Loading...
HomeMy WebLinkAbout52424-Z ho�a°f souTyo`o Town of Southold * * P.O. Box 1179 53095 Main Rd UM�� Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46766 Date: 01/07/2026 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1400 Lighthouse Rd Southold, NY 11971 Seca lock/Lot: 50.-5-3 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 10/03/2025 Pursuant to which Building Permit No. 52424 and dated: 10/31,/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof mount solar to existing single family dwelling as applied for. The certificate is issued to: Karen Karp , Christiaan Batten Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 114985 12/16/2025 PLUMBERS CERTIFICATION: ALonWd Signatur ofsouryo�o TOWN OF SOUTHOLD BUILDING DEPARTMENT • �� SOUTHOLD, NY o`rCC NTI.Nc� . BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52424 Date: 10/31/2025 Permission is hereby granted to: Karen Karp PO BOX 515 Southold, NY 11971 To: Install roof mount solar to existing single family dwelling as applied for. Disconnects must be located on the exterior, labeled,and readily accessible. Premises Located at: 1400 Lighthouse Rd,Southold, NY 11971 SCTM#50.-S-3 Pursuant to application dated 10/03/2025 and approved by the Building Inspector. To expire on 10/31/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 CO-RESIDENTIAL $100.00 Total 200.00 Building Inspector NASSAU E L E C T R I C A DEC 26 2025 SUFFOLK INSPECTORS 159 Route 25A, Building 1 Suite B Miller Place, NY 11764 Telephone:631 495 8136 • Fax:631 509 4538 • E-Mail: Requests@SuffolkBEI.com CERTIFICATE OF ELECTRICAL COMPLIANCE Applicant: Venture Home Solar Certificate No.: 114985 Rough In Inspection Date: Final Inspection Date: Dec 16,2025 Application No.: Building Permit No.: 52424 County Tax Map No.: 500 3000 This Certificate of Electrical Compliance is limited to the inspection and compliance of electrical equipment and/or work described I below, installed on behalf of the applicant named above, located at the premise of and not after the final inspection date above: I Owner: Karen Karp Site Location: 1400 Lighthouse Road,Southold, NY 11971 Owner's Address(if different): Residential Indoor ❑Basement ❑Service ❑Shed Commercial Outdoor ❑First Floor ❑Pool ❑Hottub ❑New Renovation ❑Second Floor ❑Attic/3rd Floor ❑Garage ❑Addition ❑Survey PV Solar ❑Generator ❑Conversion ❑Signs ❑Battery Storage Other: INVENTORY Single Phase Heat O Duplex RecptO Ceiling Fixture Dual Func Breaker0 Three Phase Hot Water GFCI Recpt� Wall Fixture Smoke 0 on � Single RecptMain Panel ACCO Recessed Fixture CO Detect0 Sub Panel AC Blower Range Recpt LED Lighting Smoke CO Combo Transformer ApplianceCktO DryerRecpt� Emergency Time Clock Disconnect 0 Switches 0 Twist Lock Exit Fixtures Pumps GFCIBreaker0 Heat Pump Electric Heat PoolLuminaire0 Exhaust Fan Other Equipment:System Size:5.720 kW Qty:13 Desc:JA Solar:JAM54D41 440/MB Qty:13 Desc:IQ8MC-72-M-US(240V) The electrical work and/or equipment described above were inspected and was found to be in compliance with local, state and national electrical code requirements and this office. Applicant: Venture Home Solar License No.: 60556 Date Printed: Dec 16, 2025 Inspected I Signature: ��OF 50UryO �o �o job # TOWN OF SOUTHOLD BUILDING DEPT. o to, 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: ;0le- DATE INSPECTOR [ � ' - ' — - - — ~r_ -- � �� � ] /— � `> � � ' ' 12/32/2025 JJ \ Town ofSouthold — 54375 New York 2S DEC � 6 ?0�� ~ � ^^ � Southold, NY 11971 _ Re: |n�aUadonCer�fcatonLe�eJB����mq^0��mr��n��� ' ^ Certification ' To whom it may concern, The roof mounted photovoltaic system for the residence located at 1400 Lighthouse Road,Southold, New York 11971, has been generally observed to be installed properly in accordance with the approved plans and manufacturers specifications, and 1, Patrick Bussett, certify the solar panels to be in compliance with the minimum requirements of the town,the 2020 Residential Code of New York State,the 2018 International Residential Code (IRC),the National Electric Code of 2017,the provisions of ASCE 7-16, and all local governing county and municipal ordinances adopted by reference or enacted bylaw. Permit 52424 OF NEPI Best, 105278 SS Patrick Bussett, PE Emai|: pathck6usset1@ventuveso|ar.com FIELD INSPECTION REPORT DATE COMMENTS t� FOUNDATION (1ST) -- .L � ------------------------------------- FOUNDATION (2ND) [� .^ z �o 0 o cn ROUGH FRAMING& y }1 PLUMBING O S d � r1 V 1 r INSULATION PER N.Y. y STATE ENERGY CODE n•o?lv L V FINAL ADDITIONAL COMMENTS I -3 2 (� 0 AZ � ;7j ` k o � w � � z x x e r� b H '4� FF0(,ta TOWN OF SOUTHOLD—BUILDING DEPARTMENT N Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax (631) 765-9502 https:Hwww.southoldtownny.gov Date Received i APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector: �•,' �� Applications and forms must be filled out in their entirety.Incomplete � `•k c}�U��' applications will not be accepted. Where the Applicant is not the owner,an �•��at� t y Owner's Authorization form(Page 2)shall be completed: Date:10/2/25 OWNER(S)OF PROPERTY: 6 i Name:Karen Karp SCTM#1000-050000500003000 Project Address: 1400 Lighthouse Road, Southold, New York 11971 Phone#:(917) 327-9941 Email:karen@kkandp.com Mailing Address:1400 Lighthouse Road, Southold, New York 11971 CONTACT PERSON:; Name: Jared Landsman- Permit Coordinator Mailing Address:100 Charlotte Ave. Hicksville NY 11801 Phone#:516-234-9991 Email:permittingny@venturesolar.com DESIGN PROFESSIONAL INFORMATION: Name:Patrick.Busset Mailing Address:100 Charlotte Ave. Hicksville NY 11801 Phone#:516-234-9991 Email:permittingny@venturesolar.com CONTRACTOR INFORMATION: Name:Venture Home Solar LLC -Alex Yackery Mailing Address:100 Charlotte Ave. Hicksville NY 11801 Phone#:516-234-9991 Email:permittingny@venturesolar.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ®Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $$18,867.00 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes RNo 1 .; PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes El No IF YES, PROVIDE A COPY. B Check Box After Reading: The owner/contractor/design professional Is responsiblefor all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or.demolition as herein.described.The applicant agrees,to complywithall applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in buildings)for,necessary inspections.'False statement's made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New•YorkState Penal Law. Application Submitted By(prin ame):Ale Yackery BAuthorized Agent ❑Owner Signature of Applicant- Date: 10/2/25 STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Alex Yackery being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the Contractor- Venture Home Solar LLC (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 2nd dav of October 25 STEPHEN JOHN LUISE JR tar u b l i c NOTARY PUBLIC,STATE OF NEW YORK Registration No.02LU6407287 Qualified in SUM" " PROPER Y OWNER AUTHORIZATION My Comtnission Expires _12 the applicant is not the owner) Karen Karp residing at 1400 Lighthouse Road, Southold I, New York 11971 Alex Yackery-Venture Home solar do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Z. 10/2/25 wn is Signature Date Karen Karp Print Owner's Name 2 Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) I, KA L&&-? residing at &0o (.ZRMT biz Ra" -50 744Mt�,/J llC(gI (Print property owner's name) (Mailing Address) do hereby authorize Alex Yackery-Venture Home Solar (Agent) to apply on my behalf to the Southold Building Department. 10- -2oZs (Owner' Sign re) (Date) KaR,10 �4lZi� (Print Owner's Name) oy�S�FFat�.cOG BUILDING DEPARTMENT- Electrical Inspector �� y.► TOWN OF SOUTHOLD o '` Town Hall Annex- 54375 Main Road - PO Box 1179 _ Southold, New York 11971-0959 yIj O� Telephone (631) 765-1802 - FAX (631) 765-9502 �l �a rogerrftsoutholdtownny.gov— seand@southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 10/2/25 Company Name: Venture Home Solar LLC Electrician's Name: Jason P. Sampogna License No.: ME-60556 Elec. email: permittingny@venturesolar.com Elec. Phone No: 516-234-9991 ❑I request an email copy of Certificate of Compliance Elec. Address.: 100 Charlotte Ave Hicksville, NY 11801 JOB SITE INFORMATION (All Information Required) Name: Karen Karp Address: 1400 Lighthouse Road, Southold, New York 11971 Cross Street: Soundview Ave Phone No.: (917)327-9941 Bldg.Permit#: Sa qa Cf email: karen@kkandp.com Tax Map District: 1000 Section:5 Block: 5 Lot: 3 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): PV ROOF-MOUNTED SOLAR INSTALLATION 13 PANELS 13 MICROINVERTERS 5.720 kW TOTAL ARRAY AREA 273.25 SQ FT Square Footage: 1 273.25 SQ FT Circle All That Apply: Is job ready for inspection?: ElYES ❑NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑✓ Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION venture soiar 9/26/2025 Karen Karp 1400 Lighthouse Road Southold, New York,11971 Re:Solar Panel Installation To Whom It May Concern, At your request, Patrick Bussett of Venture Solar LLC(NY license#105278),has carefully reviewed the existing roof framing and the proposed connection of the panels to the roof for the building referenced above. The following building codes were used in conjunction with the 2020 Residential Code of New York State to generate pertinent design criteria: ASCE 7-16—Minimum Design Loads for Buildings and Other Structures National Design Specification for Wood Construction 2018 Edition(NDS) Design Criteria Design Gravity Load: Snow/Live Load=25 Ibs/ft2, Dead Load=12 psf Design Wind Load: Vult=127 mph; Exposure B Risk Category II *Wind loads exceed seismic loads and therefore govern the design Field observations identified the following conditions: The new solar panels will impose an additional dead load of approximately 3 psf.The roof consists of asphalt shingles over plywood sheathing supported by 2x8 rafters at 24"o.c.The rafters are sloped at a 36°pitch and have a maximum projected horizontal span of 9'-O"(±).The framing is assumed to be Douglas Fir#2 graded or better. The calculations determined that the existing framing has adequate capacity to support the PV panels as shown in our PV panel layout plan with no structural upgrades required.I therefore certify that this installation complies with the applicable codes and is acceptable for approval.Please feel free to contact me if you have any questions or concerns. Best, �P��,0F N£yrY, Sao �,o Z I a to ti 105278 Patrick Bussett, PE FAA Email:patrick.bussett@venturesolar.com S510�Q' Expiration:4/30/2027 PLAN SET LEGENDS AND ABBREVIATION SCOPE OF WORK GOVERNING CODES ��-Bf Nfwr (E) EXISTING SYSTEM SIZE: 5.72 KW DC,4.16 KW AC NEW YORK STATE ELECTRICAL CODE 2017 VICINITY MAP(SCALE: NTS) �� �K BUSSF��p� (N) NEW MODULE: 13 JA Solar Technology:JAM54D41-4401MB NEW YORK STATE RESIDENTIAL CODE 2020 A AMPERE INVERTER: 13 Enphase Energy Inc.:I08MC-72-M-US[240VI NEW YORK STATE FIRE CODE 2020 f� AC ALTERNATING CURRENT RAIL: 232-02536-USA-SNAPNRACK,UR-40 RAIL,1721N,MILL DC DIRECT CURRENT ATTACHMENT: 242-02167,SNAPNRACK:SPEEDSEAL FOOT �P` �o�'W.a • (�`O 105278 (� ESS ENERGY STORAGE SYSTEM • »'`° s•"`� A ESSl EXT EXTERIOR PE STAMP EXPIRATION DATE:041302027 INT INTERIOR ��e MPH MILES PER HOUR GENERAL NOTES s T� =1-W MSP MAIN SERVICE PANEL . SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIAL STRUCTURE. .� • NTS NOT TO SCALE • OBTAIN ALL NECESSARY PERMITS AND APPROVALS FROM LOCAL AUTHORITIES AND UTILITY COMPANIES BEFORE COMMENCING OC ON CENTER INSTALLATION. PSF POUNDS PER SQUARE FOOT venture sofa r • THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND UTILITY IS OBTAINED. PV PHOTOVOLTAIC SQ FT SQUARE FOOT • THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL OR BUILDING ROOF VENTS. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. Venture Solar V VOLT W WATT • PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED AS PER SECTION 110.26 NEC. 100 Charlotte Ave,Hicksville,NY 11801 . ALL COMPONENTS AND INSTALLATIONS SHALL MEET THE REQUIREMENTS SET FORTH BY RELEVANT INDUSTRY STANDARDS,INCLUDING IEEE r or AC I AC DISCONNECT AND UL.CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY. 42 West St,Brooklyn,NY 11222 UI BACKUP INTERFACE . MOUNTING STRUCTURES SHALL BE DESIGNED AND INSTALLED TO WITHSTAND WIND,AND SNOW LOADS AS REQUIRED BY LOCAL BUILDING www.venturesolar.com B m BAT BATTERY CODES. contact@venturesolar.com AERIAL VIEW(SCALE: NTS) BLP BACKUP LOAD PANEL • ALL SYSTEM COMPONENTS,INCLUDING PANELS,INVERTERS,DISCONNECTS,AND CONDUITS,SHALL BE CLEARLY LABELED AND MARKED (888)522-9161 FOR IDENTIFICATION AND SAFETY. CB COMBINER BOX • ALL WIRING,CONDUIT,AND CONNECTORS SHALL BE SIZED AND INSTALLED PER NEC REQUIREMENTS TO ENSURE PROPER CURRENT CONTRACTOR SIGNATURE DC DC DISCONNECT CARRYING CAPACITY AND PROTECTION. GW GATEWAY • CODE VIOLATIONS PRESENT IN INTERCONNECTION PANEL WILL BE CORRECTED UPON INSTALLATION. INV INVERTER • RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY POWER. PM PRODUCTION METER PROPERLY SIZED DISCONNECT SWITCHES AND OVERCURRENT PROTECTION DEVICES SHALL BE INSTALLED AT APPROPRIATE LOCATIONS REVISION M SP MAIN SERVICE PANEL TO ENSURE SAFE MAINTENANCE AND OPERATION. REV DESCRIPTION DATE • ALL METALLIC EQUIPMENT SHALL BE GROUNDED RSD RAPID SHUTDOWN DEVICE sc I SYSTEM CONTROLLER SITE INFORMATION SHEET INDEX SD SERVICE DISCONNECT AHJ: NY-SOUTHOLD TOWN PV01 COVER SHEET SUB SUB PANEL ELECTRIC UTILITY: PSEG LONG ISLAND(NY) PV02 SITE PLAN CUSTOMER NAME: U STRANSFER SWITCH WIND SPEED: 127 MPH PV03 ROOF LAYOUT KAREN KARP M UTILITY METER GROUND SNOW LOAD: 25 PSF PV04 ATTACHMENT DETAIL y AMBIENT TEMPERATURE: 30°C PV05 STRING LAYOUT ADDRESS: EXTERIOR EQUIPMENT EXTREME MINIMUM TEMPERATURE: -19°C PV06 LINE DIAGRAM 1400 LIGHTHOUSE RD, L___� INTERIOR EQUIPMENT NO. FLOORS: 1 PV07 ELECTRICAL CALCULATIONS AND NOTES - — SOUTHOLD, NY, 11971 DRIVEWAY pp���' t�TED PV08 LABELS AND PLACARD ELECTRICAL EQUIPMENT COORDINATES: ® FIRE SETBACK DA B.P.# o2 OCCUPANCY OR 41.0824425,-72.4383432 WORKING CLEARANCE F}����~�•`.. FEE o2m•OD BY: COMPLY WITH ALL CODES OF USE IS UNLAWFUL CONDUIT RUN NOTIFY BUILDING DEPARTMENT AT NEW YORK STATE St TOWN CODES APN: x - LOAD BEARING WALL 631-765-1802 8AMTO4PM FOR THE AS REQUIRED AND CONDITIONS OF WITHOUT CERTIFICATE #1000050000500003000 PROPERTY LINE FOLLOWING INSPECTIONS: SOUTHOLD TOWN ZBA ROOF FRAMING 1. FOUNDATION-TWO REQUIRED OF OCCUPANCY FOR POURED CONCRETE SOUTHOLD TOWN PLANNING BOARD SnapNrack- I(&® ROOF OBSTRUCTIONS 2. ROUGH-FRAMING&PLUMBING SOUTHOLD TOWN TRUSTEES MODULE 3. INSULATION N.Y.S.DEC Solar Mounting Solutions RAIL 4. FINAL-CONSTRUCTION MUST RETAIN STORM WATER RUNOFF SHEET NAME BE COMPLETE FOR C.O. SOUTHOLDHPC PURSUANT TO CHAPTER 236 ALL CONSTRUCTION SHALL MEET THE SCHD OF THE TOWN CODE. COVER SHEET REQUIREMENTS OF THE CODES OF NEW SHEET NUMBER YORK STATE. NOT RESPONSIBLE FOR RAIL SPLICE DESIGN OR CONSTRUCTON ERRORS Pvo1 ATTACHMENT DESIGN DATE:17-Sep-25 TEMPLATE V2025.04.02 ANSI FULL BLEED B(17.00 X 11.00 INCHES) CLOSE UP VIEW-SCALE: 3/32" = V-0" SITE PLAN -SCALE: 1/32" = V-0" ARRAY DETAILS F NEW y ARRAY MODULES ARRY HEIGHT RTILT OOF AZIMUTH PV AREA COVERAGE *Gj�Q \CK Bl/S,pE•�O� ` 1 7 1-STORY 36' 225° 147.13 SO.FT. 2 6 1-STORY 36° 135- 126.12 SQ.FT. W 2 105278 ESS10Na�. PE STAMP EXPIRATION DATE:04/30/2027 170'-S' —" ---� I NT7 __�_-_--- - "--- venture solar r"- I i129'7 i Venture Solar I I 100 Charlotte Ave,Hicksville,NY 11801 or I o I 42 West St,Brooklyn,NY 11222 18"FIRE SETBACK i (E)DETACHED STRUCTURE , wMnM.venturesolar.com ARRAY#1 - contact@venturesolar.com I I (888)522-9161 � I CONTRACTOR SIGNATURE O LADDER ACCESS POINT ; I 36"FIRE ACCESS PATHWAY I I N I I REVISION w I (E)RESIDENCE I REV DESCRIPTION DATE z Lu I I w LL I 'u;�'• I ARRAY#2 ❑ p I ❑ ar, I CUSTOMER NAME: KAREN KARP i (E)DRIVEWAY '-` A. ti cam;e LMSPJ I 'ma _ ?`�' I ADDRESS: 1400 LIGHTHOUSE RD, WITHIN 10' � " -`': SOUTHOLD, NY, 11971 I COORDINATES: i -- 41.0824425,-72.4383432 (N)JUNCTION BOX �_�-- 171'-7" APN: 1400 LIGHTHOUSE RD #1000050000500003000 36"FIRE ACCESS PATHWAY SnapNrack- Solar LADDER ACCESS POINT Mounting Solutions SHEET NAME SITE PLAN SHEET NUMBER PV02 DESIGN DATE:17-Sep-25 TEMPLATE V2025.04.02 ANSI FULL BLEED B(17.00 X 11.00 INCHES) ROOF LAYOUT -SCALE: 1/8"= V-O" RACKING EQUIPMENT SCHEDULE QTY F NEW yQ 232-02536-USA-SNAPNRACK,UR-40 RAIL,1721N,MILL 8 ` 242-01214--USA,SNAPNRACK,UR-40 SPLICE,BLACK 4 48"ATTACHMENT SPAN 10.. 242-02167,SNAPNRACK,UR SPEEDSEAL FOOT,BLACK 32 242-02168,SNAPNRACK,SEALING WASHER LAG,4-1/21N,SS 32 232-01173,SNAPNRACK,SMART CLIP 11 26 242-02071—USA,SNAPNRACK,ULTRA RAIL MID CLAMP,BLACK 20 �`O 105278 11* 242-10034,SNAPNRACK,OMNILUG 16 A/�f SSlp�p�' 232-02452,SNAPNRACK,UR-40 END CAP 12 PE STAMP EXPIRATION DATE:0 4/3012 0 2 7 242-02073,SNAPNRACK,ULTRA RAIL END CLAMP,BLACK 12 IT o� sK>na venture solar Venture Solar 100 Charlotte Ave,Hicksville,NY 11801 or 42 West St,Brooklyn,NY 11222 O www.venturesolar.com contact@venturesoler.com ❑ (888)522-9161 CONTRACTOR SIGNATURE REVISION IIIF-1 REV DESCRIPTION DATE z Z U SOLAR ARRAY AND a- CUSTOMER NAME: LOADING U KAREN KARP CALCULATION ° N MAIN HOUSE ADDRESS: #OF MODULE 13 1400 LIGHTHOUSE RD, PV AREA 21.02 SO FT SOUTHOLD, NY, 11971 TOTAL ARRAY 273.25 SQ FT AREA TOTAL ROOF 1807.23 SO F-1 COORDINATES: FT AREA 41.0824425,-72.4383432 PV AREA 15.12% o COVERAGE MODULE 47.40 LBS APN: WEIGHT TOTAL ARRAY #1000050000500003000 WEIGHT 616.20 LBS #OF 32 ATTACHMENT SnapNrack- DISTRIBUTEDPOINT LOAD 1.48 LBS 2.26 PSF LOAD Solar Mounting Solutions ARRAY DETAILS SHEET NAME ARRAY MODULES ARRAY ROOF AZIMUTH ROOF TYPE ROOF FRAMING RAFTER RAFTER RAIL ATTACHMENT ATTACHMENT ATTACHMENT ROOF LAYOUT HEIGHT TILT SIZE SPACING SPACING CONFIGURATION 232-02536-USA- 1 7 1-STORY 36' 225' COMP SHINGLE TRADITIONAL/STICK FRAMING 2"x 8" 24" SNAPNRACK,UR-40 RAIL, 242-02167,SNAPNRACK:SPEEDSEAL FOOT 48" STAGGERED SHEET NUMBER 1721N,MILL 232-02536-USA- PV03 2 6 1-STORY 36' 135' COMP SHINGLE TRADITIONAL/STICK FRAMING 2"x 8" 24" SNAPNRACK,UR-40 RAIL, 242-02167,SNAPNRACK:SPEEDSEAL FOOT 48" STAGGERED 1721N,MILL DESIGN DATE:17-Sep-25 TEMPLATE V2025.04.02 ANSI FULL BLEED B(17.00 X 11.00 INCHES) pf NEwyO NOTE: 5/16" LAG SCREWS TO BE EMBEDDED A MINIMUM OF 2-1/2" INTO FRAMING UNTIL NOTED OTHERWISE *`'Q� \`'Bus sF�� BIN: REVISION: SNAPNRACK UR SPEEDSEAL FOOT FOR COMPOSTION ROOF MOUNTING MODULE HEIGHT OFF ROOF, RANGE: i 3Io/zazo NEW DETAIL N1JA COMP SHINGLE ROOFING,TYP. 8 z /10202o DIE CAST BDP y — F41- V= UR-40: 3 8" 4 s" 3 7/22/20 0 NAME UPDATE MIA UR 60. 4" - 5 SNAPNRACK, UR SPEEDSEAL FOOT 4 10/2/2020 MIAMI-DADE MIA �Q 105278 REFER TO SNAPNRACK ENGINEERING CHARTS ROOF DECKING,TYP. a 8/21202I DC000595 MJA A�'OF�SS�pNP\' FOR APPLICABLE RAIL SPANS. _ C 3/29/2023 DC001948 MKW PE STAMP EXPIRATION DATE:04/30/2027 SNAPNRACK *ALTERNATE FASTENERS AND STRUCTURAL %6"O S.S. SUBSTRATES ARE PERMITTED. SNAPNRACK'S LAG SCREW,TYP. STANDARD ENGINEERING REQUIRES STRUCUTRAL MEMBER, MINIMUM FASTENER ALLOWABLE CAPACITIES WOOD RAFTER,TYP. OF 532 LBS WITHDRAWAL AND 270 LBS SHEAR. CAPACITIES LOWER THAN THIS WILL REQUIRE SITE-SPECIFIC ENGINEERING venture solar REFER TO SNAPNRACK INSTALLATION MANUAL FOR Y16"O HARDWARE TORQUE venture solar SPECIFICATIONS 100 Charlotte Ave,Hicksville,NY 11801 or SNAPNRACK SPEEDSEAL FOOT CAN MOUNT IN 42 West St,Brooklyn,NY 11222 ANY ORIENTATION ON THE ROOF www.venturesolar.com contact@venturesolar.com (888)522-9161 *MINIMUM EMBEDMENT, VARIES TO MEET MINIMUM CONTRACTOR SIGNATURE SNAPNRACK ULTRA CAPACITY REQUIREMENTS RAIL MOUNT,TAPPED /6"WASHER, S.S. REVISION (MAY INCLUDE NEOPRENE REV DESCRIPTION DATE PENETRATION DETAIL TYPE GASKET) COIL SPRING FOR s" 0 BOLT, S.S. SNAPNRACK, ULTRA RAIL MOUNT,THRU OPTIONAL CUSTOMER NAME: ,7=%r" FLAT WASHER,S.S. KAREN KARP 0 OPTIONAL O ADDRESS: SNAPNRACK,SPEEDSEAL Y16"O-18 X 2" BOLT, 1400 LIGHTHOUSE RD, FOOT, BASE, SEALING SERRATED FLANGE, S.S. SOUTHOLD, NY, 11971 EXPLODED CAVITY IN UR SPEEDSEAL FOOT COORDINATES: �11/2"j IS FILLED WITH SEALANT TO 41.0824425,-72.4383432 r111 ENCAPSULATE AND PROTECT I THE ROOF PENETRATION APN: FROM MOISTURE #1000050000500003000 2 4 15/,8 ROOF DECKING L R-60 RAIL SnapNrack- UR-40 RAIL I U STRUCTURAL MEMBER(RAFTER) FOR USE WITH SNAPNRACK ULTRA SERIES RAILS Solar Mounting Solutions Sunrun South LLC DESIGNER: M.AFFENTRANGER SCALE: DNS DRAWING NUMBER: DESCRIPTION: REV: SHEET NAME SnapNmck- <55M�ETSTREET,9T„F_.-- FRANOIs- A-I-USA ULTRA RAIL, ATTACHMENT DETAIL, UR P„�E;a,5;56Gaf0 �FAX(415SRb8302 DRAFTER: M.WATKINS SNR-DC-00438 ATTACHMENT DETAIL TIFF INFCR.UTION IN THISCRAN ING IS CONFIDENTIAL ANDRROPRIETARY.ANN DATE: 3/29/2023 SPEEDSEAL FOOT TO RAFTER REFRODXTION.DISCLOS.RE ORJSE THEREOF ISK.OHI6RFD'4TMCUTTHF APPROVED BY: M.AFFENTRANGER WRITTEN CONSENT CF SJNRUN SOUTH LLC. SHEET NUMBER PV04 DESIGN DATE:17-Sep-25 TEMPLATE V2025.04.C2 ANSI FULL BLEED B(17.00 X 11.00 INCHES) STRING LAYOUT-SCALE: 118" = V-0" venture solar Venture Solar 100 Charlotte Ave,Hicksville,NY 11801 1 1 1 1 1 1 1 or 42 West St,Brooklyn,NY 11222 www.venturesolar.com contact@venturesolar.com (888)522-9161 Q CONTRACTOR SIGNATURE REVISION REV DESCRIPTION DATE N ❑ CUSTOMER NAME: KAREN KARP N ADDRESS: 1400 LIGHTHOUSE RD, N SOUTHOLD, NY, 11971 COORDINATES: N 41.0824425,-72.4383432 F-1 N APN: #1000050000500003000 N SnapNrack Solar Mounting Solutions BRANCH 1: SHEET NAME 7 MODULE 7 MICROINVERTER STRING LAYOUT BRANCH 2: SHEET NUMBER 6 MODULE PV05 6 MICROINVERTER DESIGN DATE:17-Sep-25 TEMPLATE V2025.04.02 ANSI FULL BLEED B(17.00 X 11.00 INCHES) ELECTRICAL EQUIPMENT SCHEDULE QTY RATING INVERTER SPECIFICATION MODULE SPECIFICATION WIRE AND CONDUIT SCHEDULE JA SOLAR TECHNOLOGY: Enphase Energy Inc.: WIRE 13 440 W JA Solar Technology: CONDUIT CONDUCTOR NEUTRAL GROUND JAM54D41-440/MB INVERTER: IQSMC-72-M-US MODULE: JAM54D41-440/MB TAG ENPHASE ENERGY INC.:108MC-72-M-US 13 320 W [240V] 1 FREE AIR (2)12 AWG IQ CABLE,THWN2 NONE (1)6 AWG BARE COPPER [240V] NO.OF INVERTER: 13 NO.OF MODULE: 13 2 1"EMT (4)10 AWG THWN-2 NONE (1)10 AWG THWN-2 EATON:DG222NRB 1 60 A MAX OUTPUT POWER: 320.00 W MAX POWER: 440.00 W 3 1"EMT (2)6 AWG THWN-2 (1)6 AWG THWN-2 (1)8 AWG THWN-2 ENPHASE:X-10-AM1-240-5 1 125 A MAX INPUT VOLTAGE: 60.00 V OPEN CIRCUIT VOLTAGE: 39.38 V 4 2"EMT (2)3/0 AWG THWN-2 (1)3I0 AWG THWN-2 (1)6 AWG THWN-2 MAX INPUT CURRENT: 14.00 A SHORT CIRCUIT CURRENT: 13.85 A NOMINAL OUTPUT VOLTAGE: 240.00 V MAX POWER-POINT VOLTAGE: 33.37 V MAX OUTPUT CURRENT: 1.33 A MAX POWER-POINT CURRENT: 13.18 A TOTAL OUTPUT CURRENT: 17.29 A MAX FUSE RATING: 30 A TOTAL BACKFEED: 21.61 A MINIMUM OCPD SIZE: 25 A venture solar Venture Solar 100 Charlotte Ave,Hicksville,NY 11801 or 42 West St,Brooklyn,NY 11222 www.venturesolar.com contact@venturesolar.com (888)522-9161 PSEG LONG ISLAND(NY) METER# 98367412 CONTRACTOR SIGNATURE UTILITY ACCOUNT#. 9636128803 (N)EATCN:DG222NRB VISIBLE,LOCKABLE,BLADE, FUSIBLE AC DISCONNECT 60A, 240V,NEMA3R (N)ENPHASE:X-I0-AN11-240-5 (F)UTILITY METER 1PH, (N):JNCTION BOX 125A,24OV,NEMA 3R 1201240V,3W OR EQUIVALENT (E)200A TRANSFER SWITCH GROUNDING TO BE BONDED OVERHEAD SERVICE 120/240V.NEMA3R WITH NEUTRAL DEDICATED FOR PV LOADS ONLY REVISION TO GRID REV DESCRIPTION DATE BRANCH 2: (E)200A MAIN SERVICE PANEL (6)JA SOLAR TECHNOLOGY:JAN1541341-440/1VIe (E)200A-2P 200A BUS BAR 60 FUSES MODULE ENO FED ENVOY ,6)ENPHASE ENERGY INC.:IQ81MC-72-M-US[240V] MICROINVERTER (N)1aA-2P 2.640 KW DC GRID 1.920 KW AC E 4 (E)200A-2P 3 3 CUSTOMER NAME: 10FT LO 10FT 10FT (E)LOADS KAREN KARP PEN EZ SOLAR-JB-1 XL BRANCH 1: JUNCTION BOX (7)JA SOLAR TECHNOLOGY:JAM54D41-440/MB (E)LOADS 10WV.125A,NEMA 3R 1 MODULE E (7)ENPHASE ENERGY INC.:ICSIMC-72-M-US[24014 ADDRESS: (E)LOADS 25FT MICROINVERTER (N)2G4`2P 3.080K%VDC 1400 LIGHTHOUSE RD, (E)LOADS 2.240KWAC SOUTHOLD, NY, 11971 (N)2GA-2P (E)GROUNDING (E}LOADS ELECTRODE E)LOADS COORDINATES: (E)LOADS 2 - 1 41.0824425,-72.4383432 40FT SOFT TOTAL DC AND AC SYSTEM SIZE 5.720 KW DC APN: 4.160 KW AC #1000050000500003000 SnapNrack- Solar Mounting Solutions SHEET NAME LINE DIAGRAM SHEET NUMBER PV06 DESIGN DATE:17-Sep-25 TEMPLATE V2025.04.02 ANSI FULL BLEED B(17.00 X 11.00 INCHES) WIRE AND CONDUIT SCHEDULE WIRE CONDUCTOR PER AMBIENT TEMPERATURE RATING OF TEMPERATURE DEBATED WIRE TAG CONDUIT CONDUCTOR NEUTRAL GROUND TEMPERATURE WIRE WIRE AM DERATE FACTOR RACEWAY DEBATE AMPACITY OCPD CONDUIT FILL FACTOR 1 FREE AIR (2)12 AWG IQ CABLE,THWN2 NONE (1)6 AWG BARE COPPER 30'C 90°C-COPPER 30 A 1 1 30.00 A 20 A FREE AIR 2 1"EMT (4)10 AWG THWN-2 NONE (1)10 AWG THWN-2 30"C 90°C-COPPER 40 A 1 0.8 32.00 A 20 A 12.21% 3 1"EMT (2)6 AWG 7HWN-2 (1)6 AWG THWN-2 (1)8 AWG THWN-2 30°C 75°C-COPPER 65 A 1 1 65,00 A 60 A 21,84% 4 2"EMT (2)3/0 AWG THWN-2 (1)3/0 AWG THWN-2 (1)6 AWG THWN-2 30°C 75°C-COPPER 200 A 1 1 200.00 A 200 A 25.46% OUTPUT TOTAL BRANCH CALCULATIONS MAIN SERVICE PANEL ALLOWABLE BACKFEED EQUIPMENT Qn CURRENT OUTPUT BACKFEED Enphase Energy Inc.: 2 CURRENT IQBMC-72-M-US(240V] 1 MAIN BREAKER RATING 200 A Enphase Energy Inc.:I08MC-72-M-US PANEL RATING 200 A 13 1.33 A 17.29 A 21.61 A NO.OF MICROINVERTER 7 6 [240V] BUS RATING 200 A TOTAL: 17.29 A 21.61 A NOMINAL STRING VOLTAGE 240 V 240 V MAIN PANEL ALLOWABLE BACKFEED=MAIN BREAKER RATING venture sofa r ARRAY CURRENT 9.31 A 7.98 A 200A?21.61A BACKFEED DC SYSTEM SIZE 5720 W Venture Solar AC SYSTEM SIZE 4160 W DC/AC RATIO 1.38 100 Charlotte Ave,Hicksville,NY 11801 or 42 West St,Brooklyn,NY 11222 www.venturesolar.com contact@venturesolar.com (888)522-9161 CONTRACTOR SIGNATURE REVISION REV DESCRIPTION DATE CUSTOMER NAME: KAREN KARP ADDRESS: 1400 LIGHTHOUSE RD, SOUTHOLD, NY, 11971 COORDINATES: 41.0824425,-72.4383432 ELECTRICAL NOTES OF METAL COMPONENTS,GROUNDING ELECTRODES,AND PROPER BONDING TO MINIMIZE ELECTRICAL HAZARDS. • PHOTOVOLTAIC MODULES AND INVERTERS USED IN THE SYSTEM SHALL BE LISTED AND LABELED FOR THEIR • DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS APN: INTENDED USE AS PER NEC 690.4 AND 690.5,ENSURING COMPLIANCE WITH INDUSTRY STANDARDS AND SAFETY REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED"LINE SIDE"(TYPICALLY UPPER TERMINALS) #1000050000500003000 REGULATIONS. • EMERGENCY DISCONNECTS SHALL BE INSTALLED IN READILY ACCESSIBLE LOCATIONS,ENSURING SAFE AND • ALL EQUIPMENT SHALL MEET THE MINIMUM CLEARANCES AS REQUIRED BY NEC 110.26 EFFICIENT SHUTDOWN IN CASE OF EMERGENCIES. �� ����� • JUNCTION BOXES AND PULL BOXES ARE PERMITTED TO INSTALL UNDER PV MODULES PER NEC 690.34 • RAPID SHUTDOWN REQUIREMENTS SHALL BE MET,ENSURING THAT THE PV SYSTEM CAN BE DE-ENERGIZED TO A • ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE SPECIFIED VOLTAGE WITHIN A CERTAIN TIME FRAME,FACILITATING FIREFIGHTER SAFETY DURING EMERGENCIES. • WIRING METHODS SHALL FOLLOW NEC GUIDELINES,INCLUDING PROPER RACEWAY SELECTION,CONDUIT SIZING,AND • PROPERLY SIZED OVERCURRENT PROTECTION DEVICES SHALL BE INSTALLED TO PROTECT CONDUCTORS AND Solar Mounting Solutions SEPARATION FROM OTHER CIRCUITS TO PREVENT DAMAGE AND MAINTAIN CIRCUIT INTEGRITY.CONDUIT AND WIRE COMPONENTS.COORDINATION WITH MODULE SHORT-CIRCUIT CURRENTS AND OVERCURRENT DEVICE RATINGS SHEET NAME SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. SHALL BE ENSURED. ELECTRICAL CALCULATION • VOLTAGE DROP IS LIMITED TO 2% • SOURCE AND OUTPUT CIRCUITS SHALL BE APPROPRIATELY SIZED AND PROTECTED,WITH PROPER INSULATION AND AND NOTES • DC WIRING LIMITED TO MODULE FOOTPRINT.MICORINVERTER WIRING SYSTEM SHALL BE LOCATED AND SECURED LABELING TO PREVENT ANY RISK OF ELECTRICAL HAZARDS. SHEET NUMBER UNDER THE ARRAY WITH SUITABLE WIRING CLIPS • LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH NEC 705.12(B) • GROUNDING AND BONDING OF PV SYSTEMS SHALL COMPLY WITH NEC REQUIREMENTS.THIS INCLUDES GROUNDING • SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12(A)WITH SERVICE ENTRANCE CONDUCTORS IN PV07 ACCORDANCE WITH NEC 230.42 DESIGN DATE:17-Sep-25 TEMPLATE V2025.04.02 ANSI FULL BLEED B(17.00 X 11.00 INCHES) LABELING NOTES: 1. ENSURE LABELS ALIGN WITH COMMON CONFIGURATIONS,ALLOWING ELECTRICIANS TO ADJUST PER NEC AND LOCAL CODES. 2. ADHERE TO LABELING REQUIREMENTS BASED ON 2017 NEC,OSHA STANDARD 1910.145,AND ANSI Z535, FOLLOWING AHJ SPECIFICATIONS. ' 3. MATERIALS MUST MEET AHJ REQUIREMENTS FOR DURABILITY IN THE GIVEN ENVIRONMENT(NEC 110.21(B)(3)). CAUTION 4. LABELS SHOULD HAVE A MINIMUM 3/8"LETTER HEIGHT,WHITE ON RED BACKGROUND,REFLECTIVE,AND PERMANENTLY AFFIXED(NEC 690.31(G)). POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE 5. EFFECTIVELY COMMUNICATE HAZARDS THROUGH WORDS,COLORS,AND SYMBOLS ON LABELS,COMPLYING WITH NEC ARTICLE 110.21(B). ! FOLLOWING SOURCES WITH DISCONNECT AS SHOWN 6. PERMANENTLY AFFIX LABELS WITHOUT COVERING EXISTING MANUFACTURER LABELS. LABEL LOCATION: LABEL LOCATION: INVERTER(S), AC/DC WARNING-., AC COMBINER PANEL(IF APPLICABLE). I WARNING APPLICABLE), ADJACENT ).PV BREAKER(IF 7EERICAL SHOCK HAZARD PER CODE(S):NEC 2017:690.13(B) POWER SOURCE OUTPUT CONNECTION PER CODE(S):NEC 2017: 705.12(B)(2)(3)(b) LS ON LINE AND LOAD SIDES DO NOT RELOCATE THIS E ENERGIZED IN THE OPEN OVERCURRENT DEVICE POSITION A N I N G LABEL LOCATION: I LABEL LOCATION: Venture so la r PV LOAD CENTER(IF APPLICABLE)AND UTILITY SERVICE METER AND MAIN ANY PANEL THAT UTILIZES"THE SUM SERVICE PANEL. x 1 Venture Solar OF BREAKERS RULE",MAIN SERVICE THREE POWER SUPPLY PER CODE(S):NEC 2017:705.12(B)(3) x0 7EQUIPMENT FED BY PANEL CES.TOTAL PER CODE(S):NEC 2017 SOURCES: UTILITY GRID, m PV MODULE AND 100 Charlotte Ave,Hicksville,NY 11801 705.12(B)(2)(3)(c) GENERATOR AND PV SOLAR A MICROINVERTER or RATING OF ALL OVERCURRENT ELECTRIC SYSTEM o 42 West St,Brooklyn,NY 11222 DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE www.venturesolar.com SHALL NOT EXCEED AMPACITY contact@venturesolar.com OFBUSBAR (888)522-9161 YOU ARE HERE LABOR NO MORE THAT 1 M(3 FT)EL LOCATION: UTILITY METER(EXT) CONTRACTOR SIGNATURE SOLAR PV SYSTEM ON FROM THE SERVICE TRANSFER SWITCH(EXT) MAIN SERVICE PANEL(INT) EQUIPPED WITH RAPID DISCONNECTING MEANS TO WHICH RAPID SHUTDOWN THE PV SYSTEMS ARE CONNECTED. AC DISCONNECT(EXT) SHUTDOWN PER CODE(S):NEC 2017: COMBINER BOX(EXT) REVISION 690.56(C)(1)(A) REV DESCRIPTION DATE TURN RAPID FRONT OF RESIDENCE SHUTDOWN SWICH TO SOLAR ELECTRIC THE"OFF"POSITION TO PANEL SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN CUSTOMER NAME: ARRAY PLAQUE SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. KAREN KARP ADDRESS: RAPID LABEL LOCATION: 1400 LIGHTHOUSE RD, 1 , SHUTDOWN UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT(IF SOUTHOLD, NY, 11971 APPLICABLE).INSTALLED WITHIN 3' SWITCH • SOLAR OF RAPID SHUT DOWN SWITCH PER CODE(S):NEC 2017:690.56(C)(3) COORDINATES: PV SYSTEM 41.0824425,-72.4383432 LABEL LOCATION: APN: PV SYSTEM DISCONNECT UTILITY SERVICE ENTRANCE/METER, #1000050000500003000 INVERTER/DC DISCONNECT(IF APPLICABLE).INSTALLED WITHIN 3'OF RAPID SHUT DOWN SWITCH MAXIMUM AC _ •P 17.29 AMPS PER CODE(S):NEC 2017:690.54 SnapNrack- Solar• •- • VAC Mounting Solutions LABEL LOCATION: SHEET NAME GENERATION DISCONNECT • AC DISCONNECT LABELS AND PLACARD SWITCH SHEET NUMBER PV08 DESIGN DATE:17-Sep-25 TEMPLATE V2025.04.02 ANSI FULL BLEED B(17.00 X 11.00 INCHES)