Loading...
HomeMy WebLinkAbout52235-Z �O"t.Of SO(/ryO� Town of Southold * * P.O. Box 1179 woe 53095 Main Rd Ulm.� Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 46739 Date: 12/17/2025 THIS CERTIFIES that the building SINGLE FAMILY DWELLING-ALTERATION Location of Property: 1585 Wood Way Cutchogue, NY 11935 Sec/Block/Lot: 109.-5-14.27 Conforms substantially to the Application for Building Permit heretofore,filed in this office dated: 06/26/2025 Pursuant to which Building Permit No. 52235 and dated: 09/05/2025 Was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Alterations to include a partially finished basement to an existing single-family dwelling as applied for. The certificate is issued to: Marco Prono , Danielle Powers Of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL: ELECTRICAL CERTIFICATE: 25-984 12/01/2025 PLUMBERS CERTIFICATION: tui o ' ed Signature 4�QPSO& TOWN OF SOUTHOLD BUILDING DEPARTMENT • TOWN CLERK'S OFFICE `*�o�s,�N��{ SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52235 Date: 09/05/2025 Permission is hereby granted to: Marco Prono 419 E 57th St Apt 13F New York, NY 10022 To: Construct alterations to an existing single-family dwelling for a partial finished basement as applied for.Amended 9/29/25 to relocate basement egress. Premises Located at: 1585 Wood Way, Cutchogue, NY 11935 SCTM# 109.-5-14.27 Pursuant to application dated 06/26/2025 and approved by the Building Inspector. To expire on 09/05/2027. Contractors: Required Inspections: Fees: Single Family Dwelling- Alteration $666.00 CO Single Family Dwelling-Addition /Alteration $100.00 Amendment Fee $0 Total $766.00 jdo Building Inspector ho�%of sourgo(c TOWN OF SOUTHOLD BUILDING DEPARTMENT • TOWN CLERK'S OFFICE ��r�ourrtr.N�' SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 52235 Date: 09/05/2025 Permission is hereby granted to: Marco Prono 419 E 57th St Apt 13F New York, NY 10022 To: Construct alterations to an existing single-family dwelling for a partial finished basement as applied for. Premises Located at: 1585 Wood Way, Cutchogue, NY 11935 SCTM# 109.-5-14.27 Pursuant to application dated 06/26/2025 and approved by the Building Inspector. To expire on 09/05/2027. Contractors: Required Inspections: Fees: Single Family Dwelling- Alteration $666.00 CO Single Family Dwelling-Addition /Alteration $100.00 Total $766.00 Building Inspector East End Inspection Agency, LLC rj�-�'_311 5 P.O. Box 35 East Quogue, New York, 11942 EE (631) 594-2272 Fax (631) 594-2598 office@eastendinspectionagency.com East End Inspection Agency CERTIFICATE OF ELECTRICAL COMPLIANCE This Certificate of Compliance is limited to the inspection and compliance of electrical equipment and/or work described below, installed by the applicant and not after the final inspection date listed. Owner: Danielle Powers Date: December 1, 2025 Address: PO Box 1698 Certificate No: 25-984 Mattituck, NY 11952 Location of Property Inspected 1585 Wood Way Cutchogue, New York STCM Dist 1000 Section: 109 Block: 5 Lot: 14.27 Permit Number [X] Renovation [X] Residential [X] Basement , ', ?i I Fixture Outlets- 11 t er Outlets- 14 DEC - 5 2025 Smoke Det- 1 3'ns,:9-,m ,•,•�� AC Units- 1 mini-split AC/Heat Pump = 1-6-80 GFCI Breakers- 1 CO Det- 1 Other Fixtures- 11 led ACFI Breakers-4 Date of Roughing Inspection: 10/23/2025 Date of Final Inspection: 11/26/2025 The electrical work and/or equipment described above were inspected and appear to be in compliance with local, state and national electrical code requirements at the time of inspection. Installer: Custom Lighting of Suffolk License Number: ME38893 PO Box 1698 Mattituck, NY 11952 Electrical Inspector: Edward Seltenreich OF SOUTyOIo # # TOWN OF SOUTHOLD BUILDING DEPT. cou�m.� 631-765-1802 INSPECTION [ ] FOUNDATION 1ST/ REBAR [ ] RO H PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ .] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION- [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]. RENTAL REMARKS: n, cite, klA_ DATE INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS 77-- r FOUNDATION (1ST) ------------------------------------ C FOUNDATION (2ND) z WWI �l c U O ►� P ROUGH FRAMING& (� PLUMBING 1 a C'^ — a r t� INSULATION PER N.Y. STATE ENERGY CODE rl FINAL ADDITIONAL COMMENTS +2�-a5 - +�'lerr —�D Y�,1� a �� o 0 NJ - � z -- d 4o5UfFat rho., TOWN OF SOUTHOLD—BUILDING DEPARTMENT G y z,, Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 y • a,�.:r� Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny_gov Date Received APPLICATION FOR BUILDING PERMIT ® EC EHE a `� For Office Use Only PERMIT NO. 5�V �J �CJ Building Inspector: UUN 2 6 2025 Applications and forms must be filled out in their entirety. Incomplete' Building Department applications will not be accepted. Where the Applicant is not the owner,an Town of Southold Owner's Authorization form(Page 2)shall be completed. Date:06.17.25 OWNER(S)OF PROPERTY: Name:Marco Prono and Danielle Powers SCTM#1000-109-05-14.27 Project Address: 1585 Woods Way Cutchogue, NY 11935 Phone#:212 542 0473 1Email:danielleandmarcoprono@gmail.com Mailing Address:419 East 57th St, Apt 13F New York, NY 10022 CONTACT PERSON: Name:Mark Schwartz Mailing Address:PO Box 933 Cutchogue NY 11935 Phone#:631 7344185 Email:mksarchitect@optonline.net DESIGN PROFESSIONAL INFORMATION: Name:same as above Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name:Chris Leaden Mailing Address:935 Fairway Drive Cutchoue, NY 11935 Phone#:631 8312526 1 Emaii:cleaden@gmail.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition @Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $79,500 Will the lot be re-graded? ❑Yes @No Will excess fill be removed from premises? ®Yes ❑No 1 PROPERTY INFORMATION Existing use of property: ) Intended use of property:FR?ggl Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R 40 this property? ❑Yes,KNo IF YES, PROVIDE A COPY. . Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water Issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone. Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors on premises and in building(s)for necessary inspections.False statements made herein are . Punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):Mark Schwartz ®Authorized Agent ❑Owner Signature of Applicant: % 17.25 CONNIE D.13U Ul I Notary Public,State of New York STATE OF NEW YORK) No.01BU6185050 S: Qualified in Suffolk County S ) Commission Explres April 14,2 2 COUNTY OF Suffolk Mark Schwartz L a j" �,-C` �" � / �� being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Architect/Agent (Contractor,Agent,Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this Oct y of � - 20 Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, 111D residing at 40 EaWff7ftffit112F fq� walk,MY 10M M cffiMW6Hft do hereby authorize to apply on my beh If to the Town of Southold Building Department for approval as described herein. (OAMM Owner' Signature Date UglutDR1111=1 Print Owner's Name 2 1/2" GYPSUM TO BE INSTALLED AT CEILING OF BASEMENT. TAPE AND SPACKLE, 3 COATS, SAND, PRIME AND PAINT, 1/2" GYPSUM TO BE INSTALLED INTERIOR FINISHED TRIM OVER 2X4 STUD WALL, AT 16"OC AS SELECTED BY OWNER R20 INSULATION AS PER RES-CHECK TAPE AND SPACKLE, 3 COATS, SAND, PRIME AND PAINT, LAMINATE FLOORING TO BE INSTALLED OR AS SELECTED BY OWNER. INSTALL PER WRITTEN INSTRUCTIONS (TYP) 1 INTERIOR DETAIL SCALE: 1/2" = V-0" P,\Ood REVISIONS: COMPLY WITH ALL CODES OF NEW YORK STATE&TOWN CODES APPROVED AS NOTED A REQ (RED AND CONDITIONS OF SOUTHOLDTOV," BA DA :�" 5 B.P. -._.......SOUTHOLDTOtMN PLANTING BOARD FE 7".Od BY:� SOUTHOLD T01%TRUSM NOTIFY BUILDING DEPARTMENT AT EXISTING BASEMENT WINDOW TO BE REMOVED N.Y.S.DEC 631-765-1802 8AM t0 4PM FOR THE ENLARGE OPENING FOR NEW EGRESS OPENING. SOUTHOLD HPC FOLLOWING INSPECTIONS: FRAME 2X8 ACQ ON INSIDE,SEAL OFF AS REQUIRED. INSTALL NEW EGRESS WELL WITH COVER TO CODE SCHD FOUNDATION-TWO REQUIRED /GR R FOR POURED CONCRETE (f S ; X- Con4ruc-I- 6+a,irs ct5 pcir 2020 ROUGH-FRAMING&PLUMBING Rai dln-I-f Q I Ccck o-F 1415 sec.. R 31 1 INSULATION 25'-9" FINAL-CONSTRUCTION MUST ELECTRIC W D BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS N Z ELECTRICAL O HORIZONTAL PROJECTION(k DEC K) INSPECTION REQUIRED UNFINISHED STORAGE — -- O INSTALL 5/8"TYPE-X FIRE RATED SHEETROCK O Z ON WALLS AND CEILLING AT FURNACE AREA O E 2 T^ 4"m 171 I - ICL Pd m r' Z N EGRESS WINDOW N p (PER CODE) ----- VERIFY SIZE PER 12'-0" --- WINDOW SIZE NIF)IF) p INSTALL SOLID-CORE DOOR __._____ RECREATION ROOM WITH WEATHERSTRIPPING 7-10 CEILING AND DOOR SWEEP "' ---'- SMOKE AND CO DETECTOR WELLCRAFT EGRESS DETAIL ["'I TO BE INSTALLED TO CODE ANTS '•' • 1.INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. �• ��f 1' to ---'--- - 2.WELL SIZE TO BE MINIMUM TX3'CLEARANCE.VERIFY AND .' ADJUST PER WINDOW SIZE USED. �. N 3.ESCAPE WELL TO HAVE COVER AS REQUIRED BY CODE INSTALL NEW STAIR WITH • a' NECESSAY RAILING(TYP) I . o Q o o I O I I ------------ FUEL OIL TANK �- 1AI/I. 37-9"L - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - a I V F- wl N� PROPOSED BASEMENT PLAN SCALE: 1/4" = V-O" Generated by REScheck-Web Software Compliance Cer�ificat� Project POWERS x Qo Z �Energy Code: 2018 IECC o Location: Southold, New York rw o Construction Type: 00 Single-family Project Type: Alteration U Project SubType: None O Climate Zone: 4 (5572 HDD) a Permit Date: Permit Number: All Electric false 2" Is Renewable false 2" Has Charger false false OO (9) (Q Qz" O O O O ® ® ® ® ® 2 Has Battery: 2" p false ® ® ® ® Has Heat Pump: CD N v ro 1 O Construction Site: Owner/Agent: Designer/Contractor: 011E O® BO OO OO ® ® ®® ® ® 1585 WOODWAY o LO 7� .2 FASTENER TYPE: SPACING: CUTCHOGUE, NY u `~ X O No.8 WOOD-SCREW Q }I w a � BASED ANCHOR WITH 16"OC +� 2in.EMBEDMENT LENGTH 11,I I JIL e �. Y,- 7 ! .I►(' •!i I 'R ' � dl 4`d :.way' I.4 I� ' ' Jr .�.i..'1,ai�.1W P 'jAg::,��,444,,4 O CU M .2 ® � 9 ® 9 cc ® ® WOOD-SCREWSNo.10 BASED ANCHOR WITH 16'OC O® m 2in.EMBEDMENT LENGTH ..r .fir .F+ US 1/4in.dia.LAGSCREW U c r1 BASED ANCHOR EMBEDMENT 16.00 Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each :slab-on- rade tin.EMBEDMENT LENGTH 9 9 C 9 ® ® g g p p p g - M assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. N a� i~ vv 3/4"APA PLYWOOD .) W v SHEATHING 1/2-APA RATED SHEATHING Envelope Assemblies GRADE PLYWOOD N (ALTERNATIVIVE:7/16'O.S.B.) 9 ® 99 ® 9 \ r Q Q 1/2"APA RATED SHEATHING _ O O ''�AI ,♦ '"" ` '. '` 4 ;. F bo Wall: Wood Frame, 16"o.c. 1.003 WLL 20.0 _ 0.0 0.059 0.060 __.... - W GRADE PLYWOOD ® � 58 59 (ALTERNATIVIVE:7/16"0.5.8.) ® ® cc ce ® Cc HOPPERS:Wood Frame ,.., Oo OQ 7 0.240 0.320 2 2 FASTENER TYPE: SPACING: SHGC: 0.18 U zxaDF#z EGRESS WINDOW: Wood Frame O No.8 WOOD-SCREW ADS SHGC: 0.32 12 0.290 0.320i 3 4 BASED ANCHOR WITH 10"OC WINDOW SILL 21n.EMBEDMENT LENGTH Compliance Statement. The proposed building design described here is consistent with the building plans, specifications,and other ® Z. ®® e ® P � p P 9 9 TYPICAL WINDOW IOPENING No.10 ANCHOR WITH calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in BASED ANCHOR WITH 1z"oc PANEL SPAN EQUAL ORt SMALLER 2in REScheck Version REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. H .EMBEDMENT LENGTH THAN 4 FEET' 1/4in.dia.LAGSCREW BASED ANCHOR WITH 16"OC Q 0 �'W d tin.EMBEDMENT LENGTH ® ® ® ® ® Name-Title Signature Date ® � , TYPICAL DOOR OPENING PANEL SPAN GREATER THAN 4 FEET MULTIPLE PLYWOOD ASSEMBLIES FASTENER TYPE: SPACING: S CONNECTED AND EQUAL OR SMALLER TOGZETHEDR#WITHUSTAINLLESSSTEEL U No.8 WOOD-SCREW OR GALVINIZED BOLTS W/WASHERS BASED ANCHOR WITH 8"Oc �y THAN 6 FEET AND NUTS @ 2'-0"O.C. 2in.EMBEDMENT LENGTH TYPICAL MULTIPLE OPENINGS No.10ANCHORWITH EASED ANCHOR WITH 9'OC 2in.EMBEDMENT LENGTH PANEL SPAN GREATER THAN 6 FEET 1/4in.dia.LAGSCREW Project Title: POWERS Report date: 06/17/25 AND EQUAL OR SMALLER BASED ANCHOR WITH 16"OC Data filename: Pagel of 1 ' THAN 8 FEET 2in.EMBEDMENT LENGTH WIND-BORNE DEBRIS PROTECTION FOR WOOD STRUCTURAL PANEL AS PER SEC. R301.2.1.2 NYS CODE: PROTECTION OF OPENING WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS WOOD STRUCTURAL PANELS WITH A MINIMUM THICKNESS OF 7/16" AND MIAXIMUM PANEL SPAN OF 8 FEET SHALL BE PERMITTED FOR OPENING PROTECTION IN ONE-AND TWO-STORY BUILDINGS. PANELS SHALL BE PRECUT TO ro DRAWN: MH/MS COVERGLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED. (REFER TO SECTION 1609.1.4, 1609.6.5 AND TABLE 1609.1.4 OF N.Y.S. RESIDENTIAL � r- I.�w�, • �`� SCALE: CONSTRUCTION CODE).THIS IS NOT A SUBSTITUTION FOR DESIGN-PRESSURE.ALL OPENINGS MUST HAVE DESIGN-PRESSURE UPGRADES WHERE APPLICABLE. ': JOB#: � . 74 ALL PANELS MUST BE CUT TO SIZE AND READY TO USE ON ANY NEW WINDOWS AND DOORS.SHUTTERS MUST BE MARKED FOR WHAT OPENING IT IS TO COVER. 1 - 6/18/2025 HARDVARE MUST ACCOMPANY SHUTTERS FOR INSTALLATION. � ���«:rr � � ' >~�;�,, � {y� SHEET NUMBER: °�►� OF' i BF :111 G;�a 35 - © ad REVISIONS: M Re, clue, Z 0 4 Z HORIZONTAL PROJECTION(le DECK) O ZZ COVER v � E O � a Z_ 4"min. Z O F EGRESS WINDOW ' " *VERIFY SIZE PER MFGR Z (PER CODE) 2.5.9 ELECTRIC W D WINDOW SIZE(VIF) o XCUx", WELLCRAFT EGRESS DETAIL NTS 1,INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH 44"max. N MANUFACTURER SPECIFICATIONS" CIO 2,WELL SIZE TO BE MINIMUM 3'X3'CLEARANCE,VERIFY AND UNFINISHED STORAGE EXISTING BASEMENT WINDOW TO BE REMOVED ADJUST PER WINDOW SIZE USED, INSTALL 5/8"TYPE-X FIRE RATED SHEETROCK © 00 ENLARGE OPENING FOR NEW EGRESS OPENING. IM-1 ON WALLS AND CEILLING AT FURNACE AREA 11FRAME 2X8 ACQ ON INSIDE,SEAL OFF AS REQUIRED, 3. ESCAPE WELL TO HAVE COVER AS REQUIRED BY CODE 00 10 INSTALL NEW EGRESS WELL WITH COVER TO CODE 10 I H CIL71 ;N in N 12'.0" -'------ F--� INSTALL SOLID-CORE DOOR ______ _ RE(CREATION ROOM WITH WEATHERSTRIPPING 7.10 CEILING W AND DOOR SWEEP === -- SM10KE AND CO DETECTOR Envelope Assemblies O TO BE INSTALLED TO CODE q Prop. eq*Gross Area or Cavity Cont. U U1. Prop. Req. 0 Assembly Perimeter R Value R-Value Factor/ Factor/ UA UA F-Factor F.-Factor a N INSTALL NEW STAIR WVITH Wall:Solid Concrete or 1003 15.0 0.0 0.078 0.087 77 86 CCC ------ '- NECESSAY RAILING(TY(P) Masonry F1 o O o o I Insulation position: I Interior Insulation -_-,,FL oa TAN --- HOPPERS;Wood Frame 7 0.240 0.320 2 2 SHGC:0,18 EGRESS WINDOW:Wood 12 0,290 0.320 3 4 Frame 37-9" SHGC;0,37 ri - - a U Hiz The%Better or Worse Than Code Index reflects how close to compliance the house Is based on code trade-off rules.It DOES W NOT provide an estimate of energy use or cost relative to a minimum-code home, Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade 5 assembly in the specified climate zone must meet the minimum energy code insulation R-value amd depth requirements. O ¢ }+ Compliance Statement o PROPOSED BASEMENT PLAN The proposed building design described here Is consistent with the building plans,specifications,and other calculations 0 n I n P p 9 9 9 P P n/ ✓' SCALE: 1/4 = 1 -� submitted with the permit application,The proposed building has been designed to meet the 2018 IECC requirements In rW��-11 � O REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. I� U 0 ;:L� U Name-Title Signature Date 0 E m o x ►� EVISIONS: ® Q ® ® 2" ® ® • • ® ® �2" 0 fC 1 . EGRESS WINDOW LOCATION CHANGE v FASTENER TYPE: SPACING: U No.8 WOOD-SCREW - ----_ � ;C ANCHOR WITH BASED WOOD-SCREWS REW 16"DC • •. • 2. WALL 1 N S U LAT l O N CHANGE 0 ' 21n.EMBEDMENT LENGTH � BASED ANCHOR WITH ® ® 1/2 GYPSUM TO BE INSTALLED 9 w II BA.EMBEDMENT 16"oc AT CEILING OF BASEMENT. tin.EMBEDMENT LENGTH BASE.dia.LAGSCREW TAPE AND SPACKLE, 3 COATS,BASED ANCHOR WITH 16"OC tin.EMBEDMENT LENGTH ® ® F ®® SAND, PRIME AND PAINT, ® ® 3/4'A PA PL GRADE YW OD 112'GRA RATED SHEATHING SHEW DEE P PLYWOOD •PQ,yj (ALTERNATMVE:7/16"O.S.B.) ® ®® ® ® 1/2'APA RATED SHEATHING U GRADE PLYWOOD (ALTERNATIVIVE:7/16"O.S.B.) ® O ® ®® 1/2" GYPSUM TO BE INSTALLED INTERIOR FINISHED TRIM ® FASTENER TYPE: SPACING: 2X4 DF#2 OVER 2X4 STUD WALL, AT 16110C AS SELECTED BY OWNER Report Title; POWERS Report Date: 9/17125, 7:24 AM 2 of 2 No.8 WOOD-SCREW STUDS &W� BASED ANCHOR WITH 1o"oc ® R15 INSULATION AS PER RES-CHECK WINDOW SILL tin.EMBEDMENT LENGTH TYPICAL'WINDOW OPENING No.10 WOOD-SCREWS • •• • TAPE AND SPACKLE, 3 COATS, BASED ANCHOR EMBEDMENT WITH 12"Dc SAND PRIME AND PAINT PANEL SWAN EQUAL OR SMALLER tin.EMBEDMENT LENGTH THAN 4 FEET 1/41n.dia.LAGSCREW BASED ANCHOR WITH 16"OC ® Q tin.EMBEDMEM LENGTH I ® •L i • r^W S CONNECTED TYPICAL DOOR OPENING M 2;T LEPLYWDASSEMBUES FASTENER TYPE: SPACING: LAMINATE FLOORING TO BE INSTALLED PANEL SPAN GREATER THAN 4 FEET 2-2X4 DF#2 STUODD No.SWOOD-SCREW AND EQUAL OR SMALLER OR� DBOLTSW1W STEEL ERS BASED ANCHOR WITH 8"Dc OR AS SELECTED BY OWNER, INSTALL � THAN 6 FEET AND NUTS 1'•D"O.C. tin.EMBEDMENT LENGTH NA.ED ANCHORWOOD-SCREWSPER WRITTEN INSTRUCTIONS (TYP) TYPICAL MULTIPLE QPENINGS BASED ANCHOR WITH s^oc PANEL SPAN GREATER THAN 6 FEET 2-EMBEDMENT LENGTH A UAL OR SMALLER 1J4M.dia,LAGSCREW AND EQUAL BASED ANCHOR WITH 16,OC THAN 8 FEET tin.EMBEDMENT LENGTH I^ ttR9Y " WIND-BORNE DEBRIS PROTECTION FOR WOOD STRUCTURAL PANEL p•�„ ��rx�'.r AVVV� AS PER SEC. R301.2.1.2 NYS CODE: PROTECTION OF OPENING WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS WOOD STRUCTURAL PANELS WITH A MINIMUM THICKNESS OF 7/16" S E P 8 AND MAXIMUM PANEL SPAN OF 8 FEET SHALL BE PERMITTED FOR OPENING PROTECTION IN ONE-AND TWO-STORY BUILDINGS.PANELS SHALL BE PRECUT TO 2025 .rm `Q DRAWN; MH/MS COVER GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED,(REFER TO SECTION 1609.1.4,1609.6.5 AND TABLE 1609.1.4 OF N.Y.S,RESIDENTIAL SCALE: CONSTRUCTION CODE).THIS IS NOT A SUBSTITUTION FOR DESIGN-PRESSURE.ALL OPENINGS MUST HAVE DESIGN-PRESSURE UPGRADES WHERE APPLICABLE, ALL PANELS MUST BE CUT TO SIZE AND READY TO USE ON ANY NEW WINDOWS AND DOORS.SHUTTERS MUST BE MARKED FOR WHAT OPENING IT IS TO COVER, f >;,= f,�,tee r. , YF ,p �p` !„� 70B#: HARDWARE MUST ACCOMPANY SHUTTERS FOR INSTALLATION, Tt s!'7 D.r „"4 i��, 9/17/2025 SHEET NUMBER: A- 1 a D �