Loading...
HomeMy WebLinkAbout52482-Z J ho��OF SOUTyo`o Town of Southold * * P.O. Box 1179 ion 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46775 Date: 01/12/2026 THIS CERTIFIES that the building AS BUILT HVAC Location of Property: 32645 Route 25 Cutchogue, NY 11935 Sec/Block/Lot: 97.-5-4.7 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 10/09/2025 Pursuant to which Building Permit No. 52482 and dated: I 1/20/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "As built" heat pump at existing commercial building for CityNM as applied for. The certificate is issued to: W M S Realty Inc Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 52482 12/10/2025 PLUMBERS CERTIFICATION: 1 Auth d Si nature ofSO&Tyo`o TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD, NY *�QUlm. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52482 Date: 11/20/2025 Permission is hereby granted to: W M S Realty Inc Attn:Wms Realty Inc Mineola, NY 11501 To: legalize an "as built" heat pump as applied for. Premises Located at: 32645 Route 25, Cutchogue, NY 11935 SCTM#97.-5-4.7 Pursuant to application dated 10/09/2025 and approved by the Building Inspector. To expire on 11/20/2027. Contractors: Required Inspections: Fees: As Built Commercial $600.00 CO Commercial $100.00 Lginspector tal 700.00 ----- as � o Town Hall Annex Telephone(631)765-1802 54375 Main Road G Q P.O.Box 1179 Southold,New York 11971-0959 �lij'COUNT` l BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: W M S Realty Inc Address: 32645 Route 25 City: Cutchogue st: NY zip: 11935 Building Permit#: 52482 Section: 97 Block: 5 Lot: 4.7 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Electrician: AS BUILT License No: N?A SITE DETAILS Office Use Only Commercial X Indoor X Basement X Service Solar Residential Outdoor X 1st Floor X Pool Battery Storage As-built X Renovation 2nd Floor Hot Tub EV Charger New Addition Attic Spa Generator Survey ix I Mezzanine Garage Dock INVENTORY Service 1 ph In-wall Heater Recpt Ceiling Fixtures Smoke Detectors Pump Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures CO Detectors Heater Main Panel A/C Condenser Single Recpt RecessdFixtures Combo Smoke/CO Transformer Sub Panel A/C Blower 1 Range Recpt Ceiling Fan Heat Detectors Salt Gen Transfer Switch Mini Split 1 Dryer Recpt UC Lights Fridge AutoCover ARC Blower Heads Switches Pucks Lights Dishwasher Mini Fridge GFI AC Disconnect 1 Emrgency Strobe 4'LED Microwave Garbage Disp. ARC/GFI ERV Exit Lights Bath Exhaust Hood Dehumidifier Other Equipment: Ducted Minisplit Notes: " AS BUILT NO VISUAL DEFECTS " HVAC Inspector Signature: Date: December 10, 2025 pF SOUIyO{o * * TOWN OF SOUTHOLD BUILDING DEPT. co 631-765-1802 INSPECTION - I FOUNDATION 1ST/ REBAR [ ]' ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE& CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION : [ ] PRE C/O [ ] RENTAL REMARKS: 04 k)414 el t I r DATE INSPECTOR OF SOUly�lo — - -- - - — # # TOWN OF SOUTHOLD BUILDING DEP . "cou 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] .FINAL [ ] FIREPLACE& CHIMNEY [ ] -FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] -ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: C14 IN46r �(ojgl m 66 / (A e11-3 a e 2 le S DATE INSPECTOR OF SOUTH°� # TOWN OF SOUTHOLD BUILDING DEPT. courm, 631-765-1802 INSPECTION [ ]. FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I ULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL 'CV,rh? [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE_RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [- ] PRE C/O [ ] RENTAL REMAARKS: l np T g 0? / AA Y r V' DATE i INSPECTOR I ,ram''-"• ' •;� fll�'' } ►�� s r��:1 ;. �.. i i�• y 1 T tZ s'••VSt ` �' ' •�•.�,rtS t +•?.( r is( �� '•'";hlii z , '"�an�r� •it __-r- -S� _.. �,;. -. .- �' - x • .> ham... - - - I - \� M 3 FUP TSUMM AWSMGF L „1b mom 4a i C4 yR r cn . �s � FUI_am )TSU r" R"► r�20=wn— �' rl iEINONWNO ?sramcE -, S FIELD INSPECTION REPORT DATE COMMENTS r n FOUNDATION (1ST) ---- - — -- --- -- a ------------------------------------ --- ----- — - - — --- c FOUNDATION (2ND) � s ROUGH FRAMING& - -- — — „� PLUMBING INSULATION PER N. Y. - - STATE ENERGY CODE --- y FINAL ADDITIONAL COMMENTS wzb'g-v- alITIOCA �� - --- w b o�SUFfI)L�coG TOWN OF SOUTHOLD—BUILDING DEPARTMENT y y= Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631)765-1802 Fax(631) 765-9502 htips://www.southoldtomLnny.gov Date Received APPLICATION FOR BUILDING PERMIT / For Office Use Only It fL' �' SLIJ " I u PERMIT NO. Building Inspector: OCT' - 9 2025 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not-the owner,an Owner's Authorization form(Page 2)shall be completed. Duticlert9 Department Tc"'rig Cif'.30Uffiold Date:09/24/2025 OWNER(S)OF PROPERTY: Name:WMS Realty Inc 1-iC #1000--097-00-05-00-004-007 Project Address:32645 Main Road, Cutchogue New York 11935-1364 Phone#:516-284-0400 TFM'W1l-kambrosino@accresinc.com Mailing Address:155 1st Street, Suite 104 - Mineola New York 11501 CONTACT PERSON:. Name:Paula Nolan of Paula Nolan LLC Permit Expeditor (CALL FOR INSPECTION) Mailing Address:33 Mayflower Lane - East Setauket, New York 11733-3303 Phone#:631-327-1072 Email: DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email. CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: [i]Other HVAC system Installed Will the lot be re-graded? ❑Yes ❑No Will excess fill be removed from premises? ❑Yes ❑No 1 PROPERTY INFORMATION Existing use of property:CITY MD Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to ZONE B this property? E]Yes *No IF YES, PROVIDE A COPY. D Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors on premises and In building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):Paula Nolan RAuthorized Agent ElOwner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF IM 55 44) --4, Paula Nola being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Permit Expeditor . (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of 20 P hior Ell NOTARY PUBLIC.STATE OF NEW YORK Reglstmtlon No.01RU4996MI Oualified In Nassau County PROPERTY OWNER AUTHORIZATIO Commission Expires May 26,2028 (Where the applicant is not the owner) 1, residing at I IST ( *- S eu.3(9-1 do hereby authorize Paula Nolan to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date +C*1 &J . a, Print Owner's Name 2 Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) 1, �VjSt�'` Av-A,,6D5 " residing at 15-5 1 S4- S--,J� (Print property owner's name) (Mailing Address) do hereby authorize PAULA NOLAN (Agent) to apply on my behalf to the Southold Building Department. (O er's Signature) (Date) (Print Owner's Name) Q�QS%IFF0(,r40h BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD o Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 �c APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: CA, M1) — UJ L S &-C�l Address: 3,96 ZK fld f 1 )2)01 Cross Street: Phone No.: S iCp • 2 -� �� Bldg.Permit#: 52 email: �� 110 Si. i n , Tax Map District: 1000 Section: ' Block: C7 f 00 Lot:® 'UO BRIEF ��DESCRIPTION OFQW,�ORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): -5�L"LP '- lJ- cLk I P"L Square Footage: Circle All That Apply: Is job ready for inspection?: EYES [] NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals D 1 2 D H Frame Pole Work done on Service? Y RN Additional Information: PAYMENT DUE WITH APPLICATION IF COX LANE- �g,�,w V, L AN 0 0 F m I I s r R I'M WI I.......... prV ij ji 7:, 3 2 mi 74, Ire o-�7 , 42 40 4 "j, H if , *,Sow 44#0 rp, 7i -Oro 40 z, kom v k, 2 . 3 col" I%/w wo Im I 11ZI 30 33 M, 4 4 low cl-------- 44 47� rot* 27 s/w etc" 9 2 6 37 ........... 2, 2( Ile raw 23 jo* .9 51 0 4 -7 4,b PC 43 * 32 30 W, LANO OF, OLS E N' F EL Y 0 F? (JRV w C ORPO R A TI 0 N A T CUTCHOGLIE TOWN 0*** SOUTHOLD T T UFFOLK COUN INI CERTI Ft E0 100,0 97 05 p 0 4 1 w con P �ASCALE :20 A y 9 9 8 ,6 , JULY IlBs 19 6 ': AREA 5 51 $0,0 AUG 4* 1986 jMLOING A REA r L Pt OW 909 A h R 0,A 1� N Y 1 9 bL 4Q PRODUCTS SERVICE&SUPPORT COMPANY LOCATE A CONTRACTOR Heat Pump for Small Capacity Type J-1VS Series AOU60RLAVM4 (Retired) Features - Up to 15 indoor units can be connected(5Ton)* . Improvement in the connectable indoor unit capacity range U Long piping design 1 High energy efficiency M Locate a Contractor COMPLY WITH ALL CODES OF Outdoor Unit: Download NEW YORK STATE &TOWN CODES AOU60RLAVM4 catalogues m AS REQUIRED AN r CONDITIONS OF SOUT,OLD TOWN ZBA so OLD TOWN PLANNING BOARD UTHOLD TOWN TRUSTEES XS -yS,DEC0 APPR07ED AS NOTED $MOLD HP0 <2 DA SCHD V FEE=, BY NOTIFY BUILDING DEPARTMENT AT OCCUPANCY OR 631765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: USE IS UNLAWFUL 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE WITHOUT CERTIFICATE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION OF OCCUPANCY 4. FINAL-CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OFTHE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR ELECTRICAL DESIGN OR CONSTRUCTON ERRORS INSPECTION REQUIRED Specification Rating Capacity Range 5 Ton HP Phase Single-phase 1 Power source Voltage 20B/230 V Frequency 60 Hz Air Flow Rate 4,827 CFM 8200 m3/h Cooling 57 dB(A) Sound Pressure Level — Heating 57 O(A) Maximum external static pressure 012 in.WG 30 Pa Compressor motor output 3.75 kW Heat exchanger fin Blue fin Height 52-8/16 inch 1334 mm Net Dimensions Width 38-3/16 inch 970 mm Depth 14-9/16 Inch 370 mm Net Weight 123 kg kg �— Type R410A Refrigerant Charge 11.68 lbs 5.3 kg Liquid cp3/8 inch cp9.52 mm Connection Pipe Diameter Gas cp3/4 inch cp19.05 mm Total pipe length 591 ft. 180 m Max.height difference 164/131 ft. (Outdoor unit:upper/Lower) 50/40 m Cooling 23 to 115°FDB -5 to 46°CDB Operation Range Heating -15 to 70°FDB -26 to 21°CDB Note: Specifications are based on the following conditions. Coaling: Indoor temperature of 27°CDB/191CWB,and outdoor temperature of 35°CDB/24°CWB. Heating: Indoor temperature of 20°CDB/(15°CWB),and outdoor temperature of 7°CDB/6°CWB. Pipe length: 7.5 m;Height difference between outdoor unit and indoor unit:0 m.The protective function may work when using it outside the operation range. STon model Dimensions Outdoor Unit:AOU60RLAVM4 (unit:MM) 166 650 154 v v m 36 970 32 370 12 Terminal blocks(Transmission) *Terminal blocks(Power) I m I ® 3-Wayvalve(Liquid) o 3 Wa valve'(Gas) 0�g CDCableIL tt —or N ^ N 9 N ry N NN65 �Pj Cable ort o028 Cable ort028(Cable part) 89 Pie ort 27Cable port) 21028 Cable port) Pie oft — a e 65 15 �N a 0 50 438 ) Pipe&cable port 622 Service&Support j Download i Contact PRODUCTS SERVICE&SUPPORT COMPANY LOCATE A CONTRACTOR Airstage(VRF Systems) Indoor Unit Multi Position Air Handling Unit Model >- 208/230V Single-Phase ARUX12TLAV2 ,R ARUX18TLAV2 • ; ARUX24TLAV2 •• •• •• •• •' ARUX30TLAV2 Download: ARUX36TLAV2 Catalog m ARUX48TLAV2 ARUX60TLAV2 Specifications Model name ARUX12TWV2 ARUXI8TWV2 ARUX24TWV2 I ARUX30TWV2 I ARUX36TWV2 ARUX481WV2 ARUX60TWV2 ' Posner supply 1 phase-2081230 V 60 Hz Available volts a ran a I87-253 V Cooling etuth 12.000 18.000 24.000 30.000 36.000 48.000 60.000 Capacity kW 3.5 5.3 7.0 8.8 10.6 14.1 17.6 Stuth 13.500 20,000 27,000 34,000 40,000 54,000 67,000 Heath., kW 4.0 5.9 7.9 10.0 11.7 15.8 19.6 Input power W 77 99 148 180 241 322 521 Static pressure range In1YG(Pa) 0.10 to 0.80(25 to 200) Standard static pressure In1YG(Pa) 0.50(125) HIGH 350(595) 500(850) 650(1,104) 880(1,495) 1 1,050(1,784) 1,400(2.379) 1,700(2,888) Ahnmv rate MED CFM(m31h) 320(544) 450(765) 1 59011.6021 80011.359) 1 950(1,614) 1 1.26012.1411 1.550(2,633) Fan LOW 290(493) 400(680) 510(866) 730(1,240) 1 850(1.444) 1.130(1,920) 1,340(2,277) Type•Oty Sirocco•I Motoroutput W 249 373 560 NIGH 37 18 40 42 44 46 48 Sound pressure level' h1ED d8(A) 35 36 37 40 42 44 46 LOW ]] 14 34 38 40 42 42 Length in(mm) 16(406) 16 406 16 406 16(406) 16 406 17-12 446 77.12 446 Fin pitch FP1 16 16 16 14 14 14 14 Heat Roses•Sta es 4•14 2•18 2•18 3.22 3•22 3•30 4.30 � exchanger type Face area (t2 m2) 2.6(0.24) 3.3 0.31 3.3(0.31) 4.0(0.38) 4.0 0.381 6.0(0.56) 6.0 0.56 Pipe type Material Grooved H-in(Copper) Fin Type(Material) Lower(Aluminum Enclosure Material Painted galvanizedsteel sheet Color Gray 43•17-1/2.21 48.21•21 58.314.24.12•21-114 Dimensions Net In(mm) (1.092 s 444•533) (1,219.5)3•533) (1,492•622•552) (H•W•D) Gross 45.19-0/4.26.3/4(1,143•502.6791 52.23.26-3/4 11,321•584.679) 63.27•27.12(1600.686.699) j Net 100(45.4) 102(46.3) 102(46.3) 126(57.2) 126(57.21 172(78.0) 181(82.1) i weight Gross 1b(kg) 1l l(50.3) 113(51.3) 113(513) 139(63.0) 139(63.0) 187(84.8) 196(88.9) i Conn ectlon pipe Uquid In(mm) 0 114(6.35) 0114(6.35) 0114(6.35) 0 78(9.52) 0318(9.52) 0 3/8(9.52) 0318(9.52) diameter Gas 1 0 112(12.70) 0 112(12.70) 0 112 112.701 0 518(15.88) 0 518(15.88) 0 518(15.88) 0 518(15.88) Connection method Brazing Drain hose in(mm) I I.D.:0 314(19.05) Specifications are based on the following.conditions: • Cooling:Indoor temperature of 80°FDB/67°FWB(26.7°CDB/19.4°CWB),and outdoor temperature of 95°FDB/75°FWB(35°CDB/23.9°CWB). • Heating:Indoor temperature of 70°FDB/60°FWB(21.1 °CDB/15.6°CWB),and outdoor temperature of 47°FDB/43°FWB(8.3°CDB/6.1 °CWB). • Pipe length:25 ft(7.5 m),Height difference:0 ft(0 m).(Between outdoor unit and indoor unit.) *:Sound pressure level: • values in manufacturer's anechoic chamber. • Because of the surrounding sound environment,the sound levels measured in actual installation conditions might be higher than the specified values here. Dimensions �--Width—� �---Depth--� o . C. s m x f7 a ARUX12-18-24TLAV2 I ARUX30-36T1AV2 ARUX48.6011AV2 ffH6h, 17.5 in.(444 mm) 21 in.,(533 mm) 24.S in.(622 mm) 'rag, �g 43 in. 1.092 mm) 48 in. 1.219mm S8.75 in. 1.492 mm 21 in.(533 mm) 1 21 in.(S33 mml 21.75 in.(533 mm) Feature Wide range Capacity Line up & High Static Pressure • Available from 12K to 60 K Models. • Modular design;up,left,and right configurations. • Compact footprint-as small as 43"tall and 17-1/2"wide(for up to 2-ton models) • Static pressure of up to 0.8"W.0 • External filter boxes with up to 2"filters available • Control 3rd party auxiliary heater based on various control methods • Indoor unit sound levels as low as 33 dB(A) • Airflow up to 1700 CFM • Modular drain hole configurations • Multiple control options available Downflow Kit for ARUX Models Convert the Multi-Position Air Handling unit to down-flow configuration with the help of this kit. Features 1.Easy installation 2.Engineered for better condensate management Model Downflow Vit ARUXI2TLAV2 UTD-DFMSAI ARUX18TLAV2/ARUX24TLAV2 UTD-DFMSA2 w ' It,. I i ARUX30TLAV2/ARUX36TLAV2 UTD-DFMMAI ARUX48TLAV2 UTD-DFMLA1 ARUX60TLAV2 UTD-DFMLA2 I j Service&Support 1 Download I ' Contact COMMERCIAL PRODUCTS RESOURCES AND TOOLS SERVICE&SUPPORT COMPANY AIRSTAGE(VRF Systems) Why VRF? Downloads FOLLOW US Applications and Solutions Contact O Locate a Contractor Support Tool Fujitsu Commercial Financing Training MEDIA LIBRARY AIRSTAGE on Broadway RESIDENTIAL Select a regionlcountry I © United States I English Terms of Use I Privacy I Contact 1 Support Tool 0 1996-2025 FUIITSU GENERAL.