Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
52421-Z
of S°°Tyo`o Town of Southold * P.O. Box 1179 r 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46841 Date: 02/11/2026 THIS CERTIFIES that the building BATTERY STORAGE Location of Property: 540 Longview Ln Southold, NY 11971 Sec/Block/Lot: 88.4-52 Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 09/23/2025 Pursuant to which Building Permit No. 52421 and dated: 10/31/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Battery storage to existing single family dwelling as applied for. The certificate is issued to: Henry Waslo ,Karin Waslo Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 2025-1167152 12/22/2025 PLUMBERS CERTIFICATION: A hors ed S gn re ho��,oFsvaryo(o TOWN OF SOUTHOLD BUILDING DEPARTMENT • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52421 Date: 10/31/2025 Permission is hereby granted to: Henry G Waslo 540 Longview Ln Southold, NY 11971 To: Install Powerwall ESS to existing single family dwelling as applied for. Premises Located at: 540 Longview Ln, Southold, NY 11971 SCTM#88.-4-52 Pursuant to application dated 09/23/2025 and approved by the Building Inspector. To expire on 10/31/2027. Contractors: Required Inspections: Fees: Battery Storage $100.00 CO-RESIDENTIAL $100.00 Tot 200.00 Building Inspector _ q •e is - . �/�, �h� � , ����tRi�I% •.•j v:/.-ax'kt, Yi4" .,:�,.�, ,_;.,-:,...,y, ..,q..;,. i:....�;..;t',.c.. o:K..�,�. :-�K..,L l: 1 Electric allns ecto , Inc. 2025-1167152 *; Southold,Town Of 's Inspector: 115 "t z. New York:Board of Fire Underwriters Issue Date: 12/22/2025 J� 300 East Meadow Avenue East Meadow,NY 11554 T' � '.Y Office: (516)794-0400(631)650-0200 F, Website:www.eiiny.com Mail To: Property Address: ' SUNation Solar Systems,Inc. Karin&Henry Waslo �.. 540 Longview Lane 171 Remington Boulevard Southold NY 11971 Ronkonkoma NY 11779 License# Scott Maskin 33412-ME 40325-ME ELECTRICAL APPROVAL CERTIFICATE Section:88 Block:4 Lot: 52 Permit: 52421 ..+ AREAS LISTED BELOW ARE APPROVED BY Inspection AND FOUND TO BE IN COMPLIANCE WITH THE BUILDING CODE OF NYS AND CURRENT PROMULGATED NEC No visual defects were found for the electrical inspection provided.No obvious unsatisfactory conditions `s; l/ I were found in the areas herein below only. `` I Residential Inspection Final Approved 12/17/2025 ' chi (1)Tesla Powerwall 3-AC Rating 11.5,Total Rating 13.5kWhrs.• L, es ;�; G .,. ,.:rl•o-e.j kaki='%;:<a.i i6:�i h•,�, This electrical inspection and certificate does not take into account any FEMA,NYS and local flood ■ �i !` elevation requirements.It is the responsibility of the roe owner to determine if flood elevation requirements apply. NYBFU and Ell are not responsible or any Flood Elevation requirements. Therefore this electrical certificate is only for compliance of NYS Electrical and NEC Codes. \ - •» .e Richard M. Bivone Philip t. Goehring,Jr. ■ % `. r President f � 1 '' Chie Electrical Inspector .gbh. •,i,.:L o' • This document features a tamper proof Quick Response code which contains the encrypted original data submitted when certificate was issued. n- <e ,i"b'r. �Z�i :i. .•v."q�'.�..� \\��'y e-<.,��r/// �`'. `.?��/ \�,f•? v.' /// •• \\�, ,":.:.e/ \, 'a`b 4 � .',�y• �t ... \ Co,r= .r = _ •S`�r• fr w�„i ,,.. _ �.t.°n :. .., y `a�•�•ra ,. �tirr• -e ,� �C�n �, ,i`O +' oe, � r e•�T`•' � e�1•''' '�°'�� ' yer'�,r ,n ev'?.. M � P7 �� e�'A•' �9e a� teaL•dsi:% � •Y�_ .s� V::�� ��;P111;}i. � 1,'/1,01�i� t•�J.,;�/�.1Y�. ��'Y,��y�CA. t�:'^,e:�i� :eey�► 1. EI,V_gllt$II,AI,INSPECTORS, INC. is not responsible for the existing conditions located at the subject premises. ti Lz ,V- �, Y.f 2. E 1° C,AL �PJM i I� � � INC. is not responsible for corrections, upgrading or replacement of existing r �. F_r electrical violations at the sn 1'ecGpremises. Any corrective work shall be Solely the responsibility of the property n- owner JLF,i1i I AL SP ; "'FORS, INC. ROES NOT WARRANTY OR UNDERWRITE TIDE ELECTRICAL C®N�I8=.4) S "I-"I'HE PREMISES. 3. ELECTRICAL INSPECTORS, INC. only recognizes the National Electric Code,the Building Codes of New York Slate all velumes and Local Municipal Codes,as Authorized by The Departinent of State Codes Division, via Village,Tob %n or City Board FZesolution. 4. AN ELECTRICAL SURVEY consists of a visual°examination of the premises ONLY:Electrical Inspectors Inc. Will comply with the requiremenls of NFPA 73,latest edition Chapter 1, Section 1-1, 1-2. If violations exist, a Notice ol'Violation(NOV)will be issued requiring corrections by a licensed electrical contractor. After the violation has been corrected, a re-inspection will be conducted and ifapproved a ecrtificate shall be issued. 5. AN ELECTRICAL C1,OSEn WALL,INSPECTION consists ol'a visual examination of the area requested ONLY: Fdcctrical Inspectors Inc. will comply with the requirements ofNFPA 73, latest edition Chapter 1, Section 1-1, I f% olatiFv s exist. ;i Notice of Violation (NOV) will be issue(]requiring corrections by a licensed electrical contractor. After the violation has been corrected,a re-inspection will be conducted and ifapproved a certificate shall be issued. 6. A doer; not examine the actual wiring or devices unless all walls are opened and wires and devices arc cXposcd prier to the surwTy buiMl conducted. 7. A CE.R"1'IFiCATI,: is non-translerahle. 8. AN ELECTRICAL I NSPEC"PION consists of an examination ofwiring and installations during the rough stages ofconstriiction. Aftei,completion ol'thc construction a final inspection will be conducted at which time a certificate will be issued provided no violation exists. In the event an inspection is not requested during the rough stages ol'construction ELECTRICAL.INSPECTORS, INC. will perform a CLOSED WALL SURVEY that consists of a visual inspection of the mring and installations only. Since access is limited, ELECTRICAL INSPECTORS, INC. shall bear no, responsihilily for any detects or violations at the premises. 9. ELECTRICAL INSPECTORS,INC. shall not be responsible to remove any walls in order to conduct an electrical inspection. 10. ELECTRICAL INSPECTORS, INC. will only release information, certificates and reports to the applicant after payment for services rendered have been paid in Cull. 11. ELECTRICAL INSPE'C'TORS, INC.assumes no liability for the results of its inspections. 12. The agreement may not be chaMIcd orally. 13.The New York Board of Fire Underwriters, Inc., is a subsidiary of'Electrical Inspectors, Inc. It is bully operational and functional and performs electrical inspections as it always has. 1.1."flee Ne,v Fork Board of Fire Underwriters, Inc. and Electrical Inspectors, Inc. inspects properties for compliance with the Building Code of the State of New York,counties and local electrical codes,as well as the promulgated NEC (National l,;lectrical Code). OE SOUTyo� * TOWN OF SOUTHOLD BUILDING DEPT. Couto 631-765-1802 JZ�` l INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] NSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL&4� 4YWIe, [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE OY INSPECTOR Fisher Engineering Services, P.C. 373 Aurora Way • Bluffton • SC 29909 Phone: (631) 786-4419 December 12, 2025 Town of Southold Post Installation Certification Subject: Engineer Statement for Integrated Energy Storage System Waslo Residence - 540 Longview Lane, Southold, NY 11971 Permit No: 52421 Installation Date: 12/4/2025 Inspection Date: 12/8/2025 Fisher Engineering Services, P.C. certifies that the energy storage system at the above referenced residence has been installed properly in accordance with the approved plans and manufacturer's specifications and is certified to be in compliance with the minimum requirements of the Town, the 2020 New York State Residential Building Code, 2018 International Residential Code (2018 IRC), Long Island Unified Solar Permit Initiative (LIUSPI), National Electric Code NFPA 70/2020, and the provisions of ASCE 7-16. G. FISy Rfi Sincerely, - ��,, FES o IA N 1 3 @26 William G. Fisher, P.E. Licensed Professional Engineer Architectural Design•Residential•Light Commercial Additions•Extensions•Conversions Construction Estimates/Oversight•Expediting•Inspections FIELD INSPECTION REPORT DATE COMMENTS N � FOUNDATION (1ST) R� ------------------------------------ FOUNDATION (2ND) tCOO 17 � z 0 H ROUGH FRAMING& PLUMBING H �t vl r INSULATION PER N.Y. STATE ENERGY CODE 10 K u FINAL ADDITIONAL COMMENTS A D 1 o ( 2 0 Lk \C VS F 0 �Z m t� k � y �O Jz x H x e b y PROPERTY INFORMATION Existing use of property:Residential Intended use of property: Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes @No IF YES, PROVIDE A COPY. ❑ Check Box After Reading: ,The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,'alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors on premises and•in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State,Penal Law. Application Submitted By(print name): S Ott Maskin @Authorized Agent ❑Owner Signature of Applicant: Date: - ._ . _ . ._.__. . . . _ .. . STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Scott Maskin being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent, Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this I 1 �c1 day of C'M6 /' .20�5 V Notary Pubtir LYNN VITA votary Public, State of New York Registration :#01 V15068399 Coun PROPERTY OWNER AUTHORIZATION,,CommissionlifiedlExpireslOCt 28 20� (Where the applicant is not the owner) . Karin Waslo residing at 540 Longview Lane Southold do hereby authorize Scott Maskin to apply on my behalf to the Town of Southold/rBuilding Department for approval as described herein. —4A— AZZ '?I Owner's Signature Date Karin Waslo Print Owner's Name 2 ,,I BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD cm '` Town Hall Annex - 54375 Main Road - PO Box 1179 v= Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerre-southoldtownny.gov— seandc@,southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: SUNation Solar Systems, Inc Name: Scott Maskin License No.: 33412-ME email: permittingasunation.com Address: 171 Remington Blvd. Ronkonkoma NY 11779 Phone No.: 631-750-9454 JOB SITE INFORMATION (All Information Required) Name: Karin Waslo Address: 540 Longview Lane Southold NY 11971 Cross Street: Phone No.: 516.456.4045 Bldg.Permit#: email: kbwaslo mail.com Tax Map District: 1000 Section: 88 Block: 4 _ Lot: 52 BRIEF DESCRIPTION OF WORK(Please Print Clearly) Installation of (1) PowerwalB Battery Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect-Service Reconnected - Underground -Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection Formals Fisher Engineering Services, P.C. 373 Aurora Way• Bluffton • SC 29909 Phone: (631)786-4419 September 18, 2025 Attention: Town of Southold Building Department Subject: Engineer Statement for Energy Storage System Installation Waslo Residence- 540 Longview Lane, Southold,NY 11971 1 have reviewed and certify that the manufacturer's guidelines and equipment for the proposed Tesla Powerwall 3 Energy Storage System being added to the existing photovoltaic system and storage for the above residence meet the requirements for the 2020- Residential Code of New York State (2020 RCNYS), Long Island Unified Solar Permit Initiative (LIUSPI), 2017 National Electric Code,NFPA 70/2014 1 hope that this letter serves and meets with the approval of the Building Department. Sincerely, 0��JF';V y og ^� v' G. F1SyF e ^� U � 3 William G. Fisher, P.E. Licensed Professional Engineer sF' °r. dSyoaPM Architectural Design•Residential•Light Commercial Additions•Extensions•Conversions Construction Estimates/Oversight•Expediting•Inspections k Powerwall 3 Power Everything Powerwall 3 is a fully integrated solar and battery system,designed to accelerate the transition to sustainable energy. Customers can receive whole home backup,cost savings,and energy independence by producing and consuming their own energy while participating in grid services.Once installed,customers can manage their system using the Tesla App to customize system behavior to meet their energy goals. Powerwall 3 achieves this by supporting up to 20 kW DC of solar and providing up to 11.5 kW AC of continuous power per unit. It has the ability to start heavy loads rated up to 185 LRA,meaning a single unit can support the power needs of most homes. Powerwall 3 Expansions make it easier and more affordable to scale up customers'systems to meet their current or future needs. Powerwall 3 is designed for fast and efficient installations,modular system expansion,and simple connection to any electrical service. E � V illl �, z 2024 Powerwall 3 Technical Specifications System Technical Model Number 1707000-xx-y Specifications Nominal Grid Voltage(Input&Output) 120/240 VAC Grid Type Split phase Frequency. 60 Hz Nominal Battery Energy 13.5 kWh AC' Nominal Output Power(AC) 5.8 kW 7.6 kW 10 kW 11.5 kW Maximum Apparent Power 5,800 VA 7,600 VA 10,000 VA 11,500 VA Maximum Continuous Current 24 A 31.7 A 41.7 A 48 A Overcurrent Protection Device 30 A 40 A 60 A 60 A Configurable Maximum Continuous Discharge 15.4 kW 3 Power Off-Grid(PV Only,-200C to 25°C) Maximum Continuous Charge Current/Power 20.8 A AC/5 kW (Powerwall 3 only) Maximum Continuous Charge Current/Power 33.3 A AC/8 kW (Powerwall 3 with up to(3)Expansion units) Output Power Factor Rating 0-1(Grid Code configurable) Maximum Output Fault Current(1 s) 160 A Maximum Short-Circuit Current Rating 10 kA Load Start Capability 185 LRA Solar to Battery to Home/Grid Efficiency 89%1.4 Solar to Home/Grid Efficiency 97.5%5 Power Scalability Up to 4 Powerwall 3 units supported Energy Scalability Up to 3 Expansion units(for a maximum total of 7 units) Supported Islanding Devices Gateway 3,Backup Switch,Backup Gateway 2 Connectivity Wi-Fi(2.4 and 5 GHz),Ethernet,Cellular(LTE/4G5) Hardware Interface Dry contact relay,Rapid Shutdown(RSD)certified switch and 2-pin connector,RS-485 for meters AC Metering Revenue Grade(+/-0.5%,ANSI C12.20) Protections Integrated arc fault circuit interrupter(AFCI),Isolation Monitor Interrupter(IMI),PV Rapid Shutdown(RSD)using Tesla Mid-Circuit Interrupters Customer Interface Tesla Mobile App Warranty 10 years 'Values provided for 25°C(77T),at beginning of life.3.3 kW charge/discharge power. 2 See Powerwall 3 Installation Manual for fuse requirements if using fuse for overcurrent protection. 315.4kW off-grid maximum continuous discharge power is only available if on-grid rating is 11.5 kW.If enabled,Powerwall 3 must be installed with an 80 A breaker and appropriately sized conductors. 4Typical solar shifting use case. r,Tested using CEC weighted efficiency methodology. BThe customer is expected to provide internet connectivity for Powerwall 3;cellular should not be used as the primary mode of connectivity.Cellular connectivity subject to network operator service coverage and signal strength. 2 Powerwall 3 Datasheet r .j a Powerwall 3 Technical Specifications Solar Technical Maximum Solar STC Input 20 kW Specifications Withstand Voltage 600 V DC PV DC Input Voltage Range 60—550 V DC PV DC MPPT Voltage Range 60—480 V DC MPPTs 6 Maximum Current per MPPT(Ij 15 A7.a Maximum Short Circuit Current per MPPT(I_) 19 AB 7Only applicable to Powerwall 3 units with 15 A IMP on the product label.Otherwise,Powerwall 3 has an IMP of 13 A. e When PV strings are combined on the roof and the DC input current exceeds the MPPT rating,a jumper can be used to combine two MPPTs into a single input to intake DC current up to 30 A IMP/38 A Isc(or 26 A IMP/30 A Isc if Powerwall 3 is labeled with 13 A IMP/15 A Isc) Environmental Operating Temperature -200C to 50°C(-4°F to 122°F)9 Specifications Operating Humidity(RH) Up to 100%,condensing Storage Temperature -200C to 300C(-4°F to 86°F),up to 95%RH,non- condensing,State of Energy(SOE):25%initial Maximum Elevation 3000 m(9843 ft) Environment Indoor and outdoor rated Enclosure Rating NEMA 311 Ingress Rating IP67(Battery&Power Electronics) IP55(Wiring Compartment) Pollution Rating PD3 Operating Noise @ 1 m <50 db(A)typical <62 db(A)maximum 9 Performance may be de-rated at operating temperatures above 40°C(104°F). Compliance Certifications UL 1741,UL 9540,UL 9540A,UL 3741,UL 1741 PCS, Information UL 1741 SA,UL 1741 SB,UL 1973,UL 1699B,UL 1998, CSA C22.2 No.0.8,CSA C22.2 No.107.1,CSA C22.2 No. 330,CSA 22.3 No.9,IEEE 1547,IEEE 1547A,IEEE 1547.1, CA Rule No.21 Grid Connection United States and Canada Emissions FCC Part 15 Class B,ICES 003 Environmental RoHS Directive 2011/65/EU Seismic AC156,IEEE 693-2005(high) Fire Testing Meets the unit level performance criteria of UL 9540A 2024 Powerwall 3 Datasheet 3 Powerwall 3 Technical Specifications Mechanical Dimensions 1105 x 609 x 193 mm(43.5 x 24 x 7.6 in)10 Specifications Total Weight of Installed Unit 132 kg(291.2 lb) Weight of Powerwall 3 124 kg(272.5 lb) Weight of Glass Front Cover 6.5 kg(14.5 lb) Weight of Wall Bracket 1.9 kg(4.2 lb) Mounting Options Floor or wall mount 10These dimensions include the glass front cover being installed on Powerwall 3. O Oo O 1105 mm 609 mm ►I �193 mm 2024 Powerwall 3 Datasheet 4 W Powerwall 3 Expansion Technical Specifications Battery Technical Model Number 1807000-xx-y Specifications Nominal Battery Energy 13.5 kWh Voltage Range 52-92 V DC" "Powerwall 3 Expansion units are connected in parallel and are not field serviceable. Environmental Operating Temperature —20°C to 50°C(-4°F to 122°F)'2 Specifications Operating Humidity(RH) Up to 100%,condensing Storage Temperature —20°C to 30°C(-4°F to 86°F),up to 95%RH,non- condensing,State of Energy(SOE):25%initial Maximum Elevation 3000 m(9843 ft) Environment Indoor and outdoor rated Enclosure Rating NEMA 313 Ingress Rating IP67 Pollution Rating PD3 12 Performance may be de-rated at operating temperatures above 40°C(104°F). Compliance Certifications UL 1973,UL 9540 Information Mechanical Dimensions 1105 x 609 x 168 mm Specifications (43.5 x 24 x 6.6 in)13 Total Weight of Wall- 118.5 kg(261.2 lb) Mounted Expansion Unit Weight of Expansion Unit 110 kg(242.5 lb) 0 Weight of Glass Front 6.5 kg(14.5 lb) Cover Weight of Wall Bracket 1.9 kg(4.2 lb) 1105 mm Weight of Expansion 0.7 kg(1.5 lb) Accessories Mounting Options Floor or wall mount Stacking Capability Up to(3)Expansion units (Floor Mount Only) behind a Powerwall 3 Compatibility with Only compatible with Other Systems Powerwall 3 Connection to Powerwall 3 Expansion Powerwall 3 or Expansions harness 14 �609 mm� �mm 168 13These dimensions include the glass front cover being installed on Powerwall 3 Expansion. '"The Powerwall 3 Expansion harness is a listed component of the UL 9540 certification. 2024 Powerwall 3 Datasheet 5 v , Solar Shutdown Device Technical Specifications The Solar Shutdown Device is a Mid-Circuit Interrupter(MCI) and is integral to the rapid shutdown (RSD)function required for rooftop PV systems in accordance with Article 690 of the NEC.When paired with Powerwall 3,solar array shutdown is initiated by an External System Shutdown Switch or the On/Off Enable switch located on Powerwall 3.Systems not subject to rapid shutdown requirements must still install one or more MCIs for functional purposes;see the Powerwall 3 installation manual for details. Electrical Model MCI-1 MCI-2 MCI-2 Specifications High Current Nominal Input DC Current Rating(Imd 13 A 13 A 15 A Maximum Input Short Circuit Current(Isc) 19 A 17 A 19 A Maximum System Voltage 600 V DC 1000 V DC 15 1000 V DC15 Maximum Disconnect Voltage16 600 V DC 165 V DC 165 V DC 15 Maximum System Voltage is limited by Powerwall to 600 V DC. 16 Maximum Disconnect Voltage is the maximum voltage allowed across each MCI in the open position(Rapid Shutdown Initiated). An individual MCI-2 has a voltage rating of 165V but in combination(connected in the same string)their voltage ratings are additive. RSD Module Maximum Number of Devices per String 5 Performance Control Power Line Excitation Passive State Normally Open Maximum Power Consumption 7 W Warranty 25 years Environmental Operating Temperature -40°C to 50°C -45°C to 70°C Specifications (-40°F to 122°F) (-49°F to 158°F) Storage Temperature —300C to 700C —30°C to 70°C (-22°F to 158°F) (-22°F to 158°F) Enclosure Rating NEMA 4X/IP65 Mechanical Electrical Connections MC4 Connector Specifications Housing Plastic Dimensions 125 x 150 x 22 mm 173 x 45 x 22 mm (5x6x1in) (6.8 x 1.8 x 1 in) Weight 350 g(0.77 lb) 120 g(0.26 lb) Mounting Options ZEP Home Run Clip Wire Clip M4 Screw(#10) M8 Bolt(5/16") Nail/Wood screw Compliance Certifications UL 1741 PVRSE,UL 3741, Information PVRSA(Photovoltaic Rapid Shutdown Array) RSD Initiation Method External System Shutdown Switch or Powerwall 3 Enable Switch UL 3741 PV Hazard Control (and PVRSA) Compatibility See UL 3741 Application Addendum 2024 Powerwall 3 Datasheet 6 i �r Gateway 3 Tesla Gateway 3 controls connection to the grid in a Powerwall system,automatically detecting outages and providing seamless transition to backup power. It provides energy monitoring that is used by Powerwall for solar self-consumption,time-based control,and backup operation. Performance Model Number 1841000-x1-y AC Meter +/-0.5% Specifications Nominal Grid Voltage 120/240 V AC Communication CAN Grid Configuration Split phase User Interface Tesla App Grid Frequency 60 Hz Backup Transition Automatic disconnect for Continuous Current 200 A seamless backup Rating Overcurrent 100-200 A Protection Device Service entrance rated Maximum Supply Short 22 kA with Square D or Eaton CSR,BWH,or BW,or Circuit Current Eaton main breaker Square D QOM breakers 25 kA with Eaton main breaker" Internal Panelboard 200 A IEC Protective Class Class I 8-space/16 circuit breakers Eaton BR,Siemens QP,or Overvoltage Category Category IV Square D HOM breakers rated to 10-125A "Only Eaton CSR or BWH main breakers are 25 kA rated. Warranty 10 years Environmental Operating Temperature —20°C to 50°C(-4°F to 122°F) Specifications Operating Humidity(RH) Up to 100%,condensing Maximum Elevation 3000 m(9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 311 Compliance Certifications UL 67,UL 869A,UL 916,UL 1741 PCS, Information CSA 22.2107.1,CSA 22.2 29 Emissions FCC Part 15,Class B,ICES 003 Mechanical Dimensions 660 x 411 x 149 mm Specifications (26 x 16 x 6 in) Weight 16.3 kg(36lb) T S 6 L_ R Mounting options Wall mount 660 mm 411 mm �1mm 2024 Powerwall 3 Datasheet I I 7 Backup Switch The Tesla Backup Switch controls connection to the grid in a Powerwall system,and can be easily installed behind the utility meter or in a standalone meter panel downstream of the utility meter. The Backup Switch automatically detects grid outages,providing a seamless transition to backup power. It communicates directly with Powerwall,allowing home energy usage monitoring from any mobile device with the Tesla app. Performance Model Number 1624171-xx-y Specifications Continuous Load Rating 200 A,120/240 V split phase Maximum Supply Short Circuit Current 22 kA with breaker18 Communication CAN AC Meter +/-0.5% Expected Service Life 21 years Warranty 10 years 'B Breaker maximum supply short circuit current rating must be equal to or greater than the available fault current. Environmental Operating Temperature —40°C to 50°C(-40°F to 122°F) Specifications Storage Temperature —400C to 850C(-40°F to 185°F) Enclosure Rating NEMA 311 Pollution Rating PD3 Compliance Safety Standards USA:UL 414,UL 414 SB,UL 2735,UL 916,CA Prop 65 Information Emissions FCC Part 15,Class B,ICES 003 Mechanical Dimensions 176 x 205 x 74 mm(6.9 x 8.1 x 2.9 in) Specifications Weight 2.8lb Meter and Socket Compatibility ANSI Type 2S,ringless or ring type External Service Interface Contactor manual override19 Reset button Conduit Compatibility 1/2-inch NPT 9 Manually overrides the contactor position during a service event. ---176 mm 4 4OOP 205 mm 0 74 mm 2024 Powerwall 3 Datasheet 8 Backup Gateway 2 Backup Gateway 2 controls connection to the grid when paired with Powerwall 3,automatically detecting outages and providing seamless transition to backup power. Backup Gateway 2 also provides energy metering for solar self-consumption,time-based control,and backup operation. In this system configuration,Powerwall 3 acts as the Site Controller,with the Backup Gateway 2 Site Controller disabled. Performance Model Number 1232100-xx-y Internal Primary +/-0.2% Specifications AC Voltage(Nominal) 120/240 V AC Meter Internal Auxiliary +/-2% Feed-in Type Split phase AC Meter Grid Frequency 60 Hz Backup Transition Automatic disconnect for Current Rating 200 A seamless backup Maximum Supply Short 10 kA20 Modularity Supports up to 10 AC- Circuit Current coupled Powerwalls Overcurrent Protection 100-200 A,Service Optional Internal 200 A 6-space/12 circuit Device entrance rated Panelboard breakers Siemens QP or Square D Overvoltage Category Category IV HOM breakers rated 10- 80A or Eaton BR breakers rated 10-125A 20 When protected by Class J fuses,Backup Gateway 2 is suitable for use in circuits capable of delivering not more Warranty 10 years than 22kA symmetrical amperes. Environmental Operating Temperature —20°C to 50°C(-4°F to 122°F) Specifications Operating Humidity(RH) Up to 100%,condensing Maximum Elevation 3000 m(9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 311 Compliance Certifications UL 67,UL 869A,UL 916,UL 1741 PCS, Information CSA 22.2 0.19,CSA 22.2 205 Emissions FCC Part 15,Class B,ICES 003 Mechanical Dimensions 660 x 411 x 149 mm �--4111 mm� 149 Specifications (26 x 16 x 6 in) mm Weight 20.4 kg(45 lb) Mounting options Wall mount, Semi-flush mount T = s L F i i 660 mm tin I I I 2024 Powerwall 3 Datasheet 9 Powerwall 3 Example System Configurations Powerwall 3 with Gateway 3 (Optional— Whole Home Backup I � I 9 I I I Solar I ® Meter Grid Meter socket panel Gateway 3 Load center I Backup loads Powerwall 3 Powerwall 3 with Backup Switch (optrona/— Whole Home Backup I ` ► i I I i I Backup Switch I I Solar I Meter Grid Meter socket panel Load center I Backup loads Powerwall 3 Powerwall 3 with Backup Gateway 2 roptoRa,- Partial Home Backup I % i I�� I I � I Utility Meter I I Solar _I Main Breaker == Grid Meter load center Backup Gateway 2 Load center I I Non-essential loads Backup loads Powerwall 3 2024 Powerwall 3 Datasheet 10 Powerwall 3 Example System Configurations Powerwall 3 with Gateway 3 (1)Powerwall 3 with(3)Expansion Units Solar ® Meter Grid Meter socket panel Gateway 3 Load center I Backup loads Powerwall 3 Powerwall 3 Expansion 4 4 Powerwall3 Powerwall3 Expansion Expansion Powerwall 3 with Backup Switch (4)Powerwall 3 Units with(3)Expansion Units(Maximum System Size) Backup Switch Solar Solar Solar Solar F11i T Meter 4 4 4 4 Grid Meter socket panel Load center Generation panel I Backup loads Powerwall 3 Powerwall 3 Powerwall 3 Powerwall 3 4 4 4 • • . . ,J Powerwall3 Powerwall3 Powerwall3 Expansion Expansion Expansion 2024 Powerwall 3 Datasheet 11 TY PLAN KEY fP] ERIICE DISCONNECT 'Q° -SERVICE DISCONNECT DRIVEWAY IS 4'-11"AWAY FROM THE PROPOSED PV1-0 COVER SHEET Q-SUPPLY SIDE CONNECTICN ESS EQUIPMENT LOCATION ���p O �TACAM A1-3 ESS EQUIP.LAYOUT PLAN _-AUTOMATIC TRANSFER SWITCH APPROVED AS NOTED i YSTURA�G ES1STEM A2-6 ESS ELEVATION Q-GAS METER s (EXT) a_„• DATE• r� B.P.# -ram �"I Pw 0-SUB PA iQ E1-1 ONE-LINE DIAGRAM ®- RVGEPANEL NEL �••it SUNATION SOLAR SYSTEMS NYSERDA E2-1 PV LABELS -INVERTER FEE 0V'4V BY Bi 171 REMINGTON BOULEVARD INSTALLER 4355 E2-2 ESS LABEL ©, _ENPHASEIOCOMBINER NOTIFY BUILDING DEPARTMENT AT\ RONKONKOMA,NEW YORK 1177i NUMBER 61-2 ESS PHOTOS E_PANEL PHOTOVOLTAIC 631-765-1802 8AM TO 4PM FOR THE ' -ELECTRIC VEHICLE CHARGER FOLLOWING INSPECTIONS: ❑ } Waslo Residence Q � � 540 Longview Lane, Southold, NY 11971 �j-ENPHASE ENVOY 1. FOUNDATION-TWO REQUIRED Q-SENSECONSUMPTIONMONITOR FOR POURED CONCRETE 0-AC DISCONNECT o Draw,n By: M. Danziger- 09/18/2025 p, -'VpSPECn0N REQUIRED 2. ROUGH-FRAMING&PLUMBING -PSEG COGEN DISCONNECT 3• INSULATION IL ________-._____ _-._..________ ._---_ -T-TESLA GATEWAY 4. FINAL-CONSTRUCTION MUST ®-TESLAPOWERWALL , BE COMPLETE FOR C.O. RETAIN STORM WATER RUNOFF m'ENPHASEIOSVSTEMCONTROLLER ALL CONSTRUCTION SHALL ME R-ENPHASE 105P BATTERY i � 5 uj PURSUANT TO CHAPTER 236 GENERATION PANEL REQUIREMENTS OF THECODS-bF R :,�:•t� Z_. OF THE TOWN CODE. M-BACKEDUPLOADSCENTER YORK STATE. NOT RESPONSIBLE FOR _ 4 O -VENTPIPE DESIGN OR CONSTR RS oA` Z V ••'-EXTERIOR LOCATION O 0 .. _1ST FLOOR LOCATION .. .. ..� .. ..... .. ......�...... a' _ LL -BASEMENT LOCATION COMPLY WITH ALL CODES ^• -GARAGE LOCATION NEW YORK Building Review,Note AS e STATE&TOWN DES Town building examiner has received the enclosed document for minimum acceptable REQUIRE plan submittal requirements of the town as specified in the building and/or Residential El Code of the State of New York. This review does not guarantee compliance with that code. that responsibility is guaranteed under the seal and signature of the New York State licensed design professional of record. That seal and signature has been EXISTING PV SYSTEM SOUtWTOWN PONIN OW interpreted as an attestation that,to the best of the licensee's belief and information the work in this document is: Module Type/Qty: (23)REC420AAPureR Accurate MOWTOWNTI�S Conforms with governing codes applicable at the time of submission Module Dimension: 68.1"x 44"x 1.2" -N.Y . Conforms with reasonable standards of practice and with view to the safeguarding of life,health,property and public welfare is the responsibility of the Module Weight/PSF: 47.4 Ibs/2.27775108121096 PSF �I Runv n up�l t licensee. Y�171/W HI V Micro Inverter: (23)Enphase IQ7X-96-2-US c^ VV� k Structural Statement � System DC Rating: 9.66 kW .�' 3 49TING r>11*31 > • The existing structure is adequate to support the new loads imposed b the P Y System AC Rating: 7.2312 kW/AC ) o photovoltaic modules stem including uplift and shear. The existingrafter sizes Y y: 0 C C U PAN r and dimensions conform to RC-NYS 2020 table R802.4.1(2)-Raftr Spans. Installed by: SUNation Solar Systems LE ~.,_,a ,� -,—� -,, _ �, USE IS UNLAWFUL T PV Notes PROPOSED ENERGY STORAGE SYSTEM 1. This PV system has been designed to meet all current and applicable fire WITHOUT C E RTI FI CAT prevention setback pathways per 2020 NYS Residential Code. Proper ground Battery Model: (1)Tesla Powerwall 3 clearance,roof access points,access pathways and ventilation systems shall be �y provided where necessary. An in depth description of each applicable code Microgrid Interconnection Device: (1)Gateway 3 OF 1 _UPAN.r f Y'� _ESE- 'VED FOR A i". ! reference and exception for any codes is depicted on the PV-1 plate of this VV V dJ drawing package. Total Energy(kWh)Each ESS Unit: 14 kW 2. Roof shall have no more than a single layer of roof covering in addition to the solar equipment. Usable Energy(kWh)Each ESS Unit: 13.5 kW 3. Installation of solar equipment shall be flush-mounted,parallel to and no more than 6-inches above the surface of the roof. Total Energy(kWh)ESS Total: 14 kWh N 4. Weight of the installed system shall not exceed more than 5-psf 5. Any plumbing vents are not to be cut or covered for solar equipment installation. Usable Energy(kWh)ESS Total: 13.5 kWh ! Any relocation or modification of the vent requires a plumbing permit and FULL HOUSE ROOF PLAN I inspection. SCALE:N.T.S. i This PV system has been designed to meet the minimum design standard for building and other structures of the ASCE 7-16 and the 2020 New York State Residential Code. Energy Storage System Notes PVImO 1. This energy storage system(ESS)has been designed to meet all current and applicable design parameters set forth by the 2020 residential code of New York JOB## 9 94 2 5 6 State. An in depth description of each applicable code reference and exception for any codes is depicted on the A1-3 plate of this drawing package. COVER PAGE 2. Per the NYSERDA rebate program,the proposed energy storage system shall be installed and configured for backup only,meaning that only during a loss of grid w REVISION # N/A 3. The proposed ESS ower will the ESS shall be rn on lntte connected power the to antexistng PV syn the stem installed& permitted�~ S U�O \T I®� the physical layout of the either tion or PV system. contractor. No changes shall be made to t - _ (;�^L I, h. REVISED BY N/A This ESS has been designed to meet the minimum design standards for building as described within the 2020 New York State residential code. ENERGY STORAGE SYSTEMS waa FISO '�r (NY)R327.1 General. Energy storage systems installed in buildings or p structures that are subject to the provisions of this code shall be b - }. =z installed and maintained in accordance with Sections R327.2 through DRIVEWAY IS 4'-11"AWAY FROM THE PROPOSED � �' z ESS EQUIPMENT LOCATION R327.11. The temporary use of an owner's or occupant's electric — powered vehicle as an energy storage system shall be in accordance r PROPOSED TESLA POWERWALL with Section R327.12. nay U 4'_11" PROPOSED ENPHASE IQ COMBINER S' q Energy storage system installations exceeding the permitted PROPOSED SERVICE DISCONNECT F£55 aggregate ratings in Section R327.5 shall be installed in accordance UTILITY METER with Section 1206.2 through 1206.17.7.7 of the Fire Code of New York MAIN SERVICE PANEL State. v PROPOSED TESLA GATEWAY PROPOSED RAPID SHUTDOWN SWITCH [NY] R327.3 Installation. Energy storage systems shall be installed in accordance with the manufacturer's instructions and their listing. HI Q HI [NY] R327.3.1 Spacing. Individual units shall be separated from each � ENERGY ON other by at least 3 feet (914 mm) of spacing unless smaller 0 QD RAY separation distances are documented to be adequate based on O SUNation Solar Systems large-scale fire testing complying with Section 1206.6 of the Fire Code ~ 171 Remington Blvd. of New York State. W Ronkonkoma,New York 11779 W (631)-750-9454 of [NY] R327.4 Location. Energy storage systems shall only be installed U) in the following locations. % Z NSTANYSERLLL R A 3 5 5 DA 1. Detached garages and detached accessory structures. NUMBER 2. Attached garages separated from the dwelling unit living LL space and sleeping units in accordance with Section ❑ F-1 I JOB NUMBER R302 of this code. W 3. Outdoors on exterior walls located a minimum 3 feet 994256 (914 mm).from doors and windows. 4. Utility closets and storage or utility spaces within IL dwelling units and sleeping units ❑ O z O [NY] R327.5 Energy ratings. Individual energy storage system units LL shall have a maximum rating of 20 kWh.The aggregate rating shall not exceed: 1. 40 kWh within utility closets and storage or utility = N spaces. 0 z Co 2. 80 kWh in attached or detached garages and detached CD M M accessory structures. Q = o 3. 80 kWh on exterior walls. o 4. 80 kWh outdoors on the ground. p � N ILL [NY] R327.6 Electrical installation. Energy storage systems shall be Z m c UJI installed in accordance with NFPA 70. Inverters shall be listed and labeled in accordance with UL 1741 or provided cq m m as part of the UL 9540 listing. Systems connected to the utility grid o 3 shall use inverters listed for utility interaction. o 0 v u') [NY] R327.7 Fire detection. Rooms and areas in which energy storage systems are installed shall be protected by smoke alarms in ' ' - accordance with Section R314. A heat detector or heat alarm listed and interconnected to the smoke alarms shall be installed in locations where smoke alarms cannot be installed based on their listing. (23) EXISTING O PV MODULES [NY] R327.8 Fire-resistance rating. Rooms and areas containing energy storage systems shall be protected on the system side by no nI less than 5/8-inch Type X gypsum board or equivalent, installed on the walls and ceiling of the room or area. Attached garages containing energy storage system shall be protected on the system side by N.T.S. fire-resistant construction in accordance with Section R302. [NY] R327.9 Protection from impact. Energy storage systems installed Al 3 in a location subject to vehicle damage shall be protected by approved ESS EQUIPMENT barriers. LAYOUT PLAN r1E6N y0 Oa�C, F/SA,yF t CO Ze 3 z � r r 11 v ys� . 0 6 O�Pv FEgS � SUNNTION -3Y SUNation Solar Systems 171 Remington Blvd. Ronkonkoma,New York 11779 (631)-750-9454 IN SSTAALLELLE R4355_ N NUMBER JOB NUMBER ESS KEEPOUT 994256 R 327.4 :z z_: 0') Ln • -- � N BATTERY SHUTOFF CD SWITCH z co - RELOCATE ENPHASE / IQ COMBINER .=J / CD 0 Q) O PSEG ISOLATION SWITCH(200A) F 0) L a � o PSEG METER cn 0) LL ? O ❑ M W J cl-i > m 2,_y, v) -- : c 0 3 O (1)PROPOSED TESLA LC) DISTANCE FROM NORTH EXTERIOR POWERWALL 3 WALL TO CURB OF DRIVEWAY. THIS LOC4MON IS EQUIPMENT 18"OFF GRADE TO OUTSIDE OF THE VEHICLE PATH OF TRAVEL PREVENT SNOW BUILDUP BELOW - ESS EQUIPMENT 3/8" = 1'-0" A2=6 ESS ELEVATION ,;Etry Yp L ENPHASE GATEWAY 4/01 F1,3 —-f i (No loads.monitoring only) Al T 'Q 120/240v Utility Service 3 t\.'t1 Z f\ BLANK Gatewa ,I f\ y Existing PSEG Utility Meter t1 BLANK Account#-9630743102 _i Meter#-BDBD5279 I\1 I S EXISTING ENPHASE BRANCH CIRCUIT#1 21120A 120/240V Circuit#3 I EXISTING ENPHASE BRANCH CIRCUIT#2 0 ` Clcu20#4 EGC T i r. '�' 'i Serrvvice rated manual disconnect isolates ESS from utility G ; per section 7.2[PSEG s SGIP] EXISTING ENPHASE Enphase A/C Branch Circuit(typ.) IQ COMBINER 4C ROOF ATTIC EXTERIOR .4i Enphase Microinverter(typ.) G Service 8 SUNATI®N Disconnect COMBINER EXTERIOR `I,) G f Module J-Box(typ.)-- PANEL DISCONNECTING MEANS �' SUNation Solar Systems PV STOP SWITCH NC 171 Remington Blvd. Ronkonkoma,New York 11779 . . . (INITIATES RAPID SHUTDOWN FOR INVERTERS) j F_TLOCATED:LEFT OF INVERTERS - Factory Installed (631)-750-9454 PV Module READILY AVAILABLE 2P40A (typ) Panelboard Kit i PV Cenfti red for 200A NYSERDA ods 2ERAVJG comet Pe i MAIN INSTALLER 4355 EGC Attached To Rail(typ.) TGER comets wire Powerwall NUMBER I PROPOSED �,— TESLA POWERWALL 3 ( 200A s _ JOB NUMBER CONDUIT AND CONDUCTOR SCHEDULE MODEL-1707000-xx-y ---/� — i s MAIN TAG CONDUCTOR CONDUIT RUN 13.5kW BATTERY WITH INTEGRATED DC INVERTER 994256 TYPE GAUGE QUANTITY TYPE SIZE LENGTH 120/240 VAC,1-PHASE s MAX 48AMP INVERTER BATTERY 1 Enphase Q-Cable 12 4 N/A N/A 15' r 2 Type NM 10 4 NIA N/A 20' (ESTOP — Automatic 3 THWN-2 10 4 PVC SCH.80 1.25" 25' Relay _ EGC 10 1 PVC SCH.80 1.25" 25' 4 THWN-2 8 3 PVC SCH.80 1.001, 5' • • Backup EGC 10 1 PVC SCH.80 1.001, 1 5' r DC AC INPUT/ TC-ER- VN a. � Lugs C°nne°ts t,t°Terla Asset 5 THWN-2 6 3 PVC SCH. 80 1.25" 15' INPUTS OUTPUT ConimlleronPowornall3 ° � L MAw � N .1-13 6 EGC 10 1 PVC SCH. 80 1.001, 15' C, TC-ER-ContmlNfire. COMMSSERVICE r- N Gateway 3 7 THWN-2 3 3 PVC SCH. 80 1.50" 10' mm.nn� / PANEL 00 ane P°" \7; Z CO on Tesla Gateway] GEC 8 1 PVC SCH. 80 1.50" 10, T���oe i�\ 0) 8 THWN-2 3 3 PVC SCH. 80 1.50" 10' / G Z N 6 O � � TELSA BACKUP 0 U O ~ i GEC 8 1 PVC SCH. 80 1.50" 10' \ GATEWAY 3 Q � � 4'I O 0 r/� LL 6� o C Circuit# PV Module Qty. Micro-Inverter Qty. Maximum AC Operating Current — W cn M 1 EXISTING REC420AAPureR 12 Enphase WX-96-2-US 12 15.72 A GROIUNDING v) ELECTRODE m 2 EXISTING REC420AAPureR 11 Enphase WX-96-2-US 11 14.41 A c J � O 11, LO Maximum AC Operating Current(Total) 30.13 A E1 =1A ONE-LINE DIAGRAM ttEWAIG AC YpR • • • s • LABEL LOCATION: LABEL LOCATION: ��O,x G F/ghF�• MAXIMUM AC OPERATING CURRENT SOURCE CIRCUITS: 1 AT EACH AC DISCONNECT,COMPLETE VOLTAGE AND — — • — MAIN DISCONNECT PANEL: 1 AT EACH AND AT BUILDING MAIN SERVICE � NOMINAL AC OPERATING CURRENT CURRENT VALUES ON DISCONNECT LABEL. DISCONNECT IF APPLICABLE. 3 ? of r NEC 2017 690.54/NEC 2017 690.13(B) NEC 2017 705.10Sec `C► �ysF o e o��v • . Disconnect FEgS EDK 11 rocated next to MeterPan DisconnectService ELECTRIC SHOCK HAZARD of NOTE.ATTENTION STICKER GETS PLACED ON UTILITY METER IN ADDITION TO DO NOT TOUCH TERMINALS THE BUILDING MAIN SERVICE DISCONNECT TERMINALS ON BOTH THE LINE AND Primary Service Disconnect LOAD SIDES MAY BE ENERGIZED rhisbuilding is equipped with an IN THE OPEN POSITION Located in Main Service Panel ted Electric Power SUNNTION ction Source ENERGY PHOTovoLTAlc moDULEs PRODUCE DC VOLTAGE wi-ie+,ER THEY AREea-om rosuNucHr • r SUNation Solar Systems Source Type: 171 Remington Blvd. Solar Photovoltaic Ronkonkoma,New York 11779 (631)-750-9454 LABEL LOCATION: Disconnect is Located: Intenor: Basement: Garage:_ Exterior: S COGEN IN ALLE 3 5 5 • — 1 AT DER Disconnect Switch/Isolator Front Rear LH sideSTALLER PSEG SGIP Chapter 7-7.2 DER Isolation Switch/Isolation RH side:__ Other Location: NUMBER Switch sUNation solar systems SOLAR SYSTEM EQUIPPED JOB NUMBER 631-750-9454 www.sunation.com WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN 994256 SWITCH TO THE PHOTOVOLTAJC "OFF'POSITION TO w. ' SHUTDOWN PV SYSTEM EQUIPPEDAND REDUCE THE SHOCK HAZARD SHUTDOWN IN ARRAY ti O) LSD � N �— O N Z 00 Z O L) o 0 o 0 0 LM l N Ii N c0 Z o c ca N � > m O —j c� O I E2= 1 PV LABELS LABEL LOCATION: LABEL LOCATION: �4.. ANEWFIS y�R CAUTION CAUTION TRI-POWER SOURCE1 AT MAIN SERVICE DISCONNECT,M.I.D.,AND UTILITY METER DO NOT ADD •.• 1 AT MAIN SERVICE PANEL(IF WHOLE HOME BACKUP)-OR-AT BACK UP LOADS SECOND SOURCE IS A PHOTOVOLTAICCENTER. # THIRD SOURCE IS AN ENERGY STOR SYSTEr NEC 2017 705.12(13)(3) r NEC 2017 408.4/NEC 220 �O inys� ' 0 4 O�Qv ' F 5 LABEL LOCATION- LOCATED INDOORS 1 AT MID-REFERENCE ONLY ff?TWM• - • • LABEL LOCATION: LOCATED ON OPPOSITE WALL PCS Controlled Current Setting: 1 AT EACH PCS-CONTROLLED PANEL WITHIN The rpaximurn • - . • THE CONTROLLED SYSTEM[IF APPLICABLE] ♦�SUNNTION mpin panel is controlled electronically. to theNEC 2020 705.13LOCATED ON ADJACENT WAL L Manufacturer's instructions for more information. \` SUNation Solar Systems 171 Remington Blvd. Ronkonkoma,New York 11779 (631)-750-9454 •" • LABEL LOCATION: S 4355 I INSTALLER - IN NING 1 AT EACH CURRENT TRANSFORMER ASSOCIATED WITH THE ENERGY NUMBER MANAGEMENT SYSTEM[IF APPLICABLE] JOB NUMBER i THIS SENSOR IS PART OF 994256 , POWER CONTROL SYSTEM. DO LABEL LOCATION: NOT REMOVE. REPLACE ONLY ARNING1 AT MAIN SERVICE DISCONNECT AND M.I.D. WITH SAME TYPE AND RATING THE EQUIPMENT FED BY NEC 2017 705.12(13)(3)(c) MULTIPLE SOURCES. TOTAL RATING OF ALL OVER CURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY N OFBUSBAR o } CV Z co LABEL LOCATION: (D -a � Z CD COGEN Disconnect 1 AT DER Disconnect Switch/Isolator i PSEG SGIP Chapter 7-7.2 DER Isolation Switch/Isolation Q Switch 0 a) (/) 11 O (If ai co o co r Lu U) F- co m c o J f>3 O i V L0 E2m2 ESS LABELS FWV , p 0A S y �! SUNNTION r SUNation Solar Systems 171 Remington Blvd. Ronkonkoma,New York 11779 (631)-750-9454 N SSTALLE I ALLE R 435 5 N NUMBER JOB NUMBER - r 994256 ARRAY LOCATION(S) EXISTING SOLAR SATELLITE IMAGE - VIA GROUND EQUIPMENT LOCATION 00 O N s }�. ; • y rwnsr Z O "a O O U O O — Ix N U) N i a C o ! 'L e Lu cu ..._. >+ r -- J f0 O 0 r y V � Y PROPOSED ENERGY EXISTING UTILITY EXISTING MAIN SERVICE STORAGE LOCATION METER PANEL G1 =2 ESS PHOTOS