HomeMy WebLinkAbout52860-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52860 Date: 04/14/2026 Permission is hereby granted to: Breeze Hill Partners LLC 85 Perry St New York, NY 10014 To: Install commercial kitchen fire suppression system and hood and duct exhaust system in existing commercial building as applied for. Premises Located at: 31215 CR 48, Peconic, NY 11958 SCTM#74.-1-36 Pursuant to application dated 03/31/2026 and approved by the Building Inspector. To expire on 04/13/2028. Contractors: Required Inspections: Fees: Exhaust Hood and/or Fire Suppression System $300.00 Exhaust Hood and/or Fire Suppression System $300.00 CO Commercial $100.00 Total $700.00 Building Inspector TOWN OF SOUTHOLD—FIRE MARSHAL " Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-95021i�t //NVna���� S 'L1th()1.dto\y ,lao,� IRE .PROTECTION SYSTEM L IT Date Received APPLICATION 11 For Office Use Only 5��l(1 Building Inspectm.PERMIT NO. ..�.w �..__....._�......_._w�w_.........�........ Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted.WORK IS NO"I:"'TO' E s,rARTI+o'Jt prior to the approval of plans and issuance of a permit. Has a building permit been obtained for this project? ❑ Yes No If yes,building permit# Date: cy d lea PROJECT INORMATION: Project Address: �j t J 15 COJ P'd LI K SCTM# 1000- -7 —3 City: C C OCR /�' tic 5 Zip: CONTACT PERSON INFOR ATION: Name: AQe .. ("M ' 2L-G. QQ G t"Ci Mailing Address: 1-7 i q C�10t1 ; .,1 s - .. c)(( aoqL ALI114 Phone#: Email: .. Preferred contact method(select one): ❑Phone Email HT Fta,--.Cofv1 CONTRACTOR INFORMATION: Name: RbT - VkCw-N Contractor License#: i '1 Mailing Address: CKX6tm C � Phone#:(P31 I W'-Ll <'' Email: T Rate-COrYt SCOPE OF WORK-.- Occupancy Description: ❑ Asse ribly XBusiness ❑Education ❑Factory/Industrial ❑ Institutional ❑Mercantile ❑Residential ❑ Storage Description of Work:: ,. kcn � 'Wew System ❑ Existing System Modification Sprinkler/Standpipe/Water Supply Fire Alarm/CO Detection Systems Other Fire Protection Systems (Check all that apply) (Check all that apply) (Check all that apply) ❑NFPA 13,13D or 13R System ❑Manual ❑Automatic ❑ Smoke Control ❑Standpipe ❑ Fire Pump ❑Protected Premises (local) ❑ Wet or Dry Chemical/Clean []Supervising station Agent Number of sprinkler heads. ❑Central Station Kitchen hood/exhaust ❑ Other Floor Area(sq. ft.). A ❑ Check Box AfterReading- I,the undersigned,understand that the issuance of a permit for the type which is herein applied for is based on the agreement to conform to all regulations and requirements.I further understand that non-compliance of said requirements,by myself or any officer or employee of the firm or individual listed as the applicant on this form,shall be cause for revocation of said permit.Upon revocation of said permit the applicant or any employee of the applicant shall be prohibited to conduct such work for which this permit was issued.The reissuance of a permit shall be based upon review of the circumstances leading to the revocation.Any false statement(s)made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the Penal Law Application Submitted By(print name): Authorized Agent ❑Owner _. ..�. .....{..... _.� _wwwLwww .. ...................... .._..mm................ � � Company(if applicable): lrf��(ln���tc� _www._w.w_______ ._ Date: Applicant Signature. FIRE PROTECTION SYSTEM PERMIT APPLICATION SUBMITAL INSTRUCTIONS Submit application only after reviewing the requirements for the specific permit for which you are applying(click the applicable link below). FIRE ALA /CARBON MONOXIDE DETECTION SYSTEM SUBMITTAL GUIDELINES FIRE SPRINKLER SYS"I"E I SUBIVITTT, L GIJI EL NES * FIXED F'I'II,IR SIiPP h SSION HOOD& EXHAUST SYSTEMS SUBMITTAL GUIDELINES FEES A$250 permit fee is required for a non-residential permit.A$50 Certificate of Occupancy fee is required if the project is not part of an existing open building permit. All checks should be made payable to the Town of Southold. Permits,once issued,shall at all times be kept on the premises designated thereon with a copy of approved drawings and all related documentation required to obtain said permit.Installations subject to final testing,inspection and approval.Arrangements for testing/inspection shall be made by contacting the Town of Southold Building Department(631)765-1802. FOR OFFICE USE ONLY Amount Paid: Check No.: FM: Permit No.: Date: Exp.Date: 2 GRAINCTER. flip, product Categories HVAC and Refrigeration Ventilation Equipment Ventilation Fans Roof&,Attic Ventilation Fans Upblast Exhaust Fans ,entrifugal Upblast Exhaust Fans Centrifugal Upblast Roof Exhaust Fan Centrifugal Upblast Roof Exhaust Your Price Fan: Belt Drive, Includes Drive Pack, 16 1/2 in Wheel, 3,996 cfm This item requires special shipping,additional Item 7A626 Mfr.Model 7A626 charges may apply. No image available mww"111111;1 Setup Auto Reorder # Ship Pickup Expected to arrive by end of May,2026. Product Details Catalog Page 2826 Ship to'117411 ( Change )rand DAYTON Shipping Weight 97.3 lbs Ship Availability Terms :or Air Type Kitchen Air )rive Type Belt Drive Add to List 4ssembly Unassembled Add to Quote ncludes Drive Package with Motor Yes Nheel Diameter 16-1/2 in Alternate Products G� 7_xhaust Airflow @ 0.000 in SP 3,996 cfm Exhaust Airflow @ 0.125 in SP 3,901 cfm Exhaust Airflow @ 0.250 in SP 3,806 cfm Centriftigal Upblast Roof Exhaust Fan:Belt Drive,Includes Drive Exhaust Airflow @ 0.375 in SP 3,698 cfm Pack,"I 81/2 in Wheel,4,477 cfm Exhaust Airflow @ 0.500 in SP 3,584 cfm Item 7A630 Maximum Static Pressure 1-1/2 in we Your Price :or High-Static Pressure Applications No oty 14ameplate Voltage 11 5/208-230V AC Ade r -J, phase 1 :requency 60 Hz 'urrent 12.8/6.4 to 6.4 A Centrifugal Upblast Roof Exhaust Motor Horsepower 1 hp Fan:Belt Drive,Includes Drive Pack,18 1/2 in Wheel,4,477 cfm 3rake Horsepower 1-1/20 hp Item 7YR56 Motor Speed 1,390 RPM Your Price a, Maximum Fan Speed 1,390 RPM Vintrir Pnnlnzi Yro Onan nrinnrnnf 0 -iigh-Efficiency No =peed dontrollable No Vumber of Speeds 1 Nheel Type Backward Inclined !~!heel Material Aluminum -lousing Material Aluminum lousing Material Fabrication Spun Maximum Inlet Air Temperature 300°F 3ase Shape Square 3ase Height 1.8 in 3ase Width 26 in 3ase Length 26 in 3verall Height 28-1/8 in 'searing Type Sealed Pillow Block Damper Size 19 x 19 in Viounting Location Roof Mount Type Roof Curb application Industrial and Commercial Buildings;Restaurants;Schools Standards AMCA Sound and Air,UL/cUL 762 ncludes Drive Package;NEMA 1 Junction Box compatible Curb Grainger Part Number 2RB77;2ZV83;3C437;4C454;4HX40;4HX48;4HX56;4HX62 compatible Damper Grainger Part Number 4HX66 Sound Level 18.0 sones @ 1.500 in SP;18.6 sones @ 1.250 in SP;19.0 sones @ 1.000 in SP;19.2 sones @ 0.875 in 313;19.4 sones @ 0.750 in SP;19.6 sones @ 0.625 in SP;19.9 sones @ 0.500 in SP;20.0 sones @ ).375 in SP;21.0 sones @ 0.125 in SP;21.0 sones @ 0.250 in SP;22.0 sones @ 0.000 in SP =eatures kir Handling Quality Bearings Meet Minimum of L10-100,000 Hours;Nonoverloading Centrifugal Nheel Design JNSPSC 40101502 :ountry of Origin Varies(subject to change) product Description <itchen air belt-drive fans with drive help to ventilate a kitchen or similar environment with grease-laden )r humid air.These fans come with a drive package that includes a motor,sheaves,belts,and )ushings. Fans intended for use with heavy grease feature steel propellers and housings which are rosier to clean and are less reactive to cleaning chemicals. Belt-drive fans are typically quieter and provide more control over the fans'blade speed and airflow than direct-drive fans. Compatible Products x �rodvcl Categories HVAC and Refrigeration Ventilation Equipment Ventilation Fans Roof&Attic Ventilation Fans Uptilm exhaust ran$ 'entrifugal Upblast Exhaust Fans Centrifugal Upblast Roof Exhaust Fan Centrifugal Upblast Roof Exhaust Your Price Fan: Belt Drive, Includes Drive Pack, 16 1/2 in Wheel, 3,996 cfm This item requires special shipping,additional Item 7A626 Mfr.Model 7A626 charges may apply. No ir'nage available 01 Setup Auto Reorder FE] Pickup Expected to arrive by end of May,2026. Product Details Catalog Page 2826 Ship to'11741 I Change 3rand DAYTON Shipping Weight 97.3 lbs -ship Availability Terms :or Air Type Kitchen Air Drive Type Belt Drive Add to List .ssei ably Add to Quote Unassembled nc(udes Drive Package with Motor Yes 00 Nheel Diameter 16-1/2 in Alternate Products (ji Exhaust Airflow @ 0.000 in SP 3,996 cfm Exhaust Airflow @ 0.125 in SP 3,901 cfm Exhaust Airflow @ 0.250 in SP 3,806 cfm Centrifugal Upblast Roof Exhaust Fan:Beft Drive,Includes Drive Exhaust Airflow @ 0.375 in SP 3,698 cfm Pack,'l 8 1/2 in Wheel,4,4;77 cfm Exhaust Airflow @ 0.500 in SP 3,584 cfm Item 7A630 Maximum Static Pressure 1-1/2 in we Your Price :or High-Static Pressure Applications No Qty vameplate Voltage 11 5/208-230V AC kWd W Cag� :11hase 1 :requency 60 Hz 'urrent 12.8/6.4 to 6.4 A Centrifugal Upblast Roof Exhaust Motor Horsepower 1 hp Fan:Belt Drive,Includes Drive Pack,18 1/2 in Wheel,4,477 cfm Drake horsepower 1-1/20 hp Item 7YR56 Motor Speed 1,390 RPM Your Price Oil Maximum Fan Speed 1,390 RPM 1Antnr Pne-.in*iir=Onan nrinnrnnf @I �i h, fhc _.. _� Mxx .ur g iien� Motor No Speed Controllable No Vumber of Speeds 1 Nhee€Type Backward Inclined Nhee€Material Aluminum -iousing Material Aluminum -lousing Material Fabrication Spun Maximum Inlet Air Temperature 300"F Base Shape Square Base Height 1.8 in Base Width 26 in Base Length 26 in Jverall Height 28-1/8 in Bearing Type Sealed Pillow Block 3amper Size 19 x 19 in Mounting Location Roof Mount Type Roof Curb �ppliication Industrial and Commercial Buildings;Restaurants;Schools Standards AMCA Sound and Air;UUcUL 762 ncludes Drive Package;NEMA 1 Junction Box compatible Curb Grainger Part Number 2RB77;2ZV83;3C437;4C454;4HX40;4HX48;4HX56;4HX62 :ompatible Damper Grainger Part Number 4HX66 Sound Level 18.0 sones @ 1.500 in SP;18.6 sones @ 1.250 in SP;19.0 sones @ 1.000 in SP;19.2 sones @ 0.875 in 313;19.4 sones @ 0.750 in SP;19.6 sones @ 0.625 in SP;19.9 sones @ 0.500 in SP;20.0 sones @ 3.375 in SP;21.0 sones @ 0.125 in SP;21.0 sones @ 0.250 in SP;22.0 sones @ 0.000 in SP =eatures Air Handling Quality Bearings Meet Minimum of L10-100,000 Hours;Nonoverloading Centrifugal Nheel Design JNSPSC 40101502 :ountry of Origin Varies(subject to change) 3roduct Description (itchen air belt-drive fans with drive help to ventilate a kitchen or similar environment with grease-laden :)r humid air.These fans come with a drive package that includes a motor,sheaves,belts,and Bushings. Fans intended for use with heavy grease feature steel propellers and housings which are rosier to clean and are less reactive to cleaning chemicals.Belt-drive fans are typically quieter and provide more control over the fans'blade speed and airflow than direct-drive fans. Compatible Products Inr" Product Categories HVAC and Refrigeration / HVAC Controls and Thermostats / Process Thermostats / Cal-Stat Thermostat,Pipe Thread,Cartridge.Sh.. VULCAN K Cal-Stat Thermostat,Pipe Thread,Cartridge,Sheath Dia.1/2 in r Item#2E942 Mfr.Model#1 C2C9 ��� UNSPSC#41112209 Catalog Page#3065 Country of origin USA Country of Origin 1s subject to change. Add Extended Protection The Vulcan Calvctat provides reliable temperature control with a rugged,self Plan contained design and application versatility not available with many other mechanical for$37.50/each or solid state temperature controls.Insert into drilled holes or directly i View More v Plan Detods&Exchlalons Setup Auto Reorder Tap Image to zoom. Shipp%^ng Q Pickup Availability Expected to arrive Wed.Feb 24. Ship to 11741 1 Change Technical Specs Item CalStat Thermostat Contact Rating Restshwe @ h 20V 5 A Shipping Weight 0.2 lbs Ship AvallabaHy T.-, Thermostat Type Pipe Thread,Cartridge Contact Ral4ng ReslsMtve r j1240V 3 A Sheath Dla. 1/2 in Swhch Hal*gs @ 12OVDC 1 A Add to List Overall Length 3 1/4 in Conitol Range -100 Degrees to 600 Degrees F Insertion Depth 2 1/8 in D&iferwWa�p +/-1/2 Degrees F Thread NPT 3/8"18 For Use With Fryers and other Food Service Equipment and Replacement Switch Action Close on Rise Units Switch Type SPST Agency Compliance UL,CSA Number of Switches 1 M organ II I t Advanced MaterialsY F reMas er° Fas rap° XL iro uct Data and Iin t l0 ti n Guide nes r W �44 Product Description Thermal Ceramics FireMaster FastWrap XL is a flexible blanket poniposed of high temperature fibers classified for applications to 21921�,(12001C) and fully encapsulated in a durable glass fiber reinforced foil;facing for easy handling and installation. Thermal Ceramics FastWrap XL is UL and ULC Listed for 1 and 2 hour fire resistive enclosure protection„ zero clearance for kitchen exhaust ducts, electrical circuit QL)c protection, and`as a component in UL firestop designs for fire resistance rated floors, ceilings, and walls. LISTED The cofe fibers in FastWrap XL are manufactured using Thermal'Ceramics patented pSS1 Superwoole fiber which is an alkaline-earth silicate wool with low biopersistence � an therefore increased safety for installers. FastWrap XL is under UL's Fallow-Up Service Program to ensure the consistent quality essential to this life-safety applicaU0 L - tion. it Features or Benefits A lications pp 0 Thin and Lightweight at 1-1/2" (38mm)thick, 41 2 hour enclosure and firestop system for kitchen ex- 6 pcf(96 kg%m3)density haust duct + Contours easily to complex duct designs , Zero clearance to combustibles Grease duct installation UL and ULC Listed with butt + 1,2 and 3 hour enclosure and firestop system for joints at all seams on both layers ' hazardous exhaust ducts, pressurization ducts, clothes dryer exhaust ducts,trash and linen chutes, and other Fully foil encapsulated for fast and clean installation fire rated HVAC ducts « Contains 21921E (1200°C) rated fibers i• 1 hour electrical circuit integrity protection + Microbial Resistance validated by UL Environment r< Engineered and tested solutions for fire protection of +� Good sound absorption structural steel and storage vessels per ASTM E119, ISO 834, and UL1709 +► Compliant to IMC, NFPA 96, UMC, CIVIC, CNBC 0 marketing.tc@morganplc.com r r U more llreMas er Fasfflra .(L AdvancedMateriBISI Product Data and Installation Guidelines „ LW Specifications - Division 23 07 00 (or 150 0)1 11 Performance Specifications CSI Spec and AutoCAD available online, Reference •Stanwww•.•r•.•�• da ' -�µMm p Reference Standard Stan rd No.„Performahce www.arcat.com/sd/clients/thermcer.htmi. Grease Duct Enclosure System ASTM...".""""""""""""""", ..._..._...........• E2336 i Pass Thermal Ceramics Firelaster FastWrap XL is a flexible Section 16.1-Non-Combustibility ASTM E136 Pass high temperature insulation rated to 2162OF (1200*C)that Is ------- Section 16.2-Fire Resistance(wall) ASTM E119 Pass fully encapsulated in FSP facing.The duct enclosure _... _..__.. -__ system shall be listed by UL and/or ULC per ASTM F 2336, Section 16.3-Durability"Test ......,..,..,..,_ ASTM C518 i Passmmmmm� CANIULC S144 and ISO 6944 for 1- 2-and 3-hour on 16.4-Internal Fire Test ASTM E2336 Pass Section rating and zero clearance to combustibles, and tested per ASTI�I .wecti_. FU for a flame/smoke rating less than 25/ 0. Insulation' Section 16.5-Fire Engulfment(duct) ASTM E814/ Pass shall have a nominal thickness of 1-1/2 inches(38 mm)and _w �. E119 www _ww ULC Grease Duct Test pass density of 6 pcf(96 kg/m). Insulation shall have an P_"vr lue Protocol of'7.3 at *F, Installation shall be in strict accordance to w.ww... Fire _.................................. Standard Methods of Fire CAN/ULC WVYYWWWW WWWW_. manufacturer's published installation instructions„ UL or a Resistance Tests-Grease Duct As- S144 Pass ULC Listings,and shop drawings. semblies _... Grease Duct"Clearances —UL 1978 Pass Physical Properties Ventilation....................................�..Enclosure ISO 6944 Pass .............. Duct Enclosure y ..._......... .,,.....,.,. w.._.... Air w. -_............ -µ__._. .w_-_.._.. Product Unit Size g Characteristics ATM E84 <25/50 9 Surface Burning Charact S S _ --.... __- Units/ Wei ht/ i Carton Carton,llh ; Thermal Resistance, �...�� � �"""._._._."�.._" ""... R-value @ 75 F ASTM C518 ; 7.3 per layer FastWrap 1.5in x 24in x 25ft 1 37.5....... �al XL Roll - °-°°°°°°°- Mold Growth ASTM C1338 w ULE Validated ..�...-..w_......__........................ _.MM.M...._.-_ ---- _1•. _ ...,....,.,in x 48in x 25ft 1 75 -.... .,.— CA Standard 1.5 Low VOCs 01350 ULE Validated Listing and Code Reports Storage w_.._._._...........a__. ......... _.w......_......_......... -..w _........... _. Listed Uses Agency Listing Layers Thermal Ceramics FastWrap XL must be stored in a dry -""--"...ure p ASTM E2 "" �. warehouse environment on pallets. Pallets should not be Grease Duct Enclosure per ASTM E2336 UL G1 ... �� and AC101 (2012,2015 IMC,NFPA 96, 2 stacked. UL ER14229-01 UMC,CMC) " ULC Grease Duct Test Protocol and CAN/ ULC FRO 4,T 2 ULC S144" ..... .... "Through Penetration FireStop System per ��ww._........... See Figure 2 1 pr.2 i ASTM E814, UL 1479 ULC ._._..............�...._w__ w...........................—...ww— -_ HNLJ.V1, 19, 2-hour Ventilation Duct Enclosure UL 1-or2-ho 29 1 per ISO 6944 ULC FRD 3,5,6, 18 I._......— enti.-----wn-D"...... �..._._ m. 3-hour Ventilation Duct Enclosure per _ ^ S0_6944 UL HNLJ.V2 �J-i Electrical Circuit Protective System UL FHIT.5 2m - AIR R � i Whilst the values and application information in this datasheet aye typical,they are given for guidance only.The values sand the information given are subject to normal manufacturing variation and may be;subject to change without notice. Morgan Advanced Materials—Thermal Ceramics makes no guarantees and gives no warranties about the suitability of a product and you should seek advice to confirm the product's suitability for use with Morgan Advanced Materials-'Thermal Ceramics. Publication D. 04 July 2024 • •. • UMorgan , reMasterR "as` ra o �` Advanced Materials Product Data and Installation Gui delines Installation B: Installation on HVAC Duct per ISO 6944 FireMaster FastWrap XL shall be installed by a qualified contractor (Figure 1) in accordance with manufacturer's instructions and laboratory System requires one layer of insulation applied directly to the duct design listings. with 3"(75mm)overlaps at all seams.The insulation is cut to a Materials and equipment length sufficient to wrap around the duct and provide a 3"(75mm) overlap where the blanket ends meet. Adjacent blankets are FireMaster FastWrap XL blanket installed to provide a minimum overlap of 3"(75mm). Banding Aluminum foil tape and/or pinning per Section D is used to permanently secure the Glass filament reinforced tape(optional) insulation to the duct. Carbon steel'or stainless steel banding material, C.i 2&3 Sided Wrap Installation (Figure 3) Minimum 1/2'"(13mm)wide,minimum 0.015"(0.4mm)thick, When space does not allow for a complete wrap applied to the with steel banding clips duct,on all four sides,the FastWrap XL is approved for 2 or 3 sided Hand banding tensioner and crimping tool installations with mechanical attachment to a rated concrete or Minimum 12 gage(3mm)steel insulation pins;steel speed CMU assembly. (See Figure 3 for installation details.) clips,minimum 1-1/2"(38mm)square or 1-1/2'(38mm) C. Mechanical Attachment Methods diameter,or equivalent sized crap--head pins • Capacitor discharge stud gun 1) Banding(Figure 1) . Minimum 112"wide x 0.015"°thick • Approved firestop sealant (13mm x 0.4mm)carbon steel or stainless steel banding is placed around the entire perimeter of the insulated duct General on maximum 10-1/2"°(270mm)centers and 1-1/2"(38mm) from each blanket edge or 1-112°`(38mm)from each collar Cut edges of the blanket shall be taped with aluminum foil tape to edge when using the butt joint and collar method.The prevent exposed edges of the insulation absorbing grease and banding is placed around the blanket and tightened to rnolsture in the event of a compromised grease duct joint or firmly hold the FastWrap XL in place against the duct,but condensation.Overlaps andlor tightly butted joints are used to not cause any cutting or damage to the blanket, block heat transfer in the event of duct deformation resulting from thermal`expansion.Filament tape is suggested to hold the blanket ) Pinning« Pinning on all sides of the duct may be used as in place`until steel'banding or pinning is insta&led to permanently an altemative to banding. For ducts wider than secure the blanket. 24"'(810mm)pinning is required on the bottom of horizontal runs,or on one side of vertical runs(in addition A. Installation on Grease Duct per ASTM to steel banding). When applicable, 12 Gage(0.4mm) E2 3 6 and CAMIUL.0 S1 (Figure 1) steel pins are installed on 12"(305mm)centers along the width of the duct and 10-112"(270mm)centers along the System'requires two layers of insulation applied directly to the duct length of the duct. Fins that extend beyond the outer with tight butt joints at all seams on both layers,The first layer of blanket layer shall be turned down or the excessive length insulation is cut to a length sufficient to wrap around the duct and cut off to prevent sharp edges. Shoot through pins(cup provide is tight butt joint where the blanket ends meet. Adjacent ' head pins)may be used in conjunction with steel banding blankets on the first layer'are butted tightly together with to prevent blanket sa,gw longitudinal seams offset minimum 8"(150mm). The second layer of insulation is installed in the same method as the first layer,with seams between layers offset a minimum of 6"(150mm'), Banding e and/or pinning per,Section D Is used to permanently secure the insulation to the duct r Whilst the values and application information in this datasheet are typicaf,they are given for guidance only.The values and the information given are;subject to,normal manufacturing variation and may be subject tIdthange without notice. Morgan Advanced Materials—Thermal Ceramics makes no guarantees and gives no warranties about the suitability of a product and you should seek advice to confirm the product's suitability4or use with Morgan Advanced Materials-Thermal Ceramics. Publication D. 14 July 2024 • •. • Code: marketing.tc@morganplc.com I I, Mmorgan """ . FireMas er as f"ra� X�L Advanced ed P IAates�ials Product Data and Installation Guidelin'es C E. Access Doors shown in Figure 2.When this method is used,the FastWrap XL must be mechanically attached on either side of the fire rated as. Field Fabricated Access Doors-Each access door assembly ha's sembly using one of the attachment methods described in Section four threaded rods 1/4 inch(6mm)in diameter and 5"027rnm),i� D,spaced a maximum of 1-1/2"(38mm)from the fire rated, length,with one welded to each comer of the door opening. assembly, Hollow steel tubes,4-1/2"(114mm)long are installed outside the access cover plate and over the threaded rods. Four 12 gage G. Support Hanger Systems (3mm)and 4-1/2"(114mm)long steel insulation pins are welded to 1) Grease ducts:Trapeze support hangers shall be spaced on the access cover plate to allow for installation of the three layers of FastWrap XL One layer of FastWrap XL is out to approxlmatelyr; maximum in. mm)centers. Hanger rods straps the same size as the access panel and impaled over the insulation shall be anchored with ith steel drop in or wedge expansion type pins on the panel. A second layer of FastWrap XL is cut so as:tb masonry anchors. No additional protection is hangers required for overlap the first layer a minimum of 1-1/2"(38mm). It is essential) below. and supports meeting the requirements of the Table that the first and second layer fit tightly against the surroundinr4 ��_, wrap with no through openings.The third and outside layer shri91d Hanger Cross Maximum Trapeze Suppork;(or be cut to overlap the second insulation layer by a minimum of Section Perimeter,in(mm) equlval¢nt Yield: clips are installed on the insulation pins tosecure the three layer!$ 148 in(3759mm)w.........2YY�i xm xin x 51 m in 3mne 1-1/2' 38mm . Minimum 1-1/2" 38mm round ors square insula of insulation to the access cover plate. All cut edges of the 3,8 in (10 mm) _.. ..w w (5 m _ _ ) insulation shall be taped with minimum 3"(75mm)wide alumini»arrr threaded rod 144 in(3660mm) 2 in x 2 in x 1/4in angle foil tape.Wing nuts and washers are installed on the four threaded (51 mm 51 mm x 6mm) 2 ........ ............._.....w.,,.....HVAC ducts: ___....._........ w._...... __ww_..............................._.... rods,and tightened against the hollow steel tubes to seal the Trapeze support hangers shall'be spaced on access cover plate to the duct. maximum 60 in.(1500 mm)centers. Hangerw rods or straps I F. Through Penetration Firestop assembly shall be anchored with steel drop in or wedge expansion type ; masonry anchors. No additional protection is required for (Figure 2) hangers and supports meeting the requirements of the Table When the duct penetrates a fire rated assembly an approved f'i i below. stop system must be employed. Figure 2 provides a list of some of Max. Trapeze Support(or the UL/ULC firestop design listings which can be found in the Hanger Cross perimeter, equivalent Yield Certifications Directory at www mulcoPmofo UrSastallcn minaesto (�.......�... u_ gth) www.ulc,ca for Canadian y g y Sincx116 gag 100(2540 �� _.... y m mm Stren e strap system the surfaces of all openings and penetrating items must be ) clean and dry.The FastWrap XL core blanket(or mineral wool q (25mm x^1^^5 ug strap..w age ........_w_._. where allowed by the firestop design listing)must be compresses 'V4in(6mm)threaded 1 12 in x 1-12 in x 3,16in into the annular space.The packing material must be recessed a rod 50(1270) angle(38mm x 38mm x minimum depth from the surface of the concrete or gypsum -- -� assembly. The recessed opening must be filled with a minimum Min(10mm)threaded 1-12 in x 1-12 in x 3/16in 150(3810) thickness of an approved firestop sealant.The packing material I rod angle(38mm x 38mm x type and compression„minimum recess(typically 1/4"(6mm)),, nd V2in(12.7mm threaded. ..........w�2 in x 2 in x 1/4 in angle approved firestop sealant and thickness(typically 1/4"(6mm))shall rod 218(5540) (51 mrr x 51 mm x 6mm) be as specified in an approved UL!ULC firestop design listing -- - When there is not sufficient annular space around the duct to run the FastWrap XL enclosure system continuous through the fire' rated assembly,the enclosure may terminate above and below the floor/ceiling assembly or on either side of a wall assembly as I FIRfe :R Whilst the values and application information in this datasheet are typical,they are given for guidance only.The values and the information given are subject to normal manufacturing variation and may be subject to change without notice. Morgan Advanced Materials-Thermal Ceramics makes no guarantees and gives no warranties about the suitability of a product and you should seek advice to confirm:the product's suitability for use with Morgan Advanced Materials-Thermal Ceramics. Publication D. 04 July 2024 • •. • F• UMorganf@�a:S@1' "aS" � `a� r: Advanced Materials Product Data and Installation Guidelines Maintenance and Repair No maintenance is required when installed in accordance with Thermal Ceramics installation instructions. If damage is limited to the foil,facing, aluminum foil tape can be used to repair:,the foil facing. If an area of blanket is found to be damaged,the following procedure must be incorporated. If the damaged area is larger than 8" (203mm)x 8"(203mm)the entire wrap section must be removed and replaced according to"thermal Ceramics installation instructions. If the damaged area is small(less than 8"(203mm) x " (203mrn)),the damaged area must be cut away and replaced with a neW section V ( 8mm) larger in length and width than the out out, such that the new section can be compressed tightly into the cut-out 4rea.All cut edges of the new section must be taped and sealed with aluminum foil tape. The new section must be held in place with either pinning or banding per Thermal'Ceramics installation instructions. 10.Limitations FireMaster Fastrap XL shall be installed in accordance with these installation instructions and appropriate laboratory design listings. The integrity of FastWrap XL systems is limited to the quality of the installation. 'For personal protective equipment recommendations,please see SDS. Thermal Ceramics, FireMaster, and FastWrap are trademarks of Morgan Advanced Materials. FireMaster products are manufactured by Thermal Ceramics and are distributed by authorised distributors. k P ° i f V Whilst the values and application information in this datasheet are typical,they are given for guidance only.The values and the information given are subject to normal manufacturing variation and may be subject to change without notice.Morgan Advanced Materials—Thermal Ceramics makes no guarantees and gives no warranties about the suitability of a product and you should seek advice to confirm the product's;suitability,,for use with Morgan Advanced Materials-Thermal Ceramics. Publication Date 14 July 2024 • •. • f ' Umorgoan FireMas" er FastWra XL Advanced Materials Product Data and Installation Guidelii :es Figure 1 Grease and HV C Duct Enclosure System v 1 or 2 Hour Shaft Alternative J Zero Clearance to Combustibles 7 i 7 a BWi Joint I tnt TyproW ow N To*wWa wrap Opeon Bull Jam opwn CIemerboard wrap Op•on t.e .LA j .j TAuA v�iqt LEGEND G Two Layers of XL brwlabon Ito, T'M E2 and CANU,,P`S144 Greco Duct Enclosures abytt - .Nt rAxV ant a ., 2r et" dcwm "na 1W �4 rbra � been a " tS dr4 ww t d s e dam �t , rn7 eant swat t o d NtrNttnd aaxz a and n•try n ew Tlw nYpew tl Yt,rr Tlrrd Cr•n1e•�el�Mtr N 1ritlY•r piy w w�e�rw, XLDOI-10 Whilst the values and application information in this datasheet are typical,they are given for guidance only.The values and the information given are subject to normal manufacturing variation and may be;subject to change without notice. Morgan Advanced Materials—Thermal Ceramics makes no guarantees and gives no warranties about the suitability of a product and you should seek advice to confirm the product's suitability for use with Morgan Advanced Materials-Thermal Ceramics. Publication D. 04 July 2024www.morganthermalceramics.com "1• 1"@ 1 ster-O Fasfflrape XL LAMorgan Advanced Materials i Product Data and Installation Guidelines Figure 2 Commercial Kitchen Grease Duct Enclosure System Air Ventilation Duct Enclosure System Through Penetration Firestop Systems s I iw v &mac 3 1 L 1 i 4 . 1 4 r�ulaN�xr"�ter on both si es a ie ns ae�rarw m wr�rrww� ue Wzd wall aisserr64 ... � s�aface Hof the waz8 &q;aswmWy Firestop Designs per ASTM E8141 UL 1479-Consuft UL!ULC Directories for System lie 's UL Lisft F-s a'- t I Flop~ Aenetra t 5 F CAJ-7012 24ar VI FTt 5^1 1! ya. TT l` 71114 3-hmr Coamete/CMU a 4` a5M vow ftmiah W kw,ST t''T G J-M19 : 1 or 24xxx Gm=eftXMU !LIP,FIB ,5 18 terMiMa*at to" T'! r C�4F702 C-A--7UW 24wt CanoeWCAU .16 Ga Duct GIB, t9°^ Tl' Trr 1 of 24,wd Floc aElai 18 Ga Dud 2%EW°'7 wnp ftmah 64"st STI: T� 14wLr F1oQMoo wraptrough to in° 1 2LWs WvrF ; 1 tmrnate at 19 • t L-7t 't 1 or 24wur YIr� &tV 1 7 1 16% 7"&�� i°Refit—*lmr"= I 7145 1 aa'2wN WA 1C�1aat °2S 010 1 &19 tmnhi B at rn°S°rt 0 °RNar �mU 'tlwwunrmiw Crrs anal w+r r YrWd b tll•grll d w wrfrba Whilst the values and application information in this,datasheet are typical,they are given for guidance only.The values and the information given are subject to normal manufacturing variation and may be subject tsa change without notice. Morgan Advanced Materials—Thermal Ceramics makes no guarantees and gives no warranties about the suitability of a product and you should seek advice to confirm the product's suitability;f'or use with Morgan Advanced Materials-Thermal C r mi . Publication D. 04 July 2024 • •. • 'Ir@ aS @r "aSfflr1 UMorgan �� Advanced Materials Product Data and Installation Guldelln;es i Figure 3 Commercial Kitchen Grease Duct Enclosure System Air Ventilation Duct Enclosure System 1 Or 2 Hour Shaft Alternative / Zero Clearance to Combustibles 2 and 3 Sided Wrap Detail f6rAttaching to Walls and/or Ceilings IT �A C 3 Note: Ducts rrKW be independentty supported per code LEGEND 1 i or 2 Hour bated Concrete floor ce n ors"[ 2 Two layers of XL tnsutefion for Grease Duct Enctosuress t' W ut Ctsi one Bad of XL insulation ti oa Dud Endosures tv•w p•r v uu,wrsrt Two layam of XL tnsutat6m kw 3-h AO venttt Lion Duct Enckmae(swo WuLv2) o 3 �� a 4 1 S trick x 2' 50 -3"LZ51 wide bar stock Wrkrated 12'1305 o_c. 5 8 203 maxinurnAir Oak 6 Duct Steal rntn. 117 1 0.015" 0.4 thts k, 4 $ ct' The InleplPj of oa*sn The"Ca km Curt WrAM2 h Hated V Vt Q"tp d Ve M%WftMft Whilst the values and application information in this datasheet are typical,they are given for guidance only.The values and the information given are subject to normal manufacturing variation and may be subject to change without notice.Morgan Advanced Materials—Thermal Ceramics makes no guarantees and gives no warranties about the suitability of a product and you should seek advice to confirm the product's suitability for use with Morgan Advanced Materials-Thermal Ceramics. TOWN OF SOUTHOLD-FIRE MARSHAL Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 htt;�w w solitl'ioldtowll,l.Iy. c 4111 0 FIRE PROTECTION SYSTEMPERMIT Date Received APPLICATION For Office Use Only - PERMIT NO. _ Building Irrctc� mmmm, b Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. "CORK IS'NOW TO BE STARTED prior to the approval of plans and issuance of a permit. Has a building permit been obtained for this project? ❑ Yes [ No If yes,building permit# Date: 3 Jau"10-cp PROJEC,+INORMATION: Project Address: 3 I a Id L4 Ir SCTM# 1000- City: C.O 1 I C1 5 5 Zip• f 458 CONTACT PERSON INF ,�'��ATION: Name: toe- ) 1 ..e.. ' :I' )t .: ;, Mailing Address: f 7 l 4 C h U Q�Ch S+ 4J O I b a-coL 0 -70 Phone#: (D I- 17 -Ll�C(D Email: OCQ LO R49TFt F-. corn Preferred contact method(select one): ❑Phone VEmail ftncAD-ea(Z o 1 t2e, LCk'V'-1 CONTRACTOR INFORMATION: Name: %` 0e-,S i n tFi��00 f-eG-�7 v� Contractor License#: C Mailing Address: j 7 l i..f L' h U2C h ,S'�- 7 e l b yj.eoL 11--7-L1 f Phone#:(P3 J 1 Email: Dave 60 �r--/ -e SCOPE OF WORK: 61 igle2e l) (0 pj�TFIL-e - [O/YI Occupancy Description: ❑Assembly *usiness ❑Education ❑Factory/Industrial ❑ Institutional ❑Mercantile ❑Residential ❑ Storage Description of Work: S+CA fi a callaJe Licheri gg ❑ New System ❑ Existing System Modification �54gten7 Sprinkler/Standpipe/Water Supply Fire Alarm/CO Detection Systems Other Fire Protection Systems (Check all that apply) (Check all that apply) (Check all that apply) ❑NFPA 13,13D or 13R System ❑Manual ❑Automatic ❑ Smoke Control ❑Standpipe ❑ Fire Pump ❑Protected Premises (local) `Wet or Dry Chemical/Clean ❑Supervising station Agent Number of sprinkler heads: ❑Central Station ❑ Kitchen hood/exhaust ❑ Other Floor Area(sq. ft.): n �L 1 � , peo q-11tl ��a � _- TE"CHNICAL MANUAL COMPONENTS DESISIGN INSTALLATION MAINTENANCE One Stanton Street / Marinekt:e,WI 54143-2542,USA / .0.715 7:35-7411 / vvvvw.pyrcrchern.carrt mire Protection Products Copyright 4;2014 Tyco 1='ire Products LP. /All rights reserved. / Bart No,65'1274-06 Chapter 2--Components Page 2-1 REV,5 CHAPTERN COMPONENTS YL �, ... � - y n flan availably; ,l The c YF-iC�-CHCA/1. K1TG1-IE(`� KNIGHT I (I �,yste¢ four different size cylinders:Models PCL 160 (P/N 5.53163), .Q PCL-300 PIN 551194), PCL,460 P/N 551193 , and PC (P/N 551196).Cylinder sizes are expressed to terms of ex`in , guishing agent rapacity (i.e.,the PCL-300 Li es 3.0 gallons (11 A O of ex'trin uishing agent} The oViindoi is manufactured, tested,arm meets DOT requirements.Cylinders come pre•fiiled vwar". � troy �, with extinguishing agent and are charged v0.h dry nitroocn to a pressure of 225 psig @ 70,P(16.5'bar Lr� 21 'C) Cylinder > and valve assemblydimension are shown in Figure 2-1 a. T i ' , � Figure 2-1 b.Wet VaIVe Cross Section. 4k0EiE f 2 P4: WET VALVE REBULMNG " i' t Nees Seal Rebuliding Kit (PJN 550698) _.. � After system discharge,the valve assembly must be rebuilt to ensure proper future operation.The Wet Valve Seal Rebuilding M1. ._`-m ��_ Kit(P/N 550698) should be used. It includes all components _._.A w_-8.. C' _. D,__, f dove Weight necessary to properly rebuild the valve.See Figure 2-2a, Point lb S� cket PC w Model in. 17 L-160 6 0 75 23 ,0 15 44 c 5 34 M13 15 , y MB-... (15) PCL 300 (20.3.)...'(6,�7).. ( 8g)[33,50 (2 4ME 15.o0 2.r 0660 1000 125 06 30 81 /5 15 63 h t 15 (63 7) (783 8) (4-6C0 1000 30.81 41.sF 20 106 h/il 1 (254) (��) (1o5.4) 1) (,8.,�} Figure 2-1 a.Cylinder and Valve Assemblies. All cylinders utilize the same wet valve assembly(P/N 651175),The wet valve assembly is a pressure sealed poppet Figure 2-2a.Wet Valve Seal Rebuilding Kit. type valve designed to provide rapid actuation and discharge of agent.See Figure 2-1b. Item Part No Description item Pare No Desr ipt}n _ -Y��vv •��� p r tem Fart I\iurriber Description — . ... 1 550705 Conical Spring VaEve 0ody 6, 550386 Shrader (alte ._,560705 Conical Spring.. A s 2..., -. u5�0o28.. Neck C7 Rini 1 www._ e Stem O Ring 3 550707 P sroo nu r5C171 1 `)al1 1 Capr Rin , _..�.. 550715 Piskon 0 Rirrg _....... .._._.._. g 10 �55071� Piston 0 Rinq .��, _.�...._...,.� .,... ...�,...w......._�. .....,,„ . ._.., 5 550716 Neck 0-R6n a„ ..,,._ n....�.w...µ�..�.... _... ° 5509E�9 Valve Stern 11 5S038S lal'va Stem _ . 551236 rpssure Gauge _„_ _,_ 6 550714 Valve Cap C Ring .. - ...,...w. ...._...... . ..w,._ ._ 6 550028 Stem 0-Ring 12 551256 Press ire _._-w. � .........._._ _ _ .,..�._ 7 550802 !§d. ._ n qulatnr rotor aptnr 13 1 551261 heal 4 J _ 1 17851 6-32x313,Screw ULFX 3830 December 1,2009 Chapter 2—Components Page 2-2 REV 4 Pressure Regulator Assembly CYUNDER BRAC KETNG (P/N 550985) Vertical bracketing of the PCL-160, PCL.-300 and POL-460 is provided by the Model MB-15 bracket kit(P/j\l 550054), The pressure regulator assembly is avaflable if the complete Vertical bracketing of the PCL-600 is provided by the Model regulator requires replacement(i.e., possible thread damage), MB-1 bracket I<lt(P/N 550053),These kits must be ordered separately with each cylinder/valve assembly.Cylinder instal- Pressure RegWator Rebuflding Kit ation instructions are provided in the installation section of (P/N 551061) this manual. After system discharge, the pressure regulator must be rebuilt to ensure proper future operation.The rebuilding kit(P/N 551061)should be used.It includes all components and instructions necessary to properly rebuild the regulator. See Figure 2-2b, A IN VALVE SEAL,PART BODY NO.55 1261 4B-32 X YS IN SCRE01, PART NO.178,,l 0-AMID, P9SIGN CIr PART 1\10,402745 rPRING,PART 0.PIT ING, 1110 P927 i. _J PI-_ C."N 4 PART - I ,EXTERNAL 0 Figure 2 ND 55 1273RNG 3, d8-32 X 3/0 IN Figure 2-2 b. HOLDINIS 3CI1E1,,11 PART NC�4 1 9C4 5 aoemanc .............. 15.62 in. 3.13 in, (39.9 CM) (ID 2 cn,I) (T9 arn) - .1_3—in. (51.9 C M) 1 0, (5,4 cm) Model VT-1 (P/N 550788) M2_1 _j 20.11t n, The Model VT-J wet valve tool is designed to facilitate the ...... rebuilding of the wet valve assembly,It should be used to held the wet valve piston while unscrewing the cap and stern EXTNGUSHNG AGENT assembly,See Figure 2-2c. The agent used in PYRO-014EM KITCHEN KNIGHT 11 Systems is a potassiurn carbonate based solution that is extromely effective fcr grease related kitchen fires.This agent is available kx cylinder recharging in 1.6 Gallon and 3.0 Gallon containers.For MSDS information, contact PYRO- CHEM at 800-526-1079 or 715-732-346,9 or wwwpyrochern.corn, 1.6 Gallon Shipping Assembly-P/N 553176 3.0 Gallon Shipping Assembly--P/N 651188 Figure 2-2c.Model VT-11 Wet Valve Tool. ULEX 3830 March 1,2006 Chapter 2—Components Page 2-3 REV.3 f The model ECH3 control head is available in both 120 VAC CAUTION (Model ECH3-120, P/N 551202) and 24 VDC (Model ECH3- Precautions must be taken when handling and transfer- 24, P/N 551201). It is equipped with a local manual control ring wet agents as they are caustic in nature.Goggles handle that allows for mechanical system actuation.Operation must be worn at all times.If any agent gets into the of the local manual control requires removing the pull pin and eyes, they should be flushed with clean water for 15 rotating the handle clockwise.The Model EC113 control head minutes and a physician comactecl, If any agent can actuate a maximurn of five (5) cylinders with the 16 gram contacts the skin; ii should be flushed with cold water to 002 cartridge.See Figure 2-5. prevent irritation.The agent Is electrically conductive. Note! When utilizing electric detection, it Is recommended Care must be taken to thoroughly clean up any agent that Lhe Model ECH3-24 electric control head be used with discharged around electrical appliances before turning either the AUTOPULSE 542R Control Panel (Fart No. the power on. 433607) or the AUTOPULSE Z-10 Control Panel (Part No. .mm.- ZI-30525), If the ECH3-120 control head is to be utilized„it After system discharge, agent must be cleaned up immoadl- must be used with Solenoid Monitor, Modell 'aM-120 (Part No. ately with hot, soapy water to prevent corrosion of effected 550303), along with a UL Listed 1 A, 120VAC power supply surfaces, (by others), In accordance with NFPA 17A, NFPA 96, and the o local authority having jurisdiction. . HEAD The Model MCH3 mechanical control)read is a fully mechani cal control head which can be connected to the PCL- L'. ro,sPhee ME 1 6 013 0 0/4 6 0/6 0 0 cylinder valve.This control head will support a fusible link detection system, a remote mechanical pull rV,. cfl—s ( ors srr.urex str,�, \_u 1.1P[f[i IFS YI SfldltS 1?. station (Model RPS-M), and a mechanical or electric gas shut- } ,....... ...,....... ...,...,. y ..,,,. off valve.A micro electric switch (Model M S-SPD�; MS-DPDT; ..w MS-3PDT, or MS-4PDT)can be ordered separately and field Figure 2-S. f,... _... installed.it is equipped with a local man!ra€control handle brat allows for mechanical system actuation.Operation of the I;ocal Electric Control Head. Y� p„ � oc478!src manual control requires removing the pull pin and rotating the handle clockwise,The Model MCH3 control head can actuate MODEL NMCH3 m MECHANICAL a maximum of five(5)cylinders with the Ira gram CO,, CONTROL �� � ���� �� � � �� cartridge,See Figure 2-4, .. .......-•._........__.-.._-..,......--...._..-....--.-.........___,..,_-....... The Model NMCH3 Mechanical Control Head is a fully MODEL MCH3 CONTROL HEAD mechanical control head which can be connected to the o- PCL-160/300/450/600 cylinder valve.This control head will u uvwrarrnrw.n SUPPOrt a fusible Ink detection system, a remote mechanical pull station (Model RPS-M), and a mechanical or electric gas shut-Off valve,An electrical (snap-action) switch (Model MS- I " oT arA � uL SPIN, MS-DPDT, MS-3PDT, or MS-4PIDT) can be ordered separately and field installed.There is no local manual actu- °...__. w_ ) _....0 ation for the Model NMCH.The Model NIMCH3 control head can actuate a maximum of five (5) cylinders with the 16 Figure 2-4. Mechanical Control Head. gram CO2 cartridge. ,,,, �MOD ram 1, MODEL NMCH3 CON�.. � CTRI 0 COL HEAD i CONTROL HEAD .. I The(Model ECH3 electric control head is an electrically oper- ated control head which can be connected to the PCL- o-160/300/460/600 cylinder valve.This control head vrill support Tr r i an electric thermal detection system, a remote mechanical �t,ti V pull station (Model RPS-NI), and an electric gas shut-off valve j Figure. . ...�. ... .. ...... . ........_........_ .---.�-it will not support a fusible link detection system.An electric (snap-action)switch (Model MS-Di DT) is included. Fi g Mechanical Control Head. an'uze�r^c ULEX 3830 December 1,2009 Chapter 2—Components Page 2-4 REV.4 MODEL EN-MCU3 ENCLOSURE MODEL VIB-P2 - CONTROL HEAD (P/N 551208) MOUNTING BRACKET (P/N 550853) The Model EN-MCU3 Enclosure is used for vertical mount- The Model IVIB-P2 InOUntIng bracket rrust be used to Mount ing of a single PCL-160, PCL-300 or PCL-460.The EN also includes a mechanical control unit, eiii-ninating the Model MCH3, NNICH3, or ECH3 Control heads if the the need for a Model MCH3 Control Head.See Figure 2-6. control head is not mounted directly on R cylinder valve.See The PCL-600 cannot be mounted in an EN-MCU3. Figure 2-7. 00 28.125 IN. (71.4 cm) 11kt 0 0 13125 lN IN, (313 care) m 127.0 rrl (FRONT) tSIE)E) Figure 2-7. Model MB-P2 - Control Head Figure 2-6. Model EN-MCL13 Enclosure, Mounting Bracket, 00104SPO 02XBPC MODEL EN-S ENCLOSURE PNEUMATIC ACTUATING (P/N 550966) CYLINDERS The Model EN-S Enclosure is used for vertical mounting of a single PCIL-160, PCL-300 or PCL-460 when it is used as a Model PAC-10 (PIN 550104) secondary agent cylinder in a system.Dimensions are the The Model PAC-10 is a pneurnatic,actuating cylinder that can same as the Model EN-MCU3 enclosure (see Figure 2-6).The aCtUate,a n-iaximum of ten (10) agent cylinders simultane- EN-S has no control mechanism, and must be used in ously,The Model PAC-10 includes a DOT 4BA350 cylinder conjunction with a Model EN-MCU3 Enclosure or a Model pressurized with dry nitrogen to 350 prig (ci? 70'F(24.1 bar MCH31ECH3 Control Head The PCL-600 cannot be mounted P 2-1 'C), a brass valve with pressure gauge, and a wail in an EN-S. mounting bracket,A Model MCH3, WACH3, or ECH3 control hoad must be purchased separately and connected to the 116 GRAM CO2 CARTRIDGE FIAC-10 to open the valve.See Figure 2-8. (P/1\1 551059) CONTROL HEAD (SOLD SEPARATELY) The 16 Gram CO2 Cartridge is required to pneumatically actu- F� V4 IN. ate the tank valve,The cartridge is installed in the control DISCHARGE PORT head on top of the tank valves.The cartridge shipping assern- 01 bly contains 6 cartridges. 14,50 in. (HS cm) 12 2.5 in, pp 131 1 4,00 in.(10.2 cm) Figure 2-8, Model PAC-10 Pneumatic Actuating Cylinder, W28,!7PC !ILEX 3830 December 1,2009 Chapter o Components — Page 2-5 REV 3 DETECTION EQUIPMENT ModeUFLH~1 (P/N 550876) The Model FLH 1 fusible link hanger is an accessory Model FLK-1 ���� ������\ ` ^ designed tosimplify 'he installation of fusible links inthe fusible link line.\t can be used with the Model FLK-1fusible The Model FLK-| fusible link kit Includes a1O|n(u5 4»m) link kit (kits must be ordered eeporately).The Fusible Link steel bracket,two 1/2 in.EMT connectors, bwo (2)oeb|m Hanger makes itpoe*|b\ato install fusible links without cutting crimps,and two(q^8"hooks. Fusible links must beordered and crimping loops�n the fusible link line for each link,They separately.Gee Figure 2-Sm. are available in packages of2s (FLH-25)only.See B8mme2- gu. Model FLK-1A (PIN 550132) The Model FLK'1A fusible link kit includes an a in.(on.aun`) steel bracket,two(2) 12 in.EMT oonnoctors.two (z) cable crimps, and two (x)^S^hooks,Fusible links musi.beordered owpunate|y. TERM AL LINK 1/2wsNrr Figure o-ea, Model FLK'1 Fusible Link. FUSIBLE LINK BRACKET KIT (SOLD SEPARATELY) (SOLD SEPAPATELY) FLANGER F|ou,e2-gu. Model FLH-/ Fusible Link Hanger, ULEXuxuo ~ March 1. 2ooe Chapter 2-Components Page 2-6 REV 5 Fusible Links Therma� DeteLtors The fusible Hnk is des�gned to separate at a specific tempera- Rate-cornpeusjt�ng therrna�dOWCA(Jrs air, etof rNllly Open, ture, releasing tension from the ftjs8ble fink flne, causing rri echanicat co�jlt,,,jct e , swRrhes designed to operate at a sy Rtem,. actuation.See Figure 2-10, factory preset teMPeratUreJ'hK"y are alvaW6 in four preset Note:When POssRfle, ternperatt,ae readings should be taken t.evnperahjreI3 wig(;h r7eet NFPA standards and are Cf.. Listecl at each detector focatlon to determine optirnurn fusible firik and FM Approved, After determining the maximum ambient temperature ralkngs.Tprnperatw,e can be recc)rded using ten-porature at th© thefrnal detector location, select the etther a aiaxlmunn relgisterhig therrnometer, Part No, 152,10, correct thermal detector according temperature tN'�e(by others), ear any other accurate Cheer- tion chart below: to the ternlporaturC Gondi- mornater that will record thew maxirnum temperature experi- Thermal Pneed at the detector location. Detector Maxirnurn ftbient 0 Mode� No. "rempera hve Part Number FD-225 155- F (68-C.) 13976 TD-325 255° F.(124°C.) 139705 TD-450 380- 1--. (193°C.) 13974 TD-600 5301 17% (277°C.) 13971 Nolma A, treftsisM rush of warm aRr up to 40 IF(4 *C) per M rlute may expand die sh0,bL1''not enough to trigger the Figure 2-10. ML Style Fusible Link, Unit,Temperature increases savor40 IF(4 1C) per aiinute DOZOSIPC > howaver, may imliiate an alaroe�cu:mdlflon After eterr ining ft maximurli amNent temperature at the "' r1N' LEADS fusib e Unk location,&eiect the corrcaLt fusVe link according to (151 MIV,) the temperature condition char!Wvvv. MaM To Be Used 129 5 mrn) Fusible Link I N."T] T (, Where Temperature HEX 3.7 IN. Model No. Does Not Exceed Part Number �'q�'3 MM) FL-11 65 100- F (38- C.) 55036B FL-212 FL-280 150-F. 66° C.) 550365 225°F.(107°C.) 550366 FL-360 290°F (143°C.) 550009 Figure 2-11,Tfiernnaf Detector. FL-450 360°F (182°C.) 550367 FL-600 400° F.(204°C.) 56816 °-HexilWe Conduit Flexible Conduit can be used with the Mechanicai Pull Station Assernly(Part No. 551074) and Mechanical Gas Valves. Flexible Condult eflmfr,rates C,lja need fcr rigid EMT conduit in the mechanlcaI pulp slauk)rj and gas vaivp lines,significantly reductno the cweralh i,asfiihatlon done' Part No. D cr8rqkxn 434525 FlexNe Condult-500 ft(152 m) 435959 Flexible Condu4--500 ft(152 m) and Wlre ROPe--5)00 ft(152 m) 435979 Flexible Conduit Strain Relief(50-Pack) 434347 Flexible Conduit Insert(50-Pack) 436063 Condult Offset (6-Pack) 436150 P-Clip (50-Flack) 79827 Compression Union, 112 in. >55813 1/2 in.Cornpression Connector ULEX 3830 December 1, 2009 Chapter 2 —Components Page 2-7 REV 5 - L PS-IVI r EMOTE � . �� __„gyp ADAP7aR3aUY' �c. C ICAL PULL STATION p', - .GA3KEr ��""� 51074) d»...... xE".. .E.00Mhr.4SHEF Remote manual control for the Model EUICE-i3, NMCH3, ar -m ``NUT ECH3 control head is provided by the Model RPS-M remote mechanical pull station. It is connected to the systern control Figure 2-13. bulk-Seal Adaptor. P head by stainless steel cable.This cable is enclosed in 1;2 in. EMIT conduit with corner pulleys or flexible conduit with bends "COMP S S 9' and/or corner pulleys at each change in direction.The remoteF �� � � ADAPTOR mechanical pull station shall be located at[he point of egress. This adaptor is a mechanical bulkhead fitting that produces a See Figure 2-12. liquid-tight seal around pipe and conduit when installing distri- _..._..M..... ._. ._.__..µ. ..... bution piping and detection conduit through restaurant hoods (fJ T and ducts.The"Compression-Seal"Adaptor is a straight- IM CASE O` through design requiring no cutting or threading of conduit or pipe.The adaptor is available for EMT conduit size of 1/2 in. (Part' No.79152), See Figure 2-13,"Cornpress!on-Seal" Adaptor Shipping Assembly must be ordered as stated below: Shipping _. .mm..-_...a.. ,.._ ...C ...I Assembly Hole Size Size 4 2 Part No. City. Required 1/2.in.EMT Conduit 7 ..... s"rANr�AHoa iN.xxlN ELFc. g15t3 24 1 118 in. JUNUT[ON BOX =Z RlDG Er}BRUSHED "'""`ALUMIRuM r-Acs PLATS ADAr Ton sor)y Cli"i KE T LQCffWAFiHER r qq BREAK ROD RED PLAS PC r D'RING Figure 2-13a. Compression-Seal Adaptor, 1/4 IN.RADIUS `"�-� 00D SEAL." ADAPTOR ASSEMBLY ON ALLCORNCRS Figure 2-12.Model RPS-M Mechanical Pull Station. This adaptor is a mechanical bulkhead fitting that produces a V.029,5,2P C liquid-tight sea!around 1/2 in.EMT conduit when installing the detection line through restaurant hoods and duct,The adaptor "QUIK-SEAUADAPTOR accepts a high temperature pulley elbow and,when used, GOC'rP,Ct!y pOSitIUr1S the elbow or CC)CldlJlf in title with the conduit The`Qu!k-Seal"adaptor is a listed mechanical bulkhead fitting adaptor hole in the detector bracket.The"Hood Seal"eliminates the need for multiple elbows when penetrating the top of a hood that produces a liquid-tight seal around bath distribution piping when installing the:detection litre."Bend Seal"Adaptors are and detection conduit which runs through restaurant hoods and c S ryr �r ducts.The"Quik-Seal'adaptor accepts threaded pipe or available in quantities of 6 as Shipping Assembly P/N 4�32,E 3. conduit.The adaptor is available for 318 in.and 1/2 in,pipe or conduit sizes.When using with EMT conduit, a conduit connec- se"L nu for must be installed in each end of the adaptor.The"Qu!k- ssaL Seal"Adaptor Shipping Assembly can be ordered in single or ADAPTOR,.. package of 24. r KE.Y Assembly Y l i_so�t sy u Shipping PUL LEY h Y Hole Size r. Size Part Na. Q.t . R� aired t �- OF 3/8 in, 550857 1 1 1/8 in. USE ONLY FLEECY ELBOW,PAR NO.423250 1/2 in. 560859 1 1 1/8 in. U Figure 2-13b. Hood Seal Adaptor Assembly. 3/8 in. 550858 24 1 118 in. 1/2 in. 550860 24 1 1/8 in. ULEX 3830 December 1, 2009 ~ Chapter 2—Components �Pagoo'o REVa GAS SHUT-OFF VALVES EGVSO Electric Gas Shut-offl/a8ve rNote: Gas valves are approved for indoor ummonly. A gas shut-off valve ia required on all systems used topmtuo� � a yaufuo|od cooking appliance to stop gas flow|nthe event of system uotuaUon � ULL�o�ed electric | b ���� ����������� u��� ����t~�1������ � ee rcgaovovecan e uuedw�Lho|�h*r�ha Model MCH3orECH3 control head.The Agem shut-off valve is required on all systems used to protect valves are rated for natur*( and LP gas.Valves are available in a gas fueled cooking appliance/oe�op gas flow In the event °12O VAC (see Figure 2-14o). Electric gas valves are available oYsymtmm actuation. A mechanical gas valve can hm used with in the following sizes: the Model MCH3 control head, It is connected to the ayotam Maximum control head by stainless steel cable.This cable|ueno|oaed |n Valve OporaUng Part.1/2 |n.EMToonduit with a corner pulley at each change in Model No, Size prexou,o Number d|re�|on.The valves are r� fo r ----- ---- ----- ------ ~Figure 2~14).M*cUan|um|gas valves are available in the EGVS0'75 3/4/n 50 psi (3.5 be/) 13707 fo|/mwingoizeu� EGVS0`700 1 in. 26poi (17ba) 13/08 EGTVS0 '/25 1'1A1n. oopa> (1Jbar) 550360 P.Note:Maximum operating pressure for all sizes ufAV E(WSO-'5Q 1-1/2 in. 25pai (i,rbur) 13/0e Mechanical Gas Valve |n5 psi (0.4bar). 5GVS{-200 2 (n. 25pei (I./bar) 13710 E� Valve Part i VSO'250 2-1/2in s p*i (0.3bar) osoono Model No. Size Dirn,"A" Number �B3VSO-300 3 |n. muu| (0.3bar) 17643 OV-75 81$in. n/e in,(1,Ocm) saOoRo 8V_100 | in. 3/8 in.(1num) 550594 ~ Gv'125 1'1Ain. 1513z in,(|.ucm) 550595 GY-150 1'//2in, 15/32 in.(/.2cm) 550596 GV-20 2hs 15/32in (I�2 cm) 5G1040 G\-250 21/2io. 29/32in-(2Jcm) 550185 �GV-300 3in. 2902 in.(c,3cm) 550186 1A ~ Figure o-14a. Electric Gas Shut-off Valve. mmtu:A UL L/oted manual reset relay is required when using an electric gas va|vo,The PYRO-CHEN/I KITCHEN KNIGHT U DIM."A Model 3M-12Ooo|eno/d monitor must bm used for this ee 2 2J purpose ox*x, � Figure u-1^.GY-Ser|ma Mechanical Gas Valve, 0LEX 3830 December 1. ouoe Chapter 2—Components Page 2-9 REV.3 ~ CORNER PULLEYS TEE PULLEY (PyM 427929) The Tee Pulley is used mchangm the direction nf two wire Model SBP-1 (PIN 415670) ropes bySo~. |(must be used io areas where the temperatures am*��|ntherangeof32"F� 13O°F(O"�to54~�)� Pu||ey Aonmerp�|ey|s used whan�mru change|n��n|eaaele� �aacan ha uood in mechanical gas valve a�umUonUneuand oeh/nd|mcdnninregu|red�The�nd�|�BP-1 oomerpu||�y|o �mo�manua� puUo�Uon |inooPuUoy�eoscann�beuued equipped w�ho set screw Mthn8�roonn��on� `/2 in.E�T � within 8eeF�una2-17 conduit. 8e� Figure 2-�S. � � ' CAUTION The Tee PL!lk-ly must never be used to connect,rnulti- pie fusible- ink ines lo a single control head, �.kPI ° Figmre2-15. Modm|sePA CormerPuxey. ~mM) Model CBP~1 (PIN 423250) A corner pulley im used wh*nowara change |n stainless uab|o | Figo/ex'�r�mwdelTp-1 Tee Pulley. d|r*�|onio required.The Model C8P-/ ioag/eayo-hgh� � °"'� corner pulley designed for areas likely to experience exces- sive depook huiW-up. |tia equipped with a compression fitting WRE PROPE ~for connection tn1/z in.EMT conduit.See Figure o-16o. The //1G in,diametera�ain|eoo steel wire rope muntbeused Note.The Model CBP'1iu not e liquid tight seal fur peneos~ with actuators, Jnterbzs and gas valve components mquiring '— Uonofhoods and/or ducts, awim rope connection.The stain|eao steel wire rope is supplied in 50h(152 m) |ong(bowdh P/N 15821, and 500H (162 m) lengths with P/N,s000.Peter,mme Components UaL for partnumbers on nrimpa, stop sleeves, endG-hookm. � Figure 2-10a, Model CBP'1 Come, Pulley. =mm Model WBP-1 (P/N 5509132) A corner pulley|a used whenever m change inetnin/esscable direction in required.The Model VVBP-,l |aaweather-proof corner pulley designed for areas likely tobe exposed tomoin- tura. It is equipped with female pipe threads lornonnocUonto °1/2 in.hg|U conduit.Gee Figure248b. Figure 2-16b, Muda|VVBP-1 Corner Pulley, uLEXoo3o December 1` 2OO8 Chapter 2—Components Page 2-10 REV.6 FLECTRICAL SWITCHES See NFPA 72,"National Fire Alarm Code,"initiating Devices The electrical switches are Intended for use With electric gas section, for the correct rnothod of wiring connection to the fire valves, alarms, contactors,lights,contractor supplied electric alarm panel. power shut-off devices and other electrical devices that are designed to shut-off or turn on when the system IS actuated. MODEL SM-120 SOLENOID RAMTOR NOTE The Model SM-1 20 solenoid monitor is (P/N 550302) used in No electrical connections shall be made inside the >conjunction with the Moclial ECH3-120 control head 10 super- control head,All electrical wiring shall exit the control vise the actuation and detection circuits. in the eveqj of a head through the knock-out on the side of the box.All -problern in the circuit,a light on the rnonhor goes out.Two electrical connections must be made in an approved sets of NO/NC dry contacts are provided.The unit mounts electrical box, ,directly to a three gang wall outlet box,The Model SM-120 acts as a reset relay when used with an electric gas valve. Switches are available in kits:One Switch Kit, Part No. Electric pas valve wiring instrudions are provided In the instak 5511054;Two Switch Kit, Part No.551155;Three Switch Kit, lation section of this manual,See Figure 2-18. Part No. 551156, and Four Switch Kit, Part No.551157. Mounting hardware and 12 in.wire assemblies are provided Note:When utilizing electric detection, it is recommended that with each kit.Each switch has a set of single-pole, double- the Model ECH3-24 electric control head be used with either throw contacts rated: the AUTOPULSE 5421-1 Control Panel (P/N 433607)or the UUcUL/CSA Rating ENEC Rating AUTOPULSE 7_-1 0 Control Panel (P/N 430525). If the EC 1­13- 250 VAC, 21 A Resistive IE4T105ji Approved 120 control head is to be utilized, it must be used With 250 VAC, 2 HP 250V, 21A Resistive Solenoid Monitor, Model SM-1 20 (P/N 550303), along with a 125 VAC, I HP 8A Motor Load UL Listed I A, 120VAC secondary power supply(by others),in COMMONccordance NiRl NFPA I 7A, NFIDA 96,and (lie luczd authority having jUdi(.Vori.When the Scftieid Nlomtar,Model SM-120 (RED) N.O.NO. ris Ae (8 LACK) (P/N 550303), is used as a i eset relay with an electric gas valve, a UL Listed 1A, 120VAC secondary power supply is not 0 required. (BROINJN) I r"N se, Figure 2-17a. Model MS-SPDT Snap-Action Switch. =7_=Z=== The Alarm Initiating Switch Kit, P/N 550077,can be field q`µ mounted within the control head.This switch must be used to close a supervised circuit to the building main fire alarm panel when the control head actuates,This action will signal the fire alarm panel that there was a system actuation in the kitchen area,The switch kit contains all necessary mounting compo- 0 0' nents afon5)with a mounting instruction sheet.The switch is rated 50 mA, 28 VDC. TOWARD RPAR OF SPACER WHEN SPACER AND CONTROL HEADv,,,,,,,, SWITCH ARE PROPERLY 0 MOUN FED,THIS DIVIDER MUST BE BETWEEN TJ IE N.0�AND N.C.-rERMINALS Figure 2-18, Model SM-12D Solenoid Monitor. cows N C, ME AND RTTINGS Pipe and fittings must be furnished by the installer.Schedule 40 stainless steel,chrome plated, or black pipe and fittings must be used.Galvanized pipe and fittings are riot to be used. Figure 2-17b.Alarm Initiating Switch. ULEX 3830 December 1,2009 Chapter 2 Components — m Pag*21i REV ~_ ENT DISTRMUMN HOSE AND RESTRAINING CABLE KIT ERINJG The Agent Distribution Hose and Restraining Cable Kit, Part No.435882,consists o/a58(1�5n`) long AQ*nLDiskibuVon ��an�wnm Hose, e8ft(O�Sm) long Restraining Cable, and aRestraining Cable Hardware Distribution ~-a»� utilized with contamdappliances found |ncommerc|W kitchens «w*m * The hose a||owm for movement of thmmpp|iance for n(eaning ��-u^p m without having to disconnect any fire suppression system discharge piping. STAW0ESS STEEL | } ACTUATION HOSE Figure 2-20. Nozzles. The Stainless Steel Actuation Hose is used*oconnect thsaum- °="= atiun line compression tees and can also bmconnected end is end.The hose has the mamethread'7/16-20.as ffim Uuin8a� RUBBER BLOW-OFF CAPS See Figure o-1y. Tha Rubber Blow-Off Cap helps keep the orifice o/the nozzle {eeofgmuaooro�er substances �ntcould i�mhevywi� t���P�t��' Lengthagent distribution,A retaining strap ahachoo the b|ow+off cap m 417582 8 in.(2ocm) -he nozzle, Rubber Blow-Off Caps must boordered as 31800 1G in.(41cm) Shipping Assembly Part No.55oo-18,which contains 1ob|ow' 32336 24 in.(0/ cm) onoapo� 430815 42 in.(1Orcm) Fitting Part No. Description ���on� ~ 31810- Male Elbow pY16'20x1/4 in,Np7l 31811 Male 7ba(7/18-2Ox7n6-2Ox 'U*|n0PT) 32338 Male Straight Connamor(7,11s-oox1/4 in. NpT) ~ Figure 2-21. n1 mu no 20 MVEL A113APTOR (P/N 418569) Figure z-18.Stainless Steel Actuation Hoee, The Swivel adaptor consists ofa swivel nut, swivel body,and "=^= uwive/ hall,All are ohrome-p|ated.The swivel adaptor allows the nozz/atoba rotated approximately 3o°|n all directions, NOZZLES Swivel Adaptors can be ordered aoa single Swivel Adaptor or Nozzles have been developed for appliance, p|enum' and duc/ Swivel Adaptor Shipping Assembly, Part No.4un5ro,which applications,All nozzles have a specific flow po|ntva(uaand ~contains e6 swivel adaptors.See, Figure o-QL are supplied wth metal blow-off caps mpreven/clogging, Each nozzle|n stamped with the model numU*r,See Figure 2'20. Application limitations are provided in,he design section o/this manual. um-,owpr Part No. Description FlowMo FEMALE THREAD 551029 1H Nozzles, pack o//en (1o) 1 551020 1L Nozzles, pack of ten (1C) 1 551028 2H Nozzles, pack o[ten (10) 2 551027 2LNozz|es, pack nften (10) 2 mr � um �uwpr 551038 uDNooz|ea. pack of ten (1O) 2 non�mw^ �r ~°--- m^Ls/xFIsxo Figure u-ou.Swivel Adaptor, °mm, uLEXooau December 1'zoon Chapter 2—Components Page 2-12 REV 3 NOZZLE AIMING DEVICE The Nozzle Aiming Device, Part No,551265, is )equired to properly aim each nozzle to the correct aiming point.The device clamps to the nozzle and emits a small laser light that reflects on the surface that it is aiming at,The nozzle can then be rotated to point at a predetermined aiming point and than tightened to hold that angle,The aiming device requires an adaptor, Part No.550926,to attach it to the nozzle.The adaptor must be ordered separately.See Figure 2-23. ADAPTOR(ORDER ck� 9" SEPARATELY) NOZZLE x1 AIMING D5%Ar,E Figure 2-23. Nozzle Aiming Device. MY20 ULEX 3830 December 1, 2009 Chapter 2-- COMponents Page 2-13 UST MODEL NO. DESCRIPTION PART NO. MODEL NO. DESCRIPTION PART NO, PCL-160 i.6 GALLON CYLINDER ASSEMBLY 553163 � EGVS0-75 ELECTRIC GAS SHUT-OFF VALVE 13707 PCL-300 3 0 GALLON CYLINDER ASSEMBLY 551194 3/4 IN. PCL-460 4.6 GALLON CYLINDER ASSEMBLY 551193 -FGVSO-100 ELECTRIC GAS SHUTOFFVALVE' IN, 13708 PCL-600 &0 GALLON CYLINDER ASSEMBLY 551 f96 FGVSO-125 ELECTRIC GAS SHUT-OFF 550360 PAC-10 PNEUMATIC ACTUATING CYLINDER 550104 `VALVE 1-1/4 'N. PCL-300 CANADIAN-3.0 CAI LON 551195 EGVSO 150 'ELECTRIC GAS SHLET-OFF 13709 CYLINDER ASSEMBLY VALVE 1 112!N. PCL-460 CANADIAN 4.6GALLON 551192 EGVSO-200 ELECTRIC GAS SI­­IU­T­OFFVAI_YE 2 IN, 13710 CYLINDER ASSEMBLY EGVS0-260 ELECTRIC GAS SHUTOFF 550263 PCL-600 CANADIAN-6.0 GALLON 551197 VALVE 2-1/2 IN. CYLINDER ASSEMBLY > EGVSO-300 ELECTRIC GAS,SFIUT-0EFVALVE 3 11\L 17643 PAC-10 CANADIAN --PNEUMATIC 551125 GV-75 MECHANICAL GAS SHUT-OFF 550593 ACTUATING CYLINDER VALVE 3/4 IN. MB-1 MOUNI ING BRACKET(FOR PCL-600) 550053 GV-100 MECHANICAL GAS SHUTOFF 550594 MB-15 MOUNTING BRACKET 550054 VALVE I IN, (FOR PCL-160/300/460) GV-125 MECHANICAL GAS SHUTOFF 550595 MB-P2 MOUNTING BRACKET 550863 VALVE 1-1/4 IN, (FOR MCI-13 ECH3-24/120) GV-150 MECHANICAL GAS 31 1UT-OFF 550596 MCF13 MECHANICAL CON FROL HEAD 951200 VALVE 1-1/2 IN. NMC113 MECHANICAL CONTROL HEAD 551203 GV-200 MECHANICAL GAS SHUTOFF 551049 (NO HANDLE) VALVE 2 IN EN-INICU3 ENCLOSURE(FOR PRIMARY 551208 OV-260 MECHANICAL GAS SHUT-OFF 550185 CYLINDER) VALVE 2-1/2 IN. EN-S ENCLOSURE(FUR SECONDARY 550,1366 GV-300 VIECHANICAL.GAS SHUTOFF VALVE 550166 CYLINDER) 3 IN. ECH3-24 24VDC ELECTRICAL.CONTROL HEAD 551201 >MS-SPDT EL.ECFRICAl_SWITCH-SINGLE POLE 551154 ECH3-120 120VAC ELECTRICAL.CONTROL HEAD 551202 DOUBLE THROW MS-DPDT ELECTRICAL SWITCH DOUBLE POLE 551155 8 IN.S.G.ACTUATION HOSF 417582 DOUBLE THROW 16 IN.SS.AC FUA`l ION HOSE 3 1 E309 MS-3PDT ELECTRICAL SWITCH 3 POLE 551156 24 IN.S.S.ACTUATION HOSE 32336 DOUBLE THROW 42 IN.S.S.ACTUATION HOSE 4306"15 [AS-41PIDT ELECTRICAL SWITCH 4 POLE 551157 MALE ELBOW 31810 DOUBLE THROW MALE TEE 31 B"I I ALARM INITIATING SWITCH 550077 MALE STRAIGHT CONNECTOR 32333 CO2-6 5 x CO2 CARTRIDGE(i 6 GNI) 551059 1 H WEE NOZZLE(PACK OF 10) 551023 O-RING,ACTUATOR ASSEMBLY 55531 1 L WET NOZZLE(PACK OF 10) 551028 CBP_l COMPRESSION BEARING 423250 2H WET NOZZLE(PACK OF 10) 551028 CORNER PULLEY 2L WET NOZZLE(PACK OF 10) 551027 SBP_ 1 SCREW BEARING CORNER PULLEY 416670 2D WET NOZZLE(PACK OF 10) 551038 WBP-1 WEATHER PROOF BEARING 550982 SWIVEL ADAPTOR(RACK OF 25) 423572 CORNIER PULLEY RUBBER BLOrN-OFF CAPS(PACK OF 12) 5150016 TP-1 TEE PULLEY 550166 RPS-M REMOTE MECHANICAL-PULL SFATION 551074 VJET VALVE CAP 550831 FLK-1 10 IN.FUSIBLE LINK BRACKET KIT 550131 CO,,JICAL SPRING(WETVALVE) 550705 FLK-1 A 8 IN.FUSIBLE LINK B[---IACKE-r KIT 5,90132 PRESSURE GAUGE(WET VALVE) 551236 FLH-25 25 x FUSIBLE LINK HANGER 550B76 PRESSURE REGULATOR ASSEMBLY 550985 FL-165 FUSIBLE LINK 165'F 550368 WE'r VALVE REBUILDING KIT 550698 FL-212 FUSIBLE LINK 212'F 550365 PRESSURE REGUILAFOR REBUILD KIT 551061 FL-2120 FUSIBLE LINK 2C30°F 550366 VT_I VALVE TOOL(WET'VALVE) 550788 FL-360 FUSIBLE LINK 360'F 5150009 NECK O-RING(WET VALVE) 550716 FL-450 FUSIBLE LINK 450'F 550367 PISTON(WET VALVE) 550707 FL-500 FUSIBLE LINK 500'F Kai 6 PISTON O-RING(WET VALVE) 550715 SM-120 120VAC SOLENOID IMONITOR 550302 VALVE CAP O-RING (WET VALVE) 550714 TD-225 THERMAL DETECTOR 225'F 13976 RI_:-160 -1 6 GALLON RECHARGE 553176 TD-325 THERMAL DETECTOR 325°F 139715 RL-300 3.0 GALLON RECHARGE 551186 TD-450 THERMAL DETECTOR 450'F 13974 PCL300 F TEST TANK 551024 TD-600 THERMAL DE-TEOFOR 600'F 13971 PCIL-460T E ES E-FA,N K 650902 PCL-600T TEST LANK 550901 RUBBER BLOW-OFF CAP 550015 ULEX 3830 December 1, P009 , ~ Chapter 2-Components Page 2-14 ("'ONWONENTS R.AST (Coo)nfinued) MODEL NO. DESCRIPTION pxRrmu _ - - - �ou WET NOZZLE CAP 55/523 - - - 1ox WET mozzLeSTRAINER 551529 - - - 1nx WET NOZZLE D-R|m8 ss|ouo - - - VALVE STEM o-x|wa souono - ' - COMPLETE WET VALVE ASSEMBLY 55/175 poL-AK ne:xAnGEAu«pTo9K/T 55/240 - - - MEAGUR|0G8TICK 551039 - - - STAINLESS STEEL WIRE ROPE,nOp7 1682/ - - - STAINLESS oTcELWIRE ROPE,nnoFr 79653 WC-100 OVaLSI EeVEoR|MpG 550122 (/oo PER PACKAGE) - - - STOP SLEEVES(PACK nr/o) 2,49/e ~ - - - FLUSHING OVNCENrRxrc(o2Vz) ssoseu - - - FLEXIBLE CONDUIT-5uoFT(|som) 43*525 - - - FLEXIBLE CONDUIT-soopT(1m2 rn) 435959 AND WIRE ROPE-sonFT(/sum) - - - FLEX|BLE CONDUIT STRAIN neusr msu/u <soR4OK> - - - FLEXIBLE CONDUIT INSERT(snPACK) 43*347 - - - oomou|Toppaer(6-R^oK) 43e0e3 - - - p'cup(s*Fwou) 43e150 - - - COMPRESSION UNION,i/2IN. 79827 - - ~ COMPRESSION CONNECTOR, 12|N. 55e13 - - - xEmmY PENNY mOzzLEKIT ssouau c02-6 nxcouo^nrR|ooe 5510n9 - - - COMPRESSION'SEAL ADAPTOR 79153 AGENT DISTRIBUTION HOSE AND 435962 � TETHER KIT - - uLEuo8mo December 1. cooe