from premises? ❑Yes, lo 1 PROPERTY INFORMATION Existing use of property: ���9nc� Intende se of roperty:"I Z5r' es F ' ° Zone or use district in which premises is situated:: Are there any covenants and restrictions with respect to this property? ❑ rYes No IF YES, PROVIDE A COPY. O(Che k Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(pri name): 7 r XjAuthorized Agent El owner Signature of Applicant: Date: CONNIE D.BUNCH Notary Public,State of New York STATE OF NEW YOR No.01BU6185050 SS: Qualified In Suffolk County . COUNTY OF ) CoMmission Expires April 14,2 0 pj being duly sworn, deposes and says that(s)he is the applicant (Name o individual signing contract)above named, (S)he is the tr— (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. 1Sworn before me this F 64�ay of t 2 i " " ►'/►ti"� Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) residing at V`- Av-9— t �do hereby authorize 1,2bi 4� Laj , to apply on my behalf to the Town of Southold Building Department for approval as described herein. k, 4 C --YhJ2,P Owners Signature Date Print Owner's Name 2 f �t AP '0 ED AS NOTED FEE BY NOTIFY BUILDING DEPARTMENT AT 631-765-1802 6AM TO 4PM FOR THE RETAIN STORM WATER RUNOFF FOLLOWING INSPECTIONS: PURSUANT TO CHAPTER 236 1. FOUNDATION-TWO REQUIRED OF THE TOWN CODE. FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS INSPEC`nOli REQUIRED NEW F STATE &TOWtJ ("'ODE''S AS EQ IFiED AlqD C( NDiTI( NS OF DT0 N SN,S S LFC�ff°���i �f�I'��Ih,� FTOMG ITLUS,�� ��,' IE� "IIE OLDHPC "IMMEDIATELY" ENCLOSE POOL TO CODE UPON COMPLET0NI BEFORE VA TER" OCCUPANCY OR VE IS UNLAWFUL. WITHOUT OF ifMX JAMES COMPLIES WITH; —— — ———- — — DEERKOSKi r---- 2025 CODE SECTION 303.1-303A SWIMMING POOLS,SPAS,AND HOT TUBS P.E. SECTION R328 OF THE RESIDENTIAL CODE OF NEW YORK - SECTION 3109 OF THE BUILDING CODE OF NEW YORK (f'� SECTION 303.2 RESIDENTIAL POOLSAND PERMANENT RESIDENTIAL SPAS \ Y- Y SECTION 304.19 POOLS AND SPA GATES,BARRIERS - I SECTION 303.4 ENTRAPMENT PROTECTION j SECTION ALARMS SECTION E420 E4201-E4312 ELECTRICAL CONNECTIONS FOR POOLS n Memack Newtat D95. POOL NOTES: Y n m R 1 1. POOL AND PROPERTY TO CONFORM TO CURRENT STATE AND LOCAL CODE,ENERGY CONSERVATION REVISIONS (R403.10)AND ELECTRICAL CODES. N° �scaun°u 2. POOL SHALL CONFORM TO ANSIINSPI STANDARDS R326. I 3. SECTION R328.6 POOL ALARMS TO BE INSTALLED AS REQUIRED BY CODE. t 4. INSTALL TEMPORARY PERIMETER BARRIERS AROUND CONSTRUCTION AREA DURING —3 CONSTRUCTION.FINAL FENCING BARRIER PER R328.4.2.1-R328.4.2.9.ALL GATE ACCESS TO BE 1 SELF-CLOSING AND SELF-LATCNINGjLOCKING PER CODE. - 1 5, POOL AND HOT TUBS TO COMPLY WITH R403.10(HEATERS,TIMERS,AND COVER). 6. SEE DETAILS FOR REBAR AND REQUIRED SUPPORT. ' 7. 3500 PSI POURED CONCRETE WALLS,MIN.40'. i J ` e. THE PNEUMATICALLY APPLIED CONCRETE(GUNITE)SHALL BE 4,000 PSI @ 28 DAYS,IF APPLICABLE. — --— — — 4. FINE WASHED SAND BASE WITH PORTLAND MIX AT BOTTOM. x + 10. SOIL CONDITIONS AND SITE MANAGEMENT TO BE RESPONSIBILLTY OF CONTRACTOR.PROVIDE SOIL COMP^M` TEST IN POOR SOIL CONDITIONS. IT. SEE SITE PLAN(BY CONTRACTOR)FOR POOL LOCATION.SETBACKS,VARIANCES,AND OTHER STATES AND LOCAL REQUIREMENTS TO BE VERIFIED PRIOR TO CONSTRUCTION. 12. DRAIN COVERS TO MEET CODE REQUIREMENTS(VIF). 13. POOL PATIO SURFACE TO SLOPE AWAY FROM POOL n":1'-0"AND AWAY FROM HOUSE IF CONNECTED. PROVIDE ADDITIONAL DRAINAGE IF NECESSARY. 3 b ADDRESS: 14. INSTALL CLEAN BACKFILL,FREE OF CLAY AND ORGANIC MATTER.COMPACT SOIL AS REQUIRED PROPOSED POOL PRIOR TO PATIO INSTALLATION. Iua BAtvIEw AYENCE SS. SUCTION OUTLETS PER ANSUAPSP-7.VERIFY IN FIELD PRIOR TO CONSTRUCTION. souxxotn.NY I19'tt 16. SURCHARGE NOT PERMITTED WITHIN f FROM SHALLOW AND 6'FROM DEEP ENDS. 17. POOL EQUIPMENT LOCATION TO BE DETERMINED IN FIELD(MAINTAIN MINIMUM SETBACKS AS / REQUIRED). va I8. DIVING BOARD TO BE DETERMINED BY INSTALLER AND OWNER 19. SALTWATER GENERATOR SYSTEMS MUST BE INSTALLED BY A LICENSED PROFESSIONAL TO COMPLY i j WITH NATIONAL EUIKIRICAL CODE(NEC)STANDARDS. DATE: {({ by ".•t.. s .A^,bx,ecr.H,rr.,tl wn5xta5 j 28t_S I msm, �: t � DRAWti BY: C.O. LLL O 5s ® cRA nEaiER xvx�eoarvE .r.. SCALE: INTS. DRAWING TITLE: F NEtq Y POOL PLAN art:xn_awwwx auu _ DISTURBED FAR eu,¢ £ S}{EET NO. MA PIPING SCHETIC TYP.PANEL STIFFENER 50 a - TYP.WALL SECTION AT'A'FRAME JAMES F-7N,OTIES: DEERKOSKI P.E. DINING BOARD TO CONFORM WITH ANSUAPSPIICC-5 SEC 6 NO SOIL DISCHARGE PERMITTED WITHIN 4 FEET OF EXCAVATION O 3. POOL MUST BE SURROUNDED BY A CONTINUOUS BARRIER CONSTRUCTED LAW REQ.OF SEC 328.4.2.1-R328.4.2.9 OF THE NYS RESIDENTIAL CODE(2025)AND ALL SECTIONS OF THE SOUTHOLD CODE a 4. WALLS MAY SERVE AS PART OF THE POOL BARRIER AS PER SEC 304.19 AND ALL WINDOWS HAVE A SELF LATCHING DEVICE 5. ACCESS GATES SHALL COMPLY WITH SEC R328.5.2 OF THE NYS RESIDENTIAL CODE(2025)AND BE SELF CLOSING,SELF LATCHING AND BE SECURELY LOCKED WHEN POOL IS NOT IN USE OR SUPERVISED. ALL GATES ARE TO OPEN AWAY FROM THE POOL AREA. 6. DURING CONSTRUCTION THE CONTRACTOR SHALL ERECT A TEMPORARY BARRIER AROUND THE EXCAVATION LAW CODE OF THE TOWN OF SOUTHOLD- _-m.._,..,—it:!=sz 7. POOL MUST BE EQUIPED WITH AN APPROVED POOL ALARM CAPABLE OF DETECTING ENTRY INTO THE WATER AND SOUNDING AN AUDIBLE ALARM WHEN DETECTED THAT IS AUDIBLE AT THE POOLSIDE AND INSIDE THE DWELLING.THE ALARM MUST BE INSTALLED,MAINTAINED AND USED IN ACCORDANCE WITH TEH MAUFACTURERS INSTRUCTIONS.THE ALARM MUST MEET ASTM F2208"STANDARD SPECIFICATION FOR POOL ALARMS",THE DEVICE MUST OPERATE INDEPENDENT(NOT ATTACHED TO OR DEPENDENT ON)OF PERSONS. .z=.v�s;ons 8. POOL SUCTION FITTINGS(EXCEPT FOR SURFACE SKIIMERS)MUST BE PROVIDED WITH A COVER THAT CONFORMS TO ASMEIANSI Al 12.19.8M OR A MINIMUM 18-X23"DRAIN GRATE OR A CHANNEL DRAM SYSTEM,POOL CIRCULATION SYSTEM MUST BE EQUIPIED WITH ATMOSPHERIC VACUUM RELIEF.SUCH VACUUM RELIEF SYSTEMS SHALL CONFORM WITH ASME Al 12.19.17 OR BE A GRAVITY SYSTEM APPROVED BY THE TOWN OF SOUTHOLD.POOL SALL BE PROVIDED WITH A MINIMUM OF 2 SUCTION FITTINGS OF THE ABOVE MENTIONED TYPE.THE SUCTION FITTINGS SHALL BE SEPARATED BY A MINIMUM OF S AND MUST BE PIPED SUCH THAT WATER IS DRAWN THROUGH THEM SIMULTANEOUSLY THROUGH A VACUUM RELIEF-PROTECTED LINE TO THE PUMP(OR PUMPS).VACUUMIPRESSURE CLEANING FITTINGS SHALL BE N ACCESSIBLE POSITION.MINIMUM OF 6"AND NO GREATER THAN 12`BELOW THE MINIMUM OPERATIONAL WATER LEVEL OR BE AN ATTACHMENT TO THE SKIv1MER(SKIMMERS. A REQUIRED POOL ATMOSPHERIC VACUUM RELIEF SYSTEM SHALL BE INSTALLED AS PER NYS RESIDENTIAL COIF R326(2025)AND IN ACCORDANCE TO TOW CODE 9. ALL ELECTRICAL WORK SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 70(NEC),PRINCIPALLY ARTICLE 680 AND THE NYS RESIDENTIAL CODE SECTION 4102 THROUGH 4106.ALL ELECTRICAL DEVICES MUST BE APPROVED BY UNDERWRITERS LABORATORIES AND BE PROTECTED BY A GOUND FAULT CURRENT INTERRUPER(GFCIL CURRENT CARRYING ELECTRICAL CONDUCTORS EXCEPT FOR THOSE PROVIDING POWER TO POOL LIGHTING AND POOL EQUIPMENT SHALL MEET THE SEPARATION REQUIREMENTS OF TABLE E4203.5, ALL METAL ENCLOSURES.FENCES OR RAILINGS NEAR OR ADJACENT TO THE SWIMMING POOL THAT MAY BECOME ELECTRICALLY CHARGED DUE TO CONTACT WITH AN ELECTRICAL CIRCUIT SHALL BE EFFECTIVELY GROUNDED, 10. WATER SOURCE FILLING THE POOL SMALL BE EQUIPPPED WITH A BACKFLOW PROTECTION DEVICE LAW NYS PLUMBING CODE 608. w+tea : 11. ALL PIPING IS DIAGRAMMATIC UNLESS OTHERWISE STATED. 12. WALKS,IF PROVIDED SHALL BE NONSLIP AND SLOPE AWAY FROM THE POOL EDGE. 13. A MEANS OF EGRESS FROM DEEP AND SHALLOW ENDS MUST BE PROVIDED LAW ANSI/NSPI5 SECTION 6. 14. CONTRACTOR TO PLACE THE POOL LAW TOWN OF SOUTHOLD CODE SETBACKS. 15. ALL DRAINAGE FROM THE POOL SHALL BE MAINTAINED ON THE SUBJECT PROPERTY. i.aDRFSS.- 16 THE DESIGN IS BASED ON A DRAINAGE SOIL WITH<10%SILT.GROUND WATER SHALL NOT EXIST WITHIN THE EXCAVATION.IF GROUND WATER EXISTS WITHIN 6V FROM GRADE,DEWATERING FACILITIES WILL BE REQUIRED. Paorosen POOL 17 ALL GAS AND OIL WATER HEATERS(IF INSTALLED)FOR THE IN-GROUND SWIMMING POOL SHALL BE NATIONAL APPLIANCE ENERGY CONSERVATION ACT(NAECA)COMPLIANT.POOL HEATERS SHALL TESTED JAW ANSI Z2156 AND SHALL BE INSTALLED JAW MANUFACTURERS SPECIFICATIONS-03L FIRED POOL HEATERS SHALL BE TESTED LAW UL726.POOL HEATERS SHALL BE LOCATED OR GUARDED TO 1-P,yvvw PROTECT AGAINST ACCIDENTAL CONTACT OF HOT SURFACES BY PERSONS.POOL HEATERS SHALL BE PROVIDED WITH TEMPERATURE AND PRESSURE-RELIEF VALVES.A BYPASS LINE SHALL BE INSTALLED soc,TxeLa.av:is�� FROM THE INLET TO OUTLET TO ADJUST WATER FLOW THROUGH THE HATER.POOL HEATERS SHALL BE PROVIDED WITH THE FOLLOWING ENERGY CONSERVATION MEASURES: 17.1 ALL POOL HEATERS SHALL BE EQUIPPED WITH AN ON-OFF SWITCH MOUNTED FOR EASY ACCESS TO ALLOW SHUTTING OFF THE OPERATION OF THE HEATER WITHOUT ADJUSTING THE THERMOSTAT SETTING AND TO ALLOW RESTARTING WITHOUT RELIGHTING THE PILOT LIGHT. AT LEAST ONE THERMOSTAL MUST BE PROVIDED FOR EACH HEATING SYSTEM.HEATED SWIMMING POOLS SHALL BE EQUIPTED WITH A POOL COVER(exempt FROM THIS ARE OUTDOOR POOLD)DERIVING 20%OF THE ENERGY FOR HEATING THE POOL FROM RENEWABLE SOURCES OVER AN OPERATING SEASON. 172 TIME CLOCKS SHALL BE INSTALLED SO THE PUMP CAN BE SETTO RUN DURING OFF-PEAK ELECTRICAL DEMAND PERIODS,AND CAN BESET TO RUN THE MINIMUM TIME NECESSARY TO MAINTAIN THE POOL WATER IN A CLEAN AND SANATORY CONDITION LAW APPLCIABUE SANATORY CODE OF NEW YORK STATE. aATE: __zs 18 BAC(FILL WILL BE DONE WITH CLEAN EARTH FREE OF ROOTS AND DEBRIS. BACKFILL HEIGHT AND WATER LEVEL TO BE WITHIN 8"OF EACH OTHER. PLACE CONCRETE ON SANDY LOAM SOIL. CLAY TO BE 0-1—BY c.o. REMOVED AND REPLACED WITH SANDY LOAM. 19 DRAIN REQUIREMENT-SINGLE OR MULTIPLE PUMP CIRCULATION SYSTEMS MUST HAVE A MINIMUM OF TWO SUCTION OUTLETS OF AN APPROVED TYPE,SEPARATED BY A =c,+Lt ns no=en HORIZONTAL OR VERTICAL DISTANCE OF AT LEAST 3 FEET, 20 THE POOL WAS DESIGNED REFERENCES AS THE FOLLOWING: F NF H, oaaartuc n:ze: 20.1 THE RESIDENTIAL BUILDING CODE OF NEW YORK STATE(2025)SEC R328 POOL 9 202 THE ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE(2025)SEC R403-10 �` , ;ERxO' fi * �+"'-_ �' � �� NOTES 20.3 THE FUEL GAS CODE OF NEW YORK STATE(2025) A ' z m �� 20.4 THE NEW YORK STATE SANATORY CODE. 20.5 ANSVAPSP11CG5 STANDARD FOR RESIDENTIAL IN-GROUND SWIMMING POOLS. O V25 � ^ 20.6 BOCA CODE SECTION 421. E A 20.7 COMPLIES W[TH CODE OF THE TOWN OF SOUTHOLD Gr Re_ OI oZ1� SURVEY OF LOTS 107, 108, 109 & 110 MAP SHOWING SUBDIVISION OF PROPERTY KNOW AS SUMMER HAVEN BELONGING TO WILLIAM G. HERZ FILE No. 1133 FILED JULY 5, 1933 R " SITUATED AT COL,�l� � -T g %, SOUTHOLD &A TOWN OF SOUTHOLD par s a SUFFOLK COUNTY, NEW YORK S.C. TAX No. 1000-52-05-49 110. Q e Y SCALE 1"=30' D O a ; t �` �,. o� e, F g t�."" e JULY 17, 2001 A DECEMBER 27, 2001 REVISED AS PER HEALTH DEPARTMENT LETTER FEBRUARY 15. 2002 ADDED SANITARY SYSTEM FOR SURROUNDING PROPERTIES NOVEMBER 21, 2002 RELOCATED PROPOSED HOUSE. WELL& SEPTIC SYSTEM k OCTOBER 22, 2003 REVISED WELL LOCATION ON VASILAIOS PROPERTY it t tf FEBRUARY 10. 2004 REVISED PROPOSED WELL & SEPTIC SYSTEM t n JANUARY 25, 2005 REVISED TO SHOW PUBLIC WATER a do �` r1 rl JANUARY 20. 2SO06 REVISED PROPOSED HOUSE& GARAGE r, a AUGUST 2. 2006 FOUNDATION LOCATION NOVEMBER 20. 2007 FINAL SURVEY ,moo. AREA = 15,000.00 sq. ft. 0.344 ac. soy # CERTIFIED TO: WLODANNAZ LOCH W1SOR r Ord ayllp�'L S.C.D.H.S. REFERENCE No. R10-01-0216 p% cC cYj - wA� r �� F ITION COUNTYDEPARTM TO THIS SURVEY�vwunoN OF 1 CtINS7 HEALTH C£S SEC 7zoe of THE New YONK STATE t �s t PPROVA,f.C}F r?CICTEO muCARON LAW. -•_ f £` EJ Slr�:.i. rt??!J., WD1{.`P COPIES OF THIS SURVEY AiAP NOT BEAR Date U�� {=ti .".Tj Vs RESfDFjtCE THE IAf+D SEAL StR's INXED SEAL OR SI TOB E A SEX TRUE A1.NOT BE CONSIDERED fia y �{S NO. TO BE A VALID TRUE COPY. t r?t`-• L�1 � 6"�60 ' ' drip—1-nd CERAF3C0.? "S!NDiCATm HEREON SH+Sk RUN t F d 1- 4' `RsP d ti Jd eLtpply.fat>lttles at!:U k? ONBY TD THE PERSON F wHOM THE suM ` .h6 �P `sReit1 Aai'@ t�et1 IS PREPARED.AND ON HIS BEKA F TO Tiff N`S,y set"(aate+;,t,' ar O;B 44T j <d MAXI t `r &'mid tbtxu}b LEND COMPAW.IONGoVERNMEWALHE EONN AND j/ frr�t J SEDRt.�Otr1S, LENDING wsTncnDH usrm HEREON.Aran THEP.; fo �--/ ,, `� a ✓v .��'\. TTUUTi CE.RTIIFICATIONiS IGNEES OF THE Ho TR ITR M;FE ABLE- p OWelter J. USfice t7f W Wit'F.E., aSt!'K'dfE�l'M3I13j1¢tT18}tt THE EXISTENCE OF RIGHTS OF WAY AN EASEMENTS OF RECORD, IF - F z ANY,Y. N07 SHOWN ARE NOT GUARANTEED. PREPARED IN ACCORDANCE WITH THE I.AN!MUM BY T14EP.LI FOR �sLlRME AS EStAiOPTEm Lathan Taft Corwin 111 BY THE L!USE AND APPRO.EO AND AOOPTm FOR SUCH USE BY THE NEW YOR1C STATE WtO TITLE ASSOCIATION. Land Surveyor i Title Surveys —Subdivisions — Site Plans — Construction Layout PHnNF (630727-2090 Fax (631)727-1727 JAMES COMPLIES WITH: - - - - - - - -,- - - - - - - - - - - - - - - - - - - - - - DE ERKO SKI 2025 CODE SECTION 303.1-303.4 SWIMMING POOLS,SPAS,AND HOT TUBS l �J RETURN 5v � P.E. SECTION R328 OF THE RESIDENTIAL CODE OF NEW YORK SECTION 3109 OF THE BUILDING CODE OF NEW YORK pp D n O SECTION 303.2 RESIDENTIAL POOLS AND PERMANENT RESIDENTIAL SPAS H�f' O 2V,2b SECTION 304.19 POOLS AND SPA GATES,BARRIERS SECTION 303.4 ENTRAPMENT PROTECTION SECTION 303.3 ALARMS SECTION E4201-E4312 ELECTRICAL CONNECTIONS FOR POOLS HEATER Mattituck,New York 11952 POOL NOTES: Q Eami1:j=csdeelkoski@yohoo.com PUMP MAW DRAIN 18'- 1. POOL AND PROPERTY TO CONFORM TO CURRENT STATE AND LOCAL CODE,ENERGY CONSERVATION ll" --- -- -- STAIRS (MIN.3'APARI) (R403.10)AND ELECTRICAL CODES. NO. DESCRIPTION DATE REVISIONS 2. POOL SHALL CONFORM TO ANSI/NSPI STANDARDS R326. FILTER 3. SECTION R328.6 POOL ALARMS TO BE INSTALLED AS REQUIRED BY CODE. 4. INSTALL TEMPORARY PERIMETER BARRIERS AROUND CONSTRUCTION AREA DURING CONSTRUCTION.FINAL FENCING BARRIER PER R328.4.2.1-R328A.2.9.ALL GATE ACCESS TO BE SELF-CLOSING AND SELF-LATCHING/LOCKING PER CODE. 5. POOL AND HOT TUBS TO COMPLY WITH R403.10(HEATERS,TIMERS,AND COVER). 6. SEE DETAILS FOR REBAR AND REQUIRED SUPPORT. 7. 3500 PSI POURED CONCRETE WALLS,MIN.40". 8. THE PNEUMATICALLY APPLIED CONCRETE(GUNITE)SHALL BE 4,000 PSI @ 28 DAYS,IF APPLICABLE. I 36 " 9. FINE WASHED SAND BASE WITH PORTLAND MD(AT BOTTOM. L_ - SUCTION - - - - - - - - - -SUCRON 10. SOIL CONDITIONS AND SITE MANAGEMENT TO BE RESPONSIBILITY OF CONTRACTOR.PROVIDE SOIL - - - - - - - - - - - - - - - - - - J COMPANY: TEST IN POOR SOIL CONDITIONS. 11. SEE SITE PLAN(BY CONTRACTOR)FOR POOL LOCATION.SETBACKS,VARIANCES,AND OTHER STATES AND LOCAL REQUIREMENTS TO BE VERIFIED PRIOR TO CONSTRUCTION. 36-0" 12. DRAIN COVERS TO MEET CODE REQUIREMENTS(VIF). 13. POOL PATIO SURFACE TO SLOPE AWAY FROM POOL 4":V-0"AND AWAY FROM HOUSE IF CONNECTED. PROVIDE ADDITIONAL DRAINAGE IF NECESSARY. Y-6" ADDRESS: 14. INSTALL CLEAN BACKFILL,FREE OF CLAY AND ORGANIC MATTER.COMPACT SOIL AS REQUIRED PROPOSED Pool PRIOR TO PATIO INSTALLATION. 1250 15. SUCTION OUTLETS PER ANSI/APSP-7.VERIFY IN FIELD PRIOR TO CONSTRUCTION. SOUTHOLDOLD,w AVENUE OU NY 11971 16. SURCHARGE NOT PERMITTED WITHIN N FROM SHALLOW AND 6 FROM DEEP ENDS. 17. POOL EQUIPMENT LOCATION TO BE DETERMINED IN FIELD(MAINTAIN MINIMUM SETBACKS AS REQUIRED). o 0 0 18. DIVING BOARD TO BE DETERMINED BY INSTALLER AND OWNER. 19. SALTWATER GENERATOR SYSTEMS MUST BE INSTALLED BY A LICENSED PROFESSIONAL TO COMPLY 20 MIL.VINYL LINER 0 WITH NATIONAL ELECTRICAL CODE(NEC)STANDARDS. ADJUSTABLE STEEL WALL PANEL 1.6xi.SX44.11 GA.GALV o ANGLE DATE: 4/28/26 0. 3/e'-16XI'BOLT,NUT,(2)WASHERS 1'1 WELDS ON SIDE OF PANEL DRAWN BY: C.D. WEIDEO TOP&BOl'fOM AS SHOWN AND COVDL p OVER WEID.S WITH 6'x 9'DRYWELL 2x2X18 DRIVE STAKE ALUMINUM mAnNG HEATER7�7 SCALE: N.T.S. FILTER MOUND W13 CU. O DRAWING TITLE: PUMP FT.CONCRETE UTO SIGMMER O 1.5 14 GA. GA GLE 2•THICK SAND BOTTOM E Ewy POOL t C C DEEP o PENTAIR AUTOMATION,LED - - LIGHTS,FILTRATION,140k POOL 'I�-III-II I 111=II Ih I III-II I III-II-III=II III' .� -f CJ �� ELECTRIC HEATER IIIII ICI I I II I II I II If=II I II; I�1 I- * U BACK TO _ _ _ _ 18'LONG STEEL REINFORCING ROD POOL III I ' II II III " III II I-II INTO UNDISTURBED EARTH C�q-•` '/' ICI NDISTURBED EARTH III _I�II� THROUGH HOLES IN BOTTOM OF SHEET NO. OPTIONAL DUAL MAIN DRAIN -II II -III PANEL Z I I I WTTH HYDROSTATIC VALVE AND ,���u�,1 (IO •,s-,/ - �' PIPING SCHEMATIC COLLECTOR TUBE IN GRAVEL BASE III=' TYP.PANELSTIFFENER N.T.S. �o`A TYP.WALL SECTION AT'A'FRAME �O�SSIO P� A 1 JAMES NOTES: DEERKOSKI 1. DIVING BOARD TO CONFORM WITH ANSVAPSP/ICG5 SEC 6 P.E. 2_ NO SOIL DISCHARGE PERMITTED WITHIN 4 FEET OF EXCAVATION o 3_ POOL MUST BE SURROUNDED BY A CONTINUOUS BARRIER CONSTRUCTED IAW REQ.OF SEC 328.4.2.1-R328A.2.9 OF THE NYS RESIDENTIAL CODE(2025)AND ALL SECTIONS OF THE SOUTHOLD CODE 4. WALLS MAY SERVE AS PART OF THE POOL BARRIER AS PER SEC 304.19 AND ALL WINDOWS HAVE A SELF LATCHING DEVICE 5. ACCESS GATES SHALL COMPLY WITH SEC R328.52 OF THE NYS RESIDENTIAL CODE(2025)AND BE SELF CLOSING, SELF LATCHING AND BE SECURELY LOCKED WHEN POOL IS NOT IN USE OR SUPERVISED. ` ALL GATES ARE TO OPEN AWAY FROM THE POOL AREA. 6_ DURING CONSTRUCTION THE CONTRACTOR SHALL ERECT A TEMPORARY BARRIER AROUND THE EXCAVATION IAW CODE OF THE TOWN OF SOUTHOLD_ MatHmok,New York 11952 7. POOL MUST BE EQUIPED WITH AN APPROVED POOL ALARM CAPABLE OF DETECTING ENTRY INTO THE WATER AND SOUNDING AN AUDIBLE ALARM WHEN DETECTED THAT IS AUDIBLE AT THE POOLSIDE AND Email:jamcsdmlostiQyahoo.com INSIDE THE DWELLING.THE ALARM MUST BE INSTALLED, MAINTAINED AND USED IN ACCORDANCE WITH TEH MAUFACTURERS INSTRUCTIONS.THE ALARM MUST MEET ASTM F2208"STANDARD SPECIFICATION FOR POOL ALARMS".THE DEVICE MUST OPERATE INDEPENDENT(NOT ATTACHED TO OR DEPENDENT ON)OF PERSONS. REVISIONS NO. DESCRIPTION DATE 8. POOL SUCTION FITTINGS(EXCEPT FOR SURFACE SKIIMERS)MUST BE PROVIDED WITH A COVER THAT CONFORMS TO ASME/ANSI Al12.19.8M OR A MINIMUM 18"X23"DRAIN GRATE OR A CHANNEL DRAIN SYSTEM.POOL CIRCULATION SYSTEM MUST BE EQUIPTED WITH ATMOSPHERIC VACUUM RELIEF.SUCH VACUUM RELIEF SYSTEMS SHALL CONFORM WITH ASME Al12.19.17 OR BE A GRAVITY SYSTEM APPROVED BY THE TOWN OF SOUTHOLD_POOL SALL BE PROVIDED WITH A MINIMUM OF 2 SUCTION FITTINGS OF THE ABOVE MENTIONED TYPE.THE SUCTION FITTINGS SHALL BE SEPARATED BY A MINIMUM OF Y AND MUST BE PIPED SUCH THAT WATER IS DRAWN THROUGH THEM SIMULTANEOUSLY THROUGH A VACUUM RELIEF-PROTECTED LINE TO THE PUMP (OR PUMPS)_VACUUM/PRESSURE CLEANING FITTINGS SHALL BE IN ACCESSIBLE POSITION, MINIMUM OF 6"AND NO GREATER THAN 12"BELOW THE MINIMUM OPERATIONAL WATER LEVEL OR BE AN ATTACHMENT TO THE SKIMMERISKIMMERS. A REQUIRED POOL ATMOSPHERIC VACUUM RELIEF SYSTEM SHALL BE INSTALLED AS PER NYS RESIDENTIAL CODE R326(2025)AND IN ACCORDANCE TO TOW CODE 9. ALL ELECTRICAL WORK SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 70(NEC), PRINCIPALLY ARTICLE 680 AND THE NYS RESIDENTIAL CODE SECTION 4102 THROUGH 4106.ALL ELECTRICAL DEVICES MUST BE APPROVED BY UNDERWRITERS LABORATORIES AND BE PROTECTED BY A GOUND FAULT CURRENT INTERRUPER(GFCI).CURRENT CARRYING ELECTRICAL CONDUCTORS EXCEPT FOR THOSE PROVIDING POWER TO POOL LIGHTING AND POOL EQUIPMENT SHALL MEET THE SEPARATION REQUIREMENTS OF TABLE E4203.5. ALL METAL ENCLOSURES,FENCES OR RAILINGS NEAR OR ADJACENTTO THE SWIMMING POOL THAT MAY BECOME ELECTRICALLY CHARGED DUE TO CONTACT WITH AN ELECTRICAL CIRCUIT SHALL BE EFFECTIVELY GROUNDED. 10. WATER SOURCE FILLING THE POOL SHALL BE EQUIPPPED WITH A BACKFLOW PROTECTION DEVICE IAW NYS PLUMBING CODE 608_ COMPANY: 11. ALL PIPING IS DIAGRAMMATIC UNLESS OTHERWISE STATED. 12. WALKS,IF PROVIDED SHALL BE NONSLIP AND SLOPE AWAY FROM THE POOL EDGE. 13. A MEANS OF EGRESS FROM DEEP AND SHALLOW ENDS MUST BE PROVIDED IAW ANSI/NSPI-5 SECTION 6. 14. CONTRACTOR TO PLACE THE POOL IAW TOWN OF SOUTHOLD CODE SETBACKS. 15. ALL DRAINAGE FROM THE POOL SHALL BE MAINTAINED ON THE SUBJECT PROPERTY. ADDRESS: 16 THE DESIGN IS BASED ON A DRAINAGE SOIL WITH<10%SILT.GROUND WATER SHALL NOT EXIST WITHIN THE EXCAVATION. IF GROUND WATER EXISTS WITHIN 00"FROM GRADE,DEWATERING FACILITIES WILL BE REQUIRED. 17 ALL GAS AND OIL WATER HEATERS(IF INSTALLED)FOR THE IN-GROUND SWIMMING POOL SHALL BE NATIONAL APPLIANCE ENERGY CONSERVATION ACT(NAECA)COMPLIANT. POOL HEATERS SHALL BE PROPOSED POOL TESTED IAW ANSI Z21.56 AND SHALL BE INSTALLED IAW MANUFACTURERS SPECIFICATIONS_OIL FIRED POOL HEATERS SHALL BE TESTED IAW UL726. POOL HEATERS SHALL BE LOCATED OR GUARDED TO 1250 BAYVIEW AVENUE PROTECT AGAINST ACCIDENTAL CONTACT OF HOT SURFACES BY PERSONS.POOL HEATERS SHALL BE PROVIDED WITH TEMPERATURE AND PRESSURE-RELIEF VALVES.A BYPASS LINE SHALL BE INSTALLED SOUTHOLD,NY 11971 FROM THE INLET TO OUTLET TO ADJUST WATER FLOW THROUGH THE HATER.POOL HEATERS SHALL BE PROVIDED WITH THE FOLLOWING ENERGY CONSERVATION MEASURES: 17.1 ALL POOL HEATERS SHALL BE EQUIPPED WITH AN ON-OFF SWITCH MOUNTED FOR EASY ACCESS TO ALLOW SHUTTING OFF THE OPERATION OF THE HEATER WITHOUT ADJUSTING THE THERMOSTAT SETTING AND TO ALLOW RESTARTING WITHOUT RELIGHTING THE PILOT LIGHT. AT LEAST ONE THERMOSTAL MUST BE PROVIDED FOR EACH HEATING SYSTEM. HEATED SWIMMING POOLS SHALL BE EQUIPTED WITH A POOL COVER_(exempt FROM THIS ARE OUTDOOR POOLD)DERIVING 20%OF THE ENERGY FOR HEATING THE POOL FROM RENEWABLE SOURCES OVER AN OPERATING SEASON. 172 TIME CLOCKS SHALL BE INSTALLED SO THE PUMP CAN BE SETTO RUN DURING OFF-PEAK ELECTRICAL DEMAND PERIODS,AND CAN BE SET TO RUN THE MINIMUM TIME NECESSARY TO MAINTAIN THE POOL WATER IN A CLEAN AND SANITORY CONDITION IAW APPLCIABLE SANITORY CODE OF NEW YORK STATE_ DATE: 4/28/26 18 BACKFILL WILL BE DONE WITH CLEAN EARTH FREE OF ROOTS AND DEBRIS_ BACKFILL HEIGHT AND WATER LEVEL TO BE WITHIN 8"OF EACH OTHER. PLACE CONCRETE ON SANDY LOAM SOIL. CLAY TO BE REMOVED AND REPLACED WITH SANDY LOAM_ DRAWN BY: C.D. 19 DRAIN REQUIREMENT-SINGLE OR MULTIPLE PUMP CIRCULATION SYSTEMS MUST HAVE A MINIMUM OF TWO SUCTION OUTLETS OF AN APPROVED TYPE,SEPARATED BY A HORIZONTAL OR VERTICAL DISTANCE OF AT LEAST 3 FEET. SCALE: AS NOTED 20 THE POOL WAS DESIGNED REFERENCES AS THE FOLLOWING: pF NF /w- DRAWING TITLE: 20.1 THE RESIDENTIAL BUILDING CODE OF NEW YORK STATE(2025)SEC R328 ✓�` DEF o,A POOL 20.2 THE ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE(2025)SEC R403.10 NOTES 20.3 THE FUEL GAS CODE OF NEW YORK STATE(2025) 20.4 THE NEW YORK STATE SANITORY CODE. SHEET No. 20.5 ANSI/APSP/ICG5 STANDARD FOR RESIDENTIAL IN-GROUND SWIMMING POOLS. �= OA �?_ 20.6 BOCA CODE SECTION 421. Rp 20.7 COMPLIES WITH CODE OF THE TOWN OF SOUTHOLD SI A2