Loading...
HomeMy WebLinkAbout52924-Z ��ofsQ�r�4 TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52924 Date: 04/29/2026 Permission is hereby granted to: Becker D8J Revoc Trt 10909 Grapevine Ln Austin,TX 78759 To: install a generator as applied for. Premises Located at: 380 Washington Ave, Greenport, NY 11944 SCTM#41.4-39 Pursuant to application dated 04/21/2026 and approved by the Building Inspector. To expire on 04/28/2028. Contractors: Required Inspections: Fees: GENERATOR $125.00 CO-RESIDENTIAL $100.00 Total $22S.00 Building Inspector na Wu TOWN OF SOUTHOLD--BUILDING DEPARTMENT 'µ Town Hall Annex 54375 Main Road P. 0. Box 1179 Southold,NY 11971-0959 � �t �� Telephone (631) 765-1802 Fax (631) 765-95 02 ha � ou �dto � n� �. o Date Received e. APPLICATION FOR 1 yu f ry BUILDING PERMIT AW V Sr a, For office use Only PERMIT NO. Building Inspector: Applications and forms must be filled out in their entirety. Incomplete q; applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date OWNER(S)OF PROPERTY: Name:Jane Becker SCTM #1000-41.-1-39 Project Address:28 Washington Avenue, Greenport, NY 11944 Phone#:512-423-7436 Email:beckerjmh@gmail.com Mailing Address:28 Washington Avenue, Greenport, NY 11944 CONTACT PERSON: Name:Ed Reiff 1 Caen Ready Mailing Address: 128 Pulaski Road, Kings Park, NY 11754 Phone#:631-544-0400 Email:office et enread �� .com � y DESIGN PROFESSIONAL.INFORMATION: Name:NIA Mailing Address:N/A Phone#:N/A Email:NIA CONTRACTOR INFORMATION: Name: Ed Reiff 1 Caen Ready Mailing Address: 128 Pulaski Road, Kings Park, NY 11754 Phone#: 631-544-0400 Email:office@getgenready.com DESCRIPTION OF PROPOSED CONSTRUCTION EI New Structure ❑Addition OAlteration ❑Repair ❑Demolition Estimated Cost of Project; 0 other Install a 22kw II uid prow ale generator. $ 17,430.63 Will the lot be re-graded? ❑Yes kNo Will excess fill be removed from premises? nYes *.No 1 ............. PROPERTY INFORMATION Existing use of property:Residence Intended use of property: Residence Zone or use district in which premises is situated, Are there any covenants and restrictions with respect to R_4,o F] this property? ❑Yes ®No IF YES, PROVIDE A COPY. Biox,Aftie�r Rie,aidill Chiei&k The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws..Ordinances or Regulations,for the construction of buildings,, additions,alterations or for removal or demolition as herein described.The appIlcant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and In building(s)for necessary Inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): Eid iff Ge n Ready •MAuthor& ed Agent ClOwner Signature of Applicant: Date: FAI ELLA SEE LI W YORK N PUBLI STATE OF NF f:,A4901831 STATE OF NEW YORK) Registration NO. .,*) I (),uafified,In SuffOlk Colutity 13 0 1C.) GO,Mrr,i,$5jon E)(pJre,s 07-27-2029 COUNTY OF ............ Ed Reiff / Gen Ready being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the Contractor/Agent (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this f 0�,,r c, 20 —day o Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) ,,,Jane Becker residingat,28 Washi ngton Avenue Green dE Ge n R to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Jane Becker Print Owner's Name 2 . .......... .......... BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex 54375 Main Rand Box 1179 PO o Southold, New York 11971-0959 ' Telephone (631) 765-1802 - FAX (631) 765-9502 r � r ,,j rr out' of t,,o nn . oy a°t av ,APPLICATIONR ELECTRICAL INSPECTION .........................-------------------- ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Gen Ready Inc. Electrician's Name: Ed Reiff License No.: ME-2740 Elec. email: office@getgenready.com Elec. Phone No: 631-544-0400 ❑I request an email copy of Certificate of Compliance Elec. Address.: 128 Pulaski Road, Kings Park, NY 11754 JOB SITE INFORMATION (All Information Required) Name: Jane Becker Address: 28 Washington Avenue, Greenport, NY 11944 C ross Street: Main Street Phone No.: 512-423-7436 Bldg.Permit#: email: beckerjmh@gmail.com Tax Map District: 1000 'ection:41 Black: 1 Lot: 39 ... .........................................------------- BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please y)FOOTAGE Print Clean Install a 22kw liquid propane generator, Square Foots e: Circle All That Apply: Is job read for ins ection? YES NO [:]'Rough In Final Y p � Do you need a Temp Certificate?. YES NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A # Meters Old Meter# New Service❑Fire Reconnect[]FIood Reconnect FISery i ce Reco n n ect El U n de rg round Dove U�nd�e�r �r and Laterals 1 2 H Frame Pole Work done on Service? Y LJ 11 Additional d'itional Information: Y UE WITH APPL.1,01ATION S.C.T.M. NO. DISTRICT:1000 SECTION:41 BLOCK: 1 LOT(S):39 LOT 7 LOT 8 , LION. PIPE _., 0.2E 2 9.94 REmvNs OF , x C ,D 0., LOT 19 vs co UMN LOT 22 w z LOT 21 LOT 20 �. ROOF Off` � �+ x I IO +► SIC 3 .4 MO E CK ; 1lk ` CONC. CONC. CQ SCR COLUMN w w CON �� � .. COLU U. . "A"""" ESE 06F ILs A � C � C" WASHINA ,GTON .o THE WATER UPPLX, MLA, R ANO"SWOOL UPDATE SURVEY 02-02-16 L,OCA77ONS SHOW ARE FRO AND OR DATA,09 wwv FROM'07NM AREA: 9,554.10 SQ.FT. 0r 0.22 ACRES ECEVAn DATUM.' � VE 1S"A T10N SEC11 THEE`NE K STATE ED LEAP LAB"A SERE SNAG ,0 ���� C14 OF THIS SURVE RU 1�NOT SEARING THE,LANO S"RI 'S" MDO SEAL AU BEHALF IH PERSON FOR 1N THLc,SiVR" 1S PREPARED AND ON HIS St' To ME 11 MD TO BEE �'A COPY,'E "° AND LENNOf)O INS"T�1 TON L?NL"HERE" AND TO THE ASSIGNEES LENDING,1NS77, . GUARANTEES ARE NNOTTRANSFER OX THE OFFSE7S OR&MENWONS I E'R" 1NES THE`S "TURES°A�R A SP6-01 'C PURPOSE"AND USE WEE ORE'rNE AR,E; NR'OT`ONTEND'ED T0',MONUMENT 'I HE RROPERrY LANES'OR TO OUW 11,E ERE077ON OR EEN'=ADD1T10NAL S7j?UC7VRES OR AND OINER"IMPROWMENTS EA ENTS AND 1R L OSLJ"R"EA STRU RES RECORDED'OR UNRECORDED ARE NOT O AR"AN UNLESS EHYSICA,LL' EIAi ENT"ON THE PREMISES'A1"INC T11�ME OF SURVE SURVEY OF: LOTS 2 1 0 & 21 INCL. CERTIFIED TO..DANIEL O. BECKER, MAP OF: WASHINGTON HEIGHTS JANE V 9ECKER FILE©:DEC. 29, 1927 N0.651 STEWART TITLE COMPANY,, SITUATED AT. GREENPORT TOWN OR SOUTHOLD KENNETH ,OYC S Gw PLLC SUFFOLK COUNTY, NEW YORK Profe a o A n e, Design P.O. Box 153 Aquebogue, New York 11931 2015 Psorr>3(ssi)2ae—i5ae FAX(egi)29e-5ee FILE, 15-124 SCALE:1"=20' DATE:AUG. 21, N.rS USC. No. 0soe$2 � tba=ema.or IWbart J.HaftvaW&nth Y.soyvhnk S GENERACO GENERAC AIR-COOLED STANDBY 22-28 kW1 GENERATOR Residential/Commercial Standby Generator INCLUDES: STANDBY POWER RATING G007260-0;G007325-0(Aluminum-Metro Gray)-22kW 60 Hz • Cellular connectivity standard,with Wi-FiT'and Bluetooth'" capabilities G007261-0;G007326-0(Aluminum-Metro Gray)-24kW 60 Hz G007327-0;G007328-0(Aluminum-Metro Gray)-26kW 60 Hz • Electronic fuel and ignition control(EFIC) G007282-0;G007329-0(Aluminum-Metro Gray)-28kW 60 Hz • Hydraulic lifters • Smart Exercise Technology • True Power'" Electrical Technology • Power Zone" 200 Controller { • Oil level sensor 0 200 Am service rated transfer switch in bundled models P f �< • Electronic governor e System status&maintenance interval LED indicators SAC • Sound attenuated enclosure • Natural gas or LP gas operation • ecobee by Generac Smart Thermostat included in select bundles OUR. • 5 Year limited warranty,generator and transfer switch � QU' n • Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in(457 mm)to a structure.` NOTE: CETL certification only applies to unbundled generator 'Must be located away from doors, windows,and fresh air intakes and in units. Units bundled with the transfer switch are ETL certified in the USA only. accordance with local codes, FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of O MOBILE LINK® CONNECTIVITY: Standard with the Generac Air-Cooled Generac's success in providing the most reliable generators possible. Standby Generator home standby generators,Mobile Link Cellular allows users Generac's G-Force engine lineup offers added peace of mind and reliability for to monitor the status of their generator from anywhere using a smartphone, when it's needed the most.The G-Force series engines are purpose built and tablet,or PC.Easily access real-time operating status,maintenance alerts,and designed to handle the rigors of extended run times in high temperatures and generator readiness. Users can also connect their account to an authorized extreme operating conditions. service dealer for proactive support and streamlined service.With Mobile Link, users can see their generator is ready before the next power outage. O TRUE POWER" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality O SOLID-STATE VOLTAGE REGULATION: This state-of-the-art power power.This allows confident operation of sensitive electronic equipment and maximizing regulation system is standard on all Generac models. It provides micro-chip based appliances,such as variable speed HVAC systems. optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge O TEST CRITERIA: loads to the engine.Digital voltage regulation at±1%. ✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer ✓ SYSTEM TORSIONALTESTED ✓ MOTOR STARTING ABILITY network provides parts and service know-how for the entire unit, from the O ecobee by Generac SMART THERMOSTAT:This new energy manager for the engine to the smallest electronic component. home offers a seamless integration into the Generac ecosystem,managing the O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous home's HVAC systems(s)and protecting the generator from potential overloads with GENERAC POWER SYSTEMS. One reason for this confidence is that the with precision. Leveraging Mobile Link, users may also view the status of the GENERAC product line is offered with its own transfer systems and controls for generator and the LP tank level(if applicable). total system compatibility. "J GENERAC ,������ GENERAC' LL PROMISE '����' *� Mobile Link- roYew° �Ax'µ, 'AssemDkdlnMe USAusirm domesdcandlaelan r>ark. GENERAC® Features and Benefits Engine • Electronic fuel and ignition control-EFIC Improves generator performance by automatically adjusting for the changing environment.Improves fuel efficiency and reduces emissions on average. • Hydraulic lifters Automatically maintains optimal valve spacing.No more manually adjusting valves required. • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly ' rings help the engine run cooler,reducing oil consumption and supporting longer engine life. • Cast iron cylinder walls Rigid construction and added durability help prolong engine life. • Full pressure lubrication system Pressurized lubrication to all vital bearings facilitates better performance,less maintenance,and longer engine life.Featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection helps to prevent catastrophic engine damage due to low oil. • Oil level sensor Continuously monitors and reports engine oil levels. • High temperature shutdown Helps prevent damage due to overheating. • Electronic governor Maintains constant 60 Hz frequency. Generator • Revolving field Allows for a smaller,light weight unit which operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to ±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Power Zone Controls • AUTO/MANUAUOFF/SERVICE buttons with LED Select the operating mode and provides easy,at-a-glance status indication in any condition. indicators • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • External LED indicators Adjustable brightness LED indicators to communicate system status and maintenance intervals. • Smart Exercise Allows the system to skip its scheduled exercise if the generator ran for more than 5 consecutive minutes within the 72 hours prior to a scheduled exercise event,allowing for fuel cost savings to the owner. • Utility voltage sensing Constantly monitors utility voltage,with adjustable dropout(75-80%)and pickup(84-89%)of nominal voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1,500 seconds from the factory default setting of 10 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load.Adjustable 0-60 seconds by a qualified dealer(factory default setting 5 seconds). • Engine cool-down Allows engine to cool prior to shutdown.Adjustable 60-1,500 seconds by a qualified dealer(factory default setting 60 seconds). • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every week.Also offers a selectable setting for weekly,bi-weekly,or monthly operation with an adjustable run time from 5 to 20 minutes,and an option for a low speed engine rpm,providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with AGM-style batteries. • Generator emergency shutdown A recessed button on the outside of the enclosure for emergency personnel to use to perform an emergency shutdown of the generator. GENERAC" Features and Benefits Unit • SAE weather protective enclosure Sound attenuated enclosure provides quiet operation and weather protection,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed muffler Quiet muffler is mounted inside the unit. • Small,compact,attractive Makes for an easy,aesthetically pleasing installation,as close as 18 in(457 mm)away from a structure. Must be located away from doors,windows,and fresh air intakes and in accordance with local codes. • Main line circuit breaker Protects generator from overload. Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity • Generator status Monitor the generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • f aintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. • Configurable exercise and duration Select Low Speed Exercise,Smart Exercise,or Transfer on Exercise options.Adjust generator to exercise for 5-20 minutes(5 minute default). • Installation and service application Generator installers and service technicians must use the Field Pro mobile application when installing or servicing the generator. GENERAC® Specifications Generator Model 22 W 24 W 26 kW 28 W maximum—nfin6-q k6lpa6ity(LP) 2. Rated maximum continuous power capacity(NG) 21 kW* 22.5 W 24 kW*,-, 25 W Rated maximum continuous load current-240 Volts(LP NG) 100/94 108/1-00 116/104 Main line circuit breaker 7 00 amp J'110 amp 125 amp Number of rotor poles 2 2 6CH Power factor 1.0 ts AGM / i7-.9 6 PoWJe Unit weight(lb kg) 451/205 ---461-/209 524/238 X WW X 7�17- r7- — _ 7 6Xx2& x-§-0Y, i Sound output in dB(A)at 23 it(7 m)with generator operating at normal load** 67 67 67 67 [S7oL Lnd'�7�p "-,7k 7 Exercise duration Adjustable 5-20 min(5 min factory default) Engine -GENERAC G Force 101 Serves Number of cylinders 2 Cylinder block Aluminum w/cast iron sleeve Valvearrahgement Lifter type Hydraulic Governor system Electronic jpo _gn,ratio r Starter ifig 77. 12 VDC K T§ Operating rpm p 3,600 7- qonsumption `Natural as PP 1/216 182(515)µ Full load dd�L 311'(8 8 0) 2 ",2 3') 3 4.1 uid Propane lj 74,(2:-05),[7.74], !'85:(�.tl)jj�.g3f' 8 7,1 "02"' F p rn �e ip' ad ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)to r LP gjoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). **Sound levels are taken from the front the generator Sound levels taken from other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby: Applicable for supplying emergency power for the duration of the utility power outage.No overload capability is available for this rating.(All ratings in accordance with BS5514,IS03046 and DIN6271).*Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content,ambient temperature,humidity,barometric pressure,altitude, engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 It(304.8 m)above sea level;and also will decrease approximately 1%for each 10 IF(6 IC) above 60 IF(16 T). GENERAG' Specifications Controls Mode buttons AUTO - Autotnatic'start on utility-failure.Programmableexerciser-- MANUAL -- Start with starter control,unit stays on.If utility fails,transfer to load takes place. OFF -7 t SERVICE For diagnostic personnel use to prevent remote commands for safe interaction,and prevent nuisance Mobile Link notifications during diagnostic testing. 7 7 M-40(o Engine Run Hours indication Standard _7 7-,7-' 7 �af Utility nominal voltage setting Adjustable to greater than or less than 10%of 240V,(90-110%,default 100%). r4 Utility o@jiis�P(Lroncq!setting) -,"'J Adjustable tiii against @�i ftid��se -6 jus ..a Future Set Capable Exerciser/Exercise Set Error warning Standard 7 Ep .7_7 -..7.50!events each Engine start sequence Cyclic cranking:Engine cranks a maximum of five times at factory set intervals and durations. jStarti r lock out Starter cannot re engage rPt(I jec afterhas stopped _ Smart battery charger Standard 77, Low Battery/BatteryProblem Protection. ;�algattery Condition Standard indication Under-Frequency/Overload/Stepper Overcurrent protection Standard Automatic Low Oil Pressure/High Oil Temperature shutdown Standard LDver­d�n�O_WrTppe shutdown High Engine-Temperature shutdown Standard _7_ LI r Ktr aaiqu�CtCd��L t� q§k ...... 6 ard Common external fault capability Standard dar .,Star) GENERAC® 1 Transfer Switch Specifications Service Rated Switch Features • Includes fuse control module(FCM)standard. G007325-0 220,G007326-0 24kW • Inte rated sure rotection. Model 9 9 P G007328 0 26kW,G007329 0�28kW; • Energy Management sold separately. 9 of-poles 2 � " • Electrically operated,mechanically-held contacts for fast,clean connections. Current rating(amps) 200 • Rated for all classes of load,80%continuous load,both inductive and resistive. Volta a rahn AC y,. .120%290 1H �.r.• 2-pole,250 VAC contactors. C_._ 9._ 9_N_r) wr�. _ • Service equipment rated,dual coil design. ETL or UL listed Enclosure type Standard NEMANL 3R ry • Rated for both aluminum and copper conductors. ECucuityb_reaker protected_;�,rx y 4 "y 22000 : • Main contacts are silver plated or silver alloy to resist welding and sticking. Lug range _ 250 MGM-#6 • NEMA(UL 3R aluminum outdoor enclosure allows for indoor or outdoor Surge;protecbon. N r` ahtegrated surge protection mounting flexibility. Weight 39.0 lbs(17.7 kg) • Includes installation fast mount. LETL7 Dimensions Height Width - Depth H1 H2 W1 W2 f C t f GENERAC -] in 26.75 30.1 10.5 13.5 6.3 cm 67.95 76.45 26.67 34.3 16.01 Wire Ranges F r r Conductor Lug Neutral Lug Ground Lug ,1 - a 250 MCM-#6 350 MCM-#6 2/0-#14 DE" Smart Thermostat Specifications ecobee by Gendrac Smart Thermostat Features • Built-in HVAC energy management. Model 0007329-0(28kW) • Generator and LP tank status. Smart Ttiermostatmodel z Enhanced • Controls one-wire HVAC accessories(humidifier,dehumidifier,etc.) • Includes Power Extender Kit(PEK)for common(C)wire needs. Power supply source 24 VAC(from HVAC equipment transformer via • Includes optional trim adaptor plate. line input) • 4 in full-color touch screen LCD. C , "� Conventional(2H/2C)heat pump(3H/2C)2 System aompahbihty 'stage heat+„2 stage;cooU+1°stage AUX • Mobile Link and ecobee remote monitoring homeowner applications. boilers 3's e4,EL__ • Energy Star®certified. -• _r __ - . _ ____. peed PTACs,or�fan`coil units • 5 year limited warranty. rCompliance Energy Star FCC Part 15 Class B,UL 916 LW rogrmmals _. .0 RAG Y1 Y2,W1«,W2/OB,FEK+ Dimensions User configurable temperature range Display:40OF to 100°F(5°C to 371C) (Operahhg temperature rating„ Z 14`F to`122°F:(=10:'C to 50°C) Height Width Depth Weight 1.1 lb(0.49 kg) in 4.09 4.09 0.94 cm 103.89 103.89 23.88 . � GENERACO Axa^Ua0nUe Accessories Prod n. VddW#. SC Ycl A0006487350 AGM Group BTX20L Battery Every standby generator requires a battery to start the system.Generac offers the recommended battery for use with Air-Cooled Standby Generators. GOOT21�-O Battery Heater The battery heater wraps around the battery.Recommended for use if temperature regularly falls below 32'F G007102-1 Oil Heater Oil heater slips directly over the oil filter.Recommended for use if temperature regularly falls below 32'F(0 G007103-2 Breather Heater Breather heater is for use in extreme cold weather applications where heavy icing occurs.Recommended for use if the temperature regularly falls below 0'F(-18'C). G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that I Contact Kit may not be needed.Not compatible with 50 amp pre-wired switches. G009918-0-Metro Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch-up the paint to protect from future Gray corrosion.The touch-up paint kit includes the necessary paint to correctly maintain or touch-up a generator G007216-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance I on an air-cooled standby generator(oil not included). G007009-0 LTE LP Tank Fuel Level The JE enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.. Monitor Monitoring the LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Status alerts are available through a free application to notify users when the LP tank is in need of a refil I. G007000-1 (50 amp) Generac Load Manager Generac:Load Managers(LMs)are used to optimize the performance of a standby generator.They manage large G007006-1 (100 amp) electrical loads upon startup,and shed them to aid in recovery when overloaded.In many cases,using LMs can reduce the overall size and cost of the system. Dimensions & PCs Model UPC `= LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. Go»onm Power Systems,Inc. | S45WQ9aoo HWY.oo | Waukesha,W|o318o | gonomo.00m Part No.AUVV5151077 @2025 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice. Rev.ooT01/2U2o