Loading...
HomeMy WebLinkAbout51957-Z �o�aoF souTyO`o Town of Southold * * P.O. Box 1179 �o0 53095 Main Rd UN".N�' Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46746 Date: 12/23/2025 THIS CERTIFIES that the building GENERATOR Location of Property: 2880 Mhmehaha Blvd Southold, NY 11971 Sec/Block/Lot: 8 7.-3-4 3 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 04/23/2025 Pursuant to which Building Permit No. 51957 and' dated: 05/29/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Accessory standby generator at existing single-family dwelling as applied for. The certificate is issued to: Richard Perl, Stephanie Perl Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 51957 6/27/2025 PLUMBERS CERTIFICATION: Autho Jed SignatulU �,�oFso�,yo TOWN OF SOUTHOLD BUILDING DEPARTMENT • TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 51957 Date: 05/29/2025 Permission is hereby granted to: Richard Perl 214 Barnstable Dr Wyckoff, NJ 07481 To: Install accessory standby generator at existing single family dwelling as applied for,with Trustees #10728 and flood permit. *Generator installation must be compliant with FEMA flood zone AE6 Premises Located at: 2880 Minnehaha Blvd,Southold, NY 11971 SCTM#87.-3-43 Pursuant to application dated 04/23/2025 and approved by the Building Inspector. To expire on 05/29/2027. Contractors: Required Inspections: Fees: GENERATOR $125.00 CO Accessory $100.00 ELECTRIC-Residential $100.00 Flood Permit $150.00 Total 475.00 Building Inspector pF SO!/lyol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G • OQ Southold,NY 11971-0959 C4UNT`I,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Richard Perl Address: 2880 Minnehaha Blvd City: Southold St: NY Zip: 11971 Building Permit#: 51957 Section: 87 Block: 3 Lot: 43 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: Electrician: Alan Hubbard Electrical License No: 4285ME SITE DETAILS Office Use Only Indoor r Basement r Service I— Solar (— Outdoor W 1st Floor r Pool r Spa r Renovation 1- 2nd Floor I— Hot Tub F Generator I✓ Survey r Attic Garage rl Battery Storage (— INVENTORY Service 1 ph I— Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph r Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 200A UC Lights Dryer Recpt Emergency Strobe Heat Detectors Disconnect Switches 4'LED Exit Fixtures Other Equipment: 20kW Kohler Generator w/200A Transfer Switch Notes: Generator Inspector Signature: X Date: June 27, 2025 Sean Devlin Electrical Inspector sean.deviin(-town.southold.ny.us 2880MinnehahaGenerator OF SOUlyolo 67 # # TOWN OF SOUTHO LD BUILDING ING DEPT. Couto, 631-765-1802 INSPECTION [ ] FOUNDATION 1 ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION' [ ] ELECTRICAL (ROUGH) )4ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: _N Of DATE INSPECTOR 51-I 1 hO��OF 50GTyO� "�/ # # TOWN OF SOUTHOLD BUILDING DEPT. �os�m� 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ WFINAL �e*-- FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]. RENTAL REMARKS: ea o& , 2 GVa-ill ce2--h-A c G "') e-' 6 Cor-Ag, . . DATE `�- 30��� INSPECTOR o,%wot.rCal TOWN OF SOUTHOLD—BUILDING DEPARTMENT m� y x Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax (631) 765-9502 https://www.southoldtowm.jzov �c Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. J/ Building Inspector: APR 2 2 2025 Applications and forms must be filled out in their entirety.Incomplete BElc €4 �g Oelrerften11 applications will not be accepted. Where the Applicant is not the owner,an Town of Southold Owner's Authorization form(Page 2)shall be completed. ' Date: c j OWNER(S)OF PROPERTY: Name: SCTM#1000- Project Address: __---- Phone#: tj l—_ Ls____3_I�o Email' er I e f7'1 S 4 Mailing Address: CONTACT PERSON: Name: Mailing Address:_Yd _ /`D 3C -ZZ�I - — ---U-d0�__� _� �-- - ._- --------- - � � Phone#: � (p1 ----- Email: t �ba- fir DESIGN PROFESSIONAL PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION:. Name: A /0- k, Mailing Address: ®Q 'fix__ :Z l 1,C.� U Lt-e�.. A-)X-- Phone# .Email �� 'DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: 90ther fteW q Will the lot be re-graded? ❑Yes [:]No Will excess fill be removed from premises? ❑Yes ❑No 1 S � PROPERTY INFORMATION Existing use of property: J-eSj d.eA,,,--f -,c_ Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ONO"IF YES, PROVIDE A COPY. Q Check Box After Reading:.The owner/contractor/design professional is responsible for all`drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein,described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in buildings)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 220.45 of the New York State Penal Law. P Application Submitted By(print name): ❑Authorized Agent ❑Owner Signature of Applicant: �] STATE OF NEW YORK) CONNIE D. BUNCH Notary Public,State of New York SS: No.01 BU6185050. COUNTY OF ) Qualified in Suffolk County / Commission Expires April 14,2 A �'4 n ��u J�J Ce-�� being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the � �ra 'U�d (Contractor,Agent,Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this r)b�day of "� , 20�d' 'V �J`�`1 G) Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) residing at- do I, d g hereby authorize /% <�� �l` G�� to apply on my behalf to the n of thold Building Department for approval as described herein. Z A1 Owner's S gnature Date 4� �, Print Owner's Name 2 o�SUFFoc t�oG TOWN OF SOUTHOLD—BUILDING DEPARTMENT �� s2 y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 oy�o• �ao�� Telephone (631) 765-1802 https://www.southoldtownny.gov Floodplain Development Permit Application PROPERTY INFORMATION: Flood Zone: FIRM Panel: SCTM#1000- 7 Address: City: so-- A/� Zip: CONTACT PERSON: Name: D Phone#: ?ivl, 21S—— Mailing Address: ,PROJECT DESCRIPTIONS SECTION A:STRUCTURAL DEVELOPMENT'(CHECK ALL THAT APPLY) Type of Structure Type of Structural Activity Residential (1 to 4 families) ❑ New structure ❑ Residential (more than 4 families) El Demolition of existing structure ❑ Combined use ❑ Replacement of existing structure ❑ Non-residential ❑ Relocation of existing structure ❑ Elevated ❑ Addition to existing structure ❑ Flood proofed(attach certification) ❑ Alteration to existing structure ❑ Manufactured Home G3'Other: Q eVje_VC lY ❑ Located on individual lot ❑ Located in manufactured home park SECTION B: OTHER DEVELOPMENT(CHECK ALL THAT-APPLY) ❑ Clearing of trees,vegetation or debris ❑ Mining ❑ Grading ❑ Drilling ❑ Dredging ❑ Connection to public utilities or services ❑ Paving ❑ Placement,of fill material ❑ Drainage improvement(including culvert work) ❑ Roadway or bridge construction ❑ Fence or wall construction ❑ Watercourse alteration (attach description) ❑ Excavation (not related to a structured development) ❑ Other development not listed (specify): By signing below I agree to the terms and conditions of this permit and certify to the best of my knowledge the information contained in this application is true and accurate. I understand that no work may start until a permit is issued.The permit may be revoked if any false statements are made herein. If revoked,all work must cease until permit is re-issued. Development shall not be used or occupied until a Cert.of Compliance is issued.The permit will expire if no work is commenced,within one year of issuance.Other permits may be required to fulfill regulatory requirements.Applicant gives consent to local authority or representative to make reasonable inspections to verify compliance: Application Submitted By(print name): Signature of Applicant: AV lcleIL y Date: Z� Z� U.S. DEPARTMENT OF HOMELAND S fR I b:1660-0008 Federal Emergency Management �A' 'cy NOV 2 0 2_' lion e National Flood Insurance Program ELEVATION CERTIFICATE IMPORTANT: MUST FOLLOW THE INSTRUCTIONS ON INSTRUCTIOWPAGE9'i-ill." Copy all pages of this Elevation Certificate and all attachments for(J.),commurilt -building owner. y official,(2).insurance.agent/company;and,(3). SECTION INFORMATIONU NCE=MPANY-USE. 7 7­1,1' A PROPERTY Al. Building Owner's Name: Richard&Stephanie Per] Policy Num A2. Building Street Address(including Apt.,Unit,Suite,and/or Bldg.No.)or P.O.Route and Box No ornpany 2880 Minnehaha-Boulevard City: Southold State: , NY ZIP Code: 11971 A3. Property Description(e.g.,Lot and Block Numbers or Legal Description)and/or Tax Parcel Number. .SCTM No. 1000-87-3-43 A4. Building Use(e.g., Residential, Non-Residential,Addition,Accessory,etc.): Residential A5. Latitude/Longitude: Let.41*02'.14'! Long.72-25'38" Horiz.Datum:E] NAD 1927 E] NAD 1983 WGS 84 A6. Attach at least two and when possible four clear color photographs(one for each side)of the building(see Form pages 7 and 8). AT Building Diagram Number: — 8 A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s): 1,715 sq.t b) Is there at least one permanent flood opening on two different sides of each enclosed area? N Yes EJ No E] N/A c) Enter number of permanent flood openings in the crawlspace or enclosure(s)within 1.0 foot above adjacent grade: Non-engineered flood openings: Engineered flood openings: 7- d) Total net open area of non-engineered flood openings in A8.c:,—sq.in. e) Total rated area of engineered flood openings in A8.c(attach documentation—see Instructions): 1,4.00,sq.ft. 0 Sum of A8.d and A8.e rated area(if applicable—see Instructions): N/A sq.ft. A9. Fora building with an attached garage: a) Square footage of attached garage:; 90 sq.ft. b) Is there at least one permanent flood opening on two different sides of the attached garage? E]Yes X No 0 N/A c) Enter number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade: Non-engineered flood openings: Engineered flood openings: d) Total net open area of non-engineered flood openings in A9.c: .,-.,- -sq.in. e) Total rated area of engineered flood openings in A9.c(attach documentation—see Instructions):, sq.ft. f) Sum of Ag.d and A9.e rated area(if applicable—see Instructions): --sq,ft. 'SECTION 8—FLOOD INSURANCE RATE MAP(FIRM)INFORMATION Bl.a. NFIP Community Name:Town of Southold Bl.b.NFIP Community Identification Number.'86 0,813 B2.County Name:Suffolk B3.State:NY B4.Map/Panel No.: 166 of 1026 B5.Suffix:. B6. FIRM Index Date: 09/25/2009 B7. FIRM Panel Effective/Revised Date: 09/25/2009 B8. Flood Zone(s): AE,&Shaded X B9. Base Flood Elevation(s)(BFE)(Zone AO,use Base Flood Depth): 6 B10. Indicate the source of the BFE data or Base Flood Depth entered in Item 139: ❑ FIS Z FIRM []Community Determined ❑Other. Bl 1. Indicate elevation datum used for BFE in Item 139: 0 NGVD 1929 Z NAVD 1988 ❑Other/Source: B12. Is the building located in a Coastal Barrier Resources System(CBRS)area or Otherwise Protected Area(OPA)? ❑Yes No Designation Date:' E]CBRS r❑]OPA 1313. Is the,building located seaward of the Limit of Moderate Wave Action(UMWA)7 E]Yes M:No FEMA Form FF-206-FY-22-152(formerly 086-0-33)(8123) Form Page 2 of 8 .t ELEVATION CERTIFICATE IMPORTANT:MUST FOLLOW THE INSTRUCTIONS ON INSTRUCTION PAGES 1-11 Building Street Address(including Apt., Unit,Suite,and/or Bldg.No.)or P.O.Route and Box No. FOR INSURANCE COMPANY USE 2880 Minnehaha Boulevard ' Policy Number City: Southold State: NY, ZIP Code: 11971 Company NAIC Number: SECTION`C BUILDING ELEVATION INFORMATION(SURVEY REQUIRE=D) . ', C1. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* ® Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations—Zones Al—A30,AE,AH,AO,A(with BFE),VE,V1 V30,V(with BFE),AR,AR/A,AR/AE,AR/A1—A30,AR/AH,AR/AO, A99.Complete Items C2.a—h below according to the Building Diagram specified in Item A7. In Puerto Rico only,enter meters. Benchmark Utilized: Vertical Datum: Indicate elevation datum used for the elevations in items a)through h)below. ❑ NGVD 1929 ® NAVD 1988 ❑Other: . Datum used for building elevations must be the same as that used for the BFE.Conversion factor used? ❑ Yes ® No If Yes,describe the source of the conversion factor in the Section D Comments area. Check the measurement used: a) Top of bottom floor(including basement,crawlspace,or enclosure floor): 4.3 ® feet ❑ meters b) Top of the next higher floor(see Instructions): 80 M feet ..❑ meters c) Bottom of the lowest horizontal structural member(see Instructions): N/A ❑ feet meters d) Attached garage(top of slab): _7.0 ® feet ;(] meters e) Lowest elevation of Machinery and Equipment(M&E)servicing the building (describe type of M&E and location in Section D Comments area): 5.9 ® feet ❑ meters f) Lowest Adjacent Grade(LAG)next to building: ❑ Natural ® Finished 4.5 ® feet ❑ meters g) Highest Adjacent Grade(HAG)next to building: ❑ Natural ® Finished 6.9 ® feet ❑ meters h) Finished LAG at lowest elevation of attached deck or stairs, including structural support: 4.4 feet ❑ meters "SECTION D'=SURVEYOR,ENGINEER,OR ARCHITECT GERTIFIGATION This certification is to be signed and sealed by a land surveyor,engineer,or architect authorized - uthorized by state law to certify elevation information.I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? ❑Yes ®No ®Check here if attachments and describe in the Comments area. Certifier's Name:Anthony Portillo License Number 037405 Title: Architect D A Company Name:AMP Architecture c��y��� M. o RE . Address:.10200 Main Road, Unit.3A Pe O City: Mattituck State. NY ZIP Code: 11952 - __ Telephone: (631)603-9092 Ext.: Email:aportillo@amparchitect.com 9TF° yo �FNE`N Signature: ,cQ �6� Date:_1.1/18/2025 Place Seal Here Copy all pages of this Eleva n Certificate and all attachments for(1)community official,(2)insurance agent/company,and(3)building owner.. Comments(including source of conversion factor in C2;type of equipment and location per C2.e; and description of any attachments): The lowest equipment servicing the building is an A/C condenser located at the North side of the dwelling. Dual-function smart vent specifications attached. Generator located.on..raised:platform above DFEat elevation 8.3'. FEMA Form FF-206-FY-22-152(formerly 086-0-33)(8/23) Form Page 3 of 8 ELEVATION CERTIFICATE IMPORTANT: MUST FOLLOW THE INSTRUCTIONS ON INSTRUCTION PAGES 1-11 BUILDING PHOTOGRAPHS Continuation Page Building Street Address(including Apt., Unit,Suite,and/or Bldg.No.)or P.O. Route and Box No.: FOR INSURANCE COMPANY USE 2880 Minnehaha Boulevard Policy Number: City: Southold State: NY ZIP Code: 11971 Company NAIC Number: Insert the third and fourth photographs below. Identify all photographs with the date taken and"Front View,""Rear View," "Right Side View,"or"Left Side View."When flood openings are present, include at least one close-up photograph of representative flood openings or vents, as indicated in Sections A8 and A9. r 4 Pncty T iifec Photo Three Caption: Rear(East Side)10.142025 Clear Photo Three t , s �A y Photo hour Photo Four Caption: Left (North Side) 10.14.2025 Clear Photo Four FEMA Form FF-206-FY-22-152(formerly 086-0-33)(8123) Form Page 8 of 8 ELEVATION CERTIFICATE IMPORTANT: MUST FOLLOW THE INSTRUCTIONS ON INSTRUCTION PAGES 1-11 BUILDING PHOTOGRAPHS See instiuubui16 iui ;'mni no. Building Street Address(including Apt., Unit,Suite,and/or Bldg. No.)or P.O. Route and Box No.: FOR INSURANCE COMPANY USE 2880 Minnehaha Boulevard Policy Number: City: Southold State: NY ZIP Code: 11971 Company NAIC Number: Instructions: Insert below at least two and when possible four photographs showing each side of the building(for example, may only be able to take front and back pictures of town houses/rowhouses). Identify all photographs with the date taken and"Front View,"'Rear View," "Right Side View,"or"Left Side View."Photographs must show the foundation.When flood openings are present, include at least one close-up photograph of representative flood openings or vents,as indicated in Sections A8 and A9. lifti g M Photo One Photo One Caption: Front(West Side)10.14.2025 Clear Photo One MI WPM -m'J J i J{ v Photo I wo Photo Two Caption: Right(South Side) 10.14.2025 Clear Photo Two FEMA Form FF-206-FY-22-152(formerly 086-0-33)(8/23) Form Page 7 of 8 Glenn Goldsmith,President QF SOUTy Town Hall Annex A.Nicholas Krupski,Vice President ,`O Ol0 54375 Route 25 P.O.Box 1179 Eric Sepenoski It Southold,New York 11971 Liz Gillooly G Telephone(631) 765-1892 Elizabeth Peeples Fax(631) 765-6641 �yCOUNTY,�c� BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD Permit No.: 10886A Date of Receipt of Application: December 1, 2026 Applicant: Stephanie Perl SCTM#: 1000-87-3-43 Project Location: 2880 Minnehaha Boulevard, Southold Date of Resolution/Issuance: December 17, 2025 Date of Expiration: December 17, 2028 Reviewed by: Board of Trustees Project Description: Install a generator. Findings: The project meets all the requirements for issuance of an Administrative Permit set forth in Chapter 275 of the Southold Town Code. The issuance of an Administrative Permit allows for the operations as indicated on the survey-prepared by Scalice Land Surveying, received on December 1, 2025, and stamped approved on December 17, 2025. Special Conditions: None. Inspections: Final Inspection. If the proposed activities do not meet the requirements for issuance of an Administrative Permit set forth in Chapter 275 of the Southold Town Code, a Wetland Permit will be required. This is not a determination from any other agency. H Glenn Goldsmith, President Board of Trustees Glenn Goldsmith, President a�®f S0 Town Hall Annex A. Nicholas Krupski,Vice President ®�v ®�® 54375 Route 25 P.O. Box 1179 Eric Sepenoski b Jlza IV Southold, New York 11971 Liz Gillooly Telephone(631) 765-1892 Elizabeth Peeples • �® Fax(631) 765-6641 COUNTi,� BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD CERTIFICATE OF COMPLIANCE # 2336 C Date: December 22, 2025 THIS CERTIFIES that the installation of a generator, J At 2880 Minnehaha Boulevard, Southold Suffolk County Tax Map#1000-87-3-43 Conforms to the application for a Trustees Permit heretofore filed in this office Dated December 1, 2025 pursuant to which Trustees Administrative Permit#10886A Dated December 17, 2025,was issued and conforms to all of the requirements and conditions of the applicable provisions of law. The project for which this certificate is being issued is for the installation of a generator. The certificate is issued to STEPHANIE PERL owner of the aforesaid property. PS Authorized Signature r 11 ! �•� �f�c. y L l� J La 7 3„', DEC 2 2 2025 =E /a® .� a S1 I& Town Hall Annex Telephone(631)765-1802 54375 Main Road N m�ax(631)76 g5QQ22 P.O.Box 1i79 G. Q roger.richertE -town.sou 016.ny.us Southold,NY 11971-0959 �l C ``�� E G E a , (� OUM APR 2 2 2025 BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL 1NSPECTIO .tdlia"g Dare-as tment own ofsouthoW REQUESTED BY: /��6h- � Date: Company Name: *Aj66, i2_b Name: License No.: f� — /Y (s- Address: Phone No.: 631- &5-7— /. 7 / (j icc ( 016 JOBSITE IN (*Indicates required information) )! *Name: Leh PCP L- *Address: C2 gro /Y) o mi�5-h,4 ti 9 A iud F >e_ *Cross Street: ®P ec A Ly — X: *Phone No.: Permit No.: 5 S yC Tax Map District: 1000 Section: ? . Block: 3 Lot:g *BRIEF DESCRIPTION OF WORK(Please Print Clearly) 1uJ,tF,6(j &j/f-o Ie (Please Circle All That Apply) *Is job ready for inspection: YE / NO Rough In Final *Doyou need a Temp Certificate: YES kNO Temp Information (If needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION .82=Request for Inspection Form solo.yol � o Town Hall Annex Jf Telephone(631)765-1802 54375 Main Road ax(631)765- 5 roger.richertCa town.soutf9i l P.O.Box 1179 CAR •� Q o nY.U$ Southold,NY 11971-0959 'cQl . BUILDING DEPARTMENT A r R 2 2 2025 TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL 1NSPECTIO �wn� � a""e [Address: ESTED BY: P,��� � ! � Date: any Name: 69 '8066A�P2,D E1e0��C Z L 6 t�%cA,_ C. e No.: Ll !No.: . 63 1 - &1-7-. l 7 JOBSITE INFORMATION: (*Indicates required information) Name: PGP-,L *Address: r� l i; yLjo)c-h a A d ,- *Cross Street: O p ec t�- A 1, K *Phone No.: Permit No.: Tax-Map District: 1000 Section: ? Block: Lot: �� *BRIEF DESCRIPTION OF WORK (Please Print Clearly) (Please Circle All That Apply) *Is job ready for inspection: YE / NO Rough In Final *Do you need a Temp Certificate: YES NO Temp Information(if needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION .82=Request for Inspection Form PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fridge HW POOL Fans Mini Fr. W/D PanelPump Exhaust Oven Sump Heater Trnsfmr Smokes DW Generator Salt Gen. Carbon Micro GrbDis Water Bond Lights Heat Pucks ERV HOT TUB/SPA Inst Hot DeHum Transfer Disc Combo Cooktop Minisplit Blower AC AH Hood Blower Service Amps Have Used Sub Amps Have Used CommentsP-64 LANDWARD EDGE DF.TIDAL:WETLANDS AS DELINEATED BY SUFFOLK ENVIRONMENTAL CONSUL TING,INC. ON JANUARY 20, 2010 f>jR WETLANDS FLAG JP- TN (SOm� 1 16427, s, /aeP E• ¢y /tned'cpOp ?�y " a 111 I , O pdpi���� ta4. -� � •• � w ^- JCr�R'nro a Imc tt��GOOD f�•*Phq,�j p'9 'TN . :5�0� `rA sRP li S. 88 59 00' PR1ET . apECHE ' RAIN RUNOFF- EXISTING HSE•, GAR. B PATIO 2454 Sq./1.. PROP ADOIT NS 1070 sq./I. DRIVEWAY,.'WA'LK'& SHED 61 fi sq.l. 4140 wvl! 41.40x1 X0.17= 70:4:cull 7Q41422 =16 7 VF PROVIDE 4 DWs-8'0•4.5''deep.OR EQUAL SURVEYDF LEADERS AND GUTTERS WILL BE -PROPERTY CONSTINSTALRUCTION BY COMPLETION OF A T-LAUGHING CONSTRUCTION ,.•� ' ; } r �a�:l�w`N. .._... �'c:�•. ,• t > n .,. m.. - LOT COVERAGE-'22 454 sq./l. UPLANDS TOWN OF SOU'T14OLO I� 4I20/22454 = re 3°.1 . SUFFOLK COUNTY.,'N.Y 1000--67-03-43 PE RIED CD�TSOOLA Scale: 1=30' i ABSTRACTS,'INCORPORATED. J(J1y 18, 2003 Aug, 13, 2003(Cerllf/caflons). A�. 23, y, ,d7 I; l . L OOD ZONE S FROM �I I RM 36103CO166H Ocf. G,2oo9(fo.{/r ! .fYCC Q ggDO9/ E EVATIONS ARE REFERENCED TO JAyNU/(RY 25, PrrVV (if�TNDS FLAGS)' AI VO Be MIP.T,14�,2010 radlran!Il locallor) _ AIEA- 24,380.sq. ft to tie lines OF Nelvr y���y(.MET�CC'Q� ANY ALTERATION OR ADDITION TO THIS SURVEY IS A V/OLA770M �o i fif, ppFF$EC77ON 7709 OF'THE'NEW YORK STATE EDUCATION LAW, , c":' EXCEPT AS PE74'SECTlgV 7209-SEMVIS/ON 2 ALL CER7Ih7CA710A/S rSt c='?,_ HEREON ARE VALID fLIR 7MS AfAP-AND COPES THE, ONLY IF € . � i SAND MAP OR COPlCtiS BEAR 7HE(l>PRE n SEAL OF THE SURVEYOR• �'}r i WHOSE SIGNATURE iiPPEi7RS HEFEG311L � •�� :.., �! �pOITIONALLY TO-COAFL.Y•WIRI.$AiD LAW-TESW•ALTEnt6 BY• CONIC`"S R MUST BE USED'BY ANY AND ALL SURVEYORS UnUMVG A COPY 3J1 765 5020 6���j S /797 OF ANOTHER SURVEYORS MAP..BERMS SUCH•INSPECTED!AND P. O. BOX 909 BROUGHT-TO,DATE;.'ARE NOT IN COMPLIANCE W?H THE.LAW. I230 TRAVELER STREET !• SOUTHOLD, N.Y. . 11971 03-206 NOTE:FEN RDOD UNES PlMFS THE BE4R M.S SWAN HEREON ARE BASE SYMBOL LEGEND PER FEN MW ON llBFI7 13M PAGE 0848 [7 mamAwN7 RAB a IAAff-'aF �4c+`iSr dNE 0LP./.b.FIFO T`q 4S7 'e-INLLF 1REE 0 LP.pa 3ET 0•Ir_�'av t]sr:A3 `6�S'07 MR'ARICNS 0 YARD IN'.FT 9 P.OI).4RD c(), VrJTY m s 0 ORO:LEF 8 -1-0 FUG. }— OJY Ws^E '17 F>FCIRtG YETAii CA?AT.CRMIDx.m �•+---d U?W^.'Pou A/Lwy U,GAS Uc M M M42 U`JIT PmE !'A WATER mmp VA-15.MA.SJNNY 9GM GAS VA w- PLAT.PIATrml --�+—P\C FENCE(PVC) wW.Y0A"Y"8 N'Eit. __L... MvAC%'FE!iCE{^�Yl `�"N'M1 ICR Yd:V.: W IL W'.SDO'R —1c—cmA il.F'EHCE(,,-I tl MZT,RAW.., C/t'MVIRR EMRAYIX -. Wt1E FENLE R/O Rm Ok R (�� fIRE nYJZA� O.C.0Fres,3.D CURB A/C UN" . 4�L"SS i7;T C.O.L.CENMLkIT 0 LINE' r S1ARE O/L.04 L4E R.U.W.MPHT V WAY ... 1 �� Ai°�a1F° Gq ;•\'/CFI it 1 I o w k a sf ley U ir'ewoor 84.V \ a U QDi \ ro J o I i0®r 1 I o OI w�t ill "A4 Pp h. liA^:,PAY(SI I O PAS Wr 48 r 1 'dbj b q µ ;urdrxG raa Ra 1O �. 11N + � / '" /,•5 w} V 37 a® 90 s P r u` F a- •�qb / nr n 187.18' ,.v t —S88*59'00.1I s I1O1 mF°'1 �J� I I I PISIOP44.1 nyt g ll �Ad I v OpECHET A V.EA 'W"DONED L' (88' Irmr) GRAPHIC SCALE LOT AREA 30 0 15 M 24,36255 SF. *ALL ELEVATIONS REFER TO NAVD88'DATUM ass AC r 1 inch= 30 it i 1 �{4 07 202?W'cT" NC ACS ADCED 1'C JTS REV L`/aT� IUt.,C u'P7i`",d � 6Y CHY SCALICE 2NO M SURVEY OF PROPERTY INNFJIAHA BOULEVARD,SOUTHOLD. New York 11971 -_ - land surveying SITUATE SOUTHOLD, TOWN OF SOUTHOLD _ mjslandsurvey.com P:631-957-2400 SUFFOLK COUNTY, NEW YORK 2- - 1 South Bay Avenue, Islip, NY 11751 DR.:MC CRLW.:,F SCALE:1'-30• TAX MAP NO. DATE SURVEYED:07/01/2022 JOB N0.S22-2365 10OG-087.00-03.00-043.000 ('�ienl"vxm.�i. .Mvw�:cen uw iw ry .,. an'rr�awv,n:+eena+. .. h c,) ,uvon xsr.. e+sn edewx caz -roes a..vnc tt :r x m m N 'sue _ m �r r'x aT Y w'Ntl taCfaK.-NiFSYC�W1 Eta:'ut�"s n �IeYGLK NOTES, i�ROJEGT SLOP : :PROJECT/ZONIN6 •TrA - � g 1.TNIS IS AN AVMFI ATI SITE PLAN!IS 6° Z S19.EGT TO VERIFlCATION BT'A LICENSED TAX MAP O 1000-ST-�49 SURVEYOR T/✓E IFIFOFAtATION REPRC�ENIED oN TNIS 5Ire PLAN Is To THE - PROF. ADDITIONS TO FRONT OF HOME W/NEW ROOF, EXTENDED ARGHITEGT5 BES7 OP ITI�h'LEDEE. .A_* ZANINS DISTRICT s SURVEY INFORMATION P05 OsrANEO COVERED PORCH, 8 2ND FLOOR OVER PORT. OF EXIST. HOME_ LOT AREA 0..6 ACRES Plot FROM ASJRVEYVATED O7/0I/2022 - PROPOSED REBUILT REAR OPEN PATIO WITH NEW OUTDOOR EIBQ �= M QROP05ED REAR ADDITION. eoro-ONE FAMILY DMELLIN6 z-t2sev2 y o9na62 0 .s �W� - PROPOSED DRYWELL5 VARIANCE APPROVAL 15LIP FLY.Ir151 FEMA FLOOD ZONE AE(6')/A/X i=a 6 g e * Aft'&WUSTEE -TO.WN'OF SOUTHOLD kETIANDSDISTRICT PENOING 1R.-I DEG DISTRICT PENDM6 2 W N F EXISTING 5EPTIC SYSTEM ESE:g� II DATE T�-e1� G rJ r1A1 �_o AT EXIST.METAL RAMP TO REMAIN A5 15 - E � �F$ LOT DE55AIFTION(FOOTPRINT) AREA S � 04'00"W %ovERAEE D GK S19° €s ��"25,1•g' TOTAL LOT AREA(9UILDAE E LAND) 209156 S.F. 0"E �' � 3 O 41ATGHED AREA INDICATES. ./" 15'NON-TURF SUFFER �� C�' EXIsnNG ONE STORY PPELLINS 24595 Ilb% 5.3.26�- �_— , C?\�a'' , �•(` EXISTING REAR COVERED PATIO 4515 22% .000 Gp 6` ZONE A �" Z S'!� fr. •-\ EXIsnNO SHED 89.6 0.4% g0 —T•V•\O• / , _,., p a ' = p`' .' CT EXISTING OUTDOOR SNOPER 34 0.2% rlyl OG�C �r iir i / Lf/-�KETLANDS BOUNDARY ' PROP.FRONT ADDITION(ENTRY) n6 0." � Z3 P / / / i ' FOLLOW5 RET.WALL 4--' — g6.5�./ N N\6N_ h , m �j ¢ PROP.FRONT ADDITION(GARAGE) 240 13% U � , ON REST OF SITE 3 9� 740y O � m / , / / , � _n1 PROP.COVERED FRONT PORCH '69'I o3% -xi Cl,' ' W ApPROXLIMI ACTION �Q V"� MOD.COVERED FRONT 151 Ob% }� -� ` NG• r-, / i ,PAVE n �: ____ o 'nTe r+iv`E F yV G -� PROP.REBUILT RAISED PATIO f T41 95% end , , LIMITS OF GLEARIN5, W\ to•' i // , / / P 741 �4e✓%i PROP.REAR ADDITION 85:1 OA% () C M GRADINS,AND GROUND O 'i, ,� i .• F- DISTURBANCE TOTAL AREA OF ALL STRUCTURES 4466,0 S.F. 21A% '1"• , uJ 1 EXIST.3'POST 6 Q �r i , RAIL FENCE -MAXIMUM LOT COVERAGE AUOr� 20% O " ' O��_ � .R�EGU1�Dt5ETBAG�Y.S MAfNgI�ICDIN6µ'�.��Y ��.. ,.a ,,.•... ... . .. a PRO1 1.8'm� o PROP STEPS •Ns o •\ �I , �O_f REOVIRID EXIST. PROPOSED fAt�LIES DRYlNELL EX.HURIED �' PROP. - 1 1 EXIST.WD.FR.SHED I GAS\TANKI l 57EP54 2 FLOGO FRONT YARD 40 0' 90v' 6A' NARA ID, 255' 35.1 ? pL GNN�e SIDE YARD 5A' YIO' ITO' YES N EXIST. C\�MOD.RA�5ED � O ao SIDE YARDS 95D' 970' 99.1' YE5 •� �•\�5,p, a_ GOV. b-I PATIP-6 KI - - P- PIERLINE � PATIO BCi \b�' PRO .REAR 2- ' YARD SOO' 645' 64.5' YE5 �uFEB STORY ADD. FE2 O 2025 • ARIANGE NEEDED FOR FRONT YARD SETBACK" A5-BUILT 5HOWER t _ ,, Rl pl RELOCATED �GI5'f:lI STRY _ y I C GENERATOR(2k4') \ /.�N1D. DEWLLINS s3 AS-BUILT A/C I 1---��oldTown E550 'S7RUCTV�2ERE[3UI,R tyT`5-•E� r,`�5 a a_ -� 100'LINE FROM - 1—id'"°""` CONDENSER(2'x2') 803No1TNstEFS EXIST. PROPOSED COMPLIES dS E WNE FIZOS \\ IB.3' ,/ PROP.FENCE _ ASA, 1 PROP.ORAV.WALK MAXIMUM NEISNT W 10' ID' YE5 0. o z PROP.FENCE I@, a %r LIKE OF REMOVED DRIVEWAY NO p 0 G 5` RfUJP.GDV. '- ? MINIMUM SIDE 1O 0• 12' 12' NARIANCE " p o �1' i,PROP.I 5TR 7.2" PROP.2ND YARD REOI s a R H EXIST.V POST 8 j FRONT ADD.4 FRANT PORG4i_ MI p1Nr m STORY ABOVE RAIL FENCE -� VESTImf.F MOD• �• EXIST.HOME Yw REAR OA' IOSb' IOSb' YEs o z 0• (ATTIC) VARIANCE NEEDED FOR ACCESSORY SIDE YARD SETBACK o i EXIST. ? d I�z I�CSC: Is Q O.H.WIRE =s�-�" �- 50UTHOLD Tq C-.ODP 280 30T( (aT _ _ 07°13'00"E 60.00 N16 35 OEx" - ALLOKABLE TOTAL PROP.2"-5) �Q •. 60,00' LOT 517E/AREA IN 20,019b S.F. 919.6 SF. GPA GFA CALIPER TREES(3) EXCESS of 20,000 sU M I N N E'+i A H A B.L- V D. (G)LOTS coNTAIwNG UP a MAIL. 0 0 TO 90POO sr. ALLOWABLE PROPOSED 51TE PLAN 10%Or EXCESS LOT AREA 3�SO0 S.F. 91.4 SP. 9p41.4 Sr. 9�002 S.F. o OVER 20POO W v I SCALE,I'-90'-0' � a e • s APPROVED A OCCUPANCY OR s NOTED USE IS UNLAWFUL �E � 6Y: WITHOUT CERTIFICATE NOTIFY BUILDING DEPARTMENTAT OF OCCUPANCY 631-7M1802 8AM TO 413M FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE 2. ROUGH-FRAMING&PLUMBING 3. INSULATION 4. FINAL-CONSTRUCTION MUST COMPLY ALL CODES OF BE COMPLETE FOR C.O.ALL CONSTRUCTION SHALL MEET T NEW YORK STATE�&TOWN CODES THE NEW gEgVIRp AND CONDITION►CIF REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR mmuza DESIGN OR CONSTRUCTON ERRORSmmmumen .--,- 0wwmmm IV&Om FLOW COMPLY Wffm CHAMR 148 P° DMA PREVINTM. RETAIN STORM WATER RUNOFF PURSUANT TO CHAPTER 236 OF THE TOWN CODE, KO H L E R® Models: 20RCA(L.) Multi-Fuel LPG/Natural Gas 09001 standard Features 4 KOHLER. • RDC2 Controller NATIONALLY REGISTERED o One digital controller manages both the generator set and d Y transfer switch functions(with optional Model R)CT). o Electronic speed control responds quickly to varying �;� � �� � demand. o OnCue®Plus Generator Management System for remote monitoring is included with the generator. �#' �� r s �� , ' ' �` • Kohler Command PRO Engine Features o Kohler Command PRO@ OHV engine with hydraulic valve lifters for reliable performance without routine valve adjustment or lengthy break-in requirements. a • Designed for Easy Installation o Sturdy aluminum base can be mounted on gravel or a concrete mounting pad. o Fuel and electrical connections through the enclosure wall The Kohler Advantage eliminate the need for stub-ups through the base. o Customer connection terminal block located near the • High Quality Power controller allows easy access for field wiring. Kohler home generators provide advanced voltage and o Designed for outdoor installation only. frequency regulation along with ultra-low levels of • Certifications harmonic distortion for excellent generator power quality to protect your valuable electronics. o Meets emission regulations for U.S. Environmental Protection Agency(EPA)with both natural gas and LPG. • Extraordinary Reliability o UL 2200/cUL listed(60 Hz model). Kohler is known for extraordinary reliability and o CSA certification available(60 Hz model). performance and backs that up with a premium 5-year or o Accepted by the Massachusetts Board of Registration of 2000 hour limited warranty. Plumbers and Gas Fitters. • Powerful Performance o Meets 181 mph wind rating. Exclusive Powerboost'' technology provides excellent • Approved for stationary standby applications in locations starting power. § served by a reliable utility source. • Aluminum Enclosure • 20RCAL models packaged with a Model RXT automatic o Attractive aluminum enclosure allows installation transfer switch are available. See page 4 and the Model close as 18 inches from your home or small business.t RXT ATS specification sheet. o Enclosure panels can be removed without tools to allow easy access for maintenance and service. • Warranty o 5-year/2000 hour limited warranty for on-grid (standby) applications in locations served by a reliable utility source. Generator Ratings Standby Ratings Line Circuit Natural Gas LPG Breaker Alternator Voltage Phase Hz kW/WA Amps kW/kVA Amps Amps Poles 2F7 1201240 1 60 18/18 75 20/20 :83 100 2 120/208 3 60 17/21 58 17/21 58 70 3 2G7 120/240 3 60 17/21 51 17/21 51 60 3 277/480 3 60 17/21 26 17121 26 30 3 Note: The line circuit breaker is automatically selected based on the generator set model and voltage configuration. RATINGS:Standby ratings apply to installations served by a reliable utility source.All single-phase units are rated at 1.0 powerfactor.The standby rating is applicable to variable loadswith an average load factor of 80%for the duration of the power outage. No overload capacity is specified at this rating. Ratings are in accordance with ISO-3040/1,BS5514,AS2789,and DIN 8271.GENERAL GUIDELINES FOR DERATI NG:ALTITUDE:Derate 4%per305 m(1000 ft.)elevation above 153 m(500 ft.).TEMPERATURE:Derate 2%per 5.5°C(101 F)temperature increase above 10'C(80'F). Availability is subieato change without notice.The generator set manufacturer reserves the right to change the design or spec'rficationswdhout notice and without any obligation or liability whatsoever. Contact your local Kohler Co.generator distributor for availability. § Check the appliance manufacturer's specifications for actual power requirements.Consult a KohlerD Power Systems professional to calculate your exact residential power system requirements. f Meets NFPA guidelines for 18 inch clearance to combustible materials. Check state and local codes for minimum distance required from a structure. G4-272 (20RCA) 9/19c Alternator Specifications Alternator Specifications Alternator Features Specifications Alternator a Compliance with NEMA, IEEE, and ANSI standards for Manufacturer Kohler temperature rise. Type 2-Pole,Rotating Field a Self-ventilated and dripproof construction. Leads,quantity 4 e Windings are vacuum-impregnated with epoxy varnish for 2F7 2G7 4 dependability and long life. Voltage regulator Digital a Superior voltage waveform and minimum harmonic Insulation: NEMA MG1-1.66 distortion from skewed alternator construction. Material Class H e Digital voltage regulator with±1.0% no-load to full-load Temperature rise 130°C Standby RMS regulation. Bearing:quantity,type 1,Sealed a Rotating-field alternator with static exciter for excellent Coupling Direct load response. Amortisseur windings Full a Total harmonic distortion(THD)from no load to full load with Voltage regulation,no-load to full-load RMS t 1.0% a linear load is less than 5%. One-step load acceptance 100%of Rating Peak motor starting kVA: (35%dip for voltages below) 240 V,1 ph 2F7(4 lead) 41 (60 Hz) 240 or 480 V,3 ph 2G7(12 lead) 69(60 Hz) Application Data Engine Exhaust Engine Specifications Exhaust System Manufacturer Kohler Exhaust temperature exiting the Engine:model,type CH1000 4-Cycle enclosure at rated kW,dry,°C(°F) 260(500) Cylinder arrangement V-2 Lubrication Displacement,cm3(cu.in.) 999(61) Bore and stroke,mm(in.) 90 x 78.5(3.54 x 3.1) Lubricating System Type Full Pressure Compression ratio 8,8;1 Main bearings:quantity,type 2,Heavy-Duty Sleeve Oil capacity(with filter),L(qt.)§ 1.9(2.0) Bearings Oil filter:quantity,type§ 1,Cartridge Rated RPM Oil cooler Integral 60 Hz 3600 § Kohler recommends the use of Kohler Genuine oil and fitters. Max.engine power at rated rpm,kW(HP) LPG,60 Hz 23.0(30.9) Fuel Pipe Size Natural gas,60 Hz 20.2(27.1) Minimum Gas Pipe Size Recommendation,in.NPT Cylinder head material Aluminum ® Pipe Length, Natural Gas LPG Valve material Steel/Stellite m(ft.) 281,000 Btu/hr. 340,000 Btu/hr. Piston type and material Aluminum Alloy Crankshaft material Heat Treated,Ductile Iron 8 ( 1 3/4 50) 1 1 ) Governor:type Electronic 15 (0 Frequency regulation,no load to full load Isochronous 30 (10) 1 1/4 1 Frequency regulation,steady state t0.5'k 46 (150) 1 1/4 1 1/4 A 61 (200) 1 1/4 1 1/4 Air cleaner type Dry Engine Electrical Engine Electrical System Ignition system Electronic, Capacitive Discharge Starter motor rated voltage(DC) 12 Battery(purchased separately): Ground Negative Volts(DC) 12 Battery quantity 1 Recommended cold cranking amps: (CCA) rating for-18°C(01F) 500 Group size 51 G4-272 (20RCA) 9/19c Fuel,Requirements RDC2 Controller Features, Continued Fuel System • LED indicators for utility power and generator set source Fuel types Natural Gas or LPG availability and ATS position (Model RXT transfer switch Fuel supply inlet 112 NPT required) . Fuel supply pressure,kPa(in.H20): • LCD display: Natural gas 0.9-2.7(3.5-11) o Two lines x 16 characters per line LP 1.7-2.7(7-11) o Backlit display with adjustable contrast for excellent Fuel Composition Limits* Nat.Gas LPG visibility in all lighting conditions Methane,%by volume(minimum) 90 min. — • Scrolling system status display: Ethane,%by volume(maximum) 4.0 max. — o Generator set status Propane,%by volume 1.0 max. 85 min. o Voltage and frequency Propene,%by volume(maximum) 0.1 max. 5.0 max. o Engine temperature C4 and higher,%by volume 0.3 max. 2.5 max. o Oil pressure Sulfur,ppm mass(maximum) 25 max. o Battery voltage Lower heating value, o Engine runtime hours MJ/m3(Btu/ft3),(minimum) 33.2(890) 84.2(2260)• • Date and time displays * Contact your local distributor for suitability and rating derates based • Smart engine cooldown senses engine temperature on fuel compositions outside these limits. • Digital isochronous governor maintains steady-state speed at all loads Operation Requirements • Digital voltage regulation: ±1.0%RMS no-load to full-load Fuel Consumption,m3/hr.(cfh)@ 6OHz • Automatic start with programmed cranking cycle %Load Natural Gas LPG • Programmable exerciser can be set to start automatically on 100 8.0 (281) 3.9 (136) any future day and time, and run every week or every two 75 6.9 (243) 3.1 (109) weeks 50 4.6 (161) 2.3 (82) • Exercise modes: 25 3.6 (127) 1.7 (59) o Unloaded weekly exercise with complete system Exercise 2.0 (71) 1.0 (35) diagnostics Nominal fuel rating: Natural gas: 37 MJ/m3(1000 Btu/ft.3) o Unloaded full-speed exercise LPG: 93 MJ/m3(2500 Btufft.3) o Loaded full-speed exercise(Model RXT ATS required) LPG conversion factors: 8.58 ft.3=1 lb. • Front-access mini USB connector for SiteTech- or USB 0.535 m3=1 kg Utility connection 36.39 ft 3 =1 gal. • Integral Ethernet connector for Kohler®OnCue@ Plus Generator Set Sound Data • Built-in 2.5 amp battery charger • Remote two-wire start/stop capability for optional connection Model 20RCA 8 point logarithmic average sound levels are of a Model RDT transfer switch 64 dB(A) during weekly engine exercise and 69 dB(A)during • Diagnostic messages: Displays diagnostic messages for the full-speed generator diagnostics and normal operation.* engine, generator, Model RXT transfer switch,programmable All sound levels are measured at 7 meters with no load. interface module(PIM),and load management device. • Maintenance reminders * Lowest of 8 points measured around the generator. Sound levels at other points around generator may vary depending on installation • System settings: parameters. o System voltage,frequency,and phase RDC2 Controller o Voltage adjustment o Measurement system, English or metric • ATS status(Model RXT ATS required): o Source availability Voltage: 240V o ATS position(normal/utility or emergency/generator) F'q: 60.0Hz o Source voltage and frequency i OR o ®®® ® • ATS control(Model RXT ATS required): o Source voltage and frequency settings ® CW AM "" o Engine start time delay o Transfer time delays o Voltage calibration The RDC2 controller provides integrated control for the o Fixed pickup and dropout settings generator set, Kohler@ Model RXT transfer switch, • Programmable Interface Module(PIM)status displays: programmable interface module(PIM), and load shed kit. o Input status(active/inactive) o Output status (active/inactive) RDC2 Controller Features • Load control menus: • Membrane keypad: o Load status o OFF,AUTO, and RUN pushbuttons o Test function o Select and arrow buttons for access to system configuration and adjustment menus • LED indicators for OFF,AUTO, and RUN modes G4272 (20RCA) 9/19c i K�►HLER® PhoneKOHL 9 CO.,Kohler,Wisconsin 9-164 USA Phone 920-457-4441,Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada,phone 1-800-544-2444 KOHLERPoweccom Generator Set Standard Features Automatic Transfer Switches and Accessories • Battery cables ❑ Model RDT ATS • EPA certified fuel system ❑ Model RXT ATS • Aluminum sound enclosure ❑ Model RXT ATS with combined interface/load management board • Critical silencer ❑ Load shed kit for RXT or RDT • Field-connection terminal block ❑ Power relay modules(use up to 4 relay modules for • Fuel solenoid valve and secondary regulator each load management device) • Line circuit breaker ❑ Other Kohler®ATS • Multi-fuel system, LPG/natural gas,field-convertible 20RCAL Model Packages • Oil drain extension with shutoff valve ❑ 20RCAL with 100 amp RXT with 16-space load center and • OnCue®Plus Generator Management System NEMA 1 steel enclosure for indoor installation • Premium 5-year limited warranty ❑ 20RCAL with 200 amp service entrance-rated Model RXT • RDC2 generator set/ATS controller with combined interface/load management board and • Rodent-resistant construction corrosion-resistant NEMA 3R aluminum enclosure • Sound-deadening,flame-retardant foam per UL 94, Warranty class HF-1 ❑ 5-Year Comprehensive Limited Warranty Available Options ❑ 10-Year Comprehensive Limited Warranty Approvals and Listings ❑ CSA approval Concrete Mounting Pads ❑ Concrete mounting pad, 3 in.thick ❑ Concrete mounting pad,4 in.thick (recommended for storm-prone areas) Electrical Accessories ❑ Battery ❑ Battery heater, 120VAC ❑ Battery heater,240VAC ❑ Cold weather package, 120VAC Generator Set Dimensions and Weights ❑ Cold weather package,240VAC Emergency stop kit Generator Set Size,L x W x H: 1193 x 666 x 817 mm ❑ g y p (47 x 26.2 x 32.2 in.) ❑ PowerSync®Automatic Paralleling Module(APM) (single phase only; parallel two 20kW residential generator Shipping Weights: sets with the RDC2 controller) 20RCA Generator Set: 252 kg(555 lb.) Programmable interface module PIM 20RCAL with 100 A RXT ATS w/LC 277 kg(611 lbs.) ❑ 9 ( ) 20RCAL with 200 A RXT SE ATS: 272 kg(600 lb.) (provides 2 digital inputs and 6 relay outputs) f, L Fuel System Accessories ❑ Flexible fuel line(included on CIS models) ❑ Carburetor heater, 120 VAC ❑ Carburetor heater,240 VAC H t!w Carburetor heater is recommended for reliable starting at temperatures below 0'C(321F) Literature ❑ General maintenance literature kit I. W--I ❑ Overhaul literature kit NOTE:Dimensions are provided for reference only and should not be used for planning ❑ Production literature kit installation.Contactyourlocaldisthbutorformore detailed infomration. Maintenance DISTRIBUTED BY- ❑ Maintenance kit(includes air filter, oil, oil filteri and spark plugs) ©2018,2019 by Kohler Co. All rights reserved. G4-272 (20RCA) 9/19c