Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
52477-Z
of Solo/ o Town of Southold * * P.O. Box 1179 a� 53095 Main Rd o�r�ouNTI.a Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46856 Date: 02/13/2026 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 265 Orchard Ln Southold, NY 11971 Sec/Block/Lot: 89.-2-5.1 Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 10/29/2025 Pursuant to which Building Permit No. 52477 and dated: 11/19/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Additional roof-mounted solar panels to an existing system on a single-family dwelling as applied for. The certificate is issued to: George Coritsidis ,Debra Coritsidis Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 115595 01/13/2026 PLUMBERS CERTIFICATION: 6utho(A- ed Signa ire �aofsoU,yo TOWN OF SOUTHOLD BUILDING DEPARTMENT `� • �� SOUTHOLD, NY "Vkl BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52477 Date: 11/19/2025 Permission is hereby granted to: George N Coritsidis 1800 Cedar Beach Rd Southold, NY 11971 To: install additional roof-mounted solar panels to an existing system on a single-family dwelling as applied for with flood permit. Premises Located at: 265 Orchard Ln, Southold, NY 11971 SCTIVI#89.-2-5.1 Pursuant to application dated 10/29/2025 and approved by the Building Inspector. To expire on 11/19/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 CO-RESIDENTIAL $100.00 Flood Permit $150.00 Total $350.00 ------------------------------ Building Inspector r ,_ 11 NASSAU ELECTRICAL ;. FEB 1 2 2026 SIIIEOLK INSPECTORS 159 Route 25A, Building 1 Suite B 'Ir Miller Place, NY 11764 Telephone:631 495 8136 - Fax:631 509 4538 • E-Mail:Requests@SuffolkBEI.com CERTIFICATE OF ELECTRICAL COMPLIANCE Applicant: Element Energy LLC Certificate No.: 115595 Rough In Inspection Date: Final Inspection Date: Jan 13,2026 Application No.: 9631037402 Building Permit No.: 52477 County Tax Map No.: 1000 089.00 02.00 0a3-00 rJ + (1 LIPA Solar App No.: PAM-2025-393910, This Certificate of Electrical Compliance is limited to the inspection and compliance of electrical equipment and/or work described below,installed on behalf of the applicant named above,located at the premise of and not after the final inspection date above: Owner: DEBRA CORITSIDIS Site Location: 1800 CEDAR BEACH ROAD,SOUTHOLD,NY 11971 Owner's Address(if different): 0 Residential 0 Indoor ❑Basement ❑Service ❑Shed ❑Commercial 0 Outdoor ❑First Floor ❑Pool ❑Hottub ❑New ❑Renovation ❑Second Floor ❑Attic ❑Garage ❑Addition ❑Survey 0 PV Solar ❑Generator ❑Conversion - - - ; ❑Signs ❑Battery Storage ❑Safety Inspection Other: INVENTORY Single Phase Heat Duplex Recpt 0 Ceiling Fixture 0 Dual Func Breaker Three Phase Hot Water GFCI Recpt Wall Fixture Smoke Main Panel AC Cond Single Recpt Recessed Fixture CO Detect Sub Panel AC Blower Range Recpt LED Lighting Smoke CO Combo — Transformer Appliance Ckt Dryer Recpt Emergency Time Clock Disconnect Switches Twist Lock Exit Fixtures Pumps GFCI Breaker Heat Pump Electric Heat 0 Pool Luminaire 0 Exhaust Fan 0 Other Equipment:System Size:9.46 kW Qty:22 Desc:EAGLE JINKO JKM430N-54HL4-B City:22 Desc:Enphase IQ8MC-72-M-US The electrical work and/or equipment described above were inspected and was found to be in compliance with local, state and national electrical code requirements and this office. Applicant: Element Energy LLC License No.: 52689-ME Date Printed: Jan 13,2026 Inspected By: Joe Coppola Signature: SOUTyO # . # TOWN OF SOUTHOLD BUILDING DEPT. coum��'' 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ a/FINAL SOIAlie-, [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: jq6l S ( Cte. i c4 o-k 1-4-41°2, �h�.- arm �2 �.a• DATE INSPECTOR WO 76yVm/th Meadowbrook Drive Scott E PE *�x/«t L/T840O4 ".x""" v+ Hoath .( Pf� F!Eno �^ � ' ��A 1 � �O�� | �'' o/��a [28Y B7�-3483 _,-_' ~ �, . ^" ' - �~^~ ^_ ' . ' Gregory TBveatad, PE m0malingconuultin000m Element Energy LLC 747O Sound Avenue, yNattituch. NY, 11952 Re: Engineering Services (Post-install) Coribsidis Residence 18OO Cedar Beach Road, Southold, NY 9.460 kVVSystem To Whom |t May Concern: Pursuant to your request, we have reviewed the installation of the above-referenced solar panel system. As you are aware, this office initially prepared a structural assessment, dated October 27, 2025, of the solar panel installation. This installation was inspected and found to be in compliance with the layout plan as specified in our report, product installation criteria, and the requirements of the current building code. We have determined that the equipment will not create a negative impact on the building's structural design, including any additional loads imposed (dead, snow, wind). This letter pertains only to the panel support attachments to the roof framing and not the engineered photovoltaic panel pnoducto, componento, or electrical-related installations/connections. Should you have any questions regarding the above or if you require additional information do not hesitate to contact ma. v ro �LA, � w~ Scott E. VVysai PE New York LioenoaN New York C�OANo. D 571 I'tiwomoutonncfu`v law mvonypemonn.vnLeoo acting under the direction ofmUneuoag N professional,tmottermn1hom/io any way.IT'an item 6mo,|ngthe-oomiommU.consedprofessional isoItered the ottornQ.uowuoo6 professional.nhoA aMixto their item thm|roeaiond the notation 76 N. Mmadowbrmok Drive,Alpine UT "altered by'8o0wwed-bv their 8 igmm,tun,and tbm New York C6A#0' 022571 -date mfauvhubevmdon ondm'np�o�� ' Signed209/2O2S u ��*nw1puono,���m �\�n. Expires 7/31/2027 FIELD INSPECTION REPORT DATE COMMENTS rn FOUNDATION (1ST) — --- --- - -- ------ :� ----------------------------------- FOUNDATION (2ND) -- �O cn ROUGH FRAMING& PLUMBING INSULATION PER N.Y. - STATE ENERGY CODE — -- FINAL ADDITIONAL COMMENTS A. rn _ - - -- X _ x TOWN -OF SOUS IHOLD —BL11LD- n\j(G DEPARTMENT Toyvn Hall Annex 54 75 Main Road P. 0. Box 1179 Southold. NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 Cate Received APPLICATION FOR BUILDING PERMIT Far Office Use Only I �� PERMIT INO. Building Inspector: OCT 2 9 2025 ! F i I Applications and forms must be filled out in their entirety.Incomplete applications w Wh ill not accepted. eirethe App nt lica js,770t the n -nt Owuney's Authorizatiotn-JvFmL Page 27J)shafl'be con,plete Date: ro—ImER- �S)OF PROPERTY�- I I - 1 1 Name: -D& +S) IS SCTM# 1000 (1,1 I f 00 2 .0b Project Address: L--&4_ a0z 4 1 1 F-7—C-4 LA4 h p I d �J-Lf, I q q Phone -7, Ernail: Mailing Address: 1900 Cad&r xi-cA o q[11 CONTACTPIERSOP4- Name: L,,o Mailing Address: -7 4 vq Vy Phone#: L Iq 5 Em-7, 0LJ Pprnl,�,4-s e- Z2 Gh PROFESS-10911AIL JNFOR-PRATIOM- -J Name: Mailing Address: Phone#- a Email: COT RAC TOR 1NFC9M?ATWR-, Name: Mailing Address: V t) k44 JA C Phone#: 62) � - 39 Email: DESCMPTION OF PROPOSED CON5TR.UCn10H co 0) ONewStructure OAddition DAlteration EIRepair ODemolition Estimated Cost of Project: 'E5iQther In64-iid Stdo-q- PV 6!�z,+,-n q,q -3 a$ 5 q co� Will the lot be re-graded? E]Yes;gNo Will excess fill be removed from premises? OYes)—geNo PROPERTY INFORMATION Existing use of property: �s Intended use of property: ZoRr use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes>Vo IF YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professional Is responsible for all drainage and stonn water issues as provided by Cha ter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,Newyork and other applicable laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are Pun as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): Lorraine Di Penta BAuthorized Agent El Owner Signature of Applican to P Date: IN 1 STATE OF NEW YORK) /lam/ SS: COUNTY OF Suffolk Lorraine DiPenta (Name of individual signing contract)above named, being duly sworn, deposes and says that(s)he is the applicant (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this � day of �G �D1✓e--l20Z otal ublic PROPERTY OWNER AUTHORIZATION' : LOUIS i ROMEO Rotiiry Public,State of New York (Where the applicant is not the owner) No.o1R06314813 n Suffolk 6�1 Commission IExp es November County,20A CO ' ��i S residing at do hereby authorize Lbrr&/OezM � o apply on my ehalf to the Town of Southold BuildingDepartment for Chevy y L L�- p approval as described herein. C', C, )� / C)/& 1,2, Owner's Signature Date Qr/�/k��(I," Print Owner's Name 2 TOWN OF SOUTHOLD—BUILDING DEPARTMENT ' !-,", Town Hall Annex 54375 Mai'n Road P. O. Box 1179 Southold, NY I I 9 '1�,0959 T Telephone (631) 765-1802 https://www.southoldtownny.gov NOV 2 1 2025 Flood plain Development Permit Application"" PROPERTY INFORMATION: I Flood Zone: FIRM Panel: SCTM#1000- Address: , L, 5 o r ch(L roQ L�YLP_, (S o LL�hb 97 1 City: 'So�k () [A- , � zip: I 1 9 CONTACT PERSON: Name: �o rra--4;1leJ 1—,)) I Phone#: -7 DLI Mailing Address: L/-7 AJ 4 //PROJECT DESCRIPTION: ( 1)C.,6 Y-0. Co r1'+5)CI'l-s' SECTION A:STRUCTURAL DEVELOPMENT(CHECK ALLTHAT APPLY) Type of Structure Type of Structural Activity sidential 0 to 4 families) El New structure 0 Residential(more than 4 families) El Demolition of existing structure El Combined use 0 Replacement of existing structure 0 Non-residential El Relocation of existing structure El Elevated El Addition to existing structure El Flood proofed(attach certification) 0 Alteration to existing structure E] Manufactured Home Other: Q5 D -0L(._S r6 C) P90i,,jLk/( 0 Located on individual lot El Located in manufactured home park SECTION B:OTHER DEVELOPMENT(CHECK ALL THAT APPLY) El Clearing of trees,vegetation or debris 0 Mining 0 Grading El Drilling El Dredging El Connection to public utilities or services D Paving El Placement of fill material El Drainage improvement(including culvert work) El Roadway or bridge construction El Fence or wall construction El Watercourse alteration (attach description) 0 Excavation (not related to a structured development) 0 Other development not listed (specify): By signing below I agree to the terms and conditions of this permit and certify to the best of my knowledge the information contained in this application is true and accurate. I understand that no work may start until a permit is issued.The permit may be revoked if any false statements are made herein.If revoked,all work must cease until permit is re-issued. Development shall not be used or occupied until a Cert.of Compliance is issued.The permit will expire if no work is commenced within one year of issuance.Other permits may be required to fulfill regulatory requirements.Applicant gives consent to local authority or representative to make reasonable inspections to verify compliance. Application Submitted By(print name): Signature of Applicant: Date: APP A� BY' ED AS NOTED DATB.P.# FEE NOTIFY BUILDING DEPARTMENT AT 631-765-1602 BAM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONIC.RETE 2. ROUGH-FRAMING&PL:Ic V`V '1G 3. INSULATION 4. FINAL-CONSTRUCTION MUST ELECTRICAL BE COMPLETE FOR C.O. INSPECTION REQUIRED ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTON ERRORS COMPLY WITH ALL CODES OF NEW YORK STATE &TOWN CODES AS REQUIRED AND CO DITIONS OF FLOOD ZONE4ILL.- PTERSOUTHOLD WN ZBA COSOUTHO OWN PLANNING BOARD MPLY WITH CHA "46" FLOOD DAMA(*PAEVENTION .•.......�,_____..SOUTHO TOWN TRUSTEES SOUTHOLD TOWN CODE. ...,..r..._._..�NXS. C $O OLD HPC SCH OCCUPANc� OR USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY WSSLING NSULTMG 76 North Meadowbrook Drive Scott E. Wyssling, PE 4 Alpine, UT 84004 Heath J. Harpster, PE, P.Eng office(201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com October 27, 2025 Element Energy LLC 7470 Sound Avenue, Mattituck, NY, 11952 Re: Engineering Services Coritsidis Residence 1800 Cedar Beach Road, Southold, NY aka. r265 9.460 kW System D trc�a To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: Assumed 2x6 dimensional lumber spaced at 16" on center. Roof Material: Composite Asphalt Shingles Roof Slope: 17& 18 degrees Attic Access: Inaccessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing =7 psf o New Solar Panels and Racking = 3 psf o TOTAL= 10 PSF • Live Load =20 psf(reducible)—0 psf at locations of solar panels • Ground Snow Load =25 psf o Wind Load based on ASCE 7-16 o Ultimate Wind Speed= 134 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2020 NYS Residential Code (2018 IRC). This analysis indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent IronRidge installation manual. If during solar panel installation,the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a#14 lag screw is 194 Ibs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on two screws with a minimum penetration depth of 2",the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using two#14 lag screws with a minimum of 2" embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of rafters, and condition of the roof, the panel supports shall be placed no greater than 48"on center. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2020 NYS Residential Code (2018 IRC), current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Ar y yours, ,� Scott E.Wyssli , PE NY PE License No. NY COA#0022571 It is a Violation of the taw far any person,unless acting underthe direction of a licensed professional,to alter an item in any way.If an ` item bear!ngthe'seaLofa licensed.professional 'is altered,the alteringlicensed professionaL she ll affizto their itenntheirseal and_tfienotation' 1� - VV� "alten d by"followed by thei r sighatu re snd the date.of"such alteration,and'a specific description of the alteration. Wyss9ing Consulting, PD_LC 76 N.Meadasvibirook Drive,A➢pine UT New York COO 90022571 Signed 10/27/2025 Expires 7/31/2027 SUG R CONTRACTOR DEB'R"Q` v(�O' `ITSIDIS ELEMENT is Ej n ENERGY BOLARI BATTERY BACKUPIE31.779.7993IE2HY9.COM AHJ UTILITY SCOPE OF WORK VICINITY MAP ELEMENT ENERGY LLC TOWN OF SOUTHOLD LONG ISLAND POWER AUTHORITY (N) 9.460F(W DC/7.040KW AC ROOF MOUNTED PV SYSTEM - 7470 SOUND AVE, (22)JINKO SOLAR JKM430N-54HL4-B MODULES MATTITUCK, NY 11952, (22) ENPHASE IQ8MC-72-M-US (240V) MICROINVERTERS �„_ atgeachRd :— " sue, USA, (01) ENPHASE IQ COMBINER 515C PANEL `i f` +1 631 760 7262 CODES AND STANDARDS WITH AMENDMENTS LIC TYPE: HOME 2020 BCNYS 2020 FCNYS EXISTING PV SYSTEM i IMPROVEMENT, MASTER - . - - " ' 2020 RCNYS (23) LG3 15NIC-G4 PV MODULES ELECTRICIAN (01) SOLAREDGE SE760OH-US (240V) INVERTER , ," Q LIC NO.: 67461-1-1I, 2017 NEC ;Pp 'Ra Southold,NY 52689-ME Ui 11571,United States PROJECT INFO&ADDRESS ENVIRONMENTAL , DEBRA CORITSIDIS WIND SPEED: 134 MPH ayv+ewrtd SNOW LOAD: 25 PSF 1800 CEDAR BEACH RD, -- -- k EXPOSURE CATEGORY: C SOUTHOLD, NY 11971, USA SYSTEM SIZE GENERAL NOTES SHEET INDEX DC SIZE: 9.460 KW DC-(STC) PROJECT NOTES: -THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH PV-1 COVER SHEET AC SIZE: 7.040 KW AC THE NATIONAL ELECTRIC CODE (NEC)ARTICLE 690,ALL PV-2 SITE PLAN - 1 METER NO: 80421327 PV-2.1 SITE PLAN -2 MANUFACTURER'S LISTING AND INSTALLATION INSTRUCTIONS,AND THE RELEVANT CODES AS SPECIFIED ACCT NO: 9768162704 PV-3 ATTACHMENT PLAN BY THE AUTHORITY HAVING JURISDICTION'S (AHJ) PV-3.1 STRUCTURAL PLAN �,� PV-4 ELECTRICAL ' 1. `a + APPLICABLE CODES. -THE UTILITY INTERCONNECTION APPLICATION MUST BE PV-4.1 ELECTRICAL CALCULATIONS - } APPROVED AND PV SYSTEM INSPECTED PRIOR TO PV-5 LABELS RESOURCE DOCUMENT PV-6 PARALLEL OPERATION -GROUND FAULT DETECTION AND INTERRUPTION (GFDI) PV-6.1 RESOURCE DOCUMENT DEVICE IS INTEGRATED WITH THE MICRO INVERTERS IN PV-6.2 RESOURCE DOCUMENT ACCORDANCE WITH NEC 690.41(B) PV-6.3 RESOURCE DOCUMENT -ALL PV SYSTEM COMPONENTS; MODULES, UTILITY- PV-6.4 RESOURCE DOCUMENT 'VA r92;g{ INTERACTIVE INVERTERS,AND SOURCE CIRCUIT COMBINER PV-6.5 RESOURCE DOCUMENT Q`,, or r r�`s BOXES ARE IDENTIFIED AND LISTED FOR USE IN PV-6.6 RESOURCE DOCUMENT -.. `'`'-! �� PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4: PV PV-6.7 RESOURCE DOCUMENT W ssil,ng Cansu l ing,PLLC MODULES: UL1703, IEC61730,AND IEC61215,AND NFPA 70 PV-6.8 RESOURCE DOCUMENT 781 -"1 eadowbraok Drove,Alpine UT CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, PV-6.9 RESOURCE DOCUMENT ew York.OOA#0022571 929, 519 COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY Signed 10/27/2025 -MAX DC VOLTAGE CALCULATED USING MANUFACTURER Expires 7/31/2027 PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7. -ALL INVERTERS, PHOTOVOLTAIC MODULES,PHOTOVOLTAIC 11 isaviolationof.ihelawforany'person;unless PANELS,AND SOURCE CIRCUIT COMBINERS INTENDED FOR a"ctirig:uniterthe directior:4f;a licensed DRAWN BY RG USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE professionat,toalteran item in anyway.ffan DATE 10/24/2025 IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4. itembQaring'the seatnf a:licensedprofessidna,l SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS 'is altered,the-akeringlicensed professional shalt REVISION FROM LISTING OR LABELING [NEC 110.3]. affix tobrieir Rem theiiaeal and the natation SIGNATURE -ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL "Olteredby"fb0gwedtty7their signature and the- BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV date+oifsuch:alteration,and a;specific PV-1 RESISTANT.ALL PLAQUES AND SIGNAGE WILL BE INSTALLED description of'the•alteration. AS REQUIRED BY THE NEC AND AHJ. COVER SHEET SCOPE OF WORK CONTRACTOR (N) 9.460KW DC/7.040KW AC ROOF MOUNTED PV SYSTEM TOTAL ROOF SQUARE FOOTAGE IS: 2229.19 FT � ® ELEMENT NEW ARRAY SQUARE FOOTAGE IS: 462.42 FTz ENERGY (22)JINKO SOLAR JKM430N-54HL4-B MODULES (22) ENPHASE IQ8MC-72-M-US (240V) MICROINVERTERS COVERED BY SOLAR IS: 20.74% SOLARI BATTERY BACKUP 1631.779.79931 E2sYs.rom (01) ENPHASE IQ COMBINER 5/5C PANEL ELEMENT ENERGY LLC EXISTING PV SYSTEM 7470 SOUND AVE, (23) LG3 15NIC-G4 PV MODULES MATTITUCK, NY 11952, (01) SOLAREDGE SE760OH-US (240V)INVERTER USA, +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN LIC NO.: 67461-HI, 62689-ME PROJECT INFO&ADDRESS 202,_911 DEBRA CORITSIDIS 1800 CEDAR BEACH RD, Q ' NY 119711, USA SYSTEM SIZE O 70"611 DC SIZE: 9.460 KW AC SIZE: 7.040 KW ACUj (STC) m � ' It is a v9olation.6f.the lava forany person,u n[ess actingunder.the direction of.a licensed QQ c / professional,tv alter.an item in any Way.lFan n ag item bearingthe seslof aticensed professional ' �C _ f U C:� 'is altered,,thealteringlicensed profession tit shall t:) kv affixtotheiritemtheir.sealandihenotation 1 '� "altered;by"-followed bytheir-signature and the q — — � date of such alteration,and a specific _ description of the alteration_ 33 04,-811 :ry �aT II iJ 11T (E)MAIN HOUSE 7�Yylssling Consulting, PLLC 76 N.P leado'w brook D ve,.APine UT New York 1COA#0022571 LEGEND Signed 10/27/2025 I Expires 7/31/2027 ®FIRE PATHWAYS N PROPERTY LINE 0 FENCE DRAWN BY RG ® SKYLIGHT/CHIMNEY O ❑ VENT/OBSTRUCTION DATE 10/24/2025 REVISION SIGNATURE SITE PLAN - 1 PV-2 SCALE: 1/32" = V-0" SITE PLAN - 1 SCOPE OF WORK CONTRACTOR (N) 9.460KW DC/7.040KW AC ROOF MOUNTED PV SYSTEM TOTAL ROOF SQUARE FOOTAGE IS: 2229.19 FT2 ELEMENT (22)JINKO SOLAR JKM430N-54HL4-B MODULES NEW ARRAY SQUARE FOOTAGE IS: 462.42 FT d Ej ® ENERGY (22) ENPHASE IQ8MC-72-M-US (240V) MICROINVERTERS COVERED BY SOLAR IS:20.74% SOLAR I BATTERY BACKUP163t.779.79931 E2SYS.COM (01) ENPHASE IQ COMBINER 5/5C PANEL �Q ELEMENT ENERGY LLC EXISTING PV SYSTEM 7470 SOUND AVE, (23) LG3 15NIC-G4 PV MODULES !,P MATTITUCK, NY 11952, (01) SOLAREDGE SE760OH-US (240V) INVERTER USA, (E)(01)SOLAREDGE SE760OH-US a +1 631 760 7262 (240V)INVERTER �O� .• LIC TYPE: HOME (INSIDE BASEMENT) r• IMPROVEMENT, MASTER (N)ENPHASE IQ COMBINER 5/5C V 3 LADDER ACCESS-2 ELECTRICIAN WITH ENPHASE IQ GATEWAY (OUTSIDE HOUSE)- LIC NO.: 67461-HI, (N)VISIBLE LOCKABLE LABELED l 62689-ME AND FUSED AC DISCONNECT L �� (UTILITY DISCONNECT) (OUTSIDE HOUSE) PROJECT INFO&ADDRESS (E)VISIBLE LOCKABLE LABELED POD Gp S AND FUSED AC DISCONNECT] � DEBRA CORITSIDIS (UTILITY DISCONNECT) J� ��� O 1800 CEDAR BEACH RD, (OUTSIDE HOUSE) 'Q�, nj� SOUTHOLD, 5Q (E)UTILITY METER 0) NY 11971, USA (OVERHEAD SERVICE) Q� L (OUTSIDE HOUSE) O SYSTEM SIZE (E)MAIN SERVICE PANEL (INSIDE BASEMENT) � � DC SIZE: 9.460 KW DC-(STC) AC SIZE: 7.040 KW AC (E)ATS PANEL O ItJs a violationdf#helawforany"person,unless (INSIDE BASEMENT) actingunder.the direction af.a•licensed professional,to alteran item in any way ifanIN itembearing the sealofa:ticensedprofessional �� of I_ rl. 0 �O is altered,the altering.licensed professional shaft c� �., 1.1v ^ �� affix to their iterntheir.seaL4hd-heiiotation L , t - ''altered by"-foyowed by their signature and the j`t date of such.alteration,and,a specific � description ofthe alteration. (N)(22)JINKO SOLAR JKM430N-54HL4-B MODULES WITH � . ENPHASE IQ8MC-72-M-US(240V)MICROINVERTERS - 0 UNDER EACH MODULE(240V) I slding Consulting, PLLC 76 N.Meadowbrook-Drive,.AlRine U New York CGrA#0022571 Signed 10/27/2025 Expires 7/31/2027 LEGEND ®FIRE PATHWAYS O i PROPERTY LINE M 0 FENCE 3'-O" DRAWN BY RG ® SKYLIGHT/CHIMNEY ACCESS ROOF DATE 10/24/2025 O ❑ VENT/OBSTRUCTION REVISION (E)(23) LG3 15NIC-G4 PV MODULES SIGNATURE SITE PLAN - 2 LADDER ACCESS-1 PV-2.1 SCALE: 1/8"=1'-O" SITE PLAN - 2 CONTRACTOR ROOF SECTION(S) S-8" ELEMENT ROOF MATERIAL- ENERGY COMPOSITE SHINGLE 15'-011 13'-5" 181-911 7 1011 BCLAR I BATTERY BACKUP 1631.779.79931 E2SYS.C13M ROOF 1 RAFTER SIZE-2"X6" O.C. SPACING- 16" JI I I I I I I I I I I I I I I I I I I I I I I ELEMENT ENERGY LLC MODULES- 14 I i i i i 1 I I I i i i 1 i i i I I I 1 7470 SOUND AVE, I I i ROOF MATERIAL- I I i I C- ? MATTITUCK, NY 11952,COMPOSITE SHINGLE 1 I I I I I I I I I I 1 t 1 1 I 1 I USA,ROOF 2 RAFTER SIZE-2"X6" 1 i i i i i i i I I I I I 1 I I 1 1 +1 631 760 7262 O.C. SPACING- 16" MODULES- 3 1 1 1 1 1 1 1 1 1 1 1 LIC TYPE: HOME I I I I I I I I I I I I I 1 1 1 1 1 1 1 I I I I I I I I I I I I 1 I I I I I IMPROVEMENT, MASTER ROOF MATERIAL- 1 1 1 1 ARRAY ELECTRICIAN COMPOSITE SHINGLE I I I I I I I I I ROOF 3 RAFTER SIZE-2"X6" 1 1 1 1 1 1 1 1 1 1 TILT- 18 DEG I 1 I LIC NO.: 67461-HI, O.C. SPACING- 16" i i 1 I I 1 I I i I 52689-ME AZIMUTH - 43 DEG I MODULES- 5 I I I I I I I 4'-0" I PROJECT INFO&ADDRESS DEBRA CORITSIDIS 1800 CEDAR BEACH RD, SOUTHOLD, 8'-4" 7'-6" 2" 9'-4" 11'-3" 41' NY 11971, USA SYSTEM SIZE I I I I I I I I I I I I I I I I I I I I 1 1 DC SIZE: 9.460 KW DC-(STC) I I I I 1 - 1 1 1 1 1 AC SIZE: 7.040 KW AC I I I I I I ti - I I I I I I I IT 1 I 1 ARRAY 3 Itis a violation of the law for any person,unless ARRAY 2 TILT- 17 DEG ctingunderthedir®ctionof.alicensed TILT- 18 DEG I I I I 1 1 I AZIMUTH - 313 D fo essional to.alter an item in any way.if an AZIMUTH - 133 DEG I I I I I I I I I item bearingthe seaL.of a€icensed professional - `!� � I I I 1 1 1 i I i I i I I I I I 'is altered,,the altering licensed professional sha L LO by 1 11 I I I I I I I I affix totheir item their-seaLandthe-notation �'� 4 _ I I IT I T1I I71 "alteredby-fo(lowed'bytheir signature and the fir t J 1 I I I 1 date of such alteration,and a specific I I I I 1 I I I I I I description of the alteration. :rya a DEAD LOAD CALCULATION v -- BOM QUANTITY LBS/UNIT TOTAL Wys- sling Consulfing, PLfLC WEIGHT(LBS) 6.N_.Meadaxwbriaolk®Hive,Alpine JINKO SOLAR 22 48.50 1067.00 New York COA#0022571 0 - CLAMP JKM430N-54HL4-B MODULES Signed 10/27/2025 MID-CLAMP 26 0.15 3.90 Expires 7/31/2027 • - IRONRIDGE HALO ULTRA GRIP END-CLAMP 36 0.15 5.40 RAIL LENGTH 20 6.36 127.20 - IRONRIDGE AIRE RAIL Al SPLICE BAR 02 0.525 97.00 -------- - RAFTER IRONRIDGE HALO ULTRA 62 0.57 35.34 DRAWN BY RG GRIP 62 -TOTAL MOUNT ENPHASE IQ8MC-72-M-US 22 2.43 53.46 DATE 10/24/2025 (240V) MICROINVERTER I I REVISION TOTAL WEIGHT OF THE SYSTEM (LBS) 1389.30 TOTAL ARRAY AREA ON THE ROOF (SQ.FT) 462.42 SIGNATURE 1 ATTACHMENT PLAN WEIGHT PER SQ.FT. (LBS) 2.31 PV-3 WEIGHT PER PENETRATION (LBS) 22.41 SCALE:1/8"=1'-0" ATTACHMENT PLAN CONTRACTOR L M ELEMENT ENERGY SOLARI BATTERY BACKup 1631.779.79931 E2SYS.C13M ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11952, USA, +1 631 760 7262 LIC TYPE: HOME MODULE BOTTOM MOUNTING CLIP IMPROVEMENT, MASTER ELECTRICIAN CLAMP w 4" BOLT LIC NO.: 67461-HI, AND LOCK WASHER 52689-ME PROJECT INFO&ADDRESS JINKO SOLAR JKM430N-54HL4-B MODULE DEBRACORITSIDIS 1800 CEDAR BEACH RD, SOUTHOLD, IRONRIDGE AIRE RAIL Al NY 11971, USA 3. BOLT SYSTEM SIZE 8 j DC SIZE: 9.460 KW DC-(STC) i i AC SIZE: 7.040 KW AC COMPOSIT !sa�,�a.IoN%Ewf oranyperson,unless $cfing underthe d[rection ofta licensed RO N R I DG E HALO ULTRA GRIP / _professional,to attar an item in anyway,tf an :jtem:bearingthesealofa€icensedprofeWonal 'is altered,the altering licensed professional•sha i affixtotheiritemtheir.sed ndthe'notation atferedby"fottowed-by their signature.and the date of such alteratFon,and a specific n k f -� y >, description ofthe•atteration. 4; r.. + (2) #14 X 3" STAINLESS STEEL SCREWS, SELF DRILLING _ SCREW, WITH MINIMUM 2" %sslaj�`C g ConsvOlbir+g;Pi_ILC 2 EMBEDMENT - 6 N-Meae owbroo.k©nive,Alpine UT NOW York COA#0022571 Signed 10/27/2025 Expires 7/31/2027 (E) RAFTER 211X611 @ 1611 O.C. DRAWN BY RG DATE 10/24/2025 REVISION SIGNATURE 1 STRUCTURAL PLAN PV-3.1 SCALE:NTS STRUCTURAL PLAN CONTRACTOR NOTE: METER NO: 80421327 ALL CONDUCTORS ARE COPPER UNLESS OTHERWISE NOTED. Id M ELEMENT ACCT NO: 9768162704 L- ENERGY SOLAR BATTERY BACKUP 1631.779.79931 EZSYS.COM TO UTILITY GRID (N)(22)JINKO SOLAR JKM430N-54HL4-B (N)(1)ENPHASE IQ COMBINER 5/5C L7 L2 N MODULES WITH ENPHASE IQ GATEWAY, (E)BI-DIRECTIONAL UTILITY ELEMENT ENERGY LLC _ (2)20A/240VAC CIRCUIT LINE METER 1-PHASE,3-W, N 11 MICROINVERTERS IN BRANCH CIRCUIT 1 BREAKER 125A RATED (N)(1)AC DISCONNECT: 120V/24OV,200A RATED 7470 SOUND AVE, (2)#12 Q-CABLES (OUTSIDE HOUSE) VISIBLE,LOCKABLE,LABELED M (OVERHEAD SERVICE) MATTITUCK, NY 11952, ... 100A FUSED,(2)40A FUSES, (OUTSIDE HOUSE) ETE�g� IO GATEWAY NEMA 3R,UL LISTED LOAD USA, PER MANUFACTURER UTILITY DISCONNECT +1 631 760 7262 SPECIFICATIONS,EITHER VVIR ESs E MAIN SERVICE PANEL, I = I I 10A OR 15A OR 20A (OUTSIDE HOUSE) ( ) COMMS LIC TYPE: HOME ti BREAKER IS L7 L7 SUPPLY SIDE TAP 200A RATED,240V —— ——— SUITABLE FOR USE L2 L2 (INSIDE BASEMENT) IMPROVEMENT, MASTER 15AI2P " ELECTRICIAN 11 MICROINVERTERS IN BRANCH CIRCUIT 2 I G LINE c — 2i,A LIC NO.: 67461-HI, I' I (E)ATS BREAKER I 20w2P I z I I 2 I 240 v,200A/2P 52689-ME ED I r I E I PROJECT INFO&ADDRESS ti l ti I ti I I 20Al2P I I I J—— ——— I r———— — — , (E)MAIN BREAKER DEBRA CORITSIDIS LOAD I (E)ATS PANEL,200A I o TO HOUSE 240 V, RATED,240V 20OAl2P 1800 CEDAR BEACH RD, (N)(22)ENPHASE IQ8MC-72-M-US I I I r—L— G (INSIDE BASEMENT) I (BOTTOM FED) SOUTHOLD (240V)MICROINVERTERS ONE UNDER EACH MODULE(240V) I I L— ——— J I t GEC I LINE SIDE I NY 11971, USA N INTERCONNECTION I — G L--- ---� L I � AT ATS PANEL G I - I PER ART.705.12(A) SYSTEM SIZE 1 EXISTING GROUNDING DC SIZE: 9.460 KW DC-(STC) (E)(23)LG3 15NIC-G4 PV MODULES I ELECTRODE SYSTEM I AC SIZE: 7.040 KW AC TO EARTH E REF.NEC 250.52, IL IS 8 Y16lBtion of.the Iaw fOr Bny Person,unim = I 250.53(A) satin •undertiie-dfredtion-of:aiidensed I ti SOLAR MO U`LE SPECIFjjCATIpNS, z s o 0 o ,z 13 I ti; lnaeaai�n anv_.@y 'n I ,°& AO I (E) GENERATOR MANUFACTURER/M06Yirin#ie € r; f s �� �'11 " - — + + I (E)(1)AC DISCONNECT: ur190E�' Lgf,1,,igqTqq-se�[p —33 nal VISIBLE,LOCKABLE,LABELED 100A FUSED,(2)40A FUSES,240V I VMP is a tere tering loense Pro es$lon she'l �J NEMA 3R,UL LISTED fi ISO, elf lt-fl�tf'lel r.SE—�8� le—n-Ot�IO� 0 0 0 = = I I I (UTILITY DISCONNECT) I IMP + - (OUTSIDE HOUSE) itere {DWEt]"by'Lh21Y-siEmaturq n the. Y ------- I I I VOC �s,,.16 � � tf —— ——— detet�f--sheft elteratfari at�d�speoifi ISC 113.65 Ik z a o 0 0 09 10 —r(E) ———— ——J L—_ LINE —J TEMP.COEFF.VOC 0.25%/°C J3, )SOLAREDGE SE7600H-US(240V) E DULE DIMENSION 69.36"L x 44.65"Wx 1.38"D(In Inch)+ + + 600W OUTPUT:240 VAC,32A————— MO %CEC WEIGHTED EFFICIENCY I �`�•� V �J 0 0 0 NEMA 4X,UL LISTED,INTERNAL GFDI I I INVERTER SPECIFICATIONS + ------- + + WITH INTEGRATED DC DISCONNECT I ENPHASE IQ8MC-72-M-US (240V) (INSIDE BASEMENT) I MANUFACTURER/MODEL# Wyssling Cansufbing, PL.0 LOAD MICROINVERTER . 6 N.Meadowbfoo,k Drive,Alpine UT MIN/MAX DC VOLT RATING 22V MIN/58V MAX New You t COA#0022571 MAX INPUT POWER 460W Signed 10/27/2025 L—— —— J NOMINAL AC VOLTAGE RATING 240V/211 V-264V Expires 7/31/2027 MAX AC CURRENT 1.33A MAX MODULES PER STRING 12 (SINGLE PHASE) MAX OUTPUT POWER 320 VA DRAWN BY RIG PHASE CONDUCTOR QTY, SIZE AND TYPE GROUND CONDUCTOR QTY, SIZE CONDUIT CONDUIT DATE 10/24/2025 ID PER CONDUIT NEUTRAL QTY, SIZE AND TYPE PER CONDUIT AND TYPE PER CONDUIT SIZE TYPE REVISION SIGNATURE 1 2 AWG#12 SKU NA NA NA 1 AWG#8 BARE,COPPER EGC 3/41' PVC PV-4 2 AWG#6 THWN-2,COPPER 1 AWG#6 THWN-2,COPPER 1 AWG#6 THWN-2,COPPER EGC 3/4" PVC 2 EE EXISTING CONDUITS AND WIRES ELECTRICAL CONTRACTOR N ELEMENT AMBIENT TEMPERATURE SPECS INEJENERGY SOLAR I BATTERY BACKUP I r.31.779.7993 J USYS.COM RECORD LOW TEMP -140C PERCENT OF NUMBER OF CURRENT ELEMENT ENERGY LLC AMBIENT TEMP (HIGH TEMP 2%) 270C VALUES CARRYING CONDUCTORS IN CONDUIT 7470 SOUND AVE, CONDUIT HEIGHT 7/8" MATTITUCK, NY 11952, .80 4-6 USA, ROOF TOP TEMP 490C +1 631 760 7262 CONDUCTOR TEMPERATURE RATE 75°C .70 7-9 LIC TYPE: HOMEIMPROVEMENT, MASTER MODULE TEMPERATURE COEFFICIENT OF Voc -0.25%/°C 50 10-20 ELECTRICIAN LIC NO.: 67461-1-1I, 52689-ME PROJECT INFO&ADDRESS CALCULATIONS: DEBRA CORITSIDIS 1800 CEDAR BEACH RD, 1. CURRENT CARRYING CONDUCTOR 2. PV OVER CURRENT PROTECTION ...NEC 690.9(B) SOUTHOLD, = TOTAL INVERTER O/P CURRENT x 1.25 NY 11971, USA (A) BEFORE IQ COMBINER PANEL = (22 x 1.33) x 1.25 = 36.58 A SYSTEM SIZEDC SIZE: 9.460 KW DC-(STC) AMBIENT TEMPERATURE - (27)OC ...NEC 310.15(B)(2)(a) AC SIZE: 7.040 KW AC TEMPERATURE DERATE FACTOR - 1 ...NEC 310.15(B)(2)(a) GROUPING FACTOR - 0.8...NEC 310.15(B)(3)(a) 1iIsa'Vriolation cif-the lawforanyperson.unless: :acdngunder the dl-rection of.a licensed CONDUCTOR AMPACITY Professior,aL,to alter an iterrD in anyway:If an atem.bearing the sealofafieensedProfessional 'is.altered,the:alterin licensed rofessional sha!i ca I (INV O/P CURRENT ) x 1.25 / A.T.F / G.F ...NEC 690.8(B) affixto Their item thegseaLand;thenotation ,-T [(11 x 1.33) x 1.251 / [1 x 0.81 "altered by'fb.bwedbytheirsignatureandthe = 22 86A date of such alteration �,and a specific f3 descriptionoftheatteration. SELECTED CONDUCTOR — #12 THHN ...NEC 310.15(B)(16) 4fL, Lr Wyssieng Consulting,:PLLIC (B) AFTER IQ COMBINER PANEL 16 N.Meadowbrook D awe,.Alpine UT TEMPERATURE DERATE FACTOR — 1 NP-w York COA46022571 GROUPING FACTOR — 1 Signed 10/ 1/2025 Expires 7/3 /2027 CONDUCTOR AMPACITY DRAWN BY RG _ (TOTAL INV O/P CURRENT) x 1.25 / 1/ 1 ...NEC 690.8(B) DATE 10/24/2025 = [(22 x 1.33) x 1.251 / [I x 11 = 36.58 A REVISION SELECTED CONDUCTOR — #8 THWN-2 ...NEC 310.15(B)(16) SIGNATURE PV-4.1 ELECTRICAL CALCULATIONS CONTRACTOR P ' CAUTION:SOLAR ELECTRIC ELEMENT R � ® ENERGY ELECTRIC ® v BATTERY BACKUP1631.779.79931 E25YS.COM C SYSTEM CONNECTED I SHOCK HAZARD CAUTION 50LARl B IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE ELEMENT ENERGY LLC MAY BE UNGROUNDED AND ENERGIZED SOLAR PV SYSTEM EQUIPPED FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: 7470 SOUND AVE, WITH RAPID SHUTDOWN MATTITUCK, NY 11952, TURN RAPID SHUTDOWN USA, 2 P i SWITCH TO THE 2O N +1 631 760 7262 "OFF"POSITION TO sawxe�crnic `CC SHUTDOWN PV SYSTEM wvnne�s �.� LIC TYPE: HOME F-] F91 ELECTRIC SHOCK HAZARD AND REDUCE V SHOCK HAZARD P IMPROVEMENT, MASTER THE DC CONDUCTORS OF THIS IN THE ARRAY ELECTRICIAN PHOTOVOLTAIC SYSTEM ARE UNGROUNDED .01 AND MAY BE ENERGIZED P LIC NO.: 67461-1-1I, COMBINER PANEL ��/ 52689-ME (OUTSIDE HOUSE) PV D ® 1 CA I© • SOLi4R CIRCUIT UTSDEO NNECT (O HOUSE) y ara PV DISCONNECT PROJECT INFO&ADDRESS (OUTSIDE HOUSE) ELECTRIC SHOCK HAZARD UTILITY METER P5 DEBRA CORITSIDIS DO NOT TOUCH TERMINALS (OVERHEAD SERVICE) TERMINALS ON BOTH LINE AND MAIN(OUTSIDE SERVICE PANEL 1800 CEDAR BEACH RD, LOAD SIDES MAY BE ENERGIZED (INSIDE BASEMENT) SOUTHOLD, IN THE OPEN POSITION A A OUTPUTRATED AC CURRENT ATS PANEL NY 11971 USA 1 1NOMINAL OPERATING AC V• I VOLTSt (INSIDE BASEMENT) INVERTER (INSIDE BASEMENT) SYSTEM SIZE WARNING DC SIZE: 9.460 KW DC-(STC) V No user serviceable parts inside All SIZE: 7.040 KW AC PV ARRAY It f a biolation of the law forleny Rerso .unless C'rig underthedirection of;a license F5-1P AR G' I7UA O RSOURCE �. professional,to,alter an itern in any w :tf an SECQ D SOURCES HOTOVO !AIC S STEM, i item.bearing the seal of a licensed pro essional • • • s 'is altered,the altering licensed professional she CD 6] WARNING: affix-to theiritemtheir.sealandthano tion to • • • "altered by"followed bytheirsi_gii I and the 4 ? a date i such.alteratfon,and a specific J L Ill WARNING description of the alteration. �(s ¢� 6-7] j 4 INVERTER OUTPUT CONNECTION DO NOT RELOCATE OVERCURRENT DEVICE Solar Module Solar Module Micro Inverters `` ';.�r�' COMBINER PANEL AC DISCONNECT ATS Panel Main Service Panel �, 12LL L Outside Door Outside Door WySSItf1tg" Consult inn,'PLLLC Outside Door 3,9,10 3,9,10 6 N.Meadowbil o4.k Dfgve,AlpineT 3,4,11,12 3,6,8,9,11 Inside Door Inside Door New York COA#0022571 Inside Door 5,16 7 5,6,7 OEM Cables should be marked by the manufacturer 5,6,7 *Custom Signed 10/27/2025 NEC 690.13(B) Directory Expires 7/31/2027 NEC 690.54 Placard NEC 690.51 NEC 690.13(B)NEC 705.12(A) NEC 705.12(B)(3) NEC 690.13(B) NEC 690.13(B) NEC 690.56(B) NEC 690.56(B) NEC 69D705.56(B)NEC 705.12(B)(3) NEC 705.10 NEC 705.10 Solar Module Solar Module NEC 705.10 NEC 705.12(A) NEC 705.12(A) Optimizers NEC 705.12(B)(3) NEC 705.12(B)(3) DRAWN BY RG Solar-Edge Inverter AC DISCONNECT DATE 10/24/2025 Outside Door REVISION Inside Door OEM Cables should be marked by the manufacturer SIGNATURE NEC 691 NEC 690.54 PV-5 NEC 690.56(C) NEC 705.12(8)(3) NEC 690.13(B)NEC 705.12(A) NEC 690.56(B)NEC 705.12(B)(3) LABELS NEC 705.10 CONTRACTOR ELEMENT �,. in ENERGY SOLARI BATTERY BACKOP1631.779.79931 E2SY5.COM ENGINEERING DRAWINGS MECHANICAL CHARACTERISTICS ELEMENT ENERGY LLC Front Side Back No.of Half Cells 108(2x 541 7470 SOUND AVE, 11aLmmltL.iS'I 1°96m.-n(1- ' r ~ _ _ ._1. Dimensions 1722 x 1,34 x 35mm(67.79 x 44.65 x 1.38 inehl MATT ITUCK, NY 11952, Weight 22.Okg 148.S1bs11 USA, I Front Glass 3.2mm,Anti-Reflection Coating +1 6 1 760 7262 THE - __ - _ •' i High Transmission,Law Iron,Tempered Glass ,\. J ._ J .-\. _i. j _ .L F Frame Anodized Aluminum Alloy LIC TYPE: HOME I , ' , BLE - ! ' e 3 Junction Box IP68 Rated IMPROVEMENT, MASTER E _�� i. i `" Output Cables 12 AV7G,1400 (55.12in1 Customized Length i mm or ELECTRICIAN SOLAR PRODUCT Connector staubliMC4 LIC NO.: 67461-HI :. .. Fire Type e Type e 1 t - Pressure Rating 5400PaISnowl&2400Pa(Wind) 52689-ME EAGLE8 54 G6R �_ �r PROJECT INFO&ADDRESS TEMPERATURE CHARACTERISTICS DEBRACORITSIDIS 420-440 WATT• N-TYPE TOPCON Length ±2mm Temperature Coefficients ofPmax -0.29%/°C i - ::�I��. . Positive power tolerance of 0-+3/0 o Width;+2mm Temperature Coefficients ofVoc -0.25°e!°C 1800 CEDAR BEACH RD, . I- _ Temperature Coefficients of isc O.045I/1C SOUTHOLD, Row Pitch:t 2mm - ° en Nominal Operating Cell Temperature(NOCTI 45±2°C NY 11971, USA • NYSE-listed since 2010,Bloomberg Tier 1 manufacturer SYSTEM SIZE • Top performance in the strictest 3rd party labs ELECTRICAL PERFORMANCE&TEMPERATURE DEPENDENCE MAXIMUM RATINGS DC SIZE: 9.460 KW DC-(STC) • Automated manufacturing utilizing artificial intelligence current-Volta e&Power-Volta e Temperature Dependence AC SIZE: 7.040 KW AC 9 9 P p Operating Temperature(°CI -40'C-+85°C • Vertically integrated,tight controls on quality Curves(440W1 o11sc,Voc,Pmx Maximum System Voltage 100aVDC • Premium solar factories in USA,Vietnam,and Malaysia Maximum series Fuse Rating 25.4 3S^. KEY FEATURES PACKAGING CONFIGURATION Superior Aesthetics - - c ° lTwo pallets=One stack] S Black backsheet and b-ack frame create:deal look for 'c z m ro as ss ee 31pcs/pallets,62pcs/stack,806pcs/40 HO Container es dewial applications. Voltage IV] N-Type Technology p N-typece.1s with Jintc's in-house TOPContecnnology • u a: ° n se s +:e WARRANTY Cell Tem erature Pr)offers better performance and improved reliability. P • 25-year product and 30-year linear power warranty 00Thick and Tough i°t year degradation not to exceed 1%,each subsequent year not to Fire Type l rated module engineered w1th a thick frame, exceed 0.4%,minimum power at year 30 is 87.4%or greater. 3.2mm from side otass,and:hick backsheet for added durability. Shade Tolerant ELECTRICAL CHARACTERISTICS Train array desicn allows continued pe-formance Module Type JKM420N-54HL4-B JKM425N-54HL4-B JKM430N-54HL4-B JKM435N-54HL4-B 1KM440N-54HL4-B even Vvith shading.by trees or debris STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT 0 Protected Against All Environments Maximum Power(Pmaxl 420Wp 314Wp 425Wp 320Wp 43OWp 323Wp 435Wp 327Wp 440Wp 331Wp Certified to viths!arid numld:ty,heat•rain,marine environments, Maximum Power Voltage(Vmpl 3216V 29.95V 32.37V 30.19V 32.56V 30.30V 32.78V 30.50V 32.99V 30.73V vend,hailstorms,and packed snow. IAaxirnum Power Current limp) 13.06A 10.55A 13.13A 10.60A 13.20A 10.66A 13.27A 10.72A 13.34A 10.77A Warranty Open-circuit Voltage lVocl 38.74V 36.80V 3895V 37.00V 39.16V 37.20V 39.36V 37.39V 39.57V 37.59V 25-year product and 30-year linear pnwer warranty. short-circuit current Rscl 13.51A 10.91A 13.58A 10.96A 13.65A 11.02A 13.72A 11.O8A 13.80A 11.14A Module Efficiency STC(%I 21.51% 21.76% 2102% 22.28% 22,53% 'STC: c:Irradiance 1000W/ml Cell Temperature 25°C (�f) AM=1.5 DRAWN BY RG • 1SO9001:2015 Quality Star.dares 1SO45001:20180ccupationa! -- \ ', NOCT:,�.Irradiance 800W/m'- z, Ambient Temperature 20'C � AM=1.5 Wind Speed lm/s • ISnl40Ci:2015Environment.[Standards Health&Safety Standards � VL us DATE 10/24/2025 'Power measurement tolerance;±3% • IEC61215,IEC61730 certiriee prucuas UL61730 cer;llied p\oducts CE- LISTED . �•af.G7 The company reserves the first 6ghifor explanation on anyol the inlurmatim presented hereby.JKM4J0-.23h'-54HL4-n-Fi-US REVISION BUILDING YOUR TRUST IN SOLAR.WWW.JINKOSOLAR.US •fink® BUILDING YOUR TRUST IN SOLAR.WWW.JINKOSOLAR.US Jinl<® SIGNATURE PV-6 RESOURCE DOCUMENT CONTRACTOR ELEMENT -N M ENERGY BOLARI BATTERY 13ACKUP1631.779.79931 E2BYS.1313M ENPHASE. �01 IQ8MC Microinverter ELEMENT ENERGY LLC INPUT DATA CDC) UNITS 7470 SOUND AVE, Commonly used module pairings tv 260-460 MATTITUCK, NY 11962, USA, wModule compatibility To meet Module compatibility PV modules checked be within the following max.input / voltage and max.module IK 1 631 760 7262 Module compatibility can be checked at http_//onnfiasmcom/installore/microinverters/calculator. + MPPT voltage range v 25-45 LIC TYPE: HOME Operating range v - 16-58 IMPROVEMENT, MASTER MinJMax.start voltage v '22/58 ELECTRICIAN Max-input DC voltage v 60 LIC NO.: 67461-HI, Max.continuous operating DC current A 14 62689-M E Max.input DC short-circuit current A 25 Max.module lF A _ 2.0 PROJECT INFO&ADDRESS Overvoltage class DC port 11 DC port backfeed current mA 0 DEBRA CORITSIDIS PV array configuration Ungrounded array;no additional DC side protection required;AC side protection requires max 20 A per branch circuit 1800 CEDAR BEACH RD, OUTPUT DATA(AC) UNITS I IQSMC-72-M-US @208 VAC SOUTHOLD, Peak output power VA 315 NY 11971, USA Max.continuous output power VA 320 310 Nominal grid voltage(L-L) v 240,split-phase(L-L),180' 208,single-phase(L-L),120• SYSTEM SIZE IQ8MCMicroinverter Easy to install Min./Max.grid voltages v 211-264 183-229 DC SIZE: 9.460 KW DC-(STC) Our newest IQ8 Series Microinverters are the industry's first micro Lightweight and compact with plug- Max.continuous output current A 1.33 1.49 AC SIZE: 7.040 KW AC g rid-formin g',software t nn l nd-pay connectors defined microinverters with split-phase power conversion capability to convert DC power to a Nominal frequency Hx 60 AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary Power line communication(PLC) Extended frequency range Hz 47-68 application-specific integrated circuit(ASIC),which enables the microinverter to operate in between components grid-tied or off-grid modes.This chip is built in advanced 55-nm technology with high-speed AC short circuit fault current over three digital logic and has superfast response times to changing loads and rid events,alleviating Faster installation with simple two-wire cycles A— constraints 9 9 P P 9 9 9 9 cabling y constraints on battery sizing for home energy systems. Max.units per 20 A(L-L)branch circuit' 12 10 High productivity and reliability Total harmonic distortion % c5 ^i Produces power even when the grid is ➢M down' Ovewoltage class AC port III More than one million cumulative hours AC portbackfeed current mn 18 of testing Power factor setting LO Part of the Enphase Energy System, IQ8 Series Microinverters redefine Class II double-insulated enclosure Grid-tied power factor(adjustable) 0.85leading...0.85 lagging I018 Series Microinverters integrate with reliability standards with more than one Optimized for the latest high-powered the IQ Battery,IQ Gateway,and the million cumulative hours of power-on PV modules Peak efficiency q 97.4 972 Enphase App monitoring and analysis testing,enabling an industry-leading CEC weighted efficiency yc 97.0 96.5 software. limited warranty of up to 25 years. Micragrid-forming Nighttime power consumption mw 33 -25 Complies with the latest advanced grid MECHANICAL DATA UNITS Ca � support Ambient temperature range -40"C to 651C(-401F to 149'F) • Remote automatic updates for the CERTIFIED latest grid requirements Relative humidity range 4%to 100%(condensing) Configurable to support a wide range DC connector type StSubli MC4 Connect PV modules quickly and easily I08 Series Microinverters are UL Listed of grid profiles Dimensions(H x W•D);Weight 212 mm(8.3")•175 min(6.9").30.2 mm(1.2");1.1 kg(2.43lbs) to the IQ8 Series Microinverters that have as PV rapid shutdown equipment and Meets CA Rule 21(UL 1741-SA)and IEEE Cooling Natural convection-no fans integrated MC4 connectors. conforms with various regulations when 1547:2018(UL 1741-SB) Approved for wet locations;Pollution degree Yes:PD3 installed according to the manufacturer's instructions. NOTE: Enclosure Class II double-insulated,corrosion-resistant polymeric enclosure 108 Microinverters cannot be mixed togetherwl:h Environ.category;UV exposure rating NEMA Type 6;outdoor previous generatieru of Erphase microinverters 0(17 Series.IQ6 series,etelntnerimesystem., DRAWN BY RG •Meets UL 1741 only when Installed with 10 System Controller 2 and 3. IQ Gateway is required to change the default grid CA Rule 21(UL 1741-54 UL 62109-1,IEEE 1547:2018(UL 1741-SB),FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 profile at the time of installation to meet the lore) Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017.NEC 2020,and NEC 2023 section 690.12 and DATE 10/24/2025 Authority Having Jurisciction(ARX requirements. C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturers instructions. l 2023 Enphase Energy.All rights nucrvcd.Enphasa the o and CC logo,.IQ and certain other marks listed at (1)No enforced DC/AC ratio. REVISION httrv-://emhasccom/vademark-uuoo-auidnHnce arc trademarks of Enphaso Energy,Inc.in the US and other countries. (2)Nominal voltage range can be extended beyond nominal it requvec by the utility. Data subject to change. IOBMC-MC4-DSH-00049-3.0-EN-US-2023-10-18 (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQBMC-MC4-DSH-00049-3.0-EN-US-2023-10-10 SIGNATURE PV-6.1 RESOURCE DOCUMENT CONTRACTOR mr-�-7 ELEMENT L-1 In EN RGY SOLARI BATTERY BACKUP 1631.779.79931 E2SYS.COM ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11962, USA, +1 631 760 7262 LIC TYPE: HOME ENPHASE. IQ Combiner 5/5C IMPROVEMENT, MASTER . Cu:uunp4'w,nru:,itsning Ci(CT-200-CLAMP) Apair of200A ulamprolyla u'.ure,n ualnftxmusbi,chaded Cool,d,e lnx 10 Battery metering CT 2C0 A clamp-styledurtem transfonnerforlO Battery metering.inciuced with the box ELECTRICIAN IQ Combiner 5 with IQ Gateway printed circuit board for integrated revenue-grade PV-=-=----=`% - ,rpducbon metarig;ANSI C12.2O•O.5%).coreamptio7 moitcnig(15%).and lQ r. LIC NO.: 67461-HI, TA IQ10-AMI er5 Battery—norm (2.5%),Inc udasasllver soles hi,ldtodenect heat. 52689-ME ' (%-10-AM1-2A0-5/X-10-AM1-.40-5-HO%) g Dimensions(V✓•H•D) Heir an•495 an•i6.d era U4.75-•19.5'•brackets IQ-AMl--k-S-HDK kletud 11IF. ceraseaess and Replkh acement P.-etii.e.th the Height era(21.0u')with mounting brnckeb. ' y£4cHA5E � mrmrir Maakwrs rrwnurmad In IF.Accessories and Replacement Party sw:tian. 9 9 Weight 75 kg(16.5lb) IQ Combiner 5C vAth IQ Gateway printedcircult board forintegratec revenue-grade PV production-Wring(ANSI 012.20 s0.596),consumption monitoring L2.596),and Ambient temperature range -4O•C to 46•C(-40'F to 115T) 10 Core it-SC IQ Battery monitorin0(1,SX,1.Includes Enphese Mobil.Connect cellular modem B PROJECT INFO&ADDRESS (X-10-AMI-240-5C/X-10-AMI-240-SC-HDK) (CELLMODEM-MI -SP-05)'.Includes a silver solar shield to deflect heat. Coobn Natural convection plus heatshiald 10-AMI-24C-5C-HDK Includes a factory installed hold-down kit comeatible Mth all the Enclosure environmental rating Outdoor,NRTL-certified,NEMA Vfpe 3R.polycarbonate eonetn,etion tuft breakers mentioned In tha Accessories and Replacement Parts section. pu pperco DEBRA CORITSIDIS WHAT'S IN THE BOX - 20dto SOA breaker in ts:ld to4]WG eo rductors 60A oreaker branch inpur_4 to 1/0 AWG capper conductors IO Gatewayisthepia:fwmfortotalenag/management k+comPrehens!ve.remove Wse sues - Mutraladgr combined.14 to 10coper AWG coed-tpe"ewduetors 1800 CEDAR BEACH RD X-IQ-AMl-240-5-HDK !Q Gateway printed circuit board maintenance,and Z-Or ew,of the EnPhese Ene,gy5ystem Neutral and ground:odernectcements fnduetou , X-IQ-AM7-240-SC-HDK Always foirowlccalcode requuemenrs for corduetor sung SOUTHOLD�;, X-IQ-AMl-240-5 Bar 80 A buslaw w support fo'one IQ Gateyray breaker and four 20 A breakers for Built-in CTRL beard for wired communication with the lO Battery So and the k `:-+g«= X-IQ-AM}240-$C ,Q Gateway beaker Circuit breaker.2pole,iD A/IS A mnve k-Iliny IQ 5,tes Mia c'a-1-end IQ Salter y 5P Go-uniation(in-premise ccnnecduit) IQS Y vacant Controller 3/3G.Irdegrated power Site communication for lO Series6-6 NY 11971, USA Micrters. ?odugtron CT Pre-wired revenue-O,ade sclidcore CT.accurate up to-05% Attitude Up to2600 meters(8.530 feet) IQCombiner 5/5C ConsumPus,CT Two consumption metering ctamp CTs.skppedwlththe box.accurate uptcs25% SYSTEM SIZE Smart bBattery CT Oneleattery mste,in I- CT.shpped with the box.accarare up tos25% 802.Tlb/g/o idual band 2.4GHz/S GH2)forconnectirg the Enphase Cloud through Tre IQ 9d'^tP hltegraedYY-Fi ihefn:emm. DC SIZE: 9.460 KW DC-(STC) socem es 10Sr5/SCcarrim-tern imerco nelGateway equipment ty prto single a conswe ist- Inciudesleation 2yfor Control board for wind corrmuiicaticn with lO System Crntreller 3/3G and the sbeamiinesl05edes Mioomverters and lQ Gateway instal:ation by prov:diryaconsisten:. communiaUon and control CTRL toartl 10 Battery SP W Fi range(recommended) 10m(328feeU pre-mealsoluion ban forresidentialappbcalt ns.QCombmwbibCusmw!redc-not •Includes Enphase Mobile Connect AC SIZE: 7.040 KW AC communication and cpatibie with lO System Contmller 3130 and 10 Battery 5P. (CELLMODEM-MI-06-5?-05).only Enphase Mob Connect(only with lO Combiner SC) 4G-based LTE-M1 cellularmodem(CELLMOCEM-M1-06-SP-O5)Mth a 5-year T-Mob'Je Bluetooth BLE42.10mrangetoconfiqu, Wr-FISSID The lO Combiner 5/SC.IQ Series Microin.ertars,10 System Controller 3/3G.and withloc-bi-SC da,aplan Ethernet Opt!on m al.802.3,CetSElot Cat fi)U)P Ethee'cable(net Included)for connecting to the IQ Banwy 5P pro0dea Complete grid-agnostic Enphase Energy System. Supports flexible networking W R. Accessories Mt Spare control headers for the COMMS-Kli-2 boas Enphase Cloud through rheilxernet. Ethernet,or cellular CELLMODEM-MI-06-SP-05 or CELLMODEM-MI-O6-AT-05(in--ludedwRh the L , , INCLUDED,ORDER Ca!kdar/Mohi:e Connect IQCombrmr5C) •Ptoyides productionand CELLMOOEM-MI-O6--SP-05 4G-baxdLTE-Ml cellular modem witha5-year T-M.obi'.e data pirn (revemre Bade)and Corsumpton Digital V0 Digital input/output for grd operator mntml monitoring CELLMOCEM-Ml-O6-AT-05 4G-based LTE-MI cellular modem with a 5-yestr AT&T data plan Mobile Connect COMMS-KIT-01 for 10 Battery 3/3TJIOAOT.COMMS-KIT-02 for Suppers Farm RR2X)LSievers 02XX,-dGE/ABB THOL21XX Swiss circuit brake,, US020 tO Battery 5P Earyfoinstall Circuit brcakers(oif-the-sfeif; (X%,ep-tras 10.15.20.30.40,50.a-60).Also supports Eaton BR220B,BR230B.ard Forconn-c Ion between true lO Gateway and a mobile device runnbg the •Meumatoonestudwithcemered 6R24OBci,cuit breakerscompatible with thehold-down kit. Access po nt TAP)mode IQ Series Miooinvenlers IQ System Ys Controller 3/3G brackets hase hsstaller AP The high-powered smart grid-ready 10 Series P,oriors necrogrid lnterednrwctlon..I- Circuit breakers( ovioedb En hose) RRK-lOA-2-240V BRK-15A-2-240V.BRK-:OA-2P-24OV,RRK-15A-2P-24OV-R,and Microh,ertors(106,107.and 103 Son-) (MID)fu,000nalhy by automatically detecting pr y p Mcmirg ports Up to two ConsumpGoi CTs.acre IQ Battery CT,and cite production CT •Supports bottom,ba_k.and side 6RK-204-2P-24OJ-B(more details in cite'Aszso:ies'section) -rafythninctailarimryorscc grid failures ard saomlea(y t rensitioning conduit entries Powarknecommunictrunn 9C-I10 kNz the home energyTi XA-50'J+R5I VELD-ES Repacement solar shield for lD Canbne,5/SC system item dpowet to Supbis for24 four 2lug-i Weak Web APi Seelctpsl/dewloPes-v4armha�econl Oaekup porrer rirwRs for240 VAC plug-in breakers XA-ENV2-PCBA-5 IQ Gateway reolaeemenf printed circuit board(PCB)fee lO Comtinw 5/5C r' (notincluded) Kill-N4-MD-25] Ho!c-down kit compatible with Eaton BR-3 Series circuit b-saters(with screws).Not LocaIAPI SesGlxriziv localAP1 _-J• =_.. I � 80Atotal PV branch circuits required fo•Xill-AM7-260-5-hDKiX�O-AMi-240-SC-HDK I.. .. FaclorY installed hold-down kit XA-COMMS2-PCBA-5� FaptacemmtCOMMS-KlT-2prfntedcicuitboard(PCB)fc IOCombinw5/5C�.� UL 1741,CAWCSA C222 No.707.1,Title 47 CFF.part 15,Class B.ICES 003, f•, Biuetooth-bened Wi-Fi pro,momng ELECTRICAL SPECIFICATIONS IQ Combiner with IQ Gateway MOM-208-SCFI-2016.UL 61010-1.CANICEA=2 No.61010-1.IEEE 1547:2018 O.A.1741-SB, for easy Wi-Fisetup ard Ed.1,IEEE 2030.SJGSIP CompliaM.Pmdnminn malwrinO:ANSI C1220acguracyclaca Rating 80 A 0.5(PV production) Reliable System vo!tace and frequency 120/240 VAC or 120/208 VAC.60 He lOBattery 5P 10 Load Controller Durable NHl L-certified NEMA type 311 Susbarrating 125A PV Mivohverters CO.107,and 103 Series MicrcinveRers F:llly integrated AC battery system Includes Helps prioritize essential appliances during re er,cioswn six field-replaceable 108D-13AT Mi-mir-ters. grid outage to optimize energy consumption Fa:At currant.1mg 10 kAiC IQ System Controller EP2000101-M240USDO and prolong battery Its. 5-yearirmi:edwarranry 2-ea labor reimbursement Maximum cvmaruaua wrlaM1ratu.y(v,putfiomPV/ 105ystam0ontealler2 EP200GIOT-M24OUS01 y program 64A COMMS-KIT-OP laded fcrlO Comtirrca etorago) — verage b1c ENCHARGE-3-IP-NA,ENCHARGE-ID-1D-N4,ENCHARGE-37-IRNA, 0.. SKUs- 103attary NOM ® Bra chcircuits(oar and/orsoragel IDG) r r2-poey0.Inc.Semen Oor GE AOB THQL Seriesd ributetl9enera on ENCHAHGIC24OL-NP L • k' -ULi-r4l listed (DG)oreake's only(nctln^-IudetO _ IQ System.Controller SC20DDRIC240US01,SC200GIIIC240U501 .� Maximum;otal branch circuit breaker rating SO A of dstnbutedgeneration/95 A with lO Gateway breaker urcluded COMMS-KIl-02' IQ Battery IOBa77ERY-SP-Ile-NA !0 Gateway breaker 10 A or 15 A rating GE/Siemens/Eaton Included 5-vear hmiled warranty Product-metenng CT 200 A solid core pre-rnstalled and-ad 1o10 Gateway 'For covrrbyspeo8c wanamy informacon,eee themtpr.//md,asaevnlmi SaYrasvarrx/r•rra:av Page _ R202aan�az Fm4✓42 ptes.eamvec.Emhax.1—aclrw.iGeMmnanmre ret.dar aP�✓i'.,ati�mrm•.er�nor arexv-.m 6•ar�mmu�y,ue0„a..w mvtuvual� .+. y im.h...�.net-vn�JwWte - :� ••r V ml+m.re•.iesren r Lrry (e11War.a-ism as +gas<.•mU.e,Ue Jnrw erlmdwd. R, m•1 n., � .pryny rSraCmnmao-eq:§oeGmm COYr.GKii-02.� Wr-Wrnrav✓fr.4raaTuzmvaMm.are aaiam.rt•n1E2MwEruay,IxinmaUS.oMarrrrcaunaec ravaq'Jnrorna�pe. I(]4-�N:-D]n-WUUI-tiL-Fn-4�-2e2a-NY: IU4>X,-Uyit„ua]It.U-Fit u5•U!a otl-J] it]G}:a,-->NLUUJ/-afY[Y W-.'ULa-Cy-.W DRAWN BY RG DATE 10/24/2025 REVISION SIGNATURE PV-6.2 RESOURCE DOCUMENT CONTRACTOR M ELEMENT ENERGY SOLARI BATTERY BACKUPI531.779.79931 E2SYS.COM AML IRONRIDGE AIRE RAIL Al Rails ELEMENT ENERGY LLC Aire1m Al Rail AireT'"A2 Rail AireT'"Rail Ties AireTM'DockT'" 7470 SOUND AVE, MATTITUCK, NY 11952, USA, 1 - +1 631 760 7262 LIC TYPE: HOME MW IMPROVEMENT, MASTER ELECTRICIAN The lighter,open AireTM The tougher,open AireT" Structurally connect and Connects AireT1A Rails to LIC NO.: 67461-HI rail for standard conditions. rail for higher load capacity. bond Aire" Rails together. attachments with ease. ' • 6'spanning capability 8'spanning capability Reinstallable,up to 5x Clicks on,slides easily 52689-ME • Wire management tray Wire management tray Internal splice design Drops into open slots • Mill or anodized black Mill or anodized black No more splice rules Anodized assembly PROJECT INFO&ADDRESS Clamps&Grounding DEBRA CORITSIDIS Aire""Lock Mids Aire"" Lock Ends AireT"" Lock StealthT'" Aire"" Lug 1800 CEDAR BEACH RDSOUTHOLD, ITEM NO DESCRIPTION QTY IN KIT 1 Aire Rail, Al, Black(or Clear), 170 1 4916 =41111111116 NY 11971, USA SYSTEM SIZE DC SIZE: 9.460 KW DC-(STC) AC SIZE: 7.040 KW AC Part Number Description Securely bond between Securely bond modules to Securely bonds modules to Bonds Aire TM Rails to modules to AireTM Rails. Aire TM Rails along ends. rail ends,entirely hidden. grounding conductors. AE-Al-170B AIRE RAIL, Al, BLACK, 170 Fits 30-40mm modules Fits 30-40mm modules Angled for easy install Simplified with single bolt AE-Al-170M AIRE RAIL, Al, MILL, 170 Utilizes UFOO design Easy rail engagement Robust tether leash Low-profile form factor • Minimal 1/2"gap Clean aesthetics Fits most modules Works with 10-6 AWG 1)Aire Al Accessories 4 AireTM Caps Aire'Clip AireTM MLPE Mount AireTTM All Tile Hook 0� .17�r 111 ry 170 .y 1.38 1.70 1.04 Block entry and provide a Keeps wiring contained in Securely bonds MLPE and Attaches rails to tile roofs, 0.22 finished look to Aire TM Rails. open Aire TM Rail channels. accessories to AireT" Rails. with AireT" Dock included. • Stay secure on rail ends No module interference Glove-friendly installation Works on flat,S,&W tiles • Symmetrical,with drain Simple press-in design Lays flush in rail channel Single-socket installation • Cover rough-cut ends Slot for easy removal Low profile form factor Optional deck flashing Resources Part Number Material Value Design Assistant ;.Bo o,v,g, , Approved for FL Hurricane Zones AE-Al-170B 6000-Series Aluminum Black — - - e ° + " Quickl o from rou h la out '* '° *% AireTM has Florida Product Approval.y g g y � a�' pp DRAWN BY RG to fully engineered system. =o * = Additional details can be found on the AE-Al-170M 6000-Series Aluminum Clear Florida Building Code website. vto - Go to lronRidge.com/design r� °a°, 9 DATE 10/24/2025 Learn More at bitty/florida-aire REVISION SIGNATURE PV-6.3 RESOURCE DOCUMENT CONTRACTOR �� ® ELEMENT ENERGY BGLARI BATTERY BACKUP1631.779.79931 E25Y5.C13M IRONRIDGE Bonding Hardware A'.�.�lit�. IRONRIDGE Grounding Lug ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11952, USA, +1 631 760 7262 3 3 LIC TYPE: HOME 2 1 IMPROVEMENT, MASTER 1 3 ELECTRICIAN JIn ® ® 2 LIC NO.: 67461-1-1I, 52689-ME ITEM NO. DESCRIPTION 1 BOLT,T CSTM,3/8-16 4 PROJECT INFO 8 ADDRESS 2 BOLT,BONDING 3/8-16 SQ HEAD ITEM NO. DESCRIPTION DEBRA CORITSIDIS 3 NUT, BONDING STEP 1 LUG,GROUNDING,LAY-IN-LOW PROFILE 1800 CEDAR BEACH RD, 2 BOLT, 1/4-28 X.750"HEX CS SST SOUTHOLD, BONDING HARDWARE 3 NUT,FLANGE HEX 1/4-20 SST NY 11971, USA 4 BOLT,T CSTM 1/4-20 X 1.188"LOCK SS Part Number Description SYSTEM SIZE BHW-TB-02-Al T-BOLT,BONDING HARDWARE Part Number Description Wire Size Range(AWG) DC SIZE: 9.460 KW DC-(STC) AC SIZE: 7.040 KW AC BHW-SQ-02-Al SQUARE-BOLT,BONDING HARDWARE XR-LUG-03-Al GROUNDING LUG,LOW PROFILE 4-10 1) BOLT, T CSTM, 3/8-16 2) BOLT, BONDING 3/8-16 SQ HEAD 1)Lug, Grounding 3) Nut, Flange Hex 1/4-20 .82 1.00 1.00 3/8-16THD 63 .63.71 1/4-20THD 0.59 .38 � .56 ® 4 ae �.1�-7 �r� 29 T .24 I 0.26 7116"Head - I 23/8-i 6 TH 1.75 Property Value Property Value Property Value Property Value Material 300 Series Stainless Steel Material 300 Series Stainless Steel Material 300 Series Stainless Steel Finish Clear Finish Clear Finish Clear Material I Tin Plated Copper Finish I Clear Matte 4) Bolt,T CSTM 1/4-20 x.750 3) NUT, BONDING STEP —L .24_� �_' 1/4-20THD �3/8-16 THD 2) Bolt, 1/4-28x.750 IHex � � �.75 ® 011, f H lad -►i L-.16 1/a28THD 61 .75 �- (`Jl .75 �- 26 7/16"Head .16 79 Property Value Property Value Property Value Material 300 Series Stainless Steel Material 300 Series Stainless Steel Material 300 Series Stainless Steel Finish Clear Finish Clear DRAWN BY RG Finish Clear Y1•30 Y1.10 DATE 10/24/2025 REVISION SIGNATURE PV-6.4 RESOURCE DOCUMENT CONTRACTOR LEMENT EJ ® ENERGY EULARI BATTERY SACKUP1531.779.79931 E25YS.C13M Adak IRONRIDGE End Fastening versa en Object ZAk IRONRIDGE Universal Fastening Ob'ectO ELEMENT ENERGY LLC g 7470 SOUND AVE, Only for installation and use with lronRidge products in MATTITUCK, NY 11962, accord with written instructions see IronRidge.colnlUFO USA, +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER a ELECTRICIAN LIC NO.: 67461-1-1I, 52689-ME PROJECT INFO&ADDRESS UNIVERSAL FASTENING OBJECT$ DEBRA CORITSIDIS PART NO. DESCRIPTION 1800 CEDAR BEACH RD, UFO-END-01-Al END FASTENING OBJECT(END CLAMP,30-40mm),MILL SOUTHOLD, UFO-END-01-B1 END FASTENING OBJECT(END CLAMP,30-40mm),BLACK NY 11971, USA SYSTEM SIZE 1 .43 1.0 ITEM NO. DESCRIPTION DC SIZE: 9.460 KW DC-(STC) UFO-CL-01-Al UNIVERSAL MODULE CLAMP, CLEAR AC SIZE: 7.040 KW AC 39 UFO-CL-01-Bl UNIVERSAL MODULE CLAMP, BLACK 1.27 COMPATIBLE WITH .58 30-40mm MODULE FRAMES 2 .29 7/16'Hecd - .61 I 25 COMPATIBLE WITH C�.37 30-46mm MODULE FRAMES 1.0 01.12 7/16"HEAD 97 i0y .25 Property Value ITEM NO. MATERIAL FINISH Materia! 300 Series Stainless Steel 1 6000 SERIES ALUMINUM MILL OR BLACK Finish Clear and Black 2 300 SERIES STAINLESS STEEL CLEAR AND BLACK DRAWN BY RG °'° v132 DATE 10/24/2025 REVISION SIGNATURE PV-6.5 RESOURCE DOCUMENT CONTRACTOR ELEMENT ENERGY 9OLARI BATTERY BACKUP 1631.779.79931 E2SYS.COM AaL IRONRIDGE UFO® Family of Components System Diagram ELEMENT ENERGY LLC 7470 SOUND AVE, - - - - MATTITUCK, NY 11952, Simplified Grounding for Every Application _ _ _ _ _ _ _ _ _ _ _ USA, �- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - '' +1 631 760 7262 The UFO®family of components eliminates the need for LIC TYPE: HOME separate grounding hardware by bonding solar modules ■� , IMPROVEMENT, MASTER directly to IronRidge°XR Rails®.All system types that = ELECTRICIAN feature the UFO"family—Flush Mount',Tilt Mount®and Ground Mount®—are fully listed to the UL2703 standard. g LIC NO.: 67461-1-1I, - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - 62689-ME UFO°hardware forms secure electrical bonds with both the - - - - - - _m- -- - - - - -- , module and the rail,resulting in many parallel grounding _ PROJECT INFO 8 ADDRESS paths throughout the system.This leads to safer and more reliable installations. DEBRA CORITSIDIS Only for installation and use with IronRidge products in accord with - - - = - - - - - - - - - -m_ - - - - - - - - - - - - - - - - - - 1800 CEDAR BEACH RD, written instructions.See IronRidge.com/UFO $OUTHOLD, NY 11971, USA Universal Fastening Object(UFO ) Stopper Sleeve The UFOID securely bonds solar modules to XR SYSTEM SIZE The Stopper Sleeve snaps Rails°.It comes assembled and lubricated,and _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ DC SIZE: 9.460 KW DC-(STC) onto the UFO®,converting it can fit a wide range of module heights. AC SIZE: 7.040 KW AC— — — --- — — — — — — — — — — — I into a bonded end clamp. Q UFO 01 Stopper Sleeve • Grounding Lug m BOSS" Splice Ground Wire 4 Approved Enphase microinverters can provide equipment grounding of IronRidge systems,eliminating the need for tea _ Y grounding lugs and field installed equipment ground conductors(EGC).A minimum of two microinverters mounted to the LL same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. UL Certification ystem o The IronRidge°Flush Mount, r Tilt Mountd Ground Mount ��i ! ';i�l . ,an roun ou XR Rails ./ d XR100&XR1000 - i---- BOSS®Splice l '� �� ; Systems have been listed to UL -- Bonded SVuctural Splice r' / 2703 by Intertek Group plc. UFO/Stopper connects rails with built-in L �i bonding teeth.No tools or �n, BOSS°Splice d d NIA hardware needed. UL 2703 is the standard for evaluating solar mounting Grounding Lugs 1 per Row 1 per Row 1 per Array systems. It ensures these devices Microinverters GroundingLug will maintain strong electrical and &Power Compatible with most MLPE manufacturers. g A single Grounding Lug Bonded Attachments mechanical connections over Optimizers Refer to system installation manual. "�✓� .-.�� an extended period of time in connects an entire row The bonding bolt attaches Fire Rating Class A Class A NIA of PV modules to the and bonds the L-food to the extreme outdoor environments. g DRAWN BY RG grounding conductor. rail.It is installed with the same socket as the rest of the Modules Tested or Evaluated with over 400 Framed Modules System. 0 Go to IronRidge.com/UFO Refer to installation manuals for a detailed list. DATE 10/24/2025 REVISION SIGNATURE PV-6.6 RESOURCE DOCUMENT CONTRACTOR INELEMENT ENERGY BCLARI BATTERY BACKUP1631.779.79931 E20YS.COM ZA�. IRONRIDGE QuickMount® Halo UltraGrip® ELEMENTENERGY LLC 1.Halo UltraGrip 38 0 SOUND AVE,AVE MATTITUCK, NY 11952, USA, +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN LIC Iii 67461-HI, RD STRUCTURAL SCREW PN RD-1430-01-M1 3.35 52689-ME SOLD SEPARATELY SHOWN FOR REFERENCE PROJECT INFO 8 ADDRESS DEBRA CORITSIDIS 1800 CEDAR BEACH RD, Release Liner SOUTHOLD, shown for reference NY 11971, USA 3.83 SYSTEM SIZE o 0 DC SIZE: 9.460 KW DC-(STC) 0 -- .40 AC SIZE: 7.040 KW AC 0.26 -I— O 1.63 1.56 I ITEM NO DESCRIPTION QTY 1N KIT -}- 1 QM Halo UltraGrip(Mill or Black) 1 O .34 PART NUMBER DESCRIPTION QM-HUG-01-M1 Halo UltraGrip-Mill CIL QM-HUG-01-B1 Halo UltraGrip-Black --- — 3.00 Property Value Material 300 Series Aluminium DRAWN BY RG Finish Mill or Black DATE 10/24/2025 ©2023lronRidge,Inc.All rights reserved.Visit x".ir-patenls.com for patent information. ON-HUG-01-131 or QM-HUG-01-Mt Cut Sheet Rev 1.01 02023 IronRidge.Inc.All righ5 reserved.Visit w .ir-patenlsmm for patent information. QM-HUG-01-B1 orCWHUG-01-Ml Cut Sheet Rev 1.01 REVISION SIGNATURE PV-6.7 RESOURCE DOCUMENT CONTRACTOR ELEMENT 12� IRONRIDGE QuickMount" RD Structural Screw 5OlARl B0 ® ENERGY ATTERY BACKUP1631.779.79931 E25YS.COM ELEMENT ENERGY LLC 7470 SOUND AVE, n MATTITUCK, NY 11952, USA, +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN LIC NO.: 67461-HI, 52689-ME PROJECT INFO&ADDRESS DEBRA CORITSIDIS ITEM NO DESCRIPTION QTY IN KIT 1800 CEDAR BEACH RD, 1 Self Drilling Screw,#14,Wood Tip 1 SOUTHOLD, 2 Washer, EPDM Backed 1 NY 11971, USA SYSTEM SIZE PART NUMBER DESCRIPTION DC SIZE: 9.460 KW DC-(STC) HW-RD1430-01-M1 RD Structural Screw AC SIZE: 7.040 KW AC 1.Self Drilling Screw,#14,Wood Tip 22 #14 DIA 5/1 t5" Head 0.43 i77!77 Property Value Material 300 Series Stainless Steel Finish Clear 2.Washer,EPDM Backed 0M.26 0.57 .13 DRAWN BY RG Property Value DATE 10/24/2025 Material 300 Series Stainless Steel REVISION Finish Clear SIGNATURE •c 2022 Iron Ridge,Inc.All rights reserved.Visit www.ir-patents.com for patent information. QM-HW-RD-143D-01-M1 Cut Sheet Rev 1.2 PV-6.8 RESOURCE DOCUMENT CONTRACTOR LA ® ELEMENT ENERGY BCLARI BATTERY BACKUP[631.779.79931 E2SYS.00M CERTIFICATE OF COMPLIANCE CERTIFICATE OF COMPLIANCE ELEMENT ENERGY LLC 7470 SOUND AVE, Certificate Number 20230825-E341165 SB' Certificate Number 20230825-E341165 SB MATTITUCK, NY 11952,USA, Report Reference E341165-20210317 Report Reference E341165-20210317 +1 631 760 7262 Date 2023-09-27 Date 2023-09-27 LIC TYPE: HOME This is to certify that representative samples of the product as specified on this IMPROVEMENT, MASTER Issued to: Enphase Energy Inc. certificate were tested according to the current UL requirements. ELECTRICIAN' 1420 N.McDowell Blvd. Petaluma, CA 94954-6515 Standards for Safety: LIC NO.: 67461-HI, This is to certifythat Photovoltaic Grid Support Utility Interactive Inverter with Rapid This is to certify that representative samples of the product as specified on this 52689-ME PP Y P� fY P P P P representative samples of Shutdown Functionality certificate were tested according to the current UL requirements,Standards for Safety: Models: IQ8-60, IQ8PLUS-72,IQ8M-72, IQ8A-72, IQ8H-208-72, PROJECT INFO&ADDRESS I1081-1-240-72, may be f/b-2,-5,-E or-M,may be f/b-ACM,f/b- UL 1741, Inverters,Converters,Controllers and Interconnection System Equipment for Use US,may be f/b-NM, may be f/b-RMA,may be f/b-&,where"W With Distributed Energy Resources,Edition 3, Issue Date 05119/2023. Including the DEBRA CORITSIDIS designates additional characters. requirements in UL 1741 Supplement SA and SB. 1800 CEDAR BEACH RD, Models IQ8HC-72, 1Q8AC-72, IQ8MC-7]may be f/b-2,-5,-E or- IEEE 1547, Interconnection and Interoperability of Distributed Energy Resources(DERs)with SOUTHOLD, M,may be f/b-ACM,f/b-US, may be f/b-NM,may be f/b-RMA, Associated Electric Power Systems(EPSs)Interfaces, Issue Date 02/15/2018 NY 11971, USA may be f/b-&,where"W designates additional characters. IEEE 1547.1, IEEE Standard Conformance Test Procedures for Interconnecting Distributed SYSTEM SIZE Model IQ8X-80 may be f/b-2,-5,-E,or-M, may be f/b-ACM,f/b- Energy Resources(DERs)with Electric Power Systems(EPSs)Associated Interfaces, Issue DC SIZE: 9.460 KW DC-(STC) US,may be f/b-NM, may be f/b-RMA,may be f/b-&,where"W Date 03/05/2020. AC SIZE: 7.040 KW AC designates additional characters CSA C22.2 No. 107.1-16,General Use Power Supplies, Edition 4, Issue Date 0612016 Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. 0 R21:The evaluation to the.Standards above,provides evidence of compliance to the intent of the existing California Rule 21 Interconnection(references to the past publication Standard(s)for Safety: See Page 2 of IEEE 1547 standards)and UL1741Table SA1.1 option to use the IEEE 1547.1-2020 and UL1741SB test methods in conjunction with using IEEE 1547-2018 as the SRD Additional Information: See the UL Online Certifications Directory at under which SA11.2 Normal Ramp Rate is not address.Additional testing was conducted www_ul.com/database for additional information to confirmed compliance to Normal Ramp Rate SA11.2 This Certificate of Compliance does not provide authorization to apply the UL Mark.Only the UL 14H(SA):The evaluation to the Standards above provides evidence of compliance to Follow-Up Services Procedure provides authorization to apply the UL Mark. HECO Rule 14H,SRD V1.0, Interconnection Application. Only those products bearing the UL Mark should be considered as being UL Certified and x❑ 14H(SB):The evaluation to the Standards above provides evidence of compliance to covered under UL's Follow-Up Services. HECO Rule 14H,SRD V2.0, Interconnection Application. Look for the UL Certification Mark on the product. Any information and documentation involving UL Mark services are provided on behalf of UL LLC(UL)or any authorized licensee of UL. Bruce MahreMols,Director North American Certification Program Bruce Mohrenholz,Director North American CaNhcatlon program DRAWN BY RG UL LLC UL LLC Any hdmmation and doeunentation Involving UL stark services are provided on behalf of UL LLC(UL)or any authorized licensee of UL For questions.please Any Information and documentation Involving UL Mark services an,provided on h of UL UL LLC(UL)or any sulhadead licensee of UL For pres[lons,please DATE 10/24/2025 eentecta loW UL Customer Servtoe Reprasenmtive a.k0ld.mm�l W eentact a Inlet UL Cu .,SeMce ReprosentatIve on herolhdmNaEmd.M.-limey REVISION SIGNATURE PV-6.9 RESOURCE DOCUMENT