Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
52427-Z
�oAQF SOUT�Olo Town of Southold * * P.O. Box 1179 r o 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46764 Date: 01/07/2026 THIS CERTIFIES.that the building SOLAR PANEL Location of Property: 2205 Gillette Dr East Marion, NY 11939 Sec/Block/Lot: 3 8.-3-14 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 10/15/2025 Pursuant to which Building Permit No. 52427 and dated: 10/31/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof mount solar to existing single family dwelling as applied for. The certificate is issued to: John Nanas , Vasiliki Nanas Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 2025-1165672 12/5/2025 PLUMBERS CERTIFICATION: (Aulked Signa e ofSD�Iyo� TOWN OF SOUTHOLD BUILDING DEPARTMENT N Y `� • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52427 Date: 10/31/2025 Permission is hereby granted to: John Nanas 922 80th St Brooklyn, NY 11228 To: Install roof mount solar to existing single family dwelling as applied for. Disconnects must be located on the exterior, labeled, and readily accessible. Premises Located at: 2205 Gillette Dr, East Marion, NY 11939 SCTM#38.-3-14 Pursuant to application dated 10/15/2025 and approved by the Building Inspector. To expire on 10/31/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 CO-RESIDENTIAL $100.00 Total $200.00 Building Inspector .. ''r ..:itr:N�- y:.w=•°kx- ' s - rrri>� , .,. `id+' , Y y p r L is Elec acallns e Inc. 2025-1165672 t. Southold Town Of P' ` L Inspector: 115 K„ (. Issue Date: 12/5/2025 �' New York Board of Fire Underwriters DEC 2 2 2025 3R 300 East Meadow Avenue ' ` 0• cr East Meadow,NY 11554 Office:(516)794-0400(631)650-0200 Website:www.eiiny.com Mail To: Property Address: 91 �n \ EmPower Solar John Nanas Gregory Sachs,PE 2205 Gillette Drive ' r` i 1000 Fulton Street East Marion NY 11939 Farmingdale NY 11735 .�� License# Timothy M.Crotty ME-65990 ELECTRICAL APPROVAL CERTIFICATE Section: 038.00 Block:03.00 Lot: 014.000 Permit: t AREAS LISTED BELOW ARE APPROVED BY Inspection \ AND FOUND TO BE IN COMPLIANCE WITH THE BUILDING CODE OF NYS y r. AND CURRENT PROMULGATED NEC r No visual defects were found for the electrical inspection provided.No obvious unsatisfactory conditions 4 l ' were found in the areas herein below only. Residential Inspection Final Approved 12/3/2025 �•' 11kW PV Grid System Of(25)HiN-T440NF(BK)W ACPV Modules And(25)Enphase IQ8MC-72-M-US-240 0.320 VA Microinverters.' �' .y •ice: \\\ ■ "9 `\ This electrical inspection and certificate does not take into account any FEMA,NYS and local flood elevation requirements.It is the responsibility of the property owner to determine if flood elevation Y: requirements apply. NYEIFU and Ell are not responsible for any Flood Elevation requirements. r' Therefore this electrical certificate is only for compliance of NYS Electrical and NEC Codes. as Richard M. Bivone Philip Goehring,Jr. ' " ? s President Chief Electrical Inspector w/ p ■ �` q , This document features a tamper proof Quick Response code which contains the encrypted original data submitted when certificate was issued. ,7►;i 73 `/: � rr• , car' a �s a/ .. - �`rs Nti�,9,/,i�s:��- a .y� �fr ..�y�1.. /.Y� ,7;. Yv1' ,•„ 1`I A'/� „ �r� a.QY '�. .p} `�• 1• .�;�r a�:�•I,y1;.r a I•,0,0/?>> �a�1;,d,��.Cf►>> aa;':elti1;6i aa✓�0.1;'�ir :�;e;�i;:! 1. ELECTRICAL INSPECTORS, INC. is not responsible for the existing conditions located at the subject premises. 2. tI ECIRICAL V*l�M%671:(, RS, INC. is not responsible for corrections, upgrading or replacement of existing .,..,,_ electrical.violations.'lititlii ',�iibi&t premises. Any corrective work shall be solely the responsibility of the property owner. ELEcTiuCA.,,INSPECTORS, INC. DOES NOT WARRANTY OR UNDERWRITE THE EL;'E'C+7'kl(2ALC, 61VI31`I'li: V i ATTHE PREMISES. 3. ELECTRICAL INSPECTORS, INC. only rec6gnizes the National Electric Code, the Building Codes of New York Stag all volumes and Local Nhinicipal Codes, as Authorized by The Department of State Codes Division, via Village,Mown or Cily Board Itcsolution. 4. AN ELECTRICAL SURVEY consists ofa visual examination of the premises ONLY: Electrical Inspectors Inc. will comply with the requirements of NFPA 73, latest edition Chapter 1, Section 1-1, 1-2. If violations exist, a Notice of Violation (NOV) Will be issued requiring corrections by a licensed electrical contractor. After the violation has been corrected,a re-inspection will be conducted and if approved a certificate shall be issued. 5. AN ELECTRICAL CLOSED WALL INSPECTION consists ofa visual examination of the area requested ONLY: Electrical Inspectors Inc. will comply with the requirements of NFPA 73,latest edition Chapter 1, Section 1-1, 1-2. lhviolatimis exist, a Notice of Violation (NOV) will be issued requiring corrections by a licensed electrical contractor. Alter the violation has been corrected, a re-inspection will be conducted and if approved a certificate shall be issued. (. A SURVEY CERTIFICATE does not examine Tile actual wiring or devices unless all walls are opened and wires and devices are exposed prior to the survey being conducted. 7. A CERTIhICATI!: is nun-iransl'crablc. 8. AN FLECTRICAL INSPECTION consists ol'an examination of wiring and installations during the rough stages ol'conslruction. A 11cr completion of-the construction a final inspection will be conducted at which time a certificate will be issued provided no violation exists. In the event an inspection is not requested during the rough stages of construction ELECTRICAL INSPECTORS,INC. will perform a CLOSED WALL SURVEY that consists ofa visual inspection ofthe wiring and installations only. Since access is limited, ELECTRICAL INSPECTORS, INC.shall bear no responsibility iur ally defects or violations at the premises. 9. ELECTRICAL INSPEC:'.MHS, INC. shall not be responsible to remove any walls in order to conduct an electrical inspection. 10. E LECTRICAL I INS t'ECTC°I S, INC. will only release information, certificates and reports to the applicant after payment lbr services rendered have hcen paid in full. 11. ELECTRICAL INSPECTORS, INC. assumes no liability Ibr the results of its inspections. 12. The aoreen(etit may not h(:ch<uiocd orally. 13.'The New 'Vork 3(w.6 Inc., is a subsidiary o1'I?leclrical Inspectors, Inc. It is fully operational and fiuictinn�d and ncrlorins electrical inspections as it always has. 14.The New York (,f Hire UL!tled—M-40-s, Inc. and Electrical Inspectors, Inc. inspects properties for compliance ,-vith the Building C'oa�--,o"the State oi*New York, counties and local electrical codes, as well as the promulgated NEC (NILIHOHLII islcctrical ('ode). zi SO(/T�O 7a # # TOWN OF SOUTHOLD BUILDING DEPT. coum, 631-765-1802 INSPECTION ' [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL <9044- [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR Gregory Sachs, � �h PE 4589 Austin Blvd., Island (516)-544-4592 Park, NY11SS8 permhtt|ng@empower-solaccom December l6, Z03S Town of Southold u Building Department 54375 Route 3S ' DEC1 7 �O�� ' "�" ' ' �,�^ (L�� Southold,iNY1197l � Ft. Permit#: 52427 2205 Gillette Drive East Marion, NY11939 Section: 038.00 Block:03.00 Lot: 0%4.000 To Whom It May Concern: The Solar Electric installation at 2205 Gillette0rive, East Marion, NY 11939 (NANAS Residence) has been inspected and meets the New York State Building Code standards for construction and the provisions ofAS[E7.The solar panels have been secured 10 the roof as per the manufacturer's attachment detail shown on the approved drawings, and are in compliance with the structural engineer's requirements.The project isconsistentvxiththespedficetions set forth in the permit application. Sincerely, SAC Gregory Sachs, PE ` FIELD INSPECTION REPORT DATE COMMENTS t FOUNDATION (1ST) J ------------------------------------ C FOUNDATION (2ND) �7 � z o ,Hv ROUGH FRAMING& PLUMBING ru H ((1 VJ r INSULATION PER N.Y. H STATE ENERGY CODE FINAL ADDITIONAL COMMENTS Q Zoo reC-4 !l 44 y I�Z- Gait k i 1 f b l & (l),? e z Q�m S� 5 , b � o x � H x d m b ouFFaoG TOWN OF SOUTHOLD—BUILDING DEPARTMENT y= Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 oy�o oo' Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only �j ?n,,5 PERMIT NO. ✓0? �4_ Building Inspector: Applications and forms must be filled out in their entirety. Incomplete 1 applications will not be accepted. Where the Applicant is not the owner,an V Owner's Authorization form(Page 2)shall be completed. Date:10/14/2025 OWNER(S)OF PROPERTY: Name:John Nanas SCTM#1000-038.00-03.00-014.000 Project Address:2205 Gillette Drive, East Marion, NY 11939 Phone#:917-400-4899 Email:john.nanas@gmail.com Mailing Address:2205 Gillette Drive, East Marion, NY 11939 CONTACT PERSON: Name:Ellen Bury Mailing Address:1000 Fulton Street, Farmingdale, NY 11735 Phone#:516-837-3459 ext_132 Email: ermittin _ em power-solar.com DESIGN PROFESSIONAL INFORMATION: Name:Gregory D Sachs Mailing Address: 1000 Fulton Street, Farmingdale, NY 11735 Phone#: 516-544-4592 Email:permitting@empower-solar.com CONTRACTOR INFORMATION: Name: EmPower CES, LLC Mailing Address: 1000 Fulton Street, _Farmingdale, NY 11735 Phone#:516-544-4592 Email:permitting@empower-solar.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: D Other solar $31,766.30 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ®No IF YES, PROVIDE A COPY. 8 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):Ellen Bury I7Authorized Agent ❑Owner Signature of Applicant: Date: 10/14/25 STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Ellen Bury (EmPower CES, LLC) being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 14th day of October 20 25 ��. E T�-- Notary Public im TATE OF NEW YORK Registrationo.01�'R001400 uffolk County �R PERTY OWNER AUTHORIZATION pires 10/03/2027( here the applicant is not the owner) John Nanas residing at 2205 Gillette Drive, East Marion, NY 11939 do hereby authorize Ellen Bury (EmPower CES, LLC) to apply on my behalf to the Town of Southold Building Department for approval as described herein. J�0mn�� 10/14/2025 Owner's Signature Date John Nanas Print Owner's Name 2 Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) John Nanas residing at 2205 Gillette Drive I, (Print property owner's name) (Mailing Address) East Marion, NY 11939 do hereby authorize Ellen Bury (EmPower CES, LLC) (Agent) to apply on my behalf to the Southold Building Department. jU V�/ JMA&r- 10/13/25 (Owner's Signature) (Date) John Nanas (Print Owner's Name) FLORENCE TRUDEL NOTARY PUBLIC,STATE OF NEW YORK Registration No. 01 TR0014007 Qualified in Suffolk County Commission Expires 10/03/2027 d 0S(o BUILDING DEPARTMENT- Electrical Inspector Gy TOWN OF SOUTHOLD o Town Hall Annex- 54375 Main Road - PO Box 1179 oy • ! Southold, New York 11971-0959 .fj�l �a0 Telephone (631) 765-1802 APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 10/14/2025 Company Name: DBA EmPower CES, LLC Electrician's Name: Timothy Crotty License No.: ME-65990 Elec. email: info@the-ec.com Elec. Phone No: 516-837-3459 ❑✓ 1 request an email copy of Certificate of Compliance Elec. Address.: 1000 Fulton Street, Farmingdale, NY 11735 JOB SITE INFORMATION (All Information Required) Name: John Nanas Address: 2205 Gillette Drive, East Marion, NY 11735 Cross Street: Phone No.: 917-400-4899 Bldg.Permit#: email:john.nanas@gmail.com Tax Map District: 1000 Section: 038.00 Block: 03.00 Lot: 014.000 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Installation of roof mounted solar panels (25) HYU--440w modules, 11.0kW total system size Square Footage: Circle All That Apply: Is job ready for inspection?: ElYES NO ❑Rough In ❑ Final Do you need a Temp Certificate?: W YES NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 F12 R H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION IDLAND PLACE R=25.00 L=39.27 0 0 o m o C\2 N 64051'10" E 81.51 C? o L6 M U-D .-i .. •�'� .37.4.' . z1.7 w w 29.6' I5.4 E.a I�+illlM•/ Iti� H, .y p.I�1.0 E0- W O N Lyy 1III o O .:. U] 2 Q o .a i=i c [� 5.a1 I II 11.0 .p C43 z 35.0Uu o^ a w O L 2 mcc C,2 M LO Z c'l N v� cn S 64051'10" W 83.22 of N E r �Q,'CP�.�N G.MrPGl Lu CERTIFIED TO: JOHN NANAS & VASIJM NANAS i REGAL TITLE AGENCY F` J� (TITLE No: RT-41906) F 0502 D LAND S�� WESTCOR LAND TITLE INSURANCE COMPANY SCALE: 1"=30' DRAWN BY: R.K.H. SURVEY OF LOT 37, FILE DATE �H 17, 2015 LISA MCQUILEIN 419-00 AS SHOWN ON MAP OF MARION MANOR + LAND SURVEYING FILED: MARCH 18, 1953 - MAP No: 2038 AT EAST MARION, TOWN OF SOUTHOLD, 274 EAST MAIN STREET SUFFOLK COUNTY, NEW YORK AREA: _11,118.50 Sq.Ft. EAST ISLIP, N.Y. 11730 SCTM: 1000-038,00-03.00-014.000 0.2552 ACRES TEL: 631-277-3606 FEMA FLOOD ZONE - X FAX: 631-277-3906 UNAUTNOB®ALTEEATION OR ADOffION 70 TN1S SURVEY LS A YIDUT[ON OF SECTTON 720D OF TILE NEF YDRE SLATE EDDCATION L1R,COPDiS OF TRL9 SURVEY DldP NOT BEARDVC THE L1ND SUP.yT:YORS U7h2D Ok E.MDUSSED SEAL AR8 NOi CONSU)ERED TO RE A TRUE VdI,ID COPY.DISTANCES SNONN F801f PROPERTY CINES TO EXLSf(NC STRUCTURES�FOR A SPECR�IC PURPOSE ANO USE,AND dRE NOT INtEYDEO TD GUIDfi Itr TILE EP.ECTION OF PENCES OR OT1�R SIRUCTUEFS.CERTR7CATION INDICTED R0tE0N SRAI,L RUN ONLY TO THE PERSON FOR AROM 7NE SURVEY LS PREPARED AND ON iDS DIDWF,TU TIffi COlSPdNYOR AGENCIES llS1ED REP.EON AND TO TILE AESICNEE$OF TR8 IENOING INSTITU710N.CERTlPICA7IONS ARE NOT TRANSPERARIE TO ADDITIDNAL IN'S17711TION5 OR SUDSEQUENT ONNERS. 2205 GILLETTE DRIVE, SOUTHOLD [EMPOWER S O L A R 1000 FULTON STREET ENCLOSURE FARMINGDALE,NY 11735 UTILITY TEL:516-837-3459 NEMA 311 METER FAX:516-706-1789 BRANCH BRANCH BRANCH t IM WWW.EMPOWER-SOLAR.COM (1)HiN-T440NF(BK) (12)HiN-T44ONF(BK) (12)HiN-T440NF(BK) TO MAIN TO THE INFORMATION DISCLOSED HERIN ISTHE SOLE (1)ENPHASE IQ8MC-72-M-US (12)ENPHASE IQ8MC-72-M-US (12)ENPHASE IQ8MC-72-M-US SERVICE UTILITY PROPERTY OF EMPOWER CES,LLG UNAUTHORIZED TOTAL DC STC POWER:0.44 kW TOTAL DC STC POWER:5.28 kW TOTAL DC STC POWER:5.28 kW PANEL GRID REPRODUCTION OR DISTRUSUTION OF THIS TOTAL AC POWER:0.32 kW TOTAL AC POWER:3.84 kW TOTAL AC POWER:3.84 kW A04 _ MATERIAL 15 STRICTLY PROHIBITED WITHOUT PRIOR CONTMUEAS CONTINUEAS CONTINUEAS REOUIREDFOR INV.... REQUIREDFOR INV.... REQUIREDFOR INV.... ENPHASE SPECIFIC WRITTEN PERMISSION. SPECIFIED STRINGING SPEQFIEDSTRINGING SPECIFIEDSTRINGING DATA PROFESSIONAL ENGINEER �ACI ACl —AC1 MONITORING AC DISCONNECT(EXTERIOR) 60A,2P CB L7 L2 N 11)HiW7UDNFIBYJ (I)HiN-T660NHBK) 1)MiN-TG40NF(BKI G D)ENPHASE MIMOINV. INV.2 (])ENPHASE MICRO INV. INV.2 S)ENPHASE MICRO INV. INV.2 2DA,2P CB AC] ACl ACI TI 20A,2P CB AC3 (I)HIN-TG40NF(B14 (1)HIN-TO<ONH111 (I)HIN-T6CDNF(814 20A,2P CB (11 ENPME MICRO INV. INV.] (])ENPHASE MICRD INV. INV.] (1)ENPHASE m1moINV. INV.1 20A,2P CB �ACl .—ACS �—AC1 PROFESSIONAL SEAL ,NYORK4 N��D MK 63 --i•• AC2 jl u • 2` OEN�IP.PENS` TO RACKING / G AC COMBINING MLO PANEL GROUND NEMA 3R 1-PHASE 120/240V PROJECT NAME: ENCLOSURE NAME RESIDENCE (1)k6 AWG,EGC LABEL DESCRIPTION LABEL DESCRIPTION SPR AC CABLE 1"PVC Act (2)#12 AWG AC2 (6)H10AWG PROJECT LOCATION: (1)#10 AWG,EGC 3/4"PVC 11/4"PVC 2205 Gillette Drive AC3 (3)#12 AWG AC4 (3)#6 AWG (1)012 AWG,EGC (1)#6 AWG,GEC East Marion,NY 11939 ACCOUNT#:9674063757 PROD.PHASE: PROPOSAL METER#:98385277 DATE: 10/10/2025 DESIGNED BY: SA CHECKED BY: GS SCALE: NTS NOTES: 1.NEUTRAL&GROUND ARE BONDED TOGETHER(ORIGIN OF GEC FOR SOLAR ELECTRIC SYSTEM) _ TITLE: 2.GEC FROM SOLAR ELECTRIC SYSTEM BONDED TO EXISTING GEC IN THE MAIN SERVICE PANEL USING IRREVERSIBLE SPLICE /� j ;( TOTAL SYSTEM SIZE:11 kW 3.USE TAP RULES FOR SIZING TAP CONDUCTORS(NEC 240.21) 4.SIZE GEC AND EGC AS PER NEC 240.66,NEC240.122 RESPECTIVELY F p v ^"' 4 �Vt L�- - (25)HiN-T440NF(BK) PV ELECTRICAL SYSTEM S.USE MC ONLY IF INCLUDED GEC IS ADEQUATELY SIZED. (25)ENPHASE IQ81VIC-72-M-US 3-LINE DIAGRAM "t I ( C I CUC� Gregory Sachs, PE 1000 Fulton Street 516-544-4592 Farmingdale, NY 11735 permitting@empower-solar.com October 13, 2025 To Whom It May Concern: The purpose of this letter is to certify that the existing roof structure located at: 2205 Gillette Drive, East Marion, NY 11939 can support the additional load of the solar energy system, in addition to wind,snow and gravity. Portions of roof structure covered and not covered with photovoltaic panels are in compliance with R324.4.1.1. Furthermore, it has been determined that the structure complies with the 2020 Residential Code of New York State including the ASCE 7. Please see Table 1 below for specific data relating to the calculations for each roof structure involved in the solar energy system installation. Table 1 Max Span Rafter Snow Wind Layers of Roof Surface (ft) spacing Cross Section Load Speed Kneewall Collar Ties Shingles (in) (psf) (mph) West 1 1 12.00 1 16 Nominal 2x8 20 135 No Yes 1 East 1 12.17 16 Nominal 2x8 20 135 No Yes 1 Sincerely, Gregory Sachs, PE �,TA'�ORif SAC o'� 2 o e ^h O /C,�NSF D DOFF 4 W FIYU N DA I eng.hd-hyundaies.co.kr D ENERGYSOLUTIONS FID FIYUNDAI SOLAR MODULE NF(BK) Series Premium N-Type TOPCon Module FliN-T430NF(BK) I FIiN-T435NF(BK) I FIiN-T440NF(BK) 4 22.53% I��II� T OR n M= . r 22.53% High-End Higher Long-Term Compatible For Residential High Efficiency TOPCon Bifaciality Reliability with Carport (Full Black Design) Technology Applications HD Flyundai's Warranty Provisions 0 HD HES TOPCon Module Certification 99% PERC Standard rJ 25-Year Product Warranty 1090% • �� M 0 WA vERs •Materials and workmanship 89.0 874% PVEL 0 90% • • �I50900":Quality ma•'ageme,,tsystms 30-Year Performance Warranty 85% r>r>v): :[Swrnnmcnlalmanax:rncrtsyslsms •IS[i�SJJ':rk;r:upatr:•ndl^c•;:Ilhan:tiali�C�/manal7cmE:n[sy.-.tans 3® First year degradation:1 80J° R fi77:ip,plroU+ :ILr.:(>V)••Eniule v+te yqualificalion iE-Al YEARS -Linear warrntyafter initial year. p , '10 15 20 25 30 IEt.°i/0,.";Il. tcs.inu with 0.4/p annual degradation, E[:Ei2ltti.Alnmun4lCGrr::Sk'.(E:(iR] 87.4 is guaranteed up to 30years �Rerer u)HD I iE5 standard•*arranty .ir derails. r-i2eo, 'a[erranndE d graaxa ntl iu,[enr.ng IEC 60068-2-65:Sarin and dus-[eeting fbi env1r,3,nen[aI durability 1 Electrical Characteristics BNP Nominal output(Pmax)Item UWt 430 '476I -� 435 4821 -� 440 4881 - Open circuit voltage(Voc) V 38.4 38_4 38.6 38.6 38.8 38.8 Short circuit current(Isc) A 14.25 15.79 14.32 15.87 14.39 15.94 Voltage at Pmax(Vmpp) V 31.9 31.9 32.1 321 32.3 32.3 - Current at Pmax(Impp) A 13.48 14.94 13.56 15.01 13.63 15.10 Module efficiency % 22.02 24.40 22.28 24.68 I 22.53 25.00 Power Class Sorting W - 0-+5 Temperature coefficient of Pmax %/K -0.30 Temperature coefficient of Voc %/K _-_ _ -0.25 _- Temperature coefficient of Isc %/K 0.046 - Bifaciality % 80%*10% 'STC:Irradiance 1.000 W/m',cell temperature 25°C,AM=1.5/Test uncertainty for Pmax±3/;Voc t3%;Isc±3% "The electrical properties of BNPI are measured under the irradiance corresponding to 1000 W/m'on the module front and'135 W/m'on the module rear. AdditionalPower Pmpp gain Pmpp[W] Vmpp[V] Impp[A] I VOC[V] Isc[A] 5% 458 32.30 14.18 38.80 14.97 15% 493 32.30 15.27 38.80 16.12 25% 528 32.40 16.36 38.90 17.27 'Electrical characteristics With different rear polver gain(reference to 440W) Mechanical Characteristics Installation Safety Guide Dimensions 1,722mm(L)x 1,134mm(W)x 30mm(FI) Only qualified personnel should install or perform (67.8in x 44.6in x 1.2in) maintenance. Weight 24.5 kg(50.01lbs) •Be aware of dangerous high DC voltage. Solar Cells N-Type TOPCon,108(6x18)monocrystalline 16BB half-cut bifacial cells Ca ble:(+)1,200mm(47.2in),(-)1,200mm(47.2in)/Customized length availa ble Do not handleorinstallmcduleswhentheyarewet. outputCabtes Con nector:StaubliMC4genuine Con rector/Compatible,IP68 Nominal Module Operation 44°C+2°C Junction Box 3-part,3 bypass diodes,IP68 rated Temperature Front:2.Omm(0.08in)semi-tempered solar glass with high transmittance Operating Temperature -40`C-+85°C Construction and anti-reflective coating Rear:2.Omm(O.08in)semi-tempered solar glass Maximum System Voltage DC 1,500 V Frame Anodized aluminum alloy Maximum Reverse Current 30A Maximum Test Load Front 5,40OPa 'See Installation Manual *Rear5,40OPa Shipping Configurations Fire Performance Type29 Packing Direction Vertical Packing pallet weight(kg) 912 Container Size(FIC) 40' Modules Per Pallet(PCs) 36 Pallets Per Container 26 Modules Per Container(pcs) I 936 Module Diagram(unit:mm) I-V Curves(HIN-T44ONF(BK)) Current[A] 30s 1mm/ Berwdel 1.18s00d 16 BerCOae ' tyfiy 14 12 III I 6' G�Fda E 4-0-1 10 - 0.16' I III Bar, 2 8 GrouMirrgg Jun tla B x mark 32mm:^6' 6 -Operating Cell Temp=5°C 1z i 4 -operating Cell Temp=25°C Vv tng -operating Cell Temp=45°C 9-14x9rtm! A-A 2 Operating Cell Temp WC 0,55W.3-' Vo+.uP•'. 0 E E € 0 10 20 30 40 s a Voltage IV] V_ Current[A] 16 14 �I IIIII 12 -Irradiance-1,000W/m 0ra�ho�aE, I8mm0.71' 10 -Irradiance=80ow/m' D-me 0.3..12' 8 n 12.1 -Irradiance=600W/m' I D-0 6 L_ 4 -Irradiance=400W/m' 1088t2 4284:0.08• B 1134-2 44.65!0.0a' 2 -Irradiance=200W/m' 0 0 10 20 30 40 FRONT SIDE REAR Voltage[V] Sales&Marketing .D Hyundai Energy Solutions reserves the right to update or modify the specifications and features listed in this datasheet HYUNDAI hes.sales@hd.com ,. Without pr HD ior notice.Always check the latest version of thedatasheetforaccurateinformation.Beforeusingtheproduct, ENERGYSOLUTIONS crease refer to the Installation and operation Manual and warranty.We retain the right of final interpretation. ENPHASE. 7w i 4'abpp i m IQ8MC Microinverter Easy to instal I Lightweight and compact with plug-and-play Our newest IQ8 Series Microinverters are the industry's first microgrid-forming',software- connectors defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary Power line communication(PLC)between application-specific integrated circuit(ASIC),which enables the microinverter to operate in components grid-tied or off-grid modes.This chip is built in advanced 55-nm technology with high-speed Faster installation with simple two-wire digital logic and has superfast response times to changing loads and grid events,alleviating cabling constraints on battery sizing for home energy systems. High productivity and reliability Produces power even when the grid is down' Enphase 25 More than one million cumulative hours of testing yea,limited Class II double-insulated enclosure Optimized for the latest high-powered PV Part of the Enphase Energy System, I08 Series Microinverters redefine modules IQ8 Series Microinverters integrate with reliability standards with more than one the IQ Battery,IQ Gateway,and the million cumulative hours of power-on Enphase App monitoring and analysis testing,enabling an industry-leading Microgrid-forming software. limited warranty of up to 25 years. • Complies with the latest advanced grid support �• Remote automatic updates for the latest grid j requirements CERTIFIED Configurable to support a wide range of grid SArm profiles Meets CA Rule 21(UL 1741-SA)and Connect PV modules quickly and easily IQ8 Series Microinverters are UL Listed IEEE1547:2018(UL 1741-SB) to the IQ8 Series Microinverters that have as PV rapid shutdown equipment and integrated MC4 connectors. conforms with various regulations when NOTE: installed according to the manufacturer's instructions. IQ8 Microinverters cannot be mixed together with previous generations of Enphase microinverters (I07 Series,I06 Series,and so on)in the same system. • IQ Microinverters ship with default settings that meet North America's IEEE 1547 interconnection standard requirements.Region-specific adjustments may be requested by an Authority Having Jurisdiction(AHJ)or utility representative. *Meets UL 1741 only when installed with IQ System Controller 2 or 3. An IQ Gateway is required to make these changes during Installation. ©2024 Enphase Energy.All rights reserved.Enphase,the a and CC logos,IQ and certain other marks listed at h"ps://enphase.com/trademark-usage-quidelines are trademarks of Enphase Energy,Inc.in the U.S.and other countries. IQ8MC-MC4-DSH-00049-4.0-EN-US-2024-02-09 Data subject to change. IQBMC Microinverter INPUT DATA JD�l UNITS r: Commonly used module pairings W 260-460 Module compatibility _ To meet compatibility,PV modules must be within the following max.input DC voltage and max.module I,,. Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator. MPPT voltage range V 25-45 Operating range V 18-58 Min./Max.start voltage V 22/58 Max.input DC voltage V 60 Max.continuous operating DC current A 14 Max.input DC short-circuit current A 25 Max.module I,, A 20 Overvoltage class DC port — II DC port backfeed current mA 0 PV array configuration — Ungrounded array;no additional DC side protection required;AC side protection requires max 20 A per branch circuit OUTPUT DATA r: r VAC 108MG-72-M-USr:VAC Peak output power VA 330 315 Max.continuous output power VA 320 310 Nominal grid voltage(L-L) V 240,split-phase(L-L),180° 208,single-phase(L-L),120° Min./Max.grid voltage 2 V 211-264 183-229 Max.continuous output current A 1.33 1.49 Nominal frequency Hz 60 Extended frequency range Hz 47-68 AC short circuit fault current over three Arms 2.70 cycles Max.units per 20 A(L-L)branch circuit' — 12 10 Total harmonic distortion % <5 Overvoltage class AC port — III AC port backfeed current mA 18 Power factor setting — 1.0 Grid-tied power factor(adjustable) — 0.85 leading...0.85lagging Peak efficiency % 97.4 97.2 CEC weighted efficiency % 97.0 96.5 Nighttime power consumption mw 33 25 MECHANICAL DATA Ambient temperature range -40°C to 65°C(-40°F to 149T) Relative humidity range 4%to 100%(condensing) DC connector type Staubli MC4 Dimensions(H•W•D);Weight 212 mm MY)•175 mm(6.9")x 30.2 mm 0.2");1.1 kg(2.43 Ibs) Cooling Natural convection-no fans Approved for wet locations;Pollution degree Yes;PD3 Enclosure Class II double-insulated,corrosion-resistant polymeric enclosure Environ.category;UV exposure rating NEMA Type 6;outdoor COMPLIANCE CA Rule 21(UL1741-SA),UL 62109-1,IEEE 1547:2018(UL 1741-SB),FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01. Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017,NEC 2020,and NEC 2023 section 690.12 and C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's instructions. (1)No enforced DC/AC ratio. (2)Nominal voltage range can be extended beyond nominal if required by the utility. (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQBMC-MC4-DSH-00049-4.0-EN-US-2024-02-09 Revision history REVISION i DSH-00049-4.0 February 2024 Added information about IEEE 1547 interconnection standard requirements. DSH-00049-3.0 October 2023 Included NEC 2023 specification in the"Compliance'section. DSH-00049-2.0 September 2023 Updated module compatibility information. DSH-00049-1.0 May 2023 Preliminary release. ©2024 Enphase Energy.All rights reserved.Enphase,the a and CC logos,IQ,and certain other marks listed at httos://enphase.com/trademark-usage-quidelines are trademarks of Enphase Energy,Inc.in the U.S.and other countries. Data subject to change. IQ8MC-MC4-DSH-00049-4.0-EN-US-2024-02-09 UP ,V6. z.. ," <� '{ - e..,*a f'✓ �'``"". E'a to er EROt ZI k G .. r Racks �icceleraedl s. \` Aires is a care uNy�engtnebjrr6ds, erkgogQrnrc racking systemXor pitched roofs harioringhoth speed arrd recision. Each cbry ponent has been desrgned fo en otce a quality lnstal[atian that can witstar►d=t ements, V1fe've,worked hand4n-gic�trer�trith"instaltars ta:prornde.fhe strongest, feature rich, open chahnel tall an the rnarke : p Two rall,;sizes m coe in black-ana med and millf nkshes Listed to UL 2703.and•backed by a 25=year warranty. e Fu[ly Certifred(able l ayf 'One Tool 1/2"System t=, cable tray tVises c o npliarit Xaq% 'Wft Ne�VlA /�lre LC2G C S$rgree stanamg Aw �' '�` t-f E ". >'' "s'. .`�+. s f• ,,r. 7ecinoCdgea pr�eitie T � , campso'•a eke�res�u��t�e�t� _ �� < TMI CDR! Am `"*` �kie�at `�n Y p�ov e c can>aesthe Ces �k _ ,, � a .• a ee- . e- s Ail Aire® Flush Mount System Racking Accelerated° ; Y Two Optimized Aire® Rail Sizes Internal Bonded Structural Splices Al Rail meets most load conditions, while the heftier Aire"'Ties connect two pieces of rail together without A2 Rail is best in heavy-snow and high-wind regions. penetrations. Its water-relief "bridge" allows drainage. Easy Hardware &Wire Placement Aesthetically-Pleasing Hidden Ends Quarter turn and Aire Lock°clamps stand freely. Wire Aire Lock®Stealth clamps module row ends. With a Clips press in, with a flat-head slot for quick removal. 150 angled bolt, rail cuts are not needed for access. Rail Selection The provided table* illustrates span 120 differences for Aire®Al and A2 Rails. It was prepared in compliance with None 150 applicable codes and standards. iso Al jA2 150 20 Values based on the following 180 i criteria:ASCE 7-16, Gable Roof 150 Mobile Resources Flush Mount, Roof Zones 1 & 2e, 30 iso I 10. ❑� Exposure B, Roof Slope of 80 to 200 40 180 I "� and Mean Building Height of 30 ft. 80 180 �r Visit IronRidge.com for detailed 120 180 certification letters. `Table is for illustration purposes only.Use approved certification letters for actual design guidance. y°}...' 9 i�^R� �P ;.-^ �a�. .9 1 JS h 1 2 1 3 1 4 5 6 1 81 9 10 11 1 12 13 - EMPOWER SOL ,& R 1000 FULTON STREET FARMINGDALE,NY 11735 c. ^' TEL: 516-837-3459 RESIDENCE FAX:pow-r-6-1789 �11 - I www.empower-solar.com H SOLAR PROJECT THE INFORMATION DISCLOSED HEREIN IS THE SOLE H PROPERTY OF EMPOWER CES,LLC.UNAUTHORIZED REPRODUCTION OR DISTRIBUTION OF THIS PROJECT TEAM: MATERIAL IS STRICTLY PROHIBITED WITHOUT PRIOR SPECIFIC WRITTEN PERMISSION C C UPAN CY 0 RY PROFESSIONAL SEAL APPROVED AS NOTED ¢ iE IS UNLAWFULs; OWNER: John Nanas G : DATE• ®• •a�B.P.# a � �Y ORtt� x ITHOUT CERTIFICATE G sAP FEE 99"•0'%Y: _ o.._`'fir„ c� NOTIFY BUILDING DEPARTMENT AT OCCUPANCY xw}u W - •01:' 631 765-1802 8AM TO 4PM FOR THE FOLLOWING INSPECTIONS: PHONE: 9174004899 +: 1. FOUNDATION-TWO REQUIRED ENGINEER OF RECORD: F F FOR POURED CONCRETE o � -- -" — SOLAR INSTALLER: GREGORY SACHS, PE �cF oF� 2. ROUGH—FRAMING&PLUMBING COMPLY WITH ALA.CODES F EMPOWER SOLAR NSF & INSULATION NEW YORK STATE&TOWN CODES FARO FULTON STREET 1000 FULTON STREET FARMINGDALE, NY 11735 4. FINAL-CONSTRUCTION MUST AS REQUIREP AWCONDMO14S OF FARMINGDALE, NY 11735 BE COMPLETE FOR C.O. � AR' PHONE: 516-837-3459 E ALL CONSTRUCTION SHALL MEET THE GBzm PHONE: 516-837-3459 E REQUIREMENTS�OFTHE CODESOF NEW on YORK STATE. NOT�RESPONSIBLE FOR z Q(��Q�'iQWNjR ES DESIGN OR CONSTRUC ON ERRORS "" V OEC SOUDw HPC D REV: DESCRIPTION: DATE: D t` PROJECT DATA: SHEET INDEX: PROJECT NAME: ELECTRICAL TNSPECJIPN REQUIRED RETAIN STORM WATER RUNOFF John Nanas ADDRESS:2205 Gillette Drive, East ST-01 COVER SHEET � \ PURSUANT TO CHAPTER 236 Marion, NY 11939 S-01 SITE PLAN PROJECT LOCATION: S-02 STRUCTURAL OF THE TOWN CODE. 2205 Gillette Drive, East c SE-01 ELECTRICAL c 2.o Marion, NY 11939 1000-038.00-03.00-014.000 PROJECT#: X PROJ.PHASE: PERMIT a ` DATE: 10/13/2025 B �° \ B DESIGNED BY: ED CHECKED BY: GS SCALE: NTS MAP TITLE: COVER SHEET A A SHEET: ST-01 1 1 2 1 3 1 4 1 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER S O L A R 1000 FULTON STREET FARMINGDALE,NY 11735 0 TELEPHONE:516-3 - PERMITTING:516-544-4592 www.empower-soIar.com THE INFORMATION DISCLOSED HEREIN IS THE SOLE H H PROPERTY OF EMPOWER CES,LLC.UNAUTHORIZED REPRODUCTION OR DISTRIBUTION OF THIS MATERIAL IS STRICTLY PROHIBITED WITHOUT PRIOR SPECIFIC WRITTEN PERMISSION WEST-1 ROOF: PROFESSIONAL SEAL 3 11 HYU-440W AC PV PANELS DRIVEWAY TOTAL POWER:4.84 0; IT ORIENTATION: 23232 PITCH:28° G TYPE 1: HUG MOUNT G ��Y O Rk SOLAR ACCESS: 94°/D SAC TSRF: 84% 4 O 1 EAST-1 ROOF: o W y 41* * 3 14 HYU-440W AC PV PANELS r- z F TOTAL POWER:6.16 kW F 'r�ph�' �� ORIENTATION:520; PITCH: 26° TYPE 1: HUG MOUNT cFNSEp�ti��F SOLAR ACCESS: 93% n EQUIPMENT LEGEND: TSRF: 61°/D E MODULES E r' UTILITY METER SETBACK LEGEND rn 36" CLEAR PATH D 1 ❑3 INVERTERS D REV: DESCRIPTION: DATE: ® 18" RIDGE SETBACK PROJECT NAME: T 4❑ SOLAR DISCONNECT Ji ' ' I NANAS RESIDENCE ® ACCESS ROOF ® PROJECT LOCATION: MAIN SERVICE PANEL C C 2205 GILLETTE DRIVE T EAST MARION,NY 11939 / PROJECT#: > PROJ.PHASE: PERMIT DATE: 1 0/1 312 02 5 B 5 B DESIGNED BY: ED CHECKED BY: GS ,L SCALE: NTS TITLE: 4 SITE PLAN A ROOF LAYOUT A NOT TO SCALE SHEET: S-01 1 2 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 6 9 10 11 12 13 EMPOWER - S O L A R 1000FULTON STREET SUNPOWER MODULES FARMINGDALE,NY 11735 ON INVISIMOUNT RACKING TEL: 516-837-3459 SHINGLES FAX: 516-706-1789 www.empower-soIar.DOm THE INFORMATION DISCLOSED HEREIN IS THE SOLE H H PROPERTY OF EMPOWER CES,LLC.UNAUTHORIZED RAFTERS REPRODUCTION OR DISTRIBUTION OF THIS MATERIAL IS STRICTLY PROHIBITED WITHOUT PRIOR SPECIFIC WRITTEN PERMISSION PROFESSIONAL SEAL G G O R K alFd k� SAC a 2� (9 ,....: F F TYPICAL ROOF SECTION NOT TO SCALE cF'�sF r r�o4 . PANELSPECS E MODULE POWER (Wdc) QTY MODEL# LENGTH WIDTH DEPTH WEIGHT TABLE S-1.1: MAX.ATTACHMENT SPACING E HYU-440 25 SPR-M-SERIES-AC 73.7" 40.6" 1.57" 48.0 LB PORTRAIT: 5'-4" LANDSCAPE: 8'-0" SPR-X-SERIES-AC 61.4" 41.2" 1.811, 42.9 LB HYU-SERIES-DC 67.8" 44.6" 1.20" 50.01 LB D NOTES: D REV: DESCRIPTION: DATE: 1. TOTAL SYSTEM DC POWER:11.00 kW 2. RACKING SYSTEM INSTALLED IN ACCORDANCE WITH CODE-COMPLIANT INSTALLATION PROJECT NAME: MANUAL John Nanas 3.ATTACHMENTS TO BE SECURED TO ROOF ASSEMBLY USING 5 mm STAINLESS STEEL SCREWS AND/OR 5/16"STAINLESS STEEL LAG BOLTS SPACED ACCORDING TO TABLE S-1.1 PROJECT LOCATION: 4. ALL ATTACHMENTS TO ROOF, MOUNTING BRACKETS & HARDWARE MEET OR EXCEED NYS 2205 Gillette Drive, East C CODE REQUIREMENTS C Marion, NY 11939 5. INSTALLATION TYPICALLY MAINTAINS 7/8 INCH SPACING BETWEEN MODULES 6. SIZES OF STRUCTURAL MEMBERS THAT WERE NOT ACCESSIBLE FOR DIRECT MEASUREMENT ARE BASED ON OBSERVATIONS OF ACCESSIBLE MEMBERS, CONSTRUCTION DEPTH OR PROJECT#: BOTH IN ADDITION TO KNOWLEDGE OF STANDARD CONSTRUCTION PRACTICES AT THE PROJ.PHASE: PERMIT TIME OF CONSTRUCTION DATE: 10/13/2025 B 7. THIS DOCUMENT CERTIFIES THAT THE ROOF STRUCTURE HAS BEEN CHECKED FOR WIND, B DESIGNED BY: ED SNOW, UNBALANCED SNOW, LIVE AND DEAD LOADS BASED ON ASCE 7-10 CHAPTER 30 - CHECKED BY: Gs WIND LOADS - COMPONENTS AND CLADDING (C&C) AND FOR CONFORMANCE WITH THE SCALE: NTS 2020 RESIDENTIAL CODE OF NEW YORK STATE. THIS CERTIFICATION DOES NOT APPLY TO TITLE: ANY ADDITIONAL ROOF ALTERATIONS AFTER THE DESCRIBED INSTALLATION STRUCTURAL 8. THIS ROOF STRUCTURE AS SHOWN IS ADEQUATE TO SUPPORT THE PROPOSED LOADS A 9. REFER TO STRUCTURAL LETTER FOR SITE SPECIFIC AND ROOF SURFACE DATA rA SHEET: S-02 1 2 3 4 5 6 7 j 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 , EMPOWER NOTES: , S o L w R 1000 FULTON STREET FARMINGDALE,NY 11735 1. NEUTRAL&GROUND ARE BONDED TOGETHER (ORIGIN OF GEC FOR SOLAR TEL: 516-837-3459 ELECTRIC SYSTEM) FAX: 516-706-1789 2. GEC FROM SOLAR ELECTRIC SYSTEM BONDED TO EXISTING GEC IN THE MAIN www.empower-solar.com STANDARD INVERTER ASSEMBLY: SERVICE PANEL USING 'SPLIT-BOLT CONNECTOR' THE IDISCLOSED HEREIN IS THE SOLE H 3. IN SOME CASES POWER FOR DATA MONITORING ENCLOSURE MAYBE H PROPERTY OFTION EMPOWER CES,U.C.UNAUTHORIZED DERIVED FROM MAIN SERVICE PANEL REPRODUCTION OR DISTRIBUTION THIS MATERIAL IS STRICTLY PROHIBITED WITHOUT HOUT PRIOR SPECIFIC WRITTEN PERMISSION 4. CONNECT UTILITY SIDE TO PANEL LUGS PROFESSIONAL SEAL 5. USE TAP RULES FOR SIZING TAP CONDUCTORS (NEC 240.21) 6. SIZE GEC AND EGC AS PER NEC 250.66, NEC 250.122 RESPECTIVELY — — 7. PROTECT GEC AND EGC SUBJECT TO PHYSICAL DAMAGE AS PER NEC G SOLAR 1 250.64(B), NEC 250.120(C) G Y ORK ARRAY ��10 SAC o <__ k INVERTER(S) AC 0 DISCONNECT cr k. F F O /CFN S F n P Ci0 E E STANDARD EXTERIOR INTERCONNECTION: STANDARD INTERIOR INTERCONNECTION: D D REV: DESCRIPTION: DATE: PROJECT NAME: INTERIOR EXTERIOR INTERIOR EXTERIOR John Nanas PROJECT LOCATION: c c 2205 Gillette Drive, East MAIN MAIN Marion, NY 11939 SERVICE TAP O 1 BREAKER SERVICE M PANEL ENCLOSURE PANELETTE PANEL PROJECT#: UTILITY UTILITY PROJ.PHASE: PERMIT METER METER DATE: 10/13/2025 B B DESIGNED BY: ED 1 CHECKED BY: GS SCALE: NTS TITLE: ELECTRICAL A A SHEET: S E-01 1 2 3 4 5 6 7 8 9 10 11 12 13 EMPOWER S O L A R 1000 FULTON STREET ENCLOSURE FARMINGDALE, NY 11735 UTILITY TEL:516-837-3459 NEMA 311 METER FAX:516-706-1789 BRANCH C BRANCH B BRANCH A i M WWW.EMPOWER-SOLAR.CCI'M (1)HiN-T440NF(BK) (12)HiN-T44ONF(BK) (12)HiN-T440NF(BK) TO MAIN TO THE INFORMATION DISCLOSED HERIN IS THE SOLE (1)ENPHASE IQ8MC-72-M-US (12)ENPHASE IQ8MC-72-M-U5 (12)ENPHASE IQ8MC-72-M-US SERVICE UTILITY PROPERTY OF EMPOWER CES,LLC.UNAUTHORIZED TOTAL DC STC POWER:0.44 kW TOTAL DC STC POWER:5.28 kW TOTAL DC STC POWER:5.28 kW PANEL GRID REPRODUCTION OR DISTRUBUTION OF THIS TOTAL AC POWER:0.32kW TOTAL AC POWER:3.84kW TOTAL AC POWER:3.84kW AC4 __ MATERIAL IS STRICTLY PROHIBITED WITHOUT PRIOR CONTINUEAS CONTINUEAS CONTINUEAS SPECIFIC WRITTEN PERMISSION. REQUIRED FOR INV.... REQUIRED FOR INV.... REQUIRED FOR INV.... ENPHASE SPECIFIED STRINGING SPECIFIED STRINGING SPECIFIED STRINGING DATA PROFESSIONAL ENGINEER MONITORING .� AC DISCONNECT(EXTERIOR) —AC1 --.AC1 —ACl 60A,2P CB L1 L2 N (1)HIN-T44ONF(BK) (1J HiN-T440N%BK) (1)HiN-T44ONF(BK) (, (1)ENPHASE MICRO INV. INV.2 (1)ENPHASE MICRO INV. INV.2 (1)ENPHASE MICRO INV. INV. 20A,2P CB 20A,2P CB , _-AC1 AC1 -ACl A13 A— Y-7 20A,2P CB(1)HIN-T440NF(BK) (1)HiN-T44ONF(BK) INV.1 (1)HIN-T44ONFIBK) (1)ENPHASE MICRO INV. INV.1 (1J ENPHASE MICRO INV. (1)ENPHASE MICRO INV. INV.1 20A,2P CB PROFESSIONAL SEAL -ACl �ACl T ACI 0 k k�A SAC O W Ora, � u D 121F` � .�••oe,`'�5 ,c' FF. FNSFDrKo TO RACKING G AC COMBINING MLO PANEL PROJECT NAME: GROUND NEMA 3R 1-PHASE 120/240V ENCLOSURE NAME RESIDENCE (1)#6 AWG,EGC LABEL DESCRIPTION LABEL DESCRIPTION SPR AC CABLE 1"PVC AC1 (z)a12AWG Acz (6)#10AWG PROJECT LOCATION: (1)#10 AWG,EGC 3/4"PVC 11/4"PVC 2205 Gillette Drive AC3 (3)#12 AWG AC4 (3)#6 AWG (1)#12 AWG,EGC (1)#6 AWG,GEC East Marion, NY 11939 ACCOUNT#: 9674063757 PROJ.PHASE: PROPOSAL METER#: 98385277 DATE: 10/10/2025 DESIGNED BY: SA CHECKED BY: GS SCALE: NTS NOTES: 1.NEUTRAL&GROUND ARE BONDED TOGETHER(ORIGIN OF GEC FOR SOLAR ELECTRIC SYSTEM) TITLE: 2.GEC FROM SOLAR ELECTRIC SYSTEM BONDED TO EXISTING GEC IN THE MAIN SERVICE PANEL USING IRREVERSIBLE SPLICE TOTAL SYSTEM SIZE:11 kW 3.USE TAP RULES FOR SIZING TAP CONDUCTORS(NEC 240.21) PV ELECTRICAL SYSTEM 4.SIZE GEC AND EGC AS PER NEC 240.66,NEC240.122 RESPECTIVELY (2S) HIN-T44ONF(BK) 5.USE MC ONLY IF INCLUDED GEC IS ADEQUATELY SIZED. (25) ENPHASE IQ8MC-72-M-US 3-LINE DIAGRAM