Loading...
HomeMy WebLinkAbout52300-Z ho�soF soulyo`o Town of Southold P.O. Box 1179 c 53095 Main Rd Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46717 Date: 12/09/2025 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1105 Mill Rd Peconic, NY 1,1958 Sec/Block/Lot: 74.-2-10.5 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 08/18/2025 Pursuant to which Building Permit No. 52300 and dated: 09/25/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof-mounted solar panels on an existing single-family dwelling as applied for. The certificate is issued to: Craig Fredricks ,Jessica Fredricks Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 113816 10/18/2025 PLUMBERS CERTIFICATION: V" D�1' — A thori d Signa ofSoury TOWN OF SOUTHOLD BUILDING DEPARTMENT • TOWN CLERK'S OFFICE ,o SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52300 Date: 09/25/2025 Permission is hereby granted to: Craig Fredricks 715 Cottage Way Mattituck, NY 11952 To: install roof-mounted solar panels on an existing single-family dwelling as applied for. Premises Located at: 1105 Mill Rd, Peconic, NY 11958 SCTM#74.-2-10.5 Pursuant to application dated 08/18/2025 and approved by the Building Inspector. To expire on 09/25/2027. Contractors: Required Inspections: Fees: SOLAR PANELS $100.00 CO-RESIDENTIAL $100.00 Total S200.00 wilding Inspector ` GG NASSAU ELECTRICAL)INO 1 4 20 ! : S U F F 0 L K INSPECTORS` 25 I 159 Route 25A, Building 1 Suite B " Miller Place, NY 11764 Telephone:631 495 8136 ? Fax:631 509 4538 ? E-Mail: Requests@SuffolkBEI.com CERTIFICATE OF ELECTRICAL COMPLIANCE Applicant: Element Energy LLC Certificate No.: 113816 Rough In Inspection Date: Final Inspection Date: Oct 28,2025 Application No.: 9644018102 Building Permit No.: 52300 County Tax Map No.: 1000 074.00 02.00 010.005 LIPA Solar App No.: PAM-2025-392082 This Certificate of Electrical Compliance is limited to the inspection and compliance of electrical equipment and/or work described below, installed on behalf of the applicant named above, located at the premise of and not after the final inspection date above: Owner: CRAIG FREDRICKS Site Location: 1105 MILL ROAD,PECONIC,NY 11958 Owner's Address(if different): �x Residential �x Indoor Basement Service Shed ❑Commercial �x Outdoor First Floor Pool Hottub ❑New Renovation ❑Second Floor ❑Attic/3rd Floor Garage ❑Addition ❑Survey Qx PV Solar Generator Conversion Signs Battery Storage Other: INVENTORY Single Phase Heat Duplex Recpt Ceiling Fixture Dual Func Breaker Three Phase Hot Water GFCI Recpt Wall Fixture Smoke Main Panel AC Cond Single Recpt Recessed Fixture CO Detect Sub Panel AC Blower Range Recpt� LED Lighting Smoke CO Combo Transformer Appliance CktO Dryer Recpt� Emergency Time ClockO Disconnect�l Switches Twist Lock Exit Fixtures Pumps GFCI Breaker Heat Pump Electric Heat O PoolLuminaire� Exhaust Fan Other Equipment:System Size:18.7 kW Qty:44 Desc:EAGLE JINKO JKM425N-54HL4-B Qry:44 Desc:Enphase I08MC-72-M-US r The electrical work and/or equipment described above were inspected and was found to be in compliance with local, state and national electrical code requirements and this office. Applicant: Element Energy LLC License No.: 52689-ME Date Printed: Oct 29, 2025 Inspected I / Signature: `�/y �O�aOF SO(¢,�°� .y ro # TOWN OF SOUTHOLD BUILDING DEPT. . 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/REBAR [ ] .ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /.STRAPPING [A-fINAL ( ] FIREPLACE & CHIMNEY [ ]' FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ]. ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION . [ ] PRE C/O [ ] RENTAL REMARKS: DATE %?-/'o?5 INSPECTOR W&SSLING 0NSU1,nNQA 768orth Meadowbrook Drive Scott ENysufing, PE Alpine, UT84004 Heath lHmqooher, PE, PEng office(2D1) 874-3483 Gregory TBveabadPE awysmlinQ@wysudingcunuulting.nom �� � October 21. 2D25 ! / U� Ky �= U \� �� 1 � �0�� | �� ~ = Nov''` ' ' ` �"�^ L�7 Element Energy LLC 7470Gound Avenue, K8attituuk. NY. 11852 "J�```� � Re: Engineering Services (Post-Install) Fredricks Residence 11D5 Mill Lane, Pmnonic, NY 1O7OOkVVSystem ' --~ To Whom It May Concern: puneuord to your request, we have reviewed the installation of the abova-nahananuad solar panel system. As you are aware,this office initially prepared a structural assessment, dated August 18, 2025, of the solar panel installation. This installation was inspected and'found to be in compliance with the layout plan as specified in our report, product installation criteria, and the requirements of the current building code. We have determined that the equipment will not create a negative impact on the building's structural design, including any additional loads imposed (dead, snow, wind). This letter pertains only to the panel support attachments to the roof framing and not the engineered photovoltaic panel produuta, uomponanta, or electrical-related installations/connections. Should you have any questions regarding the above or if you require additional information do not hesitate ba contact me. V truly yours ­N1 Scott E. ssli PE WY New York License N 3 Itwo Violation of the law for any person,unless acting under the direction muucenmom � professional,to atter an item m any Way.nan item bearing to m aLm licensed professional 'is altered,the altering licensed professional shall unix�m their xvmmm,.00at Emdu,*vomuon Signed 10/21/2025 "altered hy"muowvd6v their signature and the Expires 7/31/2027 uatp/x such alteration,and uspecific description oxmheuuvmunn. ' FIELD INSPECTION REPORT DATET— COMMENTS kivo FOUNDATION (1ST) -------------------------------------- FOUNDATION (2ND) —------ O ROUGH FRAMING& PLUMBING INSULATION PER N. Y. STATE ENERGY CODE FINAL ------------ ADDITIONAL COMMENTS (N- o rn ILA X (-Nx -------------- ......-------- I TOWN OF SOUTHO LD—]BUILDING DEPARTMENT I y2 Town Hall Annex 54375 Main Load P. ®. Box 1179 Southold, NY 11971-0959 I lei as Telephone (631) 765-1802 Fax(631) 765-9502 https:/wwtiv.southoldtownny.�ov i Date Received APPLICATION FOR BUILDING PERMIT � For Office Use Only E C E E i D i PERMIT NO. 5OU66 Building Inspector: AUG 1 9 2025 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an Building Department Owner's Authorization forums(Page 2)shall be completed. Town of Southold i ®ate: OWNER(S)OF PROPERTY- � Name: Project Address: C W1�'� kU /\). /. Phone#: C 3 a_ 2 - 7 0 L' I mail: �l9b�D--� 9'S c5<Co 01 Mailing Address: 5 mill H0` pew vG N q. l/ l 5f CONTACT PERSON- Name: Lo p'-"DrA-i'nf �- Mailing Address: -7 47® cS o LAA d akl M 4-4-4 — -. -D k °` v. )t cl,5 IPhone#: (o 3 I 3 9 2 �7 0 q / Email: 4,5 e- C, S , cok,-, j DESIGN PROFESSIONAL INFORMATIOM. Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION.- Name: Mailing Address: All Phone#: v 3 g D 4 ) Email: DESCRIPTION OF PROPOSED CoNsTRucrioN []New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: they -Sb IeL r PV S4-e i $ � I Will the lot be re-graded? ❑YesXNo Will excess fill be removed from premises? ❑Yes\5610 j � I 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which is situated: Are there any covenants and restrictions with respect to this property? OYN IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water Issues as provided by er 286 of the Town Code.APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone dinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section WAS of the New York State Penal taw. Application Submitted L rraine DiPenta PP B Y(print )name : BAuthorized Agent ❑Owner Signature of Applicant: ��� � Date: STATE OF NEW YORK) b l SS: COUNTY OF Suffolk ) Lorraine DiPenta being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me thi Sdayof, ('`—� 20'--S ota lic OMEO YotK . PROPERTY OWNER AUTHORIZATION VO - sateotNeW ` Puplia, 0631403untY (Where the applicant is not the owner) N°t`ry 0o•et�su'�Oly C° 17 24 Qua%jed in►es November t � r l� .Comm►ss►on�p I, eSS FC-cg- r°G 5 residing at 1 1 ��e i Iv �• �L-`Sgdo hereby authorize Lo rou'ac, L � A to apply I on my b If to the Town of Southold Building Department for approval as described herein. �C Owner's Signature Date Print Owner's Name 2 VVYSSLING CONSULTING • •• -- 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, LIT 84004 Heath J. Harpster, PE, P.Eng office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com August 17, 2025 Element Energy LLC 7470 Sound Avenue, Mattituck, NY, 11952 Re: Engineering Services Fredricks Residence 1105 Mill Lane, Peconic, NY 18.700 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: 2x8 dimensional lumber spaced at 16" on center. Roof Material. Composite Asphalt Shingles Roof Slope: 30 degrees Attic Access: Accessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing = 8 psf o New Solar Panels and Racking = 3 psf o TOTAL= 11 PSF • Live Load =20 psf(reducible)—0 psf at locations of solar panels • Ground Snow Load = 25 psf o Wind Load based on ASCE 7-16 o Ultimate Wind Speed = 134 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2020 NYS Residential Code (2018 IRC). This analysis indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent IronRidge installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a#14 lag screw is 194 Ibs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on two screws with a minimum penetration depth of 2",the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using two# 14 lag screws with a minimum of 2" embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of rafters, and condition of the roof, the panel supports shall be placed no greater than 48" on center. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2020 NYS Residential Code (2018 IRC), current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. V truly yOoursVA, It Is a violation of the law for a nyperson,unless Scott E. Wyssli PE acting under the direction of.a licensed NY PE License No. NY COA#022082 :professional,to alter an item in any way.If an item bearing the seal of a licensed professional is a ltered,the altering licensed professional s hall affix to their item thei r.seal and the notation "altered by"followed by their signaturib and the date of such alteration.,and a specific description of the alteration. co ri � q �;•,t�r �r f t�� I•N s �4 it � S I llllysslingl Consulting, PLLC 76 N. Meadow brook Drive;Aip�ine UT New York COA#0022571 Signed 8/17/2025 Expires 7/31/2027 W&O SSLING NSUL? G CONTRACTOR JESSICA FREDRICKS ELEMENT d El IN ENERGY BOLARIBATTERY BACKUP1631.779.791331E25Y5.COM AHJ UTILITY SCOPE OF WORK VICINITY MAP ELEMENT ENERGY LLC TOWN OF SOUTHOLD LONG ISLAND POWER AUTHORITY (N) 18.700KW DC/14.080KW AC ROOF MOUNTED PV SYSTEM 7470 SOUND AVE, (44)JINKO SOLAR JKM425N-54HL4-B MODULES _== MATTITUCK, NY 11952, USA (44) ENPHASE IQ8MC-72-M-US (240V) MICROINVERTERS - +1 631 760 7262 (01) ENPHASE IQ 5/5C COMBINER PANEL `':: ', LIC TYPE: HOME CODES AND STANDARDS WITH AMENDMENTS _- IMPROVEMENT, MASTER 2020 BCNYS r ." _ ELECTRICIAN LIC NO.: 67461-HI,52689-ME 2020 FCNYS 2020 RCNYSj 2017 NEC 1105 Mill Ln, /�"f PROJECT INFO&ADDRESS Peconic,NY 11958, f` JESSICA FREDRICKS ~ ,y� United States 1105 MILL LN, ENVIRONMENTAL ap f;' PECONIC, WIND SPEED: 134 MPH .0 r NY 11958, USA SNOW LOAD: 25 PSFSYSTEM SIZE EXPOSURE CATEGORY: C DC SIZE: 18.700 KW DC-(STC) AC SIZE: 14.080 KW AC GENERAL NOTES 'it is.evioLationofthelawforany person,un SHEET INDEX actingunderthedirect"ionofalicen ed PROJECT NOTES: p€ofessionaL-to-atteranitem inanylay".'ffari -THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE PV-1 COVER SHEET item bearing;;The-seslofA censedprfessionai NATIONAL ELECTRIC CODERTICLE 690,ALL METER NO: 80424564 I (NEC)( ) PV-2 SITE PLAN-1 is altered;the altering.lirensed prafjssiana'L sha[!. MANUFACTURER'S LISTING AND INSTALLATION INSTRUCTIONS, PV-2.1 SITE PLAN-2 affix-to the!r item thelrsealandthe 'otation AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY PV-3 ATTACHMENT PLAN altered Wfo[tQwipd bytheirslgnat reendthe HAVING JURISDICTION'S (AHJ)APPLICABLE CODES. �P 0 D AS NOTED PV-3.1 STRUCTURAL PLAN ,dple of-such,aLterstian,and.a specific -THE UTILITY INTERCONNECTION APPLICATION MUST BE t'i �j PV-4 ELECTRICAL •descriptianafthealteration. �'� �,}��r � APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL D P.• vlJv PV-4.1 ELECTRICAL CALCULATIONS co OPERATION GROUND GFDI D FAULT DETECTION AND INTERRUPTION PV-5 LABELS ( ) FEE ° � PV-6 RESOURCE DOCUMENT IF E��TR�C/�. DEVICE IS INTEGRATED WITH THE MICRO INVERTERS IN NOTYBUILDINGDEPARTMENTAT r7 �•.a 631-765-1802 8AMT04PMFORTHE INSPECTION REQUIRED PV-6.1 RESOURCE DOCUMENT ACCORDANCE WITH NEC 690.41(B) PV-6.2 RESOURCE DOCUMENT [-, ,A -ALL PV SYSTEM COMPONENTS; MODULES,. FOLLOWING INSPECTIONS: I PV-6.3 RESOURCE DOCUMENT UTILITY-INTERACTIVE INVERTERS,AND SOURCE CIRCUIT I. FOUNDATION-TWO REQUIRED PV-6.4 RESOURCE DOCUMENT �`` COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN FOR POURED CONCRETE' ti{;� 3D" 2. ROUGH-FRAMING&PLUMBING PV-6.5 RESOURCE DOCUMENT + , ?r PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4: PV PV-6.6 RESOURCE DOCUMENT �_� MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 3. INSULATION PV-6.7 RESOURCE DOCUMENT CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, 4. FINAL-CONSTRUCTION MUST PV-6.8 RESOURCE DOCUMENT ysslin Consulting, PL.LC 519 COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY BE COMPLETE FOR C.O. 7� Mead.owbroak Drive,Alpine U ALL CONSTRUCTION SHALL MEET THE New York'COA#0022571 -MAX DC VOLTAGE CALCULATED USING MANUFACTURER REQUIREMENTS OF THE CODES OF NEW COMPLYCODESSigned 8/17/2025 PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX YORK STATE. NOT RESPONSIBLE FOR NEW Y©Rff SWTgTE�; DE DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7. S Expires 7/31/2027 -ALL INVERTERS, PHOTOVOLTAIC MODULES,PHOTOVOLTAIC DESIGN OR CONSTRUCTON ERRORS AS REQUIRED AND CONDITIONS OF PANELS, AND SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED VHD zm DRAWN BY SP AND LISTED FOR THE APPLICATION PER 690.4. SHALL BEGBQ } DATE 8/14/2025 INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OCCUPANCY OR r�uss REVISION OR LABELING [NEC 110.31. �c� IS ���1A/F��-ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL VV V �r SIGNATURE BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS WITHOUT CERTIFICATE PV-1 REQUIRED BY THE NEC AND AHJ. OF OCCUPANCY COVER SHEET CONTRACTOR SCOPE OF WORK (N) 18.700KW DC/14.080KW AC ROOF MOUNTED PV SYSTEM TOTAL ROOF SQUARE FOOTAGE IS:2913.09 FTZ ELEMENT (a44)JINKO SOLAR JKM425N-54HL4-B MODULES NEW ARRAY SQUARE FOOTAGE IS: 924.85 FTZ COVERED BY SOLAR IS: 31.75% d Elul ENERGY (44) ENPHASE IQ8MC-72-M-US (240V) MICROINVERTERS SOLARI BATTERY BACKUP 1631.779.79931E25YB,COM (01) ENPHASE IQ 5/5C COMBINER PANEL ELEMENT ENERGY LLC 7470 SOUND AVE, Ott C/v MATTITUCK 760 7262 11952, USA +1 631LIC TYPE: HOME IMPROVEMENT, MASTER -0>6f ELECTRICIAN LIC NO.: 67461-HI, 52689-ME PROJECT INFO&ADDRESS / JESSICA FREDRICKS / 1105 MILL LN, O PECONIC, 00 � (E) NON HABITABLE ry / NY 11958, USA �� GROUP U STRUCTURE � 2I9r, / � SYSTEM SIZE DC SIZE: 18.700 KW -(STC) AC SIZE: 14.080 KW AC �03 \ Q It is a vintstioit c>f fhs l 3w fora. er-son,unless �� / of / nY P g acttngtindertiie+iireetlonafa Licensed Cb -I-/ professiosa al to titter an.�tem 1n any.way.t(:a iterni aringthe'sealofAlicensedprofessio sl (E) POOL is aYtered the altennglicensed profession[ halt. / �• affix"ta>Lii�ei�itemtheir.seaLand-fle:notatior9 / ��/ "altsrccl by"faUovved b}�fhelr s'sgnature and the �-,�* �;� �h dateofsucha9tetatron;andasecific � / +description of the-atterstion. / 4 .,{ Ij (E) NON HABITABLE GROUP U STRUCTURE Wyssfi11g Co's49iting, PLLC: (E) MAIN HOUSE / 76 N.Meeadowbrook Drive,,.Alpirle U LEGEND 89,1 \ / New YorkCITA:.#0022571 ®FIRE PATHWAYS Signed 8/17/2025 PROPERTY LINE Expires 7/31/2027 o FENCE DRAWN BY SIP ® SKYLIGHT/CHIMNEY DATE 8/14/2025 O ❑ VENT/OBSTRUCTION REVISION SIGNATURE SITE PLANA PV' -2 SCALE:1/64"=1'-0" SITE PLAN-1 _SCOPE OF WORK (N) 18.700KW DC/14.080KW AC ROOF MOUNTED PV SYSTEM TOTAL ROOF SQUARE FOOTAGE IS:2913.09 NEW ARRAY SQUARE FOOTAGE IS: 924.85 FT 2 CONTRACTOR ELEMENT ENERGY (44)JINKO SOLAR JKM425N-54HL4-B MODULES o (44 ENPHASE IQ8MC-72-M-US 240V MICROINVERTERS L LN COVERED BY SOLAR IS: 31.75/0 ) ( ) � MIL SOLAR IBATTERY BACKUP I631.779.7993IE25Y5.COM (01) ENPHASE IQ 5/5C COMBINER PANEL (N)ENPHASE IQ 5/5C COMBINER PANEL (N)VISIBLE LOCKABLE LABELED WITH ENPHASE IQ GATEWAY AND FUSED AC DISCONNECT ELEMENT ENERGY LLC (OUTSIDE GARAGE) (UTILITY DISCONNECT) 7470 SOUND AVE, (N)CONDUIT RUN (OUTSIDE GARAGE) MATTITUCK, NY 11952, USA +1 631 760 7262 3'-o" CB ACD LADDER ACCESS LIC TYPE: HOME uM IMPROVEMENT, MASTER ELECTRICIAN C) LIC NO.: 67461-HI, 52689-ME M (E)MAIN SERVICE PANEL PROJECT INFO 8 ADDRESS (INSIDE BASEMENT) (E) UTILITY METER JESSICA FREDRICKS (OVERHEAD SERVICE) 1105 MILL LN, (POLE MOUNT) PECONIC, NY 11958, USA SYSTEM SIZE DC SIZE: 18.700 KW DC-(STC) CD AC SIZE: 14.080 KW AC M . Itis avloiationofthe faw" forarTypersonj unlets acting.under.thedirection.ofa licensed ;professional,to.alter,anItem n any Way.If'an item bearingtheseat.of a.licensed'professian at is altered;the altering.licensed professional all affixtotheiriterritheir seat.and the notation c' "altered by"followed by their signature and t e date of such alteration,and aspecific 0 0 description of the-alteration. ^ (N) (44)JINKO SOLAR JKM425N-54HL4-B �� MODULES WITH ENPHASE IQ8MC-72-M-US 1� (240V) MICROINVERTERS UNDER EACHti MODULE (240V) ' 1141►yrsslin9 Consulting, P-LLC LEGEND 76 N. I'It1eadowbrook Drive,Alpine U New York COA#0022571 FIRE PATHWAYS Signed 8/17/2025 PROPERTY LINE ' Expires 7/31/2027 M o FENCE DRAWN BY SP ® SKYLIGHT/CHIMNEY O ❑ VENT/OBSTRUCTION DATE 8/14/2025 31-011 REVISION SIGNATURE SITE PLAN-2 PV-2.1 SITE PLAN-2 ROOF SECTIONS) CONTRACTOR ROOF MATERIAL- ® ENERGY 1 " O.C. SPACING- 6 ELEMENT COMPOSITE SHINGLE ROOF 1 RAFTER SIZE- 6 SOLARIBATTERY BACKUP 1631.779.79931EZSYS.COM MODULES-44 ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN LIC NO.: 67461-HI, 52689-ME 4'-0" PROJECT INFO&ADDRESS JESSICA FREDRICKS I I I I I I I I I I I I I I I I I I I I I I I I I 1105 MILL LN, I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 PECONIC, I I T I T I I TI I T I I I I I I NY 11958, USA I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I CV 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 i i SYSTEM SIZE I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I DC SIZE: 18.700 KW DC-(STC) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I AC SIZE: 14.080 KW AC I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 1 1 1 1 1 1 o1 1 1 1 1 1 1 1 1 1 1 I I I I I I I I I I I I I I I I I I I I I I I I I 1 1 1 lyl. 1 1 1 1 1 1 1 1 1 I I 1 1 I I I 1 1 I 1 1 1 1 1 1 1 1 1 1 It i a Violation of the law for any person,un[, ss Is I I I I I I I I I I 1 I I I I I I I I I I I acting,underthe direction ofa Licensed I I I I I I I IT 1 1 T I T I I TI I I I I I I I I I I r I I TI I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 pr fessional.-to=alter an item in anyway Wan I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 0I I I I I I I I I I I I I I I I I I I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 it m:bearingthe sealof a.icensed professio al I. I I I I I is Ltered,:the alteringliaensed professional hall I I I I I 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I ofrix to their item their.seal and'the notation I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I "altered by"followed 6ytheir signature and t e. „ date pfsuch alteration,and specific 1 68-5 � description of the alteration.- CO l'-3" ARRAY 1 3'-8° Y� TILT- 30 DEG AZIMUTH - 273 DEG DEAD LOAD CALCULATION BOM QUANTITY LBS/UNIT TOTAL � � ay, ' WEIGHT(LBS) JINKO SOLAR 44 48.5 2134.00 Wysslinq Consulting, PLLC 0 - CLAMP JKM425N-54HL4-B MODULES N. Meadowhrook:Drive.,Alpine U New York COA#002-2572 • - IRONRIDGE HALO ULTRA GRIP MID-CLAMP 74 0.15 11.10 /17/2025 END-CLAMP 28 0.15 4.20 Signed 8 Expires 7/31/2/31/2027 - IRONRIDGE AIRE Al RAIL LENGTH 30 6.36 190.80 SPLICE BAR 16 0.525 8.40 DRAWN BY SP --------- - RAFTER IRONRIDGE HALO ULTRA 102 0.57 58.14 GRIP DATE 8/14/2025 102 -TOTAL MOUNT ENPHASE IQ8MC-72-M-US 44 2.43 106.92 REVISION (240V) MICROINVERTER SIGNATURE TOTAL WEIGHT OF THE SYSTEM (LBS) 2513.56 1 ATTACHMENT PLAN TOTAL ARRAY AREA ON THE ROOF (SQ.FT) 924.85 PV-3 SCALE:1/8„=V-0" WEIGHT PER SQ.FT. (LBS) 2.31 WEIGHT PER PENETRATION (LBS) 57.13 ATTACHMENT PLAN CONTRACTOR ELEMENT d Ej In ENERGY SOLAR I BATTERY BACKUP 1631,779.79931 E2SYS.COM ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN LIC NO.: 67461-1-1I,52689-ME MODULE BOTTOM MOUNTING CLIP PROJECT INFO&ADDRESS JESSICA FREDRICKS CLAMP w 4" BOLT 1105 MILL LN, AND LOCK WASHER PECONIC, NY 11958, USA JINKO SOLAR JKM425N-54HL4-B MODULE SYSTEM SIZE _ i DC SIZE: 18.700 KW DC-(STC) AC SIZE: 14.080 KW AC IRONRIDGE AIRE Al $" BOLT (E) COMPOSITE SHINGLE i IRONRIDGE QUICKMOUNT HUG (2) #14 x 3" STAINLESS STEEL t,<.� '";r r4; SCREWS, SELF DRILLING SCREW, WITH MINIMUM 2" EMBEDMENT It Is a violation of the law for any person,unless acting under the direction of.a licensed mom' professional,to attar an item in anyway.If an Wyssling Censuulfing, PLLC item bearing the seatof a licensed professional 76 N. Meadowbroek Drive„Alpine U .is altered,the altering licensed professional shall New York COA#0022572 (E) RAFTER 2"X8" @ 16" O.C affix to their item theirseal and the notation Signed 8/17/2025 "altered by"foftwed bytheir signature and the Expires 7/31/2027 date of such alteration,and a specific description ofthealteration. DRAWN BY SP DATE 8/14/2025 REVISION SIGNATURE 1 STRUCTURAL PLAN PV-3.1 SCALE:NTS STRUCTURAL PLAN CONTRACTOR SOLAR MODULE SPECIFICATIONS INVERTER SPECIFICATIONS MANUFACTURER/MODEL# JINKO SOLAR JKM425N-54HL4-B MANUFACTURER/MODEL# ENPHASE IQ8MC-72-M-US(240V) NOTE: ELEMENT � Ej ® ENERGY VMP 32.37V MICROINVERTER _ ALL CONDUCTORS ARE COPPER UNLESS OTHERWISE MIN/MAX DC VOLT RATING 22V MIN/58V MAX NOTED. SOLARI BATTERY BACKUP1631.779.79931 E2SYS.COM IMP 13.13A MAX INPUT POWER 460W VOC 38.95V NOMINAL AC VOLTAGE RATING 240V/211-264V ELEMENT ENERGY LLC ISC 13.58A 7470 SOUND AVE, MAX AC CURRENT 1.33A TUCK, NY 11952, USA TEMP.COEFF.VOC -0.25%/°C MAX MODULES PER STRING 12(SINGLE PHASE) +1 MATTI TTI 760 7262 MODULE DIMENSION 67.79"L x 44.65"W x 1.38"D(In Inch) MAX OUTPUT POWER 320 VA LIC TYPE: HOME IMPROVEMENT, MASTER (4)#12 Q-12-RAW-300 CABLES (N) (1) ENPHASE IQ COMBINER 5/5C ELECTRICIAN WITH ENPHASE IQ GATEWAY, LIC NO.: 67461-HI,52689-ME (N) (44)JINKO SOLAR JKM425N-54HL4-B (4)20A/240VAC CIRCUIT METER NO: 80424564 MODULES BREAKERS, 125A RATED PROJECT INFO&ADDRESS I! 11 MICROINVERTERS IN BRANCH CIRCUIT 1 it I' PER MANUFACTURER (OUTSIDE GARAGE) (N) (1)AC DISCONNECT: SPECIFICATIONS, VISIBLE, LOCKABLE AND LABELED TO UTILITY GRID JESSICA FREDRICKS EITHER 100A FUSED, (2) 80A FUSES, 240V 1105 MILL LN, �i 10A OR 15A OR 20A NEMA 3R, UL LISTED LINE (E) BI-DIRECTIONAL UTILITY �� BREAKER IQ GATEWAY PECONIC, I RIIS SUITABLE FOR USE UTILITY DISCONNECT METER 1-PHASE, 3-W, = I = I I MR LESS ( ) 120V/24OV, 200A RATED NY 11958, USA COMMS L1 (OUTSIDE GARAGE) M L1 (OVERHEAD SERVICE) LOAD (POLE MOUNT) SYSTEM SIZE j 15A/2P N N DC SIZE: 18.700 KW DC-(STC) 11 MICROINVERTERS IN BRANCH CIRCUIT 2 1 .-. _ — SUPPLY SIDE II �' c AC SIZE: 14.080 KW AC � I r--- — � LINE ---1 TAP j =20A/2P zovzP (E) MAIN BREAKER I I 2 I I 2 I TO HOUSE 208 V, 20oA/2P --- I = 1 — I ' I I I I I (TOP FED) I — ~� j— — — — ~IL -L ;'— I I I I � (E) MAIN SERVICE PANEL 1 I I LOAD G o 200A RATED, 240V L -- — 1 I I I I (INSIDE BASEMENT) 20A/2P I I O of L1 " LINE SIDE 11 MICROINVERTERS IN BRANCH CIRCUIT 3 I I �'t r L G INTERCONNECTION a EXISTING AT MAIN PANEL 0 20Al2P I GROUNDING GEC PER ART. �z I ELECTRODE �I II rt . I- y SYSTEM TO EARTH_�_ 705.12(A) REF. NEC 250.52, N Aw 3 N ry0,9 y It is a violsti' of the Law for anyperson,unless °���0-/"� y� � lT �- i� 11 MICROINVERTERS IN BRANCH CIRCUIT I acting licensed i II - . prafe§siol7al,to aUaran'item iri aby way.ii aft tl'IfySSling Consulting, PLLC • I' I item bearing,he seat-of a Licensed professional Mle clowbPo49c QI7v ,_Al ere I 'is atered,-the aLteringticensed professional shall New York #0022572 I — I I affixttlaeiritefntheirsealand the n®tatisn Signed 8/17/2025 '� altered by"fbUoWco lw their signature and the Expires 7/31/2027 date.of si3ch:alteration,'a€Id a speci€ie descfiptionol,the.alteration. DRAWN BY SP (N) (44) ENPHASE IQ8MC-72-M-US PHASE CONDUCTOR QTY,SIZE AND TYPE GROUND CONDUCTOR QTY,SIZE CONDUIT CONDUIT (240V) MICROINVERTERS ONE ID PER CONDUIT NEUTRAL QTY,SIZE AND TYPE PER CONDUIT AND TYPE PER CONDUIT SIZE TYPE DATE 8/14/2025 UNDER EACH MODULE (240V) REVISION 1 4 AWG#12 Q CABLES,THHN NA NA NA 1 AWG#8 BARE,COPPER EGC 3/4" PVC SIGNATURE 2 2 AWG#4 THWN-2,COPPER 1 AWG#4 THWN-2,COPPER 1 AWG#6 THWN-2,COPPER EGC 1" PVC PV-4 E EXSTING CONDUCTOR AND CONDUIT ELECTRICAL CONTRACTOR _ ® ELEMENT ENERGY AMBIENT TEMPERATURE SPECS NUMBER OF CURRENT SOLAR I BATTERY BACKUP 1631.779.79931EZSYS.C°M PERCENT OF VALUES CARRYING CONDUCTORS IN EMT RECORD LOW TEMP -15° ELEMENT ENERGY LLC AMBIENT TEMP (HIGH TEMP 2%) 310 0.80 4-6 7470 SOUND AVE,MATTITUCK, NY 11952, USA CONDUIT HEIGHT 7/8° 0.70 7-9 +1 631 760 7262 ROOF TOP TEMP 530 0.50 10-20 LIC TYPE: HOME IMPROVEMENT, MASTER CONDUCTOR TEMPERATURE RATE 900 ELECTRICIAN LIC NO.: 67461-HI, 52689-ME MODULE TEMPERATURE COEFFICIENT OF Voc -0.25%/°C PROJECT INFO&ADDRESS JESSICA FREDRICKS CALCULATIONS: 1105 MILL LN,PECONIC; NY 11958, USA 1. CURRENT CARRYING CONDUCTOR 2. PV OVER CURRENT PROTECTION SYSTEM SIZE -NEC 690.9(B) DC SIZE: 18.700 KW DC-(STC) (A) BEFORE IQ COMBINER PANEL = TOTAL INVERTER O/P CURRENT x 1.25 AC SIZE: 14.080 KW AC AMBIENT TEMPERATURE - (31)OC ...NEC 310.15(B)(2)(a) = (44 x 1.33) x 1.25 = 73.15 A TEMPERATURE DERATE FACTOR - 0.96 ...NEC 310.15(B)(2)(a) GROUPING FACTOR - 0.8...NEC 310.15(B)(3)(a) CONDUCTOR AMPACITY = (INV O/P CURRENT ) x 1.25 / A.T.F / GX ...NEC 690.8(B) [(11 x 1.33) x 1.25] / [0.96 x 0.81 C � _ �� � = 23.81A O 1 SELECTED CONDUCTOR - #12 THHN ...NEC 310.15(B)(16) ' ,« 3 it It is a violation.of.the law for any person,unless (B) AFTER IQ COMBINER PANEL aetingunderthe di.reat.ion of a licensed TEMPERATURE DEBATE FACTOR — O 96 professional to alter an iterri 114t in anyway.if an yssleng Consulting, PLC item beafingthesealof a licensedprofessional 76 N,Moado whrook Drive„.Alpine U GROUPING FACTOR - 1 is altered,the altering.licensed professional shall New York CCA#0022571 affix to their item theirseal s nd the notation Signed 8/17/2025 "alteredby"foilowedby.their signature and the Expires?/31/2027 CONDUCTOR AMPACITY date ofSLrci,:aitefatian,and,aspecFfic description of the alteration. DRAWN BY SP = (TOTAL INV O/P CURRENT) x 1.25 / 0.96/ 1 ...NEC 690.8(B) DATE 8/14/2025 = [(44 x 1.33) x 1.25] / [0.96 x 11 = 76.20 A REVISION SELECTED CONDUCTOR - #4 THWN-2 ...NEC 310.15(B)(16) SIGNATURE PV-4.1 ELECTRICAL CALCULATIONS CONTRACTOR Solar Module Solar Module ELEMENT Microinverter COMBINER PANEL ENERGY Main Service d IN Panel SOLARI BATTERY BACK UP1631.779.79931 E2SYS.COM Outside Door 3A AC Disconnect Outside Door ELEMENT ENERGY LLC 3,9,10 7470 SOUND AVE, Inside Door Inside Door MATTITUCK, NY 11952, USA =bles should be marked by the manufacturer 5 6 7 6 3,6,8,9,1 1 6 5,67 +1 631 760 7262 ' LIC TYPE: HOME *Custom IMPROVEMENT, MASTER Directory ELECTRICIAN NEC 690.13(B) Placard LIC NO.: 67461-HI, 52689-ME NEC 690.13(B) NEC 705.12(A) NEC 690.54 NEC 690.56(B) NEC 705.12(B)(3) NEC 690.56(C) PROJECT INFO&ADDRESS NEC 705.10 NEC 705.12(B)(3) NEC 690.13(B) JESSICA FREDRICKS NEC 690.56(B) 1105 MILL LN, NEC 705.10 PECONIC, NEC 705.12(A) NY 11958, USA NEC 705.12(B)(3) ® CAUTION:SOLAR ELECTRIC SYSTEM SIZE SYSTEM CONNECTED DC SIZE: 18.700 KW DC-(STC) ELECTRIC SHOCK HAZARD AC SIZE: 14.080 KW AC IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED SOLAR PV SYSTEM EQUIPPED CAUTION- WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE 2] I ° F91 swITCHTOTHE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: "OFF'POSITION TO SO ARELECTRIC SHUTDOWN PV SYSTEM wPaNe�s ELECTRIC SHOCK HAZARD AND REDUCE SHOCK HAZARD MILL LN THE DC CONDUCTORS OF THIS IN THE ARRAY UTILITY DISCONNECT PHOTOVOLTAIC SYSTEM ARE UNGROUNDED (OUTSIDE GARAGE) AND MAY BE ENERGIZED COMBINER PANEL (OUTSIDE GARAGE) a`o f UM Co-D F3] I WARNIN 110 CAUTION: SOLAR CIRCUIT 0 ELECTRIC SHOCK HAZARD ( UTILITY METER OVERHEAD SERVICE) DO NOT TOUCH TERMINALS (POLE MOUNT) f, IE II i t TERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM AC DISCONNECT �-y LOAD SIDES MAY BE ENERGIZED RATE• OUTPUT CURRENT 58.52 . MAIN SERVICE PANEL U� .C'J,y �i? r IN THE OPEN POSITION 11 (INSIDE BASEMENT) It is a violation of the law for any person;unless acting under the direction of a licensed [4] WARNING-El_ctric Shock HazardprofessioralL,to alter an item in any ff.an Ul�yssling Cons9f11ting, PLLC No user serviceable parts inside item bee ring the seal.of a-licensed Professional 76 N. Meadowbrook Drive„Alpine U PV ARRAY is altered,the attering licensed professional sha lE New Yoirk COA#0022571 affix to their item theinseal and thenotation Signed 8/17/2025 "altered by"foilowed'trytheir signature and the Expires 7/31/2027 F-511 WARNING:DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM date o-such'alteration,and a specific description of the alteration. DRAWN BY SP [6] WARNING: PHOTOVOLTAIC DATE 8/14/2025 POWER SOURCEREVISION SIGNATURE • WARNINGCONNECTION D• NOT PV-5 RELOCATE • ' ' LABELS CONTRACTOR ® ELEMENT ENERGY SOLAR I BATTERY BACKUP 1631.779.79931E25YS.COM ENGINEERING DRAWINGS MECHANICAL CHARACTERISTICS ELEMENT ENERGY LLC Front Side Back 7470 SOUND AVE, � ,uc D,iu es9 ,calm^,azsa• No.of Half Cells 108(2 x 541 Dimensions 1722 x 1134 x 35mm 167.79 x 44.65 x 1.38 inch) MATTITUCK, NY 11952, USA Weight 22.Okg 148.516s) +1 631 760 7262 Front Glass 3.2mm,AnU-ReftedionCoating LIC TYPE: HOME High Transmission,Low Iron,Tempered Glass L Frame Anodized Aluminum Alloy . IMPROVEMENT, MASTER o ELECTRICIAN Junction Box IP68 Rated �7 - �-- LIC NO.: 67461-HI,52689-ME E v Output Cables 12 AWG,1400mm 155.12in)or Customized Length � . . . f ® �-.. i Connector Staubli MC4 Fire Type Type 1 PROJECT INFO&ADDRESS 17, --1 Pressure Rating 5400Pa!Snow)&2400PalWind) JESSICA FREDRICKS T i �� _ 1105 MILL LN, EAGLE8 54 G6R TEMPERATURE CHARACTERISTICS PECONIC, 420-440 WATT • N-TYPE TOPCON L ±2mm Temperature Coefficients of Pmax -0.29%/°C Y 11958, USA '-"- Width:±Zmm Temperature Coefficients of Voc -0.25°b/°C o � it Positive power tolerance of 0-+3°/D - � - xi Height: it �_ 9 Temperature Coefficients of lsc 0.045//°C SYSTEM SIZE '_3]_ _l Row Pitch-±2mm • � ,-< Nominal Operating Cell Temperature lNOCTI 45s.2°c DC SIZE: 18.700 KW DC-(STC) • NYSE-listed since 2010,Bloomberg Tier 1 manufacturer AC SIZE: 14.080 KW AC • Top performance in the strictest 311 party labs ELECTRICAL PERFORMANCE&TEMPERATURE DEPENDENCE MAXIMUM RATINGS • Automated manufacturing utilizing artificial intelligence Current-Voltage&Power-Voltage Temperature Dependence Operating Temperature(°C) -40°C--85°C • Vertically integrated,tight controls on quality Curves 1440W) of Isc.Voc.Pmax Maximum System Voltage 1000VDC • Premium solar factories in USA,Vietnam,and Malaysia ,<1- „° Maximum Series Fuse Rating 25A uD KEY FEATURES PACKAGING CONFIGURATION Superior Aesthetics z- __ _ i (Two pallets=One stack) G Black backsheet and black frame create ideal look for 31pcs/pallets,62pcs/stack,806pcs/40 HO Container 5 iD IS 20 23 30 ]5 <D residential applications. Voltage IV! 3D ogy N-Type etts with Ji N-type cells with Jinkds in-House TOPCon technology • �° � � � � '� WARRANTY offers better Performance and improved reliability. Celt Temperature(°C) • 25-year product and 30-year linear powerwarranty G Thick and Tough 1"year degradation not to exceed 1%•each subsequent year not to Fire Type 1rated modute engineered with a thick frame, exceed 0.4%,minimum power at year30 is 87.4%or greater. 3.2mm front side glass,and thick backsheet for added durability. Shade Tolerant ELECTRICAL CHARACTERISTICS Twin array design allows continued performance Module Type JKM420N-54HL4-B JKM425N-54HL4-B JK1,1430N-541,11-4-B JKM435N-54HL4-B JKM440N-54HL4-B even with shading by trees or debris. STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT Protected Against ALL Environments Maximum Power[Pmax) 420Wp 316Wp 425Wp 320Wp 43OWp 323Wp 435Wp 327Wp 44OWp 331Wp Certified to withstand humidity,heat,rain,marine environments, Maximum PowerVoltage(Vmpl 32.16V 29.95V 32.37V 30.19V 32.58V 30.30V 32.76V 30.50V 32.99V 30.73V Q wind,haitstorms,and packed Snow. Maximum Power Current(imp) 13.06A 10.55A 13.13A 10.60A 13.20A 10.66A 13.27A 10.72A 13.34A 10.77A , Warranty Open-circuit Voltage(Voc) 38.74V 36.80V 38.95V 37.00V 39.16V 37.20V 39.36V 37.39V 39.57V 37.59V 25-Year product and 30-year linear power warranty. Short-circuit Current(lsc) 13.51A 10.91A 13.58A 10.96A 13.65A 11.02A 13.72A 11.08A 13.80A 11.14A Module Efficiency STC f%) 21.51% 21.76% 22.02% 22.28% 22,53% *STC: :®=Irradiance 1000W/m2 !% Cell Temperature 25°C � AM=1.5 DRAWN BY SP. • 150900120150uatityStandards ISD450ot:201aoccupalional - NOCT:-4 Irradiance 800W/m' Ambient Temperature 200C � AM=1.5 Wind Speed 1m/s • 1S016001:2015Environmenta'Standards Health&Safety Standards rw �� UL US DATE 8/14/2025 • IEC61215,IEC61730 certified products UL61730 certified products 'Power measurement tolerance:±34'D LISTED REVISION SoEaa The Pomponyresen•es the final riy^htfor explanation or.anyo)the information presented hereby.lKMS00-420M-SGNL4-8-F7-US S�Z BUILDING YOUR TRUST IN SOLAR.WWW.JINKOSOLAR.US •finK0 BUILDING YOUR TRUST IN SOLAR.WWW.JINKOSOLAR.US _fin 0 SIGNATURE PV-6 RESOURCE DOCUMENT CONTRACTOR ® ELEMENT ENERGY 513LAR I BATTERY BACKUP 1631.779.791331 E25Y5.0 DM .ofENPHASE. IQ8MC Microinverter ELEMENT ENERGY LLC UNITS 108MC-72-M-US INPUT DATA(DC) 7470 SOUND AVE, Commonly used module pairings' W 2 0-460 MATTITUCK NY 11952 USA +1 631 760 7262 wModule compatibility To meet compatibility,PV modules must be within the following max.Input DC voltage and max.module 1_ LIC TYPE: HOME Module compatibility can be checked at httos://enphase.com/installers/microinverters/calculator. MPPTvoltagerange V 25-45 IMPROVEMENT, MASTER ELECTRICIAN Operating range V 18-58 LIC NO.: 67461-1-11, 52689-ME Min./Max.start voltage V 22/58 Max.input DC voltage V 60 PROJECT INFO&ADDRESS Max.continuous operating DC current A 14 JESSICA FREDRICKS Max.input DC short-circuit current A 25 Max.module l A 20 1105 MILL LN, Overvoltage class DC port 11 P ECON 1 C, DC port backfeed current mA 0 NY 11958, USA PV array configuration Ungrounded array;no additional DC side protection required;AC side protection requires max 20 A per branch circuit OUTPUT DATA(AC) UNITS 108MC-72-M-US @240 VAC ��1118MC-72-M-US @208 VAC SYSTEM SIZE Peak output power VA 330 315 DC SIZE: 18.700 KW DC—(STC) Max.continuous output power VA 320 310 AC SIZE: 14.080 KW AC Nominal grid voltage(L-L) v 240,split-phase(L-L),180' 208,single-phase(L-L),120" Q8 M C Microinverter Easy to install Min./Max.grid voltage' V 211-264 183-229 -orming',software- Lightweight and compact with plug- Max.continuous output current A 1.33 1.49 defined microinverters with split-phase power conversion capability to convert DC power to and-play connectors Nominal frequency Hz 60 AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary Power line communication(PLC) Extended frequency range Hz 47-68 application-specific integrated circuit(ASIC),which enables the microinverter to operate in between components grid-tied or off-grid modes.This chip is built in advanced 55-nm technology with high-speed AC short circuit fault current over three digital logic and has superfast response times to changing loads and grid events,alleviating Faster installation with simple two-wire cycles A,, 2.70 constraints on battery sizing for home energy systems. cabling a Max.units per 20 A(L-U branch circuit 12 10 High productivity and reliability Total harmonic distortion % <5 { _ { Produces power even when the grid is down' Overvoltage class AC port III More than one million cumulative hours AC port backfeed current - mA 18 _l( of testing Power factor setting 1.0 Part of the Enphase Energy System, IQ8 Series Microinverters redefine Class II double-insulated enclosure P 9Y Y Grid-tied power factor(adjustable) 0.85 leading...0.85lagging IQ8 Series Microinverters integrate with reliability standards with more than one Optimized for the latest high-powered the IQ Battery,IQ Gateway,and the million cumulative hours of power-on PV modules Peak efficiency % 97.4 97.2 Enphase App monitoring and analysis testing,enabling an industry-leading CEC weighted efficiency % 97.0 96.5 software. limited warranty of up to 25 years. Microgrid-forming Nighttime power consumption mW 33 25 Complies with the latest advanced grid MECHANICAL support DATA Ambient temperature range -40"C to 65"C(-40°F to 149"F) • Remote automatic updates for the CERTIFIED latest grid requirements. Relative humidity range 4%to 100%(condensing) Configurable to support a wide range DC connector type Staubli MC4 of grid profiles Dimensions(H•W•D);Weight 212 mm(8.3")•175 mm(6.9")•30.2 mm(1.2");1.1 kg(2.43lbs) Connect PV modules quickly and easily IQ8 Series Microinverters are UL Listed to the IQ8 Series Microinverters that have as PV rapid shutdown equipment and Meets CA Rule 21(UL 1741-SA)and IEEE Cooling Natural convection-no fans integrated MC4 connectors. conforms with various regulations when 1547.2018(UL 1741-SB) Approved for wet locations;Pollution degree Yes;PD3 installed according to the manufacturer's instructions. Enclosure Class II double-insulated,corrosion-resistant polymeric enclosure NOTE: 108 Microinverters cannot be mixed together with Environ.category;UV exposure rating NEMA Type 6;outdoor • Previous generations of Enphase microinverters COMPLIANCE DRAWN BY SP (107 Series,106 Series,etc.)in the same system *Meets UL 1741 only when installed with IQ System Controller 2 and 3. 10 Gateway is required to change the default grid CA Rule 21(UL 1741-SA),UL 62109-1,IEEE 1547:2018(UL 1741-SB),FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 profile at the time of installation to meet the local Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014,NEC 2017,NEC 2020,and NEC 2023 section 690.12 and DATE 8/14/2025 Authority Having Jurisdiction(AHJ)requirements. C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's instructions. Q 2023 Enphase Energy.All rights reserved.Enphase,the a and CC logos,IQ and certain other marks listed at (1)No enforced DC/AC ratio. REVISION httos•//enphase mm/trademark-usage-guidelines are trademarks of Enphase Energy,Inc.in the US and other countries. (2)Nominal voltage range can be extended beyond nominal if required by the utility. Data subject to change. IQBMC-MC4-DSH-00049-3.0-EN-US-2023-10-18 (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch In your area. 108MC-MC4-DSH-00049-3.0-EN-US-2023-10-18 SIGNATURE PV-6.1 RESOURCE DOCUMENT CONTRACTOR jj ELEMENT ENERGY 513LAR I BATTERY BACKUP 1631r779r79931 MY5.COM ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ':h ENIPHASE. IQ Combiner 5/5C MECHANICAL DATA ELECTRICIAN 3]S era a49S cmn16.8cm(14.]5'n19.5?6.639.Height is 21.06'(53.5 cal wdh mam6rg LIC NO.: 67461-HI,52689-ME Dimensions(WxHSO7 bmcte[s Weight 75 to(165Ibs) F IliConbiner5withwGatewaypintailciromboardfwhrtegratadrarenuegradePvproduction Ambient ship-anerange -,lCC[146'C(-40•Ft1IlS) PROJECT INFO&ADDRESS r 10 Combiner 5(X-Ili- metering-240-5) metering(ANSIC12.2(120.5'%).consumption monitoring(t 25%)and TO Battery-mining(12.5%1. In:Nudes a elver solar shield todoflem heal Cooling Natural convection.plus heat shield ENa-ASE JESSICA FREDRICKS 10 Comb ANSI-In 10tO-5 ),con ntedctr manic ard for Integrated 10 Battegrade PVpng(±2.ion Enclosure env'ucnmenlalrazing Outdoor,NRR-certitietl.NEMA type 3R,polyter5onato construction 10 Combiner 5C(X-10-AMI-240-5C) I-W.Meng(ANSI,Mobil Cohn consumption d..(ELLM.5%)aril lOBanoymonit Id..22.5%). sparhi ld1.daMobileComtectceCuiermodem(CELLMODEM-MI-O6-SP-05)r.lndudesasuver 20Ato ake,br nchinpn,14to4A'NGcopperconductors 1105 MILL LN, solar shield deflect heat 60A breakw bench input 41s 1/0 AVdG copper croMuctors Wire sues Main Wit combned a4putt0 to 2/O AWGcapper corducton pECONIC k)a HAVS IN THE BOX Neutral and ground.)4 to l/Ocopper ranductors pla gy-g....t to comprehensive.remote ma'mewnce and Alwitinfoilow bey coda requvoments far conducts,sang 7 f OGatewaypnnteCdeuitboard main g-htfe mirmf IQSy rem NY 11958, USA management of the Enphaze IQ System Buin-m CTRL board tw wired uxnmun'wtron with q Battery Sp and Ili System Controller 3/3G. I Communicetbn(ImPremise conrrectiviry) 4 z20A bmakars.staWrg 10 Series Integrated Power Li m e Cemumcipn at for tO Series Motu;-, j &,;flan 125A bulbar with support tort a 70 Gateway.later aril Nucoiarnift sand Ili Battery 5P AhAlide Up to 2.600 meta-(8,530 feet) 10 Gateway break,, Cu..lineake,2 pole.lO A/15A COMMUNICATION INTR A s clamp CT m SYSTEM SIZE X-I C-A ..p., Product..CT Prewhed revenue grade solid cons M.actb mte up 1o0.5% Ime,oded Wi-F7 SMTb/g/n(dual band 2.4 GHL5 Ghz).far connecting the Enpl-done vb the..... X-I0-AMI-240-5 DC SIZE: 18.700 M DC-(STC) MI-240-SC Consumptim CT Two consumption all s.hipped twit.the box.accurate up[o 25% WFF range(recommended) ilia I°Ba-,y CT Ora battery metering clamp CT.shipped with the bon.actuate up to 2.5% Bumpoth BLE42.Ili in range be mnfigw,Wi-FISSID AC SIZE: 14.080 MAC IQ Combiner 5/5C CTRL board Ca rim+basic for wired communication with lO System C thafr 3/3G and the lO Battery So Ethernet Coma,SOL3,Cat5E(w Cat 6)UTP Ethemm ceble(hot imiuded).for cpractng to the a Enphase Mobile Cs.-mect(only with 10 Combiner 5C) 4G-based LTE-MI ceEWar modem(CELLMODEM-MH06-SP-OS)with a Syear T-Mobile data plan Etmhas Clpudvla-Ii im.m.t The IQ Combiner 5/5C consolidates interconnection equipment into a single enclosure and Smartss Acceories M ward hds t Spare ea -for CTRL board Mobile Conned CELLMODEM-MI-06-SP-05o,CELLMODEM-MI-O6-AT-OS Ild.dod W..l°Comb-,5C) streamlines TO Series Microinverters and lO Gateway installation by providmg a consistent- Includes IQ Gateway for DigitaU/O Digital inputlionout for grid operator control pre-wired solution for residential applications.Ili Combiner 5/5C rues wired control communication and control ACCESSORIES AND REPLACEMENT PARTS[NOT INCLUDEDj ORDER SEPARATELY) communication and is compatible with IQ System Controller 3/3G and IQ Battery 5P. Includes Enpluse USB2 0 Fw Moble cormett • MabBe Conned CFLLMOOEN-MFOG-SP-05 4G-based LTE-Ml ca9ula+modem wl;t-a5-tea,T-Mob2e dare plan (CELLMODEM-MI-06-SP-05),only CELLMODEM-MI-O6-AT-05 4G-based LTE-Ml cellular modem with,5-year AT&T data plan Access Point TAP)mode For connection between the lG Gateway and a mobile device running the Enphan lmalb,,Ape The lQ Combiner 5/5C.along with lO Series M oremierters,Ili System Controller 3/3G.and with Ili Combiner 5C Metering ports UDto two Conwmpfon cis,one l0,anent'CT.and one Production CT 10 Battery SIP provides you with a complete grid-agnostic Enphase Energy System. Supports Eaton BR2t0.BR215.BP220.BP230.BR240,BR250.and BR260 ctcu4 breakers •Supports fleodble networking:WrFi, Circui:bmatan(ofl-the-sne!6 Supporn Enron BR2208.BR2306.and BR2408circuit[broaLars compat3le withhold-down kit Ethernet,dr cellular Power Iva cotmnunlra[mn 90-TO kit Provides production meterifg CucuA breakors(po+ided by Enphase) BRK-10A-2-240V,BRK-ISA-2-240V.BRK-20A-2P-240V.BRK-15A-2P-24OV-B.,,d BRK-20A-2P- (revenue grade)and consumption 240V-B(More de[aRsn Accescries'sxrton) Web Apt Refer to Mtps.'//dovdoow-v4.e4.pnaa om nroNtoring XA-SOLARSHIELO-ES Replacemm4 solar shields 10 Combiner 5/5C Local API Rafw to guide for localit L API XA-E8V2-pCSA-5 Ili Gateway neplo ba-printed circuit board(PCB)far Combiner 5y5C Fast'to install 10 Series Mierdnverters 10 System Controller 3/3G Mounts to one stud with centered %-I0-NA-HO-125A Hold-down kit compatibb with Eaton SR-B series drwit br.aIas(with xmws) 10 Combiner UL 1741.0 N/CSA C222 No.101%Title 47 C FR.Part 15.Class B.ICES 003 The high-powered smart grid-ready lO Series Provides microgrid imopeonnaction brackets ELECTRICAL SPECIFICATIONS UL 60601-1/CANC54222 No.61010-/.IEEE 1547:2018(UL 1741-58.3'"Ed.) Microinverters(106.107.and I08 Series) device(MID)functionalityb Ili GaulIEEE 2030.5/CSIP Cam' dramaticall fif the installation y Supports bottom.back.and side Rating eon pSI C1 ylimp y process automaticallytletect)nggridfailuresand conduit entry ProducUonmetering:aNslCnpr-axuracy clan(15(Pvproduclim) seamlessly transitioning the home energy System voltage 120/240 VAC.60 Hz system from grid power to backup power Supports up to four 2-pole branch COMPATIBILITY circuits for 240 VAC plugia breakers Busbarmting T25a l0 System Cortudler 3/3G SC200DInC240US01.SC200GInC240U501 (notincluded) Fauhcuma ing 10 WC Ili Battery 5P IOBATTERY-5P-IP-NA 80 A total Pit branch circuits comvwav tune A4cro'uwertw 105.107.and108 Series Mkrohw-ni I Maximum mratirg(input from PV/stom9e) 64A •Bluetooth based W Fi provislonirg Ic( for easy Wi-F setup Branch circuits(sdarana/or storage) Up to four 2-pole Eaton SR aeries dimrbw,d go..orb CG)t..k,monly(nwioduded) &r Maimum total branch ce-it tv-k,r m' (,) tag(input) BO Apt distributed general n/95A with lOGarewaybreater)nduded Reliable 10 Gateway breaker 10 A or 15 Ara ag;GE/Si...m/Eaton included •Durable NRTL-certified NEMA type 3R enclosure produc5onmetermg CT 200 A slid toe pre-inrtnPed antl wired to I°Gateway Ili Battery SP If]Load Controller Fullyintegrated AC battery system.Includes six Helps prioritize essential appliances 5-year limited warranty Consumption monitoring CT(CT-200-CLAMP) A pair of200A clamp-style cumenttremflint-is included with the bon field-replaceable IOSD-BAT Microinverters during a grid outage to optimize Two years laborreimb-al Ili Ban.,me,vig CT 200a Gampaty)enarent[mmformer foriO Banerymeteatg.included vrith:ne bon energy consumption and prolong program coverage included for both battery life the 10 Combiner SKUs •UL1741 listed ® LISTED 5-year 'aPk.9-and-wvmev:xtu!rerada«e made.-,x.'rt�aawmsom«,.wtar=(Arub'a.da us.caaxaMaRo.Pnwtoaa.and ma limited warranty usrr9,n lssw;.wiwa marahm,g:::r.eatwa. na inrxvaumr:r-.) 412123 E.phaso Energy.All dgms reserved.Enphna.dm a and CClogos,10.and tartan attar marks Irsmd a[ h1�r//endorse com/trademahvsaoesuid_are trademarks of_P_Energy,Ix.nthe US.-w-herru rim s. Datasubi-t0charge. ce-s-SC DSH-0ODo).LpEN-Ua-Tan-0a-Z1 IUC-}SC-n54-DDaDl-2D-EN-US-3a33i]A-T] IOG-S-SC-DSN-(M100]-To-EN-UST023-09-TT DRAWN BY SP DATE 8/14/2025 REVISION SIGNATURE PV-6.2 RESOURCE DOCUMENT CONTRACTOR ® ELEMENT ENERGY .0L I RO N R I DG E Al Aire Rail SOLARI BATTERY BACKUP1631.779.79931 E25Y5.COM ELEMENT ENERGY LLC 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME SEE DESCRIPTION IMPROVEMENT, MASTER ELECTRICIAN LIC NO.: 67461-HI, 52689-ME PROJECT INFO&ADDRESS JESSICA FREDRICKS 1105 MILL LN, PECONIC, ITEM NO DESCRIPTION QTY IN KIT NY 11958, USA 1 AIRE RAIL, Al, BLACK(OR CLEAR), 170" 1 SYSTEM SIZE DC SIZE: 18.700 KW DC-(STC) AC SIZE: 14.080 KW AC PART NUMBER DESCRIPTION AE-Al-170B AIRE RAIL, Al, BLACK, 170" AE-Al-170M AIRE RAIL, A], MILL, 170" 1) AIRE Al RAIL SECTION PROPERTIES 1.40 PROPERTY VALUE �1.17� TOTAL CROSS-SECTION AREA 0.364 in' SECTION MODULUS (X-AXIS) 0.146 in MOMENT OF INERTIA (X-AXIS) 0.126 in 1.38 1.04 1.70 MOMENT OF INERTIA (Y-AXIS) 0.114 in e TORSIONAL CONSTANT 0.001 in4 0.22 POLAR MOMENT OF INERTIA 0.239 in4 PART NUMBER MATERIAL FINISH DRAWN BY SID AE-Al-170B 6000 SERIES ALUMINUM BLACK DATE 8/14/2025 AE-Al-170M 6000 SERIES ALUMINUM CLEAR REVISION V1.10 SIGNATURE PV-6.3 RESOURCE DOCUMENT CONTRACTOR ll ELEMENT ENERGY 50LAR1BATTERY BACKUP 1631.779.79931E25YB.COM AMIL IRON RIDGE End Fastening Object A�.� IRONRIDGE Universal Fastening Object® ELEMENT ENERGY LLC Onlyfor installation and use with dge products in accord with written instructions seea Iro MATTITUCKe NY 11952� USA 7470 SOUND AVE, IronRidge.com/UF0 +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN e LIC NO.: 67461-HI, 52689-ME 1 PROJECT INFO&ADDRESS JESSICA FREDRICKS 1105 MILL LN, UNIVERSAL FASTENING OBJECT' PECONIC, NY 11958, USA PART NO. DESCRIPTION UFO-END-01-Al END FASTENING OBJECT(END CLAMP,30-40mm),MILL SYSTEM SIZE DC SIZE: 18.700 KW DC-(STC) UFO-END-01-Bl END FASTENING OBJECT(END CLAMP,30-40mm), BLACK AC SIZE: 14.080 KW AC 1 .43 1.0� ITEM NO. DESCRIPTION UFO-CL-01-Al UNIVERSAL MODULE CLAMP, CLEAR U . - L- 1-B .39 �+-- I 1.27 COMPATIBLE WITH .58 30-40mm MODULE FRAMES 2 ,29 �7/16"Head I —►� .61 �.25 COMPATIBLE WITH 0.37 UC 30-46mm MODULE FRAMES 1.0 01.12 7/16"HEAD .97 O .25 Property Value ITEM NO. MATERIAL FINISH Material 300 Series Stainless Steel 1 6000 SERIES ALUMINUM MILL OR BLACK Finish Clear and Black 2 300 SERIES STAINLESS STEEL CLEAR AND BLACK DRAWN BY SP V1.0 v1.32 DATE 8/14/2025 REVISION SIGNATURE PV-6.4 RESOURCE DOCUMENT CONTRACTOR ELEMENT d El ® ENERGY w ^= SOLARI BATTERY BACKUP 1631.779.7993IE25Y5.COM ZA99L IRONRIDGE Bonding Hardware Z.2 IRONRIDGE Grounding Lug ELEMENT Y LLC 0 SOUND AVE MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER 3 3 1 ELECTRICIAN 2 LIC NO.: 67461-HI, 52689-ME 1 3 ® ® 2 PROJECT INFO&ADDRESS JESSICA FREDRICKS ITEM NO. DESCRIPTION 1105 MILL LN, 1 BOLT,T CSTM,3/8-16 4 PECONIC, 2 BOLT,BONDING 3/8-16 SQ HEAD ITEM NO. DESCRIPTION NY 11958, USA 3 NUT, BONDING STEP 1 LUG,GROUNDING;LAY-IN-LOW PROFILE 2 BOLT, 1/4-28 X.750"HEX CS SST SYSTEM SIZE BONDING HARDWARE 3 NUT, FLANGE HEX 1/4-20 SST DC SIZE: 18.700 KW DC-(STC) 4 BOLT,T CSTM 1/4-20 X 1.188"LOCK SS AC SIZE: 14.080 KW AC Part Number Description BHW-TB-02-Al T-BOLT,BONDING HARDWARE Part Number Description Wire Size Range(AWG) BHW-SQ-02-Al SQUARE-BOLT,BONDING HARDWARE XR-LUG-03-Al GROUNDING LUG,LOW PROFILE 4-10 1) BOLT, T CSTM, 3/8-16 2) BOLT, BONDING 3/8-16 SQ HEAD ])Lug, Grounding 3) Nut, Flange Hex 1/4-20 .82 � .63 1.00 1.00 t 3/8-16 THD 4 .63 71 1/4-20 THD .59 CIM 38 56 n .29 24 0.26 7/16"Head��'� 24 3/8-16 THD7 �-1.75--►i Property Value Property Value Property Value Material 300 Series Stainless Steel Material 300 Series Stainless Steel Material 300 Series Stainless Steel Property Value Finish Clear Finish Clear Finish Clear Material Tin Plated Copper Finish Clear Matte 4) Bolt,T CSTM 1/4-20 x.750 3) NUT, BONDING STEP --L .24--� � 1/4-20THD 3/8-16 THD 2) Bolt, 1/4-28 x.750 IHex .75 7/16" y �—.16 .61 )Z) ( `( Head 1/4-28 THD 75 �— "`JJJ 26 75 �- 7/16"Head .79 Property Value Property Value Property Value Material 300 Series Stainless Steel Material 300 Series Stainless Steel Material 300 Series Stainless Steel Finish Clear Finish Clear DRAWN BY SIP Finish Clear v1.30 V1.10 DATE 8/14/2025 REVISION SIGNATURE PV-6.5 RESOURCE DOCUMENT CONTRACTOR ELEMENT E] M ENERGY SOLARIBATTERY BACKUP 1631,779.79931E25YB.COM A4 IRONRIDGE UFO' Family of Components System Diagram ELEMENT ENERGY LLC 7470 SOUND AVE, - . MATTITUCK, NY 11952, USA +1 631 760 7262 Simplified Grounding for Every Application - - - - - - - -- - - - - - - - - - - - - - - - - - - - LIC TYPE- HOME IMPROVEMENT, MASTER The UFO°family of components eliminates the need for ELECTRICIAN separate grounding hardware by bonding solar modules ---- direct) to IronRid e°XR Rails°.All system LIC NO.: 67461-HI, 52689-ME y g y types that feature the UFO°family—Flush Mount°,Tilt Mount°and - Ground Mount°—are fully listed to the UL 2703 standard. PROJECT INFO&ADDRESS UFO°hardware forms secure electrical bonds with both the - - - - - - - - - - - - - - - - - - -�- - - - - - - - - - - - - - - - - - - JESSICA FREDRICKS module and the rail, resulting in many parallel grounding 1105 MILL LN, paths throughout the system.This leads to safer and more _. ._ _ _ . PECONIC, reliable installations. _ NY 11958, USA Only for installation and use with IronRidge products in accord with °` — — — — — — — — — — — — — — — written instructions.See IronRidge.com/UFO _ SYSTEM SIZE DC SIZE: 18.700 KW DC-(STC) � Universal Fastening Object(UFO ) AC SIZE: 14.080 KW AC Stopper Sleeve The UF08 securely bonds solar modules to XR The Stopper Sleeve snaps Rails®.It comes assembled and lubricated,and _ _ _ _ _ _'_ _ _ _ _ _"_ _ _ _ _ _ _ _ _ _ _ ' _ _ _ _ _ _ onto the UFO ,converting it can fit a wide range of module heights. — — _ — — _ — — — — — — — — —'— — — �— — — — — — — — — — — — — — — i — — — into a bonded end clamp. O UFO Stopper Sleeve • Grounding Lug m BOSS" Splice = Ground Wire 'fit► � $+'`'�� ��`' _ `` .,\ - wy �rVI 9 Approved,Enphase microinverters can provide equipment grounding of IronRidge systems,eliminating the need for grounding lugs and field installed equipment ground conductors(EGC).A minimum of two microinverters mounted to the same rail and connected to the same Engage cable is required.Refer to installation manuals for additional details. UL Certification Cr ! • ! ! The IronRidges Flush Mount®, ! • ' F �. , . ;4 .j ��� Tilt Mount, and Ground Mount XR Rails .i d XR100&XR1000 i - BOSS°Splice � � - Systems have been listed to UL - Bonded Structural Splice f' , 2703 by Intertek Group plc. UFO®/Stopper d d d connects rails with built-in - bonding teeth.No tools or BOSS®Splice d d NIA hardware needed. SOi1 , UL 2703 is the standard for j, evaluating solar mounting Grounding Lugs 1 per Row 1 per Row 1 per Array systems. It ensures these devices Microinverters will maintain strong electrical and &Power Compatible with most MLPE manufacturers. Grounding Lug mechanical connections over Refer to system installation manual. Asingle Grounding Lug Bonded Attachments Optimizers an extended period of time in connects an entire row The bonding bolt attaches p of PV modules to the and bonds the L-foot@ to the extreme outdoor environments. Fire Rating Class A Class A N/A DRAWN BY SP -�— grounding conductor. rail.It is installed with the Tested or Evaluated with over 400 Framed Modules DATE 8/14/2025 same socket as the rest of the Modules system. Q Go to Iron Ridge.com/UFO Refer to installation manuals for a detailed list. REVISION SIGNATURE PV-6.6 RESOURCE DOCUMENT CONTRACTOR ri ELEMENT ® ENERGY BOLARIBATTERY BACKUP1631.779.79931E25YS.COM ELEMENT ENERGY LLC ®ak IRONRIDGE QuickMount® Halo UltraGrip 1. Halo UltraGrip 38 7470 SOUND AVE, MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN LIC NO.: 67461-HI, 52689-ME PROJECT INFO&ADDRESS RD STRUCTURAL SCREW PN RD-1430-01-M1 3.35 JESSICA FREDRICKS SOLD SEPARATELY SHOWN FOR REFERENCE 1105 MILL LN, PECONIC, NY 11958, USA SYSTEM SIZE Release Liner shown for reference DC SIZE: 18.700 KW DC-(STC) AC SIZE: 14.080 KW AC 3.83 0 0 0 J 0.26 0 0 1.63 1.56 I ITEM NO DESCRIPTION QTY IN KIT 1 QM Halo UltraGrip(Mill or Black) 1 O O .34 1"1 it PART NUMBER DESCRIPTION QM-HUG-01-M1 Halo UltraGrip-Mill QM-HUG-01-B1 Halo UltraGrip-Black 3.00 Property Value Material 300 Series Aluminium Finish Mill or Black DRAWN BY SP DATE 8/14/2025 02022 IronRidge.Inc.All rights reserved.Visit v—Jr-patents.com for patent information. QM-HUG-01-B1 or QM-HUG-01-Ml Cut Sheet Rev 1.0 ©20221ronRidge.Inc.All rights reserved.Visit w .ir-patents.com for patent information. QM-HUG-01-Bl or QM-HUG-01-Ml Cut Sheet Rev 1.0 REVISION SIGNATURE PV-6.7 RESOURCE DOCUMENT CONTRACTOR AMIL IRONRIDGE QuickMount° RD Structural Screw ELEMENT IM U ® ENERGY BOLARIBATTERY BACKUP1631.779.79931E25YB.COM ELEMENT ENERGY LLC 7470 SOUND AVE, 1 2 MATTITUCK, NY 11952, USA +1 631 760 7262 LIC TYPE: HOME IMPROVEMENT, MASTER ELECTRICIAN LIC NO.: 67461-HI, 52689-ME PROJECT INFO&ADDRESS JESSICA FREDRICKS 1105 MILL LN, PECONIC, NY 11958, USA ITEM NO DESCRIPTION QTY IN KIT 1 Self Drilling Screw, #14,Wood Tip 1 SYSTEM SIZE 2 Washer, EPDM Backed 1 DC SIZE: 18.700 KW DC-(STC) AC SIZE: 14.080 KW AC PART NUMBER DESCRIPTION HW-RD1430-01-M1 RD Structural Screw 1. Self Drilling Screw,#14,Wood Tip .22 #14 DIA 5/16" Head 0.43 3.00 Property Value Material 300 Series Stainless Steel Finish Clear 2. Washer, EPDM Backed .13 �-- 06.26 0.57 DRAWN BY SP DATE 8/14/2025 Property Value REVISION Material 300 Series Stainless Steel Finish Clear SIGNATURE ©2022 IronRidge,Inc.All rights reserved.Visit www.ir-patents.com for patent information. QM-HW-RD-1430-01-M1 Cut Sheet Rev 1.2 PV-6.8 RESOURCE DOCUMENT