CERTIFICATE OF OCCUPANCY
No: 46859 Date: 02/18/2026
THIS CERTIFIES that the building ADDITION/ALTERATION
Location of Property: 515 Maple Ln Southold, NY 11971
Sec/Block/Lot: 64.-1-26
Conforms substantially to the Application for Building Permit heretofore, filed in this office dated: 06/03/2022
Pursuant to which Building Permit No. 51113 and dated: 08/21/2024
Was issued, and conforms to all of the requirements of the applicable provisions of the law.
The occupancy for which this certificate is issued is:
- Alterations and repairs to existing single family dwelling as applied for.
The certificate is issued to: David Frawley ,Bernadette Frawley
Of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL:
ELECTRICAL CERTIFICATE: 48046 01/07/2026
PLUMBERS CERTIFICATION: Ethan Romanelli 02/18/2026
Autl on ed ignature
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
C, x TOWN CLERK'S OFFICE
cm
�y�o• �a�� SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 51113 Date: 8/21/2024
Permission is hereby granted to:
Frawley, David
26 Soundview Cir
White Plains, NY 10606
To: construct alterations/repairs to existing single-family dwelling as applied for.
replaces bp#48046
At premises located at:
515 Maple Ln, Southold
SCTM #473889
Sec/Block/Lot# 64.-1-26
Pursuant to application dated 6/3/2022 and approved by the Building Inspector.
To expire on 2/20/2026.
Fees:
PERMIT RENEWAL $252.65
Total: $252.65
Building Inspector
TOWN OF SOUTHOLD
ay BUILDING DEPARTMENT
y s TOWN CLERK'S OFFICE
o • SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 48046 Date: 7/7/2022
Permission is hereby granted to:
Frawley, David
26 Soundview Cir
White Plains, NY 10606
To: construct alterations/repairs to existing single-family dwelling as applied for.
At premises located at:
515 Maple Ln., Southold
SCTM #473889
Sec/Block/Lot# 64.4-26
Pursuant to application dated 6/3/2022 and approved by the Building Inspector.
To expire on 1/6/2024.
Fees:
SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $214.00
CO-ALTERATION TO DWELLING $50.00
Total: $264.00
Building Inspector
SO�lyo�o
Town Hall Annex Telephone(631)765-1802
54375 Main Road N
P.O.Box 1179
Southold,New York 11971-0959 �lif'COU
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICAL COMPLIANCE
SITE LOCATION
Issued To: David Frawley
Address: 515 Maple Ln City: Southold st: NY zip: 11971
Building Permit#: 48046 Section: 64 Block: 1 Lot: 26
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Electrician: Primary Electrical Solutions License No: 58071ME
SITE DETAILS
Office Use Only
Commercial Indoor X Basement Service X Solar
Residential X Outdoor 1 st Floor Pool Battery Storage
As-built Renovation X 2nd Floor X Hot Tub EV Charger
New X Addition X Attic Spa Generator
Survey Mezzanine Garage Dock
INVENTORY
Service 1 ph X In-wall Heater Recpt 44 Ceiling Fixtures 4 Smoke Detectors 5 Pump
Service 3 ph Hot Water GFCI Recpt 2 Wall Fixtures 16 CO Detectors Heater
Main Panel 200 A/C Condenser Single Recpt RecessdFixtures 18 Combo Smoke/CO 4 Transformer
Sub Panel A/C Blower Range Recpt Gas Ceiling Fan 3 Heat Detectors Salt Gen
Transfer Switch Mini Split Dryer Recpt UC Lights 16' Fridge 1 AutoCover
ARC 6 Blower Heads Switches 34 Pucks Lights Dishwasher 1 Mini Fridge
GFI SepticDisconnect Emrgency Strobe 4'LED Microwave 1 Garbage Disp.
ARC/GFI ERV Exit Lights Bath Exhaust 2 Hood 1 Dehumidifier
Other Equipment: 200A Panel 40 Circuit/31 Used , Electric BaseBoard Heat(1) 2', (3)4', (1) 6'
Notes: Second Floor Renovation, Service and Kitchen Renovation
Inspector Signature: Date: January 7, 2026
54375 Main Road +!
P_O.Box 1179
Southold,NY 11971-M9
BUILDING DEPARTMENT
`OWN OF SOUTHOLD
CERTIFICATION
Date:
Building Permit No. ��/ 3
Owner: f(aJ fe-j
(Please print)
Plumber: goehar✓d ll .
(Please print)
9
I certify that the solder used in the water supply system contains less than 2110 of 1%lead,
(Plumbers Signature)
Sworn to before me this � l
day of r-do r Vi cckt 20rn
�p
LIE'
-r�ram , ►' uG
Notary Public, County : s F E B 1 8 2026 _' `
CONNIE D.BUNCH
Notary Public,State of New York
No.01 BU6185050
Qualified In Suffolk County
Commission Expires April 14,2_ck� (�
I
`A.
Tiderunner Engineering & Design, P.C.
L�
7 Ridgewood St
Bay Shore, NY 11706 (631)-839-4824
March 5, 2023
Building Inspector
Town of Southold
53095 Main Road - E C E Q WE
Southold,NY 11751 _
J A N 2 5 2024
Re: Construction Certification
Frawley Residence Pa=EKI'q DePOK-I-11"t
TO."m Car Southold
515 Maple Lane, Southold,New York
Dear Sir or Madam:
I have visited the site during the course of the construction and have inspected and
reviewed the following work items:
1. Installed two new twelve (12) inch poured concrete post footings thirty-six(36)
inches deep
2. Removed old posts and replaced with new pressure treated 6 x 6 posts.
3. Removed existing staircase. Framed the existing opening and closed.
4. Relocated exterior door and installed new windows on south wall. All headers
were properly designed and installed.
5. Widening existing opening in an interior bearing wall and installed new header.
6. Added additional wall studs to create a sixteen(16) inch on center exterior wall
system.
7. Installed new headers over existing windows.
8. Installed new R-15 wall insulation and fire caulked all penetrations between
floors.
1
9. Installed new plywood sheathing, house wrap and siding on the exterior walls,
l
All work was completed in compliance with the approved plans and the 2020 NYS
Residential Building Code.
If you have questions please feel free to call
�,cF NEW� 4SmcerS
SCH�Jq�T�'�
o �
� v
oQ LAJW wartz,P.E.
z
77006 X,�_
�'�ROFESS�o�P
Slll3
0 g nner Engineering & Design, P.C.
S E P 1 8 2025
<.
Building®eparizme�na h�
Town of Sow-
7 Ridgewood St
Bay Shore,NY 11706 (631}839-4824
August 5, 2025
Building Inspector
Town of Southold
53095 Main Road
Southold,NY 11751
Re: Construction Certification
Frawley Residence
515 Maple Lane, Southold,New York
Dear Sir or Madam:
I have visited the site during the course of the construction and have inspected and
reviewed the following work items completed as part of a second-floor renovation
program:
1. Removed several non-bearing partition walls and replaced them with 2 x 4
partition walls and drywall and others with 2 x 6 studs and drywall.
2. Removed existing partition wall between south side bedroom and south side
bathroom replaced with 2 x 6 plumbing wall.
3. Replaced existing doors with new thirty(30)inch walls.
4. Replaced several headers in existing windows.
5. Added closet space to master bedroom
6. Added closets to two second floor bedrooms with six-foot wide sliding closet
doors.
7. Installed new headers over existing windows.
All work was completed in compliance with the approved plans and the 2020 NYS
Residential Building Code.
If you have questions please feel free to call
Sincerely,
OF NEW
•�� G.scy Y0 1
GO OC
o s i Louis Schwartz,P.E.
�Z°Fo 0Ti00 A
AR�FESSW��
ho�aOF 50(/Tyolo ` b otj - - -
# # TOWN OF{�SOUTHOLD BUIL ING DEPT.
`ycOU 631-765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING
[ ] FRAMING /STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL
REMARKS:
, f
DATE ZZs/ -2zlNSPECTOR
how*OE SOUTyo�
# # TOWN OF SOUTHOLD BUILDING DEPT.
cou 631-765-1802
�0 INSPEC 7]IROUGH
ION
[ ] FOUNDATION 1ST [ PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING
[ ] FRAMING /STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL
REMARKS:
DATE l INSPECTOR
ho�'OF SOUTyo� ' &" ' (�
-
# # TOWN OF SOUTHOLD BUILDING EPT. v`_l
CouN 631-765-1802
INSPECTION
[ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING
[ ] FRAMING/STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ _ ] FIRE RESISTANT PENETRATION
` ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL
REMARKS: Aaw ✓
tre
72 " c3P
DATE C� INSPECTOR
04 SOUTyolo 5 /// 45 L l� ee / ,�TOWWOF SOUTHOLD BUILDIN EPT. �1
631-765-1802
INSPECTION
[ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING
[ ] FRAMING /STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL
REMARKS:
141,IA
ovz�
B Cv ef
o d�
c, � /
-J- Q ta'6 CaCl AA I I -A
�7-i 7
DATE a INSPECTOR
i OF SOpTyOlo
# # TOWN OF SOUTHOLD BUILDING DEPT.
coo 631-765-1802
INSPECTION
[ ] FOUNDATION 1ST/ REBAR [ ] RO H PLBG.
[ ] FOUNDATION 2ND [ ] SULAT_IOWCAULKING
[ ] FRAMING /STRAPPING [ FINAL
[ .] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ '] FIRE-RESISTANT PENETRATION
[ . ] .ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL
O
C 0 4;
G�
REMARKS: 1 c '�X,/ 2
DATE 10 INSPECT0
FIELD INSPECTION REPORT I DATE COMMENTS
ro
FOUNDATION (1ST) ! ,,
------------------------------------
� C
FOUNDATION (2ND) M
LA
� cl,
ROUGH FRAMING& t�
PLUMBING
r
INSULATION PER N.Y. y
STATE ENERGY CODE
rj�&ffi�" SvUt�f (-&X. 7W cl-
FINAL �$ l
ADDITIONAL COMMENTS
s4F Z
e all
mAnQCD 0 btu.. rn
V3 re-fe.c job T/ IWk
�•
AA
r � O
a P� 6�
O
0
1 �t✓G iC. ca�"� � �
b
H
TOWN OF SOUTHOLD—BUILDING DEPARTMENT
fi Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
Telephone 631 765-1802 Fax 631 765-9502 https://www.southoldtownny.gov
Date Received
APPLICATION FOR BUILDING PERMIT
For Office Use Only
PERMIT NO. 1-04Building Inspector: r,t
0,
Applications and forms must be filled out in their entirety.Incomplete11
applications will not be accepted. Where the Applicant is not the owner,an R- i— N
Owner's Authorization form(Page 2)shall be completed. = IJ
fIVi OF�0,( iu� A .F
Date: 6/1/2022
OWNER(S)OF PROPERTY:
Name:David & Bernadette Frawley SCTM#1000- L�
Project Address: 515 Maple Lane, Southold, NY
Phone#: 914 420 0357 Email: dfrawley@rocketmail.com
Mailing Address: PO Box 1788 Southold, NY 11971
CONTACT PERSON:
Name:
David Frawley
Mailing Address: PO Box 1788 Southold, NY 11971
Phone#: 914 420 0357 Email: dfrawley@rocketmail.com
DESIGN PROFESSIONAL INFORMATION:
Name: Louis Schwartz Tiderunner Engineering and Design
Mailing Address: 7 Ridgewood Street Bay Shore, NY 11706
Phone#: 631 410-6838 Email: tiderunnereng@gmail.com
CONTRACTOR INFORMATION:
Name: David Frawley (home owner)
Mailing Address: PO Box 1788 Southold, NY 11971
Phone#: 914 420 0357 1 Email: dfrawley@rocketmail.com
DESCRIPTION OF PROPOSED CONSTRUCTION
❑New Structure ❑Addition BAlteration BRepair RDemolition Estimated Cost of Project:
❑Other $so,000
Will the lot be re-graded? ❑Yes B No Will excess fill be removed from premises? ❑Yes R No
1
PROPERTY INFORMATION
Existing use of property: Primary Residence Intended use of property: Primary Residence
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
R-40 this property? ❑Yes @ No IF YES,PROVIDE A COPY.
@ the'-R, _'!P"'':'r Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by
Chapter 236 of the Town Code. APPUCATION IS HEREBY MADE to the Building Department for the'issuance of a Building Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are
punishable as a Gass A misdemeanor pursuant to Section 210.45 of the New York State Penal Law.
Application Submitted By(print name): David Frawley ❑Authorized Agent @Owner
Signature of Applicant: Date:
STATE OF NEW YORK)
SS:
COUNTY OF
David Frawleyj
� being duly sworn,deposes and says that(s)he is the applicant
(Name of individual signin contract)above named,
(S)he is the Home Owner
(Contractor,Agent,Corporate Officer,etc.)
of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief;and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
day of JUNK' ,20kA �
Noti pO-U ffiE M MACARTHUR
NOTARY PUBLIC-STATE OF NEW YORK
No.01 MA6384635
tta iA't L,x [ r7 .t }�.IT!_ �!U. �jkr.0 I.; ,;T10 g`3
_ _ Qualified in Suffolk County
(Where the applicant is not the owner) My Commission Expires 12-17-2022
I, residing at
do hereby authorize to apply on
my behalf to the Town of Southold Building Department for approval as described herein.
Owner's Signature Date
Print Owner's Name
2
12I 5
��gUFEO;l�KCO Nw � � 202� BUILDING DEPARTMENT- Electrical Inspector
TOWN OF SOUTHOLD
o ` 1 Town Hall Annex - 54375 Main Road - PO Box 1179
Southold, New York 11971-0959
Telephone (631) 765=1802 - FAX (631) 765-9502
rogerr(c-southoldtownny.gov - seand(aDsoutholdtownny.aov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All information Required) Date: 11 !o LozZ
Company Name: r'edn'Ccd
Electrician's Name: C hbq 5�o �e r SL�t
License No.: M E- S8 07 f Elec. email: Er,i ti. . 5 e- tea,` •��w
Elec. Phone No: Gal 6)7 y7ao El request an email copy oft ertificate of Compliance
Elec. Address.: PD 6o,, y6' Y,g tv,4 1,-- fVy
JOB SITE INFORMATION (All Information Required)
Name: davi d FI-a wje
Address: 51S' le G��e Sow J� h/�i lli7 I
Cross Street: [M c,i n R�
Phone No.: 91q *o o357
Bldg.Permit #: 14 8C)q& email:
Tax Map District: 1000, Section: Block: Lot:
BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
K���-�.e� fi'2W.od� � o�,,-(•le�� j�yL�•�s� 0.W p°f l`.►z�es
Square Footage: 19 D
Circle All That Apply:
Is job ready for inspection?: ❑ YES � NO ❑Rough In ❑ Final
Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On
Temp Information: (All information required)
Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter#
❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead
# Underground Laterals 1 2 H Frame Pole Work done on Service? n Y N
Additional Information:
PAYMENT DUE WITH APPLICATION
voik*
1-2-
I I- 1 / i run
iT Un _r'BUILDING DEPARTMENT- Electrical Inspector
Co�t - TOWN.OF SOUTHOLD
Town Hall Annex - 54375 Main Road - PO Box 1179
o ® ;Jr Southold, New York 11971-0959
Telephone (631) 765-1802 - FAX (631) 765-9502
rogerr(Dsoutholdtownny.- ov - seand(cr�southoldtownny.gov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All Information Required) Date:
Company Name: ` � �lec�✓�"Ca Sa�� bh5
Electrician's Name: C ri rl S}o �e r '36, t,&4
License No.: E- �8 y7 / Elec. email:
Elec. Phone No: 6)7 Y7), ❑I request an email copy of t,4ertificate of Compliance
Elec. Address.: PO /hoc S 4 AGoL, NV l f A?
JOB SITE INFORMATION (All Information Required)
Name: dav►(1 FniL le
Address: .6-1 s" AiA G,"•e- So,,P4dJ AIV 111 7 t
Cross Street: tM c i n &
Phone No.: q Iq ` p 0,
Bldg.Permit#: q 8D q(o email:
Tax Map District: 1000 Section: Block: Lot:
BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
K���•e� �e�v��, .- o��le�-5 l,` �I�s ���l���es
Square Footage: 1190
C e AII That Apply:
Is job ready for inspection?: ❑ YES � NO ❑Rough In ❑ Final
Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On
Temp Information: (All information required)
Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter#
❑New Service❑Fire Reconnect[]Flood Reconnect Dservice Reconnect❑Undergroun d❑Ove rhead
# Underground
Laterals
r—' 1^11nI Frame r-iPoie Work done on Serice% �•• �v Y Additional Information:
PAYMENT DUE WITH APPLICATION ll ) I 01
c -7 at II
�� i o6�0D . gy 4 L(&( (70
PERMIT ft Address:
Switchesl� I C
Outlets
GFI's
Surface t I
Sconces
HH's ✓^ 1
r
—W
UC Lts
Fans I
Fridge HW
Ove�� W/D
Exhaust I
Smokes 1 ,
DW I Mini
Carbon Micro Generator
Combo 1 Cooktop Transfer
AC I AH Hood Service
Amps Have Used
Special:
Comments n
MAIN ROAD
I
N 72'5130'E N1F FIARRINOTON 184.98' c OA'E
cm
lem IRREGULAR W3T- FO p
i FE.0 N
Ro oL in w
Ur.
tas —
N 2S4w /x
W DIRT ORNEWAY
19'FR
1+ 1.YE
IZ 46.8T 12.0 23A d 12S N Z19W
SFOVER
d FROEM
20.9'
2STY F&O.BW
Q $ FR RES
J4&7W § #/515 sor ex
d 472 cd
PoRm
w
U.P.
m m
z
cm FE T1 OA
t OAE
u�7X NO POB9 235 FD y_y_
S 7T59'10'W NIF THOMES 184.9T GAR
9.
x
0
MAP OF DESCRIBED PROPERTY
SITUATE AT SOUTHOLD
TOWN OF SOUTHOLD
SUFFOLK COUNTY,NEW YORK
CERTIFIED TO:DAVID FRAWLEY
BERNADETTE FRAWLEY
FIDELITY NATIONAL TITLE INSURANCE COMPANY
econrama2m WNW8R00K&XLfUWW;tWawm Wft=T=osn=D=0XDRIBKr4AT=0PFWM&G0PYPo LM
nossuA+nrRue®+vR®N:mwNocamN+ar wm+n�e eooeaFvwieneEN�ovr®evn��rraaesrAtewssoeunaaaFca�mio�w.uvoa�evEtrons.
mrmzunnaouuaunorarmn�vERsa+.nrewmrteaEsrNma+wwa+s.
C0tnF 11OOR8m"cffTR x9Fuv 6. SCALE1'=W
'PE MEAueanaKsrt OPWAxNarnEASBOa OFFW00 WAWP 9fWMMPWWMm gmµ1U4oQ84.0001.00018�0
NaN.hs TMORAoomoytonmsuRMtB,%MA Moaaecna+7M20FTMPMWroMWME lxwMLm SURVEYED MAY olaD 21
ooRarseNeFexceaoFFSEresu> e resooa►rtRe noraNc
LAND SURVEY LONG
I
I
WARD BROOKS LAND SURVEYOR
11 OCEAN AVENUE
BLUE POINT, NY. 11715 ,s
(631) 576-7794 (631) 363-3179 +
WARDBROOKSO@GMAIL.COM
1 FlLE#11118
r
-TD
1-7
ECEEWE
JA N 2 5 2024
BUFMIIng Department
1OWk-I Of SOLOO9G
IXSouthold Town Building Department
P.O.Box 1179 Permit#: 48046
53095 Main Rd
Southold,New York 11971 Permit Date: 7/7/2022
(631)765-1802 Expiration Date: 1/6/2024
Parcel ID: 64.4-26
BUILDING PERMIT RENEWAL LETTER
Dated: 7/18/2024
Applicant: Frawley, David
Location: 515 Maple Ln., Southold
Work Description: ADDITION/ALTERATION
construct alterations/repairs to existing single-family dwelling as applied for.
A FEE OF$252.65 IS REQUIRED TO RENEW THIS BUILDING PERMIT.
Owner: Frawley, David
Address: 26 Soundview Cir
White Plains,NY 10606
The permit listed above has expired. No work is permitted or authorized beyond the expiration date. Please
submit the above fee made payable to the Town of Southold. Mail to the Town of Southold Building
Department, P.O. Box 1179, Southold,New York 11971
THANK YOU,
SOUTHOLD TOWN BUILDING DEPT.
6/1/2022
515 Maple Lane;Kitchen Remodel
Summary:
Remodel existing kitchen space with new cabinets, flooring, ceiling and walls.
Existing plumbing for sink to be retained. Existing Stove location and gas connection to be
retained.
Project overview:
• Remove bead board wall and ceiling covering
• Remove vinyl floor to subfloor
Install new exterior door in North wall in existing window opening as per stamped plan
drawing
• Close existing exterior door opening as per stamped plan drawing
• Close East window opening as per stamped plan drawing
• Close Pantry Door opening as per stamped plan drawing
• Remove pantry walls and back staircase as per plan drawing--the walls were bwd.
directly on existing covered porch; removing walls will return the porch to its oridinA
condition and footprint as per stamped plan drawing.
Add floor framing to stairwell opening as per stamped plan drawing.
• Install exterior siding on East wall where pantry door existed as per stamped plan
drawing.
• Replace East corner footing and post in pantry as per stamped plan drawing.
• Install electric outlets (separate permit by electrician)
• Insulate/Sheetrock walls/ceiling
• Install new kitchen cabinets, counters, back splash and tile floor
Km
4
AMENOM NT
PLU,MEEF ,CERTIFICATION
ON LEAD
160NTENTIBEFGPE
CERTII='IC�7*6F,000UPAN(;ti
SOLO .USED.ill-�6TER
SUPPL 'S1�SxEM CANNC I
EXCEED 2110 OF 1% LFA '.
'PaMING�
ALL PLUMBING UVHS ;
WATER LINES NEff
T tNG BEFORE COVERING
ELECTRICAL
WSPECTION REQUIRED
I'A
JV
M17 .1
Amendment to Building Permit# 48046 515 Maple Lane Southold NY DEC 2 6 2023
Proposed Additional Work to already open permit 48046:
Refer to included print out of 515 Maple Land second floor layout in BEFORE and
AFTER views for reference regarding work below:
NOTE: THE ROOM DIMENSION MEASUREMENTS IN THE BEFORE/AFTER
DIAGRAMS MAY VARY BY 1-2 INCHES—THAT DIFFERENCE IS DUE TO THE
SOFTWARE USED TO MAKE THE DIAGRAM. THE RAW ROOM DIMENSIONS
ARE NOT CHANGED IN THIS PROJECT, WITH THE EXCEPTION OF REMOVAL
OF THE BEAD BOARD PARTION IN MASTER BEDROOM THAT FORMS THE
EAST WALL OF THE WATER CLOSET (SEE BEFORE/AFTER)
1. Remove existing closet on East wall of master bedroom. (Before view)
2. Add needed framing for wall/doors to form new closet on East wall of master
bedroom (After view). I
, 3. Add needed framing in Sun room for wall/doors to form new closet on South wall
of Sun room (After view).
4. Remove existing closet West wall of Bedroom I (Before view)
5. Add needed framing in Bedroom I for wall/doors to form new closet on West wall
of Bedroom I (After view)
6. Remove existing closet in Bathroom I (Before view)
7. Add needed framing in Bathroom 1 for wall/doors to form new closet on in
.Bathroom. I (After view)
8. Add needed framing to Bedroom 2 for wall/doors to provide better door access to
existing closet on South wall of Bedroom 2 (After view)
9. Close existing door to existing closet on North wall of Bedroom 2 (Before/After
view).
10. Reframe North entry wall of Bedroom 3 to move entry-door from hallway to
Bedroom 3 2.5' to the west. (Before/After views)
14.Add needed framing in Bedroom 3 for wall/doors to form new closet in
Bedroom 3 on East wall of Bedroom 3 (After view).
12,.Remove existing bead board partition wall that forms the East wall of existing
Water Closet in Master Bedroom. Remove all existing plumbing fixtures/piping
for the water closet. (Before view).
13. Remove all existing plumbing fixtures in Bathroom 2. (Before view)
14.Reframe the East wall of Bathroom 2 to include entry door from Master Bedroom
(After view)
15.Reframe existing bead board partition wall that forms the North wall of Bathroom
2. Close existing hallway door into Bathroom 2. (Before/After view)
16.Add new shower, sink, toilet fixtures, and required plumbing drains, vents, supply
lines.in positions shown. (After view)
17. Replace existing 4' section of cast iron main drain pipe that drains plumbing
fixtures from Bathroom 2. The existing 4' section of pipe is cracked. Proposed
work is to remove cracked section and replace with PVC, to connect to the
fixtures in Bathroom 2.
Laundry
MOLhInC
14'-11'
15'
TO BE
15'•5'
T. REMOVED
�,•1. Ip
ADD FRAMIN61
DOORS
15'-5" 1 y-5•
k k
r
B'-2'm
MASTER BEDROOM
5"
MASTER BEDROOM
NORTH Ewswg NORTH BEDROOM 1 Y 5•,6"—N 'Water Llo et" BEAD BOARD y- BEDROOM 1
7y
PARTION NALL
,tJ /
TO BE
REMOVED -5.4^-.q 6LO5ET —TO BE
•- I REMOVED NAtLi REFRAME
D UP J D FFF
UP .�/i
MASTER BEDROOM
NEWLAYOUT
—15'•T' - BATHROOM 1'^ BATHROOM
tr k m
3'-1' 8A7HROOM7 tr B'•1•
BATHROOM 1
BATHROOM 1 I is
v
11'-T• 2'-2"
BEDROOM 2
BEDROOM 2 BEDROOM 5 ppp ADD FRAMING/
DOORS v
� \ BEDROOMS
4' q 14'
ADD FRAMING/J tr
174' DOORS \
BEDROOM
' - I
BEFORE AFTER
t �
AM ND �NRT
Amendment to Building Permit # 48046
515 Maple bane Southold NY
f `1( f i'�• r�t
Proposed Additional Work to already open permit 48046: , ,}
MAR - 7 2024
Refer to included print out of 515 Maple Land second floor layout in Bl✓T'!J%Td.- ^.,
AFTER views for reference regarding work below: .�,Y r.• .
New Work
Below are additional work items for the permit.
I realized when performing the work approved in January 2024 (see below), that I
needed to remove 3 additional bead board partitions, and replace with a standard 2x4
wall construction. The room dimensions are essentially unchanged by the work (the
proposed standard wall framing reduces room dimension by —2-3 inches)
New Proposed Work additions are:
1. Remove bead board wall on west side of Bathroom 2 ( see before and after
diagrams)
2. Replace removed bead board with 2x6 framing and sheet rock. 2X6 is to
accommodate new sink plumbing
3. Remove bead board wall on north side of Bathroom 3 ( see before and after
diagrams).
4. Replace removed bead board with 2x4 framing and sheet rock.
5. Remove bead board wall on east side of Bedroom 2 ( see before and after
diagrams)
6. Replace removed bead board with 2x4 framing and sheet rock.
Work approv d-on`permit in January' 024:
Below are additions to pen-nit that w&e appro�led in January of 2024
/Remove existing closet on East wall of waste edroom. (Before view)
2. Add needed framing for wall/doors to form new closet on East wall of master
bedroom (After view). ,
3. Add neede framing in Sun room for wall/doors to form newcloset on South wall
of Sun room (�fter view).
4. Remove existing closet West wall of Bedroom 1 (Before°view)
5. Add needed framing in Bedroom 1 for wall/doors to,f®rm new closet on West wall
of Bedroom 1 (After view)
6. remove existing closet in Bathroom 1 (Before//iew)
7. Add needed framing ih\Bathroom 1 for wall/doors to form new closet on in
Bathroom 1 (After view`),
8. Add needed framing to Bedroom 2 for/ alUdoors to provide better door access to
existing closet on South w4l of Bedroom 2 (After view)
9. Close existing door to existing closet on North wall of Bedroom 2 (Before/After
view).
10. Reframe North entry wall of Bedroom 3 to move entry door from hallway to
Bedroom 3 2.5' to the west./(Before/After views)
11.Add needed framing in Bedroom 3 for wall/doors to form new closet in
Bedroom 3 on East wall of Bedroom(After view).
12.Remove existing bead'board partition wall that forms the East wall of existing
Water Closet in Masier Bedroom. Remove all existing plumbing fixtures/piping
for the water closet. (Before view).
13. Remove all existing plumbing fixtures in throom 2. (Before view)
14.Reframe the East wall of Bathroom 2 to include entry door from Master Bedroom
(After view,)`
15.Reframe existing bead board partition wall that rms the North wall of Bathroom
2. Close"existing hallway door into Bathroom 2. ( efore/After view)
16.Add new shower, sink, toilet fixtures, and required p umbing drains, vents, supply
lines in positions shown. (After view)
17. Replace existing 4' section of cast iron main drain pipe hat drains plumbing
,fxtures from Bathroom 2. The existing 4' section of pipe 's craciced. Proposed
work is to remove cracked section and replace with PVC, t, connect to the
fixtures in Bathroom 2.
!i
i!
i
7
N�-a
"\ I
R
•� WALL5 TO REFRAME
TO REFRAME '
wo/k ��
�-
��
ii
i
N e� I` — `
//
s'��1�� _- - _
U �\
I�
\-@- -
1 I _�'
�\
�`'
`��
�� 1
i
V N
c—3 O -
-A. N
r �l CD
14'-11• L�� ��'
ly NOTE B
NOTE A
II ADDFRAMINGI II
DOORS
NOTE G ,s,•s.
H Y
fV
MASTER BEDROOM 1Y B•
NORTHBEDROOM, MASTER BEDROOM
It q NORTH
N.—� S'•6°—M BEDROOM 1
m C �1 NOTE a
WALLS TO REPRAME ^
D OF MASTER BEDROOM, C ,UP {\�`
NEN"AYOUT NOTE E
SATHROOM2 m BATHROOM .BATHROOM 2
o- '4
BATHROOM 1
t BATHROOM 1 i i loset. Goeet
4'4• �I
BEDROOM 2
ADD FRAMING/ BEDROOM 2ADD
1
CLOSET DOORS < DOORS MINGI
N � BEDROOMS ¢ CLOSET DOORS a
ry BEDROOM 9
ADD PRAMING�_. Y 14' i '4 19 11'
DOORS \ BEDROOM DOD FRAMINGI�.
\\ DOORS
\\ BEDROOM
REVISION 1 REVISION 2
Jan 2024 Nov. 2024
TO BE
Closet REMOVED
EII
7
L
MASTER BEDROOM
NORTH BEDROOM 1 UstIng
5.61. 'Water Clo 3et" BEAD BOARD
N FARTION WAIL
TO BE
REMOVED CLOSET TO BE
Closely REMOVED
0 1 u I p
HROOM 2
BATHROOMI
2'.2"
ON V
BEDROOM 5
BEDROOM 2 Y C::D
C\j
CD
LLD
ORIGINAL LAYOUT
r
Building Permit: .51113 AMENDMENT
Address: 515 Maple Lane Southold NY
Owner: David Frawley
914 420 0357
Below are amendments to the previously approved 2"'floor renovations.Included are 3 drawings,the
original 2"floor layout;the first approved revisons to 2'floor layout(Jan 2024), and,the current(and
final) layout(Nov. 2024).
The changes to the previously approved plan are (see drawing"Revision 2,Nov. 2024")
Note A: The closet size and location change: revised to 8'xT,with one 30": door. Previous revision it
was 21"x 15'with accordion doors.
Note B: Retain original window.The Jan 2024 revision removed the original window that opened into
the existing sun room space, in order to facilitate the closet proposed.This revision keeps the original
window location, since the closet layout leaves room for it.
Note C and Note D: The Jan 2024 revision showed new closets to be framed in the Sunroom and
Bedroom 1. These closets will not be built.
Note E: the Jan 2024 revision showed a corner shower in the bathroom.A rectangular shower was
installed, and a small closet framed at west end of shower enclosure. Plumbing rough in inspection for
shower was approved by building department in spring of 2024
a
NOV 2 0 2024 ....
N
BUILDINO DEPARTMENT DATA: 00
ABBREVIATIONSEN_ KE VATI Classification/Floor ,area 00_
ACQ ALKALINE COPPER QUATE Floor RNAZY LVL LAMINATED VENEER LUMBER Level Existing Proposal Total
ACT ACOUSTICAL TILE MAX MAXIMUM Cellar(Finished) O
AL ALUMINUM MIN MINIMUM j O O
ALT ALTERNATE MRB MARBLE
AFF ABOVE FIRST FLOOR me MARBLE SADDLE U
N 1st Floor p O O
ASF ABOVE SUBFLOOR MTL METAL
n 2nd Floor O O O '?
A.S. ALUMINUM SADDLE NA NOT APPLICABLE 11- Total O O OM P L = = -
A LAN
A.P.B. ANTHONY POWER BEAM NIC NOT IN CONTRACT
B.C. BRICK COURSES NOM NOMINAL Q
Garage O O O ' "• 3
BD BOARD NR NOT REQUIRED O .
i
BOT BOTTOM NTS NOT T-O SCALE Front Porch o 0 O
BLDG BUILDING OC ON CENTER
EN BOARD OCC OGGUIPANT S u Rear Porch O O O s *,
C 8B CEMENT BACKER BO ( ) Y, N "
CL CLOSET OH OVERIHANG ,{
NDecks O 0 O
CLG CEILING PART. PART11TON _ _ _ UTH LD9
CLR CLEARANCE) PC POURIED CONCRETE
COL COLUMN PT POINT r - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - �`'L4r='=I
CONC CONCRETE PKT POCKET
CMU CONCRETE MASONRY UNIT RAD RADIUS 5'-8"
Construction Note:
CT COLLAR TIE REQ. REQUIRED 12" D{am PC Post Ft
g Existing Pantry was constructed over existing roofed over porch. Q o
CJ CEILING JOIST REV REVISiION(S)
w/Treated 6 x 6 Post Removal of the pantry is to bring back porch to original condition H ,_..
CANT CANTILEVER RM ROOI`"I - n PB Post Base
CMD CARBON MONOXIDE DETECTOR RR ROOF RAFTER 2 x 8 FJ @ 15 OC ; _ , z-
(2) 2 x;$ (Min)' Remove Ex. Pantry Walls, Stairs and Stairwell Walls to return unheated N
oz
DIA DIAMETER R/R REMOVE AND REPLACE ; ; � Match Eic Hdr ( ►-�.
DIM DIMENSION SEC SECTION ; ,
OR DOOR SF SQUARE FEET ; I , , , , � ' pantry area to original open covered porch footprint O
DTL DETAIL Sim SIMILAR Edge of Roof Over Remove Ex. Pantry ' ' : 11 =
DWG DRAWING SQ SQUARE ' 1 , f
and Stairs ' II U Q
ON DOWN STL STEEL ; ,
� ' ' ' ' ' Limit of Existing Porch
EA EACH SO SMOKE DETECTOR ' ' ��
� , � � � Framing Note:
EL ELEVATION STD STANIDARD I Close U Ddor
P , , ; ; ; �� Close Up Door Windows do not Require Sill Plate. Frame
EQ EQUAL TC TOP OF CURB �^ x Wall Studs from Header to Sill
EX EXISTING TEL TELEPHONE
D I R301.2.1.1 (2020 Residential Code of New York State)
EXH EXHAUST THK THICKNESS ; i
v ; c Design Criteria Construction in regions where the basic wind speeAs7
EXT EXTERIOR TOS TOP OF SLAB m
� N � Close Up Door exceed from Figure R301.2(4) equal or exceed i � ?fl`7`)
EF EXHAUST FAN TX TOILET EXHAUST , x 130 miles per hour shall be designed in accordanceF
E-' J `�
EW EGRESS WINDOW TXF TOILET EXHAUST FAN 0'
Fr_ FIRE CODE TYP TYPICAL ; ;
FLOOR RAIN TEM TEMPCORED I 1, with one of the following: ^yr;
FD D � Fill Opeining w/2 x 4 � EUIi_Dtiv��DEPT �
Plans have been designed TOE OF SOUTHOL_
FIN FINISH ED TEMP TEMPORARY - Studs 16"Or- a
( ) � in accordance with: 2020 New York State Residential Code �
FLR FLOORING) LON UNLESS OTHERWISE NOTED '
FPSC FIRE PROOF SELF CLOSING VIF VERIFY IN FIELD ' ' ' ' Z
WC ATER CLOSET ,3-4 CLIMATIC $ GEOGRAPHIC DE-SIGN CRITERIA:
FT FOOT PEET)
m FJ FLOOR JOIST WR WATER RESISTANT , Remove Ex. Window (Table R301.2(1) U
Category:Exposure d Ex Q
GA GAUGE ; ; � Install new 2868 Ext Door Win p g �'� B a
GALV GALVANIZED
Ground Snow Load: 20 PSF O
GFI GROUND FAULT INTERRUPT I n
Wind Speed: 130 mph 3 sec Gust x
GL GLASS
GWB GYPSUM WALLBOARD E-+
110 fastest mile �
HC HOLLOW CORE Special Wind Region: NO O I New Treated 2 x 4 �
HOW HARDWARE Sill Windborne Debris Zone;
HM HOLLOW METAL NO W r�
HOR HORIZONTAL APP VIED AS NOTED _ Seismic Design Category C O U w O
HP HIGH POINT �..� Z
HT HEIGHT DATE:, B.P.;t
HVAC HEATING/VENTILATION/AIR CONDITION a Weathering
Severe ^ C)
IN INCH FEE: BY: D Frost Line Depth: 36 inches
NOT IF`Y BUILDING DEPARTME T AT ° ►�
INT INTERIOR Termite Infestation: Moderate to Heavy �
765-18102 8 AM TC 4 PM FOR THE Subfoar to Match Ex. +- O w
JT JOINT FOLLOWING INSPECTIONS: �U
INV INVERT
Decay Probability: Slight to Moderate
1. FOUNDATION - TWO REQUI ED Uj �°
KIT KITCHEN FOR POURED CONCRETE
I r Door/Window Opening Filling Detail
LAV LAVATORY Winter Design Temperature:
wFRAMING15 W a
� 8'-0"
2. ROuH - & PLUM ING 2 x e FJ @ 16 OC - Scale 1/2"= T w
b. INSWLATION 2o'-a° Ice Shield Underlayment Required Valleys and Perimeter Z
4. FI';AL - CONSTRUCT!^N MUTT Flood Hazard Exempt w
BE CO%::'L_Tc :..0.
ALL CONSTRUCTION SHALL MEET THE Joist Hanger Air Freezing Index 500 r--I
REQUIREMENTS OF T HE CODE OF NE4N Mean Annual Temp 51 U
YORK STATE. NOT RESPONSi 'E FOR
DESIGIN OR CONSTRUCTION ERRORS. , , g MIN. DESIGN PRE55URE DP RATING:
Floor Opening Fillip Detail �4
Windows ZONE 4 DP 25 p
Scale 3/4"= T
COMPLY WITH A L CODES OF Doors ZONE 5 DP 30 �' x
lNEW YORK STATE TOWN CODES Deck Post Centered on Footing N ZONE 1 DP 25
S REQUIRED AND uJNDIT 13
IONS OF Steel Post Base `� U
ry crl ZONE 2 DP 30 W O
Con
100 ZONE 3 DP 30 Q
�.� ;i;~`_.V i V't'r'i� µ„ •�: BOARD
i�iD
Treated 2 x 8 Rim Joist (4 ZONE 1 DP 20
N N OM ZONE 2 DP 45
Treated 2 x 8 DJ
Legend ,,;;✓; Lu I3-v,; „ ' TEES Floor Plan ZONE 3 DP 45
Existing Walls to Remain �� v The ;plans have been designed in accordance Zb118 Diagram :{ ..
with`the 2020 Residential Building Code.
Existing Walls to be Removed r -_ _ _ _ _ : -_
` J AVV nVVO ic
Gravel Base -''. .d l _
New Walls and Partitions
s
4 �
Insulation • mvicsiz -
m -` O
14" Diam PC Post Ftg CA
Door = 80 A0 V� 11 Internar -
36" Deep Min a qlc ®ZQrrneter ne w
Window -- [— Zone Zone
Structural Beam -
ELECT Ic�h Minimum Uniform) Distributed Live Loads: Table R301.5
Outlet t ,pL GTIOh! nQuIRED USE LIVE LOAD DEAD LOAD N
CV
Exterior Balconies 60 psf 10 psf L O
w N
GFI Outlet GFI PLATE 1'-2" Decks 40 psf 10 psf
Passenger Vehicle Garages 50 psf as per plan N
�
?TWO Is d ATTICS without Storage 10 psf 10 psf j;
Switch
A 3LOCK O• FILLER BLOCK Porch Post Footing Detail ATTICS with Storage 20 psf 10 psf Z Q a z Q
Ceiling Fixture t^,,%I exterior lighting a Scale 1 "= 1 ' ROOMS other than Sleeping Rooms 40 psf 10 psf a A 3
ONE 16 d
installed,replaced or B70 LOCK ER 16 d """' Sleeping Rooms
Exterior Fixture ��C�I1fO TO FILLER d R 11GEI STEEL Stairs 40 30 psf 10 psf SCALE: Q Q U
-�{ repaired shag led 12" o.C.
to Chapter 172 BLOCK 2 A? TO SPACER P p
STUD Guardrails and Handrails 200 psf 10 psf 1/4 =
Smoke Detector ;� lof the Town Code s°vI�L 12 psf for Attic t�0
yE Live +Ground Snow Load 20 psf 15 psf for Cath
GO Detector O 2X TOP PLATES OVERLAP AT Q
OOR>00 TWO 2 X 4 CORNER LOCKING WALLS ALLOWABLE DEFLECTION: Table R301.7'
TOP PLATES
WALL WOOD BACKER STRIP TOGETHER
16 d 12"O.C. STUDS 1 X OR V2" PLYWOOD, yy
Vent ® 16d STAGGERED NAILED IN PLACE CRIPPLE \ Structural Member Allowable Deflection
STAGGERED BEFORE EXTERIOR Cp D CONTINUE \ + V
12 O C sGL SHEATHING APPLIED COMMON \\\ Rafters having slopes greater than 3/12 with no finished �`� 77006
Vent/Light VERTICAL 'LATEWALL STUD
•IOd SPACING ceiling attached to rafters LJI80 FESSICNP
6
Interior Walls and Partitions
(� THREE 16 d � d R WALL Floors and Plastered Ceilings H�80 DWG. NAME:
Ceiling For \X/ TO FILLER STUD DOUBLE 2X
BLOCK / HEADER WITH 9 �O
10 d TOE- f +/s" PLYWOOD v
NAILE4 _ SPACER All other Structural Members
TO SOL SOLE - BETWEEN Exterior Walls w/plaster or stucco H/360 SHEET
TRIMMER
STUD Exterior Walls-Wind Loods(a)w/Brittle Finishes L/240
KING STUD Exterior Walls-Wind Loods(a)w/ Flexible Pinishes L/120 DWG. NO.:
SOLE P
E CORNER BLOCKING DETAIL Note: L= Span Length H= Span Height
INSULATED WALL DETAILS NOTE
ING PARTITION TO WALL a. The Wind Load shall be permitted to be taken as 0.7 times the a
STUD A TO HAVE GAME NAILING I CONNECTION Provides maximum nailing surface on interior and exterior 2X WALL STUDS
TO FILLER BLOCK AS STUD a walls. TOP PI Component and Cladding loads for the purpose of the determining C; 1
TOP PLATE FRAMING DETAIL deflection limits herein
CORNER POST 2X4 BEARING WALL--HEADER DETAIL PAGE 1 OF 2
It
N
GENERAL NOTES TABL.ER402.2 MINIMUM SPECIFIED COMPRESSNE STRENGTH OFC.ONCRETE RIDGE STRAP DETAIL TYP WALL/WINDOW AIR SEAL 00
-- — FIRE/SMOKE DETECTION GIRDER TO S.S.P. COLUMN IT
TYPE OR LOCATION OF CONCRETE CONSTRUCTION Q1
a.ALL CONSTRUCTION TO CONFORM TO ALL STATE AND LOCAL CODES. a. 1INSTALL SMOKE&CARBON MONOXIDE DETECTORS AS SHOWN ON PLAN. MINIM1UM SPECIFIED COMPRESSNE INSTALLATION @ 16"O/C 00
b.THESE DRAWINGS DO NOT INCLUDE COMPONENTS NECESSARY FOR CONSTRUCTION SAFETY. b.SINGLE&MULTIPLE STATION SMOKE ALARMS ARE ALSO TO BE INSTALLED IN CELLAR AND SHALL STRENGTHa(fc) LSTA24-980 lbs. UPLIFT 0 ^
CONTRACTORS ARE SOLELY RESPONSIBLE FOR SUCH COMPONENTS. BE INTERCONNECTED SO THAT THE ACTUATION OF ONE ALARM WILL ACTUATE ALL ALARMS, IN ° a
c.BUILDER TO OBTAIN CERTIFICATE OF OCCUPANCY(C.O.) ACCORDANCE W/R314.POWER SOURCE FOR SMOKE ALARM SYSTEM IS TO COMPLY W/R314, weatherngPotedot b o ' �p
d. BUILDER TO CARRY WORKMAN'S COMP. INS. IN AMOUNTS AS REQUIRED BY LAW. ° ° a
C.AT LEAST ONE CARBON MONOXIDE ALARM IS TO BE PROVIDED IN EACH DWELLING UNIT,1N THE Negllglble Moderate severe ° o
e.ALL WORK SHALL BE FULLY GUARANTEED FOR ONE YEAR AFTER C.O. IS ISSUED. IMMEDIATE VICINITY OF BEDROOMS ON THE LOWEST FLOOR LEVEL.THE CARBON MONOXIDE Basemertwalls,foundoHonsandoiherconcre+enofe-posedtotheweather
f.OWNER TO BE RESPONSIBLE FOR FINAL SURVEY AND COSTS AS REQUIRED BY BUILDING ALARM IS TO COMPLY W/UL 2034 AND UL 217, AND IS TO BE INSTALLED AND MAINTAINED IN 2soo 2 soo 2500c ' •09� +�
DEPARTMENT. ACCORDANCE w/ MANUFACTURER'S INSTRUCTIONS. `� -ING GYPSUM BOARD AS AIR BARRIER
g. ENGINEER HAS NOT BEEN RETAINED FOR ANY FIELD SUPERVISION OR INSPECTION. Basement 2Soo 2SOo 2,.�ooc Pv
h.DRAWINGS ARE NOT TO BE SCALED BY CONTRACTOR.ANY DISCREPANCIES ON DRAWINGS ARE TO d.EXTERIOR WALLS& INTERIOR LOAD BEARING WALLS TO HAVE FIREBLOCKING IQ�G
Bork ex rt walls,foundation weather
walls,exterior walls and other verMcal concrete S.S.P. CAPS- KLCC SERIES CONTINUOUS BEAD OF SEALANT
BE BROUGHT TO ENGINEER'S ATTENTION IMMEDIATELY PRIOR TO CONSTRUCTION. wakexposedtotheweather 2500 3,000d 3,000d
16d NAILS ALL HOLES
L THIS ENGINEER HAS BEEN RETAINED FOR WORK SHOWN ON THIS DRAWING ONLY. ENGINEER IS NOT ELECTRICAL NOTES Parches,carport slabs and steps exposed to the weather,and gaeoge floor slabs 2500 3,000d 3.500e CONTINUOUS BEAD OF SEALANT
RESPONSIBLE FOR OTHER ALTERATIONS AND CONDITIONS.
j. DESIGN IN COMPLIANCE W/2020 RESIDENTIAL CODE OF NYS, 2020 ENERGY CONSERVATION CODE a.ALL WORK SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE AND LOCAL UTILITY CO. CONTINUOUS(MINIMAL EXPANDINGM
TYPICAL FRAMED OPENING FOAM AT
OF NYS,WFCM 2018&AISC/SEI F7-05 b.ON NEW WORK BASE BID ON 200 AMP SERVICE. For 9l:1 pound per square Inch=6805kPo. WINDOW PERIMETER
c.ALL WIRING TO BE MIN. 14 AWG. 5ffia+2adayspsl. `� +
d. CONVENIENCE OUTLETS TO BE 18"A.F.F.,UNLESS NOTED OTHERWISE. reng WNAILS METALSTRAP CAP
SITE NOTES e. PROVIDE GROUND FAULT INTERRUPTER OUTLETS AS PER CODE. PATE
b.See Table R3012(1)for weathering patenhaL AT 8"o c. WINDOW UNrr AS AIR BARRIER
OVER HEADER 70P
f. ELECTRICAL CONTRACTOR TO PROVIDE HOOKUPS FOR HEATING AND AIR CONDITIONING SYSTEMS. c.concrete In these lacaeons that may be subject to freezlna and thawing during construction shall be alr-emmolnedl concrete PLATE CONTINUOUS MINIMAL EXPANDING FOAM AT �. • r '
a. PITCH GRADE AWAY FROM BUILDING, g.ELECTRICAL CONDUCTOR PENETRATIONS THROUGH BUILDING STRUCTURAL COMPONENTS MUST In accordance with Foot"d. n WINDOW PERIMETER
FRAMING
b. PROVIDE DRY WELLS AS REQUIRED. COMPLY w/SECT.E3402. -`
d.Concrete shall beair-enfralned.Total air content(percent by volume of concrete)shah not F lase than 5 percenrt or more CUPS -
C.ALL TREES WITHIN 15'OF CONSTRUCTION TO BE PROTECTED. h. PROVIDE MAINTENANCE CLEARANCE AROUND CIRCUIT BOX,BOILER,ETC. SEE SECT. E3405. than 7 percent. I °° BOTH CONTINUOUS BEAD OF SEALANT
d.ANY LANDSCAPING DAMAGED BY CONSTRUCTION OPERATION I.ELECTRICAL CONTRACTOR TO COORDINATE WITH OTHER TRADES. x m FOR 2X8" SIDES
SHALL BE REPLACED AS REQUIRED. e.See Section R4022 for maum came n ous materials content.rt. LINTEL
f.For garage floors with a steel troweled flnlsh,reduction of the LINTEL
e.ALL CURBS,SIDEWALKS, ETC. DAMAGED SHALL BE REPLACED. ga H total concrete
to
sPhan4,00 onotlessthan ATTIC EAVE AIR SEAL USE ° MEMBERS CONTINUOUS BEAD OF ADHESIVE °.'t"•.r
3 percent is permitted if the specified compressive strength of the concrete Is Increased to not less than 4,000 psi. SNAILS ° °°
EACH END,
EXCAVATION NOTES INSULATION NOTES INSTALL 1"RIGID INSULATION CUT TO FIT BETWEEN THE RAFTERS.FOAM FOR 2x°• °o TREATED
TRIMMSEAL BOTH SIDES ALONG RAFTER WITH EXPANDING FOAM SEALANT. LINTEL ° STUDS q
a.EXCAVATION CONTRACTOR TO EXCAVATE:TRUE TO LINES AND GRADES DOWN TO TABLE R401.4.1 PRESUMPTIVE LOAD-BEARING VALUES OF FOUNDAMOMI HATERIALSa MAINTAIN EQUAL VENT SPACE FOR LENGTH OF RIGID INSULATION USE EIGHT ° sTws CONTINUOUS BEAD OF SEALANT
a.ALL EXTERIOR WALLS,ROOF& FLOORS OVER UNCONDITIONED SPACES SHALL BE o
SPECIFIED LEVELS. INSULATED. ALL INSULATION TO BE FIBERGLASS. FOIL FACE WITH FOIL ON WARM / YNAILS
b.ALL TOP SOIL TO BE STOCK PILED FOR FUTURE USE.ALL EXCAVATED GOOD / EACH END TREATED ~
SIDE. CARE SHOULD BE NOT TO TEAR FOIL VAPOR BARRIER. GLASS OF MATERIAL LOAD-BEARING / ° ^�
MATERIAL NEEDED FOR BACK FILL,TO BE STOCK PILED SEPARATELY, NOT NEEDED b.ACOUSTICAL INSULATION TO BE PROVIDED IN WALLS,FLOORS AND CEILING AROUND / SILL PLATE
MATERIAL AND UNACCEPTABLE MATERIAL 1-0 BE LEGALLY REMOVED FROM SITE. ALL BATHROOMS AND MECHANICAL ROOMS. PRESSURE(pounds per square foot) r 3'NAILS CONTINUOUS BEAD OF SEALANT Q Z
c.BACK FILL SHALL BE PLACED IN 12" LIFTS&COMPACTED TO 95%, OF MODIFIED Crystalline bedrock 12,000 INSTALL 1°RIGID / AT 12.O.C. °° TREATED
c. PROVIDE PERIMETER INSULAT►ON AS PER CODE AT ALL FOUNDATION WALLS. TO CO INSULATION VERTICALLY VENTED BOTTOM PLATE O
TO CONNECT INSULATING AIRSPACE o
PROCTOR DENSITY. Sedimentary and foliated rock 4 000 FULL- O
d. R-VALUES ARE SHOWN ON SECTIONS. � SHEATHING TO RIGID ATTIC
/ METAL JOIST
REINFORCING NOTES e. MOISTURE VAPOR RETARDANTS ARE TO INSTALLED ON THE WARM-IN-WINTER SIDE Sandy gravel and/or gravel (OW and GP) 3,000 INSULATION BAFFLE. INSULATION LENGTH HANGERSOR O
FOAM SEAL BOTH JOINTS / WALL TREATED FRAMING CLIPS
OF INS. IN ALL WALLS/FLOORS/ROOFS/CEILINGS IN ACCORDANCE w/SECTION R322. Sand,silty sand, clayey sand,silty gravel and clayey gravel Q
STUDS CRIPPLE
f.INSULATION MATERIAL IS TO COMPLY w/SECTION R302.10 AND IS TO HAVE A FLAME /
a. ALL REINFORCING BARS TO BE OF THE DIAMETER SHOWN DEFORMED INTERMEDIATE (SW,SP, SM, SC GM and GC) 2,000 / STUDS-NOT
GRADE NEW BILLET STEEL CONFORMING TC ASTM A 615 GRADE 60 HAVING A DESIGN SPREAD INDEX NOT TO EXCEED 25 w/A SMOKE DEVELOPED INDEX NOT TO EXCEED ' / — — FOR DOORS
450.TESTING METHODS MUST COMPLY w/ASTM E84 STD OR UL 723.ALL EXPOSED
b.TYPICAL COVER FOR
R ALL REINFORCING BARS BE THREE(3) INCHES FOR BARS Clay, sandy clay,silty clay,clayey silt, silt and sandy silt / Q
STRENGTH OF 60,0 PSI. INSULATION ON ATTIC FLOORS ARE TO HAVE MIN.CRITICAL RADIANT FLUX OF 0.12 (CL, ML, MH and CH) 1,5000 / GIRDER/POST/FOOTING CONN.
PLACED AGAINST EARTH AND 211 FOR BARS PLACED AGAINST FORIMS UNLESS WATT/CM.TESTING TO BE CARRIED OUT AS PER ASTM E970 STD.EXTERIOR
OTHERWISE SHOWN. INSULATING FINISH SYSTEM TO COMPLY w/R703.9. /
GIRDER
c.ALL BARS TO BE CONTINUOUS UNLESS SPECIFIC LENGTHS ARE SHOWN.ALL SPLICES NAILING SCHEDULE: Table Table 602.30)2020 IRC
CONTINUOUS BEAD
TO BE FORTY(40) BAR DIAMETERS MIN. OF SEALANT GIRDER TO S.S.P. COLUMN DETAIL'A'
d.WELDED WIRE:FABRIC(WWF)TO BE 6" x 6"SPACES,#10 x#10 GAUGE WHICH SHALL WINDOW AND DOOR NOTES Note: This schedule does not include nailing for metal framing stralps(see section 1 1/2"RIGID
CONSIST OF COLD DRAWN MEMBERS HAVING AN ULTIMATE STRENGTH NOT LESS THAN a.ALL WINDOWS AND SLIDING GLASS DOORS TO BE VINYL CLAD WOOD WITH for strapping and requirement's section for rough opening framing INSULATION KCC SERIES COLUMN CAP
70,000 PSI.WWF TO BE PLACED AS SHOW14 ON THE PLAN. INSULATED GLASS,SCREENS&LOCKS AS MANUFACTURED BY ANDERSEN OR requirements).
O O
tOd NAILS ALL(HOLES [~
e.ALL REINFORCING TO BE SECURELY FASTENED TO RESIST MOVEMENT DURING APPROVED EQUAL SIZES AND TYPES AS INDICATED ON PLANS. UNLESS All nailing is a general specification it applies unless otherwiis: noted. WOOD POST' Z
CONCRETE PLACEMENT. OTHERWISE NOTED.
f. WELDED WIRE FABRIC OF EQUIVALENT STEEL AREA MAY BE SUBSTITUTED FOR ANY b.ALL EXTERIOR DOORS TO BE INSULATED METAL,AS MANUFACTURED BY PAU SERIES POST ANCHOR
Joint Description No.of Nails Nail Spacing O GRADE
REINFORCING BAR GRID. BENCHMARK, STANLEY OR EQUAL. SIZES AND TYPES AS INDICATED ON PLANS. D
FULLY WEATHER-STRIPPED,LOCKS.UNLESS OTHERWISE NOTED. ROOF CEILING FRAMING C) 0 ,a/8°GALVANIZED LAG I
CONCRETE NOTES c. ALL INTERIOR DOORS TO BE 1 3/4"THICK,HOLLOW CORE, FLUSH BIRCH,U.O.N.ALL GIRDER TO CONCRETE PIER DETAIL BOLTS(4) 1 CONCRETE FOOTING Z
a.ALL CONCRETE TO BE f'c= 3,500 PSI @ 28 DAYS UNLESS OTHERWISE NOTED. DOOR JAMS AND BUCKS TO BE CLEAR PINE. ANCHOR BOLT O
-CONC.STEPS TO BE 3,500 f' c @ 28 DAYS Rafter to To Plate(Toe-Nail) (3)10d Common Per Rafter /8"%°/yCx3 1/2"LONG LAG BOLTS
b.ALL EXPOSED CONCRETE TO BE AIR ENTRAINED. CONTINUOUS WELD
c. SOIL VALUE ASSUMED AT_1 TON PER SQ. FT. AT DEPTHS NOTED. SOIL CONDITIONS ENGINEERS NOTE - FOR ADDITIONS &ALTERATIONS ONLY Ceiling Joist to To Plate Toe-Nail (3)8d Common Per Joist 6" A
TO BE VERIFIED PRIOR TO CONSTRUCTION.WATER FRONT OR PROPERTIES IN CLOSE Ceiling Joist laps over Partition (Face-Nail) (3)16d Common Each Lap a
PROXIMITY TO BEACH,CANAL, WATER,ETC.TO PROVIDE THIS OFFICE WITH TEST THE ENGINEER HAS BEEN RETAINED TO DESIGN AN ADDITION T0,RENOVATE OR LEGALIZE THIS 0 0
HOLE DATA BY LICENSED OR CERTIFIED SOIL MECHANIC. EXISTING STRUCTURE. Ceiling Joist to Parallel Rafter(Face-Nail) Table R802.5.2 Each Lap STA DARD BASE PLATES& CAPS RAFTERS TO RIDGE CONNECTION
d. BOTTOM OF EXTERIOR FOOTINGS TO BE 3"-0" MINIMUM BELOW GIRADE. E--I
e.ALL FOOTINGS TO REST ON VIRGIN UNDISTURBED SOIL. BEFORE DESIGNING BEGINS,THE ENTIRE STRUCTURE IS MEASURED AND EXISTING CONDITIONS ARE Collar Tie to Rafter(Face-Nail 3 10d Common Each End 4 UPLIFT
8751bs.
f. STEP FOOTINGS DOWN AS REQUIRED. MAXIMUM STEP FOOTINGS SHALL BE ONE DRAWN. THE BUILDING STRUCTURE AND ITS STRUCTURAL INTEGRITY ARE VISUALLY INSPECTED AND 1 POST ANCHOR DETAIL UPLIFT O
Q TMU26-640 lbs.
VERTICALLY TO TWO HORIZONTALLY WHERE ELEVATIONS CHANGE. NOTED. POTENTIAL PROBLEMS AND HAZARDS ARE ADDRESSED AND REMEDIES ARE NOTED ON THE Blockina to Rafter(Toe-Nall) (3)8d Common Each End W" UPLIFT W V!)
g.WALL FORMS TO REMAIN IN PLACE IN PLACE 3 DAYS MINIMUM. PLAN. — 4.4
—
h.CURE AND SEAL ALL SLABS ON GRADE WITH 2 COATS HORN CLEAR SEAL OR EQUAL. Rim Board to Rafter End-Nail 2 16d Common Each End 212 — — FOR
� 8/12 p �„) o
i.CONCRETE CONTRACTOR SHALL PROVIDE ADEQUATE BRACING FOR ALL WALLS AS NOT ALL EXISTING CONDITIONS OF A BUILDING ARE EASILY ACCESSIBLE FOR INSPECTION BY THE WALL FRAMING — — H
REQUIRED TO RESIST WIND AND CONSTRUCTION LOADS. — — o REQUIRED @ W
ENGINEER. THEREFORE ENGINEER'S LOOK FOR CLUES FOR EXAMPLE:CRACKS DIFFERENTIAL o o
j. PROVIDE SAWED OR KEYED AND FORMED CONTROL JOINTS FOR SLABS AND WALKS SETTLEMENT CRUMBLING ETC... SUGGEST THAT THE EXISTING FOUNDATION MAY BE FAILING OR 16d 24"O,C. Per Foot ° CATHEDRAL CEILINGS
ON GRADE,AT EVES I MAXIMUM IN BOTH DIRECTIONS.REQUIRED
SETTLING OVER TIME. THE FOUNDATION MAY NEED TO BE REPAIRED, REDONE OR REINFORCED,WHICH To Plate to To plate Face Nail 0 0 w C)
_ IN ADDITION TO RIDGE ^
k.PROVIDE SLEEVES IN FOUNDATION WALLS AS REQUIRED FOR ELECTRIC,PLUMBING WILL BE SHOWN ON THE DRAWINGS. THIS 1S ONE OF MANY OF THE ENGINEER'S ROLES IN A PROJECT. TYPICAL S A6 UPLIFT 2" i1v12
MECHANICAL, ETC.COORDINATE WITH OTHI=R CONTRACTORS, DRAWINGS,AGENCIES, o Plates at intersections Face-N it 2 16d Common Each End � H o o STRAPPING
ETC. CONNECTION INSTALLATION ° o O a
I.CONCRETE FOUNDATION WALLS TO BE CAST MONOLITHIC.NO HORIZONTAL JOINTS THIS ENGINEER HAS INSPECTED THE EXISTING STRUCTURE AND FINDS IT TO BE STRUCTURALLY SOUND Stud to Stud Face-Nail 16d 16"O.C. Each End I I o
SHALL BE PLACED IN WALLS. AS FAR AS THE PARAMETERS OF THIS PROJECT. EVERY PRECAUTION HAS BEEN TAKEN TO INSURE ° m w
m.ALL EXPOSED CONCRETE SLABS TO RECEIVE ENGINEERURAL FINIISH AND THAT THIS STRUCTURE IS SAKE. IF A CONDITION IS DISCOVERED DURING DEMOLITION,CONSTRUCTION Header to Hea er Face-Nail 16d Common 146"o.c.along edges 2 °
SCORING AS PER PLANS AND SPECIFICATIONS. W INSPECTION BY A BUILDING INSPECTOR THIS ENGINEER SHOULD BE NOTIFIED IMMEDIATELY IN To of Bottom Plate to Stud End-Nail 2 16d Common Per Stud /� 4 a W a
n. NO CONCRETE OR MASONRY SHALL BE PERFORMED IN TEMPERATURES 40 DEGREES WRITING SO THE CONDITION OR CONDITIONS CAN BE RECTIFIED. HURRICANE STRAP DETAIL CROSS-SECTION
F.OR LESS. NO CONCRETE SHALL 8E CAST F FROZEN SURFACES:. Bottom Plate to Floor Joist, Band Joist, End RT30F PAL) °
16d Common v-s"O.C.Face Nail tOd NgILSALLHOLES
o.NO ADDITIVES SHALL BE PERMITTED WITHOUT WRITTEN PERMISSION FROM ENGINEER. Josit or Blocking(End-Nail) -995 IDS. UPLIFT ° a
p. ALL FOOTINGS TO BE 8"OR 6" PROJECTION ON EACH SIDE OF FOUNDATION WALL PLUMBING NOTES
MIN. (2)#4 REBARS CONTINUOUS,UNLESS OTHERWISE NOTED(SEIE PLANS). a. PLUMBING TO CONFIRM TO STATE AND LOCAL CODES. Double Top Plate Splice(Face Haile) (6)16d Ea:h Side of SPlice R310 ESCAPE/RESCUE OPENINGS RC LS268&TMU26 ° W
q. PROVIDE MINIMUM 2"x4" KEY BETWEEN FOOTINGS AND FOUNDATION WALL. b. PROVIDE SHUT OFF VALVES ON ALL SUPPLY LINES AT ALL FIXTURES, N TYPICAL LIGHT SLOPE HANGER MM--��--••11
r.CRAWL SPACE VENTS,IN ACCORDANCE w,/R408 ARE TO BE LOCATED WITHIN T-O" c. INSULATE ALL SUPPLY LINES, FOR NAIL NG3 3B "
OF EACH CORNER OF THE BUILDING. d. PROVIDE FROST PROOF HOSE BIBS AS PER PLAN MINIMUM 2 PER NEW RESIDENCE. FLOOR FRAMING a. MINIMUM 34'cLEAR INSTALLATION MI 16 0IZ .�
s.ALL FOUNDATION WALLS AT BASEMENTS TO RECEIVE BITUMINOUS WATERPROOFING. e.ALL FIXTURES TO BE AMERICAN STANDARD, KOHLER OR APPROVED EQUAL, ° OPERABLE AREA MINIMUM
SIZE OF MANGER DETERMINED BY SIZE OF RAFIfER
FURNISHED&INSTALLED BY CONTRACTOR. a 5.7 SQ. FT. (SEE MI"'MUM
CARPENTRY NOTES EXCEPTION)
f.PIPING PENETRATIONS THROUGH FIRE-RATED WALL OR FLOOR ASSEMBLIES ARE TO Joist to Sill T Plate or Girder Fa a-Nall 3 8d Common Per Joist a C) F-•-1 I�
b. MINIMUM OPENING TYPICAL UPLIFT CONNECTION a. ALL WOOD SILLS, BLOCKING,HAILERS,ET(:.IN CONTACT WITH MASONRY,CONCRETE OR COMPLY WI P2603. >_ a
,. HEIGHT 24' / O
SOIL TO BE ACQ(TREATED). g. WATER&DRAINAGE PLUMBING IS TO BE INSTALLED IN ACCORDANCE w/SECT. Bri in to oist(Toe-Nail) 2 8d Common Each End ° / H
o c. MINIMUM OPENING (FOR OPENINGS) x
b. PROVIDE ALUM.TERMITE SHIELD&SILL SEALER AROUND ENTIRE(PERIMETER. P2603.WOOD FRAME DRILLING&NOTCHING ARE TO BE IN ACCORDANCE w/ O WIDTH 20" / a
c.ALL NAILS,BOLTS,JOISTS HANGERS&FRAMING CONNECTORS TO BE HOT-DIPPED P2603.2. PIPE PROTECTION AGAINST PHYSICAL DAMAGE&CORROSION IS TO BE IS Blocking to Joi t(Toe-Nail 2 8d Common Each End TYPICAL RT16T o / INSTALLATION 24
GALVANIZED. TO BE IN ACCORDANCE w/P2603.2.1 &P2603.3.SEE P2603.4&P2603.5 FOR PIPES d. MAXIMUM SILL F-�
OPENABLE (9 1 6 O/C
Each Block TRUSS/RAFTER TO DOUBLE o HEIGHT OF 44" AReA AREA
�� GO O
d.ALL JOISTS, RAFTERS, HEADERS&GIRDER:; SHALL BE DOUG FIR f"b 850 PSI MIN. IN FIRE RATED ASSEMBLIES AND THROUGH FOOTINGS/FOUNDATION WALLS. Blockin to Sill or To Plate(Toe-Nail 3 16d Common O � AREA /
e. MUST BE ` / TYPICAL LSTA24 W
STUDS TO BE MIN. HEM FIR f b 850 PSI. h.PIPE PENETRATIONS THROUGH FOUNDATION WALLS ARE TO BE COVERED w/A PLATE INSTALLATION @ 16 0% O /
Ledger Strip to Beam Face-Nail 3 16d Common Each Joist OPERABLE
e.ALL SHEATHING SHALL BE 112" DOUGLAS FIR EXTERIOR GRADE PLYWOOD,NAILED 6d SLEEVE 2 PIPE SIZES GREATER THAN THE PIPE PASSING THROUGH IT IN Z LSTA24-980 lbs.UPLIFT 20 GA. Q
@ 6"O.C. 2 INTERIOR& INTERMEDIATE BLOCKING POINTS.COVERED WITH 15 LB. ACCORDANCE w/P2603.4. WITHOUT KEYS OR MwsIM M 'MINIMUM t t/a"xza^
BUILDING PAPER OR CELOTEX INFILTRATION BARRIER PROPERLY TAPED&SEALED. i. PIPE SUPPORTS ARE TO COMPLY w/SECT.P2605.TABLE P2605.1 APPLIES,EXCEPT Joist to Led er to Beam Toe-Nail (3)8d Common Per Joist GIRDER TO CONCRETE PIER DETAIL TOOLS i
f.ALL SUB FLOORS TO BE 3/4" PLYWOOD NAILED WITH TWIST NAILS @ 6"O.C. LEAD PIPE IS NOT TO BE USED. PIPE MATERIALS ARE TO COMPLY w/SECT. P2609. �,4_71 CRIPPLE STUD
ALL WALL CORNERS TO BE MIN. 3 STUDS(JAILED 16d- 12'O.C. WHERE THE VOLUMES OF ROOMS AND SPACES ARE COMBINED FOR THE PURPOSE OF Band Joist to Joist End-Nail 3 16d Common Per Joist MINIMUM SIZE WINDOW Z s FOR 24 CLEAR
WINDOW
g• �• FOR 20"CLEAR HEIGHT o wa� FOR 24"CLEAR HEIGHT STRAP REFERENCE 3.36
h. HEADERS,TRIMMERS&JOISTS UNDER PARTITIONS TO BE DOUBLED BLOCK BETWEEN PROVIDING INDOOR COMBUSTION AIR,THERE SHALL BE AT LEAST TWO OPENINGS and Joist to ill or To Plate(Toe-Nail 2 16d Common Per Foot ANCHOR BOLT DETAIL �o x FOR NAILING
JOISTS UNDER PARTITIONS. BLOCK STUD WALLS @ 1/2 STORY HEIIGHTS&AT PROVIDED,ONE WITHIN 1 FOOT OF THE CEILING OF THE ROOM AND ONE WITHIN 1 FOOT TYPICAL UPHD8 INSTALLATION kw
UNSUPPORTED EDGES OF PLYWOOD. OF THE FLOOR FOR COMBINED USE OF INDOOR AND OUTDOOR AIR. SIZE OF VENTS Wood structural panels, subfoor, roof and interior wall sheathing to FLOOR �HEAJER
I.ALL CAP PLATES TO BE DOUBLED&NAILED WITH 16d @ 12"OC LAP CAP PLATES AT TO BE DETERMINED BY MANUFACTURERS SPECIFICATIONS. ANCHOR BOLT-TO-PLATE UPLIF CONNECTION IS REQ'D.@ EA.
framing and particleboard wall sheathing to framing. 4 END OF HEADER&@ BOTTOM OF
CORNER. -TO-STUD CONNECTION HEADER STUDS,IN ADDITION TO
j.HEADERS OVER DOORS AND WINDOWS UP TO 3'-0" WIDE TO BE (2)2x6 FOR OPENINGS See Table R602.3(3) for wood structural panel exterio;r sheathing CONNECTORS @WALL STUDS&
3'-0"TO 5'-0" USE (2)2x8,UNLESS OTHERWISE NOTED. to wall framing
SHEAR WALLS ONLY THE CONSTRUCTION TYPE DESIGNATION SHALL BE "I", "II", @ TOP&BOTTOM OF CRIPPLES
(SLAB ON GRADE,6TC.) "III", "IV", OR"V" TO INDICATES THE CONSTRUCTION
k. FOR HEADERS OVER 5'-0" LONG USE DOUBLE JACK STUDS. —..- ....-----_ _.._ ..... ... ......-_- __-_ �__._..._.____-._._.____..___.__._......_--_. ...__._._.____.------_—.__.____...__.___..._.._....___.___________..._-_-_.___.._.___.__.__.__.._..-_.
Table R602.3 3 Ede Intermediate UPHD8-3,300Ibs.UPLIFT
I.MIN. BEARING FOR JOISTS, BEAMS&STUDS TO BE 3 1/2". I_._.._. ._.. _.._______......__...._.._.._...__ ._. . .. . . .. _( )___.__....._._...._....._.,_._.________._._,..___..._ _ _._..____.. ____....... g s SCREWS CLASSIFICATION OF THE STRUCTURE UNDER SECTION 602
m. PROVIDE SOLID BRIDGING MAX. 8'-0"O.C.IN ALL FLOOR CONSTRUCTION. Requirements for Wood Structural Panel _. .__.__ _._....___..___.._____._.__.._.____..__.._._._-.______: 3/8"-1/2" moron 6" c 12"O C F C WOOD SC OF THE BCNYS FLOOR TO FLOOR CONNECTION
„ rod CO C, FOR CORNERS&
n. PROVIDE COLLAR BEAMS AT RAFTERS AS PER STATE&LOCAL CODES. (16 o/c @ 8d Common
�_... .. __.._.._._ _._. . __ ____________..___._.._..__.________ Wall Sheathing used to Resist Wind
' '.__._...- _,...._.__..-----___..___..__.- _----.___._.____._..._-._ OPENINGS 6-0" GREATER
4'-5"ABOVE ATTIC FLOOR) OR 1/3RD WAY DOWN FROM RIDGE .___ .. _..... .. .......... ______.__..___.__.._.._.. ..-_-�__-___.._.____ _. TYP. CONNECTION FOR TWO Z
I 19/32"-1"
o.ROOF FRAMING IS DESIGNED IN ACCORDANCE w/THE PROVISIONS;OF CH.3 OF THE Pressures _.___..___....._. _ ._..._..__.__.__..____._._._....._.._ _._..____.__...._._. 6d Common G"o.c. 12"o.c. O
---- STORY APPLICATIONS F-•
2018 W.F.C.M. i i Minimum Nominal I /a^%%C ANCHOR BOLT@36"OC
PARALLAM MICROLLAM OR WOOD STRUCTURAL MEMBERS TO BE AS MANUFACTURED _ A i 1 1/8"-1 1/4" 10d Comm n 6"o.c. 12"O.C.. . REFLECT( MINIMUM SHEAR WALL SEGMENT SIZE
P. I Wood Maximum I VE WHITE ASPECT RATIO:H/L<3T -
BY TJI CORP.OR APPROVED EQUAL ` Other wall sheathing
MATERIAL FOR STRUCTURAL MEMBERS IS TO BE IDENTIFIED IN ACCORDANCE W/R502.1 Structural ! Panel Wall Stud i 9 WALL HT.(H) SEGMENT WIDTH(W) W
q' 1/2" Structural Cellusic Fiberboard e'•r' 2'-a^
PLATES 1 1/2"Gaiv Roofing REFLECTIVE RED
MATERIAL FOR LOAD BRG. STUDS, ,AND HEADERS ARE TO BE IDENTIFIED IN 3 Panel Span Thickness Spacing ! 3"c.c. 6"o.c. � 9'-1^
ACCORDANCE w/R602.1. (( thing Nail FOUNDATION PANTONE #187 ,o , 3 0
Minimum Nail Rating (Inches)_; (inches) f Panel Nail Spacing Ultimate Design Wind Speed m Shea s
r. STRUCTURAL FLOOR MEMBERS ARE NOT TO BE CUT, BORED OR NOTCHED IN EXCESS -- - --- - - p _._. p - 2" Structural Cellusic Fiberboard 3/4"Galy Roofing STUD TO NDATION CONNECTION
___.. _..----. ___.._.__g_ __._..__. exposure category ail 3"o.c. 6"a.c. "
OF THE LIMITATIONS SPECIFIED IN FIG. R502.8.CUTS, NOTCHES AND HOLES BORED W ._j_..._.--__.._______..____..' ___._.-_. _ _ g 1 Wind e p g ry _ __ _ Sheathing
ENGINEERED WOOD PRODUCTS ARE NOT PERMITTED UNLESS THE EFFECTS OF SUCH Edges Field I SIMPSON MST27 20 GA.METAL STRAP, FJ DESIGNATION FOR STRUCTURAL COMPONENTS
1/2" Gypsum Wallboard 1 114 Screws 7"O.C. 7"o.c. 12"MIN.ON STUD SURFACE t TYPICAL UPHD8 INSTALLATION
PENETRATIONS ARE SPECIFICALLY CONSIDERED IN THE DESIGN OF THE MEMBER,IN Size Penetration In B C D ! ' THAT ARE OF TRUSS TYPE CONSTRUCTION OWN W/ 5/8 READED ROD( ) ' (Inches o.c.) (Inches D.C.) HOLD °I�H o 3 N
ACCORDANCE W/R502.8.2. STUD DRILLING&NOTCHING ARE ALSOI TO COMPLY w/ - ! TYPICAL LSTA36 N II O
R602.6. (SEE DETAIL) 6d Common; 1.5 24/0 3/8 16 6 12 ! 140 115 I 110 ! 1 516 Screws 7 o.c. 7"o.c.
-._`__.�. __..__ _ _.___.. _._ ___. ..__.___ ..__._:_____ __ . . . GypsumWaliboard
s. IN ACCORDANCE w/SECTION R312.1.3,REQUIRED GUARDS FOR HANDRAILS ARE TO 8d Common 1.75 ; 24/16 I 7/16 1 16 6 1 12 170 140 135 (OR EQUIVALENT) FLOORINCLUDING W
_. -. .._. . :.__._. . _._ __.. EQUIVA
L I I N
I 24 j 6 12 _140 I_ 115 I 00 structural panels combination subfloolr REFERENCE3.36 11 "F FRAMING,AIN '
HAVE GAPS THAT DO NOT ALLOW PASSAGE:OF A 4"ra SPHERE ? ; I 110 ;
W d GIRDERS A BEAMS NOTE _ �
t.STAIR TREADS SHALL BE 1 1/4"'THICK CLEAR OAK,UNLESS NOTED. ------ -- _ _.____� _ __ . _.._.._.._.._�__. __ ___ �_ __L______ FORNAIUNG____ _. .__ ....____ ._._ _ ... 1/Z AND B MAYBE N �+ W �,; J
f REQUIRED
u. INTERIOR TRIM SHALL BE CLEAR MATERIAL UNLESS OTHERWISE NOTED. 3/4"or Less 6d Common 6"o.c. 12"O.C. WRAP&NAIL STRAP AROUND STROKE t, „— ROOF NG FOR SHEAR O � ¢ � �
V.WALL&CEILING FINISHES ARE TO HAVE A FLAME SPREAD CLASSIFICATION NOT SILL @16"OC ON EACH STUD 6" DIAMETER 3 Z
GREATER THAN 200 IN ACCORDANCE w/R302.9.4,&A SMOKE DEVELOPED INDEX TABLE R403.1 MINIMUM WIDTH OF CONCRETE OR MASONRY FOOTINGS Qnches)a 7/6"-1" 6"o.e. 12"o.e. L L ItFBn z A A Q
8d Common 3/8"%%C ANCHOR BOLT@36"OC -�
NOT GREATER THAN 450, IN ACCORDANCE vv/R302.9.4.TESTING(METHODS MUST TRUSS SIGN NOTE:INSTALL TRUSS SIGN AT LOCATION OF INCOMING ELECTRIC SERVICE.CONTRACTOR TO FURNISH AND INSTALL Qa
COMPLY w/R302.9.3 1 116 -1 1/44 10d Common 6"O.C. 12"O.C. LSTA36-1,305 Ibs.UPLIFT 18 GA.1 PROFESSIONALLY.FABRICATE AS DETAILED IN DWG. w U Q 04
Q U
W.
ALL CLOSET SHELVES TO BE CLEAR PINE UNLESS OTHERWISE N07ED. LOAD-BEARING VALUE OF SOIL,(psf) 1/4"x36" � TRUSS SIGNAGE REQ IF ENGINEERED WOOD ON PLANS
x. PROVIDE 1 " WOOD CLOTHES ROD IN ALL CLOSETS. 1,soo 2,000 3,000 e4,000 For wood structural panel roof sheathing attached to gable end r000-framing and to FLOOR TO FLOOR CONNECTION SCALE:
Y.CERAMIC TILE SURFACES&INSTALLATION ARE TO COMPLY w/R7102.4,OTHER Convetionci light-frame construction intermediate supports within 48 inches of roof edges and ridges,mails shall be spaced 1/4" = 1
1-story 12 12 12 12 REQUIRED FOR UPLIFT
FINISHES TO COMPLY w/R702.5,& R702.6. ry at 6 inches on center where the ultimate design wind speed is less than 130 mph and
Z.ANY CHANGES TO THE STRUCTURE SHOULD BE BROUGHT TO THE,ATTENTION OF THE 2-story 15 12 12 12 OPTIONAL NAILS END LENGTH N
ENGINEER BEFORE CHANGES ARE MADE TO THE STRUCTURE ON SITE. 3-:Story 23 17 12 12 shall be spaced 4 inces on center where the ultimate design wind speed is 130 mph or (WOOD SHRINKAGE m 12" YPICAL �� NE y
greater but less than 140 mph MAY OCCUR AND
CAUSESTRAPTO
4-inch brick veneer over light frame or 8-Inch hollow concrete masonry BUCKLE OUTWARD) m * " ��l
ROOFING /SIDING NOTES 1-story 12 12 12 12
2-story 21 16 12 12 RAFTER TO DOUBLE TOP PLATE DETAIL TYPICAL SIFUD PLATE TIE SERIES - SP4
a. ROOF COVERING MATERIALS ARE TO COMPLY w/SECTIONS R902„ INSTALLAT-ION @ 16'' O.C. `�R904, &R905 AND 3-story 32 24 16 12 FLOOR TO FLOOR CONNECTION t' cu
ARE TO BE IDENTIFIED IN ACCORDANCE w/R904.4.ROOF DRAINS ARE TO BE PROP
INSTALLED IN ACCORDANCE w/R903.4.DRAWINGS AND DETAILS TO BE SUBMITTED. 8-inch solid or fully grouted masonry FOR NAILING (CANTILEVER CONDITIONS) CLEARS Nt� 77006 �
FASTENERS:2 t OdX1 1/2 y0
DOUBLE LVL
b.ASPHALT SHINGLE UNDER-LAYMENT IS TO COMPLY w/SECTION Rt905.2.3. SELF SEAL 1-story 16 12 12 12 �O�ESSIONA`,
STRIPS AND FASTENERS ARE TO COMPLY wi R905.2.4& R905.2.5..DETAILS OF 2-story 23 21 14 12 RAFTERS/TRUSS INSTALLATION @ 16"O/C TYPICAL LSTA
ASPHALT SHINGLE ROOFING INSTALLATION ARE TO BE SUBMITTED..FOR ROOF SLOPES 3-story 42 32 21 16 FASTENERS:10-10dX1 1/2 T/0 EXIST 2X4 STUD WALL @16"o.c. Z LSTA24-980 Ibs.UPLI
TYPICAL KST237 DWG. NAME:
OF 4/12, DOUBLE UNDER-LAYMENT IS REQ'D. IN ACCORDANCE w/ R905.2.7.THE REQ'D PLATES I'.I 3/9/16„ g 20GA.1 1/�"xza"
UNDER-LAYMENT IS TO CONFORM w/ASTMC)226, D 1970,D4869, AND D6757,AND IF LSTA24-980 lbs.UPLIFT 20 GA. DETAILS
For V:1 inch=25.4 mm,1 pound per square foot o 0.0479 kPa. 1 1/4"x24" / m
APPLICABLE,TYPE CLASSIFICATION INDICATED IN ACCORDANCE WITABLE R905.1.1(1) DOUBLE EXISTING 2X4 SILL END LENGTH
C. FOR ROOF SLOPES,ICE PROTECTION THAT CONSISTS OF AT LEAST 2 LAYERS OF TOP PLATE PLATE PROVIDE BLOCKING 1"MIN. 4), 12"7 YPICAL
a.Where minimum footing width is 12 inches,use of a single wythe of solid or & NOTES
UNDER-LAYMENT CEMENTED TOGETHER, OR A SELF ADHESIVE POLIYMER MODIFIED fully grouted 12-inch nominal concrete masonry units is permitted. z PROPOSED 2X4 DOUBLE TOP
BITUMEN SHEET, IS TO BE USED&IS TO EXTEND FROM THE EAVES EDGE TO 24 MIN. v PLATE FLOOR-TO-FLOOR °
INSIDE THE EXTERIOR WALL LINE OF THE BUILDING IN ACCORDANCE w/R905.2.7.& N a REFERENCE3.36 REFERENCE3.313 DWG. NO.:
R905.1.2. F_ FOR NAILING n
d.FLASHING MATERIALS ARE TO BE CORROSION-RESISTANT AND INSTALLED IN 2"MIN. INSTALLATION @ 16 O/C FOR NAILING
ACCORDANCE w/R703.8,R903.2,&R905.2.8' 2X4 STUD WALL @ 16" \
e. HOUSE WRAP MATERIAL OR BUILDING FELT& IT'S INSTALLATION ARE TO COMPLY w/ O.C. STRAP @
R703.2 V / PROP 2X4 STUD WALL @16"O.C. EACH STUD
f.WEATHER RESISTANT SIDING ATTACHMENT AND MIN.THICKNESS,ARE TO COMPLY w/ TYPICAL H16 -1470 lbs. UPLIFT 6-1001 1/2" _
(0.148"x11/2") �', WALL TO CRIPPLE WALL CONNECTION
R703.3.2. TRUSS/RAFTER TO DOUBLE _
PLATE INSTALLATION PAGE 2 OF 2