Loading...
HomeMy WebLinkAbout52239-Z �o��pF SOpryo`o Town of Southold * * P.O. Box 1179 • Ao4 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46812 Date: 01/23/2026 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1170 Leslie Rd CutchoQue, NY 11935 Sec/Block/Lot: 97.-9-1 Conforms substantially,to the Application for Building Permit heretofore,filed in this office dated: 07/29/2025 Pursuant to which Building Permit No. 52239 and dated: 09/08/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof-mounted solar panels to an existing single-family dwelling as applied for. The certificate is issued to: Matthew Lindsay, Christina Lindsay Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 112977 9/18/2025 PLUMBERS CERTIFICATION: AuthorVed Signat e of Sao lyolo TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52239 Date: 09/08/2025 Permission is hereby granted to: Matthew R Lindsay 1170 Leslie Rd Cutchogue, NY 11935 To: install roof-mounted solar panels to an existing single-family dwelling as applied for. Premises Located at: 1170 Leslie Rd, Cutchogue, NY 11935 SCTM#97.-9-1 Pursuant to application dated 07/29/2025 and approved by the Building Inspector. To expire on 09/08/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 CO-RESIDENTIAL $100.00 Total S200.00 Building Inspector NASSAU ELECTRICAL SUFFOLK INSPECTORS 159 Route 25A, Building 1 Suite B Miller Place,NY 11764 Telephone:631 495 8136 • Fax:631 509 4538 • E-Mail: Requests@SuffolkBEI.com CERTIFICATE OF ELECTRICAL COMPLIANCE Applicant: Harvest Power LLC Certificate No.: 112977 Rough In Inspection Date: Final Inspection Date: Sep 18,2025 Application No.: Building Permit No.: 52239 County Tax Map No.: 097.00 09.00 001.000 This Certificate of Electrical Compliance is limited to the inspection and compliance of electrical equipment and/or work described below,installed on behalf of the applicant named above,located at the premise of and not after the final inspection date above: Owner: Christina Lindsay Site Location: 1170 Leslie Road,Cutchogue,NY 11935 Owner's Address(if different): Residential 19 Indoor ❑Basement ❑Service ❑Shed ❑Commercial 0 Outdoor ❑First Floor ❑Pool ❑Hottub O New 0 Renovation 0 Second Floor OAttic ❑Garage ❑Addition ❑Survey ®PV Solar 0 Generator ❑Conversion - ---------------- 0 Signs ❑Battery Storage 0 Safety Inspection Other:: INVENTORY Single Phase Heat Duplex Recpt 0 Ceiling Fixture F Dual Func Breaker Three Phase Hot Water GFCI Recpt 0 Wall Fixture Smoke 0 Main Panel AC Cond 0 Single Recpt Recessed Fixture CO Detect Sub Panel AC Blower Range Recpt LED Lighting Smoke CO Combo Transformer F1 Appliance Ckt Dryer Recpt Emergency 0 Time Clock 0 Disconnect 0 Switches 0 Twist Lock Exit Fixtures 0 Pumps 0 GFCI Breaker Heat Pump Electric Heat Pool Luminaire Exhaust Fan Other Equipment:System Size:5.98 kW Qty:13 Desc:REC REC460AA Qty:13 Desc:Enphase IQ7X-96-2-US The electrical work and/or equipment described above were inspected and was found to be in compliance with local, state and national electrical code requirements and this office. Applicant: Harvest Power LLC License No.: ME-68518 Date Printed: Sep 18,2025 �7r-� ),) E C E Inspected By:Joe Coppola 0 CT 1 0 2025 Signature: ��iJJY.'//11YYll OF SOUTyOIo � 1 # * TOWN OF SOUTHOLD BUILDING DEPT. o ,�,� 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ AeIFINAL �l [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: Ok- C- DATE - INSPECTOR Graham Associates 256 Orinco Dr, Brightwaters, NY 11718 Building Consultants & Expeditors (631) 665-9619 Fax (631) 969-0115 September 17, 2025 Town of Southold Building Department Post Installation Certification Lindsay Residence — 1170 Leslie Road, Cutchogue, NY 11935 Permit # 52239 Installation Date: 9/11/2025 Inspection Date: 9/15/2025 To Whom It May Concern, The roof mounted photovoltaic system at the above referenced residence has been installed properly in accordance with the approved plans and is certified by Michael K. Dunn, RA, to be in compliance with the minimum requirements of the 2020 New York State Residential Building Code; Town Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020 National Electric Code including ASCE7-16. If you have any further questions, do not hesitate to call. ARO IJ °.o- 0 CT 1 0 2025 BO Mi&hie-f bunn, RA B;Alding D-pars-petit FIELD INSPECTION REPORT DATE COMMENTS �o FOUNDATION (1ST) — ------- ----------------------------------- — — FOUNDATION (2ND) cn ^' O 0 ROUGH FRAMING& PLUMBING � r r INSULATION PER N.Y. STATE ENERGY CODE _— FINAL ADDITIONAL COMMENTS �i oS 4-41 Cam' �- P2,10- c- cl — o ►o O -- r ro r 44 \11FF0(KcDQ TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 ��y a Telephone (631) 765-1802 Fax(631) 765-9502 hiMs://Www.souiholdtownny.gov Date Received APPLICATION FOR BUILDING PERMIT no For Office Use Only PERMIT NO. Building Inspector: U JUL 2 g 2025 6 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Building®ep,,,1gmont Owner's Authorization form(Page 2)shall be completed. Town of Southoid Date: 7/15/2025 OWNER(S)OF PROPERTY: Name:Chj-;bti^o, Lindsay SCYM#1000- 097.00 - 09.00 - 00 1.000 Project Address: 1170 Leslie Road, Cutchogue, NY 11935 Phone#: (516) 356-1427 Email: clindsay@aol.com Mailing Address: 1170 Leslie Road, Cutchogue, NY 11935 CONTACT PERSON: Name: Michael Calise Mailing Address: 2941 Sunrise Hwy, Islip Terrace, NY 11752 Phone#: (631) 647-3402 Email: hppermitting@harvestpower..net DESIGN PROFESSIONAL INFORMATION: Name: Michael Dunn, R.A. Mailing Address: 256 Orinoco Dr, Brihtwaters, NY 11718 Phone#: (631) 665-9619 Email: Glenn@grahamassociates .com CONTRACTOR INFORMATION: Name: Harvest Power LLC Mailing Address: 2941 Sunrise Hwy, Islip Terrace, NY 11752 Phone#: (631) 647-3402 Email: hppermitting@harvestpower..net DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition❑✓ Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ 22,080.00 Will the lot be re-graded? ❑Yes MNo Will excess fill be removed from premises? ❑Yes ❑No 1 PROPERTY INFORMATION Existing use of property: Residence Intended use of property: (no change) Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ®No IF YES, PROVIDE A COPY. ®Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law. Application Submitted By( 'n name): MIC ael Calise Authorized Agent ElOwner Signature of Applicant: � Date: STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Michael Calise being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent of Harvest Power LLC (Contractor,Agent, Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this Clay of �1[DL y .20 � -.- Notary*elbfia C.HAPSHE Notary Public,State of New York No.01HA4928056 Qualified in Suffolk Co u ty PROPERTY OWNER AUTHORIZATION Term expires-02 ' r (Where the applicant' is not the owner 1, Christina Lindsay . residing at 1170 Leslie Road Cutchogue, NY, 11935 do hereby authorize Michael Calise to apply on my behalf to the Town of Southold Building Department for approval as described herein. ( < <— 7/16/2025 Owner's Signature Date Christina Lindsay Print Owner's Name 2 i `i I Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) i I, Christina Lindsay residing at 1170 Leslie Road (Print property owner's name) (Mailing Address)' Custogue, NY, 11935 do hereby authorize Michael Calise (Agent) Harvest Power LLC to apply on my behalf to the Southold Building Department. �,w,a—'F -�- ,•� 7/16/2025 (Owner's Sigahirc) (Date) Christina Lindsay (Print Owner's Name) f 1 CONSENT TO INSPECTION i i I f i l Christina Lindsay ,the undersigned, do(es)hereby state: j Owner(s)Name(s) That the undersigned(is) (are)the owner(s)of the premises in the Town of j Southold, located at 1170 Leslie Road, Cutchogue, NY 11935 , which is shown and designated on the Suffolk County Tax Map as District 1000, Section 097.00 , Block 09.00 ,Lot 001.000 That the undersigned(has)(have)filed,or cause to be filed,an application in the Southold Town Building Inspector's Office for the following: SOLAR Installation of a 5.98 kW Solar PV system with ( 13 ) REC460AA Pure-RX Roof mounted panels. i f That the undersigned do(es)hereby give consent to the Building Inspectors of the Town of Southold to enter upon the above described property, including any and all buildings located thereon, to conduct such inspections as they may deem necessary with respect to the aforesaid application, including inspections to determine that said premises comply with all of the laws, ordinances,rules and regulations of the Town of Southold. i j The undersigned, in consenting to such inspections;do(es)so with the knowledge and understanding that any information obtained in the conduct of such inspections may be used in subsequent prosecutions for violations of the laws, ordinances,rules or regulations of the Town of Southold. Dated: 7/16/2025 (Signature) Christina Lindsay (Print Name) (Signature) (Print Name) � � r �S�FfO(�c Ue BUILDING DEPARTMENT-Electrical Inspector �Gy�< TOWN OF SOUTHOLD o Town Hall Annex- 54375 Main Road - PO Box 1179 u' ^ Southold, New York 11971-0959 �apV Telephone (631) 765-1802 - FAX (631) 765-9502 lamesh(a-D-southoldtownny.4ov - seand(aD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 7/16/2025 Company Name: Harvest Power LLC Electrician's Name: Carlo Lanza License No.- ME-68518 Elec. email:hppermitting@harvestpower.net Elec. Phone No: (631) 647-3402 01 request an email copy of Certificate of Compliance Elec. Address.: 2941 Sunrise Highway, Islip Terrace, NY 11752 JOB SITE INFORMATION (All Information Required) Name: Christina Lindsay Address: 170 Leslie Road, Cutchogue, NY 11935 Cross Street: Phone No.: (516) 356-1427 Bldg.Permit#: email: ^5a13(r�Notko7► Corn Tax Map District: 1000 Section:097.00 Block: 09.00 Lot:001.000 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Installation of a 5.98 kW Solar PV system with (13) REC460AA Pure-RX Roof mounted panels. Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑✓ NO -]Rough In ❑ Final Do you need a Temp Certificate?: F&-/] YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information- PAYMENT DUE WITH APPLICATION f HARVESTPoi7>>` n Harvest Power LLC 1 2941 Sunrise Highway, Islip Terrace, NY 11752 1 631-647-3402 1 harvestpower.net September 19, 2025 Solar Permit Closeout - Please see Electrical Certificate and Post Install Letter Town of Southold Permit# 52239 Customer information: Christina Lindsay 1170 Leslie Road Cutchogue, NY 11935 0 CT 1 0 2025 Kind Regards Bulldina Dk-nartment Town of Sc,,Al)nidl Michael Calise Permit Expeditor (631) 647-3402 Mcalise@harvestpower.net Graham Consulting Corp. 256 Orinoco Drive,Suite A Brishtwaters,NY 11718 Planning&Design (631)665-9619 July 23, 2025 Town of Southold Building Department 54375 Rt. 25 Southold, NY 11971 Re: Christina Lindsay Residence 1170 Leslie Road Cutchogue, NY Proposed 5.98 kWDC, 4.10 kWAC PV System To Whom It May Concern, Please be advised that I have analyzed the existing roof structure at the above-mentioned premises and have determined that it is adequate to support the additional load of the solar panels and a 140 mph wind load and 20 psf snow load without overstress, in accordance with the following: The 2020 New York State Uniform Fire Prevention and Residential Building Code; Town of Southold Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020 National Electric Code including ASCE7-16 If you have any further questions, do not hesitate to call. Sin �rql Ll.3314 9rp u: �� ryfly M1 >� r, . 0[= �y APPR VED AS NOTED oA B.p 0 gs� 3 FEE l BY.- NOTIFY BUILDING DEPARTMENT AT 631 765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMg!NG 3. INSULATION 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR ELECTRICAL DESIGN OR CONSTRUCTON ERRORS INSPECTION REQUIRED COMPLY WITH ALL CODES OF NEW YORK STATE &TOWN CODES AS REQUIRED AND CON .ITIONS OF SYE ZBA SN PLANNING BOARD SWI TRUSTEES N Wo OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY PHOTOVOLTAIC ROOF MOUNT SYSTEM 13 MODULES-ROOF MOUNTED - 5.98 kWDC, 4. 10 kWAC I p 1170 LESLIE RD, CUTCHOGUE, NY 11935, USA HARVEST lnw> HARVEST POWER LLC - - — — _ - — — — - 2941 SUNRISE HIGHWAY ISLIP SYSTEM SUMMARY: GOVERNING CODES: SHEET INDEX TERRACE,NY 11752 (N) 13-REC SOLAR REC460AA PURE-RX(460W)MODULES TEL:(801)989 3585 2017 NATIONAL ELECTRICAL CODE PV-0 COVER SHEET J ER,E. bsite:www.harvest r.net (N) 13-ENPHASE IQ7X-96-2-US MICRO-INVERTERS PV-1 SITE PLAN WITH ROOF PLAN v', „ ; (N)JUNCTION BOX 2020 NEW YORK STATE UNIFORM CODE (E)200A MAIN SERVICE PANEL WITH (E)200A MAIN BREAKER 2020 NEW YORK STATE RESIDENTIAL CODE PV-1.1 ENLARGED VIEWJ' ^�� PV-2 ATTACHMENT DETAILS A— PV-3 THREE LINE DIAGRAM t r (N) ENPHASE IQ COMBINER BOX \ PV-4 PLACARD&WARNING LABELS �? �j PV-5 ADDITIONAL NOTES DESIGN CRITERIA: PV-6+ SPEC SHEETS '.. 4` . . 'o ROOF TYPE: -ASPHALT SHINGLE �� ��817 NUMBER OF LAYERS: - 1 OFNE\N O VERSION ROOF CONDITION: GOOD ESCRIPTION DATE REV. ROOF FRAME: -2"X6"RAFTERS @16"O.C. BLDG.PERMIT 07i2212025 0 STORY:- 1 STORY SNOW LOAD : -25 PSF WIND SPEED :-130 MPH WIND EXPOSURE:-D GENERAL NOTES: w 1. INSTALLATION IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. ARRAY LOCATION - PROJECT SITE 2. ENGINEER TO INSPECT PROJECT AFTER INSTALLATION AND CERTIFY COMPLIANCE 3. PROJECT TO BE INSTALLED WITH CODE COMPLIANT Mari( RACKING INSTRUCTIONS FOR UNI-RAC SOLAR MOUNT PROJECT NAME SYSTEM. 4. FOLLOW BALLASTING SCHEDULE ON ROOF PLAN. Q Greenport O 5. HARVEST POWER, LLC.,THE SOLAR INSTALLATION w U) O 0 CONTRACTOR, COMPLIES WITH ALL LICENSING &ALL RELATED REQUIREMENTS OF THE GOVERNING Q uj O O MUNICIPALITIES AND THE LOCAL ELECTRIC UTILITY I L It _ 00 co 00 J H AHJ'S. Z �- O Shen LU 6. THIS PROJECT WILL COMPLY WITH THE CURRENT NEC " _ r- REQUIREMENTS INCLUDING ARTICLE 690 SOLAR SO111�10Id �'�.ISIar J i >_ O (II O PHOTOVOLTAIC PV SYSTEMS. i Q (n Z O a LL. 7. THE ROOF WILL HAVE NO MORE THAN A SINGLE LAYER OF ROOF COVERING IN ADDITION TO THE SOLAR - J LL! 00 } O Peco is . F � F- EQUIPMENT. BAY VIFK U) O O J _ ti - 8. INSTALLATION WILL BE FLUSH-MOUNTED, PARALLEL � ("�e O O � O TO AND NO MORE THAN 6.5"ABOVE ROOF �- _ 9. MAINTAIN A MINIMUM OF 18"CLEARANCE AT RIDGE _ AND AT ONE GABLE EAVE. 1170 Leslie Rd, 10. THIS DESIGN COMPLIES WITH 130 MPH WIND 48 Cutcih0 ue NY U Z) 0- _ REQUIREMENTS OF THE RESIDENTIAL CODE OF N.Y.S s.� l 11935, United States U Q Q AND ASCE 7-16. 11. WHEREVER THE ROOF PLAN DOES NOT COMPLY WITH L NOya( ACCESS AND VENTILATION REQUIREMENTS OF THE Mai&tkk New Suffolk SHEET NAME UNIFORM CODE, HARVEST POWER PROPOSES THAT ALTERNATIVE VENTILATION METHODS WILL BE COVER SHEET EMPLOYED. REVIEW AND APPROVAL SHALL BE AT THE s DISCRETION OF THE MUNICIPALITY IN WHICH THIS _. ,. � ,' SHEET SIZE DOCUMENT HAS BEEN FILED. ANSI B 12. THE DESIGN PLANS COMPLY WITH THE 2020 NEW YORK STATE UNIFORM FIRE PREVENTION AND 11" X 17" RESIDENTIAL BUILDING CODE. 1 AERIAL PHOTO 2 VICINITY MAP SHEET NUMBER PV-0 SCALE: NTS PV-0 SCALE: NTS �r PV_0 ROOF ACCESS AREA: MODULE TYPE, DIMENSIONS & WEIGHT IV \ SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND NUMBER Or MODULES = 13 MODULES A `MODULE TYPE= REC SOLAR REC460AA PURE-RX(460W) MODULES OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND LOCATED AT STRONG POINTS OF - Q-/ '�. �� \ BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT MODULE WEIGHT=50 LBS/22.7 KG. MODULE DIMENSIONS= 68"X 47.4"=22.38 SF QQ/0. %\ CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS. UNIT WEIGHT OF ARRAY=2.23 PSF - \ J `� HARVESTS^' HARVEST POWER LLC `\ \ Ei S® 2941 SUNRISE TERRACE,HIGHWAYN11 � 1SLIP �^ � \` �� NA #n TEwww.harvest35wernet CVl . 8'' / \ ^' `� (E) FENCE tz A~ n ` B y z a f � -+ \ (E) SHED 7� D :.._ _\ .: `v o`, '9817 VERSION `����� �� �.- ♦ A\ DESCRIPTION DATE REV. C A^O `��_.Y��.{` Y�') / (cti,�'� ♦ / \�Q� BLDG.PERMIT 07/22/2025 0 SEE ENLARGED VIEW ON PV-1.1 . ` PROJECT NAME (E) GATE `` 8b' %� < Q O Q 0 �( 0 O O z r' O J �� S�0, w (n LLJ 0 CD C �� (c r ( � > SHEET NAME SITE PLAN WITH (E)TREE (TYP.) �� , "� �c �� �� ��j�. ROOF PLAN r `\ (�< ( 1 �� � � r SHEET SIZE %C]�r � (� �(� �) 1 ; ANSI B 11" X 17" \ SITE PLAN WITH ROOF PLAN � �v J> 14 SHEET NUMBER 1 SCALE: 1/32"=T-0" \ i�V PV-1 V Q� MO PE, DIMENSIONS & WEIGHT — -�' ' (E) UTILITY METER NUMBER OF MODULES = 13 MODULESMODULE c�o� — TYPE= RE (E)200A MAIN SERVICE PANEL MODULE WEIGHT=0 LBS/22.7 KG.OAA PURE-RX(460W) MODULES gpFFss _ — t / . WITH (E)200A MAIN BREAKER MODULE DIMENSIONS= 68"X 47.4"=22.38 SF (INSIDE) UNIT WEIGHT OF ARRAY=2.23 PSF HARVESTPC. WFP HARVEST POWER LLC 2941 SUNRISE HIGHWAY ISLIP TERRACE,NY 11752 _ ���' - TEL:(801)9893585 _ (N) ENPHASE I �J ���j� sj harvest wernet — _ COMBINER B Ja�s�17 (E) CHIMNEY �Nc-W Y VERSION DESCRIPTION DATE REV. 6LDG.PERMIT 07/22/2025 0 (N) 1" PVC CONDUIT a � � RUN 7/8"ABOVE ROOF (N) JUNCTION BOX PROJECT NAME } 5 O Q o p ♦ 0 rn o J F- o CD (7 � —� z J } O (D O ROOF#1 Q co Z O LL. ��J� ♦ (13) REC460AA PURE-RX (460W) Z J LLj �p RAFTERS=2"X6"@16" O.0 o O Z o� ♦ 129°AZIMUTH, 21°TILT O O 0 P ♦ U Z ♦ (13) ENPHASE IQ7X-96-2-US U Q Q . MICRO-INVERTERS ♦ ♦ SHEET NAME ENLARGED . VIEW SHEET SIZE ANSI B 11 X 171 ENLARGEDVIEW QOOG SHEET NUMBER 1 ■ SCALE: 1/8"= T-0" ��P PV-1 .1 P PV MODULES n HARVEST007 WFP HARVEST POWER LLC 2941 SUNRISE HIGHWAY ISLIP s,. r— - TERRACE,NY 11752 f- C J TEL:(801)989-3585 -�" A. bsite:www.ham wer.net SEE ENLARGED VIEW 16 O E ASPHALT SHINGLE ROOF z�-t .� 02 n GENERAL NOTES: `�1 E't VERSION 1. RAILS TO BE INSTALLED TWO PER PANELS AS SHOWN IN DE IL. DESCRIPTION DATE REV. 2. ALL PENETRATIONS TO BE MADE@ 48"O.C. BLDG.PERMIT 07/22/2025 0 3. BOLTS TOBE INSTALLED INTO RAFTERS. 4. MINIMUM 2.5" PENETRATION INTO WOOD FOR CODE COMPLIANCE. NOTE:- ATTACHMENT DETAIL "ACTUAL ROOF CONDITIONS AND RAFTERS (OR SEAM) LOCATIONS MAY 1 SCALE: NTS VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS." END / MID CLAMP PV MODULES PROJECT NAME Q p O LQ p � � o T� L-FOOT z W o W O J � p Q (n Z p a LL. (E) ASPHALT SHINGLE ROOF Z J W O O Z) CD Z o (N) UNIRAC ROOF/ DECK MEMBRANE p J SM STANDARD RAIL O CD ? O _ 2 0 it 0- (E) 2"X6" RAFTERS @ 16" O.0 2.5" MIN. EMBEDMENT SHEET NAME ATTACHMENT FLASH KIT PRO FLASHING DETAIL SHEET SIZE ANSI B BUILDING STRUCTURE 5/16" STAINLESS STEEL LAG BOLT 11" X 17" WITH SS EPDM BONDED WASHER, DATTACHMENT_ DETAIL ENLARGE VIEW) 2-1/2" MIN. EMBEDMENT. SHEET NUMBER 2 SCALE: NTS PV-2 i (13) REC SOLAR REC460AA PURE-RX(460W) MODULES BILL OF MATERIALS (13) ENPHASE IQ7X-96-2-US MICRO-INVERTERS EQUIPMENT QTY DESCRIPTION (01) BRANCH OF 7 MODULES & SOLAR PV MODULE 13 REC SOLAR REC460AA PURE-RX(460W)MODULES (01)BRANCH OF 6 MODULES CONNECTED IN PARALLEL PER BRANCH MICRO-INVERTER 13 ENPHASE IQ7X-96-2-US MICRO-INVERTERS JUNCTION BOX 1 600V,55A MAX,4 INPUTS,MOUNTED ON ROOF FOR WIRE&CONDUIT TRANSITION SYSTEM SIZE:- 13 x 460W- 5.98 kWDC INTERCONNECTION COMBINER BOX 1 ENPHASE IQ COMBINER BOX HARVEST /o RULE - NEC 705.12 B 2 3 b ` HARVEST POWER LLC 120 13 x 315VA= 4.10 kWAC ° ( )( )( )( ) ,S�E RP-O 2941 SUNRISE HIGHWAY(SLIP TERRACE,NY 11752 UTILITY FEED + SOLAR BACKFEED �?� Oti,.AA I- ,rr TEL:(801)989-3585 200A+ 25A= 225A n� �' site:www.harvest owecnet • 2 �; BUSS RATING x 120% W 200A x 120% = 240A -3 7�A `.4. O; 9g 17 Af— �O VERSION DESCRIPTION DATE REV. BLDG.PERMIT 07/22/2025 0 7 MICRO-INVERTERS IN BRANCH CIRCUIT#1 BI-DIRECTIONAL _._. UTILITY METER _ 1-PHASE,3-W, 120V/24OV,60Hz IF TT (N)ENPHASE COMBINER BOX ~ -� -------- ----------------�--�J -- ----- I L (E)200A MAIN 6 MICRO-INVERTERS IN BRANCH CIRCUIT#2 I SERVICE PANEL j W/(E)200A f2OA MAIN BREAKER • • • (N)JUNCTION BOX (TOP FED) PROJECT NAME (N)25A/2P PV 200AK O�jti Q Lri O --------- ----------------- ------- 0 2 I ^ z rn o L1 L1 IQ W � M W O (13) ENPHASE IQ7X-96-2-US I M' ENVOY V;3/2P J O U) co MICRO-INVERTERS i r----------------- ---------------------I Z c) LL CD L---- --------- -'� -- -------- ------ -- N I I n J w O O TERMINATOR CAP ON LAST CABLE ______________ ___ J ~ CONNECTOR Q-CABLE(TYP) L J i Cn FO (D O O J (3)#6 BLK RED WHT THHN O O O (2)Q-CABLE (4)#10 AWG THWN-2 (1)#6 THHN STRANDED (1) PV 6 BARE CU GND (1)#6 THHN STRANDED GREEN GROUND IN 1"PVC ~———————— GREEN GROUND CONDUIT RUN EXISTING GROUNDING I— Z IN 1"PVC CONDUIT SYSTEM a Q U Q SHEET NAME THREE LINE DIAGRAM SHEET SIZE ANSI B 11" X 17" 1 THREE LINE DIAGRAM SHEET NUMBER SCALE: NTS PV-3 AWARNIN q6-A lk-- AWARNING ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM SOLAR PV SYSTEM EQUIPPED r • , COMBINER PANEL WITH RAPID SHUTDOWN TERMINALS ON LINE AND LOAD DO NOT ADD LOADS HARVEST "'�— SIDES MAY BE ENERGIZED IN HARVEST POWER LLC THE OPEN POSITION LABEL LOCATION: 2941 SUNRISE HIGHWAY ISLIP PHOTOVOLTAIC AC COMBINER(IF TERRACE,NY 11752 APPLICABLE). \t.� �� q TEL:(801)989-35 ite:www.harvest o85 et LABEL LOCATION: G,!e INVERTER(S),AC DISCONNECT(S),AC 3" TURN RAPID SHUTDOWN COMBINER PANEL(IF APPLICABLE). SWITCH TO THE"OFF" SOavParve saic G ^^ POSITION TO SHUT DOWN PV SYSTEM AND REDUCE C/)_; ' —! SHOCK HAZARD IN THE `i.'.,, A •RAPID ARRAY. 0 93 SWITCH 17 R SOLAR P .c"JE�f�r Y � VERSION DESCRIPTION DATE REV. SYSTEMLABEL LOCATION: BLDG.PERMIT 07/22/2025 0 ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE LABEL LOCATION: DISCONNECTING MEANS TO WHICH THE PV SYSTEMS UTILITY SERVICE ENTRANCE/METER,INVERTER/DC ARE CONNECTED. DISCONNECT IF REQUIRED BY LOCAL AHJ,OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. AWARNINQ4 POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS PROJECT NAME OVERCURRENT DEVICE J Q LABEL LOCATION: CD ADJACENT TO PV BREAKER AND ESS OCPD(IF APPLICABLE). — — — Q O O BUILDING SUPPLIED BY UTILITY cn o o GRID AND PHOTOVOLTAIC z =' o (D T SYSTEM � J } o � cn Q cn z o a- L1_ WARNING- • • • z J Lu rn O • • (N)PV MODULES � 0 � C) 0 J O LABEL LOCATION: O O O INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, w AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. C) U z = U Q PHOTOVOLTAIC AC DISCONNECT SHEET NAME OPERATING PLACARD & MAXIMUM AC�MINAL�. ., VOLTAGE:TING AC .. ,� WARNING LABELS SHEET SIZE VAC LABEL LOCATION: AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF (E)UTILITY METER ANSI B (E)MAIN SERVICE PANEL INTERCONNECTION. (INSIDE) 7 (N)COMBINER BOX LABEL LOCATION: SHEET NUMBER POINT OF INTERCONNECTION (PER CODE:NEC690.56(B), NEC705.10,225.37,230.2(E)) PV-4 1 . EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER MANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE BONDED. IF THE EXISTING GROUNDING HARVEST """" ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, HARVEST POWER LLC SUNRISE IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL 2941TERRACE,Y117 ZISLIP TEL:(801)989-3585 GROUNDING ELECTRODE. ,G\\\ ERF website:www.harvesfpower.net 2. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC, ENGRAVED OR ' �' fn cn MACHINE PRINTED IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL y i z ti BE UV RESISTANT IF EXPOSED TO SUNLIGHT. 09 �£ 3. AC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED, "CAUTION AC VERSION CIRCUIT" OR EQUIV. EVERY 5 FT. DESCRIPTION DATE REV. BLDG.PERMIT 07/22/2025 0 4. EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A). 5. CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER VOLTAGE OPERATIONAL RANGE. 6. OUTDOOR EQUIPMENT SHALL BE NEMA-3R RATED OR BETTER. PROJECT NAME 7. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND Q ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. oo 0 Qr 8. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL p C o MEANS DESIGNED AND LISTED FOR SUCH USE, AND FOR ROOF-MOUNTED Z w = � w O SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELP OFF OF THE J J >_ o cn c) CL ROOF SURFACE. NEC 110.2 - 110.4 / 300.4 Q z o Z J ? o } O �- 9. ALL ROOF PENETRATIONS MUST BE FLASHED. SIMPLY CAULKING DOES NOT U) O CD CD SUFFICE. O o O U � z U Q Q SHEET NAME ADDITIONAL NOTES SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-5 HARVEST HARVEST POWER LLC REC 2941 SUNRISE TERRACEHIGHWAY Y ISLIP RE C SOLAR'S MOST TRUSTED 117 TRUSTED SOLAR'S MOST TEL:(801)989-3585 +Y SDATASHEET websitemww.harvestpower net M reinen i,Nr� GENERAL DATA •'" ' Cell Type 88 half-cut bifacial REC hetero unction cells, r.� -- n• � with gaplesstechnology ��V��`p ^ n REF ALPHA Glass 0.13in solxglasswithanti-reflectiveingodancewithEN1215t in accordancewi[hEN12150 � � � -�5` �-A Backsheet Highly resistant polymer(Black) ••• s~j`s�, [� Frame Anodized aluminum(Black) PURE-RX SERIES 4-part 4 bypass diodes, � - � � �• � � �^ i Junction Box y �> IP68rated,inaccordancewithlEC62790 StSubli MC4 PV-KBT4/KST4(12AWG) Connectors in accordance with lEC6285ZIP68 only when connected - 25817 VERSION Cable 12AWGsolarcable.66.9in.•66.9in. ` l,1, TION DATE REV. DATAS H E E T in accordance withEN506 �V 1B ;sf�,.�/ Dimensions 68x47.4z12 in.(22.4 ft°) � G.PERMIT 07/22/2025 0 Weight 50lbs - ,w "ov - BA-,a Origin Made in Singapore y r 0 ELECTRICAL DATA PRODUCT CODE'RECxxxAA Pure-RX CERTIFICATIONS _ Power Output-P_(W) 450 460 470 IEC612152021:IEC61730:2016:UL61730 m Watt Class Sorting-(W) 0/t10 0/*10 0/*10 1S011925-2 Ignitability(EN 13501-1 Class E) IEC 62716 Ammonia Resistance ° Nominal Power Voltage-V_(V) 54.3 54.9 55.4 IEC61701 Salt Mist(SM6) Nominal Power Current-1, (A) B29 8.38 849 IEC61215-2016 Hailstone(35mm) UL61730 FireType2 ^ Open Circuit Voltage-V,x(V) 65.6 65.8 65.9 150 1400 1;1509001;IEC4500 1:IEC62941 Short Circuit Current-Ix(A) &81 8.88 8.95 Power Density(W/ft') 20.1 20.5 21.0 0�E OA ` take0wayun Panel Efficiency(%) 21.6 22.1 22.6 �-- ` r+r..wxerr PROJECT NAME Power Output-P„pa(We) 343 350 358 t- Nominal Power Voltage-V_(V) 51.2 51.7 52.2 'Q'^ CD 0 IIOD RR vJ Z Nominal Power Current-IMPe(A) 6.70 6.77 6.86 C) J Open Circuit Voltage-V (V) 61.8 62.0 62.1a OO Short Circuit Current•Is,(A) 7.11 7.17 723 WARRANTY co - (D _ fia" 9 1^t ray'' .•�• Standard REC ProTrust Q C) J Vale t twdadtestwn*U (STCaVrr m"ts.hidencelOMW/rti'.WWp e77'F(ISC)16asedmaprodxtlmspreatlwCnatokrace11 Va61-IM N ,,Nye -N rt-, warn,omeapera,Bee�era�ep+nor:.rmasnn+ts eradaiaaoow/W.terry�.worse•P(20•Cl•nd:peed33rys(,r�)1•wher. Installed by an REC (•^, sry -i_,ominal I-d-(P_)xsre,o-. �-+ Certified No No Yes Yes z W Q MAXIMUM RATINGS* TEMPERATURE RATINGS' System Size All <25kW 25-500kW J W w ' ''W�. K-�'a� -�' v Product Warranty(yrs) 20 25 25 CD v! O Operational Temperature -40'F-185°F Nommal ModuleOperating Y g Temperature 44'C 2°C Power Warrant rs 25 25 25 r^ Z O LL { • _ _ ' •'rr'� System Voltage 1000V Y(Y ) V J Q �^ d r. �, '� _'��! �► Maximum Test Load(front) +7000Pa(1461b/ft2) Labor Warranty(yrs) 0 25 10 ry z W } O s _�_ ...a♦ ,� L z Temperature coefficient of P. -0.24% o J t t I ♦s - �. - _ _� -,,,y,�iac Maximum Test Load(rear) -4000Pa(83.41b/ft) Power in 98% 98% 98% t`d LU z , ti Temperature coefficient of V. -0.24%/K CC O f- t Max Series Fuse Rating 25A Temperature coefficient of Ix 0.04%/K Annual Degradation 0.25% 0.25% 0.25% 0 1•.a r -- - - _ - -� �` �� .,fir-SEyrl�+± '�'- Max Reverse Current 25A Q J •ln to alvecoerfidmts strtedae ureavawes d _ � 7tiF, • mP•r Power 92% 92% 92% ti •.rti _ __- ,s---•.: _ - •seen,naeanonneraeNnrrrwnmgireuucm� ¢ - _ �w- Dw4pbad-Tmtbad/t5(saretyrader) REC PraTrust Warranty apPlles only rarQ REC palls nKtaAed by an REC CMified ��•�// �- `�- _ - - - DELIVERY INFORMATION L1- O O 5,"C o5ysmSlaaWhwill[mdt .Seew eggap.Immrordrtits. f T T Panels per Pallet 33 Panels per 40 ft GP/high 594(18Pallets) a U Z cube container _`•�' v e - a Panels per 53 ft truck 792(24 Pallets) •�►s'r. w -. r.�.-_ .� vSi��. _��a! _ cures ..'`3;:.zli+ 'a� A,ailablefrom. Typical low irradiance performance of module atSTC: ! , < 22.6%MAX.EFFICIENCY REC 450 -470 WP SHEET NAME .•, • COEFF.• PROTRUST _ roeaRe(w/�M SPEC SHEET HETEROJUNCTION TECHNOLOGY , • •• _•, 1 • Fou,dedin 1996,RECGruup isan ntenationalpio eringwiaremrgycomparry dedicated to empoweringconsumerswtthclean affordable REC Solar PTE.LTD. solar power.As Solaes MostTrustecL REC is committed to high quality,nnovatlort and a tow carbon footprint in the solar materials and solar 20Tuas SouMAve.14REC Panels itmanufactures.headquartered in Norway with operational headquarters in Singapore.REC also has regional hubs In North America, Sngap-637312 SHEET SIZE EuopG and Asia-Pacific postaeecgwpn.ca wwwrecgroup.corn ANSI B 11" X 17" SHEET NUMBER PV-6 Data Sheet IQ7X Microinverter HARVEST Enphase Microinverters HARVEST POWER LLC Region:AMERICAS INPUT DATA(DC) IQ7X-96-2-US 2941 SUNRISE HIGHWAY ISLIP TERRACE,NY 11752 Commonly used module pairings' 320W-460W TEL:(801)989-3585 Module compatibility 96-cell PV modules r_ bske:www.harvest owecne_t Maximum input DC voltage 79.5V ��) `h Peak power tracking voltage 53V-64V Operating range 25V-79.5Vy. Min/Max start voltage 33V/79.5V - Q Max DC short circuit current(module Isc) 10A j ',:;: �• The high-powered,smart grid-ready // `w• e t11 IQ7X Microinverter Overvoltage class DC port1'- n IQ7X Microinverter dramatically simplifies the DC port backfeed current oA installation process while achieving the highest PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit system efficiency for systems with 96-cell modules. OUTPUT DATA(AC) @ 240VAC @ 208VAC Peak output power 320VA 'f` 1� kL VERSION Part of the Enphase Energy System,the IQ7X Maximum continuous output power 315VA vr� >` IPTION DATE Rev. Microinverter integrates with the IQ Gateway, Nominal(L-L)voltage/range' 240W211-264V 208V/183-229V BLDG.PERMIT 07/22/2025 0 IQ Battery,and the Enphase Installer App monitoring Maximum continuous output current 1.31A(240VAC) 1.51A(208VAC) Nominal frequency 60 Hz and analysis Software. Extended frequency range 49-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms The IQ Series Microinverters extend the reliability Maximum units per 20A(L-L)branch circuit3 12(24oVAC) 10(208VAC) standards set forth by previous generations and Overvoltage class AC port III undergo over a million hours of power-on testing, AC port backfeed current 18 mA Power factor setting 1.0 enabling Enphase to provide an industry-leading Power factor(adjustable) 0.85 leading...0.85 lagging warranty Of up to 25-years. EFFICIENCY @240VAC @208VAC CEC weighted efficiency 97.5% 97.0% MECHANICAL DATA Ambient temperature range -400C to+60°C Relative humidity range 4%to 100%(condensing) Easy to Install Connector type(IQ7X-96-2-US) MC4(or Amphenol H4 UTX with optional Q-DCC-5 adapter) PROJECT NAME Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Lightweight and simple Weight 1.08 kg(2.381bs) Faster installation with improved,lighter two-wire cabling Cooling Natural convection-No fans (n O Q Built-in rapid shutdown compliant(NEC 2014,2017&2020) Approved for wet locations Yes � CD J Pollution degree PD3 Ir Q Enclosure Class II double-insulated,corrosion resistant polymeric enclosure � - M CD _ Efficient and Reliable Environmental category/UV exposure rating NEMA Type 6/outdoor Q � CD J Optimized for high powered 96-cell"modules FEATURES z = O Highest CEC efficiency of 97.5% Communication Power Line Communication(PLC) LIJ cy) W O J Monitoring Enphase Installer App and monitoring options J }- CD (n (f) More than a million hours of testing Compatible with IQ Gateway Q u) z CD Class II double-insulated enclosure Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break UL listed disconnect required by NEC 690. z Iii J w r } O Compliance CA Rule 21(UL 1741-SA),IEEE 1547:2018(UL 1741-SB,3r°Ed.) c) ~ Z HEI Rule 14H SRD 2.0 ( ) r lr O J Smart Grid Ready UL 62109-1,FCC Part 15 Class B,ICES-0003 Class B, — 0 CD CAN/CSA-C22.2 NO.107.1-01 CD ~ p Complies with advanced grid support,voltage and frequency This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, T NEC 2017,and NEC 2020,section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV = U ride-through requirements Systems,for AC and DC conductors,when installed according manufacturer's instructions. rJ z � Remotely updates to respond to changing 7- grid requirements a- Q Configurable for varying grid profiles U Q Meets CA Rule 21(UL 1741-SA)and 1.Pairing PV modules with wattage above the limit may result in additional clipping losses.Seethe compatibility calculator at httos//Iink.enohase.com/module-compatibility. IEEE 1547:2018(UL 1741 SB,31 Ed.) U` 2.Nominal voltage range can be extended beyond nominal if required by the utility. SHEET NAME 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. •The IQ7X is required to support 96-cell modules. To learn more about Enphase offerings,visit enphase.com SPEC SHEET To learn more about Enphase offerings,visit enphase.com E N P H AS E. ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ7,IQ7+,IQ Battery,Enphase Installer App.IQ Gateway, EN P HAS E IQ7X DS-0099 EN US 12 27-2022 `/ and other trademarks or service names are the trademarks of Enphase Energy,Inc. `/ SHEET SIZE IQ7X-DS-0099-EN-US-12-27-2022 ANSI B 11" X 17" SHEET NUMBER PV-7 ' Q ' •�• U N I RACHARVEST POWER ILLC SOLARMOUNT .. :. BETTER DESIGNS TRUST THE INDUSTRYS BEST DESIGN TOOL CONCEALED UNIVERSAL Start the design process for every project in our U-Builder on line design tool. ENDCLAMPS It's a great way to save time and money. BETTER SYSTEMS ONE SYSTEM-MANY APPLICATIONS Quickly set(nodules flush to the roof on steep pitched roofs.Orient a large variety,•!IT ®� of modules in Portrait or Landscape.lilt the system up on flat or low slow roofs. END CAPS INCLUDED � Components available in mill.clear,and dark finishes to optimize your design financials and aesthetics. WITH EVERY ENDCLAMP BETTER RESULTS - MAXIMIZE PROFITABILITY ON EVERY JOB CONCEALED Trust Umrac to help you minimize both system and labor costs from the time the job is UNIVERSAL quoted to the time yourtcamsget off the roof.Faster installs.Less Waste.More Profits. CLAMPS UNIVERSAL SELF iFUNIRAC BETTER SUPPORT STANDING MIDCLAMPS 25 WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM Professional support for professional installers and designers.You have access to PROJECT YEAR our technical support and training groups.Whatever your support needs.we ve got OPTIONAL you covered.Visit Uairac.com/solarnrount for more information. • FRONT TRIM futt-SYS11 • ' WARRANTY U BUILDER ONLINE DESIGN • • TOOL SAVES TIME&MONEY ILL o BONDING&GROUNDING Vrsddeslgn.umrac.com • MECHANICAL LOADING CD eSYSTEM FIRE CLASSIFICATION LLJ • • • CO CO � • UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT • 1 ( UNMATCHED CERTIFIED ENGINEERING BANKABLE DESIGN PERMIT EXPERIENCE QUALITY EXCELLENCE WARRANTY TOOLS DOCUMENTATION . • . I I I I 1' I TECHNICAL SUPPORT CERTIFIED QUALITY PROVIDER BANKABLE WARRANTY Uri technical support team is dedicated to answering Unirac isthe only PV mounting vendor with ISO Don't leave your project to chance.Unirac has the questions&addressing issues in real time.An online certifications for 9001:2008.14001:2004 and OHSAS financial strenglhtoback our products and reduce your risk. of THE PROFESSIONALS' CHOICE FOR RESIDENTIAL RACKING seamy df eocumends including 1800120m1 which means .T es deliver the hionsd standards Have peace ohnmdknowmg you areOUNTi coveredbra25y year _ stamped letters and technical data sheets greatly for fit.form.anrl function.These certifications demonstrate exceptional quality.SOLARMOUNTisroveredhya25year simplifies your permitting and project planning process. our excellence and commitment tofirstcfass business practices. limited product warranty and a 5 year limited finish warranty. IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII.II.i,ll,ii iii,ilil IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII BEST INSTALLATION EXPERIENCE•CURB APPEAL*COMPLETE SOLUTION•UNIRAC SUPPORT ENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN FOR QUESTIONS 0R CUSTOMER SERVICE VISIT UNIRAC.00M 0R CALL (505) 248-2702 FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248 2702 1 � Ff Unirac State Letter-NY HARVESTIDf%`i Tectonic I Tectonics Tectonic WO#:1224 HARVEST POWER LLC August 12,20 2024 = 2941 SUNRISE HIGHWAY ISLIP If+R(+l/OlYfgwS.fKffigw+(SlW(E 14[TI[I(SWYT6n1[f((R fNl•i;(a,. TERRACE,NY 11752 v TEL:(801)989 3585 August 12, 2024 ■ Metal Roof: Standing Seam Attachments, PM-9000s, and PM Adjust Slotted �� . ,�',-. -- :www.narvesr owecner ■ Tile Roof: Solar hooks, Flashkit Tile Replacement (TR) ? Unirac Attn: Engineering Services Department The U-Builder Tool should be used under the responsible charge of a registered Cn Z ITI 1411 Broadway Boulevard NE professional engineer required by the authority having jurisdiction. The design tool Albuquerque, NM 87102-1545 and Unirac do not evaluate the existing roof structure, or the PV panels themselves. �1, TEL: (505)242-6411 See the construction and installation drawings and manuals for additional 0298 information provided by Unirac. O� /7 RE: ENGINEERING CERTIFICATION LETTER FOR THE UNIRAC SOLARMOUNT (SM) V11 Y ROOF PV PANEL SUPPORT SYSTEM Sincerely, OF NEtti VERSION STATE: NEW YORK C� y DESCRIPTION DATE REV. TECTONIC WORK ORDER#: 12557.25 Tectonic �Po��o A GUq` �9� BLDG.PERMIT 07/22/2025 0 The Unirac SOLARMOUNT (SM) Photovoltaic Panel Support System is a proprietary � 1 a, framed photovoltaic panel support system that is installed on a roof. Tectonic 1; UJ z Engineering Consultants, Geologists & Land Surveyors, D.P.C. (Tectonic) has reviewed the SM design methodology along with the U-Builder tool; a Unirac online p 07124g design tool. The review included the following SM products, SM Light, Heavy Duty, Pess1 08/12/2024 and Standard rail with both the standard and pro hardware. Antonio A. Gualtieri, P.E. Tectonic has determined that the design is a rational approach and follows the Executive Vice President structural requirements of the following reference documents: Codes/Standards: • 2020 Building Code Of New York State. PROJECT NAME ■ 2018 International Building Code by International Code Council. Q ■ ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures, by Cn o 0 American Society of Civil Engineers with provisions from SEAOC PV-2-2017. } O • 2020 Aluminum Design Manual, by Aluminum Association. LO O O M This letter certifies that the structural analysis of the racking members,connections, o and components directly related to Unirac's system are in compliance with the z CD W rn W O above codes. The design methodology is acceptable under components and J J o C/) Cn cladding loads associated with the building's roof structure when the system is Q C/) Z CD L- installed in accordance with manufacturer specifications. If the loading criteria does z LU r` p not meet Unirac's specifications, owner shall contact Unirac for a site-specific J W 0) F— certification. U o � o J Cr O o O Attachments approved for the SM system to the structure include the following = _ and is installed per Unirac's U-Builder report and installation guides: C) I`_ Z = ■ Shingle Roof: L-Foot Flashkit Pro, Standoffs, Flashloc Comp, Flash Loc Duo, C) Q Q and Flash Kit Pro SB SHEET NAME Project Contact Info Project Contact Info SPEC SHEET 1279 Route 300 1 Newburgh,NY 12550 1279 Route 300 1 Newburgh,NY 12550 845.567.6656 Tel 1 845.567.8703 Fax 845.567.6656 Tel 1 845 567.8703 Fax SHEET SIZE tectonicengineering.com tectonicengineering com page 2 of 2 ANSI B Equal Opportunity Employer Equal Opportunity Employer 11" X 17" SHEET NUMBER PV-9